WorldWideScience
2

Development of New Ground Inspection Techniques for the ...  

Science.gov (United States)

Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...

3

Imaging characterization of carbon nanotube tips modified using a focused ion beam  

International Nuclear Information System (INIS)

A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.

2007-06-15

4

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if ...

2006-07-01

5

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if ...

2005-11-20

6

Reference standard for carbonaceous impurity measurements in carbon nanotubes  

Science.gov (United States)

Near-infrared spectroscopy is a convenient tool for measuring nanotube / carbonaceous impurities

2004-01-01

7

New Biomarkers Probing Depth of Cell Senescence Assessed by Laser Scanning Cytometry  

UK PubMed Central (United Kingdom)

The imaging analytical capabilities of laser scanning cytometer (LSC) have been used to assess morphological features considered to be typical of the senescent phenotype. The characteristic “flattening”...Full Text Available

2010-11-01

8

Mechanical behavior of self-assembled carbon nanotube reinforced nylon 6,6 fibers  

British Library Electronic Table of Contents (United Kingdom)

The versatile electrospinning technique was used to successfully align and disperse multiwalled carbon nanotubes (MWCNT) in nylon 6,6 matrix to obtain composite fibers. The morphology of the composite fibers and the dispersion of the CNTs within the fibers were analyzed using scanning electron microscopy (SEM) and transmission electron microscopy (TEM), respectively. TEM analysis revealed that the CNTs were well-dispersed, separated and aligned along the fiber axis. The thermal and mechanical properties of the composite fibers were characterized as a function of weight fraction of the CNTs. Incorporation of the CNTs in the fibers resulted in an increase in glass-transition temperature (Tg) by 7degreeC, indicating that the addition of CNTs has restricted the mobility of the polymer chains a...

2010-01-01

9

Effects of multiwall carbon nanotubes on the thermal and mechanical properties of medium density polyethylene matrix nanocomposites produced by a mechanical milling method  

British Library Electronic Table of Contents (United Kingdom)

Medium-density polyethylene/multiwall carbon nanotube (MDPE/MWCNT) nanocomposites were produced by a mechanical milling method using a high-energy ball mill. The MDPE and MWCNTs were added to the ball mill at a constant 20:1 weight ratio of ball/powders and milled for 10 h to obtain polyethylene matrix nanocomposites reinforced with 0.5, 1, 2.5, and 5 weight percent of MWCNTs. To clarify the role of both MWCNT content and milling time on the morphology of MDPE, some nanocomposite samples were investigated by using a scanning electron microscope. To evaluate the role of milling on the microstructure of the nanocomposites, very thin films of MDPE/MWCNTs were prepared and studied by transmission electron microscopy. Thermal behavior of these nanocomposites was investigated by using differenti...

2010-01-01

10

Single parameter analysis of hysteretic magnetic flux trapping in high T{sub c} superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high {Tc} superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-10-01

11

Single parameter analysis of hysteretic magnetic flux trapping in high T_c superconductor ribbon  

International Nuclear Information System (INIS)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high T_c superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-07-19

12

Single parameter analysis of hysteretic magnetic flux trapping in high T[sub c] superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high [Tc] superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-01-01

13

Compressive and Torsional Buckling Behavior of Carbon Nanotube Bundles  

International Nuclear Information System (INIS)

The compressive and torsional buckling behavior of carbon nanotube bundles at room temperature is examined with classical molecular dynamics simulation. The critical compressive load and stiffness of a single carbon nanotube in the bundle are found to be similar to those of individual carbon nanotubes. However, the critical torsional moment and stiffness of a single carbon nanotube in the bundle are found to be higher than those of individual carbon nanotubes. In addition, this study demonstrates that van der Waals interactions between the nanotubes in the bundle significantly affect the critical compressive load of the nanotube bundle.

2007-08-01

14

Field trial of a fast single-pass transmit-receive probe during Gentilly II steam generator tube inspection  

International Nuclear Information System (INIS)

A new generation of transmit-receive single-pass probes, denoted as C6 or X probe, was field tested during the Gentilly II, 2000 steam generator tube inspection. This probe has a performance equivalent to rotating probes and can be used for tubesheet and full-length inspection at an inspection speed equivalent to that of bobbin probes. Existing C3 transmit-receive probes have been demonstrated to be effective in detecting circumferential cracks. The C5 probe can detect both circumferential and axial cracks and volumetric defects but cannot discriminate between them. The C6 probe expands on the capabilities of both probes in a single probe head. It can simultaneously detect and discriminate between circumferential and axial cracks to satisfy different plugging criteria. It has ...

2000-11-19

15

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

16

Dye-sensitized solar cells based on anatase TiO2 hollow spheres/carbon nanotube composite films  

British Library Electronic Table of Contents (United Kingdom)

Dye-sensitized solar cells (DSSCs) based on anatase TiO2 hollow spheres (TiO2HS)/multi-walled carbon nanotubes (CNT) nanocomposite films are prepared by a directly mechanical mixing and doctor blade method. The prepared samples are characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, UV-vis absorption spectroscopy and N2 adsorption-desorption isotherms. The photoelectric conversion performances of the DSSCs based on TiO2HS/CNT composite film electrodes are also compared with commercial-grade Degussa P25 TiO2 nanoparticles (P25)/CNT composite solar cells at the same film thickness. The results indicate that the photoelectric conversion efficiencies () of the TiO2HS/CNT composite DSSCs are dependent on CNT loading in the electrodes. A small amou...

2011-01-01

17

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

Energy Technology Data Exchange (ETDEWEB)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to ...

1996-01-01

18

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

International Nuclear Information System (INIS)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to ...

1992-01-01

19

Evaluation of heterogeneity in thickness of passive films on pure iron by scanning electrochemical microscopy  

Energy Technology Data Exchange (ETDEWEB)

Scanning electrochemical microscopy (SECM) was applied to evaluate the heterogeneity of a passive film formed on a pure iron electrode in deaerated pH 8.4 borate solution. A probe current image of SECM was measured with a tip-generation/sub-strate-collection (TO/SC) mode in deaerated pH 8.4 borate solution containing 0.03 moldm{sup -3} Fe(CN){sub 6}{sup 4-} as a mediator. The difference in thickness of passive films formed on two iron plates at different potentials could be evaluated from the probe current image. The probe current image of the passivated iron surface with distinctive crystal grains was composed of the patch patterns, the shapes of which coincided completely with the shapes of the substrate crystal grains. The probe current flowed above the grain surface oriented to {l_brace}100{r_brace} plane was less than that above the grain surface oriented to ...

1999-04-01

20

Evaluation of optimum sheath electric field for selective production of metallic carbon nanotubes  

International Nuclear Information System (INIS)

We estimate the optimum electric field at the sheath edge and the minimum interval among the nanotubes to promote the growth of armchair-type nanotubes (metallic character) as a function of the tube length. On the basis of the electric charge distribution in a nanotube and the optimum electric filed E*_1 at the tip of a nanotube evaluated using the Hueckel-Poisson method, we calculate the structure of the electric field lines outside a nanotube in the sheath region. As the tube length increases, the E*_1 decreases. To maintain the chemical activity at the tip, the sheath electric field must be decreased. We show the decreasing rate of the sheath field to the tube length.

2006-03-21

21

Synthesis and enhanced light absorption of alumina matrix nanocomposites containing multilayer oxide nanorods and silver nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

In this paper, multilayer oxide nanorods were deposited in the nanopores of anodic aluminum oxide (AAO) via solution infiltration followed by heat treatment. The nanorods have a core-shell structure. First, the shell (nanotube) with the thickness of about 40nm was made of TiO"2 through the hydrolysis of (NH"4)"2TiF"6. Second, silver nanoparticles with the diameter of about 3nm were added into the TiO"2 layer through thermal decomposition of AgNO"3 at elevated temperatures. Then, cylindrical cores (nanorods) of CoO and ZnO with 200nm diameter were prepared, respectively. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and composition of the nanorods. UV-vis light absorption measurements in the wavelength range from 350 to...

2011-01-01

22

Improved eddy-current inspection for steam generator tubing  

International Nuclear Information System (INIS)

Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generators test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking, and intergranular attack. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different ...

1990-03-01

23

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

Energy Technology Data Exchange (ETDEWEB)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD ...

2006-07-01

24

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

International Nuclear Information System (INIS)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD ...

2005-11-20

27

Local thermal property analysis by scanning thermal microscopy of an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment  

International Nuclear Information System (INIS)

Scanning thermal microscopy (SThM) was used to map thermal conductivity images in an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment (SMAT). It is found that the deformed surface layer shows different thermal conductivities that strongly depend on the grain size of the microstructure: the thermal conductivity of the nanostructured surface layer decreases obviously when compared with that of the coarse-grained matrix of the sample. The role of the grain boundaries in thermal conduction is analyzed in correlation with the heat conduction mechanism in pure metal. A theoretical approach, based on this investigation, was used to calculate the heat flow from the probe tip to the sample and then estimate the thermal conductivities at different scanning positions. Experimental results and theoretical calculation demonstrate that SThM can be used as a tool for the thermal property and ...

2006-06-15

28

Peroxi-coagulation degradation of C.I. Basic Yellow 2 based on carbon-PTFE and carbon nanotube-PTFE electrodes as cathode  

International Nuclear Information System (INIS)

The electrochemical treatment of solutions containing C.I. Basic Yellow 2 (BY2) in aqueous solutions with carbon-PTFE (polytetrafluoroethylene) and carbon nanotube (CNT)-PTFE electrodes as cathode has been studied. The fabricated electrodes were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The amount of electrogenerated H2O2 on the surface of these electrodes was investigated, too. The results showed that the amount of H2O2 obtained with the CNT-PTFE electrode was nearly three times higher than that of carbon-PTFE electrode. The decolorization efficiency of BY2 in peroxi-coagulation process reached 62% and 96% in the first 10 min by carbon-PTFE and CNT-PTFE electrodes at 100 mA, respectively. The effect of operational parameters such as applied current, initial pH and initial dye concentration was studied in an attempt to reach higher decolorization efficiency. The degradation and mineralization of BY2 ...

2009-11-01

29

Light-weight free-standing carbon nanotube-silicon films for anodes of lithium ion batteries.  

Science.gov (United States)

Silicon is an attractive alloy-type anode material because of its highest known capacity (4200 mAh/g). However, lithium insertion into and extraction from silicon are accompanied by a huge volume change, up to 300%, which induces a strong strain on silicon and causes pulverization and rapid capacity fading due to the loss of the electrical contact between part of silicon and current collector. Si nanostructures such as nanowires, which are chemically and electrically bonded to the current collector, can overcome the pulverization problem, however, the heavy metal current collectors in these systems are larger in weight than Si active material. Herein we report a novel anode structure free of heavy metal current collectors by integrating a flexible, conductive carbon nanotube (CNT) network into a Si anode. The composite film is free-standing and has a structure similar to the steel bar reinforced concrete, where the infiltrated CNT network functions as both ...

2010-07-27

30

Reactions of the inner surface of carbon nanotubes and nanoprotrusion processes imaged at the atomic scale  

British Library Electronic Table of Contents (United Kingdom)

Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...

2011-01-01

31

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves ...

1997-11-16

32

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves ...

1997-07-01

33

Reviewing the Environmental and Human Health Knowledge Base of Carbon Nanotubes  

UK PubMed Central (United Kingdom)

Carbon nanotubes (CNTs) are considered one of the most promising materials in nanotechnology, with attractive properties for many technologic applications. The different synthesis, purification, and...Full Text Available

2007-08-01

34

Titanate nanotubes as superior adsorbents for removal of lead(II) ions from water  

British Library Electronic Table of Contents (United Kingdom)

Titanate nanotubes were hydrothermally synthesized and their adsorption performances for lead(II) ion removal were studied. The results showed that titanate nanotubes ruptured in the adsorption process resulting in two distinct adsorption stages, thus achieving a maximum adsorption capacity of 3.752mmolg^-^1 of lead(II). Furthermore, it was found that the regeneration of titanate nanotubes loaded with the lead(II) ions can be readily achieved using the saturated EDTA disodium salt aqueous solution, thereby avoiding the trouble of disposal of adsorbent. The adsorption mechanism was also discussed in detail.

2010-01-01

36

Single-Walled Carbon Nanotubes Targeted to the Tumor ...  

Science.gov (United States)

... 1981. Retention of diphenyls, terphenyls, phenylalkanes and fluorene on graphitized thermal carbon black. Chromatographia 14:510-514. ...

2009-09-01

37

Photon-assisted spin-polarized transport in carbon nanotubes with impurities  

International Nuclear Information System (INIS)

Impurity effects on the photon-assisted spin-polarized transport through armchair carbon nanotubes connected with ferromagnetic leads are investigated theoretically. The impurity induces one resonant state whose position depends on the impurity strength, which can break the electron-hole symmetry. Whether the impurity suppresses or enhances the spin-coherent current depends on the nanotube length. When the microwave fields are applied on the nanotube, additional small side peaks caused by the photon-assisted tunneling are found. With increasing the impurity strength, one new current peak appears under the influence of both the microwave fields and the impurity.

2006-12-25

38

Control of Effluent Gases from Solid Waste Processing Using Carbon Nanotubes  

Science.gov (United States)

One of the major problems associated with solid waste processing technologies is the release of

2005-01-01

39

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

40

Performance characterization of a volumetric breast ultrasound scanner  

Science.gov (United States)

The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and ...

2007-03-01

41

Electrospun porous SnO2 nanotubes as high capacity anode materials for lithium ion batteries  

British Library Electronic Table of Contents (United Kingdom)

Porous SnO2 nanotubes were prepared via electrospinning followed by calcination in air. As anode materials for lithium ion batteries, the porous nanotubes delivered a high discharge capacity of 807mAhg^-^1 after 50cycles. Even after cycled at high rates, the electrode still retained a high fraction of its theoretical capacity. Such excellent performances of porous SnO2 nanotubes could be attributed to the porous and hollow structure which facilitated liquid electrolyte diffusion into the bulk materials and buffered large volume changes during lithium ions insertion/extraction. Furthermore, the nanoparticles of nanotubes provided the shorter diffusion length for lithium ions insertion which benefited in retaining the structural stability and good rate performance. Our results demonstrated t...

2010-01-01

42

PROBING NEAR-SURFACE ATMOSPHERIC TURBULENCE WITH LIDAR MEASUREMENTS AND HIGH-RESOLUTION HYDRODYNAMIC MODELS  

Energy Technology Data Exchange (ETDEWEB)

As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution and coverage of the ...

2000-11-01

43

Critical current measurements of high Tc superconductors in a scanning low temperature cryostat  

Energy Technology Data Exchange (ETDEWEB)

Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high {Tc} superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high {Tc} superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is noncontacting; however, it also averages the measurement over a large ...

1991-01-01

44

Electrospun porous SnO{sub 2} nanotubes as high capacity anode materials for lithium ion batteries  

Energy Technology Data Exchange (ETDEWEB)

Porous SnO{sub 2} nanotubes were prepared via electrospinning followed by calcination in air. As anode materials for lithium ion batteries, the porous nanotubes delivered a high discharge capacity of 807 mAh g{sup -1} after 50 cycles. Even after cycled at high rates, the electrode still retained a high fraction of its theoretical capacity. Such excellent performances of porous SnO{sub 2} nanotubes could be attributed to the porous and hollow structure which facilitated liquid electrolyte diffusion into the bulk materials and buffered large volume changes during lithium ions insertion/extraction. Furthermore, the nanoparticles of nanotubes provided the shorter diffusion length for lithium ions insertion which benefited in retaining the structural stability and good rate performance. Our results demonstrated that this simple method could be extended for the synthesis of porous metal oxide ...

2010-10-15

45

PROBE FOR FLOW PASSAGE INSPECTION  

J-STORE (Japan)

Full Text Available

2007-05-11

47

Length-sorted semiconducting carbon nanotubes for high-mobility thin film transistors  

British Library Electronic Table of Contents (United Kingdom)

We have developed a process for chemical purification of carbon nanotubes for solution-processable thin-film transistors (TFTs) having high mobility. Films of the purified carbon nanotubes fabricated by simple drop coating showed carrier mobilities as high as 164 cm2V?1s?1, normalized transconductances of 0.78 Sm?1, and on/off current ratios of 106. Such high performance requires the preparation of a suspension of micrometer-long and highly purified semiconducting single-walled carbon nanotubes (SWCNTs). Our purification process includes length and electronic-type selective trapping of SWCNTs using recycling gel filtration with a mixture of surfactants. The results provide an important milestone toward printed high-speed and large-area electronics with roll-to-roll and ink-jet device fabri...

2011-01-01

48

Molecular characterization of the Spirometra mansonoides genome: renaturation kinetics, methylation, and hybridization to human cDNA probes.  

Science.gov (United States)

High molecular weight DNA from pleroceroid larvae of the tapeworm Spirometra mansonoides was purified from isolated nuclei by conventional techniques. The DNA so isolated has a melting temperature (Tm) of 87 degrees C and a guanine plus cytosine (G/C) content of 44%. 5-Methyl cytosine could not be detected in plerocercoid DNA by HPLC analysis of DNA hydrolysates, by radiolabeling 5'-termini of MspI digests with polynucleotide kinase, or by comparing restriction patterns generated by MspI and HpaII. Renaturation kinetics demonstrated that the genome of S. mansonoides contains repetitive as well as single copy sequences and has a genome size estimated at approx. 1.6 X 10(9) bp. Hybridization was carried out between plerocercoid DNA and cDNAs for human beta-actin, alpha-tubulin and growth hormone (hGH). Rationale for this analysis was based on known homologies among actin and tubulin genes in numerous species and on apparent similarities between hGH and a plerocercoid growth factor that ...

1990-06-21

49

INFLATABLE EDDY CURRENT INSPECTION PROBE FOR ...  

Science.gov (United States)

... INTERMEDIATE TO THE CENTRALIZERS IS A SENSING SECTION COMPRISED OF MULTIPLE EDDY CURRENT PROBES ON FLEXIBLE ...

1981-12-01

50

X-ray microanalysis of Al/Zr multilayers in the transmission electron microscope  

International Nuclear Information System (INIS)

A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating ...

1997-04-04

51

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored ...

2008-04-15

52

Draft Genome Sequence of Shewanella sp. Strain HN-41, Which Produces Arsenic-Sulfide Nanotubes.  

Science.gov (United States)

The dissimilatory metal reducing bacterium Shewanella sp. strain HN-41 was first reported to produce novel photoactive As-S nanotubes via reduction of As(V) and S(2)O(3)(2-) under anaerobic conditions. Here we report the draft genome sequence and annotation of strain HN-41. PMID:21868804

2011-09-01

53

New implementation of a shear-force microscope suitable to study topographical features over wide areas  

International Nuclear Information System (INIS)

A new implementation of a shear-force microscope is described that uses a shear-force detection system to perform topographical imaging of large areas (#approx#1x1 mm"2). This implementation finds very interesting application in the study of archeological or artistic samples. Three dc motors are used to move a sample during a scan, allowing the probe tip to follow the surface and to face height differences of several tens of micrometers. This large-area topographical imaging mode exploits new subroutines that were added to the existing homemade software; these subroutines were created in Microsoft VISUAL BASIC 6.0 programming language. With this new feature our shear-force microscope can be used to study topographical details over large areas of archaeological samples in a nondestructive way. We show results detecting worn reliefs over a coin.

2006-09-01

54

Morphology, structure, and conductivity of polypyrrole prepared in the presence of mixed surfactants in aqueous solutions  

British Library Electronic Table of Contents (United Kingdom)

Polypyrrole (PPy) was prepared from different mixed-surfactant solutions with ammonium persulfate as an oxidant. Three types of combinations were selected, including cationic/anionic, cationic/nonionic, and anionic/nonionic mixed-surfactant solutions. The surfactants used in the experiments included cetyltrimethylammonium bromide (cationic surfactant), sodium dodecyl sulfate (anionic surfactant), sodium dodecyl sulfonic acid salt (anionic surfactant), poly(vinyl pyrrolidone) (nonionic surfactant), and poly(ethylene glycol) (nonionic surfactant). The morphology, structure, and conductivity of the resulting PPy were investigated in detail with scanning electron microscopy, Fourier transform infrared spectra, and the typical four-probe method, respectively. The results showed that the interac...

2007-01-01

55

Morphology evolution of Ir-Nb-X (X = Hf, Ta, or Ti) ternary alloys  

Energy Technology Data Exchange (ETDEWEB)

The microstructure evolution of nine samples from three Ir-base ternary systems, Ir-Nb-Hf, Ir-Nb-Ta, and Ir-Nb-Ti, was investigated by microstructure observation using scanning electron microscopy (SEM), composition map-analysis using electron probe microscopy analysis (EPMA), and phase determination using X-ray diffraction (XRD) patterns. The fcc/L1{sub 2} two-phase structure was detected in all the samples. Lattice misfits between fcc and L1{sub 2} phases were calculated. Ir-Nb-Ta and Ir-Nb-Ti alloys exhibited a microstructure quite similar to that of Ni-base superalloys, and the cuboidal L1{sub 2} precipitates in Ir-Nb-Ta and Ir-Nb-Ti alloys could maintain up to 1900 {sup o}C.

2007-01-31

56

Metallurgical Investigation of a Prematurely Failed Concentric Reducer Tube Used in a Hot-Rolling Mill  

British Library Electronic Table of Contents (United Kingdom)

A concentric reducer tube, which was a part of the top exit roughing hydraulic descaler in a hot strip mill failed prematurely under working pressure. A detailed metallurgical investigation comprising physical examination, optical microscopy, scanning electron microscopy, and electron probe microanalysis was carried out to find out the genesis of the failure. Physical examination revealed cracks located symmetrically around the circumference of the tube that ran along its full length, up to the weld beads at both ends. Optical microscopy of etched samples revealed a banded ferrite-pearlite structure and the existence of forging folds near the change-in-section(160? fillets). Cracks were found to initiate from these forging folds. No structural abnormalities were found in the weld beads and...

2007-01-01

57

Magnetic layer formation on plasma nitrided CoCrMo alloy  

British Library Electronic Table of Contents (United Kingdom)

In this study structural and magnetic character of the expanded austenite phase (gN) layer formed on a medical grade CoCrMo alloy by a low-pressure Radio-Frequency plasma nitriding process was investigated. The formation of the expanded austenite phase is facilitated at a substrate temperature near 400^oC for 1, 2, 4, 6 and 20h under a gas mixture of 60% N2-40% H2. The magnetic state of the gN layers was determined by a surface sensitive technique, magneto-optic Kerr effect (MOKE), and with a scanning probe microscope in magnetic force mode (MFM). Strong evidence for the ferromagnetic nature of the gN-(Co,Cr,Mo) phase is provided by the observation of stripe domain structures and the hysteresis loops. The ferromagnetic state for the gN phase observed here is mainly linked to large lattice ...

2011-01-01

58

Effect of Al and AlP on the microstructure of Mn-30 wt.%Si alloy  

Energy Technology Data Exchange (ETDEWEB)

Effect of Al and AlP particles on the microstructure of near eutectic Mn-Si alloy (Mn-30 wt.%Si) was studied by Electron Probe Micro-analyzer (EPMA) and Differential Scanning Calorimeter (DSC). Crystal lattice correspondence analyses show that both Al and AlP have good lattice matching coherence relationships with MnSi phase, and the addition of Al and AlP particles results in an abnormal eutectic structure, i.e. the eutectic constitution MnSi and Mn{sub 5}Si{sub 3} precipitate separately: MnSi precipitates firstly, and then the Mn{sub 5}Si{sub 3} phase.

2008-04-15

59

Desorption of polycyclic aromatic hydrocarbons from carbon nanomaterials in water  

Energy Technology Data Exchange (ETDEWEB)

Desorption behavior of pyrene, phenanthrene and naphthalene from fullerene, single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs) was examined. Available adsorption space of carbon nanotubes (CNTs) was found to be the cylindrical external surface, neither the inner cavities nor inter-wall spaces due to impurities in the CNTs and restricted spaces (0.335 nm) of the MWCNTs, respectively. Desorption hysteresis was observed for fullerene but not for CNTs. Deformation-rearrangement was proposed to explain the hysteresis of polycyclic aromatic hydrocarbons (PAHs) for fullerene, due to the formation of closed interstitial spaces in spherical fullerene aggregates. However, long, cylindrical carbon nanotubes could not form such closed interstitial spaces in their aggregates due to their length, thus showing no significant hysteresis. High adsorption capacity and reversible adsorption ...

2007-01-15

60

Sol-gel coatings with phosphonate functionalities for surface modification of magnesium alloys  

International Nuclear Information System (INIS)

Hybrid organic-inorganic coatings with phosphonate functionalities have been synthesized and evaluated as prospective surface treatments for magnesium materials. These coatings have been processed via a sol-gel route by hydrolysis and condensation of a mixture of diethylphosphonatoethyltriethoxy-silane and tetraethoxy-silane with variable molar ratios. The coatings morphology and the surface chemistry at the coating/substrate interface have been characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, "3"1P nuclear magnetic resonance spectroscopy, and time-of-flight secondary ion mass spectrometry. The corrosion protection performance of the coatings deposited on magnesium alloy AZ31B has been examined by a group of electrochemical techniques including potentiodynamic polarization and electrochemical impedance spectroscopy. In addition, a scanning Kelvin probe technique has been used to ...

2006-08-30

61

Physico-chemical, optical and electrochemical properties of iron oxide thin films prepared by spray pyrolysis  

International Nuclear Information System (INIS)

Iron oxide thin films were prepared by spray pyrolysis technique onto glass substrates from iron chloride solution. They were characterized by X-ray diffractometry (XRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and (UV-vis) spectroscopy. The films deposited at T _s #<=# 450 deg. C were amorphous; while those produced at T _s_u_b = 500 deg. C were polycrystalline #alpha#-Fe_2O_3 with a preferential orientation along the (1 0 4) direction. By observing scanning electron microscopy (SEM), it was seen that iron oxide films were relatively homogeneous uniform and had a good adherence to the glass substrates. The grain size was found (by RX) between 19 and 25 nm. The composition of these films was examined by X-ray photoelectron spectroscopy and electron probe microanalysis (EPMA). These films exhibited also a transmittance value about 80% in the visible and infrared range. The cyclic ...

2006-12-15

62

Probe-Flaw Interactions with Eddy Current Array Probes  

Science.gov (United States)

... The development of various modeling methods for conventional eddy current probes (absolute, differential, two-port, etc.) has led to a general ...

63

Linearized augmented-plane-wave method for quasi-unidimensional systems: Carbyne and nanotube (Sc@C{sub 20})  

Energy Technology Data Exchange (ETDEWEB)

The advent of carbon nanotubes, which are graphite layers convoluted in cylinders several nanometers in diameter and several micrometers in length, as well as the experiments on implanting metal atoms in such tubes open the way to producing nanoconductors and other materials with unique properties. For theorists, the basic challenge is interpreting and predicting the structure and properties of these systems. The linearized augmented-plane-wave method (LAPW) is one of the most accurate methods in the theory of the electronic structure of solids. A generalization of this method for quasi-two-dimensional systems, surface electronic states, and layered crystals is known. The LAPW theory for quasi-unidimensional systems, which exhibit translational symmetry in one direction, has been absent thus far. In this paper, the authors suggest a version of such a theory and use this method to calculate the electronic structure of carbyne (a linear chain of carbon atoms) and ...

1995-10-01

64

Effects of C-60 fullerenes and carbon nanotubes on marine mussels.  

Environmental Research Database

Objectives1. We will use reduction of lysosomal stability as an indicator of cell injury induced by C-60 fullerenes and carbon nanotubes in the liver analogue or digestive gland (hepatopancreas) of marine mussels. Molluscan hepatopancreatic digestive cells are key to normal function and are a sensitive key interface with the environment. Reduction of lysosomal stability is mechanistically linked with impaired health of the whole animal. 2. We will also test the hepatopancreatic digestive cells for evide [continued...]DescriptionNanotechnology is a major innovative scientific and economic growth area, which may present a variety of hazards for environmental and human health. The surface properties and very small size of nanoparticles and nanotubes provides surfaces that may bind and transport toxic chemical pollutants, as well as possibly being toxic in their own right by generating reactive oxygen species (ROS). There is a wealth of evidence ...

2008-01-25

65

Scanning Electron Microscope Examination of Cotton Linters ...  

Science.gov (United States)

... TECHNICAL REPORT ARBRL-TR-02476 SCANNING ELECTRON MICROSCOPE ... SCANNING ELECTRON MICROSCOPE EXAMINATION OF ...

1983-03-01

67

SPECIAL EDDY CURRENT PROBES FOR HEAT ...  

Science.gov (United States)

... Accession Number : ADD326926. Title : SPECIAL EDDY CURRENT PROBES FOR HEAT EXCHANGER INSPECTION. Corporate Author : ...

1986-11-01

68

OPTIMIZATION OF EDDY CURRENT PROBES FOR NDT OF ...  

Science.gov (United States)

... Accession Number : ADD321199. Title : OPTIMIZATION OF EDDY CURRENT PROBES FOR NDT OF CARBON FIBER COMPOSITES. ...

1985-04-01

69

Multiple-Element Eddy Current Probes for Enhanced ...  

Science.gov (United States)

... Accession Number : ADD335251. Title : Multiple-Element Eddy Current Probes for Enhanced Inspection,. Corporate Author : ...

1993-07-01

70

Characterization of Absolute-Resonant Eddy Current Probes,  

Science.gov (United States)

... Accession Number : ADD335809. Title : Characterization of Absolute-Resonant Eddy Current Probes,. Corporate Author : ...

71

Advanced Nondestructive Evaluation (NDE) for Retirement for ...  

Science.gov (United States)

... 21 2.3 Eddy Current Probes ..... 22 2.3.1 Improved Probe Internal ...

2000-08-01

72

Membrane nanotubes induced by aqueous phase separation and stabilized by spontaneous curvature  

UK PubMed Central (United Kingdom)

Tubular membrane structures are widespread in eukaryotic cells, but the mechanisms underlying their formation and stability are not well understood. Previous work has focused on tube extrusion from...Full Text Available

2011-03-22

73

Electrochemical characterisation of patterned carbon nanotube electrodes on silane modified silicon  

Energy Technology Data Exchange (ETDEWEB)

Previously we have used atomic force anodisation lithography, with a self-assembled monolayer of hexadecyltrichlorosilane as a resist, to pattern silicon oxide nanostructures onto a p-type silicon (1 0 0) substrate. A condensation reaction was used to immobilise carbon nanotubes with high carboxylic acid functionality directly to the silicon oxide. A further condensation reaction using this surface attached the molecule ferrocenemethanol to the bound nanotubes. These new nanostructures were used as electrodes to observe the oxidation and reduction of ferrocene. However, because the small currents measured are near the detection limits of the electrochemical system used, important electrode kinetics could not to be obtained. A scribing approach made larger regions of oxidised silicon leading to the creation of larger scale patterned arrangements of carbon nanotubes allowing measurement of important electrochemical parameters ...

2008-07-20

74

Carbon nanotube coating silicon doped with Cr as a high capacity anode  

Energy Technology Data Exchange (ETDEWEB)

Effects of dopant and coating carbon nanotube on anodic performance of Si were studied for metallic anode Li ion rechargeable battery with large capacity. Although the large Li intercalation capacity higher than 1500mAhg{sup -1} is exhibited on pure Si, it decreased drastically with increasing cycle number. Increasing the electrical conductivity by doping Cr or B is effective for increasing the initial capacity and the cycle stability of Si for Li intercalation. Coating semiconductive Si with the carbon nanotube by decomposition of hydrocarbon is effective for increasing the cycle stability, though the initial Li intercalation capacity slightly decreased. Conducting binder is also important for increasing the cycle stability and it was found that Li intercalation capacity higher than 1500mAhg{sup -1} can be sustained by using poly vinyliden fruolide. Consequently, reversible Li intercalation capacity of 1500mAhg{sup -1} was successfully ...

2005-08-26

75

Synthesis and characterization of Rosebengal/folicacid-functionalized multiwall carbon nanotubes  

British Library Electronic Table of Contents (United Kingdom)

Multiwall carbon nanotubes (MWCNTs) were functionalized with a photosensitizer, rosebengal (RB), and folicacid (FA), an anti-cancer drug simultaneously and individually, which was characterized with various analytical instruments like Fourier Transform Iinfrared (FTIR) spectroscopy, UV?Vis spectroscopy, Thermogravimetric analysis (TGA), Photoluminescence (PL) spectroscopy, X-ray photoelectron spectroscopy (XPS), and Transmission electron microscopy (TEM). FTIR spectra confirmed the chemical modification of MWCNT. The chemical functionalization of MWCNT with RB was further supported by UV?Vis and PL spectra.

2011-01-01

76

Mechanical Properties of Carbon Nanotubes / Hydroxyapatite Composites Prepared by Spark Plasma Sintering  

International Nuclear Information System (INIS)

In this study, Multi-Walled Carbon Nanotubes (MWCNTs) / Hydroxylapatite (HAp) composites were made to improve mechanical properties by using Spark Plasma Sintering (SPS) method. Slurry 6 mol of CaHPO4#centre dot#2H2O (DCPD), 4 mol calcium hydroxide and MWCNTs were mixed and sintered by using SPS at 5-120 MPa pressure, 1200-1250 deg. C and in vacuum or N2 atmosphere. The fracture toughness of sintered MWCNTs/HAp composites was increased.

2006-05-05

77

Cross-stacked carbon nanotube sheets uniformly loaded with SnO{sub 2} nanoparticles: a novel binder-free and high-capacity anode material for lithium-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

SnO{sub 2}-carbon nanotube (CNT) composite sheets are synthesized using poly(vinylpyrrolidone) to uniformly load a monolayer of SnO{sub 2} nanoparticles onto the surfaces of CNTs and CNT bundles within cross-stacked CNT sheets. When they are used as high-capacity (over 850 mA h g{sup -1}) and binder-free anodes in rechargeable lithium-ion batteries, they exhibit good cycle performance. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

2009-06-12

78

High Resolution Eddy Current Probes for Non Destructive Testing  

Science.gov (United States)

New industrial Non Destructive Testing requires the development of new probes: technologies such as high spatial resolution probes for small breaking flaws detection or flexible probes for complex curved surfaces inspection. The CEA/LIST has designed and integrated 2 probes to answer industrial's constraints. The first one is based on Giant Magneto-Resistance and is able to detect 50 ?m3 flaws. The second one is based on micro-coils etched on kapton and its flexibility is adapted to curved surfaces inspection. Both are multi-elements probes, allowing fast inspection. This paper presents those new probes, their design and their performances.

2008-02-01

79

Surface hardening utilizing high-density plasma nitriding on stainless steel alloys  

Energy Technology Data Exchange (ETDEWEB)

By using a plasma nitriding procedure at the PUPR Mirror Cusp Plasma machine, surface hardness is increased in 302/304-type stainless steel samples by exposing them to high-ion-density plasma at high vacuum. This method successfully dopes the surface of the material with strengthening nitrogen ions, without the use of chemical procedures that sacrifice the resistance to corrosion of the given material. A 500 V negative bias is placed on the sample exposed to the nitrogen plasma, where high-energy ions are therefore attracted and immersed into the metallic matrix microns into the surface of the stainless steel. This potential maintains a constant surface temperature at approximately 800 deg. C. The plasma parameters including ion density and plasma temperature were diagnosed using single Langmuir probes. The stainless steel samples were then tested using scanning electron microscopy (SEM), and Vickers micro-hardness testing to determine the ...

2008-10-15

80

Surface hardening utilizing high-density plasma nitriding on stainless steel alloys  

International Nuclear Information System (INIS)

By using a plasma nitriding procedure at the PUPR Mirror Cusp Plasma machine, surface hardness is increased in 302/304-type stainless steel samples by exposing them to high-ion-density plasma at high vacuum. This method successfully dopes the surface of the material with strengthening nitrogen ions, without the use of chemical procedures that sacrifice the resistance to corrosion of the given material. A 500 V negative bias is placed on the sample exposed to the nitrogen plasma, where high-energy ions are therefore attracted and immersed into the metallic matrix microns into the surface of the stainless steel. This potential maintains a constant surface temperature at approximately 800 deg. C. The plasma parameters including ion density and plasma temperature were diagnosed using single Langmuir probes. The stainless steel samples were then tested using scanning electron microscopy (SEM), and Vickers micro-hardness testing to determine the ...

2008-10-01

81

Structure and Function Evolution of Thiolate Monolayers on Gold  

Energy Technology Data Exchange (ETDEWEB)

The use of n-alkanethiolate self-assembled monolayers on gold has blossomed in the past few years. These systems have functioned as models for common interfaces. Thiolate monolayers are ideal because they are easily modified before or after deposition. The works contained within this dissertation include interfacial characterization (inbred reflection absorption spectroscopy, ellipsometry, contact angle, scanning probe microscopy, and heterogeneous electron-transfer kinetics) and various modeling scenarios. The results of these characterizations present ground-breaking insights into the structure, function, and reproducible preparation of these monolayers. Surprisingly, three interfacial properties (electron-transfer, contact angle, and ellipsometry) were discovered to depend directly on the odd-even character of the monolayer components. Molecular modeling was utilized to investigate adlayer orientation, and suggests that these effects are ...

2006-05-01

82

Some computer simulations of semiconductor thin film growth and strain relaxation in a unified atomistic and kinetic model  

Energy Technology Data Exchange (ETDEWEB)

An overview is provided of an evolving atomistic and kinetic model of semiconductor growth that unifies the main features of strain relaxation in low and high lattice misfit heteroepitaxy. The model reveals a kinetic pathway for dislocation formation during growth with little or no energy cost at low misfits, thus providing a way out of the longstanding dilemma of too high dislocation nucleation energies predicted by classical theories of the equilibrium behavior of a fixed number of particles at low misfits. The essential kinetic process underlying the model are identified on the basis of comparison of the predictions of kinetic Monte-Carlo simulations of growth with real-time or in-situ data obtained in such experiments as reflection high-energy electron diffraction (RHEED) and scanning probe microscopy (SPM). Relative significance of these atomistic kinetic processes is shown to naturally lead to strain relaxation via defect initiation at ...

1996-12-31

83

Effect of substrate temperature on structural properties and corrosion resistance of carbon thin films used as bipolar plates in polymer electrolyte membrane fuel cells  

International Nuclear Information System (INIS)

In this work, the effects of substrate temperature that was changed from 100 to 500 "oC on the structural, chemical and electrical properties of carbon films, prepared by direct current magnetron sputtering technique, on 316L stainless steel as bipolar plate had been investigated. Raman spectroscopy and scanning electron microscopy (SEM) were performed to study the structure and the morphology of the deposited films, respectively. The corrosion resistance and the electrical resistivity were carried out by using corrosion tests and four point-probe technique. The results show that the carbon films change the structure from amorphous to graphite-like by increasing temperatures. At the temperatures higher than 300 "oC, the holes and porosities are formed on the film indicating a decrease of film quality. According to our results, corrosion resistance and electrical properties are depended strongly on the substrate temperature.

2010-07-23

84

Characterization of spent fuel approved testing material--ATM-104  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material 104 (ATM-104), which is spent fuel from Assembly DO47 of the Calvert Cliffs Nuclear Power Plant (Unit 1), a pressurized-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-104 consists of 128 full-length irradiated fuel rods with rod-average burnups of about 42 MWd/kgM and expected fission gas release of about 1%. A variety of analyses were performed to investigate cladding characteristics, radionuclide inventory, and redistribution of fission products. Characterization data include (1) fabricated fuel design, irradiation history, and subsequent storage and handling history; (2) isotopic ...

1991-12-01

85

Alloys and oxides on carbon-supported Pt-Sn electrocatalysts for ethanol oxidation  

Energy Technology Data Exchange (ETDEWEB)

This work reports studies of ethanol oxidation on Pt-Sn/C catalysts with nearly the same particle size and identical overall composition having different amounts of oxide and alloyed phases. Results of characterization of physical properties by transmission electron microscopy (TEM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), X-ray photoelectron spectroscopy (XPS), and in situ dispersive X-ray absorption spectroscopy (DXAS) are presented. The variation in the amount of oxide and alloyed phases, promoted by heat treatments in mild temperature conditions, does not produce any significant particle growth. Cyclic voltammetry and oxidation of adsorbed CO in acid medium are used to probe the surface conditions. Data on the electrocatalytic activity towards ethanol oxidation, obtained by potential sweeps and chronoamperometry, are discussed and correlate well with the physical properties. This study, carried out in the absence ...

2010-06-01

86

In-situ examination of turbine components (blade roots, rotor steeple grooves and disk-blade rim attachments) of low-pressure steam turbine, using phased array technology  

Energy Technology Data Exchange (ETDEWEB)

A feasibility study test and 3 field trials were performed at Darlington NGS in 1996, 1999 and 2000 on ABB LP turbines. The scope of these trials was to commission in-situ automatic phased array systems capable to inspect blade roots and rotor steeples of L-0 and L-1 rows. GE disk-blade rim attachments were inspected at Bruce B nuclear station, in fall of 1999. The automated ultrasonic phased array technology is capable of high-speed rate and reliable detection and sizing. The capability demonstration was performed on mock-ups and reference blocks, using EDM notches. A custom built UT simulation software: Imagine 3D interfaces with SimScan to generates the spreadsheets/charts with target and probe coordinates and ultrasonic path and angles (refracted and skew) to hit the reference target. Examination of L-0 blade and rotor steeple grooves was performed with 2 phased array systems under networking. Data analysis was done in near-real time. ...

2000-07-01

87

Array coil probe: Final report  

Energy Technology Data Exchange (ETDEWEB)

Nuclear steam generator tubes have become flawed in ways that challenge conventional eddy current probes. In response to the shortcomings of conventional probes, array probes have been developed to improve measurement capabilities. However, the commercially available array probes have exhibited several weaknesses that offset the advantages and limit the applications in steam generator inspections. A primary weakness is the relatively high rate of probe failure coupled with the high unit cost for each probe. This can be costly for a utility in the time lost for probe replacement and increased radiation exposure in addition to the probe costs. Other weaknesses which make array probes undesirable for routine use are: poor mechanical and electrical characteristics; difficulty in operation and ...

1987-03-01

88

Process-integrated online monitoring of safety-relevant aluminum airbag pressure vessel components for a combined defect detection and material property determination by using contactless NDT (EMUS and EC)  

Energy Technology Data Exchange (ETDEWEB)

Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements are used for surface breaking extrusion defect detection and sizing (single ...

1999-07-01

89

Microscopic properties of passive films on Ti and Zr from optical, electrochemical and SXM-measurements  

International Nuclear Information System (INIS)

A combined application of several microtechniques is presented and discussed with the Ti/TiO_2 and Zr/ZrO_2-systems as an example. All measurements were carried out on single grains of technical materials in order to detect and quantify the effect of substrate microstructure on the properties of anodic passive films formed potentiodynamically in 0.5 M H_2SO_4 (dU/dt = 20 mVs"-"1). Anisotropy-micro-ellipsometry (AME) was employed to determine the crystallographic orientation of the substrate grains along with passive film thickness and crystallinity in dependence on the anodization potential. Both the isotropic (amorphous) TiO_2- and the anisotropic (crystalline) ZrO_2-films exhibit a systematic dependence of film thickness on the grain orientation. Local LASER-scanning photocurrent measurements (#lambda#=257 nm) on the same grains likewise show a heterogeneity of the photoelectrochemical reactivity in all cases. This is quantitatively explained by the results from ...

1998-03-01

90

The development of multiple probe microdialysis sampling in the stomach  

UK PubMed Central (United Kingdom)

A multiple probe approach of implanting microdialysis probes into each separate tissue layer would better represent sampling from the stomach. Presently, microdialysis sampling experiments are...Full Text Available

2008-09-10

91

Structure and Crystallization Behavior of Nylong 66/Multi-Walled Carbon Nanotube Nanocomposites at Low Carbon Nanotube Contents  

Energy Technology Data Exchange (ETDEWEB)

Multi-walled carbon nanotubes (MWNTs) were modified with poly(hexamethylene adipamide) (also known as Nylon 66) via a controlled polymer solution crystallization method. A 'nanohybrid shish kebab' (NHSK) structure was found wherein the MWNT resembled the shish while Nylon 66 lamellar crystals formed the kebabs. These Nylon 66-functionalized MWNTs were used as precursors to prepare polymer/MWNT nanocomposites. Excellent dispersion was revealed by optical and electron microscopies. Nitric acid etching of the nanocomposites showed that MWNT formed a robust network in Nylon 66. Non-isothermal DSC results showed multiple melting peaks, which can be attributed to lamellar thickness changes upon heating. The crystallite sizes L{sub 100} and L{sup 010} of Nylon 66, determined by WAXD, decreased with increasing MWNT contents. Isothermal DSC results showed that crystallization kinetics increased first and then decreased with increasing MWNT contents in ...

2007-01-01

92

Separation of Minor Actinides and Lanthanides with Carbon Nano-materials  

Energy Technology Data Exchange (ETDEWEB)

Recently we have found that carbon nano-materials have ability to recognize softer actinides(III). In this presentation, separation of americium(III) from lanthanides(III) by chromatography with carbon nano-materials, such as carbon nano-tubes and graphite, has been investigated by batch adsorption experiments and chromatography. The separation factor (SF) between americium(III) and lanthanide(III) was about 2 in the range of pH from 1 to 4 by using carbon nano-tube, graphite and activated charcoal. The separation factor depended on the diameter of carbon nano-tubes. Smaller one, 3-20 nm diameter, showed the best selectivity for americium(III), which separation factor was about 2.0, although larger one, 40-70 nm, showed almost no selectivity. The same behavior has been observed by using graphite powder and activated charcoal although acid- or alkali pretreated activated charcoal which generally has acidic functional group ...

2009-06-15

93

Functionalized multi-walled carbon nanotubes as affinity ligands  

Energy Technology Data Exchange (ETDEWEB)

Functionalization of carbon nanotubes is very challenging for their applications. The paper here describes a new method to functionalize multi-walled carbon nanotubes (MWCNTs) as specific affinity adsorbents. MWCNTs were acid purified and pretreated with (3-aminopropyl)-triethoxysilane (APTES) in order to introduce abundant amino groups on the surface of MWCNTs. After the conversion of amino groups to carboxyl groups by succinic acid anhydride, MWCNTs were attached to protein A or aminodextran using 1-ethyl-3,3' (dimethylamion)-propylcarbodiimide as a biofunctional crosslinker. The incorporation of aminodextran as a spacer arm noticeably increased the binding capacity of the APTES-modified MWCNTs for protein A. The application of affinity MWCNTs for purification of immunoglobulin G was then evaluated. The affinity of MWCNTs with AMD spacer exhibited a high adsorption capacity of {approx}361 {mu}g IgG/mg MWCNT (wet basis). About 75% of ...

2007-03-21

94

Characterizing Differential Air-Core Eddy Current Probes  

Science.gov (United States)

... Accession Number : ADD331250. Title : Characterizing Differential Air-Core Eddy Current Probes. Corporate Author : Personal ...

98

Vertically aligned carbon nanotube electrodes for lithium-ion batteries  

British Library Electronic Table of Contents (United Kingdom)

As portable electronics become more advanced and alternative energy demands become more prevalent, the development of advanced energy storage technologies is becoming ever more critical in today's society. In order to develop higher power and energy density batteries, innovative electrode materials that provide increased storage capacity, greater rate capabilities, and good cyclability must be developed. Nanostructured materials are gaining increased attention because of their potential to mitigate current electrode limitations. Here we report on the use of vertically aligned multi-walled carbon nanotubes (VA-MWNTs) as the active electrode material in lithium-ion batteries. At low specific currents, these VA-MWNTs have shown high reversible specific capacities (up to 782mAhg^-^1 at 57mAg^-...

2011-01-01

99

Use of Multiwalled Carbon Nanotubes as a SPE Adsorbent for Analysis of Carfentrazone-Ethyl in Water  

British Library Electronic Table of Contents (United Kingdom)

Solid-phase extraction and gas chromatography with electron-capture detection has been used for sensitive, simple, and reliable analysis of carfentrazone-ethyl residues in water. Carfentrazone-ethyl was enriched by use of multiwalled carbon nanotubes (MWCNT), a new adsorptive material. Several conditions affecting recovery of the analyte, for example polarity and volume of eluents, pH of water samples, and sample volume, were studied. Recovery from fortified samples, linear range, and limit of detection were evaluated. The results showed that MWCNT are an efficient SPE adsorbent for preconcentration of carfentrazone-ethyl in water. Under the optimized SPE conditions, recovery of carfentrazone-ethyl from fortified water was 81.49?91.08%, with RSD from 1.66 to 8.21%. The limits of detection ...

2009-01-01

100

Tris(2,2prime-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films  

British Library Electronic Table of Contents (United Kingdom)

A highly sensitive and stable tris(2,2prime-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)32+ immobilized in the ECL sensor by adsorption of Ru(bpy)32+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-...

2006-01-01

101

Tris(2,2prime-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Platinized Carbon Nanotube-Zirconia-Nafion Composite Films  

British Library Electronic Table of Contents (United Kingdom)

Mesoporous films of platinized carbon nanotube-zirconia-Nafion composite have been used for the immobilization of tris(2,2prime-bipyridyl)ruthenium (II) (Ru(bpy)32+) on an electrode surface to yield a solid-state electrogenerated chemiluminescence (ECL) sensor. The composite films of Pt-CNT-zirconia-Nafion exhibit much larger pore diameter (3.55 nm) than that of Nafion (2.82 nm) and thus leading to much larger ECL response for tripropylamine (TPA) because of the fast diffusion of the analyte within the films. Due to the conducting and electrocatalytic features of CNTs and Pt nanoparticles, their incorporation into the zirconia-Nafion composite films resulted in the decreased electron transfer resistance within the films. The present ECL sensor based on the Pt-CNT-zirconia-Nafion gave a lin...

2010-01-01

102

Torsional responses of double-walled carbon nanotubes via molecular dynamics simulations  

Energy Technology Data Exchange (ETDEWEB)

The buckling behaviors of double-walled carbon nanotubes (DWCNTs) under torsion are investigated by using molecular dynamics (MD) simulations. The effect of length on the torsional buckling behaviors of DWCNTs is examined for the first time. The simulation results show that the DWCNTs experience gradual or simultaneous buckling deformations depending on their lengths. In addition, the effect of the inner tube in a DWCNT on its torsional buckling behavior is also examined. The presence of the inner tube triggers van der Waals (vdW) interactions between it and the outer tube and thus leads to a stiffening effect of the DWCNT against torsional deformation. Whether the ends of the inner tube are free or fixed and whether it is subject to a torque or not, the critical torque and the critical torsional angle of the outer tube are only marginally affected.

2008-11-12

103

Synthesis and properties of macromer-grafted polymers for noncovalent functionalization of multiwalled carbon nanotubes  

British Library Electronic Table of Contents (United Kingdom)

We prepared macromer-grafted polymers (MGPs) containing suitable polymer side chains for improving solubility and pyrene units for improving adsorption on multiwalled carbon nanotube (MWCNT) surfaces, and demonstrated that these MGPs act as MWCNT solubilizers that improve solubility of MWCNTs in typically poor solvents such as alkanes and that improve flowability of polymer/MWCNT composites. The polydimethylsiloxane (PDMS)-MGPs, synthesized using PDMS macromers and pyrene-containing monomers, improved solubility of MWCNTs not only in chloroform but also in hexane, which is a poor solvent for MWCNTs. Moreover, the addition of PDMS-MGP-adsorbed MWCNTs (MWCNT/PDMS-MGPs) to epoxy resin monomers or polybutylene terephthalate (PBT) drastically reduced the viscosity of the obtained epoxy resin mo...

2009-01-01

104

Pressure-induced structural transitions in multi-walled carbon nanotubes  

British Library Electronic Table of Contents (United Kingdom)

We demonstrate a novel cross-sectional deformation, called the radial corrugation, of multi-walled carbon nanotubes (MWNTs) under hydrostatic pressure. Theoretical analyses based on the continuum elastic approximation have revealed that MWNTs consisting of more than ten concentric walls undergo elastic deformations at critical pressure Formula Not Shown , above which the circular shape of the cross-section becomes radially corrugated. Various corrugation modes have been observed by tuning the innermost tube diameter and the number of constituent walls, which is a direct consequence of the core-shell structure of MWNTs. Cross-sectional views of MWNT under high hydrostatic pressure: elliptic deformation with the mode index n = 2 (left), and radial corrugations with n = 5 (center), and n = 6 ...

2009-01-01

105

Polyester and multiwalled carbon nanotube composites: characterization, electrical conductivity and antibacterial activity  

British Library Electronic Table of Contents (United Kingdom)

Abstract Poly(butylene terephthalate) (PBT) composites containing multiwalled carbon nanotubes (MWCNTs) were prepared using a melt-blending process and used to examine the effects on the composite structure and properties of replacing PBT with acrylic acid-grafted PBT (PBT-g-AA). PBT-g-AA and multihydroxyl-functionalized MWCNTs (MWCNTs-OH) were used to improve the compatibility and dispersibility of the MWCNTs within the PBT matrix. The composites were characterized morphologically using transmission electron microscopy, and chemically using Fourier transform infrared, solid-state 13C NMR and UV-visible absorption spectroscopy. The antibacterial and electrical conductivity properties of the composites were also evaluated. MWCNTs or MWCNTs-OH enhanced the antibacterial activity and electric...

2011-01-01

106

New highly active oxygen reduction electrode for PEM fuel cell and Zn/air battery applications (NORA). Final report  

Energy Technology Data Exchange (ETDEWEB)

This illustrated final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project concerning a new, highly active oxygen reduction electrode for PEM fuel cell and zinc/air battery applications. The goal of this project was, according to the authors, to increase the efficiency of the oxygen reduction reaction by lowering the activation polarisation through the right choice of catalyst and by lowering the concentration polarisation. In this work, carbon nanotubes are used as support material. The use of these nanotubes grown on perovskites is discussed. Theoretical considerations regarding activation polarisation are discussed and alternatives to the use of platinum are examined. The results of experiments carried out are presented in graphical and tabular form. The paper is completed with a comprehensive list of references.

2008-04-15

107

Multi walled carbon nanotubes/epilson polylysine nanocomposite with enhanced antibacterial activity  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aims: To develop a new nano composite of multi walled carbon nanotubes (MWNTs) with enhanced antimicrobial activity. Methods and Results: A novel antimicrobial nanocomposite [MWNT epilson polylysine (MEPs)] was synthesized via covalent attachment of epilson polylysine on MWNTs with hexamethylene diisocyanate (HDI) as the coupling agent. UV visible spectra and Fourier transform infrared spectra (FT IR) investigations indicate that MEPs is stable, with epilson polylysine leaching effectively eliminated. When compared to MWNTs, the new nano composite MEPs exhibits enhanced antimicrobial activities. In 20 mg l 1 suspensions, significant increases of 72 1, 64 5 and 69% against Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus can be observed. The deposited film of MEPs...

2011-01-01

108

Evaluation of the addition of various surfactant-suspended carbon nanotubes in MEEKC with an in situ-synthesized surfactant system  

British Library Electronic Table of Contents (United Kingdom)

Abstract Dispersions of single-walled carbon nanotubes (SWNTs) in various surfactant solutions have been systematically evaluated as additives in MEEKC. The compounds examined were catechins, phenolic acids, and flavonoids. Compared with zwitterionic and neutral surfactants, the addition of anionic dispersion seemed to be better at separating the three types of analytes in microemulsion system. In order to achieve low operating currents, an in situ-synthesized surfactant system based on the combination of a long-chain alkyl acid with an organic base was used in MEEKC. The optimized buffer contained 0.5% (57-mM) ethyl acetate, 0.6% (30-mM) lauric acid, 4.0% (666-mM) propanol, 50-mM Tris solution, and 4.5-mg/L the dispersion of SWNTs. Under optimized conditions, the established method was ap...

2011-01-01

109

Effects of intradot electron-electron interaction on the photon-assisted Andreev tunneling through a finite-sized carbon-nanotube system  

International Nuclear Information System (INIS)

The effects of intradot electron-electron interaction on the photon-assisted Andreev tunneling of a superconductor/carbon-nanotube/superconductor system are studied by using nonequilibrium Green's function technique. The inverse supercurrent reflecting the #pi#-junction transition emerges in the spin-split energy-levels regime polarized by the Coulomb interaction. For the positive tunneling case, the supercurrent reaches its maximum when the spin-degenerate energy-levels are nearest to the Fermi surface. Conversely, for the negative tunneling case, the supercurrent reaches its maximum when two split energy-levels are symmetric with respect of the Fermi surface. The sign and the amplitude of the Andreev tunneling depend distinctly on the energy-level spacing tuned by photon-assisted tunneling. In order to fully understand the transport characteristics, the current-carrying density of states are investigated, which clearly shows the enhancement, suppression or even ...

2007-01-01

110

A computational study of aluminum phosphide nanotubes  

British Library Electronic Table of Contents (United Kingdom)

Abstract Electronic structures of two representative zigzag and armchair models of aluminum phosphide nanotube (AlPNT) were investigated by density functional theory calculations. The structures were optimized and the bond lengths, tip diameters, band gaps, and dipole moments were calculated. Moreover, the quadrupole coupling constants (CQ) were calculated for the Al-27 atoms of the optimized structures. The same values of AlP bond lengths were calculated for both models. The larger value of band gap of armchair model than the zigzag model indicated the stronger dielectric property for the former model. The values of CQ(27Al) were the largest for the Al atoms placed at the tips of both zigzag and armchair AlPNT than other Al atoms, which could reveal dominant role of the Al atoms placed at...

2011-01-01

111

Particle-Sizing System for Scanning Electron Microscope ...  

Science.gov (United States)

... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...

1991-03-01

112

A bright field scanning transmission electron microscope (STEM ...  

Science.gov (United States)

A bright field scanning transmission electron microscope (STEM) micrograph showing a Wassonite grain in dark contrast. ...

113

Transmit-receive eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).

1987-09-01

115

Probing Neutron Star Evolution with Gamma Rays  

Science.gov (United States)

The research sponsored by this grant was conducted in two fields of high-energy astrophysics:

1996-01-01

116

Optic probe for semiconductor characterization  

Energy Technology Data Exchange (ETDEWEB)

Described herein is an optical probe (120) for use in characterizing surface defects in wafers, such as semiconductor wafers. The optical probe (120) detects laser light reflected from the surface (124) of the wafer (106) within various ranges of angles. Characteristics of defects in the surface (124) of the wafer (106) are determined based on the amount of reflected laser light detected in each of the ranges of angles. Additionally, a wafer characterization system (100) is described that includes the described optical probe (120).

2008-09-02

120

Device for the inspection of curved pipes in steam raising units  

Energy Technology Data Exchange (ETDEWEB)

The chain of eddy current probes and a film cassette probe, which responds to radiation from a radio-active source in one of the heat exchanger pipes is examined. The probes are moved by nylon pipes on both ends of the chain through the pipe to be examined. The nylon pipes are bent off load. In this way the probes on the chain will adjust near to the plane of bending of the pipes to be tested.

1980-01-03

121

Rotational modes of oscillation of rodlike dust grains in a plasma  

CERN Document Server

Three dimensional rotatory modes of oscillations in a one-dimensional chain of rodlike charged particles or dust grains in a plasma are investigated. The dispersion characteristics of the modes are analyzed. The stability of different equilibrium orientations of the rods, phase transitions between the different equilibria, and a critical dependence on the relative strength of the confining potential are analyzed. The relations of these processes with liquid crystals, nanotubing, and plasma coating are discussed.

2003-01-01

122

Nanocomposite electrodes based on pre-synthesized organically capped platinum nanoparticles and carbon nanotubes. Part I: Tuneable low platinum loadings, specific H upd feature and evidence for oxygen reduction  

Energy Technology Data Exchange (ETDEWEB)

A bottom-up approach is used here to combine carbon nanotubes synthesized by CVD and organically capped platinum nanoparticles electrocatalyst exhibiting a direct electrochemical activity towards oxygen reduction. Both nano-objects are handled in liquid suspension and are associated together in a controlled way. The nanocomposite liquid dispersions can be precisely controlled in terms of platinum nanoparticles to carbon nanotubes weight ratios (NP/NT) which correspond to different coverages of nanotubes by nanoparticles. Electrodes with low to ultra-low platinum loadings can then be prepared on porous fuel cell carbon supports by filtration. The direct electrochemical activity towards aqueous oxygen reduction reaction (ORR) of electrodes with platinum loadings ranging from about 1 to 60 {mu}g/cm{sup 2} is reported without any activation step in order to keep the features of the nanoparticles intact. Before that, we studied ...

2009-09-30

123

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

124

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating ...

2009-04-15

125

Computer modelling of eddy current probes  

International Nuclear Information System (INIS)

Computer programs have been developed for modelling impedance and transmit-receive eddy current probes in two-dimensional axis-symmetric configurations. These programs, which are based on analytic equations, simulate bobbin probes in infinitely long tubes and surface probes on plates. They calculate probe signal due to uniform variations in conductor thickness, resistivity and permeability. These signals depend on probe design and frequency. A finite element numerical program has been procured to calculate magnetic permeability in non-linear ferromagnetic materials. Permeability values from these calculations can be incorporated into the above analytic programs to predict signals from eddy current probes with permanent magnets in ferromagnetic tubes. These programs were used to test various probe designs for new testing applications. ...

1992-10-01

126

Surfactant based sol-gel approach to nanostructured LiFePO{sub 4} for high rate Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

Porous nanostructured LiFePO{sub 4} powder with a narrow particle size distribution (100-300nm) for high rate lithium-ion battery cathode application was obtained using an ethanol based sol-gel route employing lauric acid as a surfactant. The synthesized LiFePO{sub 4} powders comprised of agglomerates of crystallites <65nm in diameter exhibiting a specific surface area ranging from 8m{sup 2}g{sup -1} to 36m{sup 2}g{sup -1} depending on the absence or presence of the surfactant. The LiFePO{sub 4} obtained using lauric acid resulted in a specific capacity of 123mAhg{sup -1} and 157mAhg{sup -1} at discharge rates of 10C and 1C with less than 0.08% fade per cycle, respectively. Structural and microstructural characterization were performed using X-ray diffraction (XRD), scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM) with energy dispersive X-ray (EDX) analysis while electronic conductivity and specific surface area ...

2007-01-01

127

STM studies of CDWs in pure and doped transition metal chalcogenides  

Energy Technology Data Exchange (ETDEWEB)

The effects of dilute impurity doping on charge-density wave (CDW) structures and gaps in NbSe{sub 3} 1T-TaS{sub 2} and 2H-NbSe{sub 2} have been studied by using a scanning tunneling microscope (STM) operating at 4.2 K. In Fe doped samples of NbSe{sub 3} the STM spectroscopy measurements indicate that the added impurities can significantly shift the CDW energy gaps. In NbSe{sub 3}, Fe reduces both CDW gaps by 25-30%, and produces changes in the conductance structure relative to the pure material. The images of Fe{sub 0.01}NbSe{sub 3} show that all three surface chains in the unit cell still carry a strong CDW modulation with no evident disorder. However, a change in the relative amplitudes of the high and low temperature CDWs is detected. The effects of Co and Ni impurities on the gaps in NbSe{sub 3} have also been studied. While Co increases both by 25-30%, Ni increases only the high temperature gap with the low temperature gap remaining essentially unchanged. In ...

1992-12-01

128

Performance of a high Cr and Ni austenitic stainless steel plates in PEMFC working environments  

Energy Technology Data Exchange (ETDEWEB)

The high cost of proton exchange membrane fuel cells (PEMFCs) poses a significant challenges to their commercial uptake. The bipolar plates connect the anode and cathodes of cells and separate the reactant gases, and are the most expensive components in PEMFCs. Although stainless steel can be used as a low-cost alternative in bipolar plate construction, steel is prone to electrochemical corrosion in the highly acidic PEMFC operation process. This study examined the polarization curves and ICR as a function of compaction force of a high Cr and Ni austenitic stainless steel in an environment simulating the bipolar plate under PEMFC operating conditions. The 3-electrode system consisted of a platinum (Pt) sheet, a saturated calomel electrode with a Luggin capillary contract with the used solution and the work electrode. All polarization curves were measured in a solution of H{sub 2}SO{sub 4} in order to simulate the aggressive PEMFC environment. Surface morphologies of the steels were ...

2006-07-01

129

Neutrino fluxes from constrained minimal supersymmetric standard model lightest supersymmetric particle annihilations in the Sun  

International Nuclear Information System (INIS)

We evaluate the neutrino fluxes to be expected from neutralino lightest supersymmetric particle (LSP) annihilations inside the Sun, within the minimal supersymmetric extension of the standard model with supersymmetry-breaking scalar and gaugino masses constrained to be universal at the grand unified theory scale [the constrained minimal supersymmetric standard model (CMSSM)]. We find that there are large regions of typical CMSSM (m_1_/_2,m_0) planes where the LSP density inside the Sun is not in equilibrium, so that the annihilation rate may be far below the capture rate. We show that neutrino fluxes are dependent on the solar model at the 20% level, and adopt the AGSS09 model of Serenelli et al. for our detailed studies. We find that there are large regions of the CMSSM (m_1_/_2,m_0) planes where the capture rate is not dominated by spin-dependent LSP-proton scattering, e.g., at large m_1_/_2 along the CMSSM coannihilation strip. We calculate neutrino fluxes above various threshold ...

2010-04-15

130

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe Microanalysis), AES (Auger Electron Spectroscopy) and XPS (X-ray Photoelectron ...

1999-07-15

131

In situ spectroscopic and corrosion studies of ultra-thin gradient plasma polymer layers on zinc  

International Nuclear Information System (INIS)

By means of an audio frequency plasma polymerisation ultra-thin gradient plasma polymer layers were deposited on zinc and zinc-coated iron. The aim was to generate an interfacial polymeric layer which bonds to an oxidised metal as well as to a subsequently applied organic coating and acts as an interfacial barrier layer for ions and water. Surface modifications were done in an in situ plasma cell with infrared reflection absorption spectroscopy (IRRAS). The zinc surface was first activated by an oxygen plasma to provide a freshly oxidised and contamination free oxide surface. The intermediate stages of the surface reactions could be revealed. Carbon dioxide molecules as oxidation products adsorbed on the growing zinc oxide and were desorbed at a later stage. An organosilicon plasma polymer was deposited directly on top of the oxide layer from a hexamethyldisilane (HMDS) plasma. Afterwards a cyclohexene (CHEX)/hexamethyldisilane co-plasma polymer was deposited. The top plasma polymer ...

2003-07-15

132

Characterization of aluminum surfaces: Sorption and etching  

Science.gov (United States)

Aluminum, due to its low density and low cost, is a key material for future lightweight applications. However, like other structural materials, aluminum is subject to various forms of corrosion damage that annually costs the United States approximately 5% of its GNP [1]. The main goal is to investigate the effects of various solution anions on aluminum surfaces, and specifically probe pit initiation and inhibition. Using surface analysis techniques including X-ray photoelectron spectroscopy, Auger electron spectroscopy, and scanning electron microscopy, results have been correlated with those obtained from electrochemical methods and a radiolabeling technique developed in the Wieckowski laboratory. Analysis of data has indicated that important variables include type of anion, solution pH, and applied electrode potential. While aggressive anions such as chloride are usually studied to elucidate corrosion processes to work ultimately toward ...

2001-01-01

133

#omega#-Assisted nucleation and growth of #alpha# precipitates in the Ti-5Al-5Mo-5V-3Cr-0.5Fe #beta# titanium alloy  

International Nuclear Information System (INIS)

This paper discusses the structural and compositional changes at the nanometer scale associated with the nucleation and growth of #alpha# precipitates in the #beta# titanium alloy Ti-5553 (Ti-5Al-5Mo-5 V-3Cr-0.5Fe) with #omega# precipitates acting as heterogeneous nucleation sites. The microstructural evolution in this alloy, during #beta#-solutionizing, quenching and aging type heat-treatments, has been investigated by combining results from scanning electron microscopy, orientation imaging microscopy, transmission electron microscopy, high-resolution TEM and three-dimensional atom probe (3DAP) tomography. Athermal #omega# precipitates form in this alloy on quenching from above the #beta# transus temperature. On isothermal annealing at low temperatures, these #omega# precipitates coarsen to form chemically ordered #omega# precipitates, accompanied by the nucleation of the stable #alpha# phase. Annealing at higher temperatures leads to ...

2009-04-01

134

Evaluation of surgical gamma probes for sentinel node localisation in cervical and vulvar cancer  

International Nuclear Information System (INIS)

Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be considered in the appropriate selection of ...

135

Motion compensation with a scanned ion beam: a technical feasibility study  

UK PubMed Central (United Kingdom)

BackgroundIntrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target...Full Text Available

137

Bone scanning in Ewing's sarcoma  

International Nuclear Information System (INIS)

In eight patients with Ewing's sarcoma bone scans were performed using "9"9"mTc-MDP. This procedure rendered possible the diagnosis of clinically or radiologically silent metastases. (orig.).

138

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples  

Science.gov (United States)

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to

2003-01-01

139

chipD: a web tool to design oligonucleotide probes for high-density tiling arrays  

UK PubMed Central (United Kingdom)

chipD is a web server that facilitates design of DNA oligonucleotide probes for high-density tiling arrays, which can be used in a number of genomic applications such as ChIP-chip or gene-expression...Full Text Available

2010-07-01

140

Use of synthetic oligoribonucleotides to probe RNA-protein interactions in the MS2 translational operator complex.  

UK PubMed Central (United Kingdom)

Synthetic oligoribonucleotides have been used to probe the interaction of MS2 coat protein with the translational operator of the MS2 replicase gene. We have investigated the possible formation of a...Full Text Available

1990-06-25

141

Use of synthetic oligonucleotide DNA probes for identification and direct detection of Bacteroides forsythus in plaque samples.  

UK PubMed Central (United Kingdom)

Oligonucleotide DNA probes complementary to the hypervariable region of the 16S rRNA of Bacteroides forsythus were tested for their specificity and sensitivity against reference and clinical isolates...Full Text Available

1991-10-01

142

Use of an alkaline phosphatase-labeled synthetic oligonucleotide probe for detection of Campylobacter jejuni and Campylobacter coli.  

UK PubMed Central (United Kingdom)

A commercially available synthetic nucleic acid probe (SNAP) conjugated to alkaline phosphatase was compared with standard culture techniques for detecting Campylobacter species. The SNAP was able to...Full Text Available

1990-07-01

143

Rapid aneuploidy detection with multiplex ligation-dependent probe amplification: a prospective study of 4000 amniotic fluid samples  

UK PubMed Central (United Kingdom)

The introduction of prenatal screening requires rapid high-throughput diagnosis of common aneuploidies. Multiplex ligation-dependent probe amplification (MLPA) allows for quick, easily automated multiplex...Full Text Available

2009-01-01

144

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

145

Improved eddy-current inspection for steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generator test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking and IGA. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe ...

1989-01-01

146

Electrostatic probe vacuum system for TCA BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)

1999-12-01

147

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

148

Detection and Analysis of Tumor Fluorescence Using a Two-Photon Optical Fiber Probe  

UK PubMed Central (United Kingdom)

The utility of a two-photon optical fiber fluorescence probe (TPOFF) for sensing and quantifying tumor fluorescent signals was tested in vivo. Xenograft tumors were developed in athymic mice using MCA207...Full Text Available

2004-06-01

149

5-Fluorodeoxyuridine as an alternative to the synthesis of mixed hybridization probes for the detection of specific gene sequences.  

UK PubMed Central (United Kingdom)

Synthetic complementary oligonucleotides are useful hybridization probes for the detection of mRNAs and genes encoding proteins for which only a partial amino acid sequence is known. Usually this involves...Full Text Available

1988-03-01

150

Synchrotron Probes of Emergent Electronic States of Matter in Solids  

ScienceCinema

...of this article he quotes um i am told by my english ...

151

Some Properties of Australian Produced Explosive ...  

Science.gov (United States)

... The rounds were initiated by an exploding bridgewire detonator (EBW) and the ionisation probes were progressively cloud by the detonation front. ...

1987-10-01

152

Signal simulator for the calibration of eddy current probes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.

1994-01-01

154

EFFECTS OF SHIELDING ON PROPERTIES OF EDDY ...  

Science.gov (United States)

... Accession Number : ADD323869. Title : EFFECTS OF SHIELDING ON PROPERTIES OF EDDY CURRENT PROBES WITH FERRITE CUP CORES. ...

1986-08-01

155

EDDY CURRENT SIZING OF CASE DEPTH IN BEARING ...  

Science.gov (United States)

... HARDENED CUP AND CARBURIZED AND HARDENED CORES HAVE BEEN PROFILED USING 2 TYPES OF EDDY CURRENT PROBES. ...

1986-07-01

156

Spark plasma sintered tantalum carbide-carbon nanotube composite: Effect of pressure, carbon nanotube length and dispersion technique on microstructure and mechanical properties  

British Library Electronic Table of Contents (United Kingdom)

TaC-4wt.% CNT composites were synthesized using spark plasma sintering. Two kinds of CNTs, having long (10-20mm) and short (1-3mm) length, were dispersed by wet chemistry and spray drying techniques respectively. Spark plasma sintering was carried out at 1850^oC at pressures of 100, 255 and 363MPa. Addition of CNTs leads to an increase in the density of 100MPa sample from 89% to 95%. Short CNTs are more effective in increasing the density of the composites whereas long CNTs are more effective grain growth inhibitors. The longer CNTs are more effective in increasing the fracture toughness and an increase up to 60% was observed for 363MPa sample. Hardness and elastic modulus are found to increase by 22% and 18% respectively for 100MPa samples by addition of long CNTs. Raman spectroscopy, SEM...

2011-01-01

157

Silver nanoparticle-decorated carbon nanotubes as bifunctional gas-diffusion electrodes for zinc-air batteries  

Energy Technology Data Exchange (ETDEWEB)

Thin, lightweight, and flexible gas-diffusion electrodes (GDEs) based on freestanding entangled networks of single-walled carbon nanotubes (SWNTs) decorated with Ag nanoparticles (AgNPs) are tested as the air-breathing cathode in a zinc-air battery. The SWNT networks provide a highly porous surface for active oxygen absorption and diffusion. The high conductivity of SWNTs coupled with the catalytic activity of AgNPs for oxygen reduction leads to an improvement in the performance of the zinc-air cell. By modulating the pH value and the reaction time, different sizes of AgNPs are decorated uniformly on the SWNTs, as revealed by transmission electron microscopy and powder X-ray diffraction. AgNPs with sizes of 3-5 nm double the capacity and specific energy of a zinc-air battery as compared with bare SWNTs. The simplified, lightweight architecture shows significant advantages over conventional carbon-based GDEs in terms of weight, thickness and conductivity, and hence ...

2010-07-01

158

Sensitive detection of endocrine disrupters using ionic liquid - Single walled carbon nanotubes modified screen-printed based biosensors.  

Science.gov (United States)

Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF(6)]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT-[BMIM][PF(6)] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of -0.2V vs. Ag/AgCl, in linear range from 5.5 to 97.7?M for 4-t-octylphenol and respectively, between 5.5 and 140?M for 4-n-nonylphenol, with a response time of about 5s. The detection limit was 1.1?M for 4-t-octylphenol, and respectively 0.4?M for 4-n-nonylphenol (S/N=3). ...

2011-07-19

159

Mechanical Properties of Bamboo-like Boron Nitride Nanotubes by In Situ TEM and MD Simulations: Strengthening Effect of Interlocked Joint Interfaces.  

Science.gov (United States)

Understanding the influence of interfacial structures on the nanoarchitecture mechanical properties is of particular importance for its mechanical applications. Due to a small size of constituting nanostructural units and a consequently high volume ratio of such interfacial regions, this question becomes crucial for the overall mechanical performance. Boron nitride bamboo-like nanotubes, called hereafter boron nitride nanobamboos (BNNBs), are composed of short BN nanotubular segments with specific interfaces at the bamboo-shaped joints. In this work, the mechanical properties of such structures are investigated by using direct in situ transmission electron microscopy tensile tests and molecular dynamics simulations. The mechanical properties and deformation behaviors are correlated with the interfacial structure under atomic resolution, and a geometry strengthening effect is clearly demonstrated. Due to the interlocked joint interfacial structures and compressive ...

2011-08-10

160

Characterization of hydrophobic ionic liquid-carbon nanotubes-gold nanoparticles composite film coated electrode and the simultaneous voltammetric determination of guanine and adenine  

Energy Technology Data Exchange (ETDEWEB)

A novel composite film, comprising of hydrophobic ionic liquid (IL), multi-walled carbon nanotubes (MWNTs) and gold nanoparticles (GNP), was fabricated and characterized. The GNP was introduced through electrochemical deposition on IL-MWNT gel film coated glassy carbon electrodes (GCE). Experiments showed that both IL and MWNTs could facilitate the GNP deposition. With GNP the composite film exhibited smaller electron transfer resistance and higher sensitivity in sensing guanine (G) and adenine (A). Under the optimized experimental conditions, the anodic peak currents were linear to the analyte concentration in the ranges of 0.008-2.0 {mu}M. The detection limits were down to nanomole level after an accumulation of 150 s on open-circuit. In addition, on the composite film coated GCE, the anodic peaks of G and A were well separated, and their response sensitivities kept almost unchanged no matter whether they coexisted or not. This proposed procedure was successfully ...

2008-11-01

161

Characterization of hydrophobic ionic liquid-carbon nanotubes-gold nanoparticles composite film coated electrode and the simultaneous voltammetric determination of guanine and adenine  

International Nuclear Information System (INIS)

A novel composite film, comprising of hydrophobic ionic liquid (IL), multi-walled carbon nanotubes (MWNTs) and gold nanoparticles (GNP), was fabricated and characterized. The GNP was introduced through electrochemical deposition on IL-MWNT gel film coated glassy carbon electrodes (GCE). Experiments showed that both IL and MWNTs could facilitate the GNP deposition. With GNP the composite film exhibited smaller electron transfer resistance and higher sensitivity in sensing guanine (G) and adenine (A). Under the optimized experimental conditions, the anodic peak currents were linear to the analyte concentration in the ranges of 0.008-2.0 ?M. The detection limits were down to nanomole level after an accumulation of 150 s on open-circuit. In addition, on the composite film coated GCE, the anodic peaks of G and A were well separated, and their response sensitivities kept almost unchanged no matter whether they coexisted or not. This proposed procedure was successfully ...

2008-11-01

162

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

163

Evaluation of phased array UT conditions using ultrasonic visualization technique  

International Nuclear Information System (INIS)

Phased array provides many advantages over conventional ultrasonic testing method, but phased array has also limitations. This paper describes typical results of the experimental sound field analysis generated from the array probe. A photo-elastic ultrasonic visualization technique was applied in this study. The sound fields of shear wave generated from the array probe was equivalent to that from the fixed angle probe. (author)

2008-07-01

164

Array coil probe design optimization  

International Nuclear Information System (INIS)

To overcome the limitations of conventional bobbin style eddy-current probes, it has become common practice to perform some portion of a steam generator tube inspection program with array coil probes. Typically, eight surface-riding pancake coils are utilized in a probe head, either as eight independent coils (8 x 1) or in a parallel combination of four serially connected coils (4 x 4). The advantages of the array coils are improved sensitivity to intergranular attack (IGA), reduced interference from tube denting, and improved sensitivity to circumferential cracking. The current status of commercially available probes is such that several weaknesses in array coils have limited the widespread application of this technology. Task S 301-6 was conceived to address each of the weaknesses in order to produce a more reliable and cost-effective probe. The emphasis was on reliability, since ...

1987-07-01

165

Electrocatalytic oxidation of deferiprone and its determination on a carbon nanotube-modified glassy carbon electrode  

Energy Technology Data Exchange (ETDEWEB)

The electrochemical behavior of the anti-thalassemia and anti-HIV replication drug, deferiprone, was investigated on a carbon nanotube-modified glassy carbon (GC-CNT) electrode in phosphate buffer solution, pH 7.40 (PBS). During oxidation of deferiprone, two irreversible anodic peaks, with E{sub 1}{sup 0}=452 and E{sub 2}{sup 0}=906mV, appeared, using GC-CNT. Cyclic voltammetric study indicated that the oxidation process is irreversible and diffusion controlled. The number of exchanged electrons in the electro-oxidation process was obtained, and the data indicated that deferiprone is oxidized via two two-electron steps. The results revealed that carbon nanotube (CNT) promotes the rate of oxidation by increasing the peak current, so that deferiprone is oxidized at lower potentials, which thermodynamically is more favorable. This result was confirmed by impedance measurements. The diffusion coefficient, electron-transfer coefficient and ...

2008-02-15

166

Biomimetic helical rosette nanotubes and nanocrystalline hydroxyapatite coatings on titanium for improving orthopedic implants  

Science.gov (United States)

Natural bone consists of hard nanostructured hydroxyapatite (HA) in a nanostructured protein-based soft hydrogel template (ie, mostly collagen). For this reason, nanostructured HA has been an intriguing coating material on traditionally used titanium for improving orthopedic applications. In addition, helical rosette nanotubes (HRNs), newly developed materials which form through the self-assembly process of DNA base pair building blocks in body solutions, are soft nanotubes with a helical architecture that mimics natural collagen. Thus, the objective of this in vitro study was for the first time to combine the promising attributes of HRNs and nanocrystalline HA on titanium and assess osteoblast (bone-forming cell) functions. Different sizes of nanocrystalline HA were synthesized in this study through a wet chemical precipitation process following either hydrothermal treatment or sintering. Transmission electron microscopy images showed that ...

2008-01-01

167

Versatile gamma scanning system  

International Nuclear Information System (INIS)

(Feb 1972). United States Swinth, KL Weber, JW San Francisco, Calif.

171

Is there still a place for bone scanning in Ewing's sarcoma: concise communication  

International Nuclear Information System (INIS)

In this retrospective study, 28 cases of Ewing's sarcoma are reviewed for the onset of metastasis. Bone scans demonstrated bone metastasis in three out of 28 patients at presentation. Of the 22 patients free of metastases at presentation, ten subsequently developed bone metastases. In six of these patients, the bone scan was the earliest demonstrator of metastatic disease. Bone scans are recommended at presentation and periodically during follow-up.

174

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

176

Special eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heat exchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes ...

1986-11-17

177

Mathematical modeling of x-probe eddy current array coils used in tube inspection  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model that calculates eddy current signals from laterally spaced transmit-receive pancake coils. This model was validated by comparing calculations with laboratory measurements and it has been applied to evaluating design variations in X-Probe eddy current array coils. This model was used to quantify detection capabilities of probe designs with different numbers of coils. The current standard X-Probe design for 13 mm (0.5 inch) diameter steam generator tubes uses 3 rows of coils with 8 coils per row. This design is commonly referred to as the '8 coil X-Probe'. A significant improvement in detection capability was predicted for an X-Probe with 12 coils per row (called the '12 coil X-Probe') detecting short circumferential crack-like flaws. Based on these calculations, a prototype 12 coil ...

2004-11-15

178

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

Energy Technology Data Exchange (ETDEWEB)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for ...

2010-05-15

179

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

International Nuclear Information System (INIS)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for ...

2010-05-01

180

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. ...

1979-01-01

181

Performance evaluation of corrosion probes in simulated WVNS tank 8D-2 waste: WVNS tank farm process support  

Energy Technology Data Exchange (ETDEWEB)

Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at {approximately}150{degrees}F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ``time-averaged`` value of the corrosion rate. The other approach uses a shorter period of time (relative to the length of the ...

1994-07-01

182

Improvement of detectability for circumferential crack of Steam Generator tube by eddy current and ultrasonic testing method  

International Nuclear Information System (INIS)

Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to ...

1991-08-01

183

Design of the electromagnetic fluctuations diagnostic for MFTF-B  

Energy Technology Data Exchange (ETDEWEB)

The Electromagnetic Fluctuations (EMF) diagnostic will be used to monitor ion fluctuations which could be unstable in MFTF-B. Each probe assembly includes a high impedance electrostatic probe to measure potential fluctuations, and a group of nested, single turn loops to measure magnetic fluctuations in three directions. Eventually, more probes and loops will be added to each probe assembly for making more detailed measurements. The sensors must lie physically close to the plasma edge and are radially positionable. Also, probes at separate axial locations can be positioned to connect along the same magnetic field line. These probes are similar in concept to the rf probes used on TMX, but the high thermal load for 30-second shots on MFTF-B requires a water-cooled design along with temperature monitors. Each signal channel has a bandwidth of ...

1983-11-28

184

Transmit-receive eddy current probes  

International Nuclear Information System (INIS)

In the last two decades, due to increased inspection demands, eddy current instrumentation has advanced from single-frequency, single-output instruments to multifrequency, computer-aided systems. This has significantly increased the scope of eddy current testing, but, unfortunately, it has also increased the cost and complexity of inspections. In addition, this approach has not always improved defect detectability or signal-to-noise. Most eddy current testing applications are still performed with impedance probes, which have well known limitations. However, recent research at AECL has led to improved eddy current inspections through the design and development of transmit-receive (T/R) probes. T/R eddy current probes, with laterally displaced transmit and receive coils, present a number of advantages over impedance probes. They have improved signal-to-noise ratio in the presence of variable lift-off ...

1997-10-27

185

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules ...

2006-04-01

186

"9"9"mTechnetium-heat damaged erythrocyte spleen scan  

International Nuclear Information System (INIS)

"9"9"mTechnetium -heat damaged erythrocyte were used as spleen scanning agents in 12 patients from July, 1985 to April, 1986. We used this scan to evaluate situs inversus, asplenia, accessory spleen, hypersplenism, splenic infarction, tumor staging and evaluation of therapy, especially when the "9"9"mTc-tin colloid scans were not definite for diagnosis. The techniques applied to these scans were in vivo/in vitro-labeling method and heating-method to damage the erythrocytes. Liver-to-spleen uptake ratios were increased upto 100:1 and interference from the left lobe of the liver was eliminated. These scans were helpful to evaluate the spleen. (Author).

187

Experimental studies on a structure of eddy current probe for detection of magnetic flux disturbed by a flaw  

International Nuclear Information System (INIS)

Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. Nondestructive flaw detection tests was ...

1995-01-01

188

Understanding the operation and use of high temperature electrochemical corrosion rate probes  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical corrosion rate probes were constructed and tested along with mass loss coupons in a N2/O2/CO2 plus water vapor environment. Temperatures ranged from 450 to 600 C. Corrosion rates for ash-covered mild steel, 304L SS, and 316L SS probes using electrochemical techniques were a function of time, temperature, and process environment. Correlation between electrochemical and mass loss corrosion rates was good.

2004-01-01

189

The electron current to a Langmuir Probe in a flowing high-pressure plasma  

International Nuclear Information System (INIS)

This paper reports on the electron current to a Langmuir probe in a moving high-pressure plasma. The plasma is an atmospheric-pressure propane flame, and the probe's speed relative to the plasma is varied from 10 to 30 ms"-"1. The current is linearly dependent on the speed and appears to be comprised of two components - one driven by diffusion and the other by convection. A model is devised which can be used to measure the electron density. By comparing the density computed from this model to that measured from the ion current, it has been possible to measure the electron mobility in the flame gases. The value obtained here is in good agreement with theoretical calculations found in the literature.

190

Finite element prediction of differential eddy current probe signals from Fe _30_4 deposits in PWR steam generators  

International Nuclear Information System (INIS)

The paper is concerned with the simulation of practical testing situations which are too difficult and/or expensive to replicate in a laboratory environment. Numerical experiments are described which simulate the differential eddy current probe response to the build-up and chemical flushing of magnetite in the crevice gap of a PWR steam generator unit. The simulation results agree well with the only experimental data available to the authors and lead to the conclusion that conventional differential eddy current probes should be capable of characterizing crevice gap conditions with respect to the presence of magnetite. (author).

1985-01-01

191

D-brane probe and closed string tachyons  

International Nuclear Information System (INIS)

We consider a D-brane probe in the unstable string background associated with flux branes. The twist in the spacetime metric reponsible for supersymmetry breaking is shown to manifest itself in the mixing of open Wilson lines with the phases of some adjoint matter fields, resulting in a nonlocal and nonsupersymmetric form of Yang-Mills theory as the probe dynamics. This provides a setup where one can study the fate of a large class of unstable closed string theories that includes as a limit type 0 theories and various orbifolds of type II and type 0 theories. We discuss the limit of C/Z_n orbifold in some detail and speculate on the couplings with closed string tachyons.

2002-04-15

192

hh911.cpr  

Science.gov (United States)

"ID# ","Measurement ID Number " "DATE ","Date " "JDATE ","Julian Date " "TIME ", "Local Time " "GMT ","Greenwich Mean Time " "BAND ","Dielectric Probe Band ...

193

X-ray Emission as a Probe of the Wind-Driven Shock in WR 140  

Science.gov (United States)

single star evolution. To understand the evolution of massive stars and their role in shaping the galaxy, understanding of the distribution of ...

194

X-15 Research Results: Chapter 9  

Science.gov (United States)

... hypersonic aerodynamic force, or the space-equivalent region. Some of these experiments change the X-15 from a research airplane to a kind of space probe, ...

196

SQUID Eddy Current Technique Applying Conformable Eddy ...  

Science.gov (United States)

... Accession Number : ADD344580. Title : SQUID Eddy Current Technique Applying Conformable Eddy Current Probes,. Corporate Author : ...

197

SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP - LAMBDA - NASA  

Science.gov (United States)

of the determinant of the parameter covariance matrix for each ... parameter covariance matrix, as obtained from the Markov chains. The basic set ...

198

Performance Evaluation of Several Types of Pulsed Eddy Current Probes for Detecting Wall Thickness Reduction  

Science.gov (United States)

In this paper, four different types of pulsed eddy current (PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction is achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the ...

2010-02-01

199

Molecular spectroscopy and planetary atmospheres  

Energy Technology Data Exchange (ETDEWEB)

With the improvements accomplished during the past 15 years in detection techniques and instrumentation and with the opening of space exploration, molecular spectroscopy has become a very efficient way to probe planetary atmospheres.

1984-01-01

200

Final Report of OT-45, PVM-8, and RVTO Weather ...  

Science.gov (United States)

... A second hydrometeor sampler (MRI Model 1220 ... The cloud particle probe normally installed in ... to the northeast showed no significant movement. ...

1975-07-01

201

Development of a Suite of Luciferase Gene Probes for the ...  

Science.gov (United States)

... between 2 strains is acquired by adding the lengths of the connecting branches, using the scale which depicts 1 amino acid substitution per 10 ...

2011-05-15

202

Development of a FeCoNb Alloy to be used in Eddy Current ...  

Science.gov (United States)

... Accession Number : ADD336001. Title : Development of a FeCoNb Alloy to be used in Eddy Current Probes for Testing Ferromagnetic Tubes,. ...

203

Deep Space Probe Science Experiment  

Science.gov (United States)

Briefly, 48 MOS microparticle sensors (essentially the same as those flown on .... at the Naval Research Lab to interpret the polarization of the incoming radio .... Adapter Satellite, to be published in Journal of Spacecraft and Rockets, 1994. ...

204

Automated Eddy Current Inspection of Space Shuttle APV ...  

Science.gov (United States)

... perform the inspection in the extremely limited space between adjacent blades and at the blade root, miniature eddy current probes were developed ...

205

Ultrasmall spot size scanning laser ophthalmoscopy  

UK PubMed Central (United Kingdom)

An ultrasmall spot size scanning laser ophthalmoscope has been developed that employs an annular aberration-corrected incident beam to increase the effective numerical aperture of the eye thereby reducing...Full Text Available

206

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

207

Role of Quantitative Bone Scanning in the Assessment of Bone Turnover in Patients With Charcot Foot  

UK PubMed Central (United Kingdom)

OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available

2010-02-01

208

New retinal imaging for the visualization and analysis of vitreoretinal interface (VRI) by short-wavelength scanning laser ophthalmoscope (swSLO)  

UK PubMed Central (United Kingdom)

Background:The purpose of the study was to evaluate vitreoretinal interface (VRI) alteration with a short-wavelength scanning laser ophthalmoscope (swSLO), the Nidek F-10, and compare...Full Text Available

2011-01-01

209

Quantum simulation of molecular interaction and dynamics at surfaces  

British Library Electronic Table of Contents (United Kingdom)

The interaction between molecules and solid surfaces plays important roles in various applications, including catalysis, sensors, nanoelectronics, and solar cells. Surprisingly, a full understanding of molecule-surface interaction at the quantum mechanical level has not been achieved even for very simple molecules, such as water. In this mini-review, we report recent progresses and current status of studies on interaction between representative molecules and surfaces. Taking water/metal, DNA bases/carbon nanotube, and organic dye molecule/oxide as examples, we focus on the understanding on the microstructure, electronic property, and electron-ion dynamics involved in these systems obtained from first-principles quantum mechanical calculations. We find that a quantum mechanical description ...

2011-01-01

210

Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters  

British Library Electronic Table of Contents (United Kingdom)

A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...

2011-01-01

211

High capacity Si/DC/MWCNTs nanocomposite anode materials for lithium ion batteries  

International Nuclear Information System (INIS)

Nanocomposites comprising nanocrystal silicon (Si), disordered carbon (DC), and multi-walled carbon nanotubes (MWCNTs) - denoted as Si/DC/MWCNTs - have been prepared by pyrolyzing the phenol-formaldehyde resin (PFR) mixed with Si and MWCNTs. This nanocomposite anode material showed a discharge capacity of 1216 mAh/g in the first cycle, and a charge capacity of 711 mAh/g after 20 charge-discharge, much higher than that of Si/DC composite. It can be observed that Si particles wrapped in MWCNTs were homogeneously embedded into the matrix of the DC. The improved electrochemical performance is hypothesized to be mainly attributed to the morphology stability of the composite due to the excellent resiliency and distinct electric conductivity of the MWCNTs.

2010-03-18

212

Flexible, all-organic ammonia sensor based on dodecylbenzene sulfonic acid-doped polyaniline films  

International Nuclear Information System (INIS)

A stable chlorobenzene dispersion of conducting polyaniline (PANI) has been obtained by doping emeraldine base with dodecylbenzene sulfonic acid (DBSA) and studied by spectrophotometric measurements in the UV-vis-IR range. The electrical properties of PANI: DBSA films obtained from the above dispersion have been investigated under different temperature and relative humidity conditions. All-organic chemoresistive devices have been developed by spin-coating the PANI: DBSA dispersion on flexible substrates, and then by depositing electrodes on the top, from a carbon nanotube conducting ink. Sensing tests performed under exposition to calibrated amounts of ammonia reveal that these simple and inexpensive sensors are able to detect ammonia at room temperature in a reliable way, with a sensitivity linearly related to concentration in the range between 5 ppm and 70 ppm.

2010-09-30

216

Patterns of gallium-67 scintigraphy in patients with acquired immunodeficiency syndrome and the AIDS related complex  

Energy Technology Data Exchange (ETDEWEB)

Thirty-two patients with AIDS related complex (ARC) or acquired immunodeficiency syndrome (AIDS) underwent /sup 67/Ga scans as part of their evaluation. Three patterns of /sup 67/Ga biodistribution were found: lymph node uptake alone; diffuse pulmonary uptake; normal scan. Gallium-67 scans were useful in identifying clinically occult Pneumocystis carinii pneumonia in seven of 15 patients with ARC who were asymptomatic and had normal chest radiographs. Gallium scans are a useful ancillary procedure in the evaluation of patients with ARC or AIDS.

1987-07-01

217

Environmental scanning electron microscopy  

Energy Technology Data Exchange (ETDEWEB)

The ElectroScan environmental scanning electron microscope (ESEM) is one of the most exciting new developments in the field of Electron Microscopy. The ESEM differs from conventional Scanning Electron Microscopes (SEM) by being able to examine materials including liquids and oils in their natural state with no prior sample preparation. Accessory equipment, cooling, heating and manipulating devices allow the manipulation of samples thus making it possible for the first time to image dynamic processes such as wetting, drying, absorption, corrosion, melting, crystallisation, curing and fracturing at high magnification. Papers concerning the historical development of the ESEM are given in a bibliography at the end of this paper. 24 refs., 18 figs.

1994-12-31

218

Burned Timber Canyon  

Science.gov (United States)

The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....

220

Inguino-scrotal hernia detection in the early phase of a bone scan  

International Nuclear Information System (INIS)

A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd

1999-11-01

221

Gamma scanning of FBTR fuel pins  

International Nuclear Information System (INIS)

This paper presents the results obtained in the gamma scanning of two fuel pins from the bent subassembly of the fast breeder test reactor (FBTR) using a segmented gamma scanning system employing segment correlation developed for the assay of glove box solid waste. In addition to the actinide profiles, the paper also discusses the fission products and clad activation product profiles and tries to correlate the experimental values of the latter with computed values. (author). 4 refs., 1 fig., 1 tab.

222

Computer analysis and control for nondestructive gamma scanning of LMFBR fuel pins  

International Nuclear Information System (INIS)

A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.

223

Brain and bone scans in primary Ewing's sarcoma of the petrous bone: case report  

International Nuclear Information System (INIS)

The authors present a case in which primary Ewing's sarcoma of the right petrous pyramid in a 9-year-old girl showed no uptake on a /sup 99m/Tc-pertechnetate nuclide angiogram. Intense uptake was present on a /sup 99m/Tc-polyphosphate bone scan, but a static brain scan was only minimally abnormal. The diagnosis and treatment of Ewing's sarcoma are reviewed.

224

Use of Eu"3"+ as an oxygen environment probe in alkali-alkaline earth-lanthanide phosphates with the #beta#-K_2SO_4 structure  

International Nuclear Information System (INIS)

The use of europium as a local structural probe allows the various phases appearing in the NaCaPO_4-Na_3Eu(PO_4)_2 and NaSrPO_4-Na_3Eu(PO_4)_2 systems to be detected. The broadening of the europium emission lines in going from the calcium to the strontium phases illustrates the ease of displacement of the PO_4 groups. (Auth.).

1983-09-01

225

The fatty acid analogue 11-(dansylamino)undecanoic acid is a fluorescent probe for the bilirubin-binding sites of albumin and not for the high-affinity fatty acid-binding sites.  

UK PubMed Central (United Kingdom)

1. The fluorescent fatty acid probe 11-(dansylamino)undecanoic acid (DAUDA) binds with high affinity to bovine and human serum albumin (BSA and HSA) at three sites. 2. The Kd of the primary binding...Full Text Available

1990-08-15

226

Surface probe measurements in ISX-B and EBT-S  

Energy Technology Data Exchange (ETDEWEB)

Surface deposition probe techniques have been shown to be an effective means of determining the characteristics of the plasma edge region of magnetic confinement devices. Experimental results on ISX-B and EBT-S have led to a consistent picture of the edge plasma and the dominant impurity introduction mechanisms. This picture is supported by numerous other measurements and emphasizes the importance of concentrating several techniques on the complex problems of plasma fusion.

1982-12-01

227

Non-destructive measurement of corrosion effects on high temperature coatings  

Energy Technology Data Exchange (ETDEWEB)

Non-destructive methods for measuring the remaining anticorrosive or antioxidative ability of coatings are investigated. For anticorrosive chromium coatings the increasing ferromagnetism caused by loss of chromium is measured by a permeability probe. Measured values on blades after operation are correlated with the progress of corrosion as determined by metallographic methods. For antioxidative aluminum coatings the diminishing layer thickness is taken as indication for the exhaustion of their protection ability. The layer thickness is measured eddy current probes, especially developed for this application.

1990-01-01

228

Hybridization with synthetic oligonucleotides  

Science.gov (United States)

Procedures are described for the use of synthetic oligonucleotides for Southern blot experiments and gene bank screening, and the effect of various mismatches on the efficiency of hybridization is demonstrated. The following topics are discussed: sensitivity vs. specificity, hybridization of a 12-mer to the lambda endolysin gene; hybridization of oligonucleotide probes to the E. coli lac operator; hybridization of synthetic probes to the CYC1 gene of yeast; and cloning eucaryotic genes. (HLW)

1978-01-01

229

Experimental study on the uses of SQUID magnetometers as sensitive, low-frequency eddy current probes for non-destructive materials evaluation. Final report  

International Nuclear Information System (INIS)

The results show that the SQUID device eddy current testing system is a suitable tool for NDE. Due to the high low-frequency sensitivity of the SQUID sensor, the SQUID device eddy current testing system permits lower examination frequencies than the conventional eddy current probe system. The SQUID system enhances fault detection in even deeper materials layers. (orig./MM).

1996-01-01

230

Eddy current testing of CFRP; New probes and techniques. Wirbelstrompruefung von Kohlefaser-Kompositen; Neue Sonden und Messverfahren  

Energy Technology Data Exchange (ETDEWEB)

Nondestructive inspection of carbon fibre-reinforced plastics (CRFP) using eddy current methods is based not only on the conductivity of the fibres. High frequencies (up to 10 MHz) give access to capacitive effects reflecting properties of the matrix. The paper presents a method using rotating eddy current probes to measure the anisotropic electrical properties. Potential applications of this method are the structural identification of laminates and the estimating of its degradation. (orig.)

1994-01-01

231

Diagnosis of early human myocardial ischemic damage with electron probe microanalysis  

Energy Technology Data Exchange (ETDEWEB)

We determined the Na/K x-ray intensity ratio in frozen sections of myocardial tissues obtained at autopsy from patients who died from various causes, using electron probe analysis. We have been able to distinguish between the ischemically injured and normal cells. The method is simple, fast, and dependable even when the duration of ischemia is only 30 minutes.

1983-03-01

232

Characterization of eddy current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.

1985-02-01

233

Characterization of Eddy Current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.

1985-02-01

234

A study of the eddy-current method of testing the level of molten steel in the thin-slab crystallization process  

British Library Electronic Table of Contents (United Kingdom)

An eddy current probe of the level of molten metal is considered for a sectional machine of continuous casting of steel. The advantages of electromagnetic probes of the level over radiometric ones lie in their insensitivity to the layer of dross and high speed. The results and directions of further studies are given.

2009-01-01

235

The usefulness of CBF brain SPECT in forensic medicine: the civil law codes cases. A description of four cases  

International Nuclear Information System (INIS)

The aim of this report was to assess the usefulness of cerebral blood flow (CBF) scanning utilising the SPECT technique in forensic medicine cases in the area of civil law cases. CBF SPECT scanning was performed in four patients utilising "9"9"mTc-ECD and a triple-head gammacamera. In the analysis both the asymmetry index and cerebellar normalisation were applied. Reference values were obtained by studying 30 healthy volunteers. In those cases CBF SPECT scanning played an important role in forensic argument. It influenced the sentence and the amount of financial compensation. CBF SPECT scanning may provide valuable information in forensic medicine argument in civil law cases, but only when taken together with psychometric tests and other neuroimaging methods (CT, MRI). The value of CBF SPECT scanning alone may be limited in judicial proceedings. (author)

236

Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...

2009-01-01

237

Use of DNA probes to study tetracycline resistance determinants in gram-negative bacteria from swine  

Energy Technology Data Exchange (ETDEWEB)

Specific {sup 32}P-labeled DNA probes were prepared and used to evaluate the distribution of tetracycline resistance determinants carried by gram-negative enteric bacteria isolated from pigs in 3 swine herds with different histories of antibiotic exposure. Plasmid DNA, ranging in size from 2.1 to 186 Kb, was observed in over 84% of 114 isolates studied. Two of 78 tetracycline resistant strains did not harbor plasmids. The DNA probes were isolated from plasmids pSL18, pRT29/Tn10, pBR322 and pSL106, respectively, and they represented class A, B, C and D tetracycline resistance determinants. Hybridization conditions using 0.5X SSPE at 65{degrees}C minimize cross-hybridization between the different class of tetracycline resistance genes. Cross-hybridization between class A and class C determinants could be distinguished by simultaneous comparison of the intensity of their hybridization signals. Plasmids from over 44% of the tetracycline resistant ...

1989-01-01

238

Geometrically anisotropic probes: an improved eddy current technique  

Energy Technology Data Exchange (ETDEWEB)

Geometrically anisotropic eddy current probes are a type of separate function probes especially fit to the detection of defects showing a preferential direction. This kind of flaw induces a coupling between the transmitter and the receiver by guiding eddy currents from the one to the other. On the other hand, this coupling will be almost non-existent in the presence of defects or spurious effects not displaying this geometrical particularity. Basic studies on an elementary two-coil set-up allow the acknowledgment of the intrinsic qualities of such probes: good signal-to-noise ratio, influence field practically constant on the whole defect length, ability to detect bridged defects, insensitivity to lift off. These results can be improved by achieving multicoils probes adapted to different kinds of problems. An application to continuous casting slabs testing yields very interesting results in the ...

1987-06-01

239

Use of polymer conductors for welding thermoplastic materials  

International Nuclear Information System (INIS)

Although some polymer conductors of electricity (ex. Polyanilines) are materials known for more than 100 years, only recently have the interesting chemical, electrical and optic properties of their insulating and conducting forms been recognized. Advances made in the chemistry of polymer conductors have also led to improvements in processing them. This work studies a practical application of these materials: the use of polymer conductors for the remote welding of insulating thermoplastic polymers, using energy from microwaves for the local heating of the union. Many thermoplastics (for ex. Polyethylene) do not absorb, or absorb very little, energy from microwaves. Different conductor materials (conductor polymers, carbon nanotubes), however, heavily absorb energy from microwaves with the resulting heating. In this way the welding zone can be heated without affecting the rest of the piece. Conductor polymers (polyanilines) were synthesized chemically and they were ...

2004-11-01

240

Tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films  

International Nuclear Information System (INIS)

A highly sensitive and stable tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)_3 "2"+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)_3 "2"+ immobilized in the ECL sensor by adsorption of Ru(bpy)_3 "2"+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both titania-Nafion composite films ...

2006-04-13

241

Tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films  

Energy Technology Data Exchange (ETDEWEB)

A highly sensitive and stable tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy){sub 3} {sup 2+}) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy){sub 3} {sup 2+} immobilized in the ECL sensor by adsorption of Ru(bpy){sub 3} {sup 2+} onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both ...

2006-04-13

242

Large-scale production of single-walled carbon nanotubes by induction thermal plasma  

International Nuclear Information System (INIS)

High quality single-walled carbon nanotubes (SWNT) have been synthesized at large scales by the method of direct evaporation of carbon black and metallic catalyst mixtures, using induction thermal plasma technology. The processing system consists mainly of an RF plasma torch, which generates a plasma jet of extremely high temperature (?15 000 K), with a high energy density and abundance of reactive species (ions and neutrals). With the present reactor system, it has been demonstrated that carbon soot product which contains approximately 40 wt% of SWNT can be continuously synthesized at the high production rate of ?100 g h-1. The processing parameters involved have been examined closely in order to evaluate their individual influences on SWNT synthesis. The results have shown that the quality and purity of the SWNT produced are critically affected by the grade of carbon black, the plasma gas composition and the metallic catalyst employed. Theoretical calculations, ...

2007-04-21

243

Determination of endocrine-disrupting compounds in water by carbon nanotubes solid-phase microextraction fiber coupled online with high performance liquid chromatography.  

Science.gov (United States)

The commercial solid phase microextraction (SPME) fibers are not stable enough in organic solvent and tend to swell and strip off from the silica fiber in the high performance liquid chromatography (HPLC) mobile phase, and therefore the application of SPME coupled online with HPLC is limited. In this study, an SPME fiber coated with single walled carbon nanotubes (SWCNTs), prepared by means of electrophoretic deposition, was coupled on line to HPLC for the determination of four endocrine-disrupting compounds, i.e. bisphenol A (BPA), estrone (E(1)), 17?-ethynylestradiol (EE(2)) and octylphenol (OP), in aqueous samples. The results showed that the SWCNTs coating on the prepared fiber did not swell and strip off from the platinum fiber throughout the experiment, thus indicating a high resistance to the HPLC mobile phase, the mixture of water and acetonitrile. The SWCNTs fiber had similar (for OP) or higher (for BPA, EE(2) and E(1)) extraction efficiencies than the ...

2011-07-27

244

Aggressive Ewing's sarcoma appearing as a cold lesion on bone scan  

International Nuclear Information System (INIS)

Ewing's sarcoma classically presents as a hot spot on bone scan as a result of increased vascularity of the tumor and new bone formation. Purpose We report and analyze an uncommon pattern of a 'cold' lesion in Ewing's sarcoma on bone scan and its pathophysiologic significance. Case report A 15-year-old boy complaining of thigh pain. CT scan evoked Ewing's sarcoma or osteitis. MRI evoked chronic osteitis. Scintigraphy showed a fairly intense and heterogeneous uptake on the femoral lesion and no abnormal uptake elsewhere. Biopsy showed none pathologic pattern. Three months later, a second biopsy concluded to Ewing's sarcoma. Bone scan showed a larger lesion with peripheral intense uptake centered by enlarged 'cold' area in the left femoral diaphysis and no evident bone metastasis. The patient underwent chemotherapy and surgery. Three months later, bone scan showed extensive skeletal ...

2009-10-01

245

Characterization of axial probes used in eddy current testing; Caracterisation des sondes axiales utilisees en courants de foucault  

Energy Technology Data Exchange (ETDEWEB)

Customized reference tubes reduced sensitivity discrepancies able to be observed from one probe to the other, due to the gain setting adjustment required for a pre-definite level in amplitude response of the artificial notch. The use of a reference circuit in place of a reference part, makes characterization of the probe matched to its generator more accurate: - the material dependence is cancelled during the compensation process, - the reference signal can be adjusted more accurately in amplitude and phase response, - the manufacturing cost is reduced compared to the one necessary for machining the reference part, - the amplitude and phase response of the reference circuit can be simply modelled by using the transformer relations, such as one can appreciate the variations of the probe definition parameters and its connexion to the generator, and makes them optimal for use. The method proposed by ALSTOM for the ...

2001-07-01

246

Sequential injection system for phospholipase A2 activity evaluation: Studies on liposomes using an environment-sensitive fluorescent probe  

British Library Electronic Table of Contents (United Kingdom)

This work reports the development of an automatic methodology based on the use of 1-anilinonaphthalene-8-sulfonate (ANS) as an interfacial fluorescent probe for detecting the hydrophobic environment shift around the probe, caused by the hydrolytic action of PLA2 on the liposomes. The implementation of this reaction in a sequential injection analysis (SIA) system along with the use of the mixing chambers permitted the evaluation of PLA2 activity and assessment of the inhibitory effect of the non-steroidal anti-inflammatory drugs (NSAIDs) on PLA2 activity. Several studies were performed with the aim of establishing the appropriate flow system configuration: the liposome substrate; PLA2 and ANS optimum concentrations and incubation times before and after the enzyme addition. Based on these st...

2009-01-01

247

Probing anomalous quartic couplings in e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We analyze the potential of the e{sup +}e{sup -} linear colliders, operating in the e{gamma} and {gamma}{gamma} modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2){sub L}(circle times)U(1){sub Y} chiral operators of order p{sup 4} that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e{gamma} and {gamma}{gamma} modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10{sup -2} at 90% C.L. Moreover, the information gathered in the e{gamma} mode can be used to reduce the ambiguities of the e{sup +}e{sup -} mode.

2001-10-01

248

Probing anomalous quartic couplings in e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We analyze the potential of the e"+e"- linear colliders, operating in the e#gamma# and #gamma##gamma# modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2)_L(circle times)U(1)_Y chiral operators of order p"4 that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e#gamma# and #gamma##gamma# modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10"-"2 at 90% C.L. Moreover, the information gathered in the e#gamma# mode can be used to reduce the ambiguities of the e"+e"- mode.

2001-10-01

249

Microtiter plate assay for phosphate using a europium-tetracycline complex as a sensitive luminescent probe  

Energy Technology Data Exchange (ETDEWEB)

A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 {mu}mol/L. The probe is excited at 400 nm and displays a large Stokes' shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 x 10{sup -6} mol/L to 7.5 x 10{sup -4} mol/L of phosphate, and the limit of detection is 3 {mu}mol/L.

2006-01-12

250

Extra-dimensional gravity and dijet production at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

In this Brief Report, we consider dijet production at {gamma}{gamma} colliders as a probe of recently proposed, large extra-dimensional gravity models. The exchange of virtual, spin-2 graviton towers (Kaluza-Klein excitations) significantly modifies the cross section, as compared to the standard model predictions. We find that, in order to maximize the value of the effective scale that can be probed at a given center-of-mass energy, a very severe p{sub T} cut should be applied; in general, a p{sub T} equal to approximately 46% of the e{sup +}e{sup -} beam energy gives the highest reach. We find that we can probe the effective mass scale from about 2.7 TeV to 11.1 TeV, depending on the center-of-mass energy and assumptions about the model. (c) 2000 The American Physical Society.

2000-06-01

251

Extra-dimensional gravity and dijet production at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

In this Brief Report, we consider dijet production at #gamma##gamma# colliders as a probe of recently proposed, large extra-dimensional gravity models. The exchange of virtual, spin-2 graviton towers (Kaluza-Klein excitations) significantly modifies the cross section, as compared to the standard model predictions. We find that, in order to maximize the value of the effective scale that can be probed at a given center-of-mass energy, a very severe p_T cut should be applied; in general, a p_T equal to approximately 46% of the e"+e"- beam energy gives the highest reach. We find that we can probe the effective mass scale from about 2.7 TeV to 11.1 TeV, depending on the center-of-mass energy and assumptions about the model. (c) 2000 The American Physical Society

2000-06-01

252

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

253

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

254

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

255

Radionuclide liver and bone scanning in the evaluation of patients with endometrial carcinoma  

International Nuclear Information System (INIS)

Staging bone scans or skeletal surveys were obtained of 97 patients with endometrial carcinoma. Of the 77 patients with Stage I or II disease, no metastases were identified at staging. Three patients in the entire series demonstrated bony metastases; all of these metastases were detectable by radionuclide bone scan and radiographic bone survey. Eighty-nine patients were examined with radionuclide liver/spleen scanning at the time of staging. Four of the 89 initial scans were interpreted as demonstrating hepatocellular disease, and all four patients had abnormal liver function studies. Only one patient demonstrated a possible hepatic metastasis at initial diagnosis. This patient also had abnormal liver function studies. Based on these results, bone surveys and radionuclide bone scans are not indicated as screening procedures in endometrial carcinoma. It is suggested that screening ...

256

Detection of abnormalities in febrile AIDS patients with In-111-labeled leukocyte and Ga-67 scintigraphy  

International Nuclear Information System (INIS)

Thirty-six patients with acquired immunodeficiency syndrome (AIDS), who were febrile but without localizing signs, underwent indium-111 leukocyte scintigraphy 24 hours after injection of labeled white blood cells (WBCs) and were restudied 48 hours after injection of gallium-67 citrate. Fifty-six abnormalities were identified as possible sources of the fever; 27 were confirmed with biopsy. Of these 27, 15 were identified only on In-111 WBC scans (including colitis, sinusitis, and focal bacterial pneumonia); six, only on Ga-67 scans (predominantly Pneumocystis carinii pneumonia and lymphadenopathy); and six, on both studies (predominantly pulmonary lesions). In-111 WBC scanning revealed 21 of 27 abnormalities (78%) and gallium scanning, 12 of 27 (44%). If only one scintigraphic study has been performed, particularly with Ga-67, a significant number of lesions would not have been detected. The authors ...

257

CT diagnosis of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All lesions contained areas of delayed contrast ...

258

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

259

Role of nuclear medicine bone scans in evaluating pain in athletic injuries  

Energy Technology Data Exchange (ETDEWEB)

The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

1987-10-01

260

Bone scanning in Ewing's sarcoma  

International Nuclear Information System (INIS)

This is a retrospective analysis of bone scans in 72 patients with Ewing's sarcoma. Sites of primary disease were found to be evenly distributed among the axial skeleton and the proximal and distal extremities. Primary disease sites in the axial skeleton were more frequently associated with metastases. Fifty-three of these patients had their first scans done at presentation; among them, 25 were found to have metastases. Unsuspected metastases were picked up in 28 of all the patients. Metastases at presentation were seen to be associated with a poorer prognosis.

261

Size determination of Acipenser ruthenus spermatozoa in different types of electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

In this study three types of scanning electron microscopes were used for the size determination of spermatozoa of sterlet Acipenser ruthenus - high vacuum scanning electron microscope (SEM, JEOL 6300), environmental scanning electron microscope (ESEM, Quanta 200 FEG), field emission scanning electron microscope (FESEM, JEOL 7401F) with cryoattachment Alto 2500 (Gatan) and transmission electron microscope (TEM, JEOL 1010). The use of particular microscopes was tied with different specimen preparation techniques. The aim of this study was to evaluate to what degree the type of used electron microscope can influence the size of different parts of spermatozoa. For high vacuum SEM the specimen was prepared using two slightly different procedures. After chemical fixation with 2.5% glutaraldehyde...

2010-01-01

262

Scanning Electron Microscopy of Sarcophagid (Diptera) Larvae Recovered from a Case of Human Cutaneous Myiasis  

Science.gov (United States)

... point dried and mounted on aluminum stubs using colloidal silver paste. Mounted specimens were observed and photographed using ... ...

263

New Image - ONLY - Scan to PDF - NASA Technical Reports Server  

Science.gov (United States)

Aluminum electrolytic capacitors are presently not allowed ..... specified for commercial aluminum electrolytic capacitors of similar rating. ...

264

New Image - ONLY - Scan to PDF - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Variations,of-the ,rudder pedel force with.indicated airspeed are shown in figure 16 for the six vertical-tail configurations. -tested. ...

265

New Image - ONLY - Scan to PDF - NASA Technical Report Server (NTRS)  

Science.gov (United States)

ratio 2 with NACA 0005-63 thickness distribution in streamwise planes, and twisted and cambered for a trapezoidal span load distribution has ...

266

High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry  

CERN Document Server

In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.

2004-01-01

267

Habitat Selection by Mountain Plovers in Shortgrass Steppe  

Science.gov (United States)

... the area covered by the point-count grid, stopping approximately every 100 m, stepping away from the vehicle, and scanning with binoculars for mountain plovers. Once ... ...

268

FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...  

Science.gov (United States)

was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...

270

Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning  

International Nuclear Information System (INIS)

The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).

271

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This work describes scanning in charged-particle microscopes, which is applied both in the artificial image generator and the DCIC ...

2010-01-01

272

Wavelength-Dependent Differential Interference Contrast Microscopy: Selectively Imaging Nanoparticle Probes in Live Cells  

Energy Technology Data Exchange (ETDEWEB)

Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength DIC microscopy thus presents a new approach ...

2009-11-15

273

Transversal Stiffness and Young's Modulus of Single Fibers from Rat Soleus Muscle Probed by Atomic Force Microscopy  

UK PubMed Central (United Kingdom)

AbstractThe structural integrity of striated muscle is determined by extra-sarcomere cytoskeleton that includes structures that connect the Z-disks and M-bands of a sarcomere to sarcomeres...Full Text Available

2010-02-03

274

The efflux of a fluorescent probe is catalyzed by an ATP-driven extrusion system in Lactococcus lactis.  

UK PubMed Central (United Kingdom)

Many bacteria, both gram positive and gram negative, extrude in an energy-dependent manner the fluorescent pH indicator 2',7'-bis-(2-carboxyethyl)-5[and -6]-carboxyfluorescein (BCECF) (D. Molenaar,...Full Text Available

1992-05-01

275

The direct comparison of health and ulcerated stomach tissue: A multiple probe microdialysis sampling approach  

UK PubMed Central (United Kingdom)

The ability to directly compare gastric ulcerated and healthy tissue would aid in the understanding of the physiological differences between these tissue types. Presently, these comparisons...Full Text Available

2008-09-10

276

Strategies for the uses of lanthanide NMR shift probes in the determination of protein structure in solutio. Application to the EF calcium binding site of carp parvalbumin.  

UK PubMed Central (United Kingdom)

The homologous sequences observed for many calcium binding proteins such as parvalbumin, troponin C, the myosin light chains, and calmodulin has lead to the hypothesis that these proteins have homologous...Full Text Available

1980-10-01

277

Rapid technique of DNA-DNA in situ hybridisation on formalin fixed tissue sections using microwave irradiation.  

UK PubMed Central (United Kingdom)

The relative sensitivities of different protocols for detecting cytomegalovirus nucleic acid sequences in histological specimens, using a biotinylated cDNA probe, were assessed. Several commonly used...Full Text Available

1987-08-01

279

Probing the structural hierarchy and energy landscape of an RNA T-loop hairpin  

UK PubMed Central (United Kingdom)

The T-loop motif is an important recurrent RNA structural building block consisting of a U-turn sub-motif and a UA trans Watson–Crick/Hoogsteen base pair. In the presence of...Full Text Available

2007-11-01

280

Probing the Mechanisms of an Air Amplifier using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy  

UK PubMed Central (United Kingdom)

We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available

2007-11-01

281

Probing active galactic nuclei with H2O megamasers.  

UK PubMed Central (United Kingdom)

We describe the characteristics of the rapidly rotating molecular disk in the nucleus of the mildly active galaxy NGC4258. The morphology and kinematics of the disk are delineated by the point-like...Full Text Available

1995-12-05

282

Probing a Membrane Matrix Regulating Hormone Action  

UK PubMed Central (United Kingdom)

Auxin-induced pea (Pisum sativum) stem section elongation is enhanced at levels of 3 to 40 micromolar by six new classes of alkane derivatives additional to those described earlier,...Full Text Available

1971-11-01

283

Probing Compulsive and Impulsive Behaviors, from Animal Models to Endophenotypes: A Narrative Review  

UK PubMed Central (United Kingdom)

Failures in cortical control of fronto-striatal neural circuits may underpin impulsive and compulsive acts. In this narrative review, we explore these behaviors from the perspective of neural processes...Full Text Available

2010-02-01

284

Pressure Probe Technique for Measuring Water Relations of Cells in Higher Plants 1  

UK PubMed Central (United Kingdom)

A new method is described for continuously measuring cell turgor pressure (P), hydraulic conductivity (Lp), and volumetric elastic modulus (ε) in higher plant cells, using a pressure...Full Text Available

1978-02-01

285

Osmotically Induced Removal of Water from Fungal Cells as Determined by a Spin Probe Technique 1  

UK PubMed Central (United Kingdom)

Effects of physical environment on plasma membrane semipermeability and osmotic induction of changes in aqueous cytoplasmic volume were studied in vegetative and spore cells of a plant pathogenic fungus,...Full Text Available

1978-11-01

286

Near Infrared Dyes as Lifetime Solvatochromic Probes for Micropolarity Measurements of Biological Systems  

UK PubMed Central (United Kingdom)

The polarity of biological mediums controls a host of physiological processes such as digestion, signaling, transportation, metabolism, and excretion. With the recent widespread use of near-infrared...Full Text Available

2007-10-15

287

Multiple-element eddy current probes for enhanced inspection  

Energy Technology Data Exchange (ETDEWEB)

Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe design is multiple element sensors. ...

1993-07-01

288

Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking  

Science.gov (United States)

This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil ...

1992-08-01

289

Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil ...

1992-08-01

290

Localization of gold in synovial membrane of rheumatoid arthritis treated with sodium aurothiomalate. Studies by electron microscope and electron probe x-ray microanalysis.  

UK PubMed Central (United Kingdom)

The localization of gold in the synovial membrane of rheumatoid arthritis patients treated with sodium aurothiomalate was examined and quantitative analysis of epon-embedded sections was carried out...Full Text Available

1977-06-01

291

Ion clustering in aqueous solutions probed with vibrational energy transfer  

UK PubMed Central (United Kingdom)

Despite prolonged scientific efforts to unravel the hydration structures of ions in water, many open questions remain, in particular concerning the existences and structures of ion clusters in 1∶1...Full Text Available

2011-03-22

292

Investigation of the hadronic final state in electron-proton interactions at HERA  

Energy Technology Data Exchange (ETDEWEB)

The main subject of this thesis is the study of the hardronic final state in deep-inelastic electron-proton scattering. Theexperiment described in this thesis is performed with such a high resolution that the substructure of the proton is probed by the electron beam with a resolution of less than 10{sup -15} cm. (orig./HSI).

1995-09-18

293

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).

1976-03-09

294

In-Space Propulsion Program Advanced Sensor Project - NASA  

Science.gov (United States)

Aug 25, 2004 ... Current Developments in Future Planetary Probe Sensors: .... Data: Outgoing and incoming EIA RS-422 interface for serial data transmission (for electrical purposes only, .... Milos, et. al, Journal of Spacecraft & Rockets 1999 ...

295

In-Situ Atr Ftir Probe Investigation of Selective Organic Synthetic Routes Using Nanoscale Crystal Reactors  

Environmental Research Database

ObjectivesThe overall aim of this work is to use an in-situ FTIR probe to investigate selected heterogeneous catalysts in industrially relevant organic reactions. This approach will be broadly applicable to the UK fine chemical manufacturing base.~%~~%~The project has the following specific objectives:~%~~%~- To demonstrate and develop the use of an in-situ FTIR probe in a batch reactor at elevated temperatures (eg greater than 100 deg C) to monitor reactant usage and product formation.~%~~%~- To validat [continued...]DescriptionThis proposal concerns the in-situ study of catalytic processes and reaction kinetics. The catalysts concerned are microporous materials, such as, zeolites, containing pores and cavities of molecular dimensions. These catalysts constitute crystal reactors on a nanometer scale that are selective on a size and shape basis for organic molecules used in this ...

2003-01-31

296

In service inspection for steam generator tubes  

International Nuclear Information System (INIS)

In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.

1987-11-24

297

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

298

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

299

Fluorine-19 NMR Chemical Shift Probes Molecular Binding to Lipid Membranes  

UK PubMed Central (United Kingdom)

The binding of amphiphilic molecules to lipid bilayers is followed by 19F NMR using chemical shift and line shape differences between the solution and membrane-tethered states of...Full Text Available

2008-05-22

300

Five-Year Wilkinson Microwave Anisotropy Probe (WMAP1 - LAMBDA - NASA  

Science.gov (United States)

If we decompose C1 using SVD the parameter covariance matrix can be inverted to ... However, we can analyze the parameter covariance matrix directly by ...

301

Fatigue crack detection in aircraft skin structures using eddy current array technique  

International Nuclear Information System (INIS)

Detection of fatigue damage cracks in aircraft skin structures is an ongoing NDT challenge. Cracks growing rate is difficult to predict, and for this reason, it is important to detect them as soon as possible to avoid a catastrophic break. Eddy current methods are known and well-accepted techniques which are relatively simple to carry out. However, with conventional inspection of airframe structures using standard driver-pickup eddy current probes, it is difficult to detect small fatigue cracks initiated in the second layer of the skin and in the shadow region at fastener holes. Such difficulty is related to fasteners length and their spacing which reduces test sensitivity. This report explains the development of improved eddy current probe/technique to detect and visualize fatigue cracks in fasteners. In this study, an eddy current array probe was evaluated and new coil design was suggested. Several tests were conducted on ...

2004-01-01

302

Evaluation of 13C isotopic tracers for metabolic flux analysis in mammalian cells  

UK PubMed Central (United Kingdom)

13C metabolic flux analysis (MFA) is the most comprehensive means of characterizing cellular metabolic states. Uniquely labeled isotopic tracers enable more focused analyses to probe...Full Text Available

2009-11-01

303

Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools  

Energy Technology Data Exchange (ETDEWEB)

Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were evaluated primarily for ...

2009-07-01

304

Dissociation dynamics of methylal  

Energy Technology Data Exchange (ETDEWEB)

The dissociation of methylal is investigated using mass spectrometry, combined with a pyrolytic radical source and femtosecond pump probe experiments. Based on preliminary results two reaction paths of methylal dissociation are proposed and discussed. (author) 4 fig., 3 refs.

1999-08-01

305

Development of compression-controlled low-level laser probe system: towards clinical application  

UK PubMed Central (United Kingdom)

Various physico-chemical tissue optical clearing (TOC) methods have been suggested to maximize photon density in tissue. In order to enhance photon density, a compression-controlled low-level...Full Text Available

2010-09-01

306

Detecting variants with Metabolic Design, a new software tool to design probes for explorative functional DNA microarray development  

UK PubMed Central (United Kingdom)

BackgroundMicroorganisms display vast diversity, and each one has its own set of genes, cell components and metabolic reactions. To assess their huge unexploited metabolic potential...Full Text Available

307

Design of 240,000 orthogonal 25mer DNA barcode probes  

UK PubMed Central (United Kingdom)

DNA barcodes linked to genetic features greatly facilitate screening these features in pooled formats using microarray hybridization, and new tools are needed to design large sets of barcodes to allow...Full Text Available

2009-02-17

308

Design and Construction of a Versatile Dual Volume Heteronuclear Double Resonance Microcoil NMR Probe  

UK PubMed Central (United Kingdom)

Improved NMR detection of mass limited samples can be obtained by taking advantage of the mass sensitivity of microcoil NMR, while throughput issues can be addressed using multiple, parallel...Full Text Available

2009-04-01

309

Comparative analysis of nitrifying bacteria associated with freshwater and marine aquaria.  

UK PubMed Central (United Kingdom)

Three nucleic acid probes, two for autotrophic ammonia-oxidizing bacteria of the beta subdivision of the class Proteobacteria and one for alpha subdivision nitrite-oxidizing bacteria, were developed...Full Text Available

1996-08-01

310

Biotin-labeled hairpin oligonucleotides: probes to detect double-strand breaks in DNA in apoptotic cells.  

UK PubMed Central (United Kingdom)

Hairpin oligonucleotides were synthesized with stems ending in a double-stranded structure, which can be ligated to double-strand breaks in DNA, and with loops that contain nucleotides modified by the...Full Text Available

1998-04-01

311

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were different from those ...

312

An investigation of the distribution of resistivity in single crystal germanium ribbon by the single probe method  

CERN Document Server

Experimental data are reported on the micro-irregularities of resistivity in longitudinal and transverse specimens of germanium 0.5 to 0.8 mm in thickness and 25 to 40 mm in width. These data are correlated with the conditions of growth of the crystals. (16 refs).

1972-01-01

313

AeroSpace Information for a Changing World - NASA Technical ...  

Science.gov (United States)

Probing Neutron Star Evolution with Gamma Rays Online Source: Click to View PDF File [PDF Size: 217 KB] Author: Wijers, Ralph A. M. J. ...

314

A novel fluorescent pH probe for expression in plants  

UK PubMed Central (United Kingdom)

BackgroundThe pH is an important parameter controlling many metabolic and signalling pathways in living cells. Recombinant fluorescent pH indicators (pHluorins) have come into vogue...Full Text Available

315

A Meta-Analysis of Animal Studies on Disruption of Spatial Navigation by Prenatal Cocaine Exposure  

UK PubMed Central (United Kingdom)

Water-maze testing has been used to assess prenatal cocaine (PCOC)- induced deficits in behavioral studies of spatial navigation and memory abilities. Effects of PCOC in acquisition or in probe...Full Text Available

2007-01-01

316

Wilson loops in warped resolved deformed conifolds  

CERN Document Server

We calculate quark-antiquark potentials using the relationship between the expectation value of the Wilson loop and the action of a probe string in the string dual. We review and categorize the possible forms of the dependence of the energy on the separation between the quarks. In particular, we examine the possibility of there being a minimum separation for probe strings which do not penetrate close to the origin of the bulk space, and derive a condition which determines whether this is the case. We then apply these considerations to the flavoured resolved deformed conifold background of Gaillard et al. We suggest that the unusual behaviour we observe in this solution is likely to be related to the IR singularity which is not present in the unflavoured case.

2011-01-01

317

Use of Eu/sup 3 +/ as an oxygen environment probe in alkali-alkaline earth-lanthanide phosphates with the. beta. -K/sub 2/SO/sub 4/ structure  

Energy Technology Data Exchange (ETDEWEB)

The use of europium as a local structural probe allows the various phases appearing in the NaCaPO/sub 4/-Na/sub 3/Eu(PO/sub 4/)/sub 2/ and NaSrPO/sub 4/-Na/sub 3/Eu(PO/sub 4/)/sub 2/ systems to be detected. The broadening of the europium emission lines in going from the calcium to the strontium phases illustrates the ease of displacement of the PO/sub 4/ groups.

1983-09-15

318

The enteral probe nutrition with Cosilat in complex therapy of patients with radiotherapeutic late effects of the colon  

International Nuclear Information System (INIS)

Results are presented applying an enteral nutrition by means of probes with Cosilat in complex therapy of patients with radiotherapeutic late effects of the colon. This nutrition was prescribed with the intention to gave the colon a functional recovery and to guarantee optimal conditions for repair of radiation injuries. Good results were seen in 27 of 28 patients (96.7%), the situation of one patient (3.3%) continued without any change. Cosilat has a high nutritive value, good organoleptic qualities and is well digested without any complications. (author).

319

Principal geological results of petroleum and gas prospecting on Southern Sakhalin  

Energy Technology Data Exchange (ETDEWEB)

Results are given for deep-level petroleum and gas drilling probes in various coastal zones of Southern Sakhalin covering the Poronai depression and the Aniv Bay trough. The exploratory probes indicate that the Middle Miocence deposits of the Boundary trough contain commercial-size deposits of petroleum, that commercial-size gas deposits are in the upper Myocene deposits of the Aliv Bay trough, and that the upper Cretaceous and Cenozoic deposits of the eastern section of Southern Sakhalin lack folded deformations. 7 references, 2 figures.

1981-01-01

320

Plasma-edge studies in ISX-B and EBT-S using surface probes and laser-induced fluorescence  

Energy Technology Data Exchange (ETDEWEB)

Surface probe and laser-induced fluorescence measurements in ISX-B and EBT-S have made significant contributions to the understanding of plasma edge characteristics and plasma-surface interactions in these devices. Where comparison is possible, these techniques have led to results which are consistent with plasma diagnostics. Charge-exchange neutral sputtering and self-ion sputtering have been identified as the dominent heavy impurity release mechanisms in ISX-B and EBT-S, respectively.

1982-08-01

321

Deterministic loading of individual atoms to a high-finesse optical cavity  

CERN Document Server

Individual laser cooled atoms are delivered on demand from a single atom magneto-optic trap to a high-finesse optical cavity using an atom conveyor. Strong coupling of the atom with the cavity field allows simultaneous cooling and detection of individual atoms for time scales exceeding 15 s. The single atom scatter rate is studied as a function of probe-cavity detuning and probe Rabi frequency, and the experimental results are in good agreement with theoretical predictions. We demonstrate the ability to manipulate the position of a single atom relative to the cavity mode with excellent control and reproducibility.

2007-01-01

322

Detection of EDM defects under Monju support plate using experimental data from remote field eddy current probes and a multi-frequency algorithm  

International Nuclear Information System (INIS)

This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)

2006-07-01

323

APSIS - an Artificial Planetary System in Space to probe extra-dimensional gravity and MOND  

CERN Document Server

A proposal is made to test Newton's inverse-square law using the perihelion shift of test masses (planets) in free fall within a spacecraft located at the Earth-Sun L2 point. Such an Artificial Planetary System In Space (APSIS) will operate in a drag-free environment with controlled experimental conditions and minimal interference from terrestrial sources of contamination. We demonstrate that such a space experiment can probe the presence of a "hidden" fifth dimension on the scale of a micron, if the perihelion shift of a "planet" can be measured to sub-arc-second accuracy. Some suggestions for spacecraft design are made.

2006-01-01

324

A truly commercial product  

International Nuclear Information System (INIS)

In one of the first uses of high Tc superconductors in an end-use product, Lake Shore Cryotronics and a Swiss lab have developed a liquid nitrogen level sensor using a high Tc thin film. The probe is manufactured using a seamless stainless steel tube with an yttrium-based zirconium oxide flame-sprayed on the tube. A plasma-sprayed superconductor compound is deposited on top of that. The probe is coated with a sealant that protects the superconducting film from the atmosphere. This manufacturing method has yielded an extremely durable product. Unaffected by ice formation and related mechanical problems, the superconducting level sensor can be kept in the dewar for long periods of time.

325

$B \\to X_{s} \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ decays at LHCb  

CERN Document Server

\\lhcb is one of the four major experiments at the Large Hadron Collider (\\lhc) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavour hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiments. In this article, the \\lhcb prospects for such measurements with exclusive decays of the type $B \\to \\Xs \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ are presented.

2011-01-01

326

$B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ decays at LHCb  

CERN Document Server

LHC$b$ is one the four major experiments at the Large Hadron Collider (LHC) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavor hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiment. In this article, the LHC$b$ prospects for such measurement with exclusive decays of the type $B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ are presented.

2011-01-01

327

Simulating fullerene ball bearings of ultra-low friction  

Energy Technology Data Exchange (ETDEWEB)

We report the direct molecular dynamics simulations for molecular ball bearings composed of fullerene molecules (C{sub 60} and C{sub 20}) and multi-walled carbon nanotubes. The comparison of friction levels indicates that fullerene ball bearings have extremely low friction (with minimal frictional forces of 5.283 x 10{sup -7} and 6.768 x 10{sup -7} nN/atom for C{sub 60} and C{sub 20} bearings) and energy dissipation (lowest dissipation per cycle of 0.013 and 0.016 meV/atom for C{sub 60} and C{sub 20} bearings). A single fullerene inside the ball bearings exhibits various motion statuses of mixed translation and rotation. The influences of the shaft's distortion on the long-ranged potential energy and normal force are discussed. The phonic dissipation mechanism leads to a non-monotonic function between the friction and the load rate for the molecular bearings.

2007-03-21

328

Report on the project on the researcher dispatch type international joint research survey. Feasibility study for digging up the seeds for international joint research; Kenkyusha hakengata kokusai kyodo kenkyu chosa jigyo hokokusho. Kokusai kyodokenkyu sizu hakkutsu no tameno FS chosa  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of digging up themes of the joint research which develop the R and D in the industrial technology field in Japan to a new stage, researchers were sent to the world representing research institutes to conduct the research survey of 'Nano-structured carbon and hydrogen absorption' and 'Development of the creation technology of nano-porous materials.' As to the former, an experiment on electrochemical hydrogen absorption of carbon materials including nanotubes was conducted by researchers dispatched, but the large absorption amount was not observed. As to the latter, visits were paid to Fraunhofer Institute and the related facilities in Germany, Princeton University, MIT, GIT and Naval Research Laboratories in the U.S., Orleans University in France, AO Research Institute (bone repair study) in Switzerland, Cambridge University and University of Bristol in the U.K., etc., and the research survey was made on the ...

2001-03-01

329

Relation study of different properties for tertiary pulsed electrodeposited Ni-based nanocomposite with Al2O3/Y2O3/CNT nanopowders  

British Library Electronic Table of Contents (United Kingdom)

Electrodeposition of tertiary alumina/yttria/carbon nanotube (Al2O3/Y2O3/CNT) nanocomposite by using pulsed current has been studied in this investigation. Coating process has been performed on nickel sulphate bath and nanostructure of obtained compound layer is examined with high precision figure analysis of SEM nanographs. The effects of process variables, i.e., Y2O3 concentration, treatment time, frequency and duty cycle, have been experimentally studied. Statistical methods are used to achieve the minimum of corrosion rate and average size of nanoparticles. Finally the contribution percentage of different effective factors is revealed and confirmation run shows the validity of obtained results. Also it has been revealed that by changing the size of nanoparticles, corrosion properties o...

2011-01-01

330

Nanostructured mesoporous materials for lithium-ion battery applications  

Science.gov (United States)

The Energy crisis happens to be one of the greatest challenges we are facing today. In this view, much effort has been made in developing new, cost effective, environmentally friendly energy conversion and storage devices. The performance of such devices is fundamentally related to material properties. Hence, innovative materials engineering is important in solving the energy crisis problem. One such innovation in materials engineering is porous materials for energy storage. Porous electrode materials for lithium-ion batteries (LIBs) offer a high degree of electrolyte-electrode wettability, thus enhancing the electrochemical activity within the material. Among the porous materials, mesoporous materials draw special attention, owing to shorter diffusion lengths for Li+ and electronic movement. Nanostructured mesoporous materials also offer better packing density compared to their nanostructured counterparts such as nanopowders, nanowires, nanotubes etc., thus ...

2011-05-01

331

Large reversible Li storage of graphene nanosheet families for use in rechargeable lithium ion batteries.  

Science.gov (United States)

The lithium storage properties of graphene nanosheet (GNS) materials as high capacity anode materials for rechargeable lithium secondary batteries (LIB) were investigated. Graphite is a practical anode material used for LIB, because of its capability for reversible lithium ion intercalation in the layered crystals, and the structural similarities of GNS to graphite may provide another type of intercalation anode compound. While the accommodation of lithium in these layered compounds is influenced by the layer spacing between the graphene nanosheets, control of the intergraphene sheet distance through interacting molecules such as carbon nanotubes (CNT) or fullerenes (C60) might be crucial for enhancement of the storage capacity. The specific capacity of GNS was found to be 540 mAh/g, which is much larger than that of graphite, and this was increased up to 730 mAh/g and 784 mAh/g, respectively, by the incorporation of macromolecules of CNT and C60 to the GNS. ...

2008-07-24

332

Functional expression of anti-hepatitis B virus (HBV) preS2 antigen scFv by cspA promoter system in Escherichia coli and application as a recognition molecule for single-walled carbon nanotube (SWNT) field effect transistor (FET)  

British Library Electronic Table of Contents (United Kingdom)

The preS2 antigens of hepatitis B virus (HBV), which causes a serious health problem in the world, have been implicated in hepatocyte cell binding and viral penetration. Therefore, the importance of antibody production against preS2 antigen for early diagnosis of HBV has been well established. In this study, the recombinant HBV preS2 single chain variable fragment (scFv) antibody was successfully expressed in E. coli with the novel cold shock vector (pCold) under the cspA promoter, and its expression level was compared with the pET vector under the T7 promoter. Additionally, a host with an oxidizing cytoplasm, E. coli trxB/gor double mutant, was used to improve the soluble expression. The anti-HBV preS2 scFv using pCold vector was successfully expressed in a soluble and functional form in ...

2010-01-01

333

Effect of radiation dose on the properties of natural rubber nanocomposite  

Energy Technology Data Exchange (ETDEWEB)

Effect of radiation dose and carbon nanotubes (CNT) on the mechanical properties of standard Malaysian rubber (SMR) was investigated in this study. SMR nanocomposites containing 1-7 phr CNT were prepared using the solvent casting method and the nanocomposites were radiated at doses of 50-200 kGy. The change in mechanical properties, especially, tensile strength (Ts), elongation at break (Eb), hardness and tensile modulus at 100% elongation (M{sub 100}) were studied as a function of radiation dose. The structure and morphology of reinforced natural rubber was investigated by FESEM, TEM and AFM in order to gain further evidence on the radiation-induced crosslinking. It was found that the Ts, M{sub 100} and the hardness of the SMR/CNT nanocomposites significantly increased with radiation dose; the elongation at break exhibited an increase up to 100 kGy, and a downward trend thereafter. Results on gel fraction further confirmed the crosslinking of SMR/CNT ...

2010-12-15

334

Visualization and Analysis of Eddy Current Data from D-Probe  

Energy Technology Data Exchange (ETDEWEB)

Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The D-probe is ...

2009-05-15

335

Visualization and Analysis of Eddy Current Data from D-Probe  

International Nuclear Information System (INIS)

Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The D-probe is ...

2009-05-01

336

Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G  

Energy Technology Data Exchange (ETDEWEB)

Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the ...

1997-12-31

337

Edge biasing in the WEGA stellarator  

Energy Technology Data Exchange (ETDEWEB)

The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gas discharges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise measurement of the radial electric field. The ...

2009-02-27

338

Voronoi distance based prospective space-time scans for point data sets: a dengue fever cluster analysis in a southeast Brazilian town  

UK PubMed Central (United Kingdom)

BackgroundThe Prospective Space-Time scan statistic (PST) is widely used for the evaluation of space-time clusters of point event data. Usually a window of cylindrical shape is employed,...Full Text Available

339

Scanning tip microwave near-field microscope  

Energy Technology Data Exchange (ETDEWEB)

A near-field microscope which operates in the rf/microwave frequency range is described. In this microscope, a scanning tunneling microscope (STM)-like tip rather than an aperture is used as a point-like evanescent field emitter. A spatial resolution of {approximately}5 {mu}m ({approximately}{lambda}/100000) is achieved in the current version. The design of the microscope as well as the principal factors which affect its performance are discussed. {copyright} {ital 1996 American Institute of Physics.}

1996-06-01

340

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

341

Paraquat-induced pulmonary lesions : HRCT findings in long-term follow-up : a case report  

International Nuclear Information System (INIS)

We illustrate serial HRCT findings over a 16-month period in a 35-year-old woman who had ingested paraquat. Initial areas of ground-glass opacity changed into areas of multiple air cysts on follow up scan obtained five months after ingestion. A further follow-up scan obtained 16 months after ingestion showed improvement, with increased lung volume and normalized lung architecture.

1997-03-01

342

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

343

Isolated dextrogastria: report of two cases  

International Nuclear Information System (INIS)

Isolated situs inversus of the stomach with otherwise normal position of the thoracic and abdominal viscera is an extremely rare anomaly occurring in two distinct forms. Because of its close relationship to the liver, the right-sided stomach may produce interesting and confusing changes in the liver scan. Two cases illustrate the radiologic features of the two principal types of isolated congenital dextrogastria and the effect of one type on the liver scan.

344

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system  

International Nuclear Information System (INIS)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).

345

Incidental orbital calcifications on computed tomography scans; Calcificacoes orbitarias incidentais na tomografia computadorizada  

Energy Technology Data Exchange (ETDEWEB)

We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)

2001-02-01

346

IMEF gamma scanning system  

International Nuclear Information System (INIS)

The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

1989-09-10

347

Development of heavy-ion irradiation technique for single-event in semiconductor devices  

Energy Technology Data Exchange (ETDEWEB)

Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

1997-03-01

348

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

349

Bone scintigraphy in Ewing's sarcoma during and after treatment - prognostic information from the primary tumor site  

International Nuclear Information System (INIS)

A bone scan can be negative in Ewing's sarcoma. The bone scan during and after treatment can give prognostic information on the primary tumor site: A persisting hot spot strongly suggests the presence of local malignancy, while a hot spot becomming negative points to local cure of Ewing's sarcoma. (orig.).

350

Localization of islet cell tumors by dynamic CT: comparison with plain CT, arteriography, sonography, and venous sampling  

Energy Technology Data Exchange (ETDEWEB)

Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the appropriate level ...

1984-09-01

351

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel ...

352

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel ...

2007-03-15

353

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. Additionally, larger ...

2008-07-01

354

Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences  

Energy Technology Data Exchange (ETDEWEB)

To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdominal and intermediate window) and three-dimensionally (manually and semi-automatically). Linear mixed models were used to assess the variability and systematic differences between CT colonography and optical colonoscopy techniques. The variability of forceps and linear probe measurements was comparable and both showed less variability than measurement by visual assessment. Measurements by linear probe were 0.7 mm smaller than measurements by visual assessment or by forceps. The variability of all CT colonography techniques was lower than for measurements by forceps or visual assessment and sometimes lower (only 2D intermediate window ...

2010-06-15

355

Corrosion probes for fireside monitoring in coal-fired boilers  

Energy Technology Data Exchange (ETDEWEB)

Corrosion probes are being developed and combined with an existing measurement technology to provide a tool for assessing the extent of corrosion of metallic materials on the fireside in coal-fired boilers. The successful development of this technology will provide power plant operators the ability to (1) accurately monitor metal loss in critical regions of the boiler, such as waterwalls, superheaters, and reheaters; and (2) use corrosion rates as process variables. In the former, corrosion data could be used to schedule maintenance periods and in the later, processes can be altered to decrease corrosion rates. The research approach involves laboratory research in simulated environments that will lead to field tests of corrosion probes in coal-fired boilers. Laboratory research has already shown that electrochemically-measured corrosion rates for ash-covered metals are similar to actual mass loss corrosion rates. Electrochemical tests conducted ...

2005-01-01

356

Computer modelling of eddy current probes for ISI of pressure tube/calandria tube assemblies in PHWRs  

International Nuclear Information System (INIS)

Non-destructive Evaluation (NDE) plays a major role in ensuring the safe and reliable operation of PHWRs which are the mainstay of India's nuclear power programme. An important in-service inspection (ISI) requirement in these reactors is carried out through Eddy Current Testing (ECT) of the pressure tube (PT)/calandria tube (CT) assemblies. The material of construction of these assemblies is zircaloy-2. The two main objectives of this ISI are the detection of garter spring between CT and PT and the profiling of gap between CT and PT. The paper discusses the work carried out at the authors' laboratory on the development of ECT probes for ISI of PT/CT assemblies. Emphasis has been given on the work done on the design and optimisation of the probes using computer modeling. A 2-D finite element code has been developed for this purpose. The code is developed around a diffusion equation which can be derived from Maxwell's equations governing the ...

1991-12-01

357

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among individual cells by electron ...

1986-01-01

358

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis  

International Nuclear Information System (INIS)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among individual cells by electron ...

1986-01-01

359

The surface topography of the choroid plexus. Environmental, low and high vacuum scanning electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

Environmental scanning electron microscopy (ESEM) allows the examination of hydrated and dried specimens without a conductive metal coating which could be advantageous in the imaging of biological and medical objects. The aim of this study was to assess the performance and benefits of wet-mode and low vacuum ESEM in comparison to high vacuum scanning electron microscopy (SEM) using the choroid plexus of chicken embryos as a model, an organ of the brain involved in the formation of cerebrospinal fluid in vertebrates. Specimens were fixed with or without heavy metals and examined directly or after critical point drying with or without metal coating. For wet mode ESEM freshly excised specimens without any pre-treatment were also examined. Conventional high vacuum SEM revealed the characterist...

2011-01-01

360

Numerical modeling of scanning laser-induced melting, vaporization and resolidification in metals subjected to step heat flux input  

Energy Technology Data Exchange (ETDEWEB)

We present a 1-D heat transfer, melting, vaporization and resolidification model describing the interaction of a scanning continuous-wave laser with a metal surface wherein the beam power is constant. A physical model based on the Stefan problem is developed with appropriate boundary conditions. The effects of processing parameters on process variables are investigated numerically by varying beam diameters, scan speeds and substrate temperatures for Nickel. Relations are derived for the times to initiate melting, to initiate vaporization, to reach maximum melting depth, for melting-resolidification, and for maximum melting and vaporization depths. Surface temperatures are compared with approximate closed form solutions. (Author)

2004-09-01

361

Interpretation of gamma-scanning data from the ORR demonstration elements  

Energy Technology Data Exchange (ETDEWEB)

The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.

1989-01-01

362

High speed inverted optical-resolution photoacoustic microscopy  

Science.gov (United States)

Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.

2011-02-01

363

Versatile high intensity plasma sputter heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A multicusp magnetic field plasma surface ion source, normally used for H/sup -/ ion beam formation, has been utilized for the generation of high intensity, pulsed, heavy negative ion beams suitable for a variety of uses including tandem electrostatic accelerator/synchrotron injection applications. Sputter probe voltage limited total ion currents of 5.5, 8.2, 5.1 and 4.5 mA (peak intensity) have been produced from Au, Cu, Ni and CuO sputter probes, respectively. The mass distributions of these ion beams are found to be dominated by Au/sup -/, Cu/sup -/, Ni/sup -/ and O/sup -/ atomic species, respectively. The source offers the interesting prospect of providing cw negative ion beams at mA intensity levels of the commonly used semiconducting material dopants (e.g. B/sup -/, P/sup -/, As/sup -/ and Sb/sup -/) as well as O/sup -/ for isolation barrier formation. Illustrative examples of intensity versus time and the mass distribution of ion beams ...

1988-07-01

364

Monitoring power plant fireside corrosion using corrosion probes  

Energy Technology Data Exchange (ETDEWEB)

The ability to monitor the corrosion degradation of key components in fossil fuel power plants is of utmost importance for Futuregen and ultra-supercritical power plants. Fireside corrosion occurs in the high temperature sections of energy production facilities due to a number of factors: ash deposition, coal composition, thermal gradients, and low NOx conditions, among others. Problems occur when equipment designed for either oxidizing or reducing conditions is exposed to alternating oxidizing and reducing conditions. This can happen especially near the burners. The use of low NOx burners is becoming more commonplace and can produce reducing environments that accelerate corrosion. One method of addressing corrosion of these surfaces is the use of corrosion probes to monitor when process changes cause corrosive conditions. In such a case, corrosion rate could become a process control variable that directs the operation of a coal combustion or coal gasification ...

2005-01-01

365

Evolution of surface roughness in silicon X-ray mirrors exposed to a low-energy ion beam  

International Nuclear Information System (INIS)

The possibility of smoothening aspherical X-ray mirrors by irradiation of the surface with a low-energy ion beam is investigated. Nanofocusing being the primary application of these mirrors the ion beam conditions must be optimized to achieve a surface roughness of the order of 0.1-0.2 nm. To address this issue a first study was performed on silicon flat substrates etched using ion energies ranging from 400 to 1200 eV. A second study consisted of eroding the silicon surface while varying the ion grazing incidence angle between 10 deg. and 90 deg. for a fixed value of the ion energy. The surface topography of the samples was characterized at various scales using atomic force microscopy (probed area: 1-10 ?m2), interferential optical microscopy (probed area: 1 mm2) and X-ray scattering (probed area: 100 mm2). Finally, a study by AFM of the evolution of the surface finish level of a silicon mirror after ion erosion at various ...

2010-05-01

366

Electrochemical detection of DNA hybridization based on silver-enhanced gold nanoparticle label  

Energy Technology Data Exchange (ETDEWEB)

An electrochemical detection method for analyzing sequence-specific DNA using gold nanoparticle DNA probes and subsequent signal amplification step by silver enhancement is described. The assay relies on the electrostatic adsorption of target oligonucleotides onto the sensing surface of the glassy carbon electrode (GCE) and its hybridization to the gold nanoparticle-labeled oligonucleotides DNA probe. After silver deposition onto gold nanoparticles, binding events between probe and target were monitored by the differential pulse voltammetry (DPV) signal of the large number of silver atoms anchored on the hybrids at the electrode surface. The signal intensity difference permits to distinguish between the match of two perfectly matched DNA strands and the near-perfect match where just one base pair was wrong. Coupled with this 'nanoparticle-promoted' reduction of silver signal amplification method, the ...

2002-10-03

367

Char particle fragmentation and its effect on unburned carbon during pulverized coal combustion. Quarterly report, October 1, 1993--December 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

The information reported is for the period October I to December 31, 1993. During this quarter, activities were undertaken in Task 2. Oxygen concentrations were measured in the post-flame region of the entrained flow reactor. The sampling probe was used for the hot gas tests to sample the gas stream. Samples were injected into a gas chromatograph to determine the oxygen concentration. Results agreed with thermoequilibrium calculations that yield equilibrium compositions based on the stoichiometry of the feed gases. The axial temperature distribution along the reactor centerline was measured using a silica-coated platinum-rhodium thermocouple. Two coating techniques were tested and it was found that flame-plating silica to the thermocouple wires produced a thinner coating than a ceramic adhesive technique and therefore a smaller radiation correction. Other activities this quarter included the fabrication of a solids sampling probe support ...

1994-02-01

368

Strong laser fields as a probe for fundamental physics  

CERN Document Server

Upcoming high-intensity laser systems will be able to probe the quantum-induced nonlinear regime of electrodynamics. So far unobserved QED phenomena such as the discovery of a nonlinear response of the quantum vacuum to macroscopic electromagnetic fields can become accessible. In addition, such laser systems provide for a flexible tool for investigating fundamental physics. Primary goals consist in verifying so far unobserved QED phenomena. Moreover, strong-field experiments can search for new light but weakly interacting degrees of freedom and are thus complementary to accelerator-driven experiments. I review recent developments in this field, focusing on photon experiments in strong electromagnetic fields. The interaction of particle-physics candidates with photons and external fields can be parameterized by low-energy effective actions and typically predict characteristic optical signatures. I perform first estimates of the accessible new-physics parameter space ...

2008-01-01

369

Properties of different eddy-current probes for steam generator tube testing  

Energy Technology Data Exchange (ETDEWEB)

With steam generator check testing, the numerous types of defect not only have to be detected reliably but also to be identified correctly and classified according to depth. A priori, no signals are provided by the physical eddy-current mechanism, i.e. the disturbance of an excited eddy-current field by a defect, which will allow unambiguous identification and classification of the defects. The task, therefore, consists in designing the eddy-current method in terms of measurement technology in such a way as to obtain useful detection, identification and classification by a translation of the signals as simple and as save as possible. Internal through-flow wils and internal rotating probes were examined for their suitability to fulfill this three-pronged task with steam generator inspection.

1981-01-01

370

Properties of different eddy-current probes for steam generator tube testing  

International Nuclear Information System (INIS)

With steam generator check testing, the numerous types of defect not only have to be detected reliably but also to be identified correctly and classified according to depth. A priori, no signals are provided by the physical eddy-current mechanism, i.e. the disturbance of an excited eddy-current field by a defect, which will allow unambiguous identification and classification of the defects. The task, therefore, consists in designing the eddy-current method in terms of measurement technology in such a way as to obtain useful detection, identification and classification by a translation of the signals as simple and as save as possible. Internal through-flow wils and internal rotating probes were examined for their suitability to fulfill this three-pronged task with steam generator inspection. (orig./RW).

1981-01-01

371

Plasma density measurement of electron cyclotron resonance ion source for neutron generator  

International Nuclear Information System (INIS)

It is a traditional method to diagnose electron-cyclotron-resonance (ECR) plasma source, using a single probe to measure the current-voltage curve of the plasma, based on which and theoretic formula the plasma density can be computed. The article adopts a Langmuir probe having a role of emission electrons to measure two different current-voltage curves with and without emission. It is ease to get the plasma potential via the inflexion of the two curves and compute directly various physical quantities by the assistant computer, such as electron temperature, electron/ion density, plasma potential etc. The deviation is about percent 1.8 between the measurement results by traditional and the new method, but the latter has higher efficiency. (authors)

2007-12-01

372

Metal ion complexation by ionizable crown ethers  

Energy Technology Data Exchange (ETDEWEB)

Research conducted since the last progress report includes the synthesis and characterization of twenty three novel proton-ionizable crown ether compounds. Metal ion complexation behavior of new and previously-synthesized proton-ionizable crown ether compounds has been probed by solvent extraction and transport across polymer-supported liquid membranes. The behavior of neutral polyether and proton-ionizable polyether ligands in polymeric membrane electrodes has been assessed. Studies of the use of proton-ionizable crown ethers for separation of lithium isotopes were initiated. Also, the thermodynamics of interactions between alkali metal cations and ionized crown ethers have been probed by titration calorimetry. 10 refs., 1 tab.

1989-09-01

373

Joule-Thomson cryogenic cooler with extremely high thermal stability  

Science.gov (United States)

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

1991-06-01

374

Gradiometry coexperiments to the gravity probe B and step missions  

Energy Technology Data Exchange (ETDEWEB)

The Gravity Probe-B (GP-B) spacecraft, designed to test predictions of general relativity, will fly in the mid 1990s. It will carry four electrostatically suspended gyroscopes in a cryogenic environment and will have a drag-free control system to minimize disturbances on the gyroscopes. The Stanford Test of Equivalence Principle (STEP) spacecraft, to fly later, will carry a set of test masses under very similar conditions. The possibility of using differential measurements of the GP-B gyroscopes suspension forces and the STEP tests mass displacement readout to form single-axis gravity gradiometers is explored. It is shown that the noise in the suspension systems is sufficiently small in the relevant frequency range, and that enough information is collected to compensate for the spacecrafts' attitude motion. Finally, using Breakwell's flat-earth approximation, these experiments are compared to other geodesy experiments and predict the contribution ...

1990-01-01

375

From dispersion relations to spectral dimension - and back again  

CERN Document Server

The so-called spectral dimension is a scale-dependent number associated with both geometries and field theories that has recently attracted much attention, driven largely though not exclusively by investigations of causal dynamical triangulations (CDT) and Horava gravity as possible candidates for quantum gravity. We advocate the use of the spectral dimension as a probe for the kinematics of these (and other) systems in the region where spacetime curvature is small, and the manifold is flat to a good approximation. In particular, we show how to assign a spectral dimension (as a function of so-called diffusion time) to any arbitrarily specified dispersion relation. We also analyze the fundamental properties of spectral dimension using extensions of the usual Seeley-DeWitt and Feynman expansions, and by saddle point techniques. The spectral dimension turns out to be a useful, robust and powerful probe, not only of geometry, but also of ...

2011-01-01

376

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the conclusions.

1986-04-01

377

Erosive radially-slotted discharge in sheet current mode  

CERN Document Server

New non-stationary non-contracted form of the erosive radially-slotted discharge as a thin round sheet with the current of the azimuth direction have been discovered, its existence beings stipulated by a radial transport-wave fluxes. Characteristic features of this discharge is self-confinement of the discharge current magnitude, corresponding decrease of the current pulse duration and occurrence of an energy and substance ejection with rather unusual properties. Measurements of kinetics of the discharge current, the plasma radiation intensity and an electrical probe signal, as well as the transmission electron microscope investigations of characteristic aerodisperse aggregates arising the erosive phase, have been carried out. The probe signal duration was about 10 times greater than that of the current; its kinetics was complicated suggesting existence in the slot of two components with fundamentally different properties and states of the ...

2001-01-01

378

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

379

Development of in-vessel reflood instrumentation at ORNL  

International Nuclear Information System (INIS)

A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate and supply instrument systems to the reflood facilities ...

2004-09-06

380

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

381

Density measurements of coal samples by different probe gases and their interrelation  

Energy Technology Data Exchange (ETDEWEB)

Density is useful in deducing the spatial structure of coals. In this paper, nitrogen has been used instead of the commonly employed helium, for the gas displacement pycnometer based density determination of a number of coals of Indian origin. The results show that the nitrogen-based densities are always higher than the helium-based ones. Also, empirical relationships between the helium-based and nitrogen-based coal densities have been developed by two modeling methods, namely, multi-variable regression and artificial neural networks. Although the two models have fared well, the neural network model exhibits a relatively better prediction accuracy and generalization performance than the regression model. This study thus demonstrates that nitrogen, which is cheaper and easily available, can be used gainfully as the probe gas for estimating the true density of coals. 23 refs., 1 fig., 3 tabs.

2007-07-15

382

Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter related bloodstream infection in patients after haematopoietic stem cell transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract In 46 febrile neutropenic patients who had undergone haematopoietic stem cell transplantation, the fluorescence in situ hybridisation using peptide nucleic acid probes (PNA FISH), Gram stain/acridine orange leukocyte cytospin (Gram/AOLC), and differential time to positivity (DTP) methods were performed for detection of catheter related bloodstream infections (CRBSIs). As compared with the DTP method (which detected 11 patients with CRBSI), the PNA FISH and the Gram/AOLC methods detected ten of 11 CRBSI patients, resulting in a sensitivity, specificity, negative predictive value and positive predictive value of 91%, 100%, 97% and 100%, respectively, for the PNA FISH method as well as for the Gram/AOLC method.

2010-01-01

383

Atom-probe field-ion microscopy investigation of CMSX-4 Ni-base superalloy laser beam welds  

Energy Technology Data Exchange (ETDEWEB)

CMSX-4 superalloy laser beam welds were investigated by transmission electron microscopy and atom probe field-ion microscopy (APFIM). The weld microstructure consisted of fine (10- to 50-nm) irregularly shaped {gamma}` precipitates (0.65 to 0.75 volume fraction) within the {gamma} matrix. APFIM compositions of the {gamma} and {gamma}` phases were found to be different from those in the base metal. Concentration profiles across the {gamma} and {gamma}` phases showed extensive variations of Cr, Co and Al concentrations as a function of distance within the {gamma} phase. Calculated lattice misfits near the {gamma}/{gamma}` interface in the welds are positive values compared to the negative values for base metal. (orig.).

1996-09-01

384

Assessing the acid properties of desilicated ZSM-5 by FTIR using CO and 2,4,6-trimethylpyridine (collidine) as molecular probes  

British Library Electronic Table of Contents (United Kingdom)

A series of desilicated ZSM-5 catalysts previously shown to have improved catalytic performance in the MTG (methanol-to-gasoline) reaction [M. Bjorgen, F. Joensen, M.S. Holm, U. Olsbye, K.-P. Lillerud, S. Svelle, Appl. Catal. A 345 (2008) 43] was subjected to thorough examination using FTIR. Clearly, defects represented by internal Si-OH sites are removed upon NaOH treatment. In a parallel manner, free Si-OH sites increase in concentration and the results point to a selective mechanism for formation of mesopores as the framework dissolution preferentially takes place at defective sites in the crystallites. The acid properties of the desilicated materials were investigated by applying CO and collidine (2,4,6-trimethylpyridine) as molecular probes. Monitoring the induced frequency shifts upo...

2009-01-01

385

A pump-probe XFEL particle injector for hydrated samples  

CERN Document Server

We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.

2011-01-01

386

A Network Coding Approach to Loss Tomography  

CERN Document Server

Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of probe path selection. We discuss the ...

2010-01-01

387

Using Regulatory and Epistatic Networks to Extend the Findings of a Genome Scan: Identifying the Gene Drivers of Pigmentation in Merino Sheep  

UK PubMed Central (United Kingdom)

Extending genome wide association analysis by the inclusion of gene expression data may assist in the dissection of complex traits. We examined piebald, a pigmentation phenotype in both human and Merino...Full Text Available

388

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

389

The Prevalence of Concha Bullosa and Nasal Septal Deviation and Their Relationship to Maxillary Sinusitis by Volumetric Tomography  

UK PubMed Central (United Kingdom)

The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available

2010-01-01

390

TO: All GCN Notice recipients RE  

Science.gov (United States)

These sky images are scanned for point sources above a specified ... The threshold criteria are: a) Gold: >4 sigma in both the Soft AND Hard bands. b) Silver: ... Filtering: Currently, there is no plan for filtering within the GCN based ...

392

Structure of first- and second-stage mineralized elements in teeth of the sea urchin Lytechinus variegatus  

UK PubMed Central (United Kingdom)

Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass...Full Text Available

2009-12-01

393

Spacecraft and Instruments - NASA  

Science.gov (United States)

Aerosol Polarimetry Sensor (APS) + Continuous along-track scanning ... side of the spacecraft and faces outward, measures the intensity of incoming solar ... on a larger rocket, and faced slightly different conditions in spaceinto Glory wasn't ...

394

PrognoScan: a new database for meta-analysis of the prognostic value of genes  

UK PubMed Central (United Kingdom)

BackgroundIn cancer research, the association between a gene and clinical outcome suggests the underlying etiology of the disease and consequently can motivate further studies. The...Full Text Available

395

Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults  

UK PubMed Central (United Kingdom)

Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available

2010-03-01

396

Performance of a modified two-dimensional gamma scan system in spent fuel pin studies  

International Nuclear Information System (INIS)

This work assesses the performance of a modified two-dimensional gamma scan system in spent fuel pin studies. The techniques for a two-dimensional gamma scan studied have been developed at the Hot Cell of Institute of Nuclear Energy Research (INER). Samples are acquired from the spent fuel pin, TPC-SP-C1, which was irradiated in a commercial reactor core (the first of its kind in Taiwan) for 2 years and then deposited in a cooling pool for 10 years. The spent fuel pin was then transferred into INER for further examination. The gamma scanning system was driven by a step motor which had an accuracy within 0.1 mm in both X-Y directions. Data obtained from this system are presented in both an isotopic distribution and contour plot. Results in this study closely correspond to those in other investigations, thereby confirming the effectiveness of this modified system. (author)

1999-11-01

397

Optical sectioning of microbial biofilms.  

UK PubMed Central (United Kingdom)

Scanning confocal laser microscopy (SCLM) was used to visualize fully hydrated microbial biofilms. The improved rejection of out-of-focus haze and the increased resolution of SCLM made it preferable...Full Text Available

1991-10-01

398

Natural Gaits of the Non-Pathological Flat Foot and High-Arched Foot  

UK PubMed Central (United Kingdom)

There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static...Full Text Available

399

Morphology and Ultrastructure of Maternal Seed Tissues of Soybean in Relation to the Import of Photosynthate  

UK PubMed Central (United Kingdom)

Cytological observations were made on developing seeds of soybean (Glycine max (L.) Merr. “Amsoy 71”) using scanning and transmission electron microscopy and light microscopy....Full Text Available

1981-05-01

400

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

401

Limitations of Tc99m-MIBI-SPECT Imaging Scans in Persistent Primary Hyperparathyroidism  

UK PubMed Central (United Kingdom)

BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available

2011-01-01

402

Lameness, Activity Time-Budgets, and Estrus Expression in Dairy Cattle  

UK PubMed Central (United Kingdom)

The aim of the present study was to identify specific behavioral patterns that contribute to diminished estrus expression in lame cows. Behavioral scan and focal sampling were used to examine...Full Text Available

2008-12-01

403

Kaposi's sarcoma involving the thyroid in a patient with AIDS  

International Nuclear Information System (INIS)

A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.

404

Is energy imparted a good measure of the radiation risk associated with CT examinations  

International Nuclear Information System (INIS)

The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the ...

405

Genome-wide linkage scan for contraction velocity characteristics of knee musculature in the Leuven Genes for Muscular Strength Study  

UK PubMed Central (United Kingdom)

The torque-velocity relationship is known to be affected by ageing, decreasing its protective role in the prevention of falls. Interindividual variability in this torque-velocity relationship is partly...Full Text Available

2008-09-01

406

Gamuts in nuclear medicine  

Energy Technology Data Exchange (ETDEWEB)

This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.

1983-01-01

407

Facial osteomyelitis as complication of chronic sinusitis in hemophiliac-AIDS patients - scintigraphic evaluation with technetium-99m-MDP and Gallium-67; Osteomielitis da face como complicacao de sinusite cronica em hemofilicos aideticos - avaliacao cintilografica com {sup 99m} Tc-MDP e {sup 67} Ga  

Energy Technology Data Exchange (ETDEWEB)

In the paper six cases of facial osteomyelitis as a complication of chronic sinusitis in hemophiliac-AIDS patients are reported. Osteomyelitis was suggested by an increasing of erythrocyte sedimentation rate. The diagnosis was confirmed by a positive {sup 99m} Tc MDP scintigraphy. The patients were submitted to clinical treatment. The erythrocyte sedimentation rate and 67-gallium citrate scans were used in the follow-up of the therapy. Three patients had negative gallium after three weeks of organism-specific antibiotic therapy; in two patients the gallium scintigraphy remained positive. One patient did not undergo the radionuclide scan for this clinical conditions. These results suggest that MDP scans showed higher sensitivity and specificity in detection of bone disease in chronic sinusitis. Gallium scans appeared to be valuable tool in the follow-up of the infection. There are no reports in the ...

1997-01-01

408

Experimental Electron Heat Diffusion in TJ-II ECRH Plasmas  

Energy Technology Data Exchange (ETDEWEB)

Interpretative transport has been used to revisit the global scalings of TJ-II ECRH plasmas from a local perspective. Density, rotational transform and ERCH power scans were analysed based upon Thomson Scattering data (electron density and temperature) in steady state discharges. A simple formula to obtain the thermal conductivity, assuming pure diffusion and negligible convective heat fluxes was used in a set of 161 discharges. All the analysis was performed with the ASTRA transport shell. The density scan indicates that inside n=0,4 there is no significant change of e with density in the range studied (0.4 <ne>(1019m-3) 1.0), while in 0,5 <0,8 approximately, e decreases with density. In the rotational transform scan it is found that the values of e when a low order rational of the rotational transform is present locally seem to be smaller for the corresponding range, although it is apparent a general ...

2006-07-01

409

Electronic and Interfacial Properties of Pd/6H-SiC Schottky Diode ...  

Science.gov (United States)

and palladium silicides (Pd,Si) with a total. AES intensity ratio of Pd to Si of 35/65. Scanning Electron Microscopy. (SEM') of the Pd region shows that ...

410

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

411

Determination of Thermal Properties and Morphology of Eucalyptus Wood Residue Filled High Density Polyethylene Composites  

UK PubMed Central (United Kingdom)

Thermal behaviors of eucalyptus wood residue (EWR) filled recycled high density polyethylene (HDPE) composites have been measured applying the thermogravimetric analysis (TGA) and differential scanning...Full Text Available

412

Cobalt-57-bleomycin scanning of hila and mediastinum in patients with bronchial carcinoma: a prospective study.  

UK PubMed Central (United Kingdom)

Because the results with cobalt-57-bleomycin (57Co-bleo) as a tumour-seeking agent in patients with pulmonary tumours were promising, a prospective study was carried out to test the sensitivity and...Full Text Available

1976-12-01

413

Catheter Ablation for Paroxysmal Atrial Fibrillation  

Medline Plus

... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...

414

Calorimetric studies of the kinetic unfreezing of molecular motions in hydrated lysozyme, hemoglobin, and myoglobin.  

UK PubMed Central (United Kingdom)

Differential scanning calorimetric (DSC) studies of the glassy states of as-received and hydrated lysozyme, hemoglobin, and myoglobin powders, with water contents of < or = 0.25, < or...Full Text Available

1994-01-01

415

Calorimetric and spectroscopic studies of the polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines.  

UK PubMed Central (United Kingdom)

The polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines was investigated by differential scanning calorimetry, 31P-nuclear magnetic resonance, and Fourier...Full Text Available

1993-04-01

416

CLINICAL VALUE, NORMATIVE RETINAL SENSITIVITY VALUES, AND INTRASESSION REPEATABILITY USING A COMBINED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY/SCANNING LASER OPHTHALMOSCOPE MICROPERIMETER  

UK PubMed Central (United Kingdom)

PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available

2011-02-01

417

Atelectasis on pediatric chest CT: comparison of sedation techniques  

International Nuclear Information System (INIS)

Background. A change in practice at our institution resulted in increased use of anesthesia for CT scan of the chest in children who required sedation. Objective. To determine whether there is a difference in the frequency or severity of pulmonary atelectasis on CT scan in children sedated by anesthesiologists compared with children sedated by radiologists using intravenous pentobarbital. Materials and methods. Retrospective blinded review of 60 CT scans of the chest performed in 41 children. Forty-one studies in children sedated by radiologists (median age 29 months) were compared with 19 studies in children sedated by anesthesiologists (median age 25 months). Results. Atelectasis sufficient to obscure pulmonary metastases was shown in 5 of 41 (12 %) radiology sedations and 13 of 19 (68 %) anesthesiology sedations (P < 0.01). Higher grades of atelectasis were recorded in children under anesthesia (P < 0.01). ...

1999-07-01

418

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

419

An unusual presentation of metastatic adenocarcinoma of lung: a case report  

UK PubMed Central (United Kingdom)

We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available

420

Amorphous to crystalline phase transformation in Metglas reg-sign studied by Moessbauer spectroscopy  

International Nuclear Information System (INIS)

The authors present differential scanning calorimetry (DSC) and in situ Moessbauer spectroscopy results for Metglas ribbons, to which different heat treatments were made. The Curie temperature of the amorphous phase is determined and the evolution of the magnetic field of this phase is studied as a function of temperature

1997-12-01

421

A morphological and morphometric study of the prosimian lung: the lesser bushbaby Galago senegalensis.  

UK PubMed Central (United Kingdom)

The lung of the lesser bushbaby (Galago senegalensis) has been investigated morphologically and morphometrically using the transmission and scanning electron microscopes. Grossly and microscopically,...Full Text Available

1990-10-01

422

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

423

Scintigraphic detection of a radiologically equivocal fracture  

Energy Technology Data Exchange (ETDEWEB)

This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period.

1988-04-01

424

Scintigraphic detection of a radiologically equivocal fracture  

International Nuclear Information System (INIS)

This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period. (orig.).

425

Role of Surgery After Chemotherapy in B-Cell Lymphoma of Thymus Causing Airway Compression and Right Ventricle Outflow Tract Obstruction  

British Library Electronic Table of Contents (United Kingdom)

Primary B-cell lymphoma of thymus is uncommon. We describe the case of a 23-year-old woman with a history of shortness of breath and distended neck veins of 1-month duration. A chest roentgenogram and computed tomographic chest scan of the showed a large anterior mediastinal mass. Tru-cut biopsy revealed primary B-cell lymphoma of thymus. She underwent chemotherapy with no symptomatic improvement. Post-chemotherapy computed tomographic scan of the chest showed no appreciable reduction in tumor size. Surgical excision was carried out with excellent results.

2011-01-01

426

Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study  

British Library Electronic Table of Contents (United Kingdom)

There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.

2011-01-01

427

Beam position monitor readout and control in the SLC linac  

Energy Technology Data Exchange (ETDEWEB)

A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.

1985-04-01

428

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The ...

2007-07-01

429

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only ...

1991-01-01

430

A Simulation Study on a Radioactive Nuclide's Distribution within a Fuel rod by a Tomographic Gamma Scanning  

Energy Technology Data Exchange (ETDEWEB)

Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the characterization of several ...

2006-07-01

431

A Clinical Study on the Value of a Scoring System of the Scanning Images in Liver Cirrhosis  

International Nuclear Information System (INIS)

Although the radioisotope liver scan has primarily been of use in the detection of the intra-hepatic space occupying lesions, there has been an increasing awareness of its use in evaluation of liver function. In this study, the degree of hepatomegaly, changes in shape and mottling radiodensity on each lobe and splenic visualization in the liver scans done with colloidal radiogold were numerically expressed as scores under the arbitrary standard in 210 patients with liver cirrhosis. The clinical value of this scoring system was studied with special regards to the correlation between the radiogold hepatic uptake half time and conventional liver function tests. Following were the results; 1) The normal scan appeared in 6.7% of 210 patients with liver cirrhosis. 2) The colloidal radiogold hepatic uptake half time was abnormally and progressively prolonged in parallel to severity of hepatocellular dysfunction. The mean hepatic ...

1970-09-01

432

Vibrational population dynamics in liquids and glasses: IR pump-probe experiments from 10 K to 300 K  

Energy Technology Data Exchange (ETDEWEB)

The temperature dependent vibrational relaxation of the CO stretching mode of Rhodium dicarbonyl acetylacetonate (Rh(CO){sub 2}(acac)) and tungsten hexacarbonyl (W(CO){sub 6}) in dibutylphthalate (DBP) and 2-methylpentane (2-MP) were measured with IR pump and probe (P-P) experiments. The experiments were performed with {approximately}1.5 ps pulses generated by the Stanford superconducting accelerator pumped free electron laser (FEL). Measurements were performed on the Rh(CO){sub 2}(acac) CO asymmetric stretching mode at {lambda} = 4.98{mu}m from 10 K to 300 K. Both the parallel and magic angle probe polarizations decay curves are biexponential over the entire temperature range. The slow component (ranging from 40 ps at 300 K to 55 ps at 10K) is attributed to the population relaxations. For the fast component (ranging from 4-5 ps at 300 K to 13-15 ps at 10K), we propose a mechanism of spectral diffusion, in contrast to the previously proposed ...

1995-12-31

433

Thyroidal uptake of iodine-123 in children using a gamma camera and computer  

Energy Technology Data Exchange (ETDEWEB)

The measurement of thyroidal uptake of radioiodine using a gamma camera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.

1985-10-01

434

The Universal Dark Matter  

CERN Document Server

Fragile volatile aggregates with extremely low albedo, gravitationally drawn into the solar system are likely from the dark matter dominating the universal mass. Characteristics of this meteoric population permitted avoiding detection through a half-century's search. Measurements from space probes and in the upper atmosphere prove their existence and confirm their elusive properties.

2006-01-01

435

The Fenton oxidation mechanism: reactivities of biologically relevant substrates with two oxidizing intermediates differ from those predicted for the hydroxyl radical.  

UK PubMed Central (United Kingdom)

The application of kinetic probes that allow one to determine relative reactivities of biologically relevant substrates with oxidizing intermediates in the Fenton reagent (H2O2 plus Fe2+ in acidic aqueous...Full Text Available

1994-07-05

436

The Cause of an Eddy Current Signal Noise from a Steam Generator Tube and its Effect on the Detectability of a Crack  

International Nuclear Information System (INIS)

An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current probe from manufacturing anomalies, the ...

2008-05-01

437

Single Atom Detection With Optical Cavities  

CERN Document Server

We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.

2008-01-01

438

Radon in soil gas survey in Curitiba (Brazil)  

International Nuclear Information System (INIS)

This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air ...

2002-10-08

439

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

440

Radial distribution functions of amorphous silicon  

Energy Technology Data Exchange (ETDEWEB)

Substantial changes in the radial distribution function of amorphous Si films have been observed in neutron-diffraction studies. The spectra indicate changes in short-range order associated with an approx.11% modification in the bond-angle distribution width. The results allow the first direct comparison of structural and vibrational Raman probes of variations in local order in thin-film amorphous solids. Good agreement is obtained between the measured bond-angle variation and that based on Raman estimates.

1989-03-15

441

Platinum(II) complexes as spectroscopic probes for biomolecules  

Energy Technology Data Exchange (ETDEWEB)

The use of platinum(II) complexes as tags and probes for biomolecules is indeed advantageous for their reactivities can be selective for certain purposes through an interplay of mild reaction conditions and of the ligands bound to the platinum. The use of {sup 195}Pt NMR as a method of detecting platinum and its interactions with biomolecules was carried out with the simplest model of platinum(II) tagging to proteins. Variable-temperature {sup 195}Pt NMR spectroscopy proved useful in studying the stereodynamics of complex thioethers like methionine. The complex, Pt(trpy)Cl{sup +}, with its chromophore has a greater potential for probing proteins. It is a noninvasive and selective tag for histidine and cysteine residues on the surface of cytochrome c at pH 5. The protein derivatives obtained are separable, and the tags are easily quantitated and differentiated through the metal-to-ligand charge transfer bands which are sensitive to the ...

1990-09-21

442

Movable genetic elements: detection of changes in maize DNA at the Shrunken locus due to the intervention of Ds elements  

Science.gov (United States)

This report describes our initial attempts at the molecular characterization of a maize controlling element. We have prepared a cDNA probe and used it to detect changes at a locus where Ds elements are found. Evidence of their presence are indicated by changes in the restriction patterns, but there is as yet no information on the physical nature of the controlling elements nor on the kinds of rearrangements they cause.

1980-05-28

443

Lagrangian analysis of contaminant dispersal in bounded turbulent shear flows  

Energy Technology Data Exchange (ETDEWEB)

Methods of solving Navier-Stokes equations for turbulent channel flow are given. These numerical solutions utilize either Neumann or Dirichlet boundary conditions. Computer codes were written and tested and are discussed. Digital image processing of flow visualization video sequences, taken simultaneously with vorticity probe measurements in a turbulent boundary layer, were carried out. 4 figs. (GHH)

1991-01-01

444

Isolation, sequence, and expression in Escherichia coli of an unusual thioredoxin gene from the cyanobacterium Anabaena sp. strain PCC 7120.  

UK PubMed Central (United Kingdom)

Two sequences with homology to a thioredoxin oligonucleotide probe were detected by Southern blot analysis of Anabaena sp. strain PCC 7120 genomic DNA. One of the sequences was shown to code for a protein...Full Text Available

1989-01-01

445

High-resolution primary ion beam probe for SIMS  

Energy Technology Data Exchange (ETDEWEB)

High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.

2004-06-15

446

High throughput protein fold identification by using experimental constraints derived from intramolecular cross-links and mass spectrometry  

UK PubMed Central (United Kingdom)

We have used intramolecular cross-linking, MS, and sequence threading to rapidly identify the fold of a model protein, bovine basic fibroblast growth factor (FGF)-2. Its tertiary structure was probed...Full Text Available

2000-05-23

447

Fusion of GFP to the M.EcoKI DNA methyltransferase produces a new probe of Type I DNA restriction and modification enzymes  

UK PubMed Central (United Kingdom)

AbstractWe describe the fusion of enhanced green fluorescent protein to the C-terminus of the HsdS DNA sequence-specificity subunit of the Type I DNA modification methyltransferase M.EcoKI....Full Text Available

2010-07-23

448

Electroweak symmetry breaking at photon colliders  

Energy Technology Data Exchange (ETDEWEB)

The electroweak-symmetry-breaking sector of the standard model can be weakly-coupled or can be strongly-coupled, which is characterized by some kinds of strong interaction among the Goldstone bosons of the electroweak-symmetry-breaking sector. In this paper, we summarize an investigation of probing the strong electroweak-symmetry-breaking effects at photon colliders. ((orig.)).

1995-02-01

449

Electroweak symmetry breaking at photon colliders  

International Nuclear Information System (INIS)

The electroweak-symmetry-breaking sector of the standard model can be weakly-coupled or can be strongly-coupled, which is characterized by some kinds of strong interaction among the Goldstone bosons of the electroweak-symmetry-breaking sector. In this paper, we summarize an investigation of probing the strong electroweak-symmetry-breaking effects at photon colliders. ((orig.)).

450

Eddy current signal analysis techniques for assessing degradation of support plate structures in nuclear steam generators  

Energy Technology Data Exchange (ETDEWEB)

The steam generator (SG) is one of the most critical components of the heat transfer system in nuclear generation stations. Testing the structural integrity of SG tubing and SG internals is a key element of the fitness-for-service assessments to assure the safe and continuous operation of nuclear power plants. Recent eddy current (ET) inspections of two nuclear power plants revealed degradation of some of the tube support plate (TSP) structures, which was also confirmed by visual inspection. The phenomena was described as metal loss, caused by flow-accelerated corrosion of the carbon steel trefoil support plate and varying from minor to complete loss of the ligaments. This loss of TSP ligaments results in lack of support for the adjacent tubes making them more susceptible to fretting-wear damage and fatigue cracking. A signal analysis method, based on the responses at low frequency of two types of eddy current probes, has been developed to assess the degree of ...

2006-07-01

451

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

452

Development of video probe system for inspection of feeder pipe support in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post- Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And untrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughlv because of narrow and confined accessibility, that is, an inspection space between the pressure tube channels is less than 100mm and pipes in feederpipe support area are congested. And also, workers involved in inspecting feederpipe support area ...

2000-07-01

453

Design, synthesis, and testing of difluoroboron derivatized curcumins as near infrared probes for in vivo detection of amyloid-? deposits  

UK PubMed Central (United Kingdom)

Amyloid-β (Aβ) deposits have been identified as key players in the progression of Alzheimer’s disease (AD). Recent evidence indicates that the deposits probably precede...Full Text Available

2009-10-28

454

Cloning of rice DNA and identification of tRNA gene clones  

Energy Technology Data Exchange (ETDEWEB)

DNA from 48 hr germinated rice embryos was cut with restriction endonuclease Bam H1 and cloned to the Bam H1 site on plasmid pBR 322. The clones containing recombinant DNA were selected by their sensitivity to tetracycline and resistance to ampicillin. Using /sup 32/P-labelled rice embryos tRNA as a probe two clones were identified to contain tRNA genes by colony hybridization.

1981-10-20

455

Aluminum hydroxide coating thickness measurements and brushing tests on K West Basin fuel elements  

Energy Technology Data Exchange (ETDEWEB)

Aluminum hydroxide coating thicknesses were measured on fuel elements stored in aluminum canisters in K West Basin using specially developed eddy current probes . The results were used to estimate coating inventories for MCO fuel,loading. Brushing tests successfully demonstrated the ability to remove the coating if deemed necessary prior to MCO loading.

1998-09-11

456

Activation and Stiffness of the Inhibited States of F1-ATPase Probed by Single-molecule Manipulation  

UK PubMed Central (United Kingdom)

F1-ATPase (F1), a soluble portion of FoF1-ATP synthase (FoF1), is an ATP-driven motor in which γϵ subunits rotate in...Full Text Available

2010-04-09

457

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

458

A legal-historical consideration of links between Canadian and South African racial policies  

British Library Electronic Table of Contents (United Kingdom)

Significant recent writings have suggested strong parallels and actual links between the historical legal architectures of Canadian Aboriginal policy and South African apartheid. This article's further probing of these claims shows them to be very doubtful. At the same time, some more limited legal parallels between the two systems shows the importance of undertaking further analysis of the transmission and exchange of legal ideas and norms within the Commonwealth order.

2010-01-01

459

5'-Azido-[3,6-3H2]-1-napthylphthalamic acid, a photoactivatable probe for naphthylphthalamic acid receptor proteins from higher plants: identification of a 23-kDa protein from maize coleoptile plasma membranes.  

UK PubMed Central (United Kingdom)

1-Naphthylphthalamic acid (NPA) is a specific inhibitor of polar auxin transport that blocks carrier-mediated auxin efflux from plant cells. To allow identification of the NPA receptor thought to be...Full Text Available

1992-01-15

460

Shape evolution of nanostructures by thermal and ion beam processing. Modeling and atomistic simulations  

International Nuclear Information System (INIS)

Single-crystalline nanostructures often exhibit gradients of surface (and/or interface) curvature that emerge from fabrication and growth processes or from thermal fluctuations. Thus, the system-inherent capillary force can initiate morphological transformations during further processing steps or during operation at elevated temperature. Therefore and because of the ongoing miniaturization of functional structures which causes a general rise in surface-to-volume ratios, solid-state capillary phenomena will become increasingly important: On the one hand diffusion-mediated capillary processes can be of practical use in view of non-conventional nanostructure fabrication methods based on self-organization mechanisms, on the other hand they can destroy the integrity of nanostructures which can go along with the failure of functionality. Additionally, capillarity-induced shape transformations are effected and can thereby be controlled by applied fields and forces (guided or driven ...

2009-05-12

461

Special phased array applications for pipeline girth weld inspections  

Energy Technology Data Exchange (ETDEWEB)

Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for ...

2004-07-01

462

Prospective evaluation of femoral head viability following femoral neck fracture  

International Nuclear Information System (INIS)

The bone scans of 33 patients (pts) with recent subcapital fractures (fx) of the femur were evaluated prospectively to determine their value in predicting femoral head visability. Each of the 33 pts (ll men, 22 women, age range 30-92) had a pre-operative bone scan within 72 hrs of the fx (23 pts within 24 hrs). Anterior and posterior planar views of both hips and pinhole views (50% of pts) were obtained 2 hrs after administration of Tc-99m HDP. The femoral head was classified as perfused if it showed the same activity as the opposite normal side or if it showed only slightly decreased activity. Femoral heads showing absent activity were classified as nonperfused. Overall, 20 of the 33 pts showed a photopenic femoral head on the side of the fx. Only 2 pts showed increased activity at hte site of the fx. Internal fixation of the fx was performed in 23 pts, 12 of whom had one or more follow-up scans. Five of these 12 pts ...

1984-06-05

463

Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, covering lung apex ...

1990-01-01

464

CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice  

Energy Technology Data Exchange (ETDEWEB)

Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: ...

1992-07-15

465

CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice  

International Nuclear Information System (INIS)

Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: ...

1992-07-01

466

Time-domain dynamic opto-rheology study of polymer films using step-scan FTIR time-resolved spectroscopy (S{sup 2}FTIR TRS)  

Energy Technology Data Exchange (ETDEWEB)

Step-scan Fourier transform infrared spectroscopy in conjunction with impulse stress on polymer films has been used to monitor dynamic rheological responses in real time. A novel piezo-electrically-driven polymer microrheometer was employed to apply repetitive impulses to the polymer sample while time-domain spectra were recorded. Recent results include the study of both semi-crystalline polymers such as isotactic polypropylene (iPP) and elastomers such as Estane polyester/polyurethane copolymer and Kraton tri-block copolymer. The spectral changes of iPP are consistent with frequency-domain results. For iPP at room temperature, large differences in the response times of different absorption bands are not seen. However, the orientation response of the CH{sub 3} rocking mode is slightly slower than the responses of the backbone modes. To the authors` knowledge, this is the first reported successful step-scan FTIR time-domain dynamic polymer ...

1998-07-01

467

The uterine blush. A potential false-positive in Meckel's scan interpretation  

Energy Technology Data Exchange (ETDEWEB)

To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. ...

1982-10-01

468

The measurement of the fission product ratios, {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuel by gamma scanning method  

Energy Technology Data Exchange (ETDEWEB)

We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.

1997-10-01

469

The measurement of the fission product ratios, "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuel by gamma scanning method  

International Nuclear Information System (INIS)

We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.

1988-09-18

470

Position of nuclear-medical techniques for evaluation of loosened total hip endroprostheses  

Energy Technology Data Exchange (ETDEWEB)

For diagnosis of loosening or infection after implantation of a single-side or double-side total hip endoprosthesis 59 patients being in pain were investigated by a combination of bone scan (Technetium-99m DPD) and leucocyte scan (Indium-111 labelled leucocytes). The correlation between clinical results and scintigraphic findings revealed: bone scintigraphy detects loosening of prostheses with 95% sensitivity (45/47); bone scintigraphy excludes an instable prosthesis with 89% specificity (3/27). 45% of the loosened prostheses revealed an infection (21/47): leucocyte scintigraphy could detect 17 correct positive. Three leucocyte scans of 53 prostheses without clinical signs of infection were false positive. Therefore, leucocyte scintigraphy had a sensitivity of 91% and a specificity of 94% for detecting infection. Bone scintigraphy can detect loosening of prostheses with 93% accuracy, Indium-111 labelled leucocyte ...

1985-10-01

471

Lipiodol-CT findings of hepatocellular carcinoma: Correlation with lipiodol accumulation pattern and serum AFP  

Energy Technology Data Exchange (ETDEWEB)

Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol better. 4. Lipiodol-CT was superior to ...

1989-12-15

472

Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin  

Energy Technology Data Exchange (ETDEWEB)

The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled ...

1990-12-01

473

High Throughput Screening for the Discovery of More Efficient Catalysts for Emissions Control  

Energy Technology Data Exchange (ETDEWEB)

High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing ...

2004-03-31

474

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

475

Dimensionless energy confinement scaling in W7-AS  

International Nuclear Information System (INIS)

Energy confinement in W7-AS has been analyzed in terms of dimensionally exact form free functions employing Bayesian probability theory. The confinement function was set up as a linear combination of dimensionally exact power law terms as already proposed very early by Connor and Taylor. Generation of this expansion basis is dictated by the basic plasma model which one assumes. Based upon data accumulated in W7-AS, which contains the energy content for a wide variety of variable settings, predictions for single variable scans are made. The scaling functions for density and power scans, respectively, are in quantitative agreement with data collected in W7-AS. The result of a single variable scan is therefore already hidden in the data obtained for arbitrary variable choices and can be extracted from the latter by a proper data analysis. Furthermore, the optimal model for the description of the global transport in W7-AS is ...

1999-12-01

476

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...

1981-01-01

477

Computed Tomography in pulmonary cystic fibrosis  

International Nuclear Information System (INIS)

This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method than conventional radiography to identify and locate the signs of pulmonary CF. The early identification ...

1991-01-01

478

Circulation, bone scans, and tetracycline labeling in microvascularized and vascular bundle implanted rib grafts  

Energy Technology Data Exchange (ETDEWEB)

The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft revascularization. The circulation in rib grafts was accurately reflected in technetium 99 bone scans, as was the patency of the anastomoses of microvascularized ...

1984-11-01

479

3-dimensional observations of atmospheric variables during the field campaign COPS  

Energy Technology Data Exchange (ETDEWEB)

The Convective and Orographically-induced Precipitation Study (COPS) has the aim to advance the quality of forecasts of orographically-induced precipitation in complex terrain. COPS is a Research and Development Project of the World Weather Research Program and considered to be one of the largest field campaigns on quantitative precipitation forecasting that has been performed so far. A network of state-of-the-art active and passive remote sensing systems was combined with in total 10 airborne platforms, Meteosat rapid scans and dense networks of standard meteorological instruments during the three months long field phase (June-August, 2007) in south-western Germany/eastern France to observe atmospheric variables in the three spatial dimensions and in time. By the University of Hohenheim, two novel ground-based mobile scanning lidar systems were deployed: a scanning rotational Raman lidar which provides combined ...

2008-05-01

480

[75Se]Selenomethionine scanning for parathyroid localization should be abandoned  

International Nuclear Information System (INIS)

Image subtraction techniques, in conjunction with [75Se]selenomethionine (75Se) scintigraphy, have recently been suggested to be a potentially valuable tool for localization of parathyroid abnormalities. With use of these techniques, we prospectively studied 15 patients scheduled for parathyroid operations. Postoperatively, all were normocalcemic. Anterior scintiscans of the neck were divided into quadrants, and regions of enhanced uptake were assigned to one or more quadrants. On this basis, by chance alone a minimum of 25% of single-gland enlargements would be assigned to the correct quadrant of the neck. We found that by use of 75Se scanning only 8 of 22 abnormal glands (36%) were assigned to the quadrant of the neck in which they were found intraoperatively. In no case was a clearly visualized focus of parathyroid activity encountered. These results do not justify the continued use of 75Se scintigraphy with or without image subtraction in the preoperative ...

481

Subdural effusions in children under two years. Clinical and computer-tomographical data  

Energy Technology Data Exchange (ETDEWEB)

We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 clinical symptoms highly diagnostic of subdural effusions.

1980-05-01

482

Precise measurement of a focused ion beam profile  

Energy Technology Data Exchange (ETDEWEB)

The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.

1987-06-01

483

Mechanism of filler action in reducing the wear of PTFE polymer by differential scanning calorimetry  

British Library Electronic Table of Contents (United Kingdom)

Two types of representative nanometer materials, i.e., fibroid nanometer attapulgite and approximate spherical ultrafine diamond, were selected as fillers of polytetrafluoroethylene (PTFE) to study the mechanism of the wear-reducing actions of the fillers in PTFE composites. The friction and wear tests were performed on a block-on-ring wear tester under dry sliding conditions. Differential scanning calorimetry (DSC) was used to investigate material microstructure and to examine modes of failure. No significant change in coefficient of friction was found, but the wear rate of PTFE composites was orders of magnitude less than that of pure PTFE. DSC analysis revealed that nanometer attapulgite and ultrafine diamond played a heterogeneous nucleation role in PTFE matrix and consequently resulte...

2007-01-01

484

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system; Interventionelle MR-Tomographie: Klinische Erfahrungen mit einem 1,5 Tesla System  

Energy Technology Data Exchange (ETDEWEB)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)

1997-05-01

485

Fuel element powers, STVU masses, and burnups from gamma-scanning data: Preliminary analysis of irradiated ORR (Oak Ridge Research Reactor) LEU fuel elements  

Energy Technology Data Exchange (ETDEWEB)

Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.

1988-01-01

486

Focused ion beam sculpting curved shapes.  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) is used to accurately sculpt predetermined micron-scale, curved shapes in a number of solids. Using a digitally scanned ion beam system, various features are sputtered including hemispheres and sine waves having dimensions from 1-50 {micro}m. Ion sculpting is accomplished by changing pixel dwell time within individual boustrophedonic scans. The pixel dwell times used to sculpt a given shape are determined prior to milling and account for the material-specific, angle-dependent sputter yield, Y({theta}), as well as the amount of beam overlap in adjacent pixels. A number of target materials, including C, Au and Si, are accurately sculpted using this method. For several target materials, the curved feature shape closely matches the intended shape with milled feature depths within 5% of intended values.

2005-02-01

487

Finite element analysis of a scanning x-ray microscope micropositioning stage  

Energy Technology Data Exchange (ETDEWEB)

A micropositioning stage for use with an x-ray microscope has been developed to scan samples over a 100 {mu}m{times}100-{mu}m area with a resolution of 100 A. The stage employs flexure hinges driven by piezoelectric actuators to achieve this high positioning accuracy. Due to the severe geometry of the hinges, stresses and deflections are determined (via finite element methods) to ensure a credible design. Since the stage is to be used in a stepping capacity, natural frequencies are computed to identify resonant conditions which could potentially cause excessive deflections. The finite element models show that the stage responds like a discrete lumped-mass system for the lower modes, and a continuous system with flexural characteristics for the higher modes.

1992-01-01

488

Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry  

British Library Electronic Table of Contents (United Kingdom)

Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...

2010-01-01

489

Electron beam, ion beam, X-ray optical techniques for fabricating surface-acoustic-wave and thin-film optical devices  

International Nuclear Information System (INIS)

Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.

490

Electrical properties of focused-ion-beam boron-implanted silicon  

International Nuclear Information System (INIS)

Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).

491

Effects of carbon fiber surface treatment on the friction and wear behavior of 2D woven carbon fabric/phenolic composites  

British Library Electronic Table of Contents (United Kingdom)

To improve the friction and wear behavior of carbon fabric reinforced polymer composites (CFRP), nano-SiO2 was deposited on the fabric surface. The friction and wear behavior of the resulting composites were investigated on a model ring-on-block test rig. Experimental results revealed that fiber surface treatment contributed to largely improve the tribological properties of the CFRP composites. Scanning electron microscope (SEM) investigation showed that the worn surface of the surface modified CFRP composite was smoother under given load and sliding rate. Field emission scanning electron microscopy (FESEM), FTIR and X-ray photoelectron spectroscopy (XPS) studies of the carbon fiber surface showed that nanostructured Sio2 thin film can be obtained by SiO2 sols deposition, which improved th...

2009-01-01

492

Development and application of gamma scanning technology for on-line investigation of industrial process columns and vessels  

International Nuclear Information System (INIS)

Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)

1998-10-30

493

Chemical, electrical and electrochemical characterization of hybrid organic/inorganic polypyrrole/PW12O40^3^- coating deposited on polyester fabrics  

British Library Electronic Table of Contents (United Kingdom)

A study of the stability of conducting fabrics of polyester (PES) coated with polypyrrole/PW12O40^3^- (organic/inorganic hybrid material) in different pH solutions (1, 7, 13) has been done. Washing tests were also done in views of its possible application in electronic textiles such as antistatic clothing. X-ray photoelectron spectroscopy (XPS) studies have been done to quantify the amount of counter ion that remains in the polymer matrix and determine the doping ratio (N^+/N) after the different tests. Scanning electron microscopy (SEM) was also used to observe morphological differences after the different tests. Surface resistivity changes were measured by means of electrochemical impedance spectroscopy (EIS). Scanning electrochemical microscopy (SECM) was employed to measure changes in ...

2011-01-01

494

Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics  

International Nuclear Information System (INIS)

Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion.

495

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

496

Applications of environmental scanning electron microscopy (ESEM) in the study of novel drying latex films  

Energy Technology Data Exchange (ETDEWEB)

We have employed Environmental Scanning Electron Microscopy (ESEM) and Energy Dispersive X-ray (EDX) analysis to study the microstructural evolution of acrylic latex stabilised with a novel polysaccharide derived from agricultural waste. The analysis revealed that the micro structure of the latex in the 'wet' state consists of individual particles and clusters. Upon evaporation a discontinuous film is formed, with voids present within its structure, which is inconsistent with the conventional descriptions of film formation. Further ESEM examination of 'dry' specimens revealed that aging resulted in the formation of dendritic structures on the surfaces of the latex films, which EDX analysis confirmed to have been formed via crystallisation of salt. The experimental evidence suggests that the clusters, which are part of the structure of the latex, may act as nucleation centres that would allow the dendrites to form.

2008-08-15

497

A novel gamma scanning system for on-line diagnostic inspection of industrial process columns  

International Nuclear Information System (INIS)

A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)

498

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

499

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.