We report on studies of field-effect transistor (FET) and transparent thin-film transistor (TFT) devices based on lightly Ta-doped SnO2 nano-wires. The nanowire-based devices exhibit uniform characteristics with average field-effect mobilities exceeding 100 cm2/V x s. Prototype nano-wire-based TFT (NW-TFT) devices on glass substrates showed excellent optical transparency and transistor performance in terms of transconductance, bias voltage range, and on/off ratio. High on-currents and field-effect mobilities were obtained from the NW-TFT devices even at low nanowire coverage. The SnO2 nanowire-based TFT approach offers a number of desirable properties such as low growth cost, high electron mobility, and optical transparency and low operation voltage, and may lead to large-scale applications of transparent electronics on ...
Abstract: We report for the selective-area chemical synthesis of semiconductor single-crystal organic nanowires of silver-tetracyanoquinodimethane (Ag-TCNQ). Straight and smooth Ag-TCNQ nanowires can be produced and patterned on micrometer and nanometer scale on silicon substrates covered with a thin layer of Ag film through the reaction of TCNQ and Ag in a simple gas-solid chemical reaction process. Ag-TCNQ nanowires are characterized by UV-vis, IR and Raman spectroscopy, respectively. The Ag-TCNQ nanowires grows preferentially along the [100] direction of strong - stacking of Ag-TCNQ molecules. Nanodevices based on these nanowires are fabricated using focus ion beam (FIB) technique. Electrical properties are characterized and I-V hysteresis is observed, which shows memory effect with electrical switching of three orders on-off ratio. These nanowires could be ...
Arrays of CdS:Mn{sup 2+}:Cu{sup +} micro- and nanowires grown in polycarbonate ion-track templates exhibit photoluminescence in the spectral domain ranging from 500 to 800 nm at room temperature. A comparison with similar CdS and CdS:Mn{sup 2+} wire arrays is presented. The individual contributions to the emission spectra of Cu{sup +} and Mn{sup 2+} ions in the CdS matrix are explained using their energy level schemes. Also SEM, EDX and EPR data are given for these wires. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
Arrays of CdS:Mn"2"+:Cu"+ micro- and nanowires grown in polycarbonate ion-track templates exhibit photoluminescence in the spectral domain ranging from 500 to 800 nm at room temperature. A comparison with similar CdS and CdS:Mn"2"+ wire arrays is presented. The individual contributions to the emission spectra of Cu"+ and Mn"2"+ ions in the CdS matrix are explained using their energy level schemes. Also SEM, EDX and EPR data are given for these wires. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO_2 substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a focused ion beam ...
The combination of large thickness ($>3$ $\\mu$m), large--area uniformity (75 mm diameter), high growth rate (up to 0.4 $\\mu$m/min) in assemblies of complex--shaped nanowires on lithographically defined patterns has been achieved for the first time. The nanoscale and the microscale have thus been blended together in sculptured thin films with transverse architectures. SiO$_x$ ($x\\approx 2$) nanowires were grown by electron--beam evaporation onto silicon substrates both with and without photoresist lines (1--D arrays) and checkerboard (2--D arrays) patterns. Atomic self--shadowing due to oblique--angle deposition enables the nanowires to grow continuously, to change direction abruptly, and to maintain constant cross--sectional diameter. The selective growth of nanowire assemblies on the top surfaces of both 1--D and 2--D arrays can be ...
Highly water-repellent surfaces have been prepared from arrayednanowires of zinc oxide (ZnO) by a treatment with stearic acid. The layers are electrochemically deposited on a nanocrystalline seed layer from an oxygenated aqueous zinc chloride solution. An advancing contact angle (CA) as high as 176{sup 0} is obtained with a very small hysteresis {approx}1{sup 0}. These results, supplemented by infrared spectroscopy, show that the stearic acid forms a very well-packed self-assembled monolayer. The CA measurements show a very good stability of the treated surface even when exposed to harsh conditions or long-term ambient illumination.
We present a new approach for growing Si nanowires directly from a silicon substrate, without the use of a metal catalyst, silicon vapor or CVD gasses. The growth can be performed in a furnace type configuration at moderate temperatures or in localized regions by resistive heating. Since the silicon wires grow directly from the silicon substrate, they do not need to be manipulated nor aligned for subsequent applications. Wires in the 20-50 nm diameter range with lengths over 80 ?m can be grown by this technique. We have studied the effects of various growth parameters, including temperature, substrate orientation, initial sample cleaning and carrier gasses. Results indicate that most important parameters in the growth of the nanowires are the surface cleaning, the temperature and the type of carrier gas used. A model is proposed, which involves an oxide catalyst for the process, with the growth of the nanowires enabled by a ...
Coaxial nanocables with a single-crystalline zinc telluride (ZnTe) nanowire core and an amorphous silicon oxide (SiO_x) shell have been synthesized via a simple one-step chemical vapor deposition (CVD) method on gold-decorated silicon substrates. The single-crystal ZnTe nanowire core is in zinc-blende structure along the [111] direction, while the uniform SiO_x shell fully covers the core with no observable pin-hole or crack. Formation mechanisms of the ZnTe-SiO_x nanocables are discussed. The ZnTe nanowire core shows p-type electrical properties while the SiO_x shell acts as an effective insulating layer. The ZnTe-SiO_x nanocables may have potential applications in nanoscale devices, such as p-type FETs and nanosensors.
ObjectivesFor thermoelectricity both low thermal conductivity and high electrical conductivity are required. High electrical conductivity should be established via a high carriers concentration and a high mobility.~%~The aim of this feasibility study is to investigate a method of modulation doping of Si nanowires in order to generate high carrier concentrations without the need for impurity doping, thus retaining high mobilities.~%~~%~The objectives are (in chronological order):~%~- reduction of the wire [continued...]DescriptionIn recent years, the increasing dependence of society on fossil fuels for socio-economical development has become a cause of great concern. The possibility of a reduced availability of fossil fuels, and the effect of these fuels on climate change, have encouraged research into alternative energy sources. Many of these alternatives are old ideas, implemented using modern techniques. This proposal plans to investigate the ...
The controlled growth of nanowires (NWs) with dimensions comparable to the Fermi wavelengths of the charge carriers allows fundamental investigations of quantum confinement phenomena. Here, we present studies of proximity-induced superconductivity in undoped Ge/Si core/shell NW heterostructures contacted by superconducting leads. By using a top gate electrode to modulate the carrier density in the NW, the critical supercurrent can be tuned from zero to greater than 100 nA. Furthermore, discrete sub-bands form in the NW due to confinement in the radial direction, which results in stepwise increases in the critical current as a function of gate voltage. Transport measurements on these superconductor-NW-superconductor devices reveal high-order (n = 25) resonant multiple Andreev reflections, indicating that the NW channel is smooth and the charge transport is highly coherent. The ability to create and control coherent superconducting ordered states ...
Analysis of steady-state and transient photoconductivity measurements at room temperature performed on c-axis oriented GaN nanowires yielded estimates of free carrier concentration, drift mobility, surface band bending, and surface capture coefficient for electrons. Samples grown (unintentionally n-type) by nitrogen-plasma-assisted molecular beam epitaxy primarily from two separate growth runs were examined. The results revealed carrier concentration in the range of (3-6)x10"1"6 cm"-"3 for one growth run, roughly 5x10"1"4-1x10"1"5 cm"-"3 for the second, and drift mobility in the range of 500-700 cm"2/(V s) for both. Nanowires were dispersed onto insulating substrates and contacted forming single-wire, two-terminal structures with typical electrode gaps of #approx =#3-5 #mu#m. When biased at 1 V bias and illuminated at 360 nm (3.6 mW/cm"2) the thinner (#approx =#100 nm diameter) nanowires with the higher background doping ...
Nano-wirearrays of Niobium were produced by small angle sputtering on facetted sapphire, using the self shadowing effect of the facets. A wire width of about 80 nm was adjusted, the mean (maximum) wire height was about 20 nm (30 nm), the length can be in the cm range. Meander-film morphologies of 20 nm mean (26 nm maximum) thickness were produced by conventional sputtering onto smooth sapphire substrates at elevated temperatures. The morphology of the wires was investigated with atomic force microscopy (AFM), using contact mode. Meander-films were studied by scanning tunnelling microscopy (STM). Hydrogen loading was performed by instantaneously increasing the hydrogen gas pressure above the solubility limit. Thus, an elongated hydride could be monitored in an about 30 nm thick wire. STM studies on meander-films show the presence of cylindrical hydrides. Local out-of-plane and in-plane expansion can be explained by the formation of hydrides, ...
Field Programmable Gate Arrays (FPGAs) are being used in space applications because of attractive attributes: good density, moderate speed, low cost, and quick turn-around time. However, these devices are susceptible to Single Event Upsets (SEUs). An approach using triple modular redundancy (TMR) and feedback was developed for flip-flop hardening in these devices. Test data showed excellent results for this circuit topology. Total dose and Single Event Effect (SEE) testing have been performed on recently released technologies. Failures are analyzed and test methodology is discussed.
Functionalizing of single molecules on surfaces has manifested great potential for bottom-up construction of complex devices on a molecular scale. We discuss the growth mechanism for the initial layers...Full Text Available
Room temperature continuous wave operation of red ([lambda][sub 0] [approximately] 660 nm) vertical cavity surface emitting laser arrays is reported. The 1 [times] 64 arrays have a pitch of 100 [mu]m with device diameters of 15 [mu]m with device diameters of 15 [mu]m. Grown by metalorganic vapor phase epitaxy, the devices consist of an AlGaInP strained quantum well optical cavity active region surrounded by AlGaAs distributed Bragg reflectors (DBR's). The top coupling DBR includes a partial dielectric stack, deposited after implanted device fabrication. All 64 devices operation simultaneously with peak output powers >0.45 mW, threshold current <1.5 mA, and threshold voltages [<=] 2.7 V. The differential quantum efficiencies exceed 10%.
Nanowires, films, and membranes comprising ordered porous manganese oxide-based octahedral molecular sieves, and methods of making, are disclosed. A single crystal ultra-long nanowire includes an ordered porous manganese oxide-based octahedral molecular sieve, and has an average length greater than about 10 micrometers and an average diameter of about 5 nanometers to about 100 nanometers. A film comprises a microporous network comprising a plurality of single crystal nanowires in the form of a layer, wherein a plurality of layers is stacked on a surface of a substrate, wherein the nanowires of each layer are substantially axially aligned. A free standing membrane comprises a microporous network comprising a plurality of single crystal nanowires in the form of a layer, wherein a plurality of layers is aggregately stacked, and wherein the nanowires of each layer ...
Two new identical insertion devices have been designed for the Daresbury SRS. They are 2T permanent-magnet multipole wigglers that will provide high flux in the X-ray region. This paper describes the magnetic and mechanical design of the arrays of steel pole pieces and permanent-magnet blocks. Also given is the engineering design of the support structure that will cope with the very large forces present while maintaining high levels of precision in gap setting and parallelism. The engineering design has been fully assessed using finite-element techniques to predict the deflections of critical parts of the structure. These two devices are due to be installed into the SRS by the end of 1998.
The Energy crisis happens to be one of the greatest challenges we are facing today. In this view, much effort has been made in developing new, cost effective, environmentally friendly energy conversion and storage devices. The performance of such devices is fundamentally related to material properties. Hence, innovative materials engineering is important in solving the energy crisis problem. One such innovation in materials engineering is porous materials for energy storage. Porous electrode materials for lithium-ion batteries (LIBs) offer a high degree of electrolyte-electrode wettability, thus enhancing the electrochemical activity within the material. Among the porous materials, mesoporous materials draw special attention, owing to shorter diffusion lengths for Li+ and electronic movement. Nanostructured mesoporous materials also offer better packing density compared to their nanostructured counterparts such as nanopowders, ...
Focused Ion Beam (FIB) technology has become an indispensable enabling tool for micro nano fabrications. One important application is to use FIB for patterning conducting nanowires of metals down to a few tens of nanometre for applications such as interconnects, heaters and temperature nanosensors. A series of experiments on Au nanowires fabricated by FIB on SixNy membrane show that nanowires with width 50nm have structural instabilities. These are liquid like and first show-up as undulations in nanowire width with clearly defined wave lengths. For smaller widths (20nm) the instabilities grow and the wires eventually break-up into spherical balls. Further experiments show that the nanowires can be made stable to smaller widths by the use of a Cr underlayer to enhance surface wetting. The o...
A Si array neutron detector is proposed based on commercial CCD and CMOS sensor technology coupled with a thin film neutron conversion coating. System sensitivity is estimated for a baseline device containing a single array and various schemes to increase detection probability by simple area scaling and stacking are discussed. Some possible use scenarios are discussed involving static and moving sources. Likely neutron source fluxes for weapons grade and commercial grade nuclear material are estimated along with expected intensities of cosmic background neutrons which would establish a noise floor to detection limits.
Total-dose irradiation seriously damages MOS devices and their circuit performance. Threshold voltage shifts, transconductance degradation and increase in off-state leakage current are generally observed for irradiated devices. These instabilities are essentially due to positive and/or negative charge trapping in SiO_2 and interface trap generation at the SiO_2/Si interface. Radiation hardening of CMOS VLSIs is to eliminate these trapping effects, and for this purpose, special considerations for fabrication processes and layout design are necessary. In this paper, basic mechanisms for radiation-induced charge trapping and related effects on MOS devices are reviewed. Also discussed are radiation-hardening technologies from both fabrication-process and layout-design viewpoints. Using these technologies, 1 #mu#m radiation-hard CMOS gate arrays have been successfully developed. Experimental data taken for ...
Focused ion beam (FIB) milling is a powerful and versatile tool for the maskless fabrication of structures and devices at micro- and nanometer scales. The approach is based on the milling and deposition capabilities of a focused ion beam, where the latter is achieved by ion-beam-assisted decomposition of a metalorganic gas precursor of the specific material that has to be deposited. The combination of FIB and scanning electron microscopy in the same unit (so-called dual-beam unit) further expands the capabilities of the approach by the possibility of performing electron-beam-assisted deposition and inspection. Permalloy nanowires with electrical contacts patterned by FIB-Pt deposition were prepared in the dual-beam unit. Various types of notches to pin magnetic domain walls were additionally fabricated by means of FIB. The fabrication parameters for a structural modification of the Permalloy structures without too strongly affecting the ...
We study the possibility of utilizing the superfluid to Mott-insulator quantum phase transition in an array of quantum well exciton-polariton traps to generate indistinguishable single photons in a massive parallel fashion. By means of analytical and numerical methods, the device operations and system properties are examined using realistic experimental parameters. Such a deterministic, massive parallel generation may find new applications in photonic quantum information processing.
The use of dendrimers for preparing chemically sensitive interfaces for detecting volatile organic compounds (VOCs) using surface acoustic wave (SAW) device transducers is described. Specifically, the synthesis of the dendrimers and the means by which they are affixed to SAW devices is discussed, followed by a detailed spectroscopic analysis of the surface-confined dendrimers and a discussion of their interaction with different VOCs. Most of these preliminary experiments focus on dendrimer surface modification using benzoylchloride, which leads to phenyl terminal groups linked to the dendrimer via amide groups. The results of this study lead us to conclude that dendrimers: (1) provide general specificity towards classes of functional groups and are therefore suitable for array-based sensing schemes; (2) are intermediate in structure between monolayers and polymers and exhibit the desirable properties of both; (3) can be ...
It has been shown that two-dimensional arrays of rigid or fluidlike cylinders in a fluid or a gas define, in the limit of large wavelengths, a class of acoustic metamaterials whose effective parameters (sound velocity and density) can be tailored up to a certain limit. This work goes a step further by considering arrays of solid cylinders in which the elastic properties of cylinders are taken into account. We have also treated mixtures of two different elastic cylinders. It is shown that both effects broaden the range of acoustic parameters available for designing metamaterials. For example, it is predicted that metamaterials with perfect matching of impedance with air are now possible by using aerogel and rigid cylinders equally distributed in a square lattice. As a potential application of the proposed metamaterial, we present a gradient index lens for airborne sound (i.e. a sonic Wood lens) whose functionality is demonstrated by multiple ...
Permalloy (Ni{sub 80}Fe{sub 20})/Cu multilayered nanowires (NWs) were electrodeposited using a template directed method from sulfate baths via pulse potential technique. Microstructures and compositions of the nanowires were characterized using various microscopy and spectroscopy techniques. To synthesize compositionally uniform nanowires with high efficiency, new sulfate baths with a high content of Ni{sup 2+} were developed. The effects of deposition potential and concentration of metal ions were optimized to reduce composition inhomogeneity and incorporation of copper in the permalloy layers. Composition of the NiFe layers was found to be close to 20 at% Fe with a maximum of 5 at% Cu. TEM analysis indicated that individual nanowires exhibit distinct and coherent layering structure with rough and wavy interfaces. A synthesized single nanowire was also AC dielectrophoretically ...
Single-crystalline PbTe nanowires were synthesized using the chemical vapor transport method. They consisted of rock-salt structure PbTe nanocrystals uniformly grown in the [100] direction. We fabricated field-effect transistors using a single PbTe nanowire, providing evidence for its intrinsic n-type semiconductor characteristics. The values of the carrier mobility and concentration were estimated to be 0.83 cm"2 V"-"1 s"-"1 and 8.8 x 10"1"7 cm"-"3, respectively. The Seebeck coefficients (-72 ?V K"-"1) of individual nanowires were measured to show their n-type carrier-dominated thermoelectric transport properties.
The pressure dependence of the photoluminescence (PL) transition associated with the fundamental band gap of ZnO nanowires has been studied at pressures up to 15 GPa. ZnO nanowires are found to have a higher structural phase transition pressure around 12 GPa as compared to 9.0 GPa for bulk ZnO. The pressure-induced energy shift of the near band-edge luminescence emission yields a linear pressure coefficient of 29.6 meV/GPa with a small sublinear term of -0.43 meV/GPa{sup 2}. An effective hydrostatic deformation potential -3.97 eV for the direct band gap of the ZnO nanowires is derived from the result.
Europium (Eu) ions-doped titanate nanowires were synthesized via a sol-gel-hydrothermal chemistry and they were found to be roll multilayered trititanate-type nanowires intercalated with Eu3+ and alkali ions. The average diameter was about 20 nm for nanowires synthesized in NaOH solution and about 10 nm for nanowires synthesized in KOH solution. Under ultraviolet excitation the nanowires showed bright red emission corresponding to 5D0-7Fj of Eu3+ ions at room temperature, which was attributed to the non-radiative energy transfer from the surrounding Ti-O octahedral nanosheets to the central Eu3+ ions in interlayer. The luminescent properties of nanowires were influenced by the type of co-intercalated alkali ions, doping degree, hydrothermal and annealing temperatures. The intensity ratio of 5D0-7F2 to 5D0-7F1 of titanate nanowires ...
A numerical study of laminar flow and heat transfer in an array of stacked rectangular plates is presented. The array is placed in a uniform stream, and the plates are subjected to a constant surface heat flux. This flow configuration is relevant to a number of practical heat transfer devices with finned surfaces. The computations were performed using a finite volume solution of the steady, two-dimensional Navier-Stokes equations and energy equation. A numerical scheme that reduces numerical diffusion is used to discretize the equations. The dominant feature of the flow is the separation, and subsequent reattachment of, the boundary layer, which takes place at Reynolds numbers greater than about 75. The separation first occurs downstream of the leading edge of the plate; then as Re increases, the separation point moves upstream and remains fixed at the leading edge, and the reattachment length increases linearly with Re. ...
We will report on a new type of tunable semiconductor laser, which is based on the electronic selection of one Bragg grating among an array of such gratings in silica. The device that we have built operates at 120 Mb/s but extension to 1 Gb/s for Gigabit-Ethernet applications would be straightforward. In comparison with tunable semiconductor lasers using gratings in the III-V materials, silica gratings offer two significant advantages: 1-wavelength stability and predictability, 2-the ability to phusically overlap many gratings in a compact space in order to enable the selection of a large number of wavelengths for wavelength division multiplexed communications systems. The time required to chagne the wavelength in our laser has not been measured for lack of the necessary electronics but it is expected to be in the microsecond range on the basis of a straightforward calculation. The robust all solid-state nature of our ...
Off-axis electron holography is used to characterize a linear array of transistors, which was prepared for examination in cross-sectional geometry in the transmission electron microscope (TEM) using focused ion beam (FIB) milling from the substrate side of the semiconductor device. The measured electrostatic potential is compared with results obtained from TEM specimens prepared using the more conventional 'trench' FIB geometry. The use of carbon coating to remove specimen charging effects, which result in electrostatic fringing fields outside 'trench' specimens, is demonstrated. Such fringing fields are not observed after milling from the substrate side of the device. Analysis of the measured holographic phase images suggests that the electrically inactive layer on the surface of each FIB-milled specimen typically has a thickness of 100 nm.
This paper presents a study on the crystallization and growth mechanism of selenium nanowires induced by silver nanoparticles at ambient conditions with special reference to the effects of factors such as the shapes and size of silver nanoparticles, the induced reaction time, and the molar ratio of Ag{sup 0} to SeO{sub 3}{sup 2-} ions. The synthesis approach is conducted with no need of any stabilizers, and with no sonochemical process and/or templates. It is found that whether silver spherical particles or colloids can lead to the formation of nanowires with average diameter of 25 nm and lengths up to a few micrometers, and silver nanoplates lead to the formation of flat Se nanostructures. In particular, Au, Cu, Pt, and Pd particles cannot induce the growth of selenium nanowires in aqueous solution at room temperature. The results indicate that silver particles play a critical role in determining the growth of selenium ...
We used light confinement in optical microcavities to achieve a strong enhancement and a precise wavelength tunability of the electrical photoconductance of nanostructured porous silicon (PS). The devices consist of a periodic array of alternating PS layers, electrochemically etched to have high and low porosities - and therefore distinct dielectric functions. A central layer having a doubled thickness breaks up the symmetry of the one-dimensional photonic structure, producing a resonance in the photonic band gap that is clearly observed in the reflectance spectrum. The devices were transferred to a glass coated with a transparent SnO{sub 2} electrode, while an Al contact was evaporated on its back side. The electrical conductance was measured as a function of the photon energy. A strong enhancement of the conductance is obtained in a narrow (17nm FWHM) band peaking at the resonance. We present experimental results of the ...
We report studies of bimetallic nanoparticles with 15%-16% atomic crystal parameters size mismatch. The degree of alloying was probed in a 2-nm Pt core (smallest attainable core size) of Pt-Ag nanoparticles (completely immiscible in bulk) and 20-nm-diameter Pd-Ag nanowires (completely miscible in bulk). Particles were synthesized radiolytically, and depending on the initial parameters, they assume spherical or cylindrical (nanowire) morphologies. In all cases, the metals are seen to follow their bulk alloying characteristics. Pt and Ag segregate in both spherical and wire forms, which indicates that strain due to crystallographic mismatch overcomes the excess surface free energy in the small particles. The Pd-Ag nanowires alloy similar to previously reported spherical Pd-Ag particles of similar diameter and composition.
We report the observation of quantum interference in superfluid 4He. The interferometer, an analog of a dc-superconducting quantum interference device (SQUID), employs a recently reported phenomenon wherein superfluid 4He exhibits Josephson frequency oscillations in an array of submicron apertures. An interference pattern is generated by reorienting the loop of the superfluid 'SQUID' with respect to the Earth's rotation vector, thereby varying the rotation flux in the loop. The experiment is performed at 2 K, a temperature 2000 times higher than previously achieved with superfluid 3He. We find that the interference exists not only when the aperture array current-phase relation is a sinusoidal function characteristic of the Josephson effect, but also at lower temperatures where it is linear and oscillations occur by phase slips. The modest requirements for the interferometer (2 K cryogenics and fabrication of apertures at ...
A butterfly valve is a type of flow control device, typically used to regulate a fluid flowing. Currently, FEA is often used to predict the safety in the design of valve disc. Also, the study about the affection of butterfly valve's disc to the valve flow characteristics by using CFD has been done by many researchers. Along with the development of computer technique, design and analysis of computer experiments has becoming more and more important in engineering design and optimization. Hereinto Kriging model is one popular analysis approach for the purpose of creating a cheap ``meta-model'' as a surrogate to a computationally expensive simulation model. In this paper, the numerical analysis considered the strength, pressure loss coefficient and weight of valve disc simultaneously is investigated to improve the shape of a traditional butterfly valve disc. Firstly, an initial model of butterfly valve is made to evaluate the performance of the valve disc by using CFD ...
We describe a new concept for a MEMS-based active spatial filter for astronomical spectroscopy. The goal of this device is to allow the use of a diffraction-limited spectrometer on a seeing limited observation at improved throughput over a comparable seeing-limited spectrometer, thus reducing the size and cost of the spectrometer by a factor proportional to r0/D (For the case of a 10 meter telescope this size reduction will be approximately a factor of 25 to 50). We use a fiber-based integral field unit (IFU) that incorporates an active MEMS mirror array to feed an astronomical spectrograph. A fast camera is used in parallel to sense speckle images at a spatial resolution of lambda/D and at a temporal frequency greater than that of atmospheric fluctuations. The MEMS mirror-array is used as an active shutter to feed speckle images above a preset intensity threshold to the spectrometer, thereby increasing the signal-to-noise ...
One method of increasing juvenile fish escapement from net cod-ends is to encourage fish to approach the netting by placing an active stimulating device (ASD) in the cod-end. Two types of ASD were tested inside model cod-ends to generate variable visual stimuli. One was a free-end flag-like net panel and the other consisted of an array of free-ended ropes. Escape responses of juvenile red seabream were observed in a circulating water channel using a cod-end fitted with the ASD, and they were compared with responses to conventional polyethylene multi-ply, high-contrast cod-ends with and without ASD made from either 28- or 43-mm mesh under three light conditions. With the ASD attached, the retention rate was significantly lower, 20%, than for conventional cod-ends except in dim light with 28...
Crystalline ?-Al2O3 nanowires with diameter, 20?40?nm, length above 600?nm and aspect ratio above 30 have been successfully synthesized by thermal decomposition of boehmite (?-AlOOH) precursors obtained via hydrothermal route by using AlCl3, NaOH and NH3 as starting materials. Thermogravimetric analysis (TG), differential thermal analysis (DTA), X-ray diffraction (XRD), transmission electron microscope (TEM), selected area electron diffraction (SAED) and high resolution transmission electron microscope (HRTEM) were used to characterize the features of the as-made ?-Al2O3 nanowires and their ?-AlOOH precursors. The pH value of the solution and the mixed precipitant play important roles in the formation of ?-AlOOH nanowires. After calcination at 500?C for 2?h, the orthorhombic ?-AlOOH transf...
Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...
In a recent paper, Lowry (1981) described an architecture for a computer vision rectangular processor array that is suitable for VLSI implementation. In this paper the authors review that architecture, discuss extensions to it and present results of an array simulator applied to vision algorithms. They also present an algorithm for re-routing an array with bad processors into a working subset of the array, making it feasible to implement a large array on one wafer-sized chip. 7 references.
The research supported by this Department of Energy contract has primarily been devoted to the study of the electronic properties of surfaces with sub-micron size. In previous years, we have studied the photoexcitation of electrons from field emission tips by a focussed Argon-ion laser beam tuned to operate at specific photon energy. The photoexcited electrons escape into the vacuum by tunneling through a surface potential barrier which is distorted by the application of a strong electric field. The interest in these experiments lies in a better understanding of the photoexcitation process at low photon energies. The techniques that have been developed directly measure the excited state energy distribution of electrons emitted through the surface potential barrier. The basic information gained from this research is relevant to opto-electronic devices which rely on photoexcitation of electrons in the presence of strong interfacial electric fields for their ...
The visible semiconductor laser includes an InAlGaP active region surrounded by one or more AlGaAs layers on each side, with carbon as the sole p-type dopant. Embodiments of the invention are provided as vertical-cavity surface-emitting lasers (VCSELs) and as edge-emitting lasers (EELs). One or more transition layers comprised of a substantially indium-free semiconductor alloy such as AlAsP, AlGaAsP, or the like may be provided between the InAlGaP active region and the AlGaAS DBR mirrors or confinement layers to improve carrier injection and device efficiency by reducing any band offsets. Visible VCSEL devices fabricated according to the invention with a one-wavelength-thick (1{lambda}) optical cavity operate continuous-wave (cw) with lasing output powers up to 8 mW, and a peak power conversion efficiency of up to 11%. 5 figs.
Focused-ion beam (FIB) milling provides rapid fabrication of individual cylindrical submicrometer channels with reproducible dimensions (#+-#5% diameters) through 8-#mu#m thick poly(methylmethacrylate) (PMMA) films. PMMA films are spincast on sacrificial Si carriers and sputter-coated with Au before the 30-kV gallium FIB milling process. By adding a trace amount of poly(ethyleneoxide) and poly(dimethylsiloxane) to the PMMA solution before casting, the films can be released for subsequent mounting in microfluidic devices to create hybrid microfluidic-nanofluidic multilevel architectures. In situ FIB sectioning demonstrates the smooth cylindrical surface within the pore. Placing a milled film in contact with an aqueous fluorescein solution fills the channel by capillary action, as verified by confocal fluorescence microscopy. Confocal fluorescence of dyed films reveals that the pores span the thickness of the PMMA film. Small arrays of channels ...
A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of ...
The research supported by this Department of Energy contract has primarily been devoted to the study of the electronic properties of surfaces with sub-micron size. In previous years, we have studied the photoexcitation of electrons from field emission tips by a focussed Argon-ion laser beam tuned to operate at specific photon energy. The photoexcited electrons escape into the vacuum by tunneling through a surface potential barrier which is distorted by the application of a strong electric field. The interest in these experiments lies in a better understanding of the photoexcitation process at low photon energies. The techniques that have been developed directly measure the excited state energy distribution of electrons emitted through the surface potential barrier. The basic information gained from this research is relevant to opto-electronic devices which rely on photoexcitation of electrons in the presence of strong interfacial electric fields for their ...
Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering caused by grain structures and to determine the consistency of ultrasonic responses ...
Thin-film solar cells on flexible, lightweight, space-qualified substrates provide an attractive approach to fabricating solar arrays with high mass-specific power. A polycrystalline chalcopyrite absorber layer is among the new generation of photovoltaic device technologies for thin film solar cells. At NASA Glenn Research Center we have focused on the development of new single-source precursors (SSPs) for deposition of semiconducting chalcopyrite materials onto lightweight, flexible substrates. We describe the syntheses and thermal modulation of SSPs via molecular engineering. Copper indium disulfide and related thin-film materials were deposited via aerosol-assisted chemical vapor deposition using SSPs. Processing and post-processing parameters were varied in order to modify morphology, stoichiometry, crystallography, electrical properties, and optical properties to optimize device quality. Growth at atmospheric pressure ...
This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode near the GaAs bandedge is over 90%. The ...
Outline: Discuss far-side weld problem and phased array techniques applied. Describe laboratory work on flawed piping specimens using L- and S-wave arrays and provide synopsis of results. Discuss conclusions ofr capability of phased array as applied to austenitic welds. Research Approach: Evaluate phased arrays on unifornly-welded piping specimens. Apply best methods to non-uniform welds. Correlate acoustic responses as function of weld microstructures.
Phased array provides many advantages over conventional ultrasonic testing method, but phased array has also limitations. This paper describes typical results of the experimental sound field analysis generated from the array probe. A photo-elastic ultrasonic visualization technique was applied in this study. The sound fields of shear wave generated from the array probe was equivalent to that from the fixed angle probe. (author)
Focused Ion Beams are an important approach for nanostructure fabrication in the semiconductor industry and material sciences. Applications in sputtering and ion induced deposition of materials are investigated. The IMSA FIB system equipped with the high resolution Orsay Physics CANION M31plus ion column with current densities up to 10 A/cm"2 including a gas injection system is applied. In this work the ion beam induced chemical vapour deposition of tungsten, wherefore tungsten hexacarbonyl as precursor gas is used for a first investigation. Conductive tungsten-nanowires with smallest cross-section upon a substrate of Si and SiO_2 are produced. The ion beam parameters of this focused ion beam system are optimized for the metal deposition. A short insight in the theory of layer nucleation and growth induced by the ion beam during the metal deposition is given. The layer quality is determined by Auger electron analysis which shows the components in atomic percent ...
A compact heat exchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heat exchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...
MILSTAR's Flexible Substrate Solar Array (FSSA) is an evolutionary development of the lightweight, flexible substrate design pioneered at Lockheed during the seventies. Many of the features of the design are related to the Solar Array Flight Experiment (SAFE), flown on STS-41D in 1984. FSSA development has created a substantial technology base for future flexible substrate solar arrays such as the array for the Space Station Freedom. Lessons learned during the development of the FSSA can and should be applied to the Freedom array and other future flexible substrate designs.
By means of ab-initio electronic structure calculation and one-dimensional Boltzmann transport equation solution, we investigate the size dependent thermoelectric (TE) properties of n-type ZnO nanowires (NWs) and surface passivation effects. As demonstrated by our calculations, largest figure of merit ZT achievable in thin NWs is larger than that in wide NWs, whereas being restrained by higher demand of n-type doping. Moreover, bare NWs are superior in TE application comparing with the passivated. To compete with conventional TE materials, lattice thermal conductivity of ZnO NWs should be at least 2 orders of magnitude lower than bulk value.
In this paper we demonstrate the electrodeposition of nickel, a common ferromagnetic material, in various magnetically desirable shapes including nanowires, nanoparticles and highly faceted shells. In order to obtain three dimensional mesostructures, the electrochemical deposition of nickel was performed on highly oriented pyrolytic graphite (HOPG) under different electrolyte composition and deposition potential conditions. Under potentiostatic deposition at one distinct potential negative with respect to the reversible potential of nickel, three stages of nucleation and growth take place leading to a complex morphology of deposits. However, dual-pulse potential deposition and electrodeposition in low pH solutions causing hydrogen evolution, lead to nickel deposits in the form of nanowires...
One-dimensional core-shell polymer nanowires offer many advantages and great potential for many different applications. In this paper we introduce a highly versatile two-step template wetting process to fabricate two-component core-shell polymer nanowires with controllable shell thickness. PLLA and PMMA were chosen as model polymers to demonstrate the feasibility of this process. Solution wetting with different concentrations of polymer solutions was used to fabricate the shell layer and melt wetting was used to fill the shell with the core polymer. The shell thickness was analyzed as a function of the polymer solution concentration and viscosity, and the core-shell morphology was observed with TEM. This paper demonstrates the feasibility of fabricating polymer core-shell nanostructures using our two-step template wetting process and opens the arena for optimization and future experiments with polymers that are desirable for specific ...
An electrochemical biosensor for determination of hydrogen peroxide (H2O2) was fabricated, based on the electrostatic immobilization of horseradish peroxidase (HRP) with one-dimensional gold nanowires (Au NWs) and TiO2 nanoparticles (nano-TiO2) on a gold electrode. The nano-TiO2 can give a biocompatible microenvironment and compact film, and the Au NWs can provide fast electron transferring rate and greatly add the amount of HRP molecules immobilized on the electrode surface. Au NWs were characterized by ultraviolet?visible spectra and transmission electron microscope. The electrode modification process was probed by cyclic voltammetry and electrochemical impedance spectroscopy. Chronoamperometry was used to study the electrochemical performance of the resulting biosensor. Under optimal co...
This paper presents a new approach to improve the in silico modeling of ultrasound transducer arrays. While current simulation tools accurately predict the theoretical element...Full Text Available
PLZT-7/65/35 is a ferroelectric ceramic with strong electrooptic properties and memory; it is switched through transparent electrodes when mechanically strained. Matrix addressed x-y page composers for interfacing electrical and coherent optical systems are being fabricated with PLZT. Switching voltages are 50-300 V. Optical efficiencies greater than 40% have been achieved. Strains near 2.4 x 10(-3) mm/mm permit half-wave retardation switching in 100-micro-thick plates with 80-V read-in and 190-V erase levels (60 Hz hysteresis data). A 128 x 128 element array can operate at 10(7) bits/sec with 10-microsec switching in a row at a time mode. Half-select disturbances affect contrasts. Applications in displays are also feasible. PMID:20111514
Self-assembled quantum dots (QDs) are envisioned as building blocks for realization of novel nanoelectronic devices, for which the site-selective growth is highly desirable. This thesis presents a successful route toward selective positioning of self-assembled InAs QDs on patterned GaAs surface by combination of in situ focused ion beam (FIB) implantation and molecular beam epitaxy (MBE) technology. First, a buffer layer of GaAs was grown by MBE before a square array of holes with a pitch of 1-2 #mu#m was fabricated by FIB implantation of Ga and In, ions respectively. Later, an in-situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by FIB. The influence of ion dose, annealing parameters and InAs amount was investigated in this work. With optimized parameters, more than 50 % single dot occupancy per hole is achieved. Furthermore, the photoluminescence spectra from ...
KM3NeT is a future deep-sea research infrastructure hosting a neutrino telescope with a volume of at least one cubic kilometer to be constructed in the Mediterranean Sea. The experiment aims to detect high-energy cosmic neutrinos using a 3D array of optical modules to collect the Cherenkov light induced by charged particles in the water. Upward going muons and showers produced in neutrino interactions with the surrounding matter will allow the search and study of possible sources of extra-terrestrial neutrinos. The design of optical modules makes an important impact on the performance and cost of the KM3NeT project. Several different optical module configurations are under consideration; based on glass pressure spheres containing: a large (10 in.) hemispherical photomultiplier tube (with a multi-anode version as an option); 25-31 3 in. photomultiplier tubes, or a crystal scintillator-based hybrid device (X-HPD). The features and advantages of ...
We demonstrate detection of a single core-shell magnetite-silica nanoparticle (outer diameter #approx#120 nm, moment #approx#10"4#mu#_B) using an Nb dc superconducting quantum interference device (SQUID) with the loop size of 350 nm operational at T < 10 K. The system noise was minimized down to 0.2 #mu##PHI#_0 Hz"-"1"/"2 using a cryogenic SQUID series array pre-amplifier. Initial measurements of an individual magnetic nanoparticle were performed and a clear change of the noise spectra of the nano-SQUID was detected at low frequencies in the presence of the nanoparticle. Similar behaviour was confirmed with an FePt nanoparticle with a larger magnetic moment (diameter #approx#150 nm, moment #approx#10"6#mu#_B). Thus, we demonstrate a magnetic sensor based on a dc nano-SQUID and enabling detection of small moments (potentially down to a few electron spins). Such a sensor is of considerable significance for nanomagnetic metrology and quantum ...
A knowledge of surface film growth kinetics can be quite useful in the production of materials for uses ranging from protective coatings to microelectronic devices. A technique for determining the kinetics of film growth is presented which should prove to be a valuable alternative to the array of spectroscopies (AES, RBS, etc.) currently favored for these measurements. Some of the virtues of this X-ray diffraction approach are its non-destructive nature, thickness resolution better than 50 {angstrom} and conventional equipment requirements. Results obtained for the growth of Pd{sub 2}Si films during thermal annealing of Pd coatings on Si, indicate parabolic growth over a temperature range of 160-222 C. The rate constant was found to be k{prime} = 7 {times} 10{sup {minus}4} exp ({minus}1.06 eV/kT) cm{sup 2}/sec, where (film thickness){sup 2} = k{prime} x time. This activation energy is in agreement with results obtained by other techniques. A ...
An Ethernet based embedded system has been developed to upgrade the Beam Viewer and Beam Position Monitor (BPM) systems within the free-electron laser (FEL) project at Jefferson Lab. The embedded microcontroller was mounted on the front-end I/O cards with software packages such as Experimental Physics and Industrial Control System (EPICS) and Real Time Executive for Multiprocessor System (RTEMS) running as an Input/Output Controller (IOC). By cross compiling with the EPICS, the RTEMS kernel, IOC device supports, and databases all of these can be downloaded into the microcontroller. The first version of the BPM electronics based on the embedded controller was built and is currently running in our FEL system. The new version of BPM that will use a Single Board IOC (SBIOC), which integrates with an Field Programming Gate Array (FPGA) and a ColdFire embedded microcontroller, is presently under development. The new system has the features of a low ...
The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.
The Engineering and Technology Validation Team at the National Renewable Energy Laboratory (NREL) conducts in-situ technical evaluations of polycrystalline thin-film photovoltaic (PV) modules and arrays. This paper focuses on the technical evaluation of Solar Cells, Inc., (SCI) cadmium telluride (CdTe) module and array performance by attempting to correlate individual module and array performance. This is done by examining the performance and stability of the modules and array over a period of more than one year. Temperature coefficients for module and array parameters (P{sub max}, V{sub oc}, V{sub max}, I{sub sc}, I{sub max}) are also calculated.
We analyse numerically the acoustic stop band properties of an array of orthotropic coated cylinders whose elastic parameters are deduced from a geometric transform [H. Chen, C.T. Chan, Acoustic cloaking in three dimensions using acoustic metamaterials, Appl. Phys. Lett. 91 (2007) 183518]. We find that whereas a single coated inclusion is acoustically neutral at any frequency, an array of them might display some stop bands. More precisely, an array of freely vibrating coated voids is always neutral, whereas an array of clamped coated inclusions might display a zero frequency stop band. Interestingly, an array of radially symmetric coated inclusions behaves as local Helmholtz resonators, for which the eigenfield within each cloak is obtained in closed form, leading to a frequency estimate a...
Nanowires of copolymers film based on aniline and 1-amino-2-naphthol-4-sulphonic acid were electrochemically synthesized on the iron electrode by cyclic voltammetry using oxalic acid as a supporting electrolyte. Protective properties of copolymer film on the iron surface in 1.0 M HCl solution was investigated by chronoamperometry, potentiodynamic polarization technique and electrochemical impedance spectroscopy (EIS). The results showed that the copolymer film showed the significant shifting in the corrosion potential and greater charge transfer resistance. Moreover, the copolymer showed the larger degree of surface coverage onto the iron surface, reflecting the higher protection for corrosion of the iron in acidic medium. In addition, the film constitutes a physical as well as a chemical barrier layer due to the presence of -OH and -NH groups in ANSA unit, which provides passivity protection in polymer coatings. The mechanism of corrosion protection of iron by ...
chipD is a web server that facilitates design of DNA oligonucleotide probes for high-density tiling arrays, which can be used in a number of genomic applications such as ChIP-chip or gene-expression...Full Text Available
Oct 20, 1997 ... The following requirements apply to the solar array: ..... housings will be coated with material meeting the program's outgassing requirements. ... The solar array temperature testing requirements will be determined by analysis. .... The ADS also generates attitude products for the project and science team. ...
Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...
Destress blasting is commonly used as a stress control technique at the Galena Mine, Wallace, Idaho, where the U.S. Bureau of Mines maintains a cooperative research program with the mine operators (ASARCO). A digital seismic array and an array of borehole...
French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
We present an algorithm to identify individual neural spikes observed on high-density multi-electrode arrays (MEAs). Our method can distinguish large numbers of distinct neural units, even when spikes...Full Text Available
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
In the present work, we describe application of binary pseudo-random gratings (BPRG) and arrays (BPRA) as effective 1D and 2D test surfaces suitable for calibration of different surface profilometers, including a number of interferometric microscopes and scatterometers.
The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.
We have designed a new nucleobase, benzodeazaadenine (BDA) that has a stronger charge transport ability than guanine and is not destroyed during charge transport process. By incorporating this new nucleobase into DNA, we demonstrated a protocol for real DNA nano-wire that is far superior to natural DNA. We also demonstrated that the selectivity for the interaction of Mn(II) ion with guanine N7 in G runs is a HOMO-controlled process, and as a consequence, the selectivity for G-metal ion interactions obtained by 15N-NMR studies would directly reflect the HOMO distribution of G-containing sequences in B-DNA. PMID:12903077
... as time delay shifters for large-area phased arrays in military (MILSTAR) as well as commercial (Sky phone and other satellite communication) systems, ...
This paper reports progress in the fabrication and characterization of an array of 1nm-scale colloidal particles (i.e., quantum-dot array) that can be operated to execute nontrivial and innovative computations, possibly including quantum logic. We discuss the actual fabrication of 2-nm metal clusters as an example of possible quantum dot implementation. Innovative and unconventional paradigms underlie the different stages of this work. For example, regular array geometry is achieved by directing appropriately derivatized metal clusters to preselected locations along a stretched strand of an engineered DNA sequence.
... the application of an acousto- optical tunable filter ... Couplers for Large Switch-Array Applications ... Symmetric Integrated Optic X Junction," Electronics ...
There is considerable interest in the use of silicon devices as qubits for quantum computing. The existence of nuclear spin in a silicon isotope and the complex band structure of silicon are unfavourable for this application of silicon devices. (viewpoint)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.
Whooper swans habitat in the coastal regions of Denmark can be affected by wind turbine arrays on the coast. The planned array consists of 55 wind turbines very close to the swan breeding area. A possibility of moving the swans away from the windmill area would be to spread the preferred swan feeds (rape, potatoes) outside their present breeding ground. (EG) 14 refs.
This paper addresses one source of degradation in OPV devices: the metal/organic interface. The basic approach was to study the completed device stability vs. the stability of the organic film itself as shown in subsequent devices fabricated from the films.
The application of the phased array technique was limited to heavy and thick wall components as present in the nuclear industry. With the improvement of the equipment and probes other application areas are now open for the phased array technique, e.g. the inspection of the turbine blade root, weld inspection in a wall thickness range between 12 and 40 mm, inspection of aircraft components, inspection of spot welds or inspection of concretes. The aim of the use of phased array techniques has not been changed related to the first applications, i.e. the adaptation of the sound beam to the geometry by steering the angel of incidence or the skewing angle as well as the focussing of sound fields. Due to the fact, that the new applications of the phased array techniques in some cases don't leave the laboratories for the time being, the examples of this contribution will focus applications with ...
Experiments are reported in which a methane plasma is created, and the methyl ions and hydrogen ions are accelerated within a microchannel array so that they interact with neutral methane molecules on the inside surfaces of the microchannels. No catalysts are used, and the device operates at room temperature. Impact energies of the ions are in the range of 10 eV to greater than 100 eV, and the energy delivered in the interaction at the surfaces causes the production of larger hydrocarbon molecules, such as C{sub 2}H{sub 2}, C{sub 2}H{sub 4}, and C{sub 2}H{sub 6}, along with C{sub 3}, C{sub 4}, C{sub 5}m C{sub 6}, C{sub 7}m and C{sub 8} molecules. There is a decreasing percentage of larger molecules produced, in comparison with the C{sub 2} and C{sub 3} types. Conversion effectiveness is greater at higher pressure, due to the increased ionic activity. The yield of the higher hydrocarbons depends upon the external voltage used, and voltage can be ...
High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 deg. C voxel-wise SDT) ...
... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...
To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader 2:0.818) showed ...
The synchronous orbit performance of Hughes Aircraft Company solar arrays is presented and compared with the results of ground based predictions for orbital durations of almost 11 years. Performances of the Intelsat IV*, IVA*, and Telesat (Anik) solar arrays are detailed. This paper is an update of the in-orbit performances previously reported in 1976 (1). The in-space performance data indicate solar array power degradation of 16.7 percent for Intelsat IV F-2 after 130 months in orbit, and 13.0 percent for Telesat F-1 after 85 months in orbit. The predicted output of each of these solar arrays is within 2 percent of the actual in-orbit performance of these systems. The Intelsat IV F-2 experienced the 4 August 1972 solar flare. The ability to accurately predict the performance of solar arrays within telemetry accuracy is demonstrated. This ability combines the electrical measurements ...
Nuclear steam generator tubes have become flawed in ways that challenge conventional eddy current probes. In response to the shortcomings of conventional probes, array probes have been developed to improve measurement capabilities. However, the commercially available array probes have exhibited several weaknesses that offset the advantages and limit the applications in steam generator inspections. A primary weakness is the relatively high rate of probe failure coupled with the high unit cost for each probe. This can be costly for a utility in the time lost for probe replacement and increased radiation exposure in addition to the probe costs. Other weaknesses which make array probes undesirable for routine use are: poor mechanical and electrical characteristics; difficulty in operation and calibration; and incomplete coverage of the tube circumference. Several prototype array probes have been built to ...
A monolithic micromachined waveguide device or devices with low-loss, high-power handling, and near-optical frequency ranges is set forth. The waveguide and integrated devices are capable of transmitting near-optical frequencies due to optical-quality sidewall roughness. The device or devices are fabricated in parallel, may be mass produced using a LIGA manufacturing process, and may include a passive component such as a diplexer and/or an active capping layer capable of particularized signal processing of the waveforms propagated by the waveguide.
A preliminary design effort directed toward a low concentration ratio photovoltaic array system capable of delivering multihundred kilowatts (300 kW to 1000 kW range) in low earth orbit is described. The array system consists of two or more array modules each capable of delivering between 113 kW to 175 kW using silicon solar cells or gallium arsenide solar cells, respectively. The array module deployed area is 1320 square meters and consists of 4356 pyramidal concentrator elements. The module, when stowed in the Space Shuttle's payload bay, has a stowage volume of a cube with 3.24 meters on a side. The concentrator elements are sized for a geometric concentration ratio (GCR) of six with an aperture area of .25 sq. m. The structural analysis and design trades leading to the baseline design are discussed. It describes the configuration, as well as optical, thermal and electrical performance ...
A metamaterial that is composed of solid viscoelastic elements with controllable properties is proposed in this Letter. This enables an adaptable and general acoustic metamaterial to be practically realised. An array of masses with a single elastic connection to a supporting viscoelastic structure, such as one that is dynamically equivalent to an array of Helmholtz resonators, only provides a system with negative effective mass. A local active control scheme applied to each of these masses can emulate additional elastic connections to the supporting structure. An array of masses with a suitable local control scheme can provide both the negative effective stiffness and mass required for negative refraction. The tuneable feedback control parameters determine the characteristics of the region...
Problems of classification and regression estimation in which objects are represented by multidimensional arrays of features are considered. Many practical statements can be reduced to such problems, for example, the popular approach to the description of images as a set of patches and a set of descriptors in each patch or the description of an object in the form of a set of distances from it to certain support objects selected based on a set of features. For solving problems concerning the objects thus described, a generalization of the relevance vector model is proposed. In this generalization, specific regularization coefficients are defined for each dimension of the multidimensional array of the object description; the resultant regularization coefficient for a given element in the mul...
The problems in computer vision range from edge detection and segmentation at the lowest level to the problem of cognition at the highest level. This correspondence describes the organization and operation of a semantic network array processor (SNAP) as applicable to high level computer vision problems. The architecture consists of an array of identical cells each containing a content addressable memory, microprogram control, and a communication unit. The applications discussed in this paper are the two general techniques, discrete relaxation and dynamic programming. While the discrete relaxation is discussed with reference to scene labeling and edge interpretation, the dynamic programming is tuned for stereo.
Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.
Oxide charge on the sidewalls of SiO{sub 2} embedded silicon wires with 20x20 nm{sup 2} cross section is shown to influence the Schottky barrier height for Pd{sub 2}Si/Si junctions positioned on the end surfaces of the wires. Compared with results on planar silicon surfaces, the electron barrier height is 0.3 eV lower for wires investigated as fabricated. By increasing the oxide charge through irradiation by ultraviolet light, the electron barrier decreases by an additional 0.15 eV and the hole barrier correspondingly increases by about the same amount. The phenomenon is explained by assuming an oxide charge density in the range of 10{sup 12} cm{sup -2}.
Synthesis, morphology, structural and optical characteristics of SiC NWs and SiC/C nanocomposites with an inverse opal lattice have been investigated. The samples were prepared by carbothermal reduction of silica (SiC NWs) and by thermo-chemical treatment of opal matrices (SiC/C) filled with carbon compounds which was followed by silicon dioxide dissolution. It was shown that the nucleation of SiC NWs occurs at the surface of carbon fibers felt. It was observed three preferred growth direction of the NWs: [111], [110] and [112]. HRTEM studies revealed the mechanism of the wires growth direction change. SiC/C- HRTEM revealed in the structure of the composites, except for silicon carbide, graphite and amorphous carbon, spherical carbon particles containing concentric graphite shells (onion-like particles).
Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.
Telomeres protect the chromosome ends from unscheduled DNA repair and degradation. Telomeres are heterochromatic domains composed of repetitive DNA (TTAGGG repeats) bound to an array of specialized...Full Text Available
Previous experimental data and theoretical analysis have demonstrated that ... products of a technological process) but also other contaminants. ..... Thorough outgassing of solar array surfaces may result in significant decrease of arc ...
Legionella causes severe pneumonia in humans. The pathogen produces an array of effectors, which interfere with host cell functions. Among them are the glucosyltransferases Lgt1, Lgt2...Full Text Available
shading trellis. This array powers all of the electric appliances, including an oven, cooktop, dishwasher, clothes washer and dryer, home entertainment systems (television and...
... A detailed analysis of QCM errors is ... Surface Effects of Satellite Outgassing Products." AIAA Journal ... 9. Rauschenbach, H. S. Solar Cell Array Design ...
Chemoreceptors are crucial components in the bacterial sensory systems that mediate chemotaxis. Chemotactic responses exhibit exquisite sensitivity, extensive dynamic range and precise adaptation....Full Text Available
The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure ...
Throughout the last decades, plasma technology has been established in a series of surface treatment applications, e.g. for semiconductor processing or optical coatings. The majority of plasma assisted technologies is based on low pressure processes. In recent years, however, non-thermal atmospheric pressure discharges have attracted considerable interest because of their simplified technical devices for industrial applications as compared to low pressure processes which require vacuum equipment. Hence, batch processing can be avoided, thus facilitating the implementation of plasma process steps into production lines. Investment costs are cut down significantly. The use of atmospheric pressure plasmas for technical applications dates back to the ozone production with dielectric barrier discharges (DBD) by Siemens in 1857. Lately, the application of atmospheric pressure plasmas for surface treatment has been reported, e.g. for the treatment of foils to improve ...
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
The device is designed for automatic testing of the degree of discharge of tractive storage batteries (AB) for electric loaders, electric cars and electric ore locomotives. The basic electrical schematic of the device is cited.
A device made of amorphous silicon which exhibits inductive properties at certain voltage biases and in certain frequency ranges in described. Devices of the type described can be made in integrated circuit form.
Nanometre-sized materials, like nanowires, nanoparticles or nanobelts, are gaining huge interest as building blocks of modern electronic nanodevices. Their fabrication feasibility has been demonstrated in the last years, and different routes are already well established in order to synthesize these materials. However, the assessment of their electrical properties is still a challenging issue, due to the difficulty to perform a precise nanolithography process allowing the access to such small structures. The fabrication of metallic contacts with precision in the nanometre range is necessary, as well as achieving a flexible system that allows to contact individual structures. Such a system could be a dual-beam Focused Ion Beam instrument, which combines Scanning Electron Microscopy (SEM) and Focused Ion Beam (FIB) in one machine, able to assist deposition of materials with nanometre precision. In this work, the methodology of fabrication of metallic nanocontacts to ...
Nanometre-sized materials, like nanowires, nanoparticles or nanobelts, are gaining huge interest as building blocks of modern electronic nanodevices. Their fabrication feasibility has been demonstrated in the last years, and different routes are already well established in order to synthesize these materials. However, the assessment of their electrical properties is still a challenging issue, due to the difficulty to perform a precise nanolithography process allowing the access to such small structures. The fabrication of metallic contacts with precision in the nanometre range is necessary, as well as achieving a flexible system that allows to contact individual structures. Such a system could be a dual-beam Focused Ion Beam instrument, which combines Scanning Electron Microscopy (SEM) and Focused Ion Beam (FIB) in one machine, able to assist deposition of materials with nanometre precision. In this work, the methodology of fabrication of metallic nanocontacts to ...
The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)
A CMOS programmable picture processor with its own photodiode array is presented. The circuit is novel in that it includes an instruction set that permits most low-level picture processing operations. The chip is a parallel machine with a processing unit for each picture element. Images are binarized and are processed line by line. An experimental chip has been designed and is under fabrication. 2 references.
The basic objective of this project was to consider a large class of matrix computations with particular emphasis on algorithms that can be implemented on arrays of processors. In particular, methods useful for sparse matrix computations were investigated. These computations arise in a variety of applications such as the solution of partial differential equations by multigrid methods and in the fitting of geodetic data. Some of the methods developed have already found their use on some of the newly developed architectures.
An experimental study was undertaken to determine for the turbulent regime the heat transfer and fluid flow characteristics of a heat exchange array of unperforated, and perforated brass plates with 33% of the plate area open. In both cases, the plates were aligned parallel to the flow direction. For the flow conditions examined, the results showed enhancement of heat transfer and friction factor for the perforated array.
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full ...
A preliminary design effort directed toward a low concentration ratio photovoltaic array system based on 1984 technology and capable of delivering multi-hundred kilowatts (300 kW to 100 kW range) in low Earth orbit is described. The array system consists of two or more array modules each capable of delivering between 113 kW to 175 kW using silicon solar cells or gallium arsenide solar cells, respectively. The array module deployed area is 1320 square meters and consists of 4356 pyramidal concentrator elements. The module, when stowed in the Space Shuttle's payload bay, has a stowage volume of a cube with 3.24 meters on a side. The concentrator elements are sized for a geometric concentration ratio (GCR) of six with an aperture area of 0.5 meters x 0.5 meters. Drawings for the preliminary design configuration and for the test hardware that was fabricated for design evaluation and test are ...
The goal of this LDRD was to demonstrate the use of robotic vehicles for deploying and autonomously reconfiguring seismic and acoustic sensor arrays with high (centimeter) accuracy to obtain enhancement of our capability to locate and characterize remote targets. The capability to accurately place sensors and then retrieve and reconfigure them allows sensors to be placed in phased arrays in an initial monitoring configuration and then to be reconfigured in an array tuned to the specific frequencies and directions of the selected target. This report reviews the findings and accomplishments achieved during this three-year project. This project successfully demonstrated autonomous deployment and retrieval of a payload package with an accuracy of a few centimeters using differential global positioning system (GPS) signals. It developed an autonomous, multisensor, temporally aligned, radio-frequency communication and signal ...
Single-event burnout (SEB) sensitivity was tested for power MOSFET devices, JTMCS081 and JTMCS062, which were made in Institute of Microelectronics, Chinese Academy of Sciences, using californium-252 simulation source. SEB voltage threshold was found for devices under test (DUT). It is helpful for engineers to choose devices used in satellites. (authors)
An integrated mirrorless bistable optical device based on the Mach-Zehnder interferometric optical switch has been proposed and demonstrated experimentally using a Ti:LiNbO3 waveguide. The resulting device is capable of combining more than two of them to realize multifunctional optical devices such as optical multivibrators.
We discuss the initial development of a concentrator device based on the GaInP/GaAs monolithic tandem cell structure. The very high one-sun efficiency of this device, coupled with its characteristic low operating current, make this a promising candidate for use under high concentration. Test results for a prototype device are presented. This device achieves an efficiency of 29.5% at a concentration of 102 suns.
Power devices such as MOSFETSs and IGBTs, include parasitic structures that can give rise to destructive failures such as breakdown and latch-up. To determine a suitable strategy for device radiation hardening, simulation software like MEDICI-2D can be used to model the effects of technological modifications and device parameters that are difficult to measure experimentally. (authors).
A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.
Achieving device independence for software applications is required for all but a small number of critical real time applications. Device independence is achieved by establishing protocols and building protocol interpreters for the specific devices. Data structures containing pointers to functions provide a flexible architecture for implementing protocol translation. 3 refs., 5 figs.
In the PV system with storage batteries, as a maximum power point tracking (MPPT) device is used to enhance battery charging, the enhancement must be greater than the internal loss of the device itself, or there will be no net gain at all. To evaluate the MPPT device benefits under different climate, the theoretical calculation models have been constructed. By simulation, a comparative study between two types of PV charge controllers with and without a MPPT device under different atmospheric conditions was presented. The comparison was made by means of the energy production obtained from the PV generator of each system. The climatic conditions of Beijing and Guangzhou in China have been regarded. From the results obtained it can be concluded that the effectiveness of the MPPT device in Guangzhou is not very obvious, however the MPPT device did greatly enhance ...
This paper presents a rationale for and a summary of tasks and missions to which mobile and stationary robots and other teleoperator-controlled devices could be assigned in response to the accidental release of radioactive and other hazardous/toxic materials to the environment. Many of these vehicles and devices currently support operation and maintenance of nuclear power plants and other nuclear industry facilities. This paper also discusses specific missions for these devices at the Three Mile Island and Chernobyl nuclear power plant sites at the time of the accidents. Also discussed is the status of devices under development for future applications, as well as research on robotics.
Choosing a medical device is complex and requires a transparent process based on reason, evidence and assessment of prioritized public health needs. Poor choices lead to inappropriate use or non-use of medical devices and a waste of resources.This report suggests how an agenda to improve access to appropriate medical devices could be devised from applying the crucial 4 components - Availability, Accessibility, Appropriateness, and Affordability, to the 15 global high-burden diseases and some cross-cutting issues. The results of this exercise suggest several areas of research necessary to help
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
The ACP Multi-Array Processor System (ACPMAPS) is a highly cost effective, local memory parallel computer designed for floating point intensive grid based problems. The processing nodes of the system are single board array processors based on the FORTRAN and C programmable Weitek XL chip set. The nodes are connected by a network of very high bandwidth 16 port crossbar switches. The architecture is designed to achieve the highest possible cost effectiveness while maintaining a high level of programmability. The primary application of the machine at Fermilab will be lattice gauge theory. The hardware is supported by a transparent site oriented software system called CANOPY which shields theorist users from the underlying node structure. 4 refs., 2 figs.
Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density magnetic storage systems.
Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density magnetic storage systems.
We have succeeded in aligning self-assembled structures by using a lithographically defined stripe. The 140 nm wide by 100 nm high SiO{sub 2} strip is shown to guide the assembly of 500 nm latex spheres so that spheres are aligned along the strip and are in registration on either side of the strip. This method can be used to increase long-range ordering in magnetic storage systems without compromising the density. Inverse sphere Ni arrays were made by electrodeposition through the latex template. We also show that the hexagonal symmetry of the resulting inverse sphere Ni arrays can be simulated using the approach presented below.
We have succeeded in aligning self-assembled structures by using a lithographically defined stripe. The 140 nm wide by 100 nm high SiO_2 strip is shown to guide the assembly of 500 nm latex spheres so that spheres are aligned along the strip and are in registration on either side of the strip. This method can be used to increase long-range ordering in magnetic storage systems without compromising the density. Inverse sphere Ni arrays were made by electrodeposition through the latex template. We also show that the hexagonal symmetry of the resulting inverse sphere Ni arrays can be simulated using the approach presented below.
We have succeeded in aligning self-assembled structures by using a lithographically defined stripe. The 140nm wide by 100nm high SiO2 strip is shown to guide the assembly of 500nm latex spheres so that spheres are aligned along the strip and are in registration on either side of the strip. This method can be used to increase long-range ordering in magnetic storage systems without compromising the density. Inverse sphere Ni arrays were made by electrodeposition through the latex template. We also show that the hexagonal symmetry of the resulting inverse sphere Ni arrays can be simulated using the approach presented below.
An array of sonic transducers, useful for medical ultrasonic imaging, has individual sections thereof separately coupled for forming separate beams of sonic energy which converge, respectively, to separate foci along a common axis of the beams. The ratio of the diameter of the radiating aperture of the array relative to a wavelength of the sonic energy is chosen to provide a moderate degree of focusing so that the depth of field at one focus blends with the depth of field of the next focus. Thereby, there is formed a continuous region of substantially uniform intensity of sonic radiation along the common beam axis. Circuitry is provided for selecting one or more specific foci dependent on the bounds of a selected region to be insonified. Upon reception of sonic energy, circuitry is provided for selecting one or more specific foci as a function of the time of travel of an echo from a subject being observed to approximate a continuously varying ...
The authors describe a small doubly reflecting research furnace. Its optical components, a heliostat and a concentrating array of hexagonal-in-plan-form mirrors, focus sunlight at the aperture of a cavity receiver. A perfect paraboloid of revolution would have given higher concentration ratios. But large paraboloids are difficult to make and manipulate. Small hexagons are convenient and can be close packed. Spherical mirrors centered on a sphere simplified construction and were economical. In this note they use a simple model to describe the radial distribution of the normal flux at the focus of such an array. A schematic representation of a cross section of the concentrator mirror array in a plane which includes its axis is shown.
A mass separated focused ion beam (FIB) is a very useful tool to fabricate nanostructures by writing implantation within an ion beam synthesis process. In these investigations the IMSA-OrsayPhysics FIB, equipped with a Co_3_6Nd_6_4 alloy liquid metal ion source, was applied. Si(100) and (111) wafers were implanted with 60 keV Co"+"+ ions in the dose range of 2 . 10"1"6 to 2 . 10"1"7 cm"-"2. Implantation parameters were investigated, like pixel dwell time, relaxation time (time between two cycles), dose rate as well as the pixel overlapping factor. The subsequent annealing was done in a two step process, namely 600 deg. C for 60 min and 1000 deg. C for 30 min in a N_2 ambient. The results obtained by SEM investigations in terms of continuous nanowire structures following the direction and interrupted CoSi_2 pattern in the direction show a clear dependence on the time scale as well as the scanning mode of the irradiation. Structure sizes as small as 10 nm are ...
Autophagy is a ubiquitous catabolic process that ensures organism’s well-being by sequestering a wide array of undesired intracellular constituents into double-membrane vesicles termed...Full Text Available
Ultraviolet light can be used to immobilize biomolecules onto thiol reactive surfaces in order to, e.g., make biosensors. The mechanism involves light-induced formation of free, reactive thiol groups in disulphide containing molecules. This technology allows for the creation of arrays of biomolecules with a high degree of reproducibility, circumventing the need for often expensive nano/micro-dispensing technologies. The ultimate size of the immobilized spots is defined by the focal area of the UV beam. Light-induced immobilization has the added benefit that the immobilized molecules will be spatially oriented and covalently bound to the surface. In this paper, we demonstrate the utility of a sensor array created with the new sensor technology when integrated into a microfluidic system. Protein arrays made using light-induced immobilization showed successful antigen/antibody binding in a flow cell allowing the visualisation ...
... F.; Murray, R. W. J. Am. Chem. ... 14. Thackeray, J. W.; White, H. S.; Wrighton, M. SJ Phys. ... Dr. James S. Murday (1) Dr. Harold H. Singerman (i) ...
p53 is one of the most mutated tumor suppressors in human cancers and as such has been intensively studied for a long time. p53 is a major orchestrator of the cellular response to a broad array...Full Text Available
Purpose.Since 2002, six blind patients have undergone implantation of an epiretinal 4 × 4 electrode array designed to directly stimulate the remaining cells of the retina...Full Text Available
A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in ...
Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available
The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a ...
The neuronal networks in spinal cord can produce a diverse array of motor behaviors. In aquatic vertebrates such as fishes and tadpoles, these include escape behaviors, swimming across a range...Full Text Available
Polyploidy is an important force in the evolution of flowering plants. Genomic merger and doubling induce an extensive array of genomic effects, including immediate and long-term alterations in the...Full Text Available
An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique.
The lung has the potential of metabolizing many foreign chemicals to a vast array of metabolites with different pharmacological and toxicological properties. Because many chemicals require metabolic...Full Text Available
A free standing outdoor telephone booth is provided with a photovoltaic (PV) array, one or more rechargeable storage batteries and electrical control circuit which includes a temperature compensated control for limiting the supply of electrical energy from the PV array to the rechargeable battery to avoid over charging the battery, an ambient light (solar insolation) sensing circuit for controlling the electrical lamp load, to turn the lamp ON during dark ambient and OFF during light ambient conditions. In addition, the total discharge limit of the storage battery is controlled to a safe operating limit and a means is disclosed to power a fluorescent lamp at energy conserving intensities with energy derived from the rechargeable storage battery. The lamp control circuitry is preferably constituted by a high frequency power inverter with regulated output power to energize a low wattage fluorescent lamp and to dim the fluorescent lamp when the ...
The analysis of individual molecules is evolving into an important tool for biological research, and presents conceptually new ways of approaching experimental design strategies. However, more...Full Text Available
Objectives1. The study of the automatic alignment of electrically charged optical fibres.~%~~%~2. The design and construction of a prototype system for assembly of the fibres.~%~~%~3. The fabrication of a proof-of-principle 4-by-4 fibre array.~%~~%~4. The test and characterisation of the prototype fibre bundle in terms of translational and angular positioning accuracy.~%~~%~5. A paper design of a full-scale automated system.~%~~%~6. Enable commercial exploitation.~%~DescriptionThis multidisciplinary programme aims to investigate and develop an 'adventurous' process for manufacturing 2-D optical fibre arrays, with at least an order of magnitude improvement in the positional and angular tolerances of the mono-mode fibres compared to conventional techniques. Manufacturable, dense 2-D optical fibre arrays are essential for a wide variety ...
AimsThe aims of the study were to study the effect of pre-operative treatment on the expression of tumour-related proteins and to correlate the expression of these...Full Text Available
Norway spruce (Picea abies L. Karst) produces an oleoresin characterized by a diverse array of terpenoids, monoterpenoids, sesquiterpenoids, and diterpene resin acids that can protect...Full Text Available
Integration of solid-state biosensors and lipid bilayer membranes is important for membrane protein research and drug discovery. In these sensors, it is critical that the solid-state sensing...Full Text Available
Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer ...
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...
New developments in fluorophores as well as in detection methods have fueled the rapid growth of optical imaging in the life sciences. Commercial widefield microscopes generally use arc lamps, excitation/emission...Full Text Available
Gene arrays containing all currently known open reading frames of Bacillus subtilis were used to examine the general stress response of Bacillus. By proteomics, transcriptional...Full Text Available
Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two ...
Most wind farms consist of horizontal axis wind turbines (HAWTs) due to the high power coefficient (mechanical power output divided by the power of the free-stream air through the turbine cross-sectional area) of an isolated turbine. However when in close proximity to neighboring turbines, HAWTs suffer from a reduced power coefficient. In contrast, previous research on vertical axis wind turbines (VAWTs) suggests that closely spaced VAWTs may experience only small decreases (or even increases) in an individual turbine's power coefficient when placed in close proximity to neighbors, thus yielding much higher power outputs for a given area of land. A potential flow model of inter-VAWT interactions is developed to investigate the effect of changes in VAWT spatial arrangement on the array performance coefficient, which compares the expected average power coefficient of turbines in an array to a spatially isolated turbine. A geometric arrangement ...
Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were evaluated primarily for ...
Laser holographic interferometry and pressure measurements are presented for the effects of rib-to-duct height ratio (H/2B), rib pitch-to-height ratio (Pi/H), and Reynolds number (Re) on the spatially periodic-fully developed turbulent heat transfer and friction in a rectangular duct of width-to-height ratio of 4:1 with an array of ribs detached from one wall at a clearance to rib-height ratio of 0.38. The ranges of H/2B, Pi/H, and Re examined were 0.13 to 0.26, 7 to 13, and 5 {times} 10{sup 3} to 5 {times} 10{sup 4}, respectively. The difference in the H/2B dependence of the thermal performance between the detached and attached solid-rib array is documented H/2B = 0.17 and Pi/H = 10 are found to provide the best thermal performance for the range of parameters tested. Compact heat transfer and friction correlations are developed. Additionally, it is found that heat transfer augmentation with a detached solid-rib array is ...
Photon migration provides sensitive tissue oximetry in which the optical pathlength is known. Phase array gives the precise location of a subnanomolar amount of hidden absorber in highly scattering medium. PMID:8079713
Species of the large family Orchidaceae display a spectacular array of adaptations and rapid speciations that are linked to several innovative features, including specialized pollination syndromes,...Full Text Available
The zebrafish is emerging as a prominent model system for studying the genetics of human development and disease. Genetic alterations that underlie each mutant model can exist in the form of...Full Text Available
An impinging jet is a widely used technique for realizing high heat-transfer rates between a fluid and a surface. However, the area of enhanced heat transfer is limited to the neighborhood of the stagnation point. In this study, heat transfer is augmented remote from the stagnation point in an impinging plane jet system by a rod array located near the wall. Each square rod in the array was positioned normal to the flow direction and parallel to the flat plate surface. The distance between the nozzle and the flat plate (H) and the spacing between the rods and the flat plate surface (C) were changed to find the optimum values. The largest heat-transfer augmentation was obtained for C = 1 mm, H/B = 10, where the jet nozzle width is B. In this case, the heat-transfer coefficient averaged over an area 2B from the stagnation point is about 1.6 times greater compared to that without a rod array.
An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique. (orig.).
BackgroundThe commonest pathogenic DMD changes are intragenic deletions/duplications which make up to 78% of all cases and point mutations (roughly 20%) detectable...Full Text Available
Feasibility of depositing continuous films of nano-porous alumino-silicates, primarily zeolites and MCM-41, on metallic and non-metallic substrates was examined with an aim to develop membranes for separation of gaseous mixtures and also for application as hydrogen storage material. Mesoporous silica was deposited in-side the pores of these nano-porous disks with an aim to develop membranes for selective separations. Our study involves supported zeolite film growth on substrates using in-situ hydrothermal synthesis. Faujasite, Silicalite and Mesoporous silica have been grown on various metallic and non-metallic supports. Metallic substrates used for film growth included anodized titanium, sodium hydroxide treated Titanium, Anodized aluminum, and sintered copper. A non-metallic substrate used was nano-porous aluminum oxide. Zeolite film growth was characterized using Scanning Electron Microscope (AMRAY 1820) and High Resolution Transmission electron microscope. Silicalite was found to ...
A 4{pi} detection system sensitive to light charged particles is being developed at the Laboratori Nazionali di Legnaro (LNL) for the study of reaction mechanisms at energies up to 20 AMeV. The array consists of 262 {Delta}E-E telescopes covering 90% of 4{pi}. Each telescope is made of a 300 {mu}m passivated silicon detector and a 15 mm (or 5 mm) CsI(Tl) crystal read by a photodiode. The system will be operational in the Spring of 1997 and the first experiments will run in the second half of 1997.
Single-shot spin-echo diffusion-weighted echo-planar imaging using a phased-array multicoil was performed to distinguish between normal and cirrhotic livers. Sets of 6 images with different b-value were acquired with breath-holding. Significant differences were observed between controls and cirrhosis cases in the signal ratios when the b-value was 383 s/mm{sup 2}, and apparent diffusion coefficients. (orig.)
With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.
High-power diode laser arrays emitting at 690 nm have been developed for solid-state laser pumping. The laser diode bars (fill factor [approx]0.7) have been fabricated from single quantum well AlGaInP-based heterostructures. Using silicon microchannel heatsinks, a record high 360 W/cm[sup 2] per emitting aperture is achieved under continuous wave operation.
This is a design study into the capabilities of the Australian Square Kilometre Array Pathfinder (ASKAP) in performing a full-sky low redshift neutral hydrogen survey, termed WALLABY, and the potential cosmological constraints one can attain from measurement of the matter power spectrum. We find that the full sky survey will likely attain 600,000 redshifts which, when combined with expected Planck CMB data, will constrain the Dark Energy equation of state to 20%, for the first time making cosmological constraints from radio observations competitive with the best existing optical surveys.
The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.
The theoretical performance of ideal single- and multijunction cells are compared at 100xconcentration under a range of cloudless-sky conditions. The sensitivities of device performance to cell temperature and spectral variations are shown to depend on the number of junctions (one, two or three), the way in which the junctions are connected (series, parallel or independent), and the band gaps of the devices. The average performances of all of the multijunction devices surpass that of a single-junction GaAs device, but the inconsistency in performance of some of the multijunction devices is significant for large variations in cell temperature and incident spectrum. The choice of band gap and connection scheme is more important than the number of junctions in determining the consistency of device performance. (orig.).
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles ...
A feasibility study test and 3 field trials were performed at Darlington NGS in 1996, 1999 and 2000 on ABB LP turbines. The scope of these trials was to commission in-situ automatic phased array systems capable to inspect blade roots and rotor steeples of L-0 and L-1 rows. GE disk-blade rim attachments were inspected at Bruce B nuclear station, in fall of 1999. The automated ultrasonic phased array technology is capable of high-speed rate and reliable detection and sizing. The capability demonstration was performed on mock-ups and reference blocks, using EDM notches. A custom built UT simulation software: Imagine 3D interfaces with SimScan to generates the spreadsheets/charts with target and probe coordinates and ultrasonic path and angles (refracted and skew) to hit the reference target. Examination of L-0 blade and rotor steeple grooves was performed with 2 phased array systems under networking. Data analysis was done in ...
Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available
Science and technology could be revolutionized by quantum computers, but building them from solid-state devices will not be easy. Robert W Keyes of IBM's research division outlines the challenges in scaling up the technology from lab experiments to practical devices. (U.K.)
... Biomedical Engineering Optical and Photonic Materials and Devices Fundamental Optical Interactions ... of Texas Medical School OPTICAL AND PHOTONIC MATERIALS AND DEVICES Gary Bjorklund, IBM, Chair Nan ...
The patent relates to fluid operated devices for moving articles. The machine may be used in filling a nuclear fuel canister with fuel pellets where there is a tendency for out of squareness of pellets to produce a jam condition readily cleared by a modest force. (U.K.).
A device for reducing the muzzle blast and flash from large caliber guns is disclosed. A container having a plurality of internal chambers and baffle plates filled with an aqueous foam is mounted to the muzzle of the gun barrel. The foam and chambers co-o...
Coke-fired cupola furnaces were improved and made suitable for the production of high-quality casting melts by numerous additional devices. Moreover, they were equipped with environmental protection systems with numerous dust separation devices and afterb...
The purpose of this study was to determine whether the use of wheeled mobility devices differed with respect to age, gender, residential setting, and health-related factors among older adults. A total...Full Text Available
In this paper we discuss the effect on the emittance of the residual dispersion in the insertion devices. The dispersion in the straights could be generated by the lattice error, trim dipole, and insertion device. The effect on the emittance is examined, and the dispersion tolerances are given for the NSLS-11.
This design manual contains descriptions of design procedures and operating experience to date, including results obtained, for secondary flow pollution control devices. Two types of combined sewer overflow regulators are described: the swirl and the helical bend regulator/separa...
The biomechanical nature of the arterial system and its major disease states provides a series of challenges to treatment strategies. Endovascular device design objectives have mostly centered on short-term...Full Text Available
BackgroundDuring surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device...Full Text Available
...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...
The influence of the main factors on device efficiency of pulsed liquid jet pump with gas-liquid piston is analysed, the theoretical equation and its time-averaged solution of pulsed liquid jet pump device efficiency are derived. The theoretical and experimental results show that the efficiency of transmission of energy and mass to use pulsed jet is greatly raised, compared with steady jet, in the same device of liquid jet pump. The calculating results of time-averaged efficiency of pulsed liquid jet pump are approximately in agreement with the experimental results in our and foreign countries
Advanced techniques for focused-ion-beam (FIB) device modification have been developed for complex, multistep modifications to circuitry on planar chip technology. Applying gas-assisted etching (GAE) techniques for high-aspect-ratio milling and the selective milling of both conductive and insulating films enhances process latitude. Localized ion-beam-induced deposition of an insulating film provides reconstructive capability in previously modified areas. The application of both techniques for complex device modification on VSLI devices fabricated with CMOS process technology is reviewed. (UK).
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.
This paper discusses design considerations for the recently introduced GaInP/GaAs monolithic tandem concentrator cell. The prototype device achieves a peak efficiency of 30.2% in a range of 140--180 suns, making this the first two-terminal device to demonstrate a verified efficiency exceeding 30%. At 425 suns the efficiency is still above 29%. The authors focus on the issues of grid design, top-cell thickness, and antireflectance coat. They also examine ways in which these aspects of the device may be modified to provide further performance improvements for future devices.
sabot: A device fitted around or in back of a projectile in a gun barrel or launching tube to support or protect the projectile or to prevent the escape of ...
The individuality of production devices should be taken into account when statistical models are designed for parallelized devices. In the present work, a new clustering method, referred to as NC-spectral clustering, is proposed for discriminating the individuality of production devices. The key idea is to classify samples according to the differences of the correlation among measured variables, since the individuality of production devices is expressed by the correlation. In the proposed NC-spectral clustering, the nearest correlation (NC) method and spectral clustering are integrated. The NC method generates the weighted graph that expresses the correlation-based similarities between samples, and the constructed graph is partitioned by spectral clustering. A new statistical process monit...
A slurry intake device is proposed which contains an inlet sleeve, housing with grating installed with the discharge end in the zone of the slurry outlet, and hinged deflector. In order to conserve the clay mud, it is equipped with a tie rod and two-arm lever which is kinematically linked to the deflector and the grating. It is installed by hinges in relation to the housing and the latter is attached by hinges to the inlet sleeve. The deflector is arranged in the zone of slurry outlet. The device is distinguished by the fact that the deflector is equipped with a cantilever on which a fixable weight is attached.
Resistance exercise has been widely reported to have positive rehabilitation effects for patients with neuromuscular and orthopaedic conditions. This paper presents an optimal design of magneto-rheological fluid dampers for variable resistance exercise devices. Adaptive controls for regulating the resistive force or torque of the device as well as the joint motion are presented. The device provides both isometric and isokinetic strength training for various human joints.
A self-organizing particle swarm is presented. It works in dissipative state by employing the small inertia weight, according to experimental analysis on a simplified model, which with fast convergence. Then by recognizing and replacing inactive particles according to the process deviation information of device parameters, the fluctuation is introduced so as to driving the irreversible evolution process with better fitness. The testing on benchmark functions and an application example for device optimization with designed fitness function indicates it improves the performance effectively.
A method and apparatus is provided for detecting explosives by thermal imaging. The explosive material is subjected to a high energy wave which can be either a sound wave or an electromagnetic wave which will initiate a chemical reaction in the explosive material which chemical reaction will produce heat. The heat is then sensed by a thermal imaging device which will provide a signal to a computing device which will alert a user of the apparatus to the possibility of an explosive device being present.
The audible noise produced by corona on high-voltage transmission lines has several characteristics that differentiate it from other community noises. Transmission line noise is quite broadband and has a significant high frequency content. Special instrumentation designed to measure this type of noise pollution is described. All measuring systems have the same three basic elements: a transducer, a processing device, and an output device. Recorders, microphone devices, frequency analyzers, and meteorological instrumentation are discussed.
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
The dynamic behavior of electrooptic bistable devices with delayed feedback is investigated theoretically and experimentally. The operation principle of the system is analyzed by the method of iterated maps. Stable, bistable, periodic, higher periodic, and chaotic solutions are discussed and realized experimentally by using an integrated Mach-Zehnder interferometer on LiNbO3 as a basic nonlinear element. Taking into account the periodic modulator characteristic, the application of this device as a simple and fast bistable and monostable multivibrator is demonstrated. In addition, the synchronization properties of the astable multivibrator are investigated.
The purpose of the invention is to increase reliability in the operation of the device for advancing the base of a stoping unit. This is achieved because the device includes alternation hydraulic jacks of advance and control connected by hinges between themselves by the sections of the base and equipped with hydraulic locks, distributors of the hydraulic jacks of advance. In this case the hydraulic locks connected to the hydraulic jacks of control are doubled and connected to the distributors of the neighboring sections through reverse valves.
This is a patent for a device to increase compaction of the loaded batch in a coking chamber that assures a balanced compaction of the batch from the upper to the bottom layer. The leveling rod has a device on the external end that causes the rod to shift vertically and bring pressure on the material and the pressing attachment. Opposite the loading hoppers of the coking chambers there are guides that ensure the rod will be sunk perpendicularly into the loaded material.
Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)
The invention concerns a container for the long term storage of irradiated nuclear reactor fuel elements, which consists mainly of a basic body, at least one lid and an outside ring shaped lid tightening device, which acts on the basic body and the lid and holds the contact surface of the lid tight against the contact surface of the basic body, where the basic body, lid and the lid tightening device consist of corrosion-proof materials. (orig./HP).
Large scale flows of liquids can be controlled by using power fluidic devices that harness the hydrodynamic properties of liquids rather than use moving parts. Included among the fluidic devices considered are fluidic pumps, reverse flow diverters, fluidic diodes and vortex amplifiers. These devices are of potential use in the nuclear industry, particularly in reprocessing. (U.K.).
The purpose of the invention is to simplify assembly and to reduce labor intensity. This is achieved by the fact that the assembly shaft is positioned in a hawser, while its wall which is turned towards the body of the installation is combined with the hawser wall, where a U shaped opening is made in the wall of the assembly shaft, along the edges of which there is a hermetically sealing device, while the bottom of the body of the offshore drilling rig is equipped with a rigid insert attached with the capability of adjoining it with the hermetically sealing device.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).
We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.
A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat frequencies unique to the acoustical signatures of these species as an indication of the ...
This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.
An electronically controllable apparatus is described which modulates a continuous wave laser beam so as to produce an output beam consisting of coherent ''pulses'' that are electronically controllable as to both pulse repetition rate and pulse width. The apparatus includes two acoustic devices positioned so that the laser beam passes through them in sequence, and apparatus or for passing sound waves through the devices to frequency shift the laser radiation as well as to diffract it. Each acoustic device such as generates sound waves containing a group of frequencies which result in spaced pulses. The spreading of a laser beam at which emanates from the first acoustic device is countered by the second acoustic device to produce a collimated, coherently pulsed, laser beam.
The effects of upwind turbine wakes on the performance of a FloWind 17-m VAWT were investigated through a series of field experiments conducted at the FloWind windfarm on Cameron Ridge, Tehachapi, California. The field experiment was conducted within a VAWT array consisting of more than nine VAWTs with separations 3D crosswised by 8D downwind (where D is the turbine diameter) in a staggered configuration. The array is the upwind three rows of VAWTS in a total of six rows that are on top of the Cameron Ridge plateau. The terrain features in the vicinity are reasonably regular, with an upslope of 7 deg on the average; however, several local irregularities are present. The annual hourly averaged wind speed exceeds 8 m/s at the site. The wind field and the power-outputs of nine turbines within the array were measured with wind sensors and power transducers. Nine Gill propeller and 18 Maximum cup anemometers and one direction ...
To overcome the limitations of conventional bobbin style eddy-current probes, it has become common practice to perform some portion of a steam generator tube inspection program with array coil probes. Typically, eight surface-riding pancake coils are utilized in a probe head, either as eight independent coils (8 x 1) or in a parallel combination of four serially connected coils (4 x 4). The advantages of the array coils are improved sensitivity to intergranular attack (IGA), reduced interference from tube denting, and improved sensitivity to circumferential cracking. The current status of commercially available probes is such that several weaknesses in array coils have limited the widespread application of this technology. Task S 301-6 was conceived to address each of the weaknesses in order to produce a more reliable and cost-effective probe. The emphasis was on reliability, since the cost associated with downtime for a ...
The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the ...
This article describes a flexible and extensible infrastructure for applying Web-Technologies to embedded systems.The presented approach develops a Three-level-Architecture consisting of the embedded system, the universal Remote-Access-Server and the Remote-Access-Client. A system-spanning general interface allows the binding of embedded systems in order to access their process data. Additionally, this procedure facilitates a flexible processing of the device data, so that it is ready to be used by different control devices. To ensure flexibility - connecting different devices on the one side and providing information for different clients like PC, PDA or mobile phone on the other side - a new XML-based description language (Service Description Markup Language - SDML) is introduced. The SDML documents contain information about connected embedded systems, reusable device data and the presentation ...
An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during ...
Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of neutron and gamma ray transport calculational ...
This paper presents (a) an overview of the Inmos transputer and its use in parallel arrays for image processing, (b) a functional block-level description of IBM-AT-compatible boards for signal/image processing research using transputers with reconfigurable interconnection topologies, and (c) an overview of the OCCAM and C programming tools for placing parallel algorithms onto such a processor. The hardware consists of two custom printed-circuit boards (and two commercially available boards) within an IBM-AT host. The first provides a flexible input/output interface between a general-purpose high-speed input-data bus and the transputer array. The second contains 32 transputers and 4 programmable crossbar-switch interconnection chips. Several copies of the second board can be cascaded (or even partially-unpopulated) to provide for an arbitrary number of transputer chips. Each one of these boards will perform about 128 million Whetstones or, for ...
The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the package is based on a numerical ray ...
Ga"+ focused ion beam (FIB) patterning was used to structure highly oriented pyrolytic graphite surfaces with square, periodic arrays of amorphous carbon defects (mesh sizes: 300 nm-2 #mu#m). Controlled oxygen etching of these arrays leads to matrices of uniform, orientationally aligned, nm-sized, hexagonal holes. The properties of the resulting hole assembly (hole depths and lateral hole dimensions) have been investigated by means of atomic force microscopy, scanning electron microscopy and FIB sectioning. The hole dimensions and uniformity both depend on the FIB parameters and etching conditions. Etching temperatures from 500 to 700 deg. C were applied. Initial etch rates of up to 10"6 C s"-"1 per individual hole were observed when using oxygen pressures of 200 mbar. For an etch temperature of 590 deg. C the rate of etching of individual holes was found to depend measurably on the inter-hole separation. This confirms that the associated ...
An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is kept at safe levels by enclosing the analyser within shielding ...
The use of borated plaster to isolate uranium (93.2 wt % /sup 235/U) metal was studied in a series of subcritical experiments with uranium metal cylinders (7.0 in. diam, 2.0 in. thick) and slabs (approx.1.4 x approx.5.4 x approx.10.1 in. dimensions). In the cylindrical experiments, the thickness of borated plaster was varied up to 10 in. and the subcriticality measured using the /sup 252/Cf-source-driven neutron noise analysis method. In the experiments with the uranium slabs, an array of slabs 3 wide and 8 high was assembled in steps to demonstrate the subcriticality of this array with 3.75-in.-thick borated plaster as an isolating material between all uranium slabs. In the slab experiments, both noise analysis and source neutron multiplication measurements were performed. Before assembly of the slab array the presence of boron in the plaster was verified by neutron transmission and gamma-ray spectrometry measurements.
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of ...
The Heard Island Feasibility Test (HIFT) demonstrated that coded acoustic signals could be detected at ranges up to 18,000 km with currently available source technology. This paper describes one component of the HIFT where a large aperture vertical line array was deployed to record the signals transmitted from Heard Island. We have performed four analysis Of the VLA receptions, of the Heard Island signals. All four suggest the presence of higher order modes. The frequency- vertical wavenumber analysis and the modal beamforming indicate that mode 3 has the highest amplitude while the modal fitting suggests that made 5--6 are largest. It is difficult to resolve the differences since the SNR at the VLA, nearly 18,000 km with a transmission loss of around 145 dB, is quite low. Individual arrivals could not be distinguished because of the long integration time necessitated by the low SNR.
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
As in all vehicles of this type, low weight and aerodynamic drag must be achieved without compromising safety, and in an extremely rugged structure. This has been done by using a chrome-molybdenum steel space-frame, surrounded by a Kevlar/foam sandwich body shell. The solar panel wing, which uses a laminar flow section to obtain low drag, does not tilt except when the vehicle is stationary. A high degree of redundancy is built into the vehicle; for example there are two motors and transmissions, the solar array is divided into seven parallel sub-arrays, and the power electronics is multiply redundant. Built entirely in the garage of a suburban house, the Australian Geographic Team Marsupial car cost less than US$50,000 to construct.
The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be extremely weak and higher S/N of {approx}10{sup 4} or more is required to detect the magnetic scattering of this material.
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be extremely weak and higher S/N of ?104 or more is required to detect the magnetic scattering of this material.
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was ...
The present conference on lens design encompasses physical and geometrical optics, diffractive optics, the optimization of optical design, software packages, ray tracing, the use of artificial intelligence, the achromatization of materials, zoom optics, microoptics and GRIN lenses, and IR lens design. Specific issues addressed include diffraction-performance calculations in lens design, the optimization of the optical transfer function, a rank-down method for automatic lens design, applications of quadric surfaces, the correction of aberrations by using HOEs in UV and visible imaging systems, and an all-refractive telescope for intersatellite communications. Also addressed are automation techniques for optics manufacturing, all-reflective phased-array imaging telescopes, the thermal aberration analysis of a Nd:YAG laser, the analysis of illumination systems, athermalized FLIR optics, and the design of array systems using shared symmetry.
A wavelength division multiplexer/demultiplexer having optical path lengths between a fiber array and a Fourier transform lens, and between a dispersion grating and the lens equal to the focal length of the lens. The optical path lengths reduce losses due to angular acceptance mismatch in the multiplexer. Close orientation of the fiber array about the optical axis and the use of a holographic dispersion grating reduces other losses in the system. Multi-exposure holographic dispersion gratings enable the multiplexer/demultiplexer for extremely broad-band simultaneous transmission and reflection operation. Individual Bragg plane sets recorded in the grating are dedicated to and operate efficiently on discrete wavelength ranges.
In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)
The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)
Unmanned Aerial Vehicles (UAV) are being proposed for many applications including surveillance, mapping and atmospheric studies. These applications require a lightweight, low speed, medium to long duration airplane. Due to the weight, speed, and altitude constraints imposed on such aircraft, solar array generated electric power is a viable alternative to air-breathing engines. Development of such aircraft is currently being funded under the Environmental Research Aircraft and Sensor Technology (ERAST) program. NASA Lewis Research Center (LeRC) is currently building a Solar Electric Airplane to demonstrate UAV technology. This aircraft utilizes high efficiency Applied Solar Energy Corporation (ASEC) GaAs/Ge space solar cells. The cells have been provided by the Air Force through the ManTech Office. Expected completion of the plane is early 1995, with the airplane currently undergoing flight testing using battery power.
During the 2007 Niigataken Chuetsu-oki earthquake, strong ground motion with the peak acceleration of 680 cm/s/s which was larger than that of the empirical prediction was recorded at the base mat of the No.1 reactor building of Kashiwazaki-Kariwa Nuclear Power Station (NPS). Furthermore, in the Kashiwazaki-Kariwa NPS, over twice difference of 680 vs. 322 cm/s/s of peak acceleration between the No.1 and the No.6 reactor buildings was observed on the base mat. From the results of recent research, it is suggested that the deep sedimentary layers can be one of the important factors to elucidate these phenomena. In this study, at first, the applicability of microtremor array measurements for estimation of deep S-wave velocity structure (#approx#Vs=3 km/s layer) are discussed. Vertical microtremors were observed in three arrays at the Kashiwazaki-Kariwa NPS with the maximum station spacings of 3.04 km, 1.49 km and 0.75 km, respectively. The Rayleigh ...
Using a realistic three-body model, angular distributions for the "1"6O(d,p)"1"7O(1/2"+) reaction, based on the channel coupling array (CCA) theory and various forms of the coupled reaction channel (CRC) method are compared. Despite the different forms and theoretical foundations of these methods, they yield similar angular distributions, within the bound state approximations used herein. The expected breaking of time reversal inveriance in the approximated CCA theory is quite small over most of the angular range. Of all the methods used, coupling effects in the forward directions are largest for the post form of the CRC, indicating that it is the least reliable of the CRC forms for fitting data. (Auth.).
Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the individual channel correlation traces to achieve significant ...
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
The problem of passively tracking a moving signal source has importance in a variety of applications such as radar, sonar, seismology, and radio astronomy. In many applications, only limited information is available about the signal source. It will be assumed here that only the signals which are detected by the sensors and the velocity of the source signal are known. The objective of this document is to present a program which passively tracks a target using an array of sensors. This program is available in MATLAB, version 3.5. The algorithm which is implemented consists of three main parts: time delay estimation, passive localization, and data post processing. Each of these parts are discussed, and the mathematical foundation for their solution given. Following, this the organization of the program is presented, and an example of its usage is given.
Abstract Surface modification of topography and chemistry in order to achieve a specific water contact angle (CA) has been explored by using a novel combinatorial screening platform. The screening arrays consisted of 507 distinct combinations of micro-topographies and chemical compositions. By performing chemical modifications with 1H, 1H, 2H, 2H perfluoroethyltriethoxy-silane (PFS) and n-octadecyltriethoxysilane (ODS) on standard silicon wafers it was possible to include both superhydrophobic and very hydrophilic pad arrays in the same screening platform. Surfaces modified with PFS were more hydrophobic than surfaces modified with ODS, while the unmodified silicon surfaces were hydrophilic. For the PFS modified surfaces the largest CAs were achieved with a small pillar size of X-=-1-m and...
Since information has been regarded os a physical entity, the field of quantum information theory has blossomed. This brings novel applications, such as quantum computation. This field has attracted the attention of numerous researchers with backgrounds ranging from computer science, mathematics and engineering, to the physical sciences. Thus, we now have an interdisciplinary field where great efforts are being made in order to build devices that should allow for the processing of information at a quantum level, and also in the understanding of the complex structure of some physical processes at a more basic level. This thesis is devoted to the theoretical study of structures at the nanometer-scale, 'nanostructures', through physical processes that mainly involve the solid-state and quantum optics, in order to propose reliable schemes for the processing of quantum information. Initially, the main results of quantum information theory and quantum ...
The lateral bearing device is made of 7 lateral supports, each positioned to allow the displacement of the steam generator due to thermal or seismic effects. Each support includes a buffer plate that can be positioned on the steam generator using a position control assembly. This control assembly consists of a screw jack arrangement where the nut is fastened via an energy absorbing layer to a footplate that is fixed to the concrete wall of the steam generator enclosure. 4 figs.
We have investigated tailoring damage effects of explosive devices by addition of unconventional materials, specifically combustible metals. Initial small-scale as well as full-scale testing has been performed. The explosives functioned to disperse and ignite these materials. Incendiary, enhanced-blast, and fragment-damage effect have been identified. These types of effects can be used to extend the damage done to hardened facilities. In other cases it is desirable to disable the target with minimal collateral damage. Use of unconventional materials allows the capability to tailor the damage and effects of explosive devices for these and other applications. Current work includes testing of an incendiary warhead for a penetrator.
High power and particle deposition on target materials are encountered in many applications including magnetic and inertial fusion devices, nuclear and high energy physics applications, and laser and discharge produced plasma devices. Surface and structural damage to plasma-facing components due to the frequent loss of plasma confinement remains a serious problem for the Tokamak reactor concept. The deposited plasma energy causes significant surface erosion, possible structural failure, and frequent plasma contamination.
Advances in the development of several electrooptic shutter devices utilizing the quadratic electrooptic effect of lead lanthanum zirconate titanate (PLZT) ceramic wafers are described. Aperture sizes utilized in these PLZT devices ranged from 25 ..mu..m to 0.25 m. Practical applications of the shutters discussed in this paper include eye protection in military and industrial applications, a goggle-type device with dual synchronously operated PLZT shutters for use in a stereoscopic three-dimensional TV display, an electrically controlled variable density filter for use with vidicon tubes, a large-aperture photographic shutter for image motion compensation cameras, and a page composer for use in a holographic memory system.
Recently, organic semiconducting materials have gained a broad interest due to their potential for organic electronic devices such as organic light emitting diode (OLED), organic photovoltaic devices and organic field-effect transistors (OFETs). Optical properties of organic semiconducting materials are important for practical application. For example, the power conversion efficiency of organic photovoltaic devices is mainly affected by absorption properties of organic materials. Proton irradiation is one of the efficient methods to change the optical properties of organic materials. In this paper, we investigate the changes of optical properties of various polymers using the proton irradiation.
The saturation of free electron laser (FEL) output power by the KHI-FEL device was achieved on 3rd, October 2000 at the wavelength of 9.3 #mu#m. The FEL device has operated thereafter successfully in the wavelength region between 4.0 and 16.0 #mu#m. The macropulse average FEL power of 37.5 kW, which is the theoretical saturation level, has been obtained at the wavelength of 7.9 #mu#m. The net FEL gain was estimated to be 16%. (author)
Experimentally it is shown that a movable grounded metallic plate placed inside a multi-dipole magnetic cage can vary the diffused plasma parameters such as density, plasma potential and electron temperature. Plasma is solely produced in the source section of a double plasma device by a dc hot filament discharge and a low-density plasma is produced in the target section by local ionization of neutral gas by the high energetic electrons coming from the source section. A grounded movable stainless steel plate is inserted in the target section of the device. The floating potential of the plate also changes depending on the position of the plate inside the magnetic cage.
The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.
The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.
In the well-known devices for increasing the decontamination factor in the treatment of radioactive waste water by evaporation, which consist of narrowing devices with evaporator sump and condenser, droplets of liquid and solid particles are carried over from the breeder space, which are radioactive and therefore make the decontamination factor worse. Better results are obtained if one places a fibre bed filter between the evaporator sump and the condenser, preferably in a horizontal connecting pipe between the evaporator sump and the condenser.
A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.
A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.
... The acousto-optic device have a 30 MHz 1 ... coherent systems including compact non-coherent optical ... a relatively simple phase switching approach. ...
BackgroundThe routine removal of orthopaedic fixation devices after fracture healing remains an issue of debate. There are no evidence-based guidelines on this matter, and little...Full Text Available
... electronic feedback system' connected to a Q switch ... The use of acousto-optic (AO) beam steering devices for BMDO (SDI) applications is very ...
A silicon solar cell assembly comprising a large, thin silicon solar cell bonded to a metal mount for use when there exists a mismatch in the thermal expansivities of the device and the mount.
Introduction: Patients in underdeveloped nations have limited access to life-saving medical technology including cardiac rhythm management (CRM) devices. We evaluated alternative means to provide such technology to this patient population while assessing the safety and efficacy of such a practice. Methods: Patients in the United States with clinical indications for extraction of CRM devices were consented. Antemortem CRM devices were cleaned and sterilized following a protocol established at our institution. Surveillance in vitro cultures were performed for quality assurance. The functional status of pulse generators was tested with a pacing system analyzer to confirm at least 70% battery life. Most generators were transported, in person, to an implanting institution in Nicaragua. Recipien...
We report on studies of device degradation in organic photovoltaic devices based on blends of poly(3-hexylthiophene) (P3HT) and [6,6]-phenyl C61-butyric acid methyl ester (PCBM). Since delamination, oxidation, and chemical interactions at the metal electrode/organic interface have long been posited as degradation pathways in organic electronic devices, we first investigated the stability of a variety of electrodes for devices stored in an inert, dark environment. Second, a set of experiments was designed to separate the effects at the metal/organic interface from the degradation of the active layer or the hole extraction interface. To do this, Ca/Al electrodes were deposited to complete half of a substrate's devices, and samples were left both under constant illumination and 10% illumination (10% duty cycle of 1 sun illumination) in a glovebox environment. After more than ...
Wave energy device teams have identified three varieties of air turbine as potentially applicable to wave energy devices. These are: conventional axial turbines; Wells, or self-rectifying, axial turbines and Francis turbines. This report examines the constructional requirements of these devices with regard to mechanical, environmental and manufacturing considerations. It is concluded that the major benefit of optimum material selection will be reduced manufacturing costs rather than enhanced turbine performance. A methodology of material selection has been established and candidate materials have been listed for the major components of each turbine type. Comparative costs for alternative materials are included, from which significant, potential economies have been identified. Recommendations are made aimed at achieving optimum material usage in the proposed turbines.
Here we describe the fabrication, optimization, and application of a microfluidic device that integrates microdialysis (MD) sampling, microchip electrophoresis (ME), and electrochemical detection...Full Text Available
Pd/n-Si and Pd/n-GaAs devices have been irradiated from high energy ({approx}100 MeV) heavy ions of Au{sup 7+} (gold) and Si{sup 7+} (silicon) to study the irradiation effects in these junction devices on semiconductor substrates. The devices have been characterized from I-V and C-V studies for electronic flow characterization. It has been found that the devices become high resistive on the irradiation and the substrates change the conductivity type from n- to p- on the irradiation of fluence of {approx}10{sup 12}-10{sup 13} ions/cm{sup 2}. The change in conductivity type has been understood as a result of creation of deep acceptors on the irradiation.
The methods of superconducting device fabrication by lithography and multilevel processing usually require a number of processing steps with lithographic resolution and alignment adequate for the scale of the device be fabricated. As an alternative, the focused ion beam (FIB) microscope is increasingly being used directly to fabricate devices. A major advantage of using a FIB compared to other lithography methods is its flexibility and high resolution. It allows in-situ, milling (#propor to#5 nm at a beam current of 1 pA) to a variety of depths, and imaging (2 nm) of the sample. In this paper we describe our development of junction fabrication techniques using the FIB and their application in creating a range of potential sensor devices and quantum electronics applications. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
... Thus. thi, characteristic further buggeots, other things unchanging, that the more *multifunction" the ccna ;Ituent devices ari., t~he more efficienit the ...
A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this ...
With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...
A device is described for transporting loads, especially for moving belt driving stations in open pit mining operations with a propelling mechanism which for lifting a respective load is operable to move into a free space formed by the load with the ground. The device comprises a plurality of lifting mechanisms, by means of which, a lifting platform can be brought into engagement with a supporting surface of the load. The device comprises at least one supporting member which is so designed that it prevents the lifting platform from lifting off lifting mechanisms. Furthermore, means are provided which permit a turning of the lifting platform relative to the lifting mechanisms about a vertical axis which is arranged in a certain relationship to the propelling mechanism.
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
An assessment is made of the biological effects and physical hazards of static and time-varying fields associated with the NMR devices that are being used for clinical imaging and in vivo spectroscopy. A summary is given of the current state of knowledge concerning the mechanisms of interaction and the bioeffects of these fields. Additional topics that are discussed include: (1) physical effects on pacemakers and metallic implants such as aneurysm clips, (2) human health studies related to the effects of exposure to nonionizing electromagnetic radiation, and (3) extant guidelines for limiting exposure of patients and medical personnel to the fields produced by NMR devices. On the basis of information available at the present time, it is concluded that the fields associated with the current generation of NMR devices do not pose a significant health risk in themselves. However, rigorous guidelines must be followed to avoid ...
... with the ability to capture imagery in raw 24-bit format, combined with large memory storage devices enable high resolution imagery to be captured ...
This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.
Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)
Single-crystalline nanostructures often exhibit gradients of surface (and/or interface) curvature that emerge from fabrication and growth processes or from thermal fluctuations. Thus, the system-inherent capillary force can initiate morphological transformations during further processing steps or during operation at elevated temperature. Therefore and because of the ongoing miniaturization of functional structures which causes a general rise in surface-to-volume ratios, solid-state capillary phenomena will become increasingly important: On the one hand diffusion-mediated capillary processes can be of practical use in view of non-conventional nanostructure fabrication methods based on self-organization mechanisms, on the other hand they can destroy the integrity of nanostructures which can go along with the failure of functionality. Additionally, capillarity-induced shape transformations are effected and can thereby be controlled by applied fields and forces (guided or driven ...
Silicon is an attractive alloy-type anode material because of its highest known capacity (4200 mAh/g). However, lithium insertion into and extraction from silicon are accompanied by a huge volume change, up to 300%, which induces a strong strain on silicon and causes pulverization and rapid capacity fading due to the loss of the electrical contact between part of silicon and current collector. Si nanostructures such as nanowires, which are chemically and electrically bonded to the current collector, can overcome the pulverization problem, however, the heavy metal current collectors in these systems are larger in weight than Si active material. Herein we report a novel anode structure free of heavy metal current collectors by integrating a flexible, conductive carbon nanotube (CNT) network into a Si anode. The composite film is free-standing and has a structure similar to the steel bar reinforced concrete, where the infiltrated CNT network functions as both ...
Photoinduced charge separation reactions form the basis for energy storage processes in both natural and artificial photosynthesis. Moreover, rapid reversible photoinduced electron transfer reactions are a class of photophysical phenomena that can be exploited to develop schemes for optical switching. Examples from each of these fields are discussed.
We solve an R -linear problem for a multiple-connected circular domain in a class of doubly periodic functions in analytic form by a method of functional equations. This problem models transport properties of two-dimensional composite materials made from a collection of disks embedded in an otherwise uniform host.
We solve an R -linear problem for a multiple-connected circular domain in a class of doubly periodic functions in analytic form by a method of functional equations. This problem models transport properties of two-dimensional composite materials made from a collection of disks embedded in an otherwise uniform host.
Design considerations of a combined photovoltaic-thermal (PV-T) system for a particular site and application must include thermal and electrical tradeoffs. A simplified technique for determining preliminary design and economic analyses would minimize costly computer simulation and indicate feasibility. To that end, nomographs that size an array to meet a specific annual load and determine the subsequent cost savings have been developed, and are presented in this paper.
Reaction kinetics for the displacement of 5-aminoquinoline (5-Aq) and diethyl sulfide (SEt{sub 2}) from cis-[PtPh{sub 2}(CO)(L)] (L = 5-Aq or SEt{sub 2}) by aliphatic amines was measured for a wide array of amines. Reaction products were characterized by IR and NMR spectroscopies and crystalk structures of selected products were reported. Steric effects on the substitutions were discussed.
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing excitation/detection strategies which provide ...
To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).
The solar array wings were deployed by swinging two half-blanket boxes open from a folded hinge launch position .... pure-water by-product of the shuttle's fuel cell power generators because ..... outgassing limits, flammability limits, ... Foale fills a water microbiology bag for in-flight analysis. ...
The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.
The effects of upwind turbine wakes on the performance of a FloWind 17-m vertical-axis wind turbine (VAWT) were investigated through a series of field experiments conducted at the FloWind wind farm on Cameron Ridge, Tehachapi, California. From the field m...
A critical element of a retinal prosthesis is the stimulating electrode array, which is placed in close proximity to the retina. It is via this retinal-electrode interface that a retinal prosthesis electrically stimulates nerve cells to produce the perception of light. The impedance load seen by the current driver consists of the tissue resistance and the complex electrode impedance. The results in this paper show that the tissue resistance of the retina is significantly greater than that of the vitreous humor in the eye. Circuit models of the electrode-retina interface are used to parameterize the different contributors to the overall impedance.
Rapid detection and characterization of food borne pathogens such as Escherichia coli O157:H7 is crucial for epidemiological investigations and food safety surveillance. As an alternative to conventional technologies, we examined the sensitivity and specificity of nucleic acid microarrays for detecting and genotyping E. coli O157:H7. The array was composed of oligonucleotide probes (25-30 mer) complementary to four virulence loci (intimin, Shiga-like toxins I and II, and hemolysin A). Target DNA was amplified from whole cells or from purified DNA via single or multiplexed polymerase chain reaction (PCR), and PCR products were hybridized to the array without further modification or purification. The array was 32-fold more sensitive than gel electrophoresis and capable of detecting amplification products from < 1 cell equivalent of genomic DNA (1 fg). Immunomagnetic capture, PCR and a microarray were subsequently used ...
We apply two variations of the principle of Minimum Cross Entropy (the Kullback information measure) to fit parameterized probability density models to observed data densities. For an array beamforming problem with P incident narrowband point sources, N > P sensors, and colored noise, both approaches yield eigenvector fitting methods similar to that of the MUSIC algorithm[1]. Furthermore, the corresponding cross-entropies are related to the MDL model order selection criterion[2].
A multiple comparison approach using whole genome transcriptional arrays was used to identify genes and pathways involved in calorie restriction/dietary restriction (DR) life span extension in Drosophila....Full Text Available
A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in [Proc. SPIE 7077-7, (2007), Opt. Eng. 47(7), 073602-1-5 (2008)]is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high-confidence of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two dimensional BPR arrays ...
The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...
The method of treatment of uteral cancer by the brake irradiation of 25 MeV betatrone using original devices which promote forming therapeutic figured bunches is presented. The binding of the protective blocks with a special adjusting frame within the aperture of the diaphragm provided for low relative entering dose which is the advantage of high energy irradiation bunch. The use of the forming devices makes it possible to practice individual treatment and decrease the levels of irradiation doses for intact organs and tissues.
The author recounts his experiences with insertion devices at the Stanford Synchrotron Radiation Laboratory. His first experiences with wigglers occured at the Cambridge Electron Accelerator, and was carried over to SSRL with the proposal for a six pole electromagnetic wiggler. Most modern undulators, and many wigglers are now designed around permanent magnets, and the origin of this transition at SSRL was rather fortuitous and humorous. It reflects some of the personality characteristics of Klaus Halbach.
We demonstrate a two-dimensional device simulator for MOSFET structures that incorporates models for defect distributions and show predicted effects on device switching performance for various spatial distributions of defects in amorphous and polycrystalline silicon.
Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A ...
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.
The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.
A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.
The NREL Sensitized Solar Cell (SSC) Core Program supports the Solar America Initiative by: (1) targeting new devices and processes for commercialization by 2015 that are less expensive, more efficient, highly reliable, and environmentally benign; (2) collaborating with DOE OS/BES to conduct basic research targeting breakthroughs in key areas, such as ultra-high efficiency and/or ultra-low cost materials and devices.
We study the uniqueness of solutions of a semilinear elliptic problem obtained from an inverse formulation when the nonlinear terms of the equation are prescribed in a general class of real functions. The inverse problem arises in the modeling of the magnetic confinement of a plasma in a Stellarator device. The uniqueness proof relies on an L"#infinity# -estimate on the solution of an auxiliary nonlocal problem formulated in terms of the relative rearrangement of a datum with respect to the solution.
An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.
Biased above threshold (VT), pulsed photocurrent (u) measurements on windowed silicon Pd gate MOS capacitors are shifted (DV) negatively by H2/N2, whereas Au gates shift positively under NO2/air. Below VT, the shifts are reversed by adjustments of interface state population. Minor temperature increases may coax the device from inversion to depletion, inducing sign reversal of the chemical response.
Heterodyne detection with a point-contact Josephson junction has been investigated both experimentally and theoretically. The measured performance of the device at 36 GHz is in good agreement with the theory. By operating vanadium point contacts at 1.4 K, the authors have achieved a single-sideband (SSB) mixer noise temperature of 54 K with a conversion gain of 1.35 and a signal bandwidth on the order of 1 GHz. A potentially impressive performance for these devices at submillimeter wavelengths can be extrapolated from the results.
In response to severe maintenance problems caused by the highly corrosive toxic and radioactive substance used in the nuclear reprocessing industry, AEA Technology (formerly the United Kingdom Atomic Energy Authority) has developed a series of power fluidics devices with no moving parts. These maintenance-free devices are described in this article which also explores applications in fields outside their original brief. (UK).
ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.
The results show that the SQUID device eddy current testing system is a suitable tool for NDE. Due to the high low-frequency sensitivity of the SQUID sensor, the SQUID device eddy current testing system permits lower examination frequencies than the conventional eddy current probe system. The SQUID system enhances fault detection in even deeper materials layers. (orig./MM).
First Solar made 9 CdTe PV devices; found two front- and one back-side structures that show improved Jsc and Voc, respectively, compared to base device structure; best cell efficiency was 14.13%.
An electrical circuit testing device is provided, comprising a case, a digital voltage level testing circuit with a display means, a switch to initiate measurement using the device, a non-shorting switching means for selecting pre-determined electrical wiring configurations to be tested in an outlet, a terminal block, a five-pole electrical plug mounted on the case surface and a set of adapters that can be used for various multiple-pronged electrical outlet configurations for voltages from 100 600 VAC from 50 100 Hz.
The device is made by a tool at the end of a flexible cable, a motor for the rotation of the flexible, a linear drive with a guide for it between the winder and the tube.
Digital optical processing (DOP) was conceived to encompass the advantages of both electronic and optical processors, which are parallelism, flexibility, and high accuracy. The authors discuss the concept of parallelism, how it applies to DOP differently than to electronic parallel processing, and other potential advantages in using DOP. A PLZT memory device is described which can perform a series of logic or memory operations. From several of these PLZT devices a DOP is constructed to illustrate some of its programmability features.
A device for marking and searching for information on a magnetic carrier is described. In order to increase the noise immunity and reliability of the data recording and reading paths, the recording head is included between the amplifier of the clock pulses for the master oscillator and through the amplifier of the code pulses for the logical element unit. The reproduction head is connected through the code pulse shaper-amplifier with a switch which is connected with the display unit, and through another analogous clock pulse amplifier with a multivibrator.
A device for laying cut peat in drying formations is proposed consisting of separate compartments, reinforced on a common frame and with mechanisms for both vertical and horizontal mixing. In order to intensify the drying process, within the scope of laying cut peat, uniform clearances and spacing in formations is applied. The mixing compartments are joined in sections with capabilities for separate mixing in each unit. The compartments are joined together by hinges and can be turned 180 degrees on the hinges horizontal to the plane.
The purpose of this research was to investigate the de-entrainment of boron for evaporators used in nuclear power plants. The forced circulation and semi-continuous type evaporator was used in the experiment. Cyclone and glass-wool packed column which is supposed to provide good decontamination factor as well as easy maintenance, were selected as de-entrainment device to be used in the evaporation of radioactive liquid wastes. The de-entrainment device combined with cyclone and glass-wool column has shown overall DF more than 1000 for boron.
We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.
The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).
Purpose: To ensure continuous operation for condensate desalters with the control device for desalter group in a nuclear power plant by automatically averaging the operation interval between each of the desalters. Constitution: Electroconduction meters are provided at the inlet and the outlet for each of the desalters. The conduction rates at the inlet and outlet are compared to determine the re-generation timing of the condensate desalter. Limiting set value for each of the equipments in the cleanup systems is changed by using a mathematical operation circuit to average the operation interval between each of the desalters. (Ikeda, J.).
A continuous-flow filter/concentrator for separating and/or concentrating particles in a fluid is disclosed. The filter is a three-port device an inlet port, an filter port and a concentrate port. The filter separates particles into two streams by the ratio of their dielectrophoretic mobility to their electrokinetic, advective, or diffusive mobility if the dominant transport mechanism is electrokinesis, advection, or diffusion, respectively.Also disclosed is a device for separating and/or concentrating particles by dielectrophoretic trapping of the particles.
The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).
A string sieve is proposed which includes a frame, a sifting surface made of string, a device for attaching the strings made in the form of rollers installed in staggered order and a tensing device attached to traverses. To improve the effectiveness of sifting by self cleaning of the sifting surface during operation, the rollers are installed on the traverses by means of a unit of hinges, whose elastic elements are made with varying rigidity.
Three instruments for measuring local velocities in liquid-metal MHD experiments for fusion blanket applications are being evaluated. The devices are used in room-temperature NaK experiments to measure three-dimensional flow field patterns anticipated in complex blanket geometries. Hot film anemometry, a standard technique in ordinary fluids, is being used, as well as two developmental devices. One is called the Liquid Metal Electromagnetic Velocity Instrument (LEVI), and performs essentially as a local dc electromagnetic flow meter. The third device, a Thermal Transient Anemometer (TTA) is a rugged, yet relatively simple device, which measures local velocity through the mechanism of convective heat transfer, in some ways similar to hot-film anemometry. Results are presented showing the kinds of data collected this far with each instrument. Measurements include both local velocity measurements and some ...
Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the radiation spectrum for short, high-field ...
A non-synthetic polymer material, polyterpenol, was fabricated using a dry polymerization process namely RF plasma polymerization from an environmentally friendly monomer and its surface, optical and electrical properties investigated. Polyterpenol films were found to be transparent over the visible wavelength range, with a smooth surface with an average roughness of less than 0.4 nm and hardness of 0.4 GPa. The dielectric constant of 3.4 for polyterpenol was higher than that of the conventional polymer materials used in the organic electronic devices. The non-synthetic polymer material was then implemented as a surface modification of the gate insulator in field effect transistor (OFET) and the properties of the device were examined. In comparison to the similar device without the polymer insulating layer, the polyterpenol based OFET device showed significant improvements. The addition of the ...
The purpose of the Microelectronic Evaluation Laboratory at Sandia is to develop a program for evaluating CMOS LSI (complementary metal oxide silicon - large scale integrated) technology devices which are being used for the first time in a weapon system. These evaluations are based on accelerated aging studies and electrical tests to determine the reliability and life of the devices. In accelerated aging, specific, controlled stresses are applied to the device to accelerate time-to-failure. Data are used tin mathematical models to estimate life in acutal use. The stresses used for this technology are temperature and voltage. The devices are stored at temperatures with or without voltage applied (steady-state or cyclical) and periodically tested until at least 50% failures are encountered. Since most current technologies use epoxy-die-attachment, aging temperatures must be under 200/sup 0/C. This delays ...
The adhesion of a Mg:Ag cathode to the tris-(8-hydroxyquinoline) aluminum (Alq{sub 3}) in organic light emitting devices (OLEDs) can be greatly enhanced by a remote plasma treatment of the Alq{sub 3} layer using either air or N{sub 2} prior to metal deposition. The altered surface properties which lead to increased sticking coefficients of Mg and Ag, as well as enhanced adhesion, are attributed to the introduction of new functional groups into the organic layer, as observed by X-ray photoelectron spectroscopy (XPS). The storage life of the plasma treated devices in air without any capping treatment, as judged by a visible deterioration of the cathode, was increased by approximately five to six times compared to untreated OLEDs. Current-voltage characteristics and EL efficiency, however, were shown to deteriorate for devices incorporating either an air or an N{sub 2} plasma treated Alq{sub 3} layer. For OLEDs subjected to ...
This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential ...
A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves based on signal-to-noise studies using ...
A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves based on signal-to-noise studies using ...
This paper describes a technique for implementing the ultrasonic inside diameter (ID) creeping wave technique for detection and sizing ID connected defects using a phased array ultrasonic system. The technique uses multiple focal laws to produce the examination modes. The first focal law is designed to create a shear wave nominally at the critical angle for mode conversion to a longitudinal wave at the ID of a part, thus creating a creeping wave. This focal law is focused at the ID to improve sensitivity. The rest of the laws are designed to create tandem sound paths that progress up a vertical surface directly above the focal point of the creeping wave generation point. When a defect on the inner surface is detected with the creeping wave, the height of the defect can be measured from the response of a set of tandem laws without readjusting the position of the probe. Results from standard one-inch long notches of varying depths are presented.
The objective of this contract is to design and build a small, lightweight, stand-alone thermophotovoltaic electric generator, capable of at least 100 Watts useful output for charging 24V batteries. The prototype generator built consists of a pre-mixed burner, a cylindrical selective emitter mantle surrounded by six silicon photovoltaic concentrator arrays. The arrays are cooled with forced-air heat exchangers using self-powered fans. The generator, operated at 117,00 W (40,000 BTU/hr) of fuel input rate, produces 122 W of electrical power at 1.0% of efficiency. The cooling and pre-mix fans consume 35 W of electrical power resulting in a net 85 Watts of electrical output for charging batteries. The generator`s output is capable of continuous charging five 12/24V batteries over 10 hours with a 9.07 Kg (20 lbs.) of propane gas.
Grid connected photovoltaic systems is one of the most promising applications of photovoltaic systems. These systems are employed in applications where utility service is already available. In this case, there is no need for battery storage because grid power may be used to supplement photovoltaic systems (PV) when the load exceeds available PV generation. The load receives electricity from both the photovoltaic array and the utility grid. In this system, the load is the total electrical energy consumption. The main objective of the present work is to optimize the electrical load pattern in Kuwait using grid connected PV systems. In this situation, the electric load demand can be satisfied from both the photovoltaic array and the utility grid. The performance of grid connected photovoltaic systems in the Kuwait climate has been evaluated. It was found that the peak load matches the maximum incident solar radiation in Kuwait, which would ...
The presence of natural fractures in reservoir rock can significantly enhance gas production, especially in tight gas formations. Any general knowledge of the existence, location, orientation, spatial density, and connectivity of natural fractures, as well as general reservoir structure, that can be obtained prior to active seismic acquisition and drilling can be exploited to identify key areas for subsequent higher resolution active seismic imaging. Current practices for estimating fracture properties before the acquisition of surface seismic data are usually based on the assumed geology and tectonics of the region, and empirical or fracture mechanics-based relationships between stratigraphic curvature and fracturing. The objective of this research is to investigate the potential of multicomponent surface sensor arrays, and passive seismic sources in the form of local earthquakes to identify and characterize potential fractured gas reservoirs located near ...
Certain postulated faults during refuelling of AGRs may give rise to compacted fuel and graphite sleeve debris. This debris must be maintained below some safe limiting temperature. As part of a programme to assess the benefits of natural convection in cooling such debris in a region experiencing no forced cooling, a simple geometry incorporating typical debris has been studied both experimentally and by prediction. The experiment comprised an array of electrically heated fuel rods mounted co-axially in a closed cylindrical vessel and surrounded by fragments of graphite. The vessel was cooled on its cylindrical surface, the ends being insulated. Rods and vessel wall were thermocoupled. Tests covered a range of temperature and pressures in both CO_2 and N_2. Significant natural convection heat removal was demonstrated, particularly at high pressure. Predictions utilising the PHOENICS code agreed well with measured temperatures over a wide range of test conditions. ...
This work concerns the study of the nuclear superdeformation phenomenon in the rare earth region (A {approx} 150). The superdeformed (SD) states in Gadolinium and Dysprosium isotopes were produced via heavy-ion induced reactions and studied with the (EUROGAM EUROpean GAmma-ray Microscope) gamma multidetector array. Precise level attenuation method (DSAM). From the derived quadrupole moments, we find large differences in deformation between the yrast bands in neighbour nuclei explained in terms of the case of nuclei corresponding to an axis ratio of 2:1, the shell gaps are not fixed at a specific particle number and deformation. Furthermore the present results indicate that the deformations associated with identical bands are different supporting the picture that mass and deformation changes tend to compensate in SB bands with the same moments of inertia. (author). 114 refs.
The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets include the core of ...
Stripping Voltammetry (SV) at microelectrodes has gained increased interest in the analysis of aqueous solutions due to its ability to analyze low concentrations (ppb) of electroactive metallic species in solution. Existing integrated circuit (IC) technology allows the inexpensive fabrication of microelectrodes with dimensions on the order of microns and with a high degree of uniformity and reproducibility. Additional circuitry, both multiplexing and signal conditioning, can be placed directly onto the sensor offering increased sensitivity and flexibility. Multi-element electrochemical sensors containing arrays of Pt, Au, and Ag electrodes and capable of individual measurement through built-in multiplexing or simultaneous measurement at the appropriate potential ranges for each individual electrode were fabricated using existing 2 micron IC technology. Results of simultaneous measurements of low concentrations of Cd, Pb, Cu, As, and Hg in solution indicate that ...
RNA interference has become a powerful biological tool over the last decade. In this study, a tetracycline-inducible shRNA vector system was designed for silencing CFP expression and delivered alongside the yfp marker gene into Chinese hamster ovary cells using impalefection on spatially indexed vertically aligned carbon nanofiber arrays (VACNFs). The VACNF architecture provided simultaneous delivery of multiple genes, subsequent adherence and proliferation of interfaced cells, and repeated monitoring of single cells over time. Following impalefection and tetracycline induction, 53.1% 10.4% of impalefected cells were fully silenced by the inducible CFP-silencing shRNA vector. Additionally, efficient CFP-silencing was observed in single cells among a population of cells that remained CFP-expressing. This effective transient expression system enables rapid analysis of gene silencing effects using RNAi in single cells and cell populations.
The present volume on energy and the environment discusses space power requirements, space power systems, space power systems hardware, space radioisotope systems, space solar arrays, space solar cells, space station power, and terrestrial applications of aerospace technology. Attention is given to NASA future space power requirements and issues, the design of a battery charger for the NASA EOS Space Platform, in situ carbon dioxide fixation on Mars, and a preliminary design update of the CRAF/Cassini Power Subsystem. Topics addressed include concentrator testing using projected images, solar power satellites and demonstraton platforms from nonterrestrial materials, a mass sensitivity analysis of lunar orbiting beam power systems, and a power-beaming-based infrastructure for space power. Also discussed are fiber-optic sensors for aerospace electrical measurements, the preliminary design of a mobile lunar power supply, advanced power systems for EOS, and Air Force ...
Detection of fatigue damage cracks in aircraft skin structures is an ongoing NDT challenge. Cracks growing rate is difficult to predict, and for this reason, it is important to detect them as soon as possible to avoid a catastrophic break. Eddy current methods are known and well-accepted techniques which are relatively simple to carry out. However, with conventional inspection of airframe structures using standard driver-pickup eddy current probes, it is difficult to detect small fatigue cracks initiated in the second layer of the skin and in the shadow region at fastener holes. Such difficulty is related to fasteners length and their spacing which reduces test sensitivity. This report explains the development of improved eddy current probe/technique to detect and visualize fatigue cracks in fasteners. In this study, an eddy current array probe was evaluated and new coil design was suggested. Several tests were conducted on an A-300 circumferential joint sample ...
Development of a high performance air heater through use of an evacuated tube cover design is described. The cover design utilizes evacuated fluorescent light tubes laid parallel in a close packed array to form an inner transparent glazing over a conventional metal absorber plate with flow behind the plate. A tempered flat glass plate was used as an outer glazing. Both clear and infrared reflective (IR) tubes were investigated. Solar transmittance tests indicate that the clear tube array has a higher transmittance than two flat sheets of low-iron glass. The IR coating produced substantial transmittance loss. Thermal conductance tests indicate that the tubes behave similar to two flat glass sheets with a vacuum in between. The IR reflective coating was only marginally effective at reducing heat conductance. Final prototype designs are presented along with collector performance estimates.
Forty synthetic food colors were determined in drinks and candies by reversed-phase high-performance liquid chromatography with photodiode array detection. The following food colors were analyzed within 19min using a short analytical column (50mmx4.6mm i.d., 1.8mm) at 50degreeC with gradient elution: Ponceau 6R, Tartrazine, Fast yellow AB, Amaranth, Indigotine, Naphthol yellow S, Chrysoine, Ponceau 4R, Sunset yellow FCF, Red 10B, Orange G, Acid violet 7, Brilliant black PN, Allura red AC, Yellow 2G, Red 2G, Uranine, Fast red E, Green S, Ponceau 2R, Azorubine, Orange I, Quinoline yellow, Martius yellow, Ponceau SX, Ponceau 3R, Fast green FCF, Eosine, Brilliant blue FCF, Orange II, Orange RN, Acid blue 1, Erythrosine, Amido black 10B, Acid red 52, Patent blue V, Acid green 9, Phloxine B, Ben...
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of ...
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for ...
The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. The effects of ...
We report the results of mapping observations of the bipolar nebula with SiO maser emission, IRAS 19312+1950, in the CO (J=1-0 and J=2-1), 13CO (J=1-0 and J=2-1), C18O (J=1-0), CS (J=2-1), SO (J_K=3_2-2_1) and HCO+ (J=3-2) lines with the Berkeley-Illinois-Maryland Association array. Evolutional status of this source has been evoking a controversy since its discovery, though SiO maser sources are usually identified as late-type stars with active mass loss. In line profiles, two kinematical components are found as reported in previous single-dish observations: a broad pedestal component and a narrow component. Spatio-kinetic properties of a broad component region traced by 12CO lines are roughly explained by a simple spherical outflow model with a typical expanding velocity of an AGB star, though some properties of the broad component region still conflict with properties of a typical AGB spherical outflow. A narrow component region apparently exhibits a bipolar ...
This disclosure provides a solar rechargeable aircraft that is inexpensive to produce, is steerable, and can remain airborne almost indefinitely. The preferred aircraft is a span-loaded flying wing, having no fuselage or rudder. Travelling at relatively slow speeds, and having a two-hundred foot wingspan that mounts photovoltaic cells on most all of the wing`s top surface, the aircraft uses only differential thrust of its eight propellers to turn. Each of five sections of the wing has one or more engines and photovoltaic arrays, and produces its own lift independent of the other sections, to avoid loading them. Five two-sided photovoltaic arrays, in all, are mounted on the wing, and receive photovoltaic energy both incident on top of the wing, and which is incident also from below, through a bottom, transparent surface. The aircraft is capable of a top speed of about ninety miles per hour, which enables the aircraft to attain and can ...
As one of the evolutionary oldest parts of the brain, the diencephalon evolved to harmonize changing environmental conditions with the internal state for survival of the individual and the species. The pioneering work of physiologists and psychologists around the middle of the last century clearly demonstrated that the hypothalamus is crucial for the display of motivated behaviors, culminating in the discovery of electrical self-stimulation behavior and providing the first neurological hint accounting for the concepts of reinforcement and reward. Here we review recent progress in understanding the role of the lateral hypothalamic area in the control of ingestive behavior and the regulation of energy balance. With its vast array of interoceptive and exteroceptive afferent inputs and its equ...
An anisotropic power spectrum will have a clear signature in the 21cm radiation from high- redshift hydrogen. We calculate the expected power spectrum of the intensity fluctuations in neutral hydrogen from before the epoch of reionization, and predict the accuracy to which future experiments could constrain a quadrupole anisotropy in the power spectrum. We find that the Square Kilometer Array will have marginal detection abilities for this signal at z~17 if the process of reionization has not yet started; reionization could enhance the detectability substantially. Pushing to higher redshifts and higher sensitivity will allow highly precise (percent level) measurements of anisotropy.
The dependence of the mobility of DNA molecules through an hexagonal array of micropillars on their length and the applied electric field was investigated and it was found that mobility is a nonmonotonic function of their length. Results also revealed that the size dependence of the DNA mobility depends on the applied electric field and there is a crossover around E 25 V/cm for the mobility of l-DNA and T4-DNA. These observations are explained in terms of the diffusion process inside the structure affected by the solvent and are modeled using the Langevin and its corresponding Fokker-Planck equations. The phenomenon is generalized under three regimes in a phase diagram relating the electric field and the DNA lengths. The model and the associated phase diagram described here provide an expl...
This report details an investigation into the efficacy of two approaches to solving the radiation diffusion equation within a radiation hydrodynamic simulation. Because leading-edge scientific computing platforms have evolved from large single-node vector processors to parallel aggregates containing tens to thousands of individual CPU's, the ability of an algorithm to maintain high compute efficiency when distributed over a large array of nodes is critically important. The viability of an algorithm thus hinges upon the tripartite question of numerical accuracy, total time to solution, and parallel efficiency.
We discuss the advantages which the next generation interferometer SKA (the Square Kilometer Array) will bring for Very Long Baseline Interferometry (VLBI) at centimeter wavelengths. With a sensitivity to micro-Jy level flux density, a brightness temperature limit of about 10.000 K, and an expected dynamic range in future VLBI maps of better than 1.000.000, the impact of SKA on the research of compact extragalactic radio sources and their energetic jets will be very strong. We discuss some consequences, including a possible combination of SKA with future space VLBI missions.
Wind Powering America program launched the New England Wind Forum (NEWF) in 2005 to provide a single comprehensive source of up-to-date, Web-based information on a broad array of wind energy issues pertaining to New England. The NEWF newsletter provides New England stakeholders with updates on wind energy development in the region. In addition to regional updates, Issue #5 offers an interview with Angus King, former governor of Maine and co-founder of Independence Wind.
In this project we developed photonic crystal modeling capability and fabrication technology that is scaleable to large area. An intelligent optimization code was developed to find the optimal structure for the desired spectral response. In terms of fabrication, an exhaustive survey of fabrication techniques that would meet the large area requirement was reduced to Deep X-ray Lithography (DXRL) and nano-imprint. Using DXRL, we fabricated a gold logpile photonic crystal in the <100> plane. For the nano-imprint technique, we fabricated a cubic array of gold squares. These two examples also represent two classes of metallic photonic crystal topologies, the connected network and cermet arrangement.
Visible-emitting high-power laser bars are investigated at an emission wavelength of 640 nm. AlGaInP/GaInP, single tensile-strained quantum well, separate confinement heterostructures are fabricated into one cm long laser bars using a 0.7 fill factor. The low threshold current of the diode, combined with the aggressive heatsinking of a silicon microchannel cooler has resulted in more than 12 W of continuous wave output power.
A simple closed-form equation to calculate the envelope correlation between any two receiver or transmitter antennas in a multi-input multi-output (MIMO) system of an arbitrary number of elements is derived. The equation uses the scattering parameters obtained at the antenna feed point to calculate the envelope correlation coefficient. This approach has the advantage that it does not require knowledge of the antenna radiation pattern. Numerical data that include conductor and permittivity loss are shown to validate the approach. Using the scattering parameters for calculating the envelope correlation is less laborious and relatively cheaper, as compared to the radiation pattern approach.
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
A critical element of a retinal prosthesis is the stimulating electrode array, which is placed in close proximity to the retina. It is via this retinal-electrode interface that a retinal prosthesis electrically stimulates nerve cells to produce the perception of light. The impedance load seen by the current driver consists of the tissue resistance and the complex electrode impedance. The results in this paper show that the tissue resistance of the retina is significantly greater than that of the vitreous humor in the eye. Circuit models of the electrode-retina interface are used to parameterize the different contributors to the overall impedance. PMID:17325413
The importance of ecosystem restoration to land reclamation is discussed. If a plant community is to be self sustaining, natural diversity processes provide a useful model for restoration. Biodiversity is important for utilitarian, ecological, and ethical/aesthetic reasons. Issues that must be considered include sampling and management scales, the separate richness of the diverse array of species playing a role in ecosystem productivity and stability, and natural trends in diversity. Ecological restoration comprises two fundamental activities: management for some pre-disturbance level of biodiversity and the combination of species in a manner that is essentially experimental. Endeavours to restore biological diversity are a useful method of experimenting with the factors that control ecosystem structure and function. 21 refs.
We demonstrate the possibility to fabricate arrays of pores oriented perpendicular and parallel to the top surface of the ZnSe nanotemplate. The control of material conductivity allows one to produce porous ZnSe samples with the mean pore diameter and characteristic skeleton wall thickness from several hundreds of nanometers to about 15 nm. In addition, electrochemical treatment of ZnSe single crystals using photoresist masks allows one to prepare buried porous structures with pores directed parallel to the top template surface, which is especially important for photonic applications.
Within the framework of the EU power plant conceptual study (PPCS), a modular He-cooled divertor concept with integrated pin array (HEMP) is being developed at the Forschungszentrum Karlsruhe. The design goal is to achieve a high heat flux of at least about 10-15 MW/m"2, which is proposed for a near-term reactor model like DEMO. The development and optimization of the divertor concept require a close link between the main issues: design, analyses, materials and fabrication technology, and experiments with feedbacks between them to be accounted for. Design-specific requirements on materials and fabrication issues will be discussed.
The ZnO nanorods were used as a template to fabricate nickel nanoclusters by electrodeposition. The ZnO nanorod arrays act as a nano-semiconductor electrode for depositing metallic and magnetic nickel nanoclusters. The growth sites of Ni nanoclusters could be controlled by adjusting the applied potential. Under -1.15 V the Ni nanoclusters could be grown on the tips of ZnO nanorods. On increasing the potential to be more negative the ZnO nanorods were covered by Ni nanoclusters. The magnetic properties of the electrodeposited Ni nanoclusters also evolved with the applied potentials.
Florida posseses climatic, land, and water resources favorable for abundant biomass production. Therefore, a statewide program has been initiated to determine adapted species for the available array of production sites. Plant resources under investigation include woody, aquatic, grasses, hydrocarbon, and root crop species. The goal is to produce a continuous stream of biomass for the various biofuel conversion options. Preliminary yields from energy cropping experiments range from about 10 to nearly 90 metric tons per hectare per year, depending on the crop and the production systems employed. (Refs. 15).
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
The lateral bearing device is made of 7 lateral supports, each positioned to allow the displacement of the steam generator due to thermal or seismic effects. Each support includes a buffer plate that can be positioned on the steam generator using a position control assembly. This control assembly consists of a screw jack arrangement where the nut is fastened via an energy absorbing layer to a footplate that is fixed to the concrete wall of the steam generator enclosure. 4 figs.
Individuals who use augmentative and alternative communication (AAC) depend on technology to meet their daily needs and form relationships. Speech generating devices (SGDs) are integral components of communication systems. Reliability of SGDs is critical for effective use in everyday life. This study examined the reliability of new SGDs and found that mean time to first failure was 42.7 (SD = 41.2) weeks and at least 40% required repairs within the first year of use. The components that most frequently broke down were touch screens, wiring, main boards, batteries, memory cards, and AC adaptors. The costs of repairing SGDs were analyzed. The clinical implications of device breakdown are identified for key stakeholders, including clients, families, service providers, funding agencies, and ma...
The first part of the study contains a literature compilation of more than 50 original publications reporting the radiation induced effects in 17 different high polymer materials and glass which are relevant in the manufacturing of medical devices or packing materials. The results collected demonstrate that high energy radiation, i.e. gamma- or X-rays, causes various physical and chemical alterations in high polymer materials. A detailed summary and discussion of the results of the original publications is not included in the present report, it will be presented in the second part of the study. Furthermore, the second part of the study will refer to the aspect of wholesomeness of irradiated medical devices or packing materials in a more general manner of representation. (orig.).
One of the issues with printers - or the increasingly common multi-function devices (MFDs) - is that no one takes any notice of them. They just sit there, unacknowledged and ignored, in the corner of the office, printing, photocopying, faxing and even emailing away and no one gives them a second thought. Until something goes wrong. No-one gives printers - or multi-function devices (MFDs) - a second thought, as they have just been sitting there in offices doing their thing for years. But the problem is that they have now grown up to become fully-fledged computers and are starting to present an information security risk. These machines now have operating systems, hard drives and IP addresses, and have been exploited as storage devices by hackers. But most problems stem from poor internal pra...
Photoemission-electron-microscopy (PEEM) is introduced as a tool for the characterization of organic electronic devices. PEEM-measurements are used for imaging as well as for spectroscopic analyses by illumination with light of a Hg-lamp (4.9 eV), a D2 lamp (7.3 eV), and with synchrotron radiation for resonant photoelectron spectroscopy. We determine the charge carrier concentration inside the channel region of the organic device and its lateral distribution. From resonant photoelectron spectroscopy (RPES) we deduce the electronic states which are accessible with the Hg and D2 illumination. Photoelectron-spectroscopy at selected areas ({mu}-PES) gives information on the absolute values of surface potentials in lateral resolution. We are able to perform these studies with applied voltages at the source- and drain-electrode.
The metallo-organic chemical vapor deposition (MOCVD) process has been used with great success to grow AlGaAs-GaAs and InGaAsP-InGaAs-InP heterostructure materials for electronic and optoelectronic applications. Devices fabricated from Al/sub x/Ga/sub 1-x/As-GaAs heterostructures grown by MOCVD include bipolar transistors, field-effect transistors (FETs), high-mobility (or modulation-doped) FETs, large-area high-efficiency solar cells, low-threshold lasers, high-power lasers, quantum-well lasers, and visible lasers. The state of the art for the MOCFD growth of optoelectronic devices is reviewed in this paper, and some comments are made regarding future trends in the growth of these materials by MOCVD.
A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of ...
A new class of low aspect ratio toroidal hybrid stellarators is found using a more general plasma confinement optimization criterion than quasisymmetrization. The plasma current profile and shape of the outer magnetic flux surface are used as control variables to achieve near constancy of the longitudinal invariant J{sup {asterisk}} on internal flux surfaces (quasiomnigeneity), in addition to a number of other desirable physics target properties. A range of compact (small aspect ratio A), low plasma current devices have been found with significantly improved confinement, both for thermal as well as energetic (collisionless) particle components. With reasonable increases in magnetic field and geometric size, such devices can also be scaled to confine 3.5 MeV alpha particle orbits.
A new class of low aspect ratio toroidal hybrid stellarators is found using more general plasma confinement optimization criterion than quasi-symmetrization. The plasma current profile and shape of the outer magnetic flux surface are used as control variables to achieve near constancy of the longitudinal invariant J* on internal flux surfaces (quasi-omnigeneity), in addition to a number of other desirable physics target properties. We find that a range of compact (small aspect ratio A), high {beta} (ratio of thermal energy to magnetic field energy), low plasma current devices exist which have significantly improved confinement both for thermal as well as energetic (collisionless) particle components. With reasonable increases in magnetic field and geometric size, such devices can also be scaled to confine 3.5 MeV alpha particle orbits.
Google's Android is a comprehensive software framework for mobile communication devices (i.e., smartphones, PDAs). The Android framework includes an operating system, middleware and a set of key applications. The incorporation of integrated access services to the Internet on such mobile devices, however, increases their exposure to damages inflicted by various types of malware. This paper provides a comprehensive security assessment of the Android framework and the security mechanisms incorporated into it. A methodological qualitative risk analysis that we conducted identifies the high-risk threats to the framework and any potential danger to information or to the system resulting from vulnerabilities that have been uncovered and exploited. Our review of current academic and commercial solutions in the area of smartphone security yields a list of applied and recommended defense mechanisms for hardening mobile devices in ...
Trends in front-end-of-line technology are discussed. At the chip level, many of the important parameters are published in the National Technology Roadmap for Semiconductors in 1994. At the device and circuit level, both bipolar and CMOS are scalable. However, the large standby power of bipolar circuits severely limits the integration level of bipolar chips. The inherently low standby power of CMOS, on the contrary, allows the integration level of CMOS circuits to continue increasing with scaling. In reality, both the electric field and power density of CMOS devices have been gradually rising over the generations owing to non-scaling effects of thermal voltage and silicon bandgap. As power supply voltage reaches 1.5V and below, circuit performance can only be gained at the expense of higher active or standby power of the chip. Implications of device scaling on contact and silicide technology are addressed. Trends of local ...
Purpose In literature, few papers compare different hemostatic devices in laparoscopic adrenalectomy. This sequential cohort study analyzes the outcomes of laparoscopic adrenalectomy performed by different hemostatic instruments, to evaluate if any of them has any advantage over the other and as secondary endpoints, the impact of body mass index (BMI) and tumor size on the indication, and the outcome of laparoscopic adrenalectomy. Methods Forty-six patients, aged 54.6???46?years, underwent laparoscopic adrenalectomy over 5?years. Mean BMI was 27???4.8?kg/m2. Twenty-four patients had a left tumor, and 22 had a right one. Patients were divided into two groups according to the hemostatic device: Ultracision was used in 26 patients, and Ligasure was used in 20. Groups were well matched for his...
Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.
Thermoacoustics deals with the conversion of heat energy into sound energy and vice versa. It is a new and emerging technology which has a strong potential towards the development of sustainable and renewable energy systems by utilizing waste heat or solar energy. Although simple to fabricate, the designing of thermoacoustic devices is very challenging. In the present study, a comprehensive design and optimization algorithm is developed for designing thermoacoustic devices. The unique feature of the present algorithm is its ability to design thermoacoustically-driven thermoacoustic refrigerators that can serve as sustainable refrigeration systems. In addition, new features based on the energy balance are also included to design individual thermoacoustic engines and acoustically-driven thermoacoustic refrigerators. As a case study, a thermoacoustically-driven thermoacoustic refrigerator has been designed and optimized based on the developed ...
Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).
Purpose: To flatten temperature distribution of coolant within a core. Constitution: The control device of the present invention is to vary reactivity of a fast breeder to control a reactor power. In general, the control device of this kind comprises a guide pipe arranged within the core and a control rod movable up and down within the guide pipe, and a coolant flows from bottom toward top within the guide pipe. Since a cooling flow rate has a margin, temperature of coolant outlet is extremely low as compared to a fuel assembly, and therefore temperature gradient in the vicinity of the top of the control rod becomes sharp to possibly impart thermal shock to the structural material. In the present invention, the flow passage of coolant is varied to thereby avoid outflow thereof into the core, thus flattening the temperature distribution of the coolant within the core. (Kamimura, M.).
Course website from Cambridge on ceramic materials. This site contains eight lectures in PDF format (Adobe Reader required), two question sheets, five practicals (including answers), digital movies and further useful links. "There is a strong relationship between the structure of a material and its physical properties. The properties of a material whether mechanical, electrical, optical or magnetic, determine how it can be used in practical applications. In this course, the focus is on the structure / property relationship for ionic materials with electrical properties utilised in various transducer devices. The materials considered include perovskites, which have special polarisation properties exploited in ferroelectric, pyroelectric and piezoelectric devices. Other oxides, such as zirconia, have structures permitting rapid diffusion of ions, making them suitable for use in sensors, fuel cells and batteries. The scientific principles ...
The article is aimed to design and testing of joystick with force feedback used in direct, human control of lifting device. The paper starts with the basic description of designed and tested by us MR rotary brake. Some initial laboratory investigations results of such brakes are presented. The usage of MR brakes in 2 axis joystick is proposed. Such, built by as joystick, is described. It was used as Human-Machine Interface in active control of lifting device. The designed and built 2 axis manipulator with electrohydraulic drive is described. In the paper, the based on PC with input/output card, control system of mentioned above joystick with MR brake and manipulator is described. Finally the control algorithm is proposed.
In this work, we investigated self-heating related instability in polysilicon thin film transistors (poly-Si TFTs) fabricated on polyimide (PI) substrates. Indeed, when Joule heating becomes relevant, the temperature of the active layer can substantially rise, since the devices are fabricated on thermally insulating substrates. As a result, electrical instability is triggered and attributed to the generation of interface states, due to the Si-H bond breaking, and charge trapping into the gate insulator. In addition, by using 3-dimensional numerical simulations, coupling the thermodynamic and transport models, we analyzed the temperature distribution of the device under operating conditions and found that self-heating is more severe for devices fabricated on plastic substrates.
A novel floating-gate avalanche injection (FAMOS) type erasable programmable read-only memory (EPROM) device is demonstrated, with a heavily focused ion-beam (FIB) implanted region of about 0.2-..mu..m width at the drain edge of the channel. This heavily B/sup +/-doped region permits a higher electric field near the drain edge, resulting in a remarkable increase of the hot-carrier generation rate, and reduces both the programming voltage and programming time. A three-dimensional device simulator, CADDETH, predicted that the electric field at the drain edge would increase by about six times, which would lead to hot-carrier generation efficiency three orders of magnitude higher.
The Infrared Camera (IRC) is one of the scientific focal plane instruments on board the ASTRO-F infrared astronomical satellite. The IRC is designed for wide field imaging and slit-less spectroscopic observations at near- and mid-infrared wavelengths. The IRC consists of three channels; NIR, MIR-S and MIR-L, each of which covers wavelengths of 2-5, 5-12 and 12-26 micron, respectively. All channels adopt compact refractive optical designs. Large format array detectors (a InSb 512 x 412 array and two Si:As IBC 256 x 256 arrays) are employed. Each channel has 10 x 10 arcminutes wide FOV with diffraction-limited angular resolution of 70cm aperture of the liquid helium cooled telescope at wavelengths over 5 micron. A 6-position filter wheel is placed at the aperture stop in each channel, and has three band-pass filters, two grisms/prisms and a mask for dark current measurements. The 5 sigma sensitivity of one pointed observation ...
We attempt to image the rupture propagation of the 2004 M6.0 Parkfield earthquake by analyzing records from the USGS Parkfield seismic array (UPSAR) and other strong-motion stations. The UPSAR array consists of 12 stations distributed over about one square kilometer at a distance of 10~km from the San Andreas fault near Parkfield, California. We employ a method that uses reverse time migration to stack the seismograms at back-projected locations along the fault. We use waveform cross-correlation to align the initial P-wave arrivals and correct for small static time shifts in the records. This forces a coherent image at the hypocenter at the quake origin time. Initial results at later time steps show some evidence of the expected rupture propagation to the north. However, the resolution of the back-projection is limited by the small aperture of the UPSAR array. Records from other strong-motion stations can improve the ...
A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second ...
A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second ...
This thesis develops methods for recording and analysis of seismo-acoustic interface waves for determination of shear wave velocity as a function of depth and includes this in standard refraction seismic surveying. It investigates different techniques for estimation of dispersion characteristics of the interface waves and demonstrates that multi sensor spectral estimation techniques improve the dispersion estimates. The dispersion estimate of the fundamental interface wave mode is used as input to an object function for a model based linearized inversion. The inversion scheme provides an estimate of the shear wave velocity as a function of depth. Three field surveys were performed. Data were acquired with a standard bottom deployed refraction seismic hydrophone array containing 24 or 48 receivers, with a receiver spacing of 2.5 m. Explosive charges were used as sources. The recording time was increased from 0.5 to 8 s, compared to standard refraction seismic ...
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
The waterjet technique enables precise tissue dissection without thermal damage and with preservation of vessels in general surgery. In neurosurgery, these qualities could help to avoid damage of intact brain parenchyma in tumour resections. The present study reports our first results with this technique in brain metastases. Ten patients with intracranial metastases underwent surgery with the aid of the waterjet. Resection was performed in combination with conventional neurosurgical methods. The follow-up consisted of neurological examination and MRI studies. Intraoperatively, the device was easy to handle. No complications due to the device were observed. Vessels were preserved at pressures below 20 bars. Six of the tumours consisted of soft tissue which was poorly demarcated from the surrounding brain. In these tumours, the waterjet was very helpful. It enabled tumour debulking by aspiration and - more important - precise separation of tumour ...
Isokinetic training and assessment of the knee joint has been the mainstay of rehabilitation, especially in patients with anterior cruciate ligament deficiency. Besides the original shin pad used, the...Full Text Available
The DataAccessBean is similar to the Data Access Object (DAO) interface in that the DataAccessBean interface is meant to encapsulate the implementation details of the DynamicJavaBean that accesses persistent storage devices such as RDBMS, flat text file databases, etc.
Beta silicon carbide is an excellent candidate semiconductor material for demanding applications in high power and high temperature electronic devices due to its high breakdown voltage, relatively large band gap, high thermal conductivity and high melting...
A simple device is described which is used to determine treatment distance and beam direction in electron therapy employing one collimation. A technique for the production of irregular field templates and localization films is given.
A theoretical framework centering on four classes of self-referent constructs is offered as a device for integrating the diverse areas constituting medical sociology. Guidance by this framework...Full Text Available
SummaryBackgroundThe US FDA has been collecting information on medical devices involved in significant adverse advents since 1984. These reports have...Full Text Available
An ignition device of the plasma jet type is disclosed. The device has a cylindrical cavity formed in insulating material with an electrode at one end. The other end of the cylindrical cavity is closed by a metal plate with a small orifice in the center which plate serves as a second electrode. An arc jumping between the first electrode and the orifice plate causes the formation of a highly-ionized plasma in the cavity which is ejected through the orifice into the engine cylinder area to ignite the main fuel mixture. Two improvements are disclosed to enhance the operation of the device and the length of the plasma plume. One improvement is a metal hydride ring which is inserted in the cavity next to the first electrode. During operation, the high temperature in the cavity and the highly excited nature of the plasma breaks down the metal hydride, liberating hydrogen which acts as an additional fuel to help plasma formation. ...
Jul 16, 2005 ... The purpose of this capability portfolio is to develop a roadmap for NASA to exploit .... 1.2.4-2: Some applications of nanotechnology to advanced EVA suits. ..... Power/Energy Storage: Materials and devices for energy storage and .... to 80 %), manufacturing costs (up to 50%) and enhancements in durability. ...
We have developed miniature (≈1 μm diameter) microcavity surface-plasmon-resonance sensors (MSPRS), integrated them with microfluidics and tested...Full Text Available
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
AIMS—(1) To validate a leg to leg bioimpedance analysis (BIA) device in the measurement of body composition in children by assessment of its agreement with dual energy x...Full Text Available
The tremendous heat generated in a computer chip or very large scale integrated circuit raises many challenging issues to be solved. Recently, liquid metal with a low melting point was established as the most conductive coolant for efficiently cooling the computer chip. Here, by making full use of the double merits of the liquid metal, i.e. superior heat transfer performance and electromagnetically drivable ability, we demonstrate for the first time the liquid-cooling concept for the thermal management of a computer chip using waste heat to power the thermoelectric generator (TEG) and thus the flow of the liquid metal. Such a device consumes no external net energy, which warrants it a self-supporting and completely silent liquid-cooling module. Experiments on devices driven by one or two stage TEGs indicate that a dramatic temperature drop on the simulating chip has been realized without the aid of any fans. The higher the heat load, the larger ...
The sensitive explosives used in initiating devices like primers and detonators are called primary explosives. Successful detonations of secondary explosives are accomplished by suitable sources of...Full Text Available
The authors report on the nano-fabrication of GaN/AlGaN device structures using focused ion beam (FIB) etching, illustrated on a GaN/AlGaN heterostructure field effect transistor (HFET). Pillars as small as 20nm to 300nm in diameter were fabricated from the GaN/AlGaN HFET. Micro-photoluminescence and UV micro-Raman maps were recorded from the FIB-etched pattern to assess its material quality. Photoluminescence was detected from 300nm-size GaN/AlGaN HFET pillars, i.e., from the AlGaN as well as the GaN layers in the device structure, despite the induced etch damage. Properties of the GaN and the AlGaN layers in the FIB-etched areas were mapped using UV Micro-Raman spectroscopy. Damage introduced by FIB-etching was assessed. The fabricated nanometer-size GaN/AlGaN structures were found to be of good quality. The results demonstrate the potential of FIB-etching for the nano-fabrication of III-V nitride devices.
An inner surface substrate of metal tubes is provided with a single layer of randomly distributed metal bodies bonded to the substrate, spaced from each other, and substantially surrounded by the substrate to form body void space.
Atrial septal defect closure is now routinely performed using a percutaneous approach under echocardiographic guidance. Centrally located, secundum defects are ideal for device closure but there is...Full Text Available
Methodologies are given for conducting studies to discover and map break deformations in coal strata using various modifications on radiometry, together with the field for their use. Results that were obtained using the IKS-50 device are given.
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between ...
Results are presented of analysis of the dust content of air and the resources for removing sludge at the mines of the Kuzbass during drilling of ascending shafts. A design is proposed for sludge removing devices with automatic opening and closing of the valve hinges.
A controlled bidirectional quantum secret direct communication scheme is proposed by using a Greenberger-Horne-Zeilinger (GHZ) state. In the scheme, two users can exchange their secret messages simultaneously with a set of devices under the control of a third party. The security of the scheme is analysed and confirmed.
A pneumatic device is in the form of a U-shaped frame, on which a prong is attached by using two pairs of levers. It also has a hydraulic or pneumatic cyclinder, whose rod is connected to one of the pairs of levers. All connections are hinges.
The stand is designed to test supports of development workings. To expand the test range for various types of supports, the cross pieces have fixing devices in the form of winches interacting by cables through blocks fastened to the stand body with the support hinges.
IntroductionA rare side effect of antipsychotic medication is neuroleptic malignant syndrome, mainly characterized by hyperthermia, altered mental state, haemodynamic dysregulation,...Full Text Available
BackgroundHip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly...Full Text Available
The primary method for neuronal communication involves the extracellular release of small molecules that are packaged in secretory vesicles. We have developed a platform to separate, lyse, and...Full Text Available
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available