WorldWideScience
1

Preparation of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is fabrication and characterization of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS). The silver metal electrodes under the electrical discharge will melt and evaporate rapidly and condense to form the nanoparticles in the lower temperature dielectric liquid and produce the suspended nanoparticle. The results showed that the spherical nanosilver particle formed in the ethylene glycol and the mean particle size is about 12.5 nm. The prepared silver nanofluid was irradiated under the 410 nm visible light, electrons could be excited from the valence band to the conduction band. The silver nanofluid more closely resembles Newtonian fluids.

2007-05-31

2

Heat Transfer Enhancement of Nanofluid in Natural Convection of an Enclosure Heated from Below  

Energy Technology Data Exchange (ETDEWEB)

The general strategy for improving the safety of nuclear power plant and its economics is to accomplish power uprates while securing sufficient thermalhydraulic margin. In order to succeed this strategy, there have been a lot of efforts in increasing the margin through the enhancement of heat transfer capability in coolants. However, despite their efforts, only about 10 {approx} 15 % increase of the thermal margin is possible by using the best art known well up to now with installation of mechanical engineering devices such as mixing vane or button to generating the swirl flow and turbulent mixing. The limit of the capability of the best technique has made a lot of engineers to be frustrated to do the power uprates. Nevertheless, fortunately a new innovative idea is being proposed in heat transfer community as an engineering colloidal fluid to basically change the original properties of the coolant. The fluid began to be called by Choi as a nanofluid which is a ...

2005-07-01

3

Wolsung-1 NPP - electrictal systems  

International Nuclear Information System (INIS)

... power reactors pressure tube reactors reactors THERMAL REACTORS.

1980-06-18

4

Description of the ER-2 Dropwindsonde System The ... - ESPO - NASA  

Science.gov (United States)

2 illustrates the design of the launch tube, the gun barrel design of the multi-tube dispenser and integrated hardware pressure cannister. ...

5

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

6

Large-scale absolute dent evaluation campaign  

International Nuclear Information System (INIS)

Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).

7

Fabrication of single nanofluidic channels in poly(methylmethacrylate) films via focused-ion beam milling for use as molecular gates  

International Nuclear Information System (INIS)

Focused-ion beam (FIB) milling provides rapid fabrication of individual cylindrical submicrometer channels with reproducible dimensions (#+-#5% diameters) through 8-#mu#m thick poly(methylmethacrylate) (PMMA) films. PMMA films are spincast on sacrificial Si carriers and sputter-coated with Au before the 30-kV gallium FIB milling process. By adding a trace amount of poly(ethyleneoxide) and poly(dimethylsiloxane) to the PMMA solution before casting, the films can be released for subsequent mounting in microfluidic devices to create hybrid microfluidic-nanofluidic multilevel architectures. In situ FIB sectioning demonstrates the smooth cylindrical surface within the pore. Placing a milled film in contact with an aqueous fluorescein solution fills the channel by capillary action, as verified by confocal fluorescence microscopy. Confocal fluorescence of dyed films reveals that the pores span the thickness of the PMMA film. Small arrays of channels with a defined number ...

2004-08-16

8

Analysis of a bayonet tube heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)

2001-01-01

9

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

10

Multiple neural tube defects in the same patient with no neurological deficit  

UK PubMed Central (United Kingdom)

Congenital deformities involving the coverings of the nervous system are called neural tube defects (NTDs). NTD can be classified as neurulation defects, which occur by stage 12, and postneurulation...Full Text Available

2010-01-01

11

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the ...

12

Alloy 800 welding experience at UKAEA Springfields  

International Nuclear Information System (INIS)

Investigatins into the welding of alloy 800 at the Reactor Fuel Element Laboratories, Springfields, commenced about three years ago following an extended development programme on tube to tube plate welding of low alloy and stainless steels for the Prototype Fast Reactor. The techniques and approach developed for critical fuel element welding applications had proved equally suitable for the precision welding requirements on the much heavier sections of heat exchangers. It had been demonstrated that the same control of weld quality and profile could be achieved with consistency and the permissible range of critical parameters could be readily defined. Because of this, development work was continued to include other materials, such as alloy 800, which might be of potential use. The tungsten inert gas (T.I.G.) arc welding process is used, and the equipment, including the control system, is described. Tube ...

13

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

14

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

15

Pipe crawlers  

International Nuclear Information System (INIS)

The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).

1984-11-29

16

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks ...

1976-03-09

17

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to ...

2002-03-01

18

Burner systems  

Energy Technology Data Exchange (ETDEWEB)

A burner system particularly useful for downhole deployment includes a tubular combustion chamber unit housed within a tubular coolant jacket assembly. The combustion chamber unit includes a monolithic tube of refractory material whose inner surface defines the combustion zone. A metal reinforcing sleeve surrounds and extends the length of the refractory tube. The inner surface of the coolant jacket assembly and outer surface of the combustion chamber unit are dimensioned so that those surfaces are close to one another in standby condition so that the combustion chamber unit has limited freedom to expand with that expansion being stabilized by the coolant jacket assembly so that compression forces in the refractory tube do not exceed about one-half the safe compressive stress of the material; and the materials of the combustion chamber unit are selected to establish thermal gradient parameters across ...

1984-07-10

19

A study on the regulatory approach of KNGR multiple failure events  

Energy Technology Data Exchange (ETDEWEB)

This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in ...

2001-01-15

20

Characteristics of U-tube assembly design for CANDU 6 type steam generators  

Energy Technology Data Exchange (ETDEWEB)

Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant ...

1996-06-01

21

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

22

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

23

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

24

Bounding ingestion stream-tube determination via a CO tracer  

Energy Technology Data Exchange (ETDEWEB)

A gas tracer technique based on carbon monoxide and a commercial automotive exhaust gas analyser has been applied to wind tunnel models of waterjet propulsion systems intakes. The post-processing and interpretation of the carbon monoxide concentration signals has yielded high resolution measurements of the bounding ingestion stream-tubes. (orig.) With 3 figs., 1 tab., 8 refs.

1998-05-01

25

Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory  

International Nuclear Information System (INIS)

To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.

26

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather than a vertical one. (Author)

1994-10-01

27

Prevention of pitting corrosion on copper tubes in central hot water supply systems by UV photochemical decomposition of residual chlorine  

Energy Technology Data Exchange (ETDEWEB)

After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the same time completely ...

1988-03-25

28

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be ...

1998-11-15

29

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA ...

1999-07-15

30

User's manual for the BNW-I optimization code for dry-cooled power plants. [MFCIRI Code  

Science.gov (United States)

This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)

1977-01-01

31

Study of nuclear materials by neutron scattering.  

Science.gov (United States)

Following studies on fiber and sheet texture of hexagonal crystal system in 1988, work has been extended to tube texture. Using the zircaloy-4 fuel cladding of Wolsung-type reactor as specimen, six pole figures for different crystallographic planes were m...

1990-01-01

32

Solid-Phase Radioimmunoassay of Total and Influenza-Specific Immunoglobulin G  

UK PubMed Central (United Kingdom)

An antigen-antibody system of polystyrene tubes coated with immunoglobulin antibody was used for quantitating immunoglobulins. A similar radioimmunoassay method was adapted for a viral antigen-antibody...Full Text Available

1972-02-01

33

Comparative Inhibitory Effects of Antigen and Antibody in the Staphylococcal Enterotoxin Solid-Phase Radioimmunoassay System  

UK PubMed Central (United Kingdom)

A solid-phase radioimmunoassay employing 125I-labeled enterotoxins and polystyrene tubes coated with specific antibody has been developed for assaying the relative concentrations of antibodies...Full Text Available

1975-06-01

34

Assessment of degradation processes in corrosion resistant steels in nuclear power engineering  

International Nuclear Information System (INIS)

The possible corrosion damage is discussed of the CrNi and CrNiMo types steels used as structural materials in WWER type nuclear power plants. It includes point and slot corrosion, corrosion cracking and corrosion fatigue as well as corrosion denting. Also discussed are test procedures that simulate operating conditions and are used for assessing the properties of metallurgical products (sheets and tubes) used in nuclear power engineering. Briefly described is a system for testing the said products in an aqueous medium while keeping the test parameters in a narrow range for a long time. Under the defined temperature, pressure and corrosion medium composition, the test specimens in this system can mechanically be loaded, both statically and dynamically or a temperature gradient can be produced at the tube-tube plate joint. (Z.M.). 1 fig., 1 tab., 10 refs.

1987-12-01

35

Application of neutron radiography to a diagnosis of refrigerator  

International Nuclear Information System (INIS)

A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).

1996-07-01

36

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube ...

2003-12-01

37

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings ...

2003-12-01

38

Life extension of boilers using weld overlay protection  

Energy Technology Data Exchange (ETDEWEB)

The presentation describes the status of modern weld overlay technology for refurbishment, upgrading and life extension of boilers. The approaches to life extension of boilers include field overlay application, shop-fabricated panels for replacement of the worn, corroded waterwall and shop-fabricated overlay tubing for replacement of individual tubes in superheaters, generating banks and other areas. The characteristics of weld overlay products are briefly described. Also discussed are successful applications of various corrosion-resistant overlays for life extension of boiler tubes in waste-to-energy boilers, coal-fired boilers and chemical recovery boilers. Types of corrosion and selection of weld overlay alloys in these systems are also discussed. (orig.) 14 refs.

1998-12-31

39

Impact of Tubing Length on Hemodynamics in a Simulated Neonatal Extracorporeal Life Support Circuit  

British Library Electronic Table of Contents (United Kingdom)

Abstract During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8 Fr Biomedicus arterial and a 10 Fr Biomedicus venous cannula were connected to the pseudopatient. One fourth inch tubing was used for both the arterial and the venous line. A ...

2010-01-01

40

Heat transfer augmentation for external ice-on-tube TES systems using porous copper mesh to increase volumetric ice production  

Energy Technology Data Exchange (ETDEWEB)

Substantial thermal performance improvement in ice-on-tube cold thermal energy storage systems (TES) is possible by making use of porous copper mesh as a Heat Conducting Enhancement Device (HCED). HCEDs are inexpensive heat transfer augmentation devices that can result in faster rate of ice growth and larger final steady state ice build volume by reducing the controlling thermal conduction resistance of the ice layer. This improves the competitiveness of external ice-on-tube systems as compared to other TES systems, such as dynamic ice harvesters and static internal melt systems. In this study the amount of ice growth enhancement is predicted theoretically, by performing simplified 1-D calculations, and is then validated in the laboratory through carefully controlled experiments. This study shows that ice volume increase between 50 and 90% is possible by using ...

2006-09-15

41

Tank of sodium cooled fast reactor  

International Nuclear Information System (INIS)

Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).

42

TVA's program to mitigate steam generator denting at Sequoyah and Watts Bar Nuclear Plants  

International Nuclear Information System (INIS)

TVA is currently engaged in an extensive program to mitigate steam generator tube denting at the Sequoyah Nuclear Plant, which is in commercial operation, and to prevent or minimize the onset of denting at the Watts Bar Nuclear Plant, which is under construction. This paper describes TVA's denting mitigation program, which is primarily feedwater chemistry and system operation improvement, and the effect the changes that have been implemented have had on the incidence as well as the progression rate of steam generator tube denting during the past 220 effective full power days of Sequoyah unit 1 operation.

1983-09-25

43

Integrity assessment of pressure tubes for Wolsung unit 2  

Energy Technology Data Exchange (ETDEWEB)

To improve operational safety of the fuel channel for Wolsung units the recommended primary heat transport system (PHTS) operating guidelines were developed, which provides a safe operation window in terms of pressure and temperature to maintain fuel channel integrity, which is similar to pressure-temperature curves used for primary pressure boundary integrity in PWRs and deterministic Leak-Before Break (LBB) analyses were conducted using recent understanding of delayed hydride cracking (DHC) mechanism. In addition, a comparative assessment of LBB analysis was made using the procedures of Fitness For Service Guidelines(FFSG) for pressure tubes rev. 0 and rev. 1.

1997-10-01

44

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

45

Analysis of defect detection in steam generator tubes of FBR, under support plates and in the presence of sodium using multi-frequency eddy current algorithms  

International Nuclear Information System (INIS)

In the present paper we estimate the effect of sodium in the in-service inspection of non-magnetic steam generators tubes using eddy current technique and eddy current probes based on a differential double bobbin coil configuration. Experimental measurements of defects signals in steam generator tubes of fast breeder reactor are compared with simulations results of a two-dimensional axisymmetric finite element code to validate a reliable electromagnetic model of the system (eddy current coils, steam generator tube, defect) when there is no sodium on the outer steam generator tube surface. The electromagnetic code is used to evaluate the sodium band and sodium layer signals when a defect is located under steam generator support plate. Using a multi-frequency algorithm, its parameters are determined in the 'no sodium condition' (there is no sodium on the outer steam generator ...

2007-04-22

46

Theoretical simulation of SDS - 2 actuation in 540 MWe PHWR  

International Nuclear Information System (INIS)

The 540 MWe PHWR has two fully independent shutdown systems. The first shutdown system (SDS-1) comprises of 28 spring assisted, vertical gravity drop shut-off rods, each consisting of a cadmium absorber sandwiched between stainless steel tubes. The second shutdown system (SDS-2) constitutes six poison tanks connected to respective zircaloy injection tubes. This system is capable of high speed injection of gadolinium nitrate solution (in D2O) into the moderator through these tubes. Theoretical estimation was carried out at different injection pressures and different concentration of gadolinium nitrate solution to arrive at the limiting value of these parameters from reactivity consideration point of view. The plant measurements of SDS-2 actuations at 60 and 80 Kg/cm2 pressure of helium was used to validate and upgrade the estimation model. ...

2006-11-13

47

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

48

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube`s inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 ...

1993-05-01

49

Cross flow boiling in tube bundles  

Science.gov (United States)

This report contains two main subjects. One is the newly started investigation of cross flow boiling in tube bundles. The heat transfer information at this condition is of significant importance to horizontal steam generator design. The other one is the continuation of the research on boiling heat transfer in confined spaces. The research on cross flow boiling in tube bundles has been started. The Freon loop has been modified for higher flow and higher two phase quality. The test section design is finished and is under fabrication presently. The new instrumentation system is also established. The test matrix has been planned. The research on boiling in confined spaces proceeds steadily. This problem is of great importance to the boiling induced corrosion in the steam generator crevices between the tube and the support plate. In the report of 1981, detailed results were presented for analysis of single ...

1982-10-01

50

Visual inspection technology of the narrow and small confined area for monitoring feederpipe support of pressure tube in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post-Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And ultrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughly because of narrow and confined accessibility, that is , an inspection space between the pressure tube channels is less than 100 mm and pipes in ...

1999-12-01

51

Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests  

Energy Technology Data Exchange (ETDEWEB)

The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB ...

1998-10-01

52

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass ...

2005-03-17

53

Corrosion resistant coatings for silicon carbide heat exchanger tubes -- Volume 3. Final report  

Energy Technology Data Exchange (ETDEWEB)

The development of a silicon carbide (SiC) heat exchanger is a critical step in the development of the Externally-Fired Combined Cycle (EFCC) power system. SiC is the only material that provides the necessary combination of resistance to creep, thermal shock, and oxidation. While the SiC structure materials provide the thermomechanical and thermophysical properties needed for an efficient system, the mechanical properties of the SiC tubes are severely degraded through corrosion by the coal combustion products. To obtain the necessary service life of thousands of hours at temperature, a protective coating is needed that is stable with both the SiC tube and the coal combustion products, resists erosion from the particle laden gas stream, is thermal shock resistant, adheres to SiC during repeated thermal shocks (start-up, process upsets, shut-down), and allows the EFCC system to be ...

1996-06-07

54

Comparative performance of two types of evacuated tube solar collectors in a residential heating and cooling system. The progress report  

Science.gov (United States)

Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of the Corning collector ranged from 49% to 60% of the incident solar energy. The ...

1979-01-01

55

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of ...

1992-01-01

56

Experiences in radioactive gaseous effluent management in JAERI  

International Nuclear Information System (INIS)

In the Japan Research Reactor-II (JRR-2), the main source of _4_1Ar generation is the exhaust air from the horizontal experimental holes and the pneumatic tubes. For the horizontal experimental holes, the flow of exhaust air through the holes was decreased by improving the airtightness, and a decay duct of capacity 2.4 m_3 was installed in the middle of the exhaust line. In consequence, the release rate of _4_1Ar was reduced by 6-8%. For the pneumatic tubes, a mechanical shutter was installed in the tube. The shutter stops the exhaust air flow, except when the pneumatic tube is used. Prior to the use, the activated air in the tube is led to a decay tank. As a result, the _4_1Ar release rate was reduced by 10-20%. By the above means, the yearly exposure at the site boundary was reduced to 0.36 mR from 2.6 mR. In Hot Laboratory for metallurgical examination of spent fuel, the exhaust ...

1983-05-01

57

Development of video probe system for inspection of feeder pipe support in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post- Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And untrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughlv because of narrow and confined accessibility, that is, an inspection space between the pressure tube channels is less than 100mm and pipes in feederpipe support area are congested. And also, workers involved in inspecting ...

2000-07-01

58

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the principles modelling optional boundary ...

2005-07-01

59

Reducing the effect of penstock pressure pulsations on hydro electric plant power system stabilizer signals  

Energy Technology Data Exchange (ETDEWEB)

A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with generator power as the ...

1993-12-01

60

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants; Traitement des signaux de courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of ...

1991-07-01

61

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants. Traitement des signaux courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of ...

1992-01-01

62

Corrosion of support materials  

International Nuclear Information System (INIS)

Results from a heavily fouled 19 tube C-E model boiler test to investigate the potential for egg crate corrosion in aggressively fouled AVT chemistry are reported. Substantial support plate and egg crate corrosion was produced in this test. Carbon steel drilled support plates exhibited extensive denting which resulted in flow hole ligament cracking. Corrosion of the carbon steel egg crate, through-wall at areas of tube contact, resulted in denting of the Alloy 600 heat transfer tubes. Corrosion performance of the 409 stainless steel egg crate was improved compared to the carbon steel egg crate although localized through-wall corrosion was noted. The results from the above test and previously reported tests were compared based on the following simplifying assumptions: maximum dent size and/or corrosion penetrations utilized, average bulk water chloride concentrations, pilling bedworth ratios, pot and model boilers data are ...

1985-03-01

63

Heat transfer augmentation of a circular pipe flow using nano-particle layers  

International Nuclear Information System (INIS)

For the advanced fusion reactor FFHR2 (Force Free Helical Reactor) that has been proposed by NIFS, molten salt Flibe (LiF:BeF2=64:36) breeder blanket system is selected because of Flibe's features such as chemical stability, low-pressure operation and low electric conductivity. The Flibe is however high Prandtl number fluid since it has high viscosity and low thermal conductivity. Therefore its heat transfer performance is low compared with liquid Li or Pb-Li. In addition to heat removal of 1MW/m2 on the first wall, electrolysis of molten salt due to MHD effect will take place under high flow rate condition. This indicates that heat transfer enhancement under low flow rate is essential for the Flibe blanket system. In our laboratory, heat transfer characteristics of molten salt HTS (KNO3:NaNO2:NaNO3=53:40:7), have been evaluated, which is used as a simulant fluid of Flibe from the points of view of Be's toxicity and similar Prandtl number. In ...

2007-10-05

64

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. ...

1999-07-01

65

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. ...

1999-04-19

66

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not ...

1993-06-01

67

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could ...

1994-07-01

68

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not ...

1993-01-01

69

Study on core cooling of hybrid safety system for next-generation PWR during LOCA  

International Nuclear Information System (INIS)

Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the ...

1995-04-23

70

Structural material irradiations in FFTF  

Energy Technology Data Exchange (ETDEWEB)

Information is presented concerning the Materials Open Test Assembly (MOTA); instrumentation and control system; MOTA neutronic data; pressurized tube specimens; stress-rupture measurements for reactor materials; miniature specimen design; the Interim Examination and Maintenance (IEM) cell at the FFTF; support services; and general information concerning the FFTF.

1985-01-01

71

Performance of large LWR system codes in calculating the steam-generator heat-transfer behavior  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a series of modeling experiences and problems in simulating the thermal-hydraulic behavior of large PWR steam generators using the RELAP4 and RELAP5 computer codes. Sensitivity studies investigating the heat transfer characteristics of both once-through and U-tube steam generators are discussed. Suggestions and recommendations are given for effective use and potential future improvements of these codes.

1982-01-01

72

EFFECTIVE CONTROL OF SECONDARY WATER POLLUTION FROM FLUE GAS DESULFURIZATION SYSTEMS  

Science.gov (United States)

The report describes tests to demonstrate the feasibility of using a vertical-tube, falling-film, vapor-compression evaporator to concentrate waste water from a flue gas desulfurization (FGD) process. Tests showed that waste water from the Chiyoda FGD process can be concentrated ...

73

Design of the local trigger board for the Daya Bay reactor neutrino experiment  

British Library Electronic Table of Contents (United Kingdom)

We have designed a local trigger board for the Daya Bay reactor neutrino experiment, which is aimed to measure the neutrino mixing angle sin22?13 with a precision down to 1% level. The local trigger board processes both the total number of coincident photomultiplier tube (PMT) hits and the PMT energy sum to make trigger decisions. With this design, a high trigger probability is achieved to meet the system requirement. The design of the local trigger board is presented.

2011-01-01

74

Design concept and testing of an in-bundle gamma densitometer for subchannel void fraction measurements in the THTF electrically heated rod bundle  

International Nuclear Information System (INIS)

A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.

75

Corrosion resistant coatings for silicon carbide heat exchanger tubes: Topical report  

Energy Technology Data Exchange (ETDEWEB)

This heat exchanger is a critical step in the development of the Externally Fired Combined Cycle power system, a direct-coal combustion power plant (gas turbine). SiC is the only material with the needed resistance to creep, thermal shock, and oxidation; however a protective coating is needed. Ten candidate materials were identified: alumina-based materials, materials stable with SiO, and low expansion materials. An initial screening study should be performed.

1996-09-01

76

Implications of the S-146 model for hideout and return in dented crevices  

International Nuclear Information System (INIS)

As part of Steam Generators Owners Group Project S-146, ''Diffusion and Hideout in Crevices,'' experimental data were obtained on chloride salt hideout and return in a controlled-boiling INCON system containing three electrically heated, thermocouple instrumented tube-to-support-plate intersections. The support plate simulants had first been caused to undergo, in situ, denting-type corrosion to the extent that substantial tube deformation was observed. Then chloride hideout and return measurements were made, using sodium chloride as the impurity additive. Experimental results were fitted to an elementary model for the crevice and its associated transport processes. Details on the experimental work and a description of the data-fitting method are given in the final report, NP-2979, dated March 1983.

1985-03-01

77

Development of electro-optical instrumentation for annular two-phase flow studies. [PWR  

Energy Technology Data Exchange (ETDEWEB)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-05-01

78

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and ...

2002-07-01

79

3D transient calculations of PGV-1000 based on TRAC  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: During calculations of SAR accidents and transients it is necessary to perform steam generator simulation. Best accuracy is 3D transient calculations presented in report. Main outcomes of work was next: 1. There was shown by analysis the applicability of code TRAC (Los-Alamos laboratory) for thermal - hydraulic calculations of horizontal steam generator PGV-1000M. Special nodalization scheme was developed for it purposes. 2. Validation and selection of thermal-hydraulic correlations for improvement of using the code at calculation PGV-1000M were performed. As result Labuntsov formula is recommended for horizontal SG. 3. Calculations of nominal mode operation of PGV-1000M for cross-verification with code STEG (Electrogorsk Research and Engineering Center EREC) during its verification were performed. Solution by TRAC was obtained for transient problem after stabilization time. 4. Development of dynamic SG model as conjugate problem (thermal hydraulic of ...

2005-07-01

80

Rationale for chemical control of feedwater and boiler water. Volume 1. Concentration models. Final report  

Science.gov (United States)

Operating PWR units in the USA have experienced very severe corrosion of the tube support plate at the crevice between the tube and the support. This results in distortion of the plate and crushing of the tube (denting). The first task of this project required that currently available computational methods to estimate the pH attained by concentrating boiler water under various fault conditions such as condenser leakage of river waters and faulty operation of condensate polishing plant. Particular attention has been paid to systems in which sulfate predominates. In the second task, the mechanisms are discussed by which solutions become concentrated in porous deposits on a boiling heat transfer surface. It is concluded that more experimental data are needed to test the validity of existing models. High solution concentrations in the deposit may occur at a heat flux close to the critical value for drying ...

1984-01-01

81

Plasma chemistry in wire chambers  

Energy Technology Data Exchange (ETDEWEB)

The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing ...

1990-05-01

82

Optimisation of solar-heated cavity receivers with paraboloid collectors. Optimierung von solar beheizten Hohlraumstrahlungsempfaengern mit Paraboloidkollektoren  

Energy Technology Data Exchange (ETDEWEB)

The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the ...

1984-01-01

83

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same elevation). Previous ...

1993-01-01

84

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

International Nuclear Information System (INIS)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 ...

1993-07-06

85

Flow regime transition criteria for upward two-phase flow in vertical tubes  

Energy Technology Data Exchange (ETDEWEB)

Traditional two-phase flow-regime criteria based on the gas and liquid superficial velocities may not be suitable to the analyses of rapid transient or entrance flows by the two-fluid model. Under these conditions, it is postulated that direct geometrical parameters such as the void fraction are conceptually simpler and therefore more reliable parameters to be used in flow-regime criteria than the traditional parameters. From this point of view, new flow-regime criteria for upward gas-liquid flow in vertical tubes have been developed considering the mechanisms of flow-regime transitions. These new criteria can be compared to existing criteria and experimental data under steady-state and fully developed flow conditions by using relative velocity correlations. The criteria showed reasonable agreements with the existing data for atmospheric air-water flows. Further comparisons with data for steam-water in round tubes and a rectangular channel at ...

1984-05-01

86

Flow regime transition criteria for upward two-phase flow in vertical tubes  

International Nuclear Information System (INIS)

Traditional two-phase flow-regime criteria based on the gas and liquid superficial velocities may not be suitable to the analyses of rapid transient or entrance flows by the two-fluid model. Under these conditions, it is postulated that direct geometrical parameters such as the void fraction are conceptually simpler and therefore more reliable parameters to be used in flow-regime criteria than the traditional parameters. From this point of view, new flow-regime criteria for upward gas-liquid flow in vertical tubes have been developed considering the mechanisms of flow-regime transitions. These new criteria can be compared to existing criteria and experimental data under steady-state and fully developed flow conditions by using relative velocity correlations. The criteria showed reasonable agreements with the existing data for atmospheric air-water flows. Further comparisons with data for steam-water in round tubes and a rectangular channel at ...

1984-01-01

87

Externally fired combined cycle demonstration  

Energy Technology Data Exchange (ETDEWEB)

Externally Fired Combined Cycles (EFCCs) can increase the amount of electricity produced from ash bearing fuels up to 40%, with overall powerplant efficiencies in excess of 45%. Achieving such high efficiencies requires high temperature-high pressure air heaters capable of driving modern gas turbines from gas streams containing the products of coal combustion. A pilot plant has been constructed in Kennebunk, Maine to provide proof of concept and evaluation of system components. Tests using pulverized Western Pennsylvania bituminous coal have been carried out since April, 1995. The ceramic air heater extracts energy from the products of coal combustion to power a gas turbine. This air heater has operated at gas inlet temperatures over 1,095 C and pressures over 7.0 atm without damage to the ceramic tube string components. Stable gas turbine operation has been achieved with energy input from the air heater and a supplementary gas fired combustor. ...

1995-11-01

88

Experimental study and performance evaluation of convective heat transfer augmentation with coiled wire inserts  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, it is observed that coiled wire turbulence promoters are more ...

1992-12-01

89

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The ...

1995-12-31

90

New monitoring system for microbiological control effectiveness on pitting corrosion of carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A new on-line monitoring system has been developed for pitting corrosion monitoring of carbon steel tubes in cooling water systems. This monitoring system was found to be quite sensitive to the microbiological activity relating to pitting corrosion on a real-time basis. The value of galvanic current indicates the performance level of pitting corrosion inhibition even in biocide application. In addition, the changes in the galvanic current provide indicative information about the effectiveness in microbiological control program, even when the pressure drop measurement indicates no biofilm formation. It can be also useful in detecting a microbiological control upset. In this paper, an introduction of the new monitoring system as a microbiological control effectiveness monitor and the field test results are discussed.

1997-12-01

91

Protective oxides in coal-fired combined cycle power systems  

Energy Technology Data Exchange (ETDEWEB)

In most industrial processes operating at elevated temperatures, protective oxide layers perform a vital duty in protecting the underlying metallic alloys from process gases. Coal-fired combined cycle power generation systems present a number of process conditions in which the properties of the protective oxide layers are particularly important. This paper discusses two of these particular conditions: (1) `erosion/corrosion` of in-bed heat exchanger tubing and (2) thermal cycling of hot gas path components. For both these situations, the desirable properties of protective scales are outlined. The behaviour of scales in practice are highlighted. 33 refs., 6 figs., 2 tabs.

1995-12-31

92

Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.

2002-08-01

93

Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume III. Appendices  

Energy Technology Data Exchange (ETDEWEB)

The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)

1980-04-01

94

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

95

Corrosion 2003. Conference papers on CD-ROM  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.

2003-07-01

96

Tests of Turbulators for Fire-Tube Boilers.  

Science.gov (United States)

... Originator-supplied keywords include: Turbulators, Heat transfer augmentation, Enhancement, Fire tube boilers. (Author). ...

1982-10-01

97

ELECTRON ATTACHMENT OF SEF6  

Science.gov (United States)

... attachment tube which is sketched in Fig. 1. It is mounted inside a cylindrical evacuated tube. A beam of thermal electrons ...

1961-06-20

98

Diaphragm Rupture Effects on an Expanding Flow in a Tube.  

Science.gov (United States)

... The fundamental problem of diaphragm rupture was studied experimentally to determine the effects on an expanding flow in an evacuated tube. ...

1972-08-01

99

Steam generator tube denting-criteria for tube plugging  

International Nuclear Information System (INIS)

When steam generator tube denting was identified, steps were taken to retard the rate of corrosion and to develop corrective measures if possible. Techniques were developed to determine the exact shapes of the tubes, and procedures were devised to analyze resulting strain and operating stresses. Tube plugging criteria were established, and in twelve years of operation, there has been only one instance of a forced outage due to a tube leak.

100

State-of-the-art technology for production of seamless tubes in zirconium and titanium alloys  

International Nuclear Information System (INIS)

Zircaloy fabrication plant manufactures all the necessary Zr-2 components like fuel canning tubes, calandria tubes and other rod and sheet products. This plant is having a capacity of producing about 4 lakh nos. of PHWR fuel tubes per annum. These tubes are seamless, thin walled with close dimensional tolerances and stringent mechanical properties. The plant has established all the facilities required to produce these tubes with required quality.

101

rf system for the Los Alamos free-electron laser (FEL)  

Energy Technology Data Exchange (ETDEWEB)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 ..mu..s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2/sup 0/, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-..mu..s pulses. Each ...

1983-01-01

102

rf system for the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are +-1/2_0, and +-1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each ...

1983-03-21

103

The RF system for the Los Alamos free electron laser (FEL)  

International Nuclear Information System (INIS)

The FEL electron linac consists of three buncher cavities: two accelerator cavities and a deflection cavity, each with its own phase-coherent rf source. All sources will be pulsed for 100 #mu#s at a 1-pps rate. The phase and amplitude stability requirements are + or - 1/2"0, and + or - 1/2%. There are two subharmonic bunchers, each requiring 5 kW at 108.33 MHz. All remaining cavities operate at 1300 MHz. The fundamental buncher requires 5 kW, whereas each of the accelerating cavities requires at least 3 MW. The deflection cavity requires up to 100 kW, which is coupled from one of the accelerator cavity rf sources. Prominent features of the rf system are the phase and amplitude control circuits and the multimegawatt klystron amplifiers. Three L3707 klystrons were obtained from the AMRAD radar site at White Sands, which was decommissioned in the early 1970s. The tubes originally were designed to produce 10-MW, 10-#mu#s pulses. Each ...

104

Determination of the distribution of incident solar radiation in cavity receivers with approximately real parabolic dish collectors  

Energy Technology Data Exchange (ETDEWEB)

The absorption of solar heat and the attendant thermal and mechanical loadings on the tubes of cavity receivers depend predominantly on the flux distribution of the incident solar radiation. For an axially symmetric cavity receiver with a parabolic dish collector, it is simple to determine the insolation pattern on the receiver internal surfaces if the system is ideal. In such a system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun's central ray impinges on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions cannot be achieved in practice, and therefore the feasible parabolic dish system is referred to as a real system although, in actual fact, it is only an approximation to any actual system. The purpose of this paper is to devise calculation principles which ...

1990-11-01

105

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

106

Linearized augmented-plane-wave method for quasi-unidimensional systems: Carbyne and nanotube (Sc@C{sub 20})  

Energy Technology Data Exchange (ETDEWEB)

The advent of carbon nanotubes, which are graphite layers convoluted in cylinders several nanometers in diameter and several micrometers in length, as well as the experiments on implanting metal atoms in such tubes open the way to producing nanoconductors and other materials with unique properties. For theorists, the basic challenge is interpreting and predicting the structure and properties of these systems. The linearized augmented-plane-wave method (LAPW) is one of the most accurate methods in the theory of the electronic structure of solids. A generalization of this method for quasi-two-dimensional systems, surface electronic states, and layered crystals is known. The LAPW theory for quasi-unidimensional systems, which exhibit translational symmetry in one direction, has been absent thus far. In this paper, the authors suggest a version of such a theory and use this method to calculate the ...

1995-10-01

107

A miniaturized spatial temperature gradient capillary electrophoresis system with radiative heating and automated sample introduction for DNA mutation detection  

British Library Electronic Table of Contents (United Kingdom)

Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...

2010-01-01

108

Loading of wellbores with explosives  

Energy Technology Data Exchange (ETDEWEB)

Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube ...

1983-04-26

109

Economic evaluation of four types of dry/wet cooling applied to the 5-MWe Raft River geothermal power plant  

Energy Technology Data Exchange (ETDEWEB)

A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had the isobutane ducted ...

1982-07-01

110

A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will ...

2007-10-29

111

Design and performance of radioisotope space power systems based on OSC multitube AMTEC converter designs  

Energy Technology Data Exchange (ETDEWEB)

This paper extends the analytical procedure described in another paper in these proceedings to analyze a variety of compact and light-weight OSC-designed radioisotope-heated generators. Those generators employed General Purpose Heat Source (GPHS) modules and a converter containing sixteen AMTEC cells of OSC`s revised five-tube design with enhanced cell wall reflectivity described in a companion paper in these proceedings. OSC found that the performance of the generator is primarily a function of the thermal insulation between the outside of the generator`s 16 cells and the inside of its wall. After examining a variety of insulation options, it was found that the generator`s performance is optimized by employing a hybrid insulation system, in which the space between the cells is filled with fibrous Min-K insulation, and the generator walls are lined with tapered (i.e., graded-length) multifoil insulation. The OSC design results in a very compact ...

1997-12-31

112

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

Energy Technology Data Exchange (ETDEWEB)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.

1982-10-01

113

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

International Nuclear Information System (INIS)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).

1982-01-01

114

Computer modelling of eddy current probes for ISI of pressure tube/calandria tube assemblies in PHWRs  

International Nuclear Information System (INIS)

Non-destructive Evaluation (NDE) plays a major role in ensuring the safe and reliable operation of PHWRs which are the mainstay of India's nuclear power programme. An important in-service inspection (ISI) requirement in these reactors is carried out through Eddy Current Testing (ECT) of the pressure tube (PT)/calandria tube (CT) assemblies. The material of construction of these assemblies is zircaloy-2. The two main objectives of this ISI are the detection of garter spring between CT and PT and the profiling of gap between CT and PT. The paper discusses the work carried out at the authors' laboratory on the development of ECT probes for ISI of PT/CT assemblies. Emphasis has been given on the work done on the design and optimisation of the probes using computer modeling. A 2-D finite element code has been developed for this purpose. The code is developed around a diffusion equation which can be derived from Maxwell's equations governing the ...

1991-12-01

115

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

Energy Technology Data Exchange (ETDEWEB)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for ...

2010-05-15

116

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

International Nuclear Information System (INIS)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for ...

2010-05-01

117

Prediction of the lifetime behaviour for C/C-SiC tubes as high and ultrahigh temperature heat exchangers (HITHEX) - material characterisation and qualification  

Energy Technology Data Exchange (ETDEWEB)

Heat exchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heat exchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction between coating system and basic material ...

2004-07-01

118

STATUS OF THE DIELECTRIC WALL ACCELERATOR  

Energy Technology Data Exchange (ETDEWEB)

The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.

2009-04-22

119

Real-time imaging for neutron radiography at KURRI  

International Nuclear Information System (INIS)

For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).

1987-07-01

120

Electrical Transmission Line Diametrical Retention Mechanism  

Science.gov (United States)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

2006-01-03

121

Charging a Battery-Powered Device with a Fiber-Optically Connected Photonic Power System for Achieving High-Voltage Isolation  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development and testing of a system to provide isolated power to the cathode-subsystem electronics of an x-ray tube. These components are located at the cathode potential of several hundred kilovolts, requiring a supply of power isolated from this high voltage. In this design a fiber-optically connected photonic power system (PPS) is used to recharge a lithium-ion battery pack, which will subsequently supply power to the cathode-subsystem electronics. The suitability of the commercially available JDSU PPS for this application is evaluated. The output of the ppe converter is characterized. The technical aspects of its use for charging a variety of Li-Ion batteries are discussed. Battery charge protection requirements and safety concerns are also addressed.

2008-01-01

122

Bioreactors  

Energy Technology Data Exchange (ETDEWEB)

Composting is once again gaining interest among ecological engineers in view of greener industrial and residential activities. Uniform composting is needed to ensure decomposition and to keep the whole system at the same composting stage. A homogeneous temperature must be maintained throughout the media. A bioreactor design consisting of a heater core made of copper tubing was designed and tested. Two four-inch holes were made at the top and bottom of the barrel to allow air to flow through the system and promote aerobic composting. Once composting began and temperature increased, the water began to flow through the copper piping and the core heat was distributed throughout the medium. Three thermocouples were inserted at different heights on a 200 litre plastic barrel fitted with the aforementioned apparatus. Temperature variations were found to be considerably lower when the apparatus was operated with the heat ...

2010-07-01

123

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

124

Understanding and protecting steam generator materials  

Science.gov (United States)

Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.

1986-01-01

125

Understanding and protecting steam generator materials  

International Nuclear Information System (INIS)

Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.

1986-11-16

126

Temperature dependence of molar excess volumes for the dimethyl sulfoxide + thiophene system and thermal expansion coefficients between 293. 15 and 313. 15 K  

Energy Technology Data Exchange (ETDEWEB)

Densities were measured with a vibrating-tube densimeter for binary mixtures of dimethyl sulfoxide + thiophene at temperatures from 293.15 to 313.15 K as a function of composition. Molar excess volumes V[sup E] for the mixtures, determined from the density data, are negative and become more negative with an increase in temperature. The coefficients of thermal expansion were also evaluated from the temperature dependence of the density.

1993-04-01

127

Synthesis and photonic band calculations of NCP face-centered cubic photonic crystals of TiO2 hollow spheres.  

Science.gov (United States)

With the help of self-assembly, thermal sintering, selective etching techniques and sol-gel process, the non-close packed (ncp) face-centered cubic (fcc) photonic crystals of titanium dioxide (TiO2) hollow spheres connected by TiO2 cylindrical tubes have been fabricated using silica template. The photonic bandgap calculations indicate that the ncp structure of TiO2 hollow spheres was easier to open the pseudogaps than close packed system at the lowest energy. PMID:17097102

2006-10-21

128

PLZT electrooptic shutters: applications  

Science.gov (United States)

Advances in the development of several electrooptic shutter devices utilizing the quadratic electrooptic effect of lead lanthanum zirconate titanate (PLZT) ceramic wafers are described. Aperture sizes utilized in these PLZT devices ranged from 25 ..mu..m to 0.25 m. Practical applications of the shutters discussed in this paper include eye protection in military and industrial applications, a goggle-type device with dual synchronously operated PLZT shutters for use in a stereoscopic three-dimensional TV display, an electrically controlled variable density filter for use with vidicon tubes, a large-aperture photographic shutter for image motion compensation cameras, and a page composer for use in a holographic memory system.

1975-08-01

129

Methodology for fabrication of hydraulics mini turbines with composite materials; Metodologia para a fabricacao de mini turbinas hidraulicas com materiais compostos  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the description of methodological procedure specially developed for manufacturing mini turbines. This procedure is used in the design of a Francis type mini turbine with 12.5 kW. The housing volute and the suction tube of this equipment are manufactured with using composed material based on glass fiber and its distributor system is manufactured with stainless steel and brass. At the end it is presented an estimate cost of design / manufacturing of such equipment and a comparison with other equipment in the market.

2009-07-01

130

Literature and patent searches on the subject of controllable heat transfer. Final report. Literatur- und Patentrecherche zum Thema Schaltbarer Waermedurchgang. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.

1989-01-01

131

FADC signal reconstruction for the MAGIC telescope  

Energy Technology Data Exchange (ETDEWEB)

Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.

2008-09-11

132

Bring fresh ideas to boiler startup procedures  

Energy Technology Data Exchange (ETDEWEB)

This article describes innovations in new-boiler startups, based on experiences at United Development Group`s 50-MW Niagra cogeneration facility, Niagra Falls, NY. The plant comprises: a circulating coal fluidized bed boiler supplying steam to a nearby factory and electricity to the grid. Before operation the system was flushed with demineralized water, and the boiler degreased, the steam blow relied on a new procedure involving a continuous flow of steam. Startup was then initiated, following manufacturers heatup rate and soak times closely. After startup boiler tube sections were checked, and cleaned if necessary. 1 fig.

1996-05-01

134

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were ...

1346-01-01

135

The Rab GTPase RabA4d Regulates Pollen Tube Tip Growth in Arabidopsis thaliana[W  

UK PubMed Central (United Kingdom)

During reproduction in flowering plants, pollen grains form a tube that grows in a polarized fashion through the female tissues to eventually fertilize the egg cell. These highly polarized pollen tubes...Full Text Available

2009-02-01

136

The Experimental Determination of the Thermodynamic and Hydrodynamic Mechanism of Augmented Flow Boiling in Tubes.  

Science.gov (United States)

Experimental results are presented for a new and unique heat transfer augmentation technique in tubes. The technique consists of inserting a porous mesh structure into the flow passage of the tube. Due to the increased degree of turbulence, both the singl...

1970-01-01

137

In service inspection for steam generator tubes  

International Nuclear Information System (INIS)

In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.

1987-11-24

138

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring ...

1988-09-01

139

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time ...

1988-01-01

140

Secondary side concept to prevent steam generator tube corrosion  

International Nuclear Information System (INIS)

Some examples are given of design adaptations, e.g. U-bend support, tube spacer grid, flow distribution baffle, triangular tube pitch, tube-tubeplate sheet connection, which reduce the tendency to various types of corrosion (stress corrosion cracking, tube denting, tube wastage, intergranular cracking). A basic diagram of the secondary circuit is shown. Oxygen, corrosion product and impurity control in the secondary circuit is described. (E.J.). 19 figs., 6 refs.

1989-05-01

141

Graphitic nano tubes and aligned nano tubes films  

Energy Technology Data Exchange (ETDEWEB)

Carbon nano tubes are easily produced in macroscopic quantities, however their characterisation and possible applications are still rather limited. We have developed a new method to make aligned nano tube films which open new opportunities, not only for basic research but also for eventual applications. With this method the tubes can be aligned either parallel or perpendicular to the surface. We give a short review of the microscopic properties of single tubes and the bulk properties of the aligned films. (author). 24 refs., 6 figs.

1996-03-01

142

Film condensation of HCFC-22 on horizontal enhanced tubes  

Science.gov (United States)

Experiments were conducted to study the condensation heat transfer characteristics of horizontal enhanced tubes. In the current experiment, six different enhanced tubes, including 26, 40 fpi low fin tubes and four three-dimensional-fin tubes, were tested. The working fluid used in the experiment was HCFC-22. Data were presented in the form of overall heat transfer coefficient at three working pressures, namely 1.32, 1.47 and 1.62 Mpa. In addition, the condensing heat transfer coefficients for the test tubes were obtained from the Wilson plot technique.

1996-01-01

143

Understanding of the volatility of GeO/sub 2/ in the presence of WO/sub 2/  

Energy Technology Data Exchange (ETDEWEB)

The equilibria composition of the gaseous and the solid phase in the system GeO/sub 2//WO/sub 2/ is calculated with an improved thermodynamical program for temperatures 1100 < T < 1400 K and constant volume. By means of the results the experimental observed migration of GeO/sub 2/ in the presence of WO/sub 2/ in a temperature gradient T/sub 2/ ..-->.. T/sub 1/ (1200 ..-->.. 1100 K) in sealed evacuated silica tubes is due to a chemical transport with H/sub 2/ as the transporting agent. The H/sub 2/ is formed by H/sub 2/O which is desorbed by the quartz glass of the ampoules. The also observed volatility of WO/sub 2/ and its deposition in form of Ge/sub 0.75/W/sub 3/O/sub 9/ at the 'cold' end (T/sub 1/) of the tubes is performed by gaseous GeWO/sub 4/. The calculated and experimental transport rates are compared and discussed.

1983-08-01

144

Thermal energy storage system using stearic acid as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and steady phase change characteristics than in the vertical ...

2001-07-01

145

The application of high pH operation to the secondary water chemistry at Genkai Nuclear Power Station  

International Nuclear Information System (INIS)

PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the secondary water ...

2009-02-01

146

Stochastic-convective transport with nonlinear reaction: Mathematical framework  

Energy Technology Data Exchange (ETDEWEB)

A stochastic-convective reactive (SCR) transport method is developed for one-dimensional steady transport in physically heterogeneous media with nonlinear degradation. The method is free of perturbation amplitude limitations and circumvents the difficulty of scale dependence of phenomenological parameters by avoiding volume-averaged specifications of diffusive/dispersive fluxes. The transport system is conceptualized as an ensemble of independent convective-reactive streamlines, each characterized by a randomized convective velocity (or travel time). Dispersive effects are treated as a component of the randomness in the streamline velocity ensemble, so no explicit expression for hydrodynamic dispersive flux is written in the streamline transport equation. The expected value of the transport over the stream tube ensemble is obtained as an average of solutions to the reactive convection equation according to the stream tube ...

1995-11-01

147

Removal of iodine from nuclear fuel reprocessing plant off-gases by Corona discharge  

International Nuclear Information System (INIS)

Corona discharge has been investigated for the treatment of off-gases arising from nuclear fuel reprocessing operations, in particular Dissolver off-Gases (DOG). Results are presented of studies carried out on single tube, wire-in-tube experimental rigs to examine the behaviour of molecular iodine, organic iodine and oxides of nitrogen (NOx). The effect of corona current, gas residence time, electrode configuration, oxygen concentration and moisture content are discussed. Decontamination Factors (DF's) of greater than 104 (> 99.99% removal) have been achieved for both molecular and organic iodine. Efficient NOx removal has also been demonstrated. Moisture and NOx both interfere with iodine removal above certain concentrations. To overcome this a two stage corona system has been developed consisting of a primary continuously irrigated corona unit followed by a dehumidifier prior to a secondary dry corona unit.

1991-10-21

148

Hydrodynamic studies of post dryout two-phase downflow in narrow channels  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of the hydrodynamics of a narrow channel was performed in order to obtain the heat transfer mechanisms and influences contributing to the flow regime transition from inverted annular to inverted slug flows for post dryout downflow. The experimental series consisted of both adiabatic and diabatic visualization tests over a wide range of fluid and thermal parameters. The system inlet gas velocities ranged from 0 to 14 meters per second while the inlet fluid velocities ranged from 1 to 3 meters per second. Full extent visualization of the flow regime was possible due to a quartz tube in tube construction with a clear heating fluid. Constant temperature heating of the freon was accomplished at bulk fluid temperatures above the critical heat flux temperature. For each hydrodynamic flow condition, one to three minuets of VHS-video filming was performed to acquire both flow regime and break-up length data. In ...

1995-07-01

149

Historical development of alloy 800  

International Nuclear Information System (INIS)

Alloy 800 was developed in 1949 by The International Nickel Company, Inc. The basic composition, nominally 32wt.%Ni, 20.5wt.%Cr and 46wt.%Fe, was designed to provide a stable, fully austenitic structure and to impart high strength combined with resistance to oxidation, carburization and corrosion in a wide variety of aggressive industrial environments at elevated temperatures. In the short span of twenty-five years, alloy 800 has earned a unique position in the family of heat- and corrosion-resistant materials. Established uses include a wide range of applications in the industrial heating field, in the petro-chemical industry, in domestic appliances and in food processing equipment. The good performance of alloy 800 in these applications has led to its use as boiler tube material both in fossil-fired plants and in HTGR and PWR nuclear power systems. Recently, it was specified for a PHW CANDU reactor and it is now being considered as heat ...

150

Effect of dissolved oxygen on denting corrosion  

International Nuclear Information System (INIS)

The following conclusions are drawn from the study of the effects of dissolved oxygen on corrosion denting: 1) Following the ingress of fresh-water contamination into a PWR boiler, an acidic chloride solution can be formed in the crevice between tube and tube support plate when an oxidant such as dissolved oxygen or copper ions is present in the boiler water. 2) In the absence of copper, very high levels of dissolved oxygen and neutral chloride are necessary to initiate corrosion. 3) When copper is present in the feed system, sufficient copper ions to initiate corrosion within the crevice are released when the chloride concentration is 0.8 mg/kg and probably also at lower chloride values. Corrosion initiation however may require prior exposure of the copper to dissolved oxygen and can be suppressed by pretreatment with hydrazine. 4) The effect of dissolved oxygen on corrosion already occurring was not explored; neither was ...

1985-03-01

151

Development and performance of a miniature, high-voltage thermal battery  

Science.gov (United States)

A miniature, high-voltage, thermally activated battery has been developed. This battery weighs 41 grams, occupies a volume of 16.4 cu cm, and contains two separate 500-v channels, each designed to charge a 5.25 microfarad capacitor within 300 milli-seconds and remain operational under a 640-kohm load for a minimum of 28 seconds over the temperature range from +16 to +71 C. The electrochemical system utilizes a calcium anode, LiCl-KCl molten salt electrolyte, a CaCrO4-K2CrO4 mixture as the depolarizer or active cathode material, and an iron cathode. The depolarizer and electrolyte, along with a silica binder, are formed into homogeneous pellets, and these pellets are stacked alternately with calcium-iron bimetal disks in beryllium oxide tubes to form cell stacks. The cells are activated by an iron-potassium perchlorate pyrotechnic heat source external to the BeO tubes.

1974-01-01

152

Corrosion failure and its prevention in light water reactor power plants  

Energy Technology Data Exchange (ETDEWEB)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. ...

1988-01-01

153

Corrosion failure and its prevention in light water reactor power plants  

International Nuclear Information System (INIS)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. ...

154

Approximate analysis of non-uniform gas flow through layered burdens  

Energy Technology Data Exchange (ETDEWEB)

An approximate analyzing model was developed to predict the azimuth of zigzag streamline, the distribution ratio between two neighboring layers and the radial distribution among the layers of the gas passing through the shaft of blast furnace loaded in layers. The theoretical basis of the approximate analysis is composed of the material balance derived from the assumption that any stream line surrounded with two streamlines is isolated and no material transfer occurs through the tube wall, and of the energy theory that the stream tube and passage are formed so that the total pressure drop in the whole system is the minimum. The effects of the apparent angle of repose between two layers, the packing volume and the passage resistance on the non-uniform flow in the layer were evaluated on the basis of the model. The result calculated by the approximate analysis agrees with the result by the numerical analysis based on the ...

1988-02-01

155

State of the art simulations of magnicon  

International Nuclear Information System (INIS)

The magnicon is a highly attractive candidate to be the RF source for a future multi-Tev linear collider. Physical models and computer codes have been developed which can provide start-to-end self-consistent simulations of a magnicon, including precise simulations of the high-convergence electron gun, RF-system, magnetic system, and beam collector. The 3-D beam dynamics simulations include realistic fields, finite beam size and transverse space charge effects. The codes allow one to provide steady-state simulations of the entire tube, so as to evaluate transient process of magnicon excitation, parasitic mode self-excitation, stability analysis, and tolerance analysis. The results of the simulations are found to be in good agreement with magnicon experiments. A brief description of the physical models and simulation codes employed will be given.

2002-12-12

156

ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM  

Energy Technology Data Exchange (ETDEWEB)

This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period October 1, 2004 through December 31, 2004. The following tasks have been completed. First, the renovation of the new Combustion Laboratory and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building have proceeded well. Second, the detailed design of supporting and hanging structures for the CFBC was completed. Third, the laboratory-scale simulated fluidized-bed facility was modified after completing a series of pretests. The two problems identified during the pretest were solved. Fourth, the carbonization of chicken waste and coal was investigated in a tube furnace and a Thermogravimetric Analyzer (TGA). The experimental results from this study are presented in this report. Finally, ...

2005-01-30

157

A hybrid solar desalination process of the multi-effect humidification dehumidification and basin-type unit  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a hybrid solar desalination process of the multi-effect humidification dehumidification and the basin-type unit. The sketch of the hybrid solar desalination process is given. The solar vacuated tube collector is employed in the desalination system, multi-effect humidification dehumidification desalination (HDD) process is plotted according to pinch technology, and then the water rejected from multi-effect HDD process is reused to desalinate in a basin-type unit further. The gain output ratio (GOR) of this system will rise by 2?3 at least through reusing the rejected water. The research proves that the multi-effect HDD has much room to be improved. A hybrid solar desalination process of the multi-effect humidification dehumidification and the basin-type unit should be no...

2008-01-01

158

Thoracoscopy in Children: Is a Chest Tube Necessary?  

UK PubMed Central (United Kingdom)

PurposeHistorically, a chest tube or drain has been left following a thoracic operation to allow drainage of air or fluid in the postoperative period. However, in...Full Text Available

2009-04-01

159

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters  

Science.gov (United States)

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters

1987-03-01

160

Development of technology on the material surveillance of CANDU pressure tubes  

International Nuclear Information System (INIS)

Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test ...

1997-05-21

161

An Optical Fiber Infrasound Sensor  

Science.gov (United States)

... We use a compliant, sealed tube helically wrapped with an optical fiber. ... 2.5 cm diameter compliant, sealed tube 10 m < length < 120 m ...

2000-09-01

162

A comparative analysis of passive twin tube and skyhook MRF dampers for motorcycle front suspensions  

Science.gov (United States)

A comparative analysis between conventional passive twin tube dampers and skyhook-controlled magneto-rheological fluid (MRF) dampers for motorcycle front suspensions is provided, based on single axis testing in a damper test rig and suspension performance testing in road trials. Performance motorcycles, while boasting extremely light suspension components and competition-ready performance, have an inherent weakness in comfort, as the suspension systems are designed primarily for racing purposes. Front suspension acceleration and shock loading transmit directly through the front suspension triple clamp into the rider's arms and shoulders, causing rapid fatigue in shoulder muscles. Magneto-rheological fluid dampers and skyhook control systems offer an alternative to conventional sport motorcycle suspensions - both performance and comfort can be combined in the same package. Prototype MRF dampers designed and manufactured ...

2004-07-01

163

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between ...

1999-07-01

164

Supporting Thermal Hydraulic Calculations for the SGTR Event Tree of SMART Level 1 PSA  

International Nuclear Information System (INIS)

SMART (System integrated Modular Advanced ReacTor) , is under development at the Korea Atomic Energy Research Institute (KAERI). SMART is an integral type pressurized water reactor which contains a pressurizer, 4 reactor coolant pumps (RCPs), and 8 steam generator cassettes(S/Gs) in a single reactor vessel. This reactor has substantially enhanced its safety with an integral layout of its major components, 4 trains of safety injection system (SIS), and an adoption of 4 trains of passive residual heat removal system (PRHRS) instead of an active auxiliary feedwater system . The thermal power is 330 MWth. During the conceptual design stage, a preliminary PSA was performed. PSA results identified that a steam generator tube rupture (SGTR) is one of the most important initiating events which results in a high core damage frequency. Clear understanding of accident progression with various ...

2010-10-01

165

PILC cable technology and accessories  

Energy Technology Data Exchange (ETDEWEB)

Studies were conducted to examine the pressure on fluid-filled cables of electric power transmission networks in the event of an oil leak. Transition splices between paper-insulated oil-impregnated cable systems (PILC) and solid dielectric cable is difficult to perform. A proper PILC is composed of a means to contain oil within the cable structure and to keep moisture out. A failure of the cable joint could occur if an oil leak dries out the paper. Since oil pressure in most PILC cables is high, strong mechanical means must be devised to contain the oil within the cable. Resin systems, heat shrink systems and wiped lead sleeves to reseal the PILC cable over the splice, are among the methods used to stop an oil leak. A system has been designed using an EPDM tube contained under mechanical pressure; it has proven to be effective over a wide range of pressure conditions. Test results ...

1996-08-01

166

Experience with fully operational solar-driven 10-ton LiBr/H2O single-effect absorption cooling system in Thailand  

British Library Electronic Table of Contents (United Kingdom)

A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...

2008-01-01

167

Cracking of Alloy 800 tubing in superheated steam in a solar receiver  

Energy Technology Data Exchange (ETDEWEB)

The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the ...

1985-10-01

168

Thermal convection loop study of corrosion of alloy 800 in molten NaNO/sub 3/-KNO/sub 3/  

Energy Technology Data Exchange (ETDEWEB)

Maximum metal loss rate of Alloy 800 coupons was about 0.5 mil/year and occurred at the maximum temperature of 600/sup 0/C. Significantly greater oxide penetration into the alloy occurred in unabraded as-received tubing. Since the corrosion rate of unabraded tubing was less temperature sensitive than polished coupons, and attained a maximum value at temperatures in the range of 550 to 565/sup 0/C, a value of 1 mil/year should be used as the corrosion rate for design purposes. Because daily thermal cycling is inherent in solar central receiver operation, oxidation and chromium depletion rates can be expected to increase if surface oxide layers spall. The oxide layers formed on Alloy 800 appeared to be adherent, and adherence will benefit further from growth-derived compressive stresses in oxide layers on the salt-exposed inner diameter of receiver tubes. Since the lower duty factor in diurnal solar service may offset the ...

1983-01-01

169

PFB coal fired combined cycle development program. Commercial plant requirements definition update (Task 1. 1)  

Energy Technology Data Exchange (ETDEWEB)

The Coal Fired Combined Cycle (CFCC) power system thermodynamic cycle is illustrated schematically. Pressurized air supplied at the discharge of gas turbine compressors is ducted to the pressure vessel of pressurized, fluidized-bed, combustor-steam generator modules. The air is introduced in parallel to the beds, entering through distribution grids beneath each bed. Steam generation tubes are buried within the beds and are also arranged as membrane tube walls enclosing the four sides. Crushed coal (1/4 inch x 0) is pneumatically fed at locations just above the air inlet grids at the bottom of each bed. Dolomite is similarly fed to the individual beds. The coal is burned at a temperature below the ash fusion point. Sulfur is removed in the fluid beds through reaction of the SO/sub 2/ with CaCO/sub 3/ and O/sub 2/ to form solid CaSO/sub 4/ and CO/sub 2/ gas. The combustion gases leave the beds at a temperature in the range of ...

1980-05-01

170

Eddy current signal analysis techniques for assessing degradation of support plate structures in nuclear steam generators  

Energy Technology Data Exchange (ETDEWEB)

The steam generator (SG) is one of the most critical components of the heat transfer system in nuclear generation stations. Testing the structural integrity of SG tubing and SG internals is a key element of the fitness-for-service assessments to assure the safe and continuous operation of nuclear power plants. Recent eddy current (ET) inspections of two nuclear power plants revealed degradation of some of the tube support plate (TSP) structures, which was also confirmed by visual inspection. The phenomena was described as metal loss, caused by flow-accelerated corrosion of the carbon steel trefoil support plate and varying from minor to complete loss of the ligaments. This loss of TSP ligaments results in lack of support for the adjacent tubes making them more susceptible to fretting-wear damage and fatigue cracking. A signal analysis method, based on the responses at low frequency of two types of eddy ...

2006-07-01

171

A study of passive and inherent safety design concepts for advanced light= water reactors  

Energy Technology Data Exchange (ETDEWEB)

The five thermal-hydraulic concepts chosen for conceptual study of advanced PWR systems have been studied as follows: (1) Critical Heat Flux in passive PWR Conditions: review of previous works (various of correlations, analysis of parametric trends) on CHF, assessment and improvement of CHF prediction models for round tubes, development of the prediction model on bundle CHF with considering the correction factor calculated from the tube data base, design and construction of the intermediate-pressure CHF experimental loop, extension of CHF data base by performing the experiments at low-flow, and low-quality conditions (2) Passive Cooling Concepts for Concrete Containment Systems: Selection of the external condenser by comparing and reviewing between passive cooling concepts for concrete containment system concepts, survey and review of previous studies (theoretical mechanism of ...

1997-07-01

174

Experimental investigation for fluid flow and heat transfer in a rotating tube with twisted-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation was carried out for friction factor and heat transfer coefficient in the case of a rotating tube with a twisted-tape insert for heat transfer augmentation. The data obtained were compared with existing data for a stationary tube with a twisted-tape insert. It has been observed that the enhancement in heat transfer offsets the rise in friction factor due to rotation, with respect to a plain tube under stationary conditions. A correlation has been proposed for the data obtained.

1995-04-01

176

Microprocessor system controlling gas-carburizing process  

Energy Technology Data Exchange (ETDEWEB)

This report introduces a microprocessor system composed of a Z-80 single-board computer controlling a gas-carburizing process. The system has 7 analogical input and output signals 24 switch signal-input and 12 switch signal-output signals, which are applicable for temperature, carbon potential, and mechanical-movement control of multipurpose sealed furnaces, or for mutiple-zone temperature, carbon potential, and mechanical-movement control of continuous gas carburizing furnaces; or for distributed control of pit-type carburizing furnaces. The setpoints of variables, such as treating time, temperature, carbon potential of carburizing period, carbon potential of diffusion period, depth of carburizing layer, P.I.D. etc., are entered by keyboard and stored into memories, and actual values are displayed by digital tubes. Furthermore, the fault of thermocouple, oxygen probe, or infrared CO/sub 2/ analyzer; carbon potential, or ...

1986-01-01

177

Iron Aluminide Hot Gas Filters  

Energy Technology Data Exchange (ETDEWEB)

Currently, high temperature filter systems are in the demonstration phase with the first commercial scale hot filter systems being installed on integrated gasification combined cycle (IGCC) and pressurized fluid bed combustion cycle (PBFC) systems (70 MW). They are dependent on the development of durable and economic high temperature filter systems. These filters are mostly ceramic tubes or candles. Ceramic filter durability has not been high. Failure is usually attributed to mechanical or thermal shock: they can also undergo significant changes due to service conditions. The overall objective of this project is to commercialize weldable, crack resistant filters which will provide several years service in advanced power processes. The specific objectives of this project are to develop corrosion resistant alloys and manufacturing processes to make Iron Aluminide filter media, and to ...

1996-12-31

178

Field performance of an energy pile system for space heating  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heat exchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heat exchanger inside the pile, and a U-tube type underground heat exchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average coefficient of performance for space heating was quite high at 3.9, and the seasonal primary energy reduction ...

2007-05-15

179

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications  

Energy Technology Data Exchange (ETDEWEB)

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the ...

2009-06-17

180

A thermochemical hydrogen production system based on a high-temperature fusion reactor blanket  

International Nuclear Information System (INIS)

A conceptual fusion synfuel production system has been developed with the unique features of: (1) a fusion blanket producing high-temperature (1250"0C) process heat, and (2) the GA sulfur-iodine thermochemical cycle. The system incorporates a two-zone blanket which achieves a tritium breeding ratio of 1.1 while delivering a high fraction (30%) of the fusion heat at high temperatures (1250"0C). The multiple barriers to tritium permeation in the blanket design permit the hydrogen product to meet 10CFR20 regulatory requirements without stringent requirements on the tritium recovery systems. A ceramic heat exchanger, incorporating SiC tubes and headers to contain the process stream and a cooled, Inconel 718 pressure shell to contain the helium, was designed for transferring the heat from the high-temperature coolant to the process. A good heat-line match of the blanket heatsource temperature distribution to ...

1983-04-26

181

Tube bundle for a heat exchanger  

International Nuclear Information System (INIS)

The tube bundle arrangement is suitable as reheating section of a steam generator in combination with a gas-cooled reactor. For any high-temperature section with a straightline type tube bundle, there is one inlet and one outlet collecting main; these two are arranged one opposite to the other and diametrically to the tube bundle. There are a number of lines from the inlet collecting main to the outlet collecting main; these lines are arranged axially one on top of the other and run around the tube bundle helically several times. (GL) 891 GL/GL 892 MB.

182

Steam generator tube performance  

International Nuclear Information System (INIS)

A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.

2005-10-27

183

Control Rod Ejection Accident while Using 6- and 8-Tube IRT-4M Fuel Assemblies in WWR-SM Research Reactor Core  

Energy Technology Data Exchange (ETDEWEB)

The WWR-SM reactor at the Institute of Nuclear Physics of the Academy of Sciences (INP AS) in Uzbekistan was converted to 6-tube IRT-4M LEU (19.7%) fuel in 2009. Presently, INP intends to also use IRT-4M 8-tube FA, and a safety analysis for these 'mixed' (8-tube and 6-tube FA) cores is required by the regulatory authorities. This paper presents results of control rod ejection transient analysis for these mixed cores

2011-07-01

184

[Molecular analysis of cytoplasmic male sterility]. Progress report, June 1, 1989--June 15, 1991  

Energy Technology Data Exchange (ETDEWEB)

We have determined the actual RNA sequence of four mitochondrial genes: pcf, nad3, rps12, and coxII. Because plant mitochondrial proteins cannot be predicted from DNA sequences, the actual primary structures of the encoded proteins were unknown. We have gained information concerning the process of RNA editing. Editing can occur before splicing. Our data is consistent with the hypothesis that RNA editing is not simultaneous with transcription. Unlike other systems, the process of editing in plant does not exhibit a discernable direction. As a result of our RNA editing studies, we have produced a number of clones of the proper coding regions tube used for incorporating these mitochondrial genes into the nucleus. 6 refs., 4 figs.

1991-12-31

185

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

186

Two-stage solar multi-effect humidification dehumidification desalination process plotted from pinch analysis  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a two-stage solar multi-effect humidification dehumidification desalination process plotted from pinch analysis. The sketch of two-stage solar multi-effect humidification dehumidification desalination process is given. The solar vacuated tube collector is employed in the desalination system, multi-effect humidification dehumidification desalination (HDD) process are plotted two different temperature range according to pinch technology. The higher temperature range is from 60 to 80?C, and the lower is from 30 to 60?C. The mass flow rates of dry air in the two stage desalination units are different. The pinch analysis chart is given. According to the pinch chart, the energy recover rate could get higher according to working temperature range. The research proves that the ...

2008-01-01

187

Thermodynamic properties of binary mixtures containing cycloalkanones; Excess volumes of cycloalkanones + cyclohexane, + benzene, and + tetrachloromethane  

Energy Technology Data Exchange (ETDEWEB)

Molar excess volumes have been determined by means of a vibrating-tube densimeter for binary liquid mixtures of cycloalkanones (cyclopentanone and cyclohexanone) + cyclohexane, + benzene, and + tetrachloromethane. The V/sup E/ data are reported over the complete mole fraction range at 288.15, 298.15, and 308.15{Kappa}. The obtained excess volumes are positive for mixtures of cyclopentanone with cyclohexane and are negative for mixtures of the cycloalkanones with benzene and tetrachloromethane; for the system cyclohexanone-cyclohexane the V/sup E/ values are positive for a wide range of mole fraction, but at very low cyclohexane mole fraction an inversion of the sign of V/sup E/ is observed. The data show that in the considered range of temperature the values of the temperature coefficient ({partial derivative}V/sup E//{partial derivative}T) are negative for mixtures of the cycloalkanones with benzene and are almost zero for mixtures with ...

1989-04-01

188

Thermalhydraulic Characteristics for Wolsung-1 after retubing  

International Nuclear Information System (INIS)

The ROP margin in a CANDU reactor is decreasing over time due to the Primary Heat-Transport System (PHTS) aging effect. Adjustment of the ROP trip setpoint is required to maintain a high trip-probability and ROP trip effectiveness. Especially, for Wolsong-1, which is scheduled to change the old pressure tubes in 2009, the trend of ROPT after the retubing should be reevaluated. Before setting a ROPT, the main thermal characteristics including Critical Channel Power (CCP) should be calculated by the NUCIRC code. In this paper, the thermalhydraulic evaluation for Wolsung-1 was conducted with the updated Wolsung-1 PHTS data. Specifically, for the case of 0 EFPY (Effective Full Power Year) and 11 EFPY after the retubing, the distribution of the channel flow rate, channel exit quality, critical channel power, and critical power ratio (CPR) of the Wolsong-1 aged plant are calculated

2009-05-01

189

Thermal performance simulation of a solar cavity receiver under windy conditions  

British Library Electronic Table of Contents (United Kingdom)

Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boi...

2011-01-01

190

The effects of various cooling strategies on surface roughness and tool wear during soft materials milling  

British Library Electronic Table of Contents (United Kingdom)

This work is focused on effect of various cooling strategies on surface roughness and tool wear during computer aided milling of soft workpiece materials. These milling operations were selected as dry milling, cool air cooling milling and fluid cooling milling. A cool air cooling system was designed and produced to cool end milling tools. Cool air was produced by a vortex tube. Annealed AISI 1050 was used as the workpiece material and cutting tool material was selected as HSS-Co8 DIN 844/BN. Optimal cutting parameters were selected according to workpiece hardness from reference catalog and kept for all tests. Tool wear and surface quality were measured for three different cooling types changing from ten minute machining time to thirty minute machining time. As a result, the surface roughne...

2009-01-01

191

Studies of basic parameters of electron-counting detection  

International Nuclear Information System (INIS)

Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).

1990-05-21

192

Structural material trends in future power plants  

Energy Technology Data Exchange (ETDEWEB)

Future power plants will be more fuel efficient, environmentally benign, and economical than current power plants. A high performance power system (HIPPS), based on a coal-fired combined cycle, is currently being developed. The corrosion and temperature-strength properties of currently available metallic materials limit the maximum efficiency of this cycle. Recently, ceramic matrix composites have shown promise in overcoming the design limitations on the future power plants. In particular, the high-temperature, and corrosion and erosion resistant properties of continuous fiber ceramic composites (CFCCs) will allow engineers to design high-temperature heat exchangers, cyclone vortex finder tubes, and other components. Research being performed to evaluate candidate materials for use in future power plants is discussed.

2000-07-01

193

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

194

Modelling of two-phase natural circulation in a WWER-plant: PMK experimental results  

International Nuclear Information System (INIS)

Experiments have been performed with the PMK integral-type facility, a model of WWER-440 type PWRs, to investigate two-phase natural circulation behaviour. The phenomena to be expected in this reactor type are different from those in PWRs with vertical steam generators mainly due to the loop seal in the hot leg and the horizontal layout of the steam generator heat transfer tubes. The experiments showed that the system is repressurized when the water level drops to the hot leg elevation due to the effect of the loop seal. Opening of the loop seal can be smooth, but may lead to oscillations depending on the power and the mass inventory. Natural circulation recovers after the hot leg loop seal is opened, but then decreases with further mass inventory decrease. (orig.).

195

Influence of sulfur dioxide content of 20% and 92% sulfuric acid on anodic behavior of stainless steels  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates steels 12Kh18N10T, 10Kh17N13M2T, 08Kh22N6T, and 08Kh21N6M2T. In corrosion of stainless steels in sulfuric acid solutions, dissolved sulfur dioxide acts as a cathodic depolarizer, capable of being reduced to elemental sulfur or forming sulfides with the metal. Depending on the conditions, this is associated with some increase in potential and greater or lesser increase in corrosion or facilitation of passivation of active steel. After passivation the influence of SO/sub 2/ is negligible. The results of this investigation were used as initial data for developing systems of anodic protection for shell-and-tube heat exchangers for sulfuric acid.

1986-07-01

196

High-power rf-pulsed modulators for the Los Alamos free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

In the rf-driven free-electron laser (FEL) at the Los Alamos National Laboratory, there are two pulsed-power rf modulators as sources for two tandem, side-coupled 20-MeV linear accelerators. The rf power used to control the cavity fields is supplied by two 5.5-MW modulating anode klystrons operating at a center frequency of 1300.2 MHz. The modulation of the 125 kV klystron is achieved by using a triode switch tube that provides a pulse width up to 300 ..mu..s and a pulse repetition rate up to 10 Hz. This paper describes the present configuration of these two duplicate systems and presents plans for meeting the requirements of future rf FEL experiments at Los Alamos. 12 refs., 5 figs.

1987-09-01

197

Genetic origin of Mesozoic natural gases in the Ordos Basin (China): Comparison of carbon and hydrogen isotopes and pyrolytic results  

British Library Electronic Table of Contents (United Kingdom)

Permian coal and Triassic mudstone from the Ordos Basin were pyrolyzed in a closed system using a gold tube technique. Carbon and hydrogen isotopes of the gases generated from pyrolysis were compared to Mesozoic gases in the basin to interpret the origin, maturity and any mixing of gases. Maturation trends for thermogenic methane from both coal and lacustrine kerogens in our experiment were found to be independent of heating rate, allowing their use for determination of gas provenance. Gases from a tectonically stable area like the Shanbei slope are derived mainly from Yanchang lacustrine kerogen, and gases in tectonically active areas consist of mixtures of coal-derived gases and oil-associated methane from deeply buried formations, as well as oil-associated gases and biogenic gases from ...

2010-01-01

198

Evaluation of HL 20 Roller Pump and Rotaflow Centrifugal Pump on Perfusion Quality and Gaseous Microemboli Delivery  

British Library Electronic Table of Contents (United Kingdom)

Abstract The purpose of this study was to compare the HL 20 roller pump (Jostra USA, Austin, TX, USA) and Rotaflow centrifugal pump (Jostra USA) on hemodynamic energy production and gaseous microemboli (GME) delivery in a simulated neonatal cardiopulmonary bypass (CPB) circuit under nonpulsatile perfusion. This study employed a simulated model of the pediatric CPB including a Jostra HL 20 heart lung machine (or a Rotaflow centrifugal pump), a Capiox BabyRX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Capiox pediatric arterial filter (Terumo Corporation), and inch tubing. The total volume of the experimental system was 700 mL (500 mL for the circuit and 200 mL for the pseudo neonatal patient). The hematocrit was maintained at 30% using human blood. At the beginning of each trial, a 5 ...

2010-01-01

199

Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging  

International Nuclear Information System (INIS)

This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.

1990-11-25

200

Basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

Energy Technology Data Exchange (ETDEWEB)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region.

1988-02-01

201

Anodic corrosion protection of sulphuric acid plants with regard to the recovery of heat  

Energy Technology Data Exchange (ETDEWEB)

Anodic protection makes it possible to keep materials which can be passivated in a 'passive' state or to bring them into this state, even in unfavourable conditions. With sulphuric acid concentrations of 93-99% this method permits the use of inexpensive, stainless austenitic steels, e.g. 1.4541 and 1.4591, at temperatures of up to 160/sup 0/C. The temperature range from 120/sup 0/C, in particular, is suitable for heat recovery. Anodic protection by the APR-system provides safe and low-cost protection for air coolers and bare tube coolers in sulphuric acid plants. The results of laboratory, pilot plant and commercial trials show that in this way a safe operation of sulphuric acid coolers is possible on a long-term basis.

1982-05-01

202

A basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

International Nuclear Information System (INIS)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region. (author).

1988-01-01

203

Study of the effect of noncondensable gas on heat transfer phenomena in horizontal steam generator of pactel facility with CATHARE2 V1.5a  

International Nuclear Information System (INIS)

Lappeenranta University of Technology (LTKK) and VTT Energy carried out a series of preliminary tests in 1999 to study the behavior of noncondensable (NC) gases in VVER geometry. The tests aimed at studying the effect of NC gases on system thermal-hydraulics and on heat transfer in a horizontal steam generator (HSG). The system behavior can be affected by hydrogen produced in the core in case of a severe accident, by nitrogen from hydro-accumulators released into the primary circuit in case of a loss-of-coolant accident (LOCA) and more generally by any NC gas in all cases where cooling is ensured by natural circulation. A secondary objective of the tests - the first series of tests ever performed with NC gas with PACTEL - was to find out, if the instrumentation of PACTEL was adequate for this type of tests and if it was functioning properly. This paper presents the measured and calculated (CATHARE code version V15a mod 2.1) results of the test ...

2001-03-20

204

Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows  

Energy Technology Data Exchange (ETDEWEB)

Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture interphase is accounted for by using the stagnant film model, ...

1995-01-01

205

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

Energy Technology Data Exchange (ETDEWEB)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular tube. Based on the ...

1995-03-01

206

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

International Nuclear Information System (INIS)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular tube. Based on the ...

207

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron ...

1994-09-01

208

Development and validation of steam generator models for thermal performance monitoring  

International Nuclear Information System (INIS)

The thermal performance monitoring and optimization system TEMPO is developed at the OECD Halden Reactor Project. The system supports staff of nuclear power plants in identification and correction of problems, which cause small decreases in plant efficiency but which may lead to significant economical losses. The system-wide physical model consists of mathematical description of individual components, such as the reactor, the pumps, the heat exchangers, or the turbines, etc. TEMPO code has recently been extended with new steam generator (SG) models. The present paper summarizes the thermal-hydraulic modelling aspects of the vertical and the horizontal SG. The heat balance equations and their solution are shown with the appropriate initial and boundary conditions. The method of the calculation of the pressure losses are also introduced. The vertical SG model is based on a U-tube structure and treated as ...

2003-04-20

209

Operating experience with Alloy 800 SG tubing in Europe  

Energy Technology Data Exchange (ETDEWEB)

'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. ...

2007-07-01

210

Operating experience with Alloy 800 SG tubing in Europe  

International Nuclear Information System (INIS)

'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. These indications ...

2007-08-19

211

Flow induced vibration mock-up test for heat exchanger tubes of PWR steam generator  

International Nuclear Information System (INIS)

It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected ...

2000-10-01

212

Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition  

International Nuclear Information System (INIS)

In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse flow agrees very well ...

2008-12-01

213

Thermal hydraulic test for core cooling system using steam generators  

Energy Technology Data Exchange (ETDEWEB)

As a candidate of the new concept safety system for the next generation PWR in Japan, the hybrid safety systems, which are combination of the active and the passive safety systems, and passive core cooling system by natural circulation in the reactor coolant loop with horizontal-type steam generators during Loss of Coolant Accidents (LOCAs) are investigated. The passive safety systems are advanced accumulators (ACC), primary-side and secondary-side automatic-depressurization systems (ADS, SADS), and a gravity-driven safety injection system (GDI). The horizontal steam generator design avoids a siphon break caused from the accumulation of non-condensable gases in the tubes by using a vent line in the channel head of the steam generators. This study investigates the passive core cooling characteristics of horizontal-type ...

1999-07-01

214

Vacuum leak problem in low energy of pelletron  

International Nuclear Information System (INIS)

During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)

215

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979  

International Nuclear Information System (INIS)

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).

1994-10-18

216

Research on corrosion resistance of steam generator tube  

International Nuclear Information System (INIS)

In order to improve the reliability of PWR steam generators, we have performed research to improve the tubing material and tube-support-plate configuration, based on our wide operating experience, and have developed and verified Alloy TT690 as the optimum tubing material and the BEC (Broached Egg Crate) type tube-support design. In the research, we have studied the metallurgical mechanism of the alloy to improve its corrosion resistance, evaluated corrosion susceptible region quantitatively, estimated the actual environment in a steam generator and confirmed the reliability by a model boiler test over a long period. It has been verified that the steam generator with the latest design has higher reliability with respect to the corrosion resistance of tubes. (author).

217

Preparation of reactor tube by welding a porous membrane with a non-porous ceramic tube  

Energy Technology Data Exchange (ETDEWEB)

In the course of designing a catalytic porous membrane reactor for experimental studies, both inside and outside of the non-reaction zones as well as the two ends of the membrane need to be completely sealed to ensure that there is no flow across the membrane in the non-reaction zone. Experiments show that up to 50% of the total flow across the membrane may be contributed by the axial flow along the wall of the non-reaction zones if only one side of the membrane is sealed. Another problem that cannot be solved by sealing is the capillary flow of the catalyst along the tube wall into the non-reaction zones when the catalyst is doped on the membrane. One of the best ways to avoid this axial flow of catalyst would be to use non-porous tubes in the non-reaction zones and join them with the porous membrane tube. In doing so, the cost of the membrane reactor could be reduced simply because shorter membrane ...

1994-12-31

218

Numerical simulation of fluid flow and heat transfer in a concentric tube heat exchanger  

International Nuclear Information System (INIS)

In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. The difficulties associated with the simulation of a heat exchanger augmented with ...

2003-05-28

219

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

Energy Technology Data Exchange (ETDEWEB)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-01-01

220

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

International Nuclear Information System (INIS)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-03-09

221

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being ...

2001-07-01

222

Rack and pinion based fuelling machine of 540 MWe PHWR-from concept to refuelling  

International Nuclear Information System (INIS)

On-power refuelling is an integral feature of PHWR units. The most notable aspect of refuelling system of 540 MWe PHWR (TAPP-3 and 4) is that the FM Head is based on rack and pinion mechanism for B-ram and C-ram of Ram assembly. Latch ram used during plug operations, is assembled in between B-ram and C-ram and is moved by a ballscrew driven by oil hydraulic motors. This unique design has been employed for the first time in a PHWR unit. In comparison, B-ram is ballscrew driven and C-ram is moved by heavy water hydraulic force in FM Heads of 220 MWe PHWR units. Over the years, a number of design improvements have been carried out in the 220 MWe Fuelling Machines to meet the challenge of increasing demands of higher refuelling rates. However, in 540 MWe unit, the average refuelling rate for an equilibrium core is nearly twice that of 220 MWe units. Apart from other assemblies in FM Head, the performance of Ram assembly plays a key role in meeting this demand. The ...

2006-11-13

223

Safety analysis program for steam generators replacement and power uprate at Tihange 2 nuclear power plant  

International Nuclear Information System (INIS)

The Belgian Tihange 2 nuclear power plant went into commercial operation in 1983 producing a thermal power of 2785 MW. Since the commissioning of the plant the steam generators U-tubes have been affected by primary stress corrosion cracking. In order to avoid further degradation of the performance and an increase in repair costs, Electrabel, the owner of the plant, decided in 1997 to replace the 3 steam generators. This decision was supported by the feasibility study performed by Tractebel Energy Engineering which demonstrated that an increase of 10% of the initial power together with a fuel cycle length of 18 months was achieved. Tractebel Energy Engineering was entrusted by Electrabel as the owner's engineer to manage the project. This paper presents the role of Tractebel Energy Engineering in this project and the safety analysis program necessary to justify the new operation point and the fuel cycle extension to 18 months re-analysis of FSAR chapter 15 accidents ...

2002-08-11

224

Irradiation characteristics examination technology development of irradiated nuclear material and high burn-up fuels  

Energy Technology Data Exchange (ETDEWEB)

The research and development for the first year of the project are performed through specialization of researchers, information from aborad and international cooperation, securement of advanced nuclear technology, development and installation of test equipment, application of external man-power, establishment of advanced test techniques, and certified test method. 1. Absolute efficiency measurement examination technology development of gamma scanning system 2. Sample preparation technology development of SEM and EPMA for micro-structural observation and chemical composition analysis 3. Irradiated high burn-up nuclear fuel transportation and test for PWR 4. Development of hot cell examination techniques and equipment 5. Acquirement of KOLAS system. In addition to the project, the following activities are carried out as follows; - PIE of Hanaro fuel(KH99H-001) - PIE of U-Mo advanced nuclear fuel irradiated at Hanaro - PIE of Hi-MET advanced ...

2002-12-01

225

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the ...

2007-01-01

226

Hydrogen synthesis via combustion of fuel-rich natural gas/air mixtures at elevated pressure  

Energy Technology Data Exchange (ETDEWEB)

Combustion of extremely fuel-rich ({phi}=4) methane/air mixtures at elevated pressures is investigated as a potential means to generate molecular hydrogen by non-catalytic partial oxidation. This system is investigated both computationally and experimentally. The computations use a perfectly-stirred reactor model and an explicit methane cool-flame mechanism to investigate the effects of reactor parameters on reaction time and product composition. Under adiabatic conditions, such mixtures are predicted to autoignite at low temperatures {approx}700 K for pressures exceeding 8.5 atm. Above 15 atm, conversion to products is complete in roughly 1 s. The dependence of reaction time and hydrogen yield is investigated as a function of inlet temperature, system pressure, and flame equivalence ratio. Actual product yields are measured in a tube reactor facility, and many of the predictions of the model, including long relaxation ...

2005-07-01

227

Effects of oxygen, copper and acid chlorides on denting corrosion  

Energy Technology Data Exchange (ETDEWEB)

The effect of dissolved oxygen and copper on denting corrosion at 280/sup 0/C in solutions of NaCl at pH 9 with ammonia was investigated using a packed tube/support plate crevice in a laboratory simulation. The onset of corrosion was detected with a hydrogen analyzer sensitive to 0.2 ppB. In the absence of copper, rapidly rising hydrogen concentrations were detected only when the product of the chloride and oxygen concentrations were detected only when the product of the chloride and oxygen concentrations in the boiler-water exceeded 25 (ppM)/sup 2/, but at these high concentrations, unheated low-carbon steel surfaces in the system were as sensitive to corrosion as the heated crevice. When copper metal was present in the feed system, corrosion of the heated crevice occurred in the absence of oxygen, provided the copper had previously been exposed to dissolved oxygen. Dosing hydrazine into the feedwater eventually suppressed ...

1986-07-01

228

Core Heat Transfer Model Validation of the TASS/SMR-S Code using the Bennett's Test  

International Nuclear Information System (INIS)

The SMART (System-integrated Modular Advanced ReacTor) which is a 330 MWt advanced integral PWR was developed by the KAERI (Korea Atomic Energy Institute) for electricity generation and seawater desalination. A thermal hydraulic evaluation and analysis of the SMART is performed by the TASS /SMR-S (Transient And Setpoint Simulation/System integrated Modular Reactor-Safety). The TASS/SMR-S code has various models reflecting the design features of the SMART such as the drift flux model, the core models (core power and core heat transfer model), the component models, and the specific models. One of the core models is the core heat transfer model. The role of this model is to calculate the heat flux and radial temperature profiles at a fuel rod surface using the relevant heat transfer correlations for all of the heat transfer modes. Also it is modeled to meet the requirements of the 10 CFR 50 appendix K EM model for the CHF (Critical Heat Flux) and ...

2010-10-01

229

Assessing the Significance of Above- and Belowground Carbon Allocation of Fast- and Slow-Growing Families of Loblolly Pine - Final Report  

Energy Technology Data Exchange (ETDEWEB)

During this project we experimentally evaluated the below-ground biomass and carbon allocation and partitioning of four different fast- and slow-growing families of loblolly pine located in Scotland County, NC, in an effort to increase the long-term performance of the crop. The trees were subjected to optimal nutrition and control since planting in 1993. Destructive harvests in 1998 and 2000 were used for whole?plant biomass estimates and to identify possible family differences in carbon acquisition (photosynthesis) and water use efficiency. At regular intervals throughout each year we sampled tissues for carbohydrate analyses to assess differences in whole-tree carbon storage. Mini rhizotron observation tubes were installed to monitor root system production and turnover. Stable isotope analysis was used to examine possible functional differences in water and nutrient acquisition of root systems between the various ...

2001-03-01

230

A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath  

International Nuclear Information System (INIS)

The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer process. A physical ...

1985-10-01

231

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

British Library Electronic Table of Contents (United Kingdom)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-01-01

232

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

Science.gov (United States)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-12-01

233

Terminated Exploding Wire Energy Source.  

Science.gov (United States)

By placing a discharge or 'dump' tube across an exploding bridgewire load, it is possible to by-pass the electrical energy and terminate the explosion of the wire. The dump tube is triggered by a signal derived from the energy removed from the storage cap...

1965-01-01

234

Stability of Plasma Human Immunodeficiency Virus Load in VACUTAINER PPT Plasma Preparation Tubes during Overnight Shipment  

UK PubMed Central (United Kingdom)

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas...Full Text Available

2000-01-01

235

Social media - Social media, The University of York  

Wastenet

...A directory of University social media accounts, including Facebook, Twitter and YouTube facebook, twitter, blog Social media - Social media, The ... Key: Facebook, Twitter, YouTube, Blog, LinkedIn, Flickr Missed you out? If you'd like to be included on this ...

236

Safety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal...Full Text Available

237

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. ...

1979-01-01

238

Mechanistic insights from a quantitative analysis of pollen tube guidance  

UK PubMed Central (United Kingdom)

BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available

239

Material and process improvements in condenser tubing  

Energy Technology Data Exchange (ETDEWEB)

The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process ...

2010-07-01

240

Lectin Binding of the Major Polar Tube Protein (PTP1) and its Role in Invasion  

Science.gov (United States)

... 2003)050[0600:LBOTMP]2.0.CO;2 Lectin Binding of the Major Polar Tube Protein (PTP1) ... PTP1. We, therefore, undertook a study ...

241

Intergranular attack or corrosion in a once-through model steam generator: Final report  

Energy Technology Data Exchange (ETDEWEB)

Faulting the feedwater for a 19-tube, model steam generator with 10 ppM of caustic once a week produced widespread shallow 25 to 75 micrometers (1 to 3 mils) intergranular attack (IGA) on alloy 600 tubes and an axial tube rupture at the steam-water interface after 4.8 years. An extensive investigation of the IGA damage found little correlation with major test variables beyond the indication that mill-annealed tubing was more susceptible to attack than stress-relieved tubing. The most likely cause of the tube rupture was caustic that concentrated to high levels in a porous scale on the tube at the liquid-vapor interface where there was a high available superheat. Nondestructive examination (NDE) eddy current probes underestimated the depth of IGA and were not sensitive to circumferential cracks less than 152 micrometers (6 mils) deep that ...

1987-07-01

242

Integrity of the tubes used in vertical and horizontal steam generators  

British Library Electronic Table of Contents (United Kingdom)

Statistical data on experience gained from operation of steam generators around the world are presented, problems arising in vertical and horizontal steam generators are described, and the conditions of heattransfer tubes used in them are compared.

2011-01-01

243

Heat transfer augmentation in 3D internally finned and microfinned helical tube  

Energy Technology Data Exchange (ETDEWEB)

Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in ...

2005-05-01

244

Enhanced tube inner surface heat transfer device and method  

Science.gov (United States)

An inner surface substrate of metal tubes is provided with a single layer of randomly distributed metal bodies bonded to the substrate, spaced from each other, and substantially surrounded by the substrate to form body void space.

1979-05-15

245

Endoscopic T-tube placement in the management of lye-induced esophageal perforation: Case report of a safe treatment strategy  

UK PubMed Central (United Kingdom)

Esophageal perforation is associated with a significant risk of morbidity and mortality. We report herein a case of lye-induced esophageal perforation managed successfully by employing endoscopic T-tube...Full Text Available

246

Conjugate heat transfer of a finned tube. Part B: Heat transfer augmentation and avoidance of heat transfer reversal by longitudinal vortex generators  

Energy Technology Data Exchange (ETDEWEB)

Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the ...

1995-08-01

247

An argument for the conservative management of small traumatic pneumathoraces in populations with high prevalence of HIV and tuberculosis: an evidence-based review of the literature  

UK PubMed Central (United Kingdom)

BackgroundTraumatic pneumothoraces are common. Many are managed with tube thoracostomy. However, there is a high complication rate from chest tube placement, particularly in patients...Full Text Available

248

Substantiation of recommendations for ensuring the design service life of heat-transfer tubes used in a PGV-1000MKP steam generator  

Science.gov (United States)

We present the results obtained from tests and studies carried out on the model of tube bundles for a PGV-1000 horizontal steam generator that were conducted for experimentally substantiating the design service life of a steam generator tube bundle intended for use at new nuclear power stations equipped with a PGV-1000MKP steam generator. Measures taken to minimize the incipience and development of local corrosion damage to the heat-transfer tubes and ensure their design service life are substantiated and confirmed.

2011-03-01

249

Peripherally inserted central catheter  

Science.gov (United States)

You have a peripherally inserted central catheter (PICC). This is a tube that goes into a vein in your arm. It will help carry nutrients ...

250

Meteorological Measurement Guide  

Science.gov (United States)

... 2-22 Page 31. The mercury barometer operates on the principle of air pressure forcing the mercury column up an evacuated tube. ...

1992-01-01

251

Kinetics of salt concentration in heated crevices  

International Nuclear Information System (INIS)

In PWR steam-generators, the crevice between tube and tube-support plate tends to fill with porous deposits during operation and acts as a concentration site for chemicals in the boiler water, which may lead to corrosion of the tube and tube-support-plate. The rate of concentration, the magnitude of the concentration factor and the rate of release of solute when conditions change are important parameters for devising strategies to minimize corrosion. Values of these parameters for salt concentration have therefore been measured in a laboratory simulation of the crevice and are used to formulate a model of the concentrating process.

1985-03-01

252

Is OD peening of Alloy 800 SG tubes desirable?  

Energy Technology Data Exchange (ETDEWEB)

The shot peening of the outer surface of Alloy 800 is proposed by the steam generator supplier in order to increase the stress corrosion cracking resistance of the tubes. The benefits and drawbacks of such a treatment are evaluated, focusing on the main concern i.e. a possible enhanced tendency of stress corrosion cracking at the transition of the expanded tube-to-tubesheet joint. Stress corrosion tests as well as residual stresses measurements demonstrate no significant difference between peened and unpeened tubes at that location. The other concerns such as stability of the compressive stresses, increased risk of pitting or intergranular attack and pollution of the secondary circuit by fragmented beads appear the as minor concerns.

1992-12-31

253
254

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

255

Heat exchanger tube vibration: comparison between operating experiences and vibration analyses  

International Nuclear Information System (INIS)

Tube failures due to excessive flow-induced vibration must be avoided to assure the reliable performance of heat exchangers. Such components must be thoroughly analysed for vibration at the design stage. Several flow-induced vibration mechanisms are possible. In this paper, particular attention is given to fluidelastic instability of tube bundles subjected to liquid and two-phase cross-flow. The performance of ten operating heat exchanger components is reviewed to validate our recommended vibration analysis guidelines. Both tube failure histories and satisfactory performances are considered. The results show that a fluidelastic instability constant K=3.3 is a reasonable design criterion. (auth).

1992-12-01

257

Explosive Performance Modification by Cosolidification of ...  

Science.gov (United States)

... A booster pellet, normally Comp B, was placed in the tube and an exploding bridgewire (EBW) detonator in a plastic holder was glued in with a ...

1976-10-01

259

Dictionary of Technical Terms for Aerospace Use - S  

Science.gov (United States)

sabot: A device fitted around or in back of a projectile in a gun barrel or launching tube to support or protect the projectile or to prevent the escape of ...

260

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

261

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

262

A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants  

International Nuclear Information System (INIS)

In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.

1993-11-01

263

Transmit-receive eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).

1987-09-01

264

Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976  

International Nuclear Information System (INIS)

A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).

1994-10-18

265

Solar collectors with tubes partially filled with porous substrates  

Energy Technology Data Exchange (ETDEWEB)

In this work, the thermal performance of a conventional collector is improved by inserting porous substrates at the inner walls of the collector tubes. The porous substrates improve the convective heat transfer coefficient between the tube wall and the fluid. This improvement is investigated numerically and its effects on the efficiency and the useful gain of the collector are evaluated. It is found that inserting the porous substrate may raise the collector efficiency considerably, especially at high values of the overall heat loss coefficient.

1999-02-01

266

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

Energy Technology Data Exchange (ETDEWEB)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...

2005-07-01

267

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

International Nuclear Information System (INIS)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...

2005-10-27

268

Characterization of tube support alloys  

International Nuclear Information System (INIS)

The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions.

1985-03-01

269

Characterization of eddy current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.

1985-02-01

270

Characterization of Eddy Current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.

1985-02-01

271

Centering device  

Energy Technology Data Exchange (ETDEWEB)

A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.

1980-03-15

272

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural ...

273

Transmit-receive eddy current probes  

International Nuclear Information System (INIS)

In the last two decades, due to increased inspection demands, eddy current instrumentation has advanced from single-frequency, single-output instruments to multifrequency, computer-aided systems. This has significantly increased the scope of eddy current testing, but, unfortunately, it has also increased the cost and complexity of inspections. In addition, this approach has not always improved defect detectability or signal-to-noise. Most eddy current testing applications are still performed with impedance probes, which have well known limitations. However, recent research at AECL has led to improved eddy current inspections through the design and development of transmit-receive (T/R) probes. T/R eddy current probes, with laterally displaced transmit and receive coils, present a number of advantages over impedance probes. They have improved signal-to-noise ratio in the presence of variable lift-off compared to impedance probes. They have strong directional ...

1997-10-27

274

Thermal energy storage performance of fatty acids as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

Thermal energy storage performance of fatty acids and a eutectic mixture as phase change materials (PCMs) has been investigated experimentally. The selected PCMs for this study were palmitic acid, myristic acid, stearic acid, and a mixture of stearic and myristic acids in eutectic combination ratio of 65.7 wt% myristic acid and 34.3 wt% stearic acid. The PCMs have a melting temperature range of 50.0{sup o}C to 61.20{sup o}C and a latent heat range of 162.0 J/g to 204.5 J/g. The inlet temperature and the mass flow rate of heat transfer fluid (HTF) were selected as experimental parameters to test the thermal energy storage performance of the PCMs. The transition times, temperature range, propagation of the solid-liquid interface, as well as heat flow rate characteristics of the employed cylindrical tube storage system were studied at varied experimental parameters. The experimental results show that the melting front moves to inward in the radial ...

2006-01-21

275

The off-gas cleaning system for gases formed during the vitrification of high-activity wastes from the nuclear power plant A 1  

International Nuclear Information System (INIS)

A multielement apparatus for the removal of aerosols formed in the vitrification of simulated high-activity accident wastes from the decommissioned nuclear power plant A-1 has been designed, manufactured and tested. The apparatus consists of two cooling and condensing steps connected in series, and of five filtration steps also connected in series. The five filtration steps allowed to achieve a decontamination factor of 1x10"5 in the case of removal of a NaCl("2"4Na) testing model aerosol. The decontamination factor for removal of the cesium aerosol by the whole apparatus was 3.3x10"6. In the first filtration step the aerosols are removed by the cartridge with a filtration fabric made of polyethylene fibers, in the second step by the cartridge with a granulated natural material, in the third step by the cartridge with glass-fiber filtration paper, in the fourth and fifth steps by the cartridge with high-efficiency filtration paper made of glass microfibers. In the ...

276

Study on bubbly flow behavior in natural circulation reactor by thermal-hydraulic simulation tests with SF6-Gas and ethanol liquid  

Science.gov (United States)

An advanced experimental technique has been developed to simulate two-phase flow behavior in a light water reactor (LWR). The technique applies three kinds of methods; (1) use of sulfur-hexafluoride (SF6) gas and ethanol (C2H5OH) liquid at atmospheric temperature and a pressure less than 1.0MPa, where the fluid properties are similar to steam-water ones in the LWR, (2) generation of bubble with a sintering tube, which simulates bubble generation on heated surface in the LWR, (3) measurement of detailed bubble distribution data with a bi-optical probe (BOP), (4) and measurement of liquid velocities with the tracer liquid. This experimental technique provides easy visualization of flows by using a large scale experimental apparatus, which gives three-dimensional flows, and measurement of detailed spatial distributions of two-phase flow. With this technique, we have carried out experiments simulating two-phase flow behavior in a single-channel geometry, a ...

2009-02-01

277

SGTR Project: Separate Effect Studies for Vertical Steam Generators  

Energy Technology Data Exchange (ETDEWEB)

The SGTR project has been carried out within the fifth EURATOM Framework Programme (Contract No FIKS-CT-1999-0007). Its main objective was to provide an experimental database and to develop and/or verify models to support definition of accident management measures in the hypothetical case of a Steam Generator tube Rupture (SGTR) sequence. The project addressed both vertical and horizontal steam generator designs. This report summarises the main results obtained in the intermediate scale experimentation that addressed Western type steam generators. The specific goal of this test programme was to investigate aerosol retention in the break stage of the secondary side of a water-empty steam generator. The test matrix consisted of 12 tests that explored the influence of variables such as break type and orientation and inlet gas flow rate. This work was performed in the PECA facility of the Laboratory for Analysis of Safety Systems (LASS). Aerosol ...

2003-07-01

278

PFB coal fired combined cycle development program. Annual report, July 1978-June 1979  

Energy Technology Data Exchange (ETDEWEB)

The Coal Fired Combined Cycle (CFCC) is the unique powerplant concept developed under the leadership of the General Electric Company to provide a direct coal-burning gas turbine and steam turbine combined cycle powerplant. On the basis of previous studies and confirming work under this contract, General Electric continues to believe that the CFCC approach offers important advantages over alternate approaches: higher powerplant efficiency in the combustor temperature range of interest; reduced combustor/steam generator corrosion potential, due to low fluid-bed tube temperature (as contrasted to the air in tube cycle); and increased gas turbine bucket life from improved material protection systems. The objective of this program is to evaluate the coal fired combined cycle powerplant conceptual design, and to conduct a supporting development program. The supporting development is required for evaluating the pressurized ...

1980-05-01

279

Ecological sanitation: and sustainable sanitation system especially for poor and lowland countries  

International Nuclear Information System (INIS)

More than 80% of the people of Nepal are farmers and 90% of the farmers do farming for subsistence. Agricultural productions contribute about 50% of country's GDP. Agricultural sector has been categorized as the top priority sector since many years. The environment of the country has also deteriorated substantially by the unplanned and unscientific use of natural resources such as air, soil, water, air and forest. Fertility of the soil has also been declining and studies show that productions in mountains is decreasing at a rate of 40 Kg/ha. Yr (1). The Terai, a narrow strip of land in the south, is in heavy pressure due to over exploitation and population growth (both natural and migratory). Shallow groundwater (shallow tube wells) is the main source of drinking water in Terai (the lowland region of Nepal). A study conducted by Department of Water Supply and Sewerage (DWSS) showed that more than 55% of Terai tube wells are microbiologically ...

2004-06-07

280

Torsional responses of double-walled carbon nanotubes via molecular dynamics simulations  

Energy Technology Data Exchange (ETDEWEB)

The buckling behaviors of double-walled carbon nanotubes (DWCNTs) under torsion are investigated by using molecular dynamics (MD) simulations. The effect of length on the torsional buckling behaviors of DWCNTs is examined for the first time. The simulation results show that the DWCNTs experience gradual or simultaneous buckling deformations depending on their lengths. In addition, the effect of the inner tube in a DWCNT on its torsional buckling behavior is also examined. The presence of the inner tube triggers van der Waals (vdW) interactions between it and the outer tube and thus leads to a stiffening effect of the DWCNT against torsional deformation. Whether the ends of the inner tube are free or fixed and whether it is subject to a torque or not, the critical torque and the critical torsional angle of the outer tube are only marginally affected.

2008-11-12

281

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-15

282

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-01

283

Superphenix 1 steam generator fabrication  

Energy Technology Data Exchange (ETDEWEB)

The Superphenix 750-MW (thermal), once-throughtype steam generators are the result of over 10 years of intensive research and development. Detailed design and manufacture of the components lasted from 1977 to 1982. The main difficulties encountered during the construction of these prototype units concerned: demonstration of satisfactory high-temperature properties of Alloy 800 tubes; proven resistance of tube welds to thermal fatigue and of structures and shells to sodium/ water reaction effects; prevention of the tube bundle to flow-induced vibration; necessity of manual welding of shells to prevent hot cracking hazards related to the boron content of the steel; and welding of heat exchange tubes. None of these difficulties, however, invalidated initial major design choices, but provided a wealth of technical and technological experience and knowledge for the steam generators of the future. Plans for ...

1985-02-01

284

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)

2010-09-01

285

Investigations on denting phenomenon in monel tubes  

International Nuclear Information System (INIS)

Denting phenomenon as experienced in PWR steam generators has been investigated in the laboratory of Monel-400 tubes and C-steel baffles combination. Isothermal corrosion tests have been carried out by exposing capsules, containing a crevice between Monel-400 tubes and C-steel plugs, in plausible corrodents at 300"0C. Results indicated that the denting phenomenon is strongly influenced by the chloride content in the solution. In addition, it is a time dependent process. Stress exerted on the tubes by the growth of corrosion product on the outside surface of C-steel plugs are enough to deform the Monel tubes. The results have been discussed on the basis of accelerated corrosion of C-steel by hydrolyzable metal chlorides. (author).

1981-05-01

286

Evaluation, testing and database generation of pitting corrosion characteristics of domestic steam generator tubing material  

Energy Technology Data Exchange (ETDEWEB)

Accumulation of Chloride and Cupric ions under the sludge on the steam generator tubing surface in the area between tube sheet and the first tube support is known to be the main reason for the pitting corrosion. In addition to those ions, oxygen, pH, temperature, heat treatment history, contests of minor elements such as C, S or Ti in the alloy are also influencing the material's the pitting corrosion resistance. a series of autoclave pitting test was conducted to evaluate the pitting corrosion characteristics of the domestically produced alloy 690 tubing material and compare with that of INCO manufactured material. 16 refs., 44 figs., 5 tabs. (Author)

1998-04-01

287

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-07-01

288

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-06-01

289

Top of tubesheet cracking in Bruce A NGS steam generator tubing - recent experience  

Energy Technology Data Exchange (ETDEWEB)

During the Bruce A Nuclear Generating Station (BNGS-A) Unit 1 1997 planned outage, a dew point search method identified a leak in one steam generator(SG) tube. Subsequently, the tube was inspected with all available eddy current probes and removed for examination. The initial inspection results and metallurgical examination of the removed tube confirmed that the leak was due to intergranular attack/stress corrosion cracking (IGA/SCC) emanating from the secondary side of the tube at the top of the tubesheet location. Subsequently, eddy current and ultrasonic indications were found at the top of the tubesheet of other Alloy 600 SG tubes. To investigate the source of the indications and to validate the inspection probes, sections of 40 tubes with various levels of damage were removed. The metallurgical examination of the removed sections showed that both secondary ...

1998-07-01

290

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...

2005-07-01

291

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

International Nuclear Information System (INIS)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...

2005-10-27

292

CFD simulation of steam generator tube rupture thermal-hydraulics  

Energy Technology Data Exchange (ETDEWEB)

Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and ...

2004-07-01

293

A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP  

International Nuclear Information System (INIS)

Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. ...

2010-10-01

294

Failure analysis report: Heat exchanger tubes geothermal binary power plant, Magma Electric Company, East Mesa, California  

Energy Technology Data Exchange (ETDEWEB)

Radian received twelve sections of heat exchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heat exchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heat exchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heat exchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.

1982-05-01

295

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present ...

2011-01-15

296

Volumetric properties of dichloromethane with aniline or nitrobenzene at different temperatures: A theoretical and experimental study  

Energy Technology Data Exchange (ETDEWEB)

The densities for binary mixtures of dichloromethane with aniline, or nitrobenzene, respectively, including those of pure liquids, were measured over the entire composition range at T = (288.15, 293.15, 298.15, and 303.15) K and atmospheric pressure using a vibrating-tube densimeter. From the experimental results, the excess molar volumes, V{sub m}{sup E}, partial molar volumes, V{sub i}-bar, the apparent molar volume, V{sub {phi}}{sub i}, and the partial molar excess volumes at infinite dilution, (V{sub i}{sup E}-bar){sup {infinity}}, were calculated over whole composition range. Negative values of V{sub m}{sup E} for (dichloromethane + aniline) attributed to the formation of the charge transfer complex, while for (dichloromethane + nitrobenzene) system, the free volume effect played a dominant role. The extent of negative deviations in V{sub m}{sup E} values follows the order: nitrobenzene > aniline. The Prigogine-Flory-Patterson (PFP) ...

2009-03-15

297

Results of the Virgo central interferometer commissioning  

International Nuclear Information System (INIS)

The interferometric gravitational wave detector Virgo has successfully completed the first major step of its commissioning. It consists of a Michelson interferometer with 6 m arms with suspended mirrors. The interferometer is tuned to the dark fringe with a recycling mirror on the other port (bright fringe) to form an equivalent 12 m long Fabry-Perot cavity. This setup has allowed us to validate the major technology choices that have been made: passive seismic attenuators, a light source with a long mode cleaner, many analogue and digital servo loops, control software, high speed data acquisition system. A sensitivity of 8 x 10"-"1"7 m Hz"-"1"/"2 at 1 kHz together with a duty cycle of 80% has been attained during a 72 h engineering run. The data analysis allowed us to understand the noise contributions, and several improvements have been carried out while proceeding with the end of the installation of vacuum tubes and the remaining suspensions, ...

2004-03-07

298

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...

2008-06-01

299

Optimized, Competitive Supercritical-CO_2 Cycle GFR for Gen IV Service  

International Nuclear Information System (INIS)

An overall plant design was developed for a gas-cooled fast reactor employing a direct supercritical Brayton power conversion system. The most important findings were that (1) the concept could be capital-cost competitive, but startup fuel cycle costs are penalized by the low core power density, specified in large part to satisfy the goal of significant post-accident passive natural convection cooling; (2) active decay heat removal is preferable as the first line of defense, with passive performance in a backup role; (3) an innovative tube-in-duct fuel assembly, vented to the primary coolant, appears to be practicable; and (4) use of the S-Co2 GFR to support hydrogen production is a synergistic application, since sufficient energy can be recuperated from the product H2 and 02 to allow the electrolysis cell to run 250 C hotter than the reactor coolant, and the water boilers can be used for reactor decay heat removal. Increasing core power ...

300

Nuclear incident monitor criticality alarm instrument for the Savannah River Site: Technical manual  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site is a Department of Energy facility. The facility stores, processes, and works with fissionable material at a number of locations. Technical standards and US Department of Energy orders, require these locations to be monitored by criticality alarm systems under certain circumstances. The Savannah River Site calls such instruments Nuclear Incident Monitors or NIMs. The Sole purpose of the Nuclear Incident Monitor is to provide an immediate evacuation signal in the case of an accidental criticality in order to minimize personnel exposure to radiation. The new unit is the third generation Nuclear Incident Monitor at the Savannah River Site. The second generation unit was developed in 1979. It was designed to eliminate vacuum-tube circuits, and was the first solid state NIM at SRS. The major design objectives of the second generation NIM were to improve reliability and reduce maintenance costs. Ten prototype units have been ...

1996-05-21

301

Metal cation inhibitors for controlling denting corrosion in steam generators. Final report. [PWR  

Science.gov (United States)

Metal cations of arsenic, antimony, tin, manganese, zinc, cadmium, indium, and thallium have been evaluated in a preliminary way as possible3 inhibitors for controlling denting corrision observed in steam generators used with pressurized water reactors (PWR). The rationale for this approach was based upon the well-known inhibition effects of metal cations on corrosion rates in electrolyte/metal systems. A review of corrosion inhibition by metal cations (H. Leidheiser, Jr., Corrosion 36, 339 (1982)) has identified eleven inhibition mechanisms. The major test methods used for this evaluation were: (1) Isothermal capsule tests of carbon/steel/Inconel 600 tube bulging rates at temperatures up to 288/sup 0/C in seawater/copper-nickel chloride bulge-accelerating solutions. (2) Immersion weight-loss tests of steel coupled to Inconel 600 in boiling (102/sup 0/C) 3% sodium chloride solutions. In addition, electrochemical measuremens and surface analyses ...

1982-12-01

302

Law project adopted by the Senate and authorizing the ratification of the additional protocol to the agreement between France, the European atomic energy community and the international atomic energy agency relative to the application of warranties in France; Projet de loi adopte par le Senat autorisant la ratification du protocole additionnel a l'accord entre la France, la Communaute europeenne de l'energie atomique et l'Agence internationale de l'energie atomique relatif a l'application de garanties en Franc  

Energy Technology Data Exchange (ETDEWEB)

This project of law concerns an additional protocol to the agreement of warranties signed on September 22, 1998 between France, the European atomic energy community and the IAEA. This agreement concerns the declaration of all information relative to the R and D activities linked with the fuel cycle and involving the cooperation with a foreign country non endowed with nuclear weapons. These information include the trade and processing of nuclear and non-nuclear materials and equipments devoted to nuclear reactors (pressure vessels, fuel loading/unloading systems, control rods, force and zirconium tubes, primary coolant pumps, deuterium and heavy water, nuclear-grade graphite), to fuel reprocessing plants, to isotope separation plants (gaseous diffusion, laser enrichment, plasma separation, electromagnetic enrichment), to heavy water and deuterium production plants, and to uranium conversion plants. (J.S.)

2002-10-01

303

Increasing the operational safety of nuclear facilities by using special insulation parts in the containment zone  

International Nuclear Information System (INIS)

LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, form and function to the original products. Additional tests have also proven higher application ranges ...

2005-06-15

304

Improvement of FCR-linear tomography using digital image processing  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image ...

1994-02-01

305

Horizontal liquid film mist two-phase flow, 2. Droplet deposition and entrainment rates  

Energy Technology Data Exchange (ETDEWEB)

In the region of annular liquid film-mist flow, the behavior of the droplets formed from the liquid film and the rate of formation are the subjects to be clarified in connection with the forecast of dry-out point, which becomes a problem in the region of high dryness such as reactor cooling system and steam generators. Many researches have been performed on such problem in vertical tubes, but the characteristics in horizontal flow have not yet been sufficiently clarified. This series of research is to clarify various characteristics, such as the velocity of vapor phase, the flow rate distribution of droplets, the formation and adhesion of droplets and the structure of liquid film, in the region of liquid film-mist flow, where liquid film exists on the bottom of a horizontal rectangular channel, and vapor flow is accompanied by droplets. In this study, by the measurement of the flow rate distribution of droplets on respective cross sections ...

1984-06-01

306

Horizontal liquid film mist two-phase flow, 2  

International Nuclear Information System (INIS)

In the region of annular liquid film-mist flow, the behavior of the droplets formed from the liquid film and the rate of formation are the subjects to be clarified in connection with the forecast of dry-out point, which becomes a problem in the region of high dryness such as reactor cooling system and steam generators. Many researches have been performed on such problem in vertical tubes, but the characteristics in horizontal flow have not yet been sufficiently clarified. This series of research is to clarify various characteristics, such as the velocity of vapor phase, the flow rate distribution of droplets, the formation and adhesion of droplets and the structure of liquid film, in the region of liquid film-mist flow, where liquid film exists on the bottom of a horizontal rectangular channel, and vapor flow is accompanied by droplets. In this study, by the measurement of the flow rate distribution of droplets on respective cross sections ...

1984-01-01

307

Highlights of design and construction of Sendai Nuclear Power Station Unit No.2  

International Nuclear Information System (INIS)

As for No.2 plant in Sendai Nuclear Power Station, which is the fourth nuclear power generation facilities in Kyushu Electric Power Co., Inc., all works have been completed, and at present, the final trial operation is under way. In No.2 plant, many new techniques for raising the reliability and safety, improving the maintainability and reducing radiation exposure were introduced on the basis of the operation experience of PWRs obtained so far, similarly to No.1 plant. In this paper, the main items of the new techniques related to the design and construction of the plant are reported. No. 2 plant is a first improved and standardized plant having the thermal output of 2660 MW for standard three-loop PWRs, and the rated power output was set at 890 MW. As for the turbine, TC6F-40 in was adopted. As the improved design, a large reactor containment vessel, 17 x 17 type 9-grid fuel, improved steam generators, a reactor vessel cover of one-body type, a titanium tube ...

1985-01-01

308

Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus  

International Nuclear Information System (INIS)

Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.

1987-08-01

309

Genetic origin of Mesozoic natural gases in the Ordos Basin (China): Comparison of carbon and hydrogen isotopes and pyrolytic results  

Energy Technology Data Exchange (ETDEWEB)

Permian coal and Triassic mudstone from the Ordos Basin were pyrolyzed in a closed system using a gold tube technique. Carbon and hydrogen isotopes of the gases generated from pyrolysis were compared to Mesozoic gases in the basin to interpret the origin, maturity and any mixing of gases. Maturation trends for thermogenic methane from both coal and lacustrine kerogens in our experiment were found to be independent of heating rate, allowing their use for determination of gas provenance. Gases from a tectonically stable area like the Shanbei slope are derived mainly from Yanchang lacustrine kerogen, and gases in tectonically active areas consist of mixtures of coal-derived gases and oil-associated methane from deeply buried formations, as well as oil-associated gases and biogenic gases from shallow depth. The thermal maturity of the C{sub 2} and C{sub 3} gases is estimated to cover an equivalent vitrinite reflectance range from 0.7% to 1.2% R{sub ...

2010-09-15

310

Fundamentals of klystron testing  

International Nuclear Information System (INIS)

Fundamentals of klystron testing is a text primarily intended for the indoctrination of new klystron group test stand operators. It should significantly reduce the familiarization time of a new operator, making him an asset to the group sooner than has been experienced in the past. The new employee must appreciate the mission of SLAC before he can rightfully be expected to make a meaningful contribution to the group's effort. Thus, the introductory section acquaints the reader with basic concepts of accelerators in general, then briefly describes major physical aspects of the Stanford Linear Accelerator. Only then is his attention directed to the klystron, with its auxiliary systems, and the rudiments of klystron tube performance checks. It is presumed that the reader is acquainted with basic principles of electronics and scientific notation. However, to preserve the integrity of an indoctrination guide, tedious technical discussions and ...

2001-12-20

311

Extraction of molybdenum with a multielement liquid organic extraction system  

Science.gov (United States)

An extraction of molybdenum is described that provides a more predictable separation over a significantly wider acidity range than previously determined. The extraction of Mo appeared to be a function of HCl normality, with virtually complete separation above 3.6 N. A test was conducted to determine if the extraction was a function of just HCl concentration or of overall acidity. When the aqueous phases of the test sequence were all prepared at 1 N H/sub 2/SO/sub 4/ in addition to the HCl in each, the resulting extraction curves were essentially identical. Another test was performed to determine if Mo was being extracted as an iodide complex. Three aqueous solutions, which were 4 N in HCl and 26% (w/v) ascorbic acid, were prepared in culture tubes. When 25 ..mu..g of Mo was extracted from these solutions of 5 mL of organic phase, the KCl gave only a 16% extraction, the KBr gave only a 22% extraction, and the KI provided an essentially total extraction. 4 ...

1985-10-01

312

Effects of microwaves on cell survival at elevated temperatures  

Energy Technology Data Exchange (ETDEWEB)

Since microwaves are used in human cancer therapy, information on specific biological effects of microwaves at elevated temperatures is important. To help supply this information, we exposed mammalian cells (CHO) and bacteria (Serratia marcescens) to hyperthermal temperatures (43, 44, and 45/sup o/C for CHO and 48, 49, and 50/sup o/C for the bacteria) with and without microwave irradiation. Temperature control was maintained by a refrigeration-reheat system and high-velocity water recirculation. The 2450-MHz microwave source was operated in a pulsed mode with power density up to 500 mW/cm/sup 2/. As expected, the survival curve slopes for both cell types increased rapidly with temperature, doubling for each degree Celsius. Microwave irradiation produced no significant change in extrapolation number for either cell type. However, survival curves of CHO cells which received microwaves were steeper by a factor of 1.25 than their sham-irradiated controls. No ...

1981-12-01

313

Effect of dissolved oxygen, hydrazine and pH outside the crevice on the galvanic corrosion of support plate alloys  

International Nuclear Information System (INIS)

A study has been performed of the initial corrosion of support structure alloys in crevices of various geometries, when galvanically coupled to alloy 600. Corrosion rates were monitored continuously by measuring the galvanic current flowing in each couple, transduced by a zero impedance ammeter. Experiments were performed in a single-pass flowing electrolyte system, with AVT water pumped through alloy 600 tubing past the orifice of each crevice. Fourteen crevices were studied simultaneously in two parallel flow arms containing seven specimens each. The steady state AVT water pH/hydrazine/oxygen concentrations were controlled by microcomputer, allowing the effect of secondary water chemistry on the corrosion rate to be studied easily. Control of the crevice electrolyte composition was achieved by separately pumping electrolyte, at a low rate, directly into the crevices of the seven specimens in the lower flow arm. In addition, a high pressure ...

1985-03-01

314

Dynamic modeling of interfacial structures via interfacial area transport equation  

International Nuclear Information System (INIS)

The interfacial area transport equation dynamically models the two-phase flow regime transitions and predicts continuous change of the interfacial area concentration along the flow field. Hence, when employed in the numerical thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Accounting for the substantial differences in the transport phenomena of various sizes of bubbles, the two-group interfacial area transport equations have been developed. The group 1 equation describes the transport of small-dispersed bubbles that are either distorted or spherical in shapes, and the group 2 equation describes the transport of large cap, slug or churn-turbulent bubbles. The source and sink terms in the right-hand-side of the transport equations have been established by mechanistically modeling the creation and destruction of bubbles due to major bubble interaction mechanisms. In the ...

2005-01-01

315

Digital luminescent radiography: A substitute for conventional chest radiography?  

International Nuclear Information System (INIS)

The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen ...

316

Development of a new evaporator using hydrophobic membrane for radioactive liquid waste  

Energy Technology Data Exchange (ETDEWEB)

An evaporator using a hydrophobic membrane made from a polytetrafluoroethylene (PTFE) was developed to improve DF (Decontamination Factor) and to reduce evaporator size. The membrane distillation, provided by the evaporator, is a new technique for liquid purification. Fundamental experiments were carried out to develop the membrane filter (tube type, outer diameter, 8 mm; membrane thickness, 500 {mu}m) for radioactive liquid treatment. The continuous operation test using actual liquid waste was also made during about 3,000 h. (This is almost equal to the operation time of an actual evaporator per year.) The evaporation rate decreased with increase an operation time due to contamination of waste impurity. But the rate was recovered by washing the membrane with hot water and then drying it. DF was over 10{sup 4} which is ten times larger than that for a conventional system. A pilot plant (capacity, 200 kg-liquid waste/h) was constructed and its ...

1996-10-01

317

Crystal structure and magnetic properties of Sm{sub 3}ReO{sub 7}  

Energy Technology Data Exchange (ETDEWEB)

Crystals of a new ternary samarium rhenium oxide, Sm{sub 3}ReO{sub 7} were obtained by subsolidus reaction of samariumsesquioxide and rheniumdioxide (ratio 1.5:1) in sealed Pt-10Rh-tubes at 1673 K. The structure was determined by single-crystal X-ray diffraction. Sm{sub 3}ReO{sub 7} crystallizes in the orthorohombic system with unit cell dimensions a = 10.736(5), b = 7.392(3), and c = 7.519(3) in space group Cmcm (No. 63) with Z = 4. The structure consists of ReO{sub 6} octahedra, distorted SmO{sub 6} octahedra, and SmO{sub 8} prisms that are interconnected to each other to form a three-dimensional network. Rhenium has the formal oxidation state of +5 but no metal-metal bond is observed in this compound. The observed magnetization in the temperature range 4 K < T < 52 K is explained by a Curie-Weiss law modified by a temperature independent Van Vleck paramagnetism of samarium (3+).

1996-08-01

318

Comparison between small LOCA scenarios in Eastern and Western type PWRs  

Energy Technology Data Exchange (ETDEWEB)

In the frame of the use of the Relap5 thermal hydraulic code in the predictions of LOCA transient scenarios in PWRs and considering the recent development of a methodology to evaluate the related uncertainty, the response to a Small Break LOCA of Eastern and Western type PWRs has been analyzed. A four loop/horizontal Steam Generator WWER-1000 (KOZLODUY in Bulgaria) and a two loop/vertical U-tubes Steam Generator Westinghouse (KRSKO in Slovenia) nuclear power plants have been considered in the analysis. The reference transient is a 2% equivalent cold leg break accident, without High Pressure Injection System intervention, as specified in the frame of a ``counterpart test`` activity involving experimental tests on four Integral Test Facilities: LOBI (European Community), SPES (Italy), BETHSY (France) and LSTF (Japan). The code results in the two cases, also taking into account the related uncertainty as evaluated by means of the aforementioned ...

1996-07-01

319

Basic study on high performance secondary battery for electric load-leveling & electric vehicle  

Energy Technology Data Exchange (ETDEWEB)

Na/S battery can have the higher energy density and higher power density than that of existing high performance secondary battery. This battery is expected to use for electric load leveling and electric vehicle. Ni/MH battery was developed in advanced countries, but it is one of the advanced technologies which are preserved in their own country. In the study on Na/S battery, properties of B{sup -}alumina electrolyte was investigated. Also the construction technologies of this test cell was established by combining tube type of B{sup -}alumina solid electrolyte with Na-, S- electrode etc. Especially of this cell, charge/discharge performance and open circuit voltage was examined. Mi/MH battery sample were tested with SBT500 system for self-discharge rate at room temp, was measured. It was found that the electrolyte and separator can be optimized to minimize the self-discharge rate. (author). refs., figs., tabs.

1993-12-01

320

A space crystal diffraction telescope for the energy range of nuclear transitions  

Energy Technology Data Exchange (ETDEWEB)

This paper contains literature from American Power Conference Air Toxics Being Measured Accurately, Controlled Effectively NO{sub x} and SO{sub 2} Emissions Reduced; Surface Condensers Improve Heat Rate; Usable Fuel from Municipal Solid Waste; Cofiring Technology Reduces Gas Turbine Emissions; Trainable, Rugged Microsensor Identifies of Gases; High-Tc Superconductors Fabricated; High-Temperature Superconducting Current Leads; Vitrification of Low-Level Radioactive and Mixed Wastes; Characterization, Demolition, and Disposal of Contaminated Structures; On-Line Plant Diagnostics and Management; Sulfide Ceramic Materials for Improved Batteries; Flywheel Provides Efficient Energy Storage; Battery Systems for Electric Vehicles; Polymer-Electrolyte Fuel Cells for Transportation; Solid-Oxide Fuel Cells for Transportation; Surface Acoustic Wave Sensor Monitors Emissions in Real-Time; Advance Alternative-Fueled Automotive Technologies; Thermal & Mechanical Process; ...

1995-04-01

321

A calculation model for thermo-hydraulic analyses of the PGV-1000 steam generator  

International Nuclear Information System (INIS)

A calculation model was developed for the analysis of thermal and hydraulic processes in the PGV-1000 horizontal steam generator. The model makes it possible to examine the hydraulics of the primary medium, i.e., the distribution of flow velocities and mass flows in the exchanger tube system and hydraulic losses of the primary medium in the steam generator during its flow between the two connecting sites to the main circulation pipeline, spatial distribution of heat fluxes between the primary and secondary sides of the steam generator and the total transmitted thermal power, pressure on the secondary side of the generator, natural circulation of the working medium on the secondary side, and the mean circulation number, spatial distribution of the volume fraction of the steam component in the intertubular space, effect of the perforated sheet on the thermo-hydraulic processes in the steam generator, redistribution of the steam component in the ...

1994-01-01

322

Secondary system chemistry control and sludge management  

International Nuclear Information System (INIS)

Since 1975 All Volatile Treatment (AVT) has been the preferred method for controlling the secondary system operating environment in Westinghouse PWR plants. However, since AVT provides no buffering action against corrodent species present in the water as trace contaminants, utilities have initiated programs which combine control of contaminant ingress with total steam generator sludge management. The earliest applications of boric acid, to control denting type corrosion, began in 1978 and have continued up to the present time. Boric Acid has also been added as an inhibitor for SCC/IGA type corrosion since 1985. There are now approximately 30 plants operating with boric acid or boric acid/morpholine chemistry in the secondary system, and a growing number of plants where morpholine is being used as an additive to maintain pH and reduce iron transport attributable to erosion/corrosion. The impact of these modifications in the operating chemistry ...

323

Spacer grid effects on post-CHF heat transfer in an annulus geometry  

Energy Technology Data Exchange (ETDEWEB)

The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased safety margins. For instance, advanced PWRs ...

2005-07-01

324

Spacer grid effects on post-CHF heat transfer in an annulus geometry  

International Nuclear Information System (INIS)

The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased safety margins. For instance, advanced PWRs would be going to use ...

2005-05-26

325

Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report  

Energy Technology Data Exchange (ETDEWEB)

Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...

1987-07-01

326

Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report  

International Nuclear Information System (INIS)

Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...

327

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-11-16

328

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-07-01

329

Studies on improvement of heat transfer characteristics in high temperature heat exchangers, (1)  

International Nuclear Information System (INIS)

Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds number of 2.9 x 10"3 to ...

1978-01-01

330

NPP steam generator: materials and water-chemical regime  

International Nuclear Information System (INIS)

The main reasons of tube failures in steam generators (SG) are considered. 1.Stress corrosion craining which has 28% of SG (most of them have stainless steel tubes). 2. Corrosion loss of metal, which accounts for 24% of tubes (phosphate corrosion due to addition of PO into water). 3.Denting-peripheral pressing of tubes in the openings of the foundation plates by the corrosive products, which are formed on internal surface of drillings in the foundation plates made of carbon steel. 4.Separation of a plating layer on tube panels. 5.Dratting-corrosion. 6.Metal fatigue. A series of experiments were conducted to study the influence of material selection on tube reliability (stainless steel 304, inconel-600, mone-400, incalloy-800). The problem of increase of SG elements reliability is a complex one and can be solved by direct selection of material, proper control of ...

331

FRAMATOME's continuous efforts to improve steam generator corrosion resistance  

International Nuclear Information System (INIS)

Construction of the French PWR nuclear program started in the early 70s, at the time a number of operating plants in the US were being affected by the first corrosion problems. Since, at that time, its construction program was in an early stage, FRAMATOME was able to make modifications on the first units to improve steam generator resistance to corrosion. For instance, full depth expansion of the tubes in the tube-sheet using an explosive process (Westex) was performed on Fessenheim 1 steam generators already installed on site. Later on, continuous operating experience was being obtained in the US, before startup of the French units. This allowed FRAMATOME to react rapidly and take immediate corrective actions at the design stage, during fabrication and sometimes even on site in order to mitigate the risk of corrosion in the steam generators. FRAMATOME is confident that the present design of its steam generator models, including a large number ...

332

Experimental verification of the horizontal steam generator boil-off transfer degradation at natural circulation  

Energy Technology Data Exchange (ETDEWEB)

The presentation summarises the highlights of experimental results obtained for VVER type horizontal steam generator heat transfer, primary side flow pattern, and mixing in the hot collector during secondary side boil-off with primary at single-phase natural circulation. The experiments were performed using the PACTEL facility with Large Diameter (LD) steam generator models, with collector instrumentation designed specifically for these tests. The key findings are as follows: (1) the primary to secondary heat transfer degrades as the secondary water inventory is depleted, following closely the wetted tube area; (2) a circulatory flow pattern exists in the tube bundle, resulting in reversed flow (from cold to the hot collector) in the lower part of the tube bundle, and continuous flow through the upper part, including the tubes that have already dried out; and (3) mixing of the hot leg flow entering the ...

1997-12-31

333

Experimental Evaluation of Tude Support Plate Crevice Chemistry  

Energy Technology Data Exchange (ETDEWEB)

A test methodology for measuring temperature, impedance, pH, and electrochemical potential distributions within a sludge-packed tube support plate crevice in a laboratory test is described. The method successfully showed that there were large concentration gradients between the tube and tube support plate sides of the crevice. The testing also showed that strong bases concentrated more effectively than strong acids, and that the crevice pH, when exposed to seawater-based solutions, increased with increasing superheat and decreasing bulk concentration. The large variations in the crevice chemistry observed under heat transfer were eliminated upon shutdown. These new test data suggest that it might be beneficial to evaluate the variation in the extent of stress corrosion cracking with tube support plate elevation found in some steam generators in light of local chemistry changes, as well as the variation ...

2001-05-08

334

Development of a high performance air heater through use of an evacuated tube cover design  

Science.gov (United States)

Development of a high performance air heater through use of an evacuated tube cover design is described. The cover design utilizes evacuated fluorescent light tubes laid parallel in a close packed array to form an inner transparent glazing over a conventional metal absorber plate with flow behind the plate. A tempered flat glass plate was used as an outer glazing. Both clear and infrared reflective (IR) tubes were investigated. Solar transmittance tests indicate that the clear tube array has a higher transmittance than two flat sheets of low-iron glass. The IR coating produced substantial transmittance loss. Thermal conductance tests indicate that the tubes behave similar to two flat glass sheets with a vacuum in between. The IR reflective coating was only marginally effective at reducing heat conductance. Final prototype designs are presented along with collector performance ...

1980-01-01

335

Constant extension rate (CERT) testing of alloy 690 and 800 nuclear steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Constant extension rate (CERT) tests were performed on Alloy 690 and Alloy 800 nuclear steam generator tubing specimens. For the Alloy 690 specimens, tests were performed in deaerated 10% sodium hydroxide solutions at 315 deg C with a +100 mV applied potential. For the Alloy 800 specimens, tests were performed in deaerated 5% sodium hydroxide solutions at 343 deg C with no applied potential. The test specimens were machined from tubing which was produced by different manufacturing processes and in different heat treated conditions. The Alloy 690 tubing was tested in six different thermomechanical conditions, while the Alloy 800 tubing was tested in four different thermomechanical conditions. The results from the test program include a complete microstructural examination using light-optical and scanning electron microscopy. The CERT test results (such as maximum stress achieved and crack morphology) are ...

1994-12-31

336

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic ...

2000-03-01

337

Torsion of moderately thick hollow tubes with polygonal shapes  

British Library Electronic Table of Contents (United Kingdom)

A simple formulation is presented for torsion analysis of hollow tubes with polygonal shapes. Thicknesses of segments of cross section can be different. Governing equations in term of Prandtl's stress function are used to derive the formulas. The derived formulas are so simple that computations can be carried out with a pocket calculator. Several examples are presented to show the accuracy and efficiency of the formulation. The obtained results are verified by accurate finite element solutions. It will be seen that the derived formulas can be useful for analysis of thin-walled and moderately thick-walled hollow tubes.

2007-01-01

338

Thermally isolated pipeline  

Energy Technology Data Exchange (ETDEWEB)

The pipelines is provided for gases, particluarly helium, at temperature of about 1000/sup 0/C (pressure about 40 bar) and is used as the connection be tween a gas cooled high temperature reactor and a heat load. The pipe consists of a temperature-resistant inner tube, which is composed of several pipe sections, which are supported on ball bearings, and a gas tight pressurised outer tube. There are supports and insulation between the two tubes. The sub-claims concern fixing of and bearings for the pipe sections. The description is very detailed and supplemented by drawings.

1980-08-28

339

Testing of 12Kh18N10T tube steel samples tendency to intergranular corrosion  

International Nuclear Information System (INIS)

Tendency of 12Kh18N10T steel tube samples to intergranular corrosion (IGC) is investigated by an express electrochemical method in the 10% solution of H_2SO_4+0.0025 g/l of KCNS. Tendency to IGC is mainly detected on the internal surface of tube samples. It is shown that the tendency to INC under plant conditions is caused by surface carburization under its incomplete purification from the graphite lubrication.

1993-01-01

340

Stress corrosion cracking of Alloy 600 using the constant strain rate test  

International Nuclear Information System (INIS)

Nuclear grade production tubing of Alloy 600 was evaluated for stress corrosion cracking (SCC) susceptibility in high purity water at 365, 345, 325, and 290 C. Reverse tube U-bend specimens provided crack initiation data and constant extension rate tests were employed to determine the crack velocities experienced in th crack propagation stage. Initial results indicate that a linear extrapolation of data received from high temperature tests can be used to predict the service life of steam generator tubing that has been plastically deformed or is continually deforming by ''denting.''.

341

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

342

Heat transfer characteristics of laminar flow in internally finned tubes under various boundary conditions  

Science.gov (United States)

Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.

1994-06-01

343

Feasibility study on scheme of disposing spent guide tubes at Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear power plant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country

1998-12-01

344

Evaluation of optimum sheath electric field for selective production of metallic carbon nanotubes  

International Nuclear Information System (INIS)

We estimate the optimum electric field at the sheath edge and the minimum interval among the nanotubes to promote the growth of armchair-type nanotubes (metallic character) as a function of the tube length. On the basis of the electric charge distribution in a nanotube and the optimum electric filed E*_1 at the tip of a nanotube evaluated using the Hueckel-Poisson method, we calculate the structure of the electric field lines outside a nanotube in the sheath region. As the tube length increases, the E*_1 decreases. To maintain the chemical activity at the tip, the sheath electric field must be decreased. We show the decreasing rate of the sheath field to the tube length.

2006-03-21

345

Design parameters for tube cavity receivers in solar power plants  

Energy Technology Data Exchange (ETDEWEB)

The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.

1981-01-01

346

Application of neutron radiography to visualization of multiphase flows  

Energy Technology Data Exchange (ETDEWEB)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-04-01

347

Application of neutron radiography to visualization of multiphase flows  

International Nuclear Information System (INIS)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-01-01

348

Analysis of laminar flow heat transfer in uniform temperature circular tubes with tape inserts  

Science.gov (United States)

Constant property, laminar flow heat transfer in a semicircular tube with uniform wall temperature has been analyzed to define the lower bound of heat transfer augmentation in circular tubes with twisted-tape inserts. Two thermal boundary conditions, which correspond to the two extremes of the fin effect of twisted tapes encountered in practical applications, are considered. Numerical solutions, employing finite-difference formulations for the governing momentum and energy equations were carried out for the thermal entrance region and for fully developed flow.

1986-05-01

349

An investigation of turbulent convection heat transfer performance in spiral spring coil inserted tubes  

International Nuclear Information System (INIS)

This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.

1996-01-01

350

A new procedure for cutting out the broken thermocouple tubes inside the deep holes in the tube plate of moisture re-heater at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The scenario of the development of a new procedure for cutting out the broken protective wells for thermocouples inside the deep holes in the tube plate in the moisture re-heater (MSR) at Daya Bay nuclear power station is presented. Focused in the innovation and improvement of the self-made tools, the new procedure produced an effective method to cut out swing long inserts stuck inside the deep holes. (authors)

2005-09-01

351

Developement of integrated evaluation system for severe accident management  

International Nuclear Information System (INIS)

The scope of the project includes four activities such as construction of DB, development of data base management tool, development of severe accident analysis code system and FP studies. In the construction of DB, level-1,2 PSA results and plant damage states event trees were mainly used to select the following target initiators based on frequencies: LLOCA, MLOCA, SLOCA, station black out, LOOP, LOFW and SGTR. These scenarios occupy more than 95% of the total frequencies of the core damage sequences at KSNP. In the development of data base management tool, SARD 2.0 was developed under the PC microsoft windows environment using the visual basic 6.0 language. In the development of severe accident analysis code system, MIDAS 1.0 was developed with new features of FORTRAN-90 which makes it possible to allocate the storage dynamically and to use the user-defined data type, leading to an efficient memory treatment and an easy understanding. Also for ...

352

APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs  

Energy Technology Data Exchange (ETDEWEB)

A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified ...

1992-07-01

353

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

354

The interventional treatment for biliary recurrent obstruction after palliative T tube drainage in patients with obstruction due to cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To explore the interventional method to treat biliary recurrent jaundice after T tube drainage in patients with malignant obstructive jaundice due to cholangiocarcinoma. Methods: 7 biliary metallic stents were placed in 7 patients with recurrent jaundice after T-tube drainage in cholangiocarcinoma cases. Results: Stent placement was once successful in all 7 cases with successful rate of 100%. For all cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that of preoperation together with subsidence of jaundice satisfactorily for 100% after the treatment. Conclusions: Percutaneous placement of biliary metallic stents was effective economic, minimal invasive and safe for palliation of biliary recurrent jaundice after T tube drainage in cholangiocarcinoma-induced obstructive jaundice

2002-10-01

355

Strain Rate Effects on Ultimate Strain of Copper  

Science.gov (United States)

... Figure 3a. PETN Filled Tube Specimen Detonated by Exploding Bridgewire Specimen POLYETIILLENE END-CAP "1- 901am WALL IHICKNESS ...

1979-05-01

356

Steam Generator Group Project: Annual report, 1985  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...

1987-04-01

357

Steam Generator Group Project: Annual report, 1985  

International Nuclear Information System (INIS)

This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...

358

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

360

Indium(III) Compounds Containing the Neopentyl Substituent ...  

Science.gov (United States)

... learn more about the thermal stability of InNP2 Me, a sample contained in a previously evacuated tube was heated at 100°C for 13 days. Neither ...

1989-02-24

361

History of Bioterrorism: Botulism  

Medline Plus

... Pan Flu Preparedness YouTube is Your Friend Additional Resources ... Response Hurricane Readiness in High-Risk Areas: Survey Results Elements of ...

362

Far-out Pathways to Space: Great Guns? - ISTP  

Science.gov (United States)

The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he ...

363

Far-out Pathways to Space: Great Guns?  

Science.gov (United States)

Turbine Afterword The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he envisioned...

2011-09-03

364

Development of the SSC (Superconducting Super Collider) trim coil beam tube assembly  

Energy Technology Data Exchange (ETDEWEB)

The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.

1987-01-01

365

Development of a FeCoNb Alloy to be used in Eddy Current ...  

Science.gov (United States)

... Accession Number : ADD336001. Title : Development of a FeCoNb Alloy to be used in Eddy Current Probes for Testing Ferromagnetic Tubes,. ...

366

Central Venous Access Catheters (CVAC) and Gastrostomy (Feeding) Tubes  

Science.gov (United States)

... of CVACs, including tunneled catheters (Hickman or Broviac), peripherally inserted central catheters (also called PICC lines or long lines), ...

367

BAM: Staphylococcal Enterotoxins  

Science.gov (United States)

... Dialysis tubing. Cellulose casing of 1-1/8 inches flat width and an average pore diameter of 48 Angstrom units is used (12,000-14,000 mol wt exclusion). ...

368

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

369

Application of Combined Enhanced Techniques for Design of Highly Efficient Air Heat Transfer Surface  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the size and cost of heat exchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...

2012-01-01

370

A New Tool for Accurately Measuring the Inside Diameter of a ...  

Science.gov (United States)

Page 1. AD-769 272 A NEW TOOL FOR ACCURATELY MEASURING THE INSIDE DIAMETER OF A GUN BARREL, LONG TUBE, OR SIMILAR ...

1973-08-29

371

120-MM Gun Tube Erosion Including Surface Chemistry ...  

Science.gov (United States)

... with dynamic gridding capability to account for material ablation, as well as the addition of energy sources and heat transfer augmentation due to ...

1997-10-01

372

(12) United States Patent  

Science.gov (United States)

Sep 19, 2005 ... within a sealed tube to control the environment to which a sample mounts are better suited to handling the very small crystal is exposed. ...

373

Low-Cost Hydrogen Distributed Production System Development  

Science.gov (United States)

H{sub 2}Gen, with the support of the Department of Energy, successfully designed, built and field-tested two steam methane reformers with 578 kg/day capacity, which has now become a standard commercial product serving customers in the specialty metals and PV manufacturing businesses. We demonstrated that this reformer/PSA system, when combined with compression, storage and dispensing (CSD) equipment could produce hydrogen that is already cost-competitive with gasoline per mile driven in a conventional (non-hybrid) vehicle. We further showed that mass producing this 578 kg/day system in quantities of just 100 units would reduce hydrogen cost per mile approximately 13% below the cost of untaxed gasoline per mile used in a hybrid electric vehicle. If mass produced in quantities of 500 units, hydrogen cost per mile in a FCEV would be 20% below the cost of untaxed gasoline in an HEV in the 2015-2020 time period using EIA fuel cost projections for ...

2011-03-10

374

Global mode analysis of ideal MHD modes in a heliotron/torsatron system. 1. Mercier-unstable equilibria  

Energy Technology Data Exchange (ETDEWEB)

By means of a global mode analysis of ideal MHD modes for Mercier-unstable equilibria in a planar axis L=2/M=10 heliotron/torsatron system with an inherently large Shafranov shift, the conjecture from local mode analysis for Mercier-unstable equilibria given in [N. Nakajima, Phys. Plasmas 3, 4556 (1996)] has been confirmed and the properties of pressure-driven modes, namely, ballooning modes and interchange modes, inherent to such three-dimensional systems have been clarified. The change of the local magnetic shear due to the Shafranov shift, which is related to toroidicity, reduces the field line bending stabilizing effects on ballooning modes. According to the degree of the reduction of the local magnetic shear by the Shafranov shift, the Mercier-unstable equilibria are categorized into toroidicity-dominant (strong reduction) and helicity-dominant (weak reduction) Mercier-unstable equilibria. Since the local magnetic curvature due to helicity ...

1998-12-01

375

Sustainable water resources management in Pakistan  

International Nuclear Information System (INIS)

Total river discharge in Pakistan in summer season vary from 3 thousand to 34 thousand cusses (100 thousand Cusses to 1,200 thousand Cusses) and can cause tremendous loss to human lives, crops and property, this causes the loss of most of the flood water in the lower Indus plains to the sea. Due to limited capacity of storage at Tarbela and Mangla Dams on river Indus and Jhelum, with virtually no control on Chenab, Ravi and Sutlej, devastating problems are faced between July and October in the event of excessive rainfall in the catchments. Due to enormous amounts of sediments brought in by the feeding rivers, the three major reservoirs -Tarbela, Mangla and Chashma will lose their storage capacity, by 25 % by the end of the year 2010, which will further aggravate the water-availability situation in Pakistan. The quality of water is also deteriorating due to urbanization and industrialization and agricultural developments. On the Environmental Front the main problems are water-logging ...

2004-06-07

376

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger neutron flux (7.3 x 10[sup 7] n/cm[sup 2]/s) than the previous facility was constructed. A ...

1992-01-01

377

Estimation of source term release during SGTR sequences at Wolsong plants  

International Nuclear Information System (INIS)

Source term release characteristics are analyzed for the severe SGTR (Steam Generator Tube Rupture) sequences beyond the design basis accidents in Wolsong 2/3/4 plants which are of CANDU6 type reactor. In PWRs, SGTR sequences have long been recognized to be important and are distinctly different from the non-bypass sequences since there is a direct fission product release path from the primary system to the environment bypassing the containment gas volume. Meanwhile, a SGTR in a CANDU reactor is analyzed not to provide a complete and direct path into the environment for the source term resulting from a severe accident. This is because the majority of the fission product released arises from heatup and interactions of the disassembled fuel channel segments and debris in the calandria tank rather than from fuel heatup in the fuel channel. These fission products are released from the calandria tank into the containment atmosphere through the four ...

1998-10-21

378

Effects of coal syngas and H{sub 2}S on the performance of solid oxide fuel cells. Part 2. Stack tests  

Energy Technology Data Exchange (ETDEWEB)

The performance of two-cell planar solid oxide fuel cell stacks using coal syngas, with and without hydrogen sulfide (H{sub 2}S), was studied. All cells were tested at 850 C with a constant current load of 15.2 A (current density of 0.22 A cm{sup -2} per cell) and 30% fuel utilization. The H{sub 2}S injection immediately and significantly affected the power degradation of the stack system regardless of the carrier fuel. Results for the test with only H{sub 2} and N{sub 2} in the presence of H{sub 2}S (119-120 ppm) indicated that the power decay and area-specific resistance (ASR) degradation values were lower than those for the tests where simulated syngas containing CO and increased water content was used. The results indicate that contact points in the stack contributed to the power degradation of the system. Other factors, including contamination from the upstream fuel gas tubing, may have contributed to the higher ...

2007-02-10

379

Development of next-generation light water reactor in Japan  

International Nuclear Information System (INIS)

In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic isolation technologies to standardize plant design independent from ...

2009-10-27

380

Development of materials resistant to metal dusting degradation.  

Energy Technology Data Exchange (ETDEWEB)

Metal dusting corrosion has been a serious problem in the petroleum and petrochemical industries, such as reforming and syngas production systems. This form of deterioration has led to worldwide material loss for 50 years. For the past three years, we have studied the mechanism of metal dusting for Fe- and Ni-base alloys. In this report, we present a correlation between the weight loss and depth of pits that form in Ni-base alloys. Nickel-base alloys were also tested at 1 and 14.8 atm (210 psi), in a high carbon activity environment. Higher system pressure was found to accelerate corrosion in most Ni-base alloys. To reduce testing time, a pre-pitting method was developed. Mechanical scratches on the alloy surface led to fast metal dusting corrosion. We have also developed preliminary data on the performance of weldments of several Ni-base alloys in a metal dusting environment. Finally, Alloy 800 tubes and plates used in a ...

2006-04-24

381

Accident analysis in research reactors  

International Nuclear Information System (INIS)

Full text: Full text: The incomplete understanding of the complex mechanisms connected with the interaction between thermal-hydraulic and neutron kinetics still challenges the design and the operation of nuclear reactors and imposes the adoption of conservatism in the evaluation of safety limits. The recent availability of powerful computer and computational techniques together with the continuing increase in operational experience suggests the revisiting of those areas and the identification of design/operation requirements that can be relaxed. So far, almost all of the safety analyses of research reactors have been performed using conservative computational tools such as channel codes but, nowadays, the application of Best-Estimate (BE) methods constitutes a real necessity. The global aim of the current work is an attempt to apply the best-estimate system thermal-hydraulic code Relap5. For this purpose, the generic IAEA research reactor Benchmark problem is ...

2006-10-15

382

Transient burnout in flow reduction condition  

International Nuclear Information System (INIS)

A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author).

383

Tracheal laceration during intubation of a double-lumen tube and intraoperative fiberoptic bronchoscopic evaluation through an LMA in the lateral position -A case report-  

UK PubMed Central (United Kingdom)

A 76-year-old, 148-cm woman was scheduled for right upper lobectomy. A 32 Fr left-sided double lumen tube was placed using a conventional technique. Despite several attempts under fiberoptic bronchoscope-guidance,...Full Text Available

2011-04-01

384

Thermal/hydraulic tests of tube supports in a multi-tube steam generator model  

International Nuclear Information System (INIS)

Tube supports used in the tube bundles of PWR steam generators have consisted of mechanical devices located at intervals along the tube bundle. The presence of tube supports creates regions of restricted flow with altered flow patterns and increased pressure drop. An additional and very important effect is also the possibility of local complete vaporization or dryout occurring in the tube/support flow passage and crevices. The thermal/hydraulic conditions at which dryout occurs are of particular interest because of the possibility of the deposition of dissolved solids with the occurrence of dryout. As long term build-up of solid deposition could have a deleterious effect, knowledge of the conditions at which dryout occurs would possibly provide a means to avoid this build-up. A test program, sponsored by the Steam Generator Project Office of the Electric Power Research Institute, ...

1985-03-01

385

Steam generator design improvements for the candu wolsung nuclear power plant  

International Nuclear Information System (INIS)

Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.

1978-01-01

386

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

387

PWR steam generator chemical cleaning process  

International Nuclear Information System (INIS)

Some of the origins of corrosion encountered in the secondary side of pressurized water reactor steam generators are:-sludge accumulation (a mixture of metal oxides, primarily magnetite and copper) on tube sheet and attack of tube support plates by aggressive impurities leading to denting. Although Electricite de France has not suffered from these problems, it has developed a chemical cleaning process to dissolve corrosion products at both locations. (author).

1986-10-13

388

Manual corrosion  

Energy Technology Data Exchange (ETDEWEB)

In the aim to fight against tubes corrosion of geothermal wells which exploit the aquifer of Dogger reservoir in the Parisian basin, injection of corrosion inhibitors in the geothermal fluid has been generalized since 1989 by using an additive injection tube in the bottom of the well, allowing the protection of the two wells from the geothermal doublet. 3 annexes. 46 refs. 13 tabs. 9 figs.

1994-09-01

389

Esophageal perforation following bite of inner tube of automobile tyre: An unusual cause of barotrauma  

UK PubMed Central (United Kingdom)

An 8-year-old child presented with severe chest pain and respiratory distress after he accidentally bit an automobile tyre tube which burst into his mouth. The chest radiograph revealed left-sided pneumothorax....Full Text Available

2010-01-01

390

Energy conservation via heat transfer enhancement. Quarterly progress report, October 1-December 31, 1979  

Science.gov (United States)

Contacts with researchers, manufacturers, and users of enhanced heat transfer equipment are summarized. The Technical Literature file and the Patent File continue to be updated; the Patent File is the source for a patent technology report now in draft form. Application studies on a rationally-based friction correlation for internally-finned tubes and on the evaluation of candidate tube-side enhancements for OTEC applications are reported. The technology study on enhancement of spray evaporation is also discussed.

1979-01-01

391

Effective stress of a 4.2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall`s resistivity requirement ({sigma}*t = 2E5 {Omega}{sup {minus}1}). For a 4.2 K beam tube the Cu thickness is 100 {mu}m (RRR=30,6.7 T, {sigma}=2E9{Omega}{sup {minus}1}m{sup {minus}1}). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam tube ...

1993-05-01

392

Effective stress of a 4. 2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall's resistivity requirement ([sigma]*t = 2E5 [Omega][sup [minus]1]). For a 4.2 K beam tube the Cu thickness is 100 [mu]m (RRR=30,6.7 T, [sigma]=2E9[Omega][sup [minus]1]m[sup [minus]1]). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam ...

1993-05-01

393

Condenser replacement at Unterweser nuclear power station  

International Nuclear Information System (INIS)

In spite of extensive cooling water studies premature damage due to corrosion occurred on the CuZn20Al condenser tubes. It was then decided to incorporate new titanium-tubed condensers during the annual overhauls of 1983 and 1985 and also take ameliorating measures up to the exchange of individual condensers. (orig.).

394

CERAMIC MEMBRANES FOR HYDROGEN PRODUCTION FROM COAL  

Energy Technology Data Exchange (ETDEWEB)

The preparation and performance of membranes for application to hydrogen separation from coal-derived gas is described. The membrane material investigated was dense amorphous silica deposited on a suitable support by chemical vapor deposition (CVD). Two types of support materials were pursued. One type consisted of a two-layer composite, zeolite silicalite/{alpha}-Al{sub 2}O{sub 3}, in the form of tubes approximately 0.7 cm in diameter. The other type was porous glass tubes of diameter below 0.2 cm. The first type of support was prepared starting from {alpha}-Al{sub 2}O{sub 3} tubes of 1{micro}m mean pore diameter and growing by hydrothermal reaction a zeolite silicalite layer inside the pores of the alumina at the OD side. After calcination to remove the organic template used in the hydrothermal reaction, CVD was carried out to deposit the final silica layer. CVD was carried out by alternating exposure of the surface with ...

2004-04-01

395

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

Energy Technology Data Exchange (ETDEWEB)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree ...

2003-07-01

396

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

International Nuclear Information System (INIS)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree ...

2003-10-05

397

Advances in enhanced heat transfer: 1987  

Energy Technology Data Exchange (ETDEWEB)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-01-01

398

Advances in enhanced heat transfer: 1987  

International Nuclear Information System (INIS)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-08-09

399

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET ...

2002-07-01

400

Processing fine-grained and superplastic AZ31 Mg tubes for hydroforming  

Energy Technology Data Exchange (ETDEWEB)

The microstructures and mechanical properties of the AZ31 Mg tubes fabricated by one-pass forward piercing tube extrusion operated at 250-400 C and 10{sup -2}-10{sup 0} s{sup -1} are examined. The grain size is refined from the initial {proportional_to}75 {mu}m grain size down to {proportional_to}1.5 {mu}m. The room temperature tensile elongation along the extrusion direction also increases from {proportional_to}13% for the as-received billet up to 51%. The highest superplastic elongation of 610% was obtained as tensile loaded at 300 C and 2 x 10{sup -4} s{sup -1}, and high strain rate superplasticity of 406% and 502% was achieved at 300 C and 400 C with a high strain rate of 1 x 10{sup -2} s{sup -1}. Preliminary hydroforming or tube bulging at room temperature has demonstrated the feasibility. Hydroforming at elevated temperature of 200 C or above should exhibit much more promising results, utilizing the capability of LTSP ...

2004-07-01

401

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable promise for quality ...

1978-01-01

402

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2006-07-01

403

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2005-11-20

404

Determination of water level profile along heat exchange tubes of horizontal steam generator PGV 1000 M  

International Nuclear Information System (INIS)

A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may occur even in some permissible operating ...

405

Augmentation of heat transfer in a tube with an oscillating thin plate. Shindohen sonyu ni yoru enkannai netsudentatsu sokushin  

Energy Technology Data Exchange (ETDEWEB)

An attempt is made to augment the heat transfer efficiency by means of inserting an oscillating thin plate into a tube of the shell and tube heat exchanger. However, the heat transfer augmenting mechanism has not been fully explained. To elucidate this heat transfer augmenting mechanism, an investigation was given on the heat transfer characteristics of a tube inlet at its preliminary run area when a double-hinged oscillating thin plate is inserted in the inlet. As a result of the experiment, the heat transfer augmentation in the tube as a result of inserting the double-hinged oscillating thin plate was found effective when the preliminary inlet run area is treated as the object. However, in comparison of the effect with the heat transfer in a fully developed turbulent region, it was {eta}- 1. The result thus obtained explains that no sufficient turbulence can be obtained when the deflection angle of ...

1991-09-01

406

The dependence of photovoltage of the system APhV-films photoresistor on the capacity of X-ray radiation dose  

International Nuclear Information System (INIS)

Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was received with thermo vacuum slanting pulverization (#alpha#=30-60 ...

2004-08-23

407

Ultra-high temperature strength properties on Mod.9Cr-1Mo steel  

Energy Technology Data Exchange (ETDEWEB)

A sodium-water reaction drove from the single tube break in steam generator of FBR might overheat labor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. This study clarified the tensile and creep properties of Mod.9Cr-1Mo steel at ultra-high temperature which will be used in evaluation of the tube burst by sodium-water reaction. The strain rates for tensile test are from 10%/min to 10%/sec, and creep-rupture time is maximum 277sec. The range of test temperature is 700degC to 1300degC. The main results obtained were as follows; (1) The evaluation data on the relationship between tensile strength and strain rate and creep-rupture strength in shorter time on Mod.9Cr-1Mo steel were ...

2000-03-01

408

The Cause of an Eddy Current Signal Noise from a Steam Generator Tube and its Effect on the Detectability of a Crack  

International Nuclear Information System (INIS)

An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current probe from ...

2008-05-01

409

Predicting optimum vortex tube performance using a simplified CFD model  

International Nuclear Information System (INIS)

The Ranque-Hilsch tube is a particular type of vortex tube device. The flow enters the device tangentially near one end and exits from the open ends of the tube. The inlet air is of a uniform temperature throughout while the outputs are of different temperatures. One outlet is hotter and the other is colder than the inlet air. This device has no moving parts and does not require any additional power for its operation other than that supplied to the device to compress the inlet air. It has, however, not been widely used, mainly because of its low efficiency. In this paper, a simplified 2-dimensional computational fluid dynamics model for the flow in the vortex tube is developed using FLUENT. This model makes use of the assumption of axial symmetry throughout the entire flow domain. Compared to a three-dimensional computational solution, the simplified model requires significantly less computational time. ...

2004-05-09

410

Fracture inspection by BHTV logging through a vinyl chloride tube; Enbi pipe ga sonyusareta kosei deno BHTV ni yoru kiretsu chosa  

Energy Technology Data Exchange (ETDEWEB)

A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the distance between the bore wall and the vinyl ...

1997-05-27

411

Application of new corrosion-resistance superheater tubings for a 500 C, 100 Kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy plant  

Energy Technology Data Exchange (ETDEWEB)

A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. Furthermore, the design conception and basic ...

1999-11-01

412

A review of heat exchanger tube bundle vibrations in two-phase cross-flow  

International Nuclear Information System (INIS)

Flow-induced vibration is an important concern to the designers of heat exchangers subjected to high flows of gases or liquids. Two-phase cross-flow occurs in industrial heat exchangers, such as nuclear steam generators, condensers, and boilers, etc. Under certain flow regimes and fluid velocities, the fluid forces result in tube vibration and damage due to fretting and fatigue. Prediction of these forces requires an understanding of the flow regimes found in heat exchanger tube bundles. Excessive vibrations under normal operating conditions can lead to tube failure. Relatively little information exists on two-phase vibration. This is not surprising as single-phase flow induced vibration; a simpler topic is not yet fully understood. Vibration in two-phase is much more complex because it depends upon two-phase flow regime, i.e. characteristics of two-phase mixture and involves an important consideration, which is the void ...

2004-05-01

413

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

414

Summary of denting mechanism and kinetic studies with seawater  

International Nuclear Information System (INIS)

Studies at Commissariat a l'Energie Atomique (CEA) have been under way for three years in an attempt to find methods for preventing and stopping denting. Tests have been performed in 28 model boilers (Ajax with U tubes and Clarinette with straight tubes). In these boilers, with continous injection and blowdown, and heat flux is about 40 W X cm"-"2 (126900 Btu/ft"2 X h). The kinetics of denting has been studied with different levels of faulting. Some high-temperature electrochemical measurements established the mechanism of denting in the boiler tests. Denting kinetics can be rationalized in terms of three main parameters: faulting level, heat flux, and relative mechanical strength of the tube compared to the support plate.

415

Special eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heat exchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes and their performance.

1986-11-17

416

Research of time-domain equivalent circuit method in solving dispersion of coupled-cavity traveling-wave tube  

International Nuclear Information System (INIS)

In this paper, a time-domain equivalent circuit method is applied to solve dispersion of coupled-cavity travelling-wave tube (CCTWT). First, the time-domain circuit equations of CCTWT coupled-cavity chain are deduced from the equivalent circuit model. Then, the equations are solved numerically by fourth-order Runge-Kutta method and a program CTTDCP is developed using MATLAB. Last, a L-band CCTWT is calculated using CTTDCP and the cavity pass-band of this tube is computed to be 1.08-1.48 GHz, which is consistent with the experimental results and the simulation results of electromagnetic code and demonstrates the validity of the time-domain equivalent circuit method. In addition, a new design method which uses the equivalent circuit method and electromagnetic simulation together to optimize the cold cavity characteristics of CCTWT is proposed. (authors)

2008-09-01

417

Relative performance of supercritical binary geothermal power cycles with in-tube condensors in different orientations  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of the performance of binary power cycles utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation. The utilization of these concepts will improve the net geofluid effectiveness (net plant output per unit mass of geofluid) about 20% over that of a conventional binary power plant. The major prerequisite for this improvement is the achievement of integral, countercurrent condensation. Results are presented for testing of the performance of the condenser at different tube inclinations. The performance in the vertical orientation is better than in either the horizontal or inclined orientations. 7 refs., 8 figs.

1989-01-01

418

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

419

Process for filling tubular plates for lead batteries. Verfahren zum Fuellen von Rohrplatten fuer Bleiakkumulatoren  

Energy Technology Data Exchange (ETDEWEB)

The following method is proposed as a supplement to main patent 2419107, which deals with the filling of tubular plates surrounding the lead cores: the flat materials which are used to produce the jacket tubes are prepared before forming into jacket tubes by a film producing aqueous carboxy-methyl cellulose solution closing the pores. The preparation can be done by coating the flat material with a soluble foil. After pressing the paste in, the tubular plates are dried and after cooling are dipped into sulphuric acid with a specific gravity of 1.24 g/cm/sup 3/. The carboxy-methyl cellulose is dissolved and the permeability of the tube walls for electrolyte is restored after only 15 minutes.

1981-06-19

420

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

421

Offshore drilling rig with enclosed work area  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the working conditions for the operators of drilling rigs, the work area for handling of pipes and tubes is arranged on a main deck convered by a drill deck, which has openings closable by hatch cover panels. The derrick is enclosed in a cover, from which tunnels extend out over the drill deck and comprises lifting means for handling of pipes and tubes between the decks. The tunnels are connected to the cover of the derrick by raised enclosures permitting the swinging of pipes from a horizontal position in the tunnel to a vertical position in the derrick, and vice versa. There is a door, at least at one of the enclosures, permitting handling of especially long objects. Basically, the handling of pipes and tubes can be performed within areas fully protected from the weather.

1987-12-01

422

Mining User Comment Activity for Detecting Forum Spammers in YouTube  

CERN Document Server

Research shows that comment spamming (comments which are unsolicited, unrelated, abusive, hateful, commercial advertisements etc) in online discussion forums has become a common phenomenon in Web 2.0 applications and there is a strong need to counter or combat comment spamming. We present a method to automatically detect comment spammer in YouTube (largest and a popular video sharing website) forums. The proposed technique is based on mining comment activity log of a user and extracting patterns (such as time interval between subsequent comments, presence of exactly same comment across multiple unrelated videos) indicating spam behavior. We perform empirical analysis on data crawled from YouTube and demonstrate that the proposed method is effective for the task of comment spammer detection.

2011-01-01

423

Metallurgical Investigation of a Prematurely Failed Concentric Reducer Tube Used in a Hot-Rolling Mill  

British Library Electronic Table of Contents (United Kingdom)

A concentric reducer tube, which was a part of the top exit roughing hydraulic descaler in a hot strip mill failed prematurely under working pressure. A detailed metallurgical investigation comprising physical examination, optical microscopy, scanning electron microscopy, and electron probe microanalysis was carried out to find out the genesis of the failure. Physical examination revealed cracks located symmetrically around the circumference of the tube that ran along its full length, up to the weld beads at both ends. Optical microscopy of etched samples revealed a banded ferrite-pearlite structure and the existence of forging folds near the change-in-section(160? fillets). Cracks were found to initiate from these forging folds. No structural abnormalities were found in the weld beads and...

2007-01-01

424

Mechanical design of a PERMCAT reactor module  

International Nuclear Information System (INIS)

The PERMCAT is a membrane reactor proposed for processing fusion reactor plasma exhaust gas: tritium removal is obtained by isotopic swamping operating in counter-current mode. In this work, a membrane reactor using a permeator tube of length about 500 mm produced via diffusion welding of Pd-Ag thin foils is described. An appropriate mechanical design of the membrane module has been developed in order to avoid any significant compressive and bending stresses on the very long and thin wall permeator tube: two expanded bellows have been applied to the Pd-Ag tube, so that it has been pre-tensioned before operating. The elongation of the metal permeator under hydrogenation has been theoretically estimated and experimentally verified for properly designing the membrane reactor.

2007-02-01

425

Improvement of the PGV-1000 steam generator in-vessel components  

International Nuclear Information System (INIS)

Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.

1988-01-01

426

Heat transfer augmentation in liquid metal reactor steam generators  

International Nuclear Information System (INIS)

The use of heat transfer augmentation devices has been proposed as a means for reducing the cost of steam generators for advanced LMR designs by approximately 25%. Experimental results are presented for two types of enhancers in the form of a twisted-tape and a core-tube insert in the steam tube of a 13.1-m-long, sodium-heated single-tube test section. Test parameters were prototypical of liquid metal reactor (LMR) steam generator design for a once-through high-pressure steam cycle. Heat transfer results are compared with the no-insert case on an overall and local basis. Although both augmentations increased overall performance, the mechanisms were different.

427

Fluidelastic instability of heat exchanger tube bundles; Review and design recommendations  

Energy Technology Data Exchange (ETDEWEB)

This paper reports that fluidelastic instability is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to cross-flow. Most of the available data on this topic have been reviewed from the perspective of the designer. Uniform definitions of critical flow velocity for instability, damping, natural frequency and hydrodynamic mass were used. Nearly 300 data points were assembled. The authors found that only data from experiments where all tubes are free to vibrate are valid form a design point of view. In liquids, fluid damping is important and should be considered in the formulation of fluidelastic instability. From a practical design point of view, we conclude that fluidelastic instability may be expressed simply in term of dimensionless flow velocity and dimensionless mass-damping. There is no advantage in considering more sophisticated models at this time. Practical design guidelines are discussed.

1991-05-01

428

Evaluation of validity of the RELAP5/MOD3 flow regime map for horizontal tubes  

Energy Technology Data Exchange (ETDEWEB)

RELAP5/MOD3 code was developed for western type power water reactors with vertical steam generators. Thus, this code should be validated also for VVER design with horizontal steam generators. The validation work, which has been started in Lappeenranta University of Technology (LUT), has already shown some weaknesses of the code. For example the flow inside a steam generator horizontal tube in some accident cases is not correctly modelled by the code. It may be the result of erroneous prediction of the flow regime. The aim of the study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal tubes. (18 refs.).

1996-12-31

429

Thermodynamics of aqueous methyldiethanolamine (MDEA) and methyldiethanolammonium chloride (MDEAH{sup +}Cl{sup -}) over a wide range of temperature and pressure: Apparent molar volumes, heat capacities, and isothermal compressibilities  

Energy Technology Data Exchange (ETDEWEB)

Apparent molar volumes of aqueous methyldiethanolamine and its salt were determined with platinum vibrating tube densitometers over a range of temperatures from 283K=<T=<576K and at pressures from 0.1MPa to 20MPa. Apparent molar heat capacities were obtained using a Sodev Picker flow microcalorimeter at a pressure of 0.1MPa and within the temperature range of 283K=<T=<328K. Apparent molar adiabatic and isothermal compressibilities at a pressure of 0.1MPa were obtained at temperatures from 283K=<T=<313K with speed of sound measurements. The experimental results were extrapolated to infinite dilution to obtain values for the standard partial molar volumes V{sup o}, heat capacities C{sub p}{sup o}, and isothermal compressibilities {kappa}{sub T}{sup o}. The standard partial molar volumes V{sup o} for the neutral amine and its salt show increasingly positive and negative values, respectively, at high temperatures and pressures, ...

2006-08-15

430

Thermodynamics of aqueous methyldiethanolamine (MDEA) and methyldiethanolammonium chloride (MDEAH"+Cl"-) over a wide range of temperature and pressure: Apparent molar volumes, heat capacities, and isothermal compressibilities  

International Nuclear Information System (INIS)

Apparent molar volumes of aqueous methyldiethanolamine and its salt were determined with platinum vibrating tube densitometers over a range of temperatures from 283K=

2006-08-01

431

Study of the action of a phosphonate additive on steel scale deposit and corrosion in the hydrodynamic conditions of a channel flow cell; Etude de l'action d'un additif phosphone sur l'entartrage et sur la corrosion de l'acier dans les conditions hydrodynamiques d'une cellule a canal  

Energy Technology Data Exchange (ETDEWEB)

In cooling systems, an improved control of scale deposit and corrosion processes is a major challenge and an realistic evaluation tool for water treatments is of the utmost economic importance. In this study, a channel flow cell was used to allow in-situ electrochemical measurements in well defined electrolyte tube flowing conditions. An expression of the mass transfer towards the electrode was established where the diffusion-limited current is a function of Re{sup 1/3} in the laminar regime and was verified experimentally using the redox couples Fe[CN]{sub 6}{sup 4-}/ Fe[CN]{sub 6}{sup 3-} and O{sub 2}/OH{sup -}. This hydrodynamically controlled experimental device was developed to investigate scale deposit processes and to evaluate scale inhibitor efficiency using a electrochemical quartz crystal microbalance. Experiments were performed on three different waters, at various flow rates and temperatures. The efficiency of a well known ...

2000-10-17

432

On the development of the METAR family of inspection tools  

Energy Technology Data Exchange (ETDEWEB)

Since 1998, Hydro Quebec Research Centre (IREQ), in collaboration with Gentilly-2, has been working on the development of inspection devices for the feeder tubes of CANDU power plants. The first tool to come out of this work was the Metar bracelet, now used throughout the CANDU utilities, consisting of 14 ultrasonic probes held in place in a rigid bracelet to measure the thickness of the pipes and moved around manually along the pipe. Following the success of the Metar, a motorized version, i.e. the Crawler, has been developed to inspect beyond the operator arm's reach to access hard to reach place or further down the pipes in the reactor. This new system has been tested at 3 different stations and will be commercially available soon. Finally, the same technology was used to develop a motorized 2-axis crack detection device to answer new concerns about the feeder. Other configurations, depending on the demands from the industry, could ...

2003-07-01

433

Long-term optimization of fuel loading pattern using genetic algorithms and simulated annealing  

International Nuclear Information System (INIS)

This paper describes Automatic Refueling Planning System (ARPS) for a nuclear power station using Genetic Algorithms (GA) and a Simulated Annealing (SA). ARPS has been developed and verified by applying to the Fugen nuclear power station (NPS), which is a 165MWe, heavy water-moderated, boiling light water-cooled, pressure tube-type reactor developed by JNC utilizing mainly uranium and plutonium mixed oxide (MOX) fuel. Fuel loading patterns have been managed independently in the Fugen NPS since the initial core. A planning of an adequate fuel loading pattern on each operational cycle needs one to two months even for expert core management engineers, for the reason that it has multi-objective optimization and nonlinear problems. In order to achieve the optimum fuel loading pattern and a fuel cost reduction, ARPS has been developed by JNC and CRC Solutions Corporation for the last five years. ARPS firstly generates several thousand fuel loading ...

2003-04-20

434

Incident angle modifiers for flat-plate solar collectors: analysis of measurement and calculation procedures  

Energy Technology Data Exchange (ETDEWEB)

Existing test procedures for measuring and rating thermal performance require the determination of the angular response of collectors in order to account for nonnormal incident beam irradiance. Angular response measurements for four different types of collectors, each type tested by three different laboratories, are presented and analyzed. Substantial differences, both within and between laboratories, are reported for the same type collectors. An analysis of the measurement procedure shows that experimentally determined angular response parameters are subject to relatively large uncertainties. The problem results to a large extent from measuring collector efficiencies at non-normal incident angles where measurement uncertainty is of the same order of magnitude as the efficiency reduction attributable to these off-normal angles. Other factors which can affect angular response measurements and the method of correlating results are also discussed. A theoretical analysis shows that shading ...

1982-11-01

435

Improvement of top shield analysis technology for CANDU 6 reactor  

Energy Technology Data Exchange (ETDEWEB)

As for Wolsung NPP unit 1, radiation shielding analysis was performed by using neutron diffusion codes, one-dimensional discrete ordinates code ANISN, and analytical methods. But for Wolsung NPP unit 2, 3, and 4, two-dimensional discrete ordinates code DOT substituted for neutron diffusion codes. In other words, the method of analysis and computer codes used for radiation shielding of CANDU 6 type reactor have been improved. Recently Monte Carlo MCNP code has been widely utilized in the field of radiation physics and other radiation related areas because it can describe an object sophisticately by use of three-dimensional modelling and can adopt continuous energy cross-section library. Nowadays Monte Carlo method has been reported to be competitive to discrete ordinate method in the field of radiation shielding and the former has been known to be superior to the latter for complex geometry problem. However, Monte Carlo method had not been used for radiation streaming calculation in the ...

1996-07-01

436

High conductivity glass electrolytes for sodium/sulfur batteries  

International Nuclear Information System (INIS)

Sodium-ion-conducting glasses are considered a promising alternative to the ceramic electrolytes. The glass upon which the most development work has been done is a sodium borate glass, which has an ionic resistivity of about 2 x 10/sup 4/ #OMEGA#-cm at 300"0C. Because of its high resistivity, cells using this borate glass require thousands of hollow glass fibers, each about 80 micrometers outer diameter (15 micrometer wall). In spite of its greater complexity, the cell with the glass electrolyte is of interest because of its potential for lower cost and higher power than the cell with ceramic electrolyte. Recently, silicate glasses of lower resistivity have been proposed for this application. These include: a soda-alumina-silica glass (900 #OMEGA#-cm at 300"0C), a soda-zirconia-magnesia-silica glass (700 #OMEGA#-cm at 300"0C), and a soda-zirconia-silica glass (600 #OMEGA#-cm at 300"0C). These lower resistivity glasses would allow a reduction in the number of tubes ...

1986-06-01

437

Heat transfer characteristics of horizontal steam generators under natural circulation conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the heat transfer characteristics of horizontal steam generators, particularly under natural circulation (decay heat removal) conditions on the primary side. Special emphasis is on the inherent features of horizontal steam generator behaviour. A mathematical model of the horizontal steam generator primary side is developed and qualitative results are obtained analytically. A computer code, called HSG, is developed to solve the model numerically, and its predictions are compared with experimental data. The code is employed to obtain for VVER 440 steam generators quantitative results concerning the dependence of primary-to-secondary heat transfer efficiency on the primary side flow rate, temperature and secondary level. It turns out that the depletion of the secondary inventory leads to an inherent limitation of the decay energy removal in VVER steam generators. The limitation arises as a consequence of the steam generator tube bundle geometry. ...

1996-10-01

438

Heat transfer augmentation by gas-particle two-phase flow  

International Nuclear Information System (INIS)

The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat transfer mode in high temperature region, the helium which is always used in high ...

1995-06-01

439

HT technology -- All-metal sealing answers safety and environmental concerns  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the evolution of the horizontal subsea tree and its utilization in increasingly demanding applications. Initially, the Horizontal Tree was seen as a solution for wells requiring high well maintenance, such as those using electrical downhole pumps. Today, the horizontal tree is being applied to natural drive wells because of attractive whole life economics. This raises concern in a number of areas. Tubing hanger seals are permanently exposed to well fluids, and must provide high integrity sealing. This required the development of a new type of radially energized, all metal sealing system, specifically for horizontal tree applications, suitable for oil or gas service at working pressures to 15,000 psi. In addition, horizontal tree pressure integrity depends on the master valve stem, gate and bonnet seals. The need for high seal integrity also dictates that the first master valves should be integral to the main body of the ...

1995-12-31

440

Gas evolution in aluminum electrolytic capacitors  

Science.gov (United States)

Gas evolution in aluminum electrolytic capacitors constitutes one of their main drawbacks in comparison to other types of capacitors lacking a liquid electrolyte. In this respect, one of the most common causes of failure shown by liquid electrolyte capacitors is electrolyte leakage through the seal or even explosions produced by internal pressure buildup. In order to prevent these hazards, some substances, known as depolarizers, are usually added to the capacitor electrolyte with the purpose of absorbing the hydrogen evolved at the cathode (1, 2). Although the gas evolution problem in electrolytic capacitors has been known for a long time, there is a lack of literature on both direct measurements of the gas evolved and assessments of the amount of depolarizer active for the hydrogen absorption process. Aluminum electrolytic capacitors of 100..mu..F and 40V nominal voltage, miniature type (diam 8 mm, height 18.5 mm), were manufactured under standard specifications. The capacitors were ...

1984-03-01

441

Dynamic modeling of interfacial structures via interfacial area transport equation; Modelisation dynamique des structures d'interface via l'equation de transport de l'interface  

Energy Technology Data Exchange (ETDEWEB)

The interfacial area transport equation dynamically models the two-phase flow regime transitions and predicts continuous change of the interfacial area concentration along the flow field. Hence, when employed in the numerical thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Accounting for the substantial differences in the transport phenomena of various sizes of bubbles, the two-group interfacial area transport equations have been developed. The group 1 equation describes the transport of small-dispersed bubbles that are either distorted or spherical in shapes, and the group 2 equation describes the transport of large cap, slug or churn-turbulent bubbles. The source and sink terms in the right-hand-side of the transport equations have been established by mechanistically modeling the creation and destruction of bubbles due to major bubble interaction mechanisms. In the ...

2005-07-01

442

Development and characterization of carbon-bonded carbon fiber insulation for radioisotope space power systems  

Energy Technology Data Exchange (ETDEWEB)

The General-Purpose Heat Source (GPHS), an improved radioisotope heat source, employs a unique thermal insulation material, carbon-bonded carbon fiber (CBCF), to protect the fuel capsule and to help achieve the highest possible specific power. The CBCF insulation is made from chopped rayon fiber about 10 ..mu..m in diameter and 250 ..mu..m long, which is carbonized and bonded with phenolic resin particles. The CBCF shapes, both tubes and plates, are formed in a multiple molding facility by vacuum molding a water slurry of the carbonized chopped-rayon fiber (54 wt %) and phenolic resin (46 wt %). The molded shapes are subsequently dried and cured. Final carbonization of the resin is at 1600/sup 0/C. Machining to close tolerances (+-0.08 mm) is accomplished by conventional tooling and fixturing. The resulting material is an excellent lightweight insulation with a nominal density of 0.2 Mg/m/sup 3/ and a thermal conductivity of 0.24 W(m.K) in vacuum at 2000/sup 0/C. ...

1985-06-01

443

Crystal structure and magnetic properties of Sm{sub 2}ReO{sub 5}  

Energy Technology Data Exchange (ETDEWEB)

Crystals of disamarium rhenium (IV) pentoxide, Sm{sub 2}ReO{sub 5}, were obtained by subsolidus reaction of samariumsesquioxide and rheniumdioxide (ratio 1:1) in sealed Pt 10Rh tubes at 1673 K. The structure was determined by single-crystal X-ray diffraction. Sm{sub 2}ReO{sub 5} crystallizes in the tetragonal system with unit cell dimensions a = 8.646(3) {angstrom} and c = 5.747(2) {angstrom} and space group P4/n (no. 85) with Z = 4. The structure consists of isolated RE{sub 2}O{sub 8} groups and the (Sm{sub 4}O) chains are inter-connected by common oxygen atoms to form a three-dimensional network. Each Re{sub 2}O{sub 8} group is composed of a pair of rhenium each surrounded by four oxygens with a short Re-Re distance of 2.251(1) {angstrom} indicating a metal-metal bond. Rhenium has the formal oxidation state of +4. The observed magnetizations in the temperature range 1.8 < T < 100 K exhibits antiferromagnetic ordering below 2.4(1) K and ...

1997-08-01

444

Comparison between experimental data and numerical modeling for the natural circulation phenomenon  

Energy Technology Data Exchange (ETDEWEB)

There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heat exchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat transfer phenomena. Instrumentation data acquisition is performed through a computer ...

2009-07-01

445

A phenomenological model of the thermal hydraulics of convective boiling during the quenching of hot rod bundles  

International Nuclear Information System (INIS)

In this paper, a phenomenological model of the thermal hydraulics of convective boiling in the post-critical-heat-flux (post-CHF) regime is developed and discussed. The model was implemented in the TRAC-PF1/MOD2 computer code (an advanced best-estimate computer program written for the analysis of pressurized water reactor systems). The model was built around the determination of flow regimes downstream of the quench front. The regimes were determined from the flow-regime map suggested by Ishii and his coworkers. Heat transfer in the transition boiling region was formulated as a position-dependent model. The propagation of the CHF point was strongly dependent on the length of the transition boiling region. Wall-to-fluid film boiling heat transfer was considered to consist of two components: first, a wall-to-vapor convective heat-transfer portion and, second, a wall-to-liquid heat transfer representing near-wall effects. Each contribution was considered separately in ...

1983-10-14

446

1,3-dipolar cyclo addition of benzyl aside to alpha-beta-unsaturated five-membered lactones  

Energy Technology Data Exchange (ETDEWEB)

The 1,3-dipolar cyclo addition reactions between benzyl azide and the alpha,beta-unsaturated lactones crotonolactone, alpha-methylenebutyrolactone and Beta-angelica lactone have been performed. The best yields of cycloadducts were obtained by working without solvent, at 60 degree centigree in a sealed tube under nitrogen atmosphere. (3aRS,6aSR)-1-Benzyl-3 a, 4,6,6a-tetrahydro-1H-furo[3,4-d]-1,2,3-triazol-4-one and 3-benzyl-7-oxa-1,2,3-triazaspiro[4.4] non-1-en-6-one have been isolated in 36% and 78% yield from the reactions of the two first lactones respectively. The second product is the first example of this heterocyclic system. The reaction with Beta-angelica lactone yielded the primary cycloadducts (3aR,S,6RS,6aSR)-and (3aRS,6SR,6aSR)-1-benzyl-3a,4,6,6a-tetrahydro-6-methyl-1H-furo[3,4-d]-1,1,3-triazol-4-one and the nitrogen elimination product 4-benzylamino-5-methyl 1-2(5H)-furanone in 44%, 11%, and 7% yield respectively. 26 refs.

1994-12-31

448

p-Nonyl-phenol: an estrogenic xenobiotic released from "modified" polystyrene.  

UK PubMed Central (United Kingdom)

Alkylphenols are widely used as plastic additives and surfactants. We report the identification of an alkylphenol, nonylphenol, as an estrogenic substance released from plastic centrifuge tubes. This...Full Text Available

1991-05-01

449

The Mechanism and the Magnitude of Flow Boiling Augmentation in Tubes with Discrete Surface Roughness Elements (III).  

Science.gov (United States)

Related to other research on the effectiveness of flow boiling heat transfer augmentation using various types of turbulators this investigation comprises a definitive study of the effect of large discrete roughness elements on heat transfer over the entir...

1972-01-01

450

Staphylococcal Enterotoxin B: Solid-Phase Radioimmunoassay  

UK PubMed Central (United Kingdom)

An immunoassay employing 125I-labeled enterotoxin B and polystyrene tubes coated with specific antibody was used for assaying purified and crude enterotoxin. Antibody was adsorbed to untreated...Full Text Available

1971-11-01

451

Site Error There's a problem with ... - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Bending moments recorded by sensors on the aluminum tube. ... the escape rocket motor, tests also were made with the escape tower and rocket .... Incoming photographic data will be electronically converted and processed ...

452

Problems and prospects of using structural materials for horizontal steam generators  

British Library Electronic Table of Contents (United Kingdom)

Prospects for using new structural materials instead of Grade 08Kh18N10T steel for making heat-transfer tubes for horizontal steam generators with the purpose to increase their service life from 30?40 to 60 or more years are considered.

2011-01-01

453

Prediction of refrigerant void fraction in horizontal tubes using probabilistic flow regime maps  

Energy Technology Data Exchange (ETDEWEB)

A state of the art review of two-phase void fraction models in smooth horizontal tubes is provided and a probabilistic two-phase flow regime map void fraction model is developed for refrigerants under condensation, adiabatic, and evaporation conditions in smooth, horizontal tubes. Time fraction information from a generalized probabilistic two-phase flow map is used to provide a physically based weighting of void fraction models for different flow regimes. The present model and void fraction models in the literature are compared to data from multiple sources including R11, R12, R134a, R22, R410A refrigerants, 4.26-9.58 mm diameter tubes, mass fluxes from 70 to 900 kg/m{sup 2} s, and a full quality range. The present model has a mean absolute deviation of 3.5% when compared to the collected database. (author)

2008-04-15

454

Novel Technique for Aerodynamic Force Measurement in Shock Tubes.  

Science.gov (United States)

For aerodynamic force measurement in the ISL shock tunnel, the authors have developed a novel measurement technique. Its key feature is a mounting support, which releases the test model and tightens it again after a free flight duration of 10 to 15 millis...

1989-01-01

455

Modeling of soluble impurities distribution in the steam generator secondary water  

Energy Technology Data Exchange (ETDEWEB)

A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

1997-12-31

456

Minimal distensibility of pulmonary capillaries in avian lungs compared with mammalian lungs  

UK PubMed Central (United Kingdom)

Previous physiological studies suggest that avian pulmonary capillaries behave like almost rigid tubes. We made morphometric measurements to determine the diameter of the capillaries in chicken...Full Text Available

2008-02-01

457

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

Energy Technology Data Exchange (ETDEWEB)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our ...

1996-06-01

458

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

International Nuclear Information System (INIS)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our ...

459

Membrane nanotubes induced by aqueous phase separation and stabilized by spontaneous curvature  

UK PubMed Central (United Kingdom)

Tubular membrane structures are widespread in eukaryotic cells, but the mechanisms underlying their formation and stability are not well understood. Previous work has focused on tube extrusion from...Full Text Available

2011-03-22

460

Magnetic Fields in Massive Stars. II. The Buoyant Rise of Magnetic Flux Tubes Through the Radiative Interior  

CERN Document Server

We present results from an investigation of the dynamical behavior of buoyant magnetic flux rings in the radiative interior of a uniformly rotating early-type star. Our physical model describes a thin, axisymmetric, toroidal flux tube that is released from the outer boundary of the convective core, and is acted upon by buoyant, centrifugal, Coriolis, magnetic tension, and aerodynamic drag forces. We find that rings emitted in the equatorial plane can attain a stationary equilibrium state that is stable with respect to small displacements in radius, but is unstable when perturbed in the meridional direction. Rings emitted at other latitudes travel toward the surface along trajectories that largely parallel the rotation axis of the star. Over much of the ascent, the instantaneous rise speed is determined by the rate of heating by the absorption of radiation that diffuses into the tube from the external medium. Since the time scale for this ...

2003-01-01

461

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

463

Fluid dynamics analysis of a Ranque-Hilsch vortex tube  

International Nuclear Information System (INIS)

Fluid dynamic analysis of a commercial, counter-flow Ranque-Hilsch Vortex Tube (Rh vt), Ex air 25 s cfm, has been performed in this work both experimentally and numerically; in particular Rh vt cooling power and temperature separation performances have been tested in both direct cooling employment (jet impingement) and indirect cooling employment (supplying cold plates). Experimental techniques, used in this work, revealed several difficulties to produce detailed information about velocity and temperature fields inside the tube and at both the exits. Hence numerical simulation of the flow inside the tube has been conducted using the commercial Cfd code Fluent 6.3.26. Compressible, turbulent, high swirling flow inside Rh vt has been simulated by using both Rans and Les approaches. In particular several turbulence closures have been used in the Rans simulations and results have been compared with Les ones. Large Eddy ...

2008-05-01

464

Evaluation of the Widal tube agglutination test for the diagnosis of typhoid fever among children admitted to a rural hdospital in Tanzania and a comparison with previous studies  

UK PubMed Central (United Kingdom)

BackgroundThe diagnosis of typhoid fever is confirmed by culture of Salmonella enterica serotype Typhi (S. typhi). However, a more rapid, simpler,...Full Text Available

465

Evaluation of new corrosion-resistant superheater tubing in high-efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) content, etc. It was confirmed that the corrosion rate of materials positioned in the ...

1998-07-01

466

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K{sup Iscc}, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most ...

2002-07-01

467

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

International Nuclear Information System (INIS)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K"I"s"c"c, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most corrosive ...

2002-05-05

468

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

469

Does My Child Have ADHD?  

Medline Plus

September 14, 2010 ADHD: Signs, Symptoms, Research NIMH researchers talk about the symptoms of ADHD as well as the latest research. Download this video. Watch on YouTube. Transcript Announcer: ADHD- Attention Deficit Hyperactivity Disorder- is one of the ...

470

Coolant rate distribution in horizontal steam generator under natural circulation  

Energy Technology Data Exchange (ETDEWEB)

In the presentation the major factors determining the conditions of NCC (Natural Coolant Circulation) in the primary circuit and in particular conditions of coolant rate distribution on the horizontal tubes of PGV-1000 in NPP with VVER-1000 under NCC are considered. 5 refs.

1997-12-31

471

Conservative management of post traumatic thoraco diaphragmatico biliary fistula  

UK PubMed Central (United Kingdom)

We report herein a case of thoraco diaphragmatico biliary fistula in a 24-year-old male who was managed conservatively with antibiotics and tube thoracostomy and had complete radiological clearance.

2010-10-01

472

Chromium steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to investigation of alternative support designs and materials. In recent designs of steam generators the carbon steel drilled hole tube support plate has been replaced by one of quatrefoil or trefoil shape to minimize the contact area. These plates are now made of more corrosion resistant chromium steel (approx. 12%Cr) to ensure that they are less vulnerable to attack in the event of adverse boiler water chemistry. This study was initiated to examine the corrosion behavior of a range of chromium steels in the acid chloride environments characteristic of tube/support plate crevices under adverse boiler water conditions. Objectives of the study were to: 1) determine the relative susceptibility of candidate tube support plate steels to acid chloride corrosion; 2) investigate the ...

1985-03-01

473

Changing the emphasis at Bruce A  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tube plugging rates have increased markedly at Bruce since the end of the 1980s. A new programme of refurbishment aims to keep the steam generators operating successfully until around 2015. (Author).

1994-01-01

474

Changing the emphasis at Bruce A  

International Nuclear Information System (INIS)

Steam generator tube plugging rates have increased markedly at Bruce since the end of the 1980s. A new programme of refurbishment aims to keep the steam generators operating successfully until around 2015. (Author).

475

Boiler and HRSG tube failures. Lesson 2. Corrosion fatigue  

Energy Technology Data Exchange (ETDEWEB)

Fatigue damage occurs in general when a boiler tube is subject to repeat cyclic or fluctuating loading although the stress produced is below the material yield strength. The types of fatigue damage include, e.g., corrosion, thermal, mechanical, vibration, and creep fatigue. It is important to determine which form of fatigue is active, because measures to avoid repeat failures differ as the case arises. In this lesson, the focus is exclusively on corrosion fatigue. Corrosion fatigue occurs by the combined synergistic actions of cyclic loading and a corrosive environment. It is a discontinuous process with crack initiation and growth during transient periods. The excessive stresses may be caused during boiler operation by the restraint at tube attachments and by load changes (in particular during cold starts or forced cools) or during shutdown or restart of circulation boilers by thermal stratification of water along the tube ...

2009-10-15

476

Astronaut Jeff Williams Answers Your Questions  

National Aeronautics and Space Administration (NASA)

Expedition 22 Commander Jeff Williams, aboard the International Space Station 220 miles above Earth, responds to questions posted on YouTube concerning the station's orientation, life in space and the recent butterfly experiment.

2010-03-10

477

A post-labeling method for multiplexed and multicolored genotyping analysis of SSR, indel and SNP markers in single tube with bar-coded split tag (BStag)  

UK PubMed Central (United Kingdom)

BackgroundGenotyping analysis using capillary DNA sequencing with fluorescently labeled primer pairs obtained by polymerase chain reaction (PCR) is widely used, but is expensive....Full Text Available

478

A heating tube  

Energy Technology Data Exchange (ETDEWEB)

Hollow needles made of an electrically conducting material are attached by hinges in the openings of the perforated end of an insert in order to intensify heat and mass transfer. The free sections of the needles are placed outside the insert, and a wick is placed on the wall of the frame in the condensation area. The wick overlaps the inlet openings of the insert.

1980-09-23

479

A double antibody solid phase assay for DNA autoantibodies for clinical use.  

UK PubMed Central (United Kingdom)

DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available

1976-08-01

480

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

Energy Technology Data Exchange (ETDEWEB)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described ...

2007-07-01

481

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

International Nuclear Information System (INIS)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described in this ...

2007-08-19

482

Effect of water chemistry improvement on flow accelerated corrosion in light-water nuclear reactor  

International Nuclear Information System (INIS)

Flow Accelerated Corrosion (FAC) of Carbon Steel (CS) piping has been one of main issues in Light-Water Nuclear Reactor (LWRs). Wall thinning of CS piping due to FAC increases potential risk of pipe rupture and cost for inspection and replacement of damaged pipes. In particular, corrosion products generated by FAC of CS piping brought steam generator (SG) tube corrosion and degradation of thermal performance, when it intruded and accumulated in secondary side of PWR. To preserve SG integrity by suppressing the corrosion of CS, High-AVT chemistry (Feedwater pH9.8#+-#0.2) has been adopted to Tsuruga-2 (1160 MWe PWR, commercial operation in 1987) in July 2005 instead of conventional Low-AVT chemistry (Feedwater pH 9.3). By the High-AVT adoption, the accumulation rate of iron in SG was reduced to one-quarter of that under conventional Low-AVT. As a result, a tendency to degradation of the SG thermal efficiency was improved. On the other hand, it was clarified that ...

2009-10-01

483

Dynamic modeling of interfacial structures via interfacial area transport equation  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows:In the current thermal-hydraulic system analysis codes using the two-fluid model, the empirical correlations that are based on the two-phase flow regimes and regime transition criteria are being employed as closure relations for the interfacial transfer terms. Due to its inherent shortcomings, however, such static correlations are inaccurate and present serious problems in the numerical analysis. In view of this, a new dynamic approach employing the interfacial area transport equation has been studied. The interfacial area transport equation dynamically models the two-phase flow regime transitions and predicts continuous change of the interfacial area concentration along the flow field. Hence, when employed in the thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Therefore, the interfacial area transport equation ...

2004-07-01

484

Advanced Binary Geothermal Power Plancts Working Fluid Property Determination and Heat Exchanger Design  

Energy Technology Data Exchange (ETDEWEB)

The performance of binary geothermal power plants can be improved through the proper choice of a working fluid, and optimization of component designs and operating conditions. This paper reviews the investigations at the Idaho National Engineering Laboratory (INEL) which are examining binary cycle performance improvements: for moderate temperature (350 to 400 F) resources with emphasis on how the improvements may be integrated into design of binary cycles. These investigations are examining performance improvements resulting from the supercritical vaporization of mixed hydrocarbon working fluids and achieving countercurrent integral condensation with these fluids, as well as the modification of the turbine inlet state points to achieve supersaturated turbine vapor expansions. For resources where the brine outlet temperature is restricted, the use of turbine exhaust recuperators is examined. The baseline plant used to determine improvements in plant performance (characterized by the ...

1989-03-21

485

Theoretical investigations of strength of a flexible tube made of NiTi; Festigkeitstheoretische Untersuchungen einer flexiblen Huelse aus NiTi  

Energy Technology Data Exchange (ETDEWEB)

A flexible, steerable tube (distal end) of an endoscope for the application in the laparoscopic surgery has been analyzed by means of the finite-element-method (FEM). The unusual mechanical and thermal features of the used shape memory alloy (SMA) of NiTi were taken in account. The analyses showed that the strains remain in the super-elastic region up to the maximum bending of 90 and no plastic deformations occur. The application of the shape optimization (CAO) made possible finding the optimal structure of the distal end and therefore powerful reducing the maximum strains in the critical regions. (orig.)

2000-04-01

486

Peristaltic flow of a couple stress fluid in an annulus: Application of an endoscope  

Science.gov (United States)

This paper discusses the influence of an endoscope on the peristaltic flow of a couple stress fluid in an annulus under a zero Reynolds number and long wavelength approximation. The inner tube is uniform, rigid, while the outer tube has a sinusoidal wave traveling down its wall. Analytical expressions for the axial velocity, stream function and axial pressure gradient are established. The flow is investigated in a wave frame of reference moving with the velocity of the wave. Numerical calculations are carried out for the pressure rise, frictional forces and trapping. The features of the flow characteristics are analyzed by plotting graphs and discussed in detail.

2008-04-01

487

Operating experience with condenser tubes made from copper alloys and new developments; Betriebserfahrungen mit Kondensatorrohren aus Kupferlegierungen und aktuelle Entwicklungen  

Energy Technology Data Exchange (ETDEWEB)

Copper alloys are a suitable tubing material for turbine condensers and heat exchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.

2008-07-01

488

Implementation and management of Daya Bay Nuclear Power Plant in-core flux thimble tube in-service inspection  

International Nuclear Information System (INIS)

This article discusses the Daya Bay nuclear power plant in-core flux thimble tube in-service inspection method and strategy. High light of the multiple frequency eddy current technology adopted including frequency and probe choice, standard design, data acquisition process are involved. The wear defect-growing trends are studied on base of the history data, which contribute to the in-service inspection strategy decision. (authors)

2003-04-08

489

Hydrodynamics of swirling flow in a circular tube with sudden increase in cross-section and of the flow through a Borda mouthpiece  

Energy Technology Data Exchange (ETDEWEB)

By applying the mass, momentum, and angular momentum conservation laws and the maximum flow rate principle to swirling, effectively inviscid, incompressible flows in a circular tube with a sudden expansion and the direct-flow and reversed-flow Borda mouthpieces the dependence of the flow rate coefficient and mechanical energy losses on the radius ratio and nondimensional circulation is obtained. Several calculating approaches with potential and helical motion are introduced and investigated. In the case of helical motion, as the swirl decreases the axial core of the flow is found to close with a sudden change of the flow parameters.

1994-11-01

490

Development of ALLOY 800 for PWR/SG tubings resistant to IGSCC and general corrosion  

Energy Technology Data Exchange (ETDEWEB)

Resistance of ALLOY 800 as a PWR/SG tubings to IGC/IGSCC and Ni, Co release into high temperature water was evaluated as compared with ALLOYs 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made. From the results, ALLOY 800 was evaluated to be the most reliable among the high Ni alloys tested. In addition, the alloy would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti and Nb, and the prior oxidation treatments, respectively. (author).

1989-07-01

491

Detection of EDM defects under Monju support plate using experimental data from remote field eddy current probes and a multi-frequency algorithm  

International Nuclear Information System (INIS)

This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)

2006-07-01

492

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

493

Comprehensive characterization of fuel, clad and wrapper materials and assemblies for fast reactors - towards design, development and performance  

International Nuclear Information System (INIS)

The paper provides a brief description of the fuel characterization for Fast Breeder Test Reactor (FBTR) and Prototype Fast Breeder Reactor (PFBR). The development and characterization of mechanical properties of Alloy D9 clad and wrapper tubes are discussed. The problems associated with fusion welding of Alloy D9 are outlined. Non-destructive characterization of cladding tubes by optimum encircling eddy current probes, on-line and off-line neural network methods is presented. Both the on-line and off-line neural network methods could readily detect and size defects specified by the designers

2004-01-01

494

BNES materials conference a status review of alloy 800  

International Nuclear Information System (INIS)

Existing applications of Alloy 800 are summarized, with particular reference to its use in various types of reactor. The need for a co-ordinated research and development programme is stressed, and the variables to be explored are outlined. The papers relating to the problem of corrosion and cracking in water and steam are considered. the strength and ductility of Alloy 800 is considered. Finally, sections of the summary deal with the use of Alloy 800 for (a) sodium cooled fast reactor boiler tubes; (b) the high temperature gas cooled reactor; and (c) PWR steam generator tubes. (U.K.).

495

A truly commercial product  

International Nuclear Information System (INIS)

In one of the first uses of high Tc superconductors in an end-use product, Lake Shore Cryotronics and a Swiss lab have developed a liquid nitrogen level sensor using a high Tc thin film. The probe is manufactured using a seamless stainless steel tube with an yttrium-based zirconium oxide flame-sprayed on the tube. A plasma-sprayed superconductor compound is deposited on top of that. The probe is coated with a sealant that protects the superconducting film from the atmosphere. This manufacturing method has yielded an extremely durable product. Unaffected by ice formation and related mechanical problems, the superconducting level sensor can be kept in the dewar for long periods of time.

496

A review of the behaviour of alloy 800 in liquid sodium  

International Nuclear Information System (INIS)

Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heat exchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).

497

A mathematical model for a thermally coupled humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...

2006-01-01