WorldWideScience
1

'Hair-on-end' skull changes resembling thalassemia caused by marrow expansion in uncorrected complex cyanotic heart disease  

Energy Technology Data Exchange (ETDEWEB)

''Hair-on-end'' skull changes resembling thalassemia were rarely described in the 1950s and 1960s in children with cyanotic congenital heart diseases; these changes were described almost entirely in patients with tetralogy of Fallot or D-transposition of the great arteries. As these lesions have become correctable, the osseous changes, never common, seem now only to exist in a small number of patients with uncorrectable complex cyanotic congenital heart disease who survive in a chronic hypoxic state. We present two cases: a case of marked marrow expansion in the skull of a 5-year-old boy with uncorrectable cyanotic heart disease studied by CT, and a second case of an 8-year-old with tetralogy of Fallot and pulmonary atresia studied by plain skull radiographs. The true incidence of these findings is unknown. (orig.)

2005-07-01

2

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were ...

1996-12-31

3

Extrinsic allergic alveolitis induced by the yeast Debaryomyces hansenii.  

Science.gov (United States)

A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192

2002-11-01

4

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

5

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

6

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

7

Glass Fragment Hazard from Windows Broken by Airblast  

Science.gov (United States)

... MATHEMATICAL PREDICTION, BODIES, SKIN(ANATOMY), SONIC BOOM, BIOPHYSICS, WOUND BALLISTICS, BONE FRACTURES, SKULL. ...

1980-05-30

8

Uncommon bone tumors of the skull: Ewing's sarcoma and Triton's tumor  

International Nuclear Information System (INIS)

Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)

9

Metastatic Ewing's sarcoma to the skull: CNS involvement excluded by MRI  

International Nuclear Information System (INIS)

A case of metastatic Ewing's sarcoma to the skull is presented, demonstrating the superiority of magnetic resonance imaging over other imaging modalities to exclude CNS involvement. Precise delineation of different tumor components in extradural location contained in an intact dural rim together with compressed cortex showing no signs of tumorous involvement constituted an MRI appearance allowing us to exclude tumor outgrowth into the brain. (orig.).

10

Pathogenesis of the Human Opportunistic Pathogen Pseudomonas aeruginosa PA14 in Arabidopsis1  

UK PubMed Central (United Kingdom)

The human opportunistic pathogen Pseudomonas aeruginosa strain PA14 is a multihost pathogen that can infect Arabidopsis. We found that PA14 pathogenesis in Arabidopsis involves the...Full Text Available

2000-12-01

11

3-D brain CT image display for planning of craniofacial operation  

International Nuclear Information System (INIS)

The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).

12

FGF18 is required for normal cell proliferation and differentiation during osteogenesis and chondrogenesis  

UK PubMed Central (United Kingdom)

Fibroblast growth factor (FGF) signaling is involved in skeletal development of the vertebrate. Gain-of-function mutations of FGF receptors (FGFR) cause craniosynostosis, premature fusion of the skull,...Full Text Available

2002-04-01

13

Evidence for modular evolution in a long-tailed pterosaur with a pterodactyloid skull  

UK PubMed Central (United Kingdom)

The fossil record is a unique source of evidence for important evolutionary phenomena such as transitions between major clades. Frustratingly, relevant fossils are still comparatively rare, most transitions...Full Text Available

2010-02-07

14

Diversity among African Pygmies  

UK PubMed Central (United Kingdom)

Although dissimilarities in cranial and post-cranial morphology among African pygmies groups have been recognized, comparative studies on skull morphology usually pull all pygmies together assuming...Full Text Available

15

A New Suchian Archosaur From The Upper Triassic Of North Carolina  

Science.gov (United States)

... rugose ridge along dorsolateral edge of skull; s, scapula; sc, supinator crest; sls, surface for articulation with ... robust supraglenoid buttress of the scapulocoracoid; immediately narrowing scapula po...

17

Clinical application of dual energy subtraction in direct digital radiography of chest  

International Nuclear Information System (INIS)

Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films showed a higher diagnostic accuracy in the detection of bony cage ...

2009-02-01

18

Fusion expression of pedA gene to obtain biologically active pediocin PA-1 in Escherichia coli *  

UK PubMed Central (United Kingdom)

Two heterologous expression systems using thioredoxin (trxA) as a gene fusion part in Escherichia coli were developed to produce recombinant pediocin PA-1. Pediocin...Full Text Available

2011-01-01

21

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

22

Periodicity of the Phanerozoic magmatism in Mongolia from potassium-argon data  

International Nuclear Information System (INIS)

An attempt was made to set the main potassium-argon (PA) boundaries in magmatism development in the territory of Mongolia. Results were correlated with the known concepts about periodicity of magmatism. Possibility of using PA analysis for separation of magmatic rocks was evaluated. Reliable correlation of significant PA boundaries of magmatism with geological periodization of tectonomagmatic events in Mesozoic era and Late Paleozoic era was established.

1989-01-01

23

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

24

Clinical application of FCR for the portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-08-01

25

Clinical application of FCR for the portable chest radiographs in ICU  

International Nuclear Information System (INIS)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-01-01

26

RADIONUCLIDE DATA PACKAGE FOR PERFORMANCE ASSESSMENT CALCULATIONS RELATED TO THE E-AREA LOW-LEVEL WASTE FACILITY AT THE SAVANNAH RIVER SITE.  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site disposes of low-level radioactive waste within on-site engineered disposal facilities. The Savannah River Site must demonstrate that these disposals meet the requirements of DOE Order 435 . 1 through a process known as performance assessment (PA). The objective of this document is to provide the radionuclide -specific data needed for the PA calculations . This work is part of an on-going program to periodically review and update existing PA work as new data becomes available. Revision of the E -Area Low-Level Waste Facility PA is currently underway. The number of radionuclides selected to undergo detailed analysis in the PA is determined by a screening process. The basis of this process is described. Radionuclide-specific data for half-lives, decay modes, daughters, dose conversion factors and groundwater concentration limits are presented with source ...

2007-03-20

27

Primary and multisensory cortical activity is correlated with audiovisual percepts  

British Library Electronic Table of Contents (United Kingdom)

Incongruent auditory and visual stimuli can elicit audiovisual illusions such as the McGurk effect where visual /ka/ and auditory /pa/ fuse into another percept such as/ta/. In the present study, human brain activity was measured with adaptation functional magnetic resonance imaging to investigate which brain areas support such audiovisual illusions. Subjects viewed trains of four movies beginning with three congruent /pa/ stimuli to induce adaptation. The fourth stimulus could be (i) another congruent /pa/, (ii) a congruent /ka/, (iii) an incongruent stimulus that evokes the McGurk effect in susceptible individuals (lips /ka/ voice /pa/), or (iv) the converse combination that does not cause the McGurk effect (lips /pa/ voice/ ka/). This paradigm was predicted to show increased release fro...

2010-01-01

28

Radiographic features of Ewing's sarcoma of the bones of the hands and feet  

International Nuclear Information System (INIS)

The radiographic features of Ewing's sarcoma of the bones of the hands and feet are reviewed utilizing cases obtained from the Mayo Clinic patient files and the consultation files of Drs. D.C. Dahlin and K.K. Unni. This series consists of a total of 43 cases of pathologically proven Ewing's sarcoma involving the small bones of the hands and feet. The classic radiographic features of Ewing's sarcoma in the long bones, including lytic, permeative destruction, aggressive periosteal reaction, cortical violation, and a soft tissue mass, are also seen in the bones of the hands and feet, with similar frequency. These classic features are most commonly present in lesions affecting the short tubular bones. Lesions affecting the tarsal bones more often demonstrate atypical radiographic features. These atypical radiographic appearances may play a role in the reported delay in diagnosis of Ewing's sarcoma within ...

2001-03-01

29

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

30

MR findings of primary Ewing's sarcoma of greater wing of sphenoid  

International Nuclear Information System (INIS)

Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd

2002-12-01

31

Diagnostic imaging of the acutely injured patient  

Energy Technology Data Exchange (ETDEWEB)

This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.

1985-01-01

32

CT scan findings in cerebral paragonimiasis  

International Nuclear Information System (INIS)

Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).

1982-01-01

33

Longitudinal changes in extended roles in radiography  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating ...

2002-11-01

34

Isolation and amino acid sequence of a short-chain neurotoxin from an Australian elapid snake, Pseudechis australis.  

Science.gov (United States)

A short-chain neurotoxin Pseudechis australis a (toxin Pa a) was isolated from the venom of an Australian elapid snake Pseudechis australis (king brown snake) by sequential chromatography on CM-cellulose, Sephadex G-50 and CM-cellulose columns. Toxin Pa a has an LD50 (intravenous) value of 76 micrograms/kg body wt. in mice and consists of 62 amino acid residues. The amino acid sequence of Pa a shows considerable homology with those of short-chain neurotoxins of elapid snakes, especially of true sea snakes. PMID:4091794

1985-12-01

35

The carbon fiber surface treatment and addition of PA6 on tensile properties of ABS composites  

British Library Electronic Table of Contents (United Kingdom)

In this study acrylonitrile-butadiene-styrene (ABS) terpolymer was reinforced with HNO3-treated short carbon fibers (HCFs). The effects of HCF concentration on the tensile properties of the composites were examined. Increasing the HCF concentration in the ABS matrix from 10 wt% to 30 wt% resulted in improved tensile strength and tensile modulus. To obtain a strong interaction at the interface, polyamide-6 (PA6) at varying concentrations was introduced into the ABS/10 wt% HCF composite. The incorporation and increasing amount of PA6 in the composites increased tensile properties of the ABS/PA6/HCF systems due to the improved adhesion at the interface, which was confirmed by the ratio of tensile strength as an adhesion parameter. These results were also supported by scanning electron microgr...

2011-01-01

36

The Shock and Vibration Bulletin. Part 1. Welcome, Keynote ...  

Science.gov (United States)

... E. 3. Krasnicki, Lord Corporation, Erie, PA EFFECT OF AIR CAVITY ON THE VIBRATION ANALYSIS OF LOADED DRUMS S. Do. ...

1984-06-01

37
38

NASA - NASA Selects Pennsylvania Firm to Build Liquid Nitrogen Plant  

Science.gov (United States)

Sep 21, 2006 ... NASA has selected Air Products and Chemicals, Inc., Allentown, Pa., to design, furnish and install a plant to produce liquid nitrogen for ...

39

Hydrogen adsorption by activated charcoal at low pressure and 20/sup 0/K  

Energy Technology Data Exchange (ETDEWEB)

Measurements of hydrogen adsorption capacity by activated charcoal has been made at a pressure minus than 10/sup -4/ Pa and at 18 K.

1984-04-01

40

Design and Evaluation of a Reinforced Advanced-Grid ...  

Science.gov (United States)

... kg/m3 density. The Rohacell foam displayed an average ultimate compressive strength of 1546 kPa. The maximum load ...

2011-05-14

42

BAM: Diarrheagenic Escherichia coli  

Science.gov (United States)

... Confirm isolates that appear as typical E. coli on L-EMB and are X-gal (+), MUG (+) or (-) and ... Hill, WE, KC Jinneman, PA Trost, JL Bryant, J. Bond and MM Wekell ...

43

Opportunistic esophagitis in AIDS: Radiographic diagnosis  

International Nuclear Information System (INIS)

Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention.

44

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-12-01

45

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

International Nuclear Information System (INIS)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-01-01

46

Cost Sensitivity Analysis for Radiology Department Planning  

UK PubMed Central (United Kingdom)

Two complementary computer programs have been developed for forecasting the demands and evaluating the costs of proposed radiographic facilities. The models are employed here in analyses of the sensitivity...Full Text Available

1971-01-01

47

Clinical evaluations of intra-arterial subtraction angiography using Fuji computed radiography  

International Nuclear Information System (INIS)

Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).

1985-01-01

48

Visualization of the salivary glands. CT and MRI  

International Nuclear Information System (INIS)

For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors better than palpation ...

49

Irradiation by carbon ions?: why? How?; Irradiation par ions carbone: pourquoi? Comment?  

Energy Technology Data Exchange (ETDEWEB)

The interest of irradiation by carbon ions is in the fact that the carbon ions leave all their energy to a determined depth. ( phenomenon known under the name of Bragg peak)This high diffusion in tissue gives an RBE particularly high. The indications of this therapy are chordomas, and chondrosarcomas of the skull base, some cyst adenoid carcinomas, pulmonary cancer, sarcomas, hepato carcinomas, melanomas. In the light of results in term of efficiency, the place of irradiation by carbon ions should widen. (N.C.)

2006-11-15

50

Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography  

International Nuclear Information System (INIS)

A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

1994-04-05

51

Polyamide/Polystyrene Blend Compatibilisation by Montmorillonite Nanoclay and its Effect on Macroporosity of Gas Diffusion Layers for Proton Exchange Membrane Fuel Cells  

British Library Electronic Table of Contents (United Kingdom)

This work deals with a new route to modify polymer blend morphology in order to improve the porosity of gas diffusion layers (GDLs) for proton exchange membrane fuel cells (PEMFCs). First, electrically conductive polymer-based blends were carefully formulated using a twin-screw extrusion process. Blend electrical conductivity was ensured by the addition of high specific surface area carbon black and synthetic graphite flakes. Final GDL porosity, in particular its macroporosity, was generated by melt blending polyamide 11 (PA11) matrix with polystyrene (PS) followed by PS extraction with tetrahydrofuran (THF) solvent at room temperature. In order to improve GDL porosity by the optimisation of PS dispersion in the PA11 matrix, PA11/PS blends were compatibilised by the addition of 2 wt.-% of ...

2007-01-01

52

Adsorption of Db and its homologues Nb and Ta, and the pseudo-homologue Pa on anion-exchange resin in HF solution  

Energy Technology Data Exchange (ETDEWEB)

Anion-exchange chromatography of element 105, dubnium (Db), produced in the {sup 248}Cm({sup 19}F, 5n){sup 262}Db reaction is investigated together with the homologues Nb and Ta, and the pseudo-homologue Pa in 13.9 M hydrofluoric acid (HF) solution. The distribution coefficient (K{sub d}) of Db on an anion-exchange resin is successfully determined by running cycles of 1702 chromatographic column separations. The result clearly indicates that the adsorption of Db on the resin is significantly different from that of the homologues and that the adsorption of anionic fluoro complexes of these elements decreases in the sequence of Ta{approx}Nb>Db{>=}Pa. (orig.)

2009-07-01

53

Adsorption of Db and its homologues Nb and Ta, and the pseudo-homologue Pa on anion-exchange resin in HF solution  

International Nuclear Information System (INIS)

Anion-exchange chromatography of element 105, dubnium (Db), produced in the "2"4"8Cm("1"9F, 5n)"2"6"2Db reaction is investigated together with the homologues Nb and Ta, and the pseudo-homologue Pa in 13.9 M hydrofluoric acid (HF) solution. The distribution coefficient (K_d) of Db on an anion-exchange resin is successfully determined by running cycles of 1702 chromatographic column separations. The result clearly indicates that the adsorption of Db on the resin is significantly different from that of the homologues and that the adsorption of anionic fluoro complexes of these elements decreases in the sequence of Ta#approx#Nb>Db#>=#Pa. (orig.)

54

Terminal phalangeal accessory ossification center of the thumb: an additional radiographic finding in Larsen syndrome  

International Nuclear Information System (INIS)

Larsen syndrome is an autosomal-dominant disorder characterized by multiple joint dislocations, vertebral anomalies and dysmorphic facies. Both autosomal-dominant and autosomal-recessive forms of the disorder have been proposed. Individuals with autosomal-dominant Larsen syndrome have characteristic ''cylindrical-shape'' thumbs caused by broad, shortened phalanges. Autosomal-dominant Larsen syndrome results from heterozygosity for mutations in filamin B, a cytoskeletal protein involved in multicellular processes. We report here a patient with a duplicated or accessory distal thumb phalanx and multiple large joint dislocations who was shown to be heterozygous for a filamin B mutation predicting the amino acid substitution G1691S. This adds a new radiographic finding, duplicated or accessory distal phalanx, to the radiographic abnormalities seen in this rare dominant disorder. (orig.)

2006-09-01

55

Plain radiographic predictors of survival in treated Ewing's sarcoma  

International Nuclear Information System (INIS)

We analyzed 16 radiographic features of primary Ewing's sarcoma in 342 patients from the IESS 7299 (Intergroup Ewing's Sarcoma Study) for prognostic significance. Of these, 3 features demonstrated a statistically significant relationship to survival: maximal tumor dimension, tumor location, and an appearance of honeycombing within the lesion. Those individuals with primary lesions centered in the pelvis, femur, or humerus had a worse survival rate than those with lesions centered elsewhere. Similarly, we observed an inverse relationship between the greatest dimension of the osseous portion of the lesion and survival. The radiographic finding of honeycombing also showed a statistical association with improved survival. However, this feature was observed infrequently, and its significance should be assessed further. Otherwise, no other feature that we analyzed showed any relationship to patient prognosis. (orig.).

56

Long-term changes in graft height after maxillary sinus floor elevation with different grafting materials: radiographic evaluation with a minimum follow-up of 4.5 years  

British Library Electronic Table of Contents (United Kingdom)

Abstract Objective: To compare the vertical dimensional changes with regard to graft height in a long-term follow-up in patients treated with two different grafting materials used in maxillary sinus floor elevation procedures. Material and methods: Twenty consecutive patients were included. One group was grafted with autogenous bone from the mandible (chin area), and the other group was augmented with a 100%b-tricalcium phosphate (b-TCP). During a 4- to 5-year period, in each patient, at least five panoramic radiographs were made. These panoramic radiographs were used for morphometric measurements, at three different locations. The three locations were the first bone to implant contact at the distal side of the second most posterior implant (L1), halfway between this implant and the most p...

2009-01-01

57

Incidence and prognostic significance of radiological abnormalities in soft tissue injuries to the cervical spine  

Energy Technology Data Exchange (ETDEWEB)

The radiographs and initial clinical findings of 73 patients who had sustained trauma to the cervical spine without bony injury in vehicle collisions were reviewed. The patients were also re-examined clinically two years after the injury. Forty eight (65.8%) had abnormal radiographs at presentation - prevertebral soft tissue swelling in 15 (20.6%), degenerative changes in 15 (20.6%), and an angular deformity between two adjacent vertebral bodies in 27 (37.0%). The exact mode of inury is not associated with any specific radiographic appearance except that ''roll overs'' and side collisions are more likely to cause angulation in the cervical spine. (orig./GDG).

1988-10-01

58

Computed tomography of the acetabular fractures  

Energy Technology Data Exchange (ETDEWEB)

In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.

1986-04-15

59

planet BAN KI-MOON  

Wastenet

CLIMATE CHANGE Copenhagen: seal the deal ...2 OUR PLANET SEAL THE DEAL UNEP promotes environmentally sound practices globally and in its own activities. ...PaGE 30OUR PLANET SEAL THE DEAL 3

60

The Relationships between Weather-Related Factors and Daily Outdoor Physical Activity Counts on an Urban Greenway  

UK PubMed Central (United Kingdom)

The purpose of this study was to examine relationships between weather and outdoor physical activity (PA). An online weather source was used to obtain daily max temperature [DMT], precipitation, and...Full Text Available

2011-02-01

61

The Pseudomonas aeruginosa PA01 Gene Collection  

UK PubMed Central (United Kingdom)

Pseudomonas aeruginosa, a common inhabitant of soil and water, is an opportunistic pathogen of growing clinical relevance. Its genome, one of the largest among bacteria [5570 open reading...Full Text Available

2004-10-01

62

Simulation of solid molecular hydrogen - a new twist to an old problem  

British Library Electronic Table of Contents (United Kingdom)

Solid molecular orthohydrogen exhibits orientational order at low temperatures. The orthohydrogen molecules, which are quadrupoles, order in the Pa3 structure. We have simulated this ordering, and explored the behaviour under dilution by spherical parahydrogen molecules.

2010-01-01

63

SHIPBOARD RADIOLOGICAL - COUNTERMEASURE ...  

Science.gov (United States)

... H1+80 Remaining H +82 Remaining H+56 IlemaJntng ,H+77 Remaining. Aa pct c/m pct mr/hr pet mr/hr pet ... mr/hr avg. pct c/rnh pt pa pct ...

1959-01-30

64

Rhabdomere biogenesis in Drosophila photoreceptors is acutely sensitive to phosphatidic acid levels  

UK PubMed Central (United Kingdom)

Phosphatidic acid (PA) is postulated to have both structural and signaling functions during membrane dynamics in animal cells. In this study, we show that before a critical time period during rhabdomere...Full Text Available

2009-04-06

65

Pa0148 from Pseudomonas aeruginosa Catalyzes the Deamination of Adenine.  

Science.gov (United States)

Four proteins from NCBI cog1816, previously annotated as adenosine deaminases, have been subjected to structural and functional characterization. Pa0148 (Pseudomonas aeruginosa PAO1), AAur1117 (Arthrobacter aurescens TC1), Sgx9403e, and Sgx9403g have been purified and their substrate profiles determined. Adenosine is not a substrate for any of these enzymes. All of these proteins will deaminate adenine to produce hypoxanthine with k(cat)/K(m) values that exceed 10(5) M(-1) s(-1). These enzymes will also accept 6-chloropurine, 6-methoxypurine, N-6-methyladenine, and 2,6-diaminopurine as alternate substrates. X-ray structures of Pa0148 and AAur1117 have been determined and reveal nearly identical distorted (?/?)(8) barrels with a single zinc ion that is characteristic of members of the amidohydrolase superfamily. Structures of Pa0148 with adenine, 6-chloropurine, and hypoxanthine were also determined, thereby permitting ...

2011-07-06

66

K Kiosk - NIH Extramural Training: Information about NIH Career...  

Science.gov (United States)

Established Investigators (K18) (PAR-09-090) NIH: Career Enhancement Award for Stem Cell Research (K18) (PA-09-110) NIDCD: NIDCD Research Career Enhancement Award for Established...

2011-10-01

67

Institute of Plasma Physics, Academy of Sciences of the Czech Republic  

International Nuclear Information System (INIS)

The major activities of the various Institute's departments are highlighted. The following departments are included: (i) Tokamak; (ii) Pulse plasma systems; (iii) Thermal plasma; (iv) Materials engineering; (v) Laser plasma; and (vi) Optical diagnosis. (P.A.)

68

Bench-to-bedside review: Carbon dioxide  

UK PubMed Central (United Kingdom)

Carbon dioxide is a waste product of aerobic cellular respiration in all aerobic life forms. PaCO2 represents the balance between the carbon dioxide produced and that eliminated. Hypocapnia...Full Text Available

2010-01-01

69

Aging and the Social Cognitive Determinants of Physical Activity Behavior and Behavior Change: Evidence from the Guide to Health Trial  

UK PubMed Central (United Kingdom)

Part one of this study investigated the effect of aging on social-cognitive characteristics related to physical activity (PA) among adults in the baseline phase of a health promotion...Full Text Available

70

A participatory parent-focused intervention promoting physical activity in preschools: design of a cluster-randomized trial  

UK PubMed Central (United Kingdom)

BackgroundWith rates of childhood obesity increasing, physical activity (PA) promotion especially in young children has assumed greater importance. Given the limited effectiveness...Full Text Available

71

Spinous process palpation using the scapular tip as a landmark vs a radiographic criterion standard  

UK PubMed Central (United Kingdom)

AbstractObjectiveThis study aimed at determining the standing spinal landmark that corresponds to the inferior tip of the scapula and determining the accuracy of experienced...Full Text Available

2007-01-01

72

Radiographic monitoring of incidental abdominal aortic aneurysms: a retrospective population-based cohort study  

UK PubMed Central (United Kingdom)

BackgroundAn abdominal aortic aneurysm (AAA) that is identified when the abdomen is imaged for some other reason is known as an incidental AAA. No population-based studies have...Full Text Available

73

Radiographic experience with power transmission equipment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.

1980-01-01

74

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the ...

2009-10-15

75

Positional Stretching of the Coracohumeral Ligament on a Patient with Adhesive Capsulitis: A Case Report  

UK PubMed Central (United Kingdom)

Idiopathic frozen shoulder is a common medical diagnosis for patients seeking physical therapy. Radiographic and surgical evidence exists that describes the coracohumeral ligament (CHL) as a major contributor...Full Text Available

2009-01-01

76

Late metastasis from neuroblastoma mimicking Ewing's sarcoma  

International Nuclear Information System (INIS)

The case of an unusual late metastasis of neuroblastoma to the calcaneum, appearing as a sole recurrence 9 years after surgery, is reported. The radiographic features of the osseous lesion were very suggestive of primary bone malignancy, Ewing's sarcoma as the first option, with extraosseous spread to the soft tissues. (orig.).

77

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

International Nuclear Information System (INIS)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both ...

1999-09-01

78

Ewing's sarcoma presenting as a solitary cyst  

International Nuclear Information System (INIS)

This case describes a 10-year-old girl who developed a Ewing's sarcoma in her proximal fibula. The radiologic features mimicked those of a unicameral bone cyst. The presence of pain and the atypical location led to a prompt biopsy and the correct diagnosis. The mechanism of this unusual radiographic presentation is discussed. (orig.)

2006-07-01

79

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...

1991-11-01

80

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...

1991-01-01

81

Changes in inflammatory mediators in experimental periodontitis in the rhesus monkey.  

UK PubMed Central (United Kingdom)

Ligature-induced periodontitis was monitored for 6 months in eight Macaca mulatta monkeys to examine clinical status, radiographic bone level, and crevicular fluid (CF) levels of prostaglandin E2 (PGE2),...Full Text Available

1993-04-01

82

Case series of maxillary sinus augmentation with biphasic calcium phosphate: a clinical and radiographic study  

UK PubMed Central (United Kingdom)

PurposeThe aim of this study was to evaluate 3.5 years-cumulative survival rate of implants placed on augmented sinus using Osteon, a bone graft material, and to assess the height...Full Text Available

2011-04-01

83

Candidate salivary biomarkers associated with alveolar bone loss: cross-sectional and in vitro studies  

UK PubMed Central (United Kingdom)

This cross-sectional study evaluated the association between radiographic evidence of alveolar bone loss and the concentration of host-derived bone resorptive factors (interleukin-1 beta, tumor...Full Text Available

2007-03-01

84

Bladder outlet obstruction in a 6-month-old alpaca secondary to pelvic displacement of the urinary bladder  

UK PubMed Central (United Kingdom)

AbstractA 6-month-old female alpaca was presented for stranguria. Based on the history, physical examination findings, and radiographic studies, the alpaca was diagnosed with bladder...Full Text Available

2005-03-01

85

A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate  

UK PubMed Central (United Kingdom)

BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available

2010-11-01

86

Temporal effects in the growth of networks  

CERN Document Server

We show that to explain the growth of the citation network by preferential attachment (PA), one has to accept that individual nodes exhibit heterogeneous fitness values that decay with time. While previous PA-based models assumed either heterogeneity or decay in isolation, we propose a simple analytically treatable model that combines these two factors. Depending on the input assumptions, the resulting degree distribution shows an exponential, log-normal or power-law decay, which makes the model an apt candidate for modeling a wide range of real systems.

2011-01-01

87

Production of cumulative pions and kaons  

International Nuclear Information System (INIS)

#pi#"#+-# and K"#+-# cumulative production in pA #-># #pi#"#+-#+x and pA #-># K"#+-#+x reactions at 10.14 GeV proton beam energy on nuclei (Be-Ta) was invesigated. Measurements were conducted using FAS-1 focusing hadron spectrometer. Invariant cross sections of #pi#"#+-# and K"#+-# cumulative production, values of ratio of this cross sections, dependences of production cross sections for pions and kaons on cumulative number and mass number of nucleus target, as well as on transverse momentum are measured. Difference of cumulative meson spectra occurring in different nuclei fragmentation is discussed in terms of flucton model. 17 refs.; 14 figs.

1988-06-14

88

Investigation of chloro, sulfato and oxalato-complexes of protactinium (V) by solvent extraction technique  

International Nuclear Information System (INIS)

The stability constant values of Pa(V) with some complexing ligands (chloride, sulfate and oxalate) are graphically determined using solvent extraction data. The organic phase was at constant composition of HTTA in benzene while the aqueous phase was held at constant hydrogen ion concentration and ionic strength of 3. The curve-fitting method was adopted throughout this investigation, giving the following values. The stability constants obtained are used to calculate the distribution of the different Pa (V) species in the corresponding aqueous phase (expressed in mole fraction) as a function of ligand ion concentration.

89

A research agenda to examine the efficacy and relevance of the Transtheoretical Model for physical activity behavior  

British Library Electronic Table of Contents (United Kingdom)

Regular physical activity (PA) decreases the risk of several chronic diseases including some cancers, type II diabetes, obesity, and cardiovascular disease; however, the majority of US adults are not meeting the recommended levels to experience these benefits. To address this public health concern, the underlying mechanisms for behavior change need to be understood, translated and disseminated into appropriately tailored interventions. The Transtheoretical Model (TTM) provides a framework for both the conceptualization and the measurement of behavior change, as well as facilitating promotion strategies that are individualized and easily adapted. The purpose of this manuscript is to present the constructs of the TTM as they relate to PA behavior change. We begin with a brief synopsis of rec...

2011-01-01

90

The morphology and systematics of Mammalodon colliveri (Cetacea: Mysticeti), a toothed mysticete from the Oligocene of Australia  

British Library Electronic Table of Contents (United Kingdom)

Mammalodon colliveri is an unusual toothed archaic mysticete (Cetacea) from the Upper Oligocene Jan Juc Formation of south-east Australia. The morphology of the holotype skull and postcrania are described in detail. Superimposed on the generally plesiomorphic archaeocete-like morphology of Mammalodon are subtle mysticete synapomorphies. Derived features of Mammalodon include a short and bluntly rounded rostrum, reduced premaxillae, and anterodorsally directed orbits. Within Mysticeti, this suite of features is unique. The aberrant rostral morphology of Mammalodon suggests specialization for suction feeding. Janjucetus hunderi is placed in an expanded family Mammalodontidae. Phylogenetic analysis corroborates the monophyly of Basilosauridae, Neoceti, Odontoceti, and Mysticeti, and yields a ...

2010-01-01

91

Subdural effusions in children under two years. Clinical and computer-tomographical data  

Energy Technology Data Exchange (ETDEWEB)

We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 clinical symptoms highly diagnostic of subdural effusions.

1980-05-01

92

Histologie et mode de croissance des premaxillaires hyperplasiques du Ziphiidae fossile Aporotus recurvirostris (Mammalia, Cetacea, Odontoceti)  

British Library Electronic Table of Contents (United Kingdom)

Beaked whales (Ziphiidae) often show highly specialized features, involving bone morphology or structure, in the rostral region of their skulls. Previous studies revealed an extremely derived and peculiar histological structure in the rostrum of the extant Mesoplodon densirostris. In order to assess if this structure is a general feature of ziphiids, the swollen premaxillae of Aporotus recurvirostris, a Miocene species from the North Sea, were studied histologically. These bones are pachyostotic and strongly osteosclerotic. However, their structural organization is entirely different from that of M. densirostris rostrum: they are basically made of a non-remodeled, laminar tissue that was cyclically deposited by the periosteum. As compared to the generalized structure of the premaxillae of ...

2011-01-01

93

Computational mouse atlases and their application to automatic assessment of craniofacial dysmorphology caused by the Crouzon mutation Fgfr2C342Y  

British Library Electronic Table of Contents (United Kingdom)

Abstract Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landma...

2007-01-01

94

Intermediate form of osteopetrosis with recessive inheritance  

International Nuclear Information System (INIS)

The clinical and radiographic features of the intermediate form of osteopetrosis in two sibs are presented in which the disorder appears to have been inherited as a recessive trait. Although this form of osteopetrosis has been poorly delineated, its recognition is practically important in order to give an accurate prognosis. This paper also presents an unusual complication of bilateral avascular necrosis of the femoral head in the younger sib. Radiographic changes of the femoral heads suggest those of Legg-Calve-Perthes disease, though the possibility of avascular necrosis following unrecognized femoral neck fracture is not completely excluded. (orig.).

95

Dextranomer/hyaluronic acid copolymer (Deflux) implants mimicking distal ureteral calculi on CT  

Energy Technology Data Exchange (ETDEWEB)

Periureteral or subtrigonal injection of dextranomer/hyaluronic acid (Dx/HA) copolymer (Deflux, Q-Med, Uppsala, Sweden) is an increasingly common endoscopic treatment for vesicoureteral reflux. We report a confusing radiographic finding of bilateral calcified Dx/HA injections initially thought to represent bilateral distal ureteral stones in a boy who presented with intermittent periumbilical pain. Urologists, radiologists, and emergency room physicians should be aware of the potential for calcification of ureteral implants of Dx/HA, and of the potentially confusing radiographic images that may result. (orig.)

2008-01-15

96

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

97

Immunological correlates for protection against intranasal challenge of Bacillus anthracis spores conferred by a protective antigen-based vaccine in rabbits.  

Science.gov (United States)

Correlates between immunological parameters and protection against Bacillus anthracis infection in animals vaccinated with protective antigen (PA)-based vaccines could provide surrogate markers to evaluate the putative protective efficiency of immunization in humans. In previous studies we demonstrated that neutralizing antibody levels serve as correlates for protection in guinea pigs (S. Reuveny et al., Infect. Immun. 69:2888-2893, 2001; H. Marcus et al., Infect. Immun. 72:3471-3477, 2004). In this study we evaluated similar correlates for protection by active and passive immunization of New Zealand White rabbits. Full immunization and partial immunization were achieved by single and multiple injections of standard and diluted doses of a PA-based vaccine. Passive immunization was carried out by injection of immune sera from rabbits vaccinated with PA-based vaccine prior to challenge with B. anthracis spores. Immunized ...

2006-01-01

98

CO_2 reactivity and heterogeneity of cerebral blood flow in ischemic, border zone, and normal cortex  

International Nuclear Information System (INIS)

Regional arterial CO2 tension (PaCO2) reactivity of cerebral blood flow (CBF) and the effect of PaCO2 on the spatial and temporal heterogeneity of CBF were investigated by using autoradiographically determined CBF in the rat middle cerebral artery occlusion model after a 2-h period under pentobarbital anesthesia to clarify the relation between PaCO2 reactivity, CBF heterogeneity, and the temporal cycling of CBF. PaCO2 was adjusted to one of four levels. CBF was determined in four cortical areas and white matter using the tissue fractionation of [14C]iodoantipyrine [( 14C]IAP) in combination with vessel mapping using in vivo 4% thioflavine S. Specific PaCO2 reactivity and CBF were normal in the nonischemic cortex, normal, although slightly depressed, in the border zone far from the ischemic core area, and depressed in the border zone adjacent to the ischemic core area (P less than ...

99

Visual search behaviour in skeletal radiographs: a cross-speciality study  

Energy Technology Data Exchange (ETDEWEB)

Aim: To determine whether experience improves the consistency of visual search behaviour in fracture identification in plain radiographs, and the effect of specialization. Material and methods: Twenty-five observers consisting of consultant radiologists, consultant orthopaedic surgeons, orthopaedic specialist registrars, orthopaedic senior house officers, and accident and emergency senior house officers examined 33 skeletal radiographs (shoulder, hand, and knee). Eye movement data were collected using a Tobii 1750 eye tracker with levels of diagnostic confidence collected simultaneously. Kullback-Leibler (KL) divergence and Gaussian mixture model fitting of fixation distance-to-fracture were used to calculate the consistency and the relationship between discovery and reflective visual search phases among different observer groups. Results: Total time spent studying the radiograph was not significantly different between the ...

2007-11-15

100

Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen  

Energy Technology Data Exchange (ETDEWEB)

Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den Okzipitalkondylen, die ...

1995-01-01

101

A clinical assessment of the relationship between bone scintigraphy and serum biochemical markers in hemodialysis patients  

International Nuclear Information System (INIS)

Renal osteodystrophy is a metabolic bone disease and a common complication of end-stage chronic renal failure and maintenance dialysis treatment. In this study, we examined the correlation between quantifying bone scintigraphy and serum biochemical markers in hemodialysis patients. Bone scintigraphy with technetium-99m-hydroxy-methylene-diphosphonate ("9"9"mTc-HMDP) was performed on 28 patients on maintenance hemodialysis. Bone scintigraphy was performed using a standard protocol and was quantified by setting regions of interest (ROIs) over selected regions. The bone-to-soft-tissue ratio (B/ST ratio) at each region was calculated in all patients. The B/ST ratios were then compared with serum biochemical markers. The B/ST ratio for the skull correlated well with serum bone-specific alkaline phosphatase (BAP) (r=0.735, p<0.001), serum deoxypyridinoline (DPD) (r=0.806, p<0.001) and intact parathyroid hormone (intact PTH) (r=0.701, p<0.001). The B/ST ratio for ...

2004-09-01

102

Relationship between hemodynamic response to exercise and distribution of pulmonary perfusion in mitral stenosis  

Energy Technology Data Exchange (ETDEWEB)

Relationship between hemodynamic response to exercise and distribution of pulmonary perfusion was studied in 71 patients with mitral stenosis. Distribution was estimated by using computerized Tc-99m-MAA perfusion images (digital perfusion images; DPI). DPI were composed of isocount areas. Various types of DPI were obtained and were classified to 6 grades (G) according to patterns of 100 - 70% isocount area in right anterior DPI, i.e. G-0 (normal), G-1 (increase of perfusion at upper zone), G-2 (uniform distribution), G-3 (disappearance of basal hyperperfusion area), G-4 (apical hyperperfusion area) and G-5 (decrease of perfusion at lower zone). Patients were devided to 4 groups according to grade. At rest there were no marked hemodynamic differences between groups (n = 71, mean pulmonary artery pressure (mPA); 24.8 +- 11.0 mmHg, cardiac index (CI); 2.7 +- 0.81 lmM/sup 2/), however hemodynamic parameter during exercise showed marked differences, i.e. G-0 (n = 13, ...

1987-11-01

103

CT in the study of thoracic-pulmonary complications after liver transplantation  

International Nuclear Information System (INIS)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the ...

2000-12-01

104

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the ...

1986-01-01

105

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative ...

1986-01-01

106

Technology application for processing highly viscous liquid in polymer plants  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces recent instances of polymerizers for highly viscous liquid needed in the field of synthetic resin and synthetic fiber. A horizontal twin-shaft type polymerizer has two horizontally rotating shafts with stirring blades of spectacle-shaped type, which are arranged at a 90 [degree] phase difference. As they rotate, they scrape highly viscous liquid sticking to the surface inside the polymerizer and on the rotating shafts. This polymerizer is capable of processing highly viscous liquid up to about 2000 Pa[center dot]s. A lattice-type twisting blade polymerizer is a vertical-type reactor and features a special stirring blade capable of stirring highly viscous liquid up to 5000 Pa[center dot]s This polymerizer has no central rotating shaft so that highly viscous liquid does not stick on it. A sloped blade-type thin-film evaporator has spiral blades in the longitudinal direction of the rotor. Process liquid pushed to the inner ...

1993-01-01

107

Polyamide/Polystyrene blend compatibilisation by montmorillonite nanoclay and its effect on macroporosity of gas diffusion layers for proton exchange membrane fuel cells  

Energy Technology Data Exchange (ETDEWEB)

This work deals with a new route to modify polymer blend morphology in order to improve the porosity of gas diffusion layers (GDLs) for proton exchange membrane fuel cells (PEMFCs). First, electrically conductive polymer-based blends were carefully formulated using a twin-screw extrusion process. Blend electrical conductivity was ensured by the addition of high specific surface area carbon black and synthetic graphite flakes. Final GDL porosity, in particular its macroporosity, was generated by melt blending polyamide 11 (PA11) matrix with polystyrene (PS) followed by PS extraction with tetrahydrofuran (THF) solvent at room temperature. In order to improve GDL porosity by the optimisation of PS dispersion in the PA11 matrix, PA11/PS blends were compatibilised by the addition of 2 wt.-% of clay. It was observed that both macroporosity and pore size distribution were beneficially modified after blend compatibilisation. Final ...

2007-12-15

108

Extended Gas in Seyfert Galaxies Near Infrared Observations of NGC 2110 and Circinus  

CERN Document Server

We present results of near--IR long-slit spectroscopy in the J and K bands of the Seyfert 2 galaxies NGC 2110 and Circinus, investigating the gaseous distribution, excitation, reddening and kinematics. In NGC 2110, the emission line ratio [FeII]/Pa beta increases towards the nucleus (to ~ 7). The nuclear [Fe II]1.257 (microns) and Pa beta lines are broader (FWHM ~ 500 km/s) than the H2 (2.121) line (FWHM ~ 300 km/s). Both these results suggest that shocks, driven by the radio jet, are an important source of excitation of [Fe II]. The H2 excitation appears to be dominated by X-rays from the nucleus. In Circinus, both [FeII]/Pa beta and H2/Br gamma decrease from ~ 2 at 4 arcsec from the nucleus to nuclear values of ~ 0.6 and ~ 1, respectively, suggesting that the starburst dominates the nuclear excitation, while the AGN dominates the excitation further out (r > 2 arcsec). For both galaxies, the gaseous kinematics are ...

1998-01-01

109

Elastic properties of potential superhard phases of RuO_2  

International Nuclear Information System (INIS)

First-principles plane-wave pseudopotential and full-potential linearized-augmented plane-wave methods have been used to study the elastic and electronic properties of several potential superhard RuO_2 phases. The structures, relative stabilities, and the elastic constants and bulk moduli of these phases have been calculated within local-density approximation (LDA) and generalized gradient approximation (GGA). In RuO_2, the LDA and GGA approximations yield smaller and larger lattice constants, respectively, for the Pa3-bar-RuO_2 structure. The internal structural parameter for oxygen atoms in the Pa3-bar structure has a volume dependence that differs from the experimental result and therefore implies a significantly different compression mechanism. The calculated bulk moduli are very similar for the fluorite and Pa3-bar structures and therefore apparently independent of the internal structural parameter. The structure and ...

2000-04-15

110

Effects of the. cap alpha. -adrenoceptor antagonists phentolamine, phenoxybenzamine, and Idazoxan on sympathetic blood flow control in the periodontal ligament of the cat  

Energy Technology Data Exchange (ETDEWEB)

Blood flow changes in the periodontal ligament (PDL) were measured indirectly by monitoring the local clearance of /sup 125/I/sup -/ during electric sympathetic nerve stimulation or close intra-arterial infusions of either noradrenaline (NA) or adrenaline (ADR) before and after administration of phentolamine (PA), phenoxybenzamine (PBZ) or Idazoxan (RX). At the doses used in the present study, PA was the only antagonist that significantly reduced the blood flow decrease seen on activation of sympathetic fibers, although PBZ also reduced this response. Idazoxan, however, did not induce the consistent effect on blood flow decreases seen on sympathetic activation. All three ..cap alpha..-adrenoceptor antagonists almost abolished the effects of exogenously administered NA and ADR. The results suggest the presence of functional post-junctional adrenoceptors of both the ..cap alpha.. 1 and ..cap alpha.. 2 subtypes in the sympathetic regulation of the ...

1988-01-01

111

Control of diffusion of implanted boron in preamorphized Si: Elimination of interstitial defects at the amorphous-crystal interface  

Energy Technology Data Exchange (ETDEWEB)

Transient-enhanced diffusion (TED) during thermal annealing of ion-implanted B in Si is well established and attributed to the ion-induced, excess interstitials. On the other hand, the mechanism to account for TED of B in preamorphized (PA) Si remains unclear. Enhanced diffusion of the B persists in regrown layers even though the ion-induced interstitial defects responsible for TED in B{sup +}-only implanted Si are eliminated following regrowth. To test the hypothesis that TED in PA Si results from the {open_quotes}excess{close_quotes} interstitial-type defects below the amorphous-crystalline (a-c) interface, a buried PA layer has been recrystallized from the surface inward to the SiO{sub 2} interface of silicon-on-insulator material to eliminate all possible sources of excess interstitials. The effect on B diffusion and the role of the residual interstitial-type defects will be discussed. {copyright} {ital 1999 American ...

1999-02-01

112

CO2 Capture by Absorption with Potassium Carbonate  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. In Campaign 3 of the pilot plant, the overall mass transfer coefficient for the stripper with 7 m MEA decreased from 0.06 to 0.01 mol/(m{sup 3}.s.kPa) as the rich loading increased from 0.45 to 0.6 mol CO{sub 2}/mol MEA. Anion chromatography has demonstrated that nitrate and nitrite are major degradation products of MEA and PZ with pure oxygen. In measurements with the high temperature FTIR in 7 m MEA the MEA vapor pressure varied from 2 to 20 Pa at 35 to 70 C. In 2.5 m PZ the PZ vapor pressure varied from 0.2 to 1 Pa from 37 to 70 C.

2005-01-26

113

Tetracycline treatment of periodontal disease in the beagle dog  

Energy Technology Data Exchange (ETDEWEB)

Bone-seeking radiopharmaceutical uptake (BSRU) was used to examine alveolar bone metabolism in a longitudinal study of tetracycline efficacy in beagle dogs. BSRU was measured in untreated control dogs and in beagles receiving either 250 mg or 500 mg oral tetracycline-HCl daily for 16 months. The rate of bone loss was determined for radiographs taken semiannually for a 6-month pretreatment period and for a 24-month treatment period. Measurements of BSRU obtained at month 16 of treatment were correlated with rates of bone loss determined radiographically in an attempt to determine whether BSRU was indicative of the subsequent rate of bone loss. A reduced rate of alveolar bone loss was found in the 500 mg tetracycline group at month 16 of the study relative to the untreated controls which was consistent with the decreased bone-seeking radiopharmaceutical uptake observed in this group. A significantly increased BSRU (p<.0001) was found in the ...

1982-01-01

114

Somatostatin receptor scintigraphy might be useful for detecting skeleton abnormalities in patients with multiple myeloma and plasmacytoma  

International Nuclear Information System (INIS)

Somatostatin receptor expression has been demonstrated on a number of plasma cell lines. Therefore, we questioned whether somatostatin receptor scintigraphy (SRS) can be used to demonstrate in vivo multiple myeloma (MM) activity. SRS was performed in newly diagnosed (n = 9) or relapsing (n = 18) MM patients or in patients with localized plasmacytoma (n = 2). The results were compared with radiographic findings. A positive SRS was demonstrated in 44% of the newly diagnosed patients, in 83% of the relapsed patients and in both patients with plasmacytoma. The SRS findings corresponded with radiographic abnormalities in 40% of the patients. However, in relapsed patients 60% demonstrated increased SRS uptake in areas without new radiographic abnormalities. The positive SRS corresponded with histologically proven disease activity and responded upon treatment. Moreover, immunohistochemical staining of MM material demonstrated ...

2010-01-01

115

Radionuclide scintimetry for diagnosis of complications following femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

A scintimetric study using Tc-99m MDP was made of 54 patients with delayed union, nonunion, or late segmental collapse of the femoral head, 4-92 months after femoral neck fracture. In radiographically verified collapse, the radionuclide uptake ratio between the femoral head on the fractured and on the intact side (HHR) was significantly higher than in fractures resulting in delayed union or nonunion. On the basis of scintimetric and radiographic findings, the patients with healing disturbances could be divided into three groups, characterized by the following features: (1) Satisfactory post-reduction position of the fracture without subsequent redisplacement and a high HHR, which as a rule turned out to be delayed union; (2) The same radiographic pattern but with a lower HHR, which in most cases resulted in nonunion; (3) Inadequate reduction or early redisplacement of the fracture with a high HHR, which resulted in ...

1984-01-01

116

Femoral neck buttressing: a radiographic and histologic analysis  

International Nuclear Information System (INIS)

Objective. To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty.Design. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery.Results. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any ...

2000-10-01

117

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it reduces image contrast. ...

1998-02-01

118

Radionuclide Distribution Coefficients for Sediments Collected from Borehole 299-E17-21: Final Report for Subtask 1a  

Energy Technology Data Exchange (ETDEWEB)

Over 360 distribution coefficients (KJ for cesium, iodine, selenium, Strontium, technetium, and uranium were measured in fiscal year 1998 using 20 sediments collected fkom borehole 299-El 7-21 on the Hanford Site as part of the Immobilized Low-Activity Waste-Performance Assessment (ILAW-PA). Additionally, the pH and cation-exchange capacity (a measure of the total quantity of cations that a sediment can adsorb) of these sediment samples were measured. The sediment samples originated from the Hanford formation (informal name). Statistical analyses, using Student's t-test and correlation were conducted with the measured values. There were no significant differences between layers 1 and 2 for the selenium, strontium, technetium, and uranium & values (statistics could not be applied to evaluate layer 3 &values). Significant differences between the cesium and iodine&values for layem 1 and 2 were observed. However, these differences were modest and ...

1998-10-14

119

Transportation for reprocessing of the spent nuclear fuel (SNF) of TVR ITEP research reactor and proposals for SNF management plans for the RA reactor  

International Nuclear Information System (INIS)

The TVR heavy water research reactor was deployed at Moscow Institute of Theoretical and Experimental Physics. In 1990, the final batch of the spent nuclear fuel from this reactor was shipped to Production Association (PA) 'Mayak' for reprocessing. The SNF removal was a stage of the reactor decommissioning activities. The designs of the TVR reactor and its fuel elements are similar to the RA reactor designs. Two ways of the RA reactor SNF transportation to PA 'Mayak' have been considered: in aluminum barrels and in additional canisters using respectively TUK-32 and TUK-19 shipping casks. The practical experience and the equipment used to prepare for the TVR reactor SNF removal can be helpful to the RA reactor personnel in finding the best way to perform these engineering operations. (author)

2003-03-09

120

Thermogravimetric and wide angle X-ray diffraction analysis of thermoplastic elastomers from nylon copolymer and EPDM rubber  

British Library Electronic Table of Contents (United Kingdom)

Nylon copolymer (PA6, 66) and ethylene propylene diene (EPDM) blends with and without compatibilizer were prepared by melt mixing using Brabender Plasticorder. The thermal stability of nylon copolymer (PA6, 66)/ethylene propylene diene rubber (EPDM) blends was studied using thermogravimetric analysis (TGA). The morphology of the blends was investigated using scanning electron microscopy (SEM). In this work, the effects of blend ratio and compatibilisation on thermal stability and crystallinity were investigated. The incorporation of EPDM rubber was found to improve the thermal stability of nylon copolymer. The kinetic parameters of the degradation process were also studied. A good correlation was observed between the thermal properties and phase morphology of the blends. By applying Coats ...

2008-01-01

121

Theoretical study of the non-steady discharge at atmospheric pressure in pin-plate system and its application for ozone production  

International Nuclear Information System (INIS)

In this paper as a result of the theoretical studies and a numerical simulation we presented the following main conclusions: (i) for humid air at increasing pressure of 1.0133 10"5 Pa until 5.0665 10"5 Pa ozone concentrations during 2 centre dot 10"-"3 s become higher in 22 times. This fact we clear with structure of ozone-production reactions. In this case the harmful NO_x concentrations are 2-3 order lower than ozone one; (ii) it is shown that nitrogen is useful to ozone production in the discharge; (iii) based on ion collection we cleared increasing ignition discharge voltage at growing ozone concentrations even with low ozone concentrations.

122

Photosynthetic energy storage efficiency in Chlamydomonas reinhardtii, based on microsecond photoacoustics  

British Library Electronic Table of Contents (United Kingdom)

Using a novel, pulsed micro-second time-resolved photoacoustic (PA) instrument, we measured thermal dissipation and energy storage (ES) in the intact cells of wild type (WT) Chlamydomonas reinhardtii, and mutants lacking either PSI or PSII reaction centers (RCs). On this time scale, the kinetic contributions of the thermal expansion component due to heat dissipation of absorbed energy and the negative volume change due to electrostriction induced by charge separation in each of the photosystems could be readily distinguished. Kinetic analysis revealed that PSI and PSII RCs exhibit strikingly different PA signals where PSI is characterized by a strong electrostriction signal and a weak thermal expansion component while PSII has a small electrostriction component and large thermal expansion....

2011-01-01

123

Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer  

International Nuclear Information System (INIS)

A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to image biological tissue ...

2008-05-07

124

11. Preparation of natural radioactive materials  

International Nuclear Information System (INIS)

Uranium and thorium ores are the source of natural radionuclides. Briefly described are the original and current methods of long-lived nuclide separation ("2"3"8U, "2"3"5U, "2"2"6Ra, "2"3"0Th, "2"3"1Pa, "2"2"7Ac, "2"3"2Th, "2"2"8Ra+"2"2"8Ac, "2"2"8Th), some short-lived nuclides ("2"3"4Th and "2"2"8Ac), radon, short-lived radon daughter products and long-lived radon daughter products ("2"1"0Pb, "2"1"0Bi, "2"1"0Po). Some nuclides, such as "2"1"0Po or "2"3"1Pa can more easily be producedin reactors. (Ha).

125

Treatment of asymptomatic internal resorption of a maxillary premolar tooth in a military working dog.  

Science.gov (United States)

An asymptomatic pink discoloration of a maxillary right fourth premolar tooth was discovered during a routine oral examination on a 9 year-old Belgian Malinois dog. A radiolucent lesion was seen in the pulpal chamber on radiographic examination. The lesion had perforated the mesiobuccal root of the tooth. The primary differential diagnosis was idiopathic internal resorption. The tooth was treated by partial resection (removal of the mesiobuccal root and associated crown). A vital pulpotomy and amalgam restoration was performed on the remaining tooth structure. A follow-up 1 year later demonstrated a successful treatment outcome. The animal was asymptomatic and able to perform military duties. Clinical and radiographic signs of healing were evident and the tooth was functional. PMID:10518874

1998-12-01

126

Sequential scintimetry after femoral neck fracture. Methodologic aspects and prediction of healing complications  

Energy Technology Data Exchange (ETDEWEB)

Forty-five patients with recent cervical hip fractures were included in a prospective, clinical, radiographic and sequential scintimetric study. Striking changes in radionuclide uptake over the entire hip region on the fracture side were found during the first 5 postoperative months. Fractures that healed without complications showed the highest relative femoral head uptake at 1 week and a peak value at 6 weeks, followed by a gradual decline at the subsequent examinations. Fractures with complications (redisplacement, nonunion, or late segmental collapse) showed a lower initial uptake and a more gradual increase and only a slight tendency towards increased uptake after 3 months. The accuracy in predicting nonunion with scintimetric examination alone is high both at 1 and at 6 weeks, and the accuracy is almost equally high with combined scintimetric, radiographic, and clinical assessment 3-5 months postoperatively.

1987-01-01

127

Radiation-induced large intracranial vessel occlusive vasculopathy.  

Science.gov (United States)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and confirmed by pathologic examination. The clinical, angiographic, ...

1980-01-01

128

Radiation-induced large intracranial vessel occlusive vasculopathy  

Energy Technology Data Exchange (ETDEWEB)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and confirmed by pathologic examination. The clinical, angiographic, ...

1980-01-01

129

Destructive spondyloarthropathy in hemodialysis patients. Report of four cases and prospective study  

Energy Technology Data Exchange (ETDEWEB)

A destructive spondyloarthropathy is reported in four patients undergoing maintenance hemodialysis for chronic renal disease. In a separate investigation a controlled, prospective radiographic study of the cervical spine revealed this spondyloarthropathy in 4 (15%) of 26 long-term dialysis patients. A single disk level was involved in three patients, and two disc levels were involved in one patient. This spondyloarthropathy correlated with the duration of dialysis but not with the radiographic evidence of renal osteodystrophy or severity of laboratory abnormalities associated with hyperparathyroidism. Three of these four patients also had discovertebral erosions or destruction involving the lumbar spine. Cervical spine flexion views revealed evidence of ligamentous laxity or instability in three (12%) dialysis patients, all with vertebral resorption and disc space narrowing. It is postulated that this instability may contribute to the ...

1988-04-01

130

A method of stereotaxic localization adopted for conventional and digital radiography  

International Nuclear Information System (INIS)

A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various ...

1986-01-01

131

Sinonasal malignant tumors involvement of the orbit and skull: a computed tomography study  

International Nuclear Information System (INIS)

Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through the ethmoidal (70%) and orbital roof (30%). ...

2002-01-01

132

Effect of dose on lead retention and distribution in suckling and adult female mice  

Energy Technology Data Exchange (ETDEWEB)

Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free /sup 203/Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age groups. Though uptake of lead into brain and into femur was observed to be directly related to dose over a ...

1980-01-01

133

Thermal properties and thermal reliability of eutectic mixtures of some fatty acids as latent heat storage materials  

Energy Technology Data Exchange (ETDEWEB)

The present study deals with two subjects. The first one is to determine the thermal properties of lauric acid (LA)-stearic acid (SA), myristic acid (MA)-palmitic acid (PA) and palmitic acid (PA)-stearic acid (SA) eutectic mixtures as latent heat storage material. The properties were measured by the differential scanning calorimetry (DSC) analysis technique. The second one is to study the thermal reliability of these materials in view of the change in their melting temperatures and latent heats of fusion with respect to repeated thermal cycles. For this aim, the eutectic mixtures were subjected to 360 repeated melt/freeze cycles, and their thermal properties were measured after 0, 90,1 80 and 360 thermal cycles by the technique of DSC analysis. The DSC thermal analysis results show that the binary systems of LA-SA in the ratio of 75.5:24.5 wt.%, MA-PA in the ratio of 58:42 wt.% and PA-SA in the ratio of ...

2004-02-01

134

Sunlight-induced efficient and selective photocatalytic benzene oxidation on TiO(2)-supported gold nanoparticles under CO(2) atmosphere.  

Science.gov (United States)

The sunlight-induced photocatalytic oxidation of aqueous benzene on TiO(2)-supported gold nanoparticles was considerably improved when the reaction was conducted under a CO(2) atmosphere. 13% yield and 89% selectivity of phenol was obtained on P25-supported gold nanoparticles under 230 kPa of CO(2). PMID:21952312

2011-09-26

135

Salmonella enterica Serovar Typhimurium Expressing a Chromosomally Integrated Copy of the Bacillus anthracis Protective Antigen Gene Protects Mice against an Anthrax Spore Challenge  

UK PubMed Central (United Kingdom)

Protective immunity against infection with Bacillus anthracis is almost entirely based on a response to the protective antigen (PA), the binding moiety for the two other toxin components....Full Text Available

2003-07-01

136

Radioanalytical chemistry. Vol. 2  

International Nuclear Information System (INIS)

This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).

1989-01-01

137

QUEST2: Project plan for preliminary analysis/system architecture phase (PA/SA)  

Energy Technology Data Exchange (ETDEWEB)

This Project Management Plan combines the project management deliverables from the P+ methodology that are applicable to this part of the QUEST2 work. This consolidation reflects discussions with WHC QA regarding an appropriate method for ensuring that P+ deliverables fulfill the intent of WHC-CM-3-10 and QR-19.

1995-03-08

138

Methods for increasing the stability and reliability of combined energy systems. Sposoby povysheniya ustoychivost i nadezhnosti ob'yedinennykh energosistem  

Energy Technology Data Exchange (ETDEWEB)

An increase in the stability and reliability of a combined power system (OES) is achieved through using a control panel (PA) and regulation systems. A substantial part of the works published in this collection of works is used in the combined power systems of the Urals, the Northwest and Central Asia.

1983-01-01

139

Italmatch extends Phoslite flame retardant range  

British Library Electronic Table of Contents (United Kingdom)

European phosphorus derivatives manufacturer Italmatch Chemicals SpA has expanded its Phoslite range of fully colourable flame retardants for polymers with the addition of Phoslite B85AX. The company reports that its Phoslite technology is already `successfully consolidated' in polypropylene (PP) applications and, with introduction of the new product, is now starting to expand into polyamide PA6 and polybutylene terephthalate (PBT) applications.

2010-01-01

140

High-resolution primary ion beam probe for SIMS  

Energy Technology Data Exchange (ETDEWEB)

High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.

2004-06-15

141

Fifty successful years of the Institute of Plasma Physics, Academy of Sciences of the Czech Republic  

International Nuclear Information System (INIS)

The history of the Czech Institute of Plasma Physics is highlighted. The article is structured as follows: Cyclic accelerators; Interaction of an external high-frequency field and high-temperature plasma - the tokamak; Interaction of an external high-frequency field and high-temperature plasma - pulse plasma systems; Low-temperature plasma - plasma technologies and new materials; Laser plasma - PALS; Optical diagnosis; and Teaching, conferences and international cooperation. (P.A.)

142

Externally fired combined cycle for electric power generation from coal  

Energy Technology Data Exchange (ETDEWEB)

The externally fired combined cycle is emerging as an economically viable repowering options for old non-competitive coal fired steam plants. This paper describes the initial operation of a pilot plant located at Kennebunk, Maine and the initial work on the repowering of a 48MW coal fired steam plant located in Warren, PA.

1994-12-31

143

Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.  

Science.gov (United States)

Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine ...

2011-09-26

144

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-11-01

145

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

International Nuclear Information System (INIS)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-01-01

146

Screen-film-combinations for radiography - present and future spectrum of application  

Energy Technology Data Exchange (ETDEWEB)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.

1985-01-01

147

Screen-film-combinations for radiography - present and future spectrum of application  

International Nuclear Information System (INIS)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).

148

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

149

Principium research of real-time neutron radiography in No. 300 reactor  

International Nuclear Information System (INIS)

The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper

2002-12-01

150

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

Energy Technology Data Exchange (ETDEWEB)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both ...

1999-09-01

151

Esophageal perforation following bite of inner tube of automobile tyre: An unusual cause of barotrauma  

UK PubMed Central (United Kingdom)

An 8-year-old child presented with severe chest pain and respiratory distress after he accidentally bit an automobile tyre tube which burst into his mouth. The chest radiograph revealed left-sided pneumothorax....Full Text Available

2010-01-01

152

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

153

Demonstration of realtime radiography on pipeline girth welds: Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional radiography has been the accepted nondestructive testing (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of realtime x-ray system ...

1988-09-01

154

Study of in-medium $\\omega$ meson properties in Ap, pA and AA collisions  

CERN Document Server

We propose to investigate the in-medium properties of vector $\\omega$ mesons at the normal nuclear density in Ap(pA) collisions and at higher density in AA collisions at the ITEP accelerator facility TWAC. Using of the inverse Ap kinematics will permit us to study the $\\omega$ meson production in a wide momentum interval included the not yet explored range of small meson momenta relative to the projectile nuclei where the mass modification effect in nuclear matter is expected to be the strongest. Momentum dependence of the in-medium $\\omega$ meson width will be studied in the traditional pA kinematics. We intend to use the electromagnetic calorimeter for reconstruction of the $\\omega$ meson invariant mass by detecting photons from the $\\omega \\to \\pi^{0}\\gamma \\to 3\\gamma$ decay. The model calculations and simulations with RQMD generator show feasibility of the proposed experiment. Available now intensity of the ion beams provides a possibility to collect ...

2008-01-01

155

Probing gluon and heavy-quark nuclear PDFs with photon + heavy quark production in pA collisions  

CERN Document Server

We present a detailed phenomenological study of direct photon production in association with a heavy-quark jet in pA collisions at the Relativistic Heavy Ion Collider (RHIC) and at the Large Hadron Collider (LHC) at next-to-leading order in QCD. The dominant contribution to the cross-section comes from the gluon--heavy-quark (gQ) initiated subprocess, making \\gamma + Q production a process very sensitive to both the gluon and the heavy-quark parton distribution functions (PDFs). Additionally, the RHIC and LHC experiments are probing complementary kinematic regions in the momentum fraction x_2 carried by the target partons. Thus, the nuclear production ratio R^{\\gamma+Q}_{pA} can provide strong constraints, over a broad x-range, on the poorly determined nuclear parton distribution functions which are extremely important for the interpretation of results in heavy-ion collisions.

2010-01-01

156

Preliminary assessment report for National Guard Training Center, Georgia Army National Guard, Fort Stewart, Georgia. Installation restoration program  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of the preliminary assessment (PA) conducted by Argonne National Laboratory at the Georgia Army National Guard (GAARNG) facility near Hinesville, Georgia, known as the National Guard Training Center (NGTC). Preliminary assessments of federal facilities are being conducted to compile the information necessary for completing preremedial activities and to provide a priority basis for completing corrective actions (where necessary) in response to releases of hazardous substances. The principal objective of the PA is to characterize the site accurately and determine the need for further action by examining previous site activities, types and quantities of hazardous substances utilized, and potential pathways by which contamination could affect public health and the environment. The scope of this assessment is limited to the facilities and past activities contained within the NGTC. Preliminary assessment site score ...

1993-07-01

157

Plasma nitriding of substrate by using supersonic nitrogen plasma jet; Cho onsoku chisso plasma jet wo mochiita Ti kizai no plasma chikka  

Energy Technology Data Exchange (ETDEWEB)

Plasma nitriding of a Ti substrate is carried out under a low ambient pressure below 3kPa, and a plasma torch is prepared on a trial basis which is provided with a supersonic expansion nozzle considered to expand plasma jet optimally and to be effective for suppressing the occurrence of shock wave. The system used for the study is provided with a specimen holder having the function of adjusting the distance between the nozzle outlet and the substrate inside the vacuum chamber which is provided with a plasma torch in the flange member. The plasma torch is so structured that a supersonic expansion nozzle can be installed at the tip of the plasma torch. In this process wherein plasma jet is employed, hard nitrided layer can be formed by plasma irradiation for a short time even under such low pressure as less than 3kPa by setting adequate experimental conditions. It is made clear that the use of a supersonic nozzle corresponding to the internal ...

1997-07-01

158

Phase Chemistry of Tank Sludge Residual Components  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate nearby groundwaters with radionuclides and RCRA metals. Performance assessment (PA) calculations must be carried out prior to closing the tanks. This requires developing radionuclide release models from the sludges so that the PA calculations can be based on credible source terms. These efforts continued to be hindered by uncertainties regarding the actual nature of the tank contents and the distribution of radionuclides among the various phases. In particular, it is of vital importance to know what radionuclides are associated with solid sludge components. Experimentation on actual tank sludges can be difficult, dangerous ...

2002-04-02

159

Innovative active modified atmosphere packaging improves overall quality of fresh-cut red chard baby leaves  

British Library Electronic Table of Contents (United Kingdom)

The antimicrobial effects and quality changes of O2, He, N2 or N2O-enriched active modified atmosphere packaging -MAP- (100 kPa initial gas partial pressure) compared to a chlorinated -100 mg L-1 NaClO- passive MAP (control) in fresh-cut Red Chard baby leaves up to 8 days at 5 degreeC were studied. High O2 MAP (>85 kPa O2) inhibited natural microflora growth during 7 days at 5 degreeC. Regarding control treatment, no differences for He and N2O-enriched MAPs on microbial growth were found although control samples were previously disinfected. Initial total phenolics content (613 mg ChAE kg-1 fw) increased up to 61-93% after 6 days at 5 degreeC under O2, He, and N2-enriched MAPs. Vitamin C content decreased up to 67% after shelf life in control samples while lower decreases were monitored in ...

2011-01-01

160

Host derived inflammatory phospholipids regulate rahU (PA0122) Gene, Protein, and Biofilm Formation in Pseudomonas aeruginosa  

British Library Electronic Table of Contents (United Kingdom)

This study describes the role of "inflammatory" oxidized (Ox) phospholipids in regulation of rahU (PA0122) expression and biofilm formation in Pseudomonas aeruginosa (383) wild type (rahU+) and rahU mutant (rahU-) strains. Functional analysis of RahU protein from P. aeruginosa in presence of Ox-phospholipids show: (a) LysoPC modulates RahU gene/and protein expression in rahU+ cells; (b) rahU promoter activity is increased by lysoPC and inhibited by PAPC, Ox-PAPC and arachidonic acid; the latter inhibitory effect can be reversed by lysoPC, which was enzymatically derived from PAPC; (c) biofilm formation increased in rahU- cells as compared to rahU+; and (d) inhibition of rahU promoter activity by PAPC and AA (but not lysoPC) showed significantly augmented biofilm formation in rahU+ but not ...

2011-01-01

161

Bip overexpression, but not CHOP inhibition, attenuates fatty-acid-induced endoplasmic reticulum stress and apoptosis in HepG2 liver cells  

British Library Electronic Table of Contents (United Kingdom)

Aims: In this study we investigated whether attenuation of endoplasmic reticulum stress (ER stress) could protect HepG2 cells from free fatty acid (FFA)-induced apoptosis. Main methods: Human liver cell line HepG2 cells were exposed to Sodium Palmitate (Pa) or Sodium Oleate (Ol). Apoptosis and ER stress of HepG2 cells were analyzed with flow cytometry, real-time RT-PCR and Western Blotting. An expression plasmid encoding for the ER chaperone immunoglobulin heavy chain-binding protein (Bip) was transfected into HepG2 cells to attenuate ER stress. Small interfering RNA siCHOP was used to knockdown the expression of C/EBP Homologous Protein (CHOP) in HepG2. Key findings: Pa led to cytotoxicity and apoptosis in HepG2 cells in a dose-dependent pattern and also induced ER stress indicated by inc...

2010-01-01

162

The role of Computerized Tomography in osteoid-osteoma diagnosis  

International Nuclear Information System (INIS)

Alcaptonuria is a rare autosomal recessive metabolic disease, due to the lack of homogentisic acid oxidase. The following accumulation of homogentisic acid brings about a black discoloration of both the urine alcaptonuria) and connective tissue (ochronosis). The ochronotic alterations into joint cartilages cause degenerative arthropathy and osteopenia. The radiological features of three unrelated cases of alcaptonuria are reported. Radiographic abnormalities of ochconotic arthropathy are found in both the spine and the extraspinal joints. In the spine, the progressive calcification and ''vacuum'' phenomenon of disc spaces are the most characteristic findings. Disc space narrowing is associated with calcification and marginal sclerosis of vertebral bodies and is accentuated by osteopenia. Osteophytes are usually absent or of small size; neverthless progressive formation of marginal intervertebral bridges and obliteration of disc spaces at multiple levels ...

1988-01-01

163

MR imaging of the lateral collateral ligaments after ankle sprain; Aussenbandrupturen des Sprunggelenkes - Darstellung mit der MRT vor und nach funktioneller Therapie  

Energy Technology Data Exchange (ETDEWEB)

35 patients with ankle sprain were examined by MRI and stress radiographs. 13 were operated afterwards, 22 patients underwent a functional conservative therapy and were examined by MRI and stress radiographs and second time after three months. MRI reports were correct in 12 of 13 operated cases. After conservative therapy we did not find any disrupted ankle ligament. MRI showed intact ligaments thickened by scar. (orig./MG) [Deutsch] 35 Patienten mit klinischem Verdacht auf Aussenbandruptur wurden mit der MRT untersucht. 13 Patienten wurden operiert, 22 konzervativ therapiert. Letztere wurden nach drei Monaten erneut mit MRT und gehaltenen Aufnahmen untersucht. Die MRT-Befunde stimmten in 12 von 13 Faellen mit den operativ erhobenen Befunden ueberein. Nach dreimonatiger konzervativer Therapie waren alle 22 Sprunggelenke stabil. Die rupturierten Baender stellten sich verdickt und durchgaengig dar. (orig./MG)

1995-09-01

164

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

International Nuclear Information System (INIS)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise ...

1987-01-01

165

Ewing's sarcoma. Radiographic pattern of healing and bony complications in patients with long-term survival  

International Nuclear Information System (INIS)

The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and that any localized lysis at the primary site is suspicious for recurrence or ...

166

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea ...

1986-01-01

167

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium ...

2002-04-01

168

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium ...

2002-04-01

169

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...

170

Computed tomography of the chest in the postoperative recurrences of bronchogenic carcinoma  

International Nuclear Information System (INIS)

The authors describe the different types of postoperative carcinoma recurrences, as seen on CT examinations of the chest, in 38 patients who underwent different surgical procedures for bronchogenic carcinoma (12 pneumonectomies, 22 lobectomies, 2 segmentectomies, and 2 atypical resections). The recurrences were classified as follows: 1) recurrence in the bronchial stump; 2) limph node enlargement; 3) recurrence in the thoracic wall; 4) recurrence in the residual lobe; 5) pleural effusion; 6) nodule in the contralateral lung. The CT findings, Correlated with those from plain chest radiographs and clinical simptoms, indicate a higher incidence of recurrences in the hilar region, either in the bronchial stump or as node after total and subtotal resection are separately analyzed. While after pneumonectomy plain chest radiographs fail to demonstrate the recurrence in most cases, so that CT is nearly always mandatory, after subtotal resection the ...

1990-01-01

171

Thermal degradation and crystallisation studies of reactively compatibilised polymer blends  

British Library Electronic Table of Contents (United Kingdom)

The thermal degradation and crystallisation behaviours of polyamide12/isotactic polypropylene (PA12/PP) blends were studied. Effects of blend ratio and compatibiliser concentration on the thermal degradation properties of the blends were analysed. The activation energy for degradation in compatibilised and uncompatibilised blends computed using Horowitz-Metzger equation was reported. The blend ratio as well as the presence of compatibiliser has significant effect on the thermal stability of the blends. Phase morphology was found to be one of the decisive factors that affected the thermal stability of both uncompatibilised and compatibilised blends. Melting and crystallisation behaviours of the blends in the presence and absence of compatibiliser were evaluated. It was observed that blendin...

2008-01-01

172

Simple method for the high-temperature isolation of /sup 111/In from silver  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for the quantitative high-temperature isolation of /sup 111/In from silver irradiated by ..cap alpha..-particles into a gas phase containing a mixture of HCl and H/sub 2/O with a total pressure of about 3 Pa for these gases. It is shown that the indium evolved into the gas phase probably occurs in the form of at least three compounds, viz.., the trichloride, monochloride, and oxychloride, which have adsorption temperatures on quartz of around 385, 475, and 655 K, respectively. All these compounds are readily washed from the surface of quartz apparatus by a weak (0.05 M) solution of hydrochloric acid.

1987-07-01

173

Simple method for high-temperature separation of thallium isotopes from a bulk lead target  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for the quantitative isolation of radiothallium in gas form from proton-bombarded lead of mass up to 20 g. The molten lead is kept at about 800 K in hydrofluoric-acid vapor (HF/H/sub 2/O approx. = 1) at a reduced pressure (less than or equal to4 Pa). We used 99.9% lead with the U-240 cyclotron at the Nuclear Research Institute, Academy of Sciences of the Ukrainian SSR, or the phasotron at the Join Nuclear Research Institute, which gave protons at 65 and 680 MeV correspondingly.

1988-03-01

174

Simple method for high-temperature separation of thallium isotopes from a bulk lead target  

International Nuclear Information System (INIS)

A method is proposed for the quantitative isolation of radiothallium in gas form from proton-bombarded lead of mass up to 20 g. The molten lead is kept at about 800 K in hydrofluoric-acid vapor (HF/H_2O #approx =# 1) at a reduced pressure (#<=#4 Pa). We used 99.9% lead with the U-240 cyclotron at the Nuclear Research Institute, Academy of Sciences of the Ukrainian SSR, or the phasotron at the Join Nuclear Research Institute, which gave protons at 65 and 680 MeV correspondingly.

175

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

176

Proton production in the kinematically forbidden region  

Energy Technology Data Exchange (ETDEWEB)

Proton production in pA interactions in the kinematically forbidden region is studied using the intranuclear cascade model for the primary proton energies 7.5 and 8.9 GeV/c. The region of secondary-proton kinetic energies above 100 MeV, where the contribution from the post-cascade stages of the interaction is small, is studied. The calculated energy and angular spectra are in good agreement with the experimental ones. The mechanisms of multiple rescattering of particles on the nucleons of the nucleus and ..pi..-meson absorption on a two-nucleon flucton are analyzed. The kinematical ranges where these mechanisms operate are determined.

1985-08-01

177

Production of Group IIA atomic and molecular negative ion beams in a cesium-sputter negative ion source  

Energy Technology Data Exchange (ETDEWEB)

The results of an investigation on the production of Group IIA atomic and molecular negative ion beams formed in a cesium-sputter negative ion source are presented. The sputtering material was formed by pressing pellets of stoichiometric mixtures of the Group IIA element carbonates and 10% copper powder. Negative ions of several alkaline-earth elements and their oxides have been observed. Beam intensities as high as 180 pA have been observed for Sr{sup -}and 20 nA for SrO{sup -}. (orig.).

1996-09-11

178

Production of Group IIA atomic and molecular negative ion beams in a cesium-sputter negative ion source  

International Nuclear Information System (INIS)

The results of an investigation on the production of Group IIA atomic and molecular negative ion beams formed in a cesium-sputter negative ion source are presented. The sputtering material was formed by pressing pellets of stoichiometric mixtures of the Group IIA element carbonates and 10% copper powder. Negative ions of several alkaline-earth elements and their oxides have been observed. Beam intensities as high as 180 pA have been observed for Sr"-and 20 nA for SrO"-. (orig.).

1996-09-01

179

Nylon66 black unfilled regrind available, Bagadia Petrochem Pvt. Ltd., Mumbai, India - sell Nylon scrap  

Wastenet

... Best regards, Kunal Bagadia +91 9172964646 Contact Supplier Related Sell offers We can supply Nylon PA6 / 66 yarn Send a message to Bagadia Petrochem Pvt. Ltd. Mr.Kunal Bagadia Please enter the message Send Now Sell Offer Categories HDPE [1] Nylon [1] Contact details Bagadia Petrochem Pvt. Ltd. Contact name : Mr.Kunal Bagadia City : Mumbai Zip/Postal Code :...

180

Nanocomposites: a review of technology and applications  

British Library Electronic Table of Contents (United Kingdom)

Purpose - This paper aims to describe the technology and applications of nanocomposite materials. Design/methodology/approach - This paper discusses products, applications and technological developments in polymer, ceramic and metal nanocomposites. It concludes with a brief consideration of electronic component applications. Findings - It is shown that polymer nanocomposites and the materials used in their production are commercially available and finding applications in several industries, including automotive, military, food, electronics and leisure, due to their enhanced mechanical, electrical and thermal properties. Ceramic and metallic nanocomposites are at an earlier stage of development and a critical issue to resolve is optimising the dispersion of nanomaterials in the matrices. Pa...

2011-01-01

181

Ion-plasma nitriding of the alloyed steel using a low pressure arc plasma generator  

International Nuclear Information System (INIS)

A study is made into microhardness and structure of coatings on various system steels (37G2S, 25Kh5M, R6M5), obtained by ion nitriding in a low pressure (10"-"1 Pa) arc discharge plasma. A comparison of properties is accomplished for steels nitrided in an arc gas discharge and in a furnace. It is stated that ion-plasma nitriding in an arc gas plasma generator is an efficient method of alloy steels hardening which allows changing the structure and increasing the hardness of a surface layer up to rather great depth

2006-12-01

182

Inland penetration of sea breeze around Wolsung NPP site  

Energy Technology Data Exchange (ETDEWEB)

A three dimensional sea-land breeze model has been employed for the study on the inland penetration of sea breeze around Wolsung NPP site. In this study, the sea breeze simulation was carried out under the weak northwesterly geostrophic wind (3.2 m/s, 339 .deg.) at 850 hPa in Spring. The results showed that sea breezes developed near Wolsung site penetrated into about 20 km inland under the weak northwesterly geostrophic wind in Spring. This result agreed with observation data around Wolsung site on May 1996.

1997-07-01

183

Inland penetration of sea breeze around Wolsung NPP site  

International Nuclear Information System (INIS)

A three dimensional sea-land breeze model has been employed for the study on the inland penetration of sea breeze around Wolsung NPP site. In this study, the sea breeze simulation was carried out under the weak northwesterly geostrophic wind (3.2 m/s, 339 .deg.) at 850 hPa in Spring. The results showed that sea breezes developed near Wolsung site penetrated into about 20 km inland under the weak northwesterly geostrophic wind in Spring. This result agreed with observation data around Wolsung site on May 1996.

1997-11-06

184

High-frequency microseismicity in the rock salt of the Asse mine around the 945 m level; Hochfrequenz Mikroseismizitaet im Steinsalz der Asse um den 945-m-Bereich  

Energy Technology Data Exchange (ETDEWEB)

3407 events were registrated up to a distance of 300 m during the period from 12.10.1989 to 31.12.1990, of which 385 could be precisely located. Activities were determined in areas surrounding the dam construction traversal drifts and boreholes at the 875 m level, near the large cavern at 975 m depth, in drifts and caverns above the 875 m level and in the vicinity of the rock salt/carnallitite transition zone to the south-east of the 875 m level. Energies and source parameters were calculated by means of spectres. Energy variations range from 10 J to 10{sup -4} J, the source radii from 3.5 m to 0.2 m, the source dislocations from 10{sup -6} m to 10{sup -8} m, and the stress drops from 10{sup 5} Pa to 0.06 10{sup 5} Pa. Magnitude and type of events observed are usual for mines. The microseismic activity provides an insight into the origin as well as changes of stress and rock mechanical material properties. (orig./HP). [Deutsch] Im Zeitraum ...

1991-11-01

185

Boric acid effect in phenolic composites on tribological properties in brake linings  

International Nuclear Information System (INIS)

In the present work, using a pad-on-disc-type wear tester, the tribological properties of the pad next to the disk made of cast iron were investigated with changing the substance of the components. As well, micro-structural characterisation of braking pads was performed using scanning electron microscopy and also temperature outcome of the pads was examined at the temperatures of 50-400 "oC in the pressure of 1050 and 3000 kPa. Finally, the effect of environment to the pads was studied in water, salty water, oil and braking liquid media.

186

An influence of ion bombardment on plasma nitriding process of Ti6Al14V alloy at 843 K temperature  

International Nuclear Information System (INIS)

This work presents results of investigations on d.c. glow discharge nitriding of #alpha#+#beta# Ti-6Al-4V titanium alloy. The treatment was performed at 843 K in nitrogen-hydrogen atmosphere, pressure 300 Pa. Special attention was paid to nitriding mechanism and determination of the role of ion bombarding in nitriding process of titanium alloys. Produced as a result of d.c. plasma nitriding surface layers were subjected to macroscopic observations, microstructure studies, microhardness testing and X-ray analysis. (author)

2004-06-20

187

Visualization of right atrial appendix by Thallium-201 myocardial scintigraphy: concise communication  

Energy Technology Data Exchange (ETDEWEB)

The atrial myocardium has been barely visible with thallium-201 myocardial scintigraphy. This is probably related to the difference in size, distance from anterior chest wall, and small coronary blood flow of the atrium, compared with the ventricle. We have encountered eight cases of visualization of the right atrial appendix (RAA). The RAA was identified from multiple projections in all cases and sometimes confirmed by radionuclide angiocardiography. Evidence derived from ECG, chest radiographs, and cardiac catheterization, indicated that the most important factor in the visualization might be the displacement of the RAA to a more anterior position.

1980-10-01

188

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

189

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

190

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

191

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

192

Patterns of gallium-67 scintigraphy in patients with acquired immunodeficiency syndrome and the AIDS related complex  

Energy Technology Data Exchange (ETDEWEB)

Thirty-two patients with AIDS related complex (ARC) or acquired immunodeficiency syndrome (AIDS) underwent /sup 67/Ga scans as part of their evaluation. Three patterns of /sup 67/Ga biodistribution were found: lymph node uptake alone; diffuse pulmonary uptake; normal scan. Gallium-67 scans were useful in identifying clinically occult Pneumocystis carinii pneumonia in seven of 15 patients with ARC who were asymptomatic and had normal chest radiographs. Gallium scans are a useful ancillary procedure in the evaluation of patients with ARC or AIDS.

1987-07-01

193

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

194

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

195

Neutron radiography with the cyclotron, 5  

International Nuclear Information System (INIS)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).

1987-01-01

196

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

197

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

198

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

199

Impingement fracture of the anteromedial tibial margin: a radiographic sign of combined posterolateral complex and posterior cruciate ligament disruption  

Energy Technology Data Exchange (ETDEWEB)

Marginal fractures of the tibial plateau are associated with a high incidence of soft tissue injuries to the stabilising structures of the knee joint. Injuries to the anterior cruciate ligament are associated with the Segond fracture and impingement fractures of the posteromedial tibial plateau. Recognition of these fractures aids diagnosis of these injuries. Marginal fractures of the tibial plateau associated with posterior cruciate ligament injuries are less common, though recently a ''reverse'' Segond fracture has been recognised. We describe a fracture of the anteromedial tibial plateau associated with complete disruption of the posterior cruciate ligament and posterolateral complex. (orig.)

2001-02-01

200

Imaging Automation and Volume Tomographic Visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-11-14

201

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

202

FCR (Fuji Computed Radiography) in neurosurgery  

Energy Technology Data Exchange (ETDEWEB)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.

1988-08-01

203

FCR (Fuji Computed Radiography) in neurosurgery  

International Nuclear Information System (INIS)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).

1988-01-01

204

Estimation of armature condition in concrete with gamma-absorption method  

International Nuclear Information System (INIS)

Bases of the algorithm for assessing the reinforcement status in reinforced concrete products by gamma-absorption method are presented. Analytical equations are obtained for estimation of error of the parameter characterizing the degree of reinforcement destruction. It is recommended to use high-energy Bremsstrahlung sources-betatrons of 4-10 MeV maximum energy for testing products of 500-600 mm thick. Linear radiation attenuation factor (LAF) of concrete in estimated equation is replaced by effective LAF of concrete, and LAF of reinforcement and corrosion materials - by differential LAF. Corresponding LAF of nonevident form in the algorithm is assessed by the results of processing of direct-shadow radiographs of defectometers

205

Computer-aided diagnosis of bone tumours and tumour-like skeletal abnormalities in childhood  

Energy Technology Data Exchange (ETDEWEB)

The method, use and results of computer-aided diagnosis of bone tumours and tumour-like skeletal abnormalities in childhood are described. One hundred and twentyone histologically verified cases were analysed and subjected to computer-aided diagnosis. Statistical methods were used, resulting in an accuracy of 96.7% and 91.7% respectively. In order to obtain additional confirmation of the diagnosis, a so-called growth rate was calculated by the computer. This proved to be a reliable criterion for evaluating the biological behaviour of tumours, irrespective of the histological diagnosis. The reasons for misdiagnosis were discussed. Attention is drawn to the importance of an accurate analysis of the radiographs and its input into the computer.

1982-06-01

206

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

207

Combined Modality Treatment for Prostate Cancer With Dynamic Adaptive Radiation Therapy Using Four-Dimensional Image-Guided Intensity-Modulated Radiation Therapy and Brachytherapy  

British Library Electronic Table of Contents (United Kingdom)

Prostate cancer can be successfully treated using dynamic adaptive external beam radiation techniques along with interstitial brachytherapy to deliver curative therapies with low urinary, rectal and erectile function morbidity. Through the use of sophisticated, state-of-the art radiographic imaging for staging and treatment planning, a precise, individual design for treatment is accomplished. Symptom management and patient education are of paramount importance and are integrated throughout the treatment process.

2009-01-01

208

Characterization of jet breakup mechanisms observed from simulant experiments of molten fuel penetrating coolant  

Science.gov (United States)

The goal of this research program has been to add to our understanding of the breakup of molten fuel jets penetrating reactor coolant. Easily handled working fluids are used to simulate fuel jet breakup, so that detailed observations may be obtained from a relatively large number of experiments. The tools used for observing this behavior are high speed notion picture photography, Flash X-radiography, and X-ray cine. Jet breakup lengths are determined from motion pictures; the mechanisms by which the jets are fragmented may be inferred from radiographs.

1992-01-01

209

CT findings of foreign bodies in the chest: a pictorial essay  

Energy Technology Data Exchange (ETDEWEB)

The most common causes of tracheobronchial foreign bodies are peanuts in children, and meat and dentures in adults. The most common causes of esophageal foreign bodies are coins in children and meat in adults. It is passable to diagnose a foreign body by visualization on a chest radiograph, if the foreign bodies are radio opaque. However, if the foreign bodies are radiolucent and the patients do not remember the history of aspiration, it is important to evaluate CT findings for foreign bodies and their complications. We describe the CT findings of various thoracic foreign bodies in children and adults.

2008-05-15

210

Avascular necrosis associated with nailing of femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

Two patients with femoral neck fractures, one displaced and one undisplaced, are presented. Preoperative intravital staining with tetracycline and Tc-MDP scintimetry both showed intact femoral head circulation while Tc-MDP-scintimetry 1 week after operation showed pronounced circulatory deficiency. Sr/sup 85/-scintimetry performed at the same time was inconclusive. Segmental collapse was observed radiographically, 8 and 12 months postoperatively. The major vascular injury resulting in avascularity most probably occured during the procedure of osteosynthesis, and Tc-MDP-scintimetry was found suitable for early postoperative recognition of avascular necrosis in both fractures.

1983-01-01

211

Avascular necrosis associated with nailing of femoral neck fracture  

International Nuclear Information System (INIS)

Two patients with femoral neck fractures, one displaced and one undisplaced, are presented. Preoperative intravital staining with tetracycline and Tc-MDP scintimetry both showed intact femoral head circulation while Tc-MDP-scintimetry 1 week after operation showed pronounced circulatory deficiency. SR"8"5-scintimetry performed at the same time was inconclusive. Segmental collapse was observed radiographically, 8 and 12 months postoperatively. The major vascular injury resulting in avascularity most probably occured during the procedure of osteosynthesis, and Tc-MDP-scintimetry was found suitable for early postoperative recognition of avascular necrosis in both fractures. (author).

212

Application of the tracer technique to study on casting solidification  

International Nuclear Information System (INIS)

The results and techniques of radiographic study on solidification of iron and steel mould castings are described. The study was made to determine the causes of the mold castings defects. The liquid metal is either labelled in the ladle, or relabelled inside the mould in present time intervals. In the former case, the radioactive phosphorus is segregated in the last-solidifying casting locations, and in the latter, the radioactive phosphorous is distributed along the solid-liquid interface at the time of the next addition in turn. The solidification process parameters may be arrived at by the autoradiograms taken in the pipe-sensitive casting sections. Using these data it is possible to proceed to the proper modifications in the steel casting process.

213

The neuroendocrine hormone norepinephrine increases Pseudomonas aeruginosa PA14 virulence through the las quorum-sensing pathway.  

Science.gov (United States)

It has been proposed that the gastrointestinal tract environment containing high levels of neuroendocrine hormones is important for gut-derived Pseudomonas aeruginosa infections. In this study, we report that the hormone norepinephrine increases P. aeruginosa PA14 growth, virulence factor production, invasion of HCT-8 epithelial cells, and swimming motility in a concentration-dependent manner. Transcriptome analysis of P. aeruginosa exposed to 500 microM, but not 50 microM, norepinephrine for 7 h showed that genes involved in the regulation of the virulence determinants pyocyanin, elastase, and the Pseudomonas quinolone signal (PQS, 2-heptyl-3-hydroxy-4-quinolone) were upregulated. The production of rhamnolipids, which are also important in P. aeruginosa infections, was not significantly altered in suspension cultures upon exposure to 500 microM norepinephrine but decreased on semisolid surfaces. Swarming motility, a phenotype that is directly influenced by ...

2009-06-11

214

Phase equilibria of the Ba-Sm-Y-Cu-O system for coated conductor applications  

International Nuclear Information System (INIS)

The complex phase relationships near the BaO-poor region of the quaternary Ba-Sm-Y-Cu-O oxide system prepared in pure air (pO2=22 kPa, 950 oC) and in 0.1% O2 (pO2=100 Pa, 810 oC) have been determined. This investigation also included the subsolidus compatibilities in ten subsystems (Ba-Sm-Y-O, Ba-Sm-Cu-O, Ba-Y-Cu-O, Sm-Y-Cu-O, Ba-Sm-O, Ba-Y-O, Ba-Cu-O, Sm-Y-O, Sm-Cu-O, and Y-Cu-O), and the homogeneity range of five solid solutions (Ba(SmxY2-x)CuO5, (Sm,Y)2O3, (Sm,Y)2CuO4, (Y,Sm)2Cu2O5, and Ba(Sm,Y)2O4). The single phase range of the superconductor solid solution, (Ba2-xSmx)(Sm1-yYy)Cu3O6+z, and the phase compatibilities in its vicinity, which are particularly important for processing, are described in detail. The phase equilibrium data of the Ba-Sm-Y-Cu-O system will enable the improvement of the intrinsic superconducting properties of second-generation wires, and facilitate the flux-pinning process. -- Graphical Abstract: Phase diagram ...

2010-12-01

215

Lauric and palmitic acids eutectic mixture as latent heat storage material for low temperature heating applications  

Energy Technology Data Exchange (ETDEWEB)

Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, heat transfer coefficient between the heat transfer fluid (HTF) pipe and ...

2005-04-01

216

Electrochemistry and passivity of a Ti-15Mo-3Nb-3Al beta-titanium alloy in ambient temperature aqueous chloride solutions  

International Nuclear Information System (INIS)

To understand the effect of Mo-Nb additions on the electrochemical behavior of #beta#-titanium alloys in ambient temperature chloride solutions, characterization of the electrochemistry and passivity of a Ti-15Mo-3Al alloy (#beta#-21S) was undertaken. Both solution heat-treated (SHT) and peak-aged (PA) alloys exhibited passive anodic behavior in aerated and deaerated 0.6M NaCl, aerated and deaerated 0.6M NaCl adjusted to pH 1 with HCl, as well as aerated 5M HCl. X-ray photoelectron spectroscopy (XPS) performed after exposure to neutral 0.6M NaCl indicated that both PA and SHT #beta#-21S formed a predominantly TiO_2 film. Auger electron spectroscopy (AES) and cathodic kinetics suggest that the Mo and Nb alloying additions are incorporated into the oxide in amounts less than that found in the alloys. The predominance of the passivating TiO_2 may explain the similarity of the electrochemical behavior observed. However, in deaerated 5M HCl, all ...

217

Effect of steric hindrance on carbon dioxide absorption into new amine solutions. Thermodynamic and spectroscopic verification through solubility and NMR analysis  

Energy Technology Data Exchange (ETDEWEB)

Aqueous solutions of 2-amino-2-hydroxymethyl-1,3-propanediol (AHPD), a sterically hindered amine, was examined as a potential CO{sub 2} absorbent and compared with the most commonly used absorbent, monoethanolamine (MEA) solution, through equilibrium solubility measurements and {sup 13}C NMR spectroscopic analyses. The solubilities of CO{sub 2} in aqueous 10 mass % AHPD solutions were higher than those in aqueous 10 mass% MEA solutions above 4 kPa at 298.15 K, but lower below 4 kPa. The solubility difference between these two solutions increased with the CO{sub 2} partial pressures above the crossover pressure. Equilibrated CO{sub 2}-MEA-H{sub 2}O and CO{sub 2}-AHPD-H{sub 2} solutions at various CO{sub 2} partial pressures ranging from 0.01 to 3000 kPa were analyzed by {sup 13}C NMR spectroscopy. AHPD contains more hydroxyl groups than nonhindered MEA, and hence the chemical shifts in its {sup 13}C NMR spectra were strongly ...

2003-04-15

218

EVIDENCE FOR EVOLUTION AMONG PRIMORDIAL DISKS IN THE 5 Myr OLD UPPER SCORPIUS OB ASSOCIATION  

International Nuclear Information System (INIS)

Moderate-resolution, near-infrared spectra between 0.8 and 5.2 #mu#m were obtained for 12 late-type (K0-M3) disk-bearing members of the #approx#5 Myr old Upper Scorpius OB association using SpeX on the NASA Infrared Telescope Facility. For most sources, continuum excess emission first becomes apparent between #approx#2.2 and 4.5 #mu#m and is consistent with that produced by single-temperature blackbodies having characteristic temperatures ranging from #approx#500 to 1300 K. The near-infrared spectra for 5 of 12 Upper Scorpius sources exhibit Pa#gamma#, Pa#beta#, and Br#gamma# emission, indicators of disk accretion. Using a correlation between Pa#beta# and Br#gamma# emission line luminosity and accretion luminosity, mass accretion rates ( M-dot ) are derived for these sources that range from M-dot = 3.5x10"-"1"0 to 1.5 x 10"-"8 M_s_u_n yr"-"1. Merging the SpeX observations with Spitzer Space Telescope mid-infrared (5.4-37.0 ...

2010-11-01

219

The effect of patient shield position on gonad dose during lumbar spine radiography  

Energy Technology Data Exchange (ETDEWEB)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose ...

2010-05-15

220

The effect of patient shield position on gonad dose during lumbar spine radiography  

International Nuclear Information System (INIS)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any ...

2010-05-01

221

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination ...

1981-01-01

222

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of ...

2009-05-15

223

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...

1989-08-01

224

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...

1989-01-01

225

Sudden infant death syndrome and placental disorders: the thyroid-selenium link.  

Science.gov (United States)

Placental insufficiency, inducing hypoxia-ischaemia, is considered a major cause of neuronal injury and impaired post natal development. Placental insufficiency alters the metabolism of arachidonic acid and its oxidation products. Premature labour and low-birth-weight infants are associated with reduced intrauterine blood-flow and infections of the reproductive tract. Thyroidal activity is depressed in undernutrition (placental insufficiency). Premature infants require extra vitamin C for normal tyrosine metabolism (tyrosine is the thyroxine precursor). Among the symptoms indicating infantile cretinism, which appear during 3-5 months of age are: delayed union of skull bones, torpid behaviour, slow feeding, cyanosis during feeding, excessive sleepiness, enlarged tongue, umbilical herniation, flabby musculature, short stature and delayed development. These symptoms have all been described in low-birth-weight infants and sudden infant death syndrome victims by various ...

1997-04-01

226

Sinonasal malignant tumors involvement of the orbit and skull: a computed tomography study; Comprometimento orbito-craniano por tumores malignos sinonasais: estudo por tomografia computadorizada  

Energy Technology Data Exchange (ETDEWEB)

Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through the ethmoidal (70%) and orbital roof (30%). ...

2002-10-01

227

Effect of dose on lead retention and distribution in suckling and adult female mice  

International Nuclear Information System (INIS)

Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free "2"0"3Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age groups. Though uptake of lead into brain and into femur was observed to be directly related to dose over a wide ...

228

Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January through December 1984 were analized. 90 % of ...

1984-12-01

229

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features; Modificazioni anatomiche dopo chirurgia radicale e ricostruzione con lembi peduncolati o rivascolarizzati nei tumori cervico-facciali negli stadi avanzati: Aspetti con Tomografia Computerizzata e Risonanza Magnetica  

Energy Technology Data Exchange (ETDEWEB)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial flaps appeared as mostly fatty thickened layers with both imaging methods. Temporal and ...

1997-04-01

230

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features  

International Nuclear Information System (INIS)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial flaps appeared as mostly fatty thickened layers with both imaging methods. Temporal and ...

1997-01-01

231

Computed tomography whole body imaging in multi-trauma: 7 years experience  

International Nuclear Information System (INIS)

AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded prospectively. RESULTS: Over the 7-year ...

2006-04-01

232

Vacuum distillation refining and recycling of magnesium alloys  

Energy Technology Data Exchange (ETDEWEB)

Purification parameters of the vacuum distillation process for AM50A and AZ31B magnesium alloy were studied. The vacuum distillation tests were kept at 580 C to 620 C up to 10 h under a vacuum pressure of about 1 Pa. The purification ratio for AM50A magnesium alloy increases with increasing the purification time. The chemical compositions of materials deposited purifying at 580 C for AM50A magnesium alloy almost satisfy the values for pure magnesium specified by JIS standard specification. The chemical compositions of deposited materials at 600 C for AZ31B magnesium alloy satisfy the values specified by the standard specification except for Zn. (orig.)

2003-07-01

233

Sexual function in women receiving maintenance dialysis  

British Library Electronic Table of Contents (United Kingdom)

Abstract While substantial attention has been paid to the issue of sexual dysfunction in men on chronic dialysis, less is known about this problem in women with end-stage renal disease. We sought to assess sexual dysfunction in women on chronic dialysis and determine whether patients discuss this problem with their providers and receive treatment. We prospectively enrolled women receiving chronic hemodialysis or peritoneal dialysis in Pittsburgh, PA. We asked patients to complete the 19-item Female Sexual Function Index (FSFI) to assess sexual function and a 5-item survey that assessed whether patients had discussed sexual dysfunction with their providers and/or received treatment for this problem in the past. We enrolled 66 patients; 59 (89%) on hemodialysis and 7 (11%) on peritoneal dial...

2010-01-01

234

Safety designs for sludge ducts in brown coal briquetting plants  

Energy Technology Data Exchange (ETDEWEB)

Studies technological safety of installing a water spray pressure vessel between electrostatic dedusters and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption; about 8/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer.

1987-06-01

235

Safe design of mud ditches in briquetting factories  

Energy Technology Data Exchange (ETDEWEB)

The authors study technological safety of installing a water spray pressure vessel between electrostatic deduster and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption: about 8 m/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer. (MOS).

1987-06-01

236

Radon monitoring program, May-July 1980  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements at 50 locations in the monitoring network at Canonsburg, Pa., are reported for the quarterly period of April 29 to July 28, 1980. In addition, a summary of all data from the date of initiation of the network (covering the period January 29 to July 28, 1980) is presented for comparison purposes. Average background in the Canonsburg area for the quarterly period was 0.21 pCi/liter with a range of 0.16 to 0.26 pCi/liter. This compares with an average for the first quarter of 0.18 pCi/liter and a range of 0.12 to 0.23 pCi/liter. Concentrations ranging from 0.27 to 0.75 pCi/liter at 17 locations exceeded the background range. These locations are predominantly downwind of the site in an easterly direction. A similar pattern is evident from the summary of data for the first two quarters.

1980-12-10

237

Preparation and characterization of polyamide 6/polyethylene blend-clay nanocomposites in the presence of compatibilisers and stabilizing system  

British Library Electronic Table of Contents (United Kingdom)

Several compatibilising systems were added to high-density polyethylene (HDPE) and polyamide 6 (PA6) blends in the presence of an organically modified montmorillonite (OMM). All the blends were prepared by using a co-rotating twin-screw extruder and characterized by SEM, TEM and XRD analyses. In addition, the rheological behaviour and the mechanical properties - tensile and impact - were evaluated. The presence of OMM affects the dimensions of the polymeric phases in the blend but not their mutual adhesion, granted only by the compatibilisers. TEM, SEM and XRD analyses indicated that there is a strict correlation between the compatibilisation level and the final interlayer distance achieved by OMM. Even if some filled compatibilised blends showed a fairly good morphology - in terms of phas...

2010-01-01

238

Physical therapy for chronic pain conditions—A novel approach using mind–body connection  

British Library Electronic Table of Contents (United Kingdom)

The treatment of chronic pain conditions continue to present a challenge to the medical field. Physical therapy treatment needs to approach the management of chronic pain differently than the approach used to resolve acute pain. Patients with chronic pain often have many factors that have perpetuated the pain condition. These factors, as well as pain itself, influence their ability to reactivate and perform functional daily activities. Physical therapists can begin to address some of the factors, including fear and deconditioning, by building confidence and body awareness in a self-care model including a slow graduated reactivation program. There is evidence that patients with chronic pain conditions have altered motor control that may be influencing reoccurrences and possible flares of pa...

2011-01-01

239

Malignant transformation of diploid human fibroblasts by transfection of oncogenes  

Energy Technology Data Exchange (ETDEWEB)

This document consist of brief reports prepared by postdoctoral students supported by the project, each describing his accomplishments under the grant. Topics include (1) Malignant Transformation of MSU-1. 1 Cells by Gamma Radiation, (2) Correlation between Levels of ras Expression and Presence of Transformed Phenotypes Including Tumorigenicity, Using a Modulatable Promoter, (3) Relation between Specific rad Oncogene Expression, (4) Correlation of Genetic Changes in Fibroblastic Tumors with Malignancies, (5)Transformation of MSU-1.1 Cells by sis Oncogene, (6) Malignant Transformation of MSU-1.0 Cells, (7) Correlation of Urokinase Plasminogen Activation (mu-PA) with Malignant Phenotype, (8)Two Dimensional Gel Electrophoresis Studies of the Proteins of the Major Cell Strains of the MSU-1 Family of Cells, and (9) Correlation between Proteinase Activity Levels and Malignancy.

1992-01-01

240

Local mass transfer (heat transfer) between wall and fluid in a thin-film evaporator  

Energy Technology Data Exchange (ETDEWEB)

The measurement of local heat transfer coefficients is necessary to record the basic phenomena of heat transfer in thin-film apparatuses. For this reason the so-called electrochemical analogy method was developed and used for this application. The electrochemical method implies a specifically composed electrolyte which substitutes the fluid to be evaporated in the thin-film apparatus. Using the redox electrolyte (0,025 kmol/m/sup 3/ K/sub 4/Fe(CN)/sub 6/ resp. k/sub 4/Fe(CN)/sub 6/ and 2nNaOH) the viscosity was, for the first time, thickened until 0.4 Pa s by the help of hydroxyethyl-cellulose.

1983-03-01

241

Kinetics of carbon dioxide absorption in aqueous solutions of diisopropanolamine  

Energy Technology Data Exchange (ETDEWEB)

A bubble column absorber was used to investigate kinetics of the reaction between carbon dioxide and aqueous solutions of diisopropanolamine (DIPA), by means of gas absorption experiments. These were conducted in the temperature range of 10 to 40deg C, with DIPA concentrations from 5 to 500 mol/m{sup 3}, and CO{sub 2} partial pressures between 5 and 101 kPa. A model based on the Danckwerts' surface reneval theory was used to analyze the experimental results and to determine the rate constant. The obtained data support the assumption of a second-order overall reaction, with the rate constants being well correlated by the Arrhenius equation: k{sub 2} = 1.112 x 10{sup 10} exp(-4848/T). (orig.).

1992-04-01

242

Inhibition of heat shock protein 27 (HspB1) tumorigenic functions by peptide aptamers  

British Library Electronic Table of Contents (United Kingdom)

Human heat shock protein 27 (Hsp27, HspB1) is an anti-apoptotic protein characterized for its tumorigenic and metastatic properties, and now referenced as a major therapeutic target in many types of cancer. Hsp27 biochemical properties rely on a structural oligomeric and dynamic organization. Downregulation by small interfering RNA or inhibition with dominant-negative mutant have proven their efficiency to counteract the anti-apoptotic and protective properties of Hsp27. In this study, we report the isolation and characterization of Hsp27-targeted molecules interfering with its structural organization. Using the peptide aptamer (PA) strategy, we isolated PAs that specifically interact with Hsp27 and not with the other members of the small heat shock protein family. In mammalian cell cultur...

2011-01-01

243

Hydro cyclone. Dimensioning and operation; Hidrociclon. Dimensionado y operacion  

Energy Technology Data Exchange (ETDEWEB)

The hydro cyclone is a piece of equipment for separating and/or classifying solids/liquids with a wide variety of applications in different industrial sectors. This article describes the construction and operation of a hydro cyclone to verify the influence of the main size parameters and variables on its concentrating behaviour. The industrial-sized model which was built does not correspond exactly to the engineering designs. During operation, there was a load loss, which did not exceed 30 kPa, as a results of the fact that the suspension flow was unable to circulate with the original dimensions. However, when, for various reasons, the lower diameter was reduced, it proved possible to achieve an efficiency rate of over 95% in the concentration circuit. (Author) 23 refs.

2007-07-01

244

Household batteries: Evaluation of collection methods  

Energy Technology Data Exchange (ETDEWEB)

While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household batteries are ...

1992-01-01

245

Household batteries: Evaluation of collection methods  

Energy Technology Data Exchange (ETDEWEB)

While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in reclaiming household batteries are ...

1992-12-31

246

Hearing pathways and directional sensitivity of the beluga whale, Delphinapterus leucas  

British Library Electronic Table of Contents (United Kingdom)

Odontocetes are believed to receive sounds primarily through the pan bone region of the lower jaw although much variation in jaw morphology exists among species. In order to further examine this jaw hearing hypothesis we tested the head receiving sensitivity and directional hearing of a beluga whale, Delphinapterus leucas. Hearing thresholds were measured using auditory evoked potentials (AEPs). The subject proved to have highly directional hearing for far-field click stimuli similar to that of bottlenose dolphins and more directional than the harbor porpoise. For near-field jawphone stimulation, the beluga's lowest thresholds were found when click stimuli were presented at the rostrum tip (76?dB re: 1??Pa) although thresholds from the pan bone region stimulation were only 2?3?dB higher. S...

2008-01-01

247

Gamma-ray spectrometric analysis of nuclides formed in thorium by neutron irradiation  

International Nuclear Information System (INIS)

Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).

1985-02-01

248

Focused ion beam fabrication and properties of nanoscale Josephson junctions for sensors and other applications  

International Nuclear Information System (INIS)

The methods of superconducting device fabrication by lithography and multilevel processing usually require a number of processing steps with lithographic resolution and alignment adequate for the scale of the device be fabricated. As an alternative, the focused ion beam (FIB) microscope is increasingly being used directly to fabricate devices. A major advantage of using a FIB compared to other lithography methods is its flexibility and high resolution. It allows in-situ, milling (#propor to#5 nm at a beam current of 1 pA) to a variety of depths, and imaging (2 nm) of the sample. In this paper we describe our development of junction fabrication techniques using the FIB and their application in creating a range of potential sensor devices and quantum electronics applications. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2005-03-01

249

Experimental Study of Nucleate Pool Boiling of FC-72 on Smooth Surface under Microgravity  

British Library Electronic Table of Contents (United Kingdom)

Experiments of highly subcooled nucleate pool boiling of FC-72 with dissolved air were studied both in short-term microgravity condition utilizing the drop tower Beijing and in normal gravity conditions. The bubble behavior and heat transfer of air-dissolved FC-72 on a small scale silicon chip (10 ? 10 ? 0.5?mm3) were obtained at the bulk liquid subcooling of 41?K and nominal pressure of 102?kPa. The boiling heat transfer performance in low heat flux region in microgravity is similar to that in normal gravity condition, while vapor bubbles increase in size but little coalescence occurs among bubbles, and then forms a large bubble remains attached to the heater surface during the whole microgravity period. Thermocapillary convection may be an important mechanism of boiling heat transfer in ...

2011-01-01

250

Evaporation behavior of water and concentration of technetium and rhenium using thin film evaporator  

International Nuclear Information System (INIS)

The nuclear energy cycle requires the recycling of nuclear fuel, water, chemical reagents, and the volume reduction of radioactive liquid wastes. A fundamental technique for continuous recovery of water using a thin-film evaporator was examined. Appropriate recovery measurements were: an evaporator heat temperature of 323 K, a feed rate of 0.23 cm"3 x s"-"1, a vacuum pressure of 15 mmHg (2 kPa), and impeller rotational speeds of 500#approx#600 rpm (min"-"1). The concentration of trace technetium and rhenium in aqueous solutions was also studied. A decontamination factor of 10"5 for rhenium was obtained. (author)

1999-06-01

251

Efficacy of Azadirachta indica extracts against Boophilus microplus  

British Library Electronic Table of Contents (United Kingdom)

Extracts were prepared from leaf, bark, and seed of Azadirachta indica, leaf and seed of Prunus persica, bark of Mangifera indica, and leaf of Psidium guajava and were evaluated against Boophilus microplus. Of the eight extracts screened, the extracts prepared from the A. indica seed showed very high level of efficacy (80%) after 5?h of treatment. Besides the immediate effect on adult ticks, the egg-laying properties of the survived ticks was also assessed, and a significant reduction (P?A. indica seed extracts was noted in comparison to control. The efficacy of the neem seed extracts was compared with the commonly used synthetic pyrethroids, and comparable efficacy against B. microplus fed on animals treated with neem seed extracts and acaricide treated was noted. The possibility of using...

2008-01-01

252

Effect of treatment time on low temperature plasma nitriding of stainless steel by saddle field neutral fast atom beam source  

International Nuclear Information System (INIS)

Recent research carried out in laboratories showed that Saddle field neutral fast atom beam source is a promising method for nitriding of stainless steel. In the present work, the effect of treatment time on the microstructural and mechanical properties of plasma-nitrided stainless steel sample was investigated by this new method. Plasma nitriding was carried out at 420 deg. C and at a pressure of 0.1 Pa for a time range of 1 to 12 h. SEM-EDX, microhardness tests, optical microscopy and X-ray diffraction (XRD) were used to evaluate the mechanical and structural properties of the nitrided layer. It was found that nitriding time has a pronounced effect on the structural and mechanical properties of low-temperature plasma-nitrided samples and produced a precipitation-free thin hard nitrided layer within a short processing time.

2006-09-25

253

Dislocation structure and mechanical properties of. cap alpha. -iron in dependence on plastic deformation conditions  

Energy Technology Data Exchange (ETDEWEB)

Investigations of dislocation structure and mechanical properties of iron after rolling deformation in shaped rolls and after hydroextrusion are conducted. It is shown that dislocation iron structure slightly changes with deformation degree after rolling in shaped rolls and annealing and it is characterized by low density of screw dislocations. Cold brittleness temperature decreases in the result of rolling and the succeeding recrystallization and impact strength increases both at room temperature and at low temperatures. Screw dislocations having high Peierls barrier prevail in the structure after hydroextrusions. The iron deformed by hydroextrusion at 400 mPa and higher after annealing has high cold brittleness temperature and low impact strength.

1982-03-01

254

Development of ball bearings with solid film for high-vacuum, high-temperature, high-speed application  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the experimental results of long-life solid lubricated ball bearings tested under high-vacuum of 10 exp -4 Pa, high-temperature of 300 C, and high-speed (9000 rpm) conditions. For full ball-type bearings, the thin soft metals, either Ag or Pb, which were coated on the races and balls, appeared to have good torque properties. However, the durability of such bearings was less than 300 hours. The transfer films from the lamellar solid MoS2 and metal composite retainers improved the torque and wear properties. For ceramic, i.e., silicon nitride, balls used with steel rings, wear occurred on the inner rings. All ceramic bearings with composite retainers showed improved torque and wear properties. 18 refs.

1993-04-01

255

Comparative environmental performance of semi-trailer load boxes for grain transport made of different materials  

British Library Electronic Table of Contents (United Kingdom)

Background, aim, and scope Semi-trailers with load boxes are the most important mode of grain transport by land in the world. Load boxes can be produced with different materials such as: wood, steel, and synthetic material. They are responsible for effectiveness retention and quality of grains during the transport. Among the main aspects to be considered and valued when selecting materials for load boxes are the final mass of the semi-trailer, loss of grains, and mechanical properties. Environmental performance is another important aspect to be taken into account for developing and selecting new materials in this kind of application. This study presents a comparative environmental evaluation of load boxes built from two different materials (a wood panel and a three-layer synthetic (TLS) pa...

2010-01-01

256

Cleaning of flue gases from cupola and electric steel melting furnaces in ''Ural'' rotoclones  

Energy Technology Data Exchange (ETDEWEB)

A highly effective and economical apparatus was developed by the All-Union Scientific Research Institute for Energy and Nonferrous Metallurgy for cleaning waste gases from cupola and electric arc steel melting furnaces --- the ''Ural'' rotoclone, which has been successfully introduced in many enterprises. Research results are presented for the efficiency of operation of these aggregates on equipping them on cupola and electric furnaces. With a 2 kPa aerodynamic resistance of the rotoclone the flue gas of the cupola furnace is cleaned to the sanitary standard. Highly effective collection of sublimates and aerosols from the electric arc furnace takes place with a ''Ural'' rotoclone aerodynamic resistance

1981-01-01

257

Characterization of focused-ion-beam-induced damage in n-type silicon using Schottky contact  

International Nuclear Information System (INIS)

The effects of focused-ion-beam-induced damage on electrical properties of n-type Si are investigated by Schottky contacts. Crystalline Si is exposed to 10-30 keV focused ion beam (FIB), followed by Pt deposition under vacuum of 4x10"-"4 Pa. From current-voltage-temperature measurements, barrier heights of the Schottky contacts are found to increase almost linearly as the FIB energy increases, with the maximum increment of 0.29 eV. The increase is suggested to be related to the arising of acceptorlike defects and an amorphous layer due to FIB damages. A theoretical model is set up to quantitatively describe the barrier height changes.

2006-04-10

258

Care programmes and integrated care pathways  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The article discusses how care programmes and integrated care pathways can be linked, finding ways to improve healthcare process professional and logistical quality from a supply chain and a network point-of-view. Design/methodology/approach - The authors argue that owing to cost containment goals and increasing healthcare demand, healthcare services systems are challenged to improve service quality, whilst at the same time finding ways to improve delivery processes. It explores if the combination of two instruments, care programmes and integrated care pathways, can meet both goals. This combination is illustrated by an example from the Institute of Mental Health Care Eindhoven en de Kempen. Findings - Analysis suggests that care programmes can be combined with integrated care pa...

2008-01-01

259

Calculation of temperature fields of and stresses in a hot steam generator collector for a WWER-440 reactor  

International Nuclear Information System (INIS)

Non-design-basis transition changes in the level fluctuations in the surrounds of a hot steam generator collector for a WWER-440 reactor and the corresponding responses of the temperature fields, strains and stresses are examined. A new approach to the thermal calculation of the horizontal steam generator, which is rapid and affords accurate results, is suggested. An important result of the calculation is the shape of the transition region level and the corresponding distribution of the heat transfer coefficient values. This was used for the calculation of the temperature fields, strain and stress of the hot collector. The stress values obtained were deeply below the yield point of the hot collector material but they get superimposed on the stress from overpressure in the primary and secondary circuits. The obtained fluctuations of the secondary medium level in the surrounds of the hot collector give rise to comparison stresses whose values are not negligible. ...

1989-01-01

260

Angiopoietin Balance in Septic Shock Patients With Acute Lung Injury: Effect of Direct Hemoperfusion With Polymyxin B-Immobilized Fiber  

British Library Electronic Table of Contents (United Kingdom)

Abstract Acute lung injury (ALI) in sepsis is characterized by an increase in microvascular permeability, resulting in pulmonary edema. Several studies have suggested that angiopoietin-1 and -2 play a contributory role in the pathogenesis of ALI. Polymyxin B-immobilized fiber column hemoperfusion is effective for sepsis-induced ALI. We investigated the angiopoietin levels before and after direct hemoperfusion with polymyxin B-immobilized fiber column (PMX) therapy. Enzyme-linked immunoassay was used to measure the serum angiopoietin-1 and -2 levels in 25 patients with septic shock treated with PMX. Eleven of the 25 patients were diagnosed with ALI. There was a significant positive correlation between the angiopoietin-1 level and the PaO2/FiO2 ratio, but there was a significant inverse corr...

2011-01-01

261

Vapor fraction measurements in a steam-water duct at atmospheric pressure using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure vapor fractions in a steam-water duct at atmospheric pressure. This unique experimental technique offers one the opportunity to observe and record on videotape now Patterns and transient behavior of two-phase flow inside opaque containers without perturbing the environment. The neutron radiographic technique is non-intrusive and requires no special transparent window region. Data are recorded simultaneously over a large area of interest. Image processing of the video data can be employed to measure bubble velocities and time-averaged and Instantaneous vapor fractions.

1994-11-11

262

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy  

International Nuclear Information System (INIS)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).

263

Sex determination using discriminant function analysis in children and adolescents: a lateral cephalometric study  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study is to test the validity of sex determination in children and adolescents using lateral radiographic cephalometry and discriminant function analysis. Fifty male and 50 female cephalograms of Taiwanese children were used (males and females with mean age of 15.52???1.38 and 15.67???1.54?years, respectively). Twenty-two cephalometric measurements were performed using computerized cephalometry. Statistical analysis shows that all measurements were sexually dimorphic (p?

2010-01-01

264

Revisited the mathematical derivation wall thickness measurement of pipe for radiography  

Energy Technology Data Exchange (ETDEWEB)

Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to ...

2007-07-01

265

Retinue of the beans roots growth by using neutron radiography technique  

International Nuclear Information System (INIS)

Agricultural practices frequently cause the development of a soil compacted layer below the surface. These compacted layers restrict the root penetration into deeper layers of soil, in search for water. It is proposed to monitor, using Non Destructive Test, the roots growth due to the planting of standard seeds in different agricultural soils, in function of their compactness and humidity. It will be used the neutrons beams derived from an irradiation channel called J-9 of the Reactor Argonauta (IEN/CNEN), so that the neutron radiographic images of the soil-plant system can be obtained. Each root can be evaluated for its ability to penetrate into compacted soil layers; this fact would mean an optimization of agricultural harvests. (author)

2002-08-11

266

Removal of scattered thermal neutrons using antiscatter grid  

International Nuclear Information System (INIS)

One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.

2006-12-01

267

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

268

Orthognathic treatment case after severe root resorption in the early treatment stage  

British Library Electronic Table of Contents (United Kingdom)

This article presents an orthognathic treatment case after severe apical root resorption of maxillary anterior teeth using anterior segmental osteotomy. This case involved a 20-year-old female with the chief complaint of maxillary protruding and irregularly aligned mandibular anterior teeth. Her medical history showed no allergies or medical problems. The overbite was +3.0mm, and the overjet +3.0mm. After extraction of the four first premolars, a multi-bracket treatment was started. A severe root resorption of the maxillary anterior teeth was found 12 months after active treatment. The maxillary anterior segmental osteotomy was chosen as the compensatory treatment. The total treatment period was 2 years and 7 months. The post-retention panoramic radiograph showed no developmental root reso...

2009-01-01

269

Neutron radiography with the cyclotron, 5. Cyclotron-based real time neutron fluoroscopy system and its application for some industrial components  

Energy Technology Data Exchange (ETDEWEB)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.

1987-03-01

270

Imaging automation and volume tomographic visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-07-01

271

Functional and Oncologic Outcomes of Partial Adrenalectomy for Pheochromocytoma in Patients With von Hippel-Lindau Syndrome After at Least 5 Years of Followup  

British Library Electronic Table of Contents (United Kingdom)

PurposeAlthough the safety and feasibility of partial adrenalectomy in patients with von Hippel-Lindau syndrome have been established, long-term outcomes have not been examined. In this study we evaluate the recurrence and functional outcomes in a von Hippel-Lindau syndrome cohort treated for pheochromocytoma with partial adrenalectomy with a followup of at least 5 years. Materials and MethodsWe reviewed the records of patients with von Hippel-Lindau syndrome treated with partial adrenalectomy for pheochromocytoma at the National Cancer Institute. Demographic, germline mutation status, surgical indication, oncologic and functional outcome data were collected. Local recurrence was defined as radiographic evidence of recurrent tumor on the ipsilateral side of partial adrenalectomy. Patients ...

2010-01-01

272

Five-year Changes in Periodontal Parameters after Apical Surgery  

British Library Electronic Table of Contents (United Kingdom)

IntroductionMost clinical studies on the outcome of apical surgery concentrate on periapical healing based on radiographic and clinical characteristics (signs and symptoms). This study focuses on long-term changes in periodontal parameters after apical surgery. MethodsPeriodontal parameters (ie, probing depth [PD], level of gingival margin [GM], and calculated clinical attachment level [CAL]) were collected at baseline and at 1 and 5 years after apical surgery. Changes in PD, GM, and CAL were calculated over time and were also evaluated in relation to patient-, tooth-, and treatment-related covariables. ResultsOne hundred eighty-six of 242 initially identified teeth could be evaluated. Significant changes in GM and CAL were observed at facial sites during the first year after surgery (mean...

2011-01-01

273

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

274

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-12-01

275

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-01-01

276

Case?control study of knee osteoarthritis and lifestyle factors considering their interaction with physical workload  

British Library Electronic Table of Contents (United Kingdom)

Aims The aim of this study is to examine the dose?response relationships between age, ?lifestyle factors?? (body mass index, tobacco smoking, sports), and symptomatic knee osteoarthritis in a population-based case?control study. Additionally, the study aims to investigate the mode of interaction between body mass index (BMI) and physical workload (occupational kneeling/squatting and lifting/carrying of loads) with respect to the risk of symptomatic knee osteoarthritis. Methods In five orthopedic clinics and five practices, 295 male patients aged 25?70 with radiographically confirmed knee osteoarthritis associated with chronic complaints were recruited. The control group comprised 327 male control subjects. In a structured personal interview, body weight at different ages, body height, cumu...

2010-01-01

277

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia  

International Nuclear Information System (INIS)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.

1999-04-01

278

Acute femoral neck fracture  

International Nuclear Information System (INIS)

Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).

279

Abces du muscle iliopsoas : complication rare de la sacro-iliite a pyogene chez lenfant  

British Library Electronic Table of Contents (United Kingdom)

Pyogenic sacroiliitis is a rare entity in children. Diagnosis is often delayed because of its variable clinical presentation, low suspicion by the examining physician, and rare findings on radiographs. Delayed diagnosis, however, results in complications such as iliopsoas abscess. We report the case of a 12-year-old girl hospitalized with a 21-day history of fever, pain in the left iliac fossa, and flexion contracture of the hip. On examination, she had fever (38.9 ^oC), psoitis, localized tenderness at the left sacroiliac joint, and pain elicited by lateral compression of the pelvis. The abdominal examination was normal. The erythrocyte sedimentation rate was 130mm in the first hour, C-reactive protein was 186mg/l, and the white blood cell count was 18,400/mm^3, with 79% neutrophils. Urin...

2010-01-01

280

A retrospective study of canine hip dysplasia in 116 military workingn> dogs. Part II: Clinical signs and performance data.  

Science.gov (United States)

The progression of hip dysplasia was investigated in 116 military working dogs. Medical records were reviewed for any clinical history of hind-limb lameness. Pelvic radiographs were studied for evidence and degree of hip dysplasia, degenerative joint disease, or both. The number of months each dog worked was determined. Each dog's age at termination from service and cause of death (or euthanasia) were recorded. The mean months of work for normal and dysplastic dogs were evaluated using the Student's t-test. No significant difference was found in the total number of months worked between normal and dysplastic dogs (p greater than 0.05). PMID:8875358

281

A retrospective study of canine hip dysplasia in 116 military workingn> dogs. Part I: Angle measurements and orthopedic foundation for animals (OFA) grading.  

Science.gov (United States)

The progression of hip dysplasia was investigated in 116 military working dogs. Serial pelvic radiographs were graded for degree of dysplasia and degenerative joint disease (DJD). Norberg angles, angles of inclination, and joint space widths were measured. There was a significant correlation between the Norberg angle and the degree of dysplasia (p less than 0.0001). Angles of inclination and joint space width measurements did not demonstrate a correlation to canine hip dysplasia. Dysplastic dogs had a significant estimated risk for development of DJD compared to normal dogs (p less than 0.0001; odds ratio of 70.2). Dogs with normal hip conformation at 24 months of age or older did not develop moderate nor severe DJD. PMID:8875357

282

CT assessment of thoracic gunshot wounds. Our personal experience; Ruolo della Tomografia Computerizzata nelle lesioni da arma da fuoco del torace. Esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

CT is a valuable tool in assessing thoracic gunshot wounds. CT is also the method of choice in emergency, because it permits rapid depiction of bullet damage to the chest and to other body districts. This in turn permits correct assessment of the main thoracic injuries, plus adequate and prompt planning of surgical treatment or support intensive care. It is reported on the role of CT in diagnosing the complex pleuropulmonary, cardiovascular and thoracic wall injuries caused by gunshot wounds, with their specific and acute signs which differ greatly fro those of other types of chest trauma. In the last 4 years, it was observed an amount of 76 cases of gunshot injury, twenty-six of them involved the chest. The patients, 25 men and 1 woman (mean age: 32 years, range: 17-48), were all submitted to emergency CT with iv contrast agent injection and the CT-angiography technique. The reanimator was always presented to monitor the patients' vital functions and shock state. CT of the ...

1999-11-01

283

Gunshot wounds to the head. Correlations between CT and clinical findings, neurosurgical treatment and long-term sequels; Traumi cranio-encefalici da proiettile: correlazione tra tomografia computerizzata, clinica, trattamento neurochirurgico e sequele a distanza  

Energy Technology Data Exchange (ETDEWEB)

With the aim of demonstrating the usefulness of computerised tomography (CT) findings in the planning of brain neurosurgery in gunshot victims, for prompt and successful treatment, 30 patients with brain gunshot wounds were examined with CT over 5 years. The mortality rate of firearm wounds of the skull base was 34% higher than that of the hemisphere; this is due to carotid hemorrhage and midbrain damage. Such traumas require emergency radiological diagnosis and neurosurgical treatment because of their severity and early irreversible complications. Complex operations and skilled surgeons may prevent disabling postoperative sequels. CT findings are indispensable and must be correctly interpreted. The radiologist and the neurosurgeon must collaborate closely and both must consider several diagnostic factors affecting surgical planning. [Italian] Scopo dello studio e' stato quello di dimostrare l'utilita' della semeiologia della tomografia ...

2000-03-01

284

Reprocessing of research reactor spent nuclear fuel at the PA ''Mayak''  

International Nuclear Information System (INIS)

The first Russian reprocessing facility, known as RT-1 (located at PA-Mayak in Ural region) was started on the radiochemical plant base in 1977. Nowadays RT-1 is the sole operating reprocessing plant in Russia. The main features of RT-1 is its broad spectrum of reprocessing spent nuclear fuels (SNF). The following spent fuel types are reprocessed: -) SNF from PWR reactors (WWER-440) and FB reactor (BN-600); -) SNF of transport ship reactors; -) production reactors SNF; -) research reactor spent nuclear fuel. The world-known technological processes are used at RT-1, but there are the following distinctive features. First, the universality of the three technological lines which allows not only the reprocessing of various SNF kinds, but also to implement the combined reprocessing of some types of them. Secondly, extraction of neptunium during SNF reprocessing which is used to implement its separate storage and for radioisotope production. Thirdly, target enrichment of ...

2007-03-11

285

Reprocessing of research reactor spent nuclear fuel at the PA 'Mayak'  

Energy Technology Data Exchange (ETDEWEB)

The first Russian reprocessing facility, known as RT-1 (located at PA-Mayak in Ural region) was started on the radiochemical plant base in 1977. Nowadays RT-1 is the sole operating reprocessing plant in Russia. The main features of RT-1 is its broad spectrum of reprocessing spent nuclear fuels (SNF). The following spent fuel types are reprocessed: -) SNF from PWR reactors (WWER-440) and FB reactor (BN-600); -) SNF of transport ship reactors; -) production reactors SNF; -) research reactor spent nuclear fuel. The world-known technological processes are used at RT-1, but there are the following distinctive features. First, the universality of the three technological lines which allows not only the reprocessing of various SNF kinds, but also to implement the combined reprocessing of some types of them. Secondly, extraction of neptunium during SNF reprocessing which is used to implement its separate storage and for radioisotope production. Thirdly, target enrichment of ...

2007-07-01

286

Purification of CH{sub 3}Cl from CH{sub 3}I using cold trap with sealed 2,2,4-trimethylpentane for {delta}{sup 37}Cl measurement  

Energy Technology Data Exchange (ETDEWEB)

A cryogenic separation method of chloromethane (CH{sub 3}Cl) from methyl iodide (CH{sub 3}I) for {delta}{sup 37}Cl measurement with isotope ratio mass spectrometer is described. A cold trap with sealed 2,2,4-trimethylpentane (TMP) as the cryogen is used in this method. CH{sub 3}Cl can be separated from CH{sub 3}I at the TMP melting point (-107 deg. C) based on the difference in the vapor pressure between CH{sub 3}Cl (322.6 Pa) and CH{sub 3}I (lower than 1.3 Pa) at -107 deg. C. After two-step separation processes, the yields of CH{sub 3}Cl purified from CH{sub 3}Cl-CH{sub 3}I mixture are 96-101%, and the difference between the {delta}{sup 37}Cl{sub original} and {delta}{sup 37}Cl{sub Afterseparation} is from -0.06 to +0.06 per mille (0.01 {+-} 0.04 per mille ). These results suggest that CH{sub 3}Cl is completely separated from CH{sub 3}I with no change of {delta}{sup 37}Cl value. This method using the cold trap with sealed TMP is very safe and ...

2006-01-05

287

Liquid radwaste processing with spiral wound reverse osmosis  

International Nuclear Information System (INIS)

Two different reverse osmosis systems were investigated. The first was a 50-element plant-scale system that is used to treat 2200 m"3 of AECL liquid radwastes annually.It uses thin-film composite (TFC) membranes and operates at an applied pressure of 2760 kPa, with a fixed crossflow of about 40 L/min. The other system uses the same thin-film composite membranes for waste processing but is a two-element pilot-scale system. It is operated at pressures m ranging between 1500 and 7000 kPa, at a fixed crossflow of 55 L/min. The average lifetime of the thin-film composite membranes in the plant-scale processing application at AECL is about 3000 h. After this service life has expired the rejection efficiency declines rapidly from 99.5% to about 95% as the membranes become impaired from chemical cleaning procedures that are required after each 100 m"3 of waste is treated. The permeation flux for the plant-scale system decreases from about 2.2 ...

1996-02-25

288

Laboratory tests on the effects of partial embedment on soil-structure interaction (embedment effect test on soil-structure interaction)  

International Nuclear Information System (INIS)

A series of Model Tests of Embedment Effect on Reactor Buildings has been carried out by the Nuclear Power Engineering Corporation (NUPEC), under the sponsorship of the Ministry of International Trade and Industry (MITI) of Japan. Reactor buildings in Japan are partially embedded in general. Therefore, it is important to know how partial embedment affects the vibration characteristics of reactor buildings relating to seismic safety. Laboratory tests were conducted using a ground model made of silicone rubber (Young's modulus 2.3x10"6 Pa, Poisson's ratio 0.484, Density 1.24x 10"3 kg/m3 , Damping ratio 0.01) and a foundation model made of aluminum shown to study the effects of embedment on soil-structure interaction with different backfill types. The ground model is a cylinder, 70 cm high and 300 cm in diameter, with pit where the parallelepiped foundation model with square plan of 30 cm x 30 cm and 18 cm high was placed. Four types of backfill of silicone rubber ...

1993-08-15

289

Influence of sedation and data acquisition method on tracer uptake in animal models: ["1"2"3I]-2-iodo-L-phenylalanine in pentobarbital-sedated tumor-bearing athymic mice  

International Nuclear Information System (INIS)

Objectives: To minimize movement artifacts during tracer imaging studies, the animals are generally sedated. Although many reports describe the effect of barbiturates on brain function, less is published about the general impact on the extracerebral metabolism and tracer biodistribution. This report describes the influence of pentobarbital on tumor uptake of ["1"2"3I]-2-iodo-L-phenylalanine (["1"2"3I]-2I-L-PA) using dissection and nuclear imaging. Methods: R1M tumor-bearing athymic mice were divided into two populations: untreated and pentobarbital-treated. Each group was subjected to dynamic and static planar imaging and organ dissection after ["1"2"3I]-2I-L-PA injection. Two-compartment blood modeling was performed. Analysis of variance (ANOVA), t test and clustered boxplot analyses were used to compare the results between the treatment groups and between the data acquisition methods. Results: Two-compartment blood modeling demonstrated that ...

2006-01-01

290

Design of a 60 MW CFB gasification system (CGAS) for Uganda : utilising rice husks as input fuel  

Energy Technology Data Exchange (ETDEWEB)

In Uganda, biomass comprises more than 95 per cent of the total energy supply. Agricultural residues are a major source of energy that can be converted into producer gas in biomass gasifiers. The high poverty levels in Uganda can be attributed in part to the fact that more than 90 per cent of the population does not have access to electricity due to limited and unreliable electricity produced in the country. A circulating fluidized bed (CFB) gasification system was designed in this study in order to generate a system for the effective use of agricultural wastes for energy production. Rice husks were used as the feedstock for a power output of 60 MW. The gasification system was designed using ERGUN CFB software with available theoretical and experimental data. The design comprises a reactor subsystem, air distribution plate, cyclone, air inlet and fuel feeding systems. The reactor is 10 m high and has a fuel flow rate of 8.1 kg/s. The inlet air flow rate is 11 m{sup 3}/s and the ...

2010-07-01

291

A study on the recovery of radiation hardening of PWR pressure vessel steel using microhardness and positron annihilation  

International Nuclear Information System (INIS)

A post-irradiation annealing study was conducted with use of reactor pressure vessel(RPV) steel A533B C1.1 base metal irradiated to a dose of 4.84x10"1"8 n/cm"2 at about 380 deg C. Microhardness and positron annihilation (PA) methods were used to obtain better understanding of the recovery of radiation hardening. Isochronal anneal experiments indicated that two recovery processes occur during annealing of irradiated specimens. The first recovery process occurs in the temperature of 280-305 deg C. The variations of Ip, Iw and R parameters indicated that the formation of vacancy clusters by vacancy aggromeration and the annihilation parameters measured indicated that the dissolution of carbon atoms decorated around vacancy-type defects and possible precipitates, and the annihilation of monovacancies give rise to the second recovery process. It was further indicated that radiation anneal hardening (RAH) in the range of 305-405 deg C between the temperature ranges for ...

292

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 8. Strahlendosen beim thorakoabdominalen babygramm und bei der abdomenaufnahme neugeborener und saeuglinge  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen ...

2010-06-15

293

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants  

International Nuclear Information System (INIS)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could ...

2010-06-01

294

Health-hazard evaluation report HETA 88-108-2146, Asarco New Market/Young Mines, Mascot, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

In response to a request from the International Chemical Workers Union, Akron, Ohio, an investigation was made into possible hazardous working conditions at two American Smelting and Refining Company (SIC-1031) zinc mines (New Market and Young) in Mascot, Tennessee. Specifically, exposures to asbestos (1332214), silica (14808607), and diesel emissions were determined. At both mines overexposures were found to nitrogen-dioxide (10102440) (NO2) and coal-tar pitch volatiles. Twenty-four percent of the NO2 measurements taken were above the NIOSH recommended ceiling of 1 part per million (ppm), but none exceeded the Mine Safety and Health Administration's (MSHA) ceiling of 5ppm. Exposure to diesel particulates ranged from 0.24 to 1.06mg/cu m. None of the 52 respirable dust samples collected exceeded the calculated MSHA limits for free silica exposure. A medical evaluation was offered and 83 of the 400 current employees and one retired employee participated. Seven underground ...

1991-10-01

295

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

Energy Technology Data Exchange (ETDEWEB)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the ...

1987-04-01

296

Early detection of damage and analysis of damage development in metal structural components. Schaedigungsfrueherkennung und Schadensablauf bei metallischen Bauteilen  

Energy Technology Data Exchange (ETDEWEB)

The topics of these short lectures on the subject of cyclic stress were: Microstructural mechanisms of damage accumulation under a multistage cyclic stress until incipient cracking; influence of surface decarbonizing phenomena on the failure behaviour of steel construction parts subjected to cyclic stress; thermocyclic fatigue of pipe samples of austenitic steel 1.4436; studies on surface structuring, microstructure and fatigue in LCF area. The short lectures on effects of quasi-static and creep stress were: Shear fracture in AlMg alloys as a result of local plastic instability; study of formation and growth of pores for an early recognition of damage and the course of damage in heat-resistant steels under creep test; experimental and numeric studies of the infuence of the microstructure on the course of damage during shear fractures of steel; numerical modelling of ductile fractures on the basis of micromechanical models. Under the topic of tribological stress the following lectures ...

1989-01-01

297

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have been well without ...

2008-04-15

298

Computed tomography in the diagnosis of cavum septum pellucidum  

Energy Technology Data Exchange (ETDEWEB)

The cavum septum pellucidum is an anatomical variants of the septum pellucidum, and lying between two lateral ventricles and this is referred to as the fifth ventricle. Occasionally, posterior extension of the cavum septum pellucidum towards the splenium is seen and this is known as the cavum vergae, or sixth ventricle. The septum is double membrane and occasionally a narrow cavity containing CSF is present between these membrane. The roof of the cavum septum pellucidum is formed by the corpus callosum and its floor by the anterior pillars of the fornix. This cavum outlined with air is occasionally seen in the pneumoencephalography. Brain CT scans of 1000 patients were performed, and the diagnosis could be made on the basis of the characteristic shape, density and location. Other diagnostic procedure are not necessary in these cases. Patients were examined with CT scanner from June-80' to Dec-80', at department of radiology, Maryknoll Hospital, and 13 cases were ...

1981-09-15

299

Comparative adequacy of conventional radiography, ultrasonography and Computed Tomography in twenty-six consecutive patients with acute superior mesenteric ischemia  

International Nuclear Information System (INIS)

Ischemic bowel disease is a rare disorder whose incidence is increasing as the mean age of the population increases. Diagnosis by clinical, laboratory and radiologic means is often difficult, and delay in definitive therapy results in substantial morbidity and mortality. A series of 26 consecutive patients, with proved acute superior mesenteric ischemia, was retrospectively reviewed: the authors reports the diagnostic methods performed preoperatively, the site and the cause of infarction and the time passed between the first radiograph and surgery. Plain abdominal radiographs were performed in 25 of 26 patients, screening abdominal US in 23 cases and CT in 19 cases. All radiological examinations were retrospectively reviewed by the three authors, independently, to recognize the different signs of infarction. On plain abdominal films, the findings warranting a presumptive diagnosis of bowel infarction were air-fluid levels (84% of cases), ...

1997-01-01

300

Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup  

International Nuclear Information System (INIS)

Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any ...

2009-02-01

301

Bone age estimation and prediction of final height in patients with {beta}-thalassaemia major: a comparison between the two most common methods  

Energy Technology Data Exchange (ETDEWEB)

Thalassaemic patients are in need of frequent assessment of bone age because of growth failure and pubertal disorders. To compare the ''rapid'' Greulich and Pyle (G and P) method with the third edition of the Tanner and Whitehouse (TW3) method for determining skeletal maturity and predicting final height in thalassaemic patients. A total of 191 radiographs from 58 patients (28 male, 30 female) were retrospectively evaluated by two investigators, one for each method. In 47 radiographs from 15 patients having attained their adult height, predicted final height was calculated according to each method. The mean bone ages determined by both the G and P and TW3 methods were lower than mean chronological age, although the differences were not statistically significant (10.04 {+-} 3.69 years and 9.98 {+-} 3.39 years vs. 10.78 {+-} 3.96 years, respectively). Both methods had a tendency to over-estimate final height. ...

2007-12-15

302

Assessment of arterial tumor vascularity in small hepatocellular carcinoma. Comparison between color Doppler ultrasonography and radiographic imagings with contrast medium: dynamic CT, angiography, and CT hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and 33.3%, respectively) in ...

2000-10-01

303

CT in the study of thoracic-pulmonary complications after liver transplantation; La Tomografia Computerizzata nello studio delle complicanze toraco-polmonari dopo trapianto del fegato  

Energy Technology Data Exchange (ETDEWEB)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the ...

2000-12-01

304

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 by the irradiation. From these results we can find that irradiation with the X-ray ...

305

Turnover of texture in low rate sputter-deposited nanocrystalline molybdenum films  

International Nuclear Information System (INIS)

The crystallite size and orientation in molybdenum films prepared by magnetron sputtering at a low rate of typical 1 (angstrom)s and a pressure of 0.45 Pa was investigated by X-ray diffraction and texture analysis. The surface topography was studied using atomic force microscopy. Increasing the film thickness from 20 nm to 3 microm, the films show a turnover from a (110) fiber texture to a (211) mosaic-like texture. In the early state of growth (20 nm thickness) the development of dome-like structures on the surface is observed. The number of these structures increases with film thickness, whereas their size is weakly influenced. The effect of texture turnover is reduced by increasing the deposition rate by a factor of six, and it is absent for samples mounted above the center of the magnetron source. The effect of texture turnover is related to the bombardment of the films with high energetic argon neutrals resulting from backscattering at the target under oblique ...

1997-04-04

306

The influence of active screen plasma nitriding parameters on corrosion behavior of a low-alloy steel  

Energy Technology Data Exchange (ETDEWEB)

This work presents a comparative study of low-alloy steel nitriding for different possible techniques. Active screen plasma nitriding (ASPN) is a successful surface modification method that has many advantages over the conventional DC plasma nitriding (CPN). The corrosion behavior of 30CrNiMo8 low-alloy steel has been examined using anodic polarization tests in 3.5% NaCl solution under varying conditions of ASPN and CPN processes. The process variables included active screen setup parameters, treatment temperature (550 and 580 deg. C), gas mixture (25/75 and 75/25 of N{sub 2}/H{sub 2}) and treatment time (5 and 10 h) in 500 Pa pressure. The structure and phases composition of the compound layer was studied by X-ray diffraction (XRD), microhardness tests, optical microscopy and scanning electron microscopy (SEM). It was observed that ASPN treated samples surface enhanced corrosion resistance while the temperature and/or hole size of screen setup increased.

2009-09-18

307

The influence of active screen plasma nitriding parameters on corrosion behavior of a low-alloy steel  

International Nuclear Information System (INIS)

This work presents a comparative study of low-alloy steel nitriding for different possible techniques. Active screen plasma nitriding (ASPN) is a successful surface modification method that has many advantages over the conventional DC plasma nitriding (CPN). The corrosion behavior of 30CrNiMo8 low-alloy steel has been examined using anodic polarization tests in 3.5% NaCl solution under varying conditions of ASPN and CPN processes. The process variables included active screen setup parameters, treatment temperature (550 and 580 deg. C), gas mixture (25/75 and 75/25 of N_2/H_2) and treatment time (5 and 10 h) in 500 Pa pressure. The structure and phases composition of the compound layer was studied by X-ray diffraction (XRD), microhardness tests, optical microscopy and scanning electron microscopy (SEM). It was observed that ASPN treated samples surface enhanced corrosion resistance while the temperature and/or hole size of screen setup increased.

2009-09-18

308

The cascade of reservoirs of the ``Mayak`` Plant: Case history and the first version of a computer simulator  

Energy Technology Data Exchange (ETDEWEB)

The improvement of the ecological conditions at waste storing reservoirs is an important task of the restoration activity at Production Association (PA) ``Mayak`` (South Urals). The radionuclides mostly {sup 90}Sr, {sup 137}Cs, and chemical pollutants deposited in the reservoir water and in the bottom sediment are very dangerous sources for the contamination of Techa River below the reservoirs and the contamination of groundwater in the surrounding formations. The spreading of radioactive contaminants has both hydrogeological and the chemical features. The thermodynamic approach used to account for physical-chemical interactions between water and the bed rocks based on Gibbs free energy minimization of multicomponent system (H-O-Ca-Mg-K-Na-S-Cl-C-Sr) permitted the authors to calculate the corresponding ionic and complex species existing in the solutions, and to characterize the processes of precipitation and dissolution. The model takes into account the input and ...

1994-07-01

309

Support effects on CO hydrogenation over Ru/zeolite catalysts  

Energy Technology Data Exchange (ETDEWEB)

Hydrogenation of carbon monoxide at 101.3 kPa has been studied over a series of ion-exchanged Ru catalysts supported on NaX, NaY, KL, Na mordenite, and HY zeolites. The type of zeolite had pronounced effects on the activity and selectivity of the Ru. The specific activity would appear to be related to the dispersion of reduced ruthenium in the zeolite. Methane selectivity, however, seems to be strongly influenced by the type and concentration of alkali cations remaining in the ion-exchanged zeolite. These cations appear to promote chain growth much as traditional alkali promoters would, though perhaps more indirectly. Due to bifunctional properties of the zeolite-supported catalysts, a significant fraction of C/sub 4/ was in the form of isobutane. Formation of isobutane seems to be related to either the Si/Al ratio in the zeolites or the concentration of the remaining alkali cations, but not to the OH concentration. In addition, H/sub 2/ chemisorption at 25/sup 0/C ...

1984-02-01

310

Summary of comments received from workshops on radiological criteria for decommissioning  

Energy Technology Data Exchange (ETDEWEB)

The Nuclear Regulatory Commission (NRC) is conducting an enhanced participatory rulemaking to establish radiological criteria for site cleanup and decommissioning of NRC-licensed facilities. Open public meetings were held during 1993 in Chicago, IL, San Francisco, CA, Boston, MA, Dallas, TX, Philadelphia, PA, Atlanta, GA, and Washington, DC. Interested parties were invited to provide input on the rulemaking issues before the NRC staff develops a draft proposed rule. This report summarizes 3,635 comments categorized from transcripts of the seven workshops and 1,677 comments from 100 NRC docketed letters from individuals and organizations. No analysis or response to the comments is included. The comments reflect a broad spectrum of viewpoints on the issues related to radiological criteria for site cleanup and decommissioning. The NRC also held public meetings on the scope of the Generic Environmental Impact Statement (GEIS) during July 1993. The GEIS meetings were ...

1994-01-01

311

Spatially separated atomic layer deposition of Al2O3, a new option for high-throughput Si solar cell passivation  

British Library Electronic Table of Contents (United Kingdom)

Abstract A next generation material for surface passivation of crystalline Si is Al2O3. It has been shown that both thermal and plasma-assisted (PA) atomic layer deposition (ALD) Al2O3 provide an adequate level of surface passivation for both p- and n-type Si substrates. However, conventional time-resolved ALD is limited by its low deposition rate. Therefore, an experimental high-deposition-rate prototype ALD reactor based on the spatially separated ALD principle has been developed and Al2O3 deposition rates up to 1.2-nm/s have been demonstrated. In this work, the passivation quality and uniformity of the experimental spatially separated ALD Al2O3 films are evaluated and compared to conventional temporal ALD Al2O3, by use of quasi-steady-state photo-conductance (QSSPC) and carrier density ...

2011-01-01

312

Soil water retention at varying matric potentials following repeated wetting with modestly saline-sodic water and subsequent air drying  

Energy Technology Data Exchange (ETDEWEB)

Coal bed natural gas (CBNG) development in the Powder River (PR) Basin produces modestly saline, highly sodic wastewater. This study assessed impacts of wetting four textural groups (0-11%, 12-22%, 23 -33%, and > 33% clay (g clay/100 g soil) x 100%))with simulated PR or CBNG water on water retention. Soils received the following treatments with each water quality: a single wetting event, five wetting and drying events, or five wetting and drying events followed by leaching with salt-free water. Treated samples were then resaturated with the final treatment water and equilibrated to -10, -33, -100, -500, or -1,500 kPa. At all potentials, soil water retention increased significantly with increasing clay content. Drought-prone soils lost water-holding capacity between saturation and field capacity with repeated wetting and drying, whereas finer textured soils withstood this treatment better and had increased water-retention capacity at lower matric potentials.

2007-07-01

313

Results of surface activity and radiation field measurements made during surface decontamination experiments conducted at TMI-2  

International Nuclear Information System (INIS)

The Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI-2 Reactor Building during February and March 1982 and was designed to investigate the effectiveness of various surface decontamination techniques. The polar crane, D-rings, missile shields, refueling canal, fueling bridge, major equipment, floors and some walls were flushed with low pressure water. Water lances were directed manually and applied water at temperatures between ambient and 60"0C at a flow rate of about 95 liters per minute. In addition, floor surfaces on the 305-ft elevation and floor surfaces and major equipment on the 347-ft elevation were sprayed with high pressure water (floors in the Reactor Building are designated by their elevations above sea level). The water pressure in this case varied between 13.8 and 41.4 mPa and water temperature was at a maximum 60"0C. Certain surfaces were also decontaminated using either strippable coatings or a mechanical ...

1984-07-15

314

Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation  

International Nuclear Information System (INIS)

Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).

2005-07-15

315

Performance and emissions of a supercharged dual-fuel engine fueled by hydrogen-rich coke oven gas  

Energy Technology Data Exchange (ETDEWEB)

This study investigated the engine performance and emissions of a supercharged dual-fuel engine fueled by hydrogen-rich coke oven gas and ignited by a pilot amount of diesel fuel. The engine was tested for use as a cogeneration engine, so power output while maintaining a reasonable thermal efficiency was important. Experiments were carried out at a constant pilot injection pressure and pilot quantity for different fuel-air equivalence ratios and at various injection timings without and with exhaust gas recirculation (EGR). The experimental strategy was to optimize the injection timing to maximize engine power at different fuel-air equivalence ratios without knocking and within the limit of the maximum cylinder pressure. The engine was tested first without EGR condition up to the maximum possible fuel-air equivalence ratio of 0.65. A maximum indicated mean effective pressure (IMEP) of 1425 kPa and a thermal efficiency of 39% were obtained. However, the nitrogen ...

2009-12-15

316

On the stability of Innovar, a neuroleptic analgesic, for cardiovascular experiments.  

Science.gov (United States)

The effects of 0.2 and 0.5 mL/kg Innovar (a neuroleptic analgesic) on cardiovascular functions and reflexes in rabbits were measured. We recorded the effects of Innovar on arterial pressure, heart rate, respiration rate, ventricular contractility, arterial oxygen tension, as well as the drug's effects on the bradycardia and vasoconstrictor response to cigarette smoke stimulation of the nose (the so-called "nasopharyngeal reflex"). In animals given 0.2 mL/kg Innovar, all steady state cardiovascular variables had returned to pre-Innovar levels in 45 min, as had the efficacy of the nasopharyngeal reflex. In animals given 0.5 mL/kg Innovar, all steady state cardiovascular variables, except PaO2, were slightly but significantly depressed for up to 135 min after injection. The nasopharyngeal reflex returned to normal within 90 min. Because of the calmative and analgesic effects of Innovar, and its only moderate effects on cardiovascular functions and reflexes, we feel it ...

1981-11-01

317

Novel reduced pressure-balance syringe for chromatographic analysis.  

Science.gov (United States)

When withdrawing a fluid sample (for additional chromatographic analyses) from an apparatus operated at a reduced pressure, a typical syringe proves to be ineffective (even if it is equipped with a gas tight plunger). It simply does not create enough pressure differential to remove a fluid sample from a reduced pressure environment. We encountered such a situation as part of efforts to extend the operation of the advanced distillation curve protocol to reduced pressures. The problem was solved by the development of a pressure balance syringe that allows reliable and precise sampling from an apparatus operating at sub-ambient pressures. This new device uses an external vacuum source to evacuate a syringe barrel, allowing a user to withdraw fluid samples from environments with pressures as low as 0.5kPa. To demonstrate the operation of the newly developed device, distillate analyses were performed on two fluids at low pressure: a predefined validation mixture, and a ...

2010-09-19

318

Mound Facility activities in chemical and physical research: July--December 1977. [Kr-Xe and Kr-Ar diffusion; Ne-Ar thermal diffusion  

Science.gov (United States)

Isotope separation of Ar, C, /sup 3/He, Kr, Ne, O, and Xe isotopes is reported. TiFeH/sub x/, TiCoH/sub x/, TiCuH/sub x/, and VH/sub x/ were studied using NMR (proton relaxation times). VD/sub x/ and VT/sub x/ were synthesized. The problem of calculating the valence state of Pu is discussed. A series solution to the plutonium (N,H) characteristic equation is suggested. Shipments of /sup 231/Pa, /sup 230/Th, and /sup 229/Th are reported. Separation and processing of /sup 234/U are also reported. Theoretical methods were developed to calculate temperature distributions as functions of water flow rate in liquid thermal diffusion columns. Diffusion coefficients were measured from 300 to 1200/sup 0/K for Kr-Xe and Kr-Ar. New thermal diffusion factors are submitted for Ne-Ar.

1978-05-01

319

Morphology and thermal properties of electrospun fatty acids/polyethylene terephthalate composite fibers as novel form-stable phase change materials  

Energy Technology Data Exchange (ETDEWEB)

The ultrafine fibers based on the composites of polyethylene terephthalate (PET) and a series of fatty acids, lauric acid (LA), myristic acid (MA), palmitic acid (PA), and stearic acid (SA), were prepared successfully via electrospinning as form-stable phase change materials (PCMs). The morphology and thermal properties of the composite fibers were studied by field emission scanning electron microscopy (FE-SEM) and differential scanning calorimetry (DSC), respectively. It was found that the average fiber diameter increased generally with the content of fatty acid (LA) in the LA/PET composite fibers. The fibers with the low mass ratio maintained cylindrical shape with smooth surface while the quality became worse when the mass ratio is too high (more than 100/100). Moreover, the latent heat of the composite fibers increased with the increase of LA content and the phase transition temperature of the fibers have no obvious variations compared with LA. In contrast, ...

2008-11-15

320

Modelling of temperature field in a reactor vessel downcomer during transients  

International Nuclear Information System (INIS)

The B test series from the course of ISP Nr. 43 was analysed. The boundary conditions measured include the initial temperature of the primary system, the front/slug injection flowrate and temperature, and the pressure drop across the core. Temperature data were collected at 185 thermocouple positions in the downcomer and 38 positions in the lower plenum. The frequency of data acquisition for code predictions was set to 2 Hz, which corresponds to the acquisition frequency of the two experimental setups. Calculations were performed using the FLUENT Computational Fluid Dynamics (CFD) code. This program is based on the finite volume method, The computational mesh was generated by the pre-processor - GAMBIT program. FLUENT uses a control-volume-based technique to convert the governing equations to algebraic equations, which can be solved numerically. This control volume technique consists of integrating the governing equations about each control volume, yielding discrete equations that ...

2003-08-17

321

Micro and nano patterning by focused ion beam enhanced adhesion  

International Nuclear Information System (INIS)

We report a new method of generating nano and micro patterns using focused ion beam (FIB) induced adhesion. The method utilizes selective irradiation of thin metallic films grown on substrates by focused ion beam followed by peel off. After peel off of the irradiated thin film it is observed that the ion beam scanned portions are retained on the substrate, creating nano and micro patterns. The method is suitable for materials of which the adhesion to the substrate can be improved by ion bombardment. The phenomenon has been demonstrated by creating gold nano patterns of different shapes and sizes ranging from 500 nm to 5 #mu#m on SiO_2-Si substrate using 10-30 keV Ga FIB at beam currents up to 10 pA. The mechanism involved in the process has been discussed. The technique could be utilized to prepare micro and nano patterns of thin films deposited on an appropriate substrate for optical, plasmonic and sensor related applications.

2009-05-01

322

Mercury balance analysis; Massestroemsanalyse for kviksoelv  

Energy Technology Data Exchange (ETDEWEB)

A detailed assessment of the consumption of mercury, divided into use areas, was carried out. Disposal and emissions to the environment were also qualified. The assessment is mainly based on data from 1992 - 1993. The most important source of emission of mercury to air is solid waste incineration which is assessed in particular to be due to the supply of mercury in batteries (most likely mercury oxide batteries from photo equipment) and to dental fillings. The second most important source of mercury emission to air is coal-fired power plants which are estimated to account for 200-500 kg of mercury emission p.a. Other mercury emissions are mainly related to waste treatment and disposal. The consumption of mercury is generally decreasing. During the period from 1982/83 - 1992-93, the total consumption of mercury in Denmark was about halved. This development is related to the fact that consumption with regard to several important use areas (batteries, dental fillings, ...

1996-08-01

323

Magnetism in "3He  

International Nuclear Information System (INIS)

The nuclear magnetic susceptibility, #chi#, of "3He is seen to nearly obey a pure Curie Law, #chi# = C/T, over the temperature range 0.5 mK < T < 2 K when contained in the 20#ALPHA#, multiply connected pores of Vycor glass at low external pressure. Raising the external pressure to 5 bar (1 bar 100 kPa) causes the susceptibility to obey the Curie-Weiss law, #chi# = C' /T - #THETA# whose #THETA# = 0.3 mK. The longitudinal relaxation time, T_1, varies monotonically with T between 17 and 90 ms at both pressures. At 5 bar, the transverse relaxation time T_2*, is nearly temperature independent (about 600 #mu#s) above 2 mK. Below 2 mK, T_2* drops precipitously. Preliminary measurements indicate that the magnetism is produced by atoms that can flow through the pores of the Vycor glass. (10 refs., fig.).

1986-10-01

324

Level structure of "2"1"6At  

International Nuclear Information System (INIS)

The level structure and configurations of "2"1"6At have been studied by observing the alpha decay of "2"2"0Fr, which is in secular equilibrium with "2"2"4Ac. Six of the 16 observed states are tentatively assigned to the configuration #pi#(h_9_/_2)"3#upsilon#(g_9_/_2)"5, and four to the mixed configuration #pi#(h_9_/_2)"3#upsilon#(g_9_/_2)"4(i_1_1_/_2)+#pi#(h_9_/_2)"2(f _7_/_2)#upsilon#(g_9_/_2)"5. These two configurations in "2"1"6At are compared with the corresponding configurations in "2"1"2Bi and "2"1"0Bi. The shape transitions are traced from the quadrupole-octupole deformed "2"2"4Ac through "2"2"0Fr and "2"1"6At, to "2"1"2Bi, described by the spherical shell model, using the alpha decay sequence beginning with "2"2"8Pa. copyright 1996 The American Physical Society.

325

Laboratory differential simulation design method of pressure absorbers for carbonization of phenolate solution by carbon dioxide in coal-tar processing  

Energy Technology Data Exchange (ETDEWEB)

A laboratory differential simulation method is used for the design of carbonization columns at coal-tar processing in which phenols are regenerated from phenolate solution by carbon dioxide absorption. The design method is based on integration of local absorption rates of carbon dioxide along the column. The local absorption rates into industrial phenolate mixture are measured in a laboratory model contactor for various compositions of the gas and liquid phases under the conditions that ensure the absorption rates in the laboratory absorber simulate the local rates in the industrial column. On the bases of the calculations, two-step carbonization columns were designed for 30000 t/year of the phenolate solution treatment by carbon dioxide. The absorption proceeds at higher pressure of 500 kPa and temperatures from 50 to 65 C, pure carbon dioxide is used and toluene is added. These conditions have the following favourable effects: (I) significant size reduction of ...

2009-01-15

326

Influence of bias voltage on the formation and properties of iron-based nitrides produced by plasma nitriding  

Energy Technology Data Exchange (ETDEWEB)

A series of experiments have been conducted on AISI 5140 low alloy steel using a hollow cathode discharge-assisted plasma nitriding apparatus with the aim of elucidating the role of substrate bias voltages in plasma nitriding process. For comparison, some samples were nitrided with applied substrate bias (-50 V) while other samples were nitrided at floating potential. Treatments were carried out in NH{sub 3} atmosphere of 150 Pa at temperatures ranging from 450 {sup o}C to 550 {sup o}C for 2 h, 4 h, and 6 h. The nitrided samples were characterized by optical microscopy, X-ray diffraction and micro-hardness measurement. The corrosion behaviors were evaluated using anodic polarization tests in 3.5% NaCl solution. The results showed that the microstructure and phase constituents of the nitride layers were strongly influenced by the bias voltages. It was also demonstrated that the better corrosion resistance with a thicker nitrided layer was obtained on the biased ...

2010-05-14

327

Influence of bias voltage on the formation and properties of iron-based nitrides produced by plasma nitriding  

International Nuclear Information System (INIS)

A series of experiments have been conducted on AISI 5140 low alloy steel using a hollow cathode discharge-assisted plasma nitriding apparatus with the aim of elucidating the role of substrate bias voltages in plasma nitriding process. For comparison, some samples were nitrided with applied substrate bias (-50 V) while other samples were nitrided at floating potential. Treatments were carried out in NH_3 atmosphere of 150 Pa at temperatures ranging from 450 "oC to 550 "oC for 2 h, 4 h, and 6 h. The nitrided samples were characterized by optical microscopy, X-ray diffraction and micro-hardness measurement. The corrosion behaviors were evaluated using anodic polarization tests in 3.5% NaCl solution. The results showed that the microstructure and phase constituents of the nitride layers were strongly influenced by the bias voltages. It was also demonstrated that the better corrosion resistance with a thicker nitrided layer was obtained on the biased sample.

2010-05-14

328

In-situ and post-irradiation fatigue properties of the ferritic-martensitic steel Manet at T=250 C  

Energy Technology Data Exchange (ETDEWEB)

Strain controlled fatigue experiments on the modified ferritic-martensitic 12% Cr-steel Manet have been performed during, after and without irradiation. Continuous push-pull cycling of the hollow fatigue specimens with a cycle ratio R=-1, an axial strain rate of 8.10{sup -4} s{sup -1} and total strain ranges {Delta}{epsilon}{sub t} between 0.42% and 1.0% has been applied in vacuum (5.10{sup -3} Pa) at T=250 C. For the irradiation, a 104 MeV {alpha}-particle beam was used. Compared to unirradiated specimens, in-beam specimens undergo irradiation hardening at an advanced fatigue/implantation stage. Post-irradiation specimens show significantly higher total stress amplitudes and reduced fatigue lives. TEM investigations of in-beam and post-irradiation specimens reveal helium bubbles with different diameters on internal surfaces and in the matrix. (orig.).

1996-10-01

329

Improved adhesion for thermoplastic polymers using oxyfluorination  

Energy Technology Data Exchange (ETDEWEB)

Industrial applications of thermoplastic polymers are often limited by their poor adhesion properties. In this work the effect of surface oxyfluorination on the adhesion properties was investigated for polyethylene (PE), polyoxymethylene (POM), polybutylene terephthalate (PBT) and polyamide 6 (PA6). The adhesive joint strength was quantified using lap-shear tests. These results were correlated with the changes in the chemical composition of the surface, determined by X-ray photoelectron spectroscopy (XPS), in the surface free energy, measured by the contact angle method, and in the topography, using white-light confocal microscopy. The adhesive strength is strongly improved for all four polymers, but the degree of this increase depends on the polymer type. The surface free energy shows a similar trend for all four polymers. A high surface free energy exceeding 50 mN/m was observed after oxy-fluorination, whereby the polar component was strongly predominant. Surface ...

2008-03-15

330

IECEC '87; Proceedings of the Twenty-second Intersociety Energy Conversion Engineering Conference, Philadelphia, PA, Aug. 10-14, 1987. Volumes 1, 2, 3, and 4  

International Nuclear Information System (INIS)

Papers are presented on space power requirements and issues, space photovoltaic systems, space solar dynamic systems, space thermal systems, manned and unmanned space power systems, thermionics, and thermoelectrics. Also considered are high power devices for space power systems, high power conversion for space power systems, 1-10 kWe nuclear space power sources, 100-kW class nuclear power concepts, space reactor safety, and multimegawatt space nuclear power systems. Other topics include space power systems automation, space kilovolt technology, space power electronics, space lithium and nickel-cadmium batteries, lithium sodium storage, and space fuel cells. Papers are also presented on space nickel hydrogen batteries, alternative energy concepts and fuels, fuel cell technology, flow batteries, high-temperature batteries, energy conservation, battery energy storage, thermal energy storage, heat engines, MHD power systems, nuclear fission, and the Stirling cycle.

1987-08-10

331

Hydrogen transport behavior of Timetal-21S alloy  

International Nuclear Information System (INIS)

Ti-15Mo-2.7Nb-3Al-0.2Si (Timetal-21S), a metastable #beta#-titanium alloy, is a candidate material for titanium matrix composite structures in hydrogen-fueled hypersonic planes because of its excellent formability and adequate mechanical properties in the 500--800 C temperature range. The alloy is strengthened through the precipitation of fine #alpha# particles in the #beta# matrix. The mechanical properties and microstructures are controlled by a solutionizing/aging heat treatment. A major concern in using titanium alloys in hydrogen service is the embrittlement caused by the precipitation of hydrides. It is believed that the large solubility of hydrogen in the #beta#-phase would preclude the precipitation of hydrides in Beta titanium alloys, especially at low hydrogen pressures. However, depending on the hydrogen content, a shift in the ductile/brittle transition temperatures to levels much higher than room temperature has been reported for Timetal-21S alloy. The objective of the ...

332

High temperature strengthening mechanism of hafnium carbide in a tungsten-rhenium matrix  

Energy Technology Data Exchange (ETDEWEB)

The interrelationship between the testing temperature and HfC strength increment of an arc-melted W-3.6Re-0.4HfC was determined from 1950 K to 2980 K in a vacuum of better than 1.3{times}10{sup {minus}5} Pa (10{sup {minus}7} torr). The present research was focused on the characteristic temperature at which the rapid coarsening of HfC particles occurred and the effect of the second-phase particle size on the high temperature strength properties of this material. It was found that the HfC particle strengthening was effective in a W-Re matrix up to a characteristic temperature of 2450 K in the short-term tensile test. Carbon was found to be the rate-limiting solute in the HfC particle growth. The strength of HfC strengthened alloy at temperature above 0.5 T{sub m} is proportional to the square root of particle volume fraction. The yield strengths of W-3.6Re-0.26HfC calculated based on the particle statistical distribution had good agreement with the experimental ...

1991-01-01

333

High temperature strengthening mechanism of hafnium carbide in a tungsten-rhenium matrix  

International Nuclear Information System (INIS)

The interrelationship between the testing temperature and HfC strength increment of an arc-melted W-3.6Re-0.4HfC was determined from 1950 K to 2980 K in a vacuum of better than 1.3x10"-"5 Pa (10"-"7 torr). The present research was focused on the characteristic temperature at which the rapid coarsening of HfC particles occurred and the effect of the second-phase particle size on the high temperature strength properties of this material. It was found that the HfC particle strengthening was effective in a W-Re matrix up to a characteristic temperature of 2450 K in the short-term tensile test. Carbon was found to be the rate-limiting solute in the HfC particle growth. The strength of HfC strengthened alloy at temperature above 0.5 T_m is proportional to the square root of particle volume fraction. The yield strengths of W-3.6Re-0.26HfC calculated based on the particle statistical distribution had good agreement with the experimental values from 1950 K to 2980 K. ...

1991-01-06

334

Glass-ceramic sealants for solid oxide fuel cells: Part I. Physical properties  

International Nuclear Information System (INIS)

A family of sealant materials has been developed for use in the solid oxide fuel cell (SOFC) and in other applications in the temperature range of 800 endash 1000 degree C. These materials are based on glasses and glass-ceramics in the SrO endash La_2O_3 endash Al_2O_3 endash B_2O_3 endash SiO_2 system. The coefficients of thermal expansion (CTE) for these materials are in the range of 8 endash 13x10"-"6/degree C, a good match with those of the SOFC components. These sealant materials bond well with the ceramics of the SOFC and, more importantly, form bonds that can be thermally cycled without failure. At the fuel cell operating temperature, the sealants have viscosities in the range of 10"4-10"6 Pa-s, which allow them to tolerate a CTE mismatch of about 20% among the bonded substrates. The gas tightness of a sample seal was demonstrated in a simple zirconia-based oxygen concentration cell. copyright 1996 Materials Research Society.

335

Evaluation of an eastern shale oil residue as an asphalt additive  

Energy Technology Data Exchange (ETDEWEB)

An evaluation of eastern shale oil (ESO) residue as an asphalt additive to reduce oxidative age-hardening and moisture susceptibility was conducted. The ESO residue, having a viscosity of 23.9 Pa{sm_bullet}s at 60{degrees}C (140{degrees}F), was blended with three different petroleum-derived asphalts, AAD-1, AAK-1, and AAM-1, that are known to be very susceptible to oxidative aging. Rheological and infrared analyses of the unaged and aged asphalts and the blends were then conducted to evaluate oxidative age-hardening. In addition, the petroleum-derived asphalts and the blends were coated onto three different aggregates, Lithonia granite (RA), a low-absorption limestone (RD), and a silicious Gulf Coast gravel (RL), and compacted into briquets. Successive freeze-thaw cycling was then conducted to evaluate the moisture susceptibility of the prepared briquets. The abbreviations used above for the asphalts and the aggregates are part of the Strategic Highway Research ...

1995-12-19

336

Enhanced MALDI-TOF MS Analysis of Phosphopeptides Using an Optimized DHAP/DAHC Matrix  

Science.gov (United States)

Selecting an appropriate matrix solution is one of the most effective means of increasing the ionization efficiency of phosphopeptides in matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In this study, we systematically assessed matrix combinations of 2, 6-dihydroxyacetophenone (DHAP) and diammonium hydrogen citrate (DAHC), and demonstrated that the low ratio DHAP/DAHC matrix was more effective in enhancing the ionization of phosphopeptides. Low femtomole level of phosphopeptides from the tryptic digests of ?-casein and ?-casein was readily detected by MALDI-TOF-MS in both positive and negative ion mode without desalination or phosphopeptide enrichment. Compared with the DHB/PA matrix, the optimized DHAP/DAHC matrix yielded superior sample homogeneity and higher phosphopeptide measurement sensitivity, particularly when multiple phosphorylated peptides were assessed. Finally, the DHAP/DAHC matrix was applied to identify ...

2010-01-01

337

Effects of atmospheric pressure on tracking failure of organic insulating materials; Yuki zetsuen zairyo no tai tracking sei ni oyobosu kiatsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated Polyester Resins (UP) has no significant dependence on lower ...

1995-11-20

338

Does DaYa-Bay Reactor Play an Important Role in Theta_{13} of Lepton Mixing (PMNS) Matrix ?  

CERN Document Server

Reactor neutrinos play an important role in determining parameter theta_{13} in the lepton mixing (PMNS) matrix. Next important step on measuring PMNS matrix could be to build another reactor neutrino experiment in DaYa bay, China, to search the possible oscillations via sin^2 (2theta_{13}) and Delta m^2_{13}. We consider 4 different schemes for positions of three 8-ton detectors of this experiment, and simulate the results with respect to an array of assumed ''true'' values of physics parameters. Using three kinds of analysis method, we suggest a best scheme for DaYa-Bay which is to place a detector 2200m ~ 2500m symmetrically away from two reactors, and to put the other two detectors closer to their corresponding reactors respectively, almost at a 100m \\~ 200m distance. Moreover, with conservative assumption on the experimental technique, we construct series of allowed regions from our simulation results, and give detailed explanations therein. The movable detectors in DaYa-Bay can ...

2004-01-01

339

Design of the ZTH vacuum liner  

Energy Technology Data Exchange (ETDEWEB)

The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between pairs of the 16 diagnostic stations to complete the torus. The ...

1987-01-01

340

Consistency Improvement of some steel types by plasma nitriding  

International Nuclear Information System (INIS)

Plasma nitriding is a powerful technique for modifying the phase-structure of the material surface layers, which affect the mechanical, physical and chemical properties of material. The effect of plasma nitriding on the surface properties of three types of steel (low carbon, AISI-304 and H13 (hardened)) has been investigated. The steel samples were plasma nitrided in vacuum of 10"-"1Pa with gas mixture of (N_2, H_2) at 530 Centigrade degree for a duration of 14 hours. Vickers microhardness measurements and XRD phase analysis of the treated and untreated samples were carried out. The diffraction patterns of treated steels revealed that new phases of #gamma#-Fe_4N, #epsilon#-Fe_3N and (Fe,Cr)_2N were formed. The maximum treated depths were about 5, 6 and 45 #mu#m for low carbon, AISI-304 and H13 (hardened) nitrided steel respectively. The microhardness was increased by about 150%, 200% and 140% for low carbon, AISI-304 and H13 nitrided samples respectively. This ...

2004-12-04

341

Changes in Sea-Level Pressure over South Korea Associated with High-Speed Solar Wind Events  

CERN Document Server

We explore a possibility that the daily sea-level pressure (SLP) over South Korea responds to the high-speed solar wind event. This is of interest in two aspects: First, if there is a statistical association this can be another piece of evidence showing that various meteorological observables indeed respond to variations in the interplanetary environment. Second, this can be a very crucial observational constraint since most models proposed so far are expected to preferentially work in higher latitude regions than the low latitude region studied here. We have examined daily solar wind speed ${\\rm V}$, daily SLP difference ${\\rm \\Delta SLP}$, and daily ${\\rm \\log(BV^{2})}$ using the superposed epoch analysis in which the key date is set such that the daily solar wind speed exceeds 800 ${\\rm kms^{-1}}$. We find that the daily ${\\rm \\Delta SLP}$ averaged out of 12 events reaches its peak at day +1 and gradually decreases back to its normal level. The amount of positive deviation ...

2011-01-01

342

CO oxidation over Pt/. gamma. -Al sub 2 O sub 3 under high pressure  

Energy Technology Data Exchange (ETDEWEB)

The oxidation of CO over a Pt/{gamma}-Al{sub 2}O{sub 3} catalyst was studied by cyclic injection of CO and O{sub 2} pulses under CO and O{sub 2} pressures of 2 and 1 kPa, respectively, at temperatures of 330-650 K. A boundary reaction model yielded kinetic parameters in agreement with the results of published low-pressure studies. For CO{sub 2} formation from O{sub 2}(g) + (CO){sub ad}, CO desorption was the most important step and showed multipeak characteristics and a low activation energy (10 kJ/mol) for the boundary reaction was found. CO{sub 2} formation from O{sub 2}(g) + (CO) as well as from CO(g) + (O){sub ad} resulted from boundary reaction at oxygen island. A reaction mechanism was proposed to account for kinetics observed and interpret the varying observations noted in low-pressure studies in terms of diffusion-disguised kinetics.

1989-07-01

343

Assessment of asymptomatic liver fibrosis in alcoholic patients using fibroscan: prospective comparison with seven non-invasive laboratory tests  

British Library Electronic Table of Contents (United Kingdom)

Summary Background Systematic screening for liver fibrosis in heavy-drinking patients is a challenge. Aims To assess Fibroscan for non-invasive diagnosis of asymptomatic liver fibrosis in alcohol abuse patients, to determine diagnostic liver stiffness cut-off values and to compare performance of Fibroscan with seven non-invasive laboratory tests. Methods One hundred and three alcoholic patients were studied. Liver fibrosis was staged by METAVIR system. Fibroscan, Fibrotest, Fibrometer, Hepascore, APRI, PGA, PGAA and hyaluronic acid tests were performed. Liver stiffness cut-offs were determined using receiver-operating characteristic (ROC) curves. Results Liver stiffness was correlated with fibrosis (r = 0.72, P < 0.014), with median at 5.7, 6.3, 8.4, 15 and 47.3 kPa for F0 (n = 8), F1 (n =...

2008-01-01

344

Application of radionuclide X-ray fluorescence analysis to the monitoring of the quality of air  

International Nuclear Information System (INIS)

An X-ray fluorometric train was set up for analyzing gravitational fallout, and tested on standard reference samples of fly ashes from conventional power plants. Analysis of thin layers proved inappropriate, and therefore pelletization of the samples, either alone or together with the X-ray MIX binder, was applied. Sample grinding in an agate mortar was found sufficient to suppress the particle size effect. The optimum pressure was 20 MPa. The optimum geometry was sought for "1"0"9Cd source, and limits of detection of 2.78-0.47 #mu#g were achieved for Cr-Zr elements. Tominaga's method was employed for matrix effect correction. Ti, Fe, Cu, Zn, As, Rb, Sr, Zr and Pb were determined in the SRM's; the relative errors ranged from units per cent (for Zn, Rb, Sr and Zr present in concentrations about 100 ppm and for Fe in concentrations of units per cent) up to 45% (for Ti present in a concentration of 0.67%). The method developed was applied to the investigation of fallout in the town of ...

1990-10-01

345

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g (PaCO{sub 2}=46.3 mmHg). ...

1998-02-01

346

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray fluorescence analysis but also ash in coal by the method of ...

1987-05-13

347

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of the American Collage ...

2002-03-01

348

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis; Determination of optimum conditions of image processing  

Energy Technology Data Exchange (ETDEWEB)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same accuracy as the ...

1993-06-01

349

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis  

International Nuclear Information System (INIS)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same accuracy as the ...

1993-01-01

350

The Use of Particulate Bone Grafts From the Mandible for Maxillary Sinus Floor Augmentation Before Placement of Surface-Modified Implants: Results From Bone Grafting to Delivery of the Final Fixed Prosthesis  

British Library Electronic Table of Contents (United Kingdom)

PurposeThis prospective study followed 61 patients who were partially dentulous and considered to have insufficient bone volume for routine implant treatment and consequently underwent sinus inlay bone grafting.Patients and MethodsThe patients were treated with maxillary sinus floor augmentation with particulated autogenous bone from the mandibular ramus/corpus. After a healing period, dental implants (n = 180) were installed.ResultsRadiographic examination revealed average residual vertical bone heights of 6.5 mm in the first premolar region, 3.8 mm in the second premolar region, 3.5 mm in the first molar region, and 2.6 mm in the second molar region. The average implant lengths were 12 mm in the first premolar region and 11 mm in the second premolar, first, and second molar regions. All ...

2008-01-01

351

System suitable for use in neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate thermal neutrons from the pulses and ...

1990-02-07

352

System suitable for use in neutron radiography  

International Nuclear Information System (INIS)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate thermal neutrons from the pulses and ...

1988-07-20

353

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. ...

2001-04-01

354

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. Further, optimal ...

2001-04-01

355

Soft tissue signal abnormality associated with eosinophilic granuloma. Correlation of MR imaging with pathologic findings  

Energy Technology Data Exchange (ETDEWEB)

Six patients with eosinophilic granuloma were studied retrospectively in order to correlate the MRI appearances with the pathology. Ages ranged from 2 years 6 months to 11 years. The bones involved were the humerus, ulna, radius, femur, clavicle and ilium. Plain films, MRI and pathology specimens were obtained. A lytic lesion with indistinct margins, endosteal erosions and periosteal reaction was seen in all cases on plain radiographs. Bone marrow signal was decreased on T1-weighted images and increased on T2-weighted images throughout the bony lesion in all cases. T2-weighted images showed extensive soft-tissue abnormalities suggesting inflammatory changes in four cases. In two cases abnormalities were limited. Extensive changes correlated histologically with an early phase lesion. Localized minor changes were associated with a mid-phase lesion. Inflammatory soft-tissue changes could be associated with eosinophilic granuloma. The size of the soft tissue mass ...

1994-09-01

356

Soft tissue manifestations of early rheumatic disease. Imaging with MRI  

International Nuclear Information System (INIS)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a particular rheumatic disease (PsA; r=0.934; ...

2006-08-01

357

Root canal preparation with the NiTi systems K3, Mtwo and ProTaper  

British Library Electronic Table of Contents (United Kingdom)

Abstract The aim of this paper was to examine the result of rotary root canal preparation with the nickel-titanium (NiTi) systems K3, ProTaper and Mtwo. One hundred and fifty curved artificial root canals and 60 mesial canals of human mandibular molars were selected. In the group of curved artificial canals, all canals were prepared to size 35/0.04 taper with the three systems. In the group of human mandibular molars, the teeth with mature root canals were radiographed with silver points inserted in bucco-lingual and in mesio-distal positions. In the artificial root group, one K3 instrument separated. Mtwo (20%) showed significantly (P = 0.003) less zips than K3 (46.9%) or ProTaper (50%). There were no significant differences in ledge and elbow formation. K3 and Mtwo had the lowest percent...

2007-01-01

358

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron beam and the ...

1988-09-01

359

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron beam and the electronic components. This paper describes the methods and ...

1988-01-01

360

Radionuclide liver and bone scanning in the evaluation of patients with endometrial carcinoma  

International Nuclear Information System (INIS)

Staging bone scans or skeletal surveys were obtained of 97 patients with endometrial carcinoma. Of the 77 patients with Stage I or II disease, no metastases were identified at staging. Three patients in the entire series demonstrated bony metastases; all of these metastases were detectable by radionuclide bone scan and radiographic bone survey. Eighty-nine patients were examined with radionuclide liver/spleen scanning at the time of staging. Four of the 89 initial scans were interpreted as demonstrating hepatocellular disease, and all four patients had abnormal liver function studies. Only one patient demonstrated a possible hepatic metastasis at initial diagnosis. This patient also had abnormal liver function studies. Based on these results, bone surveys and radionuclide bone scans are not indicated as screening procedures in endometrial carcinoma. It is suggested that screening for liver metastases in patients with endometrial carcinoma is not warranted in ...

361

Radiographic in-situ measurements of intrinsic stresses between 750 C and 900 C. Optimisation of the measuring system; Roentgenographische In-situ-Messungen der Eigenspannungen zwischen 750 C und 900 C. Optimierung der Messeinrichtung  

Energy Technology Data Exchange (ETDEWEB)

One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be increased by more than a factor of 4. The use of nitrogen as protective gas instead ...

2007-07-01

362

Quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and follow-up of renal osteodystrophy in dialysis ...

363

Prognostic precision in postoperative /sup 99m/Tc-MDP scintimetry after femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

A 2-year follow-up regarding healing complications, such as redisplacement, nonunion, and segmental collapse of the femoral head, was performed in 306 patients operated on for femoral neck fracture and examined with /sup 99m/Technetium-MDP scintimetry within 2 weeks postoperatively. Scintimetric evaluation was performed by selecting regions of interest over the femoral head on the fracture side and the intact side and by comparing the uptake. A femoral head ratio fractured/intact side thus was obtained. Of 199 patients with an intact femoral head uptake (ratio less than or equal to 1.0), 181 showed no signs of healing complications at 2 years, whereas 18 had developed healing complications. Of 107 cases with a deficient femoral-head uptake (ratio < 1.0), 96 had developed healing complications within 2 years from the operation, while 11 cases had no signs of radiographic complications. We conclude that /sup 99m/Tc-MDP scintimetry performed within 2 weeks from ...

1987-01-01

364

Prognostic precision in postoperative "9"9"mTc-MDP scintimetry after femoral neck fracture  

International Nuclear Information System (INIS)

A 2-year follow-up regarding healing complications, such as redisplacement, nonunion, and segmental collapse of the femoral head, was performed in 306 patients operated on for femoral neck fracture and examined with "9"9"mTechnetium-MDP scintimetry within 2 weeks postoperatively. Scintimetric evaluation was performed by selecting regions of interest over the femoral head on the fracture side and the intact side and by comparing the uptake. A femoral head ratio fractured/intact side thus was obtained. Of 199 patients with an intact femoral head uptake (ratio #<=# 1.0), 181 showed no signs of healing complications at 2 years, whereas 18 had developed healing complications. Of 107 cases with a deficient femoral-head uptake (ratio < 1.0), 96 had developed healing complications within 2 years from the operation, while 11 cases had no signs of radiographic complications. We conclude that "9"9"mTc-MDP scintimetry performed within 2 weeks from femoral neck fracture ...

365

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, radiation output and beam ...

366

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ultra-high resolution ...

2001-01-01

367

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past and present ...

368

Neutron radiography with the cyclotron, 4  

International Nuclear Information System (INIS)

A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual application to dynamical fluid motion of real-time neutron ...

1986-01-01

369

Low field magnetic resonance imaging of femoral neck fractures  

International Nuclear Information System (INIS)

Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).

370

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium scanning has been ...

1998-06-01

371

Femoral head viability following hip fracture. Prognostic role of radionuclide bone imaging  

Energy Technology Data Exchange (ETDEWEB)

A retrospective study was made of all radionuclide (RN) bone images performed at our institution over a two-year period to evaluate femoral head viability after nonpathologic fracture of the femoral neck. Twelve patients had avascular femoral heads during the perioperative period, of which nine had adequate follow-up. Seven of these nine patients had follow-up bone images. Revascularization occurred in four patients, while three had persistent absence of femoral head uptake. With clinical follow-up ranging from four to 29 months (median: 14 months), only two of these nine patients developed clinical or radiographic evidence of osteonecrosis. RN bone imaging performed in the perioperative period does not reliably predict the development of post-traumatic osteonecrosis of the femoral head and, at present, should not be used to determine prospectively method of treatment of femoral neck fracture.

1985-03-01

372

Femoral head viability following hip fracture. Prognostic role of radionuclide bone imaging  

International Nuclear Information System (INIS)

A retrospective study was made of all radionuclide (RN) bone images performed at our institution over a two-year period to evaluate femoral head viability after nonpathologic fracture of the femoral neck. Twelve patients had avascular femoral heads during the perioperative period, of which nine had adequate follow-up. Seven of these nine patients had follow-up bone images. Revascularization occurred in four patients, while three had persistent absence of femoral head uptake. With clinical follow-up ranging from four to 29 months (median: 14 months), only two of these nine patients developed clinical or radiographic evidence of osteonecrosis. RN bone imaging performed in the perioperative period does not reliably predict the development of post-traumatic osteonecrosis of the femoral head and, at present, should not be used to determine prospectively method of treatment of femoral neck fracture.

373

Ewing's sarcoma. Evaluation of radiotherapy and control of the primary tumor  

International Nuclear Information System (INIS)

From 1964 to 1973 at the Institute of Oncology and Radiobiology, Havana City, 18 clinical histories were studied, all of them from patients with Erwing's sarcoma, histologically diagnosticated by biopsy. Age, sex, race, traumatism background, hemogram disturbances, radiographic signs, primary tumor localization, and early treatment, were exposed. Early treatment in 14(83%) patients as radiotherapy. Local recurrence or metastasis was presented in 10(55,5%) patients during the two first years following attack treatment. Five (35,7%) patients was the survival rate within five years starting early treatemt. After five years, three (21,4%) patients were alive: for 18 and 14 year, and 64 month period; two patients died at 62 and 64 months. It is concluded that this survival may be increased by initial behaviour enclosed at the technologic therapeutic patterns of the the Institute of Oncology and Radiobiology, of Havana City. (author).

374

Effect of irradiation on bone remodelling and the structural integrity of the vertebral column. Doctoral thesis  

Energy Technology Data Exchange (ETDEWEB)

The effects of therapeutic levels of radiation on the axial properties of the primate vertebral column were studied. Seven male rhesus monkeys (Macaca mulatta) were irradiated with a single does of 1300 cGy to the specific lumbar vertebrae of L2, L3, and L4. Three additional animals served as controls. Radiographs were taken before the radiation treatment and just prior to sacrifice to determine density changes in the bone. The animal subjects were sacrificed 105 days following the radiation exposure. Biomechanical testing was completed on lumbar levels 2 and 3 to identify changes in strength characteristics following radiation treatment. Histomorphometric analysis of lumbar vertebrae level 4 was completed to identify volume and surface density changes as well as cellular changes. Tetracycline, dicarbomethylaminomethyl fluorescein (DCAF), and xylenol orange were used as bone labeling agents to aid in the histomorphometry and to obtain dynamic parameter changes.

1990-01-01

375

Do gender and torus mandibularis affect mandibular cortical index? A cross-sectional study  

Science.gov (United States)

BackgroundThe interactions between torus and several factors such as age, gender, and dental status have not been studied comprehensively. The purpose of this study was to determine the effect of gender on the mandibular cortical index (MCI) and to investigate a possible association between torus mandibularis (TM) and MCI.MethodsThe study consisted of 189 consecutive patients referred to Department of Oral Diagnosis and Radiology of Hacettepe University within 30 workdays. Patients who did not have systemic disorders affecting bone density were included; and the age, gender, dental status and existing TM of the patients were recorded. Morphology of the mandibular inferior cortex was determined according to Klemitti's classification on panoramic radiographs.ResultsMCI was affected by age and gender (P 0.05).ConclusionIn the study population, MCI was affected by age and gender. As age increased, semilunar defects could be seen on the cortex of the mandible and MCI ...

2007-10-30

376

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...

1984-09-01

377

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...

1984-01-01

378

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters  

International Nuclear Information System (INIS)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as microcalcifications. The introduction of the storage ...

379

Diagnostic capabilities of quantitative bone scintigraphy in ankylosing spondylitis: A comparison with radiography  

International Nuclear Information System (INIS)

In 576 patients quantitative scintigraphy of the sacroiliac joints and the spinal cord with "9"9"mTc-pyrophosphate was performed. 328 were patients with proven ankylosing spondylitis according to the New York criteria. 120 were patients with a clinically and roentgenologically suspected ankylosing spondylitis and 128 persons formed a healthy control group. The count rate in small regions of interest (ROI) in the sacroiliac joints, the spinal cord and the os sacrum were compared on the basis of indexes. The scintigraphic data of patients with ankylosing spondylitis were compared with the healthy control group and with the radiographic findings and radiologic staging of the disease. In a longitudinal follow-up study during 1 to 6 years these investigations were continued together with clinical and roentgenological checks. Quantitative bone scintigraphy provides characteristic indexes for ankylosing spondylitis, indicating the increased mineral metabolism of the ...

380

Determination of time-dependent void fraction distribution in bubbly two-phase flow by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more suitable fluid than light water for void fraction measurements in large-diameter flow systems.

1995-01-01

381

Dental caries in adolescents with attention deficit hyperactivity disorder: a population-based follow-up study  

British Library Electronic Table of Contents (United Kingdom)

Blomqvist M, Ahadi S, Fernell E, Ek U, Dahllf G. Dental caries in adolescents with attention deficit hyperactivity disorder: a population-based follow-up study. Eur J Oral Sci 2011; 119: 381-385. 2011 Eur J Oral Sci This study tested the hypothesis that adolescents with attention deficit hyperactivity disorder (ADHD) exhibit a higher prevalence of caries than adolescents in a control group. Thirty-two adolescents with ADHD and a control group of 55 adolescents from a population-based sample, all 17-yr of age, underwent a clinical and radiographic dental examination. The mean--SD number of decayed surfaces (DS) was 2.0--2.2 in adolescents with ADHD and 0.9--1.4 in adolescents of the control group. Thirty-one per cent of the adolescents in the ADHD group had no new caries lesions (DS-=-0) co...

2011-01-01

382

Demonstration of mobile accelerator neutron radiography for in situ detection of moisture and corrosion in aircraft structures  

Energy Technology Data Exchange (ETDEWEB)

A demonstration of the first mobile 'on-off' neutron radiography system, developed by Vought Corporation Advanced Technology Center, has been conducted at McClellan Air Force Base. On-site neutron radiography operations with the engineering model were carried out to demonstrate the potential of such a system for in situ detection of hidden moisture and corrosion in aircraft structures, and to assess the performance of the unique hardware system in a depot environment. Inspections were performed on F-111 and F-106 aircraft, and several structures removed from T-39 and A-10 aircraft were also inspected. The effectiveness of the new N-ray system for imaging moisture and corrosion was confirmed after subsequent removal of skins from some of the F-111 structures. Excellent correlation of radiographic images with actual moisture and corrosion damage was attained. Both film and real time/near real time neutron imaging were demonstrated. These results, ...

1983-01-01

383

Comparison of the quality of the chest film between digital radiography and conventional high kV radiography  

International Nuclear Information System (INIS)

Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct ...

2003-02-01

384

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional and CT-scanning ...

1980-10-31

385

Automated segmentation and quantitative characterization of radiodense tissue in digitized mammograms  

International Nuclear Information System (INIS)

Mammography has emerged as a reliable non-invasive technique for the early detection of breast cancer--the second leading cause of cancer-related mortality among American women. The radiographic appearance of the female breast consists of radiolucent (dark) regions due to fat and radiodense (light) regions due to connective and epithelial tissue. The amount of radiodense tissue can be used as a marker for predicting breast cancer risk. This paper presents the development of an algorithm for estimating the percentage of radiodense tissue in a digitized mammogram. The technique involves determining a dynamic threshold for segmenting radiodense indications in mammograms. Both the mammographic image and the threshold are modeled as Gaussian random variables. This work is intended to support a concurrent study at the Fox Chase Cancer Center (FCCC) exploring the association between dietary patterns and breast cancer risk. Mammograms have been obtained from an existing ...

2002-05-25

386

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...

2004-03-21

387

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes in image quality ...

2004-03-21

388

A systematic review to investigate the effectiveness and acceptability of interventions for moist desquamation in radiotherapy patients  

Energy Technology Data Exchange (ETDEWEB)

Aim: To systematically review the currently available high quality evidence evaluating treatments for moist desquamation in radiotherapy patients. Design: Systematic literature review. Methods: Electronic databases, websites, reference lists, key journals and conference proceedings were searched. Attempts were also made to uncover unpublished material. Relevant studies proceeded to data extraction and quality assessment. Results: Twenty studies were found; 10 were eligible for inclusion. Although many studies were small, none had unacceptably poor quality. No meta-analysis was undertaken as the studies were not homogenous in their interventions or methods. No convincing evidence for any intervention was found. Conclusion: Despite being recommended by many guidelines (College of Radiographers Summary of Intervention for Acute Radiotherapy Induced Skin Reactions in Cancer Patients (London, 2001); NHS Quality Improvement Scotland Best Practice Statement: Skincare of ...

2009-08-15

389

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, three-dimensional computer-reconstructed neutron ...

1992-03-01

390

Further development of the unified multiscale Eulerian model for a broad range of spatial and temporal scales within the new National Environmental Modeling System  

Science.gov (United States)

A unified Nonhydrostatic Multiscale Model on the Arakawa B grid (NMMB) designed for a broad range of spatial and temporal scales has been under development within the Earth System Modeling Framework (ESMF) at the National Centers for Environmental Prediction (NCEP) as a part of the new National Environmental Modeling System (NEMS). The model follows the general modeling philosophy of the NCEP's WRF NMM grid-point regional dynamical core. The model uses the regular latitude-longitude grid for the global domain, and a rotated latitude-longitude grid in regional applications. The nonhydrostatic component of the model dynamics is introduced through an add-on module that can be turned on or off depending on resolution. The "isotropic" quadratic conservative finite-volume horizontal differencing employed in the model conserves a variety of basic and derived dynamical and quadratic quantities and preserves some important properties of differential operators. Among these, the conservation of ...

2009-04-01

391

Fatty acid/poly(methyl methacrylate) (PMMA) blends as form-stable phase change materials for latent heat thermal energy storage  

Energy Technology Data Exchange (ETDEWEB)

Fatty acids such as stearic acid (SA), palmitic acid (PA), myristic acid (MA), and lauric acid (LA) are promising phase change materials (PCMs) for latent heat thermal energy storage (LHTES) applications, but high cost is the most drawback which limits the utility area of them in thermal energy storage. The use of fatty acids as form-stable PCM will increase their feasibilities in practical LHTES applications due to reduced cost of the energy storage system. In this regard, a series of fatty acid/poly(methyl methacrylate) (PMMA) blends, SA/PMMA, PA/PMMA, MA/PMMA, and LA/PMMA were prepared as new kinds of form-stable PCMs by encapsulation of fatty acids into PMMA which acts as supporting material. The blends were prepared at different mass fractions of fatty acids (50, 60, 70, 80, and 90% w/w) to reach maximum encapsulation ratio. All blends were subjected to leakage test by heating the blends over the melting temperature of the PCM. The blends ...

2008-02-15

392

Stochastic risk estimation from medical x-ray diagnostic examinations, 3  

International Nuclear Information System (INIS)

The genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemia significant dose (LSD) and malignancy significant dose (MSD) from medical diagnostic X-ray examinations in Japan were estimated based on a 1979 nationwide survey of randomly sampled hospitals and clinics. The population risk estimates were carried out using the resultant values of GSD, LSD and MSD. In the risk estimates, the significant factors, namely, the relative child expectancy, the leukemia significant factor and the malignancy significant factor, for patients were assumed to be same as those of general population. The risk factors used were 185 x 10"-"6 rad"-"1 for genetic risk of all generations, 20 x 10"-"6 rad"-"1 for fatal leukemia and 165 x 10"-"6 rad"-"1 for fatal malignant diseases, respectively. The resultant annual population doses per person were 15 mrad (0.15 mGy) for GSD, 107 mrad (1.07 mGy) for CMD, 86 mrad (0.86 mGy) for LSD and 43 mrad (0.43 mGy) for MSD, respectively. The ...

393

The off-gas cleaning system for gases formed during the vitrification of high-activity wastes from the nuclear power plant A 1  

International Nuclear Information System (INIS)

A multielement apparatus for the removal of aerosols formed in the vitrification of simulated high-activity accident wastes from the decommissioned nuclear power plant A-1 has been designed, manufactured and tested. The apparatus consists of two cooling and condensing steps connected in series, and of five filtration steps also connected in series. The five filtration steps allowed to achieve a decontamination factor of 1x10"5 in the case of removal of a NaCl("2"4Na) testing model aerosol. The decontamination factor for removal of the cesium aerosol by the whole apparatus was 3.3x10"6. In the first filtration step the aerosols are removed by the cartridge with a filtration fabric made of polyethylene fibers, in the second step by the cartridge with a granulated natural material, in the third step by the cartridge with glass-fiber filtration paper, in the fourth and fifth steps by the cartridge with high-efficiency filtration paper made of glass microfibers. In the tube connecting the ...

394

The compressive strength of cement blocks permeated with an organic phase change material  

Energy Technology Data Exchange (ETDEWEB)

The authors investigate the feasibility of constructing walls and partitions with enhanced heat storage capability from cement blocks permeated with an organic phase change material (pressed stearic acid). The blocks are lightweight, easy to produce and are cured in the same way as cement or concrete. The ratio of components (cement, stearic acid (SA) and water) was optimized with respect to compressive strength. With normal portland cement, the best compressive strength 2.2 MPa was obtained with a ratio C:SA:W of 1:0.8:0.65 (i.e. 32% stearic acid) after 28 days of curing. This was increased to 4.4 MPa when high early strength cement was used, about as strong as Sipporex, lightweight concrete or lightweight clay bricks. As expected, the compressive strength decreased linearly with temperature between 25/sup 0/C and 100/sup 0/C, at a rate of 15 kPa//sup 0/C. The drying shrinkage of the modules was found to be 50% greater than for cement mortars. The addition of ...

1984-01-01

395

The TASKA, TDF, and TASKA-M Fusion Neutron Materials Test Facilities  

Science.gov (United States)

This talk will summarize key features of three conceptual fusion neutron test facilities designed in the early 1980s: TASKA,^1 TDF,^2 and TASKA-M.^3 Motivated by the accessibility and maintainability of cylindrical geometry, these magnetic-mirror designs possess a simple central cell, as in a fusion neutron test facility based on the gas dynamic trap (GDT).^4 The TASKA-M design, like today's GDT designs, included the injection of neutral beams into the central cell to create a sloshing-ion distribution that gives density peaks near the materials test modules. In TASKA and TDF, the minimum-B end-cell designs contained thermal barriers, regions of low electrostatic potential to reduce electron flow between central cell and end cells. Thermal barriers improve performance but require more complicated input power systems, and their physics basis is less well established than that of simple mirrors. For TASKA-M, a more conservative design, minimum-B end cells provided MHD stability, but ...

2009-11-01

396

Surface modification of PTFE sheet by synchrotron radiation in the soft X-ray region  

International Nuclear Information System (INIS)

Full text: The surface properties of poly (tetrafluoroethylene) (PTFE) are changed by the exposure to synchrotron radiation (SR). We succeeded in controlling the wettability of the PTFE surface from hydrophobic to hydrophilic by varying the substrate temperature during the SR irradiation and found that the wettability was ascribable to microstructure and chemical composition of surface.In these previous works, oxygen atoms were found to inhabit on the hydrophobic surface of PTFE. In this study, we investigated the surface modification of PTFE from the SR exposure experiment under the O_2 gas atmosphere. The SR exposure to the PTFE sheet was carried out at beamline 6 (BL6) of the New- SUBARU. The PTFE sheet was irradiated to the white beam, ranging 50-1000 eV at BL6 at room temperature. The gas cell was mounted at the irradiation chamber. The O_2 gas pressure in the gas cell can be maintained at about 0.20 Pa during the SR exposure using 5mm #phi# hole window. The ...

2004-07-19

397

Surface modification of 30CrNiMo8 low-alloy steel by active screen setup and conventional plasma nitriding methods  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we report on a comparative study of active screen plasma nitriding (ASPN) and conventional dc plasma nitriding (CPN) behavior of 30CrNiMo8 low-alloy steel that has been examined under various process conditions. The process variables included active screen setup parameters (screen and iron plate top lids placed on the screen setup with 8 mm of hole size), treatment temperature (550 and 580 deg. C), gas mixture (75/25 and 25/75 of N{sub 2}/H{sub 2}) and treatment time (5 and 10 h) in 500 Pa pressure. The structure and phases composition of the diffusion zone and compound layer were studied by X-ray diffraction (XRD), microhardness tests, light optical microscopy and scanning electron microscopy (SEM). It was observed that treated sample surfaces in both CPN and ASPN methods consist of {gamma}' and {epsilon} phases, and while the nitriding time and/or temperature increases, the intensity of {epsilon} phase in the compound layer will increase ...

2007-12-30

398

Surface modification of 30CrNiMo8 low-alloy steel by active screen setup and conventional plasma nitriding methods  

International Nuclear Information System (INIS)

In this paper, we report on a comparative study of active screen plasma nitriding (ASPN) and conventional dc plasma nitriding (CPN) behavior of 30CrNiMo8 low-alloy steel that has been examined under various process conditions. The process variables included active screen setup parameters (screen and iron plate top lids placed on the screen setup with 8 mm of hole size), treatment temperature (550 and 580 deg. C), gas mixture (75/25 and 25/75 of N_2/H_2) and treatment time (5 and 10 h) in 500 Pa pressure. The structure and phases composition of the diffusion zone and compound layer were studied by X-ray diffraction (XRD), microhardness tests, light optical microscopy and scanning electron microscopy (SEM). It was observed that treated sample surfaces in both CPN and ASPN methods consist of #gamma#' and #epsilon# phases, and while the nitriding time and/or temperature increases, the intensity of #epsilon# phase in the compound layer will increase for ASPN and ...

2007-12-30

399

Status and strategies in radioactive waste management in the Russian Federation  

International Nuclear Information System (INIS)

Full text: There are following general tendencies linking to SNF and radioactive waste management (RWM) in the Russian nuclear industry now. The intention to use the closed nuclear fuel cycle based on power water reactors and fast reactor. The intensification of measures aimed at the solution of 'nuclear legacy' from defenses programs of USSR. The intention to improve the existing national RW management infrastructure in the near years by means of the creation of a centralized national system (including managing corporation responsible for operation of long-storage and disposal facilities of conditioned RW). The main aims radioactive waste management (RWM) in nuclear power plants (NPP) for the next 10-15 years are to equip all NPPs with the necessary set of facilities for conditioning of the stored and currently generated RW with packaging the end-product into containers, to build regional NPPs RW repositories and to introduce evaporator bottoms selective purification technology from ...

400

Shell Temperatures for a Single-Heater Diffuser  

Energy Technology Data Exchange (ETDEWEB)

A new diffuser/permeator design has been proposed for a new Savannah River Site tritium project. The use of a single heater well in the center of the shell had raised concerns that the Pd/Ag coils may be shielding radiative heat transfer to the walls thus reducing Pd/Ag tube temperatures near the shell below the recommended minimum operating temperature. The diffuser was fitted with thermocouples to measure shell temperatures during testing. Tests were run with the shell evacuated, helium feed flows of 0, 1000, and 2000 sccm; bleed pressures ranging from 0 to 203 kPa, and heater temperatures of 650, 675, and 700 degrees C. Hydrogen permeation tests were run with two hydrogen/helium mixtures and feed rates to simulate 1st and 2nd stage diffuser operations. Approximately 20 hours were required to bring the diffuser from ambient temperature to steady-state conditions. For tests with a heater temperature of 675 degrees C and no hydrogen flow, helium flow rate and ...

2004-11-01

401

Saddle field fast atom beam source: A new low pressure plasma nitriding method for a alloy Ti-6Al-4V  

Energy Technology Data Exchange (ETDEWEB)

Ti and its alloys (Ti-6Al-4V) have been used in different engineering applications due to their several outstanding properties. Nevertheless, their use in practical applications is limited in many cases due to their poor tribological property. Researches are ongoing on surface modification of Ti based materials by different plasma and ion based techniques to overcome this problem. However, the conventional plasma nitriding techniques have several problems such as formation of an arc, increased possibility of surface contamination due to a comparatively higher operating pressure, production of a very thin nitrided layer after a long processing time, etc. In this present work, the possibility of a new low-pressure plasma nitriding process using a Plasma Enhanced Chemical Vapor Deposition (PECVD) based saddle field fast atom beam source on a Ti-6Al-4V alloy sample is investigated. Plasma nitriding was carried out at 900 deg. C and at a pressure 0.1 Pa for 8 h by using ...

2006-09-25

402

Saddle field fast atom beam source: A new low pressure plasma nitriding method for a alloy Ti-6Al-4V  

International Nuclear Information System (INIS)

Ti and its alloys (Ti-6Al-4V) have been used in different engineering applications due to their several outstanding properties. Nevertheless, their use in practical applications is limited in many cases due to their poor tribological property. Researches are ongoing on surface modification of Ti based materials by different plasma and ion based techniques to overcome this problem. However, the conventional plasma nitriding techniques have several problems such as formation of an arc, increased possibility of surface contamination due to a comparatively higher operating pressure, production of a very thin nitrided layer after a long processing time, etc. In this present work, the possibility of a new low-pressure plasma nitriding process using a Plasma Enhanced Chemical Vapor Deposition (PECVD) based saddle field fast atom beam source on a Ti-6Al-4V alloy sample is investigated. Plasma nitriding was carried out at 900 deg. C and at a pressure 0.1 Pa for 8 h by using ...

2006-09-25

403

Reactive magnetron sputtering of hard Si-B-C-N films with a high-temperature oxidation resistance  

International Nuclear Information System (INIS)

Based on the results obtained for C-N and Si-C-N films, a systematic investigation of reactive magnetron sputtering of hard quaternary Si-B-C-N materials has been carried out. The Si-B-C-N films were deposited on p-type Si(100) substrates by dc magnetron co-sputtering using a single C-Si-B target (at a fixed 20% boron fraction in the target erosion area) in nitrogen-argon gas mixtures. Elemental compositions of the films, their surface bonding structure and mechanical properties, together with their oxidation resistance in air, were controlled by the Si fraction (5-75%) in the magnetron target erosion area, the Ar fraction (0-75%) in the gas mixture, the rf induced negative substrate bias voltage (from a floating potential to -500 V) and the substrate temperature (180-350 deg. C). The total pressure and the discharge current on the magnetron target were held constant at 0.5 Pa and 1 A, respectively. The energy and flux of ions bombarding the growing films were ...

2005-11-01

404

RangerMaster{trademark}: Real-time pattern recognition software for in-field analysis of radiation sources  

Energy Technology Data Exchange (ETDEWEB)

RangerMaster{trademark} is the embedded firmware for Quantrad Sensor`s integrated nuclear instrument package, the Ranger{trademark}. The Ranger{trademark}, which is both a gamma-ray and neutron detection system, was originally developed at Los Alamos National Laboratory for in situ surveys at the Plutonium Facility to confirm the presence of nuclear materials. The new RangerMaster{trademark} software expands the library of isotopes and simplifies the operation of the instrument by providing an easy mode suitable for untrained operators. The expanded library of the Ranger{trademark} now includes medical isotopes {sup 99}Tc, {sup 201}Tl, {sup 111}In, {sup 67}Ga, {sup 133}Xe, {sup 103}Pa, and {sup 131}I; industrial isotopes {sup 241}Am, {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 40}K, {sup 60}Co, {sup 232}Th, {sup 226}Ra, and {sup 207}Bi; and nuclear materials {sup 235}U, {sup 238}U, {sup 233}U, and {sup 239}Pu. To accomplish isotopic identification, a simulated ...

1998-12-31

405

Performance objectives for the Hanford immobilized low-activity waste (ILAW) performance assessment  

Energy Technology Data Exchange (ETDEWEB)

Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a DOE 1999a) require the protection of public health and safety; and the protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mrem/year), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance assessments, interacting with program management to establish the additional requirements of the program, and interacting with the public (i.e., the Hanford ...

1999-09-09

406

PSA methodology including new design, operational and safety factors, 'Level of recognition of phenomena with a presumed dominant influence upon operational safety' (failures of conventional as well as non-conventional passive components, dependent failures, influence of operator, fires and external threats, digital control, organizational factors)  

International Nuclear Information System (INIS)

The document represents a specific type of discussion of existing methodologies for the creation and application of probabilistic safety assessment (PSA) in light of the EUR document summarizing requirements placed by Western European NPP operators on the future design of nuclear power plants. A partial goal of this discussion consists in mapping, from the PSA point of view, those selected design, operational and/or safety factors of future NPPs that may be entirely new or, at least, newly addressed. Therefore, the terms of reference for this stage were formulated as follows: Assess current level of knowledge and procedures in the analysis of factors and phenomena with a dominant influence upon operational safety of new generation reactors, especially in the following areas: (1) Phenomenology of failure types and mechanisms and reliability of conventional passive safety system components; (2) Phenomenology of failure types and mechanisms and reliability of non-conventional passive ...

407

Monitoring, sampling and analysis of fine particulates -- Results and experiences from DOE's Federal Energy Technology Center  

Energy Technology Data Exchange (ETDEWEB)

The overall goal of the DOE fine particulate program is to ensure that the best science and technology is available for any regulatory decision-making related to the health and environmental impacts of ambient fine particulate matter and regional haze. Interest primarily lies in the particulate fraction having aerodynamic diameters of 2.5 microns and less (PM2.5). Particulates of this size are the focus of the newly established National Ambient Air Quality Standards. As such, the Federal Energy Technology Center (FETC) is establishing a fine particulate sampling station at the Center's Pittsburgh site located in South Park Township, PA. This sampling station is one of a group of stations scattered throughout Pennsylvania, West Virginia, and Ohio that constitute the Upper Ohio River Valley Project. The station is equipped with a full complement of fine particulate and gaseous monitors including the following: (1) R and P Sequential FRM sampler, (2) Grimm ...

1999-07-01

408

Milliampere class Si{sup -} or B{sup -} negative ion extraction from RF plasma sputter type heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} current of 3.8 mA and ...

1993-12-31

409

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that determined by other authors. Our results show that a treatment planning system designed for ...

2001-02-01

410

Integrated well-completion strategies with CHOPS to enhance heavy-oil production : a case study in Fula Oilfield  

Energy Technology Data Exchange (ETDEWEB)

Cold Heavy Oil Production with Sand (CHOPS) is an enhanced oil recovery method that induces sand production to form a network of wormholes that increase the porosity and permeability of a formation. Under proper conditions, CHOPS can improve formation flow characteristics. Integrated well completion strategies that were used to increase oil production at Fula oil field on the south flank of Mughad Basin in Sudan were described. Limited sand influx provided a means for effective sand control while eliminating the need for conventional sand control processes. Cold heavy oil production with limited sand influx requires optimized completion methods to stimulate sand production, thereby reducing oil flow resistance and prolonging the sand removal operation cycle. Completion tests were performed in terms of different formation conditions including perforating completion; perforating and full sand control completion by screen liner; and perforating and limited sand control completion by ...

2005-11-01

411

High-power, high-brightness pseudospark-produced electron beam driven by improved pulse line accelerator  

Energy Technology Data Exchange (ETDEWEB)

A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10{sup 10}A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its various electrodes and insulators. But on almost all the surfaces ...

1995-12-31

412

Graded layer design for stress-reduced and strongly adherent superhard amorphous carbon films  

Energy Technology Data Exchange (ETDEWEB)

Diamond-like carbon thin films for tribological applications were deposited by d.c.-magnetron sputtering of a graphite target in a pure argon atmosphere or in a reactive hydrogen or methane atmosphere at pressures between 0.1 and 1 Pa in a graded constitution to improve adhesion and reduce residual stress. The temperature of the metallic, carbon- and ceramic-like substrates was below 100 C. The mechanical, thermal, electronic and optical properties of the carbon thin films show a significant dependence on the ion energy. Below 220 eV, strongly adherent black conductive films with hardness values up to 2000 HV0.05 were obtained. Hard and superhard diamond-like carbon thin films were deposited in an energy range between 220 and 370 eV with hardness values up to 4000 HV0.05. They are insulating, optically transparent and show a high degree of hardness combined with high compressive stress in the order of 4 GPa as well as a low adhesion, which means that the critical ...

1999-09-01

413

Focused ion beam assisted three-dimensional rock imaging at submicron scale  

Energy Technology Data Exchange (ETDEWEB)

Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 micrometers and as thin as 100 nanometers by sputtering of atoms from the sample surface. The focused ion beam, consisting of gallium ions (Ga+) accelerated by potentials of up to 30 kV and currents up to 20,000 ...

2003-05-09

414

Evaluation of an eastern shale oil residue as an asphalt additive  

Energy Technology Data Exchange (ETDEWEB)

An evaluation of eastern shale oil (ESO) residue as an asphalt additive to reduce oxidative age hardening and moisture susceptibility was conducted by Western Research Institute (WRI). The ESO residue, have a viscosity of 23.9 Pa{lg_bullet}s at 60{degree}C (140{degree}F), was blended with three different petroleum-derived asphalts, ASD-1, AAK-1, and AAM-1, which are known to be very susceptible to oxidative aging. Rheological and infrared analyses of the unaged and aged asphalts and the blends were then conducted to evaluate oxidative age hardening. In addition, the petroleum-derived asphalts and the blends were coated onto three different aggregates, Lithonia granite (RA), a low-absorption limestone (RD), and a siliceous Gulf Coast gravel (RL), and compacted into briquettes. Successive freeze-thaw cycling was then conducted to evaluate the moisture susceptibility of the prepared briquettes. The rheological analyses of the unaged petroleum-derived asphalts and ...

1995-09-01

415

Electron cyclotron heating  

International Nuclear Information System (INIS)

Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented by heating in the vicinity of the q = 1 ...

416

Development of an Eastern Shale Oil Residue as an Asphalt Additive - Subtask 2.5: Topical report, February 1, 1994-February 1, 1995  

Science.gov (United States)

An evaluation of eastern shale oil as an asphalt additive to reduce oxidative age hardening and moisture susceptibility is being conducted. An eastern shale oil residue having a viscosity of 1.30 Pa`s at 60{degrees}C (140{degrees}F) was blended with three different petroleum-derived asphalts that are known to be very susceptible to oxidative aging. In addition, blends of the eastern shale oil residue and the petroleum-derived asphalts are being coated onto three different aggregates that are known to be susceptible to water stripping. The oxidative age hardening portion of this study is not complete at this time. To date, information has been obtained on the unaged samples and two of the aged petroleum-derived asphalts (AAD-1 and AAK-1). When complete, this data will include rheological data on the unaged, RTFO-aged, and the RTFO/PAV-aged samples and infrared data on the unaged and RTFO/PAV-aged samples. With respect to the rheological data, asphalt AAD-1 meets the ...

1997-12-31

417

Development of a Bragg curve spectrometer (BCS) for fragment spectroscopy from neutron and proton induced reactions  

Energy Technology Data Exchange (ETDEWEB)

Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the saturation property by using {sup 241}Am {alpha} ...

2002-09-01

418

An experimental investigation on engine performance and emissions of a supercharged H{sub 2}-diesel dual-fuel engine  

Energy Technology Data Exchange (ETDEWEB)

This study investigated the engine performance and emissions of a supercharged engine fueled by hydrogen and ignited by a pilot amount of diesel fuel in dual-fuel mode. The engine was tested for use as a cogeneration engine, so power output while maintaining a reasonable thermal efficiency was important. Experiments were carried out at a constant pilot injection pressure and pilot quantity for different fuel-air equivalence ratios and at various injection timings without and with charge dilution. The experimental strategy was to optimize the injection timing to maximize engine power at different fuel-air equivalence ratios without knocking and within the limit of the maximum cylinder pressure. The engine was tested first with hydrogen-operation condition up to the maximum possible fuel-air equivalence ratio of 0.3. A maximum IMEP of 908 kPa and a thermal efficiency of about 42% were obtained. Equivalence ratio could not be further increased due to knocking of the ...

2010-01-15

419

All focused ion beam fabricated MgB_2 inter-grain nanobridge dc SQUIDs  

International Nuclear Information System (INIS)

We have fabricated MgB_2 dc SQUIDs (superconducting quantum interference devices) containing inter-grain nanobridges as Josephson elements by a focused ion beam (FIB) etching method and measured their transport properties. The entire structure including the SQUID loop was patterned only using a FIB. The beam energy was 30 kV and the current was 0.9 nA for larger structures and 34 and 1.5 pA for the nanobridge pattern. Each bridge with a nominal width of 100 nm crossed a single grain boundary in the normal direction. The SQUID loop had a 3.1 #mu#m x 3.1 #mu#m hole with a 2 #mu#m average linewidth, corresponding to an inductance of 5.1 pH. The nanobridges had a two-step transition with an increase in the resistivity of more than a decade and a substantial decrease in the critical current density. Current-voltage characteristics showed a resistively shunted junction behavior at all temperatures below T_c, which implies that the current in the inter-grain nanobridges ...

2009-06-01

420

Water diffusion profile measurements in epoxy using neutron radiography  

International Nuclear Information System (INIS)

The diffusion characteristics of water in polymer materials have been studied for a few decades. Several methods have been developed to provide water diffusion characteristics as a function of time, temperature, pressure, or thickness of polymer. Unfortunately, most of these methods give the amount of water absorbed as a function of weight versus time at given environmental conditions. Concentration profiles of the water diffusion through the polymer have been unobtainable by these established methods. Neutron radiography is a method of non-destructive testing that has grown rapidly over the past ten years and is capable of giving these concentration profiles. Epoxy is one of the most commonly used polymers for which water diffusion information is important. In the automotive industry, epoxy is used both as a sealant and a bonder to prevent water from getting inside structures and causing corrosion. To prevent this corrosion, it is important to know the diffusion behavior of water in ...

421

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water temperature to the ...

1998-02-01

422

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

International Nuclear Information System (INIS)

Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam-water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two-phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 MW TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water temperature to the test section ...

1999-11-03

423

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

International Nuclear Information System (INIS)

Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water temperature to the ...

1998-03-16

424

Understanding feline heartworm infection: disease, diagnosis, and treatment.  

Science.gov (United States)

Feline heartworm disease is a very different clinical entity from canine heartworm disease. In cats, the arrival and death of immature heartworms in the pulmonary arteries can cause coughing and dyspnea as early as 3 months postinfection. Adult heartworms suppress the function of pulmonary intravascular macrophages and thus reduce clinical disease in chronic feline heartworm infection. Approximately 80% of asymptomatic cats self-cure. Median survival time for symptomatic cats is 1.5 years, or 4 years if only cats living beyond the day of presentation are considered. Aberrant worm migration is more frequent than it is in dogs, and sudden death can occur with no prior clinical signs. The bacterial endosymbiont Wolbachia likely contributes to the inflammatory pathology of heartworm disease, but its role is not yet fully clear. Unfortunately, the diagnosis, treatment, and management of feline heartworm disease are far from simple. Antemortem diagnosis is hampered by low worm burdens, the ...

2010-11-01

425

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as alternative non-invasive ...

2003-07-01

426

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the ...

1994-10-01

427

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the ...

1994-01-01

428

Respiratory impairment due to asbestos exposure in brake-lining workers  

International Nuclear Information System (INIS)

There is extensive evidence that exposure to asbestos causes pulmonary parenchyma fibrosis, pleural disease, and malignant neoplasm in asbestos-exposed workers. However, few data concerning brake-lining workers are available in the literature. In this study, we aimed to assess the long-term effects of chrysotile asbestos exposure on lung function and the risk of asbestos-related diseases in brake-lining workers. Seventy-four asbestos-exposed workers who processed brake-lining products and 12 unexposed office workers were offered pulmonary function tests (spirometry and transfer actor) in 1992 and 1999. In 1999, the mean duration of asbestos exposure was 0.00#+-#4.07 and 11.02#+-#4.81 years (7-31 years) in non smoking and smoking asbestos workers, respectively. Transfer factor (T_L, CO) and transfer coefficient (K_C_O) decline were significant in the 7-year follow-up in both smoking and non smoking asbestos workers. However, lung function indices of he control group, whom were all ...

2003-03-01

429

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the non-destructive evaluation (NDE) of carbon fiber ...

2001-07-01

430

Radiological protection. Textbook for radiographers and reference book for radiological safety officers; Strahlenschutz. Lehrbuch fuer Personen, die nach den Bestimmungen der Roentgenverordnung vom 8. Januar 1987 als medizinisch-technische Radiologieassistenten taetig sind und zur Unterweisung fuer Strahlenschutzbeauftragte  

Energy Technology Data Exchange (ETDEWEB)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe) [Deutsch] Das vorliegende Lehrbuch, das sich vor allem an das technische Personal und an Strahlenschutzbeauftragte wendet, unterrichtet ueber die derzeit gueltigen Bestimmungen der Roentgenverordnung, die Anwendung von Roentgenstrahlen, ueber Qualitaetssicherung, die Organisation der Filmverarbeitung sowie ueber die Anforderungen an die Qualitaet von Roentgenbildern. Im ...

1996-12-31

431

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well defined in four out of the six patients. Four ...

2005-09-01

432

Physics and quality assurance of low dose rate brachytherapy  

International Nuclear Information System (INIS)

Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, personnel, and the institution (2) QA procedure development: forms, checklists, test ...

433

Performance study of teleradiology network systems with CRT monitors. ROC analysis of an observation study of simulated lung nodules  

International Nuclear Information System (INIS)

To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to indicate the presence or absence of ...

434

Osteonecrosis of the hip joint in adults; Die Osteonekrose des Hueftgelenks im Erwachsenenalter  

Energy Technology Data Exchange (ETDEWEB)

Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computed tomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten bei der ON wurden in den letzten Jahren durch technische Fortschritte bei den ...

2002-06-01

435

Normal development of paranasal sinuses in children: A CT study  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the normal development of the paranasal sinuses in children with CT, authors prospectively studied with brain CT scans of 260 children without known sinus disease, ranging image from 7 days to 16 years. Maximal anteroposterior and transverse diameters(mm) and maximal cross- sectional area(mm{sup 2}) of both sides of the maxillary sinus were measured with the aid of computer device. As to the ethmoidal and spheroidal sinuses, we simply documented the presence of the aplastic ethmoidal sinus and calculated the age-incidence of the spheroidal sinus pneumatization, respectively.There noted three phases in the development of the maxillary sinus. The anteroposterior and transverse diameters of the maxillary sinus increased nearly in parallel. The former was always greater than the latter. In no cases was the edathamil sinus aplastic and almost all sinuses were pneumatized even in infants as early as 7 old days. CT identified the conchal pattern of sphenoidal sinus pneumatization ...

1993-11-15

436

Natural background radiation induces cytogenetic radioadaptive response more effectively than occupational exposure in human peripheral blood lymphocytes  

Science.gov (United States)

Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood samples were prepared and exposed to challenge dose of 0 and 2 Gy. Lymphocytes were scored using analysis of metaphase, for the presence of ...

2003-01-01

437

Lung irradiation for Ewing's sarcoma with pulmonary metastases at diagnosis: results of the CESS-studies  

International Nuclear Information System (INIS)

Background: In the German CESS-studies, Ewing's sarcoma patients with pulmonary metastases at diagnosis were considered as candidates for additional bilateral lung irradiation. We have retrospectively analyzed the impact of radiotherapy on survival. Material and methods: Out of 42 patients presenting with pulmonary metastases of Ewing's sarcoma between 1981 and June 1992, 30 were evaluable. One patient died of progressive disease prior to lung irradiation. The other patients had a complete radiographic remission either after chemotherapy (n=25) or chemotherapy plus resection of lung metastases (n=4). 22 patients received bilateral lung irradiation with doses of 12 to 21 Gy (once daily 1.5 Gy or twice daily 1.25 Gy), six had no further treatment and one had bone marrow transplantation for consolidation. Results: Ten patients are in complete remission, nine of them had received lung irradiation and one had a complete resection of three lung metastases. Two patients ...

438

Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine  

International Nuclear Information System (INIS)

The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning size, position and ...

1995-10-01

439

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital ...

2003-03-15

440

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital ...

2003-03-01

441

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 non-calcified nodules), in which calcification was diagnosed by ...

1995-08-01

442

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 non-calcified nodules), in which calcification was diagnosed by computed ...

1995-01-01

443

Corrected transposition of the great arteries  

International Nuclear Information System (INIS)

The corrected transposition of the great arteries is an usual congenital cardiac malformation, which consists of transposition of great arteries and ventricular inversion, and which is caused by abnormal development of conotruncus and ventricular looping. High frequency of associated cardiac malformations makes it difficult to get accurate morphologic diagnosis. A total of 18 cases of corrected transposition of the great arteries is presented, in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between September 1976 and June 1981. The clinical, radiographic, and operative findings with the emphasis on the angiocardiographic findings were analyzed. The results are as follows: 1. Among 18 cases, 13 cases have normal cardiac position, 2 cases have dextrocardia with situs solitus, 2 cases have dextrocardia with situs inversus and 1 case has levocardia with situs inversus. 2. Segmental sets ...

1981-12-01

444

Computed Tomography diagnosis of skeletal involvement in multiple myeloma  

International Nuclear Information System (INIS)

The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous ...

1994-06-01

445

Clinical use of lipiodol in hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol, lipid soluble contrast media, was applied to 59 patients, who was clinically suspected to have hepatic tumor, in the Department of Diagnostic Radiology, Seoul National University Hospital. The results of the clinical use of Lipiodol were as follows: 1. The clinical diagnosis was hepatocellular carcinoma (HCC) in 50 cases, cavernous hemangioma in 4 cases, metastasis in one case and others in 4 cases. 2. After hepatic arteriography, Lipiodol only was injected in 28 cases, mixture of Lipiodol and Mitomycin was injected in 22 cases and transcatheter arterial embolization was performed additionally after injection of Lipiodol and Mitomycin in 9 cases. 3. Among the 50 cases of HCC, Lipiodol was accumulated in the lesion in 49 cases. However, similar accumulation of Lipiodol occured in a metastatic cancer and cavernous hemangiomas. 4. Plain radiographic patterns of Lipiodol accumulation could be divided into fine granular type, nodular type and linear or ...

1986-08-15

446

Cardiac Malpositions  

International Nuclear Information System (INIS)

Cardiac Malposition refers to any position of the heart other than a left-sided heart in a situs solitus individual. Associated cardiac malformations are so complex that even angiocardiographic and autopsy studies may not afford an accurate information. Although the terms and classifications used to describe the internal cardiac anatomy and their arterial connections in cardiac malpositions differ and tend to be confusing, common agreement exists on the need for a segmental approach to diagnosis. Authors present 18 cases of cardiac malpositions in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between 1971 and 1979. Authors analyzed the clinical, radiographic, operative and autopsy findings with the emphasis on the angiocardiographic findings. The results are as follows: 1. Among 18 cases with cardiac malpositions, 6 cases had dextrocardia with situs inversus, 9 cases had dextrocardia ...

1979-06-01

447

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia; Aspetti alla tomografia computerizzata dell'infarto intestinale. 56 pazienti sottoposti a interventi chirurgico di cui 5 con ischemia mesenterica reversibile.  

Energy Technology Data Exchange (ETDEWEB)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e tipica del soggeto anziano; nonostante il notevole ...

1999-04-01

448

Analyses of superficial and depth doses in intraoral radiology  

Energy Technology Data Exchange (ETDEWEB)

In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The ...

2006-07-01

449

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography  

International Nuclear Information System (INIS)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower lobe. Bilateral ...

2000-06-01

450

WLUP3.0, 69 and 172 Group Cross Section Libraries for WIMS  

International Nuclear Information System (INIS)

Description or function: WLUP contains validated WIMS-D formatted cross section libraries in 69 and 172 energy group structures for nuclear reactor calculations. Materials from recently released evaluated nuclear data libraries are included. The NJOY nuclear data processing system was applied for generating the cross section files following the models and conventions built into the WIMS-D lattice code. The relevant features for the WIMS users are: - Energy group structures: 69 and 172 energy groups. - List of materials: WIMS ID, general information, source of data. - Cross sections: 69 and 172 group plots. - Resonance data: WIMS ID, temperature, background cross sections. - Goldstein-Cohen factors: Goldstein-Cohen lambda values. - Thermal scattering data: thermal scattering laws and P1 matrixes. - Fission spectrum: fission spectrum data. - Burnup data: burnup chains. - Fission product yields: fission yield tables. - Pseudo lumped fission product: Description of pseudo fission product. ...

451

ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation  

International Nuclear Information System (INIS)

Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, 45Rh-103M, 45Rh-105M, 45Rh-105, 45Rh-106, ...

452

Steady-state and transient photoconductivity in c-axis GaN nanowires grown by nitrogen-plasma-assisted molecular beam epitaxy  

International Nuclear Information System (INIS)

Analysis of steady-state and transient photoconductivity measurements at room temperature performed on c-axis oriented GaN nanowires yielded estimates of free carrier concentration, drift mobility, surface band bending, and surface capture coefficient for electrons. Samples grown (unintentionally n-type) by nitrogen-plasma-assisted molecular beam epitaxy primarily from two separate growth runs were examined. The results revealed carrier concentration in the range of (3-6)x10"1"6 cm"-"3 for one growth run, roughly 5x10"1"4-1x10"1"5 cm"-"3 for the second, and drift mobility in the range of 500-700 cm"2/(V s) for both. Nanowires were dispersed onto insulating substrates and contacted forming single-wire, two-terminal structures with typical electrode gaps of #approx =#3-5 #mu#m. When biased at 1 V bias and illuminated at 360 nm (3.6 mW/cm"2) the thinner (#approx =#100 nm diameter) nanowires with the higher background doping showed an abrupt increase in photocurrent from 5 ...

2010-02-01

453

Nevada Test Site, 2006 Waste Management Monitoring Report, Area 3 and Area 5 Radioactive Waste Management Sites  

Science.gov (United States)

Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no detectable man-made radioactivity by gamma spectroscopy, and ...

2007-06-30

454

Early Pulomonary Irradiation in Paraquat (Gramoxone) Poisoning  

Energy Technology Data Exchange (ETDEWEB)

Purpose : To evaluate whether the early pulmonary irradiation can prevent or decrease the pulmonary damage and contribute to improve ultimate survival in paraquat lung. Materials and Methods : From Jun. 1987 to Aug. 1993, thirty patients with paraquat poisoning were evaluated. Fourteen of these patients were received pulmonary irradiation(RT). All of the patients ere managed with aggressive supportive treatment such as gastric lavage, forced diuresis, antioxidant agents and antifibrosis agents. Ingested amounts of paraquat were estimated into three groups(A: minimal < about 5cc, B: mouthful 5-50 cc, C: Large > 50cc). Pulmonary irradiation was started within 24 hours after admission(from day 1 to day 11 after ingestion of paraquat). Both whole lungs were irradiated with AP/PA parallel opposing fields using C0-60 teletherapy machine. A total of 10Gy(2Gy/fr. X 5 days)was delivered without correction of lung density. Results : In group A, all patients ...

1995-12-15

455

Aespoe Task Force on modelling of groundwater flow and transport of solutes. Review of Task 6C  

Energy Technology Data Exchange (ETDEWEB)

This report forms part of an independent review of the specifications, execution and results of Task 6 of the Aespoe Task Force on Modelling of Groundwater Flow and Transport of Solutes, which is seeking to provide a bridge between site characterization (SC) and performance assessment (PA) approaches to solute transport in fractured rock. The present report is concerned solely with Task 6C, which relates to the construction and parametrisation of a block-scale hydrostructural model of the TRUE Block Scale region of the Aespoe Hard Rock laboratory. The task objectives, specifications and outcome are summarised and reviewed. Also, consideration is given to how the hydrostructural model might affect the outcomes of Task 6D and 6E. The main conclusions of this review are summarised below: The Task 6C hydrostructural model is a more comprehensive approach to quantitatively describing a volume of fractured rock than has been achieved hitherto. The idea of including ...

2005-03-01

456

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy; Die Stadienbestimmung der Osteochondrosis dissecans am Knie- und Sprunggelenk mit der MRT. Vergleich mit konventioneller Radiologie und Arthroskopie  

Energy Technology Data Exchange (ETDEWEB)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T{sub 1}- and T{sub 2}-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG) [Deutsch] In einer prospektiven Studie an 50 Patienten mit einer Osteochondrosis dissecans (OD) des Knie- und ...

1995-07-01

457

Primary Ewing's sarcoma of the vertebral column  

International Nuclear Information System (INIS)

To determine the demographics, imaging findings, clinical symptoms, and prognosis of primary vertebral Ewing's sarcoma (PVES). A retrospective review of medical records and radiological studies of patients diagnosed with PVES from 1936 through 2001 in our institution and Department of Pathology consultation files was undertaken. Metastatic and soft tissue Ewing's sarcoma cases were excluded. From a total of 1,277 cases of Ewing's sarcoma, 125 (9.8%) had a primary vertebral origin. There were 48 females and 76 males. Patient ages ranged from 4 to 54 (mean 19.3, standard deviation 10.7, median 16) years. Vertebral column distribution was four cervical (3.2%), 13 thoracic (10.5%), 31 lumbar (25%), and 67 sacrum (53.2%). More than one vertebral segment was involved in ten cases (8%). Satisfactory imaging studies were available in 51 patients: 49 radiographs, 27 computerized tomography (CT), and 23 magnetic resonance imaging (MRI) studies. The majority of tumors were ...

2004-09-01

458

Percutaneous transhepatic biliary drainage for hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with stent in stent, 1 case was placed with three stents, and 3 ...

2007-10-01

459

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose and profiles for reference fields and ...

2006-02-07

460

Ionospheric response to the phenomena occurring below and above it: a summary  

Energy Technology Data Exchange (ETDEWEB)

Some of well known F{sub 2} layer anomalies might have their origin in lower atmosphere and some have extra terrestrial sources. It has been suggested that the phenomena occurring below the ionosphere such as thunderstorms, lightning/sprites, volcanic eruptions and earthquakes and above the phenomena like corona mass ejection, solar flares and extra terrestrial events may produce F{sub 2} layer signatures. In the present paper we have tried to summarize the effect of some phenomena occurring below the ionosphere like thunderstorms, lightning/sprites and seismic activity and the phenomena such as solar flares which occur above the ionosphere, on the ionospheric electron and ion temperatures. The paper also discusses possibilities. The ionospheric electron and ion temperatures were measured by the RrPAa payload aboard the Iindian SRrOSS-C2 satellite. The normal day's ion and electron temperatures have been compared to the temperatures recorded during the disturbed day. The ...

2009-01-15

461

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and a similar flow channel with an internal ...

1346-01-01

462

Soft tissue manifestations of early rheumatic disease. Imaging with MRI; Fruehmanifestationen rheumatischer Gelenkerkrankungen an den Weichgewebestrukturen der Hand. Nachweis mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a particular rheumatic disease (PsA; r=0.934; ...

2006-08-15

463

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters; Digitale Vergroesserungsmammographie mit Speicher-Folien-Technik. Standardisierte und befundorientierte Bildverarbeitungsparameter  

Energy Technology Data Exchange (ETDEWEB)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as microcalcifications. The introduction of the storage ...

1997-05-01

464

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...

2000-12-01

465

ZZ MCB-JEF2.2, MCB Continuous-Energy Neutron Cross Section Libraries for Temperatures from 300 to 1800 K  

International Nuclear Information System (INIS)

1 - Description of program or function: MCB-JEF2.2 is a continuous-energy cross section libraries in ACE Format suitable for the MCB-1C and MCNP codes. Libraries for various materials were generated at six different Temperatures, and cover the energy range up to 20 MeV. Format: ACE. Number of groups: Continuous energy. Nuclides: H-1, H-2, H-3, He-3, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat., N-14, N-15, O-16, O-17, Na-23, F-19, Mg-nat., Al-27, Si-nat., P-31, S-32, S-33, S-34, S-36, Cl-nat, K-nat, Ca-nat., Ti-nat, V-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-59, Ni-60, Ni-61, Ni-62, Ni-64, Cu-nat, Ga-nat, Ge-72, Ge-73, Ge-74, Ge-76, As-75, Se-74, Se-76, Se-77, Se-78, Se-80, Se-82, Br-79, Br-81, Kr-78, Kr-80, Kr-82, Kr-83, Kr-84, Kr-85, Kr-86, Rb-85, Rb-86, Rb-87, Sr-84, Sr-86, Sr-87, Sr-88, Sr-89, Sr-90, Y-89, Y-90, Y-91, Zr-nat, Zr-90, Zr-91, Zr-92, Zr-93, Zr-94, Zr-95, Zr-96, Nb-93, Nb-94, Nb-95, Mo-nat, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, ...

466

ZZ KASHIL-E6, 175 N, 42 Gamma Groups Cross Sections in MATXS Format Based on ENDF/B-VI.5 for Shielding Applications  

International Nuclear Information System (INIS)

1 - Description of program or function: Format: MATXS; Number of groups: 175 neutron-, 42 photon-groups; 176 Nuclides: 1-H-1, 1-H-2, 1-H-3, 2-He-3, 2-He-4, 3-Li-6, 3-Li-7, 4-Be-9, 5-B-10, 5-B-11, 6-C- nat., 7-N-14, 7-N-15, 8-O-16, 8-O-17, 9-F-19, 11-Na-23, 12-Mg-nat., 13-Al-27, 14-Si-nat., 14-Si-28, 14-Si-29, 14-Si-30, 15-P-31, 16-S-32, 17-Cl-nat., 19-K-nat., 20-Ca-nat., 21-Sc-45, 22-Ti-nat., 23-V-nat., 24-Cr-50, 24-Cr-52, 24-Cr-53, 24-Cr-54, 25-Mn-25, 26-Fe-54, 26-Fe-56, 26-Fe-57, 26-Fe-58, 27-Co-59, 28-Ni-58, 28-Ni-60, 28-Ni-61, 28-Ni-62, 28-Ni-64, 29-Cu-63, 29-Cu-65, 31-Ga-nat., 39-Y-89, 40-Zr-nat., 40-Zr-90, 40-Zr-91, 40-Zr-92, 40-Zr-94, 40-Zr-96, 41-Nb-93, 42-Mo-nat., 46-Pd-102, 46-Pd-104, 46-Pd-105, 46-Pd-106, 46-Pd-108, 46-Pd-110, 47-Ag-107, 47-Ag-109, 48-Cd-106, 48-Cd-108, 48-Cd-110, 48-Cd-112, 48-Cd-113, 48-Cd-114, 48-Cd-116, 49-In-nat., 53-I-127, 54-Xe-124, 54-Xe-126, 54-Xe-128, 54-Xe-129, 54-Xe-130, 54-Xe-131, 54-Xe-132, 54-Xe-134, 54-Xe-136, 55-Cs-133, 56-Ba-138, 59-Pr-141, ...

467

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a ...

2000-09-01

468

ZZ KAFAX-F22, 80 and 24 Groups Cross-Section Library in MATXS Format Based on JEF-2.2 for Fast Reactors  

International Nuclear Information System (INIS)

1 - Description: Format: MATXS. Number of groups: 80 neutron-, 24 photon-groups. 97 Nuclides: 1-H-1, 1-H-2, 2-He-3, 2-He-4, 3-Li-6, 3-Li-7, 4-Be-9, 5-B-10, 5-B-11, 6-C- nat., 7-N-14, 7-N-15, 8-O-16, 9-F-19, 11-Na-23, 12-Mg-nat., 13-Al-27, 14-Si-nat., 15-P-31, 17-Cl-nat., 18-Ar-40, 19-K-nat., 20-Ca-nat., 22-Ti-nat., 23-V-nat., 24-Cr-50, 24-Cr-52, 24-Cr-53, 24-Cr-54, 25-Mn-25, 26-Fe-54, 26-Fe-56, 26-Fe-57, 26-Fe-58, 27-Co-59, 28-Ni-58, 28-Ni-60, 28-Ni-61, 28-Ni-62, 28-Ni-64, 29-Cu-nat., 31-Ga-nat., 39-Y-89, 40-Zr-nat., 41-Nb-93, 42-Mo-nat., 47-Ag-107, 47-Ag-109, 48-Cd-nat., 50-Sn-nat., 63-Eu-151, 63-Eu-153, 64-Gd-152, 64-Gd-154, 64-Gd-155, 64-Gd-156, 64-Gd-157, 64-Gd-158, 64-Gd-160, 73-Ta-181, 74-W-182, 74-W-183, 74-W-184, 74-W-186, 75-Re-185, 75-Re-187, 79-Au-197, 82-Pb-nat., 83-Bi-209, 90-Th-232, 91-Pa-233, 92-U-232, 92-U-233, 92-U-234, 92-U-235, 92-U-236, 92-U-237, 92-U-238, 93-Np-237, 93-Np-238, 94-Pu-238, 94-Pu-239, 94-Pu-240, 94-Pu-241, 94-Pu-242, 95-Am-241, ...

469

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. Besides an ...

2006-11-13

470

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography; Sindrome da immunodeficienza acquisita e malattie polmonari da Mycobacterium xenopi. Ruolo della Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with aspecific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower lobe. Bilateral ...

2000-06-01