WorldWideScience
1

Development of nanometer resolution C-Band radio frequency beam position monitors in the Final Focus Test Beam  

Energy Technology Data Exchange (ETDEWEB)

Using a 47 GeV electron beam, the Final Focus Test Beam (FFTB) produces vertical spot sizes around 70 nm. These small beam sizes introduce an excellent opportunity to develop and test high resolution Radio Frequency Beam Position Monitors (RF-BPMs). These BPMs are designed to measure pulse to pulse beam motion (jitter) at a theoretical resolution of approximately 1 nm. The beam induces a TM{sub 110} mode with an amplitude linearly proportional to its charge and displacement from the BPM's (cylindrical cavity) axis. The C-band (5,712 MHz) TM{sub 110} signal is processed and converted into beam position for use by the Stanford Linear Collider (SLC) control system. Presented are the experimental procedures, acquisition, and analysis of data demonstrating resolution of jitter near 25 nm. With the design of future e{sup +}e{sup -} linear colliders requiring spot sizes close to 3 nm, understanding ...

1998-08-01

2

An automated procedure for detecting protein folds from sub-nanometer resolution electron density  

UK PubMed Central (United Kingdom)

The use of sub-nanometer resolution electron density as spatial constraints for denovo and ab-initio structure prediction requires knowledge of protein boundaries...Full Text Available

2010-06-01

3

Micro-strip metal foil detectors for the beam profile monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.

2005-07-01

4

Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into ...

2011-06-22

5

Tunable single-wavelength semiconductor lasers  

Energy Technology Data Exchange (ETDEWEB)

This dissertation deals with both the theoretical and the technological aspects of monolithic tunable lasers, and the experimental techniques for opto-electronic integration. In the theoretical part, the principles and limitations of wavelength tuning and spectral linewidth reduction in monolithic semiconductor lasers are described, with coupled distributed feedback-Fabry Perot (DFB-FP) lasers and long DFB lasers as examples. Stepwise tuning of wavelength over tens of nanometers and continuous tuning over the range of a mode spacing are shown to be possible. Spatial hole burning is found to affect the spectral linewidth of lasers involving strong active gratings. On the technological side, one of the major issues is the fabrication of flexible gratings. Direct-writing techniques, such as focused ion beam (FIB) implantation and e-beam lithography, provide the resolution, flexibility and accuracy that conventional holographic lithography lacks. ...

1988-01-01

6

Microstructural features in sintered Si_3N_4/SiC platelets systems  

International Nuclear Information System (INIS)

Analytical TEM and high resolution TEM were used in the microstructural characterization of hot-press sintered Si_3N_4-SiC platelets composites. The quantity of sintering additives, Er_2O_3 and AlN, was varied to produce different matrices, e. g. Si_3N_4, #beta#'+#alpha#'-Sialon and #alpha#'-Sialon. Detailed analysis of platelet-sialon matrix interfaces revealed the presence of AlN polytypoids. The polytypoids nucleate preferentially onto the (0001) plane of SiC and growth epitaxially in several ten nanometer layers contributing in this way to crystallize, partially, the matrix intergranular glass pockets contacting the platelets. Possible applications of the phenomena to microstructural control, grain boundary phase control and enhanced creep resistance are discussed. (orig.).

1993-10-04

7

Beam position monitor sensitivity for low-[beta] beams  

Energy Technology Data Exchange (ETDEWEB)

Design of a beam position monitor (BPM) which is sensitive to low velo charged particle beams is considered. Quantitative estimates are made for the corrections to the conventional approximations to solutions of the Laplace Equation in two-dimensions when a BPM is used to measure to position of low velocity (low-[beta]) beams. (AIP)

1994-10-10

8

X-ray microanalysis of Al/Zr multilayers in the transmission electron microscope  

International Nuclear Information System (INIS)

A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer ...

1997-04-04

9

Functionalizing titania nanoparticle surfaces in a fluidized bed plasma reactor  

International Nuclear Information System (INIS)

Functionalizing nanoparticle surfaces is essential for achieving homogeneous dispersions of monodisperse particles in polymer nanocomposites for successful utilization in engineering applications. Functionalization reduces the surface energy of the nanoparticles, thereby limiting the tendency to agglomerate. Moreover, reactive groups on the surface can also participate in the polymerization, creating covalent bonds between the inorganic and organic phases. In this paper, a fluidized bed inductively coupled plasma (FB-ICP) reactor is used to break apart the agglomerates and functionalize commercial TiO2 nanoparticle powders in a batch of several grams. The fluidized bed could be implemented into a continuous flow reactor, potentially making this a viable method to treat larger quantities of commercial powders. The particles are treated with acrylic acid (AA) and tetraethylorthosilicate (TEOS) plasma and the functionalized particles were collected separately from bulk powder. High ...

2009-11-18

10

Fabrication of nanometer structures by means of a fine-focused ion beam  

International Nuclear Information System (INIS)

Focused Ion Beams are an important approach for nanostructure fabrication in the semiconductor industry and material sciences. Applications in sputtering and ion induced deposition of materials are investigated. The IMSA FIB system equipped with the high resolution Orsay Physics CANION M31plus ion column with current densities up to 10 A/cm"2 including a gas injection system is applied. In this work the ion beam induced chemical vapour deposition of tungsten, wherefore tungsten hexacarbonyl as precursor gas is used for a first investigation. Conductive tungsten-nanowires with smallest cross-section upon a substrate of Si and SiO_2 are produced. The ion beam parameters of this focused ion beam system are optimized for the metal deposition. A short insight in the theory of layer nucleation and growth induced by the ion beam during the metal deposition is given. The layer quality is determined by Auger electron analysis which shows the components in atomic percent ...

2000-03-01

12

Focused ion beam assisted three-dimensional rock imaging at submicron scale  

Energy Technology Data Exchange (ETDEWEB)

Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 micrometers and as thin as 100 nanometers by sputtering of atoms from the sample surface. The focused ion beam, consisting of gallium ions (Ga+) ...

2003-05-09

13

Real World Evaluation of Dual-Zone ICD and CRT-D Programming Compared to Single-Zone Programming: The ALTITUDE REDUCES Study  

British Library Electronic Table of Contents (United Kingdom)

Tachycardia Detection, ICD, CRT-D Devices, Appropriate and Inappropriate Shock.-Introduction: We evaluated the frequency of appropriate and inappropriate shocks and survival in patients using dual-zone programming versus single-zone programming. Methods and Results: For the ALTITUDE REDUCES study, patients were followed for 1.6 1.1 years. The 12-month incidence of any shock was lower for dual-versus single-zone programmed detection at rates -170 bpm and between 170-200 bpm (P < 0.001). Appropriate shock rates at 1 year were also lower with dual-zone programming in these rate intervals (single zone 9.1%, 5.4%, P < 0.001, dual zone 6.7%, 4.7%, P < 0.02). There were no detectable differences between single- and dual-zone shock incidence at detection rates - 200 bpm (P = 0.14). Inappropriate s...

2011-01-01

14

ETHERNET BASED EMBEDDED SYSTEM FOR FEL DIAGNOSTICS AND CONTROLS  

Energy Technology Data Exchange (ETDEWEB)

An Ethernet based embedded system has been developed to upgrade the Beam Viewer and Beam Position Monitor (BPM) systems within the free-electron laser (FEL) project at Jefferson Lab. The embedded microcontroller was mounted on the front-end I/O cards with software packages such as Experimental Physics and Industrial Control System (EPICS) and Real Time Executive for Multiprocessor System (RTEMS) running as an Input/Output Controller (IOC). By cross compiling with the EPICS, the RTEMS kernel, IOC device supports, and databases all of these can be downloaded into the microcontroller. The first version of the BPM electronics based on the embedded controller was built and is currently running in our FEL system. The new version of BPM that will use a Single Board IOC (SBIOC), which integrates with an Field Programming Gate Array (FPGA) and a ColdFire embedded microcontroller, is presently under development. The new system has ...

2006-10-24

15

The systemic perspective of service processes: underlying theory, architecture and approach  

British Library Electronic Table of Contents (United Kingdom)

As competition in the service industry grows, delivering high-quality service to meet customers' needs and expectations becomes paramount. In order to achieve a thorough understanding of customers, companies are increasingly adopting Customer Relationship Management (CRM) initiatives. However, CRM does not have the process vision necessary to cope with complex and cross-functional processes. This problem is better handled by Business Process Management (BPM) initiatives, which, by their turn, struggle to built-in customer intelligence in their systems. Based upon systems theory, we discuss the roles of CRM and BPM in an integrated approach to deliver customer fulfillment. As the evolution of service-oriented approaches requires us to consider both customer interactions and experiences as k...

2008-01-01

16

The new Tevatron beam position monitor front-end software  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron is a proton anti-proton accelerator collider operating at the Fermi National Accelerator Laboratory. The machine is currently delivering beam for the CDF and D0 experiments, which expect increasing luminosity until the conclusion of Run II, planned for 2009. The Laboratory defined a plan for achieving higher luminosity, and one of the tasks is the upgrade of the accelerator's beam position monitor (BPM). The Tevatron was built during the early eighties and some of its control systems, including the BPMs, are still the original ones. This paper describes the front-end software of the Tevatron BPM upgrade, from the requirements to the implementation, and the underlying hardware setup. The front-end software designed is presented, emphasizing its modularity and reusability, allowing it to be applied to other Fermilab machines.

2005-05-01

17

Sample method for formation of nanometer scale holes in membranes  

Energy Technology Data Exchange (ETDEWEB)

When nanometer scale holes (diameters of 50 to a few hundred nm) are imaged in a scanning electron microscope (SEM) at pressures in the 10{sup -5} to 10{sup -6} torr range, hydrocarbon deposits built up and result in the closing of holes within minutes of imaging. Additionally, electron beam deposition of material from a gas source allows the closing of holes with films of platinum or TEOS oxide. In an instrument equipped both with a focused ion beam (FIB), and an SEM, holes can be formed and then covered with a thin film to form nanopores with controlled openings, ranging down to only a few nanometers.

2003-02-24

18

Mechanism of Methanes Adsorption on Nanometer Active Carbon at Supercritical State  

British Library Electronic Table of Contents (United Kingdom)

Isosteric heats and adsorption isotherms of methane on nanometer active carbon were measured at supercritical temperature (273-373 K) and pressure from 0 to 10 MPa. The measured data agreed well with Dubinin-Astakhov (DA) model at lower pressure but failed when pressure exceeded a special range. General Freundlich (GF) equation was used to modify the DA equation at high pressure and thus formed a combined bisection model GFDA. The adsorption mechanism of methane on nanometer active carbon was raised according to GFDA model and the heterogeneous energy distribution of the adsorbent was analyzed.

2008-01-01

19

Microstructure and emission properties of nanometer Ce-W material  

International Nuclear Information System (INIS)

Nanometer Ce-W composite materials have been prepared by the method of freeze-drying. Microstructure and surface properties of materials were investigated by SEM and 'in situ' AES and emission characteristics have been determined. It is found that the nanometer materials have relatively small crystal particles with average dimensions in the order of 50 nm. Due to the results of matrix analysis, the cerium in the materials is uniformly distributed on submicron scale, which proves that the diffusion ability of cerium has been increased. Under high temperature, the active layer on the surface thickens simultaneously with the increase of cerium and oxygen. As a result, nanometer Ce-W materials exhibit excellent emission characteristics compared with those of micron-sized Ce-W materials.

2007-07-12

20

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

21

Neutron reflectometry study of surface segregation in an isotopic poly(ethylene propylene) blend : deviation from mean field theory.  

Energy Technology Data Exchange (ETDEWEB)

Neutron reflectometry (NR) was used to measure the concentration profile of a symmetric PEP/dPEP polymer blend with nanometer-scale resolution in the one-phase region. The shape of the profile near the surface was found to differ significantly from mean-field theory predictions for all bulk concentrations and temperatures surveyed. The profile shape is flattened at the surface over a distance about half the bulk correlation length, a length scale far greater than that of the dispersive forces that are the dominant microscopic interaction in such blends. We introduce a new method for extracting the surface energy difference that drives segregation based on the Gibbs adsorption equation (GAE) and compare it to a previous method based on mean-field theory. While both methods produce qualitatively similar results (the surface energy of pure dPEP is {approx}0.21 mJ/m{sup 2} smaller than pure PEP), the GAE method is much less model dependent, ...

1995-12-04

22

Analysis of degradation in nickel-based alloys using focused ion beam imaging and specimen preparation combined with analytical electron microscopy  

International Nuclear Information System (INIS)

Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to thicknesses of only a few tens of ...

2002-09-23

23

A systematic neutron reflectometry study on hydrogen absorption in thin Mg{sub 1-x}Al{sub x} alloy films  

Energy Technology Data Exchange (ETDEWEB)

Various methods for storing hydrogen have been examined in an effort to find ways to store hydrogen in increasingly smaller volumes with decreasing weight of the whole hydrogen storage system. Metal hydrides, in which hydrogen is chemically bound to a metal atom, are considered to be very promising candidates for hydrogen storage because they have high gravimetric and volumetric storage capacities. This study investigated the effect of different magnesium (Mg) and aluminium (Al) ratios on the absorption and desorption properties of thin films. Neutron reflectometry (NR) was used in this study to better understand the absorption and desorption properties of commercially promising hydrogen storage materials. The large negative scattering length of hydrogen atoms changes the reflectivity curve substantially, so that NR can determine the total amount of stored hydrogen as well as the hydrogen distribution along the film normal, with nanometer ...

2010-10-15

24

#omega#-Assisted nucleation and growth of #alpha# precipitates in the Ti-5Al-5Mo-5V-3Cr-0.5Fe #beta# titanium alloy  

International Nuclear Information System (INIS)

This paper discusses the structural and compositional changes at the nanometer scale associated with the nucleation and growth of #alpha# precipitates in the #beta# titanium alloy Ti-5553 (Ti-5Al-5Mo-5 V-3Cr-0.5Fe) with #omega# precipitates acting as heterogeneous nucleation sites. The microstructural evolution in this alloy, during #beta#-solutionizing, quenching and aging type heat-treatments, has been investigated by combining results from scanning electron microscopy, orientation imaging microscopy, transmission electron microscopy, high-resolution TEM and three-dimensional atom probe (3DAP) tomography. Athermal #omega# precipitates form in this alloy on quenching from above the #beta# transus temperature. On isothermal annealing at low temperatures, these #omega# precipitates coarsen to form chemically ordered #omega# precipitates, accompanied by the nucleation of the stable #alpha# phase. Annealing at higher temperatures leads to ...

2009-04-01

25

Fitting the fully coupled ORM for the Fermilab Booster  

Energy Technology Data Exchange (ETDEWEB)

The orbit response matrix (ORM) method [1] is applied to model the Fermilab Booster with parameters such as the BPM gains and rolls, and parameters in the lattice model, including the gradient errors and magnets rolls. We found that the gradients and rolls of the adjacent combined-function magnets were deeply correlated, preventing full determination of the model parameters. Suitable constraints of the parameters were introduced to guarantee an unique, equivalent solution. Simulations show that such solution preserves proper combinations of the adjacent parameters. The result shows that the gradient errors of combined-function magnets are within design limits.

2005-05-01

26

Mechanism of filler action in reducing the wear of PTFE polymer by differential scanning calorimetry  

British Library Electronic Table of Contents (United Kingdom)

Two types of representative nanometer materials, i.e., fibroid nanometer attapulgite and approximate spherical ultrafine diamond, were selected as fillers of polytetrafluoroethylene (PTFE) to study the mechanism of the wear-reducing actions of the fillers in PTFE composites. The friction and wear tests were performed on a block-on-ring wear tester under dry sliding conditions. Differential scanning calorimetry (DSC) was used to investigate material microstructure and to examine modes of failure. No significant change in coefficient of friction was found, but the wear rate of PTFE composites was orders of magnitude less than that of pure PTFE. DSC analysis revealed that nanometer attapulgite and ultrafine diamond played a heterogeneous nucleation role in PTFE matrix and consequently resulte...

2007-01-01

27

Spectroscopic ellipsometry and polarimetry for materials and systems analysis at the nanometer scale: state-of-the-art, potential, and perspectives  

UK PubMed Central (United Kingdom)

This paper discusses the fundamentals, applications, potential, limitations, and future perspectives of polarized light reflection techniques for the characterization of materials and related systems...Full Text Available

2009-10-01

28

Phytochrome-induced Increase of Fluorescein Translocation in Mung Bean Hypocotyls  

UK PubMed Central (United Kingdom)

Moderate doses of red (660 nanometer) irradiation cause a rapid increase in the translocation of fluorescein in dark-grown mung bean hypocotyl (Vigna radiata L.) segments. The increase...Full Text Available

1978-07-01

29

Photosynthetic Response of Seagrasses to Ultraviolet-A Radiation and the Influence of Visible Light Intensity 1  

UK PubMed Central (United Kingdom)

Inhibition of photosynthesis by ultraviolet-A radiation (UV-A, 315-380 nanometers) was examined in three marine angiosperms: Halophila engelmannii Aschers, Halodule wrightii...Full Text Available

1982-02-01

30

Land Cover Classification Comparison with Different Resolution ...  

Science.gov (United States)

Dec 9, 2005 ... Classification of high resolution imagery is not as straightforward as more ... The challenges of classifying high resolution imagery stems ...

31

A Trajectory Correction based on Multi-Step Lining-up for the CLIC Main Linac  

CERN Document Server

In the CLIC main linac it is very important to minimise the trajectory excursion and consequently the emittance dilution in order to obtain the required luminosity. Several algorithms have been proposed and lately the ballistic method has proved to be very effective. The trajectory method described in this Note retains the main advantages of the latter while adding some interesting features. It is based on the separation of the unknown variables like the quadrupole misalignments, the offset and slope of the injection straight line and the misalignments of the beam position monitors (BPM). This is achieved by referring the trajectory relatively to the injection line and not to the average pre-alignment line and by using two trajectories each corresponding to slightly different quadrupole strengths. A reference straight line is then derived onto which the beam is bent by a kick obtained by moving the first quadrupole. The other quadrupoles are then aligned on that ...

1999-01-01

32

Manganese oxide nanowires, films, and membranes and methods of making  

Energy Technology Data Exchange (ETDEWEB)

Nanowires, films, and membranes comprising ordered porous manganese oxide-based octahedral molecular sieves, and methods of making, are disclosed. A single crystal ultra-long nanowire includes an ordered porous manganese oxide-based octahedral molecular sieve, and has an average length greater than about 10 micrometers and an average diameter of about 5 nanometers to about 100 nanometers. A film comprises a microporous network comprising a plurality of single crystal nanowires in the form of a layer, wherein a plurality of layers is stacked on a surface of a substrate, wherein the nanowires of each layer are substantially axially aligned. A free standing membrane comprises a microporous network comprising a plurality of single crystal nanowires in the form of a layer, wherein a plurality of layers is aggregately stacked, and wherein the nanowires of each layer are substantially axially aligned.

2008-10-21

33

Presentation of twentieth century atmospheric carbon dioxide record in Smithsonian spectrographic plates  

Energy Technology Data Exchange (ETDEWEB)

The observed strength of the carbon dioxide absorption bands recorded on spectrobolograms of the transparency of the earth's atmosphere between wavelengths 300 and 2500 nanometers as part of the Smithsonian Solar Constant Program were used to extract the abundance of carbon dioxide in the atmosphere. The details of the analysis and the sources of error are discussed. 11 references, 5 figures, 1 table. (ACR)

1983-11-01

34

Nuclear Raman processes and the development of gamma-ray lasers  

International Nuclear Information System (INIS)

This review briefly describes current efforts to develop superradiant sources of coherent radiation for the sub-nanometer range of wavelenghs, using nuclear rather than the atomic or molecular transitions that are stimulated in existing lasers. First the radiative (including Raman) interactions of nuclei with those of atoms and molecules are compared; then the present status of research on the fundamental problems involved in stimulating nuclear gamma radiation is described. (author). 20 refs.; 2 figs.

35

Nanocrystalline materials: Interfaces and mesoscopic correlations studied by neutron scattering  

International Nuclear Information System (INIS)

Nanocrystalline materials can exhibit properties which are considerably different from their coarse-grained counterparts, making them unique for basic or applied research and also very promising for potential applications. The topics which are addressed in the present paper are magnetic properties and magnetic correlations on the nanometer scale, mechanical properties, in particular the influence of grain boundaries on the elastic and plastic behaviour, and vibration models of grain boundary atoms in nanostructured materials. (author)

2001-09-23

36

Fibre coupled dual-mode waveguide interferometer with $\\lambda $/130 fringe spacing  

CERN Document Server

Predictions and measurements of a multimode waveguide interferometer operating in a fibre coupled, ``dual-mode'' regime are reported. With a 1.32 micrometer source, a complete switching cycle of the output beam is produced by a 10.0 nanometer incremental change in the 8.0 micrometer width of the hollow planar mirror waveguide. This equates to a fringe spacing of $\\sim\\lambda /130$. This is an order of magnitude smaller than previously reported results for this form of interferometer.

2008-01-01

37

The effect of swimming exercise on spontaneous ventricular defibrillation and ventricular fibrillation threshold in the isolated perfused rat heart.  

Science.gov (United States)

Effects of swimming exercise training on left ventricular contraction and relaxation, the incidence of spontaneous defibrillation and the ventricular fibrillation threshold were studied in the isolated, perfused rat heart. The heart/body weight ratio was 4.8 +/- 0.4 x 10(-3) in swimmers compared with 3.9 +/- 0.6 x 10(-3) in sedentary controls (p less than 0.0005). The spontaneous heart rate was lower in isolated hearts of trained animals (222 +/- 18 bpm compared with 244 +/- 28, p less than 0.05). Left ventricular systolic pressure was higher in trained hearts and the rate of ventricular relaxation enhanced (p less than 0.05). The ventricular fibrillation threshold was 7.2 +/- 5.2 and 10.8 +/- 6.1 mamp in hearts of swimmers and controls, respectively, the difference not being significant. The incidence of spontaneous defibrillation was not significantly different between the two groups. It is concluded that, while swimming induces cardiac hypertrophy and ...

1990-12-01

38

TTF HOM Data Analysis with Curve Fitting Method  

Energy Technology Data Exchange (ETDEWEB)

To investigate the possibility of using HOM signals induced in SC cavities as beam and cavity diagnostics, narrow band (20 MHz) data was recorded around the strong TE111-6(6{pi}/9-like) dipole modes (1.7 GHz) in the 40 L-band (1.3 GHz) cavities at the DESY TTF facility. The analyses of these data have so far focused on using a Singular Value Decomposition (SVD) technique to correlate the signals with each other and data from conventional BPMs to show the dipole signals provide an alternate means of measuring the beam trajectory. However, these analyses do not extract the modal information (i.e., frequencies and Q's of the nearly degenerate horizontal and vertical modes). In this paper, we described a method to fit the signal frequency spectrum to obtain this information, and then use the resulting mode amplitudes and phases together with conventional BPM data to determine the mode polarizations and relative centers and tilts. Compared with the SVD ...

2009-07-14

39

Mechanical Engineering and Design of the LHC Phase II Collimators  

CERN Document Server

Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time and improve beam monitoring. An adjustment ...

2010-01-01

40

Report of the Geostatistical Analysis of High Resolution ...  

Science.gov (United States)

... The variogram analysis of the high resolution imagery has shown that although more spatial scales have been identified than from the SPOT image ...

1998-05-01

41

Synthesis, microstructure and photoluminescence of Eu{sup 3+}/Tb{sup 3+} activated Y{sub 2}SiO{sub 5} nanophosphors by new silicate sources  

Energy Technology Data Exchange (ETDEWEB)

Y{sub 2-x}Tb{sub x}SiO{sub 5} and Y{sub 2-x}Eu{sub x}SiO{sub 5} nanophosphors with seven different kinds of silicate sources were synthesized by sol-gel method. The structures have been investigated to be composed of nanometer-size grains of 30-60 nm through X-ray diffraction (XRD) and scanning electron microscopy (SEM) was used to compare the different morphology of patterns from seven different silicon sources. The photoluminescence of Y{sub 2-x}Tb{sub x}SiO{sub 5} was investigated as a function of silicate sources and the results revealed that these nanometer materials showed the characteristic emission {sup 5}D{sub 4} {yields} {sup 7}F{sub J} (J 6, 5, 4, 3) of Tb ions. The characteristic emission {sup 5}D{sub 0} {yields} {sup 7}F{sub J} (J = 1, 2, 4) of Eu ions was also found in the materials of Y{sub 2-x}Eu{sub x}SiO{sub 5}.

2008-01-15

42

Focused ion beam etching of nanometer-size GaN/AlGaN device structures and their optical characterization by micro-photoluminescence/Raman mapping  

Energy Technology Data Exchange (ETDEWEB)

The authors report on the nano-fabrication of GaN/AlGaN device structures using focused ion beam (FIB) etching, illustrated on a GaN/AlGaN heterostructure field effect transistor (HFET). Pillars as small as 20nm to 300nm in diameter were fabricated from the GaN/AlGaN HFET. Micro-photoluminescence and UV micro-Raman maps were recorded from the FIB-etched pattern to assess its material quality. Photoluminescence was detected from 300nm-size GaN/AlGaN HFET pillars, i.e., from the AlGaN as well as the GaN layers in the device structure, despite the induced etch damage. Properties of the GaN and the AlGaN layers in the FIB-etched areas were mapped using UV Micro-Raman spectroscopy. Damage introduced by FIB-etching was assessed. The fabricated nanometer-size GaN/AlGaN structures were found to be of good quality. The results demonstrate the potential of FIB-etching for the nano-fabrication of III-V nitride devices.

2000-07-01

43

Direct sub-nanometer scale electron microscopy analysis of anion incorporation to self-ordered anodic alumina layers  

International Nuclear Information System (INIS)

Research highlights: #-># Morphological and chemical characterization at atomic scale of porous alumina layers anodised in ordered regimes. #-># Characterization based on the use of FEG-SEM, STEM-HAADF, STEM-EELS and STEM-X-EDS. #-># Nanoscale distribution of P-, C- and S-bearing species in the pore wall. - Abstract: Ordered porous alumina layers prepared by two-step anodising in phosphoric, oxalic and sulphuric acids have been characterized at sub-nanometer scale using electron microscopy techniques. FEG-SEM and STEM-HAADF images allowed estimating the pore size, cell wall and pore wall thicknesses of the layers. Nanoanalytical characterization has been performed by STEM-EELS and STEM-X-EDS. Detailed features of the spatial distribution of anions in the pore wall of the films have been obtained. Maximum concentration of P-species occurs, approximately, at the middle of the pore wall; adjacent to the pore for C-species, whereas the distribution of ...

2010-11-01

44

Depth profile analysis on the nanometer scale by a combination of electron probe microanalysis (EPMA) and focused ion beam specimen preparation (FIB)  

International Nuclear Information System (INIS)

Electron probe microanalysis (EPMA) offers high sensitivity and high accuracy in quantitative measurements of chemical compositions and mass coverages. Owing to the low detection limits of the wavelength-dispersive technique, monolayers with mass coverages of about 0.05 pg cm z can be detected. Assuming a density of 5 g cm--3 this corresponds to a thickness of 0.1 nm. With these advantages in mind, EPMA was extended to depth profile analysis in the sub-micron range using a surface removal technique. The present paper shows how depth profile analysis can be improved by combining EPMA and the focused ion beam (FIB) technique. The focused ion beam system uses a Ga+ ion beam. The ion beam allows the milling of defined geometries on the nanometer scale, so that very shallow bevels with exactly defined angles in relation to the surface can be obtained. Low surface damage is expected due to low sputtering effects. Calibrated WDX measurements along the bevel deliver ...

45

Ten-nanometer surface intrusions in room temperature silicon  

CERN Document Server

Defects ~10 nm in size, with number densities ~10^{10} cm^{-2}, form spontaneously beneath ion-milled, etched, or HF-dipped silicon surfaces examined in our Ti-ion getter-pumped transmission electron microscope (TEM) after exposure to air. They appear as weakly-strained non-crystalline intrusions into silicon bulk, that show up best in the TEM under conditions of strong edge or bend contrast. If ambient air exposure is <10 minutes, defect nucleation and growth can be monitored {\\em in situ}. Possible mechanisms of formation are discussed.

2002-01-01

46

Stresses and interfacial structure in Au-Ni and Ag-Cu metallic multilayers  

Energy Technology Data Exchange (ETDEWEB)

Metallic multilayers offer a fantastic playground to investigate elastic stresses in films of nanometer thickness. We will present and discuss a few examples from our recent work on Au-Ni and Ag-Cu systems where we combined plate bending measurements and electron or X-ray diffraction to investigate stress buildup and interfacial mixing. Comparing these two cases we discuss the results with respect to basic parameters like the misfits in lattice parameters and in elastic moduli, the mixing enthalpies and the surface energies.

2004-03-15

47

In-situ TEM study of dislocation-twin boundaries interaction in nanotwinned Cu films  

British Library Electronic Table of Contents (United Kingdom)

Epitaxial thin films of nanotwinned face-centered cubic metals such as Cu possess an unprecedented combination of high hardness and high electrical conductivity due to the unique structure of nanometer-spaced coherent twin boundaries. Recent studies of in-situ nanoindentation in a transmission electron microscope have provided new insights on the deformation behavior of nanotwins that are reviewed here. In particular, two unit processes are highlighted: first, stress-induced migration of ?3 {112} incoherent twin boundary that leads to de-twinning of nanotwins; second, twinning dislocation can be multiplied at ?3 {111} coherent twin boundary.

2011-01-01

48

Final report for Grant No. DOE/DE-FG02-98ER14909: Experimental and modeling studies of nanometer aerosol filtration  

Energy Technology Data Exchange (ETDEWEB)

The primary objective is to perform a fundamental study of filtration of nanoparticles, and to obtain filtration knowledge necessary to design particle collection devices/systems for nanoparticle processing and for preventing nanoparticle emissions into the environment. The research covered a wide area relevant to nanoparticle filtration, under these main topics: (1) nanoparticle filtration and molecular dynamics simulation, (2) nanoparticle virtual impactor, (3) particle transport under low pressure, and (4) development of a high-throughput nanoparticle generator. A number of novel tools and numerical models have been developed under the DOE support.

2002-12-10

49

Fabrication of 10nm diameter carbon nanopores  

Energy Technology Data Exchange (ETDEWEB)

The addition of carbon to samples, during imaging, presents a barrier to accurate TEM analysis, the controlled deposition of hydrocarbons by a focused electron beam can be a useful technique for local nanometer-scale sculpting of material. Here we use hydrocarbon deposition to form nanopores from larger focused ion beam (FIB) holes in silicon nitride membranes. Using this method, we close 100-200nm diameter holes to diameters of 10nm and below, with deposition rates of 0.6nm per minute. I-V characteristics of electrolytic flow through these nanopores agree quantitatively with a one dimensional model at all examined salt concentrations.

2008-09-25

50

Development of conductive nanotemplates on ZnSe  

International Nuclear Information System (INIS)

We demonstrate the possibility to fabricate arrays of pores oriented perpendicular and parallel to the top surface of the ZnSe nanotemplate. The control of material conductivity allows one to produce porous ZnSe samples with the mean pore diameter and characteristic skeleton wall thickness from several hundreds of nanometers to about 15 nm. In addition, electrochemical treatment of ZnSe single crystals using photoresist masks allows one to prepare buried porous structures with pores directed parallel to the top template surface, which is especially important for photonic applications.

2011-07-07

57

Scale-dependent errors in the estimation of land-cover proportions. Implications for global land-cover datasets  

Energy Technology Data Exchange (ETDEWEB)

Aggregation of fine-resolution land-cover maps to coarser scales indicates that estimates of the proportions of land-cover types vary as a function of spatial resolution. The magnitude of these proportional errors in a forested area in northern California increase significantly as resolution exceeds a 90-m threshold. These errors could pose difficulties for the use of land-cover products generated from coarse-resolution sensors such as the NOAA-AVHRR and the MODIS sensor planned for the EOS program. The magnitude of the errors appears to be a function of the spatial resolution of the map, the original size of the land-cover classes, and the spatial patterns of the classes.

1994-05-01

58

Improvement of spatial resolution in the longitudinal direction for isotropic imaging in helical CT  

Energy Technology Data Exchange (ETDEWEB)

Experiments were conducted to confirm the isotropic spatial resolution of multislice CT with a 0.5 mm slice thickness. Isotropic spatial resolution means that the spatial resolution in the transaxial plane (X-Y plane) and that in the longitudinal direction (Z direction) are equivalent. To obtain point spread function (PSF) values in the X-Y-Z directions, three-dimensional voxel data were obtained by helical scanning of a bead phantom. The modulation transfer function (MTF) values were then obtained by three-dimensional Fourier transform of the PSF. Evaluation of the spatial resolution in the X-Y-Z directions by the MTF values showed that the spatial resolution in the Z direction does not depend on the reconstruction kernel used. It was also found that the spatial resolution in the Z direction, as compared with that in the X-Y plane, is superior with the standard ...

2007-02-07

59

Visual mental imagery during caloric vestibular stimulation  

UK PubMed Central (United Kingdom)

We investigated high-resolution mental imagery and mental rotation, while the participants received caloric vestibular stimulation. High-resolution visual mental imagery tasks have been shown...Full Text Available

2006-01-01

60

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system ...

2001-01-01

61

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

62

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

63

Investigation of the hadronic final state in electron-proton interactions at HERA  

Energy Technology Data Exchange (ETDEWEB)

The main subject of this thesis is the study of the hardronic final state in deep-inelastic electron-proton scattering. Theexperiment described in this thesis is performed with such a high resolution that the substructure of the proton is probed by the electron beam with a resolution of less than 10{sup -15} cm. (orig./HSI).

1995-09-18

64

High-resolution infrared observations in IC 5146  

Energy Technology Data Exchange (ETDEWEB)

High-resolution near-infrared and far-infrared observations are presented of the southeastern molecular cloud fragment in the IC 5146 dark cloud. These observations rule out earlier suggestions for the formation of massive stars in this fragment.

1984-04-01

65

High-Speed Ultrahigh-Resolution Optical Coherence Tomography Findings in Chronic Solar Retinopathy  

UK PubMed Central (United Kingdom)

PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available

2008-01-01

66

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

67

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

68

Changes in Gingival Crevicular Fluid Inflammatory Mediator Levels during the Induction and Resolution of Experimental Gingivitis in Humans  

UK PubMed Central (United Kingdom)

AimThe goal of this study is to characterize the changes in 33 biomarkers within the gingival crevicular fluid during the 3-week induction and 4-week resolution of...Full Text Available

2010-04-01

69

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

70

SAMS Research and Development  

Science.gov (United States)

... resolution video. RESULTS Statistics describing the typical inertial navigation error growth were collected. Typical errors ...

2008-08-06

72

Nuclear structure physics at high resolution  

Energy Technology Data Exchange (ETDEWEB)

Techniques for studying nuclear structure are reviewed. Examples are given of charge density determinations by electron and proton inelastic scattering. (AIP)

1985-04-01

73

High Resolution Mesoscale Weather Data Improvement to ...  

Science.gov (United States)

... that defines hydrometeor categories for the duration of the simulation ... and to observe the movement of any particular system ... particle settling occurred ...

2007-03-01

74
75

Detection and Diagnosis of Oral Neoplasia with an Optical ...  

Science.gov (United States)

... Thus, 0CM provides the potential to image epithelial tissue with the subcellular resolution needed to assess the pathologic state of tissue. ...

76

C-CAP Land Cover, Maui, Hawaii 2006  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

77

Alignment accuracy of focused ion beam implantation  

Energy Technology Data Exchange (ETDEWEB)

The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.

1987-06-01

79

UV-induced switching behavior of novel fluoroalkyl end-capped vinyltrimethoxysilane oligomer/titanium oxide nanocomposite between superhydrophobicity and superhydrophilicity with good oleophobicity  

British Library Electronic Table of Contents (United Kingdom)

Fluoroalkyl end-capped vinyltrimethoxysilane oligomer suffered the sol-gel reaction under alkaline conditions in the presence of titanium oxide nanoparticles in tetrahydrofuran to afford the corresponding fluorinated oligomer/titanium oxide nanocomposites[RF-(VM-SiO2)n-RF/TiO2] in excellent to moderate isolated yields. These fluorinated composites thus obtained were nanometer size-controlled fine particles, and exhibited good dispersibility and stability in traditional organic solvents except for water. These fluorinated nanocomposites were applied to the surface modification of glass to exhibit not only a completely superhydrophobic characteristic (a water contact angle: 180degree) with a non-wetting property against water droplets but also a good oleophobicity imparted by fluoroalkyl seg...

2010-01-01

80

Three-terminal electric transport measurements on gold nano-particles combined with ex situ TEM inspection  

International Nuclear Information System (INIS)

We have fabricated nanometer-spaced electrodes on electron-transparent silicon nitride membranes. A thin Cr/Au layer is evaporated on the backside of the membrane which serves as a gate electrode. Using these devices, we have performed three-terminal electron transport measurements on gold nano-particles at liquid helium temperature. Coulomb Blockade features have been observed and the capacitance to the gate has been extracted. After transport measurements, the Cr/Au back gate is removed and the devices are inspected with a transmission-electron microscope (TEM). TEM inspection reveals the presence of a few nano-particles in the nanogap, which is in agreement with the transport measurements. In addition, the nano-particle size as observed by TEM coincides with the one estimated from the gate capacitance value.

2009-10-14

81

Surface modification and characterization for dispersion stability of inorganic nanometer-scaled particles in liquid media  

International Nuclear Information System (INIS)

Inorganic nanoparticles are indispensable for science and technology as materials, pigments and cosmetics products. Improving the dispersion stability of nanoparticles in various liquids is essential for those applications. In this review, we discuss why it is difficult to control the stability of nanoparticles in liquids. We also overview the role of surface interaction between nanoparticles in their dispersion and characterization, e.g. by colloid probe atomic force microscopy (CP-AFM). Two types of surface modification concepts, post-synthesis and in situ modification, were investigated in many previous studies. Here, we focus on post-synthesis modification using adsorption of various kinds of polymer dispersants and surfactants on the particle surface, as well as surface chemical reactions of silane coupling agents. We discuss CP-AFM as a technique to analyze the surface interaction between nanoparticles and the effect of surface modification on the nanoparticle dispersion in ...

2010-08-01

82

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

83

Preparation and applications of novel fluoroalkyl end-capped vinyltrimethoxysilane oligomer/hydroxyapatite nanocomposites  

British Library Electronic Table of Contents (United Kingdom)

Novel fluoroalkyl end-capped vinyltrimethoxysilane oligomer/hydroxyapatite (HAp) nanocomposites were prepared by the reaction of calcium nitrate tetrahydrate and phosphoric acid in the presence of the corresponding oligomer. These fluorinated oligomer/HAp composites thus obtained are nanometer size-controlled fine particles (83-173 nm), and were found to exhibit good dispersibility in methanol, ethanol, and isopropyl alcohol. These fluorinated HAp nanocomposites were applied to the surface modification of glass and poly(methyl methacrylate) (PMMA) to exhibit good hydro- and oleophobic characteristics imparted by fluorine on their surface. In addition, the surface structural changes of the modified polyethylene terephtalate and PMMA films treated with these fluorinated nanocomposites before...

2009-01-01

84

Observation of dust stream formation produced by low current, high voltage cathode spots  

International Nuclear Information System (INIS)

Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic macroparticles formed during this process.

2004-04-01

85

Microstructure and mechanical behaviour of an elevated temperature Mg-rare earth based alloy  

International Nuclear Information System (INIS)

AM-SC1 is a heat treatable magnesium alloy that has been specifically developed to achieve the elevated temperature strength and creep properties necessary for engine block applications. This paper describes the interrelationship between the microstructure and the mechanical properties of AM-SC1. The compressive and tensile strengths are relatively insensitive to temperature up to and including 450 K and the tensile yield behaviour deviates from a standard Hall-Petch relationship at grain sizes below 200 ?m. The microstructural features contributing to the creep resistance are both inter- and intra-granular in nature and are on length scales from nanometers to micrometers. The creep behaviour at 423 K and 450 K is diffusion controlled, with any contribution from the grain boundaries being negligible.

2009-04-15

86

Linearized augmented-plane-wave method for quasi-unidimensional systems: Carbyne and nanotube (Sc@C{sub 20})  

Energy Technology Data Exchange (ETDEWEB)

The advent of carbon nanotubes, which are graphite layers convoluted in cylinders several nanometers in diameter and several micrometers in length, as well as the experiments on implanting metal atoms in such tubes open the way to producing nanoconductors and other materials with unique properties. For theorists, the basic challenge is interpreting and predicting the structure and properties of these systems. The linearized augmented-plane-wave method (LAPW) is one of the most accurate methods in the theory of the electronic structure of solids. A generalization of this method for quasi-two-dimensional systems, surface electronic states, and layered crystals is known. The LAPW theory for quasi-unidimensional systems, which exhibit translational symmetry in one direction, has been absent thus far. In this paper, the authors suggest a version of such a theory and use this method to calculate the electronic structure of carbyne (a linear chain of carbon atoms) and ...

1995-10-01

87

High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry  

CERN Document Server

In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.

2004-01-01

88

Fifth international scientific conference ?Sviridov?s Readings-2010? (Minsk, Republic of Belarus, April 6?9, 2010)  

British Library Electronic Table of Contents (United Kingdom)

The author analyzes conference materials, emphasizing the studies and latest developments useful for industrial heterogeneous catalysis in view of the requirements of green chemistry. Industrial catalysts is developing along a nanometer scale, so especial attention is devoted to analyzing the reports in the Nanochemistry section on the creation of nanocatalysts, the production of active phase nanoparticles, and the formation of new synthesized material properties. The catalysts developed earlier by Russian research in cooperation with Belarusian scientists are considered, and it is shown that not only are expensive nanocontacts extremely promising for industry, but the efficient and economic low-percentage new generation of nanocatalysts synthesized by wet chemistry and containing nanopart...

2010-01-01

89

Direct patterning of complex oxides by pulsed laser deposition through stencils  

International Nuclear Information System (INIS)

The possibilities to grow isolated structures of complex oxides by pulsed laser deposition through stencils were investigated. A stencil consisting of a SiN membrane with apertures of several hundred nanometers embedded in a Si chip is placed in front of a heated substrate (up to 750 degrees Celsius). Deposition through these apertures results in resistless, direct patterning by local deposition of complex oxides like ferroelectric Lead Zirconate Titanate. The created isolated structures were analyzed by AFM imaging. Under-deposition, in this work called broadening, is inevitable during stencil deposition and is depending on deposition parameters, especially pressure. Different causes of broadening are mapped and discussed.

2007-04-01

90

Crossover of the magnetic levels and adiabatic magnetization of the mesoscopic cluster V15  

British Library Electronic Table of Contents (United Kingdom)

The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...

2006-01-01

91

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

92

Observation of $X(3872)\\to J/\\psi \\gamma$ and search for $X(3872)\\to\\psi'\\gamma$ in B decays  

CERN Document Server

We report a study of $B\\to (J/\\psi \\gamma) K$ and $B\\to (\\psi' \\gamma)K$ decay modes using $772\\times 10^{6}$ $B\\bar{B}$ events collected at the \\Upsilon(4S)$ resonance with the Belle detector at the KEKB energy-asymmetric $e^+ e^-$ collider. We observe $X(3872) \\to J/\\psi \\gamma$ and report the first evidence for $\\chi_{c2} \\to J/\\psi \\gamma$ in $B\\to (X_{c\\bar{c}}\\gamma) K$ decays, while in a search for $X(3872) \\to \\psi' \\gamma$ no significant signal is found. We measure the branching fractions, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) \\mathcal{B}(X(3872) \\to J/\\psi\\gamma)$ $=$ $(1.78^{+0.48}_{-0.44}\\pm 0.12)\\times 10^{-6}$, $\\mathcal{B} (B^{\\pm} \\to\\chi_{c2} K^{\\pm})$$=$ $(1.11^{+0.36}_{-0.34} \\pm 0.09) \\times 10^{-5}$, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) \\mathcal{B}(X(3872) \\to \\psi'\\gamma)$ $<$ $3.45\\times 10^{-6}$ (upper limit at 90% C.L.) and also provide upper limits for other searches.

2011-01-01

93

High resolution sequence stratigraphy in China  

International Nuclear Information System (INIS)

Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)

2008-11-01

94

Making porous membranes by chemical etching of heavy-ion tracks in {beta}-PVDF films  

Energy Technology Data Exchange (ETDEWEB)

Production of porous membranes using heavy ion bombardment and subsequent chemical etching of poly(vinylidene difluoride) (PVDF) films has been reported several years ago. However, porous membranes with pore diameter in the nanometer scale requires a better understanding of the chemical etching mechanism. In this work PVDF foils irradiated with Sn ions (2.85 MeV per nucleon) were exposed to several etching conditions which involved permanganate oxidation in different alkaline environments. The solution of KOH 9 mol L{sup -1} and saturated in KMnO{sub 4} was the best etching reactant for PVDF. Functional groups created in the alkaline and oxidative attack by permanganate were studied by FT-IR and UV-vis spectroscopy. The spectroscopic data reveals that the formation of pores occurs by a two-step mechanism: (i) double bonds as a result of dehydrofluorination induced by alkaline media and (ii) oxidation of these double bonds in permanganate solution. The etching ...

2005-07-01

95

Fundamentals of focused ion beam nanostructural processing: below,at and above the surface  

Energy Technology Data Exchange (ETDEWEB)

This article considers the fundamentals of what happens in asolid when it is impacted with a medium energy gallium ion. The study ofthe ion/sample interaction at the nanometer scale is applicable to mostfocused ion beam (FIB) based work even if the FIB/sample interaction isonly a step in the process, e.g., micromachining or microelectronicdevice processing. Whereas the objective in other articles in this issueis to use the FIB tool to characterize a material or to machine a deviceor transmission electron microscopy (TEM) sample, the goal of the FIB inthis article is to have the FIB/sample interaction itself become theproduct. To that end, the FIB/sample interaction is considered in threecategories according to geometry: below, at, and above the surface.First, the FIB ions can penetrate the top atom layer(s) and interactbelow the surface. Ion implantation and ion damage on flat surfaces havebeen comprehensively examined; however, FIB applications require thefurther ...

2007-03-30

96

Basics of Ion Scattering in Nanoscale Materials  

Science.gov (United States)

Energetic ions interact with materials by collisions with the nuclei and electrons of the atoms that make up the material. In these collisions energy and momentum is transferred from the projectile particle which is a moving atom or ion, to the target particles (atomic nucleus or electron). Each collision leads to a slowing down of the moving projectile and also a deflection of the trajectory which gives rise to the term scattering which is often used synonymously to describe the energy transfer process. In this chapter, we introduce from an experimental viewpoint the underlying theory for interaction of ions for analysis and modification of nanometer scale materials. A more detailed theoretical overview of the topic can be found in the recent monographs by Sigmund. Detailed derivations of the formulae introduced will not be given here but can be found in standard texts that are indicated by references. The treatment here starts by considering an individual ...

2010-01-01

97

On the relationship between stacking process and resolution. 2; Jugo shori to bunkaino ni kansuru kiso kenkyu. 2  

Energy Technology Data Exchange (ETDEWEB)

With respect to concept of resolution in seismic exploration using the reflection method, detailed considerations were given on processes of forming the resolution as a result of arranging observation points at vibration transmitting and receiving points. In the discussion, numerical experiments were carried out, in which the scattering stacking process is applied in a model having one scatterer existing in homogeneous media. The experiments investigated an imaging formation process of the scatterer when arrangement of the vibration transmitting and receiving points were changed from a coarse condition to a dense condition while the number of transmitting and receiving points is being increased. Resolution is created if waveforms having finite frequencies are used as input, and the imaging is performed by utilizing the limited number of vibration receiving and transmitting points. If the concept of equi-travel plane is used ...

1997-05-27

98

Study on high-resolution sequence stratigraphy framework of uranium-hosting rock series in Qianjiadian sag  

International Nuclear Information System (INIS)

The ore-hosting Yaojia Formation is composed of a set of braided stream medium-fine grained sediments. Guided by the basic theory of high-resolution sequence stratigraphy, and based on the core observation, the analysis of chemical composition of rocks, and data of natural potential logging and apparent resistivity logging, the authors have set up the high-resolution sequence stratigraphy framework of the ore-hosting Yaojia Formation, and discussed the relation of the stratigraphic structure of the middle cycle, as well as the paleotopography, the micro-facies to the formation of uranium deposit. (authors)

2005-07-01

99

RAPID DAMAGE ASSESSMENT FROM HIGH RESOLUTION IMAGERY  

Energy Technology Data Exchange (ETDEWEB)

Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.

2008-07-01

100

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

101

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

102

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

103

The cross sections of (n, x) nuclear reactions on Pb and Bi at the neutron energy 14.6 MeV  

International Nuclear Information System (INIS)

... compton spectrometers cross sections energy resolution energy-level transitions

2000-06-14

104

Synthesizer Stability Evaluation - NASA Technical Report Server (NTRS)  

Science.gov (United States)

verified via high-resolution spectral density measurements using the Hadamard Variance. .... spectral density measurements were made with the HF5390 ...

105

Simultaneous recognition and segmentation of cells: application in C.elegans  

UK PubMed Central (United Kingdom)

Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available

2011-10-15

106

Self-similarity in NMR Spectra: An Application in Assessing the Level of Cysteine  

UK PubMed Central (United Kingdom)

High resolution of NMR spectroscopic data of biosamples are a rich source of information on the metabolic response to physiological variation or pathological events. There are many advantages...Full Text Available

2010-01-01

107

Science Directed Spacecraft Autonomy for Mars Missions - detail  

Science.gov (United States)

The rapidly growing field of remote sensing is beginning to supply massive amounts of high resolution imagery of the earth and other planets. ...

108

Resolution studies of a GEM-based TPC  

Energy Technology Data Exchange (ETDEWEB)

Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the ...

2006-12-15

109

Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill  

Energy Technology Data Exchange (ETDEWEB)

Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a ...

1997-06-01

110

Postfire soil burn severity mapping with hyperspectral image unmixing  

Science.gov (United States)

Sep 28, 2011... to assess the application of high resolution imagery for burn severity mapping and to compare it to standard burn severity mapping methods. ...

111

PROBING NEAR-SURFACE ATMOSPHERIC TURBULENCE WITH LIDAR MEASUREMENTS AND HIGH-RESOLUTION HYDRODYNAMIC MODELS  

Energy Technology Data Exchange (ETDEWEB)

As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution ...

2000-11-01

113

NASA Satellite Measures Deforestation : Image of the Day  

Science.gov (United States)

Sep 14, 2005 ... For decades, the Brazilian government has been basing estimates of Amazon deforestation on high-resolution Landsat satellite data. Having ...

114

N-Body Code with Adaptive Mesh Refinement  

CERN Document Server

We have developed a simulation code with the techniques which enhance both spatial and time resolution of the PM method for which the spatial resolution is restricted by the spacing of structured mesh. The adaptive mesh refinement (AMR) technique subdivides the cells which satisfy the refinement criterion recursively. The hierarchical meshes are maintained by the special data structure and are modified in accordance with the change of particle distribution. In general, as the resolution of the simulation increases, its time step must be shortened and more computational time is required to complete the simulation. Since the AMR enhances the spatial resolution locally, we reduce the time step locally also, instead of shortening it globally. For this purpose we used a technique of hierarchical time steps (HTS) which changes the time step, from particle to particle, depending on the size of the cell in ...

2001-01-01

116

High resolution (p,p') reactions on "8"7Sr and "8"8Sr  

International Nuclear Information System (INIS)

... levels excited states mev range 10-100 proton reactions proton spectra protons

117

High Resolution Modeling of Coastal Inundation: User ...  

Science.gov (United States)

... Ruth. Preller@nrlssc.navy.mil 76 Marine Technology Society Journal Page 4. ... 78 Marine Technology Society Journal Page 6. ...

2007-07-27

118

Clinical spectrum  

Energy Technology Data Exchange (ETDEWEB)

A tunable diode laser is used to obtain infrared spectra of carbon dioxide in biological materials. The spectral resolution is sufficient to readily distinguish differing isotopic species. The technique may prove useful in clinical tests.

1987-11-01

119

Chronic Disability Syndrome  

UK PubMed Central (United Kingdom)

Prolonged disability is best understood as an illness that exists independently of the initiating disease. The disabled individual goes through predictable stages of disability before resolution occurs....Full Text Available

1991-09-01

120

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Farallon de Pajaros, 2004  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

121

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Anatahan, 2005  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

122

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Aguijan, 2003  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

123

Benefits of Using the Photosimulation Laboratory Environment ...  

Science.gov (United States)

... with the ability to capture imagery in raw 24-bit format, combined with large memory storage devices enable high resolution imagery to be captured ...

2002-08-01

124

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples  

Science.gov (United States)

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to

2003-01-01

125

APOD: April 25, 1996 - In the Center of the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. In the Center of the Whirlpool Credit: N. Panagia (STScI, ESA), NASA Explanation: In the center of M51, a spiral...

2011-10-07

126

APOD: 2011 June 11 - Supernovae in the Whirlpool  

Science.gov (United States)

the picture will download the highest resolution version available. Supernovae in the Whirlpool Image Credit & Copyright: R Jay Gabany Explanation: Where do spiral galaxies keep...

2011-10-07

127

APOD: 2009 May 26 - Whirlpool Galaxy Deep Field  

Science.gov (United States)

Clicking on the picture will download the highest resolution version available. Whirlpool Galaxy Deep Field Credit & Copyright: Jon Christensen Explanation: Follow the handle...

2011-10-07

128

APOD: 2005 November 25 - Moon Over Antarctica  

Science.gov (United States)

on the picture will download the highest resolution version available. Moon Over Antarctica Credit & Copyright: James Behrens (IGPP, Scripps Institution of Oceanography)...

2011-10-14

129

APOD: 2002 July 10 - M51: Cosmic Whirlpool  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: Cosmic Whirlpool Credit & Copyright: Tony and Daphne Hallas Explanation: Follow the handle of the Big...

2011-10-07

130

APOD: 2000 July 24 - M51: The Whirlpool Galaxy  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy Credit & Copyright: Todd Boroson (NOAO), AURA, NOAO, NSF Explanation: The...

2011-10-07

131

A setup for high-resolution isotope shift measurements on unstable lithium isotopes  

Energy Technology Data Exchange (ETDEWEB)

We present a laser spectroscopic approach for measuring the charge radius of the halo nucleus {sup 11}Li and report on recent progress in the development of the experimental apparatus.

2003-05-01

132

49 CFR 240.405 - Processing qualification review petitions.  

Science.gov (United States)

...Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION QUALIFICATION AND CERTIFICATION OF LOCOMOTIVE ENGINEERS Dispute Resolution Procedures § 240.405 Processing qualification review petitions. (a)...

2010-10-01

133

2010 NASA Terrestrial Ecology Science Team Meeting - NASA Carbon ...  

Science.gov (United States)

The biomass maps were compared with the U.S. Forest Service biomass map for 2002 , LVIS height data, and estimates from high resolution imagery. ...

134

2002 C-CAP Land Cover, Territory of American Samoa, Swains  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

135

[Electronic and structural properties of individual nanometer-size supported metallic clusters]. Progress report  

Energy Technology Data Exchange (ETDEWEB)

The research supported by this Department of Energy contract has primarily been devoted to the study of the electronic properties of surfaces with sub-micron size. In previous years, we have studied the photoexcitation of electrons from field emission tips by a focussed Argon-ion laser beam tuned to operate at specific photon energy. The photoexcited electrons escape into the vacuum by tunneling through a surface potential barrier which is distorted by the application of a strong electric field. The interest in these experiments lies in a better understanding of the photoexcitation process at low photon energies. The techniques that have been developed directly measure the excited state energy distribution of electrons emitted through the surface potential barrier. The basic information gained from this research is relevant to opto-electronic devices which rely on photoexcitation of electrons in the presence of strong interfacial electric fields for their operation. In addition, the ...

1991-11-01

136

Ultrathin coatings of nanoporous materials as property enhancements for advanced functional materials  

International Nuclear Information System (INIS)

This report summarizes the findings of a five-month LDRD project funded through Sandia's NTM Investment Area. The project was aimed at providing the foundation for the development of advanced functional materials through the application of ultrathin coatings of microporous or mesoporous materials onto the surface of substrates such as silicon wafers. Prior art teaches that layers of microporous materials such as zeolites may be applied as, e.g., sensor platforms or gas separation membranes. These layers, however, are typically several microns to several hundred microns thick. For many potential applications, vast improvements in the response of a device could be realized if the thickness of the porous layer were reduced to tens of nanometers. However, a basic understanding of how to synthesize or fabricate such ultra-thin layers is lacking. This report describes traditional and novel approaches to the growth of layers of microporous materials on silicon wafers. The ...

137

Structural, optical, electrical and dielectrical properties of electrosynthesized nanocrystalline iron oxide thin films  

International Nuclear Information System (INIS)

Electrodeposition of semiconducting iron oxide (Fe_2O_3) thin film was carried out from an alkaline sulphate bath. A 0.1 M ferrous sulphate (FeSO_4#centre dot#7H_2O) was complexed with 0.1 M citric acid. By addition of 1 N NaOH, pH of the solution was made alkaline (pH=9) and deposition of iron oxide (Fe_2O_3) thin films was carried out potentiostatically at room temperature (300 K). From cyclic voltametry (CV), electrochemical studies were carried out for deposition of iron oxide thin films. The XRD studies reveal that Fe_2O_3 with epsilon (#epsilon#) phase having monoclinic crystal structure is formed. By observing scanning electron microscope (SEM), it is seen that iron oxide films were homogeneous, uniform and well covered to surface of the substrate. Grain size was found to be in nanometers range from XRD analysis. The optical band gap of Fe_2O_3 thin film was estimated to be 1.90 eV. Electrical resistivity was order of 10"4 #OMEGA# cm. Dielectric constant and ...

2003-09-28

138

Selective patterned growth of single-crystal organic nanowires of Ag-TCNQ with chemical raction method  

Energy Technology Data Exchange (ETDEWEB)

Abstract: We report for the selective-area chemical synthesis of semiconductor single-crystal organic nanowires of silver-tetracyanoquinodimethane (Ag-TCNQ). Straight and smooth Ag-TCNQ nanowires can be produced and patterned on micrometer and nanometer scale on silicon substrates covered with a thin layer of Ag film through the reaction of TCNQ and Ag in a simple gas-solid chemical reaction process. Ag-TCNQ nanowires are characterized by UV-vis, IR and Raman spectroscopy, respectively. The Ag-TCNQ nanowires grows preferentially along the [100] direction of strong - stacking of Ag-TCNQ molecules. Nanodevices based on these nanowires are fabricated using focus ion beam (FIB) technique. Electrical properties are characterized and I-V hysteresis is observed, which shows memory effect with electrical switching of three orders on-off ratio. These nanowires could be potential for use in optical storage, ultrahigh-density nanoscale memory and logic devices.

2008-09-01

139

Preparation of Permalloy nanostructures using focused ion beam methods  

International Nuclear Information System (INIS)

Focused ion beam (FIB) milling is a powerful and versatile tool for the maskless fabrication of structures and devices at micro- and nanometer scales. The approach is based on the milling and deposition capabilities of a focused ion beam, where the latter is achieved by ion-beam-assisted decomposition of a metalorganic gas precursor of the specific material that has to be deposited. The combination of FIB and scanning electron microscopy in the same unit (so-called dual-beam unit) further expands the capabilities of the approach by the possibility of performing electron-beam-assisted deposition and inspection. Permalloy nanowires with electrical contacts patterned by FIB-Pt deposition were prepared in the dual-beam unit. Various types of notches to pin magnetic domain walls were additionally fabricated by means of FIB. The fabrication parameters for a structural modification of the Permalloy structures without too strongly affecting the material properties were ...

2010-03-21

140

Preparation and characterization of Co-doped BaTiO{sub 3} nanosized powders and ceramics  

Energy Technology Data Exchange (ETDEWEB)

The Co-doped BaTiO{sub 3} nanosized powders and ceramics were prepared via the sol-gel process. The powders and ceramics were characterized by methods of XRD, SEM and TEM. The dielectric properties of the ceramics were also determined by these methods. The influence of sintering temperature, sintering time and Co concentration on the microstructure and dielectric properties was discussed. The results revealed that the powders were in nanometer scale (30-50 nm) and were mainly composed of cubic BaTiO{sub 3} phase and small amount of BaCO{sub 3}. After sintering, both the cubic BaTiO{sub 3} and BaCO{sub 3} were transformed into tetrahedron BaTiO{sub 3}. The sintering temperatures of the Co-doped BaTiO{sub 3} ceramics decreased (about 100 deg. C) and the Curie temperatures of the ceramics were then moved to lower temperature. In addition, the dielectric constant of the ceramics doping with Co was higher than that of the pure BaTiO{sub 3} ceramics. The dielectric ...

2006-08-25

141

Photocatalytic probing of DNA sequence by using TiO{sub 2}/dopamine-DNA triads.  

Energy Technology Data Exchange (ETDEWEB)

A method to control charge transfer reaction in DNA using hybrid nanometer-sized TiO{sub 2} nanoparticles was developed. In this system extended charge separation reflects the sequence of DNA and was measured using metallic silver deposition or by photocurrent response. Light-induced extended charge separation in these systems was found to be dependent on the DNA-bridge length and sequence. The yield of photocatalytic deposition of silver was studied in systems having GG accepting sites imbedded in AT runs at varying distances from the TiO{sub 2} nanoparticle surface. Weak distance dependence of charge separation indicative of a hole hopping through mediating adenine (A) sites was found. The quantum yield of silver deposition in the system having a GG accepting site placed 8.5 {angstrom} from the nanoparticle surface was found to be {Phi} = 0.70 (70%) and {Phi} = 0.56 (56%) for (A){sub n} and (AT){sub n/2} bridge, respectively. Hole injection to GG trapping sites ...

2007-10-15

142

Optical Pattern Fabrication in Amorphous Silicon Carbide with High-Energy Focused Ion Beams  

International Nuclear Information System (INIS)

Topographic and optical patterns have been fabricated in a-SiC films with a focused high-energy (1 MeV) H"+ and He"+ ion beam and examined with near-field techniques. The patterns have been characterized with atomic force microscopy and scanning near-field optical microscopy to reveal local topography and optical absorption changes as a result of the focused high-energy ion beam induced modification. Apart of a considerable thickness change (thinning tendency), which has been observed in the ion-irradiated areas, the near-field measurements confirm increases of optical absorption in these areas. Although the size of the fabricated optical patterns is in the micron-scale, the present development of the technique allows in principle writing optical patterns up to the nanoscale (several tens of nanometers). The observed values of the optical contrast modulation are sufficient to justify the efficiency of the method for optical data recording using high-energy focused ...

2011-07-01

143

Microstructural and mechanical characterization of high energy ball milled and sintered WC-10wt%Co-xTaC nano powders  

British Library Electronic Table of Contents (United Kingdom)

Ultra fine tungsten carbide and cobalt powders were milled by high energy planetary ball mill at different ball to powder weight ratios (BPR) to produce particles of WC-10wt%Co hard metal in nanometer scale size. Microstructural characterizations by TEM show that the particle size of tungsten carbide was achieved to 32nm after milling at 15 BPR during 10h. In order to reduce the WC grain growth during the sintering process, tantalum carbide was added to the hard metal as a WC grain growth inhibitor. The nano hard metal powders were compacted at 200MPa pressure and sintered at 1370-1450degreeC temperatures in a high purity hydrogen atmosphere. The results show that the addition of 0.6wt% of TaC improves the hardness and fracture toughness from 1493 HV30 and 11.8MPam (for TaC free sample) to...

2009-01-01

144

In-Situ Atr Ftir Probe Investigation of Selective Organic Synthetic Routes Using Nanoscale Crystal Reactors  

Environmental Research Database

ObjectivesThe overall aim of this work is to use an in-situ FTIR probe to investigate selected heterogeneous catalysts in industrially relevant organic reactions. This approach will be broadly applicable to the UK fine chemical manufacturing base.~%~~%~The project has the following specific objectives:~%~~%~- To demonstrate and develop the use of an in-situ FTIR probe in a batch reactor at elevated temperatures (eg greater than 100 deg C) to monitor reactant usage and product formation.~%~~%~- To validat [continued...]DescriptionThis proposal concerns the in-situ study of catalytic processes and reaction kinetics. The catalysts concerned are microporous materials, such as, zeolites, containing pores and cavities of molecular dimensions. These catalysts constitute crystal reactors on a nanometer scale that are selective on a size and shape basis for organic molecules used in this ...

2003-01-31

145

How cells tiptoe on adhesive surfaces before sticking  

CERN Document Server

Cell membranes are studded with protrusions that were thoroughly analyzed with electron microscopy. However, the nanometer-scale three-dimensional motions generated by cell membranes to fit the topography of foreign surfaces and initiate adhesion remain poorly understood. Here, we describe the dynamics of surface deformations displayed by monocytic cells bumping against fibronectin-coated surfaces. We observed membrane undulations with typically 5 nm amplitude and 5-10 second lifetime. Cell membranes behaved as independent units of micrometer size. Cells detected the presence of foreign surfaces at 50 nm separation, resulting in time-dependent amplification of membrane undulations. Molecular contact then ensued with apparent cell-membrane separation of 30-40 nm, and this distance steadily decreased during the following tens of seconds. Contact maturation was associated with in-plane egress of bulky molecules and robust membrane fluctuations. Thus, membrane ...

2008-01-01

146

Fabrication, structure and consolidation of NiAl-Al_2O_3 mechanically alloyed nanocomposite powders  

International Nuclear Information System (INIS)

Reactive milling of NiO + Al powder mixture resulted in the formation of NiAl-Al_2O_3 nanocomposite powders, with a crystallite size of about 20 nm. The Hall-Williamson analysis revealed that NiAl showed an orientation dependent crystallite size after short processing time and orientation dependent internal strain after long milling time. Both anisotropies were removed by heating the powders in the differential scanning calorimetry. Calorimetric studies showed one exothermic effect attributed to the reduction reaction of NiO and endothermic one associated with melting of Al. Two methods were applied for powders compaction: resistance sintering and pulse electric discharge. In both cases the densities of abut 90% of the theoretical value were achieved. A significant increase in average NiAl crystallites size in compacted samples was observed, up to several hundreds of nanometers.(author)

2001-09-23

147

Effects of extreme pressure additive chemistry on rolling element bearing surface durability  

Energy Technology Data Exchange (ETDEWEB)

Lubricant additives have been known to affect rolling element bearing surface durability for many years. Tapered roller bearings were used in fatigue testing of lubricants formulated with gear oil type additive systems. These systems have sulfur- and phosphoruscontaining compounds used for gear protection as well as bearing lubrication. Several variations of a commercially available base additive formulation were tested having modified sulfur components. The variations represent a range of ''active'' extreme pressure (EP) chemistries. The bearing fatigue test results were compared with respect to EP formulation and test conditions. Inner ring near-surface material in selected test bearings was evaluated on two scales: the micrometer scale using optical metallography and the nanometer scale using transmission electron microscopy (TEM). Focused-ion beam (FIB) techniques were used for TEM specimen preparation. Imaging and chemical ...

2007-08-01

148

Effect of boron doping in the carbon support on platinum nanoparticles and carbon corrosion  

Energy Technology Data Exchange (ETDEWEB)

Carbon supported catalysts can lose their activity over a period of time due to the sintering of the nanometer-sized catalyst particles. The sintering of metal clusters on carbon supports can occur due to the weak interaction between the metal and the support and also due to the corrosion of carbon, especially in fuel cell electrocatalysts. The sintering may be reduced by increasing the interaction between the metal and the support and also by increasing the corrosion resistance of carbon supports. In an effort to mitigate the growth of the nanoparticles, carbon-substituted boron defects were introduced in the carbon lattice. The interaction between the Pt nanoparticles on the pure and boron-doped carbon supports was examined using X-ray photoelectron spectroscopy (XPS). The results indicate that the interaction between the Pt nanoparticles and the boron-doped carbon support was slightly stronger than the interaction between the Pt nanoparticles and the pure carbon ...

2009-07-15

149

Characterization of proton exchange membrane materials for fuel cells by solid state nuclear magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel model gives the measured S/V ratios in the normal hydration range of a working fuel ...

2010-03-15

150

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range  

Energy Technology Data Exchange (ETDEWEB)

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron ...

2011-03-14

151

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range  

Energy Technology Data Exchange (ETDEWEB)

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission ...

2010-07-26

152

AFM and STM studies of passive films formed on stainless steels. Applications to stress corrosion cracking; Etudes par microscopie a champ proche des films passifs formes sur les aciers inoxydables. Applications a la corrosion sous contrainte  

Energy Technology Data Exchange (ETDEWEB)

Modelization of crack propagation and theoretical prediction of rupture are the two main objectives of researchers in stress corrosion cracking. Nevertheless, to reach this aim, the behavior of the passive film which appears spontaneously on the substrate in contact with an environment has to be known. This structural and mechanical characterization is all the more difficult because the number of parameters is important: crystallinity rate, defects concentration, thickness (about a few nanometers), electric field, chemical composition (a lot of oxides are present), peeling layers (atomic structure for example) and some hypothesis can be made about their multi-layer structure, their chemical composition or their epitaxial character... Passive films formed on 316L or 304L stainless steels in different aqueous solutions (in ambient air, in MgCl{sub 2} at 117 deg. C...) have been studied and some important remarks about their mechanical properties are made (brittle ...

1995-12-01

153

AFM and STM studies of passive films formed on stainless steels. Applications to stress corrosion cracking  

International Nuclear Information System (INIS)

Modelization of crack propagation and theoretical prediction of rupture are the two main objectives of researchers in stress corrosion cracking. Nevertheless, to reach this aim, the behavior of the passive film which appears spontaneously on the substrate in contact with an environment has to be known. This structural and mechanical characterization is all the more difficult because the number of parameters is important: crystallinity rate, defects concentration, thickness (about a few nanometers), electric field, chemical composition (a lot of oxides are present), peeling layers (atomic structure for example) and some hypothesis can be made about their multi-layer structure, their chemical composition or their epitaxial character... Passive films formed on 316L or 304L stainless steels in different aqueous solutions (in ambient air, in MgCl_2 at 117 deg. C...) have been studied and some important remarks about their mechanical properties are made (brittle ...

1995-06-01

154

A new fuel cell electrocatalyst based on carbonized polyacrylonitrile foam: The nature of platinum-support interactions  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) have been conducted on a new fuel cell electrocatalytic material based on a highly porous carbonized polyacrylonitrile (PAN) microcellular foam with very low platinum loading ({approximately}13 to 23 {micro}g/cm{sup 2}). TEM images of this material clearly show the existence of nanometer size platinum particles which are homogeneously distributed in the highly porous carbonized PAN matrix. An XPS study of Pt-loaded PAN indicates that C 1s, O 1s, and N 1s peaks shift to lower binding energies, compared to virgin PAN. It was concluded that special metal-support interaction exists, through the formation of a charge-transfer complex between platinum and pyridine-type nitrogen atoms of PAN support. This interaction leads to the enhancement of the catalytic activity, and the improvement of the long-time stability of this electrocatalyst.

1997-01-01

155

(Electronic and structural properties of individual nanometer-size supported metallic clusters)  

Energy Technology Data Exchange (ETDEWEB)

The research supported by this Department of Energy contract has primarily been devoted to the study of the electronic properties of surfaces with sub-micron size. In previous years, we have studied the photoexcitation of electrons from field emission tips by a focussed Argon-ion laser beam tuned to operate at specific photon energy. The photoexcited electrons escape into the vacuum by tunneling through a surface potential barrier which is distorted by the application of a strong electric field. The interest in these experiments lies in a better understanding of the photoexcitation process at low photon energies. The techniques that have been developed directly measure the excited state energy distribution of electrons emitted through the surface potential barrier. The basic information gained from this research is relevant to opto-electronic devices which rely on photoexcitation of electrons in the presence of strong interfacial electric fields for their operation. In addition, the ...

1991-11-01

156

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

157

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

158

Metabolomics in Lung Inflammation: A High Resolution 1H NMR Study of Mice Exposed to Silica Dust  

UK PubMed Central (United Kingdom)

Here we report the first 1H NMR metabolomics studies on excised lungs and bronchoalveolar lavage fluid (BALF) from mice exposed to crystalline silica. High resolution 1H...Full Text Available

2008-01-01

159

High-resolution primary ion beam probe for SIMS  

Energy Technology Data Exchange (ETDEWEB)

High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.

2004-06-15

160

High resolution neutron imaging of water in the polymer electrolyte fuel cell membrane  

Energy Technology Data Exchange (ETDEWEB)

Water transport in the ionomeric membrane, typically Nafion{reg_sign}, has profound influence on the performance of the polymer electrolyte fuel cell, in terms of internal resistance and overall water balance. In this work, high resolution neutron imaging of the Nafion{reg_sign} membrane is presented in order to measure water content and through-plane gradients in situ under disparate temperature and humidification conditions.

2009-01-01

161

High resolution imagery of the clumpy irregular galaxy Markarian 325 = NGC 7673  

Energy Technology Data Exchange (ETDEWEB)

High resolution imagery of the clumpy irregular galaxy Mkn 325 shows that some clumps have sizes approximately 300 pc while some may still be unresolved and approximately < 100 pc. In spite of dimensions comparable to - or even smaller than - those of the giant H II complex 30 Doradus, one clump has a star formation rate 100 times higher.

1982-05-01

162

High resolution imagery of the clumpy irregular galaxy Markarian 325 = NGC 7673  

International Nuclear Information System (INIS)

High resolution imagery of the clumpy irregular galaxy Mkn 325 shows that some clumps have sizes approximately 300 pc while some may still be unresolved and approximately < 100 pc. In spite of dimensions comparable to - or even smaller than - those of the giant H II complex 30 Doradus, one clump has a star formation rate 100 times higher. (author).

163

Field-portable lensfree tomographic microscope.  

Science.gov (United States)

We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (?20 mm(3)) on a chip with an axial resolution of Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. PMID:21573311

2011-05-16

164

Ewald sphere correction for single-particle electron microscopy  

Energy Technology Data Exchange (ETDEWEB)

Most algorithms for three-dimensional (3D) reconstruction from electron micrographs assume that images correspond to projections of the 3D structure. This approximation limits the attainable resolution of the reconstruction when the dimensions of the structure exceed the depth of field of the microscope. We have developed two methods to calculate a reconstruction that corrects for the depth of field. Either method applied to synthetic data representing a large virus yields a higher resolution reconstruction than a method lacking this correction.

2006-03-15

165

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

Energy Technology Data Exchange (ETDEWEB)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

1987-03-01

166

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).

1987-01-01

167

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

168

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...

2009-03-07

169

Study of spatial resolution in three-dimensional rotational angiography  

International Nuclear Information System (INIS)

In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased ...

2006-03-01

170

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...

2008-02-01

171

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...

1988-01-01

172

The Development of Meteorological Data Fields for the Radiological Emergency Preparedness  

Energy Technology Data Exchange (ETDEWEB)

In this study we tried to develop the long-range transport system and find the way to prevent from the radiological emergency risk. For the study, meteorological forecast system in Korea Meteorological Administration is investigated. Numerical simulation is also carried out by the long-range transport model and Vis-5D. We surveyed the emergency preparedness for nuclear accidents which were ARAC in USA, RODOS in Europe and WSPEED in Japan and then investigated the processing of medium- and long-range atmospheric diffusion modeling system. We also studied on the application of KMA/NWPD model which are GDAPS and RDAPS. In the future, it is necessary to produce to the high resolution meteorological data from KMA/NWPD for the development of medium- and long-range atmospheric diffusion modeling system and construct the integrated system for data processing in real time. It was simulated by using micro-scale meteorological field applying wind field model with high ...

2000-04-01

173

Very high resolution measurements of the total cross section of natural iron  

Energy Technology Data Exchange (ETDEWEB)

The total cross section of natural Fe has been measured with the GELINA pulsed white neutron source with a time-of-flight resolution of about 3.8 ps/m and good statistical precision. Measurements have been performed on three sample thicknesses including one with an average transmission of 0.1, in order to check for consistency and for remaining resolution effects. The cross sections in the {open_quotes}unresolved resonance region{close_quotes} still show rather strong fluctuations. These data will directly be used in shielding benchmark calculations. The resonance region data will be analysed by an R-matrix routine and the parameters be compared to existing compilations.

1994-12-31

174

The potential of multidiurnal MODIS thermal band data for coal fire detection  

British Library Electronic Table of Contents (United Kingdom)

In this paper we present the results of our analyses of multidiurnal low-resolution Moderate Resolution Imaging Spectroradiometer (MODIS) thermal data for coal fire-related thermal anomaly detection. Results are presented for data of the Jharia coal mining region of India. We combine three relatively new approaches: first, we use low-resolution MODIS data for coal fire area analyses, which has only been undertaken by a few authors. Second, we analyse data from four different times of day (morning, afternoon, evening and predawn) and for three different bands (MODIS bands 20, 32 and a ratio thereof); and third, we use an unbiased automated algorithm for thermal anomaly extraction of local thermal anomalies. The MODIS data analysed stem from the years 2001 and 2005. In 2001, MODIS data were ...

2008-01-01

175

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

176

Quadrant anode image sensor  

Science.gov (United States)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)

1976-11-01

177

Quadrant anode image sensor  

International Nuclear Information System (INIS)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.

9472-01-01

178

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...

2006-10-29

179

NEXAFS microscopy of polymeric materials: Successes and challenges encountered when characterizing organic devices  

Energy Technology Data Exchange (ETDEWEB)

We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.

2009-09-01

180

Isomorphisms of quantizations via quantization of resolutions  

CERN Document Server

In this paper we prove the existence of isomorphisms between certain non-commutative algebras that are interesting from representation theoretic perspective and arise as quantizations of certain Poisson algebras. We show that quantizations of Kleinian resolutions obtained by three different constructions are isomorphic to each other. The constructions are via symplectic reflection algebras, quantum Hamiltonian reduction, and W-algebras. Next, we prove that parabolic W-algebras in type A are isomorphic to quantum Hamiltonian reductions associated to quivers of type A. Finally, we show that the symplectic reflection algebras for wreath-products of the symmetric group and a Kleinian group are isomorphic to certain quantum Hamiltonian reductions. Our results involving W-algebras are new, while for those dealing with symplectic reflection algebras we just give new proofs. A key ingredient in our proofs is the study of quantizations of symplectic ...

2010-01-01

181

High-resolution sequence stratigraphy and its controls on uranium mineralization. Taking middle Jurassic Qingtujing formation in Chaoshui basin as an example  

International Nuclear Information System (INIS)

By applying the high-resolution sequence stratigraphy, the different sub-divisions of base-level cycles of Qingtujing Formation, Middle Jurassic in Chaoshui Basin are analyzed in detail. 23 short, 3 middle and 1 long base-level cycles are recognized. On the above basis, the corresponding frameworks of high-resolution sequence stratigraphy have been established in northern and southern sub-basins respectively, and the detailed sedimentary facies of MSC_1_-_3 and the special distribution of Qintujing Formation are discussed. It is pointed out that MSC_2 is the most favorable layer for the localization of sandstone-type uranium deposits. (authors)

2006-06-01

182

High-resolution NMR on /sup 29/Si nuclei in acidic zeolites  

Science.gov (United States)

The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.

1986-12-01

183

High speed inverted optical-resolution photoacoustic microscopy  

Science.gov (United States)

Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.

2011-02-01

184

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

185

Automatic Extraction of Open Space Area from High Resolution Urban Satellite Imagery  

CERN Document Server

In the 21st century, Aerial and satellite images are information rich. They are also complex to analyze. For GIS systems, many features require fast and reliable extraction of open space area from high resolution satellite imagery. In this paper we will study efficient and reliable automatic extraction algorithm to find out the open space area from the high resolution urban satellite imagery. This automatic extraction algorithm uses some filters and segmentations and grouping is applying on satellite images. And the result images may use to calculate the total available open space area and the built up area. It may also use to compare the difference between present and past open space area using historical urban satellite images of that same projection

2011-01-01

186

Analysis of Ground Deformation Detected Using the SBAS-DInSAR Technique in Umbria, Central Italy  

British Library Electronic Table of Contents (United Kingdom)

Ground deformation affecting the Umbria region (central Italy) in the 9-year period from 1992 to 2000 was investigated through multi-temporal Differential Synthetic Aperture Radar Interferometry (DInSAR). For the purpose, the Small BAseline Subset (SBAS) technique was adopted, which allows studying the temporal evolution of the detected deformation at two spatial scales: a low-resolution (regional) scale, and a full-resolution (local) scale. For the analysis, SAR data acquired by the European Remote Sensing (ERS-1/2) satellites along ascending and descending orbits were used. The detected deformation was analysed to investigate its relevance to geophysical, geomorphologic, and human-induced processes that may result in hazardous conditions to the population of Umbria. Low-resolution deform...

2009-01-01

187

X-ray structure of sensory rhodopsin II at 2.1-? resolution  

UK PubMed Central (United Kingdom)

Sensory rhodopsins (SRs) belong to a subfamily of heptahelical transmembrane proteins containing a retinal chromophore. These photoreceptors mediate the cascade of vision in animal eyes and phototaxis...Full Text Available

2001-08-28

188

Teaching electron diffraction and imaging of macromolecules.  

UK PubMed Central (United Kingdom)

Electron microscopic analysis can be used to determine the three-dimensional structures of macromolecules at resolutions ranging between 3 and 30 A. It differs from nuclear magnetic resonance spectroscopy...Full Text Available

1993-05-01

189

Tandem repeats analysis for the high resolution phylogenetic analysis of Yersinia pestis  

UK PubMed Central (United Kingdom)

BackgroundYersinia pestis, the agent of plague, is a young and highly monomorphic species. Three biovars, each one thought to be associated with the last three Y....Full Text Available

190

THE OGIP FORMAT FOR 2-D (IMAGE) POINT SPREAD FUNCTION ... - NASA  

Science.gov (United States)

tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...

191

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

192

Solid-state 13C NMR spectroscopy of a 13C carbonyl-labeled polypeptide  

UK PubMed Central (United Kingdom)

High resolution structural elucidation of macromolecular structure by solid-state nuclear magnetic resonance requires the preparation of uniformly aligned samples that are isotopically labeled. In...Full Text Available

1992-06-01

193

Sensitivity of psychophysical measures to signal processor modifications in cochlear implant users  

UK PubMed Central (United Kingdom)

Experienced users of the Clarion cochlear implant were tested acutely with the HiResolution (HiRes) and HiRes Fidelity120 (F120) processing strategies. Three psychophysically-based tests were...Full Text Available

2010-04-01

194

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

195

SCALER WITH RESOLUTION TIME EQUAL TO 10 NANOSECONDS  

Science.gov (United States)

In systems of fast decimal counters, there are three problems to be resolved: to study a bistable having a short switching time, to form with the aid of three bistables a circuit divisible by 5, and to normalize the input pulses. The solutions to these problems for the nonsecond scaler are presented. (J.S.R.)

1960-01-01

196

Research in heavy-ion nuclear physics  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.

1992-01-01

197

Photophysics and optical switching in green fluorescent protein mutants  

UK PubMed Central (United Kingdom)

We demonstrate by using low-temperature high-resolution spectroscopy that red-shifted mutants of green fluorescent protein are photo-interconverted among three conformations and are, therefore, not...Full Text Available

2000-03-28

198

Optical sectioning of microbial biofilms.  

UK PubMed Central (United Kingdom)

Scanning confocal laser microscopy (SCLM) was used to visualize fully hydrated microbial biofilms. The improved rejection of out-of-focus haze and the increased resolution of SCLM made it preferable...Full Text Available

1991-10-01

199

Noise bias in the refinement of structures derived from single particles  

Energy Technology Data Exchange (ETDEWEB)

One of the main goals in the determination of three-dimensional macromolecular structures from electron microscope images of individual molecules and complexes (single particles) is a sufficiently high spatial resolution, about 4 A, at which the interpretation with an atomic model becomes possible. To reach high resolution, an iterative refinement procedure using an expectation maximization algorithm is often used that leads to a more accurate alignment of the positional and orientational parameters for each particle. We show here the results of refinement algorithms that use a phase residual, a linear correlation coefficient, or a weighted correlation coefficient to align individual particles. The algorithms were applied to computer-generated data sets that contained projections from model structures, as well as noise. The algorithms show different degrees of over-fitting, especially at high resolution where the signal is ...

2004-12-15

200

Noise Susceptibility of Cochlear Implant Users: The Role of Spectral Resolution and Smearing  

UK PubMed Central (United Kingdom)

The latest-generation cochlear implant devices provide many deaf patients with good speech recognition in quiet listening conditions. However, speech recognition deteriorates rapidly as the level of...Full Text Available

2005-03-01

201

NAME=\\  

Wastenet

... Buckeye rapidly produces high resolution imagery over a commander's area of interest contributing to intelligence, surveillance and reconnaissance, and also creates detailed mapping of the battlespace. BIG uses an innovative, original and creative combination of Web programming languages, Geographic Information Systems, and ...

202

NAME=\\  

Wastenet

...because it had greatly contributed to the geospatial capability of coalition forces in the Global War on Terrorism by producing a system that provides high-resolution imagery for use in detecting ground changes, creating detailed maps and obtaining Intelligence, Surveillance and Reconnaissance (ISR) information. ...

203

NAME=\\  

Wastenet

...Quality = $290,604 to improve permit compliance and appropriate preservation of wetlands by providing a spatial dataset to locate individual wetland permits on a property using high resolution imagery within specific regions of Virginia; this data set will be compared with the permit Comprehensive Environmental Database System that is currently used ...

204

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

205

Laser-assisted solar-cell metallization processing  

Energy Technology Data Exchange (ETDEWEB)

Laser assisted solar cell metallization processing which is a one step process is examined. The potential advantages of laser disposition techniques for photovoltaic systems are: a high resolution, no photolithography, clean and contamination free, in-situ sintering, and low contact resistance.

1984-03-01

206

Joint Research Centre - JRC - European Commission  

Wastenet

... The high resolution imagery , collected over Rio de Janeiro, Brazil, included a mixture of large commercial buildings and private houses, as well as the airport and some community parks. 10/08/11 Read more Top EU R&D companies expect a 5% ...

207

Ion beam pulsing for time of flight (TOF) experiments  

Energy Technology Data Exchange (ETDEWEB)

The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.

1985-01-01

208

Inferring transcription factor complexes from ChIP-seq data  

UK PubMed Central (United Kingdom)

Chromatin immunoprecipitation followed by high-throughput sequencing (ChIP-seq) allows researchers to determine the genome-wide binding locations of individual transcription factors (TFs) at high resolution....Full Text Available

2011-08-01

209

High-resolution sequence stratigraphic character and sandstone-type uranium ore formation. A case from Saihan Formation in Baiyinwula area, Erlian Basin  

International Nuclear Information System (INIS)

High-resolution sequence stratigraphy has been applied widely in the petroleum exploration and development, many achievements have been achieved. However, it is in the beginning stage that high-resolution sequence stratigraphy is applied to explore the sandstone-type uranium deposits in Erlian Basin. By applying principles of high-resolution sequence stratigraphy and taking typical boreholes as an example, sedimentary cycles of Saihan Formation, the ore-bearing formation in Baiyinwula area are divided and correlated through cross sections. One long-term cycle (LSC_1), two middle-term cycles (MSC_1, MSC_2) have been identified in this study. Based on this and combined with the mineralization character of sandstone uranium deposits in this area, it is presented that the interlayer oxidation zone is developed mainly in the rising hemicycle of MSC_1 and uranium ore bodies predominantly in channel sand bodies that were developed ...

2006-12-01

210

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of experiments. Real time radio-imagers ({beta}-imager and {mu}-imager) are preferred to verify experimental conditions. The {beta}--imager and s-imager are ...

2007-04-15

211

High resolution alpha-particle spectroscopy using CR-39 plastic track detector  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of alpha-particles as natural decay energy and from ...

1984-06-15

212

Gravitropism: Interaction of Sensitivity Modulation and Effector Redistribution 1  

UK PubMed Central (United Kingdom)

Our increasing capabilities for quantitative hormone analysis and automated high resolution growth studies have allowed a reassessment of the classical Cholodny-Went hypothesis of gravitropism. According...Full Text Available

1991-01-01

213

Further argument in support to the conjecture of a three-dimensional time  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a relativistic point kinematics with one independent dilation of (scalar) proper time for each spatial freedom degree would give a really rigorous physical significance to the ordinary logical resolution of the clock paradox between systems in relative motion.

1985-01-01

214

Exploration technology  

Energy Technology Data Exchange (ETDEWEB)

The paper evaluates exploration technology. Topics discussed are: Visions; the subsurface challenge; the creative tension; the exploration process; seismic; geology; organic geochemistry; seismic resolution; integration; drilling; value creation. 4 refs., 22 figs.

1996-12-31

215

Epilogue - GES DISC - NASA  

Science.gov (United States)

Sep 9, 2009... a French Ariane rocket successfully launched a new Earth-observing satellite ... The payload is a pair of identical sensors known as "high-resolution ... the resulting image) are activated simultaneously by incoming radiation; ...

216

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of ...

1998-06-01

217

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction ...

2007-01-01

218

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

219

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

220

Detailed comparison of the structures and kinematics of simulated and observed barred galaxies  

CERN Document Server

We examine the observable properties of simulated barred galaxies including radial mass profiles, edge-on structure and kinematics, bar lengths and pattern speed evolution for detailed comparison to real systems. We have run several simulations in which bars are created through inherent instabilities in self-consistent simulations of a realistic disc+halo galaxy model with a disc-dominated, flat rotation curve. These simulations were run at high (N=20M particles) and low (N=500K) resolution to test numerical convergence. We determine the pattern speeds in simulations directly from the phase angle of the bar versus time and the Tremaine-Weinberg method. Fundamental dynamics do not change between the high and low resolution, suggesting that convergence has been reached in this case. We find the higher resolution is needed to simulate structural and kinematic properties accurately. The edge-on view of the ...

2003-01-01

221

Crystal structure of the human adenovirus proteinase with its 11 amino acid cofactor.  

UK PubMed Central (United Kingdom)

The three-dimensional structure of the human adenovirus-2 proteinase complexed with its 11 amino acid cofactor, pVIc, was determined at 2.6 A resolution by X-ray crystallographic analysis. The fold...Full Text Available

1996-04-15

222

Bragg curves of fission fragments in gases  

Energy Technology Data Exchange (ETDEWEB)

An unexpectedly high probability of collisions between the fission particles and the atoms in an ionization chamber along the entire particle track causes a strong fluctuation of the shapes of the Bragg curves. This fluctuation imposes an upper limit of the charge resolution ..delta..Z/Z which can be achieved.

1986-03-01

223

Application of low-resolution Raman spectroscopy for the analysis of oxidized olive oil  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the potential of low-resolution Raman spectroscopy for monitoring the oxidation status of olive oil. Primary and secondary oxidation parameters such as peroxide value, K"2"3"2 and K"2"7"0 were studied. Low-resolution Raman spectra ranging from 200 to 2700 cm^-^1 in a set of 126 oxidized and virgin olive oil samples were collected directly using a probe. Partial Least Squares was used to calibrate the Raman instrument for the different targeted parameters. The performance of the models was determined by using validation sets, and the best results obtained were: R^2 = 0.91, RMSEP = 2.57 for the peroxide value content; R^2 = 0.88, RMSEP = 0.37 for K"2"3"2; and R^2 = 0.90, RMSEP = 0.08 for K"2"7"0. These results demonstrated that low-resolution Raman spect...

2011-01-01

224

An unsupervised classification method for inferring original case locations from low-resolution disease maps  

UK PubMed Central (United Kingdom)

BackgroundWidespread availability of geographic information systems software has facilitated the use of disease mapping in academia, government and private sector. Maps that display...Full Text Available

225

APOD: January 25, 1997 - M51: The Whirlpool Galaxy  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy Credit: W. Keel (U. Alabama), 1.1-meter Hall Telescope, Lowell Observatory...

2011-10-07

226

APOD: December 18, 1995 - M51: The Whirlpool Galaxy  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy Credit: 1.1 Meter Hall Telescope, Lowell Observatory, Bill Keel (U. Alabama)...

2011-10-07

227

APOD: 2011 January 26 - The Whirlpool Galaxy in Infrared Dust  

Science.gov (United States)

Clicking on the image will bring up the highest resolution version available. The Whirlpool Galaxy in Infrared Dust Credit: Infrared: NASA, ESA, M. Regan & B. Whitmore (STScI),...

2011-10-07

228

APOD: 2006 November 11 - M51: Cosmic Whirlpool  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: Cosmic Whirlpool Credit: S. Beckwith (STScI) Hubble Heritage Team, (STScI/AURA), ESA, NASA...

2011-10-07

229

APOD: 2005 April 28 - M51: Cosmic Whirlpool  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: Cosmic Whirlpool Credit: S. Beckwith (STScI) Hubble Heritage Team, (STScI/AURA), ESA, NASA...

2011-10-07

230

APOD: 2004 September 5 - M51: The Whirlpool Galaxy in Dust and...  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy in Dust and Stars Credit: Credit: N. Scoville (Caltech), T. Rector (U....

2011-10-07

231

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

232

APOD: 2001 April 10 - M51: The Whirlpool Galaxy in Dust and Stars  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy in Dust and Stars Credit: N. Scoville (Caltech), T. Rector ( (NOAO) et al.,...

2011-10-07

233

APOD: 2000 May 27 - M51: The Center Of The Whirlpool  

Science.gov (United States)

will download the highest resolution version available. M51: The Center Of The Whirlpool Credit: N. Panagia (STScI, ESA), NASA Explanation: In the center of M51, a spiral...

2011-10-07

234

14 - NASA  

Science.gov (United States)

... and mean rainfall rates, Rm, in the liquid hydrometeor layers using the .... large latitudinal movement of cirrus cloud cover with the changing seasons. ... We study the statistical distribution of PSCs by particle composition using .... the high resolution Cloud Particle Imager (CPI) and standard PMS 2D-C and ...

235

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

236

The ANL X6B beamline at NSLS: A versatile facility  

Energy Technology Data Exchange (ETDEWEB)

We have described the x-ray optics and beamline performance of the ANL X6B beam line at the NSLS. Considerable flexibility has been built into the beam line to accommodate a wide range of x-ray diffraction, scattering, and spectroscopy experiments with various requirements. We presented selected examples of experimental results and showed that with the high intensity, high energy resolution, high-q resolution, and energy tunability, the X6B beam line has become a versatile facility.

1994-07-01

237

Resolution s/n it approves the proposal by the National Directorate of Energy and Nuclear Technology in the terms set out in the working groups mentioned  

International Nuclear Information System (INIS)

The following Resolution has been stated because of the results of the workshops Elaboration of proposals for strategic guidelines held from 2 to May 5, 2006, elaboration of proposals for the Strategic Lines instruments held from 24 to July 28, 2006, as well as documents Proposal of politic energetic Uruguayan Energy Sector development and proposal of Energy Policy Instruments developed by the National Directorate of Nuclear Energy and Technology and the Energy Strategy Guidelines Uruguay 2006.

2006-10-12

238

Production of a helium beam in a focused ion beam machine using an electron beam ion trap  

International Nuclear Information System (INIS)

Gallium liquid-metal ion sources that have been introduced in the late 1970s have allowed the development of a new class of micro- and nanofabrication tools collectively denominated as focused ion beam (FIB) machines. To investigate the potential of a helium beam in such a FIB instrument the authors have tested a room-temperature electron beam ion trap coupled with a high resolution FIB machine. In this letter they present their first results in target imaging using a helium beam with a resolution that allows to account for a beam diameter in the submicrometer range.

2007-02-19

239

Large solid angle Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.

1984-02-01

240

In-beam #gamma#-ray spectroscopy of fast beams at the NSCL  

International Nuclear Information System (INIS)

With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.

2004-04-05

241

High resolution transmission electron microscopy of partial states of oxygen order in YBa_2Cu_3O_z  

International Nuclear Information System (INIS)

This paper reports on high resolution electron microscopy used to investigate the effect of electron irradiation induced oxygen loss on the states of partial order in YBa_2Cu_3O_z. Contrast effects visible in the [001] zone image as a result of the degree of the out-of-plane correlation of these ordered states are investigated. Using statistical simulations to aid in the analysis of the HREM images, an interpretation based on a kinetically limited evolution of the variation of long range [001] ordering is proposed.

1990-04-16

242

High Resolution Eddy Current Probes for Non Destructive Testing  

Science.gov (United States)

New industrial Non Destructive Testing requires the development of new probes: technologies such as high spatial resolution probes for small breaking flaws detection or flexible probes for complex curved surfaces inspection. The CEA/LIST has designed and integrated 2 probes to answer industrial's constraints. The first one is based on Giant Magneto-Resistance and is able to detect 50 ?m3 flaws. The second one is based on micro-coils etched on kapton and its flexibility is adapted to curved surfaces inspection. Both are multi-elements probes, allowing fast inspection. This paper presents those new probes, their design and their performances.

2008-02-01

243

Gaussian models for genetic linkage analysis using complete high-resolution maps of identity by descent  

Energy Technology Data Exchange (ETDEWEB)

Gaussian-process models are developed to detect genetic linkage using complete high-resolution maps of identity by descent between affected relative pairs. Approximations are given for the significance level and power of the likelihood-ratio test of no linkage and for likelihood-ratio confidence regions for trait loci. The sample sizes required to detect linkage by using different classes of affected relative pairs are compared, and the problem of combining data from different classes of relatives is discussed. 23 refs., 2 figs.

1993-07-01

244

FADC signal reconstruction for the MAGIC telescope  

Energy Technology Data Exchange (ETDEWEB)

Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.

2008-09-11

245

Bragg-curve spectroscopy detector  

Energy Technology Data Exchange (ETDEWEB)

In an ionization chamber with the electric field parallel to the particle trajectories, the time dependence of the anode signal contains all the information about the energy and the nuclear charge of the ionizing particle. By proper pulse shaping with a long and a short time constant the total ionization charge and the ionization charge integrated around the Bragg maximum, respectively, can be obtained. The former signal is proportional to the total energy, whereas the latter allows the nuclear charge to be deduced directly. An energy resolution of 0.4% and a Z resolution ..delta..Z/Z = 1/82 was achieved for 130 MeV /sup 32/S ions and argon-methane as the stopping medium.

1982-02-01

246

Investigation of techniques to improve continuous air monitors under conditions of high dust loading in environmental setting. 1998 annual progress report  

Energy Technology Data Exchange (ETDEWEB)

'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and 1.0 \\265m Corning ...

1998-06-01

247

U.V. repair in deep-sea bacteria  

International Nuclear Information System (INIS)

Exposure of cells to light of less than 320 nanometers wavelengths may lead to lethal lesions and perhaps carcinogenesis. Many organisms have evolved mechanisms to repair U.V. light-induced damage. Organisms such as deep-sea bacteria are presumably never exposed to U.V. light and perhaps occasionally to visible from bioluminescence. Thus, the repair of U.V. damage in deep-sea bacterial DNA might be inefficient and repair by photoreactivation unlikely. The bacteria utilized in this investigation are temperature sensitive and barophilic. Four deep-sea isolates were chosen for this study: PE-36 from 3584 m, CNPT-3 from 5782 m, HS-34 from 5682 m, and MT-41 from 10,476 m, all are from the North Pacific ocean. The deep-sea extends from 1100 m to depths greater than 7000 m. It is a region of relatively uniform conditions. The temperature ranges from 5 to -1"0C. There is no solar light in the deep-sea. Deep-sea bacteria are sensitive to U.V. light; in fact more sensitive ...

1986-06-08

248

Study on grain growth of fine grained WC-Co hardmetal by numerical calculation  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews our simulation study by numerical calculation based on two-, three- and multi-grain-size models on WC grain growth in fine grained WC-Co hardmetal doped with VC. The study aimed to presume or predict the following: (1) the cause and conditions for the abnormal grain growth which occurs in some cases in the fine grained hardmetal prepared from fine WC powders with mean grain size below about 0.2{mu}m, and (2) how the mean grain size of the hardmetal varies with decreasing mean grain size of the WC starting powder to 0.1 pm or nano-meter size. The calculation results by these three kinds of models suggested the following, respectively: (1) the occurrence of the abnormal grain growth is generally substantial for WC starting powder with bimodal size-distribution and mean gram size below 0.1 - 0.2{mu}m, and not due to the non-uniform distribution of the grain growth inhibitor, (2) the introduction of middle grains caused the disappearance of small ...

2000-12-15

249

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using accelerator beam, the dose distribution in the biological substances is ...

2003-08-17

250

Novel pseudo-morphotactic synthesis and characterization of tungsten nitride nanoplates  

International Nuclear Information System (INIS)

A novel pseudo-morphotactic transformation route was developed to synthesize polycrystalline ?-W2N nanoplates by thermally treating tungstate-based inorganic-organic hybrid nanobelts with a lamellar microstructure in an NH3 flow. The tungstate-based hybrid nanobelts were formed in a water-in-oil-microemulsion-like 'commercial H2WO4 powders/n-octylamine/heptane' reaction system. The as-obtained hybrid nanobelts were thermally treated in an NH3 atmosphere at 650-800 oC for 2 h to form cubic ?-W2N nanoplates. XRD, SEM, TEM, FT-IR and TG-DTA were used to characterize the precursors and their final products. The polycrystalline ?-W2N nanoplates derived from hybrid nanobelts, with side lengths of several hundred nanometers, consist of small nanocrystals with an average grain size of 3.2 nm. The formation of ?-W2N nanoplates involved two steps: decomposing tungstate-based hybrid nanobelts into WOy and W species and then nitridizing the active W-containing species to ?-W2N ...

2011-02-01

251

Focus ion beam preparation of transmission electron microscope sample in polymer clay nano composite  

International Nuclear Information System (INIS)

This paper deals with preparation of PE clay nano composite specimen for transmission electron microscopy (TEM) and studying the difference between dispersion of clay in low density polyethylene using poly(hydrogen methyl siloxane) (PHMS) as coupling agent and untreated one. Argon ion milling is the conventional means by which film sections are thinned to electron transparency for TEM analysis, but this technique exhibits significant problems. In particular, selective thinning and imaging of sub-micrometer inclusions during sample milling are highly problematic. We have achieved successful results using the focused ion beam (FIB) lift-out technique, which utilizes a 30 kV Ga"+ ion beam to extract electron transparent specimens with nanometer scale precision. Using this procedure, we have prepared a number of thin film materials representing a range of structures and compositions for TEM analysis. We believe that FIB milling will create major new opportunities in ...

2006-01-01

252

Enzyme-induced growth of silver nanoparticles studied on single particle level  

Energy Technology Data Exchange (ETDEWEB)

Based on their interesting properties, metal nanoparticles show the potential as an analytical tool in electronic (Burmeister et al. 2004), optical (Yguerabide and Yguerabide 1998), and catalytic applications (Liu 2006). Their characteristics depend on the composition, shape, and size of the single particles. These various properties are utilized in many different approaches such as optics, magnetics (Lang et al. 2007), and laser technology (Csaki et al. 2007). We investigated an alternative method for the synthesis of nanoparticles. In this case, an enzyme, horseradish peroxidase, induces a silver deposition and replaces a metal nanoparticle as the reaction seed. Depending on the reaction time, we could obtain particles in a range of few nanometers up to more than 250 nm. For a better understanding of the enzymatic silver deposition process, the silver particles produced by this process were analyzed by SEM, TEM, and atomic force microscopy (AFM) on a single ...

2009-05-15

253

Diffusion in silicon isotope heterostructures  

Science.gov (United States)

The simultaneous diffusion of Si and the dopants B, P, and As has been studied by the use of a multilayer structure of isotopically enriched Si. This structure, consisting of 5 pairs of 120 nm thick natural Si and {sup 28}Si enriched layers, enables the observation of {sup 30}Si self-diffusion from the natural layers into the {sup 28}Si enriched layers, as well as dopant diffusion from an implanted source in an amorphous Si cap layer, via Secondary Ion Mass Spectrometry (SIMS). The dopant diffusion created regions of the multilayer structure that were extrinsic at the diffusion temperatures. In these regions, the Fermi level shift due to the extrinsic condition altered the concentration and charge state of the native defects involved in the diffusion process, which affected the dopant and self-diffusion. The simultaneously recorded diffusion profiles enabled the modeling of the coupled dopant and self-diffusion. From the modeling of the simultaneous diffusion, the dopant diffusion ...

2004-05-14

254

Development of experimental verification techniques for non-linear deformation and fracture on the nanometer scale.  

Energy Technology Data Exchange (ETDEWEB)

This work covers three distinct aspects of deformation and fracture during indentations. In particular, we develop an approach to verification of nanoindentation induced film fracture in hard film/soft substrate systems; we examine the ability to perform these experiments in harsh environments; we investigate the methods by which the resulting deformation from indentation can be quantified and correlated to computational simulations, and we examine the onset of plasticity during indentation testing. First, nanoindentation was utilized to induce fracture of brittle thin oxide films on compliant substrates. During the indentation, a load is applied and the penetration depth is continuously measured. A sudden discontinuity, indicative of film fracture, was observed upon the loading portion of the load-depth curve. The mechanical properties of thermally grown oxide films on various substrates were calculated using two different numerical methods. The first method utilized a plate bending ...

2005-11-01

255

Biomimetic helical rosette nanotubes and nanocrystalline hydroxyapatite coatings on titanium for improving orthopedic implants  

Science.gov (United States)

Natural bone consists of hard nanostructured hydroxyapatite (HA) in a nanostructured protein-based soft hydrogel template (ie, mostly collagen). For this reason, nanostructured HA has been an intriguing coating material on traditionally used titanium for improving orthopedic applications. In addition, helical rosette nanotubes (HRNs), newly developed materials which form through the self-assembly process of DNA base pair building blocks in body solutions, are soft nanotubes with a helical architecture that mimics natural collagen. Thus, the objective of this in vitro study was for the first time to combine the promising attributes of HRNs and nanocrystalline HA on titanium and assess osteoblast (bone-forming cell) functions. Different sizes of nanocrystalline HA were synthesized in this study through a wet chemical precipitation process following either hydrothermal treatment or sintering. Transmission electron microscopy images showed that HRNs aligned with nanocrystalline HA, which ...

2008-01-01

256

The application of high resolution sequence stratigraphy to reservoir zonation and management of the Beryl Field  

Energy Technology Data Exchange (ETDEWEB)

Tidally dominated sections from the Middle Jurassic Beryl Formation of the Beryl Field, Viking Graben (UKCS) were deposited during rapid changes in relative sea level. High density well coverage in this key producing interval has allowed the construction of an integrated high resolution sequence stratigraphic scheme based on sedimentological, ichnofaunal, wireline, biostratigraphic and engineering data. From this database a number of high resolution sequences in the Bajocian-Bathonian Beryl Formation have been identified composed of interbedded sandstones, siltstones and mudstones. These sediments formed tidally-influenced deltas and estuaries deposited in actively subsiding half-grabens during regionally extensive base-level changes. For reservoir management purposes, the formation has been split into 5 units. The thickest interval, Unit 3, is considered here. In the northern part of the Beryl Field, Unit 3 is bounded above and below by ...

1996-08-01

257

Groundwater penetrating radar and high resolution seismic for locating shallow faults in unconsolidated sediments  

Energy Technology Data Exchange (ETDEWEB)

Faults in shallow, unconsolidated sediments, particularly in coastal plain settings, are very difficult to discern during subsurface exploration yet have critical impact to groundwater flow, contaminant transport and geotechnical evaluations. This paper presents a case study using cross-over geophysical technologies in an area where shallow faulting is probable and known contamination exists. A comparison is made between Wenner and dipole-dipole resistivity data, ground penetrating radar, and high resolution seismic data. Data from these methods were verified with a cone penetrometer investigation for subsurface lithology and compared to existing monitoring well data. Interpretations from these techniques are compared with actual and theoretical shallow faulting found in the literature. The results of this study suggests that (1) the CPT study, combined with the monitoring well data may suggest that discontinuities in correlatable zones may indicate that faulting ...

1993-12-31

258

Trade-off between angular resolution and straylight contamination in CMB anisotropy experiments. II. Straylight evaluation  

CERN Document Server

Satellite CMB anisotropy missions and new generation of balloon-borne and ground experiments, make use of complex multi-frequency instruments at the focus of a meter class telescope. Between 70 GHz and 300 GHz, where foreground contamination is minimum, it is extremely important to reach the best trade-off between the improvement of the angular resolution and the minimization of the straylight contamination mainly due to the Galactic emission. We focus here, as a working case, on the 30 and 100 GHz channels of the Planck Low Frequency Instrument (LFI). We evaluate the GSC introduced by the most relevant Galactic foreground components for a reference set of optical configurations. We show that it is possible to improve the angular resolution of 5-7% by keeping the overall GSC below the level of few microKelvin. A comparison between the level of straylight introduced by the different Galactic components for different beam regions is presented. ...

2003-01-01

259

The Complex Interstellar Na I Absorption toward h and Chi Persei  

CERN Document Server

Recent high spatial and spectral resolution investigations of the diffuse interstellar medium (ISM) have found significant evidence for small-scale variations in the interstellar gas on scales less than or equal to 1 pc. To better understand the nature of small-scale variations in the ISM, we have used the KPNO WIYN Hydra multi-object spectrograph, which has a mapping advantage over the single-axis, single-scale limitations of studies using high proper motion stars and binary stars, to obtain moderate resolution (~12 km/s) interstellar Na I D absorption spectra of 172 stars toward the double open cluster h and Chi Persei. All of the sightlines toward the 150 stars with spectra that reveal absorption from the Perseus spiral arm show different interstellar Na I D absorption profiles in the Perseus arm gas. Additionally, we have utilized the KPNO Coude Feed spectrograph to obtain high-resolution (~3 km/s) interstellar Na I D ...

2004-01-01

260

The Application of High Resolution Sequence Stratigraphy for Understanding the Hydrocarbon Prospectivity of the Moere and Southern Voering Basins  

Energy Technology Data Exchange (ETDEWEB)

The deep water parts of the Moere and Southern Voering Basins are large frontier areas, which are considered to contain significant undiscovered hydrocarbon resources, within Cretaceous and Paleogene reservoirs. PGS Reservoir AS have evaluated the Cretaceous and Paleogene successions of the shallow and deep water areas offshore Mid-Norway using high-resolution sequence stratigraphic techniques. The successions have been subdivided into about 20 stratigraphic sequences. The results are: (1) A more acurate and higher resolution stratigraphy, (2) Greater constraints on basin palaeoenvironmental and palaeogeographic reconstructions, (4) Fully integrated sandstone fairway models, with increased ability to reservoir and seal quality and continuity, (5) In addition to several obvious giant domal traps, subtler yet significant structural and stratigraphic leads and prospects can be identified, (6) The timing, volume and phase of hydrocarbon generation ...

1999-07-01

261

Reverse time migration: resolution in cross well seismic surveys; Migracao reversa no tempo: resolucao em levantamentos sismicos interpocos  

Energy Technology Data Exchange (ETDEWEB)

The standards mapping methods are limited by the lack of information between surface measures and wells profiles. The cross well seismic survey has proven being an effective high-resolution method for reservoirs characterization due its high frequency band. In this work, a 2-D finite differences algorithm for numerical cross well seismic simulation was developed, based in the approach of 2nd order for the time derivatives and 4th order for the space derivatives. In relation to the imaging techniques, it was introduced a reverse time migration method based in the solutions of the wave equation in time for cross well seismic data by the method of the finite differences exclusively. The results of reverse time migration has showed that layers with 90 cm thickness for P-waves could be visualized in migrated sections with excellent resolution. The high frequency cross well seismic data combined with reverse time migration have the potential for ...

2003-07-01

262

Relation between frequency of seismic wave and resolution of tomography; Danseiha tomography kaiseki ni okeru shuhasu to bunkaino no kankei  

Energy Technology Data Exchange (ETDEWEB)

With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring according to ...

1997-05-27

263

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma ...

2000-01-01

264

Pseudocraters as indicators of ground ice on Mars  

International Nuclear Information System (INIS)

Positive identification of Martian pseudocraters would be a strong indication of past occurrence of ice at or near the surface of Mars. The basis for suggesting that small cones on Mars are pseudocraters includes: (1) small size, (2) abundant but patchy distribution on what appear to be volcanic plains, (3) presence of other features suggestive of surface or subsurface ice, (4) morphological similarities to Icelandic pseudocraters, and (5) the similarity in distribution of crater/cone diameter ratios to Icelandic pseudocraters. This last morphometric parameter may be the most important, since other possible small terrestrial volcanic analogs have very different crater/cone diameter ratio distributions. In a survey of the available high resolution Viking Orbiter imagery, abundant fields of possible pseudocraters were found. However, only a small fraction of the plains forming units imaged at high resolution were found to contain the small cones. ...

1987-05-01

265

Position sensitive and Bragg curve spectroscopy detector system  

Energy Technology Data Exchange (ETDEWEB)

A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/..delta..Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/..delta..Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane coordinate within ...

1984-08-01

266

Position sensitive and Bragg curve spectroscopy detector system  

International Nuclear Information System (INIS)

A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/#DELTA#Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/#DELTA#Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane coordinate within +-0.5 ...

267

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...

268

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate behavior, and excellent mass resolution over a large energy range were essential.

1988-12-01

269

Final report for the 'Melt-Vessel Interactions' Project. European Union R and TD Program 4th Framework. MVI project final research report  

International Nuclear Information System (INIS)

The Melt Vessel Interaction (MVI) project is concerned with the consequences of the interactions that a core melt, generated during a postulated severe accident in a light water reactor, may have with the pressure vessel. In particular, the issues concerned with the failure of the vessel bottom head are the focus of the research. The specific objectives of the project are to obtain data and develop validated models, which could be applied to prototypic plants, and accident conditions, for resolution of issues related to the melt vessel interactions. The project work has been performed by nine partners having varied responsibility. The work included a large number of experiments, with simulant materials, whose observations and results are employed, respectively, to understand the physical mechanisms and to develop validated models. Applications to the prototypic geometry and conditions have also been performed. This report is volume 1 of the Final Report for the ...

1995-10-01

270

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through 3-dimensional depth sensing. Two types of ...

2004-01-01

271

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

Energy Technology Data Exchange (ETDEWEB)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of [Delta][epsilon] = 1.3 [mu]eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T[sub m] (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T[sub m]. Quasielastic broadening in the spectrum at Q = 0.082 A[sup -1] is observed only above 210degC, which is 75degC higher than the T[sub m]. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 [mu]eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

1992-06-01

272

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

International Nuclear Information System (INIS)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of #DELTA##epsilon# = 1.3 #mu#eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T_m (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T_m. Quasielastic broadening in the spectrum at Q = 0.082 A"-"1 is observed only above 210degC, which is 75degC higher than the T_m. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 #mu#eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

273

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters  

International Nuclear Information System (INIS)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as ...

274

Wave extrapolation in the spatial wavelet domain with application to poststack reverse-time migration  

Energy Technology Data Exchange (ETDEWEB)

A wavelet transformation is performed over each of the spatial coordinates of the scalar wave equation. This transformed equation is solved directly with a finite-difference scheme for both homogeneous and smooth inhomogeneous media. Wavefield extrapolation is performed completely in the spatial wavelet domain without transforming back into the space domain at each time step. The wavelet coefficients are extrapolated, rather than the wavefield itself. The numerical solution of the scalar wave equation in the spatial wavelet domain is closely related to the finite-difference method because of the compact support of the wavelet bases. Poststack reverse-time migration is implemented as an application. The resolution spaces of the wavelet transform provide a natural framework for multigrid analysis. Migrated images are constructed from various resolution spaces.

1998-03-01

275

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

276

The mass dependence of the signal peak height of a Bragg-curve ionization chamber  

International Nuclear Information System (INIS)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).

277

The Brazilian Bragg curve detector built for AMS studies  

Energy Technology Data Exchange (ETDEWEB)

A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.

2000-10-01

278

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

279

Structure of Mgn and Mg n + clusters up to n = 30  

British Library Electronic Table of Contents (United Kingdom)

We present structure calculations of neutral and singly ionized Mg clusters of up to 30 atoms, as well as Na clusters of up to 10 atoms. The calculations have been performed using density functional theory (DFT) within the local (spin-)density approximation, ion cores are described by pseudopotentials. We have utilized a new algorithm for solving the Kohn-Sham equations that is formulated entirely in coordinate space and, thus, permits straightforward control of the spatial resolution. Our numerical method is particularly suitable for modern parallel computer architectures; we have thus been able to combine an unrestricted simulated annealing procedure with electronic structure calculations of high spatial resolution, corresponding to a plane-wave cutoff of 954 eV for Mg. We report the geo...

2011-01-01

280

Selection of ancillary data to derive production management units in sweet corn (Zea Mays var. rugosa) using MANOVA and an information criterion  

British Library Electronic Table of Contents (United Kingdom)

In production systems where high-resolution harvest data are unavailable there is often a reliance on ancillary information to generate potential management units. In these situations correct identification of relevant sources of data is important to minimize cost to the grower. For three fields in a sweet corn production system in central NSW, Australia, several sets of high-resolution data were obtained using soil and crop canopy sensors. Management units were derived by k-means classification for 2?5 classes using three approaches: (1) with soil data, (2) with crop data and (3) a combination of both soil and crop data. Crop quantity and quality were sampled manually, and the sample data were related to the different management units using multivariate analysis of variance (MANOVA). The ...

2011-01-01

281

Seismic stratigraphy in high resolution shallow marine seismic data of the Gemlik Gulf  

Energy Technology Data Exchange (ETDEWEB)

Seismic stratigraphy and sedimentological studies of the Gemlik Gulf in the Sea of Marmara, Turkey, have been carried out. For this purpose, 19 lines totaling 189 km of excellent quality, high-resolution seismic data were recorded. Four major acoustic units were identified in the seismic profiles. Three were sedimentary units: irregular layered, cross-layered and well-layered; and the fourth was an acoustic basement which is probably composed of crystalline volcanic rocks. Some local areas in the Neogene formation contain gas accumulations. The formation of faults in E--W and N--S directions can be explained by the existence of shear stresses in the Gulf. The bathymetric map shows good accommodation with the shore line as does the tectonic map.

1993-10-01

282

Role of MRI in the diagnostic evaluation of parotid diseases  

International Nuclear Information System (INIS)

MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the tumor extent.

1988-01-01

283

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

284

Quantitation of Cellular Dynamics in Growing Arabidopsis Roots with Light Sheet Microscopy  

CERN Document Server

To understand dynamic developmental processes, living tissues must be imaged frequently and for extended periods of time. Root development is extensively studied at cellular resolution to understand basic mechanisms underlying pattern formation and maintenance in plants. Unfortunately, ensuring continuous specimen access, while preserving physiological conditions and preventing photo-damage, poses major barriers to measurements of cellular dynamics in indeterminately growing organs such as plant roots. We present a system that integrates optical sectioning through light sheet fluorescence microscopy with hydroponic culture that enables us to image at cellular resolution a vertically growing Arabidopsis root every few minutes and for several consecutive days. We describe novel automated routines to track the root tip as it grows, track cellular nuclei and identify cell divisions. We demonstrate the system's capabilities by collecting data on ...

2011-01-01

285

Quantification of order in the liquid at a solid-liquid interface by High-Resolution Transmission Electron Microscopy (HRTEM)  

Energy Technology Data Exchange (ETDEWEB)

A number of different theoretical approaches have been used to model to atomic structure and properties of solid-liquid interfaces. Most calculations indicate that ordering occurs in the first several layers of the liquid, adjacent to the crystal surface. In contrast to the numerous theoretical investigations, there have been no direct experimental observations of the atomic structure of a solid-liquid interface for comparison. Saka et al. examined solid-liquid interfaces in In and In-Sb at lattice-fringe resolution in the TEM, but their data do not reveal information about the atomic structure of the liquid phase. The purpose of this study is to determine the atomic structure of a solid-liquid interface using a highly viscous supercooled liquid, i.e., a crystal-amorphous interface.

1996-12-31

286

Performance of a Bragg curve detector for heavy ion identification  

Energy Technology Data Exchange (ETDEWEB)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.

1982-12-15

287

Performance of a Bragg curve detector for heavy ion identification  

International Nuclear Information System (INIS)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).

288

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

289

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared with direct beam profile measurements.

2009-02-11

290

Measurement of fission cross sections for nuclear transmutation on Am-241, Am-242m and Am-243 using lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)

1997-12-31

291

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.

1998-08-01

292

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)

1999-02-01

293

Mass dependence of the signal peak height of a Bragg-curve ionization chamber  

Energy Technology Data Exchange (ETDEWEB)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.

1985-01-01

294

Investigations of microstructure of thin TbFeCo films by high-resolution electron microscopy  

International Nuclear Information System (INIS)

High-resolution electron microscope observations confirm the presence of small crystallites in thin TbFeCo films protected by Si_3N_4 overcoats. Selected area electron diffraction patterns in top-view projection indicate that the crystals have a face-centered-cubic structure. Microscope analysis reveals grain growth following annealing of these protected thin films at 200 degree C in vacuum, and Kerr measurements yield large reductions in coercivity relative to the room-temperature value. The typical grain size visible in top-view observations increases from about 3 nm in the as-deposited samples to about 30 nm after annealing at 200 degree C for 36 h while the static coercivity, H_c, drops by about 40%. The fcc structure of the crystals is retained after annealing.

295

Influence of intracavity doppler frequency shift in the swept-cavity ringdown spectroscopy incorporating continuous-wave laser excitation  

International Nuclear Information System (INIS)

Cavity ringdown spectroscopy (CRDS) with continuous-wave (cw) laser excitation has added high frequency resolution to the ability of CRDS being used for the absolute quantification of trace-level species present in many chemical processes. Cavity dithering technique has easily resolved the problem of resonant coupling of a cw laser light into a high-finesse cavity. The present study addresses the potential uncertainty involved in such cw-CRDS techniques incorporating the cavity mirror motion, i.e., the doppler frequency shift of a probe light inside the cavity. In the high-resolution spectroscopic work of megahertz-accuracy, even the influence of intracavity doppler effect may become significant.

2001-11-01

296

High-resolution spectroscopy of Er{sup 3+} ions in 6H SiC  

Energy Technology Data Exchange (ETDEWEB)

In this work, we present results of a systematic study of optical properties of Er{sup 3+} ions in 6H SiC. The role of N-donors played in activation of photoluminescence (PL) of erbium at 1.5 {mu}m was investigated. We have confirmed that N-donors are necessary for activation of the Er PL on one hand, whereas on the other we present evidence that N-donors compete for excitation with Er centres. The high-resolution measurements of the Er{sup 3+} PL were performed aiming at determination of crystal field split levels of the {sup 4}I{sub 15/2} ground and {sup 4}I{sub 13/2} first excited multiplet of Er{sup 3+} ions. Careful analysis of temperature evolution of individual PL lines allowed proposing energy level schemes for the ground and first excited states.

2003-12-15

297

High-resolution spectroscopy of Er"3"+ ions in 6H SiC  

International Nuclear Information System (INIS)

In this work, we present results of a systematic study of optical properties of Er"3"+ ions in 6H SiC. The role of N-donors played in activation of photoluminescence (PL) of erbium at 1.5 #mu#m was investigated. We have confirmed that N-donors are necessary for activation of the Er PL on one hand, whereas on the other we present evidence that N-donors compete for excitation with Er centres. The high-resolution measurements of the Er"3"+ PL were performed aiming at determination of crystal field split levels of the "4I_1_5_/_2 ground and "4I_1_3_/_2 first excited multiplet of Er"3"+ ions. Careful analysis of temperature evolution of individual PL lines allowed proposing energy level schemes for the ground and first excited states.

2003-12-15

298

High-resolution sequence stratigraphic framework and its characteristic. Case study of C-P coal measures in Hebei  

Energy Technology Data Exchange (ETDEWEB)

The framework of time-sequence stratigraphy was established according to the point of view of high-resolution sequence stratigraphy. The development characteristic of the sequence, the distribution pattern of strata, the basin evolution and filling, and the relationship between variations of base level and coal accumulation of epicontinental basin were expounded based on the base-level cycles. The result shows that the C-P coal measures in Hebei is a series of basin deposit of inner epicontinental sea. The formation and evolution and sedimentation of the basin is intimately related to the changes of the basin base-level, which controls the development of the coal-accumulation, forming a clear coal-bearing sequence in the cycle. 9 refs., 3 figs.

2001-07-01

299

High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.

1990-01-01

300

High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.

1990-12-31

301

High resolution electron microscopy study of as-prepared and annealed tungsten-carbon multilayers  

International Nuclear Information System (INIS)

A series of sputtered tungsten-carbon multilayer structures with periods ranging from 2 to 12 nm in the as-prepared state and after annealing at 500 degrees C for 4 hours has been studied with high resolution transmission electron microscopy. The evolution with annealing of the microstructure of these multilayers depends on their period.As-prepared structures appear predominantly amorphous from TEM imaging and diffraction. Annealing results in crystallization of the W-rich layers into WC in the larger period samples, and less complete or no crystallization in the smaller period samples. X-ray scattering reveals that annealing expands the period in a systematic way. The layers remain remarkably well-defined after annealing under these conditions.

302

High resolution X ray spectroscopy in light antiprotonic atoms  

Energy Technology Data Exchange (ETDEWEB)

At the LEAR facility, CERN, antiprotonic L{alpha} transitions in light elements have been investigated with a focussing crystal spectrometer. The high resolution of the experiment allowed for the first time to resolve in p-barH the 2{sup 3}P{sub 0} state from the close lying states 2{sup 3}P{sub 2}, 2{sup 1}P{sub 1}, and 2{sup 3}P{sub 1}. In p-barD the corresponding transitions were found to be more than an order of magnitude broader. To a large extent the results for p-barH support the meson exchange model.

2000-08-15

303

Free field resolution for nonunitary representations of N=2 SuperVirasoro  

CERN Document Server

We study N=2 SuperVirasoro SCFT for the generic value of the central charge. The main tool is the nonstandard bosonisation suggested in \\ref\\rRoz{L. Rozansky a letter to M. Bershadsky, 1989}, \\ref\\rSeBGR{B. Gato-Rivera, A. Semikhatov Phys. Letts. B293 (1992) 72},\\ref\\rBLNW{M. Bershadsky, W. Lerche, D. Nemeshansky, N. Warner N=2 Extended superconformal structure of Gravity and W Gravity coupled to Matter HUTP-A034/92}. The free field resolutions for the irreducible representations are obtained; the characters of these representations are computed. The quantum hamiltonian reduction from the Kac-Moody $\\hat{sl}_k(2|1)$ to N=2 $SVir$ is constructed.

1993-01-01

304

Focused ion beam fabrication and properties of nanoscale Josephson junctions for sensors and other applications  

International Nuclear Information System (INIS)

The methods of superconducting device fabrication by lithography and multilevel processing usually require a number of processing steps with lithographic resolution and alignment adequate for the scale of the device be fabricated. As an alternative, the focused ion beam (FIB) microscope is increasingly being used directly to fabricate devices. A major advantage of using a FIB compared to other lithography methods is its flexibility and high resolution. It allows in-situ, milling (#propor to#5 nm at a beam current of 1 pA) to a variety of depths, and imaging (2 nm) of the sample. In this paper we describe our development of junction fabrication techniques using the FIB and their application in creating a range of potential sensor devices and quantum electronics applications. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2005-03-01

305

Effects of wildfires on environmental variability: a comparative analysis using different spectral indices, patch metrics and thematic resolutions  

British Library Electronic Table of Contents (United Kingdom)

Knowledge on environmental variability and how it is affected by disturbances is crucial for understanding patterns of biodiversity and determining adequate conservation strategies. The aim of this study is to assess environmental variability in patches undergoing post-fire vegetation recovery, identifying trends of change and their relevant drivers. We particularly evaluate: the value of three spectral indices derived from Landsat satellite data [Normalized Burn Ratio (NBR), Normalized Difference Vegetation Index (NDVI) and Wetness Component of the Tasseled Cap Transformation (TCW)] for describing secondary succession; the effectiveness of three metrics (diversity, evenness and richness) as indicators of patch variability; and how thematic resolution can affect the perception of environme...

2010-01-01

306

Discrimination of Korean ginseng (Panax ginseng) roots using rapid resolution LC-QTOF/MS combined by multivariate statistical analysis  

British Library Electronic Table of Contents (United Kingdom)

Korean ginseng (Panax ginseng C.A. Meyer) contains several types of saponins and ginsenosides, which are usually considered the major active components of ginseng. The types and quantities of saponins found in ginseng may differ depending on the region of cultivation. As a result, ginsengs produced in different areas of Korea have been unintentionally mislabeled and/or confused by Korean herbal markets owing to their complicated plant sources. Another concern is that 4- and 6-year-old ginseng roots, traditionally prescribed for different medicinal purposes, can vary in total saponin contents. Therefore, it is necessary to establish a reliable method for distinguishing different cultivation regions and ages of ginseng roots. A rapid resolution liquid chromatography-quadruple time of flight ...

2011-01-01

307

Creation of nitrogen-vacancy centres in diamond with high resolution  

International Nuclear Information System (INIS)

Nowadays, diamond and the nitrogen-vacancy (NV) colour centres constitute the best solid-state system in view of quantum-computing applications. It has also been shown recently that single NV centres could be used as nanoscale magnetic sensors. Such applications require the creation of single NV centres with very high resolution and with a high efficiency. The nano-implanter at the university of Bochum provides low energy nitrogen ions which can be implanted through a hole pierced in the tip of an atomic force microscope. Ultrapure diamond samples have been implanted with spot sizes of 50nm and less. Stimulated Emission Depletion (STED) microscopy has been used to characterise and resolve the implanted spots.

2010-03-21

308

Characterization of polymer solar cells by TOF-SIMS depth profiling  

Energy Technology Data Exchange (ETDEWEB)

Solar cells consisting of polymer layers sandwiched between a transparent electrode on glass and a metal top electrode are studied using dynamic time-of-flight secondary ion mass spectrometry (TOF-SIMS) in dual-beam mode. Because depth profiling of polymers and polymer-metal stacks is a relatively new field the craters were thoroughly investigated by environmental SEM (ESEM), interferometry, surface profilometry and tapping mode AFM. A huge increase in crater bottom roughness was observed when starting from the aluminum top layer going in depth, resulting in a loss of depth resolution. It is shown that layer-to-layer diffusion and contaminants at buried interfaces can be extracted from the depth profiles when taking into account the loss of depth resolution.

2003-01-15

309

Behavior of triterpenes from Maytenus aquifolium Martius ('espinheira santa') upon X- and gamma-rays irradiation  

International Nuclear Information System (INIS)

The behavior of the triterpenes friedelin and friedelan-3-ol, contained on the leaves of Maytenus aquifolium Martius (Celastraceae), upon several doses of X- and #gamma#-rays (10 to 100 kGy), was investigated by high resolution gas chromatography (HRGC) and high resolution gas chromatography -mass spectrometry (HRGC-MS). The friedelin content has not changed with #gamma#-irradiation, but the content of friedelan-3-ol decreased around 17% at doses of 10, 20 and 40 kGy and around 27% at doses of 60, 80 and 100 kGy. The levels of both triterpenes remained unchanged even at higher X-ray doses. Lupen-3-one was detected by HRGC-MS. (author).

310

Angiography of the head using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).

1985-01-01

311

Absolute differential cross sections for electron capture and loss by kilo-electron-volt hydrogen atoms  

International Nuclear Information System (INIS)

This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H_2, N_2, O_2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02 degree--2 degree, with an angular resolution of 0.02 degree. The high angular resolution allows us to observe structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.

312

A method for determining the origin of bitumoids  

Energy Technology Data Exchange (ETDEWEB)

The invention is associated with organic geochemistry and may be used in conducting geological exploration operations for oil and gas. The purpose of the invention is to increase the precision of the method for determining the genesis of bitumoids. This is achieved through determining the isotopic composition of nickel or vanadium and from the anomalously high values of the isotopic ratio of Ni-58 to Ni-62 or from the anomalously low values of the isotopic ratio of vanadium, a conclusion is drawn about the epigenetic nature of the bitumoids. The proposed method is characterized by greater resolution due to the fact that the values of the isotopic ratios for oil bearing and water bearing structures are essentially not superimposed. The proposed method exceeds the resolution of metal metering studies in conducting geological exploration for oil and gas by 2 to 3 times.

1983-01-01

313

A fast multipole transformation for global climate calculations  

Energy Technology Data Exchange (ETDEWEB)

A fast multipole transformation is adapted to the evaluation of summations that occur in global climate calculations when transforming between spatial and spherical harmonic representations. For each summation, the timing of the fast multipole transformation scales linearly with the number of latitude gridpoints, but the timing for direct evaluations scales quadratically. In spite of a larger computational overhead, this scaling advantage renders the fast multipole method faster than direct evaluation for transformations involving greater than approximately 300 to 500 gridpoints. Convergence of the fast multipole transformation is accurate to machine precision. As the resolution in global climate calculations continues to increase, an increasingly large fraction of the computational work involves the transformation between spatial and spherical harmonic representations. The fast multipole transformation offers a significant reduction in computational time for these ...

1996-01-01

314

A Multi-Layered Image Cache for Scientific Visualization  

Energy Technology Data Exchange (ETDEWEB)

We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.

2003-06-26

315

Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge  

Energy Technology Data Exchange (ETDEWEB)

Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at different spatial scales, and the spatial relationship between primary sulfide and ...

2008-05-22

316

Transbrachial arterial digital subtraction angiography  

International Nuclear Information System (INIS)

27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).

1985-01-01

317

The production and destruction of negative ions  

Energy Technology Data Exchange (ETDEWEB)

During the present grant period we have continued our study of the photodetachment of atomic negative ions using cross-beam photoelectron detachment spectroscopy. The experimental technique involves the measurement of, under conditions of good energy and angular resolution, kinetic energies, yields and angular distributions of photoelectrons ejected from the interaction region between perpendicularly crossed laser and negative ion beams. 6 figs.

1990-01-01

318

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

319

The central tracking detectors for D/O/  

Energy Technology Data Exchange (ETDEWEB)

Three types of drift chambers are being constructed for the Fermilab D/O/ experiment. The construction and readout of these chambers stress good spatial resolution, good two hit separation, and dE/dx. A 106 MHz FADC system with hardware zero suppression is being constructed to readout this system. 8 refs., 12 figs., 1 tab.

1988-01-01

320

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. ...

1999-11-01

321

Table of Contents  

British Library Electronic Table of Contents (United Kingdom)

Abstract Clonidine Extended Release Augmentation of Psychostimulants in ADHD ADHD a Risk Factor for Substance Abuse; Cognitive Deficits Not a Predictor Commentary on Kollins et al.; Clonidine XR Augmentation for ADHD Pharmacologic Treatment of Childhood Insomnias Effects of Guanfacine Extended Release on Alertness in ADHD Long Term ADHD Drug Treatment Bipolar Disorder Rates Similar Across Selected Countries Group CBT Alone or Group CBT Plus SSRIs in Childhood Anxiety Resolution of Quetiapine-Induced Oral Dyskinesia From the FDA

2011-01-01

322

TWENTE Study: The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente: study design, rationale and objectives  

UK PubMed Central (United Kingdom)

Background. New-generation drug-eluting stents (DES) may solve several problems encountered with first-generation DES, but there is a lack of prospective head-to-head comparisons between...Full Text Available

2010-08-01

323

Study of cosmic ray nuclei detection by an image calorimeter  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a cosmic gamma-ray telescope made of a multilayer silicon tracker and a imaging CsI calorimeter, is capable of identifying cosmic ray nuclei. The telescope charge resolution is estimated around 4% independently of charge. Simulation methods are used to determine the telescope properties for nuclei detection.

1995-09-01

324

Structural relaxation and crystallization in the Fe-Cr-Si-B and Fe-Cu-Cr-Si-B amorphous alloys  

International Nuclear Information System (INIS)

Structural relaxation, crystallization and optimisation processes in soft magnetic amorphous alloys based on iron are examined by applying different experimental techniques: X-ray diffraction analysis, high-resolution electron microscopy, measurements of magnetic and electric properties (permeability, after-effect resistivity). The presented results are discussed in terms of annealing out of microvoids, formation of nanocrystalline phase and changes of effective magnetostriction constant. (author)

2001-09-23

325

Si(111)/Gd: A fast and high-resolution thermal neutron detector  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.

1998-07-01

326

Scanning tip microwave near-field microscope  

Energy Technology Data Exchange (ETDEWEB)

A near-field microscope which operates in the rf/microwave frequency range is described. In this microscope, a scanning tunneling microscope (STM)-like tip rather than an aperture is used as a point-like evanescent field emitter. A spatial resolution of {approximately}5 {mu}m ({approximately}{lambda}/100000) is achieved in the current version. The design of the microscope as well as the principal factors which affect its performance are discussed. {copyright} {ital 1996 American Institute of Physics.}

1996-06-01

327

Resolution of key safety-related issues in FFTF regulatory review  

International Nuclear Information System (INIS)

The FFTF is an ERDA facility which does not require licensing, but a technical review by NRC is required by ERDA policy. Safety issues which were not fully resolved in the course of the review for construction authorization have been the subject of continuing review since mid-1973. These issues included HCDA energetics, design fallback provisions for additional safety margins, piping integrity, and natural circulation core cooling.

328

Research in heavy-ion nuclear physics. Annual progress report, May 1, 1991--April 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.

1992-01-01

329

Real time neutron diffraction experiments using Bragg edges  

Energy Technology Data Exchange (ETDEWEB)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1995-12-31

330

Real time neutron diffraction experiments using Bragg edges  

International Nuclear Information System (INIS)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1994-12-02

331

Proposed high-resolution vertex detector using superconductive thin strips  

Energy Technology Data Exchange (ETDEWEB)

The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alpha particle.

1984-06-01

332

Proceedings of the workshop on high resolution computed microtomography (CMT)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the workshop was to determine the status of the field, to define instrumental and computational requirements, and to establish minimum specifications required by possible users. The most important message sent by implementers was the remainder that CMT is a tool. It solves a wide spectrum of scientific problems and is complementary to other microscopy techniques, with certain important advantages that the other methods do not have. High-resolution CMT can be used non-invasively and non-destructively to study a variety of hierarchical three-dimensional microstructures, which in turn control body function. X-ray computed microtomography can also be used at the frontiers of physics, in the study of granular systems, for example. With high-resolution CMT, for example, three-dimensional pore geometries and topologies of soils and rocks can be obtained readily and implemented directly in transport models. In turn, these geometries can ...

1997-02-01

333

Pharmaceutics | Special Issue: Molecular Imaging  

Wastenet

...) Abstract: Fluorescence microscopic imaging is widely used in biomedical research to study molecular and cellular processes in cell culture or tissue samples. This is motivated by the high inherent sensitivity of fluorescence techniques, the spatial resolution that compares favorably with cellular dimensions, the stability of the fluorescent labels used and the sophisticated strategies that have been developed for selectively labeling target molecules. More recently, two and ...

334

Phantom simulation device for scintillation cameras  

Energy Technology Data Exchange (ETDEWEB)

A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.

1981-08-25

335

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

336

Particle identification through the measurement of the Bragg curve centroid  

Energy Technology Data Exchange (ETDEWEB)

A new method of particle identification of heavy ions through the measurement of the Bragg curve centroid and particle energy has been developed using a gas ionization chamber with a resistive anode layer. Z-resolutions comparable to the conventional ..delta..E-E counter telescope could be rather easily attained.

1983-07-01

337

Particle identification through the measurement of the Bragg curve centroid  

International Nuclear Information System (INIS)

A new method of particle identification of heavy ions through the measurement of the Bragg curve centroid and particle energy has been developed using a gas ionization chamber with a resistive anode layer. Z-resolutions comparable to the conventional #DELTA#E-E counter telescope could be rather easily attained. (orig.).

338

Particle identification by modified Bragg-curve centroid detection  

Energy Technology Data Exchange (ETDEWEB)

A new article identification method based on the measurement of Bragg-curve centroids using a gas-filled ionization chamber has been improved for detection of low-energy particles around 1 MeV per nucleon by introducing a nonuniform distribution of resistance on the anode electrode. Almost the same quality of Z-resolutions as in the conventional ..delta..E-E method could be obtained up to Z=19.

1987-03-01

339

Ordered Cloned DNA Map of the Genome of Vibrio cholerae 569B and Localization of Genetic Markers  

UK PubMed Central (United Kingdom)

By using a low-resolution macrorestriction map as the foundation (R. Majumder et al., J. Bacteriol. 176:1105–1112, 1996), an ordered cloned DNA map of the 3.2-Mb chromosome of the hypertoxinogenic...Full Text Available

1998-02-01

340

Optimization of soft magnetic properties in Fe-B and Fe-B-Si amorphous alloys obtained by melt spinning method  

International Nuclear Information System (INIS)

In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)

2001-09-23

341

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

342

Nonlinear air-coupled emission: The signature to reveal and image microdamage in solid materials  

International Nuclear Information System (INIS)

It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.

2007-12-17

343

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...

1986-01-01

344

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were programmed on an Intellect 100 ...

1986-01-01

345

Measurement of gas flow velocities by laser-induced gratings  

Energy Technology Data Exchange (ETDEWEB)

Time resolved light scattering from laser-induced electrostrictive gratings was used for the determination of flow velocities in air at room temperature. By measuring the velocity profile across the width of a slit nozzle we demonstrated the high spatial resolution (about 200 mm) of this novel technique. (author) 3 figs., 1 ref.

1999-08-01

346

Laser photochemical etching of molybdenum and tungsten thin films by surface halogenation  

Energy Technology Data Exchange (ETDEWEB)

Laser direct-write etching of the refractory metals Mo and W was developed using reactions in chlorine and nitrogen trifluoride vapors. Rate and high spatial resolution are simultaneously optimized using a two-vapor halogenation/development sequence, based on surface modification. Local-area laser chlorination of the metal surface is used to predispose areas to subsequent bulk etching.

1986-12-01

347

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

348

Insights into finding a mismatch through the structure of a mispaired DNA bound by a rhodium intercalator  

UK PubMed Central (United Kingdom)

We report the 1.1-Å resolution crystal structure of a bulky rhodium complex bound to two different DNA sites, mismatched and matched in the oligonucleotide 5′-(dCGGAAATTCCCG)2-3′....Full Text Available

2007-01-09

349

High resolution transmission electron microscopy of a #beta#'-sialon-TiN nanocomposite  

International Nuclear Information System (INIS)

TEM and HRTEM have been used to characterise the microstructures of materials formed by hot-pressing silicon nitride with an Al_2O_3-SiO_2-TiO_2 densification aid system, to form #beta#'-sialon-TiN composites in which the TiN particles are of 20-100 nm dimension. (orig.).

1992-06-21

350

FT-IR spectroscopic studies of fulvic acid from weathered coal and its complexes  

International Nuclear Information System (INIS)

FT-IR spectrum of fulvic acid from wheathered coal of Gongxian is determined using second derivative spectroscopy and the spectroscopic resolution is enhanced. Moreover, FT-IR spectra of the complexes of fulvic acid with Ca"2"+, Ba"2"+, Cu"2"+, Pb"2"+ and UO_2"2"+ under different pH are determined and the nature of the coordination of these complexes is discussed.

1995-01-01

351

Effect of Atmospheric Conditions on LIBS Spectra  

Energy Technology Data Exchange (ETDEWEB)

Laser-induced breakdown spectroscopy (LIBS) is typically performed at ambient Earth atmospheric conditions. However, interest in LIBS in other atmospheric conditions has increased in recent years, especially for use in space exploration (e.g., Mars and Lunar) or to improve resolution for isotopic signatures. This review focuses on what has been reported about the performance of LIBS in reduced pressure environments as well as in various gases other than air.

2010-05-01

352

Early Dynamic Risk Stratification with Baseline Troponin Levels and 90-minute ST Segment Resolution to Predict 30 Day Cardiovascular Mortality in STEMI: Analysis from CLARITY TIMI-28  

UK PubMed Central (United Kingdom)

BackgroundTroponin is the preferred biomarker for risk stratification in non-ST-elevation ACS. The incremental prognostic utility of the initial magnitude of troponin...Full Text Available

2010-06-01

353

Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in ...

1984-12-01

354

D-Glyceraldehyde-3-Phosphate Dehydrogenase: Three-Dimensional Structure and Evolutionary Significance  

UK PubMed Central (United Kingdom)

A 3.0-Å resolution electron density map of lobster glyceraldehyde-3-phosphate dehydrogenase (EC 1.2.1.12) was computed. The essentially single isomorphous replacement map was very substantially...Full Text Available

1973-11-01

355

Bragg-curve spectroscopy at high rates  

Energy Technology Data Exchange (ETDEWEB)

The performance of a Bragg ionization chamber has been investigated as a function of the counting rate with approx.= 5 MeV/amu /sup 32/S beams: up to approx.= 20 kHz the energy resolution is below 0.9% and the Z resolving power is more than 50. (orig.).

1986-03-01

356

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

357

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

358

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

359

Bounding ingestion stream-tube determination via a CO tracer  

Energy Technology Data Exchange (ETDEWEB)

A gas tracer technique based on carbon monoxide and a commercial automotive exhaust gas analyser has been applied to wind tunnel models of waterjet propulsion systems intakes. The post-processing and interpretation of the carbon monoxide concentration signals has yielded high resolution measurements of the bounding ingestion stream-tubes. (orig.) With 3 figs., 1 tab., 8 refs.

1998-05-01

360

Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors  

Energy Technology Data Exchange (ETDEWEB)

A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.)

1993-10-01

361

Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors  

International Nuclear Information System (INIS)

A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.).

362

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

363

An ADP proposal to study the formation and evolution of dust-embedded clusters. Final report  

International Nuclear Information System (INIS)

Using high resolution and high sensitivity IRAS data at 12 and 25 microns low mass stars were studied which have recently formed in the Ophiuchus, Corona Australis, and IC1396 dark clouds. The successful application of these techniques to the Rho Ophiuchi infrared cluster is briefly described. The status of research performed is also presented.

364

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

365

A photon beam position monitor for SSRL beamline 9  

Energy Technology Data Exchange (ETDEWEB)

We present here the concept of a simple one dimensional photon beam position monitor for use with high power synchrotron radiation beams. It has micron resolution, reasonable linearity in an inexpensive design. Most important, is its insensitivity to diffusely scattered low energy radiation from components upstream of the monitor.

1995-10-01

366

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

367

A High-Wavenumber Viscosity for High-Resolution Numerical Methods  

Energy Technology Data Exchange (ETDEWEB)

Numerical simulations of compressible flows are commonly based on the Euler equations when effects of viscosity are thought to be negligible. These equations admit singular solutions, even in cases where the initial and boundary conditions are smooth. So-called ''Euler solvers'' rely on numerical dissipation, explicitly or implicitly present in the scheme, to regularize the problem, such that physical solutions are selected.

2003-02-19

368

A 3D tomographic EBSD analysis of a CVD diamond thin film  

Energy Technology Data Exchange (ETDEWEB)

We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

2008-09-15

369

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the ...

1998-05-01

370

ALOS satellite imagery utilizations for safeguards  

International Nuclear Information System (INIS)

This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digital images. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an inclination angle of 98.16 ...

2006-10-16

371

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of ...

372

Vibration signature analysis of AFM images  

Energy Technology Data Exchange (ETDEWEB)

Vibration signature analysis has been commonly used for the machine condition monitoring and the control of errors. However, it has been rarely employed for the analysis of the precision instruments such as an atomic force microscope (AFM). In this work, an AFM was used to collect vibration data from a sample positioning stage under different suspension and support conditions. Certain structural characteristics of the sample positioning stage show up as a result of the vibration signature analysis of the surface height images measured using an AFM. It is important to understand these vibration characteristics in order to reduce vibrational uncertainty, improve the damping and structural design, and to eliminate the imaging imperfections. The choice of method applied for vibration analysis may affect the results. Two methods, the data dependent systems (DDS) analysis and the Welch`s periodogram averaging method were investigated for application to this problem. Both techniques provide ...

1995-12-31

373

The vital importance of GIS : a workshop in project siting and development  

Energy Technology Data Exchange (ETDEWEB)

Geographic information system (GIS) technology is now being used by wind energy developers who are required to consider and accommodate a wide variety of environmental and social considerations. This poster presentation discussed some of the new features available in current GIS technologies. High resolution imagery from satellites is being used to verify the accuracy of collected spatial data, as well as to investigate potential locations for meteorological towers, turbine sites, and roads. Slopes are easily calculated using GIS software tools, and digital elevation data can be used with high resolution aerial photography to determine routes for new roads and to establish available sites for crane pads. The GIS tools allow developers to consider protected ecological areas, wetlands and forests, and gives them the ability to better report project development considerations at public consultations. Wind resource grid outputs can also be ...

2010-07-01

374

The optical emission nebulae in the vicinity of WR 48 (Theta Mus); True Wolf-Rayet ejecta or unconnected supernova remnant?  

CERN Document Server

During searches for new optical Galactic supernova remnants (SNRs) in the high resolution, high sensitivity Anglo-Australian Observatory/United Kingdom Schmidt Telescope (AAO/UKST) HAlpha survey of the southern Galactic plane, we uncovered a variety of filamentary and more diffuse, extensive nebular structures in the vicinity of Wolf-Rayet (WR) star 48 (Theta Muscae), only some of which were previously recognised. We used the double-beam spectrograph of the Mount Stromlo and Siding Spring Observatory (MSSSO) 2.3-m to obtain low and mid resolution spectra of selected new filaments and structures in this region. Despite spectral similarities between the optical spectra of WR star shells and SNRs, a careful assessment of the new spectral and morphological evidence from our deep HAlpha imagery suggests that the putative shell of Theta Mus is not a WR shell at all, as has been commonly accepted, but is rather part of a more complex area of ...

2009-01-01

375

The design and performance of a capacitance sensor for two-phase flow concentration measurements in a square duct  

Energy Technology Data Exchange (ETDEWEB)

The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated ...

1995-12-31

376

Tensor polarization of the residual nucleus in the "6Li (#alpha#, #alpha#') "6Li (2.18 MeV, 3"+) reaction at E_#alpha# = 27.2 MeV  

International Nuclear Information System (INIS)

The experiment on the determination of the tensor polarization of the residual nucleus is described for the reaction "6Li (#alpha#, #alpha#') "6Li. It is based on the unique connection of polarization tensors t_l_m of the residual nucleus for the reaction (#alpha#, #alpha#') and the angular correlation function W (#omega#_1, #omega#_2) for #alpha#'-particle and decay product of this nucleus, where #omega#_1, #omega#_2 are motion directions of #alpha#'-particle and decay product. The angular correlations of #alpha#'-particle and deuteron are measured for the "6Li (#alpha#, #alpha#', d)"4He reaction on the 27.2 MeV #alpha#-particle beam. The recording system consists of six silicon detectors and provides the energy resolution about 0.8 MeV and the angular resolution #+-# 3 deg. The polarization tensors of the residual nucleus "6Li (2.185 MeV, 3"+) are determined as the result of measuring the angular correlations of products of the "6Li (#alpha#, ...

1999-01-01

377

Study on the stability of the Maytenus aquifolium Martius chemical components submitted to ionizing radiation (X-ray and #gamma#)  

International Nuclear Information System (INIS)

The interest for medicinal plants has raised again in the last decades, after overcoming a declination period caused by the advances in the researches and development of the synthetic drugs industries. This growing interest has been stimulated mainly by searching cheap and accessible alternative therapies. However, in order to have natural products based treatment in an efficient and safety way, it is necessary to guarantee the plant authenticity, finding adulterations and to assure a low level of microbiological contaminations to avoid damages to consumer's health. The decontamination method should be chosen for eliminating or reduce the microorganisms level without loss of the plant active constituents that would destroy its therapeutic action. At the present work, the possibility of using #gamma# and X electromagnetic radiations to sterilize a Brazilian medicinal plant (Maytenus aquifolium Martius, Celastraceae), which shows anti-ulcer activity, was studied by accomplishing its ...

378

Structure of Mg$_n$ and Mg$_n^+$ clusters up to n=30  

CERN Document Server

We present structure calculations of neutral and singly ionized Mg clusters of up to 30 atoms, as well as Na clusters of up to 10 atoms. The calculations have been performed using density functional theory (DFT) within the local (spin-)density approximation, ion cores are described by pseudopotentials. We have utilized a new algorithm for solving the Kohn-Sham equations that is formulated entirely in coordinate space and, thus, permits straightforward control of the spatial resolution. Our numerical method is particularly suitable for modern parallel computer architectures; we have thus been able to combine an unrestricted simulated annealing procedure with electronic structure calculations of high spatial resolution, corresponding to a plane-wave cutoff of 954eV for Mg. We report the geometric structures of the resulting ground-state configurations and a few low-lying isomers. The energetics and HOMO-LUMO gaps of the ground-state ...

2011-01-01

379

Rotation seismic sensor and its calibration; Kaiten seibun jishinkei no shisaku to kando no kentei  

Energy Technology Data Exchange (ETDEWEB)

Sensor has been developed for the measurement of seismic wave rotary components. The vertical axis rotary component sensor is constituted of four L22Ds, similar to each other in performance, fixed in a ring formation on a metal bed. The ring is 22cm in diameter, and the four coils are connected so that their outputs will be added up. A horizontal axis rotary component sensor is built in the similar way. The rotary component sensors are all connected to a spectrum analyzer for the measurement of micromotions. It is found that the four-L22D combination can detect a rotary component of 335mV/deg/s. The sensor can detect both vertical and horizontal components with roughly the same sensitivity. A ring-form combination of conventional electromagnetic seismometers, though only as a temporary expedient, can perform high-resolution detection of rotary components and determine the absolute values of earthquakes or noise levels. In the case of a gyrosensor available on the ...

1997-05-27

380

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in signal-to-noise ratio. The latter can be increased further with the technique of weighted averaging in Fourier-space. A comparison of 2D and 3D ...

2003-01-01

381

Remote sensing monitoring method of hyperspectral and high-resolution for underground coal bed combustion  

Energy Technology Data Exchange (ETDEWEB)

Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface temperature retrieval model was built. Finally, by hyperspectral imagery ...

2007-10-15

382

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these imaging detectors in ...

2001-01-01

383

Real time neutron reflectometry using neutron optical imaging  

International Nuclear Information System (INIS)

We will describe recent improvements to the SPEAR reflectometer at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos. One of the changes consists of wider convergent, incident-beam, collimation to take advantage of optical imaging for specular scattering. In addition, the instrument now views a partially coupled liquid hydrogen moderator as opposed to the decoupled moderator that was previous in-place. While the wavelength distribution is poorer, it matches the time (wavelength) resolution of the reflectometer more closely with the angular resolution. Since the integrated intensity of the partially coupled moderator is higher than the decoupled moderator, we show a similar gain in incident beam flux on the sample without loss of the ability to separate fringes. The increases in intensity from the moderator gain and the improved collimation combine to allow us to measure reflectivities with good statistics down to 10"-"4 in a matter ...

2001-03-01

384

Real time neutron reflectometry using neutron optical imaging  

Energy Technology Data Exchange (ETDEWEB)

We will describe recent improvements to the SPEAR reflectometer at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos. One of the changes consists of wider convergent, incident-beam, collimation to take advantage of optical imaging for specular scattering. In addition, the instrument now views a partially coupled liquid hydrogen moderator as opposed to the decoupled moderator that was previous in-place. While the wavelength distribution is poorer, it matches the time (wavelength) resolution of the reflectometer more closely with the angular resolution. Since the integrated intensity of the partially coupled moderator is higher than the decoupled moderator, we show a similar gain in incident beam flux on the sample without loss of the ability to separate fringes. The increases in intensity from the moderator gain and the improved collimation combine to allow us to measure reflectivities with good statistics down to 10{sup -4} in a ...

2001-03-01

385

Performance characterization of a volumetric breast ultrasound scanner  

Science.gov (United States)

The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue ...

2007-03-01

386

Numerical modeling of slug flow initiation in a horizontal channels using a two-fluid model  

International Nuclear Information System (INIS)

This paper presents a methodology for modeling slug initiation and growth in horizontal ducts. Transient two-fluid equations are solved numerically using a class of high-resolution shock capturing methods. The advantage of this method is that slug formation and growth in a stratified regime can be calculated directly from the solutions to the flow field differential equations. In addition, by using high-resolution shock capturing methods that do not contain numerical diffusion, the discontinuity generated by slugging in the flow field can be modeled with good accuracy. The two-fluid model is shown to be well-posed mathematically only under certain conditions. Under these circumstances, the two-fluid model is capable of correctly predicting and modeling the flow physics. When ill-posed, an unbounded instability occurs in the flow field solution, and the instability amplitude increases exponentially with decreasing mesh sizes. This work shows ...

2011-02-01

387

Multi-wavelength observations of the young binary system Haro 6-10: The case of misaligned discs  

CERN Document Server

Context. We present a multi-wavelength, high-resolution observational survey of the young binary system Haro 6-10 (GV Tau, IRAS 04263+2426), which is harbouring one of the few known infrared companions. Aims. The primary goal of this project is to determine the physical and geometrical properties of the circumstellar and circumbinary material in the Haro 6-10 system. Methods. High-resolution optical (HST/WFPC2) and near-infrared (VLT/NACO) images in different bands were analysed to investigate the large-scale structures of the material around the binary.Mid-infrared interferometry (VLTI/MIDI) and spectroscopy (TIMMI2 at the 3.6m ESO telescope) were carried out to determine the structure and optical depth of the circumstellar material around the individual components. Results. The multi-wavelength observations suggest that both components of the binary system Haro 6-10 are embedded in a common envelope. The measured extinction indicates a dust ...

2011-01-01

388

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast images are extracted from experimental projection images by an algorithm similar to ...

2006-08-01

389

Magnetic resonance imaging of the hip with a pelvic phased-array surface coil: a technical note  

Energy Technology Data Exchange (ETDEWEB)

Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer phased-array surface coils ...

1998-02-01

390

MR imaging of experimental intramuscular hemorrhage at 0. 02 T; Contrast enhancement with Gd-DOTA  

Energy Technology Data Exchange (ETDEWEB)

Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).

1990-09-01

391

In-situ focused ion beam (FIB) microscopy at high temperature  

International Nuclear Information System (INIS)

Materials Scientists need information on the kinetics of the microstructural evolution processes that determine the finished microstructure, and hence the properties, of any material. E.g. recrystallisation, grain growth and phase changes. Such kinetic information requires reliable discrimination of differently oriented crystallites and/or different crystal phases coupled with useful spatial resolution and temporal resolution (i.e. high frame rates). These imaging results must be realised from a hot and changing specimen, in an instrument that is compatible with that hot specimen and with a practical specimen heater. Focused Ion Beams (FIB) offer strong contrast between crystallites and phases, and hence offer the ability to discriminate between these features even while imaging at fast frame rates, however their compatibility with hot specimens was unproven. Here we report results from a novel combination of FIB with an in-situ heating stage, ...

2008-08-01

392

Imaging properties of the Medipix2 system exploiting single and dual energy thresholds  

CERN Document Server

Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in photon counting mode with a single threshold ...

2006-01-01

393

High-resolution stratigraphy in a Miocene reservoir of the Niger delta  

Energy Technology Data Exchange (ETDEWEB)

High-resolution sequence stratigraphy concepts are applied to Erema, a Miocene onshore field of the Niger delta. The field's production is decreasing and an up-to-date geological model is essential to monitor the production. We aim to show an approach, using subsurface data and sequence stratigraphic concepts, which results in a time-line (Maximum Flooding Surfaces) correlation scheme. This scheme is based upon a facies model and is destined to guide the study of the characterization of reservoir heterogeneities. Using the cored well as a reference point, the facies model consists of shoreface dunes (planar tabular cross-stratified sandstones) changing landward into fluvial distributary deposits (through cross-stratified sandstones) via a tide-influenced coastal plain facies. The stacking pattern of genetic units shows a seaward stepping phase at the reservoir scale (sixty metres thick) with an abrupt deepening at the top of the reservoir. The proposed ...

1994-06-30

394

High-resolution sequence stratigraphy of a Hettangian-Sinemurian parallic succession, Bornholm, Denmark  

Energy Technology Data Exchange (ETDEWEB)

Sequence stratigraphic interpretation of paralic successions is complicated by the complex interfingering of marine and continental strata. The successions may also include terrestrial extensions of marine parasequences and completely independent lacustrine parasequence analogues. Failure in recognizing the possible interbedding of these two independent parasequence types may lead to construction of sequence stratigraphic schemes based on incompatible data sets. We have studied a Lower Jurassic paralic section from the Baltic island of Bornholm. The Hettangian-Sinemurian Sose Bugt Member (Ronne Formation) of Bornholm includes lacustrine, fluvial and restricted marine, estuarine deposits reflecting the basin-margin position. Biostatigraphic resolution is poor and a sequence stratigraphic interpretation of the paralic succession is far from straightforward. A multidisciplinary approach including facies analysis, recognition and lateral tracting of key surface, ...

1995-04-01

395

High resolution spectroscopy of second overtone transitions in solid parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

The high resolution spectrum of the parahydrogen Q{sub 3}(0) transition at 11758 cm{sup -1} has allowed specific quantum state assignment of the ten lines which compose this transition. The transition cannot occur unless a dipole moment is induced in the parahydrogen by an external field. The quadrupole field of an impurity o-H{sub 2} molecule provides this field, and the transition occurs in the orientationally dependent field of the orthohydrogen molecule. Transitions induced by the quadrupolar field of the J=1 H{sub 2} in the nearest neighbor as well as in the next nearest neighbor shells have been observed. By lowering the impurity orthohydrogen concentration, the authors have observed lines with linewidths of approximately 15 MHz hwhm with a Ti:Sapphire laser having a sensitivity of 3x10{sup -5} ({Delta}I/I) using the toneburst method. Additionally, the second vibrational overtone of the impurity orthohydrogen molecule (Q{sub 3}(1)) has been observed at ...

1995-12-31

396

High resolution sequence stratigraphy, sedimentology, petrology and reservoir potentials of the Glauconitic member in Westerose and adjacent fields, Alberta, Canada  

Energy Technology Data Exchange (ETDEWEB)

This thesis studied the petrology and sequence stratigraphy of the Hoadley barrier, a Glauconitic member in the Westerose field in Alberta. The unit contains gas reserves in an extensive northeast-southwest trending marine complex. A high resolution sequence stratigraphic model was used to understand the facies development of the unit and the diagenetic pathway of the strata. Six high frequency sequences were identified within the Glauconitic member. Each are separated from one another by surfaces of incision or subaerial exposure which sometimes coincide with a flooding surface and erosion. This thesis provided a petrographic characterization and depositional history of each of the 6 sequences. Reservoir quality is developed within the relatively quartz-rich foreshore facies of the G2B sandstones. The G3 chert litharenite to sublitharenite sandstones are excellent gas producers because of their coarser grain size and secondary porosity. The G4, G5 and G6 are ...

2002-07-01

397

High resolution scanning electron microscopy of plasmodesmata.  

Science.gov (United States)

Symplastic transport occurs between neighbouring plant cells through functionally and structurally dynamic channels called plasmodesmata (PD). Relatively little is known about the composition of PD or the mechanisms that facilitate molecular transport into neighbouring cells. While transmission electron microscopy (TEM) provides 2-dimensional information about the structural components of PD, 3-dimensional information is difficult to extract from ultrathin sections. This study has exploited high-resolution scanning electron microscopy (HRSEM) to reveal the 3-dimensional morphology of PD in the cell walls of algae, ferns and higher plants. Varied patterns of PD were observed in the walls, ranging from uniformly distributed individual PD to discrete clusters. Occasionally the thick walls of the giant alga Chara were fractured, revealing the surface morphology of PD within. External structures such as spokes, spirals and mesh were observed surrounding the PD. ...

2011-05-28

398

High resolution electron microscopy and computer simulation studies of the atomic structure of tilt boundaries in TiO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The atomic structure of [001] tilt grain boundaries of {Sigma}5 (210), {Sigma}5 (310), {Sigma}13 (320) and {Sigma}17 (410) in TiO{sub 2}(rutile) were studied using high resolution electron microscopy and computer simulation. Regularly separated small steps (1/2 [120] high) and big steps (3/2 [120] high) which contain secondary dislocations were found in the (210) boundary as a result of deviation from the exact {Sigma}5 misorientation and (210) symmetric plane. Similar steps were also found in (310) and (320) boundaries. Flat segments between the steps were found to have very accurate misorientation of the {sigma}`s and a nearly symmetric boundary plane. Their rigid body translation, volume expansion and relaxed structures were determined by comparing HRTEM images with computer calculated structures and simulated images. An irregular core structure was found in the (410) boundary when its misorientation deviated 2{degree} from the exact {Sigma}17 misorientation.

1995-09-01

399

High resolution Fourier transform spectroscopy and crystal-field analysis in Tm,Ho:BaY{sub 2}F{sub 8}  

Energy Technology Data Exchange (ETDEWEB)

A Tm{sup 3+}- Ho{sup 3+} -codoped single crystal of monoclinic BaY{sub 2}F{sub 8} has been characterized by means of high resolution FTIR spectroscopy in the wave number range 2000-24000 cm{sup -1} and in the temperature range 9-300 K. The energy level schemes of the two lanthanide ions as determined by the optical absorption spectra is presented, analyzed, and fitted within a single ion Hamiltonian model. The very small energy separation (about 0.6-1.6 cm{sup -1}) measured between the first and second sublevels of the ground state manifolds for both the ions is in line with the theoretical predictions. The impurity-phonon coupling is put into evidence by the thermally induced line shift and broadening, and by the detection of vibronic replicas of a few lines. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2005-01-01

400

High resolution Fourier transform spectroscopy and crystal-field analysis in Tm,Ho:BaY_2F_8  

International Nuclear Information System (INIS)

A Tm"3"+- Ho"3"+ -codoped single crystal of monoclinic BaY_2F_8 has been characterized by means of high resolution FTIR spectroscopy in the wave number range 2000-24000 cm"-"1 and in the temperature range 9-300 K. The energy level schemes of the two lanthanide ions as determined by the optical absorption spectra is presented, analyzed, and fitted within a single ion Hamiltonian model. The very small energy separation (about 0.6-1.6 cm"-"1) measured between the first and second sublevels of the ground state manifolds for both the ions is in line with the theoretical predictions. The impurity-phonon coupling is put into evidence by the thermally induced line shift and broadening, and by the detection of vibronic replicas of a few lines. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2005-01-01

401

High Spatial Resolution Optical and Radio Imagery of the Circumbinary Environment  

CERN Document Server

In this review, I concentrate on describing observations of spatially resolved emission in symbiotic stars at sub-arcsecond scales. In some of the closer objects, the highest resolutions discussed here correspond to linear dimensions similar to the supposed binary separation. A total of 17 stars well accepted as symbiotics are now observed to show sub-arcsecond structure, almost twice the number at the time of the last review in 1987. Furthermore, we now have access to HST imagery to add to radio interferometry. From such observations we can derive fundamental parameters of the central systems, investigate the variation of physical parameters across the resolved nebulae and probe the physical mechanisms of mass loss and interactions between ejecta and the circumstellar medium. Suggestions for future work are made and the potential of new facilities in both the radio and optical domains is described. This review complements that by Corradi (this volume) which mainly ...

2004-01-01

402

Gravitational waves interferometer and the VIRGO project  

CERN Document Server

Radio, optical and X-rays telescopes are improving our knowledge of deep space. All these telescopes detect electromagnetic radiation at various frequencies. But a different kind of radiation is generated in the deeper space; it is the gravitational one. Gravitational waves change the space-time metric. As a consequence, GW telescopes should detect an extremely small strain (h < 10/sup -21/) of the geometry of a reference frame; if the frame has a reference dimension (L) of some kilometers, the deformation amplitude ( Delta L = h * L) is limited to 10/sup -16/ meters. Laser interferometers are the most suitable devices to make precise measurements of distances. Their resolution is limited by the laser wavelength ( lambda = 10/sup -6/ meters) and by the light wave-shift detection capability ( Delta Phi = 1 ppb). These theoretical limits are strongly degraded by different noise sources, which reduce the actual resolution by several orders of ...

2002-01-01

403

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences  

International Nuclear Information System (INIS)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an ...

404

Four small puzzles that Rosetta doesn't solve  

CERN Document Server

A complete macromolecule modeling package must be able to solve the simplest structure prediction problems. Despite recent successes in high resolution structure modeling and design, the Rosetta software suite fares poorly on deceptively small protein and RNA puzzles, some as small as four residues. To illustrate these problems, this manuscript presents extensive Rosetta results for four well-defined test cases: the 20-residue mini-protein Trp cage, an even smaller disulfide-stabilized conotoxin, the reactive loop of a serine protease inhibitor, and a UUCG RNA tetraloop. In contrast to previous Rosetta studies, several lines of evidence indicate that conformational sampling is not the major bottleneck in modeling these small systems. Instead, approximations and omissions in the Rosetta all-atom energy function currently preclude discriminating experimentally observed conformations from de novo models at atomic resolution. These molecular ...

2011-01-01

405

Fluid pressure arrival time tomography: Estimation and assessment in the presence of inequality constraints, with an application to a producing gas field at Krechba, Algeria  

Energy Technology Data Exchange (ETDEWEB)

Deformation in the overburden proves useful in deducing spatial and temporal changes in the volume of a producing reservoir. Based upon these changes we estimate diffusive travel times associated with the transient flow due to production, and then, as the solution of a linear inverse problem, the effective permeability of the reservoir. An advantage an approach based upon travel times, as opposed to one based upon the amplitude of surface deformation, is that it is much less sensitive to the exact geomechanical properties of the reservoir and overburden. Inequalities constrain the inversion, under the assumption that the fluid production only results in pore volume decreases within the reservoir. We apply the formulation to satellite-based estimates of deformation in the material overlying a thin gas production zone at the Krechba field in Algeria. The peak displacement after three years of gas production is approximately 0.5 cm, overlying the eastern margin of the anticlinal structure ...

2010-04-01

406

Fabrication and characterization of low aberration micrometer-sized electron lenses.  

Science.gov (United States)

Intrinsic spherical aberrations of electron lenses have been the major resolution limiting factor in electron microscopes for several decades. While effective correctors have recently been implemented, an alternative to correct these aberrations is to circumvent them by scaling down lens dimensions by several orders of magnitude. We have fabricated electrostatic lenses exhibiting one micrometer diameter apertures and evaluated their beam forming properties against predictions from numerical ray tracing simulations. It turns out that it is routinely possible to shape a paraxial low-energy electron beam by such micron-sized lenses. Beam profiles have been measured both at a distant detector as well as in a plane close to the lens. It is shown that the lens can form a parallel beam extending no more than 800 nm from the optical axes at a distance of 200 microm beyond the lens exit. We believe that these findings constitute a prerequisite to derive novel tools for high ...

2010-04-24

407

Effect of alcohols and temperature on the direct chiral resolutions of fipronil, isocarbophos and carfentrazone-ethyl.  

Science.gov (United States)

The enantiomeric separations of three pesticides fipronil (asymmetric nitrogen), isocarbophos (asymmetric phosphorus) and carfentrazone-ethyl (asymmetric carbon) were studied on cellulose-tri(3,5-dimethylphenylcarbamate) chiral stationary phase using high-performance liquid chromatography under normal phase. The mobile phase was n-hexane with alcohols including ethanol, n-propanol, iso-propanol, n-butanol and iso-butanol as polar modifiers. The flow rate was 1.0 mL/min with UV detection at 280, 225 and 230 nm for fipronil, isocarbophos and carfentrazone-ethyl respectively. The influence of the modifiers and their volume content and temperature from 0 to 50 degrees C on the separations was investigated. The chiral stationary phase showed excellent stereoselectivity for the two enantiomers of fipronil and isocarbophos and certain chiral recognition for carfentrazone-ethyl. Iso-propanol was more suitable for the chiral separation of isocarbophos and carfentrazone-ethyl, and iso-butanol ...

2005-07-01

408

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the response of the complete detector formed by an ...

409

Depth profiling using C{sub 60} {sup +} SIMS-Deposition and topography development during bombardment of silicon  

Energy Technology Data Exchange (ETDEWEB)

A C{sub 60} {sup +} primary ion source has been coupled to an ion microscope secondary ion mass spectrometry (SIMS) instrument to examine sputtering of silicon with an emphasis on possible application of C{sub 60} {sup +} depth profiling for high depth resolution SIMS analysis of silicon semiconductor materials. Unexpectedly, C{sub 60} {sup +} SIMS depth profiling of silicon was found to be complicated by the deposition of an amorphous carbon layer which buries the silicon substrate. Sputtering of the silicon was observed only at the highest accessible beam energies (14.5 keV impact) or by using oxygen backfilling. C{sub 60} {sup +} SIMS depth profiling of As delta-doped test samples at 14.5 keV demonstrated a substantial (factor of 5) degradation in depth resolution compared to Cs{sup +} SIMS depth profiling. This degradation is thought to result from the formation of an unusual platelet-like grain structure on the SIMS crater bottoms. Other ...

2006-07-30

410

Cosmological Hydrodynamics with Adaptive Mesh Refinement a new high resolution code called RAMSES  

CERN Document Server

A new N-body and hydrodynamical code, called RAMSES, is presented. It has been designed to study structure formation in the universe with high spatial resolution. The code is based on Adaptive Mesh Refinement (AMR) technique, with a tree based data structure allowing recursive grid refinements on a cell-by-cell basis. The N-body solver is very similar to the one developed for the ART code (Kravtsov et al. 97), with minor differences in the exact implementation. The hydrodynamical solver is based on a second-order Godunov method, a modern shock-capturing scheme known to compute accurately the thermal history of the fluid component. The accuracy of the code is carefully estimated using various test cases, from pure gas dynamical tests to cosmological ones. The specific refinement strategy used in cosmological simulations is described, and potential spurious effects associated to shock waves propagation in the resulting AMR grid are discussed and found to be ...

2001-01-01

411

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, ...

2005-10-23

412

Cold SQUIDs and hot samples  

Energy Technology Data Exchange (ETDEWEB)

Low transition temperature (low-{Tc}) and high-{Tc} Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-{Tc} superconductors using two low-{Tc} SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise sources, suggesting that the vortices moved as rigid rods. At other temperatures, the ...

1997-05-01

413

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 cases of subtle ...

1991-11-01

414

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 cases of subtle ...

1991-01-01

415

Bulk-sensitive high-resolution photoemission study of a temperature-induced valence transition system EuPd{sub 2}Si{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Eu 4f electronic structures of a temperature-induced valence transition system EuPd{sub 2}Si{sub 2} have been investigated by bulk-sensitive high-resolution photoemission spectroscopy at temperatures from 20 to 300 K. The bulk Eu{sup 2+} 4f component is definitely distinguished from two surface Eu{sup 2+} 4f components. The changes in the spectral intensity of the bulk Eu{sup 2+} and Eu{sup 3+} 4f configurations and in the energy separation between these states are observed in the temperature dependent photoemission spectra. These temperature dependences are related to the valence transition of EuPd{sub 2}Si{sub 2}. The Eu mean valence is evaluated to be 2.75{+-}0.03 at 20 K and 2.30{+-}0.05 at 300 K. These values are in good agreement with those evaluated from Moessbauer and Eu L{sub III}-edge X-ray absorption measurements.

2004-07-01

416

Atomic beam spectrometer using a LiF analyzer crystal  

International Nuclear Information System (INIS)

An energy analyzer has been constructed and operated in UHV for the purpose of analyzing the energy of neutral atoms scattered from solid surfaces. The analyzer consists of a LiF single crystal located at an angle close to the normal to the sample crystal so that the diffraction pattern obtained by scanning the LiF crystal yields the energy of the scattered atoms. Two designs which have been used are described. The temperature of both sample and analyzer crystal is near 20 K and once cleaned they can be maintained in the state of initial preparation for many weeks. The sample was a (001) Cu surface in this case. Such an energy analyzer can only be used, in most cases, for He atom scattering although Ne atoms could be used if the scattered intensities were adequate. The detector developed in this study is able to detect about 2 x 10"5 atoms/s. The resolution of the spectrometer depends on the incident energy of the atom and is about 1 meV at an incident energy of 23 ...

1978-01-01

417

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, ...

2004-03-21

418

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes ...

2004-03-21

419

Analysis of active site distribution in ZSM-5 crystals by infrared microscopy  

Science.gov (United States)

The acid site distribution over large ZSM-5 crystals was analyzed using FTIR microscopy. Results of the analysis of the OH-stretching vibrations and of vibrations of pyridine adsorbed on Bronsted and Lewis acid sites were found to be in good agreement. The resolution which can be obtained using this novel technique is about 10-20 [mu]m. This limits the application to large crystals as analyzed in this study. Comparison of the results of IR microscopy with aluminum distributions obtained by electron microprobe analysis revealed that IR microscopy cannot resolve inhomogeneities on a scale smaller than the above-state limits. The results of both methods on a larger scale, however, are in very good agreement. Using a combination of both techniques, it is possible to obtain a clearer picture of the distribution of acid sites in large zeolite crystals, where electron microprobing gives the higher resolution, and IR microscopy allows the determination ...

1993-10-01

420

Aerodynamic force measurement on a large-scale model in a short duration test facility  

International Nuclear Information System (INIS)

A force measurement technique has been developed for large-scale aerodynamic models with a short test time. The technique is based on direct acceleration measurements, with miniature accelerometers mounted on a test model suspended by wires. Measuring acceleration at two different locations, the technique can eliminate oscillations from natural vibration of the model. The technique was used for drag force measurements on a 3 m long supersonic combustor model in the HIEST free-piston driven shock tunnel. A time resolution of 350 #mu#s is guaranteed during measurements, whose resolution is enough for ms order test time in HIEST. To evaluate measurement reliability and accuracy, measured values were compared with results from a three-dimensional Navier-Stokes numerical simulation. The difference between measured values and numerical simulation values was less than 5%. We conclude that this measurement technique is sufficiently reliable for ...

2005-03-01

421

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...

2000-03-21

422

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic advantages for MRT. ...

423

4D experience on Girassol Field block 17, Angola  

Energy Technology Data Exchange (ETDEWEB)

The Girassol field is located in Angolan deep water of Block 17 and consists of large vertically stacked turbidities complexes. The reservoir extends over approximately 200 km{sup 2} and water depth ranges between 1300 and 1400 meters. In that context High Resolution 3D seismic became the most valuable tool to describe and monitor the reservoir. The field development plan took into account, through re-injection of the gas into the reservoir, Total environmental policy imposing the recycling of production gas. Monitoring of this injection was the main reason to shoot the first High Resolution 4D extremely early in the life of field. Despite the complexity of interpretation due to complex fluid situation and pressure effect, the results went way beyond expectations as the 4D images are of very high quality. Data has also been used to update and refine the reservoir flow model as well as to help deciding on the location of latest development ...

2004-07-01

424

"Mtrack 2.0": An ultra-scale tracking algorithm for low-resolution overhead imagery  

Energy Technology Data Exchange (ETDEWEB)

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery is very desirable. Typically, this imagery has many thousands of pixels on a side and is characterized by lower resolutions (e.g. {approx}0.5 meters/pixel to {approx}2.0 meters/pixel) and lower frame rates (e.g. {approx} sub-Hz to several Hz). We describe our ultra-scale capable implementation of a multiple-vehicle tracking algorithm for overhead persistent surveillance imagery. This work builds upon an earlier report, where now the algorithm has been modified for improved performance and has been substantially improved to handle much larger datasets in a much shorter time.

2008-09-26

425

The use of a mesoscale numerical model for evaluations of pollutant transport and diffusion in coastal regions and over irregular terrain  

Energy Technology Data Exchange (ETDEWEB)

A modelling approach is presented that appears to have the potential to provide reliable assessments of pollution concentration in coastal zones and complex terrain, where the assumptions behind current operational air quality models often are inadequate. With the use of a numerical mesoscale model (NMM), physically consistent flow fields can be predicted, thereby providing higher spatial and temporal resolution in the meteorological fields than would be available from a limited number of observation points. These predictions are used to calculate mean trajectories of pollutant parcels, as well as to provide quantitative estimates of pollution concentration using two techniques.

1983-03-01

426

The nanoworld through aberration corrected lenses  

International Nuclear Information System (INIS)

The advent of aberration correction for electron microscope lenses has produced a significant advance in the improvement of resolution in microscopy. This improvement, while significant in itself, promises to have its most profound impact in materials science when it delivers quantitative information to challenge models and modellers. This capability for an electron microscope-modelling synergy to deliver useful results at the atomic level is not yet firmly established. For this reason, one of the major challenges for electron microscopy in materials science over this decade is to study systems where electron microscopists and modellers can work collaboratively. This paper explores some examples.

2010-07-01

427

The Polish Nuclear Society on the energy situation in Poland  

Energy Technology Data Exchange (ETDEWEB)

Discusses the resolution of the 2. Congress of the Polish Nuclear Society on the energy situation in Poland and recommendations for energy policy. Recommendations for use of nuclear power plants in Poland are made considering environmental pollution from coal combustion (air pollution by sulfur dioxide, nitrogen oxides and carbon dioxide as well as water pollution by salt from mine water discharged to rivers), development of the Polish economy, forecast increase in energy consumption and the role of nuclear energy in other European countries. Research on nuclear power plants, safety and environmental aspects as well as comparative efficiency of coal-fired power plants and nuclear power plants is evaluated.

1993-10-01

428

The AMS-02 electromagnetic calorimeter  

CERN Document Server

The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).

2002-01-01

429

Study of radiation chemistry in solids using solid hydrogen  

Energy Technology Data Exchange (ETDEWEB)

Having simple and highly symmetric structure, solid hydrogen is a useful matrix on the study of radiation-chemical processes in solid phase which have been less understood in previous studies. We have found three outstanding findings: resonance effects on the tunneling reaction H+H{sub 2} {yields} H{sub 2} + H, effects of pressure on the dissociation and recombination of H{sub 2} molecules in solid hydrogen, and high-resolution ESR spectroscopy using a solid parahydrogen matrix. (author)

2002-03-01

430

State analysis of sulfur in coal and coal fly ash by double-crystal X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Double-crystal high-resolution x-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and position are different. The chemical state of sulfur in coal and remaining in fly ash is discussed.

1983-01-01

431

Species dependence of the emittances of sputter-generated negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum analysed /sup 28/Si/sup -/, /sup 58/Ni/sup -/ and /sup 197/Au/sup -/ ion beams generated by caesium ion sputtering. The high-resolution emittance measurement techniques employed in this work have enabled us to estimate the energy spreads of these ion beams; differences in the widths of the energy distributions are the origin of the observed differences in emittances of the ion beams investigated. (author).

1989-04-14

432

Smart Acquisition EELS  

Energy Technology Data Exchange (ETDEWEB)

Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.

2010-07-01

433

Singularities and Closed String Tachyons  

Energy Technology Data Exchange (ETDEWEB)

A basic problem in gravitational physics is the resolution of spacetime singularities where general relativity breaks down. The simplest such singularities are conical singularities arising from orbifold identifications of flat space, and the most challenging are spacelike singularities inside black holes (and in cosmology). Topology changing processes also require evolution through classically singular spacetimes. I briefly review how a phase of closed string tachyon condensate replaces, and helps to resolve, basic singularities of each of these types. Finally I discuss some interesting features of singularities arising in the small volume limit of compact negatively curved spaces and the emerging zoology of spacelike singularities.

2006-03-17

434

Shot-noise-limited measurement of sub-parts-per-trillion birefringence phase shift in a high-finesse cavity  

International Nuclear Information System (INIS)

We report on a promising approach to high-sensitivity anisotropy measurements using a high-finesse cavity locked by optical feedback to a diode laser. We provide a simple and effective way to decouple the weak anisotropy of interest from the inherent mirror's birefringence whose drift may be identified as the key limiting parameter in cavity-based techniques. We demonstrate a shot-noise-limited phase shift resolution previously inaccessible in an optical cavity, readily achieving the state-of-the-art level of 3x10"-"1"3 rad.

2010-09-01

435

Short term relative sea-level oscillations in Upper Devonian Nisku Formation (Alberta, Canada): application to hydrocarbon exploration and recent discoveries  

Energy Technology Data Exchange (ETDEWEB)

The relationship between short term relative sea-level oscillations and the reef, off-reef deposits geometry of an Upper Devonian third order sequence highstand of the Nisku Formation in west central Alberta was studied through the analysis of high resolution sequence stratigraphy. Hydrocarbon generation was reconstructed by total organic carbon values and migration patterns that were dependent on the geometry of three fourth order sequences. This stratigraphic reconstruction provided the key to recent hydrocarbon discoveries such as in the Brazeau southern reef margin.

1997-09-01

436

Selective enhancement of barium in the atmospheres of red giants  

Energy Technology Data Exchange (ETDEWEB)

High-resolution spectroscopy of 13 bright red giants and Ba stars shows selective enhancement of Ba in three of them, HD 65699 (Ba 2), ..cap alpha..TrA (K4 III), and epsilonPeg (K2 Ib). Infrared spectra available for HD 65699 show that Sr is enhanced, too. This selective enhancement is discussed in terms of a modified s-process which converts some of the pre-existing r- and s-process matter into the magic nuclei /sup 88/Sr and /sup 138/Ba.

1984-03-01

437

SNAP sky background at the north ecliptic pole  

Energy Technology Data Exchange (ETDEWEB)

I summarize the extant direct and indirect data on the sky background SNAP will see at the North Ecliptic Pole over the wavelength range 0.4 < {lambda} < 1.7 {micro}m. At the spatial resolution of SNAP the sky background due to stars and galaxies is resolved, so the only source considered is zodiacal light. Several models are explored to provide interpolation in wavelength between the broadband data from HST and COBE observations. I believe the input data are now established well enough that the accuracy of the sky background presented here is sufficient for SNAP simulations, and that it will stand up to scrutiny by reviewers.

2002-07-01

438

Reversible Movement of Homogenously Nucleated Dislocations in a #beta#-Titanium Alloy  

International Nuclear Information System (INIS)

We demonstrate reversible movement of (1/2)[110](110) dislocation loops generated from nanodisturbances in a #beta#-titanium alloy. High resolution transmission electron microscope observations during an in situ tensile test found three reversible deformation mechanisms, nanodisturbances, dislocation loops and martensitic transformation, that are triggered in turn with increasing applied stress. All three mechanisms contribute to the nonlinear elasticity of the alloy. The experiments also revealed the evolution of the dislocation loops to disclination dipoles that cause severe local lattice rotations.

2009-01-30

439

Results from the photoemission spectroscopy beamline 2B1 at Pohang Light Source  

Energy Technology Data Exchange (ETDEWEB)

The results of photoemission spectroscopy using molybdenum and tantalum samples have been obtained from the new beamline 2B1 at Pohang Light Source. Beamline 2B1 is based on a spherical grating monochromator (SGM) which is equipped with five gratings. The photon energy range from 184 to 1100 eV was covered in this work using two gratings (Gratings 4 and 5). The photon energy resolution has been deduced from Ta Fermi-level spectra and 3d spectra of Mo.

1999-06-01

440

Recent observations of Cassiopeia A  

International Nuclear Information System (INIS)

During the last few years radio and X-ray astronomers have produced high-resolution imagery of the remnant of Cas A. Since the most recent published optical photographs of Cas A date back to 1975 it seemed worthwhile to present new optical results based on plates obtained with the 5-m Hale telescope in 1976, 1977, and 1980. The major changes that have taken place in Cas A during the last decade are: (1) A broken shell of fast-moving knots has formed along the southern and SW rim of the remnant and (2) A number of blue (oxygen-rich) filaments have developed to the north of the centre of Cas A. (Auth.).

441

Randomization of heavily damaged regions in annealed low energy Ge{sup +}-implanted (0 0 1)Si  

Energy Technology Data Exchange (ETDEWEB)

Apparent growth of amorphous layers during low temperature annealing was observed in low energy Ge{sup +}-implanted (0 0 1)Si by high-resolution transmission electron microscopy. The occurrence of abnormal growth is due to the randomization of heavily damaged regions beneath the original amorphous/crystalline interfaces. The randomization process is attributed to the strain, incurred by the presence of a high density of large Ge atoms in the heavily damaged Si substrate, relaxation to lower the free energy of the systems. The randomization upon annealing may be fruitfully applied to minimize the transient enhanced diffusion in shallow junction formation.

2004-01-15

442

Randomization of heavily damaged regions in annealed low energy Ge"+-implanted (0 0 1)Si  

International Nuclear Information System (INIS)

Apparent growth of amorphous layers during low temperature annealing was observed in low energy Ge"+-implanted (0 0 1)Si by high-resolution transmission electron microscopy. The occurrence of abnormal growth is due to the randomization of heavily damaged regions beneath the original amorphous/crystalline interfaces. The randomization process is attributed to the strain, incurred by the presence of a high density of large Ge atoms in the heavily damaged Si substrate, relaxation to lower the free energy of the systems. The randomization upon annealing may be fruitfully applied to minimize the transient enhanced diffusion in shallow junction formation.

2004-01-01

443

Radiation damage measurements in room temperature semiconductor radiation detectors  

Energy Technology Data Exchange (ETDEWEB)

The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and increases in FWHM ...

1998-12-01

444

Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study  

British Library Electronic Table of Contents (United Kingdom)

There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.

2011-01-01

445

Preliminary Design of ARIES-Devasthal Faint Object Spectrograph and Camera  

CERN Document Server

We present here the preliminary design of ARIES-Devasthal Faint Object Spectrograph and Camera (ADFOSC), which is a multi-mode instrument for both imaging and spectroscopy. ADFOSC is the first-generation instrument to be mounted at the axial port of the Cassegrain focus on our new 3.6m optical telescope to be installed at Devasthal, Nainital. The main design goals of the instrument are : the instrument will have capability of broad- and narrow-band imaging, low-medium resolution spectroscopy, and imaging polarimetry. The operating wavelength range will be from 360 to 1000 nm and the instrument will have remote-control capability.

2009-01-01

446

Observation of stochastic resonance near a subcritical bifurcation  

Energy Technology Data Exchange (ETDEWEB)

A hysteretic subcritical period-doubling bifurcation is observed in the nonlinear strain dynamics of a magnetostrictive oscillator. The dynamic strain response of the magnetostrictive oscillator was observed with a high-resolution fiber optic interferometer. The effects of low-frequency modulation and band-limited stochastic fluctuations on such a bifurcation are investigated. Power spectral density measurements show that for an optimal value of externally injected noise the signal-to-noise ratio of a low-frequency modulation signal is enhanced by greater than 14 dB, thus indicating the first experimental observation of stochastic resonance near a bistable period-doubling bifurcation. 10 refs., 7 figs.

1993-01-01

447

New techniques for electron-ion collision studies  

International Nuclear Information System (INIS)

We have constructed an apparatus to study electron impact ionization of ions which should provide additional insight into the mechanisms involved. Using multiparameter coincidence techniques, we will detect both outgoing electrons from ionization process and will be able to analyze the momenta of both particles simultaneously. Coupled with a high resolution electron gun, this information should have broad application to the difficult problem of three bodies interacting via the long range Coulomb force. If sufficient accuracy can be achieved, information regarding the relative phase of the outgoing electron wavefunctions can be obtained.

448

New radioisotope for lung ventilation studies: 19-neon  

Energy Technology Data Exchange (ETDEWEB)

Neon 19, a 17-second positron-emitting radioelement, is produced continously by 23 MeV alpha particle bombardment of oxygen. For a 12 ..mu..A particle current the method of preparation described delivers 14 mCi of neon 19 per min to the functional exploration room. The radiochemically pure radioactive gas is diluted in air and breathed continously by the patient lying under a positron tomographic camera. The regional lung ventilation distribution is obtained on 2 cm thick sections of organ with a transverse resolution of 17 mm. Quantification of the ventilation output per unit lung volume is contemplated.

1980-10-01

449

Nanostructure of Si-Ge near-surface layers produced by ion implantation and laser annealing  

International Nuclear Information System (INIS)

An annealing with the nanosecond laser light pulse is applied for crystal lattice reconstruction of a disturbed near-surface layer, which was created in semiconductor material as a result of the implantation process. Radiation with energy density higher than the threshold value causes the melting of the surface layer and than the epitaxial recrystallization from the melt on a different substrate. Structural changes occurring in the Ge implanted Si crystals after annealing with different energy densities are investigated by means of the cross-section high-resolution transmission electron microscopy. (author)

2001-09-23

450

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image ...

2008-07-01

451

Method of determining migrational bitumoids  

Energy Technology Data Exchange (ETDEWEB)

This invention refers to the organic geochemistry and can be used in prospecting for oil and gas. The method includes taking samples of rocks, extracting from them the chloroform bitumoid and its thermal processing. In order to improve the accuracy, the equal quantities of bitumoid taken are exposed to gradual thermal treatment to temperatures exceeding the thresholds of thermal stability of sulfur-containing compounds, in each temperature interval, the content of hydrogen sulfide released in this case is revealed, and by its drastic increase at temperatures corresponding to the temperatures of the productive part of the section, a conclusion is drawn about the epigenetic nature of the bitumoid. The method makes it possible to improve the resolution of the bituminological prospecting for oil and gas.

1982-01-01

452

Measurements of "8"8Sr(p,n) to the ground state and low-lying excited states of "8"8Y  

International Nuclear Information System (INIS)

The (p,n) cross section on "8"8Sr was measured for proton energies between 5.75 and 11 MeV. Overall resolution was sufficient to separate the "8"8Y ground state (J/sup #pi#/ = 4"-), the first excited state (J/sup #pi#/ = 5"-) at 0.232 MeV, and the second excited state (J/sup #pi#/ = 1"+) at 0.393 MeV. A Legendre polynomial fit was made to the angular distributions and the resulting integrated cross sections are shown. 1 figure.

1980-03-13

453

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

454

MTF analysis of the near-real time neutron radiography facility at MURR  

International Nuclear Information System (INIS)

Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).

1981-12-01

455

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

456

Large-scale absolute dent evaluation campaign  

International Nuclear Information System (INIS)

Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).

457

K_#beta#/K_#alpha# X-ray intensity ratio following K-electron capture and radioisotope excitation  

International Nuclear Information System (INIS)

The K_#beta#/K_#alpha# X-ray intensity ratios are measured for Mn and Fe and for six other elements with Z lying in the range 49<=Z<=82 following electron capture decay and photon excitation using "2"4"1Am and "5"7Co sources. High-resolution Si(Li) and HpGe detector systems were used in the experiments. The dependence of K_#beta#/K_#alpha# values on the mode of excitation in the case of Mn and Fe is attribuited to the chemical effects, while no such dependence is found for the high-Z elements.

1987-01-01

458

Imaging characterization of carbon nanotube tips modified using a focused ion beam  

International Nuclear Information System (INIS)

A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.

2007-06-15

459

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

460

Grain boundary dissociation by the emission of stacking faults  

Energy Technology Data Exchange (ETDEWEB)

A range of <110> symmetric tilt grain boundaries (GBs) are investigated in several fcc metals with simulations and high resolution electron microscopy. Boundaries with tilt angles between 50.5{degree} and 109.5{degree} dissociate into two boundaries 0.6 to 1.1 nm apart. The dissociation takes place by the emission of stacking faults from one boundary that are terminated by Shockley partials at a second boundary. This is a general mode of GB relaxation for low stacking fault energy metals. The reasons for the occurrence of this relaxation mode are discussed using the theory of GB dislocations.

1995-05-01

461

Florida State University - Explores! World Headquarters  

Science.gov (United States)

EXPLORES! (EXPloring and Learning the Operations and Resources of Environmental Satellites!) is an educational outreach program developed at Florida State University with the intention of introducing weather satellite receiving technology into the primary and secondary school classrooms. The website furnishes real time high resolution imagery and tropical updates. Visitors can find historical accounts of the civilian weather satellites launched by the United States. Educators can discover kindergarten through twelfth grade resources and curriculum. Users can learn how to become a part of the WXSAT-L community email list where weather satellite professionals, amateurs, and hobbyists converse about scientific, tracking, launching, and operations information.

462

Esterification of chiral secondary alcohols with fatty acid in organic solvents by polyethylene glycol-modified lipase.  

Science.gov (United States)

Lipase from Pseudomonas fragi 22.39B was modified with polyethylene glycol. The modified lipase (PEG-lipase) was soluble and active in organic solvents such as benzene and 1,1,1-trichloroethane. PEG-lipase catalyzed esterification of chiral secondary alcohols with fatty acids in benzene and exhibited preference for R isomers over S isomers. Km and Vmax values for each isomer of various alcohols were obtained by kinetic study of the esterification in benzene. PEG-lipase-catalyzed esterification leads to optical resolution of a racemic alcohol. PMID:2635854

1989-11-01

463

Energy planning in developing countries: the role of microcomputers  

Energy Technology Data Exchange (ETDEWEB)

Microcomputers are beginning to be used for energy analysis in many developing countries, and have the potential for making a significant contribution to the resolution of difficult analytical and data problems, and to improving communications between analyst and decision maker. Successful introduction of a microcomputer based on analytical capability, however, requires attention to several important factors in order to avoid the mistakes of the earlier mainframe computer era. This paper reviews the key issues of matching models to staff capabilities, of training, and of the operating environment, based on the author's first-hand experience with microcomputer projects in Uruguay, Haiti and Sri Lanka. 3 figures, 3 tables.

1985-02-01

464

Electron impact ionization of C_6_0 and C_7_0 and decay of the singly and multiply charged (up to z=7) ions produced  

International Nuclear Information System (INIS)

Mass spectrometry was instrumental in the discovery of the fullerenes and the characterization of their special structure (truncated icosahedron). High resolution and high sensitivity mass spectrometry in combination with a crossed molecular beam/electron beam ion source is used here to study a further, very unique property of singly and multiply charged fullerene ions (up to Z=7), i.e. their strong resilience towards decomposition via sequential C_2 evaporation and via Coulomb explosion, respectively. (author).

1994-03-20

465

Dispersion Interferometer Based on CO2 Laser  

International Nuclear Information System (INIS)

A dispersion interferometer based on CO2 laser for measurements of plasma line density in the gas dynamic trap (GDT) experiment has been developed with sensitivity el>min ? 1.1013 cm-2, temporal resolution ?50 ns. The main advantages of the interferometer are compactness and low sensitivity to vibrations. The interferometer does not require specific vibration isolation structure and can be mounted directly on the working chamber of the plasma device. The above mentioned advantages have been successfully demonstrated in the Gas Dynamic Trap experiments.

2005-01-01

466

Development of time-resolved laser fluorescence spectrometry for on-line uranium checking in solutions of the Purex reprocessing process; Developpement de la spectrofluorimetrie laser a resolution temporelle pour le controle en ligne de l`uranium dans les solutions du procede de retraitement purex  

Energy Technology Data Exchange (ETDEWEB)

The Purex process and the fluorescence spectrometry are first recalled, then uranyl fluorescence is studied in a pure nitric medium without other elements to establish a theoretical model, allowing the description of uranium fluorescence signal with a general equation. The influence of different parameters (temperature, inhibitors, dynamic quenching of iron and cerium) is investigated to develop the model. A quantitative analysis method without addition of reagents is proposed to validate the model.

1992-02-25

467

Development of superconducting cryo-electron microscope and its applications  

International Nuclear Information System (INIS)

Recently, a superconducting cryo-electron microscope in which specimens are cooled to the liquid helium temperature (4.2 K) has been developed. The main components and functional features of this new microscope are reported together with application data on polyethylene, poly (4-methyl-1-pentene), valonia cellulose, rock salt, ice crystallites and ceramic superconductor. The resistance to electron radiation damage, of beam-sensitive specimens including polymers has been increased more than ten times. Thus, the microscope has made it possible to take high resolution images and to analyze the crystal-structure of micro-areas. (orig.).

1988-01-01

468

Cores of early-type galaxies - the nature of dwarf spheroidal galaxies  

International Nuclear Information System (INIS)

The characteristics and evolution of dwarf spheroidal galaxies (DSGs) are modeled on the basis of high-resolution CCD photometry obtained with the Canada-France-Hawaii telescope and reported by Kormendy (1986). The data and the results of core-parameter correlation studies are presented in extensive graphs and discussed. It is inferred that at least some DSGs are formed by the stripping of gas from dwarf spiral and irregular galaxies, although internal gas processes may also be important. The hypothesis that DSGs represent the faint end of the elliptical-galaxy sequence appears to be ruled out. 50 references.

469

Common envelope evolution  

British Library Electronic Table of Contents (United Kingdom)

The common envelope phase of binary star evolution plays a central role in many evolutionary pathways leading to the formation of compact objects in short period systems. Using three dimensional hydrodynamical computations, we review the major features of this evolutionary phase, focusing on the conditions that lead to the successful ejection of the envelope and, hence, survival of the system as a post common envelope binary. Future hydrodynamical calculations at high spatial resolution are required to delineate the regime in parameter space for which systems survive as compact binary systems from those for which the two components of the system merge into a single rapidly rotating star. Recent algorithmic developments will facilitate the attainment of this goal.

2010-01-01

470

Cerebral angiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).

1985-01-01

471

Breast imaging with a dedicated PEM  

International Nuclear Information System (INIS)

During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.

2004-07-11

472

Application of proportional counters in Polish medicine and agriculture  

Energy Technology Data Exchange (ETDEWEB)

In the laboratory of Elementary Particle Physics and Detectors at the Faculty of Physics and Nuclear Techniques of the University of Mining and Metallurgy, research works on the development of proportional counters for the detection of X- and soft {gamma}-rays and {alpha}, {beta} particles have been carried out As a result of optimization of counters characteristic parameters such as: energy resolution, life time, count rate effect and temperature effect the operating stability has been reached and the elaborated detectors have been applied not only in research laboratories, but also in Polish industry, medicine and agriculture. Examples of above mentioned applications have been presented in the paper. (author). 7 refs, 7 figs, 1 tab.

1996-12-31

473

Application of a novel high resolution mass spectrometric imaging technique to elucidate nitrogen and carbon nutrition of orchids.  

Environmental Research Database

DescriptionOrchids belong to the family Orchidaceae which, with around 20,000 species, is the largest in the Plant Kingdom. Orchids hold a particular fascination because of their spectacular flowers and the rarity of many species- which has increased in recent years as a result of plant collecting, intensification of agriculture and land use changes have placed many species in jeopardy. One feature of orchids that distinguishes them from many other plants is that their seeds are so reduced in size that th [continued...

2006-01-30

474

Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels  

International Nuclear Information System (INIS)

Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes with a homogeneous phantom, and assume ...

2005-02-21

475

A hierarchical lattice structure and formation mechanism of ZnO nano-tetrapods  

International Nuclear Information System (INIS)

The existence of characteristic longitudinal optical and transverse optical phonons of cubic ZnO in ZnO nano-tetrapods is determined by Raman spectroscopy and first-principles calculations. Stacking sequence change at the boundary of the core and legs is also identified by high-resolution transmission electron microscopy. Based on this experimental and theoretical evidence, we demonstrate that the lattice structure of ZnO nano-tetrapods is hierarchical with a zinc blende core connecting to four wurtzite legs. Furthermore, we establish the atomic configuration and propose a formation mechanism induced by Laplace pressure in the initial growth stage of ZnO nano-tetrapods.

2009-08-12

476

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

477

"4"8Ca(d,n)"4"9Sc reaction at 79 MeV  

International Nuclear Information System (INIS)

We measured differential cross sections and vector analyzing powers for the "4"8Ca(d,n)"4"9Sc reaction at 79 MeV. An overall energy resolution of about 325 keV was achieved, and data were extracted for states up to 3.4 MeV of excitation. Both distorted-wave Born approximation and Johnson-Soper adiabatic approximation calculations were performed; in general, the Johnson-Soper adiabatic approximation calculations provide a better description of the data, and yield reasonable spectroscopic factors.

478

Structure, morphology and hydrogen storage properties of composites prepared by ball milling Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub 0.3}V{sub 0.3} with La-Mg-based alloy  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen storage alloy composites La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5}(x=0,5,10) were prepared by ball milling method. Their structures, morphologies and the hydrogen storage characteristics were intensively studied in the present work. It was found that the bulk of composites maintained the hexagonal C14 Laves phase structure after ball milling with additional La-Mg-based alloy for two hours. Scanning electron microscopy (SEM) observations revealed that the average size of Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub 0.3}V{sub 0.3} and La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5} particles were reduced to several hundred nanometers after ball milling process. Energy dispersive X-ray spectrometer (EDS) patterns of the composites showed that the La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5} phase was uniformly distributed on the surface of Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub ...

2007-10-15

479

Use of SPOT satellite imagery to obtain GIS input for oil spill models  

Energy Technology Data Exchange (ETDEWEB)

Satellite imagery is a cost-effective tool for creating and updating basemaps of coastal zones, especially where existing maps and aerial photographs are unavailable, are out-of-date, or provide limited information. Reliable maps of coastal zones are particularly important for oil spill modelling programs. Color IR (multispectral) images with 20m x 20m ground resolution and black & white (panchromatic) images with 10m x 10m ground resolution of many coastlines around the globe have been acquired from 1986 to present by SPOT Image Corporation. We have digitally merged same-day SPOT panchromatic and multispectral imagery to provide maximum spatial resolution and permit excellent color differentiation of coastal zone features. This combination adequately discriminates individual features, including pipelines, offshore platforms, storage tanks, jetties, and shoreline type. The SPOT images were interpreted within a ...

1995-04-01

480

Understanding the distribution and architecture of algal mound reservoirs through outcrop-based high-resolution sequence stratigraphy: An example from the paradox basin, USA  

Energy Technology Data Exchange (ETDEWEB)

An outcrop-based study combining detailed lithofacies analysis with high-resolution sequence stratigraphy in the Paradox Basin, southwestern United States. has shown that complex lateral and vertical facies variations occur in relatively consistent and predictable patterns. Large-scale facies shifts of several kilometers occur across major sequence boundaries whereas small-scale lateral and vertical variations develop from stacking of individual cycles. Understanding of vertical stacking patterns and lateral distribution of facies in outcrop can be directly applied to both three-dimensional distribution of reservoir facies in the subsurface as well as the evaluation of heterogeneity within individual reservoirs. The Desert Creek and Ismay intervals of the Paradox Formation (Pennsylvanian) exposed along the San Juan River in southeastern Utah are characterized by high-frequency cyclic repetition of carbonate and siliciclastic facies controlled primarily by 4th and ...

1995-08-01

481

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the non-destructive evaluation (NDE) of ...

2001-07-01

482

High-resolution "1H magnetic resonance spectroscopy imaging at 1.5 and 3 Tesla of the human brain: development of techniques and applications for patients with primary brain tumors and multiple sclerosis  

International Nuclear Information System (INIS)

The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings ...

483

High-Resolution Computed Tomography with Single-Slice Computed Tomography and 16-Channel Multidetector Computed Tomography: A Comparison Regarding Visibility and Motion Artifacts  

International Nuclear Information System (INIS)

Background: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. Purpose: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). Images from four anatomical levels were analyzed in ...

2007-11-01

484

High resolution seismic refraction method with multichannel digital data acquisition system; Digital ta channel sokutei system wo mochiita koseido kussetsuho jishin tansa  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces a multichannel digital data acquisition system and examples of measurements with the system in seismic exploration using the high resolution seismic refraction method. The high resolution seismic refraction system performs analyses nearly automatically by using a computer after initial travel time has been read. Therefore, the system requires high-accuracy travel time data, for which a multichannel digital measuring instrument developed recently for seismic exploration using the refraction method has been used for the measurement. The specification specifies the number of channels at 144 as a maximum, a sampling time of 62.5 {mu}sec to 4 m sec, the maximum number of sampling of 80,000 samples, and gain accuracy of {plus_minus} 1%. The system was used for surveying a tunnel having a maximum soil cover of about 800 m. The traverse line length is about 6 km, the distance between vibration receiving points is 50 m, and the ...

1997-05-27

485

High resolution electron microscopy of interfaces in fcc materials  

Energy Technology Data Exchange (ETDEWEB)

Modern high-resolution electron microscopy (HREM) instruments, which are capable of a point-to-point resolution of better than 0.2 nm, have allowed atomic-scale observations of a variety of internal interfaces. The application of the HREM technique to fcc model systems for the purpose of addressing a number of interface issues will be examined in this paper. Atomic structure observations for heterophase interfaces of metal/metal and metal/metal-oxide systems as well as HREM studies of grain boundaries in NiO and Au will be discussed with emphasis on generic structural features and the role of the interface plane. Comparisons between observed interface structures and atomistic computer modeling results have shown agreements for some interfaces, as well as certain differences in others. A number of structural features are common to both metal and oxide grain boundaries, as well as certain heterophase boundaries. Of particular importance in ...

1990-08-01

486

Failure analysis and defect review using extended accuracy of the CrossBeam {sup registered} Technology  

Energy Technology Data Exchange (ETDEWEB)

The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum system is needed. This type of instrument combines ...

2005-07-01

487

Experiments in High-Frequency Imaging of the 2004 M6.0 Parkfield Earthquake  

Science.gov (United States)

We attempt to image the rupture propagation of the 2004 M6.0 Parkfield earthquake by analyzing records from the USGS Parkfield seismic array (UPSAR) and other strong-motion stations. The UPSAR array consists of 12 stations distributed over about one square kilometer at a distance of 10~km from the San Andreas fault near Parkfield, California. We employ a method that uses reverse time migration to stack the seismograms at back-projected locations along the fault. We use waveform cross-correlation to align the initial P-wave arrivals and correct for small static time shifts in the records. This forces a coherent image at the hypocenter at the quake origin time. Initial results at later time steps show some evidence of the expected rupture propagation to the north. However, the resolution of the back-projection is limited by the small aperture of the UPSAR array. Records from other strong-motion stations can improve the theoretical resolution ...

2006-12-01

488

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-06-01

489

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-01-01

490

Experimental Study of Hypernuclei Electroproduction by High Precision Spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the analysis of CH{sub 2}, {sup 12}C and {sup ...

2009-12-01

491

Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy  

International Nuclear Information System (INIS)

High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 ...

2008-11-21

492

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, dynamic range and ...

1985-01-01

493

Considerations for the next Compton telescope mission  

International Nuclear Information System (INIS)

A high resolution Compton telescope has been identified by the Gamma Ray Astronomy Program Working Group (GRAPWG) as the highest priority major mission in gamma ray astrophysics following GLAST. This mission should provide 25-100 times improved sensitivity, relative to CGRO and INTEGRAL, for MeV gamma ray lines. It must have good performance for narrow and broad lines and for discrete and diffuse emissions. Several instrumental approaches are being pursued to achieve these goals. We discuss issues relating to this mission including alternative detector concepts, instrumental configurations, and background reduction techniques. We have pursued the development of position-sensitive solid-state detectors (Ge, Si) for a high spectral resolution Compton telescope mission. A #approx#1 m2 germanium Compton telescope of position-sensitive germanium detectors was the basis for one of the GRAPWG concepts. Preliminary Monte Carlo estimates for the ...

2000-04-12

494

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The process is observed to ...

1988-11-01

495

"Eztrack": A single-vehicle deterministic tracking algorithm  

Energy Technology Data Exchange (ETDEWEB)

A variety of surveillance operations require the ability to track vehicles over a long period of time using sequences of images taken from a camera mounted on an airborne or similar platform. In order to be able to see and track a vehicle for any length of time, either a persistent surveillance imager is needed that can image wide fields of view over a long time-span or a highly maneuverable smaller field-of-view imager is needed that can follow the vehicle of interest. The algorithm described here was designed for the persistence surveillance case. In turns out that most vehicle tracking algorithms described in the literature[1,2,3,4] are designed for higher frame rates (> 5 FPS) and relatively short ground sampling distances (GSD) and resolutions ({approx} few cm to a couple tens of cm). But for our datasets, we are restricted to lower resolutions and GSD's ({ge}0.5 m) and limited frame-rates ({le}2.0 Hz). As a consequence, we ...

2007-12-20