International Nuclear Information System (INIS)
Off-axis electron holography is used to characterize a linear array of transistors, which was prepared for examination in cross-sectional geometry in the transmission electron microscope (TEM) using focused ion beam (FIB) milling from the substrate side of the semiconductor device. The measured electrostatic potential is compared with results obtained from TEM specimens prepared using the more conventional 'trench' FIB geometry. The use of carbon coating to remove specimen charging effects, which result in electrostatic fringing fields outside 'trench' specimens, is demonstrated. Such fringing fields are not observed after milling from the substrate side of the device. Analysis of the measured holographic phase images suggests that the electrically inactive layer on the surface of each FIB-milled specimen typically has a thickness of 100 nm.
2005-04-01
An off-axis Cassegrain optimal design for short focal length parabolic solar concentrators
Energy Technology Data Exchange (ETDEWEB)
The present work addresses an off-axis Cassegrain optical concentration system. The specific primary collector analyzed, a short focal length parabolic concentrator, is at the University of Florida`s Energy Park. A secondary hyperbolic reflective element was designed to redirect the solar radiation from the primary focal plane to an off-axis target on the polar axis of the primary concentrator. This ground level target will be required for planned experimental work. The analysis was performed using a numerical ray tracing procedure that incorporates both random and systematic errors due to slope and surface irregularities. The optimization process varied secondary element size, curvature, and offset angle, and yielded information required for optimum design. As a single secondary element was found impractical, three elements were designed for use at various time of the year. The numerical analysis predicts that typically 70 to 75 percent of the ...
1995-02-01
British Library Electronic Table of Contents (United Kingdom)
We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.
2011-01-01
On and off-axis ECH modulation experiments on RTP
Energy Technology Data Exchange (ETDEWEB)
In a new series of modulated electron cyclotron heating (MECH) on RTP the MECH power was deposited either on-axis or off-axis in plasmas with different values of the plasma current (I{sub p}). Besides confirming all previous MECH results on RTP, the new data can be simulated by assuming a radial profile of the incremental diffusivity ({chi}{sup inc}) that is constant ({chi}{sup inc} < 1 m{sup 2}/s) inside the sawtooth region, makes a sharp step near the inversion radius, and has an offset parabolic profile elsewhere with a value of {chi}{sup inc} {approx} 6 m{sup 2}/s at r/a {approx} 0.6. No significant dependence of {chi}{sup inc} on q{sub a} is observed apart from the position of the transition from low to high {chi}{sup inc}. (author) 5 refs., 4 figs.
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
The polarization characteristics of spontaneous radiation from relativistic electrons moving through helical and planar wiggler fields are evaluated for imperfect beam injection. Maximum coherent gain in free-electron laser systems are seen to occur in optical fields having these polarization characteristics rather than those of the wiggler magnets. Coupling coefficients for an electron beam skewed at an angle to the optical mode are presented.
1995-11-01
International Nuclear Information System (INIS)
This paper describes a semi-empirical calculation of the air-broadened half-widths and the air pressure-induced frequency shifts for the H_2"1"6O isotopologue. This semi-empirical calculation is based on fits of several recent high-quality measurements and theoretical calculations to the first-order terms in the expansion of the complex Robert-Bonamy (CRB) equations, which yields a second- and first-order polynomial function of the differences in the upper- and lower-state vibrational quantum numbers for the half-width and line shift, respectively. The aim of this work was to obtain a complete set of air-broadened half-widths and air pressure-induced frequency shifts for transitions of H_2"1"6O present in the HITRAN database from microwave to the visible in order to supplement the observed and calculated values. For around 700 sets of rotational quantum numbers (J"'K_a"'K_c"'<-J"''K_a"''K_c"''), ...
2005-12-01
International Nuclear Information System (INIS)
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, ...
2008-10-19
Energy Technology Data Exchange (ETDEWEB)
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of the coefficient of ...
2002-06-01
British Library Electronic Table of Contents (United Kingdom)
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
2011-01-01
International Nuclear Information System (INIS)
Cavity ringdown spectroscopy (CRDS) with continuous-wave (cw) laser excitation has added high frequency resolution to the ability of CRDS being used for the absolute quantification of trace-level species present in many chemical processes. Cavity dithering technique has easily resolved the problem of resonant coupling of a cw laser light into a high-finesse cavity. The present study addresses the potential uncertainty involved in such cw-CRDS techniques incorporating the cavity mirror motion, i.e., the doppler frequency shift of a probe light inside the cavity. In the high-resolution spectroscopic work of megahertz-accuracy, even the influence of intracavity doppler effect may become significant.
2001-11-01
Automated bead-positioning system for measuring impedances of R-F cavity modes
Energy Technology Data Exchange (ETDEWEB)
We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.
1993-05-01
Characterization of an add-on multileaf collimator for electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the ...
2008-02-21
Spontaneous radiation from relativistic electrons in a taper undulator. Technical report
The spectrum, angular distribution, polarization and coherence properties of the radiation emitted by relativistic electrons undulating through a quasiperiodic tapered magnetic field are studied. Tapering the wavelength and/or field strength along the undulator's axis has the effect of spreading the spectral line to higher frequencies; interference over this broader spectral range results in a more complex line shape. The angular dependence, on the other hand, is not affected by the amount of taper. The polarization of the radiation in the forward direction is determined by the transverse polarization of the undulator, but the polarization changes off axis. The radiation patterns predicted here are distinct from those of untapered undulators, and their detection is now feasible. They will provide useful diagnostics of electron trajectories and threshold behavior in free-electron-laser oscillators using tapered undulators.
1983-06-01
Spontaneous and stimulated Raman studies of vibrational dephasing in condensed phases
Energy Technology Data Exchange (ETDEWEB)
Vibrational dephasing in condensed phases is studied from both a theoretical and experimental standpoint. A theory is presented which describes the dynamics of motional or exchange processes in weakly perturbed systems. This general formalism, which has been previously used to describe motional narrowing in magnetic resonance, is applied to vibrational spectroscopy. The model treats the case of a high frequency vibration anharmonically coupled to a low-frequency vibration. Intermolecular exchange of low frequency vibrational quanta results in a temperature dependent broadening and frequency shift of the high frequency vibration. Analysis of experimental data by this model yields both the exchange rates and the anharmonic couplings.
1980-05-01
Soft X-ray holography of FIB nanostructured Co/Pt multilayers
International Nuclear Information System (INIS)
Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in contrast to the observations when milling ...
2009-03-22
Macroscopic angular momentum states of Bose-Einstein condensates in toroidal traps
International Nuclear Information System (INIS)
We consider a Bose-Einstein condensate (BEC) of N atoms of repulsive interaction #approx# U_0, in an elliptical trap, axially pierced by a Gaussian-intensity laser beam, forming an effective (quasi-2D) toroidal trap with minimum at radial distance #rho# = #rho#_p. The macroscopic angular momentum states #PSI#_l(#rho#,#theta#) #approx# #sq root#N#PHI#_l(#rho#)e"i"l"#theta# for integer l spread up to #rho# > #rho#_p. The spreading lowers rotational energies, so estimated low metastability barriers can support large l < or approx. l_m_a_x #approx# (NU_0)"1"/"4, < or approx. 10 for typical parameters. The l-dependent density profile module #PHI#_l(#rho#)"2 -#PHI#_0(#rho#)"2 is a signature of BEC rotation. Results are insensitive to off-axis laser displacements #rho#_0, for #rho#_0 #rho#_m_a_x << 1. (author).
Beam-breakup calculations for the Los Alamos free-electron laser (FEL) linac
International Nuclear Information System (INIS)
In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode acts to deflect the beam, and further assumes that this mode does not couple from one accelerating cavity to the next.
Coherently pulsed laser source
Energy Technology Data Exchange (ETDEWEB)
An electronically controllable apparatus is described which modulates a continuous wave laser beam so as to produce an output beam consisting of coherent ''pulses'' that are electronically controllable as to both pulse repetition rate and pulse width. The apparatus includes two acoustic devices positioned so that the laser beam passes through them in sequence, and apparatus or for passing sound waves through the devices to frequency shift the laser radiation as well as to diffract it. Each acoustic device such as generates sound waves containing a group of frequencies which result in spaced pulses. The spreading of a laser beam at which emanates from the first acoustic device is countered by the second acoustic device to produce a collimated, coherently pulsed, laser beam.
1982-06-01
British Library Electronic Table of Contents (United Kingdom)
A series of desilicated ZSM-5 catalysts previously shown to have improved catalytic performance in the MTG (methanol-to-gasoline) reaction [M. Bjorgen, F. Joensen, M.S. Holm, U. Olsbye, K.-P. Lillerud, S. Svelle, Appl. Catal. A 345 (2008) 43] was subjected to thorough examination using FTIR. Clearly, defects represented by internal Si-OH sites are removed upon NaOH treatment. In a parallel manner, free Si-OH sites increase in concentration and the results point to a selective mechanism for formation of mesopores as the framework dissolution preferentially takes place at defective sites in the crystallites. The acid properties of the desilicated materials were investigated by applying CO and collidine (2,4,6-trimethylpyridine) as molecular probes. Monitoring the induced frequency shifts upo...
2009-01-01
Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT
Energy Technology Data Exchange (ETDEWEB)
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose and profiles for reference fields and fields irradiated with ...
2006-02-07
International Nuclear Information System (INIS)
The goal of this work is to present a systematic Monte Carlo validation study on the clinical implementation of the enhanced dynamic wedges (EDWs) into the Pinnacle"3 (Philips Medical Systems, Fitchburg, WI) treatment planning system (TPS) and QA procedures for patient plan verification treated with EDWs. Modeling of EDW beams in the Pinnacle"3 TPS, which employs a collapsed-cone convolution superposition (CCCS) dose model, was based on a combination of measured open-beam data and the 'Golden Segmented Treatment Table' (GSTT) provided by Varian for each photon beam energy. To validate EDW models, dose profiles of 6 and 10 MV photon beams from a Clinac 2100 C/D were measured in virtual water at depths from near-surface to 30 cm for a wide range of field sizes and wedge angles using the Profiler 2 (Sun Nuclear Corporation, Melbourne, FL) diode array system. The EDW output factors (EDWOFs) for square fields from 4 to 20 cm wide were measured in virtual water using a small-volume ...
2009-01-21
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used to measure depth ...
British Library Electronic Table of Contents (United Kingdom)
Abstract Series of typical -type and pseudo--type halogen-bonded complexes BClY and BBrY and hydrogen-bonded complex BHY (B = C2H4, C2H2, and C3H6; Y = F, Cl, and Br) have been investigated using the MP2/aug-cc-pVDZ method. A striking parallelism was found in the geometries, vibrational frequencies, binding energies, and topological properties between BXY and BHY (X = Cl and Br). It has been found that the lengths of the weak bond d(X)/d(H), the frequencies of the weak bond (X)/(H), the frequency shifts (XY)/(HY), the electron densities at the bond critical point of the weak bonds c(X)/c(H), and the electron density changes c(XY)/c(HY) could be used as measures of the strengths of typical -type and pseudo--type halogen/hydrogen bonds. The typical -type and pseudo--type halogen bond and hyd...
2011-01-01
The helical tomotherapy thread effect
International Nuclear Information System (INIS)
Inherent to helical tomotherapy is a dose variation pattern that manifests as a 'ripple' (peak-to-trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering or beam divergence, an analytical posing of the problem as a simple integral predicts minima near a pitch of 1/n where n is an integer. A convolution-superposition dose calculator (TomoTherapy, Inc.) included all the physics needed to explore the ripple magnitude versus pitch and beam width. The results of the dose calculator and some benchmark measurements demonstrate that the ripple has sharp minima near p=0.86(1/n). The 0.86 factor is empirical and caused by a beam junctioning of the off-axis dose profiles which differ from the axial profiles as well as a long scatter tail ...
2005-05-01
The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations
International Nuclear Information System (INIS)
Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose re-buildup, which occurs behind the hip region, becomes more and more obvious for denser ...
2002-07-01
Optimizing an analytical dose calculation algorithm for fast 2D calculations
International Nuclear Information System (INIS)
Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the dose calculation model is implemented in Visual Basic 6.0, which decreases the ...
International Nuclear Information System (INIS)
For the Convolution, Superposition and Monte Carlo methods, energy spectrum data is an essential parameter. Especially, by using Monte Carlo method, if the adequate properties of electrons are set, complex energy spectrum data can be calculated by simple input. However, adjustment of the property of electrons incident on the target of linear accelerator is time-consuming procedure. To cover the difference of many accelerators, it is important how we obtain accurate energy spectrum by simple methods. Especially, the total accuracy of dose calculation depends on the agreement of measured and calculated percentage depth dose (PDD) and off-axis ratio (OAR). Thus, a simple method for the determination of the simulation parameters was considered. To reduce the adjustment procedure, we selected values of important three parameters, which were the mean energy of the input electron beam, the energy distribution of the input electron beam and the radial distribution of the ...
2005-06-01
Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system
International Nuclear Information System (INIS)
In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To speed up the calculations, a number of calculation techniques were ...
2000-04-01
Dismembered Archean ophiolite in the SE. Wind River Mountains, Wyoming
Energy Technology Data Exchange (ETDEWEB)
Ophiolitic rocks occur as wall rocks of the 2.7 Ga Louis Lake batholith near Atlantic City, Wyoming. All of the Archean rocks are strongly deformed and metamorphosed to a greenschist and amphibolite facies, but relict structures and textures are commonly preserved. These include the following, from west to east: (1) metadiabase with rare coarse-grained metagabbro; (2) ultramafic rocks and metagabbro; (3) amphibolite, locally pillowed, overlain(.) by pelitic schist, banded iron formation, and quartzite; and (4) pillow lavas, massive sills or flows, and minor metasedimentary rocks. Slice 1 locally contains parallel dike margins and rare metagabbro screens; these features suggest that it may represent a sheeted dike complex. Slice 2 locally contains ultramafic rocks having relict cumulus textures and igneous layering, corresponding to the cumulus portion of an ophiolite. The pillow lavas of slice 4 and possibly slice 3 are interpreted as comprising the extrusive portion of the ophiolite. ...
1985-01-01
The spectral dependences of absorption photoinduced in a pure bismuth titanium oxide crystal by 532-nm laser pulses are studied. It is shown that optical absorption in the crystal in the range from 492 to 840 nm increases with increasing exposure. The photoinduced absorption relaxes in the dark for more than 60 hours. A model of photoinduced absorption is proposed which assumes the population of two trap centres with the normal energy distribution law for the concentrations of electrons photoexcited from donors to the conduction band. This model well describes the spectral dependences of photoinduced absorption by using the average ionisation energies of the traps E{sub 1} = 1.60 eV and E{sub 2} = 2.57 eV. The model is used to estimate the increase in the photorefractive sensitivity of a bismuth titanium oxide crystal in the near IR region, which was earlier observed after exposing the crystal to visible radiation. It is predicted that the speed of response of dynamic ...
2007-11-30
Holography of a Composite Inflaton
We study the time evolution of a brane construction that is holographically dual to a strongly coupled gauge theory that dynamically breaks a global symmetry through the generation of an effective composite Higgs vev. The D3/D7 system with a background magnetic field or non-trivial gauge coupling (dilaton) profile displays the symmetry breaking. We study motion of the D7 brane in the background of the D3 branes. For small field inflation in the field theory the effective Higgs vev rolls from zero to the true vacuum value. We study what phenomenological dilaton profile generates the slow rolling needed, hence learning how the strongly coupled gauge theory's coupling must run. We note that evolution of our configuration in the holographic direction, representing the phyiscs of the strong interactions, can provide additional slowing of the roll time. Inflation seems to be favoured if the coupling changes by only a small amount or very gently. We speculate on how such a scenario could be ...
2010-01-01
Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser
International Nuclear Information System (INIS)
We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. We have fabricated and tested various multilayer mirrors for ...
2008-04-01
A Topology-Changing Phase Transition and the Dynamics of Flavour
In studying the dynamics of large N_c SU(N_c) gauge theory with fundamental quark flavours in the quenched approximation, we observe a novel phase transition at finite temperature. A quark condensate forms at finite quark mass, and the value of the condensate varies smoothly with the quark mass for generic region in parameter space. At a particular value of the quark mass, there is a finite discontinuity in the condensate's vacuum expectation value, corresponding to a first order phase transition. We study this using holography, the string dual being the geometry of N_c D3--branes at finite temperature, AdS_5-Schwarzschild times S^5, probed by a D7-brane. The D7-brane has topology R^4 times S^3 times S^1, and allowed solutions correspond to either the S^3 or the S^1 shrinking away in the interior of the geometry. The phase transition represents a jump between branches of solutions having these two distinct D-brane topologies and the transition also appears in the ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the incidents. The results ...
2007-07-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
