WorldWideScience
1

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

2

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

3

Histopathological Image Analysis: A Review  

UK PubMed Central (United Kingdom)

Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available

2009-01-01

4

Knowledge-based image analysis: some aspects on the analysis of images using other types of information  

Energy Technology Data Exchange (ETDEWEB)

The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.

1982-01-01

7

Image-enhancement applications at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.

1982-06-01

8

SPARSE SUPERPIXEL UNMIXING FOR EXPLORATORY - NASA  

Science.gov (United States)

Fast automated analysis of hyperspectral imagery can inform ... hyperspectral image analysis. .... atmospheric correction with the Crism Analysis Tool [11]. ...

9

The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries  

UK PubMed Central (United Kingdom)

The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available

2010-01-01

10

A Software System for Data Analysis in Automated DNA?Sequencing  

UK PubMed Central (United Kingdom)

Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available

1998-06-01

11

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

13

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which ...

14

Utilization of consistency metrics for error analysis in deformable image registration  

UK PubMed Central (United Kingdom)

PurposeTo investigate the utility of consistency metrics, such as inverse consistency, in contour based deformable registration error analysis.Full Text Available

2009-09-21

15

Report of the Geostatistical Analysis of High Resolution ...  

Science.gov (United States)

... The variogram analysis of the high resolution imagery has shown that although more spatial scales have been identified than from the SPOT image ...

1998-05-01

16

Computer vision approaches to medical image analysis. Revised papers  

Energy Technology Data Exchange (ETDEWEB)

This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)

2006-07-01

17

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

18

Volume 2- Technical Approach - IMAGE Science Center - NASA  

Science.gov (United States)

Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...

19

RAPID DAMAGE ASSESSMENT FROM HIGH RESOLUTION IMAGERY  

Energy Technology Data Exchange (ETDEWEB)

Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.

2008-07-01

20

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

21

Radon concentration measurements by means of nuclear tracks detector with image analysis  

International Nuclear Information System (INIS)

English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,

1998-09-15

22

Evaluation of Peripheral Atherosclerosis: A Comparative Analysis of Angiography and Intravascular Ultrasound  

UK PubMed Central (United Kingdom)

ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available

2010-04-01

23

Proceedings: Image Understanding Workshop  

Energy Technology Data Exchange (ETDEWEB)

Sponsored by the Defense Advanced Research Projects Agency the Image Understanding Workshop is a forum for the presentation of new research in vision, image analysis, and geometric modeling. Leading scientists present overviews of projects underway at major universities and corporate research sites, as well as results of individual work. The 1987 volume contains 94 articles and technical reports in two volumes.

1987-01-01

24

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

25

Combined migration velocity model-building and its application in tunnel seismic prediction  

Science.gov (United States)

We propose a combined migration velocity analysis and imaging method based on Kirchhoff integral migration and reverse time migration, using the residual curvature analysis and layer stripping strategy to build the velocity model. This method improves the image resolution of Kirchhoff integral migration and reduces the computations of the reverse time migration. It combines the advantages of efficiency and accuracy of the two migration methods. Its application in tunnel seismic prediction shows good results. Numerical experiments show that the imaging results of reverse time migration are better than the imaging results of Kirchhoff integral migration in many aspects of tunnel prediction. Field data show that this method has efficient computations and can establish a reasonable velocity model and a high quality imaging section. Combination ...

2010-09-01

26

A comparison with result of normalized image to different template image on statistical parametric mapping of ADHD children patients  

Energy Technology Data Exchange (ETDEWEB)

We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.

2003-06-15

27

Parallel architecture for rapid image generation and analysis  

Energy Technology Data Exchange (ETDEWEB)

A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...

1987-01-01

28

Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...

2009-01-01

29

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

30

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were ...

1991-12-01

31

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and ...

1991-01-01

32

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

33

Monitoring the movement of water influx subsidence in coal district by remote sensing - examples from Huainan coal district  

Energy Technology Data Exchange (ETDEWEB)

Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.

2002-08-01

34

From a set of parts to an indivisible whole. Part II: Operations in an open comparative mode  

CERN Document Server

This paper describes a new method, HGV2C, for pattern analysis. The HGV2C method involves the construction of a computer ego (CE) based on an individual object that can be either a part of the system under analysis or a newly created object based on a certain hypothesis. The CE provides a capability to analyze data from a specific standpoint, e.g. from a viewpoint of a certain object. The CE is constructed from two identical copies of a query object, and its functioning mechanism involves: a hypothesis-parameter (HP) and infothyristor (IT). HP is a parameter that is introduced into an existing set of parameters. The HP value for one of the clones of a query object is set to equal 1, whereas for another clone it is greater than 1. The IT is based on the previously described algorithm of iterative averaging and performs three functions: 1) computation of a similarity matrix for the group of three objects ...

2008-01-01

35

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...

1982-06-01

36

Electrical biasing and voltage contrast imaging in a focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, ...

1995-09-01

37

Groundtruth approach to accurate quantitation of fluorescence microarrays  

Energy Technology Data Exchange (ETDEWEB)

To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images ...

2000-12-01

38

Image analysis of complex microstructures by texture analysis and correlation with properties by neural networks; Bildanalyse komplexer Werkstoffgefuege durch Texturanalyse und Korrelation mit den Eigenschaften durch neuronale Netze  

Energy Technology Data Exchange (ETDEWEB)

By characterising the microstructure, quantitative image analysis allows to draw conclusions on the mechanical properties of materials. On fine microstructures with low contrast, e.g. of hardened steels, texture analysis has to be applied for quantification. Feeding texture parameters according to Haralick into a trained neural network, a correlation between the microstructure and the hardness of the steels C45 and 100Cr6 can be achieved. (orig.)

2001-08-01

39

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, ...

1993-12-01

40

Computer vision algorithms in DNA ploidy image analysis  

Science.gov (United States)

The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent ...

2006-03-01

41

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...

2005-10-01

42

Oral Exposure to Bisphenol A Increases Dimethylbenzanthracene-Induced Mammary Cancer in Rats  

UK PubMed Central (United Kingdom)

BackgroundBisphenol A (BPA) is widely used in the manufacture of polycarbonate plastics, including infant formula bottles.ObjectivesBased on the...Full Text Available

2009-06-01

43

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided ...

1989-08-01

44

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided ...

1989-01-01

45

Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering  

Energy Technology Data Exchange (ETDEWEB)

In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)

2005-07-01

46

Study of technetium chemistry. Pt.10: Qsar analysis of "9"9Tc"m-labelled N_2S_2 analogues of brain imaging agents  

International Nuclear Information System (INIS)

Quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and structure parameters, for example lipophilicity F_r, molar refractivity MR and electronic parameters #sigma#_1 of the "9"9Tc"m-N_2S_2 complexes have been studied with multiple regression analysis method. The main structural factors which affect the initial brain uptake of this kind of brain imaging agents have been discussed. The results may give some theoretical information for designing new brain imaging agents

1998-02-01

47

Using ERS-2 SAR images for routine observation of marine pollution in European coastal waters  

Energy Technology Data Exchange (ETDEWEB)

More than 660 synthetic aperture radar (SAR) images acquired over the southern Baltic Sea, the North Sea, and the Gulf of Lyon in the Mediterranean Sea by the Second European Remote Sensing Satellite (ERS-2) have been analyzed since December 1996 with respect to radar signatures of marine pollution and other phenomena causing similar signatures. First results of our analysis reveal that the seas are most polluted along the main shipping routes. SAR images acquired during descending (morning) and ascending (evening) satellite passes show different percentages of oil pollution, because most of this pollution occurs during night time and is still visible on the SAR images acquired in the morning time. Moreover, we found a higher amount of oil spills on SAR images acquired during summer (April-September) than on SAR images acquired during winter (October-March). We ...

1999-09-30

48

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...

1987-12-01

49

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...

1987-01-01

50

MTF analysis of the near-real time neutron radiography facility at MURR  

International Nuclear Information System (INIS)

Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).

1981-12-01

51

Vibration signature analysis of AFM images  

Energy Technology Data Exchange (ETDEWEB)

Vibration signature analysis has been commonly used for the machine condition monitoring and the control of errors. However, it has been rarely employed for the analysis of the precision instruments such as an atomic force microscope (AFM). In this work, an AFM was used to collect vibration data from a sample positioning stage under different suspension and support conditions. Certain structural characteristics of the sample positioning stage show up as a result of the vibration signature analysis of the surface height images measured using an AFM. It is important to understand these vibration characteristics in order to reduce vibrational uncertainty, improve the damping and structural design, and to eliminate the imaging imperfections. The choice of method applied for vibration analysis may affect the results. Two methods, the data dependent systems (DDS) ...

1995-12-31

52

Statistical mapping analysis of serotonin synthesis images generated in healthy volunteers using positron-emission tomography and alpha-[11C]methyl-L-tryptophan.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To assess the suitability of analyzing functional images of brain serotonin (5-HT) synthesis with statistical parametric mapping (SPM), and to investigate further possible sex-related regional...Full Text Available

2000-09-01

53

Diagnostic imaging of the acutely injured patient  

Energy Technology Data Exchange (ETDEWEB)

This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.

1985-01-01

54

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI ...

2010-11-21

55

Teaching electron diffraction and imaging of macromolecules.  

UK PubMed Central (United Kingdom)

Electron microscopic analysis can be used to determine the three-dimensional structures of macromolecules at resolutions ranging between 3 and 30 A. It differs from nuclear magnetic resonance spectroscopy...Full Text Available

1993-05-01

56

Systems-level analysis of microbial community organization through combinatorial labeling and spectral imaging  

UK PubMed Central (United Kingdom)

Microbes in nature frequently function as members of complex multitaxon communities, but the structural organization of these communities at the micrometer level is poorly understood because of limitations...Full Text Available

2011-03-08

57

New retinal imaging for the visualization and analysis of vitreoretinal interface (VRI) by short-wavelength scanning laser ophthalmoscope (swSLO)  

UK PubMed Central (United Kingdom)

Background:The purpose of the study was to evaluate vitreoretinal interface (VRI) alteration with a short-wavelength scanning laser ophthalmoscope (swSLO), the Nidek F-10, and compare...Full Text Available

2011-01-01

58

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

59

Bone Quality determined by Fourier Transform Infrared Imaging Analysis in Mild Primary Hyperparathyroidism  

UK PubMed Central (United Kingdom)

Context: Mild primary hyperparathyroidism (PHPT) is characterized by asymptomatic hypercalcemia, most commonly in the absence of classical signs and symptoms. Hence, there is need to characterize...Full Text Available

2008-09-01

60

An Evaluation of Cellular Neural Networks for the Automatic Identification of Cephalometric Landmarks on Digital Images  

UK PubMed Central (United Kingdom)

Several efforts have been made to completely automate cephalometric analysis by automatic landmark search. However, accuracy obtained was worse than manual identification in every study. The analogue-to-digital...Full Text Available

2009-01-01

61

A new method for 2D gel spot alignment: application to the analysis of large sample sets in clinical proteomics  

UK PubMed Central (United Kingdom)

BackgroundIn current comparative proteomics studies, the large number of images generated by 2D gels is currently compared using spot matching algorithms. Unfortunately, differences...Full Text Available

62

Multidate image analysis of forest degradation in equatorial Africa  

Energy Technology Data Exchange (ETDEWEB)

A section of the northern margin of the Guineo-Congolian rain forest of the Central African Republic is studied to determine to what extent deforestation is evolving. Three sites are presented to highlight the diversity in local environmental settings at the northern margin of the closed equatorial rain forest: the contiguous equatorial rain forest, the boundary between the closed rain forest and the grasslands, and a predominantly secondary grassland environment. Proven image processing procedures for determining land cover and vegetation vigor were applied to Landsat MSS data to determine land cover characteristics and identify alterations in land cover that indicate potentially degraded forest environments. Land cover was independently assessed using spectral signatures determined from a statistical clustering routine. The images presented and image analyses contribute insights and information to an ongoing effort to ...

1990-12-01

63

Environmental, scanning electron and optical microscope image analysis software for determining volume and occupied area of solid-state fermentation fungal cultures  

British Library Electronic Table of Contents (United Kingdom)

Abstract Here we propose a software for the estimation of the occupied area and volume of fungal cultures. This software was developed using a Matlab platform and allows analysis of high-definition images from optical, electronic or atomic force microscopes. In a first step, a single hypha grown on potato dextrose agar was monitored using optical microscopy to estimate the change in occupied area and volume. Weight measurements were carried out to compare them with the estimated volume, revealing a slight difference of less than 1.5%. Similarly, samples from two different solid-state fermentation cultures were analyzed using images from a scanning electron microscope (SEM) and an environmental SEM (ESEM). Occupied area and volume were calculated for both samples, and the results obtained w...

2011-01-01

64

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In ...

1995-08-01

65

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the ...

1995-01-01

66

[sup 123]I-MIBG myocardial scintigraphy in diabetic patients. Relationship with [sup 201]Tl uptake and cardiac autonomic function  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to investigate the influence of diabetic myocardial damage (suspected myocardial damage; SMD) diagnosed by [sup 201]Tl-SPECT and diabetic cardiac autonomic neuropathy (AN) on myocardial MIBG uptake in patients with NIDDM. Eighty-seven diabetic patients divided into four subgroups: 23 with SMD (+) AN (+); 19 with SMD (+) AN (-); 27 with SMD (-) AN (+); 18 with SMD (-) AN (-), and 10 controls were studied. Both planar and SPECT images were taken at 30 minutes (early) and 3 hours (delayed) after [sup 123]I-MIBG injection. The heart to mediastinum uptake ratio (H/M) and washout ratio of [sup 123]I-MIBG (WR) were obtained from both planar images. Similarly, the difference between the [sup 201]Tl image and the [sup 123]I-MIBG image in the total uptake score (TUS) was taken as the difference in the total uptake score ([Delta]TUS) representing cardiac sympathetic denervation without ...

1998-12-01

67

MR evaluation of rectal carcinoma: pelvic phased-array coil versus endorectal-pelvic phased-array coil  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader ...

1998-10-01

69

Measurements of nuclear emulsion tracks by means of a picture analysis system  

Energy Technology Data Exchange (ETDEWEB)

A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.

1986-01-01

70

Automated analysis of damages for radiation in plastics surfaces; Analisis automatizado de danos por radiacion en superficies plasticas  

Energy Technology Data Exchange (ETDEWEB)

Analysis of damages done by the radiation in a polymer characterized by optic properties of polished surfaces, of uniformity and chemical resistance that the acrylic; resistant until the 150 centigrade grades of temperature, and with an approximate weight of half of the glass. An objective of this work is the development of a method that analyze in automated form the superficial damages induced by radiation in plastic materials means an images analyst. (Author)

1990-02-15

71

Synthetic aperture radar image of agricultural fields with surface drainage network: simulation and spatial information retreival  

Science.gov (United States)

We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR images of undulated vegetation medium. Validation of simulations made with actual SAR images shows that ...

2001-10-01

72

Imaging of salt structure; Gan`enso kozo no imaging  

Energy Technology Data Exchange (ETDEWEB)

Due to the improvement of algorithm and the advancement of calculation performance, the imaging by depth migration before stacking is being put into practice from the viewpoint of both calculation cost and accuracy. A lot of imaging examples have been already reported from the survey areas with complicated velocity structures, such as the North Sea and the Gulf of Mexico. Effectiveness of the method has been confirmed. For imaging techniques in Japan National Oil Corporation and Japan Petroleum Exploration Co., Ltd., high-speed depth migration before stacking and high efficiency velocity structure estimation technique have been investigated. This paper describes necessary care to be taken when using depth focusing analysis (DFA) for correcting a velocity model, as an interim stage of case study. The results of depth migration before stacking using dip moveout (DMO) velocity were further inferior to the ...

1996-10-01

73

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed ...

2002-04-01

74

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed ...

2002-04-01

75

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...

1991-11-01

76

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...

1991-01-01

77

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The ...

2009-03-15

78

High resolution transmission electron microscopy of partial states of oxygen order in YBa_2Cu_3O_z  

International Nuclear Information System (INIS)

This paper reports on high resolution electron microscopy used to investigate the effect of electron irradiation induced oxygen loss on the states of partial order in YBa_2Cu_3O_z. Contrast effects visible in the [001] zone image as a result of the degree of the out-of-plane correlation of these ordered states are investigated. Using statistical simulations to aid in the analysis of the HREM images, an interpretation based on a kinetically limited evolution of the variation of long range [001] ordering is proposed.

1990-04-16

79

SAR of Cu (II) Thiosemicarbazone Complexes as Hypoxic Imaging Agents: MM3 Analysis and Prediction of Biologic Properties  

British Library Electronic Table of Contents (United Kingdom)

Abstract Copper(II) bis(thiosemicarbazone) are very useful for blood flow and hypoxic imaging. The aim of this study was to identify structure-activity relationships (SARs) within a series of analogues with different substitution patterns in the ligands, in order to design improved hypoxia imaging agents and elucidate hypoxia selectivity mechanisms. Genetic algorithms (GAs) were used to develop specific copper metal-ligand force field parameters for the MM3 force-field calculations. These new parameters produced results in good agreement with experiment and previously reported copper metal-ligand parameters. A successful quantitative SAR (QSAR) for predicting the several classes of Cu(II)-chelating ligands was built using a training set of 21 Cu(II) complexes. The QSAR exhibited a correlat...

2010-01-01

80

Remote sensing analysis of rainstorm effects on sediment concentrations in Apalachicola Bay, USA  

British Library Electronic Table of Contents (United Kingdom)

Remote sensing of total suspended solids (TSS) by satellite techniques in estuaries and bays plays an important role in monitoring water quality over a large area. It is valuable to the management of coastal water environment and ecosystems. In this study, remote sensing mapping of TSS was conducted to investigate the effects of rainstorm events on Apalachicola Bay. A rainstorm event (October 7-8, 2008) was selected for a period when wind speeds were weak and the river inflow was almost steady. TSS mapping of MODIS images before and after the rainstorm event showed substantial increase of TSS induced by the rainstorm. Using an image during low river discharge before the rainstorm as a reference, TSS distribution was mapped by an improved regression model using MODIS image after a rainstorm...

2011-01-01

81

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

82

New pulse sequence for simultaneous T1, T2, and RHO determination in whole-body proton MR imaging  

International Nuclear Information System (INIS)

A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.

83

Dynamic and static error analyses of neutron radiography testing  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is separate from the static ...

1999-03-01

84

The use of lead isotopic abundances in trace uranium samples for nuclear forensics analysis  

International Nuclear Information System (INIS)

Secondary ion mass spectrometry (SIMS), secondary electron microscopy (SEM) and X-ray analysis have been applied to the measurement of U-bearing particles with the intent of gleaning information concerning their history and/or origin. The lead isotopic abundances are definitive indicators that U-bearing particles have come from an ore-body, even if they have undergone chemical processing. SEM images and X-ray analysis can add further information to the study that may allude to the extent of chemical processing. The presence of 'common' lead that does not exhibit a radiogenic signature is clear evidence of anthropogenic origin. (author)

2010-06-01

85

Pixel-based and object-oriented change detection analysis using high-resolution imagery  

Energy Technology Data Exchange (ETDEWEB)

The high spatial resolution of state-of-the-art commercial satellite imagery provides a good basis for recognising and monitoring even small-scale structural changes within nuclear facilities and for planning of routine and/or challenge inspections of nuclear sites. Despite the advantages of the improved spatial resolution some problems exist that may make the interpretation of the changes more difficult: Firstly, the results of the change analysis can be very complex and unclear at a glance. Secondly, shadow formation and off-nadir images due to different sensor and solar conditions at the acquisition times can cause false signals or overlap real changes. In view to the fast-growing amount of data from different sensor types there are then some requirements of an effective change detection procedure for safeguards purposes: i. The techniques involved should possess a certain amount of robustness in terms of small misregistration errors, ...

2003-05-01

86

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

87

Analysis of degradation in nickel-based alloys using focused ion beam imaging and specimen preparation combined with analytical electron microscopy  

International Nuclear Information System (INIS)

Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to ...

2002-09-23

88

Computer image analysis of wear debris for machine condition monitoring and fault diagnosis  

Energy Technology Data Exchange (ETDEWEB)

Whenever moving surfaces interact, wear particles are produced. Microscopic examination of the morphology of such wear debris is an accepted method for machine condition monitoring and fault diagnosis. Wear particle analysis has not, however, been widely accepted in industry because it is dependent on expert interpretation of particle morphology and relies on subjective assessment criteria. Consequently, the methods are time consuming and expensive and are not always consistent. The use of automated computer image analysis systems to assess the morphology of debris promises to overcome these limitations by making the methods more time and cost efficient, and also more consistent and effective. The first step required for automation of the analysis procedure is to develop objective criteria for assessing the wear particle morphology. Numerical parameters to describe the morphology have been developed and ...

1995-03-01

89

Structures in the Universe and Origin of Galaxies  

CERN Document Server

The analysis of images (of obtained in various ranges of the lengths of waves) of luminous objects in the Universe by means of a method of multilevel dynamic contrasting led author to the conclusions: a) the structures of all observable galaxies represents a complicated constructions which have the tendency to self-similarity and made of separate (basic) blocks, which are a coaxially tubular structures and a cartwheel-like structures; b) the majority of observable objects in the Universe are luminous butt-ends of almost invisible (of almost completely transparent) of filamentary formations which structures are seen only near to their luminous butt-ends; c) the result of analysis of images of cosmic objects show the structure of many pairs of cooperating galaxies point to opportunity of their formation at butt-ends generated in a place of break of the similar filament; d) the interacting galaxies (M 81 ...

2005-01-01

90

International Lens Design Conference, Monterey, CA, June 11-14, 1990, Proceedings  

Energy Technology Data Exchange (ETDEWEB)

The present conference on lens design encompasses physical and geometrical optics, diffractive optics, the optimization of optical design, software packages, ray tracing, the use of artificial intelligence, the achromatization of materials, zoom optics, microoptics and GRIN lenses, and IR lens design. Specific issues addressed include diffraction-performance calculations in lens design, the optimization of the optical transfer function, a rank-down method for automatic lens design, applications of quadric surfaces, the correction of aberrations by using HOEs in UV and visible imaging systems, and an all-refractive telescope for intersatellite communications. Also addressed are automation techniques for optics manufacturing, all-reflective phased-array imaging telescopes, the thermal aberration analysis of a Nd:YAG laser, the analysis of illumination systems, athermalized FLIR optics, and the design of ...

1990-01-01

91

Estimating hip fracture risk from digital x-ray image data  

International Nuclear Information System (INIS)

The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone ...

92

Analysis of the changes of vegetation coverage of western Beijing mountainous areas using remote sensing and GIS  

British Library Electronic Table of Contents (United Kingdom)

Mentougou District acts as a crucial component in the ecological buffer in western Beijing mountainous areas, Beijing, China. Using two Landsat MSS/TM images acquired on July 14, 1979 and July 23, 2005, the vegetation coverage of Mentougou District was calculated based on normalized difference vegetation index and spectral mixture analysis (NDVI-SMA) model. Its temporal and spatial changes were analyzed according to digital elevation model (DEM) image, social and economic data. The results showed that the vegetation coverage decreased from 76.4% in 1979 to 72.7% in 2005. Vegetation degradation was probably the result of human disturbance, such as outspreading of resident areas, and coal and stone mining activities, while vegetation restoration might be contributed by the combined effects o...

2009-01-01

93

Amplitude preserved VSP reverse time migration for angle-domain CIGs extraction  

Science.gov (United States)

An improved method of generating angle-domain common-image gathers (ADCIGs) by VSP reverse time migration (RTM) is introduced in this paper. The formula which is used to compute the receiver wavefield for VSP RTM is modified by adding an amplitude correction term in order to conveniently output amplitude-preserved ADCIGs. Compared with the surface seismic data, VSP data contains much richer wavefields. However, the direct and downgoing waves can bring about serious imaging artifacts in ADCIGs, especially the direct wave. The feasibility and validity of this method is demonstrated by both numerical and real VSP data from western China. Thus, the ADCIGs from this method can provide reliable basic data for VSP migration velocity analysis, VSP AVO/AVA analysis, and inversion.

2011-06-01

94

Analysis and Assessment of Land Use Change in Alexandria, Egypt Using Satellite Images, GIS, and Modelling Techniques  

International Nuclear Information System (INIS)

Alexandria is the second largest urban governorate in Egypt and has seen significant urban growth in its modern and contemporary history. This study investigates the urban growth phenomenon in Alexandria, Egypt, using the integration of remote sensing and GIS. The urban physical expansion and change were detected using Landsat satellite images. The satellite images of years 1984 and 1993 were first geo referenced, achieving a very small RMSE that provided high accuracy data for satellite image analysis. Then, the images were classified using a tailored classification scheme with accuracy of 93.82% and 95.27% for 1984 and 1993 images respectively. This high accuracy enabled detecting land use/land cover changes with high confidence using a post-classification comparison method. One of the most important findings here is the loss of cultivated land in favour of ...

95

Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience  

International Nuclear Information System (INIS)

Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the ...

2009-09-01

96

Visualization and measurement of heat transfer phenomenon  

Energy Technology Data Exchange (ETDEWEB)

This research aims at elucidating thermal hydraulic phenomena by carrying out their visualization and measurement which are difficult by conventional method, utilizing the excellent properties of real time neutron radiography and showing the usefulness of neutron radiography. The experiments were carried out on the visualization and measurement of liquid metal flow and mixed phase flow and the visualization and diagnosis of mixed phase flow equipment. As the achievement in this fiscal year, the image-processing method for visualizing quantitatively the distribution of void fraction in gas-liquid two-phase flow has been devised, therefore, its method and results are reported. For the analysis of multi-dimensional two-phase flow, in order to prepare the model and determine the constitution equation, the data on the multi-dimensional distribution of void fraction are required. Void fraction is defined. The method of image ...

1995-03-01

97

Soft tissue manifestations of early rheumatic disease. Imaging with MRI  

International Nuclear Information System (INIS)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). ...

2006-08-01

98

MTF analysis of the MURR real-time neutron radiography facility  

International Nuclear Information System (INIS)

In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate ...

1982-04-01

99

Cyst-like cortical tubers in patients with tuberous sclerosis complex: MR imaging with the FLAIR sequence  

Energy Technology Data Exchange (ETDEWEB)

Tuberous sclerosis complex (TSC) is an inherited disorder characterized by the presence of cortical tubers, the majority of which are solid and show high signal on FLAIR images. Low-signal tubers are less frequent. To evaluate cystic cortical tubers in patients with TSC on the basis of their appearance on FLAIR images. MR examinations of 73 patients were retrospectively reviewed and 17 children (aged 25 days to 12.3 years) with a typical cyst-like tubers were selected for further analysis. The age of the patients, the number of lesions, and the shape and MR intensity were analyzed. Cyst-like cortical tubers were detected in 82% of children below 7 years of age and in 18% of those older then 7 years (P=0.00086). Most of the cystic lesions were of the shrunken type (72%), the expansile type being less frequently seen (28%). FLAIR images confirm the cystic character of some of the cortical tubers in TSC ...

2006-06-15

100

Cavity detection based on EM migration of TEM data; TEM ho data no denji migration ni yoru kudo kenshutsu no kokoromi  

Energy Technology Data Exchange (ETDEWEB)

With an objective to discuss applicability of resistivity imaging using electromagnetic migration to detection of underground cavity, an applicability test was carried out on calculation of a numerical model and measurement data. By using the numerical model, a calculation was performed on a hypothetical case that a cubic cavity with sides each at 40 m exists in a homogenous medium of 200 ohm-m, with the cavity top located 20 m below the ground surface. As a result, it was possible to structure in a very short calculation time an image of the cavity which cannot be identified by one-dimensional inverse analysis. In the case of this cavity, a center of the image was structured on its lower face. It was shown that a location to indicate the image must be changed according to difference in the measurement locations. In a test on data measured in an underground cavity in the city of ...

1997-05-27

101

Brain development during the first year of life. Quantitative assessment with ADC imaging  

International Nuclear Information System (INIS)

Brain development during the first year of life was assessed quantitatively using apparent diffusion coefficient (ADC) images constructed from diffusion-weighted MR image data. The imaging plane was coronal at the section of the pons. The cerebral peduncle, internal capsule, corona radiata, superior longitudinal fasciculus and thalamus were selected for evaluation of their ADC values. A diffusion sensitive gradient was added in the anteroposterior direction. Thus the orientation of nerve fibers in the cerebral peduncle, internal capsule and corona radiata was perpendicular to it, and that in the superior longitudinal fasciculus was parallel to it. In neonates, the cerebral peduncle and internal capsule, having been moderately myelinated at birth, showed the slowest diffusion. The corona radiata and superior longitudinal fasciculus, having been unmyelinated at birth, showed the fastest diffusion. The thalamus had ...

102

Airbags to Martian Landers: Analyses at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

A new direction for the national laboratories is to assist US business with research and development, primarily through cooperative research and development agreements (CRADAs). Technology transfer to the private sector has been very successful as over 200 CRADAs are in place at Sandia. Because of these cooperative efforts, technology has evolved into some new areas not commonly associated with the former mission of the national laboratories. An example of this is the analysis of fabric structures. Explicit analyses and expertise in constructing parachutes led to the development of a next generation automobile airbag; which led to the construction, testing, and analysis of the Jet Propulsion Laboratory Mars Environmental Survey Lander; and finally led to the development of CAD based custom garment designs using 3D scanned images of the human body. The structural analysis of these fabric structures is ...

1994-03-01

103

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

104

Lagrangian analysis of contaminant dispersal in bounded turbulent shear flows  

Energy Technology Data Exchange (ETDEWEB)

Methods of solving Navier-Stokes equations for turbulent channel flow are given. These numerical solutions utilize either Neumann or Dirichlet boundary conditions. Computer codes were written and tested and are discussed. Digital image processing of flow visualization video sequences, taken simultaneously with vorticity probe measurements in a turbulent boundary layer, were carried out. 4 figs. (GHH)

1991-01-01

105

Optical Images Due to Lenses and Mirrors  

Science.gov (United States)

... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...

106
107

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

108

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work ...

2001-07-01

109

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one ...

2003-03-15

110

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one ...

2003-03-01

111

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.

2003-05-01

112

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

113

Quantitative 1-123 IMP SPECT, MR imaging, and neuropsychologic testing in AIDS dementia  

International Nuclear Information System (INIS)

The authors have performed I-123 IMP single- photon emission CT (SPECT) brain imaging on seven mildly demented patients with acquired immunodeficiency syndrome (AIDS) and on seven normal subjects. Pixel-intensity histograms have been analyzed for the fraction of pixels in the lowest quartile of the intensity range. This fraction (F) averaged 17.7% (standard deviation [SD] = 4.3) in the AIDS group and 12.6 (SD = 4.7) in the normal group (P <.05). Regression analysis of neuropsychological testing (NPT) scores vs F yielded a correlation coefficient of.71. The presence or degree of atrophy did not correlate with F or NPT scores.

114

Promoting medical tourism to India: Messages, images, and the marketing of international patient travel  

British Library Electronic Table of Contents (United Kingdom)

The practice of medical tourism depends on successfully informing potential patients about procedure options, treatment facilities, tourism opportunities, travel arrangements, and destination countries. The promotion of medical tourism includes a wide range of marketing materials such as flyers, booklets, and websites. Yet, there is a paucity of knowledge about the dissemination, content, and reception of these promotional materials. Drawing on a thematic content analysis of the promotional print material distributed at the first medical tourism trade show in Canada in 2009, the main purpose of this article is to identify and understand the messages and images that companies use to market India as a global destination. While researchers and news media frequently cite low cost procedures as...

2011-01-01

115

Magnetic resonanse imaging in otorhinolaryngology. With special reference to the influence of factors upon NMR parameters and differential diagnosis of otorhinolaryngic lesions  

Energy Technology Data Exchange (ETDEWEB)

MRI diagnosis for malignant tumors are made possible by direct comparison to the results obtained by the brain and it seems possible to differentiate malignant tumors from other benign lesions. Cystic lesions, and mycotic sinusitis sometimes resemble malignant tumors in MR Image. In the present report, we investigated the relationships between the biochemical contents of cystic lesions and NMR-parameters to clarify why some inflammatory lesions appeared similar to malignant tumors in MRI. The variation of relaxation time depends upon the amount of protein in the cystic contents and the amount of glucose affects the relaxation time. We conclude that NMR-parameters are useful for the differential diagnosis of malignant tumors, cystic lesions and mycositic sinusitis by using the multiple variation analysis.

1987-07-01

116

Investigation of the unsteadiness of a shock-reflection interaction with time-resolved particle image velocimetry  

British Library Electronic Table of Contents (United Kingdom)

The spatio-temporal dynamics of an impinging shock/boundary layer interaction at Mach 2 and under incipient separation conditions, has been investigated experimentally by means of high-speed particle image velocimetry (PIV). The available PIV acquisition rate of up to 20 kHz permits a time-resolved characterization of the interaction. The dynamics of different flow regions?notably the separation region and the reflected shock?were quantified by means of temporal auto-correlation fields and pseudo-spectral analysis. The PIV data further enable to investigate the relationship between spatially extended flow features, such as shock position and bubble size, as well as the influence of the upstream boundary layer. The results confirm earlier studies that there is an important upstream effect o...

2011-01-01

117

Images of addiction and recovery: An interpretative phenomenological analysis of the experience of addiction and recovery as expressed in visual images  

British Library Electronic Table of Contents (United Kingdom)

This article focuses on visual representations of subjective experiences of the process of recovery from addiction and the meanings that participants attribute to their visual work. The data are drawn from a study of six female participants. In this article, we discuss the results with reference to one participant, to allow for detailed consideration of the visual and the verbal material. This participant was selected because of the richness of her material, which provided an opportunity to carry out a detailed case study. Potential participants were informed in advance that they would be asked to draw during the interview. They were also asked to bring to the interview some artwork made during their engagement in creative activities at an earlier stage in their recovery. The data were ana...

2011-01-01

118

Evaluation of routine telephone transmission of nuclear medicine studies  

Energy Technology Data Exchange (ETDEWEB)

Rapid and reliable transmission of nuclear medicine studies using conventional telephone lines and commercially available modems and computer systems has been accomplished through use of software developed within the authors' hospital. Original digital images of all-night and weekend studies, acquired on any of the acquisition computers from different manufacturers, are now routinely sent for remote reading at the physician's home. Data, software, and letters are routinely exchanged using modems and standard telephone lines with a sister institution in Haifa, Israel. The software has been designed to achieve no loss data compression and minimal turnaround time loss. Thus, an average lung perfusion image or gallbladder study requires about 1-3 minutes of transmission time. Full analysis and display software is available on the remote computer.

1989-01-01

119

Electronic imaging system for neutron radiography at a low power research reactor  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-15

120

Electronic imaging system for neutron radiography at a low power research reactor  

International Nuclear Information System (INIS)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-01

121

Development of a petrographic technique for the quality control of concrete mixes used in mines. Final report; Mise au point d`une technique petrographique pour le controle de qualite des betons miniers. Rapport final  

Energy Technology Data Exchange (ETDEWEB)

Petrographical analysis is a microscopical analytical tool which allows definition of the exact nature of the components of different concrete mixes, as well as definition of internal structures and alteration processes. In order to improve the precision and the swiftness of the petrographical analysis, an automated image analysis system has been developed. In the next stage of this study, which consisted in the testing of new concrete mixes containing fluidised bed ashes, petrography has been used, not only to identify the nature of the mix components, but also assess the behaviour of these new concrete mixes when exposed to aggressive conditions.

1997-11-01

122

Automated three-dimensional X-ray analysis using a dual-beam FIB  

International Nuclear Information System (INIS)

We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.

2007-08-01

123

The NIR Upgrade to the SALT Robert Stobie Spectrograph  

CERN Document Server

The near infrared (NIR) upgrade to the Robert Stobie Spectrograph (RSS) on the Southern African Large Telescope (SALT), RSS/NIR, extends the spectral coverage of all modes of the visible arm. The RSS/NIR is a low to medium resolution spectrograph with broadband imaging, spectropolarimetric, and Fabry-Perot imaging capabilities. The visible and NIR arms can be used simultaneously to extend spectral coverage from approximately 3200 A to 1.6 um. Both arms utilize high efficiency volume phase holographic gratings via articulating gratings and cameras. The NIR camera is designed around a 2048x2048 HAWAII-2RG detector housed in a cryogenic dewar. The Epps optical design of the camera consists of 6 spherical elements, providing sub-pixel rms image sizes of 7.5 +/- 1.0 um over all wavelengths and field angles. The exact long wavelength cutoff is yet to be determined in a detailed thermal analysis and will ...

2006-01-01

124

Remote sensing monitoring method of hyperspectral and high-resolution for underground coal bed combustion  

Energy Technology Data Exchange (ETDEWEB)

Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface temperature retrieval model was ...

2007-10-15

125

Medical image transmission via communication satellite. Evaluation of bone scintigraphy  

International Nuclear Information System (INIS)

As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% via satellite, and ...

126

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR ...

1985-04-25

127

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC ...

1989-02-01

128

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

International Nuclear Information System (INIS)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC ...

1989-01-01

129

Bone scintigraphy in fluoride treated osteoporosis  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid ...

1985-05-01

132

Java Image I/O for VICAR, PDS, and ISIS  

Science.gov (United States)

This library, written in Java, supports input and output of images and metadata (labels) in the

2011-01-01

133

A multi-wavelength scattered light analysis of the dust grain population in the GG Tau circumbinary ring  

Energy Technology Data Exchange (ETDEWEB)

We present the first 3.8 {micro}m image of the dusty ring surrounding the young binary system GG Tau, obtained with the W. M. Keck II 10m telescope's adaptive optics system. THis is the longest wavelength at which the ring has been detected in scattered light so far, allowing a multi-wavelength analysis of the scattering proiperties of the dust grains present in this protoplanetary disk in combination with previous, shorter wavelengths, HST images. We find that the scattering phase function of the dust grains in the disk is only weakly dependent on the wavelength. This is inconsistent with dust models inferred from observations of the interstellar medium or dense molecular clouds. In particular, the strongly forward-throwing scattering phase function observed at 3.8 {micro}m implies a significant increase in the population of large ({approx}> 1 {micro}m) grains, which provides direct evidence for grain ...

2004-02-04

134

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression ...

2003-12-01

135

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression ...

2003-12-01

136

Imaging of reflection seismic and radar wavefields: Monitoring of steam-heated oil reservoirs and characterization of nuclear waste repositories  

Energy Technology Data Exchange (ETDEWEB)

A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the Cold Lake deposit. Simulations were performed during different phases of the steam stimulation process to examine the relation between reservoir properties and conditions ...

1994-12-31

137

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = ...

1997-01-01

138

Skeletal remodeling dynamics: New approaches with imaging instrumentation  

Energy Technology Data Exchange (ETDEWEB)

This report of progress and future objectives timetable is based on an included schematic of goals and objectives and the project abstract which is included as Appendix 1. Five matters are summarized in the order of (1) novel methods of calcified bone confocal microscopy and reconstruction image analysis of decalcified beagle and human cortical bone serial sections, (2) macroscopic cross-correlation of beagle and human cortical and cancellous bone fractions with CT analysis, (3) guidance to the most radiobiologically important skeletal regions of interest with the just completed {sup 90}Sr bone tumor map from life time beagle studies, (4) deposition patterns of radioactive agents that participate in apatite crystal nucleation processes in bone and leave radiation-excited electrons trapped in bone mineral, and (5) the budget period timetable. The discovery that beta particles from {sup 166}Ho (T{sub {1/2}} =26 hr, {beta}{sub ...

1991-12-01

139

Risk perception on management of nuclear high-level and transuranic waste storage  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy`s program for disposing of nuclear High-Level Waste (HLW) and transuranic (TRU) waste has been impeded by overwhelming political opposition fueled by public perceptions of actual risk. Analysis of these perceptions shows them to be deeply rooted in images of fear and dread that have been present since the discovery of radioactivity. The development and use of nuclear weapons linked these images to reality and the mishandling of radioactive waste from the nations military weapons facilities has contributed toward creating a state of distrust that cannot be erased quickly or easily. In addition, the analysis indicates that even the highly educated technical community is not well informed on the latest technology involved with nuclear HLW and TRU waste disposal. It is not surprising then, that the general public feels uncomfortable with DOE`s management plans for with nuclear HLW ...

1994-08-15

140

Evaluation of computer-aided detection of lesions in mammograms obtained with a digital phase-contrast mammography system  

Energy Technology Data Exchange (ETDEWEB)

A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach ...

2009-12-15

141

Die Backside FIB Preparation for Identification and Characterization of Metal Voids  

Energy Technology Data Exchange (ETDEWEB)

Both the increased complexity of integrated circuits, resulting in six or more levels of integration, and the increasing use of flip-chip packaging have driven the development of integrated circuit (IC) failure analysis tools that can be applied to the backside of the chip. Among these new approaches are focused ion beam (FIB) tools and processes for performing chip edits/repairs from the die backside. This paper describes the use of backside FIB for a failure analysis application rather than for chip repair. Specifically, they used FIB technology to prepare an IC for inspection of voided metal interconnects (lines) and vias. Conventional FIB milling was combined with a super-enhanced gas assisted milling process that uses XeF{sub 2} for rapid removal of large volumes of bulk silicon. This combined approach allowed removal of the TiW underlayer from a large number of Ml lines simultaneously, enabling rapid localization and plan view ...

1999-07-28

142

Analysis of the quantitative structure activity relationship of technetium-99m-labeled diaminedithiol (DADT) and propyleneamineoxime (PAO) brain blood flow analogues  

Energy Technology Data Exchange (ETDEWEB)

In the search for new brain imaging agents for use with single photon emission computed tomography (SPECT), quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and physicochemical parameters like lipophilicity, log P, molecular weight, log MW and log U/D (undissociated/dissociated), of the {sup 99m}Tc-DADT (diaminedithiol) complexes and {sup 99m}Tc-PAO (propyleneaminoxime) complexes have been analyzed. High correlations are found for both the {sup 99m}Tc-DADT complexes (r = 0.94) and for the {sup 99m}Tc-PAO complexes (r = 0.83) which are significant at 99.9 and 99.5 percentile level, respectively. These results will help the further design of better ligands for {sup 99m}Tc in brain imaging. (author).

1991-01-01

143

Implementation of the Random Forest method for the Imaging Atmospheric Cherenkov Telescope MAGIC  

Energy Technology Data Exchange (ETDEWEB)

The paper describes an application of the tree classification method Random Forest (RF), as used in the analysis of data from the ground-based gamma telescope MAGIC. In such telescopes, cosmic gamma-rays are observed and have to be discriminated against a dominating background of hadronic cosmic-ray particles. We describe the application of RF for this gamma/hadron separation. The RF method often shows superior performance in comparison with traditional semi-empirical techniques. Critical issues of the method and its implementation are discussed. An application of the RF method for estimation of a continuous parameter from related variables, rather than discrete classes, is also discussed.

2008-04-11

144

Fabrication of 10nm diameter carbon nanopores  

Energy Technology Data Exchange (ETDEWEB)

The addition of carbon to samples, during imaging, presents a barrier to accurate TEM analysis, the controlled deposition of hydrocarbons by a focused electron beam can be a useful technique for local nanometer-scale sculpting of material. Here we use hydrocarbon deposition to form nanopores from larger focused ion beam (FIB) holes in silicon nitride membranes. Using this method, we close 100-200nm diameter holes to diameters of 10nm and below, with deposition rates of 0.6nm per minute. I-V characteristics of electrolytic flow through these nanopores agree quantitatively with a one dimensional model at all examined salt concentrations.

2008-09-25

145

Analysis of brain CT on 120 patients of human cysticercosis  

International Nuclear Information System (INIS)

A study on brain CT was made in 120 patients of human cysticercosis, which is a rare disease in Japan and clinical symptoms and laboratory data for the diagnosis were also discussed. From the point of therapeutic view, we proposed a new differentiation on brain CT of human cysticercosis, which is divided into two groups according to the alve or dead parasite. Furthermore, we proposed a new type named multiple large and small cysts type on brain CT. The idea of diagnostic standard was made integrating brain CT image, clinical symptoms and labolatory data. (author).

146

Multitemporal analysis of satellite data and their use in the monitoring of the environmental impacts of open cast lignite mining areas in Eastern Germany  

Energy Technology Data Exchange (ETDEWEB)

The use and application of remote sensing data for monitoring the environmental impacts of open cast lignite mining in Eastern Germany is described. This investigation is based on the digital analysis of several Landsat-TM and ERS-1 data sets acquired from 1989 to 1994. The characteristics of the imagery enable quantitative analysis of different open cast mine features, such as waste, water bodies, change of land use, reclamation processes and estimation of vegetation cover in the affected areas. On the basis of the Maximum Likelihood Classification of Landsat Thematic Mapper (TM) data the open cast mining areas were separated into bare open cast areas and areas of less and dense vegetation. The bare open cast areas were classified with respect to type of different sediments and the vegetation was seperated into different classes according to the age of the vegetation and the density cover. Apart from these, water bodies within the mining areas ...

1998-08-01

147

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which ...

1998-05-01

148

Turbulent Flame Speed Characteristics Of High-Pressure, Lean Premixed Methane / Air Flames  

Energy Technology Data Exchange (ETDEWEB)

High-pressure, lean, premixed methane/air flames are investigated experimentally to determine turbulent flame speeds (s{sub T}). The results are based on the statistical analysis of single-shot OH-PLIF images. The influences of pressure (p = 5 - 14.4 bars) and equivalence ratio ( {phi} 0.43 - 0.56) on the turbulent flame speed are discussed. The analysis reveals that s{sub T} is independent of pressure and it depends strongly on equivalence ratio. The turbulent flame speed at {phi} = 0.56 is about 3 times higher than at {phi} = 0.43 because of the higher integral reaction rate caused by the higher fuel concentration and therefore higher adiabatic flame temperature. (author)

2005-03-01

149

Partial unmixing as a tool for single surface class detection and time series analysis  

British Library Electronic Table of Contents (United Kingdom)

In this paper we present the results of time series analysis for a coal mining region based on partial unmixing. We test the method also known as mixture tuned matched filtering on an eight image Landsat 5 TM and Landsat 7 ETM+ time series covering the period from 1987 to 2003. Common change detection methods often include the comparison of two interactively generated classification results, such as derived from Maximum Likelihood classification. These approaches often yield highly accurate results. However, disadvantages include a strong analyst bias and hardly repeatable results. For a quantitative monitoring of a single surface class' development over time they are often not recommendable. Our goal was to test an unbiased quantitative way to assess the development of coal surfaces, such...

2008-01-01

150

Outcomes and Cost Analysis of Pyeloplasty for Antenatally Diagnosed Ureteropelvic Junction Obstruction Using Markov Models  

British Library Electronic Table of Contents (United Kingdom)

Objectives The optimal timing of pyeloplasty for children diagnosed with ureteropelvic junction obstruction (UPJO) after workup for antenatal hydronephrosis is disputed. We sought to examine the potential costs and clinical outcomes of treatment protocols featuring different indications for pediatric pyeloplasty using Markov models. Methods Cost and outcomes analysis using Markov modeling was performed for three treatment algorithms: medical management, immediate pyeloplasty (during the first year of life), and pyeloplasty after no improvement on imaging. The costs were determined from the perspective of the medical institution. The variables tracked during Markov model simulation included age at resolution of UPJO, the proportion of patients with worsened hydronephrosis, the number of pye...

2008-01-01

151

Local thermal property analysis by scanning thermal microscopy of an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment  

International Nuclear Information System (INIS)

Scanning thermal microscopy (SThM) was used to map thermal conductivity images in an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment (SMAT). It is found that the deformed surface layer shows different thermal conductivities that strongly depend on the grain size of the microstructure: the thermal conductivity of the nanostructured surface layer decreases obviously when compared with that of the coarse-grained matrix of the sample. The role of the grain boundaries in thermal conduction is analyzed in correlation with the heat conduction mechanism in pure metal. A theoretical approach, based on this investigation, was used to calculate the heat flow from the probe tip to the sample and then estimate the thermal conductivities at different scanning positions. Experimental results and theoretical calculation demonstrate that SThM can be used as a tool for the thermal property and microstructural analysis of ...

2006-06-15

152

GIS for combined storage and analysis of data from terrestrial and synthetic aperture radar remote sensing deformation measurements in hard coal mining  

British Library Electronic Table of Contents (United Kingdom)

In this paper we demonstrate the capabilities of our ArcGIS-based software development that includes an adapted database system and a GIS tool for storage, combined analysis and visualization of leveling data and interferometric synthetic aperture radar (SAR) deformation measurements. Preprocessed remote sensing image data are stored with metadata that include all processing routines and parameters. This allows reproduction and traceability of all processing steps. Deformation monitoring is supported through data searching and selection based on a variety of criteria. A methods toolbox allows spatio-temporal analyses for points, lines and areas (e.g. subsidence basins) in a graphical manner.

2011-01-01

153

Earliest art in the Americas: incised image of a proboscidean on a mineralized extinct animal bone from Vero Beach, Florida  

British Library Electronic Table of Contents (United Kingdom)

A fragmented fossil bone incised with the figure of a proboscidean was recently found at Vero Beach, Florida near the location where Late Pleistocene fauna and human bones were recovered from 1913 to 1916. This engraving may represent the oldest and only existing example of Terminal Pleistocene art depicting a proboscidean in the Americas. Because of the uniqueness, rarity, and potential antiquity of this specimen, caution demanded that a variety of tests be used in an attempt to verify its authenticity. The mineralized bone was identified as mammoth, mastodon, or giant sloth. Rare earth element analysis was consistent with the fossil bone being ancient and originating at or near the Old Vero site (8-IR-9). Forensic analysis suggests the markings on the bone are not recent. Optical microsc...

2011-01-01

154

Cosmic ray antiproton/electron discrimination capability of the CAPRICE silicon-tungsten calorimeter using neural networks  

Energy Technology Data Exchange (ETDEWEB)

A data analysis based on an artificial neural network classifier is proposed to identify cosmic ray antiprotons detected with the CAPRICE silicon-tungsten imaging calorimeter against electron background in the energy range 1.2-4.0 GeV. A set of new physical variables, describing the events inside the calorimeter on the base of their different patterns, are introduced in order to discriminate between hadronic and electromagnetic showers. The ability of the artificial neural network classifier to perform a careful multidimensional analysis gives the possibility to identify antiprotons with an electron rejection 408{+-}85 (stat) at 95.0{+-}0.2 (stat)% of signal detection efficiency. The high accuracy achieved by this method improves substantially the efficiency in the evaluation of the cosmic ray antiproton spectrum. (orig.).

1996-11-01

155

Automated motion estimation of root responses to sucrose in two Arabidopsis thaliana genotypes using confocal microscopy  

British Library Electronic Table of Contents (United Kingdom)

Root growth is a highly dynamic process influenced by genetic background and environment. This paper reports the development of R scripts that enable root growth kinematic analysis that complements a new motion analysis tool: PlantVis. Root growth of Arabidopsis thaliana expressing a plasma membrane targeted GFP (C24 and Columbia 35S:LTI6b-EGFP) was imaged using time-lapse confocal laser scanning microscopy. Displacement of individual pixels in the time-lapse sequences was estimated automatically by PlantVis, producing dense motion vector fields. R scripts were developed to extract kinematic growth parameters and report displacement to ?0.1 pixel. In contrast to other currently available tools, Plantvis-R delivered root velocity profiles without interpolation or averaging across the root s...

2011-01-01

156

Application of nuclear analytical methods in determining heavy metals in a welder's working environment  

International Nuclear Information System (INIS)

The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).

1986-01-01

157

Structural Analysis for Gold Mineralization Using Remote Sensing and Geochemical Techniques in a GIS Environment: Island of Lesvos, Hellas  

International Nuclear Information System (INIS)

Exploration for epithermal Au has been active lately in the Aegean Sea of the eastern Mediterranean Basin, both in the islands of the Quaternary arc and in those of the back-arc region. The purpose of this study was the structural mapping and analysis for a preliminary investigation of possible epithermal gold mineralization, using remotely sensed data and techniques, structural and field data, and geochemical information, for a specific area on the Island of Lesvos. Therefore, Landsat-TM and SPOT-Pan satellite images and the Digital Elevation Model (DEM) of the study area were processed digitally using spatial filtering techniques for the enhancement and recognition of the geologically significant lineaments, as well as algebraic operations with band ratios and Principal Component Analysis (PCA), for the identification of alteration zones. Statistical rose diagrams and a SCHMIDT projection Stereo Net were generated from ...

2000-12-01

158

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom ...

159

View larger image for ISS022-E-26137 - Earth Sciences and Image ...  

Science.gov (United States)

The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...

160

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

161

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

162

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

163

3 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...

164

(Hadamard transform imaging)  

Science.gov (United States)

This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)

1990-01-01

165

Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill  

Energy Technology Data Exchange (ETDEWEB)

Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in ...

1997-06-01

166

Influence of sedation and data acquisition method on tracer uptake in animal models: ["1"2"3I]-2-iodo-L-phenylalanine in pentobarbital-sedated tumor-bearing athymic mice  

International Nuclear Information System (INIS)

Objectives: To minimize movement artifacts during tracer imaging studies, the animals are generally sedated. Although many reports describe the effect of barbiturates on brain function, less is published about the general impact on the extracerebral metabolism and tracer biodistribution. This report describes the influence of pentobarbital on tumor uptake of ["1"2"3I]-2-iodo-L-phenylalanine (["1"2"3I]-2I-L-PA) using dissection and nuclear imaging. Methods: R1M tumor-bearing athymic mice were divided into two populations: untreated and pentobarbital-treated. Each group was subjected to dynamic and static planar imaging and organ dissection after ["1"2"3I]-2I-L-PA injection. Two-compartment blood modeling was performed. Analysis of variance (ANOVA), t test and clustered boxplot analyses were used to compare the results between the treatment groups and between the data acquisition methods. Results: ...

2006-01-01

167

Focused ion beam damage to MOS integrated circuits  

Energy Technology Data Exchange (ETDEWEB)

Commercial focused ion beam (FIB) systems are commonly used to image integrated circuits (ICS) after device processing, especially in failure analysis applications. FIB systems are also often employed to repair faults in metal lines for otherwise functioning ICS, and are being evaluated for applications in film deposition and nanofabrication. A problem that is often seen in FIB imaging and repair is that ICS can be damaged during the exposure process. This can result in degraded response or out-right circuit failure. Because FIB processes typically require the surface of an IC to be exposed to an intense beam of 30--50 keV Ga{sup +} ions, both charging and secondary radiation damage are potential concerns. In previous studies, both types of effects have been suggested as possible causes of device degradation, depending on the type of device examined and/or the bias conditions. Understanding the causes of this damage is ...

2000-05-10

168

Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Accurate lung tumor tracking in real time is a keystone to image-guided radiotherapy of lung cancers. Existing lung tumor tracking approaches can be roughly grouped into three categories: (1) deriving tumor position from external surrogates; (2) tracking implanted fiducial markers fluoroscopically or electromagnetically; (3) fluoroscopically tracking lung tumor without implanted fiducial markers. The first approach suffers from insufficient accuracy, while the second may not be widely accepted due to the risk of pneumothorax. Previous studies in fluoroscopic markerless tracking are mainly based on template matching methods, which may fail when the tumor boundary is unclear in fluoroscopic images. In this paper we propose a novel markerless tumor tracking algorithm, which employs the correlation between the tumor position and surrogate anatomic features in the image. The positions of the surrogate features are not directly ...

2009-02-21

169

A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography  

International Nuclear Information System (INIS)

Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both ...

1999-11-01

170
172

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

173
180

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

181

Image Engine: an object-oriented multimedia database for storing, retrieving and sharing medical images and text.  

UK PubMed Central (United Kingdom)

This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available

1993-01-01

189

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

190

Failure analysis and defect review using extended accuracy of the CrossBeam {sup registered} Technology  

Energy Technology Data Exchange (ETDEWEB)

The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum system is ...

2005-07-01

191

Development of Intelligent Setting System for Fracture Based on X-Ray Image  

Energy Technology Data Exchange (ETDEWEB)

In order to achieve micro-wound, intelligence and high efficiency for fracture setting, intelligent setting system for fracture is proposed in accordance with biomechanics and fracture therapy theory. In the comprehensive medical system based on C-shape-arm X-machine, image processing and analysis is the core, programmable logical controller and stepping motor are important driving parts controlling mechanical parts. Six degree of freedom dynamics sensor ensures to control accurately force and moment. On the foundation of analyzing X-ray image peculiarities, method of processing and analysis is put forward, combining time domain with frequency domain. After mining domain knowledge in depth, setting actions is quantized into three non-continuous steps and is parameterized into two angles and one distance aiming at femoral-neck fracture. Objective features are extracted by virtue of three power ...

2006-10-15

192

Long-term Monitoring Plan for the Central Nevada Test Area  

Energy Technology Data Exchange (ETDEWEB)

The groundwater flow and transport model of the Faultless underground nuclear test conducted at the Central Nevada Test Area (CNTA) was accepted by the state regulator and the environmental remediation efforts at the site have progressed to the stages of model validation and long-term monitoring design. This report discusses the long-term monitoring strategy developed for CNTA. Subsurface monitoring is an expensive and time-consuming process, and the design approach should be based on a solid foundation. As such, a thorough literature review of monitoring network design is first presented. Monitoring well networks can be designed for a number of objectives including aquifer characterization, parameter estimation, compliance monitoring, detection monitoring, ambient monitoring, and research monitoring, to name a few. Design methodologies also range from simple hydrogeologic intuition-based tools to sophisticated statistical- and optimization-based tools. When designing the long-term ...

2003-09-02

193

Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR  

International Nuclear Information System (INIS)

Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience ...

2009-07-01

194

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-15

195

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-01

196

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...

2010-01-01

197

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

198

Esters useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

1981-08-18

199

Esters useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

200

Amides useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula

1981-07-21

201

Amides useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.

202

Video Analysis Transputer Array (VATA)  

Energy Technology Data Exchange (ETDEWEB)

This paper presents (a) an overview of the Inmos transputer and its use in parallel arrays for image processing, (b) a functional block-level description of IBM-AT-compatible boards for signal/image processing research using transputers with reconfigurable interconnection topologies, and (c) an overview of the OCCAM and C programming tools for placing parallel algorithms onto such a processor. The hardware consists of two custom printed-circuit boards (and two commercially available boards) within an IBM-AT host. The first provides a flexible input/output interface between a general-purpose high-speed input-data bus and the transputer array. The second contains 32 transputers and 4 programmable crossbar-switch interconnection chips. Several copies of the second board can be cascaded (or even partially-unpopulated) to provide for an arbitrary number of transputer chips. Each one of these boards will perform about 128 million Whetstones or, for ...

1988-08-19

203

Study of building materials impregnation processes by quasi-real-time neutron radiography  

International Nuclear Information System (INIS)

Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be presented. Quantitative ...

1999-11-03

204

STEM nanodiffraction technique for structural analysis of CoPt nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

Studying the structure of nanoparticles as a function of their size requires a correlation between the image and the diffraction pattern of single nanoparticles. Nanobeam diffraction technique is generally used but requires long and tedious TEM investigations, particularly when nanoparticles are randomly oriented on an amorphous substrate. We bring a new development to this structural study by controlling the nanoprobe of the Bright and Dark Field STEM (BF/DF STEM) modes of the TEM. The particularity of our experiment is to make the STEM nanoprobe parallel (probe size 1 nm and convergence angle <1 mrad) using a fine tuning of the focal lengths of the microscope illumination lenses. The accurate control of the beam position offered by this technique allowed us to obtain diffraction patterns of many single nanoparticles selected in the digital STEM image. By means of this technique, we demonstrate size effects on the order-disorder ...

2008-06-15

205

STEM nanodiffraction technique for structural analysis of CoPt nanoparticles  

International Nuclear Information System (INIS)

Studying the structure of nanoparticles as a function of their size requires a correlation between the image and the diffraction pattern of single nanoparticles. Nanobeam diffraction technique is generally used but requires long and tedious TEM investigations, particularly when nanoparticles are randomly oriented on an amorphous substrate. We bring a new development to this structural study by controlling the nanoprobe of the Bright and Dark Field STEM (BF/DF STEM) modes of the TEM. The particularity of our experiment is to make the STEM nanoprobe parallel (probe size 1 nm and convergence angle <1 mrad) using a fine tuning of the focal lengths of the microscope illumination lenses. The accurate control of the beam position offered by this technique allowed us to obtain diffraction patterns of many single nanoparticles selected in the digital STEM image. By means of this technique, we demonstrate size effects on the order-disorder transition ...

2008-06-01

206

Review of progress in quantitative NDE. Abstracts  

Energy Technology Data Exchange (ETDEWEB)

The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for ...

1986-01-01

207

Radiometric measurement of temperature distributions in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected ...

1989-03-01

208

PDE-based Non-Linear Diffusion Techniques for Denoising Scientific and Industrial Images: An Empirical Study  

Energy Technology Data Exchange (ETDEWEB)

Removing noise from data is often the first step in data analysis. Denoising techniques should not only reduce the noise, but do so without blurring or changing the location of the edges. Many approaches have been proposed to accomplish this; in this paper, they focus on one such approach, namely the use of non-linear diffusion operators. This approach has been studied extensively from a theoretical viewpoint ever since the 1987 work of Perona and Malik showed that non-linear filters outperformed the more traditional linear Canny edge detector. They complement this theoretical work by investigating the performance of several isotropic diffusion operators on test images from scientific domains. They explore the effects of various parameters such as the choice of diffusivity function, explicit and implicit methods for the discretization of the PDE, and approaches for the spatial discretization of the non-linear operator etc. They also compare ...

2001-12-20

209

Mid infrared observations of Van Maanen 2: no substellar companion.  

Energy Technology Data Exchange (ETDEWEB)

The results of a comprehensive infrared imaging search for the putative 0.06 M{sub {circle_dot}} astrometric companion to the 4.4 pc white dwarf van Mannen 2 are reported. Adaptive optics images acquired at 3.8 {micro}m reveal a diffraction limited core of 0.09 inch and no direct evidence of a secondary. Models predict that at 5 Gyr, a 50 M{sub J} brown dwarf would be only 1 magnitude fainter than van Maanen 2 at this wavelength and the astrometric analysis suggested a separation of 0.2 inch. In the case of a chance alignment along the line of sight, a 0.4 mag excess should be measured. An independent photometric observation at the same wavelength reveals no excess. In addition, there exist published ISO observations of van Maanen 2 at 6.8 {micro}m and 15.0 {micro}m which are consistent with photospheric flux of a 6750 K white dwarf. If recent brown dwarf models are correct, there is no substellar companion with T{sub eff} ...

2004-11-03

210

MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the ...

2002-07-01

211

MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography  

International Nuclear Information System (INIS)

The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the ...

2002-08-11

212

Infrared radiation features of coal and rocks under loading  

Energy Technology Data Exchange (ETDEWEB)

Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance detection. Generally, the infrared forewarning of coal rocks` failure comes later than that of acoustic and electrical resistance, but the infrared ...

1998-10-01

213

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI ...

2000-05-01

214

Focused ion beam machined nanostructures depth profiled by macrochannelling ion beam analysis  

International Nuclear Information System (INIS)

High aspect ratio sub-#mu#m periodic structures fabricated by focused ion beam (FIB) lithography have been characterised by Rutherford backscattering spectrometry (RBS) using the macrochannelling technique. The technique overcomes the limitations of complementary techniques such as scanning electron microscopy (SEM) and atomic force microscopy (AFM), which can provide images with sub-#mu#m resolution of just the surface features and not of the deep sub-surface structures, without destructive cross sectioning of the sample. Here RBS macrochannelling with a 2 MeV He"+ ion beam is used to analyse a diffraction grating fabricated by FIB milling an array of 100 nm wide trenches in a 300 nm thick Ag film on a Si substrate. Using the surface structure imaged by SEM and AFM as a starting point, a numerical model for the RBS spectrum from the grating is fitted to the experimental spectrum as a function of the sub-surface structure. This process allows ...

2006-08-01

215

Finned fuel element two-phase flow parameter measurements using real-time neutron radiography  

International Nuclear Information System (INIS)

The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration ...

2007-04-22

216

Finned fuel element two-phase flow parameter measurements using real-time neutron radiography  

International Nuclear Information System (INIS)

The measurement of two-phase flow parameters for development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with Freon 134a as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer present. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant ...

2008-02-01

217

A novel nanoglue and whole wafer self-alignment based upon self-assembled monolayers  

Science.gov (United States)

New methodologies for fabrication of multilevel packaging, particularly for RF signal analysis, are investigated. A new method for ``gluing'' silicon wafers together with a Self Assembled Monolayers (SAMs) based nanoglue are discussed, as are methods to enable its use with nonconforming wafers. Results of bond strength measurements as a function of temperature and process will be presented. Surface area bonded is characterized by infrared (IR) imaging. We will also present a method of inducing self-alignment between whole silicon wafers with micrometer precision. This represents a qualitative departure from alignment of millimeter-sized object as has been previously demonstrated. Self-alignment is induced by creating hydrophilic and hydrophobic regions on the wafers and using capillary forces of water in these regions to force the wafers to align with little to no outside influence. Results are characterized by IR imaging. ...

2008-10-01

218

The application of remote sensing methods for long-term and spatial analysis in open cast mining areas in Central Germany  

Energy Technology Data Exchange (ETDEWEB)

The intention of this study is to show the high potential of remote sensing data to keep an eye on longterm processes in large regions with widespread tasks and questions. The results of two projects (sponsored by the BMBF - Ministry of Education and Science, Germany and the country of Saxony-Anhalt) are taken into account to give an impression of the chances provided by the application of hyperspectral airborne scanner data and satellite images. So these two projects focus at the applicability of various methods to use remote sensing data for a long- term monitoring of former lignite open-cast mining areas. Apart from the traditional pixelorientated analysis, the application and combination of new object orientated methods (e.g. segmentation, texture analysis) were investigated to distinguish between the following typical vegetation types: Spontaneous revegetation of plant communities; reforestation areas; recultivated ...

2001-07-01

219

ALOS satellite imagery utilizations for safeguards  

International Nuclear Information System (INIS)

This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digital images. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an ...

2006-10-16

220

An Effective Method of Image Retrieval using Image Mining Techniques  

CERN Document Server

The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...

2010-01-01

221

The Application of Spatial Signature Analysis to Electrical Test Data: Validation Study  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the results of the Spatial Signature Analysis (SSA) Electrical-test (e-test) validation study that was conducted between February and June, 1998. SSA is an automated procedure developed by researchers at the Oak Ridge National Laboratory to address the issue of intelligent data reduction while providing feedback on current manufacturing processes. SSA was initially developed to automate the analysis of optical defect data. Optical defects can form groups, or clusters, which may have a distinct shape. These patterns can reveal information about the manufacturing process. Optical defect SSA uses image processing algorithms and a classifier system to interpret and identify these patterns, or signatures. SSA has been extended to analyze and interpret electrical test data. The algorithms used for optical defect SSA have been adapted and applied to e-test binmaps. An image of the binmap is ...

1999-03-15

222

Rapid yield learning through optical defect and electrical test analysis  

Energy Technology Data Exchange (ETDEWEB)

As semiconductor device density and wafer area continue to increase, the volume of in-line and off-line data required to diagnose yield-limiting conditions is growing exponentially. To manage this data in the future, analysis tools will be required that can automatically reduce this data to useful information, e.g., by assisting the engineer in rapid root-cause diagnosis of defect generating mechanisms. In this paper, the authors describe a technology known as Spatial Signature Analysis (SSA) and its application to both optically-detected defect data as well as electrical test (e-test) bin data. The results of a validation study are summarized that demonstrate the effectiveness of the SSA approach on optical defect wafermaps through field-testing at three semiconductor manufacturing sites on ASIC, DRAM and SRAM products. This method has been extended to analyze and interpret electrical test data and to provide a pathway for correlation of this ...

1998-02-01

223

Comparison of normal adult and children brain SPECT imaging using statistical parametric mapping(SPM)  

Energy Technology Data Exchange (ETDEWEB)

This study compared rCBF pattern in normal adult and normal children using statistical parametric mapping (SPM). The purpose of this study was to determine distribution pattern not seen visual analysis in both groups. Tc-99m ECD brain SPECT was performed in 12 normal adults (M:F=11:1, average age 35 year old) and 6 normal control children (M:F=4:2, 10.5{+-}3.1y) who visited psychiatry clinic to evaluate ADHD. Their brain SPECT revealed normal rCBF pattern in visual analysis and they were diagnosed clinically normal. Using SPM method, we compared normal adult group's SPECT images with those of 6 normal children subjects and measured the extent of the area with significant hypoperfusion and hyperperfusion (p<0.001, extent threshold=16). The areas of both angnlar gyrus, both postcentral gyrus, both superior frontal gyrus, and both superior parietal lobe showed significant hyperperfusion in normal adult group ...

2002-07-01

224

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...

2007-04-15

225

Young Cypriots' perspectives of the symbolic values of smoking  

British Library Electronic Table of Contents (United Kingdom)

This paper reports the findings of a study that explores the perspectives of 25 young Cypriots regarding the symbolic values of smoking with respect to their everyday lived experiences. This study was motivated by recognising the high levels of smoking prevalence among adolescents in Cyprus and the absence of published research 'recording' their own versions of reality about smoking. Data for the study were generated from one-to-one qualitative interviews which encouraged the participants to articulate the symbolic value of smoking in their day-to-day experiences. The analysis focuses first, on the content of the embedded symbolic values of smoking (e.g. the quality of being 'cool') and second on the role of these values (e.g. used in projecting an image) in their everyday lives. A central...

2010-01-01

226

Wave extrapolation in the spatial wavelet domain with application to poststack reverse-time migration  

Energy Technology Data Exchange (ETDEWEB)

A wavelet transformation is performed over each of the spatial coordinates of the scalar wave equation. This transformed equation is solved directly with a finite-difference scheme for both homogeneous and smooth inhomogeneous media. Wavefield extrapolation is performed completely in the spatial wavelet domain without transforming back into the space domain at each time step. The wavelet coefficients are extrapolated, rather than the wavefield itself. The numerical solution of the scalar wave equation in the spatial wavelet domain is closely related to the finite-difference method because of the compact support of the wavelet bases. Poststack reverse-time migration is implemented as an application. The resolution spaces of the wavelet transform provide a natural framework for multigrid analysis. Migrated images are constructed from various resolution spaces.

1998-03-01

227

Three-dimensional, three-component wall-PIV  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set simulating a rotating sphere. (orig.)

2010-06-15

228

Serial Intravascular Ultrasound Analysis of the Impact of Myocardial Bridge on Neointimal Proliferation After Coronary Stenting in Patients with Acute Myocardial Infarction  

British Library Electronic Table of Contents (United Kingdom)

Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...

2010-01-01

229

Phase formation sequence in the Pd-GaAs system  

Energy Technology Data Exchange (ETDEWEB)

The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.

1985-12-01

230

Monitoring urban land cover and vegetation change by multi-temporal remote sensing information  

British Library Electronic Table of Contents (United Kingdom)

In order to analyze changes in human settlement in Xuzhou city during the past 20 years, changes in land cover and vegetation were investigated based on multi-temporal remote sensing Landsat TM images. We developed a hierarchical classifier system that uses different feature inputs for specific classes and conducted a classification post-processing approach to improve its accuracy. From our statistical analysis of changes in urban land cover from 1987 to 2007, we conclude that built-up land areas have obviously increased, while farmland has seen in a continuous loss due to urban growth and human activities. A NDVI difference approach was used to extract information on changes in vegetation. A false change information elimination approach was developed based on prior knowledge and statistic...

2010-01-01

231

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

232

Landscape pattern MACRS analysis and the optimal utilization of Shiyang River Basin based on RS and GIS approach  

British Library Electronic Table of Contents (United Kingdom)

Chose the arid interior district Shiyang River basin four issues of Landsat/TM images from 1986 to 2006 to visually interpret, and analyze the natural succession of ecological environment and the landscape pattern characteristic under the human activity interference. The results showed that in past 20years, the number of landscape patch has increased, but the average patch size was decreasing, which explained that the landscape fragmentation degree was increasing, the landscape integrity was declining. The edge density of landscape remained invariable basically, which explained its stability maintained good. The diversity and evenness index continually enhanced, the diversity increased from 0.73 in 1986 to 0.84 in 2006. The mean core patch area of study area reduced from134.47hm2 in 1994 t...

2009-01-01

233

Estimation of plasma density by surface plasmons for surface-wave plasmas  

International Nuclear Information System (INIS)

An estimation method of plasma density based on surface plasmons theory for surface-wave plasmas is proposed. The number of standing-wave is obtained directly from the discharge image, and the propagation constant is calculated with the trim size of the apparatus in this methods, then plasma density can be determined with the value of 9.1 x 1017 m-3. Plasma density is measured using a Langmuir probe, the value is 8.1 x 1017 m-3 which is very close to the predicted value of surface plasmons theory. Numerical simulation is used to check the number of standing-wave by the finite-difference time-domain (FDTD) method also. All results are compatible both of theoretical analysis and experimental measurement. (authors)

2008-12-01

234

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

235

EXPLAINING THE UNEXPECTED SUCCESS OF THE SMOKING BAN IN ITALY: POLITICAL STRATEGY AND TRANSITION TO PRACTICE, 2000-2005  

British Library Electronic Table of Contents (United Kingdom)

The approval (2003) and enforcement (2005) of a smoking ban in Italy have been viewed by many as an unexpectedly successful example of policy change. The present paper, by applying a processualist approach, concentrates on two policy cycles between 2000 and 2005. These had opposing outcomes: an incomplete decisional stage and an authoritative decision, enforced two years later. Through the analysis of the different phases of agenda setting, alternative specification and decision making, we have compared the quality of participation of policy entrepreneurs in the two cycles, their political strategies and, in these, the relevance of issue image. The case allows us to direct the attention of scholars and practitioners to an early phase of the policy implementation process - which we have nam...

2010-01-01

236

Crack tip opening angle measurement through a girth weld in an X100 steel pipeline section  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT Crack tip opening angle (CTOA) is becoming one of the most accepted methods for characterizing fully plastic fracture. It provides a measure of the resistance to fracture for a material in cases where there is a large degree of stable-tearing crack extension during the fracture process. Our current pipeline research uses the CTOA test as an alternative, or addition, to the CTOD (crack tip opening displacement) and the fracture energy characterization provided by the J-integral approach. A test technique was developed for measurement of CTOA that uses a modified double cantilever beam (MDCB) specimen. A digital camera and image analysis software were used to record the progression of the crack tip and to estimate the CTOA. In this article, CTOA data on crack growth orientations per...

2008-01-01

237

Cosmic magnification: nulling the intrinsic clustering signal  

CERN Document Server

We investigate the extent to which the pure magnification effect of gravitational lensing can be extracted from galaxy clustering statistics, by a nulling method which aims to eliminate terms arising from the intrinsic clustering of galaxies. The aim is to leave statistics which are free from the uncertainties of galaxy bias. We find that nulling can be done effectively, leaving data which are relatively insensitive to uncertainties in galaxy bias and its evolution, leading to cosmological parameter estimation which is effectively unbiased. This advantage comes at the expense of increased statistical errors, which are in some cases large, but it offers a robust alternative analysis method to cosmic shear for cosmological imaging surveys designed for weak lensing studies, or to full modelling of the clustering signal including magnification effects.

2011-01-01

238

Conventional and back-side focused ion beam milling for off-axis electron holography of electrostatic potentials in transistors  

International Nuclear Information System (INIS)

Off-axis electron holography is used to characterize a linear array of transistors, which was prepared for examination in cross-sectional geometry in the transmission electron microscope (TEM) using focused ion beam (FIB) milling from the substrate side of the semiconductor device. The measured electrostatic potential is compared with results obtained from TEM specimens prepared using the more conventional 'trench' FIB geometry. The use of carbon coating to remove specimen charging effects, which result in electrostatic fringing fields outside 'trench' specimens, is demonstrated. Such fringing fields are not observed after milling from the substrate side of the device. Analysis of the measured holographic phase images suggests that the electrically inactive layer on the surface of each FIB-milled specimen typically has a thickness of 100 nm.

2005-04-01

239

Application of digital radiography to diagnosis of laryngeal diseases  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with ...

1986-01-01

240

Adrenal incidentaloma: Does an adequate workup rule out surprises?  

British Library Electronic Table of Contents (United Kingdom)

Background Adrenal incidentaloma remains a diagnostic challenge. Despite well-established management guidelines, the long-term results of following these guidelines are unknown. We sought to determine how accurately these guidelines identify functioning incidentalomas and how often these guidelines result in adrenalectomy for benign tumors. Methods We catalogued adrenal incidentalomas from a retrospective review of 500 consecutive adrenalectomies at a single institution. The outcome measures studied were patient demographics, preoperative biochemical analysis, imaging characteristics, tumor size, type of operation performed, and postoperative histologic diagnosis. Results Eighty-one of the 500 adrenalectomies performed were for incidentalomas. Size was the only significant characteristic t...

2010-01-01

241

Petrophysical Analysis and Geographic Information System for San Juan Basin Tight Gas Reservoirs  

Energy Technology Data Exchange (ETDEWEB)

The primary goal of this project is to increase the availability and ease of access to critical data on the Mesaverde and Dakota tight gas reservoirs of the San Juan Basin. Secondary goals include tuning well log interpretations through integration of core, water chemistry and production analysis data to help identify bypassed pay zones; increased knowledge of permeability ratios and how they affect well drainage and thus infill drilling plans; improved time-depth correlations through regional mapping of sonic logs; and improved understanding of the variability of formation waters within the basin through spatial analysis of water chemistry data. The project will collect, integrate, and analyze a variety of petrophysical and well data concerning the Mesaverde and Dakota reservoirs of the San Juan Basin, with particular emphasis on data available in the areas defined as tight gas areas for purpose of FERC. A relational, geo-referenced database ...

2008-10-01

242

Performance study of teleradiology network systems with CRT monitors. ROC analysis of an observation study of simulated lung nodules  

International Nuclear Information System (INIS)

To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to indicate the presence ...

243

Investigation of sulfonated aromatic compound (SAC) modification to nylon film. 2. Study of SAC sorption isotherm and atomic force microscopic characterization of nylon surfaces  

Energy Technology Data Exchange (ETDEWEB)

Nylon 6 and nylon 66 films have been treated with aqueous sulfonated aromatic compound (SAC) solutions at concentrations ranging from 0.005 to 1.0 wt%. SAC uptakes at different treatment concentrations were measured and found to follow a BET isotherm. The surface morphologies of nylon film samples, including the original and SAC-treated films, have been characterized by atomic force microscopy (AFM). For untreated nylon 6 and nylon 66 films, AFM images show a randomly distributed fibrillar surface structure. Characteristic widths of fibrils in the nylon 66 and 6 films were 150-225 and 75-150 nm, respectively. For SAC-treated nylon films, the AFM images revealed that the surfaces of the films became covered with nodule-like features having a diameter range of 25-60 nm. AFM analysis provides evidence that SAC treatment deposited a surface coating on nylon films. AFM images of SAC-treated nylon films ...

1995-08-01

244

Determination of anisotropic velocity model by reflection tomography of compression and shear modes; Determination de modele de vitesse anisotrope par tomographie de reflexion des modes de compression et de cisaillement  

Energy Technology Data Exchange (ETDEWEB)

As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, we extend the isotropic bending ray ...

2001-12-01

245

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-07-01

246

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

247

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

248

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

249

Oxide growth on aluminium alloys in the presence of ammonium fluoborate  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study as to determine the mechanisms involved in using ammonium fluoborate as a reducing atmosphere when preheating a high magnesium content aluminium alloy. Rutherford Backscattering (RBS) has been the major technique used in the analysis of samples, it revealed significant reduction in both the diffusion of magnesium to the surface and the calculated oxide thickness in the presence of NH{sub 4}BF{sub 4}. At temperatures above 500 deg C in air, SEM images revealed depressions and voids due to incipient melting at various stages, around the grain boundaries. Grain boundaries effectively acted as pipes aiding the diffusion of magnesium to the surface. These results have been verified through compositional analysis with both RBS and auger electron spectroscopy (AES). Results from NH{sub 4}BF{sub 4} atmosphere preheat conditions showed significant improvements. It was verified experimentally that above 500 deg ...

1996-12-31

250

Controllable synthesis of graphene sheets with different numbers of layers and effect of the number of graphene layers on the specific capacity of anode material in lithium-ion batteries  

International Nuclear Information System (INIS)

High quality graphene sheets are synthesized through efficient oxidation process followed by rapid thermal expansion and reduction by H2. The number of graphene layers is controlled by tuning the oxidation degree of GOs. The higher the oxidation degree of GOs is getting, the fewer the numbers of graphene layers can be obtained. The material is characterized by elemental analysis, thermo-gravimetric analysis, scanning electron microscopy, atomic force microscopy, transmission electron microscopy and Fourier transform infrared spectroscopies. The obtained graphene sheets with single, triple and quintuplicate layers as anode materials exhibit a high reversible capacity of 1175, 1007, and 842 mA h g-1, respectively, which show that the graphene sheets with fewer layers have higher reversible capacity. -- Graphical abstract: The typical TEM images of the graphene sheets derived from GO3(a), GO2(b) and GO1(c). Display Omitted ...

2011-05-01

251

A variability study of the first catalog of gamma-ray sources on the 2.3 years AGILE data archive  

Science.gov (United States)

AGILE pointed observations performed from July 9, 2007 to October 30, 2009 are a recent, high quality gamma-ray data archive for monitoring studies of medium to high brightness gamma-ray sources in the 30 MeV -50 GeV energy range. We present a variability study of the 1AGL sources over the complete AGILE pointed Observation Blocks (OBs) dataset. The first AGILE Gamma-Ray Imaging Detector (GRID) catalog (Pittori et al. 2009) included a significance-limited (4 sigma) sample of 47 sources (1AGL), detected with a conservative analysis over a first-year non-uniform sky coverage dataset. In this analysis we used data of an improved full Field of View (FOV) event filter, on a much larger (about 27.5 months) observation dataset, analyzing each OB separatedly. This data processing resulted in an improved source list as compared to the 1AGL one. We present here some results on the variability of some of these sources.

2010-01-01

252

Detection of pollution-induced forest decline in the Kola Peninsula using remote sensing and mathematical modelling  

Energy Technology Data Exchange (ETDEWEB)

Forests on the Kola Peninsula in Northern Russia grow close to the northern tree line. They are subjected to both natural and anthropogenic stress factors. The Cu-Ni smelter 'Severonikel' (Lat. 67 deg 55'N; Long. 32 deg 57'E) near Monchegorsk is one of the two major sources of sulphur dioxide and heavy metals emissions on the Kola Peninsula. These emissions have caused significant deterioration of the surrounding vegetation. The thesis demonstrates how methods of Remote sensing, ground survey and mathematical modelling can be integrated for monitoring of the smelter's environmental impact on the surrounding vegetation: ground truth data are used for calibration of remote-sensed data, which further serve to verify mathematical models. The study aims were: * to estimate the scale of airborne sulphur pollution from the smelting industry on the Kola Peninsula and its effect on vegetation; * to assess spatial extent of the forest decline in the ...

1998-07-01

253

Boundary Migration in Rutile  

Energy Technology Data Exchange (ETDEWEB)

TiO{sub 2} is a vital material in several technologies including, photocatalysis, gas sensing, biomaterials and optical coatings. Among the several crystal structures of this oxide, rutile has the highest density and microhardness, the highest index of refraction and the highest temperature stability. The processing of dense polycrystalline materials often includes the addition of a liquid-forming phase at higher temperatures. This technique is known as liquid-phase sintering and has been studied extensively. Rutile boundaries containing an amorphous phase have been used to study boundary migration and grain-boundary grooving. Visible-light (VLM), scanning electron (SEM) and transmission electron microscopy (TEM) in addition to electron-backscatter diffraction (EBSD) and a focused-ion beam (FIB) tool were used to characterize boundary migration in rutile. EBSD analysis was carried out on a Philips XL30 FEG SEM equipped with a DigiView 1612 high-resolution, ...

2003-08-01

254

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...

1992-01-01

255

High-resolution brain SPECT imaging in attention deficit hyperactivity disorder children without comorbidity: quantitative analysis using statistical parametric mapping(SPM)  

Energy Technology Data Exchange (ETDEWEB)

We examined the abnormalities of regional cerebral blood flow(rCBF) in children with attention deficit hyperactivity disorder(ADHD) without comorbidity using statistical parametric mapping(SPM) method. We used the patients with not compatible to DSM-IV diagnostic criteria of ADHD and normal rCBF pattern in visual analysis as normal control children. Tc-99m ECD brain SPECT was performed on 75 patients (M:F=64:11, 10.0{+-}2.5y) with the DSM-IV diagnostic criteria of ADHD and 13 normal control children (M:F=9:4, 10.3{+-}4.1y). Using SPM method, we compared patient group's SPECT images with those of 13 control subjects and measured the extent of the area with significant hypoperfusion(p<0.01) in predefined 34 cerebral regions. Only on area of left temporal lobe showed significant hypoperfusion in ADHD patients without comorbidity (n=75) compared with control subjects(n=13). (n=75, p<0.01, extent threshold=16). rCBF of left ...

2002-07-01

256

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

257

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

258

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

259

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

260

Nonnegative Factorization of Diffusion Tensor Images and Its Applications  

UK PubMed Central (United Kingdom)

This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available

2011-01-01

261

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

262

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

263

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

264

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

265

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

266

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

267

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

268

Comprehensive Quantification of Signal-to-Noise Ratio and g-Factor for Image-Based and k-Space-Based Parallel Imaging Reconstructions  

UK PubMed Central (United Kingdom)

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available

2008-10-01

269

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...

2007-09-21

270

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

271

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-01-01

272

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

273

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

274

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

275

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

276

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

277

Typhoon Aere : Image of the Day - NASA Earth Observatory  

Science.gov (United States)

Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...

278

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

279

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

280

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

281

Method for the reduction of image content redundancy in large image databases  

Energy Technology Data Exchange (ETDEWEB)

A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.

2010-03-02

282

JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469  

Science.gov (United States)

Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner

1993-01-01

283

Imaging subsurface using cross-correlation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.

1997-12-31

284

An analysis strategy for safeguards use of optical satellite imagery  

International Nuclear Information System (INIS)

This paper outlines conceptual framework for safeguards remote sensing, and suggests a strategy for overcoming the challenges to full exploitation of all types of optical satellite imagery. Since the introduction of commercial open-source high-resolution satellite imagery in 1999, it has become an important tool for verification of declarations, baseline mapping, detection and monitoring of changes and investigation of undeclared activities. Its use is still relatively restricted, but there is a growing demand for wider satellite reconnaissance support, and the Satellite Image Analysis Unit (SIAU) has recently been expanded in response. For a number of reasons, IAEA safeguards use of satellite imagery is largely based on visual interpretation by experienced image analysts of high-resolution monochromatic imagery to monitor and characterize buildings and structures on safeguards sites. The very wide range of remote sensing ...

2006-10-16

285

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

286

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...

2001-01-01

287

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...

2001-10-01

288

RADIAL DISTRIBUTION OF STARS, GAS AND DUST IN SINGS GALAXIES. I. SURFACE PHOTOMETRY AND MORPHOLOGY  

International Nuclear Information System (INIS)

We present ultraviolet through far-infrared (FIR) surface brightness profiles for the 75 galaxies in the Spitzer Infrared Nearby Galaxies Survey (SINGS). The imagery used to measure the profiles includes Galaxy Evolution Explorer UV data, optical images from Kitt Peak National Observatory, Cerro Tololo Inter-American Observatory, and Sloan Digital Sky Survey, near-IR data from Two Micron All Sky Survey, and mid- and FIR images from Spitzer. Along with the radial profiles, we also provide multi-wavelength asymptotic magnitudes and several nonparametric indicators of galaxy morphology: the concentration index (C 42), the asymmetry (A), the Gini coefficient (G), and the normalized second-order moment of the brightest 20% of the galaxy's flux (M-bar20). In this paper, the first of a series, we describe the technical aspects regarding the surface photometry, and present a basic analysis of the global and structural properties of ...

2009-10-01

289

Visible Earth: Typhoon Aere  

Science.gov (United States)

NASA's Visible Earth catalog of NASA images and animations of our home planet.

292

Theoretical study of subwavelength imaging by acoustic metamaterial slabs  

CERN Document Server

We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.

2009-01-01

300

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

302

Lead-203 for skeletal imaging  

International Nuclear Information System (INIS)

... biological variability body distribution kidneys labelled compounds lead 203

304

Introduction to Three Dimensional Reconstruction of Brain C. T. Image  

International Nuclear Information System (INIS)

The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.

1986-11-01

312

Fundamental study on Fuji Computed Radiography (FCR) image  

International Nuclear Information System (INIS)

Japanese (Mar 1986). Japan Tomiyoshi, Tsukasa Kakoi, Iwao Fukushima,

1986-01-01

315

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

326

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

328

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

329

Utilization of fractional Brownian motion in constrained least-squares restoration of medical images  

International Nuclear Information System (INIS)

Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.

330

Document image retrieval with morphology-based segmentation and features combination  

Science.gov (United States)

Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...

2011-01-01

331

Comparative evaluation of /sup 99m/Tc GH, /sup 99m/TcO_4, and /sup 99m/Tc DTPA as brain imaging agents  

International Nuclear Information System (INIS)

The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.

332

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

333

Cutaneous gallium uptake in patients with AIDS with mycobacterium avium-intracellulare septicemia  

International Nuclear Information System (INIS)

Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.

334

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ...

2003-11-01

335

Synthesis and characterization of ["1"2"5I]-N-(N-benzylpiperidin-4-YL)-4-iodobenz amide, a potential high affinity sigma ligand for imaging breast cancer  

International Nuclear Information System (INIS)

Three regio-isomers of N-(N-benzylpiperidin-4-yl)-4-iodobenzamide, IBP, were prepared and evaluated for their sigma affinities. All three isomers (2, 3, and 4-substituted) showed high affinities for sigma-1 receptors in guinea pig brain membranes (Ki - 1.64 nM, 3.02 nM, 1.70 nM respectively) against ["3H]-(+)-pentazocine, a sigma-1 selective ligand. 2-IBP and 4-IBP showed modest affinities for sigma-2 sites in rat liver (Ki = 29.6 nM. 25.2 nM respectively) against ["3H]DTG in the presence of dextrallorphan to mask sigma-1 sites. The homologous competition binding studies of 4-["1"2"5I]BP in MCF-7 human breast tumor cells showed high affinity dose-dependent binding. Competition binding studies with haloperidol and DTG also showed a high affinity binding (Ki = 4.6 nM, 60 nM respectively), demonstrating the sigma specificity. The saturation binding (Scatchard analysis) of ["3H]DTG with MCF-7 cell membrane preparations gave Kd of 24.54 nM and a Bmax of 2071 fmol/mg ...

1994-08-21

336

Size and morphology of fine particle emissions from heavy-duty vehicles; Raskaan ajoneuvokannan hiukkaspaeaestoen koko ja morfologia - HD-PM  

Energy Technology Data Exchange (ETDEWEB)

Exhaust fine and ultra fine particle numbers, particle sizes, mass, shape, structure and density were studied from Euro II - EEV emission level heavy-duty vehicles. For total particle emission factors city buses were run on dynamic conditions simulating city bus driving. The new heavy-duty chassis dynamometer of VTT was used. Vehicles were a comprehensive sample of current city bus fleet, the type approved emission level of which was Euro II - Euro III. Also cleaner engines of Euro IV to EEV targeted emission level were included: CRT, CNG, DPF. Particle emissions of these buses were extremely low; numbers 1/100 - 1/1000 and masses 1/10 - 1/100 of those of the predominating techniques. Morphological properties of fine particle populations that represent majority of particle size distribution (Da < 500 nm) are being analyzed by image processing (Matlab) from electron microscopical images (SEM, ESEM and TEM) as a function of particle size. ...

2004-07-01

337

Results of the remote sensing feasibility study for the uranium hexafluoride storage cylinder yard program  

Energy Technology Data Exchange (ETDEWEB)

The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to $1,500K per annum just ...

1997-02-01

338

Menstrual variation of breast volume and T{sub 2} relaxation times in cyclical mastalgia  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Hormonal activity causes breast volume to change during the menstrual cycle. One possible cause of this volume change is thought to be due to water retention or oedema within the tissues. We used magnetic resonance imaging (MRI) to study the variation in breast volume and {sup 1}H Magnetic Resonance Spectroscopy (MRS) to measure T{sub 2} relaxation times which are known to increase with increasing tissue water content. We hypothesised that an increase in breast volume will elevate T{sub 2} relaxation due to the presence of an increased water content within the breast. T{sub 2} Relaxation time and volume were studied in fifteen control subjects and in a cohort of eight patients with cyclical mastalgia in order to determine whether changes in breast volume and T{sub 2} relaxation times differed in controls and patients during menses, ovulation and premenses. Method: Breast volume was determined by the Cavalieri method in combination with point counting ...

2008-02-15

339

Facet joint injuries in acute cervical spine trauma : evaluation with CT and MRI  

Energy Technology Data Exchange (ETDEWEB)

To evaluate injury patterns of facet joints and associated soft tissue injuries in patients with acute traumatic cervical facet joint injuries. From among patients with cervical spine trauma, 27 with facet joint injuries, as seen on CT and MRI, were chosen for this study. CT scans were analyzed with regard to the location of facet joint injury, the presence or absence of facet dislocation or fracture, and other associated fractures. MR images were analyzed with regard to ligament injury, intervertebral disc injury, intervertebral disc herniation, and spinal cord injury. The most common location of facet joint injury was C6-7 level(n=10), followed by C5-6(n=8). Among these 27 patients with facet joint injuries, 12(44%) had bilateral injuries and 15(56%) unilateral injuries. Facet fractures were present in 17 cases(63%) and the fracture of inferior facet was more frequent than superior. Patterns of fracture were vertical, transverse, or comminuted, but vertical ...

1999-05-01

340

Experimental studies of the turbulence structures of impinging reacting jets using time-resolved particle image velocimetry visualisation, hot wire anemometry and acoustic signal processing  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the turbulence structures of premixed impinging jets are investigated by three different experimental techniques: time-resolved particle image velocimetry (TPIV) visualisation, hot wire anemometry (HWA) and acoustic signal processing. The focus is on the TPIV, with the other two techniques providing supplementary information. The 2-D velocities of the impinging jets were obtained by TPIV. The contour maps of velocity derivatives were computed to facilitate the visualisation of the turbulence structure of the reactant part of turbulent impinging flames. Particular attention was concentrated on the turbulence structures out of the burner nozzle and their interactions with the combustion process. It was found that the contour plots are effective in visualising time-dependent structures. It is demonstrated that the derivatives of the velocity field are able to reveal many otherwise hidden turbulence patterns. Test cases were designed to facilitate easy ...

2000-12-01

341

Disorders of brain development and phakomatosis  

International Nuclear Information System (INIS)

Full text: Disorders of brain development and phakomatosis are resulting from disturbed embryonic-foetal development One third of all major embryological anomalies involve CNS, and over 2000 different anomalies have been described. Anomalies of the brain often cause foetal and neonatal death, and mental and physical retardation in pediatric group. The majority of disorders of brain development and phakomatosis are idiopathic, and most of them are not hereditary or familial. Ultrasonography plays the important role in screening foetal and neonatal brain, but after closure of fontanels it is difficult to find the acoustic window. CT has limited contrast resolution, and disadvantage exposing infant to ionizing radiation. It is helpful to demonstrate the presence of calcifications. MR imaging has proved to be a diagnostic tool of major importance in children with disorders of brain development and phakomatosis. The excellent grey/white matter differentiation and ...

342

Development of homogeneous mixing technology of dispersion nuclear fuel  

Energy Technology Data Exchange (ETDEWEB)

The measurement methods of homogeneity of dispersion fuel were analyzed. The effects of mixing method, rotating speed, particle shape, particle size and moisture content on homogeneity of U{sub 3}Si/Al powder mixture were characterized by the apparent density measurement. The effects of fuel particle shape on green properties and optimum compaction conditions were investigated in U{sub 3}Si{sub 2}/Al powder compacts. 3 kinds of measurement method on the homogeneity were analyzed by apparent density measurement method, x-ray image contrast method and image analysis method of mixed powders or fuel rods. The homogeneity of dispersed fuel powder mixture was analyzed using three kinds of mixing, by apparent density measurements method. The homogeneity of powder mixture increased with rotating speed of the V-shape tumbler mixer. The comminuted irregular shaped particles and smaller particle size of fuel powders showed homogeneity ...

2000-04-01

343

Characterization of flame front surfaces in turbulent premixed methane/air combustion  

Energy Technology Data Exchange (ETDEWEB)

A detailed experimental investigation of the application of fractal geometry concepts in determining the turbulent burning velocity in the wrinkled flame regime of turbulent premixed combustion was conducted. The fractal dimension and cutoff scales were determined for six different turbulent flames in the wrinkled flame regime, where the turbulence intensity, turbulent length scale, and equivalence ratio were varied. Unlike previous reports, it has proved possible to obtain the fractal dimension and inner and outer cutoffs from individual flame images. From this individual data, the pdf distributions of all three fractal parameters, along with the distribution of the predicted increase in surface area, may be determined. The analysis of over 300 flame images for each flame condition provided a sufficient sample size to accurately define the pdf distributions and their means. However, the predicted S{sub T}/S{sub L}, ...

1995-06-01

344

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The process is observed to be dominated by the ...

1988-11-01

345

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. ...

346

Eddy current signal analysis techniques for assessing degradation of support plate structures in nuclear steam generators  

Energy Technology Data Exchange (ETDEWEB)

The steam generator (SG) is one of the most critical components of the heat transfer system in nuclear generation stations. Testing the structural integrity of SG tubing and SG internals is a key element of the fitness-for-service assessments to assure the safe and continuous operation of nuclear power plants. Recent eddy current (ET) inspections of two nuclear power plants revealed degradation of some of the tube support plate (TSP) structures, which was also confirmed by visual inspection. The phenomena was described as metal loss, caused by flow-accelerated corrosion of the carbon steel trefoil support plate and varying from minor to complete loss of the ligaments. This loss of TSP ligaments results in lack of support for the adjacent tubes making them more susceptible to fretting-wear damage and fatigue cracking. A signal analysis method, based on the responses at low frequency of two types of eddy current probes, has been developed to assess the degree of ...

2006-07-01

347

Visualization by PIV of dynamic stall on a vertical axis wind turbine  

Energy Technology Data Exchange (ETDEWEB)

The aerodynamic behavior of a vertical axis wind turbine (VAWT) is analyzed by means of 2D particle image velocimetry (PIV), focusing on the development of dynamic stall at different tip speed ratios. The VAWT has an unsteady aerodynamic behavior due to the variation with the azimuth angle {theta} of the blade's sections' angle of attack, perceived velocity and Reynolds number. The phenomenon of dynamic stall is then an inherent effect of the operation of a VAWT at low tip speed ratios, impacting both loads and power. The present work is driven by the need to understand this phenomenon, by visualizing and quantifying it, and to create a database for model validation. The experimental method uses PIV to visualize the development of the flow over the suction side of the airfoil for two different reference Reynolds numbers and three tip speed ratios in the operational regime of a small urban wind turbine. The field-of-view of the experiment covers ...

2009-01-15

348

The uterine blush. A potential false-positive in Meckel's scan interpretation  

Energy Technology Data Exchange (ETDEWEB)

To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative ...

1982-10-01

349

Surface physics with cold and thermal neutron reflectometry. Progress report, April 1, 1991--March 31, 1992  

Energy Technology Data Exchange (ETDEWEB)

Three aspects of the research project ``Surface physics with cold and ultracold neutron reflectometry`` were stressed during the present first year: (1) Setup of the reflectometer facility at the research reactor of the Rhode Island Nuclear Science Center. The installation provides a narrow ``pencil beam`` analyzed by time of flight using a chopper system. Following beam characterization and a test measurement of the total cross section of copper single crystal first reflectivity measurements are currently performed using a supermirror. (2) Design stud for the ultracold neutron imaging system, with involvement of the relevant industry. Bids are available for several components indicating that it will be very difficult to build the entire system unless further funds become available. (3) Analysis of features of neutron reflection from surfaces with special emphasis on the effect of surface roughness both on the specular beam and the diffusely ...

1991-11-01

350

Surface physics with cold and thermal neutron reflectometry  

Energy Technology Data Exchange (ETDEWEB)

Three aspects of the research project Surface physics with cold and ultracold neutron reflectometry'' were stressed during the present first year: (1) Setup of the reflectometer facility at the research reactor of the Rhode Island Nuclear Science Center. The installation provides a narrow pencil beam'' analyzed by time of flight using a chopper system. Following beam characterization and a test measurement of the total cross section of copper single crystal first reflectivity measurements are currently performed using a supermirror. (2) Design stud for the ultracold neutron imaging system, with involvement of the relevant industry. Bids are available for several components indicating that it will be very difficult to build the entire system unless further funds become available. (3) Analysis of features of neutron reflection from surfaces with special emphasis on the effect of surface roughness both on the ...

1991-11-01

351

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

Energy Technology Data Exchange (ETDEWEB)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned ...

2005-04-01

352

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

International Nuclear Information System (INIS)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned ...

2005-04-01

353

Subcellular distribution of ryanodine receptors in the cardiac muscle of carp (Cyprinus carpio).  

Science.gov (United States)

We examined the subcellular localization of ryanodine receptors (RyR) in the cardiac muscle of carp using biochemical, immunohistochemical, and electron microscopic methods and compared it with those of rats and guinea pigs. To achieve this goal, an anti-RyR antibody was newly raised against a synthetic peptide corresponding to an amino acid sequence that was conserved among all sequenced RyRs. Western blot analysis using this antibody detected a single RyR band following the SDS-PAGE of sarcoplasmic reticulum (SR) membranes from carp atrium and ventricle as well as from mammalian hearts and skeletal muscles. The carp heart band had slightly greater mobility than those of mammalian hearts. Although immunohistochemical staining showed evident striations corresponding to the Z lines in longitudinal sections of mammalian hearts, clusters of punctate staining, in contrast, were distributed ubiquitously throughout carp atrium and ventricle. Electron microscopic ...

2003-06-12

354

Studies on reactivity of coal surfaces at low temperature; Teion ni okeru sekitan hyomen no hannosei no kento  

Energy Technology Data Exchange (ETDEWEB)

With an objective to learn reactivity of coal at its surface, surfaces of oxidized coal samples were investigated. Miike coal was oxidized by using {sup 18}O2 in a closed loop system. As the reaction progresses, proportion of CO2 including isotopes increased rapidly as a result of oxidation of CO sites existing in the coal and the newly generated C{sup 18}O sites. The oxidizing reaction progressed via oxygen adsorbing sites generated near the surface, and oxygen containing groups. An FT-IR analysis estimated the depth of the oxidized layer to be 10{mu}m or less from particle surface. The oxidized coal was pulverized to see its surface condition. Functional groups introduced by the oxidation enter into the vicinity of the surface in a form to desorb as CO. CO2 is trapped in inner pores. The coal surface was observed by using an atomic force microscope. No observable openings in the pore structure were discerned on the surface before the oxidation, and the structure ...

1996-10-28

355

Structural and transport properties of illitized samples from drillhole OL-KR12 in Olkiluoto. Porosity, diffusion coefficient, permeability and tomographic imaging  

Energy Technology Data Exchange (ETDEWEB)

Six illitized samples from drillhole OL-KR12 in Olkiluoto were analyzed by helium gas methods for their diffusion coefficient, permeability and porosity. The diffusion coefficients measured varied in the range 2.1 x 10-10 - 3.5 x 10-8 m2/s, permeabilities in the range 6 x 10-21 - 5.8 x 10-16 m2, and porosities in the range 0.2 6.2%. Variations observed in these quantities were concluded to arise from the heterogeneous structure of the sample rock. A 4 mm x 4 mm x 4 mm subsample was sawed from each of the six samples for structural analysis by x-ray microtomography. The three-dimensional structure of tomographic reconstructions, and thereby that of the samples themselves, was analyzed visually, which confirmed their heterogeneity. Samples represent altered rock whose structure and thereby transport properties vary significantly depending on the local alteration history of the rock. (orig.)

2009-10-15

356

SnPc on Ag(111) investigated by STM  

Energy Technology Data Exchange (ETDEWEB)

The investigation of interfaces between thin organic films and metal surfaces is a field of highest interest because it represents the basis for future applications of organic electronic devices. In this context, phtalocyanines are of particular interest since repulsive intermolecular interaction was found recently for this group of organic molecules. Tin(II)-phtalocyanine (SnPc) is non-planar and can adsorb in two different geometries: with the Sn atom pointing downwards (Sn down) or upwards (Sn up). In our group different Pc molecules have previously been studied using several experimental techniques like SPA-LEED or XSW. Here we present STM studies of SnPc on Ag(111), taken at different coverages and temperatures, and discuss the results in the context of our previous findings. At low coverages the formation of chains can be observed for Sn down molecules while Sn up molecules tend to stay separated. This originates from a strong interaction with the substrate which leads to a ...

2010-07-01

357

Seismic migration and absorbing boundaries with a one-way wave system for heterogeneous media  

Energy Technology Data Exchange (ETDEWEB)

A first-order one-way wave system has been created based on characteristic analysis of the acoustic wave system and optimization of the dispersion relation. The authors demonstrate that this system is equivalent to a third-order scalar partial-differential equation which, for a homogeneous medium, reduces to a form similar to the 45{degree} paraxial wave equation. This system describes accurately waves propagating in a 2D heterogeneous medium at angles up to 75{degree}. The one-way wave system representing downgoing waves is used for a modified reverse time migration method. As a wavefield extrapolator in migration, the downgoing wave system propagates the reflection events backwards to their reflectors without scattering at the discontinuities in the velocity model. Hence, images with amplitudes proportional to reflectivity can be obtained from this migration technique. They present examples of the application of the new migration method to ...

1996-07-01

358

Sample preparation for nanoanalytical electron microscopy using the FIB lift-out method and low energy ion milling  

International Nuclear Information System (INIS)

Thinning specimens to electron transparency for electron microscopy analysis can be done by conventional (2-4 kV) argon ion milling or focused ion beam (FIB) lift-out techniques. Both these methods tend to leave 'mottling' visible on thin specimen areas, and this is believed to be surface damage caused by ion implantation and amorphisation. A low energy (250-500 V) Argon ion polish has been shown to greatly improve specimen quality for crystalline silicon samples. Here we investigate the preparation of technologically important materials for nanoanalysis using conventional and lift-out methods followed by a low energy polish in a GentleMill"T"M low energy ion mill. We use a low energy, low angle (6-8 deg.) ion beam to remove the surface damage from previous processing steps. We assess this method for the preparation of technologically important materials, such as steel, silicon and GaAs. For these materials the ability to create specimens from specific sites, and ...

2006-02-22

359

Regulation of human ribosomal RNA transcription.  

Science.gov (United States)

We have used a cell-free polymerase I transcription system derived from HeLa cells to study the regulation of human rRNA synthesis. Analysis of deletion mutants spanning the start site of transcription at nucleotide +1 indicates that the control region affecting initiation of human rRNA synthesis is contained within sequences from nucleotides -158 to +18. This promoter region can be subdivided into (i) a central segment of approximately 40 base pair that is required for transcription and (ii) flanking sequences that influence the efficiency of transcription in vitro. We have examined the in vitro transcriptional activity of the human extract under various conditions that are thought to modulate rRNA synthesis in vivo. Cell-free extracts prepared from HeLa cells infected with adenovirus 2 synthesize human rRNA at levels greatly decreased relative to uninfected cell extracts. By contrast, in vitro transcription of human rRNA is stimulated 2- to 3-fold by the addition ...

1983-06-01

360

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-11

361

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-01

362

Real-time 3-D SAFT-UT system evaluation and validation  

International Nuclear Information System (INIS)

SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made of this dedicated ...

1993-05-17

363

Quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and follow-up of renal osteodystrophy in dialysis patients may reduce ...

364

Purification and analysis of RNA polymerase II transcription factors by using wheat germ agglutinin affinity chromatography.  

Science.gov (United States)

We recently found that many RNA polymerase II transcription factors are modified with N-acetylglucosamine residues. These sugar moieties confer upon transcription factors an ability to bind the lectin wheat germ agglutinin. We have taken advantage of this interaction to devise a purification procedure for the "GC-box" binding transcription factor Sp1. Crude nuclear extracts are first subjected to wheat germ agglutinin affinity chromatography and then subjected to sequence-specific DNA affinity chromatography. The Sp1 protein purified by this procedure is at least 95% pure, and the overall recovery is greater than 80%. In addition to yielding larger quantities of Sp1 than conventional schemes, the new purification procedure is also simpler and more rapid. We show that wheat germ agglutinin affinity chromatography can also be used to purify the glycosylated forms of the CCAAT-binding transcription factor. Thus, wheat germ agglutinin affinity chromatography may aid the purification of ...

1989-03-01

365

Pseudocraters as indicators of ground ice on Mars  

International Nuclear Information System (INIS)

Positive identification of Martian pseudocraters would be a strong indication of past occurrence of ice at or near the surface of Mars. The basis for suggesting that small cones on Mars are pseudocraters includes: (1) small size, (2) abundant but patchy distribution on what appear to be volcanic plains, (3) presence of other features suggestive of surface or subsurface ice, (4) morphological similarities to Icelandic pseudocraters, and (5) the similarity in distribution of crater/cone diameter ratios to Icelandic pseudocraters. This last morphometric parameter may be the most important, since other possible small terrestrial volcanic analogs have very different crater/cone diameter ratio distributions. In a survey of the available high resolution Viking Orbiter imagery, abundant fields of possible pseudocraters were found. However, only a small fraction of the plains forming units imaged at high resolution were found to contain the small cones. This low discovery ...

1987-05-01

366

Oil-shale Fischer assay analysis from selected coreholes in the Piceance Creek Basin, Colorado. Data file  

Energy Technology Data Exchange (ETDEWEB)

A magnetic tape consisting of oil-shale Fischer assay data for selected well cores in the Piceance Creek Basin was prepared as a supplement to NTIS tape PB-230 607/AS. Both tapes serve as a data base for calculating oil-shale resources (Pitman, 1981). The tape is in standard IBM format and has the following specifications: EBCDIC (IBM standard), card-image, blocksize 1720 (blocked 20 to 1), record length 86, odd parity, 1,600 bpi, 9-track, no label tape. Each data file on the tape consists of records containing oil-shale analyses for one well core. The first record in a data file consists of a well-core identifier which is a three-digit number preceded by the character 'C'. The second record contains the well name and location, and the remaining records contain Fischer assay data.

1981-01-01

367

Observing Evolution in the Supergranular Length Scale During Periods of Low Solar Activity  

CERN Document Server

We present the initial results of an observational study into the variation of the dominant length-scale of quiet solar emission: supergranulation. This length-scale reflects the radiative energy in the plasma of the upper solar chromosphere and transition region at the magnetic network boundaries forming as a result of the relentless interaction of magnetic fields and convective motions of the Sun's interior. We demonstrate that a net difference of ~0.5Mm in the supergranular emission length-scale occurs when comparing observations cycle 22/23 and cycle 23/24 minima. This variation in scale is reproduced in the datasets of multiple space- and ground-based instruments and using different diagnostic measures. By means of extension, we consider the variation of the supergranular length-scale over multiple solar minima by analyzing a subset of the Mt Wilson Solar Observatory (MWO) Ca II K image record. The observations and analysis presented ...

2011-01-01

368

Non-white noise in fMRI: does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2005-01-01

369

Non-white noise in fMRI: Does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2006-01-01

370

Multiple-element eddy current probes for enhanced inspection  

Energy Technology Data Exchange (ETDEWEB)

Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe design is multiple ...

1993-07-01

371

Morphological classification and structural parameters for early-type galaxies in the Coma cluster  

CERN Document Server

We present the results of an isophotal shape analysis of three samples of galaxies in the Coma cluster. Quantitative morphology, together with structural and photometric parameters, is given for each galaxy. Special emphasis has been placed on the detailed classification of early-type galaxies. The three samples are: i) a sample of 97 early-type galaxies brighter than m_B = 17.00 falling within one degree from the center of the Coma cluster; these galaxies were observed with CCD cameras, mostly in good to excellent resolution conditions; ii) a magnitude complete sample of 107 galaxies of all morphological types down to m_B = 17.00 falling in a circular region of 50 arcmin diameter, slightly offcentered to the North-West of the cluster center; the images for this and the next sample come from digitized photographic plates; iii) a complete comparison sample of 26 galaxies of all morphological types down to m_R = 16.05 (or m_B \\simeq 17.5), also ...

1995-01-01

372

Microrheological Studies of Regenerated Silk Fibroin Solution by Video Microscopy  

CERN Document Server

We have carried out studies on the rheological properties of regenerated silk fibroin (RSF) solution using video microscopy. The degummed silk from the Bombyx mori silkworm was used to prepare RSF solution by dissolving it in calcium nitrate tetrahydrate-methanol solvent. Measurements were carried out by tracking the position of an embedded micron-sized polystyrene bead within the RSF solution through video imaging. The time dependent mean squared displacement (MSD) of the bead in solution and hence, the complex shear modulus of this solution was calculated from the bead's position information. An optical tweezer was used to transport and locate the bead at any desired site within the micro-volume of the sample, to facilitate the subsequent free-bead video analysis. We present here the results of rheological measurements of the silk polymer network in solution over a frequency range, whose upper limit is the frame capture rate of our camera, at ...

2007-01-01

373

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification images, BEKP`s, and ...

1997-12-31

374

Intracranial tuberculoma: MR imaging  

International Nuclear Information System (INIS)

MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially for brainstem tuberculomas. Nevertheless, ...

1988-11-01

375

Intense luminescence from porous ZnSe layers  

International Nuclear Information System (INIS)

We report on the possibility to prepare ZnSe porous layers with different degrees of porosity by means of electrochemical methods. The prepared porous structures were characterized using scanning electron microscopy (SEM), photoluminescence (PL) and cathodoluminescence (CL) techniques. The PL of the as-grown material and porous layers measured at low temperatures (10 K) was found to be dominated by an emission band at 2.796 eV as well as a band at 2.700 eV with several phonon replicas. The analysis of the dependence of these bands upon the excitation power density and temperature suggests that free-to-bound and respectively donor-acceptor electron transitions are responsible for the emission bands involved. The comparison of SEM and CL images taken from the same porous regions demonstrated that cathodoluminescence intensity from layers with small characteristic sizes of the porous entities (around 50 nm) is weaker than that inherent in bulk ...

376

IECEC '91; Proceedings of the 26th Intersociety Energy Conversion Engineering Conference, Boston, MA, Aug. 4-9, 1991. Vol. 2 - Aerospace power systems, conversion technologies  

International Nuclear Information System (INIS)

The present volume on energy and the environment discusses space power requirements, space power systems, space power systems hardware, space radioisotope systems, space solar arrays, space solar cells, space station power, and terrestrial applications of aerospace technology. Attention is given to NASA future space power requirements and issues, the design of a battery charger for the NASA EOS Space Platform, in situ carbon dioxide fixation on Mars, and a preliminary design update of the CRAF/Cassini Power Subsystem. Topics addressed include concentrator testing using projected images, solar power satellites and demonstraton platforms from nonterrestrial materials, a mass sensitivity analysis of lunar orbiting beam power systems, and a power-beaming-based infrastructure for space power. Also discussed are fiber-optic sensors for aerospace electrical measurements, the preliminary design of a mobile lunar power supply, advanced power systems for ...

1991-08-03

377

Hepatobiliary scintigraphy in current pediatric practice  

Energy Technology Data Exchange (ETDEWEB)

Hepatobiliary scintigraphy is the only non-invasive technique providing real-time assessment of hepatocytes function and bile progression from the liver to the intestine; for this reason it is of great importance in the study of jaundice and many other disorders of the liver and the biliary tract in children. Ultrasonography is the initial method of evaluating the intra- and extrahepatic bile ducts dilatation: the differential diagnosis between biliary atresia and neonatal hepatitis cannot however be done without hepatobiliary scintigraphy. Cystic fibrosis patients also require hepatobiliary scintigraphy; liver and biliary tract disease can really occur independently of the underlying disease severity and the presence of steatorrhoea. Hepatobiliary imaging in children who have undergone liver transplantation is of major importance; it can assess vascularity, parenchymal function biliary drainage, possible presence of a bile leak and obstruction; it has very good ...

1998-06-01

378

Evaluation of craniosynostosis surgery. Technetium-99m-HMPAO SPECT cerebral blood flow study in children with craniosynostosis  

International Nuclear Information System (INIS)

Premature fusion of multiple cranial sutures has been associated with increased intracranial pressure and the potential for mental impairment. Isolated craniosynostosis, however, is considered a benign condition primarily reconstructed for aesthetic purposes. A comparative analysis, to assess the differences between pre- and post operatory cerebral perfusion of patients who underwent surgery for simple cranisynostosis, was performed using single positron emission computed tomography ''SPECT'' Images. Cerebral blood flow studies were performed using "9"9"mTc-HMPAO SPECT in children with simple cranisynotoses. The subjects were 8 children with craniosynostosis (age, 2 months-9 years). Preoperative revealed regional hypovascularity in the cerebral hemisphere in 5 cases (62%). In 6 patients the cerebral blood flow normalized or increased after craniofacial reconstruction. We demonstrated the presence of regional hypovascularity in the cerebral ...

1998-09-01

379

Electrochemical properties of Cu{sub 2}O/Cu composite particles prepared by a novel and facile method  

Energy Technology Data Exchange (ETDEWEB)

In this study, Cu{sub 2}O/Cu composite particles were synthesized using an innovative chemical reduction method without any template and surfactant. X-ray diffraction (XRD) analysis revealed that the product mainly consisted of Cu{sub 2}O phase coexisting with a Cu phase. FE-SEM images showed that the octahedral shaped particles were Cu{sub 2}O. The electrochemical performance of the Cu{sub 2}O/Cu particles was investigated with regards to the working electrode material in alkaline solution. The particles had a maximum discharge capacity of 222.9 mAh/g at a discharge current density of 60 mA/g and a high value of 109.1 mAh/g after 50 charge-discharge cycles. Cyclic voltammetry revealed that the reaction between Cu{sub 2}O and Cu is the major electrochemical reaction during the charging and discharging process. Electrochemical impedance spectroscopy revealed that the formation of Cu{sub 2}O on the surface of Cu particles increased the contact ...

2010-07-01

380

Effects of extreme pressure additive chemistry on rolling element bearing surface durability  

Energy Technology Data Exchange (ETDEWEB)

Lubricant additives have been known to affect rolling element bearing surface durability for many years. Tapered roller bearings were used in fatigue testing of lubricants formulated with gear oil type additive systems. These systems have sulfur- and phosphoruscontaining compounds used for gear protection as well as bearing lubrication. Several variations of a commercially available base additive formulation were tested having modified sulfur components. The variations represent a range of ''active'' extreme pressure (EP) chemistries. The bearing fatigue test results were compared with respect to EP formulation and test conditions. Inner ring near-surface material in selected test bearings was evaluated on two scales: the micrometer scale using optical metallography and the nanometer scale using transmission electron microscopy (TEM). Focused-ion beam (FIB) techniques were used for TEM specimen preparation. Imaging and chemical ...

2007-08-01

381

Ectopic expression of wild-type or a dominant-negative mutant of transcription factor NTF-1 disrupts normal Drosophila development.  

Science.gov (United States)

The Drosophila melanogaster tissue-specific transcription factor NTF-1 was originally identified in vitro as a protein that could bind to and activate transcription from the Dopa decarboxylase (Ddc) gene. A structure-function analysis of NTF-1 led to the identification of a discrete amino-terminal activation domain. Here, we report that an NTF-1 mutant lacking the activation domain acts as a trans-dominant inhibitor of NTF-1 activation in tissue culture cells by forming inactive heterodimers with the full-length protein. Ectopically expressing this dominant-negative protein or the full-length protein in developing Drosophila embryos leads to dire developmental consequences. Overexpressing the trans-dominant NTF-1 leads to lethality, while overexpressing full-length NTF-1 results in both lethality and morphogenetic defects. Our results suggest that both the activity and the regulation of NTF-1 are critical for viability and proper development of the ...

1993-11-15

382

EVIDENCE FOR DELAYED MASSIVE STAR FORMATION IN THE M17 PROTO-OB ASSOCIATION  

International Nuclear Information System (INIS)

Through analysis of archival images and photometry from the Spitzer GLIMPSE and MIPSGAL surveys combined with Two Micron All Sky Survey and MSX data, we have identified 488 candidate young stellar objects (YSOs) in the giant molecular cloud M17 SWex, which extends #approx#50 pc southwest from the prominent Galactic H II region M17. Our sample includes >200 YSOs with masses >3 M _s_u_n that will become B-type stars on the main sequence. Extrapolating over the stellar initial mass function (IMF), we find that M17 SWex contains >1.3 x 10"4 young stars, representing a proto-OB association. The YSO mass function is significantly steeper than the Salpeter IMF, and early O stars are conspicuously absent from M17 SWex. Assuming M17 SWex will form an OB association with a Salpeter IMF, these results reveal the combined effects of (1) more rapid circumstellar disk evolution in more massive YSOs and (2) delayed onset of massive star formation.

2010-05-10

383

Direct sub-nanometer scale electron microscopy analysis of anion incorporation to self-ordered anodic alumina layers  

International Nuclear Information System (INIS)

Research highlights: #-># Morphological and chemical characterization at atomic scale of porous alumina layers anodised in ordered regimes. #-># Characterization based on the use of FEG-SEM, STEM-HAADF, STEM-EELS and STEM-X-EDS. #-># Nanoscale distribution of P-, C- and S-bearing species in the pore wall. - Abstract: Ordered porous alumina layers prepared by two-step anodising in phosphoric, oxalic and sulphuric acids have been characterized at sub-nanometer scale using electron microscopy techniques. FEG-SEM and STEM-HAADF images allowed estimating the pore size, cell wall and pore wall thicknesses of the layers. Nanoanalytical characterization has been performed by STEM-EELS and STEM-X-EDS. Detailed features of the spatial distribution of anions in the pore wall of the films have been obtained. Maximum concentration of P-species occurs, approximately, at the middle of the pore wall; adjacent to the pore for C-species, whereas the distribution of ...

2010-11-01

384

Detection of constitutive heterodimerization of the integrin Mac-1 subunits by fluorescence resonance energy transfer in living cells  

International Nuclear Information System (INIS)

Macrophage differentiation antigen associated with complement three receptor function (Mac-1) belongs to #beta#_2 subfamily of integrins that mediate important cell-cell and cell-extracellular matrix interactions. Biochemical studies have indicated that Mac-1 is a constitutive heterodimer in vitro. Here, we detected the heterodimerization of Mac-1 subunits in living cells by means of two fluorescence resonance energy transfer (FRET) techniques (fluorescence microscopy and fluorescence spectroscopy) and our results demonstrated that there is constitutive heterodimerization of the Mac-1 subunits and this constitutive heterodimerization of the Mac-1 subunits is cell-type independent. Through FRET imaging, we found that heterodimers of Mac-1 mainly localized in plasma membrane, perinuclear, and Golgi area in living cells. Furthermore, through analysis of the estimated physical distances between cyan fluorescent protein (CFP) and yellow fluorescent ...

2006-08-04

385

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

386

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

387

Comparison of the quality of the chest film between digital radiography and conventional high kV radiography  

International Nuclear Information System (INIS)

Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct ...

2003-02-01

388

Combined Scanning Electron Microscope and Micro-InfraRed measurements on Interplanetary Dust Particles  

CERN Document Server

Laboratory characterization of Interplanetary Dust Particles (IDPs) collected in the lower stratosphere represents a concrete analysis of cosmic dust properties which played a fundamental role in the origin and evolution of Solar System. The IDPs were characterized by Field Emission Scanning Electron Microscope (FESEM) analyses and by InfraRed (IR) micro-spectroscopy. We present the FESEM images of six IDPs: three smooth grains, two porous and one a compact sphere. We also show the results of micro-IR transmission measurements on four IDPs that allowed us to identify their spectral class according to the criteria defined by Sandford and Walker. Only three of the analyzed particles show IR transmission spectra with a dominant "silicate absorption feature" so that they could be assigned to the three IR spectral classes: one has been classified as "amorphous olivine", one appears to be a mixture of "olivines" and "pyroxenes" and one belongs to the ...

2007-01-01

389

Automated segmentation and quantitative characterization of radiodense tissue in digitized mammograms  

International Nuclear Information System (INIS)

Mammography has emerged as a reliable non-invasive technique for the early detection of breast cancer--the second leading cause of cancer-related mortality among American women. The radiographic appearance of the female breast consists of radiolucent (dark) regions due to fat and radiodense (light) regions due to connective and epithelial tissue. The amount of radiodense tissue can be used as a marker for predicting breast cancer risk. This paper presents the development of an algorithm for estimating the percentage of radiodense tissue in a digitized mammogram. The technique involves determining a dynamic threshold for segmenting radiodense indications in mammograms. Both the mammographic image and the threshold are modeled as Gaussian random variables. This work is intended to support a concurrent study at the Fox Chase Cancer Center (FCCC) exploring the association between dietary patterns and breast cancer risk. Mammograms have been obtained from an existing ...

2002-05-25

390

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...

1998-02-01

391

An objective indicator for two-phase flow pattern transition  

Energy Technology Data Exchange (ETDEWEB)

This work concerns the development of a methodology the objective of which is to characterize and diagnose two-phase flow regime transitions. The approach is based on the fundamental assumption that a transition flow is less stationary than a flow with an established regime. During the first time, the efforts focused on: (1) the design and construction of an experimental loop, allowing to reproduce the main horizontal two-phase flow patterns, in a stable and controlled way; (2) the design and construction of an electrical impedance probe, providing an imaged information of the spatial phase distribution in the pipe; and (3) the systematic study of the joint time-frequency and time-scale analysis methods, which permitted to define an adequate parameter quantifying the unstationarity degree. During the second time, in order to verify the fundamental assumption, a series of experiments were conducted, the objective of which was to demonstrate the ...

1998-08-01

392

An objective indicator for two-phase flow pattern transition  

International Nuclear Information System (INIS)

This work concerns the development of a methodology the objective of which is to characterize and diagnose two-phase flow regime transitions. The approach is based on the fundamental assumption that a transition flow is less stationary than a flow with an established regime. During the first time, the efforts focused on: (1) the design and construction of an experimental loop, allowing to reproduce the main horizontal two-phase flow patterns, in a stable and controlled way; (2) the design and construction of an electrical impedance probe, providing an imaged information of the spatial phase distribution in the pipe; and (3) the systematic study of the joint time-frequency and time-scale analysis methods, which permitted to define an adequate parameter quantifying the unstationarity degree. During the second time, in order to verify the fundamental assumption, a series of experiments were conducted, the objective of which was to demonstrate the ...

1998-08-01

393

An investigation of the capacitance dispersion on the fractal carbon electrode with edge and basal orientations  

Energy Technology Data Exchange (ETDEWEB)

Capacitance dispersion on the fractal carbon electrode with edge and basal orientations was investigated using atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and a.c.-impedance spectroscopy. For this purpose, four types of as-received pyrolytic graphite electrode, as-received, mechanically polished, and as-activated glassy carbon electrodes were prepared with different surface irregularities and amounts of edge orientations. The apparent self-similar fractal dimensions of the carbon electrodes were determined from the analyses of AFM images based upon triangulation method. The amounts of edge orientations on the surface of the carbon electrodes were qualitatively estimated from the XPS analysis of surface acidic functional groups that were preferably formed on the edge planes by the heat treatment of the carbon electrodes. The values of the constant phase element exponent {alpha} determined from the apparent self-similar ...

2003-10-15

394

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak luminosity of CXOGC J174540.0-290031 was >2e36 erg/s. We suggest that the ...

2005-01-01

395

Soft tissue manifestations of early rheumatic disease. Imaging with MRI; Fruehmanifestationen rheumatischer Gelenkerkrankungen an den Weichgewebestrukturen der Hand. Nachweis mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema ...

2006-08-15

396

Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 13. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results obtained during Stage 13 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. A brief proposal for the continuation of this program in Stage 14 is also given at the end of the report. The program executed in Stage 13 consists of three parts and the work performed in each part is summarized below. 1. Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR). Although the original goal of the investigations of the MSR in Stage 13 was to calculate the neutron noise induced by the fluctuations of the fuel temperature, the study, solution and interpretation of the static problem, as well as to define an approximate version of the point kinetic approximation was necessary to perform. As it turned out, these tasks in themselves were more involved, and also very edifying, to solve. Hence, in this report, we confine the study of the reactor physics of ...

2008-06-15

397

In vitro MRI of brain development  

International Nuclear Information System (INIS)

In this review, we demonstrate the developmental appearance, structural features, and reorganization of transient cerebral zones and structures in the human fetal brain using a correlative histological and MRI analysis. The analysis of postmortem aldehyde-fixed specimens (age range: 10 postovulatory weeks to term) revealed that, at 10 postovulatory weeks, the cerebral wall already has a trilaminar appearance and consists of: (1) a ventricular zone of high cell-packing density; (2) an intermediate zone; (3) the cortical plate (in a stage of primary consolidation) with high MRI signal intensity. The anlage of the hippocampus is present as a prominent bulging in the thin limbic telencephalon. The early fetal telencephalon impar also contains the first commissural fibers and fornix bundles in the septal area. The ganglionic eminence is clearly visible as an expanded continuation of the proliferative ventricular zone. The basal ganglia showed an ...

2006-02-01

398

Statistical Analysis of Designed Experiments  

CERN Document Server

Statistical Analysis of Designed Experiments

2010-01-01

399

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...

2003-01-01

400

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...

2006-08-01

401

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

402

Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image  

Energy Technology Data Exchange (ETDEWEB)

In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...

1985-01-01

403

Direct digital radiography vs conventional radiography of thoracic spine: a comparative study  

International Nuclear Information System (INIS)

Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...

2005-09-01

404

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...

2008-12-15

407

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

408

Tracheal images using energy subtraction Fuji computed radiography  

International Nuclear Information System (INIS)

Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).

1985-01-01

409

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

410

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

411

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

412

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

413

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

414

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...

2007-08-21

415

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...

2007-08-21

416

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-08-01

417

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-01-01

418

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

419

Verification of MLC based real-time tumor tracking using an electronic portal imaging device  

UK PubMed Central (United Kingdom)

Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available

2010-06-01

420

Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms  

International Nuclear Information System (INIS)

The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...

2007-07-01

421

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

422

Subject-specific, multiscale simulation of electrophysiology: a software pipeline for image-based models and application examples  

UK PubMed Central (United Kingdom)

Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available

2009-06-13

423

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

424

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

Energy Technology Data Exchange (ETDEWEB)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...

1987-03-01

425

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

International Nuclear Information System (INIS)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...

1987-01-01

426

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

427

Signal and imaging sciences workshop proceedings  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.

1997-11-01

428

SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY  

UK PubMed Central (United Kingdom)

This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available

2009-08-07

429

Romantic and Sexual Relationships, Body Image, and Fertility in Adolescent and Young Adult Testicular Cancer Survivors: A Review of the Literature  

UK PubMed Central (United Kingdom)

This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available

2010-08-01

430

Retinal Fundus Image Registration via Vascular Structure Graph Matching  

UK PubMed Central (United Kingdom)

Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available

2010-01-01

431

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

432

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

433

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

434

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

435

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...

2008-04-15

436

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

437

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

438

Monitoring of NK-Cell Immunotherapy using non-invasive Imaging Modalities  

UK PubMed Central (United Kingdom)

Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available

2010-08-01

439

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

440

JAtlasView: a Java atlas-viewer for browsing biomedical 3D images and atlases  

UK PubMed Central (United Kingdom)

BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available

441

In vivo imaging of neutrotransmitter functions in brain, heart and tumors  

Energy Technology Data Exchange (ETDEWEB)

This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.

1991-01-01

442

Human Lymphatic Architecture and Dynamic Transport Imaged Using Near-infrared Fluorescence12  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available

443

High Contrast Near-infrared Polarized Reflectance Images of Demineralization on Tooth Buccal and Occlusal Surfaces at ?=1310-nm  

UK PubMed Central (United Kingdom)

Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available

2009-03-01

444

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

445

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

446

Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope  

UK PubMed Central (United Kingdom)

The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available

1999-01-01

447

Dual-channel imaging system for singlet oxygen and photosensitizer for PDT  

UK PubMed Central (United Kingdom)

A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available

448

Doppler imaging using spectrally-encoded endoscopy  

UK PubMed Central (United Kingdom)

The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available

2008-09-15

449

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-09-01

450

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-01-01

451

Design and Implementation of an Open Source Indexing Solution for a Large Set of Radiological Reports and Images  

UK PubMed Central (United Kingdom)

This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available

2007-11-01

452

Correspondence of Ultrasound Elasticity Imaging to Direct Mechanical Measurement in Aging DVT in Rats  

UK PubMed Central (United Kingdom)

Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available

2005-10-01

453

Closing the loop in cortically-coupled computer vision: a brain-computer interface for searching image databases.  

Science.gov (United States)

We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...

2011-05-12

454

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

455

Challenges of functional imaging research of pain in children  

UK PubMed Central (United Kingdom)

Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available

456

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

457

Antisense imaging of gene expression in the brain in vivo  

UK PubMed Central (United Kingdom)

Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available

2000-12-19

458

A high-speed network for cardiac image review.  

UK PubMed Central (United Kingdom)

A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available

1994-01-01

459

A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate  

UK PubMed Central (United Kingdom)

BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available

2010-11-01

460

Focus ion beam preparation of transmission electron microscope sample in polymer clay nano composite  

International Nuclear Information System (INIS)

This paper deals with preparation of PE clay nano composite specimen for transmission electron microscopy (TEM) and studying the difference between dispersion of clay in low density polyethylene using poly(hydrogen methyl siloxane) (PHMS) as coupling agent and untreated one. Argon ion milling is the conventional means by which film sections are thinned to electron transparency for TEM analysis, but this technique exhibits significant problems. In particular, selective thinning and imaging of sub-micrometer inclusions during sample milling are highly problematic. We have achieved successful results using the focused ion beam (FIB) lift-out technique, which utilizes a 30 kV Ga"+ ion beam to extract electron transparent specimens with nanometer scale precision. Using this procedure, we have prepared a number of thin film materials representing a range of structures and compositions for TEM analysis. We believe that FIB milling ...

2006-01-01

461

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on long-lived radioactive isotopes including ...

462

Efficient, intelligent systems for navigating the biological literature. Final report, September 15, 1993--September 14, 1996  

Energy Technology Data Exchange (ETDEWEB)

The biological literature is huge and increasingly moving to electronic form. By developing a variety of new techniques, it should be possible to take advantage of this huge and growing electronic store. Computers should allow one to use the literature with greater efficiency and insight to disseminate information and to advance scientific understanding. Though there is a great deal of research and development effort focused on electronic text, e.g., the Digital Libraries initiative, little attention has been paid to the diagrammatic content of documents. However, it is common knowledge among biologists, and scientists in general, that the figures in documents are of critical importance. Little work has been done to develop principles and systems for analyzing, representing, and indexing and searching the diagrammatic content of electronic documents. This has been the main thrust of this research project. The primary work in the world on the analysis of graphics in ...

1997-04-04

463

Development of an efficient parallel FEM analysis program for large structural problems over several millions of DOF  

International Nuclear Information System (INIS)

In order to predict or to evaluate the structural reliability of a variety of nuclear components under actual changing operating conditions, it is necessary to take the detailed geometrical features of components into consideration on one hand, and thermo-mechanical loading conditions with space and time variations during the lifetime, on the other hand. This consideration leads the authors to develop a super large-scale structural analysis program based on a parallel computational FEM with a variable scale of PC cluster architecture, whose prototype system is presented in a companion paper in this Symposium. Development of the PC cluster technology is one of the most important subjects in large-scale structural simulation, reducing computer costs and thus making simulation more acceptable to the engineering community. This paper presents the developmental status of the parallel FEM solver, demonstrating computational capabilities with three dimensional effects ...

2000-09-01

464

Cloning of Drosophila transcription factor Adf-1 reveals homology to Myb oncoproteins.  

Science.gov (United States)

The Drosophila sequence-specific DNA binding protein, Adf-1, is capable of activating transcription of the alcohol dehydrogenase gene, Adh, and is implicated in the transcriptional control of other developmentally regulated genes. We have cloned the cDNA encoding Adf-1 by generating specific DNA probes deduced from partial amino acid sequence of the protein. Several cDNA clones encoding an extended open reading frame were isolated from a phage lambda library. The complete amino acid sequence of Adf-1 deduced from the longest cDNA reveals structural similarities to the putative helix-turn-helix DNA binding motif of Myb and Myb-related proteins. DNA sequence analysis of genomic clones and Northern blot analysis of mRNA suggest that Adf-1 is a single-copy gene encoding a 1.9-kb transcript. Purified recombinant Adf-1 expressed in Escherichia coli binds specifically to Adf-1 recognition sites and activates transcription of a synthetic Adh promoter ...

1992-01-15

465

Characterization of pore structure in cement-based materials using pressurization-depressurization cycling mercury intrusion porosimetry (PDC-MIP)  

International Nuclear Information System (INIS)

Numerous mercury intrusion porosimetry (MIP) studies have been carried out to investigate the pore structure in cement-based materials. However, the standard MIP often results in an underestimation of large pores and an overestimation of small pores because of its intrinsic limitation. In this paper, an innovative MIP method is developed in order to provide a more accurate estimation of pore size distribution. The new MIP measurements are conducted following a unique mercury intrusion procedure, in which the applied pressure is increased from the minimum to the maximum by repeating pressurization-depressurization cycles instead of a continuous pressurization followed by a continuous depressurization. Accordingly, this method is called pressurization-depressurization cycling MIP (PDC-MIP). By following the PDC-MIP testing sequence, the volumes of the throat pores and the corresponding ink-bottle pores can be determined at every pore size. These values are used to calculate pore size ...

2010-07-01

466

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass ...

2006-12-21

467

An Assessment of the Detection of Highly Enriched Uranium and its Use in an Improvised Nuclear Device using the Monte Carlo Computer Code MCNP-5  

Science.gov (United States)

In 2002 and again in 2003, an investigative journalist unit at ABC News transported a 6.8 kilogram metallic slug of depleted uranium (DU) via shipping container from Istanbul, Turkey to Brooklyn, NY and from Jakarta, Indonesia to Long Beach, CA. Targeted inspection of these shipping containers by Department of Homeland Security (DHS) personnel, included the use of gamma-ray imaging, portal monitors and hand-held radiation detectors, did not uncover the hidden DU. Monte Carlo analysis of the gamma-ray intensity and spectrum of a DU slug and one consisting of highly-enriched uranium (HEU) showed that DU was a proper surrogate for testing the ability of DHS to detect the illicit transport of HEU. Our analysis using MCNP-5 illustrated the ease of fully shielding an HEU sample to avoid detection. The assembly of an Improvised Nuclear Device (IND) -- a crude atomic bomb -- from sub-critical pieces of HEU metal was then examined ...

2007-04-01

468

metadata, images and captions. - The Gateway to Astronaut ...  

Science.gov (United States)

... the Zaire is not an efficient transportation link because of many rapids and falls to negotiate between Kinshasa and the port city of Matadi. ...

469

Visible Earth: Food Additives  

Science.gov (United States)

Feb 25, 2008 ... NASA's Visible Earth catalog of NASA images and animations of our home planet.

470

Using Acoustic Tomography to Monitor Deep Ocean Currents ...  

Science.gov (United States)

... 2009. Copyright belongs to the Marine Technology Society., The original document contains color images. 14. ABSTRACT ...

2010-06-01

471

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

472

Three-dimensional image display of brain tumor utilizing a modified voxel method  

Energy Technology Data Exchange (ETDEWEB)

The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.

1988-08-01

475

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

477

Radioiodine benzodiazepines as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1992-03-17

478

Radioiodine benzodiazepines as brain imaging agents  

International Nuclear Information System (INIS)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1990-06-25

481

Non-traumatic thoracic emergencies: imaging and treatment of thoracic fluid collections (including pneumothorax)  

International Nuclear Information System (INIS)

Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)

2002-08-01

482

MER-DIMES : a planetary landing application of computer vision  

Science.gov (United States)

During the Mars Exploration Rovers (MER) landings, the Descent Image Motion Estimation System

2005-01-01

485

Incidental discovery of asplenia syndrome, with situs inversus and a normal heart by radionuclide biliary imaging. A case report  

International Nuclear Information System (INIS)

/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.

486

Imaging characterization of carbon nanotube tips modified using a focused ion beam  

International Nuclear Information System (INIS)

A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.

2007-06-15

487

Image Descriptors for Displays  

Science.gov (United States)

... 44 2. Luminance Power Spectral Density Measurements ..... 44 ... 50 4. Chrominance Power Spectral Density Measurements ..... 53 ...

1977-02-01

488

Iao: The New Adaptive Optics Visible Imaging and ...  

Science.gov (United States)

... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...

2008-09-01

489

Growth, Characterization and Device Development in ...  

Science.gov (United States)

... eV. In some instances the spontaneous radiation from a free electron laser system was employed to obtain images. The ...

1998-03-01

490

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

491

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

492

Development of ARIES Baker-Nunn camera to a wide-field Imaging Telescope with CCD  

CERN Document Server

ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.

2009-01-01

493

Detection and Diagnosis of Oral Neoplasia with an Optical ...  

Science.gov (United States)

... Thus, 0CM provides the potential to image epithelial tissue with the subcellular resolution needed to assess the pathologic state of tissue. ...

494

DVRPC 2010 Digital Orthoimagery - Mr.SID County Mosaics  

Science.gov (United States)

... image overlap between adjacent tiles. Orthoimagery processed by BAE Systems....

495

Cerebral angiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).

1985-01-01

496

Burned Timber Canyon  

Science.gov (United States)

The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....

498

A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber  

Science.gov (United States)

... In this paper research aimed at creating a computer vision system to power such an optimal edging and ... ...