Energy Technology Data Exchange (ETDEWEB)
To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT ...
2001-08-01
Utility of CT in the diagnosis of psoitis
International Nuclear Information System (INIS)
A 65-year-old woman who was diagnosed as having psoitis by CT findings, which disclosed non-symmetrical dilation of the psoas muscle and gaseous image. Pus from the psoas muscle seen at surgery corresponded to CT findings. Preoperative CT examination was useful in the establishment of diagnosis. (Namekawa, K.).
1984-01-01
International Nuclear Information System (INIS)
Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol ...
1989-12-15
CT evaluation of acetabular fractures
International Nuclear Information System (INIS)
The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.
1986-01-01
Computed Tomography in pulmonary cystic fibrosis
International Nuclear Information System (INIS)
This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method ...
1991-01-01
Computed tomography of the mediastinal tumor
Energy Technology Data Exchange (ETDEWEB)
Forty-one cases of mediastinal tumor examined by computed tomography were reviewed. CT findings of the mediastinal malignancy were as follows: 1) inhomogeneous density on contrast CT, 2) equivocaton of fat plane surrounding the tumor, 3) irregular margin. Benign teratoma had smooth margin and included fat or calcification density. Mediastinal seminoma was observed as a lobulated mass with no calcification on CT. These findings were similar to the patterns of malignant thymoma or lymphoma. Consequently, it was very difficult to differentiate between malignant thymoma and malignant lymphoma by CT. According to our data, malignant thymoma tended to expand to only one side of the anterior mediastinum and to invade the anterior chest wall. On the other hand, malignant lymphoma of anterior medistinal type expanded into the trachea and the superior ...
1984-12-01
Multislice helical CT in the diagnosis of hilar cholangiocarcinoma
International Nuclear Information System (INIS)
Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out ...
2005-11-01
CT scan findings in cerebral paragonimiasis
International Nuclear Information System (INIS)
Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).
1982-01-01
International Nuclear Information System (INIS)
To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were ...
2001-03-01
CT colonography. Virtual coloscopy; CT-Kolonographie. Virtuelle Koloskopie
Energy Technology Data Exchange (ETDEWEB)
The CT colonography or virtual coloscopy is a new diagnostic method that allows the presentation of the whole colon using minimal invasive procedures. The method allows the detection of colorectal polyps and colorectal carcinomas. The book includes the following chapters: indications for CT colonography, diagnostic procedures, data processing and interpretation, diagnostic findings, preparation of the diagnostic result description and documentation, screening.
2009-07-01
Radiologic findings of extraosseous Ewing's sarcoma
International Nuclear Information System (INIS)
The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well ...
2005-09-01
Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT
International Nuclear Information System (INIS)
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea ...
1986-01-01
CT evaulation of thoracic and abdominal fatty masses
International Nuclear Information System (INIS)
The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
To assess the malignant potential of small({<=}15mm) portal defects seen on CT arterial portography, the findings of CT hepatic arteriography and lipiodol CT were reviewed. In 91 patients who underwent both CTAP and CTHA, small portal defects were reviewed for frequency, multiplicity and location. We prospectively evauluated changes in the size and enhancement pattern of malignant lesions on follow up CT according to density on CTHA, location, lipiodol deposits on lipiodol CT, and multiplicity. Among the 91 patients, 102 small defects were defected in 42 patients(46%). Small portal defects were benign, malignant, and of undetermined malignant potential in 77%, 20% and 3% of cases, respectively. Small portal defects that were hyperattenuated on CTHA, and lipiodol deposits on lipiodol CT, were malignant in 42% and 70% of cases, ...
1999-05-01
International Nuclear Information System (INIS)
Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.
1991-01-01
Computed tomography in spinal osteoblastoma
International Nuclear Information System (INIS)
In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.
1986-01-01
Computed tomography of the acetabular fractures
Energy Technology Data Exchange (ETDEWEB)
In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or ...
1986-04-15
Computed Tomography of the spine in multiple myeloma
International Nuclear Information System (INIS)
Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray ...
1988-01-01
Computed Tomography of the complications of prosthetic surgery of the abdominal aorta
International Nuclear Information System (INIS)
Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 ...
1997-01-01
Differential diagnosis by CT units with contrast enhancement
Energy Technology Data Exchange (ETDEWEB)
Variation of CT units, in organs, before and after using contrast enhancing medium was reviewed and personal experience was presented. In the normal brain CT units was little changed by contrast enhancement (CE), whereas remarkable change was observed at lesions. No difference of CT units was observed between the normal liver and hepatomas. The normal kidney had higher CE effect than hypernephromas suggesting an increase of the sensitivity. CE was not found in cysts or necrosis. The changes of CT units in the cases of cerebral diseases are tabled with various contrast medium and scanners.
1981-04-01
Peripheral cholangiocarcinoma : three-phase helical CT appearance
International Nuclear Information System (INIS)
To analyze the enhancement patterns and morphology of peripheral cholangiocar-cinomas (CCs), as seen on three-phase helical CT. Three-phase helical CT scans of 25 cases of 24 patients with pathologically-proven CCs were retrospectively reviewed. After intravenous administration of contrast media, scans of the hepatic arterial phase (HAP) were obtained at 30 seconds, of the portal venous phase (PVP) at 70 seconds, and of the delayed phase (DP) at 3 minutes. Linear, dense, marginal enhancement was seen in 17 CCs (68%), mainly on HAP images (64%) while thick, band-like, peripheral enhancement was seen in 18 (72%), on either PVP (52%) or DP (44%). Internal enhancement was observed in 23 CCs (92%) on PVP (68%) and/or DP (88%), and 19 CCs (76%) among them showed incomplete enhancement of stippled and/or septated patterns. Most (76%) were seen throughout all three phases to be hypoattenuating, as compared to the surrounding ...
1997-08-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were ...
2001-06-01
Energy Technology Data Exchange (ETDEWEB)
To illustrate frequently encountered anatomic variations on PNS computed tomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The ...
1994-09-15
International Nuclear Information System (INIS)
To illustrate frequently encountered anatomic variations on PNS computed tomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second ...
1994-09-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to ...
2006-11-15
CT findings of foreign bodies in the chest: a pictorial essay
Energy Technology Data Exchange (ETDEWEB)
The most common causes of tracheobronchial foreign bodies are peanuts in children, and meat and dentures in adults. The most common causes of esophageal foreign bodies are coins in children and meat in adults. It is passable to diagnose a foreign body by visualization on a chest radiograph, if the foreign bodies are radio opaque. However, if the foreign bodies are radiolucent and the patients do not remember the history of aspiration, it is important to evaluate CT findings for foreign bodies and their complications. We describe the CT findings of various thoracic foreign bodies in children and adults.
2008-05-15
International Nuclear Information System (INIS)
Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations ...
2007-01-01
MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT
International Nuclear Information System (INIS)
Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T_2-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high ...
2001-04-01
Paroxysmal nocturnal hemoglobinuria: a case report of MR, CT findings
Energy Technology Data Exchange (ETDEWEB)
Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2 weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional hemosiderosis of liver.
1995-10-15
CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia
International Nuclear Information System (INIS)
Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.
1999-04-01
Facet joint injuries in acute cervical spine trauma : evaluation with CT and MRI
Energy Technology Data Exchange (ETDEWEB)
To evaluate injury patterns of facet joints and associated soft tissue injuries in patients with acute traumatic cervical facet joint injuries. From among patients with cervical spine trauma, 27 with facet joint injuries, as seen on CT and MRI, were chosen for this study. CT scans were analyzed with regard to the location of facet joint injury, the presence or absence of facet dislocation or fracture, and other associated fractures. MR images were analyzed with regard to ligament injury, intervertebral disc injury, intervertebral disc herniation, and spinal cord injury. The most common location of facet joint injury was C6-7 level(n=10), followed by C5-6(n=8). Among these 27 patients with facet joint injuries, 12(44%) had bilateral injuries and 15(56%) unilateral injuries. Facet fractures were present in 17 cases(63%) and the fracture of inferior facet was more frequent than superior. Patterns of fracture were vertical, transverse, or ...
1999-05-01
Energy Technology Data Exchange (ETDEWEB)
Macrocephaly was defined as a head measuring larger than 98th percentile. We have evaluated CT findings and head growth curves in 25 infants with large heads. Ten (40%) of 25 infants with large heads were normal developmentally and neurologically. Five (20%) of those were mentally retarded. The other 10 infants (40%) included hydrocephalus (4 cases), malformation syndrome (3 cases), brain tumor (1 case), metabolic disorder (1 case) and degenerative disorder (1 case). Their head growth curves were typed as (I), (II) and (III): Type (I) (excessive head growth curve to 2 SDs above normal); Type (II) (head growth curve gradually approached to 2 SDs above normal); Type (III) (head growth curve parallel to 2 SDs above normal). Ten of macrocephaly with normal psychomotor development were studied clinically and radiologically in details. They were all male. CT pictures of those showed normal or various abnormal ...
1982-01-01
CT of blunt chest trauma in children
Energy Technology Data Exchange (ETDEWEB)
While trauma is still the leading cause of death in the pediatric age range, it is surprising how little the CT appearances of pediatric chest injury have been investigated in the literature. We have reviewed the CT findings of blunt chest trauma in 44 children for whom chest CT examinations were requested to investigate the extent of intrathoracic injury. We noted a propensity for pulmonary contusions to be located posteriorly or posteromedially, and for them to be anatomically nonsegmental and crescentic in shape. This is possibly attributable to the relatively compliant anterior chest wall in children. The CT appearances of other major thoracic injuries are described, including pulmonary lacerations, pneumothoraces, malpositioned chest tubes, mediastinal hematomas, aortic injury, tracheobronchial injury, hemopericardium, and spinal injuries with paraspinal fluid collections. ...
1993-03-01
Tracheal cross-sectional area in children: CT determination
Energy Technology Data Exchange (ETDEWEB)
A computer method that calculates tracheal cross-sectional area by compensating for partial volume averaging was developed and validated in a study with phantoms. The program was then used to determine the tracheal cross-sectional area of 30 normal children who ranged in age from four months to 18 years. CT-derived cross sections were correlated with age, height, weight, and body-surface area, and they were compared with findings of published clinical and post-mortem studies. CT cross-sectional areas ranged from 20 to 275 mm/sup 2/, varied by as much as 22% at the three different tracheal levels studied, and appeared to correlate most closely with body height. CT-derived tracheal cross-sectional areas are quite similar to those in published reports of postmortem and clinical studies. Measurements of tracheal cross section by CT may prove useful in quantitating tracheal compromise by ...
1983-10-01
Subdural effusions in children under two years. Clinical and computer-tomographical data
Energy Technology Data Exchange (ETDEWEB)
We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 ...
1980-05-01
CT in the study of thoracic-pulmonary complications after liver transplantation
International Nuclear Information System (INIS)
In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the ...
2000-12-01
CT findings of malignant lymphoma of the anterior mediastinum. Differentiation from invasive thymoma
Energy Technology Data Exchange (ETDEWEB)
CT findings were compared retrospectively between 9 cases with malignant lymphoma of the anterior mediastinum and 8 cases with invasive thymoma. CT findings of malignant lymphoma were as follows: (1) The majority of the tumors were bilateral and extended beyond the anterior mediastinum to the other mediastinum compartments. (2) Their margin was either smooth or lobulated. (3) Their density was either homogeneous or heterogeneous. In the case with heterogeneous density, ring, triangle and/or band-like low density areas, just like interspace of fused lymph nodes, were demonstrated. Calcification or cysts could not be shown. (4) Patent inherent vessels without deviation were occasionally demonstrated running through the tumors. (5) The tumors faced and contacted widely to anterior chest wall and often pressed the lung laterally at the anterior parietomediastinal pleural reflection. (6) Pleural implants ...
1989-04-01
Thin-Section CT findings of lung small peripheral adenocarcinoma detected by CT physical examination
Energy Technology Data Exchange (ETDEWEB)
Subjects were 18 cases with adenocarcinoma of 20 mm or less in diameter, which were detected and resected surgically from September, 1993 to August, 1998. On these cases, thin-Section CT (TSCT) images were compared with pathological findings. Patients were 15 men and 3 women, with mean age of 63.4-year-old. An average tumor size was 11.5 mm (5-17 mm). According to pathological classification of Noguchi, type A as in 6 cases, type B in 3, type C in 7 and type F in 2. TSCT was carried by vas voltage =150 kVp, vas current =200 mA, beam width =2 mm, WW =2000 HU, and WL =-700 HU. The ratio of CT attenuation value in cancer by TSCT correlated with the ratio of aeration rate in the pathologic specimen. The cases of 30% or less on the ratio of CT attenuation value were 100% in types A and B, and 71% in type C. These results suggested that it is necessary to devide into two type in group of type C and the ratio ...
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).
1994-09-01
International Nuclear Information System (INIS)
Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.
1999-04-01
Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions
International Nuclear Information System (INIS)
Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, ...
1988-01-01
Pelvic CT for the prognostic evaluation of anorectal malformation
International Nuclear Information System (INIS)
The anatomical patterns of anorectal malformations have so far been studied according to the principles which inspire Pena's technique for the surgical treatment of anorectal anomalies. Thus, the diagnostic study of anorectal malformation has by the authors been considered a work of classification, but of identification. Among the diagnostic procedures in use in author's Institute, preoperative CT of pelvis is performed to assess the presence and to define the development of muscular sphincteric structure towards prognostic evaluation of continence, the major long-term goal. Seven patients, aged 1-30 months, with anorectal anomalies were studied with preoperative CT of the pelvis. CT scans showed well-developed sphinteric muscles in 3 patients (2 with recto-ureteral and 1 with recto-vestibular fistulas), poorly-developed muscular structure in 3 patients (with recto-vaginal, cloacal and prostatic fistulas), absence of ...
1989-01-01
Small lung neoplasms with growing attitude of alveolar lining. CT-pathologic correlation
Energy Technology Data Exchange (ETDEWEB)
The article correlates CT and pathologic findings in 25 lung nodules with ground glass attenuation, which are small than 2 cm in diameter. They includes adenocarcinomas (Noguchi's classification type A, B, C) and a typical adenomatous hyperplasia. (author)
2000-01-01
Diagnosis of Ewing's sarcoma in the thoracic spine - problems in differential diagnosis
International Nuclear Information System (INIS)
Spinal Ewing's sarcomas are rare and cause problems in differential diagnosis. The radiologic, nuclear medicine and CT findings in two children with histologically proven Ewing's sarcoma are presented and problems in differential diagnosis discussed. Biopsy should be done early. (orig.).
Childhood neuroborreliosis: clinicoradiological correlation
Energy Technology Data Exchange (ETDEWEB)
We report the cranial CT and MRI findings in three children with Lyme disease (neuroborreliosis). The neuroimaging findings in children have been rarely reported. We found cranial MRI far superior to cranial CT. Ring-enhancing lesions have been described in acute disseminating encephalomyelitis and multiple sclerosis but not in neuroborreliosis. Although other infectious and inflammatory diseases cannot be excluded, Lyme disease should be included in the differential diagnosis and put forward as being the most likely diagnosis in the appropriate clinical setting. Gadopentetate dimeglumine is helpful in assessing the response to antibiotic treatment. (orig.)
1995-10-01
CT colonography and cost-effectiveness
Energy Technology Data Exchange (ETDEWEB)
CT colonography (CTC) is increasingly advocated as an effective initial screening tool for colorectal cancer. Nowadays, policy-makers are increasingly interested in cost-effectiveness issues. A number of studies assessing the cost-effectiveness of CTC have been published to date. The majority of findings indicate that CTC is probably not cost-effective when colonoscopy is available, but this conclusion is sensitive to a number of key parameters. This review discusses the findings of these studies, and considers those factors which most influence final conclusions, notably intervention costs, compliance rates, effectiveness of colonoscopy, and the assumed prevalence and natural history of diminutive advanced polyps. (orig.)
2008-11-15
Computed tomography of the mediastinal lesion
Energy Technology Data Exchange (ETDEWEB)
Authors retrospectively analyzed the CT findings of mediastinal lesions in surgically or clinically confirmed 37 cases at Kosin Medical College during recent 4 years from September 1979 to August 1983. 1. Among 37 caes, malignant lymphoma were 7 cases, thymoma and vascular lesion or anomaly were 5 cases respectively, benign teratoma and tuberculous mediastinal lymphadenitis and neurogenic tumor were 4 cases respectively, pericardial cyst were 2 cases, bronchogenic cyst, non-specific cyst, pancreatic pseudocyst, mesothelioma, Bochdalek hernia was 1 case respectively. 2. The sex ratio between male and female was about 1 : 1 and the majority of the patients with malignant lymphoma and teratoma was under 20 years old. 3. CT findings of the each mediastinal lesion. 1) Primary mediastinal malignant lymphoma. (1) A large, matted, continuous and midline-crossing mass was observed in the ...
1984-09-15
International Nuclear Information System (INIS)
Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the ...
Role of MRI in the diagnostic evaluation of parotid diseases
International Nuclear Information System (INIS)
MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Aim of the work was to describe computerised tomography (CT) findings of calcified renal metastases focusing on differential diagnosis problems. Abdominal CT scans of 8000 patients with tumor, performed from 1984 to 1998, have been retrospectively reviewed. [Italian] Scopo del lavoro e' quello di descrivere gli aspetti con tomografia computerizzata delle metastasi renali calcificate enfatizzando le problematiche diagnostico differenziali. Sono state valutate retrospettivamente le indagini TC addominali di 8000 pazienti affetti da tumore nel periodo 1984-1998, analizzando le lesioni calcificate riscontrate.
2000-03-01
International Nuclear Information System (INIS)
To assess the clinical and pathologic features of each type of intrahepatic cholangiocarcinoma, which is divided into three types according to gross appearance, and to determine the efficacy of CT in detecting this tumor. The pathologic and CT features of 53 surgically proven cases of intrahepatic cholangio-carcinoma were reviewed. On the basis of their gross appearance, the tumors were divided into three types, as follows : mass forming (n=33), periductal infiltrating (n=6), and intraductal growth type (n=14). CT scans were analyzed for sensitivity of detection and correlation between a tumors appearance and its histopathology. The most common histopathologic feature of mass forming and periductal infiltrating type was tubular adenocarcinoma, while in the intraductal growth type, papillary adenocarcinoma (100%) was common. With regard to pattern of tumor spread, intrahepatic and lymph node metastasis were more common in ...
1999-05-01
Focal lesions in external auditory canal: computed tomography images
International Nuclear Information System (INIS)
To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC ...
Transcatheter internal radiotherapy of hepatoma using radioactive iodized oil (I-131 Lipiodol)
Energy Technology Data Exchange (ETDEWEB)
The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest ...
1988-04-01
International Nuclear Information System (INIS)
To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response ...
Energy Technology Data Exchange (ETDEWEB)
Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed ...
2000-09-01
Intrasphenoid cephalocele: MRI in two cases
Energy Technology Data Exchange (ETDEWEB)
The intrasphenoid form of basal cephalocele is uncommon. We describe the clinical, CT and MRI findings in two cases presenting in middle age with persistent cerebrospinal fluid rhinorrhoea. Emphasis is placed upon the imaging findings which aid in discrimination of intrasphenoidal cephalocele from more common causes of a sphenoid sinus mass. (orig.)
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
Between October 1990 and March 1991, 8 patients with cystic lesions in the region of the posterior bladder wall, the seminal vesicles and the prostate were examined by MRI. In all cases there was accurate characterisation of the lesion and of its anatomy. In 3 patients with abnormalities in the retrovesical space there was very good agreement with the operative findings. 4 patients were treated conservatively. In these patients there was good agreement with the findings on cystoscopy, CT and sonography. (orig.).
1992-07-01
Cardiac transplantation. Value of computed tomography
International Nuclear Information System (INIS)
In 9 over 12 patients who underwent cardiac transplantation computed tomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.
1986-01-01
Reevaluation of the 'Falx sign'
Energy Technology Data Exchange (ETDEWEB)
Visualization of falx cerebral on non-enhanced computer tomography (CT) of children with severe head injuries (the falx sign) has been regarded as an evidence of subarachnoid hemorrhage. On the contrary, other authors have reported reverse results. To evaluate clinical significance of the falx sign, authors studied frequency of visualization and CT number of falx cerebri and dural sinuses in 65 children with head injury and 65 children without head injury examined by cranial computer tomography at the Department of radiology, St Paul's Hospital, Catholic Medical College from March to September, 1981. All patients with head trauma were studied within 1 week of the traumatic event. Visualization of falx cerebri was observed at slice in the region of lateral ventricle and slice near to vertex respectively. On the slice in the region of lateral ventricle, falx cerebri was identified in 82% of all of the children ...
1982-06-15
Energy Technology Data Exchange (ETDEWEB)
Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T{sub 2}-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often ...
2001-04-01
Effect of pressure on iodine complexes, 2
International Nuclear Information System (INIS)
Absorption spectra of the CT bands of I_2 complexes with Et_2O, Et_2S, and Et_2Se in heptane have been measured up to 4400 bar at 25"0C. The equilibrium constants and the volume changes accompanying complex formation, and the molar extinction coefficients and absorption maxima have been estimated. The volume changes were comparable with those estimated by the visible I_2 bands and by the X-ray data of the I_2 complexes in the crystalline state. In the CT bands of Et_2S-I_2 and Et_2Se-I_2 complexes inversion of shift from red to blue has been observed with increasing pressure though the CT band of Et_2O-I_2 complex shifted only through red. This inversion appears to be characteristic of the strong CT complex. Enhancement of the molar extinction coefficient of the CT band has been found with increasing pressure suggesting enhancement of the CT ...
1979-01-01
CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis
International Nuclear Information System (INIS)
To assess the CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis. The CT features of 26 patients with cholangiocarcinoma and hepatolithiasis were reviewed and compared with those of 23 patients with intrahepatic stones alone, acting as control subjects. CT findings were analyzed for tumor appearance and adjacency to hepatolithiasis. We studied clinical findings, noting the presence or absence of wall thickening or soft tissue attenuation within the bile duct, the luminal diameter of dilated bile duct, and the presence of periductal enhancement, and compared these with the findings for control groups. CT images of the tumor revealed a hepatic low-attenuating mass with peripheral rim enhancement(n = 14,54 %), or periductal thickening, or low-attenuating lesions in segmental dilatation of ...
1999-09-01
Spectrum of abdominal pathologies detected with CT in long term dialysis patients
Energy Technology Data Exchange (ETDEWEB)
As a consequence of the expanded use of long term hemodialysis and continuous ambulatory peritoneal dialysis (CAPD) treatments and extended life spans, complications of end-stage renal disease and dialysis treatments are being encountered with increasing frequency in these patients. Computed tomography can accurately depict many of the potential complications of end-stage renal disease on dialysis. This article presents the abdominal CT findings of 429 end-stage renal disease patients who are on either hemodialysis or continuous ambulatory peritoneal dialysis treatment.
2009-11-15
Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings
International Nuclear Information System (INIS)
Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In ...
2000-12-01
Brain CT image and handedness of schizophrenia
International Nuclear Information System (INIS)
Brain CT images were reviewed of 98 schizophrenic patients and 90 healthy persons in relation to handedness and aging. CT images were further reconstructed to examine morphologically subtle changes in each region. Schizophrenic patients had progressive brain atrophy and dilated lateral ventricles, especially on the left side and in the posterior part of the lateral ventricle. These findings were more marked in left-handed than in right-handed schizophrenic patients. According to age groups, there were significant differences between schizophrenic and normal persons over the age of 40. The incidence of left handedness was significantly higher in schizophrenic patients in their fourties than the age-matched normal persons (31.4% vs 15.1%). Morphological abnormality and laterality might be due to the same pathologic consequences. (N.K.).
International Nuclear Information System (INIS)
Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs.
International Nuclear Information System (INIS)
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
1999-01-01
Aortic non communicating dissections. A study with helical CT
International Nuclear Information System (INIS)
The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo ...
2000-09-01
Energy Technology Data Exchange (ETDEWEB)
(1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on ...
2007-02-15
Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences
Energy Technology Data Exchange (ETDEWEB)
To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdominal and intermediate window) and three-dimensionally (manually and semi-automatically). Linear mixed models were used to assess the variability and systematic differences between CT colonography and optical colonoscopy techniques. The variability of forceps and linear probe measurements was comparable and both showed less variability than measurement by visual assessment. Measurements by linear probe were 0.7 mm smaller than measurements by visual assessment or by forceps. The variability of all CT colonography techniques was lower than for measurements by forceps or visual assessment and ...
2010-06-15
International Nuclear Information System (INIS)
Active contrast material extravasation can be recognized with conventional CT scanners, though it has been considered a rare finding. Helical CT seems to increase the detection rate and especially to boost the radiologist's confidence in this diagnosis. Though active bleeding is defined in severely-injured subjects requiring urgent intervention and may be associated with findings of hypovolaemic shock, it should not be considered itself as a negative prognostic factor. Contrast extravasation is due to ongoing hemorrhage and its detection is critical for urged treatment. Accurate anatomical location permits to choose surgical management or transcatheter embolization and thus decreases time consumption for precis e bleeding site identification.
1999-03-01
Energy Technology Data Exchange (ETDEWEB)
Our purpose was to investigate the usefulness of Lipiodol-CT for detection of residual viable neoplastic tissue in hepatocellular carcinoma (HCC) lesions treated by means of percutaneous ethanol injection (PEI). An emulsion of 5 to 20 ml iodized oil and 50 to 70 mg doxorubicin hydrochloride was intraarterially injected in 18 patients with 25 HCC lesions treated by means of PEI one to 24 months before. At CT performed 3 to 5 weeks after injection, retention of Lipiodol was observed in 9 of 13 tumors that still contained viable neoplastic tissue and in 2 of 12 tumors proven to have undergone complete necrosis after PEI. The sensitivity and specificity of Lipiodol-CT were 69.2% and 83.3%, respectively. Thus, Lipiodol-CT seems to have limited diagnostic value after PEI, probably as a consequence of the alcohol-induced vascular damage, accounting for both false-negative and ...
1994-07-01
Le leucodistrofie: aspetti clinici e quadri con Tomografia Computerizzata e con Risonanza Magnetica
International Nuclear Information System (INIS)
Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the ...
1991-01-01
International Nuclear Information System (INIS)
CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to ...
2003-03-01
A study on brain CT of neurological endemic cretinism
International Nuclear Information System (INIS)
A study on brain CT was made in 20 cases of typical endemic cretinism and 15 cases of normal persons. These patients from severely iodine deficient area were diagnosed as neurological endemic cretinism characterized by severe mental retardation with impairment of hearing, speech, neuromotor, etc. to varying degrees. The brain CT showed that there were many and deep depressions in cerebral cortex, especially in frontal and parietal lobes of some cretins, the lateral ventricle system was dilated, particularly in posterior part of it, and the interhemisphere fissure, lateral fissure and subarachnoid cisterns were also expanded. The CT value of cortex was higher and white matter was lower than that of normal persons. In some severe cases, the two hemispheres of brain were not the same in size. These findings above indicated that these endemic cretins had a severe retardation of brain development including ...
Evolution of virtual CT laparoscopy for preoperative imaging in laparoscopic cholecystectomy
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to determine the feasibility of virtual endoscopy, named as ''virtual CT laparoscopy'', in the hepatobiliary system prior to laparoscopic cholecystectomy. We applied this technique to 28 patients suspected of having biliary disease. These images were compared and analyzed qualitatively based on visualization of the structures critical to operative cholangiography and surgical findings. Twenty-four patients, who underwent laparoscopic cholecystectomy, were evaluated as follows: the common bile duct and the hepatic duct were adequately visualized in 23 (96%) of the 24 patients, the cystic duct in 21 (88%), the gallbladder opacification in 20 (83%), the liver inferior surface in 20 (83%). Four patients had anatomic variations detected virtual CT laparoscopy and were proven by operative cholangiography and surgical findings. We emphasize that ...
2002-06-01
Cholangiocarcinoma associated with recurrent pyogenic cholangitis: sonographic and CT findings
International Nuclear Information System (INIS)
Cholangiocarcinoma may be associated with recurrent pyogenic cholangitis as a complication of longstanding proliferative cholangitis in the presence of intrahepatic stones. Sonographic and CT findings of six patients with cholangiocarcinoma of the liver associated with recurrent pyogenic cholangitis are presented. The cases were among 128 patients who underwent partial resection of the liver because of recurrent pyogenic cholangitis and its complication. On sonogram the mass was depicted in four patients as an ill-defined heterogenously echogenic mass and in one patient as a bulging contour; in the remaining one case the mass was not detected. There were small or large, shadowing or non shadowing stones within the tumor in five cases. In one case, the stone was in the duct proximal to the tumor. On CT scans of four patients, the tumors were depicted as an ill-defined, irregular low attenuation masses with variable contrast ...
1992-01-01
Computerized tomography of adrenal glands in the investigation of Cushing's syn
International Nuclear Information System (INIS)
Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author).
The Growth of an Extrapancreatic Solid Pseudopapillary Tumor from the Greater Omentum: A Case Report
Energy Technology Data Exchange (ETDEWEB)
A solid pseudopapillary tumor is an uncommon tumor of the pancreas that rarely metastasizes to other organs and usually shows good prognosis. An extrapancreatic tumor arising from a solid pseudopapillary tumor is very rare. We report a case of an atypical extrapancreatic solid pseudopapillary tumor that arose from the great omentum and disseminated to the peritoneum, and discuss the radiologic findings, including the CT, US, and MRI.
2010-01-15
The Growth of an Extrapancreatic Solid Pseudopapillary Tumor from the Greater Omentum: A Case Report
International Nuclear Information System (INIS)
A solid pseudopapillary tumor is an uncommon tumor of the pancreas that rarely metastasizes to other organs and usually shows good prognosis. An extrapancreatic tumor arising from a solid pseudopapillary tumor is very rare. We report a case of an atypical extrapancreatic solid pseudopapillary tumor that arose from the great omentum and disseminated to the peritoneum, and discuss the radiologic findings, including the CT, US, and MRI
2010-01-01
Computed tomography of intrahepatic cholangiocarcinoma
International Nuclear Information System (INIS)
Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).
Computed tomographic findings of intrahepatic peripheral cholangiocarcinoma
International Nuclear Information System (INIS)
Cholangiocarcinoma is synonymous with bile duct carcinoma, and can originate in a small intrahepatic bile duct (peripheral type), a major intrahepatic duct including the hepatic hills, an extrahepatic duct, or near the papilla of Vater (central type). In a sense bile duct carcinoma of the peripheral type is cholangiocarcinoma of the liver; it has the same gross configuration as hepatocellular carcinoma, resulting in difficulty to differentiate on the CT. The authors studied CT findings of 14 cases of pathologically proven peripheral type cholangiocarcinoma of the liver during the last 4 years. The results were as follows: 1. Of 14 cases, 8 were female and 6 were male, and the age ranged from 5th to 7th decades. 2. Preoperative clinical diagnosis were as follows: hepatoma 8 cases, abscess 5 cases and metastasis 1 case in order of frequency. 3. Diagnosis were confirmed by hepatic lobectomy in 7 cases, wedge resection in 5 ...
1986-08-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: In the present study the reduction of artifacts using an extended CT scale technique was examined in 5 vitallium and 5 titanium-aluminium-vanadium tumor prostheses. Methods: 5 titanium-aluminium-vanadium and 5 vitallium distal femur Mutars {sup trademark} tumor prostheses (Mutars {sup trademark} - Modular Universal Tumor And Revision System) were implanted in 10 human femur specimens. 110 artifical drill hole lesions of 1 mm, 2 mm, 3 mm, 5 mm and 8 mm diameter were placed in the bone around the hexagonal stem of the tumor prosthesis and furthermore in the proximal part of the femur. All specimens were examined using conventional CT and an extended CT scale technique in a slice thickness of 3 mm. Results: In the proximal part of the femur all drill holes could be detected using 3 mm slices, no artefacts were observed. Along the hexagonal stem smooth lines arising from each hexagonal plane could ...
2001-12-01
the earth observer - Earth Observing System - NASA
of satellite, aircraft and ground-based observations. In ..... swarm traps by Utah Department of Food and Agriculture (DAF) personnel. Preliminary Results ..... the 150th anniversary of the book's publication and the 200th anniversary of Darwin's birth. ...... cold war submarine missions to find that Arctic Ocean ...
Intrahepatic peripheral cholangiocarcinoma; dynamic features of CT scans
International Nuclear Information System (INIS)
To elucidate the dynamic features of CT scans in peripheral cholangiocarcinoma for the differentiation of this tumor from various primary hepatic neoplasms. Materials were 24 cases of pathologically confirmed peripheral cholangiocarcinoma. Contrast enhancement patterns of central and peripheral portion of the masses were analyzed at three phases including arterial dominant(22), tissue equilibria(24), and postequilibria(9). Other associated CT findings and laboratory data were analyzed. Serum total bilirubin was mostly below 2 mg/dl(22/24), hepatitis B surface antigen was positive in only 9%, serum alphafetoprotein was elevated in 18%, carcinoembryonic antigen in 47%, cancer antigen 19-9 in 60%. In the arterial dominant image(22), 50% of the cases showed peripheral hyperdensity and 50% total hypodensity. In the tissue equilibrial images(24), 63% showed total hypodensity, 25% peripheral hyperdensity, and 13% total isodensity. ...
1995-05-01
AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography
International Nuclear Information System (INIS)
Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases ...
2000-06-01
Computed tomography whole body imaging in multi-trauma: 7 years experience
International Nuclear Information System (INIS)
AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all ...
2006-04-01
Energy Technology Data Exchange (ETDEWEB)
Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto ...
1999-04-01
Energy Technology Data Exchange (ETDEWEB)
The usefulness of helical CT early phase images optimized by the SmartPrep method for evaluation of wall invasion by colorectal cancer was investigated. Between August 1997 and September 1998, CT was performed to evaluate the primary tumor and local extension in 10 consecutive patients with colorectal cancer confirmed by barium enema- and/or colonoscopy. Early-phase images were acquired by using SmartPrep application software. This method allows the optimal scan delay time to be obtained by continuous monitoring of increases in CT values after injection of contrast medium. Sections of the surgical specimens, close to the same plane as the CT images, and of the same slice thickness, were analyzed histopathologically. All 10 cancers, regardless of size, showed strong enhancement on the early-phase images (81.4-112 HU, mean: 95.1 HU). The strongly enhanced image areas on CT ...
2000-02-01
Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology
Energy Technology Data Exchange (ETDEWEB)
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
1994-02-01
International Nuclear Information System (INIS)
Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and ...
2005-03-01
Geosynchronous orbit magnetopause crossings
Energy Technology Data Exchange (ETDEWEB)
In this study we extend the analysis of magnetopause crossings observed with Magnetospheric Plasma Analyzer measurements to examine a much larger statistical data set. This study examines 39 maiznetosheath/LLBL intervals from 79 spacecraft-months of observations: these observations were taken from a survey of data from the start of each spacecraft mission and extending through March 1993. In contrast to the previous findings, we find no evidence for a significant dawn/dusk asymmetry in geosynchronous magnetopause crossings.
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
Purpose of this item is to report the CT patterns of pancreatic mesenchymal lesions and to investigate the capabilities and limitations of this technique in terms of characterization. In selected cases, CT can provide virtually diagnostic information (lipoma and teratoma), or at least highly suggestive findings (NHL, plexiform neurofibroma, lymphangioma). Moreover, knowledge of the variable morphostructural patterns of mesenchymal hisototypes (SCH, Sarcoma etc.) permits to include them in the differential diagnosis of pancreatic masses. [Italian] Scopo di questo rapporto e' descrivere gli aspetti semeiologici dei tumori mesenchimali del pancreas con la TC verificandone le possibilita e i limiti per la caratterizzazione. Pur nella rarita' dei reperti considerati, la TC puo' consentire l'effettiva caratterizzazione in alcuni casi (lipoma, neurofibroma plessiforme, linfangioma) o includere ...
1999-10-01
Computed tomography of the chest in the postoperative recurrences of bronchogenic carcinoma
International Nuclear Information System (INIS)
The authors describe the different types of postoperative carcinoma recurrences, as seen on CT examinations of the chest, in 38 patients who underwent different surgical procedures for bronchogenic carcinoma (12 pneumonectomies, 22 lobectomies, 2 segmentectomies, and 2 atypical resections). The recurrences were classified as follows: 1) recurrence in the bronchial stump; 2) limph node enlargement; 3) recurrence in the thoracic wall; 4) recurrence in the residual lobe; 5) pleural effusion; 6) nodule in the contralateral lung. The CT findings, Correlated with those from plain chest radiographs and clinical simptoms, indicate a higher incidence of recurrences in the hilar region, either in the bronchial stump or as node after total and subtotal resection are separately analyzed. While after pneumonectomy plain chest radiographs fail to demonstrate the recurrence in most cases, so that CT is nearly always ...
1990-01-01
International Nuclear Information System (INIS)
Ischemic bowel disease is a rare disorder whose incidence is increasing as the mean age of the population increases. Diagnosis by clinical, laboratory and radiologic means is often difficult, and delay in definitive therapy results in substantial morbidity and mortality. A series of 26 consecutive patients, with proved acute superior mesenteric ischemia, was retrospectively reviewed: the authors reports the diagnostic methods performed preoperatively, the site and the cause of infarction and the time passed between the first radiograph and surgery. Plain abdominal radiographs were performed in 25 of 26 patients, screening abdominal US in 23 cases and CT in 19 cases. All radiological examinations were retrospectively reviewed by the three authors, independently, to recognize the different signs of infarction. On plain abdominal films, the findings warranting a presumptive diagnosis of bowel infarction were air-fluid levels (84% of cases), ...
1997-01-01
The Spectrum of Fundus Autofluorescence Findings in Birdshot Chorioretinopathy
UK PubMed Central (United Kingdom)
Objective. To describe the diverse patterns observed with the use of autofluorescence fundus photography (FAF) in patients with Birdshot chorioretinopathy (BSCR). Methods....Full Text Available
2009-01-01
Periodontal disease and spontaneous preterm birth: a case control study
UK PubMed Central (United Kingdom)
BackgroundSeveral studies have suggested an association between periodontal disease and prematurity but this finding has not been consistently observed.MethodsCase...Full Text Available
This study examined preliminary psychometric properties of the Teaching Practices Observation Scale (TPOS), a newly developed observational taxonomy for assessing teacher behaviors during free play with young children. Behaviors of 42 child caregivers and junior kindergarten teachers were coded using a combination of time-sampling, event-sampling, and behavior ratings. Findings support the validity of observational coding scheme. (Author/KB)
1998-12-01
Energy Technology Data Exchange (ETDEWEB)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray ...
1995-03-11
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray ...
1995-03-01
Energy Technology Data Exchange (ETDEWEB)
Clinical information is indispensable for swift and cost-effective clarification of diseases of the larynx. While quality clarification of neurological changes in the area of the posterior cranial fossa and in the course of the vagus nerve as a cause of glottis malfunction is possible with MRI, localized disease of the larynx can more effectively be assessed with low-artifact CT. In the particularly difficult assessment of the post-operative larynx, a recurrence can be diagnosed only after a baseline study has been carried out after the end of therapy. With knowledge of the pretherapeutic findings, the findings immediately post-therapy, and the operation technique used, the optimal CT examination, which can be carried out quickly, will be able to provide more information about recurrence. (orig.) [Deutsch] Zur schnellen und kostenguenstigen Abklaerung von Erkrankungen des Larynx ist die klinische ...
1998-02-01
Preoperative staging of rectal carcinoma with combined sonography and pelvic computed tomography
International Nuclear Information System (INIS)
The accurate staging of rectal carcinoma is very important for treatment planning. The histological data obtained from surgical specimens of 22 patients with rectal carcinoma were compared with pre-and postoperative endorectal US findings and with preoperative CT results. According to an adapted version of Astler and Coller classification, the different degrees of tumor spread into the rectal wall were represented as follows: stage A: 1 patient; stage B1: 5 patients; stage B2: 6 patients; stage C1: 1 patient; stage C2: 8 patients and stage D: 1 patient. Preoperative staging, based on the overall results of CT and US, was in agreement with histology in 19 of 22 cases. Individual analysis of US and CT results, in comparison with histological data, showed US staging accuracy to be 77.3% (17/22 patients). US accuracy in demonstrating tumor spread into the rectal wall (stages A, B1, C1) was 100% (7/7 ...
1991-01-01
Computed tomography in the diagnosis of cavum septum pellucidum
Energy Technology Data Exchange (ETDEWEB)
The cavum septum pellucidum is an anatomical variants of the septum pellucidum, and lying between two lateral ventricles and this is referred to as the fifth ventricle. Occasionally, posterior extension of the cavum septum pellucidum towards the splenium is seen and this is known as the cavum vergae, or sixth ventricle. The septum is double membrane and occasionally a narrow cavity containing CSF is present between these membrane. The roof of the cavum septum pellucidum is formed by the corpus callosum and its floor by the anterior pillars of the fornix. This cavum outlined with air is occasionally seen in the pneumoencephalography. Brain CT scans of 1000 patients were performed, and the diagnosis could be made on the basis of the characteristic shape, density and location. Other diagnostic procedure are not necessary in these cases. Patients were examined with CT scanner from June-80' to Dec-80', at department of radiology, ...
1981-09-15
Energy Technology Data Exchange (ETDEWEB)
The extent measurement error on CT colonography influences polyp categorisation according to established management guidelines is studied using twenty-eight observers of varying experience to classify polyps seen at CT colonography as either 'medium' (maximal diameter 6-9 mm) or 'large' (maximal diameter 10 mm or larger). Comparison was then made with the reference diameter obtained in each patient via colonoscopy. The Bland-Altman method was used to assess agreement between observer measurements and colonoscopy, and differences in measurement and categorisation was assessed using Kruskal-Wallis and Chi-squared test statistics respectively. Observer measurements on average underestimated the diameter of polyps when compared to the reference value, by approximately 2-3 mm, irrespective of observer experience. Ninety-five ...
2006-08-15
Energy Technology Data Exchange (ETDEWEB)
CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both ...
1997-04-01
International Nuclear Information System (INIS)
CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both ...
1997-01-01
Feature-based rectal contour propagation from planning CT to cone beam CT
UK PubMed Central (United Kingdom)
The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available
2008-10-01
[Computed tomography in gunshot trauma. I. Ballistics elements and the mechanisms of the lesions].
The knowledge of wound ballistics and of wounding mechanisms is mandatory for the radiologist to interpret the CT findings of gunshot wounds. The severity of a bullet wound depends on the characteristics of the tissue it goes through, i.e., tissue elasticity, density, thickness of the wounded body part, the type of tissue, its specific gravity, internal cohesiveness and anatomical relationships, as well as on missile characteristics, i.e., mass, shape, fragmentation and deformation. Bullet velocity is certainly a major factor in wounding, but it is only one factor. Two major wounding mechanisms exist the crushing of the bullet-struck tissue (forming the permanent cavity) and radial stretching (forming a temporary cavity). Bullet "yaw" is defined as the angle between the long axis of the bullet and its flight path. The yaw is directly proportional to tissue crushing and stretching: the wider the yaw, the most severe tissue crushing and ...
1995-04-01
Hypoparathyroidism and intracerebral calcification in patients with beta-thalassemia major
Energy Technology Data Exchange (ETDEWEB)
Background: Hypoparathyroidism is one of the most important endocrine complications of thalassemia major. This study was conducted to evaluate the prevalence of intracerebral calcifications in patients with thalassemia with and without hypoparathyroidism. Methods: 47 beta-thalassemia patients with hypoparathyroidism underwent a brain CT scan to investigate the presence and extent of intracerebral calcification. 30 age- and sex-matched beta-thalassemic patients with normal parathyroid function who had undergone brain CT for headache, or some other minor neurologic problems were also enrolled in the study serving as controls. The amount of intracerebral calcification, hematologic parameters, and some clinical findings were compared between both groups. Results: Intracerebral calcification was present in 54.2% of beta-thalassemia patients with hypoparathyroidism. The most frequent sites of calcification were basal ganglia, and ...
2009-06-15
The luminosity function of cluster pulsars
We study luminosities of millisecond pulsars in globular clusters by fitting the observed luminosity distribution with single and double power laws. We use simulations to model the observed distribution as the brighter part of some parent distribution for Terzan 5 and try to find a model which simultaneously agrees with the observed diffuse radio flux, total predicted number of pulsars and observed luminosity distribution. We find that wide ranges of parameters for log-normal and power-law distributions give such good models. No clear difference between the luminosity distributions of millisecond pulsars in globular clusters and normal disk pulsars was seen.
2010-01-01
X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt
Energy Technology Data Exchange (ETDEWEB)
This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.
1985-03-01
Dextranomer/hyaluronic acid copolymer (Deflux) implants mimicking distal ureteral calculi on CT
Energy Technology Data Exchange (ETDEWEB)
Periureteral or subtrigonal injection of dextranomer/hyaluronic acid (Dx/HA) copolymer (Deflux, Q-Med, Uppsala, Sweden) is an increasingly common endoscopic treatment for vesicoureteral reflux. We report a confusing radiographic finding of bilateral calcified Dx/HA injections initially thought to represent bilateral distal ureteral stones in a boy who presented with intermittent periumbilical pain. Urologists, radiologists, and emergency room physicians should be aware of the potential for calcification of ureteral implants of Dx/HA, and of the potentially confusing radiographic images that may result. (orig.)
2008-01-15
Evaluation of node involvement in non small cell bronchogenic carcinoma. CT-pathology correlation
International Nuclear Information System (INIS)
The main purpose of this work is to evaluate the role of CT in identifying other morphological signs of met static lymph node involvement from non small cell bronchogenic carcinoma. This is done to improve N staging, a critical step in this disease. In fact, since diameter is the only criterion used to distinguish normal form abnormal lymph nodes, mediastinal CT only has 80% diagnostic accuracy. 137 patients with known or suspected lung cancer were examined with Helical CT during early and late arterial phases (2 min. delay, 3 mm thickness, 5 mm inter slice gap) to depict node characteristics. Mediastinal lymph nodes, located according to the American Thoracic Society mapping, were considered normal when they were not visible or, if visible, less than 1 cm in diameter and of homogeneous density; lymph nodes over 1 cm in diameter and homogenous density were considered reactive. A lymph node was considered metastatic when, ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two ...
2007-12-15
A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)
International Nuclear Information System (INIS)
T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering ...
Energy Technology Data Exchange (ETDEWEB)
With the aim of demonstrating the usefulness of computerised tomography (CT) findings in the planning of brain neurosurgery in gunshot victims, for prompt and successful treatment, 30 patients with brain gunshot wounds were examined with CT over 5 years. The mortality rate of firearm wounds of the skull base was 34% higher than that of the hemisphere; this is due to carotid hemorrhage and midbrain damage. Such traumas require emergency radiological diagnosis and neurosurgical treatment because of their severity and early irreversible complications. Complex operations and skilled surgeons may prevent disabling postoperative sequels. CT findings are indispensable and must be correctly interpreted. The radiologist and the neurosurgeon must collaborate closely and both must consider several diagnostic factors affecting surgical planning. [Italian] Scopo dello studio e' stato ...
2000-03-01
Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma
International Nuclear Information System (INIS)
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake corresponding to ...
2003-11-01
Energy Technology Data Exchange (ETDEWEB)
Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that experience and the knowledge of associated artifacts and the limitations they can impose on diagnosis are prime requirements for the implementation of such visualization techniques. (orig.) ...
2008-02-15
Energy Technology Data Exchange (ETDEWEB)
Aim of this retrospective study was to assess the capability of contrast-enhanced helical computerised tomography (CT) in sigmoid diverticulitis, especially relative to selection of the appropriate treatment. The findings of 41 patients were reviewed from 1998 to 1999 June. Contrast-enhanced helical CT is the imaging modality of choice in assessing mild or severe acute diverticulitis because it provides useful information for appropriate treatment planning in the emergency setting. This technique is most useful in questionable cases and in patients with suspected severe diverticulitis where a choice must be made between different treatment options. [Italian] Scopo di questo studio retrospettivo e' illustrare i molteplici aspetti radiologici della flogosi diverticolare sigmoidea con tomografia computerizzata (TC) spirale, con specifico riguardo alle implicazioni terapeutiche che scaturiscono dall'analisi e ...
2000-03-01
MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT
UK PubMed Central (United Kingdom)
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
2009-09-01
Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas
UK PubMed Central (United Kingdom)
AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available
2011-09-07
International Nuclear Information System (INIS)
Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented suggest that while ...
Intracranial tuberculoma: MR imaging
International Nuclear Information System (INIS)
MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially ...
1988-11-01
Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences
International Nuclear Information System (INIS)
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of ...
Energy Technology Data Exchange (ETDEWEB)
Computed Tomography (CT) and, more recently, ultrasound (US), have proved excellent tools for quantifying adipose tissue distribution. Body fat distribution is an important factor in the treatment of obesity and its complications. In this work it is investigated the correlation between CT and US measurements in pediatric obesity. Forty obese children and adolescents aged 4.1-14.8 years were submitted to CT and US. Intra-abdominal, subcutaneous and total body fat were calculated (in cm{sup 2}), with the CT image analysis software. The rectus muscle-spine and rectus muscle-aorta distances, as indicative of visceral fat thickness, were measured on US images with(out) compression. The distance between skin fat and fat-rectus muscle interfaces was measured as subcutaneous fat thickness. US-CT findings have been compared with other morphometric variables-i.e., ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better ...
1996-05-01
International Nuclear Information System (INIS)
The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
1995-09-01
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
1995-09-01
International Nuclear Information System (INIS)
Periosteal Ewing's sarcoma is an uncommon, but well documented origin of this malignant condition with radiography signs, different from intramedullary growing tumours. Imaging modalities like CT or MRI supply proof of macroscopically intact endosteal cortical surface and free medullary cavity in long bones affected by this periosteal type of malignancy. Definite confirmation is valid after a careful microscopic investigation of the resected specimen. The prognosis of this type of Ewing's sarcoma may be favourable than that of the central type. Early diagnosis and therapy are thus essential. A clinical survey of six observations is given. (orig.).
Energy Technology Data Exchange (ETDEWEB)
CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to ...
2003-03-01
International Nuclear Information System (INIS)
The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols. Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with ...
2010-12-01
UK PubMed Central (United Kingdom)
BackgroundThe aim of the present article was to evaluate whether angiogenic parameters as assessed by transvaginal color Doppler ultrasound (TVCD) may predict those prognostic factors...Full Text Available
Absolute dimensions of unevolved O type close binaries
Energy Technology Data Exchange (ETDEWEB)
A method is presented to derive the absolute dimensions of early-type detached binaries by combining the observed parameters with results of evolutionary computations. The method is used to obtain the absolute dimensions of nine close binaries. We find that most systems have an initial masss ratio near 1.
1984-03-15
International Nuclear Information System (INIS)
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only ...
1991-01-01
The Adrenal Mass: Correlation of Histopathology with Imaging
British Library Electronic Table of Contents (United Kingdom)
Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
2010-01-01
Severe paraquat poisoning: clinical and radiological findings in a survivor
International Nuclear Information System (INIS)
Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a discussion of the therapeutic algorithm for ...
Severe paraquat poisoning: clinical and radiological findings in a survivor
Energy Technology Data Exchange (ETDEWEB)
Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a discussion of the therapeutic algorithm for ...
2010-07-01
Mesenchymal stem cell transplantation for diffuse alveolar hemorrhage in SLE
British Library Electronic Table of Contents (United Kingdom)
Background. A 19-year-old girl was diagnosed with systemic lupus erythematosus, based on findings of arthritis, malar rash, positive antinuclear antibody test and high levels of antibodies to double-stranded DNA. Two months after diagnosis, the patient presented with a sudden drop in blood hemoglobin level. Several days later, she developed bloody sputum, rapidly progressive dyspnea and hypoxemia. High-resolution CT showed diffuse alveolar infiltrates in both lung fields.Investigations. Physical examination, complete blood count, erythrocyte sedimentation rate, urinalysis, 24-h urine protein excretion, fecal occult blood test, d-dimer test, acid hemolysis test, activated partial thromboplastin time and prothrombin time, direct and indirect Coombs tests, bone marrow smear, arterial blood ga...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
A 46-year-old man was referred to us after he presented to his local physician complaining of difficulty eating. Upper gastrointestinal endoscopy revealed a tumor at the esophagogastric junction (EGJ), and moderately differentiated adenocarcinoma was diagnosed from the biopsy findings. Computed tomography (CT) showed apparent enlargement of the pretracheal lymph nodes, the lymph nodes around the bilateral recurrent laryngeal nerves, and the lower thoracic paraesophageal lymph nodes, confirming metastasis. Since the disease was far advanced esophagogastric cancer with marked lymph node metastases throughout the mediastinum, curative resection would have been unlikely. Thus, he was commenced on systemic chemotherapy with cisplatin (90 mg/body, day 8) + S-1 (120 mg/body/day, given for 3 weeks...
2011-01-01
Acoustic band gaps in arrays of neutral inclusions
British Library Electronic Table of Contents (United Kingdom)
We analyse numerically the acoustic stop band properties of an array of orthotropic coated cylinders whose elastic parameters are deduced from a geometric transform [H. Chen, C.T. Chan, Acoustic cloaking in three dimensions using acoustic metamaterials, Appl. Phys. Lett. 91 (2007) 183518]. We find that whereas a single coated inclusion is acoustically neutral at any frequency, an array of them might display some stop bands. More precisely, an array of freely vibrating coated voids is always neutral, whereas an array of clamped coated inclusions might display a zero frequency stop band. Interestingly, an array of radially symmetric coated inclusions behaves as local Helmholtz resonators, for which the eigenfield within each cloak is obtained in closed form, leading to a frequency estimate a...
2010-01-01
A case of subfascial lipoma in the lateral space of neck: US and CT findings
British Library Electronic Table of Contents (United Kingdom)
Sommario I lipomi del collo e della testa in genere si verificano nel tessuto sottocutaneo superficiale. Quelli sottofasciali intramuscolari sono molto rari. Riportiamo di seguito il caso di una donna di 53 anni con un lipoma sottofasciale localizzato nello spazio antero-laterale del collo. La diagnosi della lesione e stata ottenuta con esame clinico e confermata con Ecografia (US) e Tomografia Computerizzata (TC). La lesione, caratterizzata da capsula e aspetto fibrolipomatoso, e stata escissa con intervento chirurgico.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
Purpose of this work is to evaluate the effectiveness and role of CT in blunt diaphragmatic injuries by reviewing our 8-year experience. It is reviewed the preoperative CT findings of 35 patients with surgically confirmed diaphragmatic rupture. Surgical repair was performed in the acute setting (within 12 hours of trauma) in 22 cases, and late (8 months-5 years) in 13 cases. Twenty-eight patients (80%) were examined with conventional CT and 7 (20%) with Helical CT. Of the 13 patients examined long after trauma, the left hemi diaphragm was ruptured in 12 cases (with visceral herniation in 4), and the right hemi diaphragm in 1, with no herniation. The diaphragmatic rent was found in the dome (15 cases, 43%), muscolotendinous junction (11 cases, 31%), muscular portion (8 cases, 23%), and at the muscular attachments on the ribs (1 case, 3%). As for the site of diaphragmatic injury, ...
2000-02-01
Computed tomograms of the newborn
International Nuclear Information System (INIS)
Computed tomograms (CT) from 204 cases of premature and full term infants were studied. 1) In 70 infants of hyaline membrane disease, primary apnea and asymptomatic transient hypoglycemia and hypocalcemia, without any abnormal CT findings such as intracranial hemorrhage, periventricular lucency was found in 65 cases (93%) and a wide extracerebral space of the temporal lobes was found in 60 cases (86%) before 44 weeks of gestation. A wide interhemispheric fissure was found in 11 cases of extremely premature infants before term. Periventricular lucency and a wide extracerebral space of temporal lobes may not be the result of the intracranial pathological changes, but they may represent a stage of brain development. 2) In 204 cases, intracranial hemorrhage was found in 39 cases; intra ventricular 14 cases, subependymal 2 cases, intracerebral 4 cases, subarachnoid 19 cases. CT was useful in evaluating the ...
Comparison of FDG Uptake with Pathological Parameters in the Well-differentiated Thyroid Cancer
International Nuclear Information System (INIS)
Differentiated thyroid cancer (DTC) has variable degree of F-18 FDG avidity. The purpose of this study was to evaluate the relationship between F-18 FDG uptake and pathological or immunohistochemical features of DTC. DTC patients who underwent both pre-operative F-18 FDG PET/CT scan and surgery were included in the study. Maximum standardized uptake values (SUVmax) of primary tumor were calculated. If the primary tumor showed no perceptibly increased F-18 FDG uptake, region of interest was drawn based on finding of CT portion of the PET/CT images. Pathological and immunohistochemical markers such as presence of lymph node (LN) metastasis and underlying thyroiditis, tumor size, Ki-67 labeling index, expressions of EGFR, COX-2, and Galectin-3 were evaluated. Total of 106 patients was included (102 papillary carcinomas, 4 follicular carcinomas). The mean SUVmax of the large tumors (above 1 cm) was ...
2009-02-01
CT colonography: interpretative performance in a non-academic environment
Energy Technology Data Exchange (ETDEWEB)
Aim: To investigate interpretative accuracy and reporting time for radiologists performing computed tomography (CT) colonography in day-to-day non-academic clinical practice. Materials and methods: Thirteen radiologists from seven centres, who were reporting CT colonography in non-academic daily clinical practice, interpreted a dataset of 15 colonoscopically validated cases in a controlled environment. Ten cases had either a cancer or polyp >10 mm; one case had a medium polyp and four were normal. Correct case categorization and interpretation times were compared using analysis of variance to aggregated results obtained from both experienced observers and observers recently trained using 50 cases, working in an academic environment. The effect of experience was determined using Spearman's rank correlation. Results: Individual accuracy was highly variable, range 53% (95% CI 27-79%) to 93% ...
2007-05-15
Correlation of Multislice CT and Histomorphology in HCC Following TACE: Predictors of Outcome
The purpose of this study was to correlate histopathological with CT findings in patients suffering from hepatocellular carcinoma (HCC) eligible for orthotopic liver transplantation (OLT), with a special focus on the antitumoral effect of transarterial chemoembolization (TACE) therapy. A total of 42 consecutive patients suffering from HCC had been treated prior to OLT by means of TACE. TACE was carried out with a mixture of Lipiodol (10-20 ml) and mitomycin C (max. dosage, 10 mg). TACE was performed at 6- to 8-week intervals. Follow-up investigation included contrast-enhanced multislice CT controls and laboratory control. Liver explants were evaluated macroscopically and microscopically to determine the number and size of the tumor lesions as well as the degree of tumor necrosis. Necrosis was investigated in H and E-stained sections. The degree of necrosis was classified as follows: 0-25%, 26-50%, 51-75%, 75-99%, and ...
2008-07-15
Percutaneous drainage of abdominal abcess
Energy Technology Data Exchange (ETDEWEB)
The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. ...
2002-09-01
International Nuclear Information System (INIS)
Continuous ambulatory peritoneal dialysis (CAPD) is a generally well-tolerated treatment. However, some patients exhibit such complications as to prevent the continuation of treatment. Peritonitis is the major problem, but the continuation of treatment may also be undermined by different complications, such as peritoneal leakage, hernia, catheter malfunctioning, and scrotal-penile edema; a careful investigation of the patient is always needed in such cases. From November 1985 to February 1990, we examined 20 patients, who had presented with different types of complications in the course of dialysis. Peritoneography demonstrated 3 cases of abdominal hernias, 2 cases of patency of the peritoneal-vaginal duct, and 2 cases of catheter obstruction. Peritoneal CT allowed the identification of leakage in 3 patients, while the combined use of the two techniques showed adhesions or pathologic peritoneal recesses in 7 cases. In 3 patients normal patterns were ...
1985-11-01
Energy Technology Data Exchange (ETDEWEB)
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...
1991-11-01
International Nuclear Information System (INIS)
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...
1991-01-01
Point/counterpoint: dose-related issues in cardiac CT imaging
British Library Electronic Table of Contents (United Kingdom)
This manuscript reviews some of the more controversial dose-related issues in cardiac CT imaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CT imaging.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Active contrast material extravasation can be recognized with conventional CT scanners, though it has been considered a rare finding. Helical CT seems to increase the detection rate and especially to boost the radiologist's confidence in this diagnosis. Though active bleeding is defined in severely-injured subjects requiring urgent intervention and may be associated with findings of hypovolaemic shock, it should not be considered itself as a negative prognostic factor. Contrast extravasation is due to ongoing hemorrhage and its detection is critical for urged treatment. Accurate anatomical location permits to choose surgical management or transcatheter embolization and thus decreases time consumption for precis e bleeding site identification. [Italian] Lo stravaso attivo del mdc e' rilevabile anche con appropriate apparecchiature TC tradizionali, sebbene sia stato considerato raro. La ...
1999-03-01
Z-Observables and the Effective Weak Mixing Angle in the MSSM
We make a comparison of the predicted effective weak mixing angle, the Z-on resonance asymmetries and the W-boson mass to the LEP and SLD data at their present status. We find that the predicted MSSM values for the effective weak mixing angle are in agreement with the LEP+SLD average value for a ``heavy'' SUSY breaking scale while we observe an agreement with SLD data in the case of a ``light'' SUSY breaking scale. The resulting values for the W-boson mass and for the electron left-right asymmetries are compatible with CDF,UA2,DO and LEP data respectively. Unexpectedly we find that the supersymmetric QCD contributions to the Z-observables tend to vanish everywhere in the M1/2-M0 plane. Furthermore, values of M1/2 which are greater than 500 GeV are favoured by the MSSM if one considers the current experimental value for the strong coupling.
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
CT is a valuable tool in assessing thoracic gunshot wounds. CT is also the method of choice in emergency, because it permits rapid depiction of bullet damage to the chest and to other body districts. This in turn permits correct assessment of the main thoracic injuries, plus adequate and prompt planning of surgical treatment or support intensive care. It is reported on the role of CT in diagnosing the complex pleuropulmonary, cardiovascular and thoracic wall injuries caused by gunshot wounds, with their specific and acute signs which differ greatly fro those of other types of chest trauma. In the last 4 years, it was observed an amount of 76 cases of gunshot injury, twenty-six of them involved the chest. The patients, 25 men and 1 woman (mean age: 32 years, range: 17-48), were all submitted to emergency CT with iv contrast agent injection and the CT-angiography ...
1999-11-01
Quantification of lung surface area using computed tomography
UK PubMed Central (United Kingdom)
ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available
2010-01-01
UK PubMed Central (United Kingdom)
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
2008-09-01
Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph
UK PubMed Central (United Kingdom)
A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation...Full Text Available
2009-06-21
Dual Energy and Low kVp CT in the Abdomen
UK PubMed Central (United Kingdom)
Low kVp settings provide high conspicuity of contrast materials at CT but may result in high image noise, particularly in larger patients. Material decomposition at dual energy CT can differentiate...Full Text Available
2009-07-01
Invariant asymptotic observers
This paper presents three non-linear asymptotic observers corresponding to three examples of engineering interest: a chemical reactor, a non-holonomic car, and an inertial navigation system. For each example, the design is based on physical symmetries. This motivates the theoretical development of invariant observers, i.e, symmetry-preserving observers. We consider an observer to consist in a copy of the system equation and a correction term, and we give a constructive method (based on the Cartan moving-frame method) to find all the symmetry-preserving correction terms. They rely on an invariant frame (a classical notion) and on an invariant output-error, a less standard notion precisely defined here. For each example, the convergence analysis relies also on symmetries consideration with a key use of invariant state-errors. For the non-holonomic car and the inertial navigation ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An ...
1996-03-01
International Nuclear Information System (INIS)
Computed tomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests that small tumors may be difficult to ...
Thermal properties of UPdSn and UCuSn
International Nuclear Information System (INIS)
We report on the specific heat and the thermopower of UPdSn and UCuSn, both of which order antiferromagnetically at low temperatures. The compounds show similar behaviour in the specific heat, and the large magnetic-entropy changes around T_N are evidence for a large degree of 5f-electron localization. For both compounds, we find that thermopower results are consistent with the findings for the electrical resistance. While for UCuSn very abrupt changes at 25 and 60 K are observed for both quantities, more continuous changes at the magnetic transitions (25 and 40 K) are found for UPdSn. (orig.).
1996-09-24
Phase diagram and effective shape of semi-flexible colloidal rods and biopolymers
We study suspensions of semi-flexible colloidal rods and biopolymers using an Onsager-type second-virial functional for a segmented-chain model. For suspensions of thin and thick fd virus particles we calculate phase diagrams in quantitative agreement with experimental observations, and we find their effective state-point dependent shape to be much shorter and thicker than the actual shape. We also calculate the stretching of worm-like micelles in a host fd virus solution, again finding agreement with experiments. For both systems, our results show that the fd virus stiffness can play a key role in system behavior.
2011-01-01
International Nuclear Information System (INIS)
We have previously reported that FSH stimulates flux of 45Ca2+ into cultured Sertoli cells from immature rats via voltage-sensitive and voltage-independent calcium channels. In the present study, we show that this effect of FSH does not require cholera toxin (CT)- or pertussis toxin (PT)-sensitive guanine nucleotide binding (G) protein or activation of adenylate cyclase (AC). Significant stimulation of 45Ca2+ influx was observed within 1 min, and maximal response (3.2-fold over basal levels) was achieved within 2 min after exposure to FSH. FSH-stimulated elevations in cellular cAMP paralleled increases in 45Ca2+ uptake, suggesting a possible coupling of AC activation to 45Ca2+ influx. (Bu)2cAMP, however, was not able to enhance 45Ca2+ uptake over basal levels at a final concentration of 1000 microM, although a concentration-related increase in androstenedione conversion to estradiol was evident. Exposure of Sertoli cells to ...
1990-01-01
Measuring q sub 0 using supernovae at z approx 0. 3
Energy Technology Data Exchange (ETDEWEB)
The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this system should ...
1992-07-01
Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas
Energy Technology Data Exchange (ETDEWEB)
Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high ...
1999-04-01
CT diagnosis of intrahepatic cholangiocarcinoma
International Nuclear Information System (INIS)
Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All ...
Resonances in gravitational scenario given by deformed branes
In this work we examine a five-dimensional brane-world model with brane structure driven by a real scalar field. From the deformation of a kink-like defect we find a new class of brane solutions containing internal structures which have implications for the way the background space-time is constructed and the way its curvature behaves. Initially, for spin 0 scalar field, we find a zero mode which can be localized on the deformed brane. However, this result can change by the gravitational interaction with the brane internal structure. Analyzing the massive modes of the scalar field, using two different methods, we find resonance structures similar to those found in the study of gravity localization. The main objective here is to observe the contributions of the deformation procedure to the resonances and to the well known field localization methods.
2011-08-01
Intracranial Dural Metastasis of Ewing's Sarcoma: a Case Report
International Nuclear Information System (INIS)
Ewing's sarcoma is a malignant bone tumor that can occur anywhere in the body, but it is most commonly observed in the long bones of the arms and legs, the pelvis and in the chest. The predominant sites of metastasis include the lung (38%), bone (including the spine; 31%), and the bone marrow (11%). Metastasis of Ewing's sarcoma to the central nervous system (CNS) is relatively rare, and most of the previous reports have demonstrated involvement of the bony calvarium or brain parenchyma. We describe here the imaging findings of dural metastasis of Ewing's sarcoma, and these imaging findings have not been previously reported on in the medical literature. In conclusion, dural metastasis of Ewing's sarcoma is very rare and its imaging characteristics are similar to those of a primary tumor, which mimic the findings of a schwannoma or meningioma. Despite its rarity, secondary Ewing's sarcoma may be included ...
2008-02-01
Illness and personality maturation: The search for meaning in severe illness
British Library Electronic Table of Contents (United Kingdom)
Background In scientific literature, when the consequences of illness are discussed, one finds that the deficit perspective is prevailing: Illness as the cause for loss of abilities and a loss of contentment. On the other hand, particularly with creative people, an increase of creativity can be observed, following a confrontation with and having endured a period of illness. When one considers the occurrence of illness retrospectively in a biographical context, one may find often a biographical standstill. Although illness and disease are considered as a collapse, one may observe also psycho-spiritual maturation processes during the confrontation with illness. In several cases illness can thus result in personality maturation and a higher level of psychological health. Aims Despite of the f...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. [Italian] L'integrazione delle immagini diagnostiche aventi diverso contenuto informativo anatomico-funzionale puo' essere utilizzata nella radioterapia per migliorare le procedure diagnostiche e ottimizzare la geometria dell'irraggiamento. I sistemi per l'elaborazione di piani di radioterapia oggi in uso sono direttamente interfacciati con gli apparecchi di Tomografia ...
1999-04-01
Theory of NMR multiple echoes in solid hydrogen
Energy Technology Data Exchange (ETDEWEB)
We have examined the theory of NMR multiple echoes developed for solid {sup 3}He to determine whether multiple echoes could be observed in solid hydrogen. We were particularly interested in the possibility of testing for low frequency quantum tunneling motions in solid hydrogen by the observation of multiple echoes. We find that for easily accessible nuclear spin polarizations, P > 12%, multiple echoes would be observed for HD impurities in solid parahydrogen if motional narrowing is effective in increasing the HD nuclear spin-spin relaxation time T{sub 2} to the order of 1 msec. These values for T{sub 2}, which have been observed for HD impurity concentrations of the order of 1%, are larger than the calculated rigid lattice values and can be attributed to quantum tunneling at frequencies of the order of 1kHz.
1995-11-01
Role of CT in TNM staging of laryngeal and hypopharyngeal tumors
International Nuclear Information System (INIS)
70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.
1986-01-01
Computed tomography - old ideas and new technology
International Nuclear Information System (INIS)
Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)
2011-03-01
CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections
International Nuclear Information System (INIS)
The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections.
1999-03-01
International Nuclear Information System (INIS)
Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One ...
2008-08-01
International Nuclear Information System (INIS)
Full text: The aim of this study was to determine the accuracy of CT colonography (Virtual colonoscopy; VC) for polyp detection in a community-based screening program of asymptomatic subjects at average-risk of colorectal cancer (CRC). Average-risk subjects of two quintiles (50-54 and 65-69 years) were randomly selected from the electoral roll and invited to participate in a VC-based CRC screening program. After bowel preparation, bowel insufflation with CO_2 and intravenous hyoscine butylbromide (unless contra-indicated), supine and prone scans were acquired with a single array GE CTi helical scanner. Scanning parameters were: collimation 3 or 5mm; pitch 1.5:1 or 2.0:1; reconstructions at 1-2mm; 70mAs (5mm collimation) or 120mAs (3mm collimation). Subjects in whom VC demonstrated a polyp were offered colonoscopy (CY) on the same day. Participation rate in the study has been 25%.To date 176 subjects have undergone VC. 41 of 176 (23%) VCs were positive. CY detected ...
2002-06-01
Energy Technology Data Exchange (ETDEWEB)
Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In ...
2000-12-01
CT versus MRI in the study of the articular diseases of the knee
International Nuclear Information System (INIS)
The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.
1999-10-01
Energy Technology Data Exchange (ETDEWEB)
The paper investigates the functional endoscopic sinus surgery with the Messer-linger's technique which treats benign or inflammatory diseases of paranasal sinuses resistant to medical therapy. The goal of this type of surgery is to open the obstructed sinus ostia and restore normal aeration and mucociliary clearance. The computerized tomography permits an accurate assessment of extension and results of functional endoscopic sinus surgery. [Italian] L'articolo discute l'uso della tecnica di Messerklinger nella chirurgia funzionale endoscopica dei seni paranasali per il trattamento delle malattie benigne e delle infiammazioni croniche. Essa disostruisce gli osti sinusali ripristinando la normale areazione e la pulizia mucociliare. La tomografia computerizzata consente di valutare l'estensione e i risultati del trattamento chirurgico funzionale, soprattutto nel caso di insuccesso terapeutico, rilevando malattia nasosinusale ricorrente e-o recidiva.
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
''Hair-on-end'' skull changes resembling thalassemia were rarely described in the 1950s and 1960s in children with cyanotic congenital heart diseases; these changes were described almost entirely in patients with tetralogy of Fallot or D-transposition of the great arteries. As these lesions have become correctable, the osseous changes, never common, seem now only to exist in a small number of patients with uncorrectable complex cyanotic congenital heart disease who survive in a chronic hypoxic state. We present two cases: a case of marked marrow expansion in the skull of a 5-year-old boy with uncorrectable cyanotic heart disease studied by CT, and a second case of an 8-year-old with tetralogy of Fallot and pulmonary atresia studied by plain skull radiographs. The true incidence of these findings is unknown. (orig.)
2005-07-01
PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan
International Nuclear Information System (INIS)
Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)
2007-06-01
Computed tomography in the evaluation of soft tissue tumors
International Nuclear Information System (INIS)
In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).
1990-09-01
Analysis of brain CT on 120 patients of human cysticercosis
International Nuclear Information System (INIS)
A study on brain CT was made in 120 patients of human cysticercosis, which is a rare disease in Japan and clinical symptoms and laboratory data for the diagnosis were also discussed. From the point of therapeutic view, we proposed a new differentiation on brain CT of human cysticercosis, which is divided into two groups according to the alve or dead parasite. Furthermore, we proposed a new type named multiple large and small cysts type on brain CT. The idea of diagnostic standard was made integrating brain CT image, clinical symptoms and labolatory data. (author).
{ital J}/{ital {psi}} Suppression in Pb-Pb Collisions: A Hint of Quark-Gluon Plasma Production?
Energy Technology Data Exchange (ETDEWEB)
The NA50 Collaboration has recently observed a strong suppression of {ital J}/{psi} production in Pb-Pb collisions at 158GeV/nucleon. We show that this recent observation finds a quantitative explanation in a model which relates the suppression mechanism to the local energy density, whose value is higher in Pb-Pb collisions than in any other system studied previously. The sensitivity of the phenomenon to small changes in the energy density could be suggestive of quark-gluon plasma formation. {copyright} {ital 1996 The American Physical Society.}
1996-08-01
International Nuclear Information System (INIS)
We have performed molecular dynamics simulations of radiation damage in fused silica. In this study, we discuss the role of successive cascade overlap on the saturation and self-healing of oxygen vacancy defects in the amorphous fused silica network. Furthermore, we present findings on the topological changes in fused silica due to repeated energetic recoil atoms. These topological network modifications consistent with experimental Raman spectroscopic observation on neutron and ion irradiated fused silica are indicators of permanent densification that has also been observed experimentally.
2003-04-01
Gamma-ray Burst UV/optical afterglow polarimetry as a probe of Quantum Gravity
A possible birefringence effect that arises in quantum gravity leads to a frequency-dependent rotation of the polarization angle of linearly polarized emission from distant sources. Here we use the UV/optical polarization data of the afterglows of GRB 020813 and GRB 021004 to constrain this effect. We find an upper limit on the Gambini & Pulin birefringence parameter $| \\eta | <2\\times 10^{-7}$. This limit is of 3 orders better than the previous limits from observations of AGNs and of the Crab pulsar. Much stronger limits may be obtained by the future observation of polarization of the prompt $\\gamma$-rays.
2007-01-01
Fractal analysis of deformation-induced dislocation patterns
Energy Technology Data Exchange (ETDEWEB)
The paper reports extensive analyses of the fractal geometry of cellular dislocation structures observed in Cu deformed in multiple-slip orientation. Several methods presented for the determination of fractal dimensions are shown to give consistent results. Criteria are formulated which allow the distinguishing of fractal from non-fractal patterns, and implications of fractal dislocation patterning for quantitative metallography are discussed in detail. For an interpretation of the findings a theoretical model is outlined according to which dislocation cell formation is associated to a noise-induced structural transition far from equilibrium. This allows relating the observed fractal dimensions to the stochastic properties of deformation by collective dislocation glide.
1999-06-22
Energy Technology Data Exchange (ETDEWEB)
Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant GTV-t shrinkage ...
2010-10-15
Energy Technology Data Exchange (ETDEWEB)
The study reports ultrasonography and computerise tomography findings in 16 patients with amoebic abscesses, 12 of whom lived in a temperate peripheral area north-east of Naples (Italy). All patients have a clinical-diagnostic condition called sub-urban amoebiasis. The personal experience with the US guided therapeutic drainage of amoebic abscess with repeated cavity washing, which is important for positive parasitology. Combined US and CT assessment facilitated the diagnosis of amoebiasis and its differentiation from pyogenic abscess and hepatoma. [Italian] La colonizzazione epatica rappresenta la localizzazione piu' comune dell'amebiasi extraintestinale e gli ascessi epatici ne costituiscono la manifestazione piu' frequente sviluppandosi nel 3-9 % dei pazienti affetti da infezione parassitaria. Diversi studi confermano che la terapia medica dell'amebiasi risulta piu' efficace quando viene associato ...
2000-03-01
2001 Report on the Next Linear Collider
Energy Technology Data Exchange (ETDEWEB)
Recent studies in elementary particle physics have made the need for an e{sup +}e{sup -} linear collider able to reach energies of 500 GeV and above with high luminosity more compelling than ever [1]. Observations and measurements completed in the last five years at the SLC (SLAC), LEP (CERN), and the Tevatron (FNAL) can be explained only by the existence of at least one particle or interaction that has not yet been directly observed in experiment. The Higgs boson of the Standard Model could be that particle. The data point strongly to a mass for the Higgs boson that is just beyond the reach of existing colliders. This brings great urgency and excitement to the potential for discovery at the upgraded Tevatron early in this decade, and almost assures that later experiments at the LHC will find new physics. But the next generation of experiments to be mounted by the world-wide particle physics community must not only ...
2001-08-28
Wind instability of a foam layer sandwiched between the atmosphere and the ocean
Kelvin-Helmholtz instability of short gravity waves is examined in order to explain the recent findings of the decrease in momentum transfer from hurricane winds to sea waves. A three-fluid configuration of a foam layer between the atmosphere and the ocean is suggested to provide signifficant stabilization of the system and shifting the marginal critical wavelength to the shortwave part of the spectrum. It is conjectured that such stabilization leads to the observed drag reduction. The high contrasts in three fluid densities provide a universal mechanism for stabilizing surface perturbations.
2007-01-01
Warm-Intermediate inflationary universe model in braneworld cosmologies
Warm-intermediate inflationary universe models in the context of braneworld cosmologies, are studied. This study is done in the weak and strong dissipative regimes. We find that, the scalar potentials and dissipation coefficients in terms of the scalar field, evolves as type-power-law and powers of logarithms, respectively. General conditions required for these models to be realizable are derived and discussed. We also study the scalar and tensor perturbations for each regime. We use recent astronomical observations to constraint the parameters appearing in the braneworld models.
2011-01-01
Strong WW scattering at photon linear colliders
Energy Technology Data Exchange (ETDEWEB)
We investigate the possibility of observing strong interactions of longitudinally polarized weak vector bosons in the process {gamma}{gamma}{yields}ZZ at a photon linear collider. We make use of polarization of the photon beams and cuts on the decay products of the Z bosons to enhance the signal relative to the background of transversely polarized ZZ pairs. We find that the background overwhelms the signal unless there are strong resonant effects, as for instance from a technicolor analogue of the hadronic f{sub 2}(1270) meson. ((orig.)).
1995-02-01
Strong WW scattering at photon linear colliders
Energy Technology Data Exchange (ETDEWEB)
We investigate the possibility of observing strong interactions of longitudinally polarized weak vector bosons in the process {gamma}{gamma} {yields} ZZ at a photon linear collider. We make use of polarization of the photon beams and cuts on the decay products of the Z bosons to enhance the signal relative to the background of transversely polarized ZZ pairs. We find that the background overwhelms the signal unless there are strong resonant effects, as for instance from a technicolor analogue of the hadronic f{sub 2}(1270) meson.
1994-06-01
New Polynomial Classes for Logic-Based Abduction
We address the problem of propositional logic-based abduction, i.e., the problem of searching for a best explanation for a given propositional observation according to a given propositional knowledge base. We give a general algorithm, based on the notion of projection; then we study restrictions over the representations of the knowledge base and of the query, and find new polynomial classes of abduction problems.
2011-01-01
Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses
Energy Technology Data Exchange (ETDEWEB)
Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.
2007-11-15
Ghost-free braneworld bigravity
Energy Technology Data Exchange (ETDEWEB)
We consider a generalization of the DGP model, by adding a second brane with localized curvature, and allowing for a bulk cosmological constant and brane tensions. We study radion and graviton fluctuations in detail, enabling us to check for ghosts and tachyons. By tuning our parameters accordingly, we find bigravity models that are free from ghosts and tachyons. These models will lead to large distance modifications of gravity that could be observable in the near future.
2004-06-21
Effect of calcination and physico-chemical properties of red mud
Energy Technology Data Exchange (ETDEWEB)
Physico-chemical studies were carried out on a sample of red mud collected from NALCO, Orissa, after calcination up to 1,200 C at an interval of 100 C. The observed change in properties like surface area, particle size, bulk density and mineral phases etc., can be profitably used while finding an appropriate application of this polluting waste from alumina plants.
1996-10-01
ELECTRON MICROSCOPE PREPARATIONS OF RADIOACTIVELY LABELED AEROSOLS
A method is described to smear extremely thin layers of nuclear emulsion on labeled electron microscope preparations and to measure the thicknesses of these layers, Without further separation, preparation and emulsion can be observed after exposure and development in an electron microscope. The source of the tracks formed in the emulsion can be exactly identified and the size and structure determined. This method finds applications in dust research and also in the analysis of medical and biological sections. Further information can be obtained about properties of different emulsions. (auth)
1963-04-01
Energy Technology Data Exchange (ETDEWEB)
Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with aspecific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases ...
2000-06-01
CT-Expo - a novel program for dose evaluation in CT
International Nuclear Information System (INIS)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free ...
2002-12-01
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules ...
2006-04-01
Energy Technology Data Exchange (ETDEWEB)
Lipiodol CT is a important modality for the diagnosis of hepatocellular carcinoma and compared is usually performed at 2-3 week after Lipiodol injection. Therefore, we assessed and the diagnostic value and merits of immediate CT after chemoembolization from there of 2-3 week delayed Lipiodol CT. Thirty three cases of chemoembolization which were performed both immediate CT after chemoembolization and 2-3 week delayed Lipiodol CT were reviewed retrospectively. They were divided into four grades according to pattern of lipiodol uptake by three radiologists. The diagnostic value of immediate Lipiodol CT was compared to delayed Lipiodol CT. Grade 0 was two cases(3.0%) and Grade 1 was seven cases(21.2%). In the cases of Grade 2(23/33, 69.7%), tumor uptake could be dishing wished from parenchymal uptake of Lipiodol by its density and pattern, ...
1995-08-15
Interferometer Observations of Subparsec-scale Infrared Emission in the Nucleus of NGC 4151
We report novel, high-angular resolution interferometric measurements that imply the near-infrared nuclear emission in NGC 4151 is unexpectedly compact. We have observed the nucleus of NGC 4151 at 2.2 microns using the two 10-meter Keck telescopes as an interferometer and find a marginally resolved source ~0.1 pc in diameter. Our measurements rule out models in which a majority of the K band nuclear emission is produced on scales larger than this size. The interpretation of our measurement most consistent with other observations is that the emission mainly originates directly in the central accretion disk. This implies that AGN unification models invoking hot, optically thick dust may not be applicable to NGC 4151.
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free ...
2002-12-01
Limits on the Diffuse Radio and Hard X-ray Emission of Abell 2199
The Westerbork Northern Sky Survey (WENSS) and the NRAO/VLA Sky Survey (NVSS) were used to determine an upper limit to the diffuse radio flux from the nearby cluster Abell 2199. For the entire cluster, this limit is <3.25 Jy at 327 MHz from WENSS; for the inner 15' radius, the limit is <168 mJy at 1.4 GHz. These limits are used to constrain the cluster magnetic field by requiring that the radio flux be consistent with the hard X-ray (HXR) flux observed by BeppoSAX, assuming that the observed HXR excess is due to inverse Compton (IC) scattering of cosmic microwave background photons by relativistic electrons in the intracluster gas. We find that the magnetic field must be very weak (<0.073 uG) in order to avoid producing an observable radio halo. We also consider the possibility that the HXR excess is due to nonthermal bremsstrahlung (NTB) by a population of suprathermal electrons which are ...
1999-01-01
Latest Observational Constraints on Cardassian Models
Constraints on the original Cardassian model and the modified polytropic Cardassian model are examined from the latest derived 397 Type Ia supernova (SNe Ia) data, the size of baryonic acoustic oscillation peak from the Sloan Digital Sky Survey (SDSS), the position of first acoustic peak of the Cosmic Microwave Background radiation (CMB) from the five years Wilkinson Microwave Anisotropy Probe (WMAP), the x-ray gas mass fractions in clusters of galaxies, and the observational H(z) data. In the original Cardassian model with these combined data set, we find $\\Omega_{m0}=0.271^{+0.014}_{-0.014}, n=0.035^{+0.049}_{-0.049}$ at $1 \\sigma$ confidence level. And in the modified polytropic Cardassian model, we find that $\\Omega_{m0}=0.271^{+0.014}_{-0.015}$, $n=-0.091^{+0.331}_{-1.908}$ and $\\beta=0.824^{+0.750}_{-0.622}$ within $1\\sigma$ confidence level. According to these observations, the acceleration ...
2009-01-01
Integral Field Unit Observations of NGC 4302: Kinematics of the Diffuse Ionized Gas Halo
We present moderate resolution spectroscopy of extraplanar diffuse ionized gas (EDIG) emission in the edge-on spiral galaxy NGC 4302. The spectra were obtained with the SparsePak integral field unit (IFU) at the WIYN Observatory. The spectra are used to construct position-velocity (PV) diagrams at several ranges of heights above the midplane. Azimuthal velocities are directly extracted from the PV diagrams using the envelope tracing method, and indicate an extremely steep dropoff in rotational velocity with increasing height, with magnitude ~30 km/s/kpc. We find evidence for a radial variation in the velocity gradient on the receding side. We have also performed artificial observations of galaxy models in an attempt to match the PV diagrams. The results of a statistical analysis also favor a gradient of ~30 km/s/kpc. We compare these results with an entirely ballistic model of disk-halo flow, and find a strong dichotomy ...
2007-01-01
Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors
International Nuclear Information System (INIS)
339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved ...
Energy Technology Data Exchange (ETDEWEB)
The main purpose of this work is to evaluate the role of CT in identifying other morphological signs of met static lymph node involvement from non small cell bronchogenic carcinoma. This is done to improve N staging, a critical step in this disease. In fact, since diameter is the only criterion used to distinguish normal form abnormal lymph nodes, mediastinal CT only has 80% diagnostic accuracy. 137 patients with known or suspected lung cancer were examined with Helical CT during early and late arterial phases (2 min. delay, 3 mm thickness, 5 mm inter slice gap) to depict node characteristics. Mediastinal lymph nodes, located according to the American Thoracic Society mapping, were considered normal when they were not visible or, if visible, less than 1 cm in diameter and of homogeneous density; lymph nodes over 1 cm in diameter and homogenous density were considered reactive. A lymph node was considered metastatic when, ...
2000-05-01
The antiviral drug combination consisting of arbidol and acetaminophen was investigated for its 4-week repeated oral administration in Sprague-Dawley rats. Groups of rats (10/sex in low-dose group, 15/sex in other three groups) were given at doses of 0, 200, 400, and 800 mg/kg/day. Clinical signs, mortality, body weight, food consumption, hematology, clinical biochemistry, macroscopic findings, organ weights, and histopathology were examined. The administration resulted in increased incidence of piloerection in most of the high-dose females and in some of the high-dose males and mid-dose females. Histopathological examinations revealed minor treatment-related change in the stomach of the high-dose animals. A decrease in body-weight gains and an increase in liver weight were observed in the mid- and high-dose groups. These treatment-related effects were reversible at the 2-week recovery period. A number of other clinical and pathological ...
2010-07-01
British Library Electronic Table of Contents (United Kingdom)
We revisit a recently proposed agent-based model of active biological motion and compare its predictions with own experimental findings for the speed distribution of bacterial cells, Salmonella typhimurium. Agents move according to a stochastic dynamics and use energy stored in an internal depot for metabolism and active motion. We discuss different assumptions of how the conversion from internal to kinetic energy d(v) may depend on the actual speed, to conclude that d 2 v ? with either ? = 2 or 1 ? < 2 are promising hypotheses. To test these, we compare the model?s prediction with the speed distribution of bacteria which were obtained in media of different nutrient concentration and at different times. We find that both hypotheses are in line with the experimental observations, with ? bet...
2011-01-01
Stop-and-go kinetics in amyloid fibrillation
Many human diseases are associated with protein aggregation and fibrillation. We present experiments on in vitro glucagon fibrillation using total internal reflection fluorescence microscopy, providing real-time measurements of single-fibril growth. We find that amyloid fibrils grow in an intermittent fashion, with periods of growth followed by long pauses. The observed exponential distributions of stop and growth times support a Markovian model, in which fibrils shift between the two states with specific rates. Remarkably, the probability of being in the growing (stopping) state is very close to 1/4 (3/4) in all experiments, even if the rates vary considerably. This finding suggests the presence of 4 independent conformations of the fibril tip; we discuss this possibility in terms of the existing structural knowledge.
2009-01-01
Revenue management: the impact on business-to-business relationships
British Library Electronic Table of Contents (United Kingdom)
Purpose - This paper aims to explore the links between revenue management and business-to-business (B2B) relationships and explains how revenue management can both support and damage B2B relationships. Design/methodology/approach - A single case study method was employed to conduct qualitative research into a company and its key accounts. In-depth data were collected from three divergent sources (company revenue managers, company account managers and nine of the company's key accounts) through semi-structured interviews, observations and document studies. Findings - The research findings reveal that from the company's perspective, managers acknowledge that revenue management has positively influenced the process of identifying and analysing key account activities and conducting contractual...
2009-01-01
Response variability in balanced cortical networks
DEFF Research Database (Denmark)
We study the spike statistics of neurons in a network with dynamically balanced excitation and inhibition. Our model, intended to represent a generic cortical column, comprises randomly connected excitatory and inhibitory leaky integrate-and-fire neurons, driven by excitatory input from an external population. The high connectivity permits a mean field description in which synaptic currents can be treated as gaussian noise, the mean and autocorrelation function of which are calculated self-consistently from the firing statistics of single model neurons. Within this description, a wide range of Fano factors is possible. We find that the irregularity of spike trains is controlled mainly by the strength of the synapses relative to the difference between the firing threshold and the postfiring reset level of the membrane potential. For moderately strong synapses, we find spike statistics very similar to those observed in ...
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
In the past few decades, research on gender and language learning styles (LLSs) across various EFL/ESL contexts has received remarkable attention. From these studies, a multitude of contradictory and heterogeneous findings has been observed which justify additional research in SLA contexts in general and EFL contexts like Iran in particular. Hence, the present study attempted to explore the relationship between Iranian EFL students' perceptual learning styles and gender. For this aim, a 32-item questionnaire was administered to 105 EFL students at Ilam University, Iran. Results of quantitative research and statistical analysis of findings indicated that both male and female students inclined to be bimodal learners who were visual/non-verbal (V/NV) rather than being trimodal or single learn...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
PurposeTo characterize the morphology of outer retinal holes caused by solar maculopathy, using spectral-domain optical coherence tomography (SD-OCT). DesignThis study is an observational case series. MethodsThe SD-OCT findings of 3 patients (6 eyes) with chronic solar maculopathy are presented. ResultsSD-OCT demonstrates a characteristic appearance of partial-thickness hole(s) in the outer retina at the fovea. In 3 of 6 eyes, there is 1 hole directly beneath the umbo. In the remaining 3 eyes, there are multifocal holes spread across the fovea. Holes in more restricted layers, as had been previously reported with time-domain OCT, were not seen. In addition, advanced visualization of SD-OCT data demonstrates a hyperreflective ring around the outer retinal hole. ConclusionsSD-OCT can be used...
2011-01-01
Effects of cryopreservation on germinability of olive (Olea europaea L.) pollen
British Library Electronic Table of Contents (United Kingdom)
Long term storage of viable pollen is important for bank germplasm constitution to preserve resources that can be used in breeding programs, biotechnologies and genetic engineering. Pollen from 12 olive (Olea europaea L.) cultivars was stored for 1?year in liquid nitrogen at ?196?C. The morphology of pollen grains and germination rates on fresh and long term stored pollen were observed. Results on in vitro pollen germinability, both before and after cryopreservation, showed highly significant responses among the 12 cultivars. The relationship between germinability and pollen grain size did not reveal any significant relationships in both treatments. Our findings will contribute to the improvement of olive pollen preservation and lead to find a more efficient method for its long term storag...
2011-01-01
These three separate pamphlets provide background information, brief discussions of research findings, and guidelines and recommendations concerning selected aspects of diet. The first pamphlet discusses food additives and hyperactivity, focusing on both the Feingold theory and controlled experiments which do not support Feingold's clinical observations and case reports. (The Feingold theory claims that artificial food flavors and colors and antioxidant preservatives cause hyperactivity in genetically predisposed individuals.) The second pamphlet discusses fast food and the American diet as they are related to sound nutritional principles. The third pamphlet, focusing on alcohol use during pregnancy, lists principles and associated features of the fetal alcohol syndrome and presents research findings and recommendations concerning alcohol use during pregnancy. (RH)
1980-12-01
Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience
International Nuclear Information System (INIS)
The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was ...
2010-08-01
International Nuclear Information System (INIS)
The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in cerebral cortex (CX) of ID rats were ...
2004-02-27
Energy Technology Data Exchange (ETDEWEB)
Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 ...
2001-11-01
TLD assessment of mouse dosimetry during microCT imaging
UK PubMed Central (United Kingdom)
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
2008-09-01
SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY
UK PubMed Central (United Kingdom)
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available
2009-08-07
Role of CT in the assessment of the volume to be irradiated in bone metastases
International Nuclear Information System (INIS)
In the Department of Radiology of Catholic University S. Cuore in Rome, a review was made of 342 CT examinations with a view towards optimizing the therapeutic planning in patients affected by bone metastases. All patients were submitted to radiological positioning and then to CT evaluation in order to assess the volume to be treated. In 224 cases it was not necessary to perform wide CT examination (3-5 standard tomograms being enough, 2 of which at the superior and inferior margins of the planned field). In the second group of 118 patients it was necessary to perform CT (serial axial scans) - increasing by 1-1.5 cm - up to the superior and inferior margins of the lesion. The existence of 2 types of lesions was confirmed: those involving mainly bony structures and those infiltrating the soft tissues. CT evaluation allowed the definition of the target volume to the real extension of ...
1988-01-01
Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples
UK PubMed Central (United Kingdom)
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy
UK PubMed Central (United Kingdom)
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
2009-01-01
Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging
UK PubMed Central (United Kingdom)
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
2010-09-01
Energy Technology Data Exchange (ETDEWEB)
Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the ...
1984-09-01
Ganglioneuromas in childhood: MRI and CT characteristics
International Nuclear Information System (INIS)
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in ...
2000-05-01
UK PubMed Central (United Kingdom)
Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available
2008-01-01
UK PubMed Central (United Kingdom)
BackgroundThe purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).MethodsTwenty-three...Full Text Available
Gastric stromal tumors. CT findings; Tumori stromali gastrici. Aspetti con Tomografia Computerizzata
Energy Technology Data Exchange (ETDEWEB)
Gastric stromal tumors are an ill-defined group of lesions arising from muscle wall cells and characterized by extremely variable biological patterns. Thanks to modern immunohistochemical and ultrastructural techniques, four main classes of these lesions have been identified, namely: (1) tumors with differentiation toward smooth muscle cells; (2) tumors with differentiation toward neural elements; (3) tumors with differentiation toward neural elements; (3) tumors with dual differentiation toward either cell type. It was investigated the yield of CT in diagnosing and characterizing gastric stromal tumors. It was retrospectively reviewed the CT findings of 38 patients (15 men and 23 women; mean age 51 years) with pathologically proven gastric stromal tumors, namely 31 of myoid origin, 4 of neural origin, 2 with both muscle and neural differentiation, 1 lacking differentiation with either cell type. The myoid tumors involved ...
2000-02-01
Energy Technology Data Exchange (ETDEWEB)
Rectus sheath hematomas are a frequent but sometimes misdiagnosed disease in patients under anticoagulative drugs, hemodialysis, or simply in the elderly. The most frequent localization is in the lower part of the abdomen: the explanation lies in the anatomy of the abdominal wall, especially in the arcuate line of the rectus sheath. Aim of this work is to explain the reason of the almost constant location correlating the anatomy with the CT features. The rectus abdominis muscle lies between the aponeuroses of the transverse and oblique muscles which form the so called rectus sheath. This arrangement is found from the costal arch to a level approximately between the umbilicus and the pubic symphisis, where the rear layer of the rectus sheath ends with a curved edge, called the arcuate or semicircular line of Douglas. Beneath this line the aponeuroses of the three muscles pass in front of the rectus which is separated from the peritoneum only by the fascia ...
2000-06-01
PET/CT cardiology: an area whose boundaries are still out of sight
International Nuclear Information System (INIS)
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
2006-05-01
Energy Technology Data Exchange (ETDEWEB)
To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)
2002-01-01
Computed Tomography of the cranio-cervical junction in rhematoid arthritis
International Nuclear Information System (INIS)
Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.
1987-01-01
CT-pathologic correlation of focal area of ground-glass attenuation (GGA) in the peripheral lung
Energy Technology Data Exchange (ETDEWEB)
We compared the characteristics on thin-section CT images with the histological structure of thirty-four surgically resected peripheral lung lesions 30 mm or less in diameter with a greater than 50% area of GGA on thin-section CT. Pathologically, focal area of GGA corresponded to alveolar replacement growth of tumor or interstitial fibrotic thickening of inflammation. It is considered that determination of the GGA in small peripheral lung lesions on thin-section CT is useful for the diagnosis of early adenocarcinomas. (author)
2001-07-01
Lung studies with spiral CT. pitch 1 versus pitch 2
International Nuclear Information System (INIS)
In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.
1999-03-01
Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography
International Nuclear Information System (INIS)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
1999-05-01
Computer tomography of orbita in children
Energy Technology Data Exchange (ETDEWEB)
The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.
1983-07-01
Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method
Energy Technology Data Exchange (ETDEWEB)
Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.
1982-01-01
Computed tomography of the chest: A teaching file
Energy Technology Data Exchange (ETDEWEB)
As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.
1987-01-01
CT manifestations of ileal dysgenesis
Energy Technology Data Exchange (ETDEWEB)
Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)
2007-02-15
Energy Technology Data Exchange (ETDEWEB)
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of ...
1996-03-01
The role of Computerized Tomography in osteoid-osteoma diagnosis
International Nuclear Information System (INIS)
Alcaptonuria is a rare autosomal recessive metabolic disease, due to the lack of homogentisic acid oxidase. The following accumulation of homogentisic acid brings about a black discoloration of both the urine alcaptonuria) and connective tissue (ochronosis). The ochronotic alterations into joint cartilages cause degenerative arthropathy and osteopenia. The radiological features of three unrelated cases of alcaptonuria are reported. Radiographic abnormalities of ochconotic arthropathy are found in both the spine and the extraspinal joints. In the spine, the progressive calcification and ''vacuum'' phenomenon of disc spaces are the most characteristic findings. Disc space narrowing is associated with calcification and marginal sclerosis of vertebral bodies and is accentuated by osteopenia. Osteophytes are usually absent or of small size; neverthless progressive formation of marginal intervertebral bridges and obliteration of disc spaces at multiple levels ...
1988-01-01
Phenomenology of a light gluon resonance in top-physics at Tevatron and LHC
We present a phenomenological analysis of the recent Tevatron results on the $t \\bar t$ forward-backward asymmetry and invariant-mass spectrum assuming a new contribution from an s-channel gluon resonance with a mass in the range from 700 to 2500 GeV. In contrast to most of the previous works, this analysis shows that for masses below ~1 TeV resonant New Physics could accommodate the experimental data. In general, we find that axial-like couplings are preferred for light and top quark couplings, and that only top quark couples strongly to New Physics. We find that composite model scenarios arise naturally from only phenomenological analyses of the experimental results. We show that our results are compatible with recent LHC limits in dijet and $t \\bar t$ production, and find some tension for large resonance mass ~2.5 TeV. We indicate as best observables for discriminating a relatively light new gluon ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and ...
2005-03-01
Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the high dose rates. It was found that the ...
2005-11-23
MONTE CARLO SIMULATIONS OF GLOBULAR CLUSTER EVOLUTION. V. BINARY STELLAR EVOLUTION
International Nuclear Information System (INIS)
We study the dynamical evolution of globular clusters containing primordial binaries, including full single and binary stellar evolution using our Monte Carlo cluster evolution code updated with an adaptation of the single and binary stellar evolution codes SSE and BSE from Hurley et al. We describe the modifications that we have made to the code. We present several test calculations and comparisons with existing studies to illustrate the validity of the code. We show that our code finds very good agreement with direct N-body simulations including primordial binaries and stellar evolution. We find significant differences in the evolution of the global properties of the simulated clusters using stellar evolution compared with simulations without any stellar evolution. In particular, we find that the mass loss from the stellar evolution acts as a significant energy production channel simply by reducing the total gravitational ...
2010-08-10
The double crystal technique - its application to resconstructed InSb (001) and Xe layers
International Nuclear Information System (INIS)
The early work of Stern has been reviewed briefly along with some of our experiments carried out later with similar geometrical arrangements in order to highlight his successes at the time and the future developments of his findings and predictions. The double crystal technique, developed by Stern has been used for energy analysis of He beams and results are shown for scattering from a rough reconstructed (001) InSb surface and Xe adsorbed layers. Surface phonons were not observed in the case of InSb probably as a result of the rough surface. (orig.).
1988-01-01
Sustaining integrated technology in undergraduate mathematics
British Library Electronic Table of Contents (United Kingdom)
The effective integration of technology into the teaching and learning of mathematics remains one of the critical challenges facing contemporary tertiary mathematics. This article reports on some significant findings of a wider study investigating the use of technology in undergraduate mathematics. It first discusses a taxonomy developed to describe and compare technology use within individual courses and departments that identifies a complex range of factors, summarized under six defining characteristics of an integrated technology mathematics curriculum (ITMC). An instrument for a simple comparison of technology use employing the elements of this taxonomy is provided. It then presents evidence gathered from an observational study of technology implementation at The University of Auckland...
2011-01-01
High-energy Cosmic-Ray Positrons from Hidden-Gauge-Boson Dark Matter
We provide a scenario in which a hidden U(1) gauge boson constitutes dark matter of the Universe and decays into the standard-model particles through a kinetic mixing with an $U(1)_{B-L}$ gauge boson. Interestingly, our model can naturally account for the steep rise in the positron fraction recently reported by PAMELA. Moreover, we find that due to the charge assignment of $U(1)_{B-L}$, only a small amount of antiprotons are produced in the decay, which is also consistent with the PAMELA and other observational data.
2008-01-01
Hall mobility minimum of temperature dependence in polycrystalline silicon
Molten zone recrystallized as well as sheet grown polycrystalline silicon has shown a minimum in the temperature dependence of the Hall mobility. In order to explain this experimental finding a new model is proposed, which is based on negatively charged grain boundaries for the p-type silicon material under study. This results in a potential well at the grain boundaries instead of the more generally observed potential barrier. A key feature in the model is that the space charge density at the grain boundary depends on the Fermi level position and therefore on temperature. In addition, the change in the measured Hall mobility before and after hydrogen passivation of the grain boundaries is discussed.
1998-01-01
Gravitational Waves from Collapsing Domain Walls
We study the production of gravitational waves from cosmic domain walls created during phase transition in the early universe. We investigate the process of formation and evolution of domain walls by running three dimensional lattice simulations. If we introduce an approximate discrete symmetry, walls become metastable and finally disappear. We calculate the spectrum of gravitational waves produced by collapsing metastable domain walls. Extrapolating the numerical results, we find the signal of gravitational waves produced by domain walls whose energy scale is around 10^10-10^12GeV will be observable in the next generation gravitational wave interferometers.
2010-01-01
Excitation of 1/sup +/ states in /sup 88/Sr by proton inelastic scattering
Energy Technology Data Exchange (ETDEWEB)
In a (p,p') study of /sup 88/Sr at Esub(p) = 201 MeV both a large resonance centered at 9.4 MeV excitation energy and the known 1/sup +/ state at 3.486 MeV are excited. Several discrete states are observed in the resonance. The cross section of the whole resonance is 27% of a simple particle-hole prediction. The strength of the low-lying 1/sup +/ state is only about 15% of that calculated from a wave function including core-polarization contributions, whereas (e,e') scattering finds about 50%.
1985-06-10
Excitation of 1"+ states in "8"8Sr by proton inelastic scattering
International Nuclear Information System (INIS)
In a (p,p') study of "8"8Sr at Esub(p) = 201 MeV both a large resonance centered at 9.4 MeV excitation energy and the known 1"+ state at 3.486 MeV are excited. Several discrete states are observed in the resonance. The cross section of the whole resonance is 27% of a simple particle-hole prediction. The strength of the low-lying 1"+ state is only about 15% of that calculated from a wave function including core-polarization contributions, whereas (e,e') scattering finds about 50%. (orig.).
Employing exergy-optimized pin fins in the design of an absorber in a solar air heater
Energy Technology Data Exchange (ETDEWEB)
Fins serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Pin fins are relatively good heat transfer augmentation features with superior aerodynamic performance, and as a result find application in some solar air heaters. The exergy optimization method is employed in sizing the pin fin. Results indicate that high efficiency of the optimized fin improves the heat absorption and dissipation potential of a solar air heater. With optimum fin efficiency and superior absorptive coating quality, useful energy losses can be minimized. Some important observations pertinent in design are made. (author)
2010-02-15
Cosmological surveys with the Australian Square Kilometre Array Pathfinder
This is a design study into the capabilities of the Australian Square Kilometre Array Pathfinder (ASKAP) in performing a full-sky low redshift neutral hydrogen survey, termed WALLABY, and the potential cosmological constraints one can attain from measurement of the matter power spectrum. We find that the full sky survey will likely attain 600,000 redshifts which, when combined with expected Planck CMB data, will constrain the Dark Energy equation of state to 20%, for the first time making cosmological constraints from radio observations competitive with the best existing optical surveys.
2011-01-01
Convoy electron production in polycrystalline and monocrystalline targets
Energy Technology Data Exchange (ETDEWEB)
The velocity distribution of electrons ejected close to the forward direction by 0.8-2 MeV/A ions traversing various solid targets, including a Au monocrystal, is measured in coincidence with emerging charge-selected ions. The velocity spectrum is observed to be independent of outgoing projectile velocity and charge state for polycrystalline targets. Measurements on the Au crystal under channeling conditions show dependences on final charge state, and are tentatively explained by assuming that the main contribution to the production yield comes from the non-channeled fraction of the ions. A simple model for the creation of the forward-ejected electrons is proposed, which accounts for most of the experimental findings.
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Since 1983, about 600 research projects received a total of DM 250 million public funds for the following tasks: - Development of scientific fundamentals for monitoring and observation of forest decline and its ecological and economic consequences. - Investigation of the cause-effect relationship of forest damage, with particular regard to the involvement of the various compartments of the forest ecosystem and to the contribution of different pollutants. - Development of the scientific fundamentals required for forestry measures to accompany the air pollution abatement measures. The investigations comprised both laboratory and field tests. The findings and conclusion are summarized. (orig./MG).
1988-12-01
All Optical Switch of Vacuum Rabi Oscillations: The Ultrafast Quantum Eraser
We study the all-optical time-control of the strong coupling between a single cascade three-level quantum emitter and a microcavity. We find that only specific arrival-times of the control pulses succeed in switching-off the Rabi oscillations. Depending on the arrival times of control pulses, a variety of exotic non-adiabatic cavity quantum electrodynamics effects can be observed. We show that only control pulses with specific arrival times are able to suddenly switch-off and -on first-order coherence of cavity photons, without affecting their strong coupling population dynamics. Such behavior may be understood as a manifestation of quantum complementarity.
2010-01-01
Advances in Old-Fashioned Heterotic String Model Building
I review findings of various research groups regarding perturbative heterotic string model building in the last 12 months. Attention is given to recent studies of extra U(1)'s and local discrete symmetries (LDS's) in generic string models. Issues covered include the role of U(1)'s and LDS's in limiting proton decay, developments in classification of models containing anomalous U(1), and possible complications resulting from kinetic mixing between observable and hidden sector U(1)'s. Additionally, recent string-derived and string-inspired models are briefly reviewed. Talk Presented at SUSY '97.
1998-01-01
A light charged Higgs boson in two-Higgs doublet model for CDF $Wjj$ anomaly
Motivated by recent anomalous CDF data on $Wjj$ events, we study a possible explanation within the framework of the two-Higgs doublet model. We find that a charged Higgs boson of mass $\\sim$ 140 GeV with appropriate couplings can account for the observed excess. In addition, we consider the flavor-changing neutral current effects induced at loop level by the charged Higgs boson on the $B$ meson system to further constrain the model. Our study shows that the like-sign charge asymmetry $A_{s\\ell}^b$ can be of ${\\cal O}(10^{-3})$ in this scenario.
2011-01-01
Tracheal compression by mediastinal masses in children: CT evaluation
Energy Technology Data Exchange (ETDEWEB)
Chest computed tomography (CT) was valuable in detecting extrinsic tracheal compression by mediastinal masses in two pediatric patients. This prompted an independent evaluation by CT of 14 children with masses involving the middle mediastinum and possible intrathoracic tracheal narrowing. Computer programs permit precise calculation of tracheal cross-sectional areas. Any apparent decrease in tracheal area may be compared with CT-derived data in normal children. Chest CT not only demonstrates the presence of extrinsic airway compression in pediatric patients with mediastinal masses, but also is capable of precisely measuring the extent of this narrowing. This method identifies children at potential risk for respiratory compromise and may aid in subsequent therapy.
1983-10-01
Role of Computed Tomography in postoperative diskitis
International Nuclear Information System (INIS)
Six patients with diskitis following lumbar disk surgery were investigated by Computed Tomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic ...
1988-01-01
International Nuclear Information System (INIS)
Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).
Radiation risk in computerized tomography (CT)
Energy Technology Data Exchange (ETDEWEB)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...
1984-01-01
Radiation risk in computerized tomography (CT)
International Nuclear Information System (INIS)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...
1984-01-01
Radiation risk in computerized tomography (CT)
International Nuclear Information System (INIS)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...
Lacrimal gland masses on CT and MRI: a report of four cases
International Nuclear Information System (INIS)
In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.).
International Nuclear Information System (INIS)
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such ...
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
We evaluated the relation between the lipiodol accumulative pattern on CT 1 month after 1st Lp-TAE and the effect of Lp-TAE and recurrence of hepatocellular carcinoma (HCC) in 70 cases undergoing Lp-TAE twice. The lipiodol accumulative pattern on CT can be classified into four types (I: homogeneous, II: defect, III: inhomogeneous, IV: no or slight). In the type I, recurrence of the main tumor was 26.7%, daughter was 73.7%, suggesting a good effect of Lp-TAE. In the types II, III and IV, recurrence of the main tumor was seen in 66.7%, 83.3% and 83.3%, respectively, suggesting that the effect of Lp-TAE was worse according to the lipiodol accumulative pattern on CT. The lipiodol accumulative pattern on CT is useful for the detection of recurrence and assessment of the effect of Lp-TAE. (author).
1993-08-01
Computed tomography of middle ear cholesteatomas without tympanic membrane perforation
International Nuclear Information System (INIS)
The growth of a middle ear cholesteatoma behind a normal tympanic membrane is a rate though possible event. In such cases, CT may provide useful information for diagnosis. The results are presented of a CT study carried out on 14 patients affected with unilateral conductive hearing loss and with normal tympanic membrane. CT allowed the diagnosis of meddle ear cholesteatoma to be made in all cases. All patients were treated with surgery: 8 of them underwent tympanoplasty and 6 explorative tympanotomy. While the diagnosis of cholesteatoma was confirmed in 13 patients, in 1 case tympanosclerosis was diagnosed. CT diagnosis of middle ear cholesteatoma is based on the demonstration of a low-density soft-tissue mass, in association with bone erosion or ossicular dislocation. The author emphasizes the difficulty of a CT diagnosis of cholesteatoma in the patients with middle ear soft-tissue ...
1991-01-01
EXPLORENEOs. I. DESCRIPTION AND FIRST RESULTS FROM THE WARM SPITZER NEAR-EARTH OBJECT SURVEY
International Nuclear Information System (INIS)
We have begun the ExploreNEOs project in which we observe some 700 Near-Earth Objects (NEOs) at 3.6 and 4.5 ?m with the Spitzer Space Telescope in its Warm Spitzer mode. From these measurements and catalog optical photometry we derive albedos and diameters of the observed targets. The overall goal of our ExploreNEOs program is to study the history of near-Earth space by deriving the physical properties of a large number of NEOs. In this paper, we describe both the scientific and technical construction of our ExploreNEOs program. We present our observational, photometric, and thermal modeling techniques. We present results from the first 101 targets observed in this program. We find that the distribution of albedos in this first sample is quite broad, probably indicating a wide range of compositions within the NEO population. Many objects smaller than 1 km have high albedos ...
2010-09-01
Cavitation during hot-torsion testing of Ti-6Al-4V
Hot-torsion testing was used to establish the cavitation behavior of a typical alpha/beta titanium alloy, Ti-6Al-4V, with a colony microstructure, during simple-shear deformation. For this purpose, sections of deformed specimens were examined by optical metallography, and by scanning and orientation-imaging microscopy (OIM). It was found that cavity nucleation occurred along prior beta boundaries as well as at triple points; in particular, most cavities nucleated along boundaries perpendicular to the axial direction of the specimen. Extensive growth was observed for cavities surrounded by both hard and soft orientations, with the soft colonies accommodating more of the imposed strain. At high degrees of deformation, dynamic globularization of the colony microstructure adjacent to the cavities was also observed. In addition, the metallographic observations revealed that the cavities did not grow in an equiaxed mode, but in ...
2005-12-01
Strong and Tunable Nonlinear Optomechanical Coupling in a Low-Loss System
A major goal in optomechanics is to observe and control quantum behavior in a system consisting of a mechanical resonator coupled to an optical cavity. Work towards this goal has focused on increasing the strength of the coupling between the mechanical and optical degrees of freedom; however, the form of this coupling is crucial in determining which phenomena can be observed in such a system. Here we demonstrate that avoided crossings in the spectrum of an optical cavity containing a flexible dielectric membrane allow us to realize several different forms of the optomechanical coupling. These include cavity detunings that are (to lowest order) linear, quadratic, or quartic in the membrane's displacement, and a cavity finesse that is linear in (or independent of) the membrane's displacement. All these couplings are realized in a single device with extremely low optical loss and can be tuned over a wide range in situ; in particular, we ...
2010-01-01
Spin-polarized Auger-electron diffraction study of the magnetic poisoning of Fe(001) by sulfur
International Nuclear Information System (INIS)
Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.
Plain radiographic predictors of survival in treated Ewing's sarcoma
International Nuclear Information System (INIS)
We analyzed 16 radiographic features of primary Ewing's sarcoma in 342 patients from the IESS 7299 (Intergroup Ewing's Sarcoma Study) for prognostic significance. Of these, 3 features demonstrated a statistically significant relationship to survival: maximal tumor dimension, tumor location, and an appearance of honeycombing within the lesion. Those individuals with primary lesions centered in the pelvis, femur, or humerus had a worse survival rate than those with lesions centered elsewhere. Similarly, we observed an inverse relationship between the greatest dimension of the osseous portion of the lesion and survival. The radiographic finding of honeycombing also showed a statistical association with improved survival. However, this feature was observed infrequently, and its significance should be assessed further. Otherwise, no other feature that we analyzed showed any relationship to patient prognosis. (orig.).
Metal work function tuning with new molecular acceptors
Energy Technology Data Exchange (ETDEWEB)
The interfaces between metal electrodes and electroactive organic materials are important for the performance of organic electronic devices. One way of optimizing the anode/organic interface is the insertion of a (sub-)monolayer of molecular acceptors. Here we present an UPS study of new electron acceptor molecules deposited on Au(111), Cu(111) and Ag(111). This study intends to improve the understanding of how the interactions of specific electron withdrawing groups with metal surfaces are correlated with observed modifications of interfacial electron density distribution, work function change ({delta}{phi}), and the energy level alignment. We find that {delta}{phi}, which is the difference between the work function ({phi}) of the clean metal surface and {phi} after formation of a molecular monolayer, is a monotonic function of initial {phi} of the metal. Two different slopes were observed for acceptors with cyano and ...
2008-07-01
Drift- or Fluctuation-Induced Ordering and Self-Organization in Driven Many-Particle Systems
According to empirical observations, some pattern formation phenomena in driven many-particle systems are more pronounced in the presence of a certain noise level. We investigate this phenomenon of fluctuation-driven ordering with a cellular automaton model of interactive motion in space and find an optimal noise strength, while order breaks down at high(er) fluctuation levels. Additionally, we discuss the phenomenon of noise- and drift-induced self-organization in systems that would show disorder in the absence of fluctuations. In the future, related studies may have applications to the control of many-particle systems such as the efficient separation of particles. The rather general formulation of our model in the spirit of game theory may allow to shed some light on several different kinds of noise-induced ordering phenomena observed in physical, chemical, biological, and socio-economic systems (e.g., attractive and ...
2002-01-01
Differential diagnosis of rheumatic diseases; Differenzialdiagnose rheumatischer Erkrankungen
Energy Technology Data Exchange (ETDEWEB)
Which imaging modalities are appropriate for the Differential diagnosis of Rheumatic diseases. MRI has far most the highest sensitivity and is unequaled in its brilliant presentation of Anatomy and Pathology. But it is sometimes forgotten, that this is at least in part the result of carefully selected sequences, dedicated to the expected result. In a method totally independent of any result, this should not be the case. In contrary this method should be highly standardised and regardless what will be the findings. This is true for Plain X-ray. It will be shown, that already the outer silhouette of the soft parts with different features of swelling, and differences in density and even more - defects or appositions of the bony silhouette in the majority of cases at least will allow to classify the patient for a group of diseases and in many cases will lead to a definite diagnosis. Differential diagnoses like Rheumatoid Arthritis versus Psoriatic Arthritis or simply ...
2006-05-15
Cranial MRI of neurologically impaired children suffering from neonatal hypoglycaemia
International Nuclear Information System (INIS)
Background. Metabolic disturbances such as anoxia and hypoglycaemia are important in causing maldevelopment of the neonatal brain. While there have been some pathology studies of the effects of neonatal hypoglycaemia on brain development, reports of MRI findings in such infants have been rare. Objectives. To describe the MRI findings in neurologically handicapped children who had suffered from neonatal hypoglycaemia and to evaluate the relationship between the neurological impairment and neonatal hypoglycaemia. Materials and methods. We retrospectively evaluated the MRI findings in eight full-term infants with neonatal symptomatic hypoglycaemia who later exhibited neurological handicap. The age at which the MRI scans were obtained ranged from 9 months to 8 years 10 months (mean 4 years 1 month, median 4 years). Results. The most striking findings were prolonged T1 weighting and T2 weighting in the ...
1999-01-01
Magnetic and thermal properties of cubic single-crystal PrCu_4Ag
International Nuclear Information System (INIS)
We succeeded in synthesizing a new cubic intermetallic compound PrCu_4Ag in a fcc structure. Measurements of X-ray diffraction, magnetic susceptibility, magnetization, specific heat, electrical resistivity, thermal expansion, and elastic constants have been performed on single crystals of PrCu_4Ag. A maximum value of #chi#(T) with a corresponding peak in C(T) suggests that an antiferromagnetic phase transition occurs at T_N=2.4 K, where a sudden decrease in #rho#_4_f(T) and a sharp peak in the thermal expansion coefficient #alpha#(T) were observed. Characteristic Curie-type softening was observed in the temperature dependence of the transverse mode for (C_1_1 - C_1_2)/2 and C_4_4 from 70 K down to T_N, which implies that the crystalline electric field (CEF) ground state is the magnetic triplet #GAMMA#_5. The anisotropic properties in M(T,H) and C(T,H) are studied when the external magnetic field is applied in the ...
2010-11-01
Multidetector-row helical CT: analysis of time management and workflow
International Nuclear Information System (INIS)
The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (#+-#2.06 min); (b) 4:36 min (#+-#2.43 min); (c) 4:11 min (#+-#2.55 min); (d) 0:43 min (#+-#0.15 min); (e) 6:59 min (#+-#2.39 min); (f) 09:51 min (#+-#3.51 min). Planning and ...
2002-03-01
Energy Technology Data Exchange (ETDEWEB)
The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen ...
1997-12-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive ...
2003-09-01
International Nuclear Information System (INIS)
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive ...
2003-09-01
International Nuclear Information System (INIS)
In a prospective study, 58 patients with carcinomas of the bladder were examined by CT and MRI; in 48, gadolinium-DTPA was administered intravenously. MRI provided exact staging in 89%, compared with 80% with CT. There was 13% over-staging with CT and 11% with MRI. MRI, unlike CT did not result in any under-staging. In 36 patients a quotient could be calculated from the signal intensity of the tumour and surrounding soft tissues both before and after the intravenous contrast medium and the increased quotient after contrast administration could be estimated. There was a significant increase in the tumour/muscle quotient with a mean of 72#+-#22% (minimum 43%, maximum 153%), corresponding to a marked increase of the signal form the tumour when compared with the precontrast images. This had the following advantages compared with CT: Accurate differentiation between superficial and ...
CT appearances of unilateral cleft palate 20 years after bone graft surgery
Energy Technology Data Exchange (ETDEWEB)
Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although ...
2002-11-01
CT appearances of unilateral cleft palate 20 years after bone graft surgery
International Nuclear Information System (INIS)
Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although ...
2002-11-01
Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemo embolization
International Nuclear Information System (INIS)
The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to globla chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower tha 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and ...
2000-06-01
Energy Technology Data Exchange (ETDEWEB)
Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow ...
1995-07-01
International Nuclear Information System (INIS)
Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow regime, void ...
1346-01-01
Energy Technology Data Exchange (ETDEWEB)
In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.) [Deutsch] In einem erweiterten Fallbericht wird ueber die vier grossen Entitaeten bei ...
1995-11-01
Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model
Energy Technology Data Exchange (ETDEWEB)
Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was ...
2007-02-15
Energy Technology Data Exchange (ETDEWEB)
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total biological response rate is 42% (n= 41) for the ...
2006-12-15
Disorders of brain development and phakomatosis
International Nuclear Information System (INIS)
Full text: Disorders of brain development and phakomatosis are resulting from disturbed embryonic-foetal development One third of all major embryological anomalies involve CNS, and over 2000 different anomalies have been described. Anomalies of the brain often cause foetal and neonatal death, and mental and physical retardation in pediatric group. The majority of disorders of brain development and phakomatosis are idiopathic, and most of them are not hereditary or familial. Ultrasonography plays the important role in screening foetal and neonatal brain, but after closure of fontanels it is difficult to find the acoustic window. CT has limited contrast resolution, and disadvantage exposing infant to ionizing radiation. It is helpful to demonstrate the presence of calcifications. MR imaging has proved to be a diagnostic tool of major importance in children with disorders of brain development and phakomatosis. The excellent grey/white matter ...
Computerized Tomography-guided fine-needle biopsy of peripheral pulmonary nodules < 2 cm in diameter
International Nuclear Information System (INIS)
The authors investigated the role of Computerized Tomography in guiding fine needle biopsy (FNB) in small (2 2 cm in diameter for CT-guided FNB sensitivity, specificity and diagnostic accuracy. Cytologic specimens were positive for malignancy in 40/52 cases (76.9%) and negative in 12 (23.1%). Clinical-surgical follow-up confirmed all the positive cytologic findings (40 cases), while 2 of the extant 12 cases were false negatives (95.20% sensitivity, 100% specificity and 96.15% diagnostic accuracy). 158 of 195 nodules > 2 cm in diameter and with clinical surgical follow-up (81.3%) were positive for malignancy and 34 were negative (17.43%) (98.75% sensitivity, 97.14% specificity and 98.46% diagnostic accuracy). Pneumothorax occurred in 33 patients (16.5%) with nodules > 2 cm in diameter as a complication of biopsy. Hemoptysis occurred in 15 patients (7.5%). In the whole group of lung lesions, the complications were pneumothorax in 80 ...
THE EVOLUTION OF CLOUD CORES AND THE FORMATION OF STARS
International Nuclear Information System (INIS)
For a number of starless cores, self-absorbed molecular line and column density observations have implied the presence of large-amplitude oscillations. We examine the consequences of these oscillations on the evolution of the cores and the interpretation of their observations. We find that the pulsation energy helps support the cores and that the dissipation of this energy can lead toward instability and star formation. In this picture, the core lifetimes are limited by the pulsation-decay timescales, dominated by non-linear mode-mode coupling, and on the order of #approx =# few x 10"5-10"6 yr. Notably, this is similar to what is required to explain the relatively low rate of conversion of cores into stars. For cores with large-amplitude oscillations, dust continuum observations may appear asymmetric or irregular. As a consequence, some of the cores that would be classified as super-critical may be ...
2010-09-20
Stellar Populations of Lyman-alpha Emitters at z=4.86: A Comparison to $z\\sim5$ LBGs
(abridged) We present a study of stellar population of LAEs at z=4.86 in GOODS-N and its flanking field. With the publicly available IRAC data in GOODS-N and further IRAC observations in the flanking fields, we select five LAEs which are not contaminated by neighboring objects in IRAC images and construct their observed SEDs with I_c, z', IRAC 3.6micron, and 4.5micron band photometry. The SEDs cover the rest-frame UV to optical wavelengths. We derive stellar masses, ages, color excesses, and star formation rates of five LAEs using SED fitting method. Assuming the constant star formation history, we find that the stellar masses range from 10^8 to $10^{10} Msun with the median value of 2.5x10^9 Msun. The derived ages range from very young ages (7.4 Myr) to 437 Myr with a median age of 25 Myr. The color excess E(B-V) are between 0.1-0.4 mag. Star formation rates are 55-209 Msun/yr. A comparison of the stellar populations is ...
2010-01-01
Single leptoquark production at e"+e- and #gamma##gamma# colliders
International Nuclear Information System (INIS)
We consider single production of leptoquarks (LQ's) at e"+e- and #gamma##gamma# colliders, for two values of the center-of-mass energy: #sq root#s =500 GeV and 1 TeV. We find that LQ's which couple within the first generation are observable for LQ masses almost up to the kinematic limit, both at e"+e- and #gamma##gamma# colliders, for an LQ coupling strength equal to #alpha#_e_m. The cross sections for single production of second- and third-generation LQ's at e"+e- colliders are too small to be observable. In #gamma##gamma# collisions, on the other hand, second-generation LQ's with masses much larger than #sq root#s /2 can be detected. However, third-generation LQ's can be seen at #gamma##gamma# colliders only for masses at most #approx# #sq root#s /2, making their observation more probable via the pair production mechanism.
Orbital roulette: a new method of gravity estimation from observed motions
The traditional way of estimating the gravitational field from observed motions of test objects is based on the virial relation between their kinetic and potential energy. We find a more efficient method. It is based on the natural presumption that the objects are observed at a random moment of time and therefore have random orbital time phases. The proposed estimator, which we call "orbital roulette", checks the randomness of the phases. The method has the following advantages: (1) It estimates accurately Keplerian (point-mass) potentials as well as non-Keplerian potentials where the unknown gravitating mass is distributed in space. (2) It is a complete statistical estimator: it checks a trial potential and accepts it or rules it out with a certain significance level; the best-fit measurement is thus supplemented with error bars at any confidence level. (3) It needs no a priori assumptions about the distribution of orbital ...
2004-01-01
KINEMATICS AT THE EDGE OF THE GALACTIC BULGE: EVIDENCE FOR CYLINDRICAL ROTATION
International Nuclear Information System (INIS)
We present new results from BRAVA, a large-scale radial velocity survey of the Galactic bulge, using M giant stars selected from the Two Micron All Sky Survey catalog as targets for the Cerro Tololo Inter-American Observatory 4 m Hydra multi-object spectrograph. The purpose of this survey is to construct a new generation of self-consistent bar models that conform to these observations. We report the dynamics for fields at the edge of the Galactic bulge at latitudes b = -8 deg. and compare to the dynamics at b = -4 deg. We find that the rotation curve V(r) is the same at b = -8 deg. as at b = -4 deg. That is, the Galactic boxy bulge rotates cylindrically, as do boxy bulges of other galaxies. The summed line-of-sight velocity distribution at b = -8 deg. is Gaussian, and the binned longitude-velocity plot shows no evidence for either a (disk) population with cold dynamics or for a (classical bulge) population with hot dynamics. The ...
2009-09-10
Independent Emission and Absorption Abundances for Planetary Nebulae
Emission-line abundances have been uncertain for more than a decade due to unexplained discrepancies in the relative intensities of the forbidden lines and weak permitted recombination lines in planetary nebulae (PNe) and H II regions. The observed intensities of forbidden and recombination lines originating from the same parent ion differ from their theoretical values by factors of more than an order of magnitude in some of these nebulae. In this study we observe UV resonance line absorption in the central stars of PNe produced by the nebular gas, and from the same ions that emit optical forbidden lines. We then compare the derived absorption column densities with the emission measures determined from ground-based observations of the nebular forbidden lines. We find for our sample of PNe that the collisionally excited forbidden lines yield column densities that are in basic agreement with the column ...
2008-01-01
Different Evolutionary Stages in the Massive Star Forming Region S255 Complex
To understand evolutionary and environmental effects during the formation of high-mass stars, we observed three regions of massive star formation at different evolutionary stages that reside in the same natal molecular cloud. Methods. The three regions S255IR, S255N and S255S were observed at 1.3 mm with the Submillimeter Array (SMA) and followup short spacing information was obtained with the IRAM 30m telescope. Near infrared (NIR) H + K-band spectra and continuum observations were taken for S255IR with VLT-SINFONI to study the different stellar populations in this region. The combination of millimeter (mm) and near infrared data allow us to characterize different stellar populations within the young forming cluster in detail. While we find multiple mm continuum sources toward all regions, their outflow, disk and chemical properties vary considerably. The most evolved source S255IR exhibits a ...
2010-01-01
Steam generator local water chemistry and SCC of austenitic steel
Energy Technology Data Exchange (ETDEWEB)
The titanium stabilized austenitic steel similar to the type of 321 is sensitive to the stress corrosion crackingunder horizontal steam generator operating condition. SCC was observed under crevice corrosion parameters and has resulted in the transgranular or intergranular cracking at the both, components primary collectors and heat exchange tubes. The crevice environment is characterized by aggressive impurities and 'non aggressive' compounds. Sulfates and chlorides as aggressive species and silicates and alumino-silicates as 'non aggressive' species on the other hand are present in significant amount in the crevice environment under operating condition. Local water chemistry parameters were evaluated with MULTEQ Code. As input data the measured operational values of local and bulk environments have been used. The determined parameters were compared with the results of thread hole environment analyses and tube surface ...
1998-07-01
The Next Linear Collider: NLC2001
Energy Technology Data Exchange (ETDEWEB)
Recent studies in elementary particle physics have made the need for an e{sup +}e{sup -} linear collider able to reach energies of 500 GeV and above with high luminosity more compelling than ever [1]. Observations and measurements completed in the last five years at the SLC (SLAC), LEP (CERN), and the Tevatron (FNAL) can be explained only by the existence of at least one particle or interaction that has not yet been directly observed in experiment. The Higgs boson of the Standard Model could be that particle. The data point strongly to a mass for the Higgs boson that is just beyond the reach of existing colliders. This brings great urgency and excitement to the potential for discovery at the upgraded Tevatron early in this decade, and almost assures that later experiments at the LHC will find new physics. But the next generation of experiments to be mounted by the world-wide particle physics community must not only ...
2002-01-14
Clinical MR mammography. Impact of hormonal status on background enhancement and diagnostic accuracy
Energy Technology Data Exchange (ETDEWEB)
Purpose: Hormonal stimulation can induce background enhancement (BE) in MR mammography (MRM). This fact has been assumed to decrease the accuracy of MRM. Consequently, this report investigates: 1. The prevalence of BE in postmenopausal vs. premenopausal women in correlation to hormonal cycle phase (CP). 2. The impact of hormonal status (HS) and BE on diagnostic accuracy. Materials and Methods: Consecutive patients over 22 months with complete HS information (week of CP or postmenopausal) were included in this prospective investigation. Exclusion criteria were any hormonal therapy, hysterectomy as well as cancer proven by biopsy. The standard of reference was histopathology. All MRM scans were acquired using the same protocol (1.5 T, dynamic T 1w GRE after 0.1 mmol/kg bw Gd-DTPA i. v.). Two radiologists rated all examinations in consensus according to BI-RADS. BE was defined as: 0 = missing, 1 = moderate, 2 = distinct. Results: 224 patients (150 postmenopausal, 74 premenopausal, 45 in ...
2011-05-15
High resolution Computed Tomography in the study of temporal bone trauma
International Nuclear Information System (INIS)
Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution ...
1988-01-01
Computed tomography (CT) in renal trauma
International Nuclear Information System (INIS)
CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of ...
1987-01-01
Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases
International Nuclear Information System (INIS)
As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive ...
1990-01-01
The value of computed tomography in the diagnosis of grating scapula
Energy Technology Data Exchange (ETDEWEB)
Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)
1994-07-01
Synovial cysts of the lumbar spine: CT and MRI correlations
Energy Technology Data Exchange (ETDEWEB)
Intraspinal synovial cysts were diagnosed in six patients during a 5-year period and retrospectively studied. Plain films of the lumbar spine showed degenerative changes in all patients. Lumbar myelography showed a posterior and lateral defect caused by extradural compression. Using CT without contrast enhancement established the diagnosis in five of the six patients. In four cases MRI was performed, three before and after injection of gadolinium diethyline-triamine penta-acetic acid (Gd-DTPA). Including the patient with a false-negative CT, MRI was positive in all patients. (orig.)
1994-08-01
Energy Technology Data Exchange (ETDEWEB)
A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated ...
2004-12-01
Ovarial tumours in the CT image - correlation of histology and CT diagnosis
Energy Technology Data Exchange (ETDEWEB)
The value of CT in respect of preoperative determination of tumour status and of tumour classification was studied using 127 histologically identified ovarial tumours as basis in a blind study via mutual image classification by the two participating institutes. The medium accuracy of diagnosis was 82%, but the results were found to be greatly dependent on tumour histology. Quotas of more than 90% were obtained in case of functional cysts, cystomas, cystadeno-carcinomas and dermoids, whereas classification was less successful with the other types of tumours such as germ cell tumours, tumours of the sexually differentiated stroma, metastases and tubo-ovarial abscesses.
1984-04-01
Dentascan CT of mandibular incisive canal. Radiological anatomy and therapeutic implications
International Nuclear Information System (INIS)
The main purpose of this paper is to stress the importance of CT depiction of the mandibular incisive canal. This anatomical structure contains a major neurovascular bundle and is thus very important in the planning of mandibular implants in the canine-incisive area. The importance of careful assessment of the mandibular canal course before implantology is now widely recognized. The same holds true for the canine-incisive region in the jaw, to detect the incisive canal if present and prevent any complications from its accidental damage. CT with a dedicated software showed the incisive canal in a large number of patients, which calls for precise reporting of its presence, course, and relationships with teeth.
1999-11-01
The effect of patient positioning aids on PET quantification in PET/MR imaging
British Library Electronic Table of Contents (United Kingdom)
Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...
2011-01-01
Structure and Characterization of Nicotinic Acetylcholine ...
... the ct-neurotoxin from Dendroaspis viridis venom (a-DTX) , which binds to four sites on the AcChR molecule (Conti-Tronconi & Raftery 1986). ...
1991-11-07
Individually adapted examination protocols for reduction of radiation exposure in chest CT
International Nuclear Information System (INIS)
Feb 2002 p. 301 Germany Wildberger, JE Mahnken, AH Schmitz-Rode, T.
2002-02-01
International Nuclear Information System (INIS)
1980. p. 94. Bulgaria Stargardt, A. Institut fuer Roentgendiagnostik, Charite,
Identification and staging of bladder carcinoma
International Nuclear Information System (INIS)
The purpose of the present study was to compare the effectiveness of MRI, CT and radioimmunoscintigraphy in the staging and detection of bladder cancers in 28 patients. We distinguish two groups: Group I included the tumour stages CIS-T_3_A and the second group the deep infiltrative tumours T_3_B-T_4. MRI was slightly superior to CT in respect of tumour staging (75% correct results as compared to 63%). No understaging occurred with MRI, whereas in 22% of the cases the stage of the tumour was underestimated using CT diagnostics. Overstaging occurred in 25% of the MRI and 15% of the CT-diagnostics, respectively. RIS cannot distinguish the tumour groups, and hence this method is useful only for the detection of the primary tumour and metastases. In 77% of cases the tumour was detected and in 15% the tumour could be safely excluded. (orig.).
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
COBAS AMPLICOR CT/NG Test for Neisseia gonorrhoeae Package Insert
... The thermostable Thermus aquaticus DNA polymerase, (Taq pol), in the presence of excess deoxynucleoside triphosphates (dNTPs), including deoxyadenosine ...
Energy Technology Data Exchange (ETDEWEB)
Progressive multifocal leukoencephalopathy (PML) is a demyelinating disease of the central nervous system caused by the JC virus (JCV), a human papovavirus. PML is a relatively rare disease seen predominantly in immunocompromised individuals and is a frequent complication observed in AIDS patients. The significantly higher incidence of PML in AIDS patients than in other immunosuppressive disorders has suggested that the presence of human immunodeficiency virus type 1 (HIV-1) in the brain may directly or indirectly contribute to the pathogenesis of this disease. In the present study the authors have examined the expression of the JCV genome in both glial and non-glial cells in the presence of HIV-1 regulatory proteins. They find that the HIV-1-encoded trans-regulatory protein tat increases the basal activity of the JCV late promoter, JCV{sub L}, in glial cells. They conclude that the presence of the HIV-1-encoded tat protein may positively ...
1990-05-01
The Mid-Infrared Narrow Line Baldwin Effect Revealed by Spitzer
We present our discovery of a narrow-line Baldwin effect, an anti-correlation between the equivalent width (EW) of a line and the flux of the associated continuum, in 5-20$\\mu$m mid-infared lines from a sample of 68 Active Galactic Nuclei (AGN), located at z$<$0.5, observed with the Infrared Spectrograph on the {\\it Spitzer Space Telescope}. Our analysis reveals a clear anti-correlation between the EW of the [SIV] 10.51$\\mu$m, [NeII] 12.81$\\mu$m, and [NeIII] 15.56$\\mu$m lines and their mid-IR continuum luminosities, while the Baldwin effect for [NeV] 14.32$\\mu$m is not as obvious. We suggest that this anti-correlation is driven by the central AGN and not circumnuclear star formation in the host galaxy. We also find that the slope of the narrow-line Baldwin effect in the mid-infrared does not appear to steepen with increasing ionization potential. Examining the dependence of the EW to the Eddington Ratio ($L/L_{Edd}$) we ...
2008-01-01
Star Formation Activities of Galaxies in the Large-Scale Structures at z=1.2
Recent wide-field imaging observations of the X-ray luminous cluster RDCSJ1252.9-2927 at z=1.24 uncovered several galaxy groups that appear to be embedded in filamentary structure extending from the cluster core. We make a spectroscopic study of the galaxies in these groups using GMOS on Gemini-South and FORS2 on VLT with the aim of determining if these galaxies are physically associated to the cluster. We find that three groups contain galaxies at the cluster redshift and that they are probably bound to the cluster. This is the first confirmation of filamentary structure as traced by galaxy groups at z>1. We then use several spectral features in the FORS2 spectra to determine the star formation histories of group galaxies. We find a population of relatively red star-forming galaxies in the groups that are absent from the cluster core. While similarly red star forming galaxies can also be found in the field, the average ...
2009-01-01
International Nuclear Information System (INIS)
Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal findings can ...
1988-08-15
Energy Technology Data Exchange (ETDEWEB)
In 10 cases of femoral neck fracture treated with prosthetic replacement, the preoperative sup(99m)Tc-MDP scintigraphs were investigated and then compared with each histological findings of the extracted femoral head. The appearances of the scintigraphs were classified into following 3 patterns; increased activity pattern of sup(99m)Tc-MDP uptake in the overall femoral head (type I) in 4 cases, deficient activity pattern at the lateral side correspond to weight-bearing area (type II) in 2 cases and considerably deficient activity pattern in the whole femoral head (type III) in remaining 4 cases. Histological examination of the extracted femoral heads revealed the narrow part of ischemic necrosis in type I. However type II showed extensive necrosis in the portion of deficient activity by scintigraphs and in type III, the femoral heads except articular cartilage were entirely necrotic. This classification of sup(99m)Tc-MDP scintigraphy is correlated with the degree ...
1984-06-01
QoS-Aware Joint Policies in Cognitive Radio Networks
One of the most challenging problems in Opportunistic Spectrum Access (OSA) is to design channel sensing-based protocol in multi secondary users (SUs) network. Quality of Service (QoS) requirements for SUs have significant implications on this protocol design. In this paper, we propose a new method to find joint policies for SUs which not only guarantees QoS requirements but also maximizes network throughput. We use Decentralized Partially Observable Markov Decision Process (Dec-POMDP) to formulate interactions between SUs. Meanwhile, a tractable approach for Dec-POMDP is utilized to extract sub-optimum joint policies for large horizons. Among these policies, the joint policy which guarantees QoS requirements is selected as the joint sensing strategy for SUs. To show the efficiency of the proposed method, we consider two SUs trying to access two-channel primary users (PUs) network modeled by discrete Markov chains. Simulations demonstrate three ...
2010-01-01
Observation of the Far-ultraviolet Continuum Background with SPEAR/FIMS
We present the general properties of the far-ultraviolet (FUV; 1370-1720A) continuum background over most of the sky, obtained with the Spectroscopy of Plasma Evolution from Astrophysical Radiation instrument (SPEAR, also known as FIMS), flown aboard the STSAT-1 satellite mission. We find that the diffuse FUV continuum intensity is well correlated with N_{HI}, 100 $\\mu$m, and H-alpha intensities but anti-correlated with soft X-ray. The strongest correlation is with the H-alpha emission, and the correlation of the diffuse background with the direct stellar flux is weaker than the correlation with other parameters. The continuum spectra are relatively flat. However, a weak softening of the FUV spectra toward some sight lines, mostly at high Galactic latitudes, is found not only in direct-stellar but also in diffuse background spectra. The diffuse background is relatively softer that the direct stellar spectrum. We also find that the diffuse FUV ...
2010-01-01
We analyze cross sections for quasielastic inclusive scattering of electrons on nuclei and show that the observed isolated peaks for relatively low Q{sup 2} are unique for the lightest targets. Focusing, in particular, on D and {sup 4}He, we investigate in two ways to what measure the above peaks can be allocated to nucleon-elastic processes. We first compute approximate upper limits for the nucleon-inelastic background in the quasielastic region due to inclusive {delta} excitation, and find those to be small. Far more precise is a semiphenomenological approach, where the dominance of nucleon-elastic processes is translated into a set of stringent requirements. We show that those are very well fulfilled for recent D data, and to a somewhat lesser extent for older D and {sup 4}He data. With knowledge of G{sub E,M}{sup p} and information on G{sub E}{sup n}, we then extract G{sub M}{sup n} and find agreement with values ...
2004-07-01
Neutron magnetic form factor G_M"n(Q"2) from quasielastic inclusive scattering data on D and "4He
International Nuclear Information System (INIS)
We analyze cross sections for quasielastic inclusive scattering of electrons on nuclei and show that the observed isolated peaks for relatively low Q"2 are unique for the lightest targets. Focusing, in particular, on D and "4He, we investigate in two ways to what measure the above peaks can be allocated to nucleon-elastic processes. We first compute approximate upper limits for the nucleon-inelastic background in the quasielastic region due to inclusive #DELTA# excitation, and find those to be small. Far more precise is a semiphenomenological approach, where the dominance of nucleon-elastic processes is translated into a set of stringent requirements. We show that those are very well fulfilled for recent D data, and to a somewhat lesser extent for older D and "4He data. With knowledge of G_E_,_M"p and information on G_E"n, we then extract G_M"n and find agreement with values obtained by alternative methods. We discuss the ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
Use of hydrogen in large scale applications is more usual than public is mentioning normally. Nevertheless reserve against hydrogen can be observed up to highest level decision-makers. Possibly a main reason can be found and eliminated by fixing: Some spectacular accidents happened in the past and found great interest. The publication of impressive accidents and the follow up of the events course was very carefully. The research in finding causalities in former decisions and follow up was not in the interest of some people or institutions. Important facts are even not noticed by insiders, but would have been very important for future decision makings and public acceptance of new applications. It will be demonstrated in three historical examples. Much more examples would be available and each one could help to find new applications for a saver and effective use of hydrogen in power supply. Awaking from new reserves could be ...
2001-07-01
Ly-alpha emitters: blue dwarfs or supermassive ULIRGs? Evidence for a transition with redshift
The traditional view that Ly-alpha emission and dust should be mutually exclusive has been questioned more and more often, notably the observations of Ly-alpha emission from ULIRGs seems to counter this view. In this paper we seek to address the reverse question: How large a fraction of Ly-alpha selected galaxies are ULIRGs? Using two samples of 24/25 Ly-alpha emitting galaxies at z = 0.3/2.3 we perform this test, also including results at z = 3.1, and find that whereas the ULIRG fraction at z = 3.1 is very small, it systematically increases towards lower redshifts. There is a hint that this evolution may be quite sudden and that it happens around a redshift of z ~ 2.5. Measuring the infrared luminosities of the Ly-alpha emitters, we find that they are in the normal to ULIRG range in the lower redshift sample, whereas the higher redshift galaxies all have luminosities in the ULIRG category. The Ly-alpha escape fractions for ...
2009-01-01
An empirical comparison of alternate regime-switching models for electricity spot prices
International Nuclear Information System (INIS)
One of the most profound features of electricity spot prices are the price spikes. Markov regime-switching (MRS) models seem to be a natural candidate for modeling this spiky behavior. However, in the studies published so far, the goodness-of-fit of the proposed models has not been a major focus. While most of the models were elegant, their fit to empirical data has either been not examined thoroughly or the signs of a bad fit ignored. With this paper we want to fill the gap. We calibrate and test a range of MRS models in an attempt to find parsimonious specifications that not only address the main characteristics of electricity prices but are statistically sound as well. We find that the best structure is that of an independent spike 3-regime model with time-varying transition probabilities, heteroscedastic diffusion-type base regime dynamics and shifted spike regime distributions. Not only does it allow for a seasonal spike intensity ...
2010-09-01
17- and 24-GHz observations of southern pulsars
We present observations of PSRs J0437-4715, J0738-4042, J0835-4510, J0908-4913, J1048-5832, J1622-4950, J1644-4559, J1721-3532 and J1740-3015 at 17 GHz using the Parkes radio telescope. All nine were detected at 17 GHz, additionally, we detected PSR J0835-4510 and J1622-4950 at 24 GHz. Polarization profiles of each pulsar and the variation with frequency are discussed. In general, we find that the highly polarized edge components of young pulsars continue to dominate their profiles at 17 GHz. Older pulsars (?105 yr) appear to be almost completely depolarized. Our detection of PSR J0437-4715 is the highest frequency observation of a millisecond pulsar to date, and implies a luminosity at 17 GHz of 14 ?Jy kpc2, and a mean spectral index of 2.2. We find that the spectral index of the magnetar PSR J1622-4950 is flat between 1.4 and 24 GHz, similar to the other known radio magnetars XTE J1810-197 and 1E ...
2011-06-01
Energy Technology Data Exchange (ETDEWEB)
Radon concentration measurements in atmosphere were taken in years from 1997 to 1999 in Milan and at pre-alpine sites located north of Lombardy. In this paper the results of measuring campaigns and a comparison of radon levels observed in the hilly area north of the town and on the pre-Alps are reported. The general criteria of the measurements and the interpretative models of radon concentration are presented. The Lake Maggiore area shows evidence of a great nocturnal stability and frequent formation of Nocturnal Stable Layer. The peculiar findings in the high altitude stations confirm the use of radon as an indicator of atmospheric dispersion of pollutants in an area with complex orography. The afternoon minimum values are concordant for the different stations: this implies a remixing in afternoon hours over the whole area investigated.
2006-07-01
Use of a novel acoustic dissolved oxygen transmitter for fish telemetry
DEFF Research Database (Denmark)
The multiple responses of fishes to changes in dissolved oxygen saturations have been studied widely in the laboratory. In contrast only few studies have included field observations. The objective of the present study was to evaluate the performance of a novel acoustic dissolved oxygen transmitter for field biotelemetry. The results demonstrated that the output of the transmitter was unaffected by three different temperatures (10 to 30 degrees C) and described the dissolved oxygen saturation with high accuracy (r(2) > 0.99) over the entire range of 0 to 191% saturation. The response time (>= 90% of end value) of the transmitter was 12 s both in terms of decreasing (100 to 0%) and increasing (0 to 100%) oxygen saturations. When externally attached to fishes the present findings support the use of the transmitter for reliable dissolved oxygen measurements on individuals living in environments that may change both temporally and spatially ...
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract We address the fundamental question of matching the rest-frame K-band luminosity function (LF) of galaxies over the Hubble time using semi-analytic models after modification of the stellar population modelling. We include the Maraston evolutionary synthesis models, which feature a higher contribution by the thermally pulsating asymptotic giant branch (TP-AGB) stellar phase, into three different semi-analytic models, namely the De Lucia and Blaizot version of the Munich model, morgana and the Menci model. We leave all other input physics and parameters unchanged. We find that the modification of the stellar population emission can solve the mismatch between models and the observed rest-frame K-band luminosity from the brightest galaxies derived from UKIRT Infrared Deep Sky Survey d...
2011-01-01
The Cosmological Constant and Lorentz Invariance of the Vacuum State
One hope to solve the cosmological constant problem is to identify a symmetry principle, based on which the cosmological constant can be reduced either to zero, or to a tiny value. Here, we note that requiring that the vacuum state is Lorentz invariant significantly reduces the theoretical value of the vacuum energy density. Hence, this also reduces the discrepancy between the observed value of the cosmological constant and its theoretical expectation, down from 123 orders of magnitude to 56 orders of magnitude. We find that, at one loop level, massless particles do not yield any contribution to the cosmological constant. Another important consequence of Lorentz symmetry is stabilization of the gravitational hierarchy: the cosmological constant (divided by Newton's constant) does not run as the quartic power of the renormalization group scale, but instead only logarithmically.
2011-01-01
Split anterior tibial tendon transfer for varus equinus spastic foot deformity
British Library Electronic Table of Contents (United Kingdom)
Spastic equinovarus foot deformity commonly occurs after stroke or head trauma. Management by split anterior tibial tendon transfer to the lateral border of the foot was chosen by the authors. The purpose of that work was to assess the reliability of this method to improve patient's functional autonomy and investigate the relationship between the initial clinical examination findings and the quality of the functional results. 84 feet, operated in 82 patients out of 130, of mean age 46 years, were reviewed at a mean follow-up of 65 months. Very few complications were observed. Toe deformities remain a commonly associated problem. 80 patients were able to walk barefoot, 74 reported an increase in their walking distance, and 73 could regularly wear normal shoes. There is a strong relationship...
2011-01-01
Social class, social mobility and mortality in the Netherlands, 1850-2004
British Library Electronic Table of Contents (United Kingdom)
This study uses data from a random sample of births in the Netherlands during the period 1850-1922 to examine the relationships between social class, social mobility and mortality at middle and old age. Population registers and personal cards covering the period from 1850 to 2004 for all Dutch provinces were used to reconstruct individual life histories of 14,900 births. For men we did not find an effect of the social class of origin (using two different SES-classifications) on mortality in age group 18 to 35. We also did not observe an effect of own social class on mortality after age 35. For women effects of social class of origin and social class of husband were generally absent as well. Our conclusion is that the standard ideas about the negative effects of processes of industrializati...
2011-01-01
Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR
International Nuclear Information System (INIS)
This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)
2006-11-13
SPH simulations of accretion flow via Roche lobe overflow and via mass transfer from Be disk
We compare the accretion flow onto the neutron star induced by Roche lobe overflow with that by the overflow from the Be disk, in a zero eccentricity, short period binary with the same mass transfer rate, performing three-dimensional Smoothed Particle Hydrodynamics simulations. We find that a persistent accretion disk is formed around the neutron star in both cases. The circularization radius of the material transferred via Roche lobe overflow is larger than that of the material transfered from the Be disk. Thus, the growth of the accretion disk in the former case becomes significantly slower than in the latter case. In both cases, the mass accretion rate is very small and varies little with orbital phase, which is consistent with the observed X-ray behaviour of Be/X-ray binaries with circular orbits (e.g. XTE J1543-568).
2005-01-01
Role of Fgf receptor 2c in adipocyte hypertrophy in mesenteric white adipose tissue
British Library Electronic Table of Contents (United Kingdom)
Fgf receptor 2c (Fgfr2c) was expressed in mature adipocytes of mouse white adipose tissue (WAT). To examine the role of Fgfr2c in mature adipocytes, we generated adipocyte-specific Fgfr2 knockout (Fgfr2 CKO) mice. The hypertrophy impairment of adipocytes in the mesenteric WAT but not in the subcutaneous WAT and decreased plasma free fatty acid (FFA) levels were observed in Fgfr2 CKO mice. Although the expression of genes involved in adipocyte differentiation and lipid metabolism in the mesenteric WAT was essentially unchanged, the expression of uncoupling protein 2 potentially involved in energy dissipation was significantly increased. Among potential Fgf ligands for Fgfr2c, Fgf9 was preferentially expressed in the mesenteric WAT. The present findings indicate that Fgfr2c potentially activ...
2008-01-01
Relativistic D-brane scattering is extremely inelastic
Energy Technology Data Exchange (ETDEWEB)
We study the effects of quantum production of open strings on the relativistic scattering of D-branes. We find strong corrections to the brane trajectory from copious production of highly-excited open strings, whose typical oscillator level is proportional to the square of the rapidity. In the corrected trajectory, the branes rapidly coincide and remain trapped in a configuration with enhanced symmetry. This is a purely stringy effect which makes relativistic brane collisions exceptionally inelastic. We trace this effect to velocity-dependent corrections to the open string mass, which render open strings between relativistic D-branes surprisingly light. We observe that pair-creation of open strings could play an important role in cosmological scenarios in which branes approach each other at very high speeds. (author)
2005-02-01
Proton-proton scattering above 3 GeV/c
Energy Technology Data Exchange (ETDEWEB)
A large set of data on proton-proton differential cross sections, analyzing powers and the double-polarization parameter A{sub NN} is analyzed employing the Regge formalism. We find that the data available at proton beam momenta from 3GeV/c to 50GeV/c exhibit features that are very well in line with the general characteristics of Regge phenomenology and can be described with a model that includes the {rho}, {omega}, f{sub 2}, and a{sub 2} trajectories and single-Pomeron exchange. Additional data, specifically for spin-dependent observables at forward angles, would be very helpful for testing and refining our Regge model. (orig.)
2010-09-15
Properties and physiological effects of thermal carbon black.
Studies have been carried out to determine the possible physiological effects of contact with carbon black made by the thermal process. Contact was made by ingestion, skin application and/or inhalation. Ingestion and/or skin application do not appear to lead to any changes from the normal. Inhalation exposures do not produce pulmonary function changes (antemortem or postmortem studies) but may lead to moderate to severe "perifocal" emphysema in Rhesus monkeys (not observed in guinea pigs). Inhalation studies also suggest right ventricular septal and to a degree, left ventricular hypertrophy in Rhesus monkeys as an effect. Additional studies are necessary to support these finding and consideration must be given to the variability among exposed subjects as compared to controls. PMID:136503
1976-11-01
Probing Student Understanding of Scientific Thinking in the Context of Introductory Astrophysics
Common forms of testing of student understanding of science content can be misleading about their understanding of the nature of scientific thinking. Observational astronomy integrated with related ideas of force and motion is a rich context to explore the correlation between student content knowledge and student understanding of the scientific thinking about that content. In this paper, we describe this correlation in detail with a focus on a question about the relative motion of the Sun and the Earth. We find that high achieving high school students throughout New York City struggle with what constitutes scientific justification and thought processes, but can improve these skills tremendously in an inquiry-oriented summer astronomy-physics program. (Contains 3 tables and 4 figures.)
2008-12-01
Predictability, complexity and learning
We define {\\em predictive information} $I_{\\rm pred} (T)$ as the mutual information between the past and the future of a time series. Three qualitatively different behaviors are found in the limit of large observation times $T$: $I_{\\rm pred} (T)$ can remain finite, grow logarithmically, or grow as a fractional power law. If the time series allows us to learn a model with a finite number of parameters, then $I_{\\rm pred} (T)$ grows logarithmically with a coefficient that counts the dimensionality of the model space. While logarithmic growth of related information theoretic quantities has been found in previous work on learning, power law growth has not been seen in this context. We find that it is associated, for example, with the learning of infinite parameter (or nonparametric) models such as continuous functions with smoothness constraints. There are connections between the predictive information and measures of complexity that have been ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in {gamma}{gamma}{yields}t t-bar {yields}lX/bX for various beam polarizations in order to study possible anomalous t t-bar {gamma}, tbW and {gamma}{gamma}H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and {gamma}{gamma} colliders from the viewpoint of the anomalous-top-quark-coupling determination.
2005-11-15
Optimal beam polarizations for new-physics search through #gamma##gamma##->#t t-bar #->#lX/bX
International Nuclear Information System (INIS)
We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in #gamma##gamma##->#t t-bar #->#lX/bX for various beam polarizations in order to study possible anomalous t t-bar #gamma#, tbW and #gamma##gamma#H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and #gamma##gamma# colliders from the viewpoint of the anomalous-top-quark-coupling determination.
2005-11-01
Modulation of proton NMR free induction decay by spin diffusion
Energy Technology Data Exchange (ETDEWEB)
The effects of spin diffusion on the free induction decay (FID) of protons associated with the noncrystalline domains of two polymers, polyethylene and blended Nylon 66 (ZYTEL-408), have been examined using Goldman--Shen NMR pulse sequence ((1/2)..pi..x-t/sub 0/-(1/2)..pi..x-bar-tau-(1/2)..pi..x-t). At tau< or approx. =100 ..mu..s, the FID is drastically distorted from the exponential form while at longer tau(tau> or approx. =500 ..mu..s) an exponential FID is observed; but its transverse spin relaxation rate is smaller than that of the FID obtained after a single (1/2)..pi..x pulse and approaches this value at the limit of large tau. These findings are interpreted in terms of the theory of rapid spin diffusion. The spatial variation in the spin relaxation rate within the noncrystalline domain is inferred.
1982-02-01
International Nuclear Information System (INIS)
Pure Cu of 99.98 wt.% purity has been processed at room temperature by diverse techniques of severe plastic deformation, namely equal-channel angular pressing (ECAP), high pressure torsion (HPT) and a combination of both in order to find out the evolution on the microstructural homogeneity for each of the processes and their combination. Starting with a grain size of #approx#60 #mu#m, severe plastic deformation has been introduced to the material while maintaining the sample dimensions unchanged through the processes of ECAP and HPT. A significant decrease in grain size was observed by transmission electronic microscopy (TEM). Microtensile and microhardness tests were carried out on the deformed material in the three processing conditions. A significant improvement of the tensile strength was promoted with admissible penalization on ductility.
2008-03-25
Magnetic properties of Ab initio model of iron-based superconductors LaFeAsO
International Nuclear Information System (INIS)
By using a variational Monte Carlo method, we examine an effective low-energy model for LaFeAsO derived from an ab initio downfolding scheme. We show that quantum and many-body fluctuations near the antiferromagnetic (AF) quantum critical point largely reduce the antiferromagnetic ordered moment. Our derived model not only quantitatively reproduces the small ordered moment in LaFeAsO, but also accounts for the diversity from LaFePO, BaFe_2As_2 to FeTe. Electron correlation is found to determine the observed material dependence. We also find that LaFeAsO is subject to large orbital fluctuations, sandwiched by the AF Mott insulator and weakly correlated metals. The orbital fluctuations and Dirac-cone dispersion hold keys for the diverse magnetic properties. (author)
2011-02-01
We report electronic and magnetic structure of arsenic-doped manganese clusters from density-functional theory using generalized gradient approximation for the exchange-correlation energy. We find that arsenic stabilizes manganese clusters, though the ferromagnetic coupling between Mn atoms are found only in Mn$_2$As and Mn$_4$As clusters with magnetic moments 9 $\\mu_B$ and 17 $\\mu_B$, respectively. For all other sizes, $x=$ 3, 5-10, Mn$_x$As clusters show ferrimagnetic coupling. It is suggested that, if grown during the low temperature MBE, the giant magnetic moments due to ferromagnetic coupling in Mn$_2$As and Mn$_4$As clusters could play a role on the ferromagnetism and on the variation observed in the Curie temperature of Mn-doped III-V semiconductors.
2005-01-01
Intertemporal risk-return trade-off in foreign exchange rates
British Library Electronic Table of Contents (United Kingdom)
We investigate the intertemporal risk-return trade-off of foreign exchange (FX) rates for ten currencies quoted against the USD. For each currency, we use three risk measures simultaneously that pertain to that currency; its realized volatility, its realized skewness, and its value-at-risk. We apply monthly FX excess returns and risk measures calculated from daily observations. We find that there is a significant contemporaneous risk-return trade-off for the currencies under investigation. There is no evidence of noncontemporaneous risk-return trade-off. We pay special attention to the risk-return trade-off during the recent financial crisis.
2011-01-01
Influence of shape on ordering of granular systems in two dimensions
Energy Technology Data Exchange (ETDEWEB)
We investigate ordering properties of two-dimensional granular materials using several shapes created by welding ball bearings together. Ordered domains form much more easily in two than in three dimensions, even when configurations lack long-range order. The onset of ordered domains occurs near a packing density of 0.8, a phenomenon observed previously for disks. One of our shapes, the trapezoid, has packings that remain disordered and near the transition density even after annealing by shaking. Although random packings are unstable for disks and many other shapes in two dimensions, trapezoid packings provide an approach to studying two-dimensional randomness. We also find that the rotational symmetry of a shape is an excellent predictor of how easily it orders, and a potential guide to identifying two-dimensional shapes that remain random after annealing.
2001-06-01
Influence of Population III stars on cosmic chemical evolution
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT New observations from the Hubble Ultra Deep Field suggest that the star formation rate at Formula Not Shown drops off faster than previously thought. Using a newly determined star formation rate for the normal mode of Population II/I (PopII/I) stars, including this new constraint, we compute the Thomson scattering optical depth and find a result that is marginally consistent with Wilkinson Microwave Anisotropy Probe 5 results. We also reconsider the role of Population III (PopIII) stars in light of cosmological and stellar evolution constraints. While this input may be needed for reionization, we show that it is essential in order to account for cosmic chemical evolution in the early universe. We investigate the consequences of PopIII stars on the local metallicity distribution fu...
2009-01-01
Impacts of Imported Liquefied Natural Gas on Residential Appliance Components: Literature Review
Energy Technology Data Exchange (ETDEWEB)
An increasing share of natural gas supplies distributed to residential appliances in the U.S. may come from liquefied natural gas (LNG) imports. The imported gas will be of a higher Wobbe number than domestic gas, and there is concern that it could produce more pollutant emissions at the point of use. This report will review recently undertaken studies, some of which have observed substantial effects on various appliances when operated on different mixtures of imported LNG. While we will summarize findings of major studies, we will not try to characterize broad effects of LNG, but describe how different components of the appliance itself will be affected by imported LNG. This paper considers how the operation of each major component of the gas appliances may be impacted by a switch to LNG, and how this local impact may affect overall safety, performance and pollutant emissions.
2009-12-09
Energy Technology Data Exchange (ETDEWEB)
The electrochemical performances of orthorhombic LiMnO{sub 2} compounds are analyzed in order to find a structural and/or morphological origin to the differences of electrochemical behaviours observed in compounds with different size of crystallites and different amounts of lattice defects. Energy capacity performances of 200 Ah/kg are reached for materials with crystallites of about 10{sup 7} Angstrom{sup 3} and with about 7% of defects, while energy capacities of only 80 Ah/kg are obtained for materials with ten times bigger crystallites. (J.S.) 3 refs.
1996-12-31
British Library Electronic Table of Contents (United Kingdom)
The objective of this study was to evaluate the role of collagen membrane and Bio-Oss coverage in healing of an onlay graft to the mandible. Twelve adult sheep each received an onlay bone graft (experiment 1), bone graft+Bio-Gide (experiment 2), and bone graft+Bio-Oss/Bio-Gide (experiment 3) on the lateral surface of the mandible. The animals were euthanized at 4, 8, 12 or 16 weeks after surgery, and findings were analysed by routine microscopy and immunohistochemistry for proliferation (Ki67) and apoptotic (Caspase-3) markers. Grafts were fully incorporated in all specimens. Pronounced resorption was observed in experiment 1. Minimal loss of graft volume was seen in experiment 2 specimens without membrane displacement. A remarkable increase in the augmented region of the mandible was obse...
2008-01-01
GREEN TEA PHENOLS INTERFERENCE IN THE GLUCOSE OXIDASE/PEROXIDASE TEST
British Library Electronic Table of Contents (United Kingdom)
Abstract Green tea extract showed false-negative results in the determination of glucose via glucose oxidase (GOD) test. This investigation was undertaken to verify and find out the precise mechanism underlying this interference by determining the reaction kinetics of production and reduction of end-point chromophore. The peroxidase step of the GOD test was found to be interfered and phenols of the green tea were the interfering compounds. Green tea interfered and exerted its influence in a dual fashion. A part of the interference was observed as a result of the reduction of the finally formed chromophore, whereas the other form of interference was due to its hydrogen peroxide/free radical-scavenging activity. Reducing potential and the free radical-scavenging activity of the phenols in th...
2011-01-01
Epidemic spreading with nonlinear infectivity in weighted scale-free networks
In this paper, we investigate the epidemic spreading for SIR model in weighted scale-free networks with nonlinear infectivity, where the transmission rate in our analytical model is weighted. Concretely, we introduce the infectivity exponent $\\alpha$ and the weight exponent $\\beta$ into the analytical SIR model, then examine the combination effects of $\\alpha$ and $\\beta$ on the epidemic threshold and phase transition. We show that one can adjust the values of $\\alpha$ and $\\beta$ to rebuild the epidemic threshold to a finite value, and it is observed that the steady epidemic prevalence $R$ grows in an exponential form in the early stage, then follows hierarchical dynamics. Furthermore, we find $\\alpha$ is more sensitive than $\\beta$ in the transformation of the epidemic threshold and epidemic prevalence, which might deliver some useful information or new insights in the epidemic spreading and the correlative immunization schemes.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
This report presents the preliminary findings of the first phase of the Environmental Survey of the US Department of Energy's (DOE) National Institute for Petroleum and Energy Research (NIPER), conducted February 29 through March 4, 1988. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Team members are being provided by private contractors. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with NIPER. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at NIPER and interviews with site personnel. ...
1989-01-01
Employment, job turnover, and trade in producer services: UK firm-level evidence
British Library Electronic Table of Contents (United Kingdom)
Abstract We provide the first firm-level evidence of the impact of the trade in producer services (-offshoring-) on the labour market. Using a new data set from the UK that measures trade in services at the firm level, we find no evidence that importing intermediate services is associated with job losses or greater worker turnover. Using regression to control for observable differences between firms that import service inputs and those that do not, we show that firms that start importing intermediate services experience faster employment growth than equivalent firms that do not. This seems likely to be the result of positive demand shocks, which cause a simultaneous increase in employment, output, and use of imported service inputs.
2011-01-01
Efficiency study of different photovoltaic plant connection schemes under dynamic shading
Energy Technology Data Exchange (ETDEWEB)
An important growth in the power of the photovoltaic systems connected to a grid has recently been observed. In spite of the advances in module technology, the problems in the system design increased, especially regarding the surface of the earth they occupy. In this work we propose a complete model for plant simulation with different wiring diagrams and under dynamic shading. Results obtained from simulations showed that the configuration with the lowest performance was that of only one serial-parallel group, whereas the highest efficiency corresponded to a design of groups of modules in parallel connected then in series. In general, a higher efficiency was obtained diminishing the quantity of modules in series and increasing their number in parallel. The simulation model proposed allows exploring different alternatives of wiring modules and finding the most efficient configurations for photovoltaic plants of medium and high power. (author)
2010-06-15
Effects of antipsychotics and amphetamine on social behaviors in spontaneously hypertensive rats
British Library Electronic Table of Contents (United Kingdom)
We have recently reported that spontaneously hypertensive rats (SHRs) exhibit a deficit in contextual fear conditioning that is specifically reversed by antipsychotic and potentiated by psychostimulants and other manipulations thought to produce schizophrenia-like states in rodents. Based on these findings, we suggested that this deficit in fear conditioning could be used as an experimental model of emotional processing impairments observed in schizophrenia. This strain has also been suggested as a model by which to study attention deficit/hyperactivity disorder (ADHD). Considering that schizophrenia and ADHD are both characterized by poor social function, this study aimed to investigate possible behavioral deficits of SHRs in a social context. Furthermore, we sought to examine the effects...
2011-01-01
Distribution of domestic radon concentrations and lung cancer mortality in England and Wales
Energy Technology Data Exchange (ETDEWEB)
Using aggregate data for the counties of England and Wales, a negative association is found between mean radon concentrations in dwellings and lung cancer standardised mortality ratios, when regional smoking variations, diet variations, social class variations and population density are controlled. Cornwall and Devon have the highest mean domestic radon gas concentrations, yet the number of lung cancer deaths there was within the range to be expected from relationships not involving radon observed in the rest of the country. While high values of radon exposure appear to concentrate in particular localities, the variations in lung cancer mortality between districts in Cornwall and Devon are small. These findings do not refute the linear exposure-risk hypothesis, but the evidence suggests that relatively few, if any, radon related deaths were associated with the dwellings where radon gas concentrations exceed the recommended action level.
1988-01-01
Disorder on the string theory landscape may significantly affect dynamics of eternal inflation leading to the possibility for some vacua on the landscape to become dynamically preferable over others. We systematically study effects of a generic disorder on the landscape starting by identifying a sector with built-in disorder -- a set of de Sitter vacua corresponding to compactifications of the Type IIB string theory on Calabi-Yau manifolds with a number of warped Klebanov-Strassler throats attached randomly to the bulk part of the Calabi-Yau. Further, we derive continuum limit of the vacuum dynamics equations on the landscape. Using methods of dynamical renormalization group we determine the late time behavior of the probability distribution for an observer to measure a given value of the cosmological constant. We find the diffusion of the probability distribution to significantly slow down in sectors of the landscape where the number of ...
2008-01-01
Covariance of quantum general relativity from Ashtekar variables
In this paper we examine the relationship between covariance and unitarity for quantum gravity in Ashtekar variables. A usual description would discard half of the original Lorentz group, in exchange for the resulting simplifications of general relativity. We start by quantizing a trivial SL(2,C) gauge theory resulting in a nonunitary covariant theory. By the addition of a total time derivative we transform this into a unitary theory of the Ashtekar description of gravity with complete accountability of the degrees of freedom. We find that covariance on the spacetime level bears a direct relationship to covariance on the level ofthe quantum fields themselves. This procedure can in principle be applied to any totally constrained system, and bears a resemblance to the Gupta--Bleuler method. Finally, we make some observation regarding the loop representation of the SL(2,C) connection.
2008-01-01
Cosmological parameter estimation using Particle Swarm Optimization (PSO)
Obtaining the set of cosmological parameters consistent with observational data is an important exercise in current cosmological research. It involves finding the global maximum of the likelihood function in the multi-dimensional parameter space. Currently sampling based methods, which are in general stochastic in nature, like Markov-Chain Monte Carlo(MCMC), are being commonly used for parameter estimation. The beauty of stochastic methods is that the computational cost grows, at the most, linearly in place of exponentially (as in grid based approaches) with the dimensionality of the search space. MCMC methods sample the full joint probability distribution (posterior) from which one and two dimensional probability distributions, best fit (average) values of parameters and then error bars can be computed. In the present work we demonstrate the application of another stochastic method, named Particle Swarm Optimization (PSO), that is widely used ...
2011-01-01
Correlation of MRI and histomorphological findings in bone marrow oedema syndrome of the hip
Energy Technology Data Exchange (ETDEWEB)
In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)
1993-10-01
Constraining Parity Violation in Gravity with Measurements of Neutron-Star Moments of Inertia
Neutron stars are sensitive laboratories for testing general relativity, especially when considering deviations where velocities are relativistic and gravitational fields are strong. One such deviation is described by dynamical, Chern-Simons modified gravity, where the Einstein-Hilbert action is modified through the addition of the gravitational parity-violating Pontryagin density coupled to a field. This four-dimensional effective theory arises naturally both in perturbative and non-perturbative string theory, loop quantum gravity, and generic effective field theory expansions. We calculate here Chern-Simons modifications to the properties and gravitational fields of slowly spinning neutron stars. We find that the Chern-Simons correction affects only the gravitomagnetic sector of the metric to leading order, thus introducing modifications to the moment of inertia but not to the mass-radius relation. We show that an observational determination ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The proton and deuteron spectra following resonant multiphoton ionization of H{sub 2} and HD at 193 nm through the {ital E},{ital F} state have been studied at power densities of 10{sup 10} W/cm{sup 2}. Our results show that the intermediate state induces competition between 3(2+1)-photon ionization, dissociation, and dissociative ionization channels. We find that the competition depends on the specific vibrational and rotational levels excited in the intermediate state. At the same time, the mere presence of this bound intermediate state renders these three-photon fragmentation channels so efficient that higher-order fragmentation processes, such as Coulomb explosions requiring many more photons, are not observed.
1991-04-01
Bi-directional causality in California's electricity and natural-gas markets
International Nuclear Information System (INIS)
The Granger instantaneous-causality test is applied to explore the potential causal relationships between wholesale electricity and natural-gas prices in California. The test shows these relationships to be bi-directional, and reveals California's electricity and natural-gas markets to be as inextricably intertwined as casual observation and theoretical considerations would suggest they ought to be. This meshing of markets exacerbated the effects of California's natural-gas crisis on the contemporaneous electricity crisis, while concurrently the electricity crisis may have contributed to the dysfunction in the national-gas market and helped to precipitate the natural-gas crisis. The finding supports an integrated approach, as opposed to a piecemeal approach, for formulating energy policy recommendations, not just in California but in the world at large. (author)
2006-10-01
Bi-directional causality in California's electricity and natural-gas markets
International Nuclear Information System (INIS)
The Granger instantaneous-causality test is applied to explore the potential causal relationships between wholesale electricity and natural-gas prices in California. The test shows these relationships to be bi-directional, and reveals California's electricity and natural-gas markets to be as inextricably intertwined as casual observation and theoretical considerations would suggest they ought to be. This meshing of markets exacerbated the effects of California's natural-gas crisis on the contemporaneous electricity crisis, while concurrently the electricity crisis may have contributed to the dysfunction in the national-gas market and helped to precipitate the natural-gas crisis. The finding supports an integrated approach, as opposed to a piecemeal approach, for formulating energy policy recommendations, not just in California but in the world at large.
2006-10-01
Associated central exclusive production of charged Higgs bosons
We propose central exclusive production of a charged Higgs boson in association with a W boson as a possible signature of certain types of extended Higgs sectors. We calculate the cross section and find that the rate at the LHC could be large enough to allow observation in some models with two Higgs doublets, where the charged Higgs and at least one of the neutral scalars can be light enough. We use the two-Higgs doublet model as a prototype and consider two distinct regions of parameter space, but we also briefly discuss the prospects for the next-to-minimal supersymmetric standard model, where the charged Higgs may very well be quite light.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
In this study we investigated cultural, familial, and individual beliefs that influenced international students? perceptions of therapy and help-seeking behaviors. Included were changes in perception or behavior before and after the students came to the US, and factors that influenced help-seeking behaviors. Six international students from East Asian countries where English is a foreign language, including Taiwan, Mainland China, Japan, and South Korea, were interviewed. We used semi-structured interviews and participant observations for collecting data. The findings indicated changes after students came to the US. Further discussions focus on encouraging and discouraging factors relative to seeing therapists, and culturally sensitive interventions for family therapy clinicians.
2011-01-01
Analysis of recent {eta} photoproduction data
Energy Technology Data Exchange (ETDEWEB)
Recent data on {eta} -meson photoproduction off a proton target in the energy range 2 {<=}{radical}(s){<=} 3 GeV are analyzed with regard to their overall consistency. Results from the ELSA and CLAS measurements are compared with predictions of a Regge model whose reaction amplitude was fixed via a global fit to pre-2000 measurements of differential cross sections and polarization observables for {gamma}p{yields}{eta}p at higher energies. We find that all recent experimental results on differential cross sections for {eta} -meson photoproduction are in good agreement with each other, except for the CLAS data from 2009. However, the latter can be made consistent with the other data at the expense of introducing an energy-dependent renormalization factor. We point out that there are indications in the data for a possible excitation of baryon resonances with masses around 2.1 and 2.4GeV. (orig.)
2010-12-15
An assessment of health impacts of electrical power transmission lines
International Nuclear Information System (INIS)
The types of investigations undertaken to test for possible biological effects of extremely low frequency electric fields have been numerous. However, neither animal and plant experimentation nor clinical studies nor experience with operating extremely high voltage transmission lines have to date provided convincing evidence of a harmful effect from exposure to electric fields associated with transmission lines in spite of numerous attempts to find such effects. Analysis of internal fields and currents supports these observations as the levels appear to be too low to affect mammalian cells. Thus, while one can never prove the negative (i.e. that there is no effect), the overwhelming body of evidence indicates that the electric fields associated with high-voltage lines have no deleterious biological effects. (author).
1981-06-26
A unified framework for biological evolution and stochastic quantization
We investigate the profound relation between the equations of biological evolution and quantum mechanics by writing a biologically inspired equation for the stochastic dynamics of an ensemble of particles. Interesting behavior is observed which is related to a new type of stochastic quantization. We find that the probability distribution of the ensemble of particles can be decomposed into eigenfunctions associated to a discrete spectrum of eigenvalues. In absence of interactions between the particles, the out-of-equilibrium dynamics asymptotically relaxes towards the fundamental state. This phenomenon can be related with the Fisher theorem in biology. On the contrary, in presence of scattering processes the evolution reaches a steady state in which the distribution of the ensemble of particles is characterized by a Bose-Einstein statistics. In order to show a concrete example of this stochastic quantization we have solved explicitly the case in ...
2010-01-01
A study of the Teachers` Academy for Mathematics and Science
Energy Technology Data Exchange (ETDEWEB)
The Teachers` Academy for Mathematics and Science in Chicago (TAMS) is a freestanding institution founded in 1989 by scientists and a variety of other stakeholders, to advance the systemic reform of mathematics and science education in Chicago`s public schools. It focuses on the ``re-tooling`` of its elementary level teachers. The TAMS program, which has been funded in part by the DOE, contributes to strategic goals two through five of the Office of University and Science Education (OUSE). This evaluation of TAMS by the National Center for Improving Science Education is primarily a qualitative study that summarizes the history and current status of the organization and its programs. Data was obtained through extensive interviews, observations, and document review, using a framework of templates to guide data collection and analyses. The findings are organized around a series of lessons learned from the first three years of TAMS and conclusions ...
1994-09-15
A study of methyl formate in astrochemical environments
Several complex organic molecules are routinely detected in high abundances towards hot cores and hot corinos. For many of them, their paths of formation in space are uncertain, as gas phase reactions alone seem to be insufficient. In this paper, we investigate a possible solid-phase route of formation for methyl formate (HCOOCH3). We use a chemical model updated with recent results from an experiment where simulated grain surfaces were irradiated with 200 keV protons at 16 K, to simulate the effects of cosmic ray irradiation on grain surfaces. We find that this model may be sufficient to reproduce the observed methyl formate in dark clouds, but not that found in hot cores and corinos.
2011-01-01
A new method of determining the inclination angle in interacting binaries
We describe a method of determining the system parameters in non-eclipsing interacting binaries. We find that the extent to which an observer sees the shape of the Roche-lobe of the secondary star governs the amount of distortion of the absorption line profiles. The width and degree of asymmetry of the phase-resolved absorption line profiles show a characteristic shape, which depends primarily on the binary inclination and gravity darkening exponent. We show that, in principle, by obtaining high spectral and time resolution spectra of quiescent cataclysmic variables or low mass X-ray binaries in which the mass-losing star is visible, fitting the shape of absorption line profiles will allow one to determine not only the mass function of the binary, but also the binary inclination and hence the mass of the binary components.
1998-01-01
This contribution deals with identification of fractional-order dynamical systems. System identification, which refers to estimation of process parameters, is a necessity in control theory. Real processes are usually of fractional order as opposed to the ideal integral order models. A simple and elegant scheme of estimating the parameters for such a fractional order process is proposed. This method employs fractional calculus theory to find equations relating the parameters that are to be estimated, and then estimates the process parameters after solving the simultaneous equations. The said simultaneous equations are generated and updated using particle swarm optimization (PSO) technique, the fitness function being the sum of squared deviations from the actual set of observations. The data used for the calculations are intentionally corrupted to simulate real-life conditions. Results show that the proposed scheme offers a very high degree of ...
2008-01-01
"2"2"2Rn as indicator of atmospheric turbulence: measurements at Lake Maggiore and on the pre-Alps
International Nuclear Information System (INIS)
Radon concentration measurements in atmosphere were taken in years from 1997 to 1999 in Milan and at pre-alpine sites located north of Lombardy. In this paper the results of measuring campaigns and a comparison of radon levels observed in the hilly area north of the town and on the pre-Alps are reported. The general criteria of the measurements and the interpretative models of radon concentration are presented. The Lake Maggiore area shows evidence of a great nocturnal stability and frequent formation of Nocturnal Stable Layer. The peculiar findings in the high altitude stations confirm the use of radon as an indicator of atmospheric dispersion of pollutants in an area with complex orography. The afternoon minimum values are concordant for the different stations: this implies a remixing in afternoon hours over the whole area investigated.
Increased renal corticomedullary FDG activity in a patient of NHL-malignant or benign?
International Nuclear Information System (INIS)
Authors describe diagnostic dilemma of differentiating pyelonephritis with lymphomatous involvement of kidney in a known case of lymphoma. FDG uptake pattern was non-discriminatory and pyelonephritis diagnosed retrospectively on follow up study. Authors emphasize the importance of recognition of features and subtle clues of infection evident on CT component of PET-CT. (author)
Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle
Energy Technology Data Exchange (ETDEWEB)
The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.
1988-10-13
International Nuclear Information System (INIS)
The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% ...
1991-01-01
CT imaging of a primary malignant mixed mullerian tumor arising from the peritoneum
British Library Electronic Table of Contents (United Kingdom)
Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computed tomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, ...
2000-10-01
Abdominal masses in the pediatric age. Characterization by CT guided fine needle aspiration biopsy
International Nuclear Information System (INIS)
CT-guided fine needle aspiration biopsy (FNAB) is known to improve diagnosis of expansive abdominal lesions, especially relative to more invasive procedure like explorative laparotomy. FNAB in not commonly use in pediatric patients because of their poor collaboration and of associated risks. The authors investigated the feasibility of FNAB in the pediatric age.
1999-04-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt ...
1996-11-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in ...
2000-05-01
Value of ultrasonography, Ct and MR imaging in the diagnosis of primary hyperparathyroidism
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate the significance of preoperative localization of abnormal parathyroid glands to the surgical outcome in patients with primary hyperparathyroidism. Material and Methods: Thirty-nine patients with primary hyperparathyroidism were studied preoperatively with US (39 patients), CT (30 patients) and MR imaging (18 patients). The overall diagnostic accuracy for US was 87%, CT 66% and MR 94%. In patients with a single parathyroid adenoma US was the most cost-effective localization technique with a detection rate of 96%. CT had a lower detection rate (78%) but was of particular value for fairly large ectopic adenomas in the root of the neck. MR imaging was a good confirmatory test (93%). In patients with multiple gland disease (primary hyperplasia and multiple adenomas), no single localization study alone was sufficient. Combination of all 3 studies, however, alerted the physician to the presence of disease in ...
1996-09-01
Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity
International Nuclear Information System (INIS)
Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt ...
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work is to describe the radiological appearance of overlooked malignant pulmonary lesions at CT and to analyze the reasons of misdiagnosis. Ten patient with pulmonary lesion (PML) overlooked at forst CT examination were selected among patients with lung cancer. Endobronchial location of the tumors and their small size were the most frequent causes of misdiagnosis of PML at chest CT in the series. However, a systematic evaluation of CT scans can reduce the percentage of missed lesions. [Italian] Scopo del presente lavoro e' di descrivere le caratteristiche radiologiche delle lesioni polmonari maligne non identificate con la Tomografia Computerizzata (TC) e definire le possibili cause di errore. Sono stati esaminato 10 pazienti con tumore polmonare. Le sedi endobronchiale e centrale nonche' le piccole dimensioni delle lesioni polmonari maligne rappresentano le cause ...
1999-06-01
International Nuclear Information System (INIS)
We used computerized tomography (CT) in the study of eight patients with macronodular splenic tuberculosis prior to the microbiological diagnosis. These patients underwent additional CT controls during and after tuberculostatic therapy. All the patients studed presented the acquired immunodeficiency syndrome (AIDS). Splenomegaly and numerosous round, hypodense lesions that showed no contrast uptake were found in all the subjects. Only three patients presented evidence of tuberculosis in plain radiography and/or chest X-ray. Two patients presented abdominal lymph nodes. None of them showed evidence of hepatic lesions or ascites. follow-up CT scans revealed a progressive reduction of the lesions, which eventually disappeared completely, and splenomegaly was considerably reduced. Anthough it is uncommon, we should suspect splenic involvement in tuberculosis if the clinical and radiological contexts are appropriate. ...
Is energy imparted a good measure of the radiation risk associated with CT examinations
International Nuclear Information System (INIS)
The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the ...
Computed tomography of the orbit
Energy Technology Data Exchange (ETDEWEB)
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital ...
1981-01-01
International Nuclear Information System (INIS)
The contribution of US, CT and MR imaging was investigated in 25 cirrhotic patients with hepatocellular carcinoma. The following parameters were considered: lesion detection, site and size of the lesion, daughter nodules, location and/or infiltration of intrahepatic vessels, patency of portal vein and collateral vessels, signs of chronic liver disease, steatosis, ascitis, and lymphadenopathy. The results confirm the value of US, which also allowed lesion biopsy in all cases. CT was as accurate as US in detecting the lesion and even superior in demonstranting daughter nodules. MR imaging, with conventional SE and IR sequences, was inferior since it missed 3 lesions due to motion artifacts; more over, a smaller number of daughter nodules was seen than with CT. The authors conclude that, at present, MR imaging cannot replace US and CT; the latter, if combined with artheriography, using either hidrosoluble ...
1991-01-01
Atelectasis on pediatric chest CT: comparison of sedation techniques
International Nuclear Information System (INIS)
Background. A change in practice at our institution resulted in increased use of anesthesia for CT scan of the chest in children who required sedation. Objective. To determine whether there is a difference in the frequency or severity of pulmonary atelectasis on CT scan in children sedated by anesthesiologists compared with children sedated by radiologists using intravenous pentobarbital. Materials and methods. Retrospective blinded review of 60 CT scans of the chest performed in 41 children. Forty-one studies in children sedated by radiologists (median age 29 months) were compared with 19 studies in children sedated by anesthesiologists (median age 25 months). Results. Atelectasis sufficient to obscure pulmonary metastases was shown in 5 of 41 (12 %) radiology sedations and 13 of 19 (68 %) anesthesiology sedations (P < 0.01). Higher grades of atelectasis were recorded in children under anesthesia (P < 0.01). ...
1999-07-01
The quantum N-body problem with a minimal length
The quantum $N$-body problem is studied in the context of nonrelativistic quantum mechanics with a one-dimensional deformed Heisenberg algebra of the form $[\\hat x,\\hat p]=i(1+\\beta \\hat p^2)$, leading to the existence of a minimal observable length $\\sqrt\\beta$. For a generic pairwise interaction potential, analytical formulas are obtained that allow to estimate the ground-state energy of the $N$-body system by finding the ground-state energy of a corresponding two-body problem. It is first shown that, in the harmonic oscillator case, the $\\beta$-dependent term grows faster with $N$ than the $\\beta$-independent one. Then, it is argued that such a behavior should be observed also with generic potentials and for $D$-dimensional systems. In consequence, quantum $N$-body bound states might be interesting places to look at nontrivial manifestations of a minimal length since, the more particles are present, the more the ...
2010-01-01
The entomopathogenic nematode (EPN), Steinernema feltiae, is a commonly occurring nematode in the soil in Ireland. Consequently, we have conducted investigations as to the utility of this species as a candidate organism for the detection of chromium in Irish soils. These experiments have demonstrated that S. feltiae can survive and reproduce in the presence of high concentrations of chromium VI. It was observed that concentrations as high as 1000 ppm have little effect on the ability of this organism to produce large numbers of progeny. Nematodes were not observed to reproduce above 1800 ppm. However, an increase in development times for the nematode in vivo was noted at concentrations of 400 ppm upwards. This paper also illustrates the effects upon the beta-tubulin genes within nematode populations exposed to chromium VI in vivo. DNA sequencing has shown that elevated levels of variations occur among the population treatments, although these ...
2008-07-18
Wolf-Rayet stars (WRs) are evolved massive stars, and the relative number of WC-type and WN-type WRs should vary with metallicity, providing a sensitive test of stellar evolutionary theory. The observed WC/WN ratio is much higher than that predicted by theory in some galaxies but this could be due to observational incompleteness for WN-types, which have weaker lines. Previous studies of M33's WR content show a galactocentric gradient in the relative numbers of WCs and WNs, but only small regions have been surveyed with sufficient sensitivity to detect all of the WNs. Here we present a sensitive survey for WRs covering all of M33, finding 55 new WRs, mostly of WN type. Our spectroscopy also improves the spectral types of many previously known WRs, establishing in one case that the star is actually a background quasar. The total number of spectroscopically confirmed WRs in M33 is 206, a number we argue is complete to ...
2011-01-01
Sunyaev-Zeldovich profiles for clusters and groups of galaxies
The Sunyaev-Zeldovich (SZ) effect gives a measure of the thermal energy and electron pressure in groups and clusters of galaxies. In the near future SZ surveys will map hundreds of systems, shedding light on the pressure distribution in the systems. The thermal energy is related to the total mass of a system of galaxies, but it is only a projection that is observed through the SZ effect. A model for the 3D distribution of pressure is needed to link the SZ signal to the total mass of the system. In this work we construct an empirical model for the 2D and 3D SZ profile, and compare it to a set of realistic high resolution SPH simulations of galaxy clusters and groups, and to a stacked SZ profile for massive clusters derived from WMAP data. Furthermore, we combine observed temperature profiles with dark matter potentials to yield an additional constraint, under the assumption of hydrostatic equilibrium. We find a very tight ...
2007-01-01
We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral analysis is an important step to ...
2010-01-01
Spatial Damping of Propagating Kink Waves Due to Resonant Absorption: Effect of Background Flow
Observations show the ubiquitous presence of propagating magnetohydrodynamic (MHD) kink waves in the solar atmosphere. Waves and flows are often observed simultaneously. Due to plasma inhomogeneity in the perpendicular direction to the magnetic field, kink waves are spatially damped by resonant absorption. The presence of flow may affect the wave spatial damping. Here, we investigate the effect of longitudinal background flow on the propagation and spatial damping of resonant kink waves in transversely nonuniform magnetic flux tubes. We combine approximate analytical theory with numerical investigation. The analytical theory uses the thin tube (TT) and thin boundary (TB) approximations to obtain expressions for the wavelength and the damping length. Numerically, we verify the previously obtained analytical expressions by means of the full solution of the resistive MHD eigenvalue problem beyond the TT and TB approximations. We ...
2011-01-01
We study the Sunyaev-Zel'dovich (SZ) effect potentially generated by relativistic electrons injected from dark matter (DM) annihilation or decay in the Galaxy, and check whether it could be observed by Planck or ALMA, or even imprint the current CMB data as e.g. the specific fluctuation excess claimed from an recent re-analysis of the WMAP-5 data. We focus on high-latitude regions to avoid contamination of the Galactic astrophysical electron foreground, and consider the annihilation or decay coming from the smooth DM halo as well as from subhalos, further extending our analysis to a generic modeling of spikes arising around intermediate-mass-black-holes (IMBHs). We show that all these dark Galactic components are unlikely to produce any observable SZ effect. For a self-annihilating DM particle of 10 GeV with canonical properties, the largest optical depth we find is $\\tau_e \\lesssim 10^{-7}$ for massive isolated subhalos ...
2010-01-01
Radiation induced micrencephaly in guinea pigs
International Nuclear Information System (INIS)
A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays at doses of 75-mGy during this late ...
2006-04-20
Quark and Gluon Tagging at the LHC
Being able to distinguish light-quark jets from gluon jets on an event-by-event basis could significantly enhance the reach for many new physics searches at the Large Hadron Collider. Through an exhaustive search of existing and novel jet substructure observables, we find that a multivariate approach can filter out over 95% of the gluon jets while keeping more than half of the light-quark jets. Moreover, a combination of two simple variables, the charge track multiplicity and the pT-weighted linear radial moment (girth), can achieve similar results. While this pair appears very promising, our study is only Monte Carlo based, and other discriminants may work better with real data in a realistic experimental environment. To that end, we explore many other observables constructed using different jet sizes and parameters, and highlight those that deserve further theoretical and experimental scrutiny. Additional information, ...
2011-01-01
Pulsars as the Sources of High Energy Cosmic Ray Positrons
Recent preliminary results from the PAMELA satellite indicate the presence of a large flux of positrons (relative to electrons) in the cosmic ray spectrum between approximately 10 and 50 GeV. As annihilating dark matter particles in many models are predicted to contribute to the cosmic ray positron spectrum in this energy range, a great deal of interest has resulted from this observation. Here, we consider pulsars (rapidly spinning, magnetized neutron stars) as an alternative source of this signal. After calculating the contribution to the cosmic ray positron and electron spectra from pulsars, we find that the spectrum observed by PAMELA could plausibly originate from such sources. In particular, a significant contribution is expected from the sum of all mature pulsars throughout the Milky Way, as well as from the most nearby mature pulsars (such as Geminga and B0656+14). The signal from nearby pulsars is expected to ...
2009-01-01
N-body Models of Extended Clusters
We use direct N-body simulations to investigate the evolution of star clusters with large size-scales with the particular goal of understanding the so-called extended clusters observed in various Local Group galaxies, including M31 and NGC6822. The N-body models incorporate a stellar mass function, stellar evolution and the tidal field of a host galaxy. We find that extended clusters can arise naturally within a weak tidal field provided that the tidal radius is filled at the start of the evolution. Differences in the initial tidal filling-factor can produce marked differences in the subsequent evolution of clusters and the size-scales that would be observed. These differences are more marked than any produced by internal evolution processes linked to the properties of cluster binary stars or the action of an intermediate-mass black hole, based on models performed in this work and previous work to date. Models evolved in a ...
2010-01-01
Forecasting neutrino masses from combining KATRIN and the CMB: Frequentist and Bayesian analyses
We present a showcase for deriving bounds on the neutrino masses from laboratory experiments and cosmological observations. We compare the frequentist and Bayesian bounds on the effective electron neutrino mass m_beta which the KATRIN neutrino mass experiment is expected to obtain, using both an analytical likelihood function and Monte Carlo simulations of KATRIN. Assuming a uniform prior in m_beta, we find that a null result yields an upper bound of about 0.17 eV at 90% confidence in the Bayesian analysis, to be compared with the frequentist KATRIN reference value of 0.20 eV. This is a significant difference when judged relative to the systematic and statistical uncertainties of the experiment. On the other hand, an input m_beta=0.35 eV, which is the KATRIN 5sigma detection threshold, would be detected at virtually the same level. Finally, we combine the simulated KATRIN results with cosmological data in the form of present (post-WMAP) and ...
2007-01-01
Early stages during plasma nitriding of pure iron
Energy Technology Data Exchange (ETDEWEB)
The sequence of nitride formation during the early stages of plasma nitriding of pure iron was studied by optical microscopy, SEM, TEM and x-ray diffraction. Plasma nitriding at {approximately}490 C in a 25 vol.%H{sub 2} + 75 vol.%N{sub 2} mixture starts with the formation of {gamma}{prime}-Fe{sub 4}N after 40s. Once {gamma}{prime} nucleates, it mainly spreads laterally due to diffusion shortcuts in the discontinuous surface nitride layer. Before {gamma}{prime} is continuous on the surface, {epsilon} nucleates on top of it shortly after 40S. Epsilon is then observed to grow, both inwardly and laterally along with {gamma}{prime}. A compact {gamma}{prime}/{epsilon} bilayer forms on the surface at around 100s. The kinetics of nucleation, growth and compactation of the nitrides observed in the present work was significantly more rapid than in any of the nitriding process reported in the literature, including plasma nitriding. The acceleration of ...
1995-12-31
Detailed comparison of the structures and kinematics of simulated and observed barred galaxies
We examine the observable properties of simulated barred galaxies including radial mass profiles, edge-on structure and kinematics, bar lengths and pattern speed evolution for detailed comparison to real systems. We have run several simulations in which bars are created through inherent instabilities in self-consistent simulations of a realistic disc+halo galaxy model with a disc-dominated, flat rotation curve. These simulations were run at high (N=20M particles) and low (N=500K) resolution to test numerical convergence. We determine the pattern speeds in simulations directly from the phase angle of the bar versus time and the Tremaine-Weinberg method. Fundamental dynamics do not change between the high and low resolution, suggesting that convergence has been reached in this case. We find the higher resolution is needed to simulate structural and kinematic properties accurately. The edge-on view of the higher-resolution system clearly shows the ...
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft revascularization. The circulation in rib grafts was accurately reflected in technetium 99 bone scans, as was the patency of the anastomoses of microvascularized ...
1984-11-01
Changes in Sea-Level Pressure over South Korea Associated with High-Speed Solar Wind Events
We explore a possibility that the daily sea-level pressure (SLP) over South Korea responds to the high-speed solar wind event. This is of interest in two aspects: First, if there is a statistical association this can be another piece of evidence showing that various meteorological observables indeed respond to variations in the interplanetary environment. Second, this can be a very crucial observational constraint since most models proposed so far are expected to preferentially work in higher latitude regions than the low latitude region studied here. We have examined daily solar wind speed ${\\rm V}$, daily SLP difference ${\\rm \\Delta SLP}$, and daily ${\\rm \\log(BV^{2})}$ using the superposed epoch analysis in which the key date is set such that the daily solar wind speed exceeds 800 ${\\rm kms^{-1}}$. We find that the daily ${\\rm \\Delta SLP}$ averaged out of 12 events reaches its peak at day +1 and gradually ...
2011-01-01
Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources
We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described by a single power law model with Galactic absorption. However, in six quasars we find ...
2003-01-01
A Statistical Treatment of the Gamma-Ray Burst "No Host Galaxy" Problem; 1, Methodology
If gamma-ray bursts originate in galaxies at cosmological distances, the host galaxy should be detected if a burst error box is searched deep enough; are the host galaxies present? We present and implement a statistical methodology which evaluates whether the observed galaxy detections in a burst's error box are consistent with the presence of the host galaxy, or whether all the detections can be attributed to unrelated background galaxies. This methodology requires the model-dependent distribution of host galaxy fluxes. While our methodology was derived for galaxies in burst error boxes, it can be applied to other candidate host objects (e.g., active galaxies) and to other types of error boxes. As examples, we apply this methodology to two published studies of burst error boxes. We find that the nine error boxes observed by Larson and McLean (1997) are too large to discriminate between the presence or absence of host ...
1997-01-01
Primary malignant lymphoma of the brain; Primaere maligne Lymphome des Gehirns
Energy Technology Data Exchange (ETDEWEB)
Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar ...
1997-01-01
Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging
Energy Technology Data Exchange (ETDEWEB)
We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was ...
2008-07-01
THE EVOLUTION OF THE STAR FORMATION RATE OF GALAXIES AT 0.0 #<=# z #<=# 1.2
International Nuclear Information System (INIS)
We present the 24 #mu#m rest-frame luminosity function (LF) of star-forming galaxies in the redshift range 0.0 #<=# z #<=# 0.6 constructed from 4047 spectroscopic redshifts from the AGN and Galaxy Evolution Survey of 24 #mu#m selected sources in the Booetes field of the NOAO Deep Wide-Field Survey. This sample provides the best available combination of large area (9 deg"2), depth, and statistically complete spectroscopic observations, allowing us to probe the evolution of the 24 #mu#m LF of galaxies at low and intermediate redshifts while minimizing the effects of cosmic variance. In order to use the observed 24 #mu#m luminosity as a tracer for star formation, active galactic nuclei (AGNs) that could contribute significantly at 24 #mu#m are identified and excluded from our star-forming galaxy sample based on their mid-IR spectral energy distributions or the detection of X-ray emission. Optical emission line diagnostics are considered for ...
2010-08-01
Transarterial Chemoembolization (TACE) for Inoperable Intrahepatic Cholangiocarcinoma
International Nuclear Information System (INIS)
The aim of this retrospective study was to determine the safety and efficacy of chemoembolization (TACE) as palliative treatment for patients with unresectable intrahepatic cholangiocarcinoma (CCA) and to compare the results with those in the literature. Fifteen patients with histology-proven CCA (5 men, 10 women) had received palliative treatment with TACE over a 6-year period. The treatment protocol comprised repeated TACE at a minimum of 8-week intervals. TACE was performed with a mixture of 10 ml Lipiodol and 10 mg mitomycin C injected into the tumor-supplying vessels. Follow-up investigations after 8-10 weeks comprised contrast-enhanced multislice spiral CT and laboratory control. Statistical evaluation included survival analysis using the Kaplan-Meier method. During the investigation period 58 TACEs (3.9 #+-# 3.8; 1-15) were performed in 15 patients. Mean tumor size was 10.8 #+-# 4.6 cm (range, 2.0-18.0 cm). Unifocal tumor disease was diagnosed in eight ...
2007-11-01
SGTR Project: Separate Effect Studies for Vertical Steam Generators
Energy Technology Data Exchange (ETDEWEB)
The SGTR project has been carried out within the fifth EURATOM Framework Programme (Contract No FIKS-CT-1999-0007). Its main objective was to provide an experimental database and to develop and/or verify models to support definition of accident management measures in the hypothetical case of a Steam Generator tube Rupture (SGTR) sequence. The project addressed both vertical and horizontal steam generator designs. This report summarises the main results obtained in the intermediate scale experimentation that addressed Western type steam generators. The specific goal of this test programme was to investigate aerosol retention in the break stage of the secondary side of a water-empty steam generator. The test matrix consisted of 12 tests that explored the influence of variables such as break type and orientation and inlet gas flow rate. This work was performed in the PECA facility of the Laboratory for Analysis of Safety Systems (LASS). Aerosol retention at the break ...
2003-07-01
Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation
Energy Technology Data Exchange (ETDEWEB)
The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in ...
2003-04-01
Characteristics of meningioma scintigraphy with multiple brain imaging agents
International Nuclear Information System (INIS)
Purpose: To clarify the characteristics of meningioma scintigraphy with multiple brain imaging agents and to evaluate their roles in diagnosis of meningiomas. Methods: Blood flow, "9"9"mTc-ECD, "9"9"mTc-DTPA, and/or "9"9"mTc-MIBI brain imagings were performed in 21 patients with meningiomas (3 malignant, 18 benign) proved by surgery and pathology. CT/MRI examinations were also made within one month. Characteristics of meningioma images were analyzed and uptake ratios were calculated. Results: In 16 of 20 patients, increased radioactivity during the arterial phase in the blood flow image was seen. Concave round or oval defects with smooth contour in the cerebral cortex were observed in 17 of 19 patients with "9"9"mTc-ECD, depression of frontoparietal cortex was found in one case and no abnormality in the other. A homogeneous accumulation of radioactivity in area corresponding to the defect in "9"9"mTc-ECD image was found in 17/17 patients with ...
1998-08-01
THE EVOLUTION OF LYMAN LIMIT ABSORPTION SYSTEMS TO REDSHIFT SIX
International Nuclear Information System (INIS)
We have measured the redshift evolution of the density of Lyman limit systems (LLSs) in the intergalactic medium over the redshift range 0 < z < 6. We have used two new quasar samples to (1) improve coverage at z #approx# 1, with GALEX grism spectrograph observations of 50 quasars with 0.8 < z_e_m < 1.3, and (2) extend coverage to z #approx# 6, with Keck ESI spectra of 25 quasars with 4.17 < z_e_m < 5.99. Using these samples together with published data, we find that the number density of LLS per unit redshift, n(z), can be well fit by a simple evolution of the form n(z) = n_3_._5[(1 + z)/4.5]"#gamma# with n_3_._5 = 2.80 #+-# 0.33 and #gamma# = 1.94"+"0"."3"6_-_0_._3_2 for the entire range 0 < z < 6. We have also reanalyzed the evolution of damped Ly#alpha# systems (DLAs) in the redshift range 4 < z < 5 using our high-redshift quasar sample. We find a total of 17 DLAs and sub-DLAs, which we ...
2010-10-01
Experimental chemo- and radio-therapy on human cholangiocarcinoma transplanted to nude mice
International Nuclear Information System (INIS)
A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse cytophotometry, ...
Primary Ewing's sarcoma of the vertebral column
International Nuclear Information System (INIS)
To determine the demographics, imaging findings, clinical symptoms, and prognosis of primary vertebral Ewing's sarcoma (PVES). A retrospective review of medical records and radiological studies of patients diagnosed with PVES from 1936 through 2001 in our institution and Department of Pathology consultation files was undertaken. Metastatic and soft tissue Ewing's sarcoma cases were excluded. From a total of 1,277 cases of Ewing's sarcoma, 125 (9.8%) had a primary vertebral origin. There were 48 females and 76 males. Patient ages ranged from 4 to 54 (mean 19.3, standard deviation 10.7, median 16) years. Vertebral column distribution was four cervical (3.2%), 13 thoracic (10.5%), 31 lumbar (25%), and 67 sacrum (53.2%). More than one vertebral segment was involved in ten cases (8%). Satisfactory imaging studies were available in 51 patients: 49 radiographs, 27 computerized tomography (CT), and 23 magnetic resonance imaging (MRI) studies. The ...
2004-09-01
Energy Technology Data Exchange (ETDEWEB)
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent ...
2003-03-01
PROBING THE ORIGINS OF THE C IV AND Fe K? BALDWIN EFFECTS
International Nuclear Information System (INIS)
We use UV/optical and X-ray observations of 272 radio-quiet Type 1 active galactic nuclei and quasars to investigate the C IV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths (EWs), continuum monochromatic luminosities, and ?ox, which characterizes the relative X-ray to UV brightness. The EW of the C IV ?1549 emission line is correlated with both ?ox and luminosity. We find that by regressing l?(2500 A) with EW(C IV) and ?ox, we can obtain tighter correlations than by regressing l?(2500 A) with only EW(C IV). Both correlation and regression analyses imply that l?(2500 A) is not the only factor controlling the changes of EW(C IV); ?ox (or, equivalently, the soft X-ray emission) plays a ...
2009-09-01
Observation of B0(s) - anti-B0(s) Oscillations
Energy Technology Data Exchange (ETDEWEB)
The authors report the observation of B{sub s}{sup 0}-{bar B}{sub s}{sup 0} oscillations from a time-dependent measurement of the B{sub s}{sup 0}-{bar B}{sub s}{sup 0} oscillation frequency {Delta}m{sub s}. Using a data sample of 1 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV collected with the CDF II detector at the Fermilab Tevatron, they find signals of 5600 fully reconstructed hadronic B{sub s} decays, 3100 partially reconstructed hadronic B{sub s} decays, and 61,500 partially reconstructed semileptonic B{sub s} decays. They measure the probability as a function of proper decay time that the B{sub s} decays with the same, or opposite, flavor as the flavor at production, and they find a signal for B{sub s}{sup 0}-{bar B}{sub s}{sup 0} oscillations. The probability that random fluctuations could produce a comparable signal is 8 x 10{sup -8}, which exceeds 5{sigma} significance. They measure {Delta}m{sub s} = ...
2006-09-01
Luminous HC3N line emission in NGC4418 - buried AGN or nascent starburst?
IRAM 30m observations reveal that the deeply obscured IR-luminous galaxy NGC4418 has a rich molecular chemistry - including unusually luminous HC3N line emission. We furthermore detect: ortho-H2CO 2-1, 3-2; CN 1-0, 2-1; HCO+, 1-0. 3-2, HCN 3-2, HNC 1-0, 3-2 (and tentatively OCS 12-11). The HCN, HCO+, H2CO and CN line emission can be fitted to densities of n=5 x 10E4 - 10E5 cm-3 and gas temperatures Tk=80-150 K. Both HNC and HC3N are, however, significantly more excited than the other species which requires higher gas densities - or radiative excitation through e.g. mid-IR pumping. The HCN line intensity is fainter than that of HCO+ and HNC for the 3-2 transition, in contrast to previous findings for the 1-0 lines where the HCN emission is the most luminous. We tentatively suggest that the observed molecular line emission is consistent with a young starburst, where the emission can be understood as emerging from dense, warm ...
2007-01-01
Cosmic Evolution of Black Holes And Spheroids. 1, the M(BH)-Sigma Relation at Z=0.36
Energy Technology Data Exchange (ETDEWEB)
We test the evolution of the correlation between black hole mass and bulge velocity dispersion (M{sub BH} - {sigma}), using a carefully selected sample of 14 Seyfert 1 galaxies at z = 0.36 {+-} 0.01. We measure velocity dispersion from stellar absorption lines around Mgb (5175 {angstrom}) and Fe (5270 {angstrom}) using high S/N Keck spectra, and estimate black hole mass from the H{beta} line width and the optical luminosity at 5100 {angstrom}, based on the empirically calibrated photo-ionization method. We find a significant offset from the local relation, in the sense that velocity dispersions were smaller for given black hole masses at z = 0.36 than locally. We investigate various sources of systematic uncertainties and find that those cannot account for the observed offset. The measured offset is {Delta} log M{sub BH} = 0.62 {+-} 0.10 {+-} 0.25, i.e. {Delta} log {sigma} = 0.15 {+-} 0.03 {+-} 0.06, where the error bars ...
2006-04-17
Purpose: The purpose of this paper is to show how Nigeria's current Universal Basic Education on primary schooling targets Muslim "Almajiri" street boys for basic literacy acquisition. The paper examines the policy's management implementation practices and challenges, as well as provides policy options that may minimize discrepancies for effective management. Design/methodology/approach: The discussion is guided by preliminary qualitative studies using phenomenology research philosophy to better understand the social realities of the boys' schooling. Using a descriptive case study approach, two schools in a major city of northern Nigeria served as research sites. Data collection process involved informal interviews, active observations, and discussions with a purpose with four boys, and two teachers as primary participants. Data analysis engaged the generation of themes from the transcribed interview and personal observation field notes, with ...
2007-12-01
A High-Frequency Secondary Event During the 2004 M6.0 Parkfield Earthquake
We present an image of the rupture propagation of the 2004 M6.0 Parkfield earthquake using records from a dense network of local strong motion stations. We back-propagate high-frequency waveforms in 3D with a method, similar to reverse time migration, to obtain an estimate of the distribution of radiated high-frequency seismic energy in space and time. The image is forced to be coherent at the known hypocenter location and the quake origin time by applying small static time shifts obtained using waveform cross-correlation. We observe that the Parkfield earthquake radiated a distinct secondary high-frequency phase, which is located about 12.5~km northwest of the hypocenter with an onset of seismic radiation about 5~s after the rupture initiation. The time history of the back-projection suggests a rupture velocity of 2.5~km/s between hypocenter and subevent. The back-projection result is confirmed by inversion of picked arrival times of the secondary event clearly ...
2007-12-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 ...
2000-03-01
Simulations of the Microwave Sky
Energy Technology Data Exchange (ETDEWEB)
We create realistic, full-sky, half-arcminute resolution simulations of the microwave sky matched to the most recent astrophysical observations. The primary purpose of these simulations is to test the data reduction pipeline for the Atacama Cosmology Telescope (ACT) experiment; however, we have widened the frequency coverage beyond the ACT bands and utilized the easily accessible HEALPix map format to make these simulations applicable to other current and near future microwave background experiments. Some of the novel features of these simulations are that the radio and infrared galaxy populations are correlated with the galaxy cluster and group populations, the primordial microwave background is lensed by the dark matter structure in the simulation via a ray-tracing code, the contribution to the thermal and kinetic Sunyaev-Zel'dovich (SZ) signals from galaxy clusters, groups, and the intergalactic medium has been included, and the gas prescription to ...
2009-12-16
Energy Technology Data Exchange (ETDEWEB)
A Lawrence Livermore National Laboratory (LLNL) Management Pre-Start Review (MPR) Team was formed to independently verify the operational readiness of Building 368 (B368) Biosafety Level III (BSL-3) Facility to conduct research with biological pathogens and toxins including those considered Select Agents. Review objectives and criteria were developed from the DOE/NNSA and LLNL requirements. These were provided in the Implementation Plan for the Biosafety Level III (BSL-3) Facility Management Pre-Start Review (BSL-3 MPR) at Lawrence Livermore National Laboratory that was reviewed and approved by DOE/NNSA-LSO. The formal part of the LLNL MPR for the BSL-3 Facility was begun in August of 2005 but work on the MPR was stopped in October of 2005 due to the need for LLNL to reassess organizational and operational controls and respond to Centers for Disease Control and Prevention inquiries related to a shipping incident involving select agents. The MPR was restarted in mid-June of 2006. ...
2006-07-25
Precision Measurements of the Cluster Red Sequence using an Error Corrected Gaussian Mixture Model
Energy Technology Data Exchange (ETDEWEB)
The red sequence is an important feature of galaxy clusters and plays a crucial role in optical cluster detection. Measurement of the slope and scatter of the red sequence are affected both by selection of red sequence galaxies and measurement errors. In this paper, we describe a new error corrected Gaussian Mixture Model for red sequence galaxy identification. Using this technique, we can remove the effects of measurement error and extract unbiased information about the intrinsic properties of the red sequence. We use this method to select red sequence galaxies in each of the 13,823 clusters in the maxBCG catalog, and measure the red sequence ridgeline location and scatter of each. These measurements provide precise constraints on the variation of the average red galaxy populations in the observed frame with redshift. We find that the scatter of the red sequence ridgeline increases mildly with redshift, and that the slope decreases with ...
2009-07-01
Whole-body tumor staging: MRI or FDG-PET/CT?; Ganzkoerpertumorstaging: MRT oder FDG-PET/CT
Energy Technology Data Exchange (ETDEWEB)
Technical innovations such as the availability of movable patient platforms and the introduction of 32-channel systems have made whole-body MRI for tumor staging feasible. In addition, the development of dual-modality PET/CT systems offers the opportunity to perform anatometabolic tumor staging with whole-body coverage in a single session. Based on an increase in patient survival when applying a stage-adapted therapy in different malignant diseases the relevant question relates to the accuracies of whole-body MRI and whole-body PET/CT for TNM staging. This review article addresses whole-body tumor staging with MRI and FDG-PET/CT with special emphasis on diagnostic accuracies for staging different malignant diseases. (orig.) [German] Technische Neuerungen, wie die Verfuegbarkeit beweglicher Tischaufsaetze oder die Einfuehrung von 32-Kanal-Systemen, haben die Ganzkoerperbildgebung mit der MRT ermoeglicht. Die Entwicklung ...
2004-09-01
Studies on the mechanism of action of enterotoxin-induced fluid secretion in the gut
International Nuclear Information System (INIS)
The mechanism of action of Clostridium difficile enterotoxin A (CA), of Escherichia coli enterotoxin (STa) and of cholera toxin (CT), which are known to cause severe diarrhea, were studied in a preparation of ligated jejunal loops of anesthetized rats in vivo. The toxins were administered intraluminally. Pharmacological agents, which were tested for their potency to influence toxin-related effects, were administered subcutaneously. Net fluid transport was determined gravimetrically, prostaglandin (PG) E_2-output into the lumen, cyclic adenosine monophosphate (cAMP) and cyclic guanosine monophosphate (cGMP) contents in the mucosa were measured by radioimmunoassay, serotonin-(5-HT)-output into the lumen was determined by high performance liquid chromatography. The histopathological effects of CA and CT were examined by light- and scanning electron microscopy. All three toxins caused net fluid secretion (FS). 5-HT_2-(ketanserin) and ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, ...
2003-06-01
CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice
Energy Technology Data Exchange (ETDEWEB)
Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of ...
1992-07-15
CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice
International Nuclear Information System (INIS)
Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of ...
1992-07-01
Validity of the CT to attenuation coefficient map conversion methods
International Nuclear Information System (INIS)
The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.
2004-04-27
Trabecular scaffolds created using micro CT guided fused deposition modeling
British Library Electronic Table of Contents (United Kingdom)
Free form fabrication and high resolution imaging techniques enable the creation of biomimetic tissue engineering scaffolds. A 3D CAD model of canine trabecular bone was produced via micro CT and exported to a fused deposition modeler, to produce polybutylene terephthalate (PBT) trabeculated scaffolds and four other scaffold groups of varying pore structures. The five scaffold groups were divided into subgroups (n=6) and compression tested at two load rates (49?N/s and 294?N/s). Two groups were soaked in a 25??C saline solution for 7?days before compression testing. Micro CT was used to compare porosity, connectivity density, and trabecular separation of each scaffold type to a canine trabecular bone sample. At 49?N/s the dry trabecular scaffolds had a compressive stiffness of 4.94?1.19?MP...
2008-01-01
The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma
International Nuclear Information System (INIS)
The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).
PET/MRI hybrid imaging: devices and initial results
British Library Electronic Table of Contents (United Kingdom)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
2008-01-01
Dissection of the thoracic aorta - role of CT and MRT following aortic replacement
International Nuclear Information System (INIS)
Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is ...
Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics
International Nuclear Information System (INIS)
Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion.
3-D brain CT image display for planning of craniofacial operation
International Nuclear Information System (INIS)
The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).
Measurement of the charge asymmetry in top-antitop quark production with the CDF II experiment
Energy Technology Data Exchange (ETDEWEB)
The Fermi National Laboratory (Fermilab) operates the Tevatron proton-antiproton collider at a center-of-mass energy of {radical}s = 1.96 TeV, the is therefore the only collider which is today able to produce the heaviest known particle, the top quark. The top quark was discovered at the Tevatron by the CDF and D0 collaborations in 1995. At the Tevatron, most top quarks are produced via the strong interaction, whereby quark-antiquark annihilation dominates with 85%, and gluon fusion contributes with 15%. Considering next-to-leading order (NLO) contributions in the cross section of top-antitop quark production, leads to a slight positive asymmetry in the differential distribution of the production angle {alpha} of the top quarks. This asymmetry is due to the interference of certain NLO contributions. The charge asymmetry A in the cosine of {alpha} is predicted [14] to amount to 4-6%. Information about the partonic rest frame, necessary for a measurement of A in the ...
2006-12-01
[Single and 4-week oral toxicity studies of prulifloxacin (NM441) in aged dogs].
Single-dose and repeated dose toxicity studies of prulifloxacin, a new antibacterial agent, were conducted in aged beagle dogs. I. A single-dose toxicity study Prulifloxacin was administered orally to aged female dogs at a single dose of 2500 and 5000 mg/kg. No death occurred in any group. Vomiting was observed in one of two animals at 2500 mg/kg and in both animals at 5000 mg/kg 3-4 hr after dosing. At 5000 mg/kg, vomiting was observed in both animals after feeding on the day after dosing. One animal also showed soft stool. Thereafter, no abnormalities were observed in any animal. No test article related changes were noted in food consumption, water consumption, body weight or pathological examination in any group. The results show that the lethal dose of prulifloxacin is judged to be greater than 5000 mg/kg in aged female dogs. II. A repeated dose toxicity study Aged male and female dogs were given the test article orally ...
1996-06-01
The role of computed tomography in complex facial trauma
Energy Technology Data Exchange (ETDEWEB)
Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury ...
1988-02-15
UK PubMed Central (United Kingdom)
The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available
2010-01-01
TECAB - Totally Endoscopic Coronary Artery Bypass
... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...
Regulation of the brown and white fat gene programs through a PRDM16/CtBP transcriptional complex
UK PubMed Central (United Kingdom)
Brown fat is a specialized tissue that can dissipate energy and counteract obesity through a pattern of gene expression that greatly increases mitochondrial content and uncoupled respiration. PRDM16...Full Text Available
2008-05-15
UK PubMed Central (United Kingdom)
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
2008-04-01
UK PubMed Central (United Kingdom)
BackgroundTo evaluate the performance of three different advanced treatment techniques on a group of complex paediatric cancer cases.MethodsCT...Full Text Available
ORNL RSIC-18 - NASA Technical Report Server (NTRS)
W. Wayne Scott. ABSTRClCT. Primary proton and secondary particle doses (both .... W. Wayne Scott and R. G. Alsmiller, Jr., Comparisons of Results Ob- ...
Noise suppression in scatter correction for cone-beam CT
UK PubMed Central (United Kingdom)
Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available
2009-03-01
International Nuclear Information System (INIS)
The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential involvement or involvement of the entire pleura, thickness of more than 10 mm and nodular changes. The most reliable sign of ...
UK PubMed Central (United Kingdom)
BackgroundCavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other...Full Text Available
UK PubMed Central (United Kingdom)
ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available
2011-02-01
High resolution computed tomography in the study of cervical spine trauma
International Nuclear Information System (INIS)
Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently ...
1989-01-01
Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging
International Nuclear Information System (INIS)
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
International Nuclear Information System (INIS)
Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so ...
Ct3d: tracking microglia motility in 3D using a novel cosegmentation approach
UK PubMed Central (United Kingdom)
Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available
2011-02-15
Closed loop obstructions of the small bowel: role of Computed Tomography
International Nuclear Information System (INIS)
Small bowel obstructions can be distinguished into more simple and closed loop obstructions. The latter is a more severe condition which is often complicated by strangulation with vascular impairment, edema and intramural and mesenteric hemorrhage. Consequent arterial insufficiency rapidly leads to ischemia, infarction and necrosis. The radiologist plays a role in the early recognition of the closed loop obstruction and of any sign of strangulation. The role of CT in the diagnosis and workup of patients with suspected intestinal occlusion has been analyzed in the literature with reported 63% sensitivity, 78% specificity and 66% accuracy. CT is also capable of revealing the causes of occlusion in 73-95% of cases. The above CT signs allow to identify closed loop obstruction and also small bowel strangulation, thus supplying a valuable contribution to diagnosis and accurate preoperative evaluation. The conclusion is that ...
1999-01-01
International Nuclear Information System (INIS)
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)
2011-01-01
Body dose conversion factors for computerized tomography
International Nuclear Information System (INIS)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) ...
1980-10-31
International Nuclear Information System (INIS)
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)
2001-09-01
A three-dimensional display system for brain CT images
International Nuclear Information System (INIS)
Commercially available CT devices reconstruct cross-sectional slices of the human body. A sequence of such abutting cross-sectional slices can be, and usually is, used to obtain information about the region of the head, which requires several slices to cover it. However, there are situations for which such asequence of displays is far from optimal - for example, when one would like to see the anatomic relationship between two features appearing in different slices or the shape of a particular region or tumor. The Computer Aided Three-Dimensional Reconstruction and Imaging System (CATRIS), developed at our university, can build up a three-dimensional image from a series of CT cross-sections and can display its stereoscopic image on a three-dimensional graphic display system, thus providing helpful information for clinical use in recognizing the anatomic relationship between two features appearing in different slices or the shape of particular ...
A computer-assisted method for 3D subtraction angiography based on spiral CT
International Nuclear Information System (INIS)
The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the ...
A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT
UK PubMed Central (United Kingdom)
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
2010-01-01
Flow Vaporization of CO{sub 2} in Microchannel Tubes
Energy Technology Data Exchange (ETDEWEB)
Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have shown a clear dominance of nucleate boiling ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work is to investigate whether any morphometric or densitometric are detectable in the kidneys of type 2 diabetic patients. 40 diabetic patients were examined and of 20 non-diabetics (the control group) were submitted to triphasic helical CT for different abdominal conditions. The type 2 diabetic patients were 23 men and 17 women, mean age 62 years, while the nondiabetic controls were 12 men and 8 women, mean age 58 years. All the CT images were analyzed using the Multiplanar Reconstruction (MPR) software. It was evaluated morphometric features, such as the presence of parenchymal or vascular calcifications, axial and coronal renal diameters, coronal renal area, and cortico medullary ratio, and densitometric and functional features, such as unenhanced renal density, cortical and medullary density in the arterial phase, parenchymal density in the nephrographic phase, and contrast elimination. It was also compared the results ...
2000-02-01
Energy Technology Data Exchange (ETDEWEB)
Thermal (gas) nitridation of stainless steels can yield low interfacial contact resistance (ICR), electrically-conductive and corrosion-resistant nitride containing surfaces (Cr2N, CrN, TiN, V2N, VN, etc) of interest for fuel cells, batteries, and sensors. This paper presents the results of scale up studies to determine the feasibility of extending the nitridation approach to thin 0.1 mm stainless steel alloy foils for proton exchange membrane fuel cell (PEMFC) bipolar plates. A major emphasis was placed on selection of alloy foil composition and nitidation conditions potentially capable of meeting the stringent cost goals for automotive PEMFC applications. Developmental Fe-20Cr-4V alloy and type 2205 stainless steel foils were treated by pre-oxidation and nitridation to form low-ICR, corrosion-resistant surfaces. Promising behavior was observed under simulated aggressive anode- and cathode- side bipolar plate conditions for both materials. Variation in ICR values ...
2010-09-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
