WorldWideScience
 
 
2

Improved quadrant anode image sensor with microchannel plates  

Energy Technology Data Exchange (ETDEWEB)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-15

3

An improved quadrant anode image sensor with microchannel plates  

International Nuclear Information System (INIS)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).

1987-11-01

4

An improved quadrant anode image sensor with microchannel plates  

Science.gov (United States)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-01

5

Nano-engineered PtVFe catalysts in proton exchange membrane fuel cells: Electrocatalytic performance  

International Nuclear Information System (INIS)

Proton exchange membrane fuel cells (PEMFCs) are attractive because of their high conversion efficiency, low pollution, lightweight, and high power density. A major area of challenges is the design and engineering of active, robust, and low-cost electrocatalysts. This report discusses recent findings of our investigations of the design and nano-engineering of platinum-vanadium-iron catalysts for use in PEMFC. The membrane electrode assembly was prepared using nano-engineered PtVFe nanoparticles with controlled composition and size supported on carbon as cathode electrocatalysts. The electrocatalytic activity and stability of the catalysts have been characterized by both rotating disk electrode and membrane electrode assembly measurements. The trimetallic catalysts have been shown to exhibit excellent electrocatalytic performance in PEMFC in comparison with commercial platinum catalysts. The results exhibited a good agreement between obtained ...

2010-11-30

6

Pressure drop and heat transfer characteristics of boiling water in sub-hundred micron channel  

Energy Technology Data Exchange (ETDEWEB)

The current work focuses on the pressure drop, heat transfer and stability in two phase flow in microchannels with hydraulic diameter of less than one hundred microns. Experiments were conducted in smooth microchannels of hydraulic diameter of 45, 65 {mu}m, and a rough microchannel of hydraulic diameter of 70 {mu}m, with deionised water as the working fluid. The local saturation pressure and temperature vary substantially over the length of the channel. In order to correctly predict the local saturation temperature and subsequently the heat transfer characteristics, numerical techniques have been used in conjunction with the conventional two phase pressure drop models. The Lockhart-Martinelli (liquid-laminar, vapour-laminar) model is found to predict the two phase pressure drop data within 20%. The instability in two phase flow is quantified; it is found that microchannels of smaller hydraulic diameter ...

2009-09-15

7

Reborn quadrant anode image sensor  

International Nuclear Information System (INIS)

We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50?m and count rates up to one million events per second.

2009-06-01

8

Reborn quadrant anode image sensor  

British Library Electronic Table of Contents (United Kingdom)

We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial...

2009-01-01

9

Quadrant anode image sensor  

Science.gov (United States)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)

1976-11-01

10

Quadrant anode image sensor  

International Nuclear Information System (INIS)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.

9472-01-01

11

Methanol production FPSO plant concept using multiple microchannel unit operations  

British Library Electronic Table of Contents (United Kingdom)

Remote, offshore gas reserves have long been a challenging deepwater petroleum resource to tap. Natural gas in many offshore regions is plentiful, but lacks access to the market because of the logistical challenges and costs. Most large offshore gas discoveries are capped, and gas associated with oil production is re-injected into the reservoir or is flared. A more attractive option is to convert the gas into a liquid product on a floating production, storage, and offloading (FPSO) vessel. However, some conventional process technologies are not well suited for operation on floating vessels that are highly space and weight constrained and may challenge vessel stability during inclement weather. Microchannel process technology units under development offer intensified processes that are suit...

2008-01-01

12

Dialysis membrane for separation on microchips  

Energy Technology Data Exchange (ETDEWEB)

Laser-induced phase-separation polymerization of a porous acrylate polymer is used for in-situ fabrication of dialysis membranes inside glass microchannels. A shaped 355 nm laser beam is used to produce a porous polymer membrane with a thickness of about 15 .mu.m, which bonds to the glass microchannel and forms a semi-permeable membrane. Differential permeation through a membrane formed with pentaerythritol triacrylate was observed and quantified by comparing the response of the membrane to fluorescein and fluorescently tagging 200 nm latex microspheres. Differential permeation was observed and quantified by comparing the response to rhodamine 560 and lactalbumin protein in a membrane formed with SPE-methylene bisacrylamide. The porous membranes illustrate the capability for the present technique to integrate sample cleanup into chip-based analysis systems.

2010-07-13

13

High-power continuous wave 690 nm AlGaInP laser-diode arrays  

Energy Technology Data Exchange (ETDEWEB)

High-power diode laser arrays emitting at 690 nm have been developed for solid-state laser pumping. The laser diode bars (fill factor [approx]0.7) have been fabricated from single quantum well AlGaInP-based heterostructures. Using silicon microchannel heatsinks, a record high 360 W/cm[sup 2] per emitting aperture is achieved under continuous wave operation.

1995-03-06

14

High-power CW operation of AlGaInP laser-diode array at 640 nm  

Science.gov (United States)

Visible-emitting high-power laser bars are investigated at an emission wavelength of 640 nm. AlGaInP/GaInP, single tensile-strained quantum well, separate confinement heterostructures are fabricated into one cm long laser bars using a 0.7 fill factor. The low threshold current of the diode, combined with the aggressive heatsinking of a silicon microchannel cooler has resulted in more than 12 W of continuous wave output power.

1995-02-01

15

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

16

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

17

Surface modification with BSA blocking based on in situ synthesized gold nanoparticles in poly(dimethylsiloxane) microchip  

British Library Electronic Table of Contents (United Kingdom)

A stable BSA blocking poly(dimethylsiloxane) (PDMS) microchannel was prepared based on in situ synthesized PDMS-gold nanoparticles composite films. The modified microchip could successfully suppress protein adsorption. The assembly was followed by contact angle, charge-coupled device (CCD) imaging, electroosmotic flow (EOF) measurements and electrophoretic separation methods. Contact angle measurements revealed the coated surface was hydrophilic, water contact angle for coated chips was 45.2^o compared to a water contact angle for native PDMS chips of 88.5^o. The coated microchips exhibited reproducible and stable EOF behavior. With FITC-labeled myoglobin incubation in the coated channel, no fluorescence was observed with CCD image, and the protein exhibited good electrophoretic effect in ...

2010-01-01

18

Subcooled Flow Boiling in a Minichannel  

British Library Electronic Table of Contents (United Kingdom)

It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...

2011-01-01

19

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

20

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

 
 
 
 
21

Natural gas conversion to higher hydrocarbons using plasma interactions with surfaces. Final report  

Energy Technology Data Exchange (ETDEWEB)

Experiments are reported in which a methane plasma is created, and the methyl ions and hydrogen ions are accelerated within a microchannel array so that they interact with neutral methane molecules on the inside surfaces of the microchannels. No catalysts are used, and the device operates at room temperature. Impact energies of the ions are in the range of 10 eV to greater than 100 eV, and the energy delivered in the interaction at the surfaces causes the production of larger hydrocarbon molecules, such as C{sub 2}H{sub 2}, C{sub 2}H{sub 4}, and C{sub 2}H{sub 6}, along with C{sub 3}, C{sub 4}, C{sub 5}m C{sub 6}, C{sub 7}m and C{sub 8} molecules. There is a decreasing percentage of larger molecules produced, in comparison with the C{sub 2} and C{sub 3} types. Conversion effectiveness is greater at higher pressure, due to the increased ionic activity. The yield of the higher hydrocarbons depends upon the external voltage used, and voltage can be ...

1993-12-01

22

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have shown a clear dominance ...

2002-07-01

23

The Development of a Neutral Particle Detector for Observations of the Thermosphere  

Science.gov (United States)

One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight instrument uses electron impact ionization ...

2006-12-01

24

In-situ synthesis of poly(dimethylsiloxane)-gold nanoparticles composite films and its application in microfluidic systems.  

Science.gov (United States)

We presented a simple approach for in-situ synthesis of poly(dimethylsiloxane) (PDMS)-gold nanoparticles composite film based on the special characteristics of PDMS itself. It is an environmentally safe synthesis method without the requirement of additional reducing/stabilizing agents. The region where the resulting gold nanoparticles distribute (in the matrix or on the surface of the polymer) and the size of the nanoparticles, as well as the colour of the free-standing films, can be simply controlled by adjusting the ratio of curing agent and the PDMS monomer. The chemical and optical properties of these composite films were studied. Using such a method, gold nanoparticle micropatterns on PDMS surfaces can be performed. And based on the gold nanoparticles micropattern, further modification with antibodies, antigens, enzymes and other biomolecules can be achieved. To verify this ability, an immobilized glucose oxidase (GOx) reactor in microchannels was built and ...

2007-11-14

25

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing excitation/detection strategies which provide ...

1993-12-01