WorldWideScience
 
 
1

Study of Tibial Shaft Fractures in Children  

Science.gov (United States)

Tibial Shaft Fractures in Children

2010-11-09

2

Absence of positive effect of black cohosh (Cimicifuga racemosa) on fracture healing in osteopenic rodent model  

British Library Electronic Table of Contents (United Kingdom)

Abstract The healing of predominantly metaphyseal fractures in postmenopausal osteoporosis is delayed and comparatively poor. Due to the potential side effects of HRT, natural alternatives are appealing. The aim of this study was to determine whether Cimicifuga racemosa extract BNO 1055 improves metaphyseal fracture healing in severe osteopenic bone in rats. Thirty three 12 week old female rats developed severe osteopenia during 10 weeks after ovariectomy. After metaphyseal tibial osteotomy and standardized T plate osteosynthesis, the healing periods in ovariectomized rats (C), 17 estradiol (E) and Cimicifuga racemosa (CR) supplemented diets were assessed for 35 days. Changes in callus morphology were evaluated qualitatively by biomechanical testing and quantitatively in microradiographies...

2010-01-01

3

The Prevention of Periodontal Bone Loss at the Osteotomy Site After Anterior Segmental and Dento-Osseous Osteotomy  

British Library Electronic Table of Contents (United Kingdom)

Purpose Degeneration of the gingival margin and periodontal bone loss between segments can occur in various segmental osteotomies. However, treatment and management of these problems have not yet been resolved; improvement of the conventional method is necessary. The purpose of this retrospective study is to evaluate the usefulness and advantage of orthodontic devices in osteotomies. Patients and Methods Forty Japanese adults presented with jaw deformities diagnosed as mandibular prognathism with maxillary protrusion, bimaxillary protrusion, and anterior crowding. Of these 40 patients, 20 (group 1) underwent anterior segmental osteotomy or dento-osseous osteotomy along with our original orthodontic periodontal management. The remaining 20 (group 2) patients underwent conventional procedure...

2006-01-01

4

Impingement fracture of the anteromedial tibial margin: a radiographic sign of combined posterolateral complex and posterior cruciate ligament disruption  

Energy Technology Data Exchange (ETDEWEB)

Marginal fractures of the tibial plateau are associated with a high incidence of soft tissue injuries to the stabilising structures of the knee joint. Injuries to the anterior cruciate ligament are associated with the Segond fracture and impingement fractures of the posteromedial tibial plateau. Recognition of these fractures aids diagnosis of these injuries. Marginal fractures of the tibial plateau associated with posterior cruciate ligament injuries are less common, though recently a ''reverse'' Segond fracture has been recognised. We describe a fracture of the anteromedial tibial plateau associated with complete disruption of the posterior cruciate ligament and posterolateral complex. (orig.)

2001-02-01

5

The Effect of Graded Recession and Anteriorization on Unilateral Superior Oblique Palsy  

UK PubMed Central (United Kingdom)

PurposeWe wanted to examine the effect of graded recession and anteriorization of the inferior oblique muscle on patients suffering from unilateral superior oblique palsy.MethodsInferior...Full Text Available

2006-09-01

6

Surgical approach for high-energy posterior tibial plateau fractures  

UK PubMed Central (United Kingdom)

Background:High-energy fractures of posterior tibial plateau always need surgical treatment. Generally, posterior fragments of these fractures could not be exposed and reduced...Full Text Available

2011-03-01

7

Posttraumatic tibia valga: a case demonstrating asymmetric activity at the proximal growth plate on technetium bone scan  

Energy Technology Data Exchange (ETDEWEB)

Posttraumatic tibia valga is a well-recognized complication following fracture of the upper tibial metaphysis in young children. We present a case of a child who developed a valgus deformity following fracture of the proximal tibia and fibula in which quantitative bone scintigraphy at 5 months after injury demonstrated increased uptake at the proximal tibial growth plate with proportionally greater uptake on the medial side. This finding suggests that the valgus deformity in this patient was due to a relative increase in vascularity and consequent overgrowth of the medial portion of the proximal tibial physis.

1987-07-01

8

Posttraumatic tibia valga: a case demonstrating asymmetric activity at the proximal growth plate on technetium bone scan  

International Nuclear Information System (INIS)

Posttraumatic tibia valga is a well-recognized complication following fracture of the upper tibial metaphysis in young children. We present a case of a child who developed a valgus deformity following fracture of the proximal tibia and fibula in which quantitative bone scintigraphy at 5 months after injury demonstrated increased uptake at the proximal tibial growth plate with proportionally greater uptake on the medial side. This finding suggests that the valgus deformity in this patient was due to a relative increase in vascularity and consequent overgrowth of the medial portion of the proximal tibial physis.

9

Failure of the Tibial Insert in a Rotating Hinge Total Knee Arthroplasty  

British Library Electronic Table of Contents (United Kingdom)

There has been a steady increase in the number of revision total knee arthroplasties being performed in the United States. Hinge knee prostheses are used predominantly in complex primary or revision arthroplasties, often as salvage procedures. Significant improvement of the articulation between the rotating hinge mechanism and tibial component has decreased the stresses that contributed to earlier failures in previous generation designs. Two cases of fracture of the tibial metal post in the rotating hinge of a revision total knee arthroplasty were evaluated and treated at our institution within a 1-month period. We present our experience with this construct failure and subsequent patient management.

2011-01-01

10

Selective Tibial Neurotomy in the Treatment of Spastic Equinovarus Foot in Hemiplegic Patients: A 2-Year Longitudinal Follow-Up of 30 Cases  

British Library Electronic Table of Contents (United Kingdom)

Deltombe T, Gustin T. Selective tibial neurotomy in the treatment of spastic equinovarus foot in hemiplegic patients: a 2-year longitudinal follow-up of 30 cases. Objective To assess the long-term efficacy of selective tibial neurotomy in the treatment of spastic equinovarus foot in hemiplegic patients. Design Intervention study (before-after trial) with an observational design and 2-year follow-up. Setting Spasticity group in a university hospital. Participants Hemiplegic patients (N=30) with spastic equinovarus foot. Intervention A selective neurotomy was performed at the level of the motor nerve branches of the tibial nerve. Main Outcome Measures Spasticity (Ashworth scale), muscle strength (Medical Research Council scale), passive ankle dorsiflexion, gait parameters (6 min walking test...

2010-01-01

11

Trigeminocardiac Reflex, Bilateral Sagittal Split Ramus Osteotomy, Gow-Gates Block: A Randomized Controlled Clinical Trial  

British Library Electronic Table of Contents (United Kingdom)

PurposeThe behavior of trigeminocardiac reflex (TCR) during maxillofacial surgeries has not yet been sufficiently studied and knowledge of its behavior is limited to some case reports. The present study aimed to assess the occurrence of TCR in bilateral sagittal split ramus osteotomy and to determine the possible effect of Gow-Gates block on its incidence. Materials and MethodsTwenty candidates for bilateral sagittal split ramus osteotomy (included were American Society of Anesthesiologists I Class III patients with a prognathism of 3 to 5 mm) were given routine general anesthesia after at least 12 hours of fasting. All patients received Gow-Gates mandibular nerve block on 1 random side (case ramus; the other side was used as the control) after induction of general anesthesia before surger...

2011-01-01

12

Orthognathic treatment with maxillary and mandibular anterior segmental osteotomy  

British Library Electronic Table of Contents (United Kingdom)

This case report presents a case that underwent orthognathic treatment with anterior segmental osteotomies on both jaws. The patient was a 26-year-old female with maxillary protrusion, lip incompetence with an everted vermilion border. The overbite was +1.0mm, overjet +1.0mm. The pre-surgical orthodontic treatment included the extraction of the four first premolars and a multi-bracket treatment was started. After 12 months of pre-surgical orthodontic treatment, both the anterior maxillary and the anterior mandibular segments were retracted surgically by 5.5mm. The total treatment period was 18 months. An anterior segmental osteotomy can induce the remarkable structural changes for bimaxillary lip protrusion patients.

2009-01-01

13

Facial soft tissue response to anterior segmental osteotomies: A systematic review  

British Library Electronic Table of Contents (United Kingdom)

Bimaxillary protrusion is prevalent among Asians and anterior segmental osteotomies are commonly used for its surgical correction. The objective of this study was to evaluate the soft tissue changes resulting from anterior segmental osteotomies. The electronic databases PubMed, Scopus and ISI Web of knowledge were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria were retrieved and their references were manually searched for additional relevant articles. The study details and outcome data of these reports were extracted using spreadsheets for comparison. The methodological quality of each study was assessed. Eleven studies met the inclusion criteria. Lateral cephalometry was used in all studies. A reduction of the lab...

2010-01-01

14

Evaluation of the Soft and Hard Tissue Changes After Anterior Segmental Osteotomy on the Maxilla and Mandible  

British Library Electronic Table of Contents (United Kingdom)

PurposeThe purpose of this study was to determine the relationship between the changes of soft and hard tissues after modified anterior segmental osteotomy on the maxilla and mandible and to evaluate unintended facial changes using cephalometric and photometric analyses.Materials and MethodsThe subjects included 29 women and 1 man (22 to 50 years of age) who were diagnosed as bialveolar or bimaxillary protrusion and underwent modified anterior segmental osteotomy on the maxilla and mandible. Lateral cephalograms and lateral and frontal photographs taken preoperatively and postoperatively were analyzed.ResultsThere was a significant change in all soft and hard tissue parameters except the labiomental angle. The ratio of upper lip to maxillary incisor retraction was 0.67:1 and the ratio of l...

2008-01-01

15

Tilt-a-Worlds: Effects of High Rates of Obliquity Change on the Habitability of Extrasolar Planets  

Science.gov (United States)

We explore the impact of obliquity variations on planetary habitability in hypothetical systems with high mutual inclination. For the hypothetical systems, we restrict our exploration to systems consisting of a solar-mass star, an Earth-mass planet at 1 AU, and 1 or 2 giant planets. We verify that these systems are stable for 108 years with N-body simulations. We then calculate the obliquity variations induced by the orbital architecture on the Earth-mass planets. We find that in some cases the spin axes can rotate through 360 degrees in as little as 10,000 years (John is that right? Can you look through the systems and find the most extreme case of obliquity variation?) Next, we run energy balance models (EBM) on the terrestrial planets to assess surface temperature and ice coverage on the planets' oceans. Finally, we explore differences in the outer edge of the habitable zone for planets with rapid ...

2011-01-01

16

Cell kinetics of growth cartilage of achondroplastic (cn) mice.  

UK PubMed Central (United Kingdom)

Mice homozygous for the recessive gene achondroplasia (cn) aged 16 and 17 days and some homozygotes aged 22-34 days have disruptions in the growth of the proximal tibial growth plate which are due solely...Full Text Available

1985-05-01

17

Postoperative pressure-induced alopecia after segmental osteotomy at the upper and lower frontal edentulous areas for distraction osteogenesis  

British Library Electronic Table of Contents (United Kingdom)

Introduction Postoperative alopecia is a relatively rare event, and therefore both patients and surgeons are puzzled once it develops even though it is said to improve spontaneously with time in most cases. We report a parieto-occipital pressure-induced alopecia firstly developed in a patient who had undergone repeated surgery for 10?years after a traffic accident. Case report A 29-year-old male underwent segmental osteotomy at the upper and lower frontal edentulous areas for distraction osteogenesis. Throughout the operation, he was in the supine position with the hair covered with a paper cap and the head on a plastic vinyl chloride-covered soft foam horseshoe-shaped urethane sponge placed on the horseshoe-shaped headrest. About 2?weeks after the surgery, two patches of parieto-occipital...

2011-01-01

18

Orthognathic treatment case after severe root resorption in the early treatment stage  

British Library Electronic Table of Contents (United Kingdom)

This article presents an orthognathic treatment case after severe apical root resorption of maxillary anterior teeth using anterior segmental osteotomy. This case involved a 20-year-old female with the chief complaint of maxillary protruding and irregularly aligned mandibular anterior teeth. Her medical history showed no allergies or medical problems. The overbite was +3.0mm, and the overjet +3.0mm. After extraction of the four first premolars, a multi-bracket treatment was started. A severe root resorption of the maxillary anterior teeth was found 12 months after active treatment. The maxillary anterior segmental osteotomy was chosen as the compensatory treatment. The total treatment period was 2 years and 7 months. The post-retention panoramic radiograph showed no developmental root reso...

2009-01-01

19

Split anterior tibial tendon transfer for varus equinus spastic foot deformity  

British Library Electronic Table of Contents (United Kingdom)

Spastic equinovarus foot deformity commonly occurs after stroke or head trauma. Management by split anterior tibial tendon transfer to the lateral border of the foot was chosen by the authors. The purpose of that work was to assess the reliability of this method to improve patient's functional autonomy and investigate the relationship between the initial clinical examination findings and the quality of the functional results. 84 feet, operated in 82 patients out of 130, of mean age 46 years, were reviewed at a mean follow-up of 65 months. Very few complications were observed. Toe deformities remain a commonly associated problem. 80 patients were able to walk barefoot, 74 reported an increase in their walking distance, and 73 could regularly wear normal shoes. There is a strong relationship...

2011-01-01

20

Simulation of the filtration mechanism of hyaluronic acid in total knee prosthesis  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint.

2007-11-15

 
 
 
 
21

Correction of skeletal Class II-anterior deep bite and prominent chin by forced surgical rotation of the mandible  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this paper is to describe a technique of forced surgical rotation of the mandible used in skeletal Class II patients with deep bite and prominent chin. Posterior occlusal composite onlays combined with preoperative orthodontic treatment without anterior intrusion increase the posterior rotational component of the surgical mandibular advancement, when removed during operation. This manoeuvre allows for the surgical closure of the posterior open bite, while anteriorly the deep bite is opened. This technique avoids bimaxillary rotation surgery with dorsal impaction in mild to moderate cases. In any case, a chin setback osteotomy with compromised aesthetics can be avoided.

2010-01-01

22

Evaluation of aseptic loosening of knee prostheses by quantitative bone scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

In not infected knee prostheses bone scintigraphy is a possible method to diagnose mechanical loosening, and therefore, to affect treatment regimes in symptomatic patients. However, hitherto studies showed controversial results for the reliability of bone scintigraphy in diagnosing loosened knee prostheses by using asymptomatic control groups. Therefore, the aim of our study was to optimize the interpretation procedure and to evaluate the accuracy using results from revision surgery as standard. Methods: Retrospectively, we were able to examine the tibial component in 31 cemented prostheses. In this prostheses infection was excluded by histological or bacteriological examination during revision surgery. To quantify bone scintigraphy, we used medial and lateral tibial regions with a reference region from the contralateral femur. Results: to differentiate between loosened and intact prostheses we found a threshold of 5.0 for the maximum tibia to ...

2008-07-01

23

Evaluation of aseptic loosening of knee prostheses by quantitative bone scintigraphy  

International Nuclear Information System (INIS)

In not infected knee prostheses bone scintigraphy is a possible method to diagnose mechanical loosening, and therefore, to affect treatment regimes in symptomatic patients. However, hitherto studies showed controversial results for the reliability of bone scintigraphy in diagnosing loosened knee prostheses by using asymptomatic control groups. Therefore, the aim of our study was to optimize the interpretation procedure and to evaluate the accuracy using results from revision surgery as standard. Methods: Retrospectively, we were able to examine the tibial component in 31 cemented prostheses. In this prostheses infection was excluded by histological or bacteriological examination during revision surgery. To quantify bone scintigraphy, we used medial and lateral tibial regions with a reference region from the contralateral femur. Results: to differentiate between loosened and intact prostheses we found a threshold of 5.0 for the maximum tibia to ...

24

Magnetic and structural investigation of magnetic thin films with obliquely deposited underlayers  

CERN Document Server

An in-plane uniaxial magnetic anisotropy has been observed in thin Co films normally deposited onto obliquely sputtered Ta and Pt underlayers. Associated with this anisotropy is an augmented easy axis coercivity. The in-plane easy axis is, in most cases, perpendicular to the incident deposition plane. Microstructural results indicate that grains are well connected along the magnetic easy axis but are separated by long continuous voids along the hard axis, which is ascribed to a geometric shadowing effect due to the oblique incidence deposition of the underlayer. Hence, the magnetic anisotropy mimics the film growth anisotropy. It is therefore believed that the observed magnetic properties are due to magnetostatic shape anisotropy effects. In-plane coercivity and anisotropy field are shown to increase with underlayer deposition angle, underlayer thickness and magnetic layer thickness. The choice of capping layer is also observed to dramatically ...

2002-01-01

25

The Effective Weak Mixing Angle In the MSSM  

CERN Document Server

The predictions of the MSSM are discussed in the light of recent LEP and SLD precision data. The full supersymmetric one loop corrections to the effective weak mixing angle, experimentally determined in LEP and SLD experiments, are considered. It is demonstrated, both analytically and numerically, that, potentially dangerous, large logarithmic sparticle corrections are cancelled. The relative difference factor \\Delta k between the mixing angle defined as a ratio of couplings and the experimentally obtained angle is discussed. It is found that \\Delta k is dominated by the oblique corrections, while the non-oblique overall supersymmetric EW and SQCD corrections are negligible. The comparison of the MSSM with radiative electroweak symmetry breaking to the LEP precision data indicates that rather large values of the soft breaking parameter M_{1/2} in the region greater than 500 GeV are preferred.

1999-01-01

26

Gouge initiation in high-velocity rocket sled testing  

Energy Technology Data Exchange (ETDEWEB)

A model is presented which describes the formation of surface damage ``gouging`` on the rails that guide rocket sleds. An unbalanced sled can randomly cause a very shallow-angle, oblique impact between the sled shoe and the rail. This damage phenomenon has also been observed in high-velocity guns where the projectile is analogous to the moving sled shoe and the gun barrel is analogous to the stationary rail. At sufficiently high velocity, the oblique impact will produce a thin hot layer of soft material on the contact surfaces. Under the action of a normal moving load, the soft layer lends itself to an anti-symmetric deformation and the formation of a ``hump`` in front of the moving load. A gouge is formed when this hump is overrun by the sled shoe. The phenomenon is simulated numerically using the CTH strong shock physics code, and the results are in good agreement with experimental observation.

1994-07-01

27

A study on effects of parameters in the Lagrangian code based on F.E.M. through oblique dual-plates perforation phenomena  

International Nuclear Information System (INIS)

This study is concerned to the perforation phenomena of the oblique dual-plate by projectile. Experiment and simulation related to that was carried out. the variables considered in this phenomena include the electrolytic zinc coated steel sheet and carbon steel rod. In the former, the confirmation and projectile velocity possible phenomena of real phenomena is done, the latter, the effect of parameter such as time-step and grid space length is analyzed by using the three-dimensional Lagrangian explicit time-integration finite element code, HEMP. This code use the eight node hexahedral elements and in this study, Von-Mises Criteria is used as the strength model, Mie-Gruneisen is as the Equation of State. The simulation was performed by contrast with the experiment. Through the calibration of the parameter of Lagrangian code, reasonable result was approached.

2004-11-03

28

Quantitative bone scintigraphy in the evaluation of angular deformity of the lower extremity  

International Nuclear Information System (INIS)

A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 31 children (22 normal, 9 with angular deformity). Normal ratios were 0.74 to 0.98 for femora and 0.98 to 1.20 for tibias. In eight of nine patients with deformity, the ratio was abnormal; in two patients the ratio returned to normal when the deformity ceased to progress.

29

For early diagnosis of the fracture healing, nonunion and avascular necorsis  

Energy Technology Data Exchange (ETDEWEB)

Complications of non-union and avascular necrosis during fracture healing process are the most important problems. Early detection of the evidence of non-union and avascular necrosis and follow-up study of fracture healing process will reduce complications and sequellae in fracture patients. Femoral neck and tibial shaft are the most important fracture sites where non-union and/or avascular necorsis are frequently developed. Osteomedullography was performed in 30 cases of fracture, 21 femoral neck, 8 tibial shafts and 1 talar neck, in the Department of Radiology of national Medical Center during the period form August 1977 to March 1981. The following results were obtained: 1. 16 patients of femoral neck fracture were performed osteomedullography one. Non-union showing no crossing vein through the fracture site was noted in 12 cases from 16 patients. 4 cases from the 12 patients of non-union showed decreased viability but 2 case revealed good ...

1981-09-15

30

Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?  

Energy Technology Data Exchange (ETDEWEB)

(1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular ...

2007-02-15

31

Relationships of the Lateral Femoral Cutaneous Nerve to Bony Landmarks  

British Library Electronic Table of Contents (United Kingdom)

Background The lateral femoral cutaneous nerve (LFCN) can be at risk during, for example, the insertion of pins in the anterior superior iliac spine (ASIS) during external fixation of the pelvis, total hip arthroplasty through a direct anterior approach, open surgery for impingement in the hip through an anterior approach, and periacetabular osteotomy. During surgery, the surgeon usually assumes the location of the LFCN by using the ASIS as a landmark. Questions/purposes We investigated (1) whether there is any relationship between the LFCN and the ASIS and (2) the anatomy of the LFCN at the lateral border of the psoas major. Methods Using 25 formalin-fixed cadavers, we determined the location of the LFCN emergence point as above, same level with, or below the iliac crest (IC). We measured...

2011-01-01

32

Do Estrogen and Alendronate Improve Metaphyseal Fracture Healing When Applied as Osteoporosis Prophylaxis?  

British Library Electronic Table of Contents (United Kingdom)

Osteoporosis is accompanied by predominantly metaphyseal fractures with a delayed and qualitatively reduced healing process. This study addressed the question of whether fracture healing in the context of osteoporosis prophylaxis is improved with estrogen (E) or alendronate (ALN). Thirty-six ovariectomized and 12 sham-operated 12-week-old rats received soy-free (osteoporotic C, sham), E-, or ALN- supplemented diets. After 10?weeks, a metaphyseal tibia osteotomy and standardized T-plate fixation were performed. After a 5-week healing process, the fracture callus was evaluated qualitatively by biomechanical bending test and quantitatively in microradiographic sections. The time course of callus formation was examined using fluorochrome-labeled histological sections. Administration of E impro...

2010-01-01

33

Combined In Vivo/In Silico Study of Mechanobiological Mechanisms During Endochondral Ossification in Bone Healing  

British Library Electronic Table of Contents (United Kingdom)

Mechanobiological theories have been introduced to illustrate the interaction between biology and the local mechanical environment during bone healing. Although several theories have been proposed, a quantitative validation using histomorphometric data is still missing. In this study, in vivo histological data based on an ovine animal experiment was quantified and used to validate bone healing simulations focussing on the endochondral ossification process. The bone formation at different callus regions (periosteal and endosteal bone at the medial and lateral side) was analyzed from in vivo data and quantitatively compared with in silico results. A histomorphometric difference was found in medial and lateral hard callus formation 3 weeks after osteotomy. However, the same amount of new bone...

2011-01-01

34

The formation of vertically aligned biaxial tungsten nanorods using a novel shadowing growth technique  

International Nuclear Information System (INIS)

Biaxially textured tungsten nanorods (A15 crystal structure) have been grown by oblique angle DC magnetron sputtering using a novel rotation mode called 'two-step rotation'. In this mode, the substrate is given a fast rotation through 1800 at 90 rpm and this is followed by a rest period of 30 s. These nanorods are vertically aligned and have a [100] texture normal to the substrate along with preferential in-plane texture as shown by x-ray pole figure analysis. In contrast, the tungsten nanorods obtained without substrate rotation are slanted at an angle of ?450 and have a [100] texture tilted 160 with respect to the substrate normal. The flux is incident from two diametrically opposite points on the sample at an oblique angle, averaging out the growth into vertical columns that retain the in-plane texture. Scanning electron microscopy shows that the tungsten nanorods have a mixture of {211} and {421} crystal habits; these planes are both ...

2009-11-18

35

The effects of a calcium deficient diet on the mechanical properties and morphology of goose bone.  

Science.gov (United States)

A control group of geese (Anser anser) on a normal calcium diet for egg laying poultry was compared to egg laying geese on a calcium deficient diet. The ultimate compressive strength and modulus of elasticity of femoral cortical bone from each group were determined by compressing right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The bending strength and bending modulus of elasticity of tibial cortical bone were determined by three point bend tests on rectangular prisms which were approximately 25 mm by 0.8 mm by 0.8 mm. Bone calcium content and eggshell calcium content were determined by atomic absorption spectrophotometry. Blood samples were analyzed for free calcium ion concentration. Histological observations included studies of cross-sectional microradiographs, examinations of cross sections stained by a modified Masson's technique, and a determination of fractional area of voids by quantitative microscopy. The average compressive ...

1986-01-01

36

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

37

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

38

Effect of local irradiation on longitudinal bone growth in the rat. A tetracycline labelling investigation  

Energy Technology Data Exchange (ETDEWEB)

Young rats were given a single irradiation dose (0.5, 2, 5 or 8 Gy) to the left knee-joint. The right unexposed knee-joint served as control. The animals were decapitated 1.5, 3, 7, 14 or 30 days after the irradiation. Longitudinal bone growth in the tibial epiphysis was established using tetracycline as an intravital marker. During the first 1.5 days after irradiation with 5 and 8 Gy, the growth was slightly inhibited (6-7%). Maximum growth retardation (20%) was found 7 to 14 days after irradiation with 5 and 8 Gy. No consistent effect occurred after 0.5 and 2 Gy. Between 14 to 30 days following irradiation growth was normalized.

1983-01-01

39

Amputee Independent Prosthesis Properties-A new model for description and measurement.  

Science.gov (United States)

A model is presented for describing the Amputee Independent Prosthesis Properties (AIPP) of complete assemblies of trans-tibial prosthetic components distal to the socket. This new AIPP model includes features of both lumped parameter and roll-over models and describes prosthesis properties that are of importance in stance phase, including prosthetic foot geometry, normal stiffness, shear stiffness, and damping (energy dissipation). Methods are described for measuring the parameters of the AIPP model using a custom test-rig, commercial load-cell, and a motion capture system. Example data are presented for five pylon angles reflecting the shank angles seen in normal gait. Through the inclusion of measured AIPP in future in-vivo studies comparing different prostheses more generic information, as opposed to product specific claims, will become more widely available to inform future designs, prescription, and alignment procedures. PMID:21831379

2011-08-09

40

Small hemielliptic dielectric lens antenna analysis in 2-D: boundary integral equations versus geometrical and physical optics  

CERN Document Server

We assess the accuracy and relevance of the numerical algorithms based on the principles of Geometrical Optics (GO) and Physical Optics (PO) in the analysis of reduced-size homogeneous dielectric lenses prone to behave as open resonators. As a benchmark solution, we use the Muller boundary integral equations discretized with trigonometric Galerkin scheme that has guaranteed and fast convergence as well as controllable accuracy. The lens cross-section is chosen typical for practical applications, namely an extended hemiellipse whose eccentricity satisfies the GO focusing condition. The analysis concerns homogeneous lenses made of rexolite, fused quartz, and silicon with the size varying between 3 and 20 wavelengths in free space. We consider the 2-D case with both E- and H-polarized plane waves under normal and oblique incidence, and compare characteristics of the near fields.

2010-01-01

 
 
 
 
41

Interfacial ultrafine-grained structures on aluminum alloy 6061 joint and copper alloy 110 joint fabricated by magnetic pulse welding  

British Library Electronic Table of Contents (United Kingdom)

Magnetic pulse welding is a solid state impact welding process, similar to explosive welding, which produces metallurgical bond by oblique high-speed impact between two metal bodies. This violent impact removes the metal surface oxide layers and then joins the two atomic level clean metal surfaces together by the incidental compression pressure. The impact velocity is at 200?400?m/s and the being welded metal surface undergoes severe plastic deformation with strain rate in the order of 106?107?s?1. The ultrafine-grained structure was observed on the welded interface. This article studied two types of similar material lap joint interfaces and the base metals were aluminum alloy 6061 and copper alloy 110. Nano-indentation testing shows that the welded interfaces have significantly greater ha...

2010-01-01

42

Implementation and modification of a three-dimensional radiation stress formulation for surf zone and rip-current applications  

British Library Electronic Table of Contents (United Kingdom)

Regional Ocean Modeling System (ROMS v 3.0), a three-dimensional numerical ocean model, was previously enhanced for shallow water applications by including wave-induced radiation stress forcing provided through coupling to wave propagation models (SWAN, REF/DIF). This enhancement made it suitable for surf zone applications as demonstrated using examples of obliquely incident waves on a planar beach and rip current formation in longshore bar trough morphology (Haas and Warner, 2009). In this contribution, we present an update to the coupled model which implements a wave roller model and also a modified method of the radiation stress term based on Mellor (2008, 2011a,b,in press) that includes a vertical distribution which better simulates non-conservative (i.e., wave breaking) processes and ...

2011-01-01

43

Geometry of elastic hydrofracturing by injection of an over pressured non-Newtonian Fluid  

CERN Document Server

The nucleation and propagation of hydrofractures by injection of over pressured fluids in an elastic and isotropic medium are studied experimentally. Non-Newtonian fluids are injected inside a gelatine whose mechanical properties are assumed isotropic at the experimental strain rates. Linear elastic theory predicts that plastic deformation associated to breakage of gelatin bonds is limited to a small zone ahead of the tip of the propagating fracture and that propagation will be maintained while the fluid pressure exceeds the normal stress to the fracture walls (Ch\\'avez-\\'Alvarez,2008) (i.e., the minimum compressive stress), resulting in a single mode I fracture geometry. However, we observed the propagation of fractures type II and III as well as nucleation of secondary fractures, with oblique to perpendicular trajectories with respect to the initial fracture. In the Video (http://hdl.handle.net/1813/14122) experimental evidence shows that the fracture shape ...

2009-01-01

44

Electron cyclotron resonance heating and current drive  

Energy Technology Data Exchange (ETDEWEB)

A brief summary of the theory and experiments on electron- cyclotron heating and current drive is presented. The general relativistic formulation of wave propagation and linear absorption is considered in some detail. The O-mode and the X-mode for normal and oblique propagation are investigated and illustrated by several examples. The experimental verification of the theory in T-10 and D- III-D is briefly discussed. Quasilinear evolution of the momentum distribution and related applications as, for instance, non linear wave, damping and current drive, are also considered for special cases of wave frequencies, polarization and propagation. In the concluding section we present the general formulation of the wave damping and current drive in the absence of electron trapping for arbitrary values of the wave frequency. (Author) 13 refs.

1992-07-01

45

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is considered the method ...

46

Application of high velocity impact welding at varied different length scales  

British Library Electronic Table of Contents (United Kingdom)

Three complementary impact welding technologies are described in this paper. They are explosive welding, magnetic pulse welding, and laser impact welding, which have been used to provide metallurgical bonds between both similar and dissimilar metal pairs. They share the physical principle that general impact-driven welding can be carried out by oblique impact but are used at different length scales from meters to sub-millimeter. The different length scales require different kinds of systems to drive the process, and the scales themselves can give different weld morphologies. Metallographic analysis on cross-sections shows a wavy interface morphology which is likely the result of an instability associated with jetting, which scours the surfaces clean during impact. The normalized period and...

2011-01-01

47

Observations on the contributions of environmental restraints and innate stem cell ability to hematopoietic regeneration  

Energy Technology Data Exchange (ETDEWEB)

A competitive repopulation assay utilizing chromosome markers was used to assay the reconstituting potential of hematopoietic populations. The test populations consisted of tibial murine marrow locally irradiated with doses ranging from 1.5 Gy to 8.5 Gy and of marrow generated from either murine splenic or marrow stem cells. The purpose of this assay was to assess the innate proliferative potential and microenvironmental influences on the ability to repopulate. Regardless of origin, spleen repopulating ability consistently agreed with spleen colony-forming unit (CFU-s) content. Doses of radiation from 5 Gy to 8.5 Gy diminished, by a factor of 2, the ability to repopulate marrow despite maintenance of CFU-s levels. Marrow generated from splenic stem cells had one-fifth the repopulating ability of marrow derived from marrow stem cells, even though CFU-s levels were equivalent. The results imply that the splenic environment can only maintain stem cells at the level of ...

1988-03-01

48

New stent developments for peripheral arterial occlusive disease; Neue Stententwicklungen fuer die periphere arterielle Verschlusskrankheit  

Energy Technology Data Exchange (ETDEWEB)

Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der primaeren ...

2010-01-15

49

Sub-0.1 #mu#m line fabrication by Focused ion beam and columnar structural Se-Ge resist  

International Nuclear Information System (INIS)

As a method to enhance the sensitivity (S) of an inorganic resist for focused-ion-beam (FIB), lithography, sub-0.1 #mu#m patterning properties of a columnar structural #alpha#-Se_7_5Ge_2_5 resist have been investigated using 30 keV low-energy Ga"+-FIB exposure and CF_4 reactive-ion etching (RIE). development. The Se_7_5Ge_2_5 thin films were 60 .deg. and 80 .deg. -obliquely deposited on Si substrate and parts of the films were annealed for several minutes at the glass transition temperature (T_g=#approx#220 .deg. C). Columnar structures with the angles of approximately 40 .deg. and 65 .deg. are observed in 60 .deg. and 80 .deg. -obliquely deposited films, respectively, and they disappear after annealing. Despite the disappearance of the columnar structures, a critical decrease in thickness is not observed. For the FIB exposures with a beam diameter of #approx#0.1#mu#m and around the threshold dose, the negative-type fine patterns with linewidth ...

1998-11-01

50

Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration  

CERN Document Server

It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral indices discerned in prompt burst ...

2010-01-01

51

Turnover of texture in low rate sputter-deposited nanocrystalline molybdenum films  

International Nuclear Information System (INIS)

The crystallite size and orientation in molybdenum films prepared by magnetron sputtering at a low rate of typical 1 (angstrom)s and a pressure of 0.45 Pa was investigated by X-ray diffraction and texture analysis. The surface topography was studied using atomic force microscopy. Increasing the film thickness from 20 nm to 3 microm, the films show a turnover from a (110) fiber texture to a (211) mosaic-like texture. In the early state of growth (20 nm thickness) the development of dome-like structures on the surface is observed. The number of these structures increases with film thickness, whereas their size is weakly influenced. The effect of texture turnover is reduced by increasing the deposition rate by a factor of six, and it is absent for samples mounted above the center of the magnetron source. The effect of texture turnover is related to the bombardment of the films with high energetic argon neutrals resulting from backscattering at the target under oblique ...

1997-04-04

52

Trishear fault-propagation folding  

Energy Technology Data Exchange (ETDEWEB)

Previous models of fault-propagation folding used kink-band geometries to approximate folding in front of propagating thrusts. However, kink-band kinematics cannot replicate the curved fold surfaces and complex strain patterns innatural and experimental fault-propagation folds, which also occur in front of steeper reverse and normal faults. Fault-propagation fold hinges tighten and converge downward, forming a triangular zone of penetrative deformation focused on the tip of the propagating fault. The downward convergence of deformation in fault-propagation folds can be modeled as triangular shear zones. Trishear, here defined as distributed, strain-compatible shear in a triangular (in profile) shear zone, provides an alternate kinematic model for fault-propagation folds. Trishear is analogous to simple shear in a tabular shear zone except that area balance in a triangular shear zone requires curved displacement oblique to the fault slip direction. Incremental ...

1991-06-01

53

The Effect of Lunar-like Satellites on the Orbital Infrared Light Curves of Earth-analog Planets  

CERN Document Server

We investigate the influence of lunar-like satellites on the infrared orbital light curves of Earth-analog extra-solar planets. Such light curves will be obtained by NASA's Terrestrial Planet Finder (TPF) and ESA's Darwin missions as a consequence of repeat observations to confirm the companion status of a putative planet. We use an energy balance model to calculate disk-averaged infrared (bolometric) fluxes from planet-satellite systems over a full orbital period (one year). The satellites are assumed to lack an atmosphere, have a low thermal inertia like that of the Moon and span a range of plausible radii. The planets are assumed to have thermal and orbital properties that mimic those of the Earth while their obliquities and orbital longitudes of inferior conjunction remain free parameters. Even if the gross thermal properties of the planet can be independently constrained (e.g. via spectroscopy or visible-wavelength detection of specular glint from a surface ...

2008-01-01

54

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. ...

2001-04-01

55

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. Further, optimal ...

2001-04-01

56

Radial distribution of superthermal electrons measured with ECE (abstract)  

International Nuclear Information System (INIS)

To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution function may be obtained from these data. A superheterodyne receiver at 60--90 GHz has ...

0854-01-01

57

Probes of Diffusive Shock Acceleration using Gamma-Ray Burst Prompt Emission  

CERN Document Server

The principal paradigm for gamma-ray bursts (GRBs) suggests that the prompt transient gamma-ray signal arises from multiple shocks internal to the relativistic expansion. This paper explores how GRB prompt emission spectra can constrain electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The array of possible high-energy power-law indices in accelerated populations is highlighted, focusing on how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. When encompassing the MeV-band spectral break, fits to BATSE/EGRET burst data indicate that the preponderance of electrons responsible for the prompt emission reside in an intrinsically non-thermal population. This differs markedly from typical populations generated in acceleration simulations; potential resolutions of this conflict such as the action of self-absorption are mentioned. ...

2009-01-01

58

Physical model experiment for wave field measurements by means of laser Doppler vibrometer. Measurement of three components; Laser Doppler shindokei ni yoru butsuri model jikken. Hado sanseibun no kenshutsu  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, a beam incident from an oblique direction is reflected by a spherical lens toward the direction of incidence. When the surface of a matter is vibrated by elastic waves, the spherical lens comes into a translation motion that accompanies the vibration. It follows accordingly that the vibration on the surface of the matter may be detected by sensing the spherical lens travelling speed. Three components of the vibration may be determined if beams are focused at one spot from three directions. Detection of the S-wave component by LDV (laser Doppler vibrometer) discloses the complicated wave field in a heterogeneous material, and this physical model experiment may be utilized in various fields of study. For instance, information about problems that may surface in the field work may be collected beforehand in a physical model experiment for developing an S-wave-aided probing method. For the study of seismic wave propagation in a complicated ...

1997-05-27

59

Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria  

British Library Electronic Table of Contents (United Kingdom)

In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26mGy to 21.26mGy for the mediolateral oblique (MLO) views and 0.08mGy to 5.36mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07mGy to 3.57mGy for the MLO views and 0.02mGy to 0.98mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean...

2009-01-01

60

Magnetic resonance imaging of the hip with a pelvic phased-array surface coil: a technical note  

Energy Technology Data Exchange (ETDEWEB)

Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer phased-array surface coils and may play an ...

1998-02-01

 
 
 
 
61

IC 4767 (the X-galaxy) - the missing link for understanding galaxies with peanut-shaped bulges?  

International Nuclear Information System (INIS)

Photometric and kinematic observations of the peculiar S0 galaxy IC 4767, the X-galaxy, are presented. At various intensities the bulge of this galaxy looks like a normal spheroidal system with elliptical isophotes, a well-defined rectangle, and a peanut-shaped or X-shaped structure with components aligned at oblique angles to the major axis. The observations reveal a rapidly rotating inner disk of gas and dust which is nearly aligned with the major axis. The presence of gaseous emission alone suggests an accretion event. The stars in the outer regions of the X-component are rotating nearly as rapidly as the gas in the main disk, indicating that they are in relatively circular orbits. The five most prominent peanut-shaped bulges all have several nearby companions, evidence that the peanut deformity is due to interaction between galaxies. An analogy with the formation mechanism proposed for polar-ring galaxies suggests how an X-shaped component could develop from ...

1988-01-01

62

Experimental evaluation of angularly-variable fiber geometry for targeting depth-resolved reflectance from layered epithelial tissue phantoms  

Science.gov (United States)

The aim of the present study focuses on experimentally demonstrating the efficacy of using angularly-variable fiber geometry to achieve the desired tissue-layer selection and probing depths with the further objective of enhancing the sensitivity and specificity of spectral diagnosis in stratified architectures that resemble human cervical epithelia. The morphological and biochemical features of epithelial tissue vary in accordance with tissue depths; consequently, the accuracy of spectroscopic diagnosis of epithelial dysplasia may be enhanced by probing the optical properties of this tissue. When correlated to cellular dysplasia, layer-specific changes in tissue optical properties may be deciphered by reflectance spectroscopy coupled with angularly-variable fiber geometry. This study addresses the utility of using such angularly-variable fiber geometry for resolving spatially-specific spectral signatures of tissue pathology. This is accomplished by interpreting and analyzing the ...

2007-03-01

63

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor methods. Various authors ...

1985-04-25

64

DMSA scan nomograms for renal length and area: Related to patient age and to body weight, height or surface area  

International Nuclear Information System (INIS)

Aim: To create nomograms for renal size as measured from DMSA renal studies, and to test the nomograms for their ability to separate normal from abnormal kidneys. Method: Renal length was measured from posterior oblique views and renal area from posterior views. Results from 253 patients with bilateral normal kidneys were used to create nomograms for renal size relative to patient age, body height, weight or body surface area (BSA). The nomograms enclosed 95% of the normal kidneys, thus indicating the range for 95% confidence limits, and hence the specificity. Each nomogram was then tested against 46 hypertrophied kidneys and 46 damaged kidneys. Results: The results from nomograms of renal length and renal area, compared to age, body height, body weight and BSA are presented. For each nomogram, the range is presented as a fraction of the mean value, and the number of abnormal kidneys (hypertrophied or damaged) outside the normal range is presented as a percentage ...

2002-09-01

65

Can magnetospheric electron temperature be inferred from whistler dispersion measurements  

International Nuclear Information System (INIS)

An approximate expression for whistler-mode group velocity is obtained, taking into account the effects of electron temperature and anisotropy, density and ion effects, effects of oblique propagation and a non-dipolarity of the dayside magnetospheric magnetic field. This expression is applied to the propagation of whistlers between one hemisphere and the other. It is pointed out that at frequencies close to the upper cut-off of whistler spectra, perturbations to whistler group delay times due to temperature effects can be of the same order of magnitude as, or even higher than, the corresponding perturbations due to finite electron density and ion effects. A method of magnetospheric electron temperature diagnostics is proposed and applied to two whistlers recorded at Halley (L = 4.3). It is pointed out that the values of temperature obtained from the analysis of whistler spectra depend on the choice of model of electron density and temperature distribution in the ...

66

Blending of nanoscale and microscale in uniform large-area sculptured thin-film architectures  

CERN Document Server

The combination of large thickness ($>3$ $\\mu$m), large--area uniformity (75 mm diameter), high growth rate (up to 0.4 $\\mu$m/min) in assemblies of complex--shaped nanowires on lithographically defined patterns has been achieved for the first time. The nanoscale and the microscale have thus been blended together in sculptured thin films with transverse architectures. SiO$_x$ ($x\\approx 2$) nanowires were grown by electron--beam evaporation onto silicon substrates both with and without photoresist lines (1--D arrays) and checkerboard (2--D arrays) patterns. Atomic self--shadowing due to oblique--angle deposition enables the nanowires to grow continuously, to change direction abruptly, and to maintain constant cross--sectional diameter. The selective growth of nanowire assemblies on the top surfaces of both 1--D and 2--D arrays can be understood and predicted using simple geometrical shadowing equations.

2003-01-01

67

Three-dimensional evaluation of cartilage thickness and cartilage volume in the knee joint with MR imaging: reproducibility in volunteers; Dreidimensionale Dicken- und Volumenbestimmung des Kniegelenkknorpels mit der MRT: Reproduzierbarkeit am Probanden  

Energy Technology Data Exchange (ETDEWEB)

Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in the medial tibial plateau and 3.5% ({+-}2.0%) in the lateral ...

1997-12-01

68

Injuries of the tibio-talar joint and preoperative planning. Verletzungen des oberen Sprunggelenks aus unfallchirurgischer Sicht  

Energy Technology Data Exchange (ETDEWEB)

The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with ...

1991-12-01

69

Medical treatment of nystagmus and ocular motor disorders.  

Science.gov (United States)

An increased compendium of drugs useful in ocular motor system dysfunction has expanded our capacity to treat selected ocular motility disorders. Adjunctive therapeutic modes (e.g., Fresnel prisms and orthoptic exercises) can also be beneficial. PAN and see-saw nystagmus can be treated with baclofen. Downbeat nystagmus may respond to clonazepam therapy, and prisms may help if the nystagmus can be modified with convergence. Congenital nystagmus may respond minimally to drugs (e.g., baclofen), but prisms or surgical procedures, or both, are still the primary treatment modalities. Innovar may be helpful in patients with severe, incapacitating vestibular disorders, and scopolamine alone or in combination with promethazine may be beneficial in patients with milder ambulatory acute peripheral vestibular disorders. Benign positional vertigo is best treated initially with positional exercises before drug therapy is instituted. Opsoclonus and ocular flutter have been treated successfully with ...

1986-01-01

70

Measurement results of BHTV logging at the geothermal well. 1; Chinetsusei ni okeru BHTV kenso no sokutei kekka. 1  

Energy Technology Data Exchange (ETDEWEB)

In association with excavation of the No. 135 steam producing well in the Onikubi geothermal power plant in Miyagi Prefecture, shapes of production zones and drilling-induced fracture (DIF) were acquired from the borehole televiewer (BHTV) data. The BHTV logging shoots sound waves onto well walls of wells filled with fluid and detects the reflection waves to investigate the state of the well walls. Vertical fracture with opening lengths from 2 to 3 m were found at depths of about 1232 m and 1312 m. Water run-off has occurred at a depth of about 1312 m during the excavation, to which these vertical fractures might have contributed possibly. In depths of about 1232 m and 1312 m, fractures inclining toward north-east direction and south-west direction are predominant. Some fractures in the depth of about 1333 m incline toward east-south-east direction and west-north-west direction. Fracture inclination azimuth in all of the present logging sections is predominantly in north-east direction ...

1997-05-27

71

Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria  

Energy Technology Data Exchange (ETDEWEB)

In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26 mGy to 21.26 mGy for the mediolateral oblique (MLO) views and 0.08 mGy to 5.36 mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07 mGy to 3.57 mGy for the MLO views and 0.02 mGy to 0.98 mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients' data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean ESD values and MGD values reported in this work are below published values. The mean of the calculated MGD values is also found to be lower than the recommended ...

2009-11-15

72

Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria  

International Nuclear Information System (INIS)

In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26 mGy to 21.26 mGy for the mediolateral oblique (MLO) views and 0.08 mGy to 5.36 mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07 mGy to 3.57 mGy for the MLO views and 0.02 mGy to 0.98 mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients' data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean ESD values and MGD values reported in this work are below published values. The mean of the calculated MGD values is also found to be lower than the recommended guidance ...

2009-11-01

73

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous duct system, the Cooper ligaments and the ...

2009-07-21

74

Assessment of left ventricular wall motion by optional multiple long-axial gated blood pool SPECT  

International Nuclear Information System (INIS)

Optional multiple long-axial gated blood pool SPECT images were prepared for the purpose of stereoscopic and quantitative imaging of left ventricular wall motion (LVWM). Sixteen patients with ischemic heart disease and 8 healthy subjects were imaged in 32 views in the 360 degrees position after iv injection of 740 MBq of Tc-99m-labeled human serum albumin D. The R-R interval was divided into 16. After preparing conventional oblique images, long-axial images were prepared. Shortening rate of left ventricular wall was calculated in 5 segments of the apex and base of the left ventricle. An average shortening rate in each segment was graded with a score from a minimum of 0 to a maximum of 40% or more. In the normal group, shortening rate in each segment, except for the base of the septal region, exceeded 40%. In the group of ischemic heart disease, radial shortening was capable of visualizing the degree and extent of the whole LVWM abnormality. LVWM abnormality seen on ...

1991-01-01

75

An innovative apparatus provided with a cutting auger for producing short logs for biomass energy from fast-growing tree species  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a new cutting mechanism that cuts fresh wood into small pieces instead of wood chips in order to avoid the problem of fermentation that occurs in storage. The prototype cutting device performs a gradual and oblique cut. It consists of a large auger in which a knife is inserted on the outer edge of the helicoid. Tree trunks up to 20 cm in diameter are fed perpendicularly into the machine and are pushed along the axis where slices are cut off against a fixed sharp-edged counter blade. The cylinder enclosing the auger is the main frame of the machine, and is closed at one end, where a heavy flywheel delivers the energy coming from the tractor's power take-off (PTO). The wood pieces ranging in length from 4 to 19 cm exit through the opposite end. The auger is 700 mm in diameter with a 300 mm pitch spacing. The logs are pushed into the machine by counter-rotating rollers placed in the feed funnel. Tests were conducted to determine the ...

2010-07-01

76

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used to measure depth ...

77

Characterization of an add-on multileaf collimator for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the isocentre through ...

2008-02-21

78

Anatomic and radiologic correlations in spontaneous hematomas of the rectus abdomninis muscles; Correlazioni anatomo-radiologiche negli ematomi spontanei dei muscoli retti dell'addome  

Energy Technology Data Exchange (ETDEWEB)

Rectus sheath hematomas are a frequent but sometimes misdiagnosed disease in patients under anticoagulative drugs, hemodialysis, or simply in the elderly. The most frequent localization is in the lower part of the abdomen: the explanation lies in the anatomy of the abdominal wall, especially in the arcuate line of the rectus sheath. Aim of this work is to explain the reason of the almost constant location correlating the anatomy with the CT features. The rectus abdominis muscle lies between the aponeuroses of the transverse and oblique muscles which form the so called rectus sheath. This arrangement is found from the costal arch to a level approximately between the umbilicus and the pubic symphisis, where the rear layer of the rectus sheath ends with a curved edge, called the arcuate or semicircular line of Douglas. Beneath this line the aponeuroses of the three muscles pass in front of the rectus which is separated from the peritoneum only by the fascia ...

2000-06-01