A type of Si3N4-based nanocomposites ceramic cutting tool material was prepared by the addition of nano-scale Si3N4W whisker and nano-scale TiN particle. Cutting performance of the Si3N4/Si3N4W/TiN nanocomposite ceramic tool in machining of cast iron was investigated in comparison with a commercial sialon ceramic tool, and the tool wear mechanism was studied. The two types of cutting tools have similar cutting performance at relatively low cutting parameters, while Si3N4/Si3N4W/TiN nanocomposite tool exhibits a better wear resistance than sialon tool at the relatively high cutting parameters. The wear of sialon ceramic cutting tool is dominated by the plastic deformation, abrasive action, microcracking, pullout of grains and chemical action at the higher cutting parameters. The higher mech...
SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...
Under severe operating conditions, such as starved lubrication, performance, service life, and reliability of rolling element bearings depend on the chemical and physical interactions between the contacting surfaces, the lubricant components, and the atmosphere. The IMKT{sup 1}, PI{sup 2}, and the imt{sup 3} have been cooperating on systematic investigations of interfacial interactions in high speed grease lubricated ball bearings. These include long time tests with complete bearings lubricated with greases of different composition under defined operating conditions, conducted at the IMKT, and chemical and physical characterizations of the running surfaces at the PI and imt. At the PI, in particular the chemical nature of the boundary layers has been investigated with time of flight secondary ion mass spectrometry (TOF-SIMS). The imt has been involved in the investigations by measuring the physical/mechanical properties of ...
This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids.
Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.
A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.
The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.
Nano photonic materials are synthetically manufactured crystals at the nanoscale with the target of creating a microstructure with a special electro-magnetic periodicity. Such nano photonic materials have the ability to control light propagation and thus are capable of creating photonic bandgaps in the frequency domain. We propose using nano photonic crystals as sensors to detect microdamage in composite materials. We demonstrate using a simulation model that a nano photonic sensor attached to a composite bar experiences a significant change in its bandgap profile when damage is induced in the composite bar. The model predicts the frequency response of the nano photonic sensor using the transfer matrix method. A damage metric to evaluate the change in the frequency response is developed. Successful developments of nano photonic sensors allow damage identification at scales not attainable using current sensing technologies.
Thin films of Ni and Ni alloy have been widely used in microelectromechanical systems (MEMS) and magnetic storage systems. As the dimensions of components in these systems decrease to the micro-scale, even the nano-scale, the interfacial phenomena significantly differ to the counterparts on the macro-scale. A better understanding of micro-/nano-tribology will benefit the fabrication of the small components. In this manuscript parallel molecular dynamics (MD) simulations have been conducted to investigate the nanoscratch behavior of nickel. The simulations are performed for two cases with different indenter shapes. Case I has a sharp indenter, while the indenter in Case II is blunt. It has been found that the indenter shape significantly influences the nanoscratch deformation. The sharp ind...
ObjectivesFirst comprehensive evaluation of the mechanical properties of an epoxy adhesive in different environments using a nano-indenter. ~%~~%~Use AFM/SEM and finite element modelling to generate knowledge of the precise mechanism of indentation in the epoxy adhesive. ~%~~%~Develop an improved data reduction algorithm for generating meaningful mechanical property data from indentation tests for adhesive materials.~%~ ~%~Validate the nano-indentation method of generating mechanical property data against [continued...]DescriptionThis project aims to address the problem of insufficient data on adhesive materials for effective modelling of joint behaviour in different environments. The methodology to be used is based on depth sensing indentation tests at different loads and rates and in different environments. Post-indentation deformation and recovery will be monitored by AFM and SEM and the indentation process will be modelled using FEA and closed ...
In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The alpha,alpha-dimethylester derivative, amide derivatives and diamine derivatives, which were stable to hydrolysis, showed low blood activity levels following intravenous administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with ...
Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
Liquid metal ion sources (LMISs) with Ga as ion species are widely used in focused ion beam (FIB) technology for micromachining and surface treatment on the sub-micron and nano-scale. Key features of a LMIS for investigating mechanical properties and 3D-microfabrication of materials are long life-time, high brightness, stable ion current and a highly effective milling ability for the material to be modified. In order to increase the material removal rate, heavier ions than Ga and their clusters should be applied. Bismuth (Bi) is the heaviest, non-radio-active element in the periodic table, is non-toxic and exhibits a low melting point. We have thus produced a long-life (about 1000 h) Bi LMIS with a good beam performance, applicable in any FIB system. Since Bi is the only element in this source, it is not necessary to separate it from other ions by a mass filter. Investigation of the sputtering rate of NiTi shape memory alloys using Ga and Bi LMIS showed that, for ...
The lasing of the first free-electron laser (FEL) in the world was successfully carried out in 1977, so the history of FELs as a light source is not so long. But FELs are now utilized for research in many scientific and engineering fields owing to such characteristics as tunability of the wavelength, and short pulse and high peak power, which is difficult utilizing a common light source. Research for industrial applications has also been carried out in some fields, such as life sciences, semiconductors, nano-scale measurement, and others. The task for the industrial use of FEL is the realization of high energy efficiency and high optical power. As a means of promoting realization, the combining of an FEL and superconducting linac is now under development in order to overcome the thermal limitations of normal-conducting linacs. Further, since tuning the wavelength is carried out by changing the magnetic density of the undulator, which is now induced by moving part ...
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).
In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The #alpha#,#alpha#-dimethylester derivative (1e), amide derivatives (2a-c) and diamine derivatives (3a, b, 4), which were stable to hydrolysis, showed low blood activity levels following i.v. administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging ...
A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available
Purpose. To describe the characteristics of idiopathic macular holes (MH) on optical coherence tomography (OCT) and correlate OCT with clinical assessment. Design....Full Text Available
138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.
In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.
In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere
Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computed tomography technique is used to obtain such distributions in the area of ...
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, with a chemical yield ...
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, with a chemical yield ...
Full Text: Smallstage Dualbeam (SDB) systems, that is a Focussed Ion Beam column coupled with a SEM column, have been around for about five years now. There impact on the Semiconductor industry has been enormous, with virtually every lab having a SDB to produce, characterise and analyse cross sections and TEM samples on the Nano-scale. But what about other industries? What else can SDB system be used for? The SEM column in itself is a very powerful tool for sample characterisation, modification and analysis. An electron beam from a Tungsten or Thermal Field Emission source has enough current to allow sophisticated patterns to be created in photo-resist samples, a process known as lithography. The current is also high enough to allow for a process known as Electron Beam Induced Deposition (EBID), where the beam interacts with an introduced gas and material is deposited in a controlled manner on the sample. With the addition of the Focussed Ion Beam (FIB) direct ...
This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed...Full Text Available
Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available
The purpose of this study was to determine the thickness of the macula and the retinal nerve fiber layer (RNFL) in Japanese subjects by Stratus optical coherence tomography (OCT), and to compare the...Full Text Available
ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available
PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available
Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.
Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.
A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.
Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of ...
The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488
Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author).
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available
A case of intrathoracic lipoma in a child is presented. The diagnosis was made before operation by means of computer-assisted tomography, a non-interventional procedure.
The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary ...
Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or "2"1"2Pb could serve as sources for highly ...
This paper discusses the structural and compositional changes at the nanometer scale associated with the nucleation and growth of #alpha# precipitates in the #beta# titanium alloy Ti-5553 (Ti-5Al-5Mo-5 V-3Cr-0.5Fe) with #omega# precipitates acting as heterogeneous nucleation sites. The microstructural evolution in this alloy, during #beta#-solutionizing, quenching and aging type heat-treatments, has been investigated by combining results from scanning electron microscopy, orientation imaging microscopy, transmission electron microscopy, high-resolution TEM and three-dimensional atom probe (3DAP) tomography. Athermal #omega# precipitates form in this alloy on quenching from above the #beta# transus temperature. On isothermal annealing at low temperatures, these #omega# precipitates coarsen to form chemically ordered #omega# precipitates, accompanied by the nucleation of the stable #alpha# phase. Annealing at higher temperatures leads to ...
Efficiency and Renewable Energy EERE Home | Programs & Offices | Consumer Information Chemicals Search Search Help Chemicals EERE » Industrial Technologies Program » Chemicals...
It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.
We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.
The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.
Computed tomographic findings in developmental brain anomalies are more easily classified when the system used is based on embryogenesis related to morphology. Analysis of computed tomographic findings in a series of 154 patients with brain anomalies (Chiari malformation not included) revealed that specific examples of abnormalities occurring in major stages of brain development may be recognized by computed tomography. This paper deals with a group of patients with abnormalities that reflect a disturbance in neuronal migration. (orig.).
Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)
Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.
In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can ...
The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and Computerized ...
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
The authors have evaluated bone mineral content in the vertebral spongiosa by means of Computed Tomography. The method proposed by Genant and Cann [17, 18] has been applied to examine 164 healthy volunteers and 108 patients. Both healthy males and females showed a progressive bone mineral loss increasing with age; the bone mineral loss was most severe in females during the 4th and 5th decade of life. Pathology included patients with osteoporotic fractures (vertebral and femural neck), patients with partial gastrectomy, renal failure, primary hyperparathyroidism, Cushing syndrome, corticosteroid therapy. Bone mineral values were significantly lower in most pathologic groups. Computed Tomography proves thus to be a valuable method to assess bone mineral content and to identify patients at risk for fractures.
Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters
Cancer, by definition, is a proliferative disease. The fundamental scientific issue explored at the international symposium "Cell Proliferation and Chemical Carcinogenesis" was the impact of chemically...Full Text Available
Chemical leucoderma is an industrial disorder in developed countries and the common causative chemicals are phenols and catechols. Due to stringent controls and preventive measures the incidence has...Full Text Available
The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring ...
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available
Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available
BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available
To determine the diagnostic accuracy of iofetamine hydrochloride I 123 (IMP) with single photon emission computed tomography in Alzheimer's disease, we studied 58 patients with AD and 15 age-matched healthy control subjects. We used a qualitative method to assess regional IMP uptake in the entire brain and to rate image data sets as normal or abnormal without knowledge of subjects'clinical classification. The sensitivity and specificity of IMP with single photon emission computed tomography in AD were 88% and 87%, respectively. In 15 patients with mild cognitive deficits (Blessed Dementia Scale score, less than or equal to 10), sensitivity was 80%. With the use of a semiquantitative measure of regional cortical IMP uptake, the parietal lobes were the most functionally impaired in AD and the most strongly associated with the patients' Blessed Dementia Scale scores. These results indicated that IMP with single photon ...
BackgroundNew technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic...Full Text Available
The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available
RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available
AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available
PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available
Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available
The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.
PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)
We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available
BackgroundIn vitro data suggest that changes in myocardial substrate metabolism may contribute to impaired myocardial function in diabetic cardiomyopathy (DCM)....Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
The paper investigates computerized tomography capabilities in showing vascular complications secondary to intestinal obstruction and for assessing the site and cause of obstruction. [Italian] Scopo del lavoro e' lo studio dell'uso della tomografia computerizzata nel riconoscimento di complicanze vascolari secondarie ad occlusione intestinale e della presenza, della natura e della sede dell'ostacolo alla canalizzazione intestinale.
Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)
Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).
Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
Thirty-seven patients with histologic proof of cholangiocarcinoma at the confluence were examined by computed tomography (CT) to determine whether this examination is of value in the assessment of these patients for surgery and whether there are any features specific to this type of tumor. Thirty-two patients showed intrahepatic duct dilatation; six of these showed dilatation of ducts in one lobe only. Eighteen patients had intrahepatic low-attenuation areas, while eight had a mass lesion in the porta hepatis. The results of this study show that CT provides useful anatomic information preoperatively but that the appearances are nonspecific. Lobar atrophy is highly suggestive of hilar cholangiocarcinoma, either of long-standing or with unilateral portal venous involvement.
In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.
Computed tomography (CT) has already proved extremely effective both in cerebral and abdominal pathology. Several recent publications describing first heterogeneous series [1, 2, 7, 11-17], then studies of a single type of lesion [3-6, 8] have illustrated its usefulness in the study of bone lesions. This report deals with 41 cases of Ewing's sarcoma studied by CT at the Institut Gustave Roussy from October 1977 to July 1981, and tries to show both the limitations and indications of this technique for the diagnosis, treatment, and follow-up of Ewing's sarcoma as well as in the diagnosis of any eventual recurrence. (orig.).
In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Background: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. Purpose: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). Images from four anatomical levels ...
Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map ...
Chemical oxidation is a treatment technology that uses powertul chemical oxidizers to destroy organic contaminants. Typical oxidizers used in chemical oxidation processes include ozone, hydrogen peroxide, chlorine, and potassium permanganate. The chemical reaction products are usually simple organic compounds, such as carboxylic acids, and/or inorganic compounds, such as carbon dioxide, water, and simple inorganic complexes (e.g., chloride salts, in the case of chemical oxidation treatment of chlorinated solvents).
Coatings and sensors having both steric and chemical selectivity. Controlled porosity provides the steric selectivity, whereas chemically tailored film properties, using controlled composition or modification by coupling agents, chemical species replacement, or chemical species within pores, provide the chemical selectivity. Single or multiple layers may be provided.
Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and differed in 25, lumen narrowing being ...
As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, we extend the isotropic bending ray ...
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with ...
Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to pluridirectional ...
In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy ...
Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...
Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...
Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 ...
Purpose: To describe the clinical aspects and evaluate optical coherence tomography of macular microholes. Methods: Seven patients were assessed (8 eyes) with microholes of the macula. All patients underwent complete eye examination, fundus photography, fluorescent angiography and OCT-3 imaging. Results: Ages ranged from 26 to 69 years. Six patients were female (85.7%) and five of them had microhole in the right eye. The presenting symptom was decrease in visual acuity (71.3%) and central scotoma in (14.3%). Five eyes (71.4%) had no defects shown by fluorescent angiography. A defect in the outer retina was demonstrated in all eyes on optical coherence tomography. The lesions were nonprogressive. Conclusion: Macular microholes are small lamellar defects in the outer retina. The condition is nonprogressive, generally unilateral and compatible with good visual acuity. Fundus biomicroscopy associated with an optical coherence ...
Comparative studies of flocculent and grand-design spirals suggest that density waves are not the predominant trigger of star formation in most galaxies. Implications for chemical evolution are profound. It may be possible to ignore the details of the spiral-wave phenomenon in research aimed at unifying the chemical properties of spiral disks. 16 references.
BackgroundA key question in the risk assessment of exposures to multiple chemicals is whether mixture effects may occur when chemicals are combined at low doses which individually...Full Text Available
Simultaneous or prior exposure to one chemical may alter the concurrent or subsequent response to another chemical, often in unexpected ways. This is particularly true when the two chemicals...Full Text Available
Environmental chemicals that function as estrogens have been suggested to be associated with an increase in disease and dysfunctions in animals and humans. To characterize chemicals that may act as...Full Text Available
An approach to generate mimics of phosphorylated serine proteins chemically through site-specific sulfonation of cysteine is presented. This chemical modification is reversible in the presence of reducing agent and therefore is analogous to the kinase/phosphatase system used in nature. PMID:21717004
The experimental data set used to evaluate site-specific histopathologic correspondence between the morphologic end points of toxicity and carcinogenicity comprises 130 chemical carcinogenesis studies....Full Text Available
We present a novel preparation method for studies of in vitro reconstituted mitotic chromosomes from Xenopus laevis egg extracts. This method involves a gentle adsorption of chromosomes from the extracts using surface affinity enrichment, followed by plunge freezing, freeze-substitution and cryo-embedding before examination by EM tomography. For comparison, chromosomes were also prepared by a conventional method, which included immobilization of chromosomes in agarose and a room-temperature dehydration (embedding) protocol. Three-dimensional reconstructions showed that samples prepared with the new method have a greater interconnectivity of sub-structural features and a higher compaction ratio together with an apparently less perturbed chromatin structure than those prepared using the conventional approach. The implications of the new method for the preparation of other difficult samples and additional application possibilities are discussed.
The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool
We have developed a method for the synthesis of C-11 iodoantipyrine. Carbon-11-labeled methyl iodide, prepared from /sup 11/CO2, was used to methylate 3-methyl-1-phenyl-2-pyrazolin-5-one to form C-11 antipyrine. Following silica-gel column chromatography and iodination, radiochemical purity of the C-11 iodoantipyrine was more than 99.5%, with a 10% yield and a specific activity of 30 mCi/mumol. Preliminary animal studies showed complete cerebral extraction and local cerebral blood-flow values that were within 4.6% of those obtained using C-14 iodoantipyrine. The C-11 analog, with positron emission tomography, will facilitate local cerebral blood-flow studies in human subjects.
The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.
Six patients with diskitis following lumbar disk surgery were investigated by Computed Tomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic patients.
Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...
A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the ...
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma.
Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...
Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...
Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
PurposeTo characterize the morphology of outer retinal holes caused by solar maculopathy, using spectral-domain optical coherence tomography (SD-OCT). DesignThis study is an observational case series. MethodsThe SD-OCT findings of 3 patients (6 eyes) with chronic solar maculopathy are presented. ResultsSD-OCT demonstrates a characteristic appearance of partial-thickness hole(s) in the outer retina at the fovea. In 3 of 6 eyes, there is 1 hole directly beneath the umbo. In the remaining 3 eyes, there are multifocal holes spread across the fovea. Holes in more restricted layers, as had been previously reported with time-domain OCT, were not seen. In addition, advanced visualization of SD-OCT data demonstrates a hyperreflective ring around the outer retinal hole. ConclusionsSD-OCT can be used...
Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)
Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)
Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.
Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).
In 9 over 12 patients who underwent cardiac transplantation computed tomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.
Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs.
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with ...
A simple and efficient method for characterization of multidimensional Gaussian states is suggested and experimentally demonstrated. Our scheme shows analogies with tomography of finite dimensional quantum states, with the covariance matrix playing the role of the density matrix and homodyne detection providing Stern-Gerlach-like projections. The major difference stems from a different character of relevant noises: while the statistics of Stern-Gerlach-like measurements is governed by binomial statistics, the detection of quadrature variances correspond to chi-square statistics. For Gaussian and near Gaussian states the suggested method provides, compared to standard tomography techniques, more stable and reliable reconstructions. In addition, by putting together reconstruction methods for Gaussian and arbitrary states, we obtain a tool to detect the non-Gaussian character of optical signals.
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
The Molecular Genetics and Carcinogenesis Section conducts studies using human epithelial cells to assess: activation of proto-oncogenes by chemical and physical carcinogens; inactivation and dysregulation of tumor suppressor genes by chemical and physical
Hard Nano-Strutural Coatings Resistant to the Extreme Conditions of Chemical, Abrasive and High Energy Media for Thermonuclear Power, Oil and Gas and Chemical Industries
Immunomodulation by environmental chemical contaminants and the role immune parameters play in toxicity and risk assessment studies is of increasing concern. Although considerable evidence has indicated...Full Text Available
Recent field observations have shown that the atmospheric plumes of quiescently degassing volcanoes are chemically very active, pointing to the role of chemical cycles involving halogen species and...Full Text Available
The immune system plays a crucial role in maintaining health; however, accumulating evidence indicates that this system can be the target for immunotoxic effects caused by a variety of chemicals including...Full Text Available
The existence of thresholds for toxicants is a matter of debate in chemical risk assessment and regulation. Current risk assessment methods are based on the assumption that, in the absence of sufficient...Full Text Available
OBJECTIVES: To assess the suitability of analyzing functional images of brain serotonin (5-HT) synthesis with statistical parametric mapping (SPM), and to investigate further possible sex-related regional...Full Text Available
A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.
A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.
Scintigraphic imaging of dementia relies today essentially on the study of brain Single Photo Emission Computed Tomography (SPECT) perfusion, after intravenous injection of 99mTc radio-pharmaceutic. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear Medicine (http://eanm.org/). (author)
70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.
Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.
In developing new receptor-site specific brain imaging agents labeled with I-123 for single photon emission computed tomography (SPECT), an analog of raclopride, 3-["1"2"5I]-iodo-N-[(1-ethyl-2-pyrrolidinyl)-methyl]-2-hydroxy-6-me-thoxy benzamide (IBZM), was prepared using a method similar to that reported for raclopride and its derivatives. (author).
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).
To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).
A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.
Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.
As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.
Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).
A 21-year-old male patient was transferred to the emergency room of our hospital after suffering seat belt abdominal injury in a traffic accident. Abdominal computed tomography revealed a massive hematoma...Full Text Available
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).
Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computed tomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.
The authors present an unusual case of a patient with orbital metastases from renal carcinoma involving the extra ocular muscles bilaterally. The importance of computed tomography for the differential diagnosis with other orbital lesions is emphasized. (author)
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
Humans are exposed to chemicals in contaminated groundwaters that are used as sources of drinking water. Chemicals contaminate groundwater resources as a result of waste disposal methods for toxic chemicals, overuse of agricultural chemicals, and leakage of chemicals into the subsurface from buried tanks used to hold fluid chemicals and fuels. In the process, both the solid portions of the subsurface and the groundwaters that flow through these porous structures have become contaminated. Restoring these aquifers and minimizing human exposure to the parent chemicals and their degradation products will require the identification of suitable biomarkers of human exposure; better understandings of how exposure can be related to disease outcome; better understandings of mechanisms of transport of pollutants in the heterogeneous structures of the ...
Production treatment chemicals represent a diverse collection of chemical classes, added at various points from the wellhead to the final flotation cell, to prevent operational upsets and enhance the separation of oil from water. Information in the literature indicates that while many treatment chemicals are thought to partition into oil and not into the produced water, there are cases where a sufficiently water soluble treatment chemical is added at high enough concentrations to suggest that the treatment chemical may add to the aquatic toxicity of the produced water. A study was conducted to evaluate the potential effect of production treatment chemicals on the toxicity of produced waters using the US EPA Seven-day Mysidopsis bahia Survival, Growth and Fecundity Test. Samples of produced water were collected and tested for toxicity from three platforms under ...
Several works about annual meeting of the Brazilian Chemical Society are present.The search for medicinal chemistry, natural products, biological chemistry, and organic chemistry are shown. Conventional methods and some techniques are discussed and developments of new methods of determining are studied. The use of new chemical compounds, materials, structures and chemical analysis are shown.
Transformation of row material to the consumption goods proceeds by the succession of various technologies using energy and chemicals. Relative contribution of both factors is broadly varied. The chemical reagents are not per se consumption goods and their production is auxiliary. Maximal usage of chemicals is observed in conventional technologies. On the contrary radiation technology does not need chemicals. Therefore usage of radiation technology leads to diminution of chemical processing and hence to the attenuation of the technological press on the environment. As examples the radiation technological methods in conversion of coal and biomass are considered. (author).
In the United States, estimates show that more than 30,000 hazardous waste disposal sites exist, not including military installations, U.S. Department of Energy nuclear facilities, and hundreds and thousands of underground fuel storage tanks; these sites undoubtedly have their own respective hazardous waste chemical problems. When so many sites contain hazardous chemicals, how does one study the health effects of the chemicals at these sites? There could be many different answers, but none would be perfect. For an area as complex and difficult as the study of chemical mixtures associated with hazardous waste disposal sites, there are no perfect approaches and protocols. Human exposure to chemicals, be it environmental or occupational, is rarely, if ever, limited to a single chemical. Therefore, it is essential that we consider multiple ...
Due to the large number of chemicals in commerce without adequate toxicity characterization data, coupled with an ineffective federal policy for chemical management in the United States, many states are grappling with the challenge to identify toxic chemicals that may pose a risk to human health and the environment. Specific populations (e.g., children, elderly) are particularly sensitive to these toxic chemicals. In 2008, the Children's Safe Product Act (CSPA) was passed in Washington State. The CSPA included specific requirements to identify High Priority Chemicals (HPCs) and Chemicals of High Concern to Children (CHCCs). To implement this legislation, a methodology was developed to identify HPCs from authoritative scientific and regulatory sources on the basis of toxicity criteria. Another set of chemicals of concern was then identified ...
Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei and their return to aligned rest is used ...
When Congress passed the Emergency Planning and Community Right-to-Know Act of 1986 (EPCRA), it created a number of new reporting requirements for companies that handle toxic chemicals and products containing toxic chemicals. Section 313 of EPCRA requires that certain manufacturers report annual releases to the environment of listed toxic chemicals and chemical categories. Because these manufacturers must know the toxic chemical composition of the products they use to be able to calculate releases accurately, EPA requires some suppliers of mixtures or trade name products containing one or more of the listed section 313 toxic chemicals to notify their customers. The pamphlet explains which suppliers must notify their customers, who must be notified, what form the notice must take, and when it must be sent.
Summary Although risk assessments are typically conducted on a chemical-by-chemical basis, the 1996 Food Quality Protection Act required the US Environmental Protection Agency to consider cumulative risk of chemicals that act via a common mechanism of toxicity. To this end, we are conducting studies with mixtures of chemicals to elucidate mechanisms of joint action at the systemic level with the goal of providing a framework for assessing the cumulative effects of reproductive toxicants. Previous mixture studies conducted with antiandrogenic chemicals are reviewed briefly and two new studies are described. In all binary mixture studies, rats were dosed during pregnancy with chemicals, singly or in pairs, at dosage levels equivalent to approximately one-half of the ED50 for hypospadias or e...
Treatment chemicals are used in all facets of the natural gas industry (NGI) from well development through transmission and storage of natural gas. The multitude of chemicals used, combined with the dozens of chemical manufacturers and/or suppliers has lead to the availability of hundreds of possible chemical products. Because of the widespread use of chemical products and their numerous sources, the NGI needs access to consistent data regarding their effectiveness and potential environmental impacts. The objective of this work was to evaluate the effectiveness and potential environmental impacts of, chemical products used in the NGI. This assessment was initially focused on biocides and corrosion inhibitors and their use in the gas production, storage and transmission facilities, The overall approach was obtain the necessary data on ...
Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV includes 9 cases in ...
Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury resulting blindness. CT was superior to ...
Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through the ethmoidal (70%) and ...
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety ...
The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. Since the FEM (Finite Element Method) ray tracing we have developed goes well the inverse velocities structure, we can apply the inversion problem to complex geological model. This report consists of 3 articles. 1) Development of 2-D ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).
The production of radiopharmaceuticals used in positron emission tomography (PET) can require large amounts of activity at the start of synthesis in order to yield sufficient labeled material for clinical studies. Several investigators have developed remote and automated systems for the routine production of PET radiopharmaceuticals in order to reduce radiation exposure to personnel. Such devices, however, suffer from limited flexibility and can be relatively complicated in design. These systems are also limited to the production of a single or a few closely related compounds. Furthermore, changes in chemistry would require considerable modifications in hardware and/or software in order to bring the device back into operation. To circumvent the above limitations associated with the remote production of PET radiopharmaceuticals, the authors have investigated the use of laboratory robotics as a flexible alternative to the synthesis of several short-lived ...
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image and offsets the ...
Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently examined with CT, which ...
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...
To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous epithelium to the ...
Ionizing radiation is a standard treatment for various human solid tumors. However, several clinical studies showed that a significant proportion of patients undergoing radiotherapy for hepatocellular carcinoma (HCC) develop intrahepatic and extrahepatic metastasis. Understanding of radiation-induced cancer cell invasiveness and behavior is essential and of great important for developing suitable treatment strategies to contain cancer spread. Therefore, in this study we evaluated the effectiveness of using swept source optical coherence tomography (SS-OCT) to monitor the enhancement of HCC cell invasiveness by radiation. SS-OCT images were acquired and recorded to obtain three-dimensional data sets per four hours in 48 hours after irradiating HepG2 cells with 7.5 Gy. The cell migration behavior in three-dimensional tissue models was quantified from images of radiation-induced and sham-irradiated cells.
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...
Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...
Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any diagnostic certainty were selected for follow-up, and 92% (85/92; 95% CI ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a ...
Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of C.A.T., this paper is an ...
Forty-one cases of mediastinal tumor examined by computed tomography were reviewed. CT findings of the mediastinal malignancy were as follows: 1) inhomogeneous density on contrast CT, 2) equivocaton of fat plane surrounding the tumor, 3) irregular margin. Benign teratoma had smooth margin and included fat or calcification density. Mediastinal seminoma was observed as a lobulated mass with no calcification on CT. These findings were similar to the patterns of malignant thymoma or lymphoma. Consequently, it was very difficult to differentiate between malignant thymoma and malignant lymphoma by CT. According to our data, malignant thymoma tended to expand to only one side of the anterior mediastinum and to invade the anterior chest wall. On the other hand, malignant lymphoma of anterior medistinal type expanded into the trachea and the superior vena cava. In patients with sarcoidosis, the enlargement of bilateral hilar lymph nodes was commonly observed, on the ...
As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of either the anatomical or functional imaging ...
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional ...
In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size between the cases with proximal abnormal accumulation and those ...
Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research ...
This book examines some of the basic principles behind chemical reaction kinetics. Topics considered include the classical trajectory approach to reactive scattering; periodic orbits and theory of reactive scattering; and semiclassical reactive scattering.
The Bureau of Mines performed chemical research to elaborate details of sulfur chemistry pertaining to the citrate flue gas desulfurization process in which sulfur dioxide (SO2), absorbed (as bisulfite ion) in a buffered sodium citrate solution, is reduce...
This report summarizes the major activities conducted in the Chemical and Energy Research Section of the Chemical Technology Division (CTD) at Oak Ridge National Laboratory (ORNL) during the period January--March 1997. Created in March 1997 when the CTD Chemical Development and Energy Research sections were combined, the Chemical and Energy Research Section conducts basic and applied research and development in chemical engineering, applied chemistry, and bioprocessing, with an emphasis on energy-driven technologies and advanced chemical separations for nuclear and waste applications. The report describes the various tasks performed within seven major areas of research: Hot Cell Operations, Process Chemistry and Thermodynamics, Molten Salt Reactor Experiment (MSRE) Remediation Studies, Chemistry Research, Separations and Materials Synthesis, Solution ...
The lung has the potential of metabolizing many foreign chemicals to a vast array of metabolites with different pharmacological and toxicological properties. Because many chemicals require metabolic...Full Text Available
Regulatory agencies currently rely on rodent carcinogenicity bioassay data to predict whether or not a given chemical poses a carcinogenic threat to humans. We argue that it is always more useful to...Full Text Available
Ion-channels can be activated (gated) by a variety of stimuli including chemicals, voltage, mechanical force or temperature. Whereas molecular mechanisms of ion-channel gating by chemicals and...Full Text Available
This study investigated weathering effects on polyvinyl chloride (PVC) based wood plastic composites (WPC), with a focus on the color and structure that is attributed to the material composition. It is directed towards quantifying the main chemical modifi...
The aim of this paper is to obtain the effective potential of the non-topological soliton model at finite temperature with the assumption that the chemical potential {mu} of the system is different from zero and to analyse how the effective potential is influenced by changes in the chemical potential and temperature. (author)
The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.
Importance of the fieldThe cytochrome P450 (CYP) isoforms that are selectively induced following exposure to structurally-diverse chemicals often are the ones capable...Full Text Available
A workshop on alternative toxicological testing methodologies was convened by the Scientific Group on Methodologies for the Safety Evaluation of Chemicals (SGOMSEC) 26-31 January 1997 in Ispra, Italy,...Full Text Available
The reactive airways dysfunction syndrome (RADS), the reactive upper airways dysfunction syndrome (RUDS), the sick building syndrome (SBS), and the multiple chemical sensitivity syndrome (MCS) are overlapping...Full Text Available
The mechanism by which mechanical force regulates the kinetics of a chemical reaction is unknown. Here, we use single-molecule force–clamp spectroscopy and protein engineering to study the effect...Full Text Available
The binding of amphiphilic molecules to lipid bilayers is followed by 19F NMR using chemical shift and line shape differences between the solution and membrane-tethered states of...Full Text Available
Mineral scale formation in water distribution piping impedes flow, resulting in pressure and volume reduction and increasing operational costs. Chemical cleaning is both costly and time consuming, and there are health concerns when chemically cleaning pot...
Thirty-seven papers were presented at this conference in five sessions. Topics covered include regulation, control and consequences of decontamination; decontamination of components and facilities; chemical and non-chemical methods of decontamination; and TMI decontamination experience.
Lipopolysaccharides from different bacteria isolated from cotton were purified and chemically analyzed. Their pulmonary toxicity to animals was tested in inhalation tests. Lipopolysaccharides from Agrobacterium...Full Text Available
K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)
The administration of chemicals at the maximum tolerated dose (MTD) in standard animal cancer tests is postulated to increase cell division (mitogenesis), which in turn increases rates of mutagenesis...Full Text Available
Initial results obtained with a Monte Carlo computer program designed to link initial physical events in irradiated liquid water with subsequent chemical and biological events are presented. 10 refs., 4 figs., 3 tabs.
This project addresses the problem of flue gas desulfurization (FGD) sludge disposal to land. Specifically, the chemical species of FGD sludge constituents are thermodynamically modeled using the equilibrium constant approach, in an attempt to predict the constituent concentratio...
Two additional hyperfine components of the interstellar radical C3H were detected. In addition, methanol was discovered in interstellar clouds. The abundance of HCCN and various chemical isomers in molecular clouds was investigated.
The report gives results of an examination, including mutagenic screening, of the chemical composition of residual fuel oils and their column chromatography pre-fractions. A degree of correlation between composition and mutagenicity has been achieved. Radionuclide data has been o...
Model systems to study the effects of chemicals of environmental concern on bacterial and parasitic diseases as well as the immunosurveillance and destruction of transplantable tumor cells were described...Full Text Available
It is well established that changes to the chemical environment can impair development, physiology and reproductive biology; by contrast, impacts on communication have not been widely reported. This...Full Text Available
Methods of acidizing a subterranean well formation, acidizing compositions, and sequestering additives for preventing the precipitation of metal compounds in the formation are described. Use of the methods and chemicals described should lead to improved formation permeability as compared to use of previous methods and chemicals. 12 claims.
There is increasing concern for the potential adverse health effects of human exposures to chemical mixtures. To better understand the complex interactions of chemicals within a mixture, it is essential...Full Text Available
Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.
Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).
The aortovenous fistulas are rare, most of them are aortocaval fistula. The non-caval communication of the fistula is sparse. Herein we report a 47-year-old female diagnosed as traumatic aorto-superior mesenteric vein (Ao-SMV) fistula. The abdominal pain, fullness, and frank bruit on abdominal auscultation suggested the diagnosis of an intra-abdominal arteriovenous fistula. The diagnosis of Ao-SMV was further confirmed by the computed tomography (CT) and aortography. The fistula was successfully treated with transcatheter coil embolization. This is the first case of Ao-SMV fistula. It provides an alternative option of treatment other than conventional surgery. PMID:19327940
As a consequence of the expanded use of long term hemodialysis and continuous ambulatory peritoneal dialysis (CAPD) treatments and extended life spans, complications of end-stage renal disease and dialysis treatments are being encountered with increasing frequency in these patients. Computed tomography can accurately depict many of the potential complications of end-stage renal disease on dialysis. This article presents the abdominal CT findings of 429 end-stage renal disease patients who are on either hemodialysis or continuous ambulatory peritoneal dialysis treatment.
The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.
To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. ...
Roentgenological analysis of the anterior chest wall was performed in twenty six patients with sternocostoclavicular hyperostosis. Initial hyperostotic change was seen at the first costosternal junction with ventral protrusion. Hyperostosis gradually developed around the first ribs, and irregular hyperostotic changes were also seen along the costoclavicular ligaments. Even in the final stage, however, sternoclavicular joint spaces were well preserved. These findings suggest that sternocostoclavicular hyperostosis is a disorder initiated around the costal cartilage including the periosteum and perichondrium, and that arthritis is not a condition stemming from that disorder.
The activities and results of a Small Business Innovation Research Phase II project entitled ''Rapid Tools for Joint Inversion and Imaging'' are presented. Research and development on three-dimensional methods to recover distributions of material property values from sparse data are reported. Innovations using artificial neural networks and extended Kalman filtering are described. The report also covers investigations on upscaling and downscaling, segmentation for data processing, and applications to ground penetrating radar and geohydraulic tomography.
The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.
To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)
Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.
Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
The paper investigates the yield and the role of the computerized tomography in diagnosing abdominal gunshot wounds, with their rich and varied radiological signs and associated injuries, and subsequently used in the diagnosis. [Italian] Scopo del lavoro e' riportare l'esperienza personale nell'uso della tomografia computerizzata per riconoscere le lesioni da arma da fuoco dell'addome e nelle fasi successive dell'approfondimento diagnostico.
A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.
Dilatation of the azygos vein is usually due to increased pressure or flow, rarely is it diopathic. Another cause is so-called continuation of the azygos in cases of absence of the hepatic segment of the inferior vena cava. The method of choice for the investigation of azygos dilatation nowadays is computer tomotgraphy. Anomalies of the inferior vena cava can be recognised in this way unequivocally by a non-invasive method. Computer tomography frequently shows important additional abnormalities (e.g. situs inversus, polysplenia), since it demonstrates all organs situated in the plane of section. (orig.).
Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.
During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.
A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)
For better understanding and proper use of organic chemicals addition data are needed, including kinetic data on the scavenging reactions in actual cycles, data on ambient temperature stability and decomposition, sampling and analsyis information, data on effects in a case of fire, and more corrosion data. Use of these chemicals for layup of boilers and other equipment needs to be evaluated for each application. After a preliminary evaluation, such as outlined in this report, every new water treatment chemical should be evaluated in at least two month test in actual steam cycle. (orig.).
Atmospheric pressure plasma enhanced chemical vapour deposition system is built. The electrical and optical characteristics of the APPECVD system is given. The system is used to deposit conductive polymers and nano composites onto glass and metal surfaces. The morphological, optical, chemical and electrical characteristics of deposited surfaces are investigated using SEM, AFM four probe deposition purposes. The photovoltaic applications of plasma deposited polymers and nonconsumption are compared with deposited with electrochemical methods show different results. The electrical, chemical and morphological structures of the samples will be given.
Several possibilities of the use of molecular models in quantum-chemical investigations of the structure of defect centers on the surfaces of oxides on nontransition elements have been illustrated. There has been a special discussion of the assumption of the local nature of the chemical interactions in these systems, which underlies such an approach, and of the consequent laws governing the formation of their lattices in the example cases of zeolites, kaolinites, and comparable boron- and aluminum-containing oxides. A quantum-chemical interpretation of the body of experimental data from investigations of the dehydroxylation of H forms of zeolites has been given. The structure of the Lewis acid centers formed as a result, and their chemisorption properties, have been discussed.
The brochure contains information about the Emergency Planning and Community Right-to-Know Act. This law establishes a structure at the state and local levels to assist communities in planning for chemical emergencies and requires facilities to provide information on various chemicals present in the community. The Act requires that this information be made available to the public. One of the requirements concerns the reporting of annual releases of toxic chemicals to the air, water, and land. These provisions are outlined in Section 313 which mandates annual release reporting for over 300 chemicals.
The effects of variable hardness, pH, alkalinity, humics, and suspended clay on the chemical speciation of copper and its toxicity to fathead minnow larvae in Lake Superior water were investigated. Two proposed methods (toxicity factors and chemical speciation) for predicting LC50 values in specific natural waters from laboratory toxicity data and the average site specific values of general water quality parameters were evaluated. The accuracy of the cupric ion-selective electrode in determining CU/sup +2/ activities in ambient and chemically altered Lake Superior water was also determined.
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
A historical background is first given in which the role of biomass is described in relation to its competition with fossil biomass for the production of chemicals and energy. Occurrences of reserves from both sources are then compared. Petrochemical and biomass routes are then analyzed in terms of their relative competitive advantages. The oleochemical and biotechnology cases are analyzed in more detail as examples of biomass utilization. Latin American examples of industrial manufacturing of biomass derived chemicals are then provided. Alcochemicals are analyzed in detail as well as essential oils and other chemicals. Finally, references are made to regional Latin American initiatives regarding biomass and the objectives, organization and nature of the initiative are presented.
Development of a Comprehensive Decontamination Database and an Absorption-Electrochemical Metal Surface Decontamination Technique Combining Chemical and Electrochemical Process
Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been ...
Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computed tomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose (FDG)-PET for screening asymptomatic individuals and current modalities appear better suited ...
The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. After subdividing subsurface into triangular element we shoot off the ray into subsurface by the Snell`s law. And then after taking the ray path which is similar to proper assumption we can calculate travel time. With this new ray tracing ...
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the ...
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...
Computerized tomography-guided neurolytic splanchnic nerve block is a technique for relieving abdominal cancer pain; the goal is the alcoholic neurolytic interruption of the sensitive structures in retroperitoneal space. Computerized tomography yields accurate anatomical detailing and the course for needle placement and alcohol spread. January, 1993, to July, 1996, twenty-one bilateral splanchnic nerve blocks were performed through the posterior access. Forty-eight hours after alcoholism. 14 patients (66%) had complete pain regression; 52% of the patients needed no analgesics for 6 to 54 days and only 9 patients (42%) needed another low opioid therapy. Complications included hypotension and diarrhea in all cases. One had a cardiac arrest and diet 8 days after the procedure. There were no other complications. The whole procedure usually lasted 60 min (range: 45 to 90 min). Splanchnic nerve neurolysis is a useful treatment in the patients with ...
The authors investigated the role of Computerized Tomography in guiding fine needle biopsy (FNB) in small (2 2 cm in diameter for CT-guided FNB sensitivity, specificity and diagnostic accuracy. Cytologic specimens were positive for malignancy in 40/52 cases (76.9%) and negative in 12 (23.1%). Clinical-surgical follow-up confirmed all the positive cytologic findings (40 cases), while 2 of the extant 12 cases were false negatives (95.20% sensitivity, 100% specificity and 96.15% diagnostic accuracy). 158 of 195 nodules > 2 cm in diameter and with clinical surgical follow-up (81.3%) were positive for malignancy and 34 were negative (17.43%) (98.75% sensitivity, 97.14% specificity and 98.46% diagnostic accuracy). Pneumothorax occurred in 33 patients (16.5%) with nodules > 2 cm in diameter as a complication of biopsy. Hemoptysis occurred in 15 patients (7.5%). In the whole group of lung lesions, the complications were pneumothorax in 80 patients (4.1%), hemoptysis ...
Theoretical thermodynamical calculations for the ZrO/sub 2/- Al/sub 2/O/sub 3/-SiO/sub 2/ system are given to expose the regions of the most chemically stable products of crystallization. It is established that ceramics on the base of mullite with zircon addition and containing the minimum quantity of glass phase should be preferably used in chemical media containing HCl.
This book examines some of the basic principles behind chemical reactions kinetics. Topics considered include ab initio determination of potential energy for chemical reactions; semi-empirical potential energy surfaces; general theory of reactive scattering: different equation approach; and integral equation approach to reactive scattering.
DescriptionThis project has two independent aims: (1) to investigate the use of struvite as an alternative to chemical P fertilisers and (2) to develop an oligonucleotide microarray to monitor the P status of the potato crop. The UK horticultural and agricultural industries rely on large inputs of phosphate (P) fertilisers to maintain crop yields and quality. However, the use of non-renewable, chemical P fertilisers is unsustainable, and the alternatives to chemical P-fertilisers must be identified as an [continued...
This request is submitted to seek interim approval to operate a Toxic Substances Control Act (TSCA) of 1976 chemical waste landfill for the disposal of polychlorinated biphenyl (PCB) waste. Operation of a chemical waste landfill for disposal of PCB waste ...
Microwaves improve the rate of many chemical reactions either interacting with the solvent, when the reaction is carried out in solution, or with the surface of a solid substrate where a suitable reagent is dispersed (dry chemistry). A few examples of chemical reactions positively affected by microwaves are described: particularly interesting are those concerning polymers and radio-pharmaceuticals.
X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)
Papers presented at a meeting on indoor and outdoor climates on sites polluted with volatile organic chemicals. The papers deal with the subject of evaporation of organic chemicals on the polluted sites in relation to the influence on indoor and outdoor climates. Themes dealt with are diffusion through soils and transport of pollutants from the soil into buildings. (AB).
Occupational and environmental exposure to organic ligands, solvents, fuel hydrocarbons, and polychlorinated biphenyls are linked with increased risk of hematologic malignancies. DOE facilities and waste sites in the U.S. are contaminated with mixtures of potentially hazardous chemicals such as metals, organic ligands, solvents, fuel hydrocarbons, polychlorinated biphenyls and radioactive isotopes. A major goal of this project was to establish linkage between chemical/radiation exposure and induction of genomic damage in target populations with the capability to undergo transformation.
A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.
This book deals specifically with the development of new processes of converting coal into useful chemical feedstocks. The major topic in this volume is the generation of syngas and its catalytic conversion to chemicals via the Fischer-Tropsch synthesis. Describes processes involved in conversion, recent catalytic developments, and the commercially important Sasol process. Also includes chapters on the carbide process and potential of future developments in the field.
Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.
Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).
DescriptionThis project continues DEFRA's commitment to the International Programme on Chemical Safety, a joint WHO/ILO/UNEP programme. DEFRA's contribution involves preparing Environmental Health Criteira Documents (EHCs), Concise International Chemical Assessments Documents (CICADS) and input to the OECD test Guidelines Programme and gneral risk assessment guidance. Peer reviews of documents prepared through other research in the IPCS network have also been carried out,as well as attending and hosting ta [continued...
Most chemical reactions in industry and biology are catalytic and play a role at some stage of the processing of about 80% of the goods manufactured in the U.S., yet catalysis is a neglected subject in chemical education. This book integrates the fragmentary treatment accorded the topic until now. It covers, in a unified way, catalysis in solutions, by enzymes, in synthetic polymers within the molecular scale cages of zeolites and other molecular sieves, and on surfaces of inorganic solids. The central ideas are chemical; and principles are illustrated by emphasizing industrial reactions and catalysts.
Radiosensitization by lactate, pyruvate, nalidixic acid and novobiocin was studied in exponentially growing SH-18L human lung fibroblasts. All the chemicals had a slight radiosensitizing effect at a low concentration and a definite effect at a higher one. Decreases in the D_0 and/or Dq values were present in each dose survival curve. Fibroblasts incubated with the low concentration of each chemical for 24 hrs after X irradiation showed no reduction in intracellular ATP content, whereas, the higher concentration produced a significant decrease. These observations suggest that the decrease in the ATP content may be involved in the radiosensitization of human fibroblasts at high concentrations of these chemicals. In contrast, radiosensitization at a low concentration is not explained by a relationship to ATP content. Different mechanisms may be involved in radiosensitization at low and high concentrations of these ...
Many higher plants produce economically important organic compounds such as oils, resins, tannins, natural rubber, gums, waxes, dyes, flavors and fragrances, pharmaceuticals, and pesticides. However, most species of higher plants have never been described, much less surveyed for chemical or biologically active constituents, and new sources of commercially valuable materials remain to be discovered. Advances in biotechnology, particularly methods for culturing plants cells and tissues, should provide new means for the commercial processing of even rare plants and the chemicals they produce. These new technologies will extend and enhance the usefulness of plants as renewable resources of valuable chemicals. In the future, biologically active plant-derived chemicals can be expected to play an increasingly significant role in the commercial development of new products for regulating plant growth and for ...
An analysis system for the long-term mechanical behavior of barrier materials (MACBECE: Mechanical Analysis system considering Chemical transitions of BEntonite-based and CEment-based materials) was developed in order to improve the reliability of the evaluation of the hydraulic field which is one of the important environmental conditions in the safety assessment of the TRU waste disposal. MACBECE is the system that calculates the deformation of barrier materials using their chemical property changes as inputs, and subsequently calculates their hydraulic conductivity taking both their chemical property changes and deformation into consideration. By using MACBECE, the long-term deformation and the transition of hydraulic field for the round-type disposal cavities were evaluated, assuming some sets of chemical evolution data as input. Based on the analysis result, it is considered that the influence of ...
Under Section 5 of the Toxic Substances Control Act (TSCA), manufacturers must notify the US Environmental Protection Agency (EPA) 90 days before manufacturing, processing, or importing a new chemical substance. This is referred to as a premanufacture notice (PMN). The PMN must contain certain information including chemical identity, production volume, proposed uses, estimates of exposure and release, and any health or environmental test data that are available to the submitter. Because there is no explicit statutory authority that requires testing of new chemicals prior to their entry into the market, most PMNs are submitted with little or no data. As a result, EPA has developed special techniques for hazard assessment of PMN chemicals. These include (1) evaluation of available data on the chemical itself, (2) evaluation of data on analogues of the PMN, or evaluation of data on ...
We performed density functional calculations to examine the effects of solvation, hydrogen bonding, backbone conformation, and the side chain on 15N chemical shielding in proteins. We used N-methylacetamide (NMA) and N-formyl-alanyl-X (with X being one of the 19 naturally occurring amino acids excluding proline) as model systems. In addition, calculations were performed for selected fragments from protein GB3. The conducting polarizable continuum model was employed to include the effect of solvent in the density functional calculations. Our calculations for NMA show that the augmentation of the polarizable continuum model with the explicit water molecules in the first solvation shell has a significant influence on isotropic 15N chemical shift but not as much on the chemical shift anisotropy. The difference in the isotropic chemical shift between the standard ?-sheet and ?-helical conformations ranges ...
Current regulations guiding technical aspects of natural resource damage assessments combine source, exposure pathway, resource injury, and monetary damage components. In order to associate any observed injury to the uncontrolled release of chemicals (e.g. oil spills, contaminated sediments, in-place toxics, etc.), it is important to link the chemical ''release'' to the injured resource. In complex environmental settings where multiple sources of similar chemicals are combined, multicomponent chemical methods must be used to link the release to the environmental distribution of chemicals. Three examples of the utility of multicomponent organic chemical analyses linked to comprehensive and representative sampling strategies will be discussed--the Shell Martinez Refinery oil spill, the Exxon Valdez oil spill, and a contaminated sediment assessment. These ...
Investigations were made on the biodegradability and bacterial toxicity of chemicals. The intention was to obtain data necessary for estimating and judging the behaviour of these chemicals during aerobic biological waste water treatment. The course of biodegradation and toxicity with time and concentration could be measured, quantified and described. As test procedure, the respirometric dilution method was used. This method is based on a die away test with continuous measuring of the oxygen used for biochemical oxidation processes. The course of the oxygen demand with time and concentration shows the biodegradation and toxicity patterns of the tested chemical. A variety of household and industrial chemicals were investigated. One group of substances were microbiocides, some of which showed toxic effects at concentrations less than 20 mg/l while others were biodegradable even at concentrations of 200 ...
In this work we present an ultra-low temperature method for the oxidation of an amorphous silicon-carbide-nitride (SiCN) material. The SiCN is deposited on silicon substrates by plasma enhanced chemical vapor deposition using CH{sub 4}, SiH{sub 4}, and N{sub 2} chemistry. The physical and chemical properties are characterized for the as-deposited SiCN and post-oxidized films are discussed. The SiCN film is exposed to oxygen plasma, where it undergoes a chemical transformation into a binary SiO{sub 2} material system. A 1.7 nm/min oxidation rate is typical for this process and compares favorably to oxidation methods utilizing much higher temperatures. The substrate temperature remains extremely low throughout the oxidation process, T{sub s} < 200 deg. C. Changes in film stress, optical constants, film thickness, surface roughness, and film density are measured. Chemical analysis by X-ray ...
The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with significant accuracy. Several ...
Current information on the use of ionizing radiation for improving the storage of subtropical fruits like citrus, grapes, and avocados is reviewed. The feasibility of applying radiation either alone or in combination with other physical or chemical treatments for the control of postharvest fungal diseases is considered. Irradiation effects on the physiology of the fruits as related to respiration, ethylene evolution, changes in major chemical constituents, and quality are discussed. The recent trends in the possible use of irradiation as an alternative treatment to chemical fumigants for disinfestation of citrus and avocados and the prospects for the future application of irradiation for preservation of some of these fruits are outlined. 128 references.
This book provided a set of supplementary papers provided to delegates at the eighth international CANMET/ACI conference on superplasticizers and chemical admixtures in concrete. Recent research on chemical admixtures and superplasticizers was presented along with new approaches to the practical application of concrete admixtures. The presentations highlighted technological advances in the development of superplasticizers and new approaches to the manufacture and implementation of aggregates. Issues regarding the application of plasticizers with various aggregates were addressed, and interactions between cements and superplasticizers were evaluated. Four of the supplementary papers have been catalogued separately for inclusion in this database. refs., tabs., figs.
Biosorption is an important removal mechanism in treating hydrophobic toxic organics in biological reactors. Equilibrium sorption isotherms and sorption kinetics of 2,4-dichlorophenol on live and chemically inactive anaerobic granules were studied. A metabolic inhibitor was used to inactivate the biological activity of the biomass. Results showed that the difference in the biosorption of live and chemically inactive anaerobic granules is not significant. This would suggest that anaerobic biosorption is mainly a physical-chemical process and that metabolic-mediated diffusion in the process is negligible. 12 refs., 3 tabs., 7 figs.
A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.
An independent chemical compatibility review of various wrapping and absorbent/padding materials was conducted to evaluate resistance to chemicals and constituents present in liquid waste from the Hanford underground tanks. These materials will be used to wrap long-length contaminated equipment when such equipment is removed from the tanks and prepared for transportation and subsequent disposal or storage. The materials studied were Cooley L18KU, Herculite, and Elephant Mat. The study concludes that these materials are appropriate for use in this application.
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.
Chest computed tomography (CT) was valuable in detecting extrinsic tracheal compression by mediastinal masses in two pediatric patients. This prompted an independent evaluation by CT of 14 children with masses involving the middle mediastinum and possible intrathoracic tracheal narrowing. Computer programs permit precise calculation of tracheal cross-sectional areas. Any apparent decrease in tracheal area may be compared with CT-derived data in normal children. Chest CT not only demonstrates the presence of extrinsic airway compression in pediatric patients with mediastinal masses, but also is capable of precisely measuring the extent of this narrowing. This method identifies children at potential risk for respiratory compromise and may aid in subsequent therapy.
The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).
Rationale Receptor occupancy study has been performed to evaluate pharmacokinetic profiles in new antipsychotic drug development. While these findings highlight the value of positron emission tomography (PET) for dose-finding study, what is unclear is if it is necessary to conduct these studies in patients with schizophrenia or whether studies in healthy volunteers are adequate. Objectives To determine if it is necessary to conduct dopamine receptor occupancy studies in patients with schizophrenia or whether studies in healthy volunteers are adequate for dose-finding study, we compared the concentration?occupancy relationship in terms of EC50 between patients and healthy volunteers. Methods Ten healthy volunteers and eight patients with schizophrenia participated in the study. We measured ...
Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward.
The aims of this study were to quantify the severity and extent of subclinical interstitial lung disease as depicted on HRCT and to study the relationship between the patterns of lung disease quantified by HRCT and the functional parameters and bronchoalveolar lavage findings in patients with rheumatic diseases. The results confirm that HRCT is a sensitive tool in detecting interstitial lung disease in patients with rheumatic diseases with no signs and symptoms of pulmonary involvement. The relationship between the different HRCT patterns and bronchoalveolar lavage cell profiles can identify patients at higher risk of developing irreversible lung fibrosis. A long-term, prospective follow-up study is needed to determine whether these patients will develop over pulmonary disease.
We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low striatal activity, ...
In spite of the improved imaging techniques currently available, mortality for pancreatic cancer is still high, and pancreatics is often diagnosed only in its advanced stages. The authors investigated the value of different imaging techniques - i.e., US, CT, and ERCP - for an early diagnosis, when a more effective (curative?) treatment can be suggested. Fifty-six cases of pancreatic cancer and 36 cases of chronic pancreatitis were evaluated. The results indicate that ERCP, with the help of statistical methods, is superior to US and CT not only in evaluating early neoplastic or inflammatory lesions, but also for their differential diagnosis. In the letter case, ERCP can sometimes be used as a valid alternative to fine-needle aspiration biopsy.
Abstract Many solute carrier transporters that interact with anticancer agents and contribute to their pharmacokinetics have been shown to be differentially upregulated in cancer cells as a result of adaptive response to altered nutritional requirements. This review focuses on pathophysiological function of membrane transporters responsible for the influx of physiological substances including oligopeptides, amino acids, and organic cations and anions, and summarizes the recent knowledge regarding mechanisms in their gene expressions. Broad substrate specificity of enhanced oligopeptide H+/peptide cotransporter 1 activity in cancer cells is useful for tumor tissue-specific delivery of chemotherapeutic agents and positron emission tomography diagnostic probes. Amino acid transporters such as...
Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).
For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).
A series of four 125I-labeled 1-substituted-4-phenylpiperazines were prepared and evaluated in rats as potential brain imaging agents. The compounds were labeled using (125I)iodide/chloramine-T or iodine monochloride and isolated in 48-60% radiochemical yields. The tissue distribution studies indicated that a butyrophenone derivative demonstrated the best overall brain-imaging properties. Compared with the compounds having other 1-substituents this agent had a more prolonged retention of activity in the brain and higher brain-to-blood ratios over the 4-h period studied. The in vivo behavior of this agent is comparable to that of radioiodinated N-isopropyl-p-iodoamphetamine, and, because it can be labeled directly via electrophilic methods, it has substantial potential for use in brain imaging with single photon emission computed tomography.
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the exposed region from the ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the exposed region from the ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the exposed region from the ...
Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).
SummaryPermeable pavement functions as a porous infrastructure interface allowing the infiltration and evaporation of rainfall-runoff while functioning as a relatively smooth load-bearing surface for vehicular transport. Hydraulic conductivity (k) of permeable pavement is an important hydraulic property and is a function of the pore structure. This study examines k for a cementitious permeable pavement (CPP) through a series of pore-structure models. Measurements utilized include hydraulic head as well as total porosity, (t), effective porosity (e), tortuosity (Le/L) and pore size distribution (PSD) indices generated through X-ray tomography (XRT). XRT results indicate that the permeable pavement pore matrix is hetero-disperse, with high tortuosity and t!=e. Power law models of k-t and k-e...
PurposeTo evaluate pathologic features of the photoreceptors in myopic foveoschisis with the Fourier-domain optical coherence tomography (FD-OCT).DesignObservational case series.MethodsSeventeen eyes of 15 patients with myopic foveoschisis (foveal detachment type, six eyes; foveoschisis type, 11 eyes) were included. We observed the photoreceptor inner and outer segments (IS/OS) and evaluated the morphologic status using FD-OCT. Fundus photographs and time-domain OCT (TD-OCT) images also were obtained.ResultsIS/OS defects, which are uncommon in retinal detachments in eyes with myopia, were seen clearly in five eyes (three eyes [50%] with the foveal detachment type; two eyes [18%] with the foveal schisis type). Fundus photographs showed myopic chorioretinal atrophy in eight study eyes (47%),...
Noninvasive prediction of vertebral body strength under compressive loading condition is a valuable tool for the assessment of clinical fractures. This paper presents an effective specimen-specific approach for noninvasive prediction of human vertebral strength using a nonlinear finite element (FE) model and an image based parameter based on the quantitative computed tomography (QCT). Nine thoracolumbar vertebrae excised from three cadavers with an average age of 42 years old were used as the samples. The samples were scanned using the QCT. Then, a segmentation technique was performed on each QCT sectional image. The segmented images were then converted into three-dimensional FE models for linear and nonlinear analyses. A new material model was implemented in our nonlinear model being more...
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization system.
An ultrasonic signal processing technique is applied to multi-mode arrival time estimation from Lamb waveforms. The basic tool is a simplified time-scale projection called a dynamic wavelet fingerprint (DWFP) which enables direct observation of the variation of features of interest in non-stationary ultrasonic signals. The DWFP technique was used to automatically detect and evaluate each candidate through-transmitted Lamb mode. The area of the dynamic wavelet fingerprint was then used as a feature to distinguish false modes caused by noise and other interference from the true modes of interest. The set of estimated arrival times were then used as inputs for tomographic reconstruction. The Lamb wave tomography images generated with these estimated arrival times were able to indicate different defects in aluminum plates.
Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection of joint diseases using MRT remains to be ...
A 46-year-old man was referred to us after he presented to his local physician complaining of difficulty eating. Upper gastrointestinal endoscopy revealed a tumor at the esophagogastric junction (EGJ), and moderately differentiated adenocarcinoma was diagnosed from the biopsy findings. Computed tomography (CT) showed apparent enlargement of the pretracheal lymph nodes, the lymph nodes around the bilateral recurrent laryngeal nerves, and the lower thoracic paraesophageal lymph nodes, confirming metastasis. Since the disease was far advanced esophagogastric cancer with marked lymph node metastases throughout the mediastinum, curative resection would have been unlikely. Thus, he was commenced on systemic chemotherapy with cisplatin (90 mg/body, day 8) + S-1 (120 mg/body/day, given for 3 weeks...
Abstract Introduction: Transduodenal ampullectomy (TDA) can be performed for benign and premalignant tumors of the ampulla of Vater (AOV) as an alternative to pancreaticoduodenectomy. However, the laparoscopic approach has rarely been attempted. In this report 2 cases of benign ampullary tumor that were treated by totally laparoscopic TDA. Patients and Methods: Case 1 was of a 75-year-old female who was admitted with left knee pain and underwent arthroscopic debridement. On postoperative day 6, she showed elevated levels of alkaline phosphatase, aspirate aminotransferase, alanine transaminase, and gamma-glutamyl transpeptidase, without any other laboratory test abnormality. She had no complaint of abdominal pain, and physical examinations were unremarkable. Computed tomography (CT), magnet...
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)
The clinical use of "1"8F-fluorodeoxyglucose (FDG) positron emission tomography in monitoring anticancer treatment is expanding. At the same time a number of radiotracers aiming to image different aspects of tumour biology such as proliferation and apoptosis are being developed. However, the factors determining changes of radiotracer uptake parameters in response to treatment are not well understood. In many cases, cellularity may be the primary determinant of changes of FDG uptake and may confound the interpretation of metabolic changes. Early imaging assessments have in some cases showed transient increases of uptake parameters, commonly termed 'flares', which are likely to be unaffected by cellularity and directly reflect pharmacodynamics at a cellular level. In this review a number of settings where molecular imaging 'flares' have been described are discussed. Such changes may often be clinically informative and warrant careful study as potential predictive ...
Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...
Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might be made while the patient is still under observation rather ...
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper summarize the practice of the standards passed over the past one year, which ...
Abstract Studies of the megamouth shark, one of three planktivorous sharks, can provide information about their evolutionary history. Megamouth shark feeding has never been observed in life animals, but two alternative hypotheses on biomechanics suggest either feeding, i.e., ram feeding or suction feeding. In this study, the second moment of area of the ceratohyal cartilages, which is an indicator of the flexural stiffness of the cartilages, is calculated for 21 species of ram- and suction-feeding sharks using computed tomography. The results indicate that suction-feeding sharks have ceratohyal cartilages with a larger second moment of area than ram-feeding sharks. The result also indicates that the ram-suction index, which is an indicator of relative contribution of ram and suction behavi...
Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, microwave technology, cryogenics, vacuum technology, special ...
A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192
This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...
Active contrast material extravasation can be recognized with conventional CT scanners, though it has been considered a rare finding. Helical CT seems to increase the detection rate and especially to boost the radiologist's confidence in this diagnosis. Though active bleeding is defined in severely-injured subjects requiring urgent intervention and may be associated with findings of hypovolaemic shock, it should not be considered itself as a negative prognostic factor. Contrast extravasation is due to ongoing hemorrhage and its detection is critical for urged treatment. Accurate anatomical location permits to choose surgical management or transcatheter embolization and thus decreases time consumption for precis e bleeding site identification.
In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.
The growth of a middle ear cholesteatoma behind a normal tympanic membrane is a rate though possible event. In such cases, CT may provide useful information for diagnosis. The results are presented of a CT study carried out on 14 patients affected with unilateral conductive hearing loss and with normal tympanic membrane. CT allowed the diagnosis of meddle ear cholesteatoma to be made in all cases. All patients were treated with surgery: 8 of them underwent tympanoplasty and 6 explorative tympanotomy. While the diagnosis of cholesteatoma was confirmed in 13 patients, in 1 case tympanosclerosis was diagnosed. CT diagnosis of middle ear cholesteatoma is based on the demonstration of a low-density soft-tissue mass, in association with bone erosion or ossicular dislocation. The author emphasizes the difficulty of a CT diagnosis of cholesteatoma in the patients with middle ear soft-tissue masses in the absence of bone alterations.
Abstract Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landma...
In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).
In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).
One of the goals of the DARPA Virtual Soldier Project is to aid the field medic in the triage of a casualty. In Phase I, we are currently collecting 12 baseline experimental physiological variables and a cardiac gated Computed Tomography (CT) imagery for use in an prototyping a futuristic electronic medical record, the "Holomer". We are using physiological models and Kalman filtering to aid in diagnosis and predict outcomes in relation to cardiac injury. The physiological modeling introduces another few hundred variables. Reducing the complexity of the above into easy-to-read text to aid in the triage by the field medic is the challenge with multiple display solutions. A description of the possible techniques follows. PMID:15718701
Aim of the work was to describe computerised tomography (CT) findings of calcified renal metastases focusing on differential diagnosis problems. Abdominal CT scans of 8000 patients with tumor, performed from 1984 to 1998, have been retrospectively reviewed. [Italian] Scopo del lavoro e' quello di descrivere gli aspetti con tomografia computerizzata delle metastasi renali calcificate enfatizzando le problematiche diagnostico differenziali. Sono state valutate retrospettivamente le indagini TC addominali di 8000 pazienti affetti da tumore nel periodo 1984-1998, analizzando le lesioni calcificate riscontrate.
The paper reports the results of a preliminary experience with volume rendering technique of virtual computerized tomography colonoscopy and compares it with endoscopy and surgery showing its capability in detecting colon and rectal cancers. [Italian] Scopo del lavoro e' riportare l'esperienza personale preliminare nell'uso della colonscopia TC virtuale confrontando i risultati con quelli dell'endoscopia e dei riscontri operatori, dimostrandone l'efficacia nella diagnosi delle malattie tumorali del colon-retto.
The facilities in the Institute for Nuclear Research at Pitesti allow the testing, handling and examination of nuclear fuel and irradiated materials. The most important facilities are the TRIGA Steady State Research and Material Test Reactor and the Post-Irradiation Examination Laboratory (PIEL). The purpose of this work is to determine by post-irradiation examination, the behavior of CANDU fuel, irradiated in 14 MW TRIGA reactor. The fuel was irradiated in power ramp conditions. The results of post-irradiation examination are: - Visual inspection and photography of the outer appearance of sheath; - Profilometry (diameter, bending, ovality) and length measuring; - Determination of axial and radial distribution of the fusion products activity by gamma scanning and tomography; - Microstructural characterization by metallographic and ceramographic analyzes; - Mechanical properties determination. The data obtained from the post-irradiation examination are used to ...
Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.
... transItion to more capable space-based interceptors as ... ten wtth bmlogtcal, and thirty with chemical weapons. ... are becoming the weapon of choice ...
The Netherlands Chemical Industry Association (VNCI) is investigating the potential for expansion of the CHP capacity in the Dutch chemical industry. This report discusses the return on investment for CHP installations and the market conditions. Moreover, scenario results are presented for the CHP potential and the development of CHP in the chemical industry until 2020. [Dutch] De Vereniging van de Nederlandse Chemische Industrie (VNCI) heeft onderzoek laten uitvoeren om vast te stellen welke economische en beleidsmatige voorwaarden er zijn om het WKK-potentieel in de Nederlandse chemie te realiseren. Dit rapport brengt de marktpositie van WKK en de rentabiliteit van investeringen in WKK in beeld. Verder worden resultaten gegeven voor de potentiele energiebesparing en emissiereductie en wordt een scenario gepresenteerd voor het WKK-potentieel in de chemische industrie tot 2020.
as manufacturing plants and laboratories, including the Chemical Laboratory at the House of David in Benton Harbor, Michigan. Built in America: Historic Building Buildings Survey/...
... Chem. Res., in press, 2006. 8. Smith, BL, Bruno, TJ, Advanced distillation curve measurement with a model predictive temperature controller. Int. ...
The SCF approximation is used in a statistical theory of melting based on equality of the chemical potentials. The results for the melting points of the inert gases are close to the observed values.
The protocols presently established for optimum seed storage do not account for the chemical composition of different seed species, the physiological status of the seed, and the physical status of water...Full Text Available
The molecular structure, chemical properties, and biological function of the xyloglucan polysaccharide isolated from cell walls of suspension-cultured sycamore (Acer pseudoplatanus)...Full Text Available
Hyaluronan (HA), a non-sulfated glycosaminoglycan, is widely used in the clinic for viscosurgery, viscosupplementation, and treatment of osteoarthritis. Four decades of chemical modification...Full Text Available
other chemical applications include use in water softeners, detergents, and food additives. The development of phosphate resources as a leasable commodity provides income to...
The point at which the common final pathway for induction of cancer by chemical carcinogens and ionizing radiation has not been identified. Although common molecular targets are suggested by recent findings about the role of oncogenes, the mechanism by which the deposition of radiation energy and the formation of adducts or other DNA lesions induced by chemicals affects the changes in the relevant targets may be quite different. The damage to DNA that plays no part in the transformation events, but that influences the stability of the genome, and therefore, the probability of subsequent changes that influence tumorigenesis may be more readily induced by some agents than others. Similarly, the degree of cytotoxic effects that disrupt tissue integrity and increase the probability of expression of initiated cells may be dependent on the type of carcinogen. Also, evidence was presented that repair of the initial lesions could be demonstrated after ...
... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...
Using the radiation chemical method it is possible to prepare wood-plastic composites using doses of 1 to 2.5 kGy. The impregnation mixture in the wood gelatinates and subsequent curing using chemical initiators takes place without outflow of the mixture from the wood and without formation of incrustations. The basic components of the impregnation mixtures used were unsaturated polyester resins; styrene or methyl methacrylate was used as the thinner. The proven initiator of polymerization was 2,2'-azobisisobutyronitrile. The technology is described of wood impregnation and radiation or chemical curing. The effects were monitored of viscosity, temperature, radiation dose and the concentrations of the individual components of the impregnation mixtures and initiators of polymerization on the process of the preparation of wood-plastic composites.
BackgroundBisphenol A (BPA) is a high-production-volume chemical commonly used in the manufacture of polycarbonate plastic. Low-level concentrations of BPA in animals and possibly...Full Text Available
For some neurotoxic chemicals, neurobehavioral effects are now considered to be among the most sensitive end points yet detected, particularly if exposures occur during critical windows of vulnerability....Full Text Available
The OSHA's chemical occupational exposure standard for laboratories is an outgrowth of the previously issued Hazard Communication Standard. The standard relieves laboratories from complying with general industry standards but does not require compliance with specific guidelines. The heart of the standard is the creation of a Chemical Hygiene Plan (CHP) in every laboratory. The CHP addresses major issues such as safety equipment and procedures, work practices and training, the designation of a chemical hygiene officer, and the provision of medical consultation and examination for affected employees. This new standard, in effect as of 31 January, 1991, presents yet another regulatory challenge to laboratory managers but also will ensure a safer work environment for laboratory workers.
NSF-NIST Interaction in Chemistry, Materials Research, Molecular Biosciences, Bioengineering, and ... Laboratory (CSTL). Materials research is centralized in the Materials Science and Engineering ...
Sep 21, 2006 ... NASA has selected Air Products and Chemicals, Inc., Allentown, Pa., to design, furnish and install a plant to produce liquid nitrogen for ...
Vanadium carbide is the most effective grain growth inhibitor for ultrafine WC-Co composites due to its high solubility and mobility in the cobalt phase at relatively low temperatures; however, there are still some debates over the best way to introduce it into the WC-Co formulation. In this paper, the differences between admixed and chemically doped grain growth inhibitors on the microstructural development and properties of an ultrafine WC-10Co composite are discussed. The densification rate of chemically doped samples is slower in the early stage of sintering and the WC grain sizes of the sintered alloys are finer than those of admixed samples, leading to the increase of hardness and transverse rupture strength of the sintered alloys. The effectiveness of the chemically doped inhibitor ...
Immunomodulatory drugs lenalidomide and pomalidomide are synthetic compounds derived by modifying the chemical structure of thalidomide to improve its potency and reduce its side effects. Lenalidomide...Full Text Available
It is known that the plant cuticle represents the first barrier that must be overcome by any chemical reaching the plant surface from the atmosphere before entering the plant. Because of the importance of the cuticle as a barrier to penetration of a wide variety of compounds, its morphology, chemistry, and permeability have been extensively studied. However, only limited information is available on the nature of functional chemical groups present and their interaction and role during the penetration process. The usefulness of in situ Fourier transform infrared spectroscopy studies in identifying functional groups present in isolated cuticles is described and their relationships to the structure of the cuticular membrane are discussed. Applications of infrared spectroscopy on the presence and role of phenolics in the cuticle structure and during the cuticle development, nitrogen oxide binding to isolated cuticles, and the interactions between ...
Techniques for culturing, harvesting, and testing bacteria to evaluate bactericidal chemicals for swimming pools are described. Concentrations of 25, 50, and 100 mg of the chlorine stabilizer cyanuric...Full Text Available
Insect growth regulators (IGRs) are a class of new chemicals that interfere with maturation and reproduction in insects. Proposed hypotheses on the biochemical mechanism of action are presented herein....Full Text Available
The electrical responses of the neurons associated with the various types of chemosensory hairs of the blowfly, Phormia regina Meigen, following stimulation by chemical and mechanical...Full Text Available
A detailed chemical kinetic reaction mechanism is developed to describe incineration of the chemical warfare nerve agent sarin (GB), based on commonly used principles of bond additivity and hierarchical reaction mechanisms. The mechanism is based on previous kinetic models of organophosphorus compounds such as TMP, DMMP and DIMP that are often used as surrogates to predict incineration of GB. Kinetic models of the three surrogates and GB are then used to predict their consumption in a perfectly stirred reactor fueled by natural gas to simulate incineration of these chemicals. Computed results indicate that DIMP is the only one of these surrogates that adequately describes combustion of GB under comparable conditions. The kinetic pathways responsible for these differences in reactivity are identified and discussed. The most important reaction in GB and DIMP that makes them more reactive than TMP or DMMP is found to be a ...
The values of X = 0.77, Z = 0.035, and Y = 0.195 and the stage of evolution of Procyon are determined from the evolutionary tracks and the results of an analysis of the chemical composition of the atmosphere.
The biosynthesis of insect juvenile hormone (JH) and its neuroendocrine control are attractive targets for chemical control of insect pests and vectors of disease. To facilitate the molecular...Full Text Available
The influence of chemical and solvent extraction compatibilising techniques on the mechanical properties of poly-lactic acid (PLA) and MaterBi-polyester (PEM) based bio-composites are compared. First, fibres were chemically grafted with two fatty chains: stearic anhydride and octadecylisocyanate. Grafted fibres were characterised by FTIR and elemental analyses. Contact angle measurements show the hydrophobisation of the fibres in spite of very low surface grafting. Extracted and non-grafted fibres were prepared to be used as references. PEM and PLA-based composites with 30% w/w were prepared by compression moulding. Their mechanical properties were studied. It was found that chemical and solvent treatment of the fibres improved the reinforcement effect in the case of a PEM matrix and the Y...
Tri layer hybrid composites of oil palm empty fruit bunches (EFB) and jute fibres was prepared by keeping oil palm EFB as skin material and jute as the core material and vice versa. The chemical resistance, void content and tensile properties of oil palm EFB/Jute composites was investigated with reference to the relative weight of oil palm EFB/Jute, i.e. 4:1, the fibre loading was optimized and different layering pattern were investigated. It is found from the chemical resistance test that all the composites are resistant to various chemicals. It was observed that marked reduction in void content of hybrid composites in different layering pattern. From the different layering pattern, the tensile properties were slightly higher for the composite having jute as skin and oil palm EFB as core ...
Chemical characterization of passive films formed on AISI 304 austenitic stainless steel, in a borate/boric acid solution at pH 9.2, under various conditions of potential, temperature, and polarizations time, was made by Auger electron spectroscopy combined with ion sputtering, and x-ray photoelectron spectroscopy (XPS). The depth chemical composition, thickness, and duplex character of the passive layers were determined after processing AES sputter profiles by their quantitative approach based on the sequential layer sputtering model. Moreover, separated contributions of elements in their oxidized and unoxidized state could be disclosed from part to part of the oxide-alloy interface. The XPS study specified the chemical bondings which take placed inside the film, between Fe and oxygen (and water).
ABSTRACT We present evidence that differences in soil seedbank persistence among pioneer plants in the cloud forest of Monteverde, Costa Rica, are influenced by differences in seed chemical defense. We used extracted seed chemicals from Bocconia frutescens (Papaveraceae), Guettarda poasana (Rubiaceae), Phytolacca rivinoides (Phytolaccaceae), Urera elata (Urticaceae), Cecropia polyphlebia (Cecropiaceae), and Witheringia meiantha (Solanaceae) to assess seed chemical defense in two ways: (1) a plant pathogen inhibition assay using Pythium irregulare; and (2) a brine shrimp toxicity assay using Artemia salina. The combined performance of each species in the two assays positively correlated with seedbank persistence. In the pathogen assay, mycelium growth was reduced when Pythium was cultured o...
A brief review of standard big bang nucleosynthesis theory and the related observations of the light element isotopes is presented. Implications of BBN on chemical evolution and constraints on particle properties will also be discussed.
An idea whose time has come takes center stage in London this week when BP Chemicals announces details of a consortium of chemical companies joining it in a new recycling project. In the project, which BP has been working on since 1989, waste plastic will be depolymerized to chemical feedstocks, via technology variously called feedstock or chemical recycling, polymer cracking, or tertiary recycling. BP's effort is one of the first to emerge from the research and pilot-plant stages that are committed to actual feedstock recycling of mixed polyolefins and other plastics. But it is only one of the many industry efforts under way to cope with the job of dealing with postconsumer plastics.
A method and apparatus for determining the condition of tissue or otherwise making chemical identifications includes exposing the sample to a light source, and using a synchronous luminescence system to produce a spectrum that can be analyzed for tissue condition.
Chemically reactive compounds in tissues can be monitored through their products of reaction with biomacromolecules. For the purpose of in vivo dose monitoring, hemoglobin (Hb) has been preferred to...Full Text Available
A phenomenon based model for chlorine dioxide delignification of chemical pulp is introduced. The pulp suspension environment is modeled using the concept of two liquid phases, one inside and the other external to the fiber wall. Physico-chemical processes taking place during delignification are implemented with thermodynamic, mass transfer and reaction kinetic models. A broad library of chemical reactions is introduced. Inclusion of each reaction is justified. The model response is tested against experimental laboratory delignification results (o-delignified birch pulp). The experimental data consists of kappa number, hexenuronic acid, inorganic oxy-chlorine compound, and organochlorine (AOX, OX) measurements at several time points during five delignification experiments. The model predic...
We present a technique for identifying the amino acids responsible for a loss of immunoreactivity in response to treating an antigen with a chemical modifier. This is of particular interest...Full Text Available
Reflection tomography allows in theory the determination of the velocity distribution and the reflector geometries in the subsurface from the travel times of the seismic waves. The solution of the inverse problem is the model (velocity distribution and reflectors) that minimizes the misfits between observed travel times and travel times computed by raytracing (the forward problem). Two representations of the velocity field are generally used: blocky models (discontinuous) and smooth models. The object of this thesis is the study of tomography with smooth models which offer interesting properties at a practical level as well as at a mathematical and numerical level. We propose an original formulation of the inverse problem which allow the integration of a priori information adapted to smooth models. This formulation assures the existence, the uniqueness and the stability of the solution of the linearized inverse problem. The non-linear inverse ...
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake ...
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent ...
Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through the ethmoidal (70%) and ...
Visualization of falx cerebral on non-enhanced computer tomography (CT) of children with severe head injuries (the falx sign) has been regarded as an evidence of subarachnoid hemorrhage. On the contrary, other authors have reported reverse results. To evaluate clinical significance of the falx sign, authors studied frequency of visualization and CT number of falx cerebri and dural sinuses in 65 children with head injury and 65 children without head injury examined by cranial computer tomography at the Department of radiology, St Paul's Hospital, Catholic Medical College from March to September, 1981. All patients with head trauma were studied within 1 week of the traumatic event. Visualization of falx cerebri was observed at slice in the region of lateral ventricle and slice near to vertex respectively. On the slice in the region of lateral ventricle, falx cerebri was identified in 82% of all of the children examined, of which 92% ...
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger neutron flux (7.3 x 10[sup 7] n/cm[sup 2]/s) ...
It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and ...
Accurate modeling of system response and scatter distribution is crucial for image reconstruction in emission tomography. Monte Carlo simulations are very well suited to calculate these quantities. However, Monte Carlo simulations are also slow and many simulated counts are needed to provide a sufficiently exact estimate of the detection probabilities. In order to overcome these problems, we propose to split the simulation into two parts, the detection system and the object to be imaged (the patient). A so-called 'virtual boundary' that separates these two parts is introduced. Within the patient, particles are simulated conventionally. Whenever a photon reaches the virtual boundary, its detection probability is calculated analytically by evaluating a multi-dimensional B-spline that depends on the photon position, direction and energy. The unknown B-spline knot values that define this B-spline are fixed by a prior 'pre-' simulation that needs to be run once for each ...
Positron Emission Tomography (PET) was used to analyze in vivo antagonist binding to human myocardial muscarinic cholinergic receptor. The methiodide salt of the muscarinic antagonist, quinuclidinyl benzilate (MQNB), was labeled with the positron emitter, Carbon-11, and injected intravenously to 8 normal subjects. /sup 11/C-MQNB concentration was determined in vivo in the ventricular septum from 40 cross-sectional images acquired at the same transverse level over a period of 70 minutes. In 4 subjects, various amounts of unlabeled atropine were rapidly injected at 20 minutes to study whether atropine competitively inhibited MQNB. The kinetics of binding of /sup 11/C-MQNB were not the same in vivo and in vitro. The apparent dissociation rate of /sup 11/C-MQNB in vivo was much slower (by 1 to 2 orders of magnitude) than that observed in vitro with /sup 3/H-QNB. After atropine injection, /sup 11/C-MQNB dissociated from its binding sites at a rate that apparently ...
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture ...
Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ...
Surface wave tomography method based on analysis of ambient noise is widely used during the last decade. It is assumed that correlated component of noise is composed of surface waves generated by sources distributed over the Earth's surface more or less uniformly. In such a case the cross-correlation function (CCF) at two stations may be considered as the Green's function of surface wave. This function should be symmetric relatively to zero time. However analysis of CCF at the stations located at the East-European Platform shows that as a rule CCF is characterized with a strong asymmetry. Since "purered noise cannot be extracted from seismic records due to superposition of earthquake signals, the method for calculation of CCF includes amplitude normalization for suppression of earthquakes that reduces signals from earthquakes to a noise level. The parts of records containing waves from earthquakes are neglected because of their short duration. Present study shows ...
Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant GTV-t shrinkage ...
Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to second-order branches. ...
The cavum septum pellucidum is an anatomical variants of the septum pellucidum, and lying between two lateral ventricles and this is referred to as the fifth ventricle. Occasionally, posterior extension of the cavum septum pellucidum towards the splenium is seen and this is known as the cavum vergae, or sixth ventricle. The septum is double membrane and occasionally a narrow cavity containing CSF is present between these membrane. The roof of the cavum septum pellucidum is formed by the corpus callosum and its floor by the anterior pillars of the fornix. This cavum outlined with air is occasionally seen in the pneumoencephalography. Brain CT scans of 1000 patients were performed, and the diagnosis could be made on the basis of the characteristic shape, density and location. Other diagnostic procedure are not necessary in these cases. Patients were examined with CT scanner from June-80' to Dec-80', at department of radiology, Maryknoll Hospital, and 13 cases were ...
Pulmonary infections and tumors are a major cause of death in patients with AIDS. The combination of clinical, radiological, laboratory, and pathohistological data helps to narrow the spectrum of differential diagnoses or even allows a specific diagnosis in many patients. Nevertheless, an accurate diagnosis should be obtained as soon as possible during the clinical course of the illness to initiate treatment in time. Computed tomography (CT) has proven to provide promising results in the diagnosis of AIDS-related throacic diseases. The aim of this paper was to demonstrate the diagnostic capacities of CT in the context of particular AIDS-related thoracic pathologies. Additional information on the spectrum of pathological agents and on differential diagnostic signs is summarized. (orig.) [Deutsch] Pulmonale Infektionen und Tumore sind eine wesentliche Todesursache bei Patienten, die am erworbenen Immunmangelsyndrom AIDS leiden. In den meisten Faellen gelingt es, ...
The authors carried out a retrospective study on 4 years' work on a series of patients with proved active tuberculosis examined in the Departments of Bronchopneumology and Infectious Disease of the Arezzo Civil Hospital. The population was heterogenerous from the immunologic viewpoint. This paper compared the effectiveness of Computed Tomography (CT) with that of conventional chest radiography (CR) in the diagnosis and prognosis of tuberculosis. All patients underwent chest CR in double projection and conventional CT studies of the chest; 16 patients were also submitted to high resolution CT (HRCT). Consolidation was the most frequent parenchymal lesion in immunocompetent patients; it was often associated with cavitation, with no clear topographic prevalence in the upper lobes. Pleural effusion, as the only sign of disease and with empyema features, was found in 10 immunocompetent patients. No predominant pattern was found in the other two groups, even though ...
The aim of this study was to compare multidetector-row computed tomography (MDCT) findings between cases of sclerosing cholangitis with autoimmune pancreatitis (SC-AIP) and infiltrative extrahepatic cholangiocarcinoma (IEC). We retrospectively assessed MDCT findings from 16 IEC cases and 13 SC-AIP cases. MDCT findings were analyzed with regard to location, length, wall thickness, contour, stricture wall enhancement pattern, proximal duct diameter, and the presence of diffuse concentric thickening in the proximal duct and gallbladder wall thickness. Stricture length, stricture wall thickness, and proximal duct diameter were significantly smaller for SC-AIP than for IEC: 19.3#+-#8.7 vs. 31.8#+-#12.0 mm (P=0.004), 2.1#+-#1.3 vs. 4.1#+-#1.3 mm (P<0.001), and 9.2#+-#3.9 vs. 13.3#+-#5.0 mm (P=0.012), respectively. SC-AIP was correlated with stricture location in both the intrapancreatic and hilar hepatic bile ducts, concentric stricture contour (P<0.001), and ...
Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried out in 14 cases and ...
Although silicosis has been studied extensively, the mechanism is still not fully understood. Experiments do provide evidence that the actions of unique properties of silica surface on the cell membrane are the starting point of silicotic processes. This paper summarizes literature on chemical properties of silica surface, and the effect of particle size on silica toxicity. This paper also discusses the ways in which silica dusts are though to interact with the cell membrane, with emphasis on freshness, hydrogen bonding, and free-radical interactions.
The method of spectral disentangling has now created the opportunity for studying the chemical composition in previously inaccessible components of binary and multiple stars. This in turn makes it possible to trace their chemical evolution, a vital aspect in understanding the evolution of stellar systems. We review different ways to reconstruct individual spectra from eclipsing and non-eclipsing systems, and then concentrate on some recent applications to detached binaries with high-mass and intermediate-mass stars, and Algol-type mass-transfer systems.
A method for the chemical modification of the initial structure of humic acids by acylation with indole-3-acetic acid chloride was developed to increase the biological activity of preparations based on peat and lignite humic acids. The plant growth stimulating effect and the antibacterial activity of the synthesized humic preparations were studied.
The goal of the invention is to increase the effectiveness of the isolation process through increasing the waterproofing of the stratum. The cited goal is achieved by isolating water influx into a well through introduction of a chemical reagent into the stratum. To interact with the stratum, an alloy of titanium and iron is introduced into the stratum as the chemical reagent with subsequent pumping of hydrogen into the stratum at 100 to 200C.