Radiation hazards from medical applications
International Nuclear Information System (INIS)
An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).
1980-05-31
Development of new radiopharmaceuticals
International Nuclear Information System (INIS)
The possibilities to design and prepare better and more organ-specific radiopharmaceuticals for diagnostic nuclear medicine has increased dramatically in the recent past with a deeper understanding of the relationships between chemical structure and biological activity. Whereas most of the research is performed in well-funded laboratories of industrialized countries, there are several developing countries with adequate resources and expertise as to undertake fruitful research in the field of radiopharmacy. With the aim of promoting advanced research in radiopharmacy by developing new radiodiagnostics agents, in particular, hepatobiliary imaging agents labelled with "9"9"mTc, and to facilitate exchange of information, the IAEA has established in 1983 the present Research Co-ordination Programme (CRP) with a duration of five years. The report includes detailed results obtained by all participants as well as novel preparation procedures for some of the newest and more ...
1988-09-12
Analyses of superficial and depth doses in intraoral radiology
Energy Technology Data Exchange (ETDEWEB)
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The ...
2006-07-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.