WorldWideScience
 
 
1

Opposed jet diffusion flames of nitrogen-diluted hydrogen vs air - Axial LDA and CARS surveys; fuel/air rates at extinction  

Science.gov (United States)

An experimental study of H-air counterflow diffusion flames (CFDFs) is reported. Coaxial tubular

1989-01-01

2

Bibliography of Documents Related to the Theory, Operation ...  

Science.gov (United States)

... 28, No. 12B, December 1986, pp. 1931-1942. Dattner, A. and Eninger, J., "Studies of a Coaxial Plasma Gun," The Physics of Fluids, Vol. 7, No. ...

1990-11-01

3

Coumarin-4 laser efficiency up to 0. 14% under coaxial flash-lamp pumping  

Energy Technology Data Exchange (ETDEWEB)

Under coaxial flash lamp pumping the laser efficiency of coumarin-4 in slightly basic ethyl alcohol solution as an active medium has reached a value of 0.14%. That is three times higher than that in the basic aqueous solution. Its tunable wavelength range of laser output has extended from 440 to 510 nm with the maximum at 460 nm.

1987-02-01

4

Studies of accelerated compact toruses  

Energy Technology Data Exchange (ETDEWEB)

In an earlier publication we considered acceleration of plasma rings (Compact Torus). Several possible accelerator configurations were suggested and the possibility of focusing the accelerated rings was discussed. In this paper we consider one scheme, acceleration of a ring between coaxial electrodes by a B/sub theta/ field as in a coaxial rail-gun. If the electrodes are conical, a ring accelerated towards the apex of the cone undergoes self-similar compression (focusing) during acceleration. Because the allowable acceleration force, F/sub a/ = kappaU/sub m//R where (kappa < 1), increases as R/sup -2/, the accelerating distance for conical electrodes is considerably shortened over that required for coaxial electrodes. In either case, however, since the accelerating flux can expand as the ring moves, most of the accelerating field energy can be converted into kinetic energy of the ring leading to high efficiency.

1983-01-04

5

Extending the service life and power of a gas laser with a coaxial continuous cathode  

Energy Technology Data Exchange (ETDEWEB)

A continuous gas laser may be operated reliably with an increased pressure level and current level without significant cathode sputtering. This increases the service life and the specific power of the laser. The design eliminates the formation of arcs in operational conditions, which also has a positive influence on laser operation. The proposed laser is used successfully in modern interferometry, in geodesy and in materials analysis. The laser design is characterized by the presence of separation rings inside the coaxial cathode. The separation rings are fastened to the anode. The anode is a perforated tube that is connected to two final protective rings. Electrodes from the housing pass through the final rings. In order to increase laser power, two or more lasers of such design are used and are positioned on the same axis in a single housing.

1983-12-31

6

Electrical Transmission Line Diametrical Retention Mechanism  

Science.gov (United States)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

2006-01-03

7

Design of a far-infrared CHI wiggler free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

The preliminary design of a far-infrared free-electron laser with a Coaxial Hybrid Iron (CHI) wiggler is presented. The CHI wiggler consists of a central rod and outer ring of alternating ferrite and dielectric spacers. A periodic wiggler field is produced when the CHI structure is immersed in an axial magnetic field. The design under investigation makes use of 1A, 1MV annular electron beam interacting with the TE{sub 01} coaxial waveguide mode at approximately 1 THz ({lambda} = 300 {mu}m). The nominal wiggler period is 0.5 cm and the inner and outer waveguide radii are 0.4 and 0.8 cm, respectively. An axial guide field of 5-10 kG is used. The device performance is modeled with slow-time-scale nonlinear code. Self fields and axial velocity spread are included in the model. Theoretical results will be presented.

1995-12-31

8

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

9

Thermal conductivity coefficient of steam up to 500 deg C and 500 bar  

International Nuclear Information System (INIS)

The thermal conductivity of steam has been measured as a function of temperature from 100 deg C to 515 deg C and pressure up to 500 bar using the coaxial cylinder method. Corrections to the apparent thermal conductivity data are detailed. Correlations of the thermal conductivity coefficients are given in terms of temperature and density.

10

Plugging indicator for controlling the sodium quality. Indicateur de bouchage pour le controle de la qualite du sodium  

Energy Technology Data Exchange (ETDEWEB)

This device has and head-race pipe with an external part and a coaxial inner part. A measuring head is mounted movable between these 2 parts and has at least a thermocouple and a mobile grid for varying the section and the sodium flow to facilitate the impurities dissolution. This ensemble is completed by a longitudinal body containing the main parts of the indicator and surrounded by a thermal exchanger to cool the sodium.

1991-09-20

11

Familiar arrangement for a Ge(Li) Compton linear polarimeter  

Energy Technology Data Exchange (ETDEWEB)

A simple arrangement of standard horizontal coaxial Ge(Li) detectors with the aim of constructing a Compton linear-polarimeter was tested. High polarization sensitivity and detection efficiency were achieved. The characteristics of the polarimeter and analysis of the observed quantities in terms of the linear-polarization mixing coefficient Hsub(l)(LL') are described.

1982-05-15

12

Centering device  

Energy Technology Data Exchange (ETDEWEB)

A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.

1980-03-15

13

A familiar arrangement for a Ge(Li) Compton linear polarimeter  

International Nuclear Information System (INIS)

A simple arrangement of standard horizontal coaxial Ge(Li) detectors with the aim of constructing a Compton linear-polarimeter was tested. High polarization sensitivity and detection efficiency were achieved. The characteristics of the polarimeter and analysis of the observed quantities in terms of the linear-polarization mixing coefficient Hsub(l)(LL') are described. (orig.).

14

Study of 750 J plasma coaxial accelerator  

International Nuclear Information System (INIS)

A 750 J plasma coaxial accelerator is used to produce plasma using air at 0.2 torr pressure and 8 kv charging voltage. The discharge current and voltage traces showed that the total circuit inductance was about 1750 ?H. The experimental results showed that the plasma sheath reached the muzzle after 6 ?s with velocity equal to 4 cm/?s, after then it decreased, while the simulation model showed that the plasma sheath reaches the muzzle with velocity of 3 cm/?s and after one microsecond it increases to reach about 4 cm/?s after 12 ?s then it decreased. The plasma temperature measurements showed that the plasma sheath reached the muzzle with temperature of about 9 eV and increase to reach about 12 eV after 8.5 ?s then after it decrease. The simulation model showed that the plasma temperature at the muzzle is about 10.5 eV and continue to increase to reach 17.5 eV after 12 ?s then it decrease.

2009-05-01

15

Coaxial nanocables of p-type zinc telluride nanowires sheathed with silicon oxide: synthesis, characterization and properties  

International Nuclear Information System (INIS)

Coaxial nanocables with a single-crystalline zinc telluride (ZnTe) nanowire core and an amorphous silicon oxide (SiO_x) shell have been synthesized via a simple one-step chemical vapor deposition (CVD) method on gold-decorated silicon substrates. The single-crystal ZnTe nanowire core is in zinc-blende structure along the [111] direction, while the uniform SiO_x shell fully covers the core with no observable pin-hole or crack. Formation mechanisms of the ZnTe-SiO_x nanocables are discussed. The ZnTe nanowire core shows p-type electrical properties while the SiO_x shell acts as an effective insulating layer. The ZnTe-SiO_x nanocables may have potential applications in nanoscale devices, such as p-type FETs and nanosensors.

2009-11-11

16

Variable loading roller  

Energy Technology Data Exchange (ETDEWEB)

An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves in the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first. 14 figs.

1988-01-21

17

Variable loading roller  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves on the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first.

1989-06-27

18

Similarity between the primary and secondary air-assisted liquid jet breakup mechanism  

CERN Document Server

we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.

2007-01-01

19

Radio-frequency and microwave load comprising a carbon-bonded carbon fiber composite  

Energy Technology Data Exchange (ETDEWEB)

A billet of low-density carbon-bonded carbon fiber (CBCF) composite is machined into a desired attenuator or load element shape (usually tapering). The CBCF composite is used as a free-standing load element or, preferably, brazed to the copper, brass or aluminum components of coaxial transmission lines or microwave waveguides. A novel braze method was developed for the brazing step. The resulting attenuator and/or load devices are robust, relatively inexpensive, more easily fabricated, and have improved performance over conventional graded-coating loads.

1998-01-01

20

Fast Neutral Pressure Measurements in NSTX  

Energy Technology Data Exchange (ETDEWEB)

Several fast neutral pressure gauges have been installed on NSTX [National Spherical Torus Experiment] to measure the vessel and divertor pressure during inductive and coaxial helicity injected (CHI) plasma operations. Modified, PDX [Poloidal Divertor Experiment]-type Penning gauges have been installed on the upper and lower divertors. Neutral pressure measurements during plasma operations from these and from two shielded fast Micro ion gauges at different toroidal locations on the vessel mid-plane are described. A new unshielded ion gauge, referred to as the In-vessel Neutral Pressure (INP) gauge is under development.

2002-08-06

 
 
 
 
21

The giant linear magnetostriction in elastic ferromagnetic composites within a porous matrix  

Energy Technology Data Exchange (ETDEWEB)

In this article, a method of producing elastic ferromagnetic composite containing particles of chemical pure iron with sizes of 0.10-0.15 mm was described. The particles were dispersed in an elastic matrix of an elastic silicone rubber. The filling factor of composite by ferromagnetic particles and porous factors were changed in the range from 0.15 to 0.45. The samples of the obtained composite were placed in the magnetic field with induction of 0-8 T, produced by the Bitter-type magnet. The longitudinal magnetostriction of samples was measured by using a coaxial capacitor with a movable plate. It was found that the maximal relative elongation of samples was 4.81% and hysteresis of magnetostriction and also remanent magnetostriction amounted to 1.08%. A slow decay of remanent magnetostriction up to 0.14% in 10{sup 5} s was also observed.

2006-06-15

22

The Xygra gun simulation tool.  

Energy Technology Data Exchange (ETDEWEB)

Inductive electromagnetic launchers, or coilguns, use discrete solenoidal coils to accelerate a coaxial conductive armature. To date, Sandia has been using an internally developed code, SLINGSHOT, as a point-mass lumped circuit element simulation tool for modeling coilgun behavior for design and verification purposes. This code has shortcomings in terms of accurately modeling gun performance under stressful electromagnetic propulsion environments. To correct for these limitations, it was decided to attempt to closely couple two Sandia simulation codes, Xyce and ALEGRA, to develop a more rigorous simulation capability for demanding launch applications. This report summarizes the modifications made to each respective code and the path forward to completing interfacing between them.

2008-12-01

23

Studies of basic parameters of electron-counting detection  

International Nuclear Information System (INIS)

Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).

1990-05-21

24

Structures in the Universe and Origin of Galaxies  

CERN Document Server

The analysis of images (of obtained in various ranges of the lengths of waves) of luminous objects in the Universe by means of a method of multilevel dynamic contrasting led author to the conclusions: a) the structures of all observable galaxies represents a complicated constructions which have the tendency to self-similarity and made of separate (basic) blocks, which are a coaxially tubular structures and a cartwheel-like structures; b) the majority of observable objects in the Universe are luminous butt-ends of almost invisible (of almost completely transparent) of filamentary formations which structures are seen only near to their luminous butt-ends; c) the result of analysis of images of cosmic objects show the structure of many pairs of cooperating galaxies point to opportunity of their formation at butt-ends generated in a place of break of the similar filament; d) the interacting galaxies (M 81 and M 82) show they are butt-ends of sawed off of two branches ...

2005-01-01

25

Spatial distribution of IGC-30 Ge-detector's efficiency  

International Nuclear Information System (INIS)

The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).

1993-12-02

26

Solar energy modulator  

Energy Technology Data Exchange (ETDEWEB)

A module is described with a receiver having a solar energy acceptance opening and supported by a mounting ring along the optic axis of a parabolic mirror in coaxial alignment for receiving solar energy from the mirror, and a solar flux modulator plate for varying the quantity of solar energy flux received by the acceptance opening of the module. The modulator plate is characterized by an annular, plate-like body, the internal diameter of which is equal to or slightly greater than the diameter of the solar energy acceptance opening of the receiver. Slave cylinders are connected to the modulator plate for supporting the plate for axial displacement along the axis of the mirror thereby shading the opening with respect to solar energy flux reflected from the surface of the mirror to the solar energy acceptance opening.

1981-07-01

27

Modeling and optimization of a propeller-type tribocharger for granular materials  

British Library Electronic Table of Contents (United Kingdom)

Electrostatic separation has already proved to be an effective means for the recycling of granular plastics from industrial wastes. The aim of the present work was to optimize the operation of a novel device that could ensure effective triboelectric charging of such materials prior to their selective sorting in a high-intensity electric field. The experiments were performed on two sorts of mm-size granular materials Acrylonitrile Butadiene Styrene and High Impact Polystyrene, originating from the processing of waste electric and electronic equipment. The samples were introduced in a Polyvinyl Chloride cylinder, where a co-axial propeller entrained the plastic granules into a helical motion that favored their triboelectric charging by combining the mechanical and aerodynamical effects. The ...

2011-01-01

28

Instrumental neutron activation analysis of copper-molybdenum ores for molybdenum content determination  

International Nuclear Information System (INIS)

An instrumental neutron activation technique of determining molybdenum in ores is based on measuring gamma-activity of the "9"9Mo isotope with the use of planar and coaxial semiconductor spectrometers. A lot consisting of 50 portions, 0.5 g each, is being irradiated for 10 hours by a flow of neutrons with the density of 10"1"2 n/cm"2xsec. On the lot being allowed to stay for 3-4 days, its activity is measured during 1-5 minutes. Monoethalons based upon phenol-formaldehyde resin are used as standards. The sensitivity of the technique is 10"-"4%, reproducibility error being not higher than 10%, efficiency up to 50 portions for a working shift.

29

High-tension corona controlled ozone generator for environment protection  

International Nuclear Information System (INIS)

Engineering details of a high voltage driven corona-plasma ozone generator are described. The plasma diode of generator has coaxial cylindrical geometry with cathode located inside anode. Cathode is made of a large number of radial gas nozzles arranged on central tubular mast which admits oxygen gas. The sharp endings of the nozzles along with a set of corona rings create the high electric field at the cathode required for formation of dense corona plume responsible for O_3 evolution. A model of coronal plasma generation and ozone production is presented. The plasma formation is strongly dependent on the electric field and temperature in side diode where a high electron density in a low temperature negative corona is suited for high ozone yields. These are established by suitable regulation of A-K gap, voltage, oxygen pressure, and cathode-nozzle population.

2010-02-01

30

Development of liquid metal ion sources, focused ion beam and their applications  

International Nuclear Information System (INIS)

To suit the needs of development for manufacture VLSI, we started to investigate liquid metal ion sources (LMIS) and focused ion beam (FIB) in 1984. Many kinds of emitters viz. neddle type, co-axial type and capillary type of Ga and Au LMIS and three kinds of eutectic alloys LMIS (Au-Si, Au-Si-Be, Pd-Ni-Si-Be-B) have been tested. A program which can calculate focused ion guns has been written. Four kinds of foused ion guns have been operated, a fine beam with diametic 0.1 #mu#m is obtained. Using the FIB a scanning ion microscope has been constructed. Some tests of etching and self-developing of nitrocellulose are described. (author).

31

Degradation of antibiotics in water by non-thermal plasma treatment.  

Science.gov (United States)

The decomposition of three ?-lactam antibiotics (amoxicillin, oxacillin and ampicillin) in aqueous solution was investigated using a dielectric barrier discharge (DBD) in coaxial configuration. Solutions of concentration 100 mg/L were made to flow as a film over the surface of the inner electrode of the plasma reactor, so the discharge was generated at the gas-liquid interface. The electrical discharge was operated in pulsed regime, at room temperature and atmospheric pressure, in oxygen. Amoxicillin was degraded after 10 min plasma treatment, while the other two antibiotics required about 30 min for decomposition. The evolution of the degradation process was continuously followed using liquid chromatography-mass spectrometry (LC-MS), total organic carbon (TOC) and chemical oxygen demand (COD) analyses. PMID:21514950

2011-04-06

32

Two-phase flow characteristic of inverted bubbly, slug and annular flow in post-critical heat flux region  

Energy Technology Data Exchange (ETDEWEB)

Inverted annular flow can be visualized as a liquid jet-like core surrounded by a vapor annulus. While many analytical and experimental studies of heat transfer in this regime have been performed, there is very little understanding of the basic hydrodynamics of the post-CHF flow field. However, a recent experimental study was done that was able to successfully investigate the effects of various steady-state inlet flow parameters on the post-CHF hydrodynamics of the film boiling of a single phase liquid jet. This study was carried out by means of a visual photographic analysis of an idealized single phase core inverted annular flow initial geometry (single phase liquid jet core surrounded by a coaxial annulus of gas). In order to extend this study, a subsequent flow visualization of an idealized two-phase core inverted annular flow geometry (two-phase central jet core, surrounded by a coaxial annulus of gas) was carried out. The objective of ...

1988-01-01

33

Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The ...

2005-12-15

34

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built and tested. The results of these test, ...

2004-10-13

35

Some medical applications of thermomechanically treated titanium nickelide  

Energy Technology Data Exchange (ETDEWEB)

An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first publication the ...

2001-11-01

36

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a planar Si(Li) detector. For elements beyond Dy ...

1989-06-01

37

Natural convection cooling of a close-packed array of AGR fuel pins surrounded by graphite debris  

International Nuclear Information System (INIS)

Certain postulated faults during refuelling of AGRs may give rise to compacted fuel and graphite sleeve debris. This debris must be maintained below some safe limiting temperature. As part of a programme to assess the benefits of natural convection in cooling such debris in a region experiencing no forced cooling, a simple geometry incorporating typical debris has been studied both experimentally and by prediction. The experiment comprised an array of electrically heated fuel rods mounted co-axially in a closed cylindrical vessel and surrounded by fragments of graphite. The vessel was cooled on its cylindrical surface, the ends being insulated. Rods and vessel wall were thermocoupled. Tests covered a range of temperature and pressures in both CO_2 and N_2. Significant natural convection heat removal was demonstrated, particularly at high pressure. Predictions utilising the PHOENICS code agreed well with measured temperatures over a wide range of test conditions. ...

38

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift of the head during ...

1976-05-21

39

Limitations of traveling wave relaying for overhead EHV transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. This time-domain method offers more ...

1986-01-01

40

Electron diodes and cavity design for the new 4-MeV injector of the recirculating linear accelerator (RLA)  

International Nuclear Information System (INIS)

The authors have designed and constructed four types of electron-beam diodes for the new 4-MV RLA injector: a non-immersed foilless diode, a magnetically immersed foilless diode, a foil diode and an ion-focused foilless diode, They are tailored to fit the new injector cavity. The design goals were to produce high quality 10-kA to 20-kA electron beams with a #beta# perpendicular smaller than 0.2 and a beam radius of the order of 2 cm. These beams will be matched to the RLA IFR channel so #beta# perpendicular must be equal to or smaller than the square root of the ratio of the beam current versus Alfven current for f_e = 1. A reentrant anode geometry was selected for the injector cavity design, because it offers substantial savings on the required amount of feromagnetic cores. The inner radius of the outside shell, now only 30 cm, would have been twice as large (60 cm) if a coaxial non-reentrant geometry had been adopted. The shape of the anode and cathode electrodes ...

1991-03-01

 
 
 
 
41

Efficiency of ozone production by pulsed positive corona discharge in synthetic air  

International Nuclear Information System (INIS)

We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short (#approx#150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10"-"4-3x10"-"1 Wh l"-"1) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min"-"1). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. The ozone production yield and cost vary in the range of 15-55 g kWh"-"1 and 35-110 eV/molecule. (author)

2002-06-07

42

Determination of small amounts of elements by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The determination of small amounts of elements by radionuclide X-ray fluorescence analysis is described. Samples containing 5x10"-"4 to 5x10"-"6 g of elements were fixed on a suitable carrier. For a coaxial configuration a low-energy source of the #gamma#/X type was used, namely an annular "2"4"1Am/Ag source with an activity of 7.4x10"8 s"-"1 (20 mCi), and for a configuration with side reflection source of the #beta#/X type was used, namely "1"4"7Pm/Sm with the activity of Pm(OH)_3 approximately 3.7x1O"1"0 s"-"1 (1 Ci). Cs, Ba, La, Pr, Nd, and Ag were determined by means of the Ksub(#alpha#) line and Hg, W, Er, and Pr by means of the Lsub(#alpha#) line. For all elements studied a detection limit of the order of 10"-"7 g was achieved. (author).

1975-01-01

43

Augmentation of radiative heat transfer in an infinite cylindrical pipe enclosing a participating gas  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the range of values studied for a real gas, if ...

1992-10-01

44

Elastic flexural properties of multistranded stainless steel versus conventional nickel titanium archwires.  

Science.gov (United States)

Based on a recent investigation that modeled the elastic properties (ie, strength, stiffness and range) of multistranded wires made from linearly elastic materials, three-stranded (triple) and six-stranded coaxial (coax) stainless steel (SS) wires were compared to single-stranded (single) SS and conventional nickel titanium (NiTi) leveling wires. To measure Young's modulus of elasticity (E), flexural tests were performed with an Instron mechanical testing machine in a three-point bending arrangement having a span length of 8.9 mm or 12.5 mm. A strong correlation between wire stiffness and the area moment of inertia demonstrated that strand interaction was negligible at low activations and that E = 199 GPa was constant even for the heavily drawn coax strands. Using the Instron with an extensometer, the 0.1% yield strengths (sigma(YS)) of the single SS wires and the straight inner strands within the coax wires were tested. The ratio of the sigma(YS) to the ultimate ...

2002-08-01

45

Coilgun Launcher for Nanosatellites  

Energy Technology Data Exchange (ETDEWEB)

Nanosatellite space launches could significantly benefit from an electrically powered launch complex, based on an electromagnetic coil launcher. This paper presents results of studies to estimate the required launcher parameters and some fixed facility issues. This study is based on electromagnetic launch, or electromagnetic gun technology, which is constrained to a coaxial geometry to take advantage of the efficiency of closely-coupled coils. A baseline configuration for analysis considers a payload mass of 10 kg, launch velocity of 6 km/s, a second stage solid booster for orbital insertion, and a payload fraction of about 0.1. The launch facility is envisioned as an inclined track, 1-2 km in length, mounted on a hillside at 25 degrees aimed in the orbital inclination of interest. The launcher energy and power requirements fall in the range of 2000 MJ and 2 MW electric. This energy would be supplied by 400 modules of energy storage and magnetic coils. With a prime ...

1999-03-23

46

A Dual Expandable Nitinol Stent: The Long-term Results in Patients with Malignant Gastroduodenal Strictures  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the long-term results of a dual expandable nitinol stent for the palliative treatment of malignant gastroduodenal strictures. The dual stent consists of two stents; an outer partially nylon covered stent and an inner bare nitinol stent. The outer stent was placed into the stricture and this was followed by coaxial placement of the inner bare stent. Using fluoroscopic guidance, dual expandable stents were placed in 86 patients with inoperable malignant gastroduodenal strictures. The technical and clinical success, the complication, survival and the stent patency were evaluated during the follow-up period. Stent placement was technically successful in 83 of the 86 patients. After stent placement, 74 of the 85 patients showed improvement of their symptoms. During the mean follow-up period of 133 days, 24 patients (28%) developed recurrent symptoms due to incomplete expansion (n=1), stent migration (n=4), food impaction (n=2), granulation tissue ...

2009-12-15

47

Rack and pinion based fuelling machine of 540 MWe PHWR-from concept to refuelling  

International Nuclear Information System (INIS)

On-power refuelling is an integral feature of PHWR units. The most notable aspect of refuelling system of 540 MWe PHWR (TAPP-3 and 4) is that the FM Head is based on rack and pinion mechanism for B-ram and C-ram of Ram assembly. Latch ram used during plug operations, is assembled in between B-ram and C-ram and is moved by a ballscrew driven by oil hydraulic motors. This unique design has been employed for the first time in a PHWR unit. In comparison, B-ram is ballscrew driven and C-ram is moved by heavy water hydraulic force in FM Heads of 220 MWe PHWR units. Over the years, a number of design improvements have been carried out in the 220 MWe Fuelling Machines to meet the challenge of increasing demands of higher refuelling rates. However, in 540 MWe unit, the average refuelling rate for an equilibrium core is nearly twice that of 220 MWe units. Apart from other assemblies in FM Head, the performance of Ram assembly plays a key role in meeting this demand. The experience of ballscrew ...

2006-11-13

48

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...

2001-06-17