In-vitro experiments using 203Pb were performed to identify the lead binding components in human peripheral blood. The distribution of lead in plasma, in the red cell membrane, and within the red cell...Full Text Available
Theoretical analysis of the electric field bifurcation is made for the LHD plasma. For given shapes of plasma profiles, a region of bifurcation is obtained in a space of the plasma parameters. In this region of plasma parameters, the electric field domain interface is predicted to appear in the plasma column. The reduction of turbulent transport is expected to occur in the vicinity of the interface, inducing a internal transport barrier. Within this simple model, the plasma with internal barriers is predicted to be realized for the parameters of T{sub e}(0) {approx} 2 keV and n(0) {approx_equal} 10{sup 18} m{sup -3}. (author)
BACKGROUND: Since the identification of xenotropic murine leukemia virus-related virus (XMRV) in prostate cancer patients in 2006 and in chronic fatigue syndrome patients in 2009, conflicting findings have been reported regarding its etiologic role in human diseases and prevalence in general populations. In this study, we screened both plasma and peripheral blood mononuclear cells (PBMNCs) collected in Africa from blood donors and human immunodeficiency virus Type 1 (HIV-1)-infected individuals to gain evidence of XMRV infection in this geographic region. STUDY DESIGN AND METHODS: A total of 199 plasma samples, 19 PBMNC samples, and 50 culture supernatants from PBMNCs of blood donors from Cameroon found to be infected with HIV-1 and HIV-1 patients from Uganda were screened for XMRV infecti...
In this article, the results of low-current gas-discharge plasma generator investigations carried out by a group of scientists from the Kazan' Aviation Institute are presented. When considered necessary, the results are compared with the data obtained by other authors. The basic configurations and theoretical calculation peculiarities of plasma generators are described. The electrical, thermal and energy characteristics of discharges in gas flows, as well as summarised empirical formulae and experimental data necessary for calculations and design of plasma devices are presented. (author)
Based on the nonlinear dispersion relation of electromagnetic wave in relativistic plasma, the nonlinear controlling equation for linearly polarized mode is obtained using Karpman's method. The modulation instability of intense laser pulse propagating through relativistic plasma is analyzed and the modulation instability growth rate as a function of perturbation wave number for laser beam propagating through relativistic plasma is given. (authors)
The spontaneous evolution from ultracold Rydberg atoms to plasma is investigated in a caesium MOT by using the method of field ionization. The plasma transferred from atoms in different Rydberg states (n=22-32) are obtained experimentally. Dependence of the threshold time of evolving to plasma and the threshold number of initial Rydberg atoms on the principal quantum number of initial Rydberg states is studied. The experimental results are in agreement with hot-cold Rydberg-Rydberg atom collision ionization theory. (authors)
It is known that a high-power laser propagating through an underdense plasma can acquire a minimum spot size due to relativistic self-focusing. Beyond the focus, the nonlinear refraction starts weakening, and the spot size of the laser increases, showing periodic self-focusing/ defocusing behavior with the distance of propagation. To overcome the defocusing, we propose the introduction of a localized upward plasma density ramp. In the presence of an upward ramp of plasma density, the laser beam obtains a minimum spot size and maintains it with only a mild ripple. For suitable parameters of the laser and the plasma, we have deduced conditions for the self-focusing. This kind of plasma density ramp may be observed in a gas-jet plasma experiment and resembles a plasma lens.
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ...
Plasma confinement by permanent magnets has been studied. An analytic formula for the field of a single bar magnet has been obtained. Generalization to various configurations of multidipole fields has also been found. Any two-dimensional field may now be completely described by a simple function of complex variables in closed form. Vector potential has also been obtained by integrating over a prescribed Riemann surface. The confinement of plasma by multidipole fields then becomes obvious through conservation principles.
The UTST (University of Tokyo Spherical Tokamak) device was constructed for the purpose of exploring the formation of ultra-high beta ST (Spherical Tokamak) plasma using the double null plasma merging method. When two plasmas merge together to form a single plasma, magnetic field lines reconnect, and the magnetic field energy is converted to the plasma kinetic energy, increasing the plasma beta. The merging start-up has been demonstrated in the TS-3/4, START and MAST devices using coils inside the vacuum vessel and TS-3 plasmaobtained 50% beta. In order to demonstrate the start-up in a more reactor relevant situation, UTST has all poloidal field coils outside the vacuum vessel. The first plasma experiment on the UTST was performed from December, 2007. In the result, the plasma ...
We investigated the presence of XMRV in a cohort of Quebec patients with chronic fatigue syndrome (CFS). DNA was purified from activated peripheral blood mononuclear cells (PBMCs) and PCR was used to detect XMRV gag and env in 72 patients. Anti-XMRV antibodies were searched in sera of 62 patients by Western blot analysis. Attempts to detect XMRV antigens was made, using immunofluorescence with Gag anti-p30 antiserum on activated PBMC from 50 patients. Plasma viremia was measured by RT-PCR on 9 subjects. Finally, detection of infectious virus in 113 CFS subjects was made by co-culture of PHA+IL-2 activated PBMC with human LNCaP carcinoma cells, and by infecting the same susceptible cells with plasma, using a reverse transcriptase (RT) assay as a readout in both experiments. No detection of ...
A study is made into microhardness and structure of coatings on various system steels (37G2S, 25Kh5M, R6M5), obtained by ion nitriding in a low pressure (10"-"1 Pa) arc discharge plasma. A comparison of properties is accomplished for steels nitrided in an arc gas discharge and in a furnace. It is stated that ion-plasma nitriding in an arc gas plasma generator is an efficient method of alloy steels hardening which allows changing the structure and increasing the hardness of a surface layer up to rather great depth
This paper presents the first results of a study of plasma nitriding in various regions of a d.c. glow discharge, i.e. on the cathode, on the anode, and on a substrate isolated from the cathode and anode (at plasma potential). The results obtained reveal differences in the growth kinetics and surface morphology of the nitriding layers, depending on the region where the nitriding process took place. The aim of this work was to study the role of low temperature plasma in the plasma nitriding process. The processes were carried out in an apparatus for plasma treatment with a hot anode. (orig.)
The measurement of electron densities using interferometry and refraction measurements in plasmas with cross-sections where the electron density contours are concentric ellipses is examined. Transforms are found for both interferometrically deduced optical path-length differences and refraction angle data obtained from elliptical cross-section plasmas. The transformed data can be inverted to give electron densities using standard techniques developed for circular cross-section plasmas. Refraction of light in elliptical cross-section plasmas is examined using numerical ray tracing.
The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.
A detailed study has been performed for estimating the orbital energies, positions and shifts of the Lyman lines of C5+, Al12+ and Ar17+ under strongly coupled plasma with a view to understand such line positions and shifts obtained in laser produced plasma experiments. The effect of strongly coupled plasma has been treated within the Ion Sphere (IS) model. Both non-relativistic and relativistic methods have been used for estimating the spectral properties. Theoretical estimates with IS model of the plasma are in conformity with the results of laser plasma experiments on these highly stripped ions. The experimental data for the systems have also been compared with the theoretical estimates using Debye screening model of the plasma with spatial confinements which gives additional restrictions to the wave functions at finite boundaries.
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those ...
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those ...
This study investigated the effects of electromagnetic fields on enzymes involved in purine metabolism in human peripheral blood mononuclear cells in vitro. Cells were obtained from 20 volunteers. We...Full Text Available
In-vitro experiments using "2"0"3Pb were performed to identify the lead binding components in human peripheral blood. The distribution of lead in plasma, in the red cell membrane, and within the red cell was also investigated. Studies of the distribution of "2"0"3Pb in the whole blood showed that at a lead concentration of 2.45 #mu#mol/l (50 #mu#g/100 ml) about 94% of lead had been incorporated by the erythrocytes and 6% remained in the plasma. After extraction of lipid by a methanol/chloroform mixture, about 75% of the lead was found to be associated with the protein fraction. The lipid contained about 21% of the "2"0"3Pb, the remainder being in the aqueous plasma. SDS polyacrylamide gel electrophoresis of blood plasma showed that almost 90% of the "2"0"3Pb was present in the albumin fraction; the remainder was likely to be associated with high molecular weight globulins. Several ...
To analyze the enhancement patterns and morphology of peripheral cholangiocar-cinomas (CCs), as seen on three-phase helical CT. Three-phase helical CT scans of 25 cases of 24 patients with pathologically-proven CCs were retrospectively reviewed. After intravenous administration of contrast media, scans of the hepatic arterial phase (HAP) were obtained at 30 seconds, of the portal venous phase (PVP) at 70 seconds, and of the delayed phase (DP) at 3 minutes. Linear, dense, marginal enhancement was seen in 17 CCs (68%), mainly on HAP images (64%) while thick, band-like, peripheral enhancement was seen in 18 (72%), on either PVP (52%) or DP (44%). Internal enhancement was observed in 23 CCs (92%) on PVP (68%) and/or DP (88%), and 19 CCs (76%) among them showed incomplete enhancement of stippled and/or septated patterns. Most (76%) were seen throughout all three phases to be hypoattenuating, as compared to the surrounding ...
The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.
A two-beam spectroscopy (TBS) system is evaluated theoretically and experimentally. This new spectroscopic technique uses correlations between components of emitted light separated by a small difference in angle of propagation. It is thus a non-perturbing plasma diagnostic which is shown to provide local (as opposed to line-of-sight averaged) information about fluctuations in the density of light sources within a plasma - information not obtainable by the usual spectroscopic methods. The present design is an improvement on earlier systems proposed in a thesis by Rostler.
This study was the analyse the relationship between properties of ion nitrided Fe sintered material and parameters of plasma nitriding process. Pure fe sintered materials (relative density : 92%) were fabricated by hot-pressing and nitrided under pulsed DC plasma for 4 hours. The large number of parameters in plasma diffusion treatment allows close control of the process so that surface layers with defined microstructures and properties can be obtained. The number of micropores in nitriding layer can be reduced in pulsed DC plasma by reducing the plasma power and by varying the gas mixture. The phase constitution of compound layer of nitrided Fe sintered material were influenced by gas mixture (N{sub 2} : H{sub 2}) and pulsed ratio (pulse on/off time ratio)
This study was the analyse the relationship between properties of ion nitrided Fe sintered material and parameters of plasma nitriding process. Pure fe sintered materials (relative density : 92%) were fabricated by hot-pressing and nitrided under pulsed DC plasma for 4 hours. The large number of parameters in plasma diffusion treatment allows close control of the process so that surface layers with defined microstructures and properties can be obtained. The number of micropores in nitriding layer can be reduced in pulsed DC plasma by reducing the plasma power and by varying the gas mixture. The phase constitution of compound layer of nitrided Fe sintered material were influenced by gas mixture (N_2 : H_2) and pulsed ratio (pulse on/off time ratio).
An estimation method of plasma density based on surface plasmons theory for surface-wave plasmas is proposed. The number of standing-wave is obtained directly from the discharge image, and the propagation constant is calculated with the trim size of the apparatus in this methods, then plasma density can be determined with the value of 9.1 x 1017 m-3. Plasma density is measured using a Langmuir probe, the value is 8.1 x 1017 m-3 which is very close to the predicted value of surface plasmons theory. Numerical simulation is used to check the number of standing-wave by the finite-difference time-domain (FDTD) method also. All results are compatible both of theoretical analysis and experimental measurement. (authors)
In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is employed in the ...
This paper reports on the electron current to a Langmuir probe in a moving high-pressure plasma. The plasma is an atmospheric-pressure propane flame, and the probe's speed relative to the plasma is varied from 10 to 30 ms"-"1. The current is linearly dependent on the speed and appears to be comprised of two components - one driven by diffusion and the other by convection. A model is devised which can be used to measure the electron density. By comparing the density computed from this model to that measured from the ion current, it has been possible to measure the electron mobility in the flame gases. The value obtained here is in good agreement with theoretical calculations found in the literature.
The sheath plasma characteristics changing with the negative bias applied to the substrate during electron cyclotron resonance plasma nitriding are studied. The sheath characteristics obtained by a Langmuir single probe and an ion energy analyzer show that when the negative bias applied to the substrate is increasing, the most probable energy of ions in the sheath and the full width of half maximum of ions energy distribution increase, the thickness of the sheath also increases, whereas the saturation current of ion decreases. It has been found from the optical emission spectrum that there are strong lines of N_2 and N_2"+. Based on the experiment results the mechanism of plasma nitriding is discussed
The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)
Iron deficiency (ID) is associated with increased levels of norepinephrine (NE) in plasma and urine. They investigated the effect of 5-7 days exposure to three different environmental temperatures (10/sup 0/C, 24/sup 0/C, 30/sup 0/C) on urinary catecholamine levels to test the hypothesis that increased thermogenic activity is causal to this increased excretion in iron deficiency. Catecholamines were analyzed from acidified urine by HPLC-EC. The mean Hb in ID animals was 3.1 +/- .5 versus controls of 12.8 +/- 9. These data demonstrate that contrary to previous reports NE excretion is not normalized at a thermoneutral temperature and suggests a basic abnormality in peripheral SNS activity and NE metabolism in iron deficiency that is independent of environmental drive from thermogenesis.
As for surface treatment of steel, the ion nitriding method has a lot of advantages and is practically used, while the plasma nitriding is known as a method which is faster in nitriding than the ion nitriding method. However, there are few reports and many unclear points on the plasma nitriding method. In this study, the plasma nitriding of pure iron and SUS304 is conducted using r.f. nitrogen plasma glow discharge to examine composition of the nitrided layers, microstructures, nitriding rate, etc. Moreover, by exposing the specimen once nitrided to H2 plasma, a phenomenon that nitrogen comes out of the specimen surface is examined. It is found from the result that the nitrided layer is divided into a compound layer and a diffusion layer in order from the surface, that in case of pure iron, the compound layer grows predominantly at a low temperature, and the diffusion layer grows ...
We have studied the features of formation and the possible stationary structures of a self-consistent magnetic field in a relativistic collisionless plasma, which are characteristic of a simple geometry of the Weibel instability that is well known in the nonrelativistic case. The universal condition is established, the growth rate is determined, and the criteria of saturation of the Weibel instability are analyzed for a broad class of anisotropic particle distribution functions (for definiteness, in application to an electron-positron plasma). A nonlinear equation of the Grad-Shafranov type describing the potential current structures is derived and its solutions are analytically studied. Special attention is paid to spatially harmonic, nonlinear current configurations with parameters determined by the properties of the initial homogeneous plasma subject to the Weibel instability. It is demonstrated that the magnetic field ...
In this paper we study theoretically a pulsed corona discharge plasma in air at atmospheric pressure. A self consistent one-dimensional model, using a flux-corrected transport numerical scheme, is presented to achieve it. The charged particle kinetics in this model are described by one-dimensional continuity equations coupled with Poisson's equations. The spatio-temporal local field, charge density variations and the velocity profile of an ionizing front are calculated to describe the dynamical behavior of corona discharge plasmas. The simulation results of a wire-in-cylinder corona discharge plasma explain the physical mechanisms of discharge processes. These results may also be apply to obtain the optimizing parameters for designing the plasma reactor.
The present conference discusses plasma-assisted surface coating/modification processes, the applications to date of ion nitriding, the effects of nitrogen on metal surfaces, ion nitriding mechanisms in Cr, Al and Cr + Al-containing 1040 steel, ion nitriding of Al and its alloys, life enhancement for forging dies, novel anode plasma nitriding developments, and a comparative study of the pulsed and dc ion-nitriding behavior in specimens with blind holes. Also discussed are the influence of heating method on ion nitriding, surface hardening of marage steels by ion nitriding without core hardness reduction, plasma nitriding of nodular cast iron sput gears, NbN composites for superconductors, the carburization of tungsten in a glow discharge methane plasma, economic considerations concerning plasma nitriding, and the corrosion properties obtained by ion nitriding.
The combined process of low temperature plasma nitriding and TiN film deposition was realized on the plasma-assisted vacuum arc plating set. The process of plasma nitriding can be done below 200 degree C. The low temperature plasma nitriding and TiN film deposition was realized on the same device. By the SEM analysis of the plating structure, low hardness grads from the substrate to the film was obtained, and it was found that the mixed nitride plating formed at the interface between the substrate and the film. The quantitative measurement of substrate-film adherence showed that the adherence was improved notably by using the process. The adherence between film and substrate can reach to 59.6 MPa without the bias voltage supplying
The thermo-chemical treatments of steels with plasma is normally carried out in low-pressure ionized gaseous atmospheres. Among the treatments used most often are: nitruration, carburization and boronized. A plasma can also generate at atmospheric pressure. One way to produce it is with an electrochemical cell that works at a relatively high inter-electrode voltage and under conditions of heavy gas generation. This type of plasma is known as electrolytic plasma. This work studies the feasibility of using electrolytic plasma for the surface processing of steels. Two processes were selected: boronized and nitruration., for the hardening of two types of steel: one with low carbon (1020) and one with low alloy (4140). In the case of the nitruration, the 1020 steel was first aluminized. The electrolytes were aqueous solutions of borax for the boronizing and urea for the nitruration. The ...
This report is devoted to the investigation of the influence of electron collisions and radial non-uniformity of plasma density on phase characteristics, spatial attenuation and wave field structure of slow symmetric electromagnetic waves that propagate along cylindrical waveguide structure. It has been shown that collision rate and radial non-uniformity of plasma density for various parameters of waveguide structure and dielectric affect essentially on the wave characteristics and consequently, on the parameters of gas discharge that is sustained by this wave. The results obtained are of large importance for the construction of the theory of gas discharges that are sustained by the surface electromagnetic waves.
With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)
Quark Gluon Plasma transport coefficients for heavy quarks and quark-antiquark pairs are computed through an extension of the results obtained for a hot QED plasma by describing the heavy-quark propagation in the eikonal approximation and by weighting the gauge field configurations with the Hard Thermal Loop effective action. It is shown that such a model allows to correctly reproduce, at leading logarithmic accuracy, the results obtained by other independent approaches. The results are then inserted into a relativistic Langevin equation allowing to follow the evolution of the heavy-quark momentum spectra. Our numerical findings are also compared with the ones obtained in a strongly-coupled scenario, namely with the transport coefficients predicted (though with some limitations and ambiguities) by the AdS/CFT correspondence.
Nitriding of aluminium 2011 using a radio frequency plasma at higher power levels (500 and 700 W) and lower substrate temperature (500 deg. C) resulted in higher AlN/Al_2O_3 ratios than obtained at 100 W and 575 deg. C. AlN/Al_2O_3 ratios derived from X-ray photoelectron spectroscopic analysis (and corroborated by heavy ion elastic recoil time of flight spectrometry) for treatments preformed at 100 (575 deg. C), 500 (500 deg. C) and 700 W (500 deg. C) were 1.0, 1.5 and 3.3, respectively. Scanning electron microscopy revealed that plasma nitrided surfaces obtained at higher power levels exhibited much finer nodular morphology than obtained at 100 W.
Aluminium nitride (AlN) is a very interesting ceramic because of its combination of properties such as high thermal stability, high hardness and an unusual combination of high thermal and low electrical conductivity. But it is very difficulty to obtain an AlN layer on the aluminium substrates by thermochemical nitriding process. Since a thin film of aluminium oxide existing on the surface of every aluminium substrate prevents the nitrogen atoms from diffusing into the aluminium lattice. However, it is possible to sputter the oxide film away from the aluminium surface in a glow discharge with the use of plasma nitriding technique and to allow the formation of AlN layer on the aluminium bulk. In the present work specimen of aluminium Al 99.5 has been plasma nitrided in a modified plasma nitriding unit, in which a diffusion pump was used to obtain an especially low partial pressure of ...
We study the uniqueness of solutions of a semilinear elliptic problem obtained from an inverse formulation when the nonlinear terms of the equation are prescribed in a general class of real functions. The inverse problem arises in the modeling of the magnetic confinement of a plasma in a Stellarator device. The uniqueness proof relies on an L"#infinity# -estimate on the solution of an auxiliary nonlocal problem formulated in terms of the relative rearrangement of a datum with respect to the solution.
ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available
The use of cathode ray irradiated arterial allografts on the reconstruction of small peripheral arteries is described. The fate of irradiated arterial allografts implanted subcutaneously in rats was compared histologically with that of allografts which were fresh, frozen or stored in 70% alcohol. Follow-up studies were made of 10 dogs in which irradiated arterial allografts had been implanted in the femoral artery to be evaluated; long term patency by arteriography, gross and histologic changes of the implanted allografts, and the luminal surface of the implanted allografts by scanning electron microscopic studies. For the purpose of antigenic studies, extracts of canine arteries which had been irradiated, frozen or stored in 70% alcohol, were prepared and tested by the following immunological methods: precipitation, Ouchterlony gel diffusion, and passive cutaneous anaphylaxis. From the results obtained in these experiments, it was concluded ...
In this work it is made a study of the structure and electric properties of chlorate polyethylene (PE-CI) with double and simple bonds obtained by continuous plasma with resistive coupling to 13.5 MHz. The synthesis conditions are power between 10 and 14 W and pressure of (6-7) x 10{sup -2} Torr. The synthesized PE-Cl in that way is soluble in acetone what indicates that probably is formed of short chains and not it shows the generalized inter crossing that is presented in some syntheses by plasma and that it can degrade the electric properties of these polymers. The IR and XPS analysis show the vibration of the C-C, C=C and C-CI bonds. The morphology of the polymer after being dissolved shows a compact and flat configuration. The electric conductivity has an approximately lineal behavior in an interval of 35 to 90% of relative humidity. (Author)
We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)
This paper announces the availability of the first international standard for anti-double-stranded DNA (anti-dsDNA). The material, coded Wo/80, was obtained after recalcification of plasma taken from...Full Text Available
Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).
A two-temperature, axi-symmetric, chemical non-equilibrium model has been developed for an oxygen-plasma cutting torch in two dimensions to obtain distributions of different plasma quantities inside the torch. Apart from mass, momentum and potential conservation equations, separate energy balance equations are considered for electrons and heavy particles. The ?-? model has been used to account for turbulence. Non-equilibrium properties required for fluid dynamic simulations are obtained from a non-equilibrium property code that includes chemical non-equilibrium. The results show distributions of temperature, velocity, pressure, potential, current density and different species densities inside the plasma torch for an arc current of 200 A. Plasma pressure inside the torch varies from several atmospheres to near-atmospheric pressure. It has been observed that the ...
Etching of SiO_2 rods has been obtained with a dc torch with argon as the process gas in an air environment at atmospheric pressure; the high temperature of the plasma jet causes vaporization of the exposed area. The apparatus and torch operative parameters have been set up to obtain a depth etch rate of up to 0.6 mm min"-"1 corresponding to 0.826 g min"-"1. An enthalpy probe has been employed to monitor the plasma conditions before the thermal plasma etching process and from the experimental etch rate a surface rod temperature of T_s_u_r = 2057 K has been derived. Etching has been obtained with uniformity over the entire exposed area with peak to peak differences below 1%. The plasma to rod heat transfer has been simulated using a commercial CFD code Fluent (copyright). The model consists of a non-steady two-dimensional simulation for a ...
Tokamaks with sufficiently strong supplementary heating develop non-Maxwellian electron velocity distributions. Because the absorption of electron cyclotron power is proportional to #nabla#_Vf, even small deviations from a Maxwellian distribution can significantly affect power deposition. Following an approach used to study microinstabilities in a plasma with an arbitrary, numerically specified, electron distribution, we have developed a computational module to study electron cyclotron power deposition in plasmas that have distributions motivated by those in actual tokamaks. Also, we compare the deposition results obtained using an energy balance approach with those obtained using a Taylor expansion of the dielectric tensor. We illustrate the limitations of the latter approach.
Peripheral primitive neuroectodermal tumors (peripheral PNETs) are rare in the abdomen. We report the imaging findings of four peripheral PNETs arising in the abdomen. Three were ill-demarcated tumors and one was a well-demarcated tumor, with extensive local invasion and lymph node metastasis in two cases, respectively. The tumors are of inhomogeneous attenuation and heterogeneous enhancement after intravenous administration of contrast materials. Although their imaging manifestations cannot distinguish them from other sarcomas, recognition of these imaging features may be helpful in suggesting the possibility of peripheral PNETs in some cases.
Suspension direct current plasma spraying allows achieving finely structured coatings whose thickness is between few tens and few hundreds of micrometres. Drops (200-300 ?m in diameter) or liquid jets are mechanically injected in the plasma jet. With radial injection they are rapidly (a few ?s) fragmented into droplets (a few ?m in diameter). The latter are vaporized (in a few ?s) and the solid particles contained in suspension droplets are accelerated and melted by the plasma jet. As in conventional plasma spraying (CPS), much smaller splats (with diameters between 0.2 and 3 ?m and thicknesses between 30 and 200 nm) are arranged in layers up to form the coating. The low inertia of particles requires spray distances between 40 and 60 mm which induces plasma heat fluxes up to 22 MW m-2 participating in coating densification. Even more than in CPS, the plasma jet ...
To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 ...
We have obtained convincing evidence for localization of the optical electron on a single-ring fragment of a chelated bipyridine-like'' ligand (ie., pyridylpyrazine or 4-Methyl-bipyridine). In addition we have completed studies of Ru(bipyrazine){sub 3}{sup 2+} in aqueous sulfuric acid (0--98% by weight) and find clear evidence for sequential addition of six-protons to the six peripheral nitrogen atoms. Studies of zeolite-entrapped complexes are continuing and a series of homo- and heteroleptic complexes have been prepared and characterized. Finally, the synthesis of zeolite-entrapped metallophthalocyanines has now been developed and the copper and cobalt analogues synthesized. The characterization of these materials is now in progress.
Mycoplasma ovipneumoniae is associated with chronic non-progressive pneumonia of sheep and goats. As with many other mycoplasmas involved in animal diseases, protective immune responses have not been achieved with vaccines, even though antibody responses can be obtained. This study focuses on characterizing the interaction of M. ovipneumoniae with ovine PBMC using carboxy-fluorescein-succinimidyl-ester (CFSE) loading and flow cytometry to measure lymphoid cell division. M. ovipneumoniae induced a strong in vitro polyclonal suppression of CD4^+, CD8^+, and B blood lymphocyte subsets. The suppressive activity could be destroyed by heating to 60^oC, and partially impaired by formalin and binary ethyleneimine treatment that abolished its viability. The activity resided on the surface-exposed m...
The relationship between plasma testosterone levels and locomotor activity in wild-caught sexually mature male meadow voles (Microtus pennsylvanicus) was assessed in the laboratory. Several aspects of locomotor activity were monitored for 1 h on two consecutive days using the automated Digiscan activity monitoring system. Plasma testosterone levels were determined immediately following the second day of activity monitoring. Significant Pearson correlations were obtained between plasma testosterone levels and total distance traveled [r(10) = 0.55, p < 0.05] and amount of time spent in movement [r(10) - 0.55, p < 0.05] on the second day. The wild voles showed a reduction in activity levels from the first to the second day of activity monitoring, which is indicative of habituation to a novel environment. This study provides direct evidence for a significant correlation between laboratory measures of ...
The usually low wear resistance of titanium materials can be increased by the thermochemical surface treatment nitriding. In result of comparative investigations of gas and plasma nitriding it will be shown that it is possible to obtain a specific variation of the properties in the highly stressed case by means of these both technologies on example of the ({alpha}+{beta}) alloy Ti-6Al-4V. Gas and plasma nitriding was carried out in the temperature range from 650 to 800 C over 4 to 48 h in different gas atmospheres, i.e. 100% NH{sub 3} (gas), 100% N{sub 2} (gas and plasma), 20% H{sub 2} + 80% N{sub 2} and 20% Ar + 20% H{sub 2} (plasma). The temperature range was fixed in the middle of ({alpha}+{beta}) region, because the core properties are influenced negative in the field of {beta}-transustemperature. The relations between the applied nitriding technologies, the layer structure ...
The usually low wear resistance of titanium materials can be increased by the thermochemical surface treatment nitriding. In result of comparative investigations of gas and plasma nitriding it will be shown that it is possible to obtain a specific variation of the properties in the highly stressed case by means of these both technologies on example of the (#alpha#+#beta#) alloy Ti-6Al-4V. Gas and plasma nitriding was carried out in the temperature range from 650 to 800 C over 4 to 48 h in different gas atmospheres, i.e. 100% NH_3 (gas), 100% N_2 (gas and plasma), 20% H_2 + 80% N_2 and 20% Ar + 20% H_2 (plasma). The temperature range was fixed in the middle of (#alpha#+#beta#) region, because the core properties are influenced negative in the field of #beta#-transustemperature. The relations between the applied nitriding technologies, the layer structure (chemical, phases, ...
A dense and supersaturated nitrogen layer with higher conductivity is obtained on the surface of austenitic stainless steel 304L by the low temperature plasma nitriding. The effect of plasma nitriding on the corrosion behavior and interfacial contact resistance (ICR) for the austenitic stainless steel 304L was investigated in 0.05M H{sub 2}SO{sub 4}+2ppm F{sup -} simulating proton exchange membrane fuel cell (PEMFC) environment using electrochemical and electric resistance measurements. The experiment results show that the stable passive film is formed after the potentiostatic polarization at the specified anodic or cathodic potentials under PEMFC operation condition, and the plasma nitriding improves slightly the corrosion resistance and decreases markedly the ICR of 304L. The ICR of the plasma nitrided 304L increases after the potentiostatic polarizations for 4h, and lower than ...
With the aim of optimizing the nitriding process, experimental studies of the plasma nitriding of four selected steels were carried out, using a d.c. glow discharge. The process parameters were varied systematically. By means of transmission and scanning electron microscopy and X-ray diffraction, the microstructures, including the thicknesses of the compound zones and the diffusion zones of the nitrided steels, were obtained. Using cross-sectional samples and a micro-Vickers indenter, hardness depth profiles were also obtained. From the time and temperature dependences of the hardness profiles, effective diffusion constants and corresponding activation enthalpies were obtained. Furthermore, in an attempt to shed some light on the atomistic nitriding mechanisms, the glow discharges were studied by measuring energy spectra of the energetic ions hitting the cathode (the steel test specimens). It was shown ...
The method of production of xAl{sub 2}O{sub 3}-yTiO{sub 2} compositions provides for the depth distribution of coating components and specifies its mechanical properties. In case of the composition obtained by cladding, titanium is mainly concentrated at the substrate. In case of mechanical mixture or composition obtained by sintering the oxides, the depth distribution of coating components is random.
The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior ...
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
The Joint European Torus (JET) fusion machine is the only device capable of operation with tritium (as fuel) and Be (as plasma facing component), what makes it best suited to study ITER relevant issues. A large variety of activities are performed within the JET Fusion Technology Task Force. In this paper, some topics such as erosion/deposition and material transport, flakes characterization and detritiation techniques are highlighted. Recent results obtained using a pumping cryo-panel and on plasma facing component characterisation are given. Finally, issues that will be addressed in the forthcoming JET work-programme are presented, such as a beryllium main wall for JET and in-situ laser detritiation. (authors)
The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)
Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alpha particles may expel the alpha particles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)
Studies on the kinetics of the distribution of lead-203 in body fluids have been carried out in vitro, and in animal studies using beagle dogs. In vitro, the distribution of carrier free lead-203 between plasma and cells of canine blood at 37"0C was measured after the addition of isotope. In animal studies, activity in plasma was measured for about 150 hours, and activity in blood cells, urine and feces measured for about 400 hours after exposure to lead-203. Linear compartmental models for distribution of the isotope are presented for both in vitro and in vivo experimental systems. The models contain compartments for both untransformed lead, for isotope added in saline or citric acid, and transformed lead, as obtained by lead-203 incubation in plasma.
Plasma polymerization of aniline is carried out in a radiofrequency plasma reactor and the effect of polymerization time is examined in the structural, optical and optoelectronic properties of deposited films. Conjugated structures of polyaniline like films are obtained with unique and broad optical absorption band in the ultraviolet and entire visible region. The width of the absorption band increases and hence the optical band gap decreases with polymerization time. The optical constants are extracted by Swanepoel method and the optical dispersion parameters are determined by employing the Wemple-DiDomenico single oscillator model. The films exhibit similar thermal stability in air and argon atmosphere in the region of interest for optoelectronic applications. The photoluminescence study...
AISI 5140 steel was plasma nitrided at various gas mixtures of nitrogen, hydrogen, and argon to investigate the actions of hydrogen and argon on plasma nitriding. The structural and mechanical properties of ion-nitrided AISI 5140 steel have been assessed by evaluating composition of phases, surface hardness, compound layer thickness, and case depth by using X-ray diffraction (XRD), microhardness tests, and scanning electron microscopy (SEM). It was found that the growth of compound layer can be controlled and the diffusion improved when the gas mixture includes H_2 gas. Additionally, it was determined that the amount of Ar in dual gas mixture must be at 20% minimum to obtain distinctive surface hardness and compound layer thickness.
In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral ...
Plasma triglyceride turnover was measured during steady-state conditions in 22 postoperative patients. Nine had received nutritional support with an enteral regimen, seven had received an equivalent regimen as continuous parenteral nutrition, and six received the same parenteral regimen as a cyclical infusion. After 5 days of nutritional support, each patient received an intravenous bolus of tritiated glycerol. Plasma radiolabeled triglyceride content was measured during the subsequent 24 hours. The data were analyzed by means of a simple deterministic model of plasma triglyceride kinetics and compared with the results obtained by stochastic analysis. The rates of hepatic triglyceride secretion obtained by deterministic analysis were higher than those obtained by the stochastic approach. However, the mode of delivery of the nutritional regimen did not affect the ...
... the major types of vascular access catheters: A peripherally inserted central catheter (PICC) is a long catheter that extends ... the procedure performed? A midline catheter and some peripherally inserted central catheter (PICC) lines may be inserted at your ...
Peripheral subunit binding domains (PSBDs) are integral parts of large multienzyme complexes involved in carbohydrate metabolism. PSBDs facilitate shuttling of prosthetic groups between different catalytic...Full Text Available
In honor of the 50th anniversary of the “organizational hypothesis,” this paper reviews work on sexual differentiation of the spinal cord and peripheral nervous system....Full Text Available
To investigate the role of thyroxine-binding globulin (TBG) and albumin in the availability of thyroid hormones to peripheral tissues, comprehensive kinetic studies of thyroxine (T4) and triiodothyronine...Full Text Available
Peripheral vascular diseases (PVD) are referred to as diseases affecting the blood vessels other than the heart and the brain. Interventional endovascular treatment whenever feasible has become the...Full Text Available
Ninety-four patients with peripheral arterial injuries were subjected to acute repair, negative exploration, or late repair of the complications of the arterial injury (false aneurysm, A-V fistula,...Full Text Available
In our quest for novel genes required for the development of the embryonic peripheral nervous system (PNS), we have performed three genetic screens using MAb 22C10 as a marker of terminally differentiated...Full Text Available
Peripheral vision has been the topic of few studies compared with central vision. Nevertheless, given that visual information covers all the visual field and that relevant information can...Full Text Available
This purpose of this paper is to describe the optimizing Peripherally Inserted Central Catheter (PICC) insertion, revising data collection strategies, estimating workloads, and calculating the financial savings generated by the vascular access nurse (VAN)...
BackgroundThiazolidinediones (TZDs) activate peroxisome proliferator-activated receptor gamma (PPARγ) and are used clinically to help restore peripheral insulin sensitivity...Full Text Available
Aims:To investigate the relationship between the duration of comatose state, severity of rhabdomyolysis and frequency of peripheral nerve injury (PNI) in patients following...Full Text Available
Grooving CVD diamond films using a focused ion beam (FIB) to quarry micro parts is described. The substrate-side surface of a polycrystalline diamond film which is prepared by means of microwave plasma CVD, is able to be grooved by a focused Ga ion beam scanned straight repeatedly. The groove has cross section whose shape is like an inverted Gaussian distribution curve. And the surface roughness of the films before grooved influences that of grooves. Under the same irradiation conditions, deeper, narrower, in short, high aspect ratio grooves are obtained on B-doped semiconducting microwave plasma CVD diamond films. Coating electrical conductive material is also effective method to obtain high aspect ratio grooves. It is supposed that these results are due to the degree of electrification on the surface and that FIB irradiation is a suitable method for micromachining semiconducting diamond films.
The mammalian circadian timing system is organized into hierarchical structures with a central clock in the suprachiasmatic nucleus (SCN) and subsidiary peripheral oscillators. After the discovery of the local clockwork in peripheral organs and tissues, which have a molecular makeup similar to the central pacemaker SCN, uncovering the roles of the peripheral clock in the rhythmic physiology has been an emerging goal in chronobiology. Glucocorticoid (GC) is a multifunctional adrenal steroid hormone that shows a robust circadian rhythm. The daily GC rhythm has long been thought to be governed by the SCN via the hypothalamus-pituitary-adrenal neuroendocrine axis. Recent findings, however, indicate that multiple regulatory mechanisms, including the adrenal intrinsic mechanism by the peripheral...
... in artificial intelligence, human physiology and biomedical prosthesis. ... central and peripheral nerve systems [1 ... CMOS circuit interface for multiplexed ...
High quality single-walled carbon nanotubes (SWNT) have been synthesized at large scales by the method of direct evaporation of carbon black and metallic catalyst mixtures, using induction thermal plasma technology. The processing system consists mainly of an RF plasma torch, which generates a plasma jet of extremely high temperature (?15 000 K), with a high energy density and abundance of reactive species (ions and neutrals). With the present reactor system, it has been demonstrated that carbon soot product which contains approximately 40 wt% of SWNT can be continuously synthesized at the high production rate of ?100 g h-1. The processing parameters involved have been examined closely in order to evaluate their individual influences on SWNT synthesis. The results have shown that the quality and purity of the SWNT produced are critically affected by the grade of carbon black, the plasma gas composition ...
Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite- length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to infuence the self-electric and self-magnetic fields when ?ce > ?pe?b, where ?ce = e?/mec is the electron gyrofrequency, ?pe is the electron ...
Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ...
Inductively coupled plasma etching of InGaP, AlInP and AlGaP in BI{sub 3} or BBr{sub 3} discharges was investigated as a function of source power, dc chuck bias and plasma composition. InGaP etches at the fastest rates ({gt}6000thinsp{Angstrom}thinspmin{sup {minus}1}) in both chemistries, followed by AlGaP. It is found that AlInP provides an excellent etch stop for the other two materials in both mixtures. The InGaP surface morphology improves with increasing BI{sub 3} or BBr{sub 3} content, and with increasing dc chuck bias. The etched features for this material are highly anisotropic. Etch selectivities for InGaP over SiO{sub 2} and SiN{sub x} of {ge}8 are obtained in both plasma chemistries, and there is no etch incubation time with either mixture, indicating that both can scavenge the native oxide on InGaP, AlGaP and AlInP. {copyright} {ital 1998 American Vacuum Society.}
Inductively coupled plasma etching of InGaP, AlInP and AlGaP in BI_3 or BBr_3 discharges was investigated as a function of source power, dc chuck bias and plasma composition. InGaP etches at the fastest rates (>6000 Angstrom min"-"1) in both chemistries, followed by AlGaP. It is found that AlInP provides an excellent etch stop for the other two materials in both mixtures. The InGaP surface morphology improves with increasing BI_3 or BBr_3 content, and with increasing dc chuck bias. The etched features for this material are highly anisotropic. Etch selectivities for InGaP over SiO_2 and SiN_x of #>=#8 are obtained in both plasma chemistries, and there is no etch incubation time with either mixture, indicating that both can scavenge the native oxide on InGaP, AlGaP and AlInP. copyright 1998 American Vacuum Society.
A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from Al laser-produced ...
The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to detect radiation effects in A-bomb survivors, RNA was extracted from about 10"7 ...
Recent two major topics of Large Helical Device (LHD) towards fusion relevant conditions, high-density operation and high-ion-temperature operation, are reported. Super dense core plasma was obtained by the combination of repetitive hydrogen ice pellet injection and high power neutral beam injection (NBI) heating. A very peaked density profile with the highest central density of 1.1x1021 m-3 was produced showing that the particle transport was suppressed very well in the plasma core. The spatial density varies as the position of magnetic axis (Rax), and the steepest profile is obtained at Rax=3.95 m. The highest central ion temperature of 5.6 keV was obtained in hydrogen plasma at electron density of 1.6 x 1019 m-3 by NBI, where a peaked ion-temperature profile with internal ion energy transport barrier was observed. The profile of electron temperature did not ...
We studied whether plasma-etching techniques can use standard screen-printed gridlines as etch masks to form self-aligned, patterned-emitter profiles on multicrystalline-silicon (mc-Si) cells from Solarex. We conducted an investigation of plasma deposition and etching processes on full-size mc-Si cells processed in commercial production lines, so that any improvements obtained would be immediately relevant to the PV industry. This investigation determined that reactive ion etching (RIE) is compatible with using standard, commercial, screen-printed gridlines as etch masks to form self-aligned, selectively doped emitter profiles. This process results in reduced gridline contact resistance when followed by plasma-enhanced chemical vapor deposition (PECVD) treatments, an undamaged emitter surface easily passivated by plasma-nitride, and a less heavily doped emitter between gridlines for ...
Fetal nucleated cells within maternal blood represent a potential source of fetal genes obtainable by venipuncture. The authors used monoclonal antibody against the transferrin receptor (TIR) to identify nucleated erythrocytes in the peripheral blood of pregnant women. Candidate fetal cells from 19 pregnancies were isolated by flow sorting at 12 1/2-17 weeks gestation. The DNA in these cells was amplified for a 222-base-pair (bp) sequence present on the short arm of the Y chromosome as proof that the cells were derived from the fetus. The amplified DNA was compared with standardized DNA concentrations. In the case of the female fetus, DNA prepared from samples at 32 weeks of gestation and cord blood at delivery also showed the presence of the Y chromosomal sequence, suggesting Y sequence mosaicism or translocation. In 10/12 cases where the 222-bp band was absent, the fetuses were female. Thus, they were successful in detecting the Y chromosomal ...
When the foundations of the building are designed and worked, the prediction calculation of immediate settlement of the building exercised practically is to calculate assuming the earth is a linear elastic body, but the actual stress-strain relationship of the earth is nonlinear and rigidity of the earth becomes lower as strain (or stress) increases. Hence in order to grasp the actual settling behavior of the earth, it is necessary to elucidate the nonlinear relationship between stress and strain. In this article, a prediction method of building settlement is introduced which uses an analytical technique of the multi-layered earth by the linear elasticity theory and takes into consideration strain dependency of rigidity of the earth. Part of the conclusion is as follows which has been obtained by studying the settling behaviors observed in examples of vertical loading tests of the pile foundations and the elasto-plastic settlement analytical method of the pile ...
Radiotherapy with high-energy carbon ion beams can be more advantageous compared to photons because of better physical dose distribution and higher biological efficiency in tumour cell sterilization. Despite enhanced normal tissue sparing, damage incurred by normal cells at the beam entrance is unavoidable and may affect the progeny of surviving cells in the form of inheritable cytogenetic alterations. Furthermore, the quality of the beam along the Bragg curve is modified by nuclear fragmentation of projectile and target nuclei in the body. We present an experimental approach based on the use of a polymethylmethacrylate (PMMA) phantom that allows the simultaneous exposure to a particle beam of several biological samples positioned at various depths along the beam path. The device was used to measure the biological effectiveness of a 60 MeV/amu carbon-ion beam at inducing chromosomal aberrations in G{sub 0}-human peripheral blood lymphocytes. Chromosome spreads were ...
Homidium bromide and isometamidium chloride are used extensively in the treatment of bovine trypanosomiasis in Africa, but no specific and sensitive method to detect the drug in plasma has been published yet. Comparing the methods of other investigators it was found that they could not overcome the protein binding of these drugs which reduced the available and determined drug to 10% of the real concentrations. These techniques overcome the protein binding by enzyme digestion and an alteration of the pH before adding the sample directly on clean-up columns. Drug recover rates above 80% were obtained. For the detection, the HPLC was employed using a C18 reversed phase analytical column and UV detection, determining both drugs as intact molecules. (author).
In this paper, a novel type of a corona discharge plasma reactor was designed, which consists of needle-plate-combined electrodes, in which a series of needle electrodes are placed in a glass container filled with flue gas, and a plate electrode is immersed in the water. Based on this model, the removal of NO and SO2 was tested experimentally. In addition, the effect of streamer polarity on the reduction of SO2 and NO was investigated in detail. The experimental results show that the corona wind formed between the high-voltage needle electrode and the water by corona discharge enhances the cleaning efficiency of the flue gas because of the presence of water, and the cleaning efficiency will increase with the increase of applied dc voltage within a definite range. The removal efficiency of SO2 up to 98%, and about 85% of NOx removal under suitable conditions is obtained in our experiments.
Ion beams of halogens can be produced either positively or negatively charged, depending on the employed ion source. At CERN-ISOLDE, although positively charged fluorine and astatine can be obtained from a hot plasma ion source, they are often contaminated by isobars and molecular sidebands. This has generated a request from the scientific community for fluorine and astatine negative ion beams free of contaminants. The high selectivity ensured by the surface ionisation process also makes negative beams of chlorine, bromine and iodine highly attractive. However, the efficiency figures for negative surface ionisation of fluorine and astatine were lower than the ones from the hot plasma. Here we report our R and D on new surface ion sources suitable for the production of negative halogen beams.
Samples of austenitic stainless steel AISI 316 were nitrided using the cathodic cage technique with the addition of methane in the nitriding atmosphere. The aim was to study the influence of this technique in reducing the precipitation of chromium nitrite and in improving the wear resistance. The results show that there was a significant improvement in such properties when compared to the results of ionic plasma nitriding. Formation of a double layer, one more internal composed of carbon and another with high nitrogen content, was confirmed by Scanning Electron Microscopy (SEM). The microhardness profile of the layer showed an increase in hardness values and a larger uniformity, while X-ray analysis showed less chromium nitriding precipitation when compared with results obtained for samples treated using ionic plasma nitriding.
A concept of direct energy recovery system applying an alternating or rotating magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. Nearly same amounts of residual positive and negative hydrogen-isotope ion beams with beam energy of {approx}1 MeV are produced in an NNB using a gas neutralizing cell. Consequently, a recovered energy is obtained directly in the form of ac electric power, if these positive- and negative-ion beams are alternated or rotated and introduced to two or more recovery electrodes in turn by an alternating or rotating magnetic field. This concept will greatly reduce a technological difficulty in regeneration of a recovered electric energy with such a very high voltage. (author).
Considering beryllium as plasma facing armour this paper presents recent results obtained in Russia. A special process of joining beryllium to a Cu-alloy material structure is described and recent results of thermal cycling tests of such joints are presented. Summarizing the results, the authors show that a Cu-alloy heat sink structure armoured with beryllium can survive high heat fluxes ({>=}10 MW/m{sup 2}) during 1000 heating/cooling cycles without serious damage to the armour material and its joint. The principal feasibility of thermal cycling of beryllium grades and their joints directly in the core of a nuclear reactor is demonstrated and the main results of this test are presented. The paper also describes the thermal cycling of different beryllium grades having cracks initiated by previously applied high heat loads simulating plasma disruptions. (orig.)
The history of the Czech Institute of Plasma Physics is highlighted. The article is structured as follows: Cyclic accelerators; Interaction of an external high-frequency field and high-temperature plasma - the tokamak; Interaction of an external high-frequency field and high-temperature plasma - pulse plasma systems; Low-temperature plasma - plasma technologies and new materials; Laser plasma - PALS; Optical diagnosis; and Teaching, conferences and international cooperation. (P.A.)
VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas...Full Text Available
One of the main causes of hip prostheses failure is the premature wear of its components. Wear of metal-on-metal joints is a concern due to the toxicity and biological reaction of wear debris and metallic corrosion. The main aim of the present study was to investigate the tribological and corrosion behavior of surface engineering CoCrMo alloy. Different surface conditions were obtained on surgical grade wrought CoCrMo alloy: plasma nitrided (520^oC by 7h at gas mixture of 10% N2+90% H2), PVD coated (monolayer CrN and multilayer (TiN/CrN)x3) and modified using duplex surface engineering technology (a combination of the two previous approaches: plasma nitriding followed by plasma assisted PVD). Surfaces were characterized using scanning electron microscopy, nanoindentation, AFM and scratch t...
A series of experiments have been conducted on AISI 5140 low alloy steel using a hollow cathode discharge-assisted plasma nitriding apparatus with the aim of elucidating the role of substrate bias voltages in plasma nitriding process. For comparison, some samples were nitrided with applied substrate bias (-50 V) while other samples were nitrided at floating potential. Treatments were carried out in NH{sub 3} atmosphere of 150 Pa at temperatures ranging from 450 {sup o}C to 550 {sup o}C for 2 h, 4 h, and 6 h. The nitrided samples were characterized by optical microscopy, X-ray diffraction and micro-hardness measurement. The corrosion behaviors were evaluated using anodic polarization tests in 3.5% NaCl solution. The results showed that the microstructure and phase constituents of the nitride layers were strongly influenced by the bias voltages. It was also demonstrated that the better corrosion resistance with a thicker nitrided layer was ...
A series of experiments have been conducted on AISI 5140 low alloy steel using a hollow cathode discharge-assisted plasma nitriding apparatus with the aim of elucidating the role of substrate bias voltages in plasma nitriding process. For comparison, some samples were nitrided with applied substrate bias (-50 V) while other samples were nitrided at floating potential. Treatments were carried out in NH_3 atmosphere of 150 Pa at temperatures ranging from 450 "oC to 550 "oC for 2 h, 4 h, and 6 h. The nitrided samples were characterized by optical microscopy, X-ray diffraction and micro-hardness measurement. The corrosion behaviors were evaluated using anodic polarization tests in 3.5% NaCl solution. The results showed that the microstructure and phase constituents of the nitride layers were strongly influenced by the bias voltages. It was also demonstrated that the better corrosion resistance with a thicker nitrided layer was ...
A wear-resistant nitrided layer was formed on a 304L austenitic stainless steel substrate by DC plasma nitriding. Effects of DC plasma nitriding parameters on the structural phases, micro-hardness and dry-sliding wear behavior of the nitrided layer were investigated by optical microscopy, X-ray diffraction, scanning electron microscopy, micro-hardness testing and ring-on-block wear testing. The results show that the highest surface hardness over a case depth of about 10 #mu#m is obtained after nitriding at 460 deg. C. XRD indicated a single expanded austenite phase and a single CrN nitride phase were formed at 350 deg. C and 480 deg. C, respectively. In addition, the S-phase layers formed on the samples provided the best dry-sliding wear resistance under the ring-on-block contact configuration test.
It has been clarified by the present authors, based on the plasma nitriding of Fe-Cr alloys and Fe-Ti alloys carried out at the temperature under 550{degree}C hitherto, that an internal nitriding layer is formed due to the fine dispersion of the particles of Cr nitride and Ti nitride in {gamma}{prime} Fe4N layer on the specimen surface. In this study, the plasma nitriding of Fe-Cr alloys are carried out at 650{degree}C, and the effects of the solute (Cr) content on the structures, nitride and the thickness distribution are examined. The main results obtained therefrom are indicated hereafter. In accordance with the observation on the cross-sectional structure of the alloys, only the nitriding layer deduced as the dispersion and precipitation of the particles of Cr nitride from {alpha}-Fe of the mother phase is formed, while {gamma}{prime}-Fe4N layer, which is found at the temperature under 550{degree}C, is not formed. The ...
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal ...
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal ...
Multiple treatment of engineering surfaces can provide improved surface properties that cannot be obtained by a single surface treatment. Consequently, this study investigates the effects of laser melting on the microstructures of plasma nitrided Ti-6Al-4V alloy. The study consists of two parts. In the first part, governing equations pertinent to the laser melting process are developed, and temperature variation across the melted zone is predicted. In the second, an experiment is conducted to nitride the surface of the alloy through plasma nitriding process and to melt the plasma nitrided and the untreated alloy surfaces with a CO2 laser beam. The resulting metallurgical changes are examined using x-ray diffraction (XRD), bdenergy-dispersive spectrometry (EDS), and scanning electron microscopy (SEM) techniques. It is shown that three distinct nitride layers are formed in the vicinity of the alloy ...
A novel continuous powder introduction microwave-induced plasma atomic emission spectrometry method (CPI-MIP-AES) has been developed for trace determination of metals in ground and tap water samples after preconcentration on activated carbon. The experimental setup consisted of integrated rectangular cavity TE_1_0_1 and vertically positioned plasma torch. The technical arrangement of the sample introduction system has been designed based on the fluidized bed concept. The satisfactory signal stability required for sequential analysis was attained owing to the vertical plasma configuration, as well as the plasma gas flow rate compatibility with sample introduction flow rate. The elements of interest (Cd, Cu, Cr, Fe, Mn, Pb, Zn) were preconcentrated in a batch procedure at pH 8-8.5 after addition of activated carbon and then, after filtering and drying of the activated carbon suspension, introduced to the ...
Cold plasma nitriding treatment was performed to improve the corrosion resistance of C38 carbon steel. Nitriding process was conducted using a radiofrequency nitrogen plasma discharge for different times of treatment on non-heated substrates. The modification of the corrosion resistance characteristic of the C38 steel due to the treatment in acid medium (1 M HCl) were investigated by gravimetric and electrochemical tests such as potentiodynamic polarisation curves and electrochemical impedance spectroscopy (EIS). It was shown that the plasma nitriding treatment improves the corrosion resistance. Indeed, in the gravimetric tests, nitrided samples showed lower weight loss and lower corrosion rate in comparison to untreated one. In the Tafel polarisation tests, the nitrided samples showed greatly reduced corrosion current densities, anodic dissolution and also retarded the hydrogen evolution reaction. Using EIS method, an ...
Some magnetron sputtering systems experience rapid oscillations in the current and voltage of the plasma discharge after several hours when equipped with certain targets. These oscillations often lead to the plasma becoming extinguished, a condition known as ''flame-out.'' This article details the study of two 90% W--10% Ti magnetron targets which differed in density. The higher density targets sometimes experienced flame-out after approximately 3 h of sputtering. The less dense material could be sputtered for the entire 15 h life of the target. Scanning electron microscopy pictures and atomic composition depth profiles were obtained using Auger electron spectroscopy. In addition, a Colutron-based ion source with a high vacuum system was used to measure ion-induced secondary electron emission coefficients as a function of energy, ion specie, and gas coverage. Analysis of the sample from the group that suffers flame-out ...
We compared the characteristics on thin-section CT images with the histological structure of thirty-four surgically resected peripheral lung lesions 30 mm or less in diameter with a greater than 50% area of GGA on thin-section CT. Pathologically, focal area of GGA corresponded to alveolar replacement growth of tumor or interstitial fibrotic thickening of inflammation. It is considered that determination of the GGA in small peripheral lung lesions on thin-section CT is useful for the diagnosis of early adenocarcinomas. (author)
About 210 abstracts by Ukrainian and foreign authors submitted to the 11-th International Conference on Plasma Physics and Controlled Fusion and 2-nd Alushta International Workshop on the Role of Electric Fields in Plasma Confinement in Stellarators and Tokamaks have been considered by Conference Program Committee members. All the abstracts have been divided into 9 groups: Magnetic confinement systems (stellarators, tokamaks, alternative conceptions); plasma heating and current drive; ITER and fusion reactor aspects; basic plasma physics; space plasma; plasma dynamics and plasma-wall interaction; plasma electronics; low temperature plasma and plasma technologies; plasma diagnostics.
... Ashton WS, Puntel RA, Wiswell TE. A rapid and readily available repair of the peripherally inserted central catheter in the nursery. NEONATAL INTENSIVE CARE 11 ...
... The study cohort consisted of 2,123 military working dogs that were ... maintained at the Department of Defense Military Working Dog Training Center ...
... dressing changes and site care, mid-line placement, placement of peripherally inserted central catheters, heparin locks, and patient education. ...
An inspection system was developed for spent fuel assemblies of PWR so that to check their general state, perform dimensional control and measure oxide layer thickness of peripheral rods. (orig./HP)
... and Cardiac Function test (including optional measurements of central venous pressure (CVP), via a peripherally inserted central catheter, and cardiac output ...
... in MEDCAP "the level of interface was left up ... of these patients had peripheral nerve injuries, head ... with poorly constructed prosthesis or waiting for ...
Restructuring was carried out on a sedimentary basin structure model of the Osaka plain including Osaka Bay by using newly obtained underground structural data. After the Hygoken-nanbu Earthquake of 1995, a large number of underground structure investigations have been performed in Osaka Bay and urban areas of Kobe and Osaka. However, very few surveys have been done in areas peripheral to Osaka Prefecture, such as the Ikoma area. Therefore, an attempt has been made to increase the number of measuring points to acquire underground structural data of these areas. Estimation of basic rock depths has utilized the dominant cycles in H/V spectra obtained from micro vibration survey, and good correlation of the base rock depths derived by a refraction exploration and a deep-bed boring investigation. With regard to bed division and P- and S- wave velocities in sedimentary beds in the Osaka sedimentary basin, an underground ...
In this work we report a study of the induced changes in structure and corrosion behavior of martensitic stainless steels nitrided by plasma immersion ion implantation (PI"3) at different previous heat treatments. The samples were characterized by x-ray diffraction and glancing angle x-ray diffraction, scanning electron microscopy, energy dispersive x-ray spectroscopy, and potentiodynamic measurements. Depending on the proportion of retained austenite in the unimplanted material, different phase transformations are obtained at lower and intermediate temperatures of nitrogen implantation. At higher temperatures, the great mobility of the chromium yields CrN segregations like spots in random distribution, and the #alpha#"'-martensite is degraded to#alpha#-Fe (ferrite). The nitrided layer thickness follows a fairly linear relationship with the temperature and a parabolic law with the process time. The corrosion resistance depends strongly on ...
Recently there has been much concern with the ability of plants to uptake heavy metals from their surroundings. With the development of instrumental techniques with low detection limits such as inductively coupled plasma-mass spectrometry (ICP-MS), attention is shifting toward achieving faster and more elegant ways of oxidizing the organic material inherent in environmental samples. Closed-vessel microwave dissolution was compared with conventional methods for the determination of concentrations of cerium, samarium, europium, terbium, uranium and thorium in a series of samples from the National Institute of Standards and Technology and from fields in Idaho. The ICP-MS technique exhibited detection limits in parts-per-trillion and linear calibration plots over three orders of magnitude for the elements under study. The results obtained by using nitric acid and hydrogen peroxide in a microwave digestion system for the analysis of reference ...
In the frame of the European Technology R and D program for ITER, and in the area of High Heat Flux plasma facing Components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, Hot Isostatic Pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most promising one, particularly when the HIPping manufacturing technology is used. Within this program, ENEA manufactured tungsten monoblock mock-ups by using the HIPping technology. The mock-ups were tested with respect to thermal fatigue and, upon screening tests, the best performance obtained was 15 MW/m{sup 2} for 200 cycles. One of these mock-ups was enclosed in the 'Paride' neutron irradiation campaign. This campaign has the scope of enlarging the available database on ...
In the frame of the European Technology R and D program for ITER, and in the area of High Heat Flux plasma facing Components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, Hot Isostatic Pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most promising one, particularly when the HIPping manufacturing technology is used. Within this program, ENEA manufactured tungsten monoblock mock-ups by using the HIPping technology. The mock-ups were tested with respect to thermal fatigue and, upon screening tests, the best performance obtained was 15 MW/m"2 for 200 cycles. One of these mock-ups was enclosed in the 'Paride' neutron irradiation campaign. This campaign has the scope of enlarging the available database on the performance ...
Recent results of experimental and theoretical investigations, carried out in the Institute of plasma Physics of the NSC KIPT, are presented in the report. The main problems of discussion are as follows: plasma confinement and heating in stellarators and electromagnetic traps; powerful quasi-steady-state plasma accelerators (QSPA); experiments relevant for ITER; fusion Plasma theory; methods of high temperature plasma diagnostics; plasma technology. The main prospects on the IPP investigators are discussed also.
New data about the structure of high-temperature resistant metalloceramic plasma sprayed coatings in micro and nano areas are presented. Application of the new instrumental methods: transmission electron microscopy combined with selected area electron diffraction mode is possible to obtain these data. The first layer in Ni based metallic bond coat shows nanocrystalline structure. External ceramic layer based on stabilised ZrO_2 is polycrystalline and contains both cubic and tetragonal crystalline phases. Local inhomogeneities in coatings phase composition are determined. (author)
Linear properties of ion temperature gradient (ITG) modes in helical systems are studied. The real frequency, growth rate, and eigenfunction are obtained for both stable and unstable cases by solving a kinetic integral equation with proper analytic continuation performed in the complex frequency plane. Based on the model magnetic configuration for toroidal helical systems like the Large Helical Device (LHD), dependences of the ITG mode properties on various plasma equilibrium parameters are investigated. Particularly, relative effects of {nabla}B-curvature drifts driven by the toroidicity and by the helical ripples are examined in order to compare the ITG modes in helical systems with those in tokamaks. (author)
The authors made peritoneal dialisis with 5% of glucose (7 ml/kg of body weight) in 11 dogs under the conditions of an acute experiments. They examined cortiosl and ADH activity, hematocrite and plasma protein in the samples of blood, obtained on the 20th and 50th minute. ADH was titrated biologicaly by a new method, proposed by Nacev. The results were compared with the changes in the circulatory and renal indices, obtained at the same procedure in the preceding investigations. There was an increase in the cortisol and ADH activity, which could be explained by the total hypovolemia, induced by peritoneal dialisis. The increase of the cortisol level is described as a separate link in a more complex mechanism, assuring metabolic homeostasis. PMID:1222705
This report describes a technique of inserting an implantable venous access port (portacath) through a thrombosed and occluded vein employing a pre-existing peripherally inserted central catheter (PICC) as the route of access. The PICC was used as a conduit for venous access in a way that has not been described previously in the literature. This procedure was performed in a young patient with cystic fibrosis in an effort to prevent the use of his virgin contralateral veins, which might be used in the future.
A population-based, cohort study was conducted to determine the importance of Gulf War deployment to Southwest Asia, from 1 August 1990 to 31 December 1991, in explaining neurologic mortality and peripheral nerve disease among United States military worki...
To elucidate the dynamic features of CT scans in peripheral cholangiocarcinoma for the differentiation of this tumor from various primary hepatic neoplasms. Materials were 24 cases of pathologically confirmed peripheral cholangiocarcinoma. Contrast enhancement patterns of central and peripheral portion of the masses were analyzed at three phases including arterial dominant(22), tissue equilibria(24), and postequilibria(9). Other associated CT findings and laboratory data were analyzed. Serum total bilirubin was mostly below 2 mg/dl(22/24), hepatitis B surface antigen was positive in only 9%, serum alphafetoprotein was elevated in 18%, carcinoembryonic antigen in 47%, cancer antigen 19-9 in 60%. In the arterial dominant image(22), 50% of the cases showed peripheral hyperdensity and 50% total hypodensity. In the tissue equilibrial images(24), 63% showed total hypodensity, 25% ...
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).
32P-Postlabeling analysis and enzyme-linked immunosorbent assay (ELISA) have been used to detect DNA adducts in peripheral blood lymphocytes from primary aluminum production plant workers who were exposed...Full Text Available
"9"9"mTc-tetrofosmin has been used in the imaging of cancers of diverse origin. In this report the use of it in the family of round cell tumors, mainly Ewing's sarcoma and peripheral neuroectodermal tumor (PNET), where differentiation between the two is not always simple on the basis of histopathological features alone is discussed
This report results from a contract tasking Eindhoven University of Technology as follows: The contractor will investigate the plasma treatment of surfaces and plasma enhanced deposition using EUT's cascade arc source as the basis for this effort.
The major activities of the various Institute's departments are highlighted. The following departments are included: (i) Tokamak; (ii) Pulse plasma systems; (iii) Thermal plasma; (iv) Materials engineering; (v) Laser plasma; and (vi) Optical diagnosis. (P.A.)
Results are described of a study and of the characteristics of sources of a non-equilibrium gas-discharge plasma. The plasma generators considered include glow, high frequency, and arc discharge generators. Thermodynamic, ionic, and electronic processes occurring in the plasmas are evaluated.
Nitrogen has been added to stainless steels to improve mechanical strength and corrosion resistance. High nitrogen steel production is limited by high gas pressure requirements and low nitrogen solubility in the melt. One way to overcome this limitation is the addition of nitrogen in solid state because of its higher solubility in austenite. However, gas and salt bath nitriding have been done at temperatures around 550 C, where nitrogen solubility in the steel is still very low. High temperature nitriding has been, thus proposed to increase nitrogen contents in the steel but the presence of oxide layers on top of the steel is a barrier to nitrogen intake. In this paper a modified plasma nitriding process is proposed. The first step of this process is a hydrogen plasma sputtering for oxide removal, exposing active steel surface improving nitrogen pickup. This is followed by a nitriding step where high nitrogen contents are introduced in the ...
Nitrogen has been added to stainless steels to improve mechanical strength and corrosion resistance. High nitrogen steel production is limited by high gas pressure requirements and low nitrogen solubility in the melt. One way to overcome this limitation is the addition of nitrogen in solid state because of its higher solubility in austenite. However, gas and salt bath nitriding have been done at temperatures around 550 C, where nitrogen solubility in the steel is still very low. High temperature nitriding has been, thus proposed to increase nitrogen contents in the steel but the presence of oxide layers on top of the steel is a barrier to nitrogen intake. In this paper a modified plasma nitriding process is proposed. The first step of this process is a hydrogen plasma sputtering for oxide removal, exposing active steel surface improving nitrogen pickup. This is followed by a nitriding step where high nitrogen contents are introduced in the ...
This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ideal ...
Dust particles in a plasma are charged negatively and are subject to various types of forces, including a drag force by plasma particles and a force due to the collective nature of a plasma. Dust particles are found in a sheath in laboratories balanced by the gravitational force and the electric force, while dust particles in space are ubiquitous, including planetary magnetospheres and interstellar space. Because of the novel nature of a complex system involving plasma particles and dust particles in a collective way, the dusty plasma is often called a complex plasma. The complex plasma is characterized by two distinctly different scales in time and in space. The plasma with electrons, ions and neutrals is characterized by the collective motion with a fast time scale and a short wavelength, while the dust particles move ...
Excitation of the HF electric field in the local plasma resonance region (LPRR) of inhomogeneous plasma by pumping electric field or modulated electron beam results to appearance of the ponderomotive force that presses plasma out of this region. Density cavity is formed in the LPRR due to this field. Further dynamics in this region depends on the plasma properties. For plasma with hot electrons ion-acoustic pulses run away from the cavity. at the local density maximum the new peak of electric field is excited. It results to the formation of new density cavity, etc. For isothermal plasma the density jump is formed.
The expanding plasma produced when an intense pulse of laser radiation is focused in vacuum onto a solid target has been used as a source of highly stripped ions for collision cross-section measurements. Usable fluxes of carbon nuclei at energies of a few hundred eV/charge have been obtained by irradiation of graphite with pulses of CO"2 laser radiation at a focused power density of 3 x 10_1_0 W/cm_2. Bombardment of aluminum and iron targets at comparable power levels have yielded ions of maximum charges of 9 and 16 respectively. A time-of-flight apparatus has been constructed to utilize the laser source for measurement of electron capture cross sections for highly stripped ions in gases at energies in the few hundred eV/charge range. Apertures collimate an ion beam from the plasma blowoff, and an electrostatic analyzer selects ions from the expanding plasma which have the same energy per charge. The ...
An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found ...
As a hardening process, the attractiveness of nitriding lies in its low treatment temperature. Although the thickness of the case is less than that obtained by higher temperature processes such as carburising, there are a range of alloys and applications for which nitriding is the only possible alternative. Indeed, there are some alloys and applications for which even the normal nitriding temperatures (between 500 deg C and 600 deg C for ferrous alloys) are too high. In this paper, we report on developments, specifically the use of low pressure plasmas and high energy ion bombardment, which can extend the benefits of nitriding to lower temperatures. In this poster, we will present results from these collaborative projects, concentrating on the nitriding of austenitic stainless steel at temperatures below 450 deg C. In this temperature range, the hardness and wear resistance of the surface can be improved without compromising the corrosion ...
This paper builds on earlier work to give a consistent treatment of the positive column of discharges in electronegative gases covering the transition from collisionless to collisional. In particular it seeks to elucidate the conditions under which there is an ion-ion plasma core surrounded by an electron-ion plasma, and when there is not. The parameters which describe the processes of ionization, attachment, detachment and recombination are related to the central negative ion density relative to the electron density and, where appropriate, the size of the core. The use, by earlier workers, of the Boltzmann approximation to describe the negative ion distribution and to obtain ambipolar diffusion coefficients at higher pressures is shown not to be justified. This leads to the clarification of an inconsistency in the literature. Where possible, the work is related to other recent treatments of the same problem in order to ...
In the frame of the European Technology R and D programme for International thermonuclear experimental reactor (ITER) and in the area of high heat flux plasma facing components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, hot isostatic pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most robust one, particularly when the HIPping manufacturing technology is used. Within this programme, ENEA developed an alternative technique for manufacturing plasma-facing components with a monoblock geometry of the ITER machine. The basic idea of this technique, named hot radial pressing (HRP), is to perform a radial diffusion bonding between the cooling tube and the armour tile by pressurising the internal tube only and by keeping the ...
Interpretative transport has been used to revisit the global scalings of TJ-II ECRH plasmas from a local perspective. Density, rotational transform and ERCH power scans were analysed based upon Thomson Scattering data (electron density and temperature) in steady state discharges. A simple formula to obtain the thermal conductivity, assuming pure diffusion and negligible convective heat fluxes was used in a set of 161 discharges. All the analysis was performed with the ASTRA transport shell. The density scan indicates that inside n=0,4 there is no significant change of e with density in the range studied (0.4 <ne>(1019m-3) 1.0), while in 0,5 <0,8 approximately, e decreases with density. In the rotational transform scan it is found that the values of e when a low order rational of the rotational transform is present locally seem to be smaller for the corresponding range, although it is apparent a general beneficial effect of ...
A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a flexibility of the magnetic field configuration is realized. For the case that the rotational transform crosses the low-order rational value resulting ...
Experimental and theoretical research has been conducted jointly at the Livermore and Los Alamos National laboratories on dc electromagnetic railgun Lorentz accelerators. Pellets weighing a few grams to tens of grams have been launched at velocities up to better than 11 km/s. The research is addressed to attaining repeated launches of samples at hypervelocity in target impact experiments. In these experiments, shock-induced pressures in the tens of megabars range are obtained for high pressure equation-of-state research. Primary energy sources of the order of several hundred kJ to a MJ and induction currents of the order of 1 or more MA are necessary for these launches. Erosion and deformation of the conductor rails and the accelerated sample material are continuing problems. The heating, stress, and erosion resulting from simultaneous imposition of rail induction current, dense plasma (armature) interaction, current distribution, magnetic ...
A multicusp magnetic field plasma surface ion source, normally used for H/sup /minus//ion beam formation, has been modified for the generation of high-intensity, pulsed, heavy negative ion beams suitable for a variety of uses. To date, the source has been utilized to produce mA intensity pulsed beams of more than 24 species. A brief description of the source, and basic pulsed-mode operational data, (e.g., intensity versus cesium oven temperature, sputter probe voltage, and discharge pressure), are given. In addition, illustrative examples of intensity versus time and the mass distributions of ion beams extracted from a number of samples along with emittance data, are also presented. Preliminary results obtained during dc operation of the source under low discharge power conditions suggest that sources of this type may also be used to produce high-intensity (mA) dc beams. The results of these investigations are given, as well, and the technical ...
Cholangiocarcinoma is synonymous with bile duct carcinoma, and can originate in a small intrahepatic bile duct (peripheral type), a major intrahepatic duct including the hepatic hills, an extrahepatic duct, or near the papilla of Vater (central type). In a sense bile duct carcinoma of the peripheral type is cholangiocarcinoma of the liver; it has the same gross configuration as hepatocellular carcinoma, resulting in difficulty to differentiate on the CT. The authors studied CT findings of 14 cases of pathologically proven peripheral type cholangiocarcinoma of the liver during the last 4 years. The results were as follows: 1. Of 14 cases, 8 were female and 6 were male, and the age ranged from 5th to 7th decades. 2. Preoperative clinical diagnosis were as follows: hepatoma 8 cases, abscess 5 cases and metastasis 1 case in order of frequency. 3. Diagnosis were confirmed by hepatic lobectomy in 7 cases, wedge resection in 5 ...
Background/Purpose: Peripherally inserted central venous catheters (PICCs) are commonly used for neonatal vascular access. The aim of this study was to look at PICC line complication rates and possible predictors of PICC infection in a neonatal intensive care unit. Method: This was a prospective study of 226 neonates who had PICCs on our neonatal intensive care unit between January 2006 and June 2009. Complete data was available on 218 neonates who had 294 PICC lines. Criteria for catheter-related sepsis was positive blood cultures (peripheral/central) and/or a positive catheter tip culture after removal in the presence of a clinical suspicion of line sepsis. Results: Of 218 neonates, 132 (169 lines) were medical, and 86 (125 lines) were surgical. Our PICC line infection rate was 17 infect...
PulsPlasma nitriding is now one of the established nitriding methods. This article describes PulsPlasma nitriding procedures and the boundary conditions necessary. The special features of PulsPlasma technology compared to DC plasma systems are illustrated. In addition, the process benefits of material treatment using a plasma are examined, as is system type. The article concludes with typical applications of PulsPlasma technology for treatment of stainless steel, cold-working steel, hot-working steel and sintered steel. (orig.)
The plasma cladding waveguide, which is a cylindrical dielectric core surrounded by a plasma cladding, is developed, and the guided modes and their characteristics of this waveguide are displayed through the present detailed theoretical research. The conditions of the single mode existing in the plasma cladding waveguide have been given, and the defined forbidden gap of frequency is discussed. It is found that the usage characteristics of the plasma cladding waveguide vary strongly with plasma frequency, and changing the plasma parameters can control the propagation mode. This paper focuses on exhibiting the basic characteristics and the potential applications of this new type of waveguide.
Experimentally it is shown that a movable grounded metallic plate placed inside a multi-dipole magnetic cage can vary the diffused plasma parameters such as density, plasma potential and electron temperature. Plasma is solely produced in the source section of a double plasma device by a dc hot filament discharge and a low-density plasma is produced in the target section by local ionization of neutral gas by the high energetic electrons coming from the source section. A grounded movable stainless steel plate is inserted in the target section of the device. The floating potential of the plate also changes depending on the position of the plate inside the magnetic cage.
Technology developments in semiconductor fabrication along with a rapid expansion of the market for portable devices, such as PDAs and mobile phones, make the energy consumption of embedded systems a major problem. Indeed the need to provide an increasing number of computational intensive applications and at the same time to maximize the battery life of portable devices can be seen as incompatible trends. System simulation is a flexible and convenient method for analyzinging and exploring the performance of a system or sub-system. At the same time, the increasing use of computational intensive applications strengthens the need to maximize the battery life of portable devices. As a consequence, the simulation of embedded systems for energy consumption estimation is becoming essential in order to study and explore the influence of system design choices on the system energy consumption. The original publications presented in the second part of this thesis propose several frameworks for ...
1. Choline, and the choline analogues monoethylcholine (MEC) and N-aminodeanol (NAD) were examined for prophylactic activity in acute acetylcholinesterase inhibitor toxicity in mice. The rank order of potency of the compounds was MEC greater than NAD greater than choline. 2. Simultaneous administration of MEC (60 mg kg-1) or NAD (200 mg kg-1) with physostigmine reduced lethality to 17 and 13% respectively. MEC (60 mg kg-1) completely protected against disopropylfluorophosphate (DFP) and diazinon toxicity, and NAD reduced lethality to 17% for both agents. Choline (200 mg kg-1) exhibited only negligible antidotal activity against the inhibitors. 3. In vitro concentrations of choline, MEC, and NAD, similar to the estimated concentration obtained in vivo in the acute toxicity study, produced mixed inhibition of mouse brain acetylcholinesterase. The inhibition was dose-related and was additive to the inhibition produced by the cholinesterase inhibitors. 4. All three ...
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with ...
The application of the large-bore direct injection high efficiency nebulizer (LB-DIHEN) for the determination of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) in urine by inductively coupled plasma mass spectrometry (ICP-MS) is described. The LB-DIHEN is compared with the standard method using a concentric pneumatic nebulizer and cyclonic spray chamber. In addition to the toxicological significance of As, Cd, Pb, and Hg, these elements represent a cross-section of analytical issues including spectral interferences (e.g., {sup 40}Ar{sup 35}Cl{sup +} on {sup 75}As{sup +} and {sup 98}Mo{sup 16}O{sup +} on {sup 114}Cd{sup +}) and memory effects (Hg). In this study, the low sample consumption of the LB-DIHEN is used to reduce the volume of urine needed for analysis, and to reduce the volume of final diluted sample required for analysis. Eliminating the spray chamber and reducing the dead volume of the nebulizer reduces memory effects, especially for analytes ...
Plasma nitriding of a Ti substrate is carried out under a low ambient pressure below 3kPa, and a plasma torch is prepared on a trial basis which is provided with a supersonic expansion nozzle considered to expand plasma jet optimally and to be effective for suppressing the occurrence of shock wave. The system used for the study is provided with a specimen holder having the function of adjusting the distance between the nozzle outlet and the substrate inside the vacuum chamber which is provided with a plasma torch in the flange member. The plasma torch is so structured that a supersonic expansion nozzle can be installed at the tip of the plasma torch. In this process wherein plasma jet is employed, hard nitrided layer can be formed by plasma irradiation for a short time even under such low pressure as less than 3kPa by ...
Experiments of plasma nitriding of titanium are carried out by two plasma sources. One is a microwave discharge plasma source under several Torr, and the other is a nitrogen arc jet generated under atmospheric pressure followed by rapid expansion into a gas wind tunnel. The relationship between the surface density of nitrogen atoms in the #alpha#-Ti and various plasma parameters is systematically studied. For the microwave nitrogen plasma, it is found that the effect of the vibration temperature is the most essential for the surface nitriding, whereas the effect of electron temperature, density and rotation temperature is less remarkable. It is also found that the higher vibration temperature of the microwave discharge nitrogen plasma makes the target temperature higher, and consequently, the surface density of atomic nitrogen remarkably increased. However, the ...
The central nervous system regulates peripheral immune responses via the vagus nerve, the primary neural component of the cholinergic anti-inflammatory pathway. Electrical stimulation of the...Full Text Available
Splice products of the Kiss1 protein (kisspeptins) have been shown to be involved in a diverse range of functions, including puberty, metastasis and vasoconstriction in large human arteries. Circulating...Full Text Available
... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...
BackgroundThe study of small airway diseases such as post-transplant bronchiolitis obliterans syndrome (BOS) is hampered by the difficulty in assessing peripheral airway function...Full Text Available
The study of blocking factors requires in vitro assay of cell mediated immunity that parallels the in vivo response. By microcytotoxicity testing, progressor and immune peripheral blood lymphocytes...Full Text Available
BackgroundThe circadian rhythm in mammals is orchestrated by a central pacemaker in the brain, but most peripheral tissues contain their own intrinsic circadian oscillators. The...Full Text Available
BackgroundSubjects with a ring scotoma can use two retinal loci, a foveal and a peripheral, for reading. Our aim was to investigate the relative use of both retinal loci as a function...Full Text Available
Interleukin 2 (IL-2) and B-cell growth factors I and II (BCGF I and BCGF II) are lymphokines produced by T cells that play a major role in T- and B-cell cooperation. Peripheral blood lymphocytes from...Full Text Available
Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der ...
In this work, coals of various ranks were dissolved in an acid melange. With the use of IR spectroscopy, it was found that the mechanism of coal dissolution consists in the grafting of polar groups to the peripheral benzene rings of graphite-like systems.
Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship between the lesions and the adjacent neurovascular structures and ...
The mammalian circadian system consists of a central oscillator in the suprachiasmatic nucleus of the hypothalamus, which coordinates peripheral clocks in organs throughout the body. Although circadian...Full Text Available
A 37 year old male was referred to our centre for management of episcleritis with peripheral keratitis in the right eye. He had a history of ocular discomfort in the right eye of 1 week duration. Slitlamp...Full Text Available
DNA from the peripheral blood mononuclear cells of 17 different individuals infected with human T-cell lymphoma/leukemia virus type II (HTLV-II) was successfully amplified by the polymerase chain reaction...Full Text Available
The endoplasmic reticulum (ER) is a continuous membrane system comprising the nuclear envelope, ribosome-studded peripheral sheets and an interconnected network of smooth tubules extending throughout...Full Text Available
ObjectivesThe aim of this study was to investigate the effect of cigarette smoking on clinical parameters and signs anemia of chronic disease in chronic periodontitis patients.Full Text Available
The immunogenicity of allogeneic cultured human epidermal keratinocytes (cHEKs) has been studied in several models with contradictory results. We studied human T-cell activation in an in vitro...Full Text Available
Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available
BackgroundIn sub-Saharan Africa, Plasmodium falciparum malaria in pregnancy presents an enormous diagnostic challenge. The epidemiological and clinical relevance...Full Text Available
This study was designed to identify the causes of the development of carpal tunnel syndrome (CTS) associated with end stage kidney disease (ESKD). A total of 112 patients with ESKD, 64 on hemodialysis...Full Text Available
Motor function requires that motor axons extend from the spinal cord at regular intervals and that they are myelinated by Schwann cells. Little attention has been given to another cellular structure,...Full Text Available
The bulbar conjunctiva is one of the few areas in which blood flow in the peripheral vasculature can be directly and noninvasively observed in the human. Although extensive literature exists describing...Full Text Available
- flushing Chemotherapy - what to ask your doctor Dry Mouth Oral mucositis Peripherally inserted central catheter Radiation therapy - what to ask your doctor Safe drinking during...
BackgroundFabry patients have symptoms and signs compatible with autonomic dysfunction. These symptoms and signs are considered to be due to impairment of the peripheral nervous...Full Text Available
BackgroundPostnatal glucocorticoid therapy in premature infants diminishes chronic lung disease, but it also increases the risk of hypertension in adulthood. Since glucocorticoid...Full Text Available
Calcium ions represent universal second messengers within neuronal cells integrating multiple cellular functions, such as release of neurotransmitters, gene expression, proliferation, excitability,...Full Text Available
Cortical bone contributes the majority of overall bone mass and bears the bulk of axial loads in the peripheral skeleton. Bone metabolic disorders often are manifested by cortical microstructural changes...Full Text Available
BACKGROUND--Interstitial lung diseases are characterised by the recruitment of mononuclear cells to disease sites where maturation occurs and activation products, including lysozyme (LZM), are released....Full Text Available
Alumina-reinforced carbon nanofiber nanocomposites were prepared using different routes; powders mixture, colloidal route and sol?gel process followed by spark plasma sintering (SPS). CNFs/xAl2O3 (x = 10?50 vol.%) were prepared through nanopowders mixing in a high-energy attrition milling. The main limitations in the preparation of this kind of nanocomposites are related to the difficulty in obtaining materials with a homogeneous distribution of both phases and the different chemical nature of CNFs and Al2O3, which causes poor interaction between them. A surface coating of CNFs by wet chemical routes with an alumina precursor is proposed as a very effective way to improve the interaction between CNFs and Al2O3. An improvement of 50% in fracture strength was found for similar nanocomposite ...
The rationale for hybrid fusion-fission reactors is the production of fissile fuel for fission reactors. A new class of reactor, the fission-suppressed hybrid promises unusually good safety features as well as the ability to support 25 light-water reactors of the same nuclear power rating, or even more high-conversion-ratio reactors such as the heavy-water type. One 4000-MW nuclear hybrid can produce 7200 kg of /sup 233/U per year. To obtain good economics, injector efficiency times plasma gain (eta/sub i/Q) should be greater than 2, the wall load should be greater than 1 MW m/sup -2/, and the hybrid should cost less than 6 times the cost of a light-water reactor. Introduction rates for the fission-suppressed hybrid are unusually rapid.
The validity is given to the newly proposed two weighting {delta}f scheme (Wang et al., Research Report of National Institute for Fusion Science NIFS-588, 1999) for collisional or neoclassical transport calculations, which can solve the drift kinetic equation taking account of effects of steep plasma gradients, large radial electric field, finite banana width, and the non-standard orbit topology near the axis. The marker density functions in weight equations are successively solved by using the idea of {delta}f method and a hierarchy of equations for weight and marker density functions is obtained. These hierarchy equations are solved by choosing an appropriate source function for each marker density. Thus the validity of the two weighting {delta}f scheme is mathematically proved. (author)
The PERMCAT is a membrane reactor proposed for processing fusion reactor plasma exhaust gas: tritium removal is obtained by isotopic swamping operating in counter-current mode. In this work, a membrane reactor using a permeator tube of length about 500 mm produced via diffusion welding of Pd-Ag thin foils is described. An appropriate mechanical design of the membrane module has been developed in order to avoid any significant compressive and bending stresses on the very long and thin wall permeator tube: two expanded bellows have been applied to the Pd-Ag tube, so that it has been pre-tensioned before operating. The elongation of the metal permeator under hydrogenation has been theoretically estimated and experimentally verified for properly designing the membrane reactor.
Lithium phosphorous oxynitride(Lipon) thin films as a lithium ion conductive electrolyte were prepared by radio frequency reactive sputtering in N2 plasma. The properties of the amorphous Lipon solid electrolyte were investigated as a function of N2 pressure during reactive sputtering. The ionic conductivity and the electrochemical stability of Lipon thin films improved drastically as the N2 pressure decreased. The ionic conductivity closed to 10?6 S cm?1 and obtained a stability window of 1.0?5.0 V with an N2 pressure of 5 mTorr, where the number of nitrogen bonds between the phosphate groups were more than those formed at higher pressure. It was possible to fabricate the Li//LiCoO2 complete thin film battery using this Lipon solid electrolyte, which exhibited excellent discharge characte...
A reference design was used in preparing a mathematical model of a fusion power plant with a tokamak reactor to investigate the extent to which the uncertainty still inherent in the physical reactor parameters affects the power costs. While only limited reductions of the power costs are achieved by improvements of the reference values for the reactor burn time, power density in the torus and load on the first wall, the power costs rise in keeping with the extent to which these parameters fall short of the reference values. As the results obtained in present-day experiments are still well below the reference values, a great deal of effort is still required in the fields of plasma physics and materials research to achieve an economically operating fusion power plant. (orig.).
Possible accident scenarios for a fusion reactor include breaches in the vacuum or cooling system. Intruding air or steam could react with structural or plasma facing materials, possibly mobilizing radioactive isotopes. Safety assessments must consider the early dose at the site boundary from the release of these activated materials. Previous calculations have indicated that cobalt isotopes dominate dose calculations for designs using stainless steel. Values used in these calculations, however, had been largely determined by the measurement limits of the chemical analysis methodology instead of measured releases. The purpose of the current study was to refine the analytical method to reduce the limit for detecting cobalt, and then test PCA steel in air and steam between 973 and 1473 K. Goals were to obtain more accurate measurements of cobalt mobilization in terms of g/m{sup 2}{center_dot}h and insight into the mobilization mechanisms.
Background: Apheresis is a procedure to selectively obtain blood components. For the collection process citrate is routinely used. It inhibits coagulation by binding to ionized calcium and leads to metabolic alkalosis. Objective: Whether regular apheresis affects bone and mineral metabolism is unknown. The intention of this study was to investigate 1) the acute effects of apheresis on acid-base balance, bone and mineral metabolism and 2) to compare bone mineral density (BMD) at the lumbar spine and hip of donors to matched control subjects. Design: In this open, observational, single-center, cross-sectional study we enrolled 102 regular plasma and thrombocyte donors to pursue objective 1) and compared those to 102 matched controls (CTR) for objective 2). Results: Platelet donation led to s...
The combined processes of plasma nitriding and cathodic arc deposition of (Ti,Cr,Nb)CN coatings were applied to HSS substrates. The nitrided layers, obtained in a mixture of H2 (70%) and N2 (30%) at two different temperatures (480^oC and 510^oC), were examined for the microhardness depth profiles. Characterization of the duplex coatings was performed by investigating elemental and phase composition, texture, hardness, friction and wear. XRD and XPS analyses revealed the formation of a mixture of a carbonitride fcc solid solution, in a dominant proportion, and metallic chromium. The film hardness was measured to be ~34GPa. The duplex (Ti,Cr,Nb)CN coatings exhibited superior tribological behavior as compared to both nitrided layers and non-duplex coatings.
The most important results of theoretical and experimental studies of plasmas, which have been achieved at the IPJ in Swierk and IPPLM in Warsaw recently, are presented. Studies of physical phenomena in PF discharges, development of diagnostic techniques and research on new plasma technologies, as performed at IPJ, have been summarized. Studies of dense magnetized plasmas, investigation of physics and applications of laser-produced plasmas; and research on the development of advanced diagnostic techniques for the EUROATOM fusion program, as performed at IPPLM, are also described.
Classical beam line ion implantation is limited to low energies and cannot achieve P+/N junctions requested for <45nm ITRS node. RTA (rapid thermal annealing) needs to be improved for dopants activation and damage reductions. Spike annealing process also induces a large diffusion mainly due to TED (transient enhanced diffusion). Compared to conventional beam line ion implantation limited to a minimum energy implantation of 200eV, plasma immersion ion implantation (PIII) is an emerging technique to get ultimate shallow profiles (as-implanted) due to no lower limitation of energy and high dose rate. On the another hand, laser thermal processing (LTP) allows to obtain very shallow junction with no TED, abrupt profile and activated depth control. In this paper, we show the implementation of the BF_3 PIII associated with the LTP. Ions from BF_3"+ plasma have been implanted in 200mm n-type silicon wafers with energies from ...
A compact cesium deposition system was used for direct deposition of cesium atoms and ions onto the inner surface of the 1/3 scale Hydrogen Negative Ion Source for the LHD-NBI system. A small, well defined amount of cesium deposition in the range of 3-200 mg was tested. Negative ion extraction and acceleration were carried out both in the pure hydrogen operation mode and in the cesium mode. Single Cs deposition of 3-30 mg to the plasma chamber have produced temporary 2-5 times increases of H-yield, but the yield was decreased within several discharge pulses to the previous steady-state value. Two consecutive 30 mg depositions done within a 3-5 hours/60 shot interval, produced a similar temporary increase of H-beam, but reached a larger H-yield steady-state value. Deposition of larger 0.1-0.2 g Cs portions with a 20-120 hours/150-270 shot interval improved the H-yield for a long (2-5 days) period of operation. Directed depositions of Cs to the various walls of the ...
In the present paper a procedure is proposed for the determination of traces of Cd, Co, Mn and Cr in petroleum industry produced water by inductively coupled plasma optical emission spectrometry. The procedure is based on cloud point extraction of these metals, as their dithizonate complexes, into the surfactant-rich phase of octylphenoxypolyethoxyethanol surfactant (Triton X-114). Extractions were carried out in solutions with salinities between 10 per mille and 70 per mille. Since residual salinity in the surfactant-rich phase caused differences in its transport to the plasma, yttrium was used as an internal standard to correct for this effect. The simultaneous metal extraction procedure was optimized by response surface methodology using a Doehlert design and desirability function. Enhancement factors of 21, 21, 9 and 19, along with limits of quantification of 0.093, 0.20, 0.73 and 1.2 #mu#g L"-"1, and precision expressed as relative ...
ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of ...
A new multicusp H{sup -} ion source using a Localized Virtual magnetic filter of type I [Ref.6] in the plasma electrode is investigated. A multipole (MP) arrangement with a spacing of 10 mm of the magnet bars holds an extraction hole, optimizing the efficient production of high H{sup -} current, and at the same time only a small electron component was co-extracted with the H{sup -} ions. The local filter arrangement separates the beam electrons at a low energy. It is shown that the co-extracted total electron current is determined principally by the integrated magnetic field flux (Gcm) of the local filter with an extraction system at a constant extraction voltage. When the value of the Gcm is increased, the total electron component is reduced, while the H{sup -} electrical efficiency had a broad maximum around the optimized value of the Gcm. A thicker plasma electrode should be necessary for sufficient reduction of electron current. In pure ...
This third report covers the period October 1 to November 30, 1991. During this period the authors: (1) fabricated a test fixture for studying hybrid armature brush behavior, (2) reactivated a 140kJ, 1MA capacitor bank, (3) reactivated 25 channels digital data acquisition and reduction system and (4) concluded the use of a DNA funded railgun would serve as the most expedient means to acquire a railgun test bed. Fabrication of a plasma brush test fixture for studying the formation, evolution and stability of plasma brushes was completed. The fixture will serve to study plasma brush parameters, such as brush length and voltage drop, as a function of initial solid foil mass, gap size and current concentration. A 4OkV, 168{mu}f, 140kJ capacitor bank capable of providing more than 1MA of current was reactivated. (The LLNL bank had been developed for opening switch research which was successfully completed.) The bank will be used ...
Burnout data with low pressure Freon-113 for even- and odd- numbered peripheral rod clusters with relatively large spacings were used to derive equations in terms of dimensionless parameters suggested by Barnett. The equations which are for three different flow regimes for each rod geometry (even or odd) were found to predict burnout data with maximum RMS deviation being 3.8%. (author). 11 figs., 3 tabs., 15 refs.
Biosynthesis of hemoglobin and some of its electrophoretic fractions in red cells of peripheral blood and spleen of irradiated (650 R) rats has been studied. Hemoglobin synthesis is found to be most drastically inhibited in the first and second fractions on the first and eighth days after irradiation and in the fifth and sixth fractions on the eighth day (less expressed). The synthesis is restored on the twelfth day, the process under study proceeding more slowly in the above-mentioned fractions than in others. In the course of radiation sickness, the biosynthesis of certain hemoglobin fractions varies differently in the hemoglobin-synthesizing cells of peripheral blood than in the cells of spleenic erythroid series.
The ion nitriding treatment is a process widely used in steel alloys to improve the material's properties; such as surface hardness, resistance to wear, fatigue life and resistance to corrosion. But geometric changes in the components can produce during the nitriding process different effects on the behavior of the plasma, such as local variations in the electric field, an empty cathode effect, etc. These in turn can affect among other factors the local temperature and therefore the kinetics of the process, generating variations in the compound layer thicknesses and zone of diffusion, and micro-hardness profile. These heterogeneities limit the effectiveness of the plasma nitriding process, where control and duplication of the surface modification are most important. This work aims to study the effect of the geometry of the pieces treated with ionic nitriding, especially the effect of the orifices. An understanding of the operating mechanisms is ...
Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti{sub 2}N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 {mu}m{sup 2}/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to ...
Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti_2N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 #mu#m"2/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high ...
The plasma protein binding of phenytoin was investigated in 100 epileptic patients, using equilibrium dialysis at 37 degrees C. The unbound fractions of phenytoin in plasma formed a skewed distribution,...Full Text Available
Plasma nitriding as a diffusion process is the oldest plasma-assisted process for the surface treatment of metals. Although the use of this process in industry is already well developed and established there are still several scientific questions in the basic understanding of the process and consequently some problems and limits concerning its upscaling for industrial use. Therefore it is necessary to get reproducible results for different geometries of workpieces and for different workload sizes. Correlations between different plasma and treatment parameters, especially in big plants, have to be considered. To understand the process handling using some simple but impressive models the difficulties of treating single parts or mixed workloads are explained. For profitable applications of plasma nitriding plants, some guidelines for the use and selection of a suitable process and a device are given. By ...
A new miniature high-frequency (HF) plasma source intended for bio-medical applications is studied using nitrogen/oxygen mixture at atmospheric pressure. This plasma source can be used as an element of a plasma source array for applications in dermatology and surgery. Nitric oxide and ozone which are produced in this plasma source are well-known agents for proliferation of the cells, inhalation therapy for newborn infants, disinfection of wounds and blood ozonation. Using optical emission spectroscopy, microphotography and numerical simulation, the gas temperature in the active plasma region and plasma parameters (electron density and electron distribution function) are determined for varied nitrogen/oxygen flows. The influence of the gas flows on the plasma conditions is studied. Ozone and nitric oxide concentrations in the effluent of the ...
Fasting plasma concentrations of magnesium were measured by neutron activation analysis in 30 non-diabetics and 87 diabetics (55 non-insulin-treated, 32 insulin treated). Plasma concentrations of magnesium...Full Text Available
Prof. Kodi Husimi was the director of the Institute of Plasma Physics of Nagoya University during 12 years from the beginning of the institute establishment in 1961. His main contribution on promotion of plasma physics and fusion research at the Institute is summarized. (author)
1 The plasma protein binding of theophylline was determined after addition of [14C]-theophylline (15 micrograms/ml) to plasma from 24 healthy drug-free volunteers and equilibrium dialysis for 2 h at...Full Text Available
High power and particle deposition on target materials are encountered in many applications including magnetic and inertial fusion devices, nuclear and high energy physics applications, and laser and discharge produced plasma devices. Surface and structural damage to plasma-facing components due to the frequent loss of plasma confinement remains a serious problem for the Tokamak reactor concept. The deposited plasma energy causes significant surface erosion, possible structural failure, and frequent plasma contamination.
The bibliography contains citations concerning plasma immersion ion implantation (PIII) and equipment. PIII is a new technique to implant plasma ions into materials for surface modification and treatment. Topics include plasma nitriding, semiconductor doping, ion energy distribution, ion dose, pulsed plasma, metal plasma, and defect passivation. References also review applications in semiconductor device and integrated circuit manufacture, silicon material fabrication, aerospace bearings, carbon coatings on metals, and ceramic coatings. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)
In the present paper we propose a model of physical phenomena behind the front face of the electrodes in an impulse plasma accelerator. The model is based on the results of recent experimental observations and measurements. It correlates plasma dynamics with mechanism of phenomena in a column of pinching plasma. On the contrary to the previous model the current one suggests the series of relatively short pulses of metallic ions from the erosion of electrode material. Till now the pinch was treated rather as a nearly continuous source of metallic plasma, feeding the process with ions from the erosion of electrode material. (author)
We studied the optimum plasma conditions that are required for efficient high-order harmonic generation in platinum plume. Harmonics up to the 49th order (?=16.32 nm) are analyzed under various conditions of laser-plasma interaction. Time-resolved ultraviolet spectra of platinum plasma at both optimum and nonoptimum conditions of harmonic generation are presented. We calculated the ionization states of the plasma, free electron density, and singly charged ion density at different prepulse intensities and compared them with experimental results.
The influence of motion of ions and electron temperature on nonlinear one-dimensional plasma waves with velocity close to the speed of light in vacuum investigated. It is shown that although the wavebreaking field weakly depends on mass of ions, the nonlinear relativistic wavelength essentially changes. The nonlinearity leads to the increase of the strong plasma wavelength, while the motion of ions leads to the decrease of the wavelength. Both hydrodynamic approach and kinetic one, based on Vlasov-Poisson equations, are used to investigate the relativistic strong plasma waves in a warm plasma. The existence of relativistic solitons in a thermal plasma is predicted.
In terms of the kinetic theory of the interaction between the high-power short-time laser pulses with plasma based on the propagator plotting for the plasma particle distribution functions one studied the generation of the hot electrons and of the fast ions as the relativistic femtosecond laser pulses travelled through the supercritical density plasma. One performed calculations based on the various values of the laser pulse intensity, types of the multiple-charged ions, the plasma inhomogeneity degree. One studied the acceleration mechanisms both of the plasma electrons and ions
The paper presents experimental investigations of main features of plasma surface interaction and energy transfer to the material surface in dependence on plasma heat loads. The experiments were performed with QSPA repetitive plasma pulses of the duration of 0.25 ms and the energy density up to 2.5 MJ/m2. Surface morphology of the targets exposed to QSPA plasma screams is analyzed. Relative contribution of the Lorentz force and plasma pressure gradient to the resulting surface profile is discussed. development of cracking on the tungsten surface and swelling of the surface are found to be in strong dependence on initial temperature of the target.
Observations show the ubiquitous presence of propagating magnetohydrodynamic (MHD) kink waves in the solar atmosphere. Waves and flows are often observed simultaneously. Due to plasma inhomogeneity in the perpendicular direction to the magnetic field, kink waves are spatially damped by resonant absorption. The presence of flow may affect the wave spatial damping. Here, we investigate the effect of longitudinal background flow on the propagation and spatial damping of resonant kink waves in transversely nonuniform magnetic flux tubes. We combine approximate analytical theory with numerical investigation. The analytical theory uses the thin tube (TT) and thin boundary (TB) approximations to obtain expressions for the wavelength and the damping length. Numerically, we verify the previously obtained analytical expressions by means of the full solution of the resistive MHD eigenvalue problem beyond the TT and TB approximations. ...
This report summarizes the progress and accomplishments in accelerator atomic physics research supported by DOE grant DE-FG02-87ER13778 from February 16, 1990 through February 15, 1993. This work involves the experimental investigation of atomic interactions in collisions of charged projectiles with neutral targets or electrons, with particular emphasis on two-electron interactions and electron-correlation effects. The processes studied are of interest both from fundamental and applied points of view. In the latter case, results are obtained which are relevant to the understanding of laboratory and astrophysical plasmas, highly-excited (Rydberg) and continuum states of atoms and ions, atomic structure effects, the interaction of ions with surfaces, and the development of heavy-ion storage-rings. The results obtained have provided the basis for several M.A. thesis projects at Western Michigan and several Ph.D. dissertation ...
It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)
A nonneutral /sup 7/Li/sup +/ ion plasma is described in which ion Langmuir waves are observed for the first time. The properties of these waves near the Brillouin density limit are investigated.
Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.
The DITE (Divertor Injection Tokamak Experiment) program has been undertaken to demonstrate the feasibility of impurity control by the use of a diverter in an injection-heated toroidal plasma configuration. Rather than behaving in accordance with neoclassical toroidal containment theory, the plasma is subject to various instabilities, particularly the resistive fluid MHD types, follows the empirical scaling of energy confinement time with plasma parameters observed in other plasma devices. DITE experiments have, however, extended the range of current and density. Impurities arising from plasma interactions with the vacuum vessel surface are controlled by the bundle divertor, which diverts a portion of plasma and power in the plasma scrape-off layer into a separate target chamber where impurities can be removed. Auxiliary ...
The properties of polycrystalline (Ti, Al)N coatings deposited on non-nitrided, classically plasma-nitrided and low pressure plasma-nitrided AISI H11 steel samples were investigated. The plasma deposition and low pressure plasma nitriding were performed in a Z700-LH magnetron sputter ion plating unit, while a separate unit was used for plasma nitriding of specimens at a pressure of several millibars. The (Ti, Al)N coating was deposited onto all the samples using the same equipment as for the plasma deposition and low pressure plasma nitriding. For the characterization of the composite structures, the following methods were used: scratch test, X-ray diffraction analysis, scanning electron microscopy, scanning tunnelling microscopy and microhardness testing. It was found that plasma nitriding prior to coating deposition ...
A cross-flow atmospheric plasma jet with distilled water or analyte solution nebulization has been investigated. The plasma gas flows perpendicularly to the RF powered electrode (11.21 MHz) and a grounded electrode was added for plasma stabilization. The working parameters of the plasma generator can be controlled in order to maximize either the plasma power (75 W) or the voltage on the RF powered electrode (plasma power, 40 W). The plasma gas, pure argon (0.4 l min-1) or a mixture of argon (0.3-0.4 l min-1) and helium (0-0.2 l min-1), was also used for liquid nebulization. Optical emission of the plasma, collected in the normal viewing mode, was used for plasma diagnostics and for evaluating its excitation capabilities. The influence of helium content in the mixed-gas plasma on ...
This report summarizes the results and activities funded by this three-year award. The principal goal of this project was to determine the thermal conductivity in clusters of galaxies. Intracluster plasmas possess chaotic magnetic fields. Since charged particles are constrained to move primarily along magnetic field lines, the topology of intracluster magnetic fields slows particle diffusion relative to the non-magnetized case, thereby reducing the thermal conductivity. Our first approach to this problem was to employ the static-magnetic-field approximation. In reality, intracluster magnetic field lines are constantly moving, since they are advected by turbulent intracluster motions. The turbulent velocities, however, are much smaller than the rapid speeds of thermal electrons, which make the dominant contribution to the thermal conductivity. In the static-field approximation, one neglects turbulent motions of field lines, and calculates the diffusion coefficient ...
To evaluate the radiological patterns of vascular invasion in peripheral cholangiocarcinomas. Hepatic arteriography and portography in 20 cases with cholangiocarcinoma including 12 cases with angiographic CT were retrospectively analyzed. The arteriography showed no arterioportal shunt, hypertrophy of tumor vessel, or tumor staining extending to central portion of the mass in all cases. However, doughnut shaped peripheral tumor staining was seen until late hepatogram phase in 12 cases and compensatory hyperperfusion around the mass was seen in six cases (eight cases if include arterial CT). Encasement of tumor vessel was seen in 12 cases, and hypertrophy of feeding vessel in nine cases. On portography, the filling defect on segmental portal branch could be demonstrated only in 11 cases. Shape of the portal defect was tapered narrowing in six cases, abrupt narrowing in two cases but intraluminal nodular filling defect was not seen. Remaining ...
Objective: To investigate transcutaneous oximetry as parameter of the microcirculation is correlated to ankle-brachial-index as parameter of the macrocirculation after peripheral angioplasty procedures. Design: Prospective study. Materials and methods: 60 patients suffering from intermittent claudication were scheduled for angioplasty treatment. 45 patients were considered as eligible for angioplasty after angiographic evaluation, 15 patients underwent angiography only. Transcutaneous oximetry measurements were performed before the procedure, at the end of intervention, 24 h as well as 2 and 4 weeks after percutaneous transluminal angioplasty. Ankle-brachial-indices were obtained before intervention, 24 h as well as 2 and 4 weeks later. Results: Ankle-brachial-indices increased significantly at 24 h after angioplasty in patients being treated with angioplasty. Transcutaneous oximetry values dropped significantly at the end of the procedure and ...
We have investigated the hemostatic properties of the free-electron laser (FEL) and compared these properties to the most commonly used commercial lasers in neurosurgery, CO_2 and Nd:YAG, using an acute canine model. Arterial and venous vessels, of varying diameters from 0.1 to 1.0 mm, were divided with all three lasers. Analysis of five wavelengths of the FEL (3.0, 4.5, 6.1, 6.45, and 7.7 microns) resulted in bleeding without evidence of significant coagulation, regardless of whether the vessel was an artery or vein. Hemorrhage from vessels less than 0.4 mm diameter was subsequently easily controlled with Gelfoam registered (topical hemostatic agent) alone, whereas larger vessels required bipolar electrocautery. No significant charring, or contraction of the surrounding parenchyma was noted with any of the wavelengths chosen from FEL source. The CO_2 laser, in continuous mode, easily coagulated vessels with diameters of 4 mm and less, while larger vessels displayed significant ...
A new multipellet long-pulse plasma fueling system is in operation on JET. In the initial experimental phase, a variety of plasma density profile shapes have been produced with peak to average values ranging up to 2.5 and peak plasma density up to 1.2 )times) 10/sup 20/m/sup )minus/3). 7 refs., 4 figs
The analysis of plasma density oscillations and ExB rotation of U-3M torsatron plasma was performed by UHR correlation reflectometry during the transport barrier formation. The connections between these characteristics and the phenomenon of inner and edge transport barrier formation were determined experimentally at the different values of HF power and plasma density.
Carbon fibre composite (CFC) was irradiated by hot plasma streams at plasma gun facility MK-200UG. The CFC targets were tested by plasma loads relevant to Edge Localized Modes (ELM) and mitigated disruptions in ITER. Onset condition of CFC evaporation and properties of evaporated carbon were studied by use of infrared pyrometry and visible spectroscopy.
The beams in electron linear colliders can be converted to nearly monochromatic photon beams by means of Compton backscattering of laser photons. The electron beams must then be diverted from the interaction point by some means, the best of which seems to be a plasma lens. This paper describes the constraints on the plasma lens in this application and shows how the ablation of solid hydrogen pellets might be able to produce plasmas to satisfy these constraints. ((orig.)).
Comparison of plasma density increase was carried out in outer and inner channels of the interferometer in T-11M tokamak. There were two cases of gas puffing: by outer valve or upper one. Amplitude of difference of the plasma density increase consisted of 9% near the outer valve. Perturbation of the electric potential e?1/Te can have similar value. This perturbation can lead to appearance of the additional losses.
Low pressure plasmas have some promising advantages for nitriding The separation of plasma generation from the workpiece overcomes several of the major drawbacks of conventional plasma nitriding and also allows independent control of ion flux and energy This opens the possibility of nitriding at lower temperatures so that the process can be extended to a wider range of materials and applications. Copyright (1999) Materials Australia
One of several methods to build YSZ electrolyte of SOFC is plasma spraying. This system heats particle to a melting point and then pushing them into target and forming a deposition. This paper presents heating studies of YSZ particle in plasma jet. By simple model it is shown that the required time such those YSZ particle with grain size of 50 ?m to be melt is around 12 x 10-4 second. (author)
9 9 simulated Purex waste oxides was investigated as a function of Na/sub 2/O, CaO and P/sub 2/O/sub 5/ content. All compositions lost some sulfate at 50 to 100 deg C above the softening point. In generai the volatility decreased with increase of either Na/ sub 2/O or CaO relative to P/sub 2/O/sub 5/, but no simple correlation Was indicated. Softening temperatures were lowered by inc ease in Na/sub 2/O vs CaO. Ceramic solids were obtained but no true glasses. Attempts to produce glasses by addition of varying combinations of Al/sub 2/O/sub 3/, PbO, BaO, and B/sub 2/O/ sub 3/ to simulated Pure x waste plus phosphite were unsuccessful. The use of 0.005 M Na/sub 2/C/O/sub 3/ to precipitate calcium from wastes containing up to 3 ppm of phosphate was demonstrated in four pilot plant runs and produced a decrease in the hardness of the waste leaving the clarifier. An inadvertent Sr/ sup 90/ and Cs/sup 137/ breakthrough occurred during one ...
Low pressure silane plasmas are known for their ability to synthesize silicon nanoparticles via gas phase nucleation. While in the past this particle formation has often been considered from the viewpoint of a contamination problem in semiconductor processing, we here describe a silane low pressure plasma that enables the synthesis of highly oriented, cubic-shaped silicon nanocrystals with a rather monodisperse size distribution. These silicon nanocubes have successfully been used in the manufacture of single nanoparticle vertical transistors. We discuss the advantages of this new paradigm of building nanoelectronic devices. The plasma synthesis process is characterized in more detail than in prior work. The particle nucleation, growth and shape evolution are studied. Results indicate that the process provides two spatially distinct zones: a diffuse plasma for particle growth and a constricted ...
The possibility of surface modification of high-speed steel cutting tool by means of vacuum-plasma treatment including ion nitriding in gas plasma followed by the deposition of wear resistant (Ti, Al)N coatings in metal-gas plasma of a vacuum arc discharge is studied. The regularities of nitrided layer formation and the structure of these layers under various operation conditions of cutting tool are investigated. Optimum conditions of vacuum-plasma treatment providing the best wear resistance of cutting are determined
Thomson scattering is the process in which a low-energy photon scatters from a free electron. When a laser pulse propagates through a plasma, the spectrum of the scattered light due to the Thomson scattering is proportional to the power spectrum of the electron density fluctuations, i.e., dynamic form factor, from which various plasma parameters can be inferred, such as electron temperature and plasma flow velocity. After years of development. Thomson scattering has now become a powerful diagnostic tool of plasma physics. (authors)
The paper presents results of experimental research on the interaction of a pulsed plasma-ion stream with a tungsten (W) target. The pulsed hydrogen plasma was produced within the RPI-IBIS (Multi-Rod Plasma Injector) facility at IPJ in Swierk. Measurements were carried out by means of optical spectroscopy and corpuscular diagnostic techniques. For experiments with the W-target the operational conditions (so-called PID mode) were chosen when a clean hydrogen plasma stream was generated. Attention was paid to the identification of WI and WII spectral lines.
An experiment of a plasma torch on a production foundry cupola is reported. The test runs were conducted on a hot blast cupola, the blast temperature in the absence of plasma being 400 C. With the torch, the temperature of the blast was increased to 1000 C. The experiment was conducted for the manufacture of car engines with a 2.5 MW transportable plasma system. The cupola was boosted with a 4 MW torch and results included an increase in production of 45 percent, a decrease in coke rate and no more new iron in the loads. The plasma torch and hot air cupola furnace are described.
Currentless plasma in Uragan-3M (U-3M) is produced and heated by absorption of RF power in the region of Alfven waves (AW). The process of plasma heating was explained in (2) as a result of Cherenkov absorption of energy of the fast (EM) and slow (kinetic Alfven) waves by electrons and turbulent ion heating due to excitation of short wave ion Bernstein waves (IBW). In this report we present results of studies of plasma density fluctuations showing existence of a narrow bands near the frequencies of ? ? n?ci (n=1,2,3).
Electrostatic plasma simulation code for 2D rectangular geometry is presented. Main distinguishing feature of the code is its orientation on the beam-plasma interaction. The code and its graphical interface were developed using MATLAB programming language. Simulation results of inhomogeneous plasma interaction with modulated electron beams of different width are compared. In case of wide beam the front of Langmuir waves generated in point of local plasma resonance is planar and in case of thin beam (or ribbon beam) the front has approximately half-circular form.
An offshore drilling rig is described for use in drilling into a formation below a body of water comprising a barge hull having a drilling slot extending inwardly from the peripheral boundary of the barge hull, means for supporting the barge hull in a position above the water, a cantilever structure mounted on the barge hull and movable horizontally with respect to such barge hull, the cantilever structure being so located relative to the drilling slot as to be movable horizontally into a position in vertical alignment with the drilling slot, a derrick and drilling machinery mounted to the cantilever structure and movable into a position above the drilling slot whereby well drilling operations may be conducted through the drilling slot, the cantilever structure also being movable horizontally to a position which locates the derrick and the drilling machinery outboard of the peripheral boundary of the barge hull, whereby a drilling operations ...
The nanocrystallization process of amorphous Fe_7_3_._5Si_1_3_._5B_9Nb_3Cu_1 was investigated by active screen plasma nitriding (ASPN) treatment at temperatures ranging from 410 "oC to 560 "oC for 3 h in two gas mixtures of 75% N_2-25% H_2 and 25% N_2-75% H_2 at 5 mbar atmosphere. The amorphous ribbons were then annealed under vacuum at the same time and temperatures mentioned above. The structure of the samples was analyzed using various techniques such as X-ray diffraction (XRD), atomic force microscopy (AFM) and differential scanning calorimetry (DSC). Microhardness measurements, electrical resistivity and Vibrating Sample Magnetometer (VSM) were used to study mechanical, electrical and magnetic properties of the samples, respectively. It was observed that the ASPN treatment leads to finer grain size and higher crystalline volume fraction and modifies the structural features of Fe(Si) phase. The Fe(Si) lattice parameter for the nitrided samples decreased up to ...
In support of the efforts to apply ceramics in advanced heat engines, a study was made of the sliding performance of ceramics at the ring/cylinder interface of low heat rejection engines. The objective was to understand the basic mechanisms controlling the wear of candidate ceramics and thereby identify means for applying these ceramics effectively. Attempts to operate three different zirconias, silicon carbide, silicon nitride, and several plasma-sprayed ceramic coatings without lubrication were unsuccessful because of high friction and high wear rates. Experiments using a polyalphaolefin lubricant at temperatures to 260 C identified several combinations having wear rates in the general range likely to be acceptable for engines. Plasma-sprayed coatings of chromium oxide and hypersonic powder flame sprayed coatings of cobalt-bonded tungsten carbide performed particularly well as ring coatings. Similar performance was ...
The effects of a daily 3-g supplement of betaine on kinetic aspects of L-[2H3-methyl-1-13C]methionine (MET) metabolism in healthy young adult men were explored. Four groups of four subjects each were given a control diet, based on an L-amino acid mixture supplying 29.5 and 21.9 mg.kg-1.d-1 of L-methionine and L-cystine for 4 d before the tracer study, conducted on day 5 during the fed state. Two groups received the control diet and two groups received the betaine supplement. Tracer was given intravenously (iv) or orally. The transmethylation rate of MET (TM), homocysteine remethylation (RM), and oxidation of methionine were estimated from plasma methionine labeling and 13C enrichment of expired air. RM tended to increase (P = 0.14) but the TM and methionine oxidation were significantly (P less than 0.05) higher after betaine supplementation when estimated with the oral tracer. No differences were detected with the intravenous tracer. Methionine concentration in ...
The involvement of dorsal root ganglia was studied in an in vivo model of experimental rabies virus infection using the challenge virus standard (CVS-11) strain. Dorsal root ganglia neurons infected with CVS in vitro show prolonged survival and few morphological changes, and are commonly used to study the infection. It has been established that after peripheral inoculation of mice with CVS the brain and spinal cord show relatively few neurodegenerative changes, but detailed studies of pathological changes in dorsal root ganglia have not previously been performed in this in vivo experimental model. In this study, adult ICR mice were inoculated in the right hindlimb footpad with CVS. Spinal cords and dorsal root ganglia were evaluated at serial time points for histopathological and ultrastru...
Ex vivo expanded peripheral blood progenitor cells (PBPC) have been shown to provide rapid neutrophil engraftment, and in some patients, to eliminate neutropenia after transplantation to support high-dose chemotherapy. However, the effect of expansion culture on stem cell content and potential loss of stem cells caused by induction of differentiation remains a concern. We have transplanted 21 patients with breast cancer with expanded autologous PBPC, with 11 patients receiving expanded PBPC as their sole hematopoietic cell source. In these studies, the CD34+ cells were selected and cultured for 10 days in defined media containing 100 ng/mL each of recombinant human stem cell factor (rhSCF), recombinant human granulocyte colony stimulating factor (rhG-CSF), and recombinant human megakaryocy...
A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin.
Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).
Amphiphysin is a protein concentrated in neuronal synapses and peripherally associated with neurotransmitter vesicles. It is expressed in many neurons of the central and peripheral nervous systems, in the adrenal medulla, in the anterior and posterior pituitary, in cell lines of the endocrine pancreas, and in spermatocytes. Its subcellular localization and tissue distribution indicate a potential involvement in mechanisms of regulated exocytosis. A role in the dynamic organization of the membrane-associated cytoskeleton is suggested by structural homology to the products of two yeast genes, RVS161 and RVS167, whose mutation results in an abnormal actin distribution, disturbs budding morphology, and impairs cell entry into stationary phase. Limited stretches of sequence similarity, including an SH3 domain, are also shared with other actin-binding proteins. Amphiphysin is the dominant autoantigen in paraneoplastic Stiff-Man syndrome, a ...
The most striking achievement in magnetic fusion experiments during last few years was the discovery of plasma detachment from material targets, a much needed effect for plasmas with high power fusion parameters. Due to the very low heat loads on the targets observed in these regimes and potentially low erosion of the targets, detached regimes look attractive from the International Thermonuclear Experimental Reactor (ITER) design point of view. Thus the author has experimental proof for the possibility for a co-existence of fusion relevant hot plasma in the core and a low temperature partly ionized plasma at the edge of magnetic fusion device. Although somewhat similar behavior of edge plasma was considered theoretically even before plasma detachment was found experimentally, it was not clear in the beginning how these theoretical and experimental findings would ...
The paper presents the investigations of plasma streams generated by pulsed plasma gun 'Prosvet' operated with different gases: krypton (m=84) and helium (m=4). Contour parameters of working gas spectral lines (full intensities and half-widths) are used for determination of spatial distributions of the electron density and temperature. Temporal distributions of the spectral lines intensities (both neutrals and ions of working gas), impurity spectral lines and continuum intensities are analyzed. Plasma stream velocity was estimated by time-of-flight method between two monochromators (MUM) connected with photo-multiplier. longitudinal distributions of the plasma pressure for different time moments and varied distances from the accelerator output have been used for investigation of the plasma stream dynamics and study the plasma compression in the focus region for ...
In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by ...
In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by ...
The dispersion of more than 20 vol pct submicrometer ceramic particles within a metallic matrix and the deposition of such a cermet to form a thick and tough coating presents problems. Most of the coating techniques have failed in attempting to homogeneously disperse very fine and hard particles in large amounts while avoiding their decomposition or reaction with the metal matrix during the deposition process. A simple and efficient method has been developed for producing ceramic-containing composite coatings. It consists in synthesizing cermet-based materials and in depositing them by a rapid solidification process, such as thermal spraying. Boride- and carbide-based materials have been successfully obtained by plasma spraying reactive powders comprising the basic reagents. These materials, with a microstructure of submicrometer ceramic particles dispersed in a metallic matrix, exhibit good wear-resistant properties (abrasion and sliding ...
By improving the currently used lactoperoxidase method, we were able to obtain radioiodinated chicken luteinizing hormone (LH) that shows high specific binding and low nonspecific binding to a crude plasma membrane fraction of testicular cells of the domestic fowl and the Japanese quail, and to the ovarian granulosa cells of the Japanese quail. The change we made from the original method consisted of (1) using chicken LH for radioiodination that was not only highly purified but also retained a high receptor binding potency; (2) controlling the level of incorporation of radioiodine into chicken LH molecules by employing a short reaction time and low temperature; and (3) fractionating radioiodinated chicken LH further by gel filtration using high-performance liquid chromatography. Specific radioactivity of the final {sup 125}I-labeled chicken LH preparation was 14 microCi/micrograms. When specific binding was 12-16%, nonspecific binding was as ...
To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution function may be obtained from these data. A superheterodyne receiver at 60--90 GHz has ...
We present the general properties of the far-ultraviolet (FUV; 1370-1720A) continuum background over most of the sky, obtained with the Spectroscopy of Plasma Evolution from Astrophysical Radiation instrument (SPEAR, also known as FIMS), flown aboard the STSAT-1 satellite mission. We find that the diffuse FUV continuum intensity is well correlated with N_{HI}, 100 $\\mu$m, and H-alpha intensities but anti-correlated with soft X-ray. The strongest correlation is with the H-alpha emission, and the correlation of the diffuse background with the direct stellar flux is weaker than the correlation with other parameters. The continuum spectra are relatively flat. However, a weak softening of the FUV spectra toward some sight lines, mostly at high Galactic latitudes, is found not only in direct-stellar but also in diffuse background spectra. The diffuse background is relatively softer that the direct stellar spectrum. We also find that the diffuse FUV ...
In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P{sup +}/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B{sup +} and BF{sub 2}{sup +} ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF{sub 3} as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit ...
In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P"+/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B"+ and BF_2"+ ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF_3 as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit coming from PLAD ...
The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled beta 2-microglobulin ...
Hydrolysis kinetics of the lead silicate glass (LSG) with 40 mol% PbO in 0.5 N HNO_3 aqueous acid solution was investigated. The surface morphology and the gel layer thickness were studied by scanning electron microscopy (SEM) micrographs. Energy dispersive X-ray spectroscopy (EDS) and inductively coupled plasma spectroscopy (ICP) were used to determine the composition of the gel layer and the aqueous solution, respectively. The silicon content of the dissolution products was determined by using weight-loss data and compositions of the gel layer and the solution. The kinetic parameters were determined using the shrinking-core-model (SCM) for rate controlling step. The activation energy obtained for hydrolysis reaction was Q_c_h_e = 56.07 kJ/mole. The diffusion coefficient of the Pb ions from the gel layer was determined by using its concentration in solution and in LSG. The shrinkage of the sample and the gel layer thickness during dissolution ...
Energy confinement in W7-AS has been analyzed in terms of dimensionally exact form free functions employing Bayesian probability theory. The confinement function was set up as a linear combination of dimensionally exact power law terms as already proposed very early by Connor and Taylor. Generation of this expansion basis is dictated by the basic plasma model which one assumes. Based upon data accumulated in W7-AS, which contains the energy content for a wide variety of variable settings, predictions for single variable scans are made. The scaling functions for density and power scans, respectively, are in quantitative agreement with data collected in W7-AS. The result of a single variable scan is therefore already hidden in the data obtained for arbitrary variable choices and can be extracted from the latter by a proper data analysis. Furthermore, the optimal model for the description of the global transport in W7-AS is identified as the ...
The Electromagnetic Fluctuations (EMF) diagnostic will be used to monitor ion fluctuations which could be unstable in MFTF-B. Each probe assembly includes a high impedance electrostatic probe to measure potential fluctuations, and a group of nested, single turn loops to measure magnetic fluctuations in three directions. Eventually, more probes and loops will be added to each probe assembly for making more detailed measurements. The sensors must lie physically close to the plasma edge and are radially positionable. Also, probes at separate axial locations can be positioned to connect along the same magnetic field line. These probes are similar in concept to the rf probes used on TMX, but the high thermal load for 30-second shots on MFTF-B requires a water-cooled design along with temperature monitors. Each signal channel has a bandwidth of .001 to 150 MHz and is monitored by up to four different data channels which obtain amplitude and frequency ...
Chromium containing amorphous hydrogenated carbon films (a-C : H/Cr) have been prepared by simultaneous rf plasma activated chemical vapour deposition of methane and magnetron sputtering of a chromium target. During deposition the substrates were heated (up to 300C) and DC biased (-200 and -600 V) in order to obtain films with high chemical stability. Constant temperature tests were performed at 250C in air with coatings deposited on silicon substrates. The degradation of the coatings was monitored by Raman spectroscopy and reflectance and transmission measurements. The main degradation mechanisms are discussed and the relevant parameters which improve the durability of the coatings are presented. Furthermore, the durability of solar selective, multilayered coatings which were deposited on copper sheets was investigated. Based on accelerated aging tests at different temperature loads in air (at 220C, 250C and 300C) and in a humid environment ...
The aim of the present study was to test a mathematical model of the biochemical processes in the parathyroid glands responsible for the secretion of parathyroid hormone resulting from extracellular calcium reduction. A double exponential curve described the parathyroid hormone secretion induced by rapid lowering of blood-ionized calcium in humans with normal as well as abnormal parathyroid tissue. Our data show that it was possible to establish a simple mathematical model of the parathyroid hormone response to blood-ionized calcium lowering, sufficient to fit experimental data obtained from patients with abnormal and normal parathyroid tissue. The fitted parameters showed no significant differences between patients with insulin-dependent diabetes mellitus and controls. In primary hyperparathyroidism, the parathyroid hormone production and steady-state transport across the cell membrane were increased, probably due to the larger amount of parathyroid tissue in ...
The properties of AlN make this material very attractive for optical, electronic, and tribological application. Also, if the AlN could be formed on the Al surface to enhance its surface properties, Al could be applied for the lightening of machine parts. However, a dense oxide film exists on the surface of Al, which prevents the formation of the Al nitride even during plasma nitriding and plasma coating process. In this study, plasma nitriding has been tried to form an AlN layer on Al after the surface activation processes. During the plasma nitriding, the density of the nitrogen ions was amplified by means of controlling the power of the Al substrates. The film thickness, microstructural features and the mechanical properties such as hardness and wear properties of the AlN layer were examined as a function of the process parameters of pretreatment and plasma nitriding
The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.
The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition {ital k}{sub {ital p}}{sigma}{sub {ital x}}{approx_gt}1, and not {ital k}{sub {ital p}}{sigma}{sub {ital y}}{approx_gt}1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for {gamma}{gamma} colliders is discussed.{copyright}{ital American Institute of Physics.}
The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition k_p#sigma#_x approx-gt 1, and not k_p#sigma#_y approx-gt 1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for #gamma##gamma# colliders is discussed.copyright American Institute of Physics.
In this paper a novel method is presented, based on the use of plasma processing, to suppress the transient enhanced diffusion of boron implanted in silicon. We found for silicon samples processed with plasma and subsequently boron implanted that the anomalous diffusion of the dopant atoms at the beginning of the annealing process is almost completely suppressed. This phenomenon is interpreted in terms of capture of the ion beam generated interstitials by the dislocations induced by the plasma processing. At room temperature the dislocations are observed to grow in size after the boron implant, attesting their efficiency as trapping centres for interstitials. Moreover, varying the plasma process conditions we can establish a general relation between the presence of the trapping centres induced by the plasma processing and the suppression of the transient diffusion.
It is a traditional method to diagnose electron-cyclotron-resonance (ECR) plasma source, using a single probe to measure the current-voltage curve of the plasma, based on which and theoretic formula the plasma density can be computed. The article adopts a Langmuir probe having a role of emission electrons to measure two different current-voltage curves with and without emission. It is ease to get the plasma potential via the inflexion of the two curves and compute directly various physical quantities by the assistant computer, such as electron temperature, electron/ion density, plasma potential etc. The deviation is about percent 1.8 between the measurement results by traditional and the new method, but the latter has higher efficiency. (authors)
A new method of plasma treatment for powder particles was investigated. A glass bottle horizontally held on a rotating system was used for the treatment. The outside of the bottle was covered by the grounded metal net, and the rod electrode was provided at the center of the bottle, which was connected to an ac high voltage source. Powder particles were placed in the bottle with stainless steel beads of large diameter and the plasma was generated between two electrodes and while the bottle was rotating. Using this system, powder particles were uniformly plasma-treated without coagulation. After 40 seconds treatment with plasma of 0.55 W in Ar gas, the charge to mass ratio for polyethylene powder particles having 160 {mu}m mean diameter generated by stainless before treatment. (author)
This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in ...
A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are ...
When a plasma becomes contaminated by foreign particles, generically referred to as dust, the result is called a dusty plasma. At the present time there is a great deal of interest in dusty plasmas because of their roles in terrestrial and extra-terrestrial processes - semiconductor processing, high temperature fusion experiments, stellar formation and the rings of Saturn. This thesis is concerned with the role of dust in processing type plasmas. In the following experiments, artificial dust is introduced into a parallel electrode plasma chamber. Ions and electrons in the plasma charge the dust particles and they become suspended in the plasma due to the balancing of electric and gravitational forces. By illuminating the suspended dust with laser light and using an extremely high speed camera fitted with a macro lens to look at the scattered ...
By means of an audio frequency plasma polymerisation ultra-thin gradient plasma polymer layers were deposited on zinc and zinc-coated iron. The aim was to generate an interfacial polymeric layer which bonds to an oxidised metal as well as to a subsequently applied organic coating and acts as an interfacial barrier layer for ions and water. Surface modifications were done in an in situ plasma cell with infrared reflection absorption spectroscopy (IRRAS). The zinc surface was first activated by an oxygen plasma to provide a freshly oxidised and contamination free oxide surface. The intermediate stages of the surface reactions could be revealed. Carbon dioxide molecules as oxidation products adsorbed on the growing zinc oxide and were desorbed at a later stage. An organosilicon plasma polymer was deposited directly on top of the oxide layer from a hexamethyldisilane (HMDS) ...
This article describes acoustic methods used in the in-service inspection of the dams and peripheral concrete structures of the Toktogul, Kurpsai, and Bratsk hydroelectric and pumped storage plants. The tests were conducted to assess the compression strength, elasticity, and tensile strength of the concretes. Comparative evaluations against drill core studies proved the acoustic methods to be sufficiently accurate in predicting aging behavior and loss of mechanical and physical integrity in the concretes.
The presence of a high number of activated T cells in the bloodstream and spontaneous proliferation of peripheral blood mononuclear cells in vitro are striking characteristics of human T-cell leukemia...Full Text Available
Two sets of experiments have been performed in sodium with two seven pin electrically heated bundles: the first with a nominal arrangement, the second with one dummy pin enlarged 20% in diameter in peripheral position. In this paper a rapid review of experimental results and theoretical works, related to the temperature distribution in these geometries, is presented together with a short description of the developed test section technology.
The right upper lung lobe of a 74 year old man was resected for a central tumour. Two primary cancers were found; a central small cell carcinoma and a peripheral squamous cell carcinoma. In addition,...Full Text Available
With collaboration between chemistry, X-ray crystallography, and molecular modeling, we designed and synthesized a series of novel piperazine sulfonamide BACE1 inhibitors. Iterative exploration of the non-prime side and S2prime sub-pocket of the enzyme culminated in identification of an analog that potently lowers peripheral Ab40 in transgenic mice with a single subcutaneous dose.
Transducin {alpha} subunits are members of a large family of G-proteins and play an important role in phototransduction in rod and cone photoreceptors. We report the localization of the human cone {alpha} transducin (GNAT2) gene using fluorescence in situ hybridization (FISH) on chromosome 1 in band p13. The recent assignment of a gene for Stargardt`s disease to the same chromosomal region by linkage analysis prompted us to investigate the possible role of GNAT2 in the pathogenesis of this disease. Stargardt`s disease is characterized by degeneration in late childhood or early adulthood of the macula of the retina, a region rich in cones. We screened patients with Stargardt`s disease, with or without peripheral cone involvement as monitored by the full-field ERG, for mutations in this gene. We investigated 66 unrelated patients including 22 with peripheral cone dysfunction for mutations in the coding region of the GNAT2 gene using polymerase ...
1. In order to determine the long-term influence of neonatal hypoxia on catecholaminergic activity in peripheral arterial chemoreceptors and brainstem noradrenergic cell groups (A1, A2, A5 and A6),...Full Text Available
This study evaluates the frequency and functions of immunocompetent T cells at the clonal level in solid human lung tissue versus peripheral blood. Enzymatic digestion of slices of histologically normal...Full Text Available
Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).
The rapidly activating and inactivating voltage-dependent outward K+ (Kv) current, IA, is widely expressed in central and peripheral neurons. IA has long been...Full Text Available
This study was conducted to determine the effects of sodium pentobarbital anesthesia on survival of the dog, leukocyte response, E. coli clearance from the peripheral blood and blood glucose concentration in the leukocytotic endotoxin pre-injected canine ...
Human Fas/Apo-1 is a cell-surface protein that mediates apoptosis upon ligation with Fas ligand. The gene lies on the long arm of chromosome 10, consists of nine exons, and spans more than 26 kb of...Full Text Available
Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).
Seventy male Wistar rats were the recipients of labeled small lymphocytes (1.5 X 10(7) each) collected from the peripheral blood of syngeneic donors. The migrating labeled lymphocytes were traced in...Full Text Available
The present invention relates to a method of recycling polymeric waste products into monomers and high value forms of carbon by pyrolytic conversion using an induction coupled RF plasma heated reactor.
Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.
The Ti-6Al-4V alloy was treated by inductively coupled rf plasma nitriding. The effects of plasma-processing time in the range of 5-35 min on the microstructure and the mechanical properties of the plasma-nitrided Ti-6Al-4V samples were studied. The plasma power input was adjusted at 450 W and pure N{sub 2} gas was introduced to establish a treatment pressure of 8.0-8.4 x 10{sup -2} mbar. The characteristics of the nitrided layers have been investigated by microhardness testing, surface roughness measurements, optical microscopy, and x-ray diffraction. The results show that the surface microhardness increases as the plasma-processing time increases to reach 2000 HV0.1 at a plasma-processing time of 35 min. A high nitriding rate of 2.81 {mu}m{sup 2} s{sup -1} at a plasma-processing time of 25 min was achieved. The formation of the hard phases ...
The Ti-6Al-4V alloy was treated by inductively coupled rf plasma nitriding. The effects of plasma-processing time in the range of 5-35 min on the microstructure and the mechanical properties of the plasma-nitrided Ti-6Al-4V samples were studied. The plasma power input was adjusted at 450 W and pure N_2 gas was introduced to establish a treatment pressure of 8.0-8.4 x 10"-"2 mbar. The characteristics of the nitrided layers have been investigated by microhardness testing, surface roughness measurements, optical microscopy, and x-ray diffraction. The results show that the surface microhardness increases as the plasma-processing time increases to reach 2000 HV0.1 at a plasma-processing time of 35 min. A high nitriding rate of 2.81 #mu#m"2 s"-"1 at a plasma-processing time of 25 min was achieved. The formation of the hard phases TiN, Ti_2N, and ...
A 750 J plasma coaxial accelerator is used to produce plasma using air at 0.2 torr pressure and 8 kv charging voltage. The discharge current and voltage traces showed that the total circuit inductance was about 1750 ?H. The experimental results showed that the plasma sheath reached the muzzle after 6 ?s with velocity equal to 4 cm/?s, after then it decreased, while the simulation model showed that the plasma sheath reaches the muzzle with velocity of 3 cm/?s and after one microsecond it increases to reach about 4 cm/?s after 12 ?s then it decreased. The plasma temperature measurements showed that the plasma sheath reached the muzzle with temperature of about 9 eV and increase to reach about 12 eV after 8.5 ?s then after it decrease. The simulation model showed that the plasma temperature at the muzzle is about 10.5 eV and continue to ...
The stability of prothrombin and factor VII was studied using accelerated degradation tests in three preparations of freeze-dried pooled normal plasmas. In a previous report (Brozović, Gurd,...Full Text Available
A number of studies have indicated that plasma membrane calcium ATPases (PMCAs) are expressed in the brain and spinal cord and could play important roles not only in the maintenance of cellular calcium...Full Text Available
The effects of homologous plasma HDL and VHDL fractions on established atherosclerotic lesions were studied in cholesterol-fed rabbits. Atherosclerosis was induced by feeding the animals a 0.5% cholesterol-rich...Full Text Available
Using plasma glutathione S-transferase measurements hepatocellular integrity was assessed in groups of hyperthyroid and hypothyroid patients before and after treatment. Ten of 14 hyperthyroid patients...Full Text Available
Plasma nitriding in glow discharge is a process of modifying surface properties of a material by which surface hardness, corrosion resistance, fatigue strength etc. of a material can be improved
1 Measuring total plasma levels of disopyramide (DP) and the main metabolite mono-N-dealkyldisopyramide (MND) in patients on maintenance therapy with DP has shown concentrations of MND comparable with...Full Text Available
A dielectric liquid having entrained bubbles of gas or vapor is subjected to an electric field applied between spaced electrodes (112, 116) which generates microdischarges (and thus plasma) within the bubbles, allowing modification of the properties of th...
The Plasma Science Committee (PLSC) of the National Research Council (NRC) is charged with monitoring the health of the field of plasma science in the United States and identifies and examines both broad and specific issues affecting the field. Regular meetings, teleconferences, briefings from agencies and the scientific community, the formation of study panels to prepare reports, and special symposia are among the mechanisms used by the PLSC to meet its charge. During July 1992, the PLSC sponsored a workshop on nonneutral plasmas in traps. Although no written report on the workshop results, was prepared for public distribution, a summary of highlights was provided to the OPST Subpanel on Nonneutral Plasmas. The PLSC also continued its follow-up briefings and discussions on the results of the results of the report Plasma Processing of materials. Scientific and Technological ...
The Plasma Science Committee (PLSC) of the National Research Council (NRC) is charged with monitoring the health of the field of plasma science in the United States and identifies and examines both broad and specific issues affecting the field. Regular meetings, teleconferences, briefings from agencies and the scientific community, the formation of study panels to prepare reports, and special symposia are among the mechanisms used by the PLSC to meet its charge. During July 1992, the PLSC sponsored a workshop on nonneutral plasmas in traps. Although no written report on the workshop results, was prepared for public distribution, a summary of highlights was provided to the OPST Subpanel on Nonneutral Plasmas. The PLSC also continued its follow-up briefings and discussions on the results of the results of the report Plasma Processing of materials. Scientific and Technological ...
Plasma exchange (PE) is currently being used to treat a variety of disorders involving immune complexes, such as polyarteritis nodosa. This procedure removes endogenous toxic components that accumulate...Full Text Available
Copper deficiency lowers brain copper and iron during development. The reduced iron content could be due to hypoferremia. Experiments were conducted to evaluate plasma iron and “ferroxidase”...Full Text Available
For supersonic plasma flow velocities, instead of the usual shelf-step profile seen for subsonic flow, an overdense bump and cavity is observed. The profile is stable for long times even for moderate power microwaves.
BackgroundHerpes simplex virus (HSV) suppressive therapy reduces genital and plasma HIV-1 RNA over periods up to three months but the longer-term effect is unknown.Full Text Available
In whole-cell recording, the conductance of the plasma membrane of protoplasts isolated from mesophyll cells of leaves of oat (Avena sativa) was greater for inward than outward current....Full Text Available
An in vitro assay for curative antibody present in plasma of mice cured of Trypanosoma musculi is described. The assay involves the addition of plasma to a sample of infected blood, followed by hourly...Full Text Available
In this paper, we report on a series of experiments designed to study the influence of plasma nitriding on the mechanical properties of austenitic stainless steel. Plasma nitriding experiments were conducted on AISI 304L steel in a temperature range of 375-475 C using pulsed-DC plasma with different N{sub 2}-H{sub 2} gas mixtures and treatment times. Firstly the formation and the microstructure of the modified layer will be highlighted followed by the results of hardness measurement, adhesion testing, wear resistance and fatigue life tests. The modified surface was analyzed directly after plasma nitriding as well as using a depth profiling method. The microhardness after plasma nitriding is increased up to 19 GPa, that is a factor of five higher compared to the untreated material (3.3 GPa). The adhesion is examined by Rockwell indentation and scratch test. No delamination of the ...
The present article studies the electret state of polymers when moving through an alternating-current corona discharge plasma and investigates means for the determination of the transition of the polymeric material from the initial state of the electret when the corona-displaying voltage is increased.
Eight of 100 normotensive children who had pyelonephritic scarring secondary to urinary infection and vesicoureteric reflux were found in an earlier study to have increased plasma renin activity (PRA)....Full Text Available
During antibiotic drug development, media are frequently spiked with either serum/plasma or protein supplements to evaluate the effect of protein binding. Usually, previously reported serum or plasma...Full Text Available
A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).
BACKGROUND AND OBJECTIVE:For treatment of benign prostatic hyperplasia (BPH), Plasma Kinetic loop Resection of the Prostate (PKRP) is an alternative to conventional monopolar...Full Text Available
Computational fluid dynamics are applied to the study of three-dimensional fluid flow in a dense medium plasma reactor (DMPR) under different operating conditions. Reaction mechanisms and rates for the removal of methyl t-butyl ether (MTBE) in a DMPR are developed from experimental data to determine the plasma volume, the rate of interphase mass transfer and the photolysis rate of MTBE via UV emission from the plasma. The simulations utilize the plasma volume determined from the kinetic data to show that the volume of fluid in contact with the plasma in the DMPR only constitutes a maximum of approximately 10% of the fluid intended to be cycled through the plasma tubules. The simulations also predict appreciable pressure gradients on the surface of the pin electrodes, resulting in a small discharge area located away from the region in which the electric field ...
Recent results of the experiments at GOL-3 facility are presented. Plasma with a density of 1014...1016 cm-3 is confined in a 12-meter-long solenoid, which comprises 55 corrugation cells with mirror ratio Bmax/B min=4.8/3.2 T. The plasma is heated up to 2...4 keV temperature by a high power relativistic electron beam (?1 MeV, ? 330 kA, ?8?s, ?120 kJ) injected through one of the ends. Mechanism of experimentally observed fast ion heating, issued of plasma stability and confinement are discussed.
Surface probe and laser-induced fluorescence measurements in ISX-B and EBT-S have made significant contributions to the understanding of plasma edge characteristics and plasma-surface interactions in these devices. Where comparison is possible, these techniques have led to results which are consistent with plasma diagnostics. Charge-exchange neutral sputtering and self-ion sputtering have been identified as the dominent heavy impurity release mechanisms in ISX-B and EBT-S, respectively.
Atmospheric pressure plasma enhanced chemical vapour deposition system is built. The electrical and optical characteristics of the APPECVD system is given. The system is used to deposit conductive polymers and nano composites onto glass and metal surfaces. The morphological, optical, chemical and electrical characteristics of deposited surfaces are investigated using SEM, AFM four probe deposition purposes. The photovoltaic applications of plasma deposited polymers and nonconsumption are compared with deposited with electrochemical methods show different results. The electrical, chemical and morphological structures of the samples will be given.
Closing and breaking of current in microsecond megaampere plasma opening switches are considered. Conductivity current scaling in the switch due to plasma acceleration by a magnetic piston is discussed and compared with experimental data. Two ways of determining the width of a current channel are taken up. This channel results from the diffusion of the magnetic field in the plane of the piston followed by the convective ejection of the field frozen in the accelerated plasma flow behind the shock wave into the bridge. Based on experimental data, a scaling law for the voltage on the switch according to the switch parameters is derived. The problem of reverse closing, which limits the efficiency of storage energy extraction into the load, is considered
Non-thermal plasma treatment is a promising technique for the destruction of volatile organic compounds in waste gas. A relatively unexplored technique is the atmospheric negative dc multi-pin-to-plate glow discharge. This paper reports experimental results of allyl alcohol degradation and ozone production in this type of plasma. A new model was developed to describe these processes quantitatively. The model contains a detailed chemical degradation scheme, and describes the physics of the plasma by assuming that the fraction of electrons that takes part in chemical reactions is an exponential function of the reduced field. The model captured the experimental kinetic data to less than 2 ppm standard deviation.
The ionization, excitation, and radiative recombination rates for highly stripped ions are cal- culated with Maxwellian and non-Maxwellian electron distribution functions of the type Cmexp(-vm/wm) (2<=m<=5) as encountered in laser-heated plasmas and certain types of turbulent plasmas. The direct-radiative-recombination rates are found to decrease by at most 30% as m is increased from 2 to 5. On the other hand, the ionization and excitation rates are found to be strongly reduced if the transition energy ? exceeds twice the local temperature kBTe. The effect of this on the distribution of energy levels and degrees of ionization in laser-produced plasmas could be important.
Measurements of the expansion rate of pure-electron plasmas have been performed on the Electron Diffusion Gauge (EDG) device at background helium gas pressures in the 5 x 10(superscript -8) Torr to 1 x 10(superscript -5) Torr range, where plasma expansion due to electron-neutral collisions dominates over plasma expansion due to trap asymmetries. It is found that the expansion rate, defined as the time rate of change of the particles' mean-square radius, scales approximately linearly with pressure and inversely as the square of the magnetic field strength in this regime, in agreement with classical predictions.
A clear and reproducible transition to a regime with an improved particle confinement is routinely observed on the CASTOR tokamak, if the biasing electrode is inserted deep enough into the plasma (r/a?0.5) and biased up to +250 V. The steepening of the radial profiles of the plasma density and potential demonstrate the formation of a transport barrier just inside the last closed flux surface. Fast relaxations of the edge plasma parameters, with a frequency of about 10 kHz, are observed when the average radial electric field within the barrier prevails values of about 20 kV/m. A detailed analysis of the spatial-temporal behaviour of these relaxations is presented.
We develop a new cavity with a mode similar to TE13 to produce microwave plasma, named APMPS II, which is able to produce a mass of air plasma with diameter of around 6 cm, equipped with about 3 kW input power under one atmosphere. The plasma seems to be homogeneous without significant filamentous discharge as observed by common camera device. We present the theory of this cavity, show the distribution of electric field of several planes inside the cavity and give some experimental results. (authors)
Properties of the multi-species electromagnetic Weibel and electrostatic two-stream instabilities are investigated for an intense ion beam propagating through background plasma. Assuming that the background plasma electrons provide complete charge and current neutralization, detailed linear stability properties are calculated within the framework of a macroscopic cold-fluid model for a wide range of system parameters.
Surface deposition probe techniques have been shown to be an effective means of determining the characteristics of the plasma edge region of magnetic confinement devices. Experimental results on ISX-B and EBT-S have led to a consistent picture of the edge plasma and the dominant impurity introduction mechanisms. This picture is supported by numerous other measurements and emphasizes the importance of concentrating several techniques on the complex problems of plasma fusion.
Complimentary spectroscopic, microscopic and electrochemical studies were performed to characterise the barrier properties as well as the interface structure of model iron substrates covered with thin plasma polymer films. Cathodic plasma polymers were deposited which show high barrier properties. The metal surface was pre-treated by a reducing or oxidising plasma. This allowed the adjustment of the oxidation state of the interface layer. The interface structure was characterised by means of X-ray photoelectron sputter profiles, infrared spectroscopy and the application of a Kelvin probe. The investigations show that the measured Voltapotential on the plasma polymer surface can be correlated with the oxidation state of the interface. Reducing plasmas lead to an almost oxide free surface. After deposition of the plasma polymer, this reduced state of the oxide is ...
Three dimensional rotatory modes of oscillations in a one-dimensional chain of rodlike charged particles or dust grains in a plasma are investigated. The dispersion characteristics of the modes are analyzed. The stability of different equilibrium orientations of the rods, phase transitions between the different equilibria, and a critical dependence on the relative strength of the confining potential are analyzed. The relations of these processes with liquid crystals, nanotubing, and plasma coating are discussed.
An intermetallic compound Sm[sub 2]Fe[sub 17]N[sub x] was synthesized by plasma nitriding of Sm[sub 2]Fe[sub 17] in a stream of N[sub 2]-H[sub 2] mixed gas. The reaction proceeded at a lower temperature (around 423 K) than that of the conventional thermal technique, but not at room temperature. This is discussed on the basis of the difference between the reaction mechanisms of plasma and thermal nitridings. (orig.)
We have investigated the effect of plasma nitriding and plasma nitrocarburizing on the microstructure and properties of electroplated chromium. Plasma nitriding and plasma nitrocarburizing are applied to 15-100 [mu]m thick electroplated hard chromium coatings to increase both the wear and the corrosion resistance. The properties of the plasma-modified hard chromium layers are characterized by measuring the wear resistance with a Taber wear tester and the corrosion resistance with a salt spray fog test. Cyclic voltammetry is performed in a standard electrochemical cell using a 0.5 M H[sub 2]SO[sub 4] solution acidified to pH 0.3. The compound layer after plasma nitriding consists of CrN and Cr[sub 2]N with a maximum hardness of about 1100 HK[sub 0.01]. After plasma nitrocarburizing, Cr[sub 3]C[sub 2] and Cr[sub 7]C[sub 3] are formed. After ...
Field reversed configuration (FRC) is a prospective high ? magnetic system for high efficiency D- 3He fusion reactor. Self-consistent FRC plasma profiles and static electric field for reactor calculations are discussed in framework of the model including flow equilibrium and collisionless transport equations. The extrapolations to reactor regimes of plasma confinement scaling laws are considered.
The qualitative technique of the analysis of the efficiency of the RF plasma production is presented in which the solution of boundary problem for Maxwell's equations is only necessary. The analysis of the character of the plasma production process with the crankshaft antenna in Uragan-2M stellarator is carried out. The discussion of the calculations results is presented.
Electromagnetic effects excited by intense relativistic electron beams in plasmas are investigated using a two-dimensional particle code. The simulations with dense beams show large magnetic fields excited by the Weibel instability as well as sizeable electromagnetic radiation over a significant range of frequencies. The possible relevance of beam plasma instabilities to the laser acceleration of particles is briefly discussed. 6 refs., 4 figs.
The fundamental ionisation process of negative surface ionisation is described and two applications are discussed. One is in the so called surface-plasma sources which enable the production of intense negative ion beams. The second application is in the passive diagnosis of the charge exchange of neutrals emitted from hydrogen plasmas.
This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) To prepare the project's final report. This report ...
A general theoretical approach for the study of the two-dimensional structure of high-n Toroidal Alfven Eigenmodes (TAE) in finite-#beta#, large aspect ratio (R_o/a much-gt 1) tokamak equilibria is presented. Here, n is the toroidal mode number, #beta# = plasma/magnetic pressure, and a(R_o) is the minor (major) radius of the torus. It is shown how the general pseudo-differential boundary value problem for the radial eigenmode structure can be systematically constructed from the local dispersion relation; which is obtained using the ballooning formalism. The TAE modes are characterized by a broad radial envelope, the width of which is independent on the mode number in the general case of monotonic equilibrium profiles. The results on the two-dimensional eigenmode structure are expected to be applicable to drift-type waves. The ballooning transform is generalized here to handle singular eigenfunctions typical of the continuous shear Alfven ...
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are collected with a ...
Non-thermal (low-temperature) physical plasma is under intensive study as an alternative approach to control superficial wound and skin infections when the effectiveness of chemical agents is weak due to natural pathogen or biofilm resistance. The purpose of this study was to test the individual susceptibility of pathogenic bacteria to non-thermal argon plasma and to measure the effectiveness of plasma treatments against bacteria in biofilms and on wound surfaces. Overall, Gram-negative bacteria were more susceptible to plasma treatment than Gram-positive bacteria. For the Gram-negative bacteria Pseudomonas aeruginosa, Burkholderia cenocepacia and Escherichia coli, there were no survivors among the initial 10(5) c.f.u. after a 5 min plasma treatment. The susceptibility of Gram-positive bacteria was species- and strain-specific. Streptococcus pyogenes was the most resistant with 17?% ...
The authors address the question of the limitations on voltage and current transfer to loads in magnetic storage systems utilizing microsecond conduction time plasma opening switches. They propose that the limitation of performance results from neutral atoms that are not entrained into the ionized material that is driven by the magnetic field of the rising generator current. Evidence in support of this proposition is gathered from experiments performed on the Ace-4 and Hawk generators. They set forth a theory to describe the effect of neutrals on the electrical performance of plasma opening switches. The neutral gas is assumed to be present in the region between the moving plasma mass and the generator, primarily in the region in which the plasma is injected initially. The essential elements of the theory are a weak photoionization source to seed the gas with a low concentration of electrons, and joule ...
To clarify the mechanism of plasma nitriding, the authors examined the optical microstructure, the hardness, the precipitation, and the concentration of dissolved nitrogen in Fe-18Cr-9Ni nitrided using plasma in the range of 723-823 K. Compared with ammonia-gas nitriding, the features of plasma nitriding are the formation of small chromium-nitride precipitates (CrN), the absence of an externally nitrided layer, the high concentration of dissolved nitrogen, and the high hardness (HV = 1,200). The diffusion coefficient of nitrogen in the present alloy was determined using the growth rate of the internally nitrided layer, based on calculations used in internal oxidation. Plasma- and gas-nitriding were also compared with respect to the growth rate of the nitrided layer.
Plasma nitriding was applied to improve the surface performance of titanium bipolar plate. XRD and SEM results showed a titanium nitride layer was formed after nitridation. In comparison with pure titanium, the interfacial contact resistance of plasma nitrided titanium was reduced to some extent by the nitridation treatment. However, high corrosion current was observed under electrochemical tests in 0.5 M H{sub 2}SO{sub 4} + 5 ppm HF. Both the electrical conductivity and corrosion resistance of the surface of plasma nitriding titanium did not reach the level of graphite. Some more improvements are expected in the plasma nitriding process or another surface modification on pure titanium. (author)
The physics of density limit phenomena in toroidal helical plasmas based on an analytic point model of toroidal plasmas is discussed. The combined mechanism of the transport and radiation loss of energy is analyzed, and the achievable density is derived. A scaling law of the density limit is discussed. The dependence of the critical density on the heating power, magnetic field, plasma size and safety factor in the case of L-mode energy confinement is explained. The dynamic evolution of the plasma energy and radiation loss is discussed. Assuming a simple model of density evolution, of a sudden loss of density if the temperature becomes lower than critical value, then a limit cycle oscillation is shown to occur. A condition that divides the limit cycle oscillation and the complete radiation collapse is discussed. This model seems to explain the density limit oscillation that has been observed on the W7-AS ...
Interest in the tribological properties of plasma nitriding has increased substantially over the past years because plasma nitriding provides a high nitride depth and improved hard facing. The present study examines the tribological properties of AISI H11 plasma nitrided, hot-worked steel. Different nitriding temperatures and durations were considered. Characterization of the composite structures was investigated with wear tests, x-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), and microhardness tests. The depth profile of the nitrided zone was measured using the nuclear reaction analysis (NRA) technique. Plasma nitriding affected the microhardness, wear properties, and morphology considerably. Increase in process temperature increased the nitride zone depth.
We report on the formation of current blocking regions by O2 plasma treatment to reduce current crowding at the active region above the p-type electrodes of GaN-based vertical light emitting diodes (LEDs). The forward voltage and reverse current (at -5 V) of the plasma-treated LEDs slightly increase with increasing aging time. The output power (at 350 mA) of the plasma-treated LEDs is enhanced by 26% as compared to that of reference LEDs and is comparable to that of LEDs with SiO2 current blocking layers. It is shown that the output power (at 700 mA) of the plasma-treated LEDs is degraded by less than 2% of the initial value after 500 h.
In this work AISI 1045 steel were duplex treated via plasma nitriding of chromized layer. Samples were pack chromized by using a powder mixture consisting of ferrochromium, ammonium chloride and alumina at 1273K for 5h. The samples were then plasma-nitrided for 5h at 803K and 823K, in a gas mixture of 75%N2+25%H2. The treated specimens were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) analysis and Vickers micro-hardness test. The thickness of chromized layer before nitriding was about 8mm and it was increased after plasma nitriding. According to XRD analysis, the chromized layer was composed of chromium and iron carbides. Plasma nitriding of chromized layer resulted in the formation of chromium and iron nitrides and carbides. The hardness of the duplex layer...
We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)
Plasma Technologies in Institute of Plasma Physics of the NSC KIPT are recently developed in the following directions. Material surfaces modification under their irradiation with pulsed plasma streams of different working gases. Besides traditional analysis of improvements of tribological characteristics and structural-phase changes of the modified layers recently we started investigations of material corrosions characteristic improvement under influence of pulsed plasma on the material surfaces. As to the surface coatings in arc discharges of Bulat type devices, new trends are related with multi-layers coatings, using Ti-AI-N coatings in cutting tools, using high frequency discharges or combined HF- and arc discharges for increasing the nomenclature of goods to be coated. Development of ozonators is respectively new area for IPP NSC KIPT. On the base of barrier high-frequency discharge there were ...
Plastic composites have become a large class of construction material for exterior applications. One of the main disadvantages of wood plastic composites resides in the weak adhesion between the polar and hydrophilic surface of wood and the non-polar and hydrophobic polyolefin matrix, hindering the dispersion of the flour in the polymer matrix. To improve interfacial compatibility wood flour can be pretreated with environmentally friendly methods such as cold-atmospheric pressure plasma. The objective of this work is therefore to evaluate the potential of plasma polymerization of acetylene on wood flour to improve the compatibility with polyolefins. This presentation will describe the reactor design used to modify wood flour using acetylene plasma polymerization. The optimum conditions for plasma polymerization on wood particles will also be presented. Finally preliminary results on the wood flour ...
Hydrogen (H) plasma treatment, oxygen (O) plasma treatment and water (H_2O)-vapor heat treatment for polycrystalline-silicon (poly-Si) thin-film transistors (TFTs) have been analyzed by separately extracting trap density at a front silicon-oxide interface (D_F) and trap density at a back interface (D_B). It is found that the H plasma treatment is apt to generate D_F and D_B. The O plasma treatment reduces D_F, while the H_2O-vapor heat treatment reduces both D_F and D_B. Improvement of transistor characteristics of poly-Si TFTs depends on understanding these results.
It has been previously stated that the minimum physiological recommendations for the indispensable amino acids in health adults, as proposed by FAO/WHO/UNU in 1985, are far too low, except for the methionine. An amino acid stable isotopic kinetic study was conducted to seek further experimental support to this hypothesis. Twenty healthy young men received an l-amino acid based diet, supplying 140 mg N.kg"-"1.d"-"1, patterned on egg protein for 1 week, then for 3 weeks either i) a pattern based on current international recommendations (FAO diet, n=7), ii) a the tentative Laboratory of Human Nutrition of the Massachusetts Institute of Technology, new amino acid recommendation pattern (MIT diet, n=7) or iii) again the egg hen pattern (EGG diet, n=6). All subjects were again studied for one final, consecutive week of the egg diet. At the end of the initial week, at the first and third week with the three experimental diets,and after three days following the return of the egg diet, an 8 h ...
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...
We use a massively parallel 3D hybrid particle code, dHybrid, to simulate the deflection of plasma beams by a dipole like magnetic field in a laboratory environment. Dipole magnetic fields, along with a plasma injection source to inflate the magnetic field, are now being studied as means of deflecting solar wind and Energetic Particles away from spacecrafts [1,2,3]. We have considered three setups, consistent with the experiments, with a plasma beam fired at i) a dipole field with no plasma injection, ii) a plasma injection source with no dipole field and iii) a dipole field with a plasma injection source. The hybrid simulations help understand the relevant physical phenomena, and enable extrapolation to space plasma scenarios, where setups are similar but plasma parameters differ significantly. The simulation results ...
A theoretical model is presented to describe the electromagnetic, heat transfer and fluid flow phenomena within a magnetron plasma torch and in the resultant plume, by using a commercial computational fluid dynamics (CFD) code FLUENT. Specific calculations are presented for a pure argon system (i.e., an argon plasma discharging into an argon environment), operated in a turbulent mode. An important finding of this work is that the external axial magnetic field (AMF) may have a significant effect on the behavior of arc plasma and thus affects the resulting plume. The AMF impels the plasma to retract axially and expand radially. As a result, the plasma intensity distribution on the cross section of torch seems to be more uniform. Numerical results also show that with AMF, the highest plasma temperature decreases and the anode arc root moves upstream significantly, ...
Surface compositional changes in GaAs due to RF plasmas of different gases have been investigated by XPS and etch rates were measured using AFM. Angular Resolved XPS (ARXPS) was also employed for depth analysis of the composition of the surface layers. An important role in this study was determination of oxide thickness using XPS data. The study of surface - plasma interaction was undertaken by correlating results of surface analysis with plasma diagnosis. Different experiments were designed to accurately measure the BEs associated with the Ga 3d, Ga 2p sub 3 sub / sub 2 and LMM peaks using XPS analysis and propose identification in terms of the oxides of GaAs. Along with GaAs wafers, some reference compounds such as metallic Ga and Ga sub 2 O sub 3 powder were used. A separate study aiming the identification of the GaAs surface oxides formed on the GaAs surface during and after plasma processing was ...
By using a plasma nitriding procedure at the PUPR Mirror Cusp Plasma machine, surface hardness is increased in 302/304-type stainless steel samples by exposing them to high-ion-density plasma at high vacuum. This method successfully dopes the surface of the material with strengthening nitrogen ions, without the use of chemical procedures that sacrifice the resistance to corrosion of the given material. A 500 V negative bias is placed on the sample exposed to the nitrogen plasma, where high-energy ions are therefore attracted and immersed into the metallic matrix microns into the surface of the stainless steel. This potential maintains a constant surface temperature at approximately 800 deg. C. The plasma parameters including ion density and plasma temperature were diagnosed using single Langmuir probes. The stainless steel samples were then tested using scanning ...
By using a plasma nitriding procedure at the PUPR Mirror Cusp Plasma machine, surface hardness is increased in 302/304-type stainless steel samples by exposing them to high-ion-density plasma at high vacuum. This method successfully dopes the surface of the material with strengthening nitrogen ions, without the use of chemical procedures that sacrifice the resistance to corrosion of the given material. A 500 V negative bias is placed on the sample exposed to the nitrogen plasma, where high-energy ions are therefore attracted and immersed into the metallic matrix microns into the surface of the stainless steel. This potential maintains a constant surface temperature at approximately 800 deg. C. The plasma parameters including ion density and plasma temperature were diagnosed using single Langmuir probes. The stainless steel samples were then tested using scanning ...
Simultaneous nitriding and ageing heat treatments of precipitation hardenable tool steel was carried out inside a DC-pulsed plasma nitriding reactor. A single heat treatment cycle was done, as the plasma nitriding and age hardening processes occur approximately at the same ranges of temperatures and times. Specimens of Cr-Ni-Mo-Al age hardenable steel, in the solubilized and solubilized and aged conditions, were tested. Plasma nitriding and ageing, carried out at 500 deg. C for times ranging between 2 and 8 h, increased the surface hardness up to 1000 HV, producing case depths between 100 and 200 {mu}m. The core hardness of solubilized samples increased from 30 to 39 Rockwell C after the plasma nitriding treatment proving the possibility of nitriding and ageing at the same treatment cycle. The pre-aged samples did not show any overageing after the simultaneous plasma nitriding and ...
Simultaneous nitriding and ageing heat treatments of precipitation hardenable tool steel was carried out inside a DC-pulsed plasma nitriding reactor. A single heat treatment cycle was done, as the plasma nitriding and age hardening processes occur approximately at the same ranges of temperatures and times. Specimens of Cr-Ni-Mo-Al age hardenable steel, in the solubilized and solubilized and aged conditions, were tested. Plasma nitriding and ageing, carried out at 500 deg. C for times ranging between 2 and 8 h, increased the surface hardness up to 1000 HV, producing case depths between 100 and 200 #mu#m. The core hardness of solubilized samples increased from 30 to 39 Rockwell C after the plasma nitriding treatment proving the possibility of nitriding and ageing at the same treatment cycle. The pre-aged samples did not show any overageing after the simultaneous plasma nitriding and ...
Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The ...
Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The ...
Here we describe the use of low energy plasma immersion with active screen as a convenient approach for polypropylene (PP) surface modification. Employing a stainless steel cathodic cage coated with carbon in order to prevent the sputtering of iron from the grid and its deposition onto the polymer sample, the physical chemical properties of PP surface could be effectively modified through the plasma-induced incorporation/formation of nitrogen- and oxygen-containing species. The areal densities of these elements depended on the plasma excitation source, as determined by Rutherford backscattering spectrometry (RBS). Newly formed C-O, C-N, and C=O/O=C-O/N-C=O bonds along with C-C linkages from the PP backbone were identified at the near surface region of the specimens by X-ray photoelectron spectroscopy (XPS). The insertion of such polar reactive functionalities was further confirmed by a substantial decrease in the water ...
The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested ...
Using the ammonia (NH3) plasma generated by a helical antenna surrounded by two magnetic coils, the transition of the discharge mode from low-density plasma to high-density one was observed. At the transition, the emission intensities from the H atoms and NH radicals especially increased in the optical emission spectroscopy, while the intensities of the other emission lines also increased abruptly. The nitridation of gallium arsenide (GaAs) surface was performed using the high-density NH3 plasma, and the properties of the nitrided surface layer were compared with those nitrided by high-density N2 plasma using the same apparatus. From the spectroscopic ellipsometry measurements, the thickness of the nitrided layer was estimated to be 16-18 nm, while that by N2 was 3-4 nm. From the Ga 3d spectra, the contamination with oxygen in the nitridation layer by NH3 plasma was less than that ...
The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load ...
The subfornical organ is a major receptor area for one of the principal stimuli of thirst, the octapeptide, angiotensin II. In conscious water-sated rats, the authors examined the effects of intravenous infusion of angiotensin II on the rate of glucose utilization in the subfornical organ and in structures anatomically and functionally connected with it. Angiotensin II produced pressor and drinking responses and increased glucose utilization selectively in the subfornical organ and pituitary neural lobe and in no other brain structure. Treatment with the angiotensin II antagonist, sar1-leu8-angiotensin II, before intravenous administration of angiotensin II prevented metabolic stimulation of the subfornical organ and neural lobe. Captopril, an inhibitor of angiotensin-converting enzyme, reduced subfornical organ glucose metabolism to a level similar to that found in control animals. These results demonstrate that peripheral angiotensin II stimulates glucose ...
The gammaretrovirus, xenotropic murine leukemia virus-related virus (XMRV), replicates to high titers in some human cell lines and is able to infect non-human primates. To determine whether APOBEC3 (A3) proteins restrict XMRV infections in a non-human primate model, we sequenced proviral DNA from peripheral blood mononuclear cells of XMRV-infected rhesus macaques. Hypermutation characteristic of A3DE, A3F and A3G activities was observed in the XMRV proviral sequences in vivo. Furthermore, expression of rhesus A3DE, A3F, or A3G in human cells inhibited XMRV infection and caused hypermutation of XMRV DNA. These studies show that some rhesus A3 isoforms are highly effective against XMRV in the blood of a non-human primate model of infection and in cultured human cells. PMID:21982221
Biomonitoring of human populations for exposure to genotoxic/clastogenic agents in the environment or the workplace must depend upon statistical tests for elevations in the frequencies of the biological endpoints being monitored, usually chromosomal aberrations (CA), micronuclei (MN), or sister chromatid exchanges (SCE) in peripheral blood lymphocytes. Statistical tests are based, in turn, upon certain assumptions regarding the distribution of the test statistic. When they are often not recognized as such, tests of significance can be in error, and any conclusion drawn that there is or is not a statistically significant difference between one population sample and another maybe erroneous. In population monitoring this means either false negatives or false positives can result and it is hard to know which is worse. Furthermore, even the intelligent design of studies whose object is to test for an elevated level in an exposed population must depend upon prior ...
We report measurements for coherent rho^0 production, AuAu->AuAu rho^0, and coherent rho^0 and e^+e^- pair production accompanied by mutual nuclear Coulomb excitation, AuAu->Au*Au* rho^0 and AuAuee, in ultra-peripheral relativistic gold-gold collisions (UPC). We discuss transverse momentum, mass, and rapidity distributions. The two photon-process of e^+e^- pair production is an important probe of strong field QED because of the large coupling Z*alpha=0.6. At sqrt{s}=200GeV, the e^+e^- production cross section agrees with lowest order QED calculations. The cross sections for coherent rho^0 production at sqrt{s}=130 and 200GeV are in agreement with theoretical predictions. The calculations for both, coherent e^+e^- and rho^0 production treat nuclear excitation as independent process.
Plasma neutralization of an intense ion pulse is of interest for many applications, including plasma lenses, heavy ion fusion, cosmic ray propagation, etc. An analytical electron fluid model has been developed based on the assumption of long charge bunches (l{sub b} >> r{sub b}). Theoretical predictions are compared with the results of calculations utilizing a particle-in-cell (PIC) code. The cold electron fluid results agree well with the PIC simulations for ion beam propagation through a background plasma. The analytical predictions for the degree of ion beam charge and current neutralization also agree well with the results of the numerical simulations. The model predicts very good charge neutralization (>99%) during quasi-steady-state propagation, provided the beam pulse duration {tau}{sub b} is much longer than the electron plasma period 2{pi}/{omega}{sub p}, where {omega}{sub ...
Gyrokinetic particle simulation of edge pedestal formation and plasma rotation dynamics will be presented, and compared with experimental observations. Realistic tokamak edge geometry is used which include separatrix/X-point and material wall from EFIT g-eqdsk data. In order to handle adequately the spatially inhomogeneous electric potential in the scrape-off region, the full-f electron technique is used, in addition to the full-f ions. Monte Carlo neutral particles with wall recycling coefficient will be included self-consistently with the plasma kinetics. Ion-ion Coulomb collisions will be particle, momentum and energy conserving. Energy source for the pedestal and scrape-off plasmas is the heat flow from the core plasma, and the particle source is the ionization of the neutral atoms which are either wall recycled and/or gas puffed. The simulation will be self-consistent with the first principles ...
A study on oxygen-plasma treatment of ink-jet paper is presented. Paper was exposed to a weakly ionized, highly dissociated oxygen plasma with an electron temperature of 5 eV, a positive-ion density of 8 x 1015 m-3 and a density of neutral oxygen atoms of 5 x 1021 m-3. Optical emission spectroscopy (OES) was applied as a method for detection of the reaction products during the plasma treatment of the paper. OES spectra between 250 and 1000 nm were measured continuously during the plasma treatment. The wettability of the samples before and after the plasma treatment was determined by measuring the contact angle of a water drop. The appearance of the surface-functional groups was determined by using high-resolution x-ray photoelectron spectroscopy (XPS), while changes in the surface morphology were monitored with scanning electron microscopy (SEM). Already after 1 s of the ...
The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gas discharges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise measurement of the radial electric field. The ...
An original dc double anode plasma torch which provides a long-time and highly stable atmospheric plasma jet has been devised for the purpose of hazardous waste treatment. The arc fluctuations and dynamic behaviour of the argon and argon-nitrogen plasma jets under different operating conditions have been investigated by means of classical tools, such as the statistic method, fast Fourier transform (FFT) and correlation analysis. In our experiments, the takeover mode is identified as the fluctuation characteristic of the argon plasma jet while the restrike mode is typical in the argon-nitrogen plasma dynamic behaviour. In the case of pure argon, the FFT and correlation calculation results of electrical signals exhibit the only characteristic frequency of 150 Hz, which originates from the torch power and is independent of any change in the operating conditions. It indicates that the ...
Various kinds of decontaminations are carried out in atomic power plant. Here current decontamination technologies such as chemical decontamination with chemical solution or blast decontamination have a problem of reduction of secondary radioactive waste generated in the decontamination process. On the other hand, a low pressure arc plasma can remove metal oxide film on the metal substrate without heavy damage on the metal substrate when the object to be treated was set as a cathode. Dry surface decontamination technology with using low-pressure arc plasma can decrease secondary radioactive waste because low-pressure arc plasma does not need any chemical solution. In addition, the time required for treatment can be shorter, so it is possible for the low-pressure arc plasma decontamination technology to interpolate the current decontamination technologies such as spot decontamination technology etc. ...
In a treatment system of radioactive waste solution including sodium sulfate generated from a boiling water type nuclear reactor, waste solution is fed into a thin film evaporator where the waste solution is evaporated and made into powder while precipitating in a peripheral surface of the evaporator vessel. The surface of the precipitated solid is wiped by rotating wiper blades and removed off as radioactive solid powder. The rotational speed of a rotor to which the wiper blades are secured is controlled at a minimum and necessary rotational speed which contributes to make the waste solution into the powder so that the rate of worn out of the wiper blade is decreased.
The authors describe the production of two mouse hybridomas secreting monoclonal antibodies to antigenic determinants of the surface membranes of human neutrophils, activated T lymphocytes, and acute leukemic blast cells. The degree of lymphocyte stimulation was estimated from incorporation of /sup 3/H-thymidine with parallel microculture. Monoclonal antibodies of supernatants of hybridoma cultures shown here reacted in both immunofluorescence test and cytotoxicity test with surface membrane antigens on the majority of neutrophils and PHA-activated peripheral blood lymphocytes from healthy subjects, but did not give positive reactions with unactivated lymphocytes, adherent monocytes, erythrocytes, and alloantigen-stimulated lymphocytes.
Visceral hypersensitivity is currently considered a key pathophysiological mechanism involved in pain perception in large subgroups of patients with functional gastrointestinal disorders, including irritable bowel syndrome (IBS). In IBS, visceral hypersensitivity has been described in 20%?90% of patients. The contribution of the central nervous system and psychological factors to visceral hypersensitivity in patients with IBS may be significant, although still debated. Peripheral factors have gained increasing attention following the recognition that infectious enteritis may trigger the development of persistent IBS symptoms, and the identification of mucosal immune, neural, endocrine, microbiological, and intestinal permeability abnormalities. Growing evidence suggests that these factors ...
We report the case of a 22-year-old man with Ewing's sarcoma who attained a complete remission (CR) after combination radiotherapy and chemotherapy. Secondary acute lymphoblastic leukemia with multiple cytogenetic abnormalities involving chromosome 5 and 7 developed 16 years later. The patient underwent induction chemotherapy and entered a CR. Peripheral blood stem cell transplantation from a matched sibling was performed successfully and he is in complete remission of both ALL and Ewing's sarcoma. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
A sifter is proposed, which includes a frame, a sifting surface in the form of transverse grates, positioned on a hinge and lever mechanism, one of the axis of the hinges of which is connected with the frame and the other, with a movable frame, which is adjoined with the drive pushrod for changing the width of the slots between the grates. To increase the effectiveness of initial classification through periodic cleaning of the sifting surface, the hinge and lever mechanism is made in the form of a multiple parallelogram, while the grates are formed by one of the peripheral axes of the hinges of the parallelogram. The movable frame is installed with the capability of attachment to different axes of the parallelogram hinges. The frame is U shaped.
Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood samples were prepared and exposed to challenge dose of 0 and 2 Gy. Lymphocytes were scored using analysis of metaphase, for the ...
The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy ...
The wear behaviour of 722M24 (En40B) steel plasma nitrided at high temperatures for long durations was investigated. Under dry sliding and abrasive-containing lubricated conditions, the wear characteristics of the steel were studied as a function of load, time and white layer thickness. The white layer and the wear debris were characterized by X-ray diffraction. The topography of the wear surface was examined in a scanning electron microscope. The plasma nitriding process was carried out using a 20 kW plasma processing unit in cracked ammonia atmosphere. Treatment times of up to 100 h were employed with temperatures of 550, 570 and 590 C. Wear tests were performed with plasma nitrided AMS 6472 as the counterface material. The tests under abrasive-containing lubricated conditions were carried out with 10% carborundum powder 10 [mu]m in size in SAE-30 machine oil. The wear resistance of the steel was ...
The basic idea is to implement Thomson scattering with free electron laser (FEL) radiation at near-solid density plasmas as a diagnostic method which allows the determination of plasma temperatures and densities in the warm dense matter (WDM) regime (free electron density of n{sub e} = 10{sup 21}-10{sup 26} cm{sup -3} with temperatures of several eV). The WDM regime [1] at near-solid density (n{sub e} = 10{sup 21}-10{sup 22} cm{sup -3}) is of special interest because, it is where the transition from an ideal plasma to a degenerate, strongly coupled plasma occurs. A systematic understanding of this largely unknown WDM domain is crucial for the modeling and understanding of contemporary plasma experiments, like laser shock-wave or Z-pinch experiments as well as for inertial confinement fusion (ICF) experiments as the plasma evolution follows its path through this ...
The present work describes the surface improvement and biocompatibility of TiAl{sub 24}Nb{sub 10} intermetallic alloy using rf plasma nitriding. The nitriding process was carried out at different plasma power from 400 W to 650 W where the other plasma conditions were fixed. Grazing incidence X-ray diffractometry (GIXRD), Auger electron spectroscopy (AES), tribometer and a nanohardness tester were employed to characterize the nitrided layer. Further potentiodynamic polarization method was used to describe the corrosion behavior of the un-nitrided and nitrided alloy. It has been found that the Vickers hardness (HV) and corrosion resistance values of the nitrided layers increase with increasing plasma power while the wear rates of the nitrided layers reduce by two orders of magnitude as compared to those of the un-nitrided layer. This improvement in surface properties of the intermetallic alloy is due to ...
The present work describes the surface improvement and biocompatibility of TiAl_2_4Nb_1_0 intermetallic alloy using rf plasma nitriding. The nitriding process was carried out at different plasma power from 400 W to 650 W where the other plasma conditions were fixed. Grazing incidence X-ray diffractometry (GIXRD), Auger electron spectroscopy (AES), tribometer and a nanohardness tester were employed to characterize the nitrided layer. Further potentiodynamic polarization method was used to describe the corrosion behavior of the un-nitrided and nitrided alloy. It has been found that the Vickers hardness (HV) and corrosion resistance values of the nitrided layers increase with increasing plasma power while the wear rates of the nitrided layers reduce by two orders of magnitude as compared to those of the un-nitrided layer. This improvement in surface properties of the intermetallic alloy is due to formation ...
Using standard brass alloy samples, an approach to reduce the laser-induced breakdown spectroscopy measurement uncertainty was tested and proved. Two important parameters for plasma characterization, the plasma temperature and the electron density, were applied to minimize the signal uncertainties due to uncontrollable experimental parameter variations. Results show that for the pulse-to-pulse analysis, the signal fluctuations can be significantly reduced by utilizing the plasma characteristic information. The major source for the single pulse fluctuations is the redistribution of the characteristic line at different temperatures according to the Boltzmann distribution under LTE. The change of the degree of ionization also contributes to the signal fluctuations. For the multi-pulse analysis, due to the nonlinear relationship between the plasma temperature and the line intensity, it is not applicable to ...
In a prior study, we demonstrated that certain disposable coils are contaminated with zinc and release substantial quantities of Zn during hemodialysis, producing high post-dialysis plasma Zn concentrations. The present investigation was designed to monitor plasma and dialysis fluid Zn and copper throughout dialysis and to estimate patient Zn and Cu uptake. Venous plasma, arterial plasma and coil chamber fluid were sampled periodically throughout dialysis; trace metal concentrations were determined by flame atomic absorption spectrophotometry. Release of considerable quantities of Zn from the coils into the dialysis fluid, with uptake into the patient's plasma, was found. Approximately one-half of the plasma Zn uptake occurred in the first 45 minutes. Coils from different lots released significantly different quantities of Zn. Patient uptake of Zn ...
The Versatile Toroidal Facility (VTF) is a large laboratory plasma machine of 1 meter major radius used to carry out investigations of ionospheric plasma turbulence. Spectral analysis has been performed on plasmas produced by the electron emitters. Interest has focused on the low frequencies below the lower hybrid resonance where ion acoustic and current-convective modes have been observed. Microwaves injected from a 3,000 watt magnetron produce dramatic changes to the low frequency spectrum. First, the parametric decay instability intensifies the ion acoustic modes in the region of plasma heated by the microwaves. Second, the normally dominant current-convective modes are greatly suppressed in the heated region due to the oscillating electric field of the pump wave. When the authors probe beyond the heated region, these two pump wave effects are no longer observed, presumably because the microwaves are ...
An ignition device of the plasma jet type is disclosed. The device has a cylindrical cavity formed in insulating material with an electrode at one end. The other end of the cylindrical cavity is closed by a metal plate with a small orifice in the center which plate serves as a second electrode. An arc jumping between the first electrode and the orifice plate causes the formation of a highly-ionized plasma in the cavity which is ejected through the orifice into the engine cylinder area to ignite the main fuel mixture. Two improvements are disclosed to enhance the operation of the device and the length of the plasma plume. One improvement is a metal hydride ring which is inserted in the cavity next to the first electrode. During operation, the high temperature in the cavity and the highly excited nature of the plasma breaks down the metal hydride, liberating hydrogen which acts as an additional fuel to ...
Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and ...
Although it has been established that lead is transferred in milk from mother to suckling offspring, the physiological processes and parameters involved are not well understood. Single i.v. doses (0.2 mg/kg) or p.o. doses (2 mg/kg) of radiolabeled lead were administered to lactating and nonlactating female mice, and lead concentrations in blood, plasma, and milk were determined during a 21-day period. Large differences in lead elimination were observed between lactating and nonlactation mice. A significant fraction (25%) of the initial maternal dose (absorbed dose) was transferred to the suckling pups. The ratio of lead concentration in milk to lead concentration in plasma was found to be nearly constant over time. However, the milk-to-blood concentration ratios decreased during the same period. Furthermore, the concentration of lead in milk exceeded the plasma concentration by a factor of approximately 25, indicating that ...
Inductively coupled fluorocarbon (CF4/Ar and C4F8/Ar) plasmas were used to etch HfO2, which is a promising high-dielectric-constant material for the gate of complementary metal-oxide-semiconductor devices. The etch rates of HfO2 in CF4/Ar plasmas exceeded those in C4F8/Ar plasmas. The tendency for etch rates to become higher in fluorine-rich (high F/C ratio) conditions indicates that HfO2 can be chemically etched by fluorine-containing species. In C4F8/Ar plasmas with a high Ar dilution ratio, the etch rate of HfO2 increased with increasing bias power. The etch rate of Si, however, decreasd with bias power, suggesting that the deposition of carbon-containing species increased with increasing the power and inhibited the etching of Si. The HfO2/Si selectivity monotonically increased with increasing power, then became more than 5 at the highest tested bias power. The carbon-containing species to inhibit ...
The sequence of nitride formation during the early stages of plasma nitriding of pure iron was studied by optical microscopy, SEM, TEM and x-ray diffraction. Plasma nitriding at {approximately}490 C in a 25 vol.%H{sub 2} + 75 vol.%N{sub 2} mixture starts with the formation of {gamma}{prime}-Fe{sub 4}N after 40s. Once {gamma}{prime} nucleates, it mainly spreads laterally due to diffusion shortcuts in the discontinuous surface nitride layer. Before {gamma}{prime} is continuous on the surface, {epsilon} nucleates on top of it shortly after 40S. Epsilon is then observed to grow, both inwardly and laterally along with {gamma}{prime}. A compact {gamma}{prime}/{epsilon} bilayer forms on the surface at around 100s. The kinetics of nucleation, growth and compactation of the nitrides observed in the present work was significantly more rapid than in any of the nitriding process reported in the literature, including plasma nitriding. ...
The plasma plume generated by a new type of high energy Janitor known as the railplug, is examined. The railplug is a miniaturized railgun that has the potential for improving ignition characteristics of combustible mixtures in engines. The objective of the study is to gain an uderstanding of the characteristics of the plasma created by a transparent railplug, and to validate a multidimensional computer simulation of the plasma and shock fronts. The nature of the plume emitted by the railplug was examined for three levels of electrical energy while firing into air at a pressure of 1 atm. The computer model is to be used to predict trends in railplug performance for various railplug designs, energies, and ambient conditions. The velocity of the plasma movement inside a transparent railplug was measured, as well as the velocity of the plume ejected from the cavity. A shock is produced at the initiation ...
The effect of the nitrogen uptake in {alpha}-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic {alpha}-Fe phase (50%). The 20% of specimen volume form {alpha}'-Fe and {alpha}''-Fe{sub 16}N{sub 2} phases. The last 30% occupy the {gamma}'-Fe{sub 4}N, ferro- and paramagnetic {epsilon} phases, and {gamma}-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into {alpha}-iron particles which results in the formation of paramagnetic {epsilon}({zeta})-Fe{sub 2}N phase. This phase also dominates the ...
The effect of the nitrogen uptake in #alpha#-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic #alpha#-Fe phase (50%). The 20% of specimen volume form #alpha#'-Fe and #alpha#''-Fe_1_6N_2 phases. The last 30% occupy the #gamma#'-Fe_4N, ferro- and paramagnetic #epsilon# phases, and #gamma#-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into #alpha#-iron particles which results in the formation of paramagnetic #epsilon#(#zeta#)-Fe_2N phase. This phase also dominates the surface of #alpha#-iron specimen implanted by nitrogen using ...
The effect of a carbohydrate, a 20% protein, or a carbohydrate +0.3% tryptophan TRP breakfast on plasma large neutral amino acid ratio was studied in 6 healthy men. The carbohydrate-rich meal produced shifts in plasma amino acid concentrations such that plasma TRP/LNAA ratios increased from 0.13 to 0.15 (p<0.04) and the protein meal decreased the ratio from 0.14 to 0.11 (p<0.04) after 1 hour. Addition of 0.3% TRP to the carbohydrate-rich meal increased plasma TRP/LNAA ratios more than 2-fold. The TRP containing meal was thus the only one likely to influence brain 5-HT synthesis, although the difference between the plasma TRP/LNAA ratios after carbohydrate and protein breakfasts suggests that the brain may distinguish, by synthesizing more or less 5-HT, the composition of breakfast meals. (Author).
The thermonuclear reactivity of deuterium(D) - tritium(T) fusion plasma with spin-polarized fuel has been studied. Two mechanisms of depolarization, collisions and waves, in the high temperature fusion plasma have been considered. The binary collisions have been found not to change the nuclear spin states. The waves with a frequency of a few GHz, however, changes the spin states appreciably, when {delta}B/B{sub 0} (the ratio of the amplitude of the fluctuating magnetic field to the external field) becomes larger than 10{sup -5}. (author)
Reflection coefficients of electromagnetic waves in a nonuniform plasma layer with electrons, positive ions and negative ions, covering a metal surface are investigated by using the finite-difference-time-domain method. It is shown that the reflection coefficients are influenced greatly by the density gradient on the layer edge, layer thickness and electron proportion, i.e., the effect of the negative ions. It is also found that low reflection or high attenuation can be reached by properly choosing high electron proportion, thick plasma layer, and smooth density gradient in the low frequency regime, but sharp density gradient in the high frequency regime. (authors)
Plasma generated in low-density vapor by a negative ion beam has been studied experimentally and computationally. We show that space charge neutralization of the beam occurs at very low vapor density, and that correspondingly the electron density may be much less than the beam and plasma ion densities. When there is a large local gas density, as in a charge changing cell, the resulting high electron density is also localized to the same region. Therefore, very few electrons will reach a negative ion accelerator even if it is placed one or two beam diameters from such a cell.
With the aim of optimizing the nitriding process parameters (temperature and gas mixture ) experimental studies of the plasma nitriding of Ck 15 steel were carried out, using a D. C. glow discharge. Nitriding treatments were performed at 450, 500 and 550 and N_2/H_2 volume ratio of 3/1, 1/1 and 1/3 for 5 hours. Nitriding treatment produces modified surface layer consisting of an outer compound layer and an inner diffusion layer.The plasma nitriding of Ck 15 produce single white layer consisting of #gamma#-(Fe_4N).
We show that the eigenvalue equations describing a cylindrical ideal magnetophydrodynamicsw (MHD) plasma interacting with a thin resistive wall can be put into the standard mathematical form: ??? = ??? ?. This is accomplished by using a finite element basis for the plasma, and by adding an extra degree of freedom corresponding to the electrical current in the thin wall. The standard form allows the use of linear eigenvalue solvers, without additional interations, to compute the complete spectrum of plasma modes in the presence of a surrounding restrictive wall at arbitrary separation. We show that our method recovers standard results in the limits of (1) an infinitely resistive wall (no wall), and (2) a zero resistance wall (ideal wall).
Experiments are described on a plasma cathode with biased grids to prevent entry of ions into the electron extraction gap. The cathode has potential applications to the generation of high-current pulsed electron beams. Operation at 20 A/cm"2 is theoretically possible. The source combines the low average power consumption of a plasma cathode with many of the attractive features of thermionic cathodes, such as space-charge-limited extractor gap electron flow, fast turn-on, and no diode closure. Initial experiments are reported at the 2 A/cm"2 level for pulse lengths to 160 #mu#s.
Dimethyl methylphosphonate (DMMP), a chemical simulant of the nerve gas GB, was decontaminated with a nonthermal atmospheric pressure plasma. The decontamination efficiency was measured qualitatively by means of Fourier transform spectroscopy and quantitatively by means of gas chromatography. With helium gas only, 10g/m2 of DMMP on an aluminum surface was 99.9% decontaminated in 2min, furthermore, with the addition of 5% of oxygen gas, it was 99.99% decontaminated in 10min. Given the low input power (<100W) and temperature (<75degreeC), this plasma is eligible for nondestructive decontamination of almost all material surfaces.
The validity is given to the newly proposed two {delta}f method for neoclassical transport calculation, which can be solve the drift kinetic equation considering effects of steep plasma gradients, large radial electric field, finite banana width, and an orbit topology near the axis. The new method is applied to the study of ion transport with steep plasma gradients. It is found that the ion thermal diffusivity decreases as the scale length of density gradient decreases, while the ion particle flux due to ion-ion self collisions increases with increasing gradient. (author)
A brief review is presented of transport in the boundary region of magnetized plasmas by blob-like filaments. Such structures have enhanced levels of particles and heat, are elongated along the magnetic field lines and are localized in the drift plane across the field. The motion of an isolated blob structure is described in some detail and the contribution of such filaments to turbulence-driven transport are discussed. Results are presented from numerical simulations and probe measurements in tokamak plasmas. An interpretation is given of the measured dependence of particle density and transport on experimental control parameters in the scrape-off layer. (author)