WorldWideScience
1

Computed tomography of head in Clinic Pediatrics  

Energy Technology Data Exchange (ETDEWEB)

138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.

1982-02-01

2

Trial of using computer tomography in the diagnosis of mediastinal diseases in children  

Energy Technology Data Exchange (ETDEWEB)

In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.

1981-01-01

4

Importance of computer tomography in paediatric diagnostics of abdominal and pelvic tumours  

Energy Technology Data Exchange (ETDEWEB)

In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.

1980-03-01

5

Computer tomographic ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.

1982-04-01

6

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.

1999-09-01

7

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

International Nuclear Information System (INIS)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere

1999-06-06

8

Using Multidetector Computed Tomography in a Swine Model to Assess the Effects of Sublingual Nitroglycerin and Intravenous Adenosine on Epicardial Coronary Arteries  

UK PubMed Central (United Kingdom)

This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed...Full Text Available

2009-12-01

9

Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults  

UK PubMed Central (United Kingdom)

Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available

2010-03-01

12

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

13

Computer tomographic diagnosis of intrathoracic lipoma  

Energy Technology Data Exchange (ETDEWEB)

A case of intrathoracic lipoma in a child is presented. The diagnosis was made before operation by means of computer-assisted tomography, a non-interventional procedure.

1984-04-14

14

Computed tomography in migratory disorders of human brain development  

International Nuclear Information System (INIS)

Computed tomographic findings in developmental brain anomalies are more easily classified when the system used is based on embryogenesis related to morphology. Analysis of computed tomographic findings in a series of 154 patients with brain anomalies (Chiari malformation not included) revealed that specific examples of abnormalities occurring in major stages of brain development may be recognized by computed tomography. This paper deals with a group of patients with abnormalities that reflect a disturbance in neuronal migration. (orig.).

16

Computed Tomography diagnosis of skeletal involvement in multiple myeloma  

International Nuclear Information System (INIS)

The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed ...

1994-06-01

17

Prediction of the compressive strength of vertebral bodies of the lumbar spine by quantitative computed tomography.  

Science.gov (United States)

The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488

1988-01-01

18

Diagnostic Value of C-reactive Protein in Complicated Appendicitis  

UK PubMed Central (United Kingdom)

PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available

2011-06-01

19

Significance of cranial computer tomography for the early diagnosis of peri- and postnatal damage  

Energy Technology Data Exchange (ETDEWEB)

It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.

1981-01-01

20

Incidental orbital calcifications on computed tomography scans; Calcificacoes orbitarias incidentais na tomografia computadorizada  

Energy Technology Data Exchange (ETDEWEB)

We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)

2001-02-01

21

Computer tomography of orbita in children  

Energy Technology Data Exchange (ETDEWEB)

The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.

1983-07-01

22

Computed tomography - old ideas and new technology  

International Nuclear Information System (INIS)

Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

2011-03-01

23

Evaluation of bone mineral content using Quantitative Computed Tomography  

International Nuclear Information System (INIS)

The authors have evaluated bone mineral content in the vertebral spongiosa by means of Computed Tomography. The method proposed by Genant and Cann [17, 18] has been applied to examine 164 healthy volunteers and 108 patients. Both healthy males and females showed a progressive bone mineral loss increasing with age; the bone mineral loss was most severe in females during the 4th and 5th decade of life. Pathology included patients with osteoporotic fractures (vertebral and femural neck), patients with partial gastrectomy, renal failure, primary hyperparathyroidism, Cushing syndrome, corticosteroid therapy. Bone mineral values were significantly lower in most pathologic groups. Computed Tomography proves thus to be a valuable method to assess bone mineral content and to identify patients at risk for fractures.

1988-01-01

24

Simulation approaches for nano-scale semiconductor devices  

CERN Document Server

Simulation approaches for nano-scale semiconductor devices

2004-01-01

25

Nano-Materials in Metal-Matrix Composites  

International Science & Technology Center (ISTC)

Metal Matrix Composites on the Basis of Nano-Materials

26

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

27

Differential diagnosis of tumorous lesions in the iliac bone in children  

Energy Technology Data Exchange (ETDEWEB)

The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.

1984-02-01

28

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

29

Quantification of lung surface area using computed tomography  

UK PubMed Central (United Kingdom)

ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available

2010-01-01

30

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

31

Limitations of Tc99m-MIBI-SPECT Imaging Scans in Persistent Primary Hyperparathyroidism  

UK PubMed Central (United Kingdom)

BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available

2011-01-01

32

Iofetamine I 123 single photon emission computed tomography is accurate in the diagnosis of Alzheimer's disease  

Energy Technology Data Exchange (ETDEWEB)

To determine the diagnostic accuracy of iofetamine hydrochloride I 123 (IMP) with single photon emission computed tomography in Alzheimer's disease, we studied 58 patients with AD and 15 age-matched healthy control subjects. We used a qualitative method to assess regional IMP uptake in the entire brain and to rate image data sets as normal or abnormal without knowledge of subjects'clinical classification. The sensitivity and specificity of IMP with single photon emission computed tomography in AD were 88% and 87%, respectively. In 15 patients with mild cognitive deficits (Blessed Dementia Scale score, less than or equal to 10), sensitivity was 80%. With the use of a semiquantitative measure of regional cortical IMP uptake, the parietal lobes were the most functionally impaired in AD and the most strongly associated with the patients' Blessed Dementia Scale scores. These ...

1990-04-01

33

Feature-based rectal contour propagation from planning CT to cone beam CT  

UK PubMed Central (United Kingdom)

The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available

2008-10-01

34

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

35

Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas  

UK PubMed Central (United Kingdom)

AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available

2011-09-07

36

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

37

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

38

An unusual presentation of metastatic adenocarcinoma of lung: a case report  

UK PubMed Central (United Kingdom)

We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available

39

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

40

Three-dimensional cranio-facial computed tomography  

International Nuclear Information System (INIS)

Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

1986-01-01

41

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

42

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

43

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

44

Imaging Automation and Volume Tomographic Visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-11-14

45

Computed tomography of hilar cholangiocarcinoma: a new sign  

International Nuclear Information System (INIS)

Thirty-seven patients with histologic proof of cholangiocarcinoma at the confluence were examined by computed tomography (CT) to determine whether this examination is of value in the assessment of these patients for surgery and whether there are any features specific to this type of tumor. Thirty-two patients showed intrahepatic duct dilatation; six of these showed dilatation of ducts in one lobe only. Eighteen patients had intrahepatic low-attenuation areas, while eight had a mass lesion in the porta hepatis. The results of this study show that CT provides useful anatomic information preoperatively but that the appearances are nonspecific. Lobar atrophy is highly suggestive of hilar cholangiocarcinoma, either of long-standing or with unilateral portal venous involvement.

1986-04-14

46

Computed tomography in the evaluation of soft tissue tumors  

International Nuclear Information System (INIS)

In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.

1986-01-01

47

Computed tomography in the evaluation of 41 cases of Ewing's sarcoma  

International Nuclear Information System (INIS)

Computed tomography (CT) has already proved extremely effective both in cerebral and abdominal pathology. Several recent publications describing first heterogeneous series [1, 2, 7, 11-17], then studies of a single type of lesion [3-6, 8] have illustrated its usefulness in the study of bone lesions. This report deals with 41 cases of Ewing's sarcoma studied by CT at the Institut Gustave Roussy from October 1977 to July 1981, and tries to show both the limitations and indications of this technique for the diagnosis, treatment, and follow-up of Ewing's sarcoma as well as in the diagnosis of any eventual recurrence. (orig.).

48

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

49

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

50

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.

1984-10-01

51

An application of the neutron television fluoroscopic system to neutron computed tomography  

International Nuclear Information System (INIS)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

52

High-Resolution Computed Tomography with Single-Slice Computed Tomography and 16-Channel Multidetector Computed Tomography: A Comparison Regarding Visibility and Motion Artifacts  

International Nuclear Information System (INIS)

Background: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. Purpose: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT ...

2007-11-01

53

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

56

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

57

Vascular injuries in intestinal obstruction. The role of computed tomography; Complicazioni vascolari nelle occlusioni intestinali: ruolo della tomografia computerizzata  

Energy Technology Data Exchange (ETDEWEB)

The paper investigates computerized tomography capabilities in showing vascular complications secondary to intestinal obstruction and for assessing the site and cause of obstruction. [Italian] Scopo del lavoro e' lo studio dell'uso della tomografia computerizzata nel riconoscimento di complicanze vascolari secondarie ad occlusione intestinale e della presenza, della natura e della sede dell'ostacolo alla canalizzazione intestinale.

1999-09-01

58

PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan  

International Nuclear Information System (INIS)

Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

2007-06-01

59

PET/CT cardiology: an area whose boundaries are still out of sight  

International Nuclear Information System (INIS)

Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.

2006-05-01

60

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications ...

1981-11-01

61

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications ...

62

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital ...

1981-01-01

63

Computer tomographic demonstration of so-called azygos continuation in the absence of the hepatic segment of the inferior vena cava  

International Nuclear Information System (INIS)

Dilatation of the azygos vein is usually due to increased pressure or flow, rarely is it diopathic. Another cause is so-called continuation of the azygos in cases of absence of the hepatic segment of the inferior vena cava. The method of choice for the investigation of azygos dilatation nowadays is computer tomotgraphy. Anomalies of the inferior vena cava can be recognised in this way unequivocally by a non-invasive method. Computer tomography frequently shows important additional abnormalities (e.g. situs inversus, polysplenia), since it demonstrates all organs situated in the plane of section. (orig.).

64

Sialography, echography and computed tomography in parotid gland study  

International Nuclear Information System (INIS)

The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.

1985-01-01

65

Role of Computed Tomography in postoperative diskitis  

International Nuclear Information System (INIS)

Six patients with diskitis following lumbar disk surgery were investigated by Computed Tomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic patients.

1988-01-01

66

Multidetector Computed Tomography in the Preoperative Workup of Hilar Cholangiocarcinoma  

International Nuclear Information System (INIS)

Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma.

2009-10-01

67

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

68

Importance of preoperative imaging with 64-row three-dimensional multidetector computed tomography for safer video-assisted thoracic surgery in lung cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...

2009-01-01

69

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

70

Imaging automation and volume tomographic visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-07-01

71

Computed tomography colonography: the future of colon cancer screening  

Energy Technology Data Exchange (ETDEWEB)

Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)

2008-10-15

72

Computed tomography colonography: the future of colon cancer screening  

International Nuclear Information System (INIS)

Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)

2008-10-01

73

Computed Tomography of the spine in multiple myeloma  

International Nuclear Information System (INIS)

Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.

1988-01-01

74

Cardiac transplantation. Value of computed tomography  

International Nuclear Information System (INIS)

In 9 over 12 patients who underwent cardiac transplantation computed tomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.

1986-01-01

75

Application of digital radiography to diagnosis of laryngeal diseases  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal ...

1986-01-01

76

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

77

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...

1988-01-01

78

Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons  

Energy Technology Data Exchange (ETDEWEB)

In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the ...

2007-07-01

79

Single photon emission computed tomography and its neurological application  

Energy Technology Data Exchange (ETDEWEB)

A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.

1984-12-01

80

Single photon emission computed tomography and its neurological application  

International Nuclear Information System (INIS)

A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.

81

Scintigraphic imaging of dementia: Technical acquisition  

International Nuclear Information System (INIS)

Scintigraphic imaging of dementia relies today essentially on the study of brain Single Photo Emission Computed Tomography (SPECT) perfusion, after intravenous injection of 99mTc radio-pharmaceutic. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear Medicine (http://eanm.org/). (author)

2007-06-01

82

Role of CT in TNM staging of laryngeal and hypopharyngeal tumors  

International Nuclear Information System (INIS)

70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.

1986-01-01

83

Right-sided invasive metastatic thymoma of the heart  

British Library Electronic Table of Contents (United Kingdom)

Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.

2011-01-01

84

Preparation and radiolabeling of IBZM: a potential D-2 specific brain imaging agents for SPECT  

International Nuclear Information System (INIS)

In developing new receptor-site specific brain imaging agents labeled with I-123 for single photon emission computed tomography (SPECT), an analog of raclopride, 3-["1"2"5I]-iodo-N-[(1-ethyl-2-pyrrolidinyl)-methyl]-2-hydroxy-6-me-thoxy benzamide (IBZM), was prepared using a method similar to that reported for raclopride and its derivatives. (author).

85

New concept to optimize emergency diagnoses in patients with multiple injuries  

International Nuclear Information System (INIS)

To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).

86

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

87

Kinetic estimation of infused Lipiodol within hepatoma using CT dynamic study  

Energy Technology Data Exchange (ETDEWEB)

Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).

1991-02-01

88

Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method  

Energy Technology Data Exchange (ETDEWEB)

Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.

1982-01-01

89

Computed tomography of the chest: A teaching file  

Energy Technology Data Exchange (ETDEWEB)

As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.

1987-01-01

90

Computed tomography of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).

91

Complete Dissection of a Hepatic Segment after Blunt Abdominal Injury Successfully Treated by Anatomical Hepatic Lobectomy: Report of a Case  

UK PubMed Central (United Kingdom)

A 21-year-old male patient was transferred to the emergency room of our hospital after suffering seat belt abdominal injury in a traffic accident. Abdominal computed tomography revealed a massive hematoma...Full Text Available

92

Clinical helical tomotherapy commissioning dosimetry  

International Nuclear Information System (INIS)

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.

2003-12-01

93

CT scan findings in cerebral paragonimiasis  

International Nuclear Information System (INIS)

Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).

1982-01-01

94

CT imaging of a primary malignant mixed mullerian tumor arising from the peritoneum  

British Library Electronic Table of Contents (United Kingdom)

Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computed tomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.

2008-01-01

95

Bilateral enlargement of the orbital muscles: first manifestation of renal adenocarcinoma; Espessamento da musculatura extrinseca orbitaria bilateralmente: manifestacao primaria de adenocarcinoma renal  

Energy Technology Data Exchange (ETDEWEB)

The authors present an unusual case of a patient with orbital metastases from renal carcinoma involving the extra ocular muscles bilaterally. The importance of computed tomography for the differential diagnosis with other orbital lesions is emphasized. (author)

2000-06-01

96

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

97

New mass screening project for lung cancer with mobile spiral computed tomography (CT) and computed radiography (CR) in Ehime district  

Energy Technology Data Exchange (ETDEWEB)

To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)

2002-01-01

98

Nano photonic sensors for microdamage detection : an exploratory simulation.  

Energy Technology Data Exchange (ETDEWEB)

Nano photonic materials are synthetically manufactured crystals at the nano scale with the target of creating a microstructure with a special electro-magnetic periodicity. Such nano photonic materials have the ability to control light propagation and thus are capable of creating photonic bandgaps in the frequency domain. We propose using nano photonic crystals as sensors to detect microdamage in composite materials. We demonstrate using a simulation model that a nano photonic sensor attached to a composite bar experiences a significant change in its bandgap profile when damage is induced in the composite bar. The model predicts the frequency response of the nano photonic sensor using the transfer matrix method. A damage metric to evaluate the change in the frequency response is developed. Successful developments of nano photonic sensors ...

2005-04-01

99

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

100

New thermal neutron imaging facility at the University of Texas reactor  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.

1999-09-01

101

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

102

Development of Methods for Obtaining Position Image and Chemical Binding Information from Flow Experiments of Porous Media  

Energy Technology Data Exchange (ETDEWEB)

Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.

1998-12-01

103

Biomechanical properties of the femoral neck relative to osteosynthesis methods and bone mineral content assessed by computed tomography  

International Nuclear Information System (INIS)

Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs.

104

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

105

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...

2008-06-01

106

Computed Tomography of the complications of prosthetic surgery of the abdominal aorta  

International Nuclear Information System (INIS)

Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 ...

1997-01-01

107

Fundamental concepts of digital image processing  

Science.gov (United States)

The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might ...

1983-03-01

108

Computational mouse atlases and their application to automatic assessment of craniofacial dysmorphology caused by the Crouzon mutation Fgfr2C342Y  

British Library Electronic Table of Contents (United Kingdom)

Abstract Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landma...

2007-01-01

109

Creation of nitrogen-vacancy centres in diamond with high resolution  

International Nuclear Information System (INIS)

Nowadays, diamond and the nitrogen-vacancy (NV) colour centres constitute the best solid-state system in view of quantum-computing applications. It has also been shown recently that single NV centres could be used as nanoscale magnetic sensors. Such applications require the creation of single NV centres with very high resolution and with a high efficiency. The nano-implanter at the university of Bochum provides low energy nitrogen ions which can be implanted through a hole pierced in the tip of an atomic force microscope. Ultrapure diamond samples have been implanted with spot sizes of 50nm and less. Stimulated Emission Depletion (STED) microscopy has been used to characterise and resolve the implanted spots.

2010-03-21

113

Processing and Electrochemical Property Characterization of Nano porous Electrodes for Sustainable Energy Applications  

International Nuclear Information System (INIS)

Preparation and electrocatalytic reactions of nano porous materials in biodegradable fluids were studied. Electrochemical etching was conducted to selectively extract metallic elements from alloys to form porous structures. Electrocatalytic properties of the porous electrodes were characterized. Comparative studies on the electrochemical activities of the nano porous metallic electrodes with bulk metallic wire catalysts were performed. It is found that the current density at the nano porous electrode is three times higher than that of the bulk electrode

2009-01-01

115

Multi-functional Biocompatible Coatings  

International Science & Technology Center (ISTC)

Multi-functional Bioactive Nano-structured Coatings for Load-Bearing Implants

119

Sinonasal malignant tumors involvement of the orbit and skull: a computed tomography study  

International Nuclear Information System (INIS)

Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through ...

2002-01-01

120

High resolution computed tomography in the study of cervical spine trauma  

International Nuclear Information System (INIS)

Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently ...

1989-01-01

121

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous ...

122

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to ...

1984-09-01

123

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to ...

1984-01-01

124

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any diagnostic certainty were selected for follow-up, and ...

2006-11-15

125

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

126

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

127

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder ...

2009-04-15

128

Computer assisted axial tomography (Emi scan) in neurologic investigation  

Science.gov (United States)

Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of ...

1974-01-01

129

Computed tomography of the mediastinal tumor  

Energy Technology Data Exchange (ETDEWEB)

Forty-one cases of mediastinal tumor examined by computed tomography were reviewed. CT findings of the mediastinal malignancy were as follows: 1) inhomogeneous density on contrast CT, 2) equivocaton of fat plane surrounding the tumor, 3) irregular margin. Benign teratoma had smooth margin and included fat or calcification density. Mediastinal seminoma was observed as a lobulated mass with no calcification on CT. These findings were similar to the patterns of malignant thymoma or lymphoma. Consequently, it was very difficult to differentiate between malignant thymoma and malignant lymphoma by CT. According to our data, malignant thymoma tended to expand to only one side of the anterior mediastinum and to invade the anterior chest wall. On the other hand, malignant lymphoma of anterior medistinal type expanded into the trachea and the superior vena cava. In patients with sarcoidosis, the enlargement of bilateral hilar lymph nodes was commonly ...

1984-12-01

130

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.

1990-01-01

131

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

132

Value of computed Tomography in re-staging patients undergoing second-look laparotomy for ovarian cancer  

International Nuclear Information System (INIS)

Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.

1991-01-01

133

Successful coil embolization of an unusual aorto-superior mesenteric vein fistula.  

Science.gov (United States)

The aortovenous fistulas are rare, most of them are aortocaval fistula. The non-caval communication of the fistula is sparse. Herein we report a 47-year-old female diagnosed as traumatic aorto-superior mesenteric vein (Ao-SMV) fistula. The abdominal pain, fullness, and frank bruit on abdominal auscultation suggested the diagnosis of an intra-abdominal arteriovenous fistula. The diagnosis of Ao-SMV was further confirmed by the computed tomography (CT) and aortography. The fistula was successfully treated with transcatheter coil embolization. This is the first case of Ao-SMV fistula. It provides an alternative option of treatment other than conventional surgery. PMID:19327940

2009-03-26

134

Spectrum of abdominal pathologies detected with CT in long term dialysis patients  

Energy Technology Data Exchange (ETDEWEB)

As a consequence of the expanded use of long term hemodialysis and continuous ambulatory peritoneal dialysis (CAPD) treatments and extended life spans, complications of end-stage renal disease and dialysis treatments are being encountered with increasing frequency in these patients. Computed tomography can accurately depict many of the potential complications of end-stage renal disease on dialysis. This article presents the abdominal CT findings of 429 end-stage renal disease patients who are on either hemodialysis or continuous ambulatory peritoneal dialysis treatment.

2009-11-15

135

Sonography and Computed Tomography in the evaluation of giant Baker's cysts  

International Nuclear Information System (INIS)

The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.

1991-01-01

136

Roentgenological analysis of sternocostoclavicular hyperostosis by computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Roentgenological analysis of the anterior chest wall was performed in twenty six patients with sternocostoclavicular hyperostosis. Initial hyperostotic change was seen at the first costosternal junction with ventral protrusion. Hyperostosis gradually developed around the first ribs, and irregular hyperostotic changes were also seen along the costoclavicular ligaments. Even in the final stage, however, sternoclavicular joint spaces were well preserved. These findings suggest that sternocostoclavicular hyperostosis is a disorder initiated around the costal cartilage including the periosteum and perichondrium, and that arthritis is not a condition stemming from that disorder.

1989-01-01

137

Involvement of the chest and abdominal wall as a rare manifestation in Hodgkin's disease  

Energy Technology Data Exchange (ETDEWEB)

Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.

1983-03-01

138

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

139

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

140

Computed Tomography of the cranio-cervical junction in rhematoid arthritis  

International Nuclear Information System (INIS)

Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.

1987-01-01

141

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

142

Usefulness of Computed Tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality  

International Nuclear Information System (INIS)

Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using ...

2005-11-01

143

Tracheal compression by mediastinal masses in children: CT evaluation  

Energy Technology Data Exchange (ETDEWEB)

Chest computed tomography (CT) was valuable in detecting extrinsic tracheal compression by mediastinal masses in two pediatric patients. This prompted an independent evaluation by CT of 14 children with masses involving the middle mediastinum and possible intrathoracic tracheal narrowing. Computer programs permit precise calculation of tracheal cross-sectional areas. Any apparent decrease in tracheal area may be compared with CT-derived data in normal children. Chest CT not only demonstrates the presence of extrinsic airway compression in pediatric patients with mediastinal masses, but also is capable of precisely measuring the extent of this narrowing. This method identifies children at potential risk for respiratory compromise and may aid in subsequent therapy.

1983-10-01

144

Image diagnosis of parathyroid glands in chronic renal failure  

Energy Technology Data Exchange (ETDEWEB)

Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.

1983-07-01

145

Computed tomography of the acetabular fractures  

Energy Technology Data Exchange (ETDEWEB)

In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.

1986-04-15

146

Clinical evaluation of Fuji computed radiography (FCR) by physicians including non-radiologist  

Energy Technology Data Exchange (ETDEWEB)

In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).

1990-04-01

147

Clinical evaluation of Fuji computed radiography (FCR) by physicians including non-radiologist  

International Nuclear Information System (INIS)

In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).

1988-07-01

149

Formation of pentagonal Cu nano wires  

Energy Technology Data Exchange (ETDEWEB)

The development of nano/molecular devices will require atomic-sized electrical contacts or nano metric conductors for wiring. As metal nano wires exhibit quantized conductance at room temperature, quantum transport effects will play an important role in the practical implementation of nano devices. As copper is currently used as interconnecting metal in standard microelectronics, the characterization of Cu nano wire properties deserves special attention. In this work, we show a detailed study of structural and electronic properties of atomic-sized Cu wires. In particular, we have established a complete correlation between the conductance and the structure by associating real-time atomic resolution transmission electron microscopy imaging with molecular dynamic simulations, conductance measurements and conductance calculations. Our study has revealed the structural relaxation of Cu ...

2004-07-01

150

Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography  

Energy Technology Data Exchange (ETDEWEB)

A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver ...

1990-05-01

151

Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography  

International Nuclear Information System (INIS)

A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver ...

1990-01-01

152

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the ...

1986-01-01

153

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...

1986-01-01

154

Preparation and biological properties of a novel composite scaffold of nano-hydroxyapatite/chitosan/carboxymethyl cellulose for bone tissue engineering  

UK PubMed Central (United Kingdom)

In this study, we report the physico-chemical and biological properties of a novel biodegradable composite scaffold made of nano-hydroxyapatite and natural derived polymers of chitosan and carboxymethyl...Full Text Available

155

Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions  

International Nuclear Information System (INIS)

Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV ...

1988-01-01

156

The role of computed tomography in complex facial trauma  

Energy Technology Data Exchange (ETDEWEB)

Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury resulting blindness. CT was superior to ...

1988-02-15

157

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

158

Reflection tomography using finite element method ray tracing  

Energy Technology Data Exchange (ETDEWEB)

The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. Since the FEM (Finite Element Method) ray tracing we have developed goes well the inverse velocities structure, we can apply the inversion problem to complex geological model. This report consists of 3 articles. 1) ...

1996-12-01

159

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-11

160

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-01

161

Improvement of FCR-linear tomography using digital image processing  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image ...

1994-02-01

162

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI ...

2000-05-01

163

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so ...

164

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of either the anatomical or functional imaging ...

2001-10-01

165

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an ...

2009-03-15

166

New laser nano-technologies for cleaning the semiconductor materials  

International Nuclear Information System (INIS)

2009 p. 143-144 Ukraine Lepikh, Ya.I. Odesa National University, Odesa

2009-09-15

167

Nano-chemistry is the new course in the system of chemistry sciences  

International Nuclear Information System (INIS)

... 30-31 Oct 2009 Tajik National University(Tajikistan) 146 p. INORGANIC,

2009-10-01

168

Graphitic nano tubes and aligned nano tubes films  

Energy Technology Data Exchange (ETDEWEB)

Carbon nano tubes are easily produced in macroscopic quantities, however their characterisation and possible applications are still rather limited. We have developed a new method to make aligned nano tube films which open new opportunities, not only for basic research but also for eventual applications. With this method the tubes can be aligned either parallel or perpendicular to the surface. We give a short review of the microscopic properties of single tubes and the bulk properties of the aligned films. (author). 24 refs., 6 figs.

1996-03-01

169

A hierarchical lattice structure and formation mechanism of ZnO nano-tetrapods  

International Nuclear Information System (INIS)

The existence of characteristic longitudinal optical and transverse optical phonons of cubic ZnO in ZnO nano-tetrapods is determined by Raman spectroscopy and first-principles calculations. Stacking sequence change at the boundary of the core and legs is also identified by high-resolution transmission electron microscopy. Based on this experimental and theoretical evidence, we demonstrate that the lattice structure of ZnO nano-tetrapods is hierarchical with a zinc blende core connecting to four wurtzite legs. Furthermore, we establish the atomic configuration and propose a formation mechanism induced by Laplace pressure in the initial growth stage of ZnO nano-tetrapods.

2009-08-12

170

Role of positron emission tomography-computed tomography in staging and early chemotherapy response evaluation in children with neuroblastoma  

International Nuclear Information System (INIS)

To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. ...

171

Study of both nature and topology of the nano-porous materials by the positron annihilation spectroscopy  

International Nuclear Information System (INIS)

By the methods of the angular distribution of photon annihilation, time distribution of photon annihilation, photoluminescence spectroscopy, Fourier IR-spectroscopy, atomic force microscopy the detail information on relation of the structural and physical properties of the porous nano-structures is obtained. Study of pores sizes in a different nano-porous materials, such as the porous silicon, porous anode aluminium oxide, porous solids exposed to light atoms ion implantation (hydrogen, deuterium, helium) is carried out.

2003-09-15

172

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A ...

173

Separation of Minor Actinides and Lanthanides with Carbon Nano-materials  

Energy Technology Data Exchange (ETDEWEB)

Recently we have found that carbon nano-materials have ability to recognize softer actinides(III). In this presentation, separation of americium(III) from lanthanides(III) by chromatography with carbon nano-materials, such as carbon nano-tubes and graphite, has been investigated by batch adsorption experiments and chromatography. The separation factor (SF) between americium(III) and lanthanide(III) was about 2 in the range of pH from 1 to 4 by using carbon nano-tube, graphite and activated charcoal. The separation factor depended on the diameter of carbon nano-tubes. Smaller one, 3-20 nm diameter, showed the best selectivity for americium(III), which separation factor was about 2.0, although larger one, 40-70 nm, showed almost no selectivity. The same behavior has been observed by using graphite powder and activated charcoal although acid- or alkali pretreated activated charcoal ...

2009-06-15

174

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

175

The role of Multidetector CT in the evaluation of the left atrium and pulmonary veins anatomy before and after radio-frequency catheter ablation for atrial fibrillation. Preliminary results and work in progress.Technical note  

International Nuclear Information System (INIS)

Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward.

176

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

177

Subclinical interstitial lung involvement in rheumatic diseases. Correlations of high-resolution Computed Tomography patterns with functional and cytologic findings  

International Nuclear Information System (INIS)

The aims of this study were to quantify the severity and extent of subclinical interstitial lung disease as depicted on HRCT and to study the relationship between the patterns of lung disease quantified by HRCT and the functional parameters and bronchoalveolar lavage findings in patients with rheumatic diseases. The results confirm that HRCT is a sensitive tool in detecting interstitial lung disease in patients with rheumatic diseases with no signs and symptoms of pulmonary involvement. The relationship between the different HRCT patterns and bronchoalveolar lavage cell profiles can identify patients at higher risk of developing irreversible lung fibrosis. A long-term, prospective follow-up study is needed to determine whether these patients will develop over pulmonary disease.

1999-01-01

178

Sonography, Computed Tomography and ERCP in the diagnosis of focal exocrine pancreatic disease  

International Nuclear Information System (INIS)

In spite of the improved imaging techniques currently available, mortality for pancreatic cancer is still high, and pancreatics is often diagnosed only in its advanced stages. The authors investigated the value of different imaging techniques - i.e., US, CT, and ERCP - for an early diagnosis, when a more effective (curative?) treatment can be suggested. Fifty-six cases of pancreatic cancer and 36 cases of chronic pancreatitis were evaluated. The results indicate that ERCP, with the help of statistical methods, is superior to US and CT not only in evaluating early neoplastic or inflammatory lesions, but also for their differential diagnosis. In the letter case, ERCP can sometimes be used as a valid alternative to fine-needle aspiration biopsy.

1991-01-01

179

Real-time imaging for neutron radiography at KURRI  

International Nuclear Information System (INIS)

For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).

1987-07-01

180

Radioiodinated phenoxyacetic acid derivatives as potential brain imaging agents, 2; Structure-biodistribution relationship  

Energy Technology Data Exchange (ETDEWEB)

In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The alpha,alpha-dimethylester derivative, amide derivatives and diamine derivatives, which were stable to hydrolysis, showed low blood activity levels following intravenous administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with SPECT devices.

1989-09-01

181

Radioiodinated 1-substituted-4-phenylpiperazines as potential brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

A series of four 125I-labeled 1-substituted-4-phenylpiperazines were prepared and evaluated in rats as potential brain imaging agents. The compounds were labeled using (125I)iodide/chloramine-T or iodine monochloride and isolated in 48-60% radiochemical yields. The tissue distribution studies indicated that a butyrophenone derivative demonstrated the best overall brain-imaging properties. Compared with the compounds having other 1-substituents this agent had a more prolonged retention of activity in the brain and higher brain-to-blood ratios over the 4-h period studied. The in vivo behavior of this agent is comparable to that of radioiodinated N-isopropyl-p-iodoamphetamine, and, because it can be labeled directly via electrophilic methods, it has substantial potential for use in brain imaging with single photon emission computed tomography.

1985-01-01

182

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

183

Noninvasive prediction of vertebral body compressive strength using nonlinear finite element method and an image based technique  

British Library Electronic Table of Contents (United Kingdom)

Noninvasive prediction of vertebral body strength under compressive loading condition is a valuable tool for the assessment of clinical fractures. This paper presents an effective specimen-specific approach for noninvasive prediction of human vertebral strength using a nonlinear finite element (FE) model and an image based parameter based on the quantitative computed tomography (QCT). Nine thoracolumbar vertebrae excised from three cadavers with an average age of 42 years old were used as the samples. The samples were scanned using the QCT. Then, a segmentation technique was performed on each QCT sectional image. The segmented images were then converted into three-dimensional FE models for linear and nonlinear analyses. A new material model was implemented in our nonlinear model being more...

2010-01-01

184

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization system.

1981-10-01

185

Long-term survival following radical surgery after chemotherapy for esophagogastric adenocarcinoma with extensive lymph node metastases: Report of a case  

British Library Electronic Table of Contents (United Kingdom)

A 46-year-old man was referred to us after he presented to his local physician complaining of difficulty eating. Upper gastrointestinal endoscopy revealed a tumor at the esophagogastric junction (EGJ), and moderately differentiated adenocarcinoma was diagnosed from the biopsy findings. Computed tomography (CT) showed apparent enlargement of the pretracheal lymph nodes, the lymph nodes around the bilateral recurrent laryngeal nerves, and the lower thoracic paraesophageal lymph nodes, confirming metastasis. Since the disease was far advanced esophagogastric cancer with marked lymph node metastases throughout the mediastinum, curative resection would have been unlikely. Thus, he was commenced on systemic chemotherapy with cisplatin (90 mg/body, day 8) + S-1 (120 mg/body/day, given for 3 weeks...

2011-01-01

186

Laparoscopic Transduodenal Ampullectomy for Benign Ampullary Tumors  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction: Transduodenal ampullectomy (TDA) can be performed for benign and premalignant tumors of the ampulla of Vater (AOV) as an alternative to pancreaticoduodenectomy. However, the laparoscopic approach has rarely been attempted. In this report 2 cases of benign ampullary tumor that were treated by totally laparoscopic TDA. Patients and Methods: Case 1 was of a 75-year-old female who was admitted with left knee pain and underwent arthroscopic debridement. On postoperative day 6, she showed elevated levels of alkaline phosphatase, aspirate aminotransferase, alanine transaminase, and gamma-glutamyl transpeptidase, without any other laboratory test abnormality. She had no complaint of abdominal pain, and physical examinations were unremarkable. Computed tomography (CT), magnet...

2010-01-01

187

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper summarize the practice of the standards passed over the past one year, which ...

2009-03-01

188

Feeding of the megamouth shark (Pisces: Lamniformes: Megachasmidae) predicted by its hyoid arch: A biomechanical approach  

British Library Electronic Table of Contents (United Kingdom)

Abstract Studies of the megamouth shark, one of three planktivorous sharks, can provide information about their evolutionary history. Megamouth shark feeding has never been observed in life animals, but two alternative hypotheses on biomechanics suggest either feeding, i.e., ram feeding or suction feeding. In this study, the second moment of area of the ceratohyal cartilages, which is an indicator of the flexural stiffness of the cartilages, is calculated for 21 species of ram- and suction-feeding sharks using computed tomography. The results indicate that suction-feeding sharks have ceratohyal cartilages with a larger second moment of area than ram-feeding sharks. The result also indicates that the ram-suction index, which is an indicator of relative contribution of ram and suction behavi...

2011-01-01

189

Fast Beam Intensity Measurements for the LHC  

CERN Document Server

Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, microwave technology, cryogenics, vacuum ...

2010-01-01

190

Extrinsic allergic alveolitis induced by the yeast Debaryomyces hansenii.  

Science.gov (United States)

A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192

2002-11-01

191

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

192

Computed tomography of middle ear cholesteatomas without tympanic membrane perforation  

International Nuclear Information System (INIS)

The growth of a middle ear cholesteatoma behind a normal tympanic membrane is a rate though possible event. In such cases, CT may provide useful information for diagnosis. The results are presented of a CT study carried out on 14 patients affected with unilateral conductive hearing loss and with normal tympanic membrane. CT allowed the diagnosis of meddle ear cholesteatoma to be made in all cases. All patients were treated with surgery: 8 of them underwent tympanoplasty and 6 explorative tympanotomy. While the diagnosis of cholesteatoma was confirmed in 13 patients, in 1 case tympanosclerosis was diagnosed. CT diagnosis of middle ear cholesteatoma is based on the demonstration of a low-density soft-tissue mass, in association with bone erosion or ossicular dislocation. The author emphasizes the difficulty of a CT diagnosis of cholesteatoma in the patients with middle ear soft-tissue masses in the absence of bone alterations.

1991-01-01

193

Challenges in presenting high dimensional data to aid in triage in the DARPA virtual soldier project.  

Science.gov (United States)

One of the goals of the DARPA Virtual Soldier Project is to aid the field medic in the triage of a casualty. In Phase I, we are currently collecting 12 baseline experimental physiological variables and a cardiac gated Computed Tomography (CT) imagery for use in an prototyping a futuristic electronic medical record, the "Holomer". We are using physiological models and Kalman filtering to aid in diagnosis and predict outcomes in relation to cardiac injury. The physiological modeling introduces another few hundred variables. Reducing the complexity of the above into easy-to-read text to aid in the triage by the field medic is the challenge with multiple display solutions. A description of the possible techniques follows. PMID:15718701

2005-01-01

194

Brain tumor in childhood. Hjernesvulst hos barn  

Energy Technology Data Exchange (ETDEWEB)

Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.

1990-05-01

195

The clinical application of positron emission tomography to colorectal cancer management  

International Nuclear Information System (INIS)

Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computed tomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose (FDG)-PET for screening asymptomatic individuals and current modalities ...

2001-09-01

196

Reflection tomography using finite element method ray tracing  

Energy Technology Data Exchange (ETDEWEB)

The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. After subdividing subsurface into triangular element we shoot off the ray into subsurface by the Snell`s law. And then after taking the ray path which is similar to proper assumption we can calculate travel time. With ...

1996-12-01

197

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

198

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

199

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

200

Single photon emission tomography of the pituitary: preliminary communication.  

UK PubMed Central (United Kingdom)

A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available

1981-09-01

201

Optical Coherence Tomography Findings in Idiopathic Macular Holes  

UK PubMed Central (United Kingdom)

Purpose. To describe the characteristics of idiopathic macular holes (MH) on optical coherence tomography (OCT) and correlate OCT with clinical assessment. Design....Full Text Available

2011-01-01

202

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea was derived from our ...

1986-01-01

203

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for automatic measurement of ...

2010-10-01

204

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...

2003-03-01

205

Sinonasal malignant tumors involvement of the orbit and skull: a computed tomography study; Comprometimento orbito-craniano por tumores malignos sinonasais: estudo por tomografia computadorizada  

Energy Technology Data Exchange (ETDEWEB)

Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through ...

2002-10-01

206

Reevaluation of the 'Falx sign'  

Energy Technology Data Exchange (ETDEWEB)

Visualization of falx cerebral on non-enhanced computer tomography (CT) of children with severe head injuries (the falx sign) has been regarded as an evidence of subarachnoid hemorrhage. On the contrary, other authors have reported reverse results. To evaluate clinical significance of the falx sign, authors studied frequency of visualization and CT number of falx cerebri and dural sinuses in 65 children with head injury and 65 children without head injury examined by cranial computer tomography at the Department of radiology, St Paul's Hospital, Catholic Medical College from March to September, 1981. All patients with head trauma were studied within 1 week of the traumatic event. Visualization of falx cerebri was observed at slice in the region of lateral ventricle and slice near to vertex respectively. On the slice in the region of lateral ventricle, falx cerebri was identified in 82% of all ...

1982-06-15

207

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being ...

2001-07-01

208

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger ...

1992-01-01

209

Proceedings of clinical SPECT [single photon emission computed tomography] symposium  

International Nuclear Information System (INIS)

It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which ...

1986-09-22

210

Failed nuclear fuel rod analysis by gamma computed tomography  

International Nuclear Information System (INIS)

Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computed tomography technique is used to obtain such distributions in the area of ...

211

Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography  

International Nuclear Information System (INIS)

Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% ...

2010-08-01

212

Daily cone-beam computed tomography used to determine tumour shrinkage and localisation in lung cancer patients  

Energy Technology Data Exchange (ETDEWEB)

Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant ...

2010-10-15

213

Correct diagnosis of vascular encasement and longitudinal extension of hilar cholangiocarcinoma by four-channel multidetector-row computed tomography  

International Nuclear Information System (INIS)

Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to ...

2009-01-01

214

Computed tomography in the diagnosis of cavum septum pellucidum  

Energy Technology Data Exchange (ETDEWEB)

The cavum septum pellucidum is an anatomical variants of the septum pellucidum, and lying between two lateral ventricles and this is referred to as the fifth ventricle. Occasionally, posterior extension of the cavum septum pellucidum towards the splenium is seen and this is known as the cavum vergae, or sixth ventricle. The septum is double membrane and occasionally a narrow cavity containing CSF is present between these membrane. The roof of the cavum septum pellucidum is formed by the corpus callosum and its floor by the anterior pillars of the fornix. This cavum outlined with air is occasionally seen in the pneumoencephalography. Brain CT scans of 1000 patients were performed, and the diagnosis could be made on the basis of the characteristic shape, density and location. Other diagnostic procedure are not necessary in these cases. Patients were examined with CT scanner from June-80' to Dec-80', at department of radiology, Maryknoll Hospital, and 13 cases were ...

1981-09-15

215

Computed tomography in AIDS-related thoracic diseases; Computertomographie AIDS-assoziierter Thoraxerkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Pulmonary infections and tumors are a major cause of death in patients with AIDS. The combination of clinical, radiological, laboratory, and pathohistological data helps to narrow the spectrum of differential diagnoses or even allows a specific diagnosis in many patients. Nevertheless, an accurate diagnosis should be obtained as soon as possible during the clinical course of the illness to initiate treatment in time. Computed tomography (CT) has proven to provide promising results in the diagnosis of AIDS-related throacic diseases. The aim of this paper was to demonstrate the diagnostic capacities of CT in the context of particular AIDS-related thoracic pathologies. Additional information on the spectrum of pathological agents and on differential diagnostic signs is summarized. (orig.) [Deutsch] Pulmonale Infektionen und Tumore sind eine wesentliche Todesursache bei Patienten, die am erworbenen Immunmangelsyndrom AIDS leiden. In den meisten ...

1996-07-01

216

Computed Tomography in the study of pulmonary tuberculosis  

International Nuclear Information System (INIS)

The authors carried out a retrospective study on 4 years' work on a series of patients with proved active tuberculosis examined in the Departments of Bronchopneumology and Infectious Disease of the Arezzo Civil Hospital. The population was heterogenerous from the immunologic viewpoint. This paper compared the effectiveness of Computed Tomography (CT) with that of conventional chest radiography (CR) in the diagnosis and prognosis of tuberculosis. All patients underwent chest CR in double projection and conventional CT studies of the chest; 16 patients were also submitted to high resolution CT (HRCT). Consolidation was the most frequent parenchymal lesion in immunocompetent patients; it was often associated with cavitation, with no clear topographic prevalence in the upper lobes. Pleural effusion, as the only sign of disease and with empyema features, was found in 10 immunocompetent patients. No predominant pattern was found in the other two ...

1997-01-01

217

Comparison of sclerosing cholangitis with autoimmune pancreatitis and infiltrative extrahepatic cholangiocarcinoma. Multidetector-row computed tomography findings  

International Nuclear Information System (INIS)

The aim of this study was to compare multidetector-row computed tomography (MDCT) findings between cases of sclerosing cholangitis with autoimmune pancreatitis (SC-AIP) and infiltrative extrahepatic cholangiocarcinoma (IEC). We retrospectively assessed MDCT findings from 16 IEC cases and 13 SC-AIP cases. MDCT findings were analyzed with regard to location, length, wall thickness, contour, stricture wall enhancement pattern, proximal duct diameter, and the presence of diffuse concentric thickening in the proximal duct and gallbladder wall thickness. Stricture length, stricture wall thickness, and proximal duct diameter were significantly smaller for SC-AIP than for IEC: 19.3#+-#8.7 vs. 31.8#+-#12.0 mm (P=0.004), 2.1#+-#1.3 vs. 4.1#+-#1.3 mm (P<0.001), and 9.2#+-#3.9 vs. 13.3#+-#5.0 mm (P=0.012), respectively. SC-AIP was correlated with stricture location in both the intrapancreatic and hilar hepatic bile ducts, concentric stricture contour ...

2010-04-01

218

Accuracy of single versus combined use of ultrasonography or computed tomography in the localization of parathyroid adenoma  

International Nuclear Information System (INIS)

Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried ...

219

Nanoporous materials can be made stiffer than non-porous counterparts by surface modification  

Energy Technology Data Exchange (ETDEWEB)

Nano-materials in which a large fraction of atoms resides within a few atomic layers near the surface can be designed to have novel properties by manipulating their surface parameters. We show that the effective elastic constants of nano-porous/cellular materials can be made to exceed those of the parent materials provided the pore surface elastic parameters satisfy certain conditions. These stiff nano-porous materials herald a radical breakthrough in sandwich-type construction.

2006-06-15

220

Nanoporous materials can be made stiffer than non-porous counterparts by surface modification  

International Nuclear Information System (INIS)

Nano-materials in which a large fraction of atoms resides within a few atomic layers near the surface can be designed to have novel properties by manipulating their surface parameters. We show that the effective elastic constants of nano-porous/cellular materials can be made to exceed those of the parent materials provided the pore surface elastic parameters satisfy certain conditions. These stiff nano-porous materials herald a radical breakthrough in sandwich-type construction.

2006-06-01

221

Direct observations of dislocation substructures formed by nano-indentation of the #alpha#-phase in an #alpha#/#beta# titanium alloy  

International Nuclear Information System (INIS)

Nano-indentation has been used to assess the hardness of equiaxed grains of #alpha#-Ti as a function of orientation. Surface normals of these grains in metallographic sections were assessed using orientation imaging microscopy. Thin membranes of material from below a series of nano-indentations were excised by use of a dual-beam focused ion beam instrument. In this way, the dislocation substructures beneath individual indentations were characterized using transmission electron microscopy, permitting an identification of both statistically stored and geometrically necessary dislocations.

2005-07-25

222

Computer Security and the Web  

CERN Multimedia

Computer Security and the Web

1997-01-01

223

Three-terminal electric transport measurements on gold nano-particles combined with ex situ TEM inspection  

International Nuclear Information System (INIS)

We have fabricated nanometer-spaced electrodes on electron-transparent silicon nitride membranes. A thin Cr/Au layer is evaporated on the backside of the membrane which serves as a gate electrode. Using these devices, we have performed three-terminal electron transport measurements on gold nano-particles at liquid helium temperature. Coulomb Blockade features have been observed and the capacitance to the gate has been extracted. After transport measurements, the Cr/Au back gate is removed and the devices are inspected with a transmission-electron microscope (TEM). TEM inspection reveals the presence of a few nano-particles in the nanogap, which is in agreement with the transport measurements. In addition, the nano-particle size as observed by TEM coincides with the one estimated from the gate capacitance value.

2009-10-14

224

Preparation and characterization of nano hydroxyapatite/polymeric composites materials. Part I  

British Library Electronic Table of Contents (United Kingdom)

The present study is focused on preparation of nano composite materials and the effect of citric acid on their different properties. The formation of nano HA and its interaction with chitosan (C), gelatin (G) polymers and citric acid (CA) materials were studied. The Fourier Transformed Infrared Spectroscopy (FT-IR), X-ray diffraction (XRD), thermo-gravimetric analysis (TGA), transmission electron microscope (TEM), and scanning electron microscope (SEM) were used to characterize these composite materials. The compressive strength (CS) was also measured to know the reinforcement of the prepared composites. The results show that carboxylic and amino groups play crucial role for HA formation on chitosan-gelatin polymeric matrix in the presence of citric acid (CA). The formation of nano HA part...

2011-01-01

225

LiNO3 molten salt assisted synthesis of spherical nano-sized YSZ powders in a reverse microemulsion system  

British Library Electronic Table of Contents (United Kingdom)

Spherical nano-sized YSZ (yttria stabilized ZrO2) powders were successfully synthesized via a reverse microemulsion system. The water droplets in the microemulsion system of yclohexane/water/span85/Triton X-100/hexyl alcohol can act as the nano-reactors which solubilize zirconium oxychloride and ammonia water separately. The minute original reactors are favor to the formation of nano-sized spherical YSZ powders and the dispersibility of the powders can be controlled effectually by adjusting the weight ratio of the LiNO3 molten salt to the precursor. The phase transformation from cubic to monoclinic starts at and 500??C and finally monoclinic and cubic phase with increased crytallinity coexist at 800??C. The effect of LiNO3 molten salt in the formation of YSZ powders was also discussed.

2008-01-01

226

Investigation of cell parameters, microstructures and electrochemical behaviour of LiMn{sub 2}O{sub 4} normal and nano powders  

Energy Technology Data Exchange (ETDEWEB)

Nano materials are usually difficult to prepare. This work presents a simple way of preparing LiMn{sub 2}O{sub 4} nano powders using the high-energy ball milling method. This method has the advantage of producing pure, single-phase and crystalline nano powders. The milling method is carefully controlled to avoid unwanted chemical reactions that may change the stoichiometry of the material. Nano powders of between 30 and 50 nm are obtained. Structural studies of the nano powders, as well as the more conventional micron-sized LiMn{sub 2}O{sub 4}, are made using X-ray diffraction and neutron diffraction methods. Electrochemical evaluation of the materials is undertaken with a three-probe cyclic voltammetry technique and galvanostatic charge-discharge measurements. Structural studies reveal that not only are the crystallites of the nano powders much reduced in size ...

2009-03-01

227

Histological analysis of 70-nm silica particles-induced chronic toxicity in mice  

British Library Electronic Table of Contents (United Kingdom)

Nano-sized silica is a promising material for disease diagnosis, cosmetics and drugs. For the successful application of nano-sized material in bioscience, evaluation of nano-sized material toxicity is important. We previously found that nano-sized silica particles with a diameter of 70nm showed acute liver failure in mice. Here, we performed histological analysis of major organs such as the liver, spleen, lung, kidney, brain and heart in mice, chronically injected with 70-nm silica particles for 4weeks. Histological analysis revealed hepatic microgranulation and splenic megakaryocyte accumulation in these 70-nm silica particles treated mice, while the kidney, lung, brain and heart remained unaffected. Thus, liver and spleen appear to be the major target organs for toxicity by the chronic a...

2009-01-01

228

Hard Corrosion and Radiation-Resistant Coatings  

International Science & Technology Center (ISTC)

Hard Nano-Strutural Coatings Resistant to the Extreme Conditions of Chemical, Abrasive and High Energy Media for Thermonuclear Power, Oil and Gas and Chemical Industries

231

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...

2006-03-01

233

Formation of nano-sized particles of a solid electrolyte by laser ablation  

Energy Technology Data Exchange (ETDEWEB)

Nano-sized particles of a lithium ion conductive solid electrolyte, LiTi{sub 2}(PO{sub 4}){sub 3}, were prepared by laser ablation. The obtained particles were ca. 10nm in diameter. X-ray powder diffraction and Raman spectroscopy showed that they were amorphous with local structure similar to the crystalline counterpart. They were crystallized by the heating at ca. 630{sup o}C. (author)

2005-08-26

234

Conductance quantization in ferromagnetic Ni nano-constriction  

Energy Technology Data Exchange (ETDEWEB)

The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.

2002-02-01

235

Utilization of smooth models for seismic data tomographic inversion  

Energy Technology Data Exchange (ETDEWEB)

Reflection tomography allows in theory the determination of the velocity distribution and the reflector geometries in the subsurface from the travel times of the seismic waves. The solution of the inverse problem is the model (velocity distribution and reflectors) that minimizes the misfits between observed travel times and travel times computed by raytracing (the forward problem). Two representations of the velocity field are generally used: blocky models (discontinuous) and smooth models. The object of this thesis is the study of tomography with smooth models which offer interesting properties at a practical level as well as at a mathematical and numerical level. We propose an original formulation of the inverse problem which allow the integration of a priori information adapted to smooth models. This formulation assures the existence, the uniqueness and the stability of the solution of the linearized inverse problem. The ...

1995-03-01

236

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ...

2003-11-01

237

Sintering of nano-sized WC-Co powders produced by a gas reduction-carburization process  

Energy Technology Data Exchange (ETDEWEB)

Nanocrystalline cemented tungsten carbide has attracted considerable interests for use in cutting tool because of its superior mechanical properties. In this study, nano-sized powders of mixed WC and Co were prepared from attrition-milled oxides by a gas reduction-carburization process. The effects of compacting pressure, heating schedule, additional ball-milling, and the presence of a grain growth inhibitor on the sintering properties of the nano-sized WC-Co powders were examined. The grain size and phases in WC-Co alloy were clearly affected by compacting pressure. Because of the trapped gases and the lower melting point of the cobalt binder, when a compact of nano-sized WC-Co powder was sintered through a heating schedule with holding steps, the sintered alloy maintained the small size of WC grains without any {eta} phase. In addition, the additional ball-milling improved the microstructure and mechanical properties of ...

2006-08-10

238

Sintering of nano-sized WC-Co powders produced by a gas reduction-carburization process  

International Nuclear Information System (INIS)

Nanocrystalline cemented tungsten carbide has attracted considerable interests for use in cutting tool because of its superior mechanical properties. In this study, nano-sized powders of mixed WC and Co were prepared from attrition-milled oxides by a gas reduction-carburization process. The effects of compacting pressure, heating schedule, additional ball-milling, and the presence of a grain growth inhibitor on the sintering properties of the nano-sized WC-Co powders were examined. The grain size and phases in WC-Co alloy were clearly affected by compacting pressure. Because of the trapped gases and the lower melting point of the cobalt binder, when a compact of nano-sized WC-Co powder was sintered through a heating schedule with holding steps, the sintered alloy maintained the small size of WC grains without any #eta# phase. In addition, the additional ball-milling improved the microstructure and mechanical properties of ...

2006-08-10

239

Micro and nano patterning by focused ion beam enhanced adhesion  

International Nuclear Information System (INIS)

We report a new method of generating nano and micro patterns using focused ion beam (FIB) induced adhesion. The method utilizes selective irradiation of thin metallic films grown on substrates by focused ion beam followed by peel off. After peel off of the irradiated thin film it is observed that the ion beam scanned portions are retained on the substrate, creating nano and micro patterns. The method is suitable for materials of which the adhesion to the substrate can be improved by ion bombardment. The phenomenon has been demonstrated by creating gold nano patterns of different shapes and sizes ranging from 500 nm to 5 #mu#m on SiO_2-Si substrate using 10-30 keV Ga FIB at beam currents up to 10 pA. The mechanism involved in the process has been discussed. The technique could be utilized to prepare micro and nano patterns of thin films deposited on an appropriate substrate for optical, plasmonic and ...

2009-05-01

240

Enhanced biosorptive removal of cadmium from aqueous solutions by silicon dioxide nano-powder, heat inactivated and immobilized Aspergillus ustus  

British Library Electronic Table of Contents (United Kingdom)

Heat inactivated Aspergillus ustus (Asp), silicon dioxide-nano-powder (N Si), and silicon dioxide nano-powder-combined-heat inactivated Aspergillus ustus (N Si Asp) were used to study the biosorption of Cd(II) from aqueous solutions via batch equilibrium technique. Surface characterization and immobilization of the fungal cells on silicon dioxide-nano-powder were examined and confirmed by using FT-IR and ESM analysis. Cadmium biosorption processes were investigated under the effect of pH, contact time, sorbent dosage and initial metal concentration. The three examined sorbents were found to exhibit maximum mmolg^-^1 capacity values in pH 7.0. The maximum determined cadmium capacity by silicon dioxide-nano-powder (N Si) (600mmolg^-^1) was found higher than that exhibited by the heat inactiv...

2011-01-01

241

[Computed tomography in gunshot trauma. I. Ballistics elements and the mechanisms of the lesions].  

Science.gov (United States)

The knowledge of wound ballistics and of wounding mechanisms is mandatory for the radiologist to interpret the CT findings of gunshot wounds. The severity of a bullet wound depends on the characteristics of the tissue it goes through, i.e., tissue elasticity, density, thickness of the wounded body part, the type of tissue, its specific gravity, internal cohesiveness and anatomical relationships, as well as on missile characteristics, i.e., mass, shape, fragmentation and deformation. Bullet velocity is certainly a major factor in wounding, but it is only one factor. Two major wounding mechanisms exist the crushing of the bullet-struck tissue (forming the permanent cavity) and radial stretching (forming a temporary cavity). Bullet "yaw" is defined as the angle between the long axis of the bullet and its flight path. The yaw is directly proportional to tissue crushing and stretching: the wider the yaw, the most severe tissue crushing and stretching and, therefore, the more severe tissue ...

1995-04-01

242

Void fraction estimation within rod bundles based on three-fluid model and comparison with X-ray CT void data  

Energy Technology Data Exchange (ETDEWEB)

An interfacial shear stress equation in the dispersed-annular two-phase flow regime has been developed, which is based on a three-fluid model consisting of a liquid film on a rod, vapor and entrained liquid associated with a vapor flow. It is an extension of J.G.M. Andersen's procedure that provides a two-fluid interfacial shear stress equation using the drift flux parameters C{sub 0} and V{sub gj}. This interfacial shear stress equation can take into account a phase and velocity distribution through an equivalence between the drift flux parameters and the interfacial shear stress. Using the three-fluid subchannel analysis code TEMPO with the three-fluid interfacial shear stress model the capability of a three-fluid calculation using the drift flux parameters C{sub 0} and V{sub gj} that reproduce a measured void fraction is demonstrated. A comparison was made with advanced X-ray computed tomography (CT) void fraction data within a 4x4 ...

1990-06-01

243

Value of micro-CT as an Investigative Tool for Osteochondritis Dissecans. A preliminary study with comparison to histology  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic ...

2003-09-01

244

Value of micro-CT as an Investigative Tool for Osteochondritis Dissecans. A preliminary study with comparison to histology  

International Nuclear Information System (INIS)

Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic ...

2003-09-01

245

Transcatheter internal radiotherapy of hepatoma using radioactive iodized oil (I-131 Lipiodol)  

Energy Technology Data Exchange (ETDEWEB)

The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest that TCIR with I-131 ...

1988-04-01

246

The crescent and the periluminal halo: Two Computed Tomography signs of aortic aneurysm impending rupture?  

International Nuclear Information System (INIS)

Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo had the same frequency in the 2 groups (12.5 % and 9.5 %). Both signs were more ...

1997-01-01

247

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background subtraction of 2% of open field intensity ...

2009-05-01

248

Relationship between QRS transition zone and the interventricular septum; Using CT scan  

Energy Technology Data Exchange (ETDEWEB)

The relationship between the QRS transition zone of the standard 12-lead ECG and interventricular septum was studied. The position and the angle to the horizontal line of the interventricular septum were evaluated with computed tomography (CT) and compared to the QRS transition zone. The subjects were 36 patients with no cardiovascular diseases. The patients were divided into 3 groups according to the position of QRS transition zone: V{sub 1}-V{sub 2} (8 cases), V{sub 3}-V{sub 4} (21 cases), and V{sub 5}-V{sub 6} (7 cases). The interventricular septum on CT was directed to the anterior chest wall between V{sub 3} and V{sub 4} in all 3 groups. The mean value of the interventricular septal angle did not differ from group to group, 52.1deg for V{sub 1}-V{sub 2} group, 49.8deg for V{sub 3}-V{sub 4} group, and 48.2deg for V{sub 5}-V{sub 6}. It was concluded that the direction of the interventricular septum was not one of the major determinants of ...

1991-11-01

249

Radionuclear estimation with {sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy of recurrent hepatocellular carcinoma after non-surgical treatment  

Energy Technology Data Exchange (ETDEWEB)

{sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy, which exhibits highly specific for the diagnosis of primary hepatocellular carcinoma (HCC), was performed for recurrent HCC following non-surgical treatment. Eighty-four patients (total 351 examinations) were selected for the study. The ability of PMT scintigraphy to diagnose recurrent HCC after treatment was compared with that of computed tomography, ultrasonography and angiography. The results showed that sixty-three (75%) of 84 cases demonstrated positive findings during our follow-up period, most of the tumors initially showing positive findings remained PMT positive when they recurred and PMT studies shortly after treatment demonstrated wider tracer uptake rather than the actual tumor area. In conclusion, PMT scintigraphy for patients with HCC after non-surgical treatment exhibited high accuracy in identifying viable HCC only for tumors indicating positive findings. (author)

1997-10-01

250

Radioiodinated phenoxyacetic acid derivatives as potential brain imaging agents, 2  

International Nuclear Information System (INIS)

In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The #alpha#,#alpha#-dimethylester derivative (1e), amide derivatives (2a-c) and diamine derivatives (3a, b, 4), which were stable to hydrolysis, showed low blood activity levels following i.v. administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with ...

251

Percutaneous drainage of abdominal abcess  

Energy Technology Data Exchange (ETDEWEB)

The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. ...

2002-09-01

252

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

Energy Technology Data Exchange (ETDEWEB)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of individually measuring flow ...

1996-06-01

253

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

International Nuclear Information System (INIS)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of individually measuring flow ...

254

MRI, CT, sonography and thallium-technetium subtraction scintigraphy for the detection of parathyroid disease: a four-year experience  

International Nuclear Information System (INIS)

Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented suggest that while ...

255

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. Contrast MRI study is ...

256

Localization of abnormal parathyroid glands using thallium-201  

Science.gov (United States)

Ectopically located parathyroid adenomas may be difficult to find during initial neck exploration. They account for over 70 percent of missed adenomas found at reexploration. Preoperative localization of parathyroid adenomas would reduce unnecessary dissection and possibly reduce the number of negative results of initial neck exploration. Before reoperative parathyroid surgery is performed, some means of localization is mandatory to detect ectopic adenomas in the neck and mediastinum. Computed tomography and ultrasonography cannot effectively evaluate the mediastinum. Angiography and venous parathyroid hormone sampling are invasive, costly, and tedious to perform. We have shown that thallium-201 will accurately localize ectopic parathyroid adenomas. All 10 adenomas found in positions not immediately adjacent to the thyroid gland were detected by thallium-201 scintigraphy. One was a mediastinal adenoma resected with a median sternotomy. Our ...

1984-07-01

257

Is turbinate surgery necessary when performing a septoplasty?  

Science.gov (United States)

Many otolaryngologists perform septoplasty with or without turbinate surgery and the surgical method relies largely on the surgeon's clinical judgment. This study used computed tomography (CT) of the sinuses of 20 patients to examine the correlation between a unilateral deviated nasal septum and compensatory hypertrophy of the contralateral inferior turbinate to suggest guidelines for septal and turbinate surgery. The thickness of the mucosa and conchal bone, the projection angle of the conchal bone, and the distances between the conchal bone, and lateral nasal line and median line were measured. The volume of the inferior turbinate was measured from the three-dimensional reconstruction. Each measurement was compared with those of the nasal cavity on the contralateral and of normal control subjects. The inferior turbinate on the concave side had a significantly greater volume, including the thickness of medial mucosa and the thickness and ...

2008-11-11

258

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

International Nuclear Information System (INIS)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were well tolerated. One patient (2 %) in the ...

1999-09-01

259

Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study  

International Nuclear Information System (INIS)

Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral ...

2010-01-01

260

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium scanning has been shown to be sensitive ...

1998-06-01

261

Evaluation of craniosynostosis surgery. Technetium-99m-HMPAO SPECT cerebral blood flow study in children with craniosynostosis  

International Nuclear Information System (INIS)

Premature fusion of multiple cranial sutures has been associated with increased intracranial pressure and the potential for mental impairment. Isolated craniosynostosis, however, is considered a benign condition primarily reconstructed for aesthetic purposes. A comparative analysis, to assess the differences between pre- and post operatory cerebral perfusion of patients who underwent surgery for simple cranisynostosis, was performed using single positron emission computed tomography ''SPECT'' Images. Cerebral blood flow studies were performed using "9"9"mTc-HMPAO SPECT in children with simple cranisynotoses. The subjects were 8 children with craniosynostosis (age, 2 months-9 years). Preoperative revealed regional hypovascularity in the cerebral hemisphere in 5 cases (62%). In 6 patients the cerebral blood flow normalized or increased after craniofacial reconstruction. We demonstrated the presence of regional hypovascularity in the cerebral ...

1998-09-01

262

Diagnostic imaging and interventional radiology of the amoebic liver abscess. Personal experience; Diagnostica per immagini e radiologia interventistica degli ascessi amebici del fegato: esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.

1999-10-01

263

Diagnostic features of intrahepatic cholangiocarcinoma according to the gross type classification  

International Nuclear Information System (INIS)

Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computed tomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, incidence of lymph ...

1998-08-01

264

Computed tomography of the chest in the postoperative recurrences of bronchogenic carcinoma  

International Nuclear Information System (INIS)

The authors describe the different types of postoperative carcinoma recurrences, as seen on CT examinations of the chest, in 38 patients who underwent different surgical procedures for bronchogenic carcinoma (12 pneumonectomies, 22 lobectomies, 2 segmentectomies, and 2 atypical resections). The recurrences were classified as follows: 1) recurrence in the bronchial stump; 2) limph node enlargement; 3) recurrence in the thoracic wall; 4) recurrence in the residual lobe; 5) pleural effusion; 6) nodule in the contralateral lung. The CT findings, Correlated with those from plain chest radiographs and clinical simptoms, indicate a higher incidence of recurrences in the hilar region, either in the bronchial stump or as node after total and subtotal resection are separately analyzed. While after pneumonectomy plain chest radiographs fail to demonstrate the recurrence in most cases, so that CT is nearly always mandatory, after subtotal resection the diagnostic accuracy of conventional radiology ...

1990-01-01

265

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and cerebello-pontine angle. HRCT best depicts osseous ...

2003-03-01

266

Computed tomography (CT) in renal trauma  

International Nuclear Information System (INIS)

CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of and sometimes correctly diagnose vascular lesions, such as renal infarction, angiography remains the ...

1987-01-01

267

Computed Tomography in pulmonary cystic fibrosis  

International Nuclear Information System (INIS)

This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method than conventional radiography to identify and locate the signs of pulmonary CF. The early identification of the lesions of high prognostic value, since the early ...

1991-01-01

268

Closed loop obstructions of the small bowel: role of Computed Tomography  

International Nuclear Information System (INIS)

Small bowel obstructions can be distinguished into more simple and closed loop obstructions. The latter is a more severe condition which is often complicated by strangulation with vascular impairment, edema and intramural and mesenteric hemorrhage. Consequent arterial insufficiency rapidly leads to ischemia, infarction and necrosis. The radiologist plays a role in the early recognition of the closed loop obstruction and of any sign of strangulation. The role of CT in the diagnosis and workup of patients with suspected intestinal occlusion has been analyzed in the literature with reported 63% sensitivity, 78% specificity and 66% accuracy. CT is also capable of revealing the causes of occlusion in 73-95% of cases. The above CT signs allow to identify closed loop obstruction and also small bowel strangulation, thus supplying a valuable contribution to diagnosis and accurate preoperative evaluation. The conclusion is that CT can accurately demonstrate the presence of closed loop ...

1999-01-01

269

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of PVNS and tendinitis ...

1988-01-01

270

Analysis of the quantitative structure activity relationship of technetium-99m-labeled diaminedithiol (DADT) and propyleneamineoxime (PAO) brain blood flow analogues  

Energy Technology Data Exchange (ETDEWEB)

In the search for new brain imaging agents for use with single photon emission computed tomography (SPECT), quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and physicochemical parameters like lipophilicity, log P, molecular weight, log MW and log U/D (undissociated/dissociated), of the {sup 99m}Tc-DADT (diaminedithiol) complexes and {sup 99m}Tc-PAO (propyleneaminoxime) complexes have been analyzed. High correlations are found for both the {sup 99m}Tc-DADT complexes (r = 0.94) and for the {sup 99m}Tc-PAO complexes (r = 0.83) which are significant at 99.9 and 99.5 percentile level, respectively. These results will help the further design of better ligands for {sup 99m}Tc in brain imaging. (author).

1991-01-01

271

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, three-dimensional computer-reconstructed neutron ...

1992-03-01

272

A Two-step Intensity-modulated Radiation Therapy Method for Nasopharyngeal Cancer: The Kinki University Experience  

British Library Electronic Table of Contents (United Kingdom)

Objective The aim of this study was to analyze the clinical results of our adaptive radiation therapy scheme of a two-step intensity-modulated radiotherapy (IMRT) method for nasopharyngeal cancer (NPC) at Kinki University Hospital. Methods Between 2000 and 2007, 35 patients with Stage I-IVB NPC treated by IMRT were included. For all patients, treatment-planning computed tomography was done twice before and during IMRT to a total dose of 60-70 Gy/28-35 fractions (median 68 Gy). Chemotherapy (cisplatin 80 mg/m2/3 weeks x 1-3 courses) was given concurrently with IMRT for 31 patients. Results The 3- and 5-year overall survival rates for the 31 patients treated with concurrent chemotherapy were 88% and 83%, respectively. The 3- and 5-year loco-regional control rates for the 31 patients were 93%...

2010-01-01

273

Osteoporosis and prevention. Assessment of mineral density, geometry and biomechanics of bone by means of peripheral quantitative Computed Tomography (pQCT) in premenopausal women assuming phytoestrogens; Osteoporosi e fitoestrogeni: valutazione della densita' minerale ossea mediante tomografia computerizzata quantitativa periferica nelle donne lattoovovegetariane nella premenopausa  

Energy Technology Data Exchange (ETDEWEB)

Aim of the work was to describe the noninvasive assessment of bone mineral density, geometrical and biochemical properties in premenopausal women with dietary intake of phytoestrogens and comparison of these parameters with those of age-matched female subjects with Mediterranean dietary intake lacking in these substances. Volumetric cortical, trabecular and total mineral density and bone geometrical properties were evaluated with peripheral quantitative computed tomography (pQCT) at the distal radius of the non dominant forearm. pQCT showed higher bone mineral density (total and trabecular) and SSI values in premenopausal with dietary intake of phytoestrogens. Despite the lack of statistical significance, these preliminary results, should further support the few literature findings about the potential role of phytoestrogens consumption in preventing trabecular bone loss. However, further studies are warranted to evaluate definitively ...

2000-04-01

274

Computed tomography whole body imaging in multi-trauma: 7 years experience  

International Nuclear Information System (INIS)

AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded prospectively. ...

2006-04-01

275

Clinically silent heterotaxy with polysplenia syndrome and IVC azygous continuation draining to SVC: CT findings. Case report  

International Nuclear Information System (INIS)

Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations ...

2007-01-01

276

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 non-calcified nodules), in ...

1995-08-01

277

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 non-calcified nodules), in ...

1995-01-01

278

Fiscal 1997 report on the results of the R and D of industrial scientific technology. R and D of synergistic ceramics (R and D of corrosion prevention technology for the petroleum production system); 1997 nendo sangyo kagaku gijutsu kenkyu kaihatsu seika hokokusho. Synergy ceramics no kenkyu kaihatsu (sekiyu seisan system fushoku boshi gijutsu kenkyu kaihatsu)  

Energy Technology Data Exchange (ETDEWEB)

To heighten durability and safety of materials/parts for undersea oil drilling, the development of ceramic base materials was made by developing function harmony type process technology which harmonizes on a high grade contrary characteristics and various functions. The paper summed up the fiscal 1997 results. In the design of system formation, computational simulation technology was developed to the composite process and the diploid system. The development of multifunction simultaneous manifestation materials was trially made by the higher nano structure process. A study was made of control of microstructures of porous materials and matrix filling by the gas phase precipitation control. Proposed were selective control of grain growth from species crystals and the columnar particle orientation laminated structure of simultaneous manifestation of strength and toughness. By composite precipitation reaction control, studied were simultaneous ...

1998-03-01

279

Macular and retinal nerve fiber layer thickness in Japanese measured by Stratus optical coherence tomography  

UK PubMed Central (United Kingdom)

The purpose of this study was to determine the thickness of the macula and the retinal nerve fiber layer (RNFL) in Japanese subjects by Stratus optical coherence tomography (OCT), and to compare the...Full Text Available

2007-06-01

280

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

281

High-Speed Ultrahigh-Resolution Optical Coherence Tomography Findings in Chronic Solar Retinopathy  

UK PubMed Central (United Kingdom)

PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available

2008-01-01

282

Clinical Assessment of Mirror Artifacts in Spectral-Domain Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available

2010-07-01

283

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

284

Artery phantoms for intravascular optical coherence tomography: healthy arteries  

UK PubMed Central (United Kingdom)

We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available

285

In-situ growth of porous alumino-silicates and fabrication of nano-porous membranes  

Science.gov (United States)

Feasibility of depositing continuous films of nano-porous alumino-silicates, primarily zeolites and MCM-41, on metallic and non-metallic substrates was examined with an aim to develop membranes for separation of gaseous mixtures and also for application as hydrogen storage material. Mesoporous silica was deposited in-side the pores of these nano-porous disks with an aim to develop membranes for selective separations. Our study involves supported zeolite film growth on substrates using in-situ hydrothermal synthesis. Faujasite, Silicalite and Mesoporous silica have been grown on various metallic and non-metallic supports. Metallic substrates used for film growth included anodized titanium, sodium hydroxide treated Titanium, Anodized aluminum, and sintered copper. A non-metallic substrate used was nano-porous aluminum oxide. Zeolite film growth was characterized using Scanning Electron Microscope (AMRAY 1820) and High ...

2009-01-01

286

Using Acoustic Tomography to Monitor Deep Ocean Currents ...  

Science.gov (United States)

... 2009. Copyright belongs to the Marine Technology Society., The original document contains color images. 14. ABSTRACT ...

2010-06-01

288

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

290

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

291

Computerized tomography of the adrenal glands in the Cushing Syndrome propaedeutic  

International Nuclear Information System (INIS)

Portuguese (Mar 1983). Brazil Furlanetto, RP Abucham Filho, J. Albertotti,

1982-10-24

292

Nano silicon for lithium-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

New results for two types of nano-size silicon, prepared via thermal vapour deposition either with or without a graphite substrate are presented. Their superior reversible charge capacity and cycle life as negative electrode material for lithium-ion batteries have already been shown in previous work. Here the lithiation reaction of the materials is investigated more closely via different electrochemical in situ techniques: Raman spectroscopy, dilatometry and differential electrochemical mass spectrometry (DEMS). The Si/graphite compound material shows relatively high kinetics upon discharge. The moderate relative volume change and low gas evolution of the nano silicon based electrode, both being important points for a possible future use in real batteries, are discussed with respect to a standard graphite electrode. (author)

2006-11-12

293

Enhanced inactivation of bacteria by metal-oxide nanoparticles combined with visible light irradiation  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground In recent years nano-metaloxides which easily penetrate into the cells with special interest due to their higher chemical reactivity as compared to that of similar materials in the bulk form. Of particular interest are nano-TiO2 and ZnO, which have been widely used for their bactericidal and anticancerous properties. Purpose The aim of the present study was to examine the bactericidal properties of nano-TiO2 and ZnO combined with visible light on S. aureus and S. epidermitis, known for their high prevalence in infected wounds. Study Using the technique of electron-spin resonance (ESR) coupled with spin trapping, we examined the ability of TiO2 and ZnO nanoparticle suspensions in water to produce reactive oxygen species (ROS) with and without visible light irradiation. Th...

2011-01-01

294

A Nano-Scale Labortory For Adhesive Materials (Naslam)  

Environmental Research Database

ObjectivesFirst comprehensive evaluation of the mechanical properties of an epoxy adhesive in different environments using a nano-indenter. ~%~~%~Use AFM/SEM and finite element modelling to generate knowledge of the precise mechanism of indentation in the epoxy adhesive. ~%~~%~Develop an improved data reduction algorithm for generating meaningful mechanical property data from indentation tests for adhesive materials.~%~ ~%~Validate the nano-indentation method of generating mechanical property data against [continued...]DescriptionThis project aims to address the problem of insufficient data on adhesive materials for effective modelling of joint behaviour in different environments. The methodology to be used is based on depth sensing indentation tests at different loads and rates and in different environments. Post-indentation deformation and recovery will be monitored by AFM and SEM and the indentation ...

2003-01-04

295

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

296

Study of structural, thermodynamical and dynamical properties of molecular liquids confined in nano-porous materials  

International Nuclear Information System (INIS)

When liquids are confined in nano-scopic dimensions, their properties differ from the corresponding bulk liquid, due to their reduced dimensionality and surface effects. Phase transition temperatures and pressures are often shifted from the bulk values and new phases can appear due to the strong interactions of the molecules with the confining walls. We have studied the structural and dynamical properties of aromatic liquids such as benzene, toluene, and ortho-terphenyl confined in nano-porous materials, MCM-41 and SBA-15, synthesized and characterized in our laboratory. A non-trivial dependence of the glass transition temperature, Tg, on the pore size and surface treatment of nano-porous materials is confirmed and interpreted as resulting from a competition between the fluid-wall and fluid-fluid intermolecular interactions. An increase of Tg is observed for small pore sizes and attractive surface while Tg decreases for non ...

2006-01-01

297

Preparation of ZnO varistors by solution nano-coating technique  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces a new method to produce nano-composite powder for the preparation of high performance ZnO varistors. ZnO particles were coated with Bi{sub 2}O{sub 3}, Sb{sub 2}O{sub 3}, Co{sub 2}O{sub 3}, Cr{sub 2}O{sub 3} and other additives via liquid nano-coating technique. Then the prepared powder was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), thermal gravity and differential scanning calorimetry (TG-DSC) and particle size distribution. The results showed that the ZnO composite powder is homogeneously coated and ultrafine. The densification, phase composition and microstructure of ZnO varistors was studied by linear shrinkage, X-ray diffraction (XRD) and SEM, respectively. The preliminary electrical parameters of ZnO varistors showed that the breakdown voltage V {sub b} (1 mA/cm{sup 2}) and nonlinear coefficient {alpha} is 5400 V/cm and 50, respectively, much higher than that of ...

2006-06-15

299

Nano to micro delivery systems: targeting angiogenesis in brain tumors  

UK PubMed Central (United Kingdom)

Treating brain tumors using inhibitors of angiogenesis is extensively researched and tested in clinical trials. Although anti-angiogenic treatment holds a great potential for treating primary and secondary...Full Text Available

300

NSF Centers Will Use Nano-Interface Control and Bioengineering for Materials by Design  

Science.gov (United States)

... materials science and education beyond what is expected from any one Center. "Advanced materials are ... for DMR's Division of Materials Research. "Fundamental research on materials is essential to the ...

301

In situ nanoindentation in a transmission electron microscope  

Science.gov (United States)

This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids.

2002-12-02

302

Earth and Environment: murray_dobbie_morris  

Wastenet

... In recent years workers in this field have focused on nucleation by nano-porous materials . This was in part motivated by a theoretical study by Page and Sear (2006) who proposed a two step model for nucleation in pores which suggest that there is ...

303

Development and validation of a high performance liquid chromatography method for the simultaneous determination of aspirin and folic acid from nano-particulate systems  

UK PubMed Central (United Kingdom)

Attention has shifted from the treatment of colorectal cancer (CRC) to chemoprevention using aspirin and folic acid as agents capable of preventing the onset of colon cancer. However, no sensitive...Full Text Available

2010-09-01

304

Tomography and Methods of Travel-Time Calculation for Regional Seismic Location  

Energy Technology Data Exchange (ETDEWEB)

We are developing a laterally variable velocity model of the crust and upper mantle across Eurasia and North Africa to reduce event location error by improving regional travel-time prediction accuracy. The model includes both P and S velocities and we describe methods to compute travel-times for Pn, Sn, Pg, and Lg phases. For crustal phases Pg and Lg we assume that the waves travel laterally at mid-crustal depths, with added ray segments from the event and station to the mid crustal layer. Our work on Pn and Sn travel-times extends the methods described by Zhao and Xie (1993). With consideration for a continent scale model and application to seismic location, we extend the model parameterization of Zhao and Xie (1993) by allowing the upper-mantle velocity gradient to vary laterally. This extension is needed to accommodate the large variation in gradient that is known to exist across Eurasia and North African. Further, we extend the linear travel-time calculation ...

2007-07-02

305

Semi-automated segmentation of the sigmoid and descending colon for radiotherapy planning using the fast marching method  

International Nuclear Information System (INIS)

A fast and accurate segmentation of organs at risk, such as the healthy colon, would be of benefit for planning of radiotherapy, in particular in an adaptive scenario. For the treatment of pelvic tumours, a great challenge is the segmentation of the most adjacent and sensitive parts of the gastrointestinal tract, the sigmoid and descending colon. We propose a semi-automated method to segment these bowel parts using the fast marching (FM) method. Standard 3D computed tomography (CT) image data obtained from routine radiotherapy planning were used. Our pre-processing steps distinguish the intestine, muscles and air from connective tissue. The core part of our method separates the sigmoid and descending colon from the muscles and other segments of the intestine. This is done by utilizing the ability of the FM method to compute a specified minimal energy functional integrated along a path, and thereby extracting the colon ...

2010-09-21

306

Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur ...

2008-09-15

307

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...

1989-06-01

308

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...

1989-01-01

309

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have been well without ...

2008-04-15

310

Diagnostic imaging of Thorotrast associated cholangiocarcinoma and mixed hepatocellular and cholangiocellular carcinoma  

International Nuclear Information System (INIS)

Computed tomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests ...

311

A Network Coding Approach to Loss Tomography  

CERN Document Server

Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of ...

2010-01-01

312

Heat transfer augmentation of a circular pipe flow using nano-particle layers  

International Nuclear Information System (INIS)

For the advanced fusion reactor FFHR2 (Force Free Helical Reactor) that has been proposed by NIFS, molten salt Flibe (LiF:BeF2=64:36) breeder blanket system is selected because of Flibe's features such as chemical stability, low-pressure operation and low electric conductivity. The Flibe is however high Prandtl number fluid since it has high viscosity and low thermal conductivity. Therefore its heat transfer performance is low compared with liquid Li or Pb-Li. In addition to heat removal of 1MW/m2 on the first wall, electrolysis of molten salt due to MHD effect will take place under high flow rate condition. This indicates that heat transfer enhancement under low flow rate is essential for the Flibe blanket system. In our laboratory, heat transfer characteristics of molten salt HTS (KNO3:NaNO2:NaNO3=53:40:7), have been evaluated, which is used as a simulant fluid of Flibe from the points of view of Be's toxicity and similar Prandtl number. In ...

2007-10-05

313

The crack of harden cement paste observed with multi-technique  

British Library Electronic Table of Contents (United Kingdom)

The shrinkage of the cement paste with low water-cement ratio at different relative humidity was observed and analyzed with ESEM and deformation map technique. The crack morphology was observed with different magnification with SEM and FESEM, and the formation of the crack was observed with AFM between two C-S-H nano particles. The observation by multi technique at multi scale indicated that the shrinkage was increase with the decrease of the humidity due to the increase of the pressure of the capillary pressure, the morphology of the crack in smaller scale was similar to that in the bigger scale, the smaller crack distributed in the latticework of the bigger ones, and the crack propagated along the gap between two nano particles of C-S-H with weaker bonding.

2010-01-01

314

Large-area metallic photonic lattices for military applications.  

Energy Technology Data Exchange (ETDEWEB)

In this project we developed photonic crystal modeling capability and fabrication technology that is scaleable to large area. An intelligent optimization code was developed to find the optimal structure for the desired spectral response. In terms of fabrication, an exhaustive survey of fabrication techniques that would meet the large area requirement was reduced to Deep X-ray Lithography (DXRL) and nano-imprint. Using DXRL, we fabricated a gold logpile photonic crystal in the <100> plane. For the nano-imprint technique, we fabricated a cubic array of gold squares. These two examples also represent two classes of metallic photonic crystal topologies, the connected network and cermet arrangement.

2007-11-01

315

Hydrogen storage in nano-structured carbon materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...

2005-07-01

316

Hydrogen storage in nano-structured carbon materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...

2005-07-01

317

Investigation on corrosion and wear behaviors of nanoparticles reinforced Ni-based composite alloying layer  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate the role of amorphous SiO{sub 2} particles in corrosion and wear resistance of Ni-based metal matrix composite alloying layer, the amorphous nano-SiO{sub 2} particles reinforced Ni-based composite alloying layer has been prepared by double glow plasma alloying on AISI 316L stainless steel surface, where Ni/amorphous nano-SiO{sub 2} was firstly predeposited by brush plating. The composition and microstructure of the nano-SiO{sub 2} particles reinforced Ni-based composite alloying layer were analyzed by using SEM, TEM and XRD. The results indicated that the composite alloying layer consisted of {gamma}-phase and amorphous nano-SiO{sub 2} particles, and under alloying temperature (1000 deg. C) condition, the nano-SiO{sub 2} particles were uniformly distributed in the alloying layer and still kept the amorphous structure. The corrosion resistance of composite ...

2008-04-30

318

Investigation on corrosion and wear behaviors of nanoparticles reinforced Ni-based composite alloying layer  

International Nuclear Information System (INIS)

In order to investigate the role of amorphous SiO2 particles in corrosion and wear resistance of Ni-based metal matrix composite alloying layer, the amorphous nano-SiO2 particles reinforced Ni-based composite alloying layer has been prepared by double glow plasma alloying on AISI 316L stainless steel surface, where Ni/amorphous nano-SiO2 was firstly predeposited by brush plating. The composition and microstructure of the nano-SiO2 particles reinforced Ni-based composite alloying layer were analyzed by using SEM, TEM and XRD. The results indicated that the composite alloying layer consisted of ?-phase and amorphous nano-SiO2 particles, and under alloying temperature (1000 deg. C) condition, the nano-SiO2 particles were uniformly distributed in the alloying layer and still kept the amorphous structure. The corrosion resistance of composite alloying layer was investigated by an ...

2008-04-30

319

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung  

Energy Technology Data Exchange (ETDEWEB)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...

2003-03-01

320

Nephron-sparing percutaneous ablation of a 5 cm renal cell carcinoma by superselective embolization and percutaneous RF-ablation  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 weeks after the radiofrequency ...

2001-11-01

321

Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations  

International Nuclear Information System (INIS)

The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each dose calculation algorithm, patient, and beam quality, the following set of clinically relevant dose-volume ...

2006-09-01

322

Computerized tomography of adrenal glands in the investigation of Cushing's syn  

International Nuclear Information System (INIS)

Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author).

323

Temperature-dependent properties of semiconductor quantum dots in coherent regime; Temperaturabhaengige Eigenschaften einzelner Halbleiter-Quantenpunkte im Kohaerenten Regime  

Energy Technology Data Exchange (ETDEWEB)

Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). Transitions between the ...

2009-10-15

324

Shape control of CeO{sub 2} nano-particles and synthesis of nano-metric solid acid SO{sub 4}{sup 2-}/CeO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Nano-particles of CeO{sub 2} with the smallest average particle size (18.7 nm) and spherical morphology were obtained from a mixture solution of Ce(NO{sub 3}){sub 3}{center_dot}6H{sub 2}O, citric acid, polyvinyl alcohol by an auto-combustion process exploiting sol-gel as precursors. The course of size control and shape control by polyvinyl alcohol was examined in detail. A transmission electron microscopy (TEM) and an atomic force microscopy (AFM) were employed to characterize the particle-size and morphology of CeO{sub 2} particles. In addition, a sort of nano-metric solid acid SO{sub 4}{sup 2-}/CeO{sub 2} based on CeO{sub 2} nano-particles was prepared by macerating, filtering, drying and calcining processes. The particle-size of SO{sub 4}{sup 2-}/CeO{sub 2} was also assessed by TEM. The composition of SO{sub 4}{sup 2-}/CeO{sub 2} was analyzed by X-ray diffraction (XRD) and infrared spectra (IR). The influencing factors ...

2003-12-20

325

Focus ion beam preparation of transmission electron microscope sample in polymer clay nano composite  

International Nuclear Information System (INIS)

This paper deals with preparation of PE clay nano composite specimen for transmission electron microscopy (TEM) and studying the difference between dispersion of clay in low density polyethylene using poly(hydrogen methyl siloxane) (PHMS) as coupling agent and untreated one. Argon ion milling is the conventional means by which film sections are thinned to electron transparency for TEM analysis, but this technique exhibits significant problems. In particular, selective thinning and imaging of sub-micrometer inclusions during sample milling are highly problematic. We have achieved successful results using the focused ion beam (FIB) lift-out technique, which utilizes a 30 kV Ga"+ ion beam to extract electron transparent specimens with nanometer scale precision. Using this procedure, we have prepared a number of thin film materials representing a range of structures and compositions for TEM analysis. We believe that FIB milling will create major new opportunities in ...

2006-01-01

326

Transurethral Ultrasound Diffraction Tomography  

Science.gov (United States)

... [5] GT Gullberg, RH Huesman, DNG Roy, J. Qi and BW Reutter, Esti- mation of the parameter covariance matrix for a one-compartment cardiac ...

2007-03-01

328

Quantitative cerebral blood flow with Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available

2010-02-01

332

The crescent and the periluminal halo: Two Computed Tomography signs of aortic aneurysm impending rupture?; La semiluna e l`alone periluminale: Due segni con Tomografia Computerizzata di aneurisma aortico a rischio di rottura?  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo had the same frequency in the 2 groups (12.5 % and 9.5 %). Both signs were more ...

1997-04-01

333

Status of lead and bismuth for radioimmunoimaging and radioimmunotherapy  

International Nuclear Information System (INIS)

Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or "2"1"2Pb could serve as sources for highly cytocidal ...

1990-08-26

334

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear ...

1985-06-02

335

Respiratory impairment due to asbestos exposure in brake-lining workers  

International Nuclear Information System (INIS)

There is extensive evidence that exposure to asbestos causes pulmonary parenchyma fibrosis, pleural disease, and malignant neoplasm in asbestos-exposed workers. However, few data concerning brake-lining workers are available in the literature. In this study, we aimed to assess the long-term effects of chrysotile asbestos exposure on lung function and the risk of asbestos-related diseases in brake-lining workers. Seventy-four asbestos-exposed workers who processed brake-lining products and 12 unexposed office workers were offered pulmonary function tests (spirometry and transfer actor) in 1992 and 1999. In 1999, the mean duration of asbestos exposure was 0.00#+-#4.07 and 11.02#+-#4.81 years (7-31 years) in non smoking and smoking asbestos workers, respectively. Transfer factor (T_L, CO) and transfer coefficient (K_C_O) decline were significant in the 7-year follow-up in both smoking and non smoking asbestos workers. However, lung function indices of he control group, whom were all ...

2003-03-01

336

Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico  

Energy Technology Data Exchange (ETDEWEB)

To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, ...

2001-07-01

337

Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two ...

2010-08-01

338

Preoperative staging of rectal carcinoma with combined sonography and pelvic computed tomography  

International Nuclear Information System (INIS)

The accurate staging of rectal carcinoma is very important for treatment planning. The histological data obtained from surgical specimens of 22 patients with rectal carcinoma were compared with pre-and postoperative endorectal US findings and with preoperative CT results. According to an adapted version of Astler and Coller classification, the different degrees of tumor spread into the rectal wall were represented as follows: stage A: 1 patient; stage B1: 5 patients; stage B2: 6 patients; stage C1: 1 patient; stage C2: 8 patients and stage D: 1 patient. Preoperative staging, based on the overall results of CT and US, was in agreement with histology in 19 of 22 cases. Individual analysis of US and CT results, in comparison with histological data, showed US staging accuracy to be 77.3% (17/22 patients). US accuracy in demonstrating tumor spread into the rectal wall (stages A, B1, C1) was 100% (7/7 patients); US was 70% accurate in lymph node detection (7/10 patients) and 93.3% accurate ...

1991-01-01

339

Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings  

International Nuclear Information System (INIS)

Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One ...

2008-08-01

340

Performance of Brazilian thermoluminescent CaSO{sub 4}: Dy pellets in standard diagnostic radiology beams  

Energy Technology Data Exchange (ETDEWEB)

The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in diagnostic beams. In this study, a large energy ...

2006-07-01

341

Osteonecrosis of the hip joint in adults; Die Osteonekrose des Hueftgelenks im Erwachsenenalter  

Energy Technology Data Exchange (ETDEWEB)

Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computed tomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten bei der ON wurden in den letzten Jahren durch technische ...

2002-06-01

342

Mucociliary transport and upper airway disease  

International Nuclear Information System (INIS)

Mucociliary transport so critical in nasal, paranasal sinus, and middle ear physiology is impaired in chronic sinsusitis and otitis media by factors such as increased mucus viscoelasticity, decreased ciliary area, and primary or secondary ciliary immotility. We reviewed the pathophysiology of primary ciliary dyskinesia, otitis media with effusion, chronic sinusitis, and allergic rhinitis in terms of mucociliary transport. Subjects with primary ciliary dyskinesia may experience recurrent middle ear infection, chronic airway infection, predominantly lower-lobe bronchiectasis, male sterility, or situs inversus. Primary ciliary dyskinesia is sometimes difficult to diagnose in cases without situs inversus. Nasal nitric oxide concentration in such patients decreases, although why is unclear. Mutations may involve dynein arm intermediate chain 1 (DNAI1) or dynein arm heavy chain 5 (DNAH5). Mucociliary clearance decreases more in those with otitis media with effusion than in those without, due ...

2010-05-01

343

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator  

International Nuclear Information System (INIS)

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to the bone ribs were not fully taken into ...

2007-05-01

344

Lesion localization in patients with hyperparathyroidism using double-phase Tc-99m MIBI parathyroid scintigraphy  

International Nuclear Information System (INIS)

This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of ...

1999-02-01

345

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

Energy Technology Data Exchange (ETDEWEB)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were well tolerated. One patient (2 %) in the ...

1999-09-01

346

Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally ...

2003-04-01

347

Image-guided pleural biopsy: diagnostic yield and complications  

International Nuclear Information System (INIS)

Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following ...

2006-08-01

348

Graft copolymers of methyl methacrylate and poly([R]-3-hydroxybutyrate) macromonomers as candidates for inclusion in acrylic bone cement formulations: Compression testing.  

Science.gov (United States)

Graft copolymers of methyl methacrylate and biodegradable, biocompatible bacterial poly([R]-3-hydroxybutyrate) (PHB) blocks were synthesized and evaluated as possible constituents in acrylic bone cements for use in orthopaedic applications. The copolymers were produced by conventional free radical copolymerization and incorporated in one commercially available acrylic bone cement brand, Antibiotic Simplex (AKZ). Cements with formulations containing 6.7 and 13.5 wt % of PMMA-graft-PHB were prepared. The morphology of the graft copolymer particles was suggested to influence the ability of the modified cement to be processed. Formulations containing more than about 20 wt % of the graft copolymer resulted in cement doughs that, both after first preparation and several hours later, were either sandy or soft spongy in texture and, thus, would be unacceptable for use in orthopaedic applications. The morphologies of the powders and the volumetric porosity (p) and ultimate compressive strength ...

2006-04-01

349

Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively 10/15 (67%) and 9/15 (60%) polyps {>=}10 mm, with 5 and 8 ...

2007-12-15

350

Endobronchial ultrasound with transbronchial needle aspiration for restaging the mediastinum in lung cancer  

DEFF Research Database (Denmark)

Purpose To investigate the sensitivity and accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for restaging the mediastinum after induction chemotherapy in patients with non-small-cell lung cancer (NSCLC). Patients and Methods One hundred twenty-four consecutive patients with tissue-proven stage IIIA-N2 disease who were treated with induction chemotherapy and who had undergone mediastinal restaging by EBUS-TBNA were reviewed. On the basis of computed tomography, 58 patients were classified as having stable disease and 66 were judged to have had a partial response. All patients subsequently underwent thoracotomy with attempted curative resection and a lymph node dissection regardless of EBUS-TBNA findings. Results Persistent nodal metastases were detected by using EBUS-TBNA in 89 patients (72%). Of the 35 patients in whom no metastases were assessed by EBUS-TBNA, 28 were found to have residual stage IIIA-N2 ...

2008-01-01

351

Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience  

International Nuclear Information System (INIS)

Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the absence of enhancement when compared to prone ...

2009-09-01

352

Development of regional cerebral blood flow during childhood studied with Iodine-123-IMP SPECT  

International Nuclear Information System (INIS)

Regional cerebral blood flow (rCBF) was assessed with single photon emission computed tomography (SPECT), "1"2"3I-N-isopropyl-iodoamphetamine ("1"2"3I-IMP), and the Table-Look-Up method in 51 children (27 boys, 24 girls) considered neurologically normal and aged 1 month to 15 years (mean age, 4 years 1 month; standard deviation (SD) 3 years 11 months) divided into seven age groups. The rCBF was measured in cortical regions, the cerebellum, thalamus, and the head of the caudate nucleus. Curves for reference values and standard deviations were defined for each region. The rCBF rapidly increased until 2 years of age, reaching maximum values during the third to fifth periods (2 to 10 years of age) in each region. The rCBFs then decreased, reaching adult levels at 10 to 15 years of age. The rCBF reached maximum values later in the frontal region than in other regions. The rCBF during the early period increased most prominently in the occipital ...

2006-06-01

353

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

Energy Technology Data Exchange (ETDEWEB)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup 11} n*cm{sup 2}/s. This facility will be based on a conical neutron collimator with two circular ...

2009-07-01

354

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

International Nuclear Information System (INIS)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 n*cm2/s. This facility will be based on a conical neutron collimator with two circular diaphragms with ...

2009-06-07

355

Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?  

Energy Technology Data Exchange (ETDEWEB)

(1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular ...

2007-02-15

356

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted images. As for lesions <2 cm, Gd-DTPA ...

1991-01-01

357

Comparative adequacy of conventional radiography, ultrasonography and Computed Tomography in twenty-six consecutive patients with acute superior mesenteric ischemia  

International Nuclear Information System (INIS)

Ischemic bowel disease is a rare disorder whose incidence is increasing as the mean age of the population increases. Diagnosis by clinical, laboratory and radiologic means is often difficult, and delay in definitive therapy results in substantial morbidity and mortality. A series of 26 consecutive patients, with proved acute superior mesenteric ischemia, was retrospectively reviewed: the authors reports the diagnostic methods performed preoperatively, the site and the cause of infarction and the time passed between the first radiograph and surgery. Plain abdominal radiographs were performed in 25 of 26 patients, screening abdominal US in 23 cases and CT in 19 cases. All radiological examinations were retrospectively reviewed by the three authors, independently, to recognize the different signs of infarction. On plain abdominal films, the findings warranting a presumptive diagnosis of bowel infarction were air-fluid levels (84% of cases), dilated bowel loops (48%), thickened and ...

1997-01-01

358

Comparative accuracy of Computed Tomography and lymphoangiography in detecting lymph node metastases from epithelial cancer of the ovary  

International Nuclear Information System (INIS)

The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% positive predictive value, and 84.6% vs 81.5% negative predictive value. In the second ...

1991-01-01

359

CT colonography: interpretative performance in a non-academic environment  

Energy Technology Data Exchange (ETDEWEB)

Aim: To investigate interpretative accuracy and reporting time for radiologists performing computed tomography (CT) colonography in day-to-day non-academic clinical practice. Materials and methods: Thirteen radiologists from seven centres, who were reporting CT colonography in non-academic daily clinical practice, interpreted a dataset of 15 colonoscopically validated cases in a controlled environment. Ten cases had either a cancer or polyp >10 mm; one case had a medium polyp and four were normal. Correct case categorization and interpretation times were compared using analysis of variance to aggregated results obtained from both experienced observers and observers recently trained using 50 cases, working in an academic environment. The effect of experience was determined using Spearman's rank correlation. Results: Individual accuracy was highly variable, range 53% (95% CI 27-79%) to 93% (95% CI 68-100%). Mean accuracy overall ...

2007-05-15

360

Assessment of arterial tumor vascularity in small hepatocellular carcinoma. Comparison between color Doppler ultrasonography and radiographic imagings with contrast medium: dynamic CT, angiography, and CT hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and ...

2000-10-01

361

Application of neutron radiography systems in JRR-3M to nuclear engineering  

Energy Technology Data Exchange (ETDEWEB)

Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void fraction distributions around tie spacers. RNR has been used ...

1999-07-01

362

Anatomic variations on PNS CT  

Energy Technology Data Exchange (ETDEWEB)

To illustrate frequently encountered anatomic variations on PNS computed tomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second group included Onodi cell(1.4%) and ...

1994-09-15

363

Anatomic variations on PNS CT  

International Nuclear Information System (INIS)

To illustrate frequently encountered anatomic variations on PNS computed tomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second group included Onodi cell(1.4%) and medial ...

1994-09-01

364

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography  

International Nuclear Information System (INIS)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower lobe. Bilateral reticular interstitial ...

2000-06-01

365

A study on the mineral density of the lumbar vertebral bone in children of metabolic disorders and control using single energy quantitative CT  

Energy Technology Data Exchange (ETDEWEB)

A cross sectional study on the mineral density of the 3rd lumbar vertebral trabecular bone was carried out in 123 children less than 15 years old, comprising 44 controls, and 79 patients affected with conditions which are at risk for developing metabolic derangement of skeletal bone (34 patients taking antiepileptic drugs (AED), 29 undergoing glucocorticoid (GC) therapy and 16 bedridden patients), by using quantitative computed tomography (QCT) with a CaCO{sub 3} phantom. Serum Ca and alkaline-phosphatase (Alp) levels were measured at the time of QCT examinations in all. The results obtained were as follows: The QCT values in the control children showed neither age dependency nor a sexual difference before puberty. The QCT values in each group showed significant difference with one another; the control group>the AED group>the GC group>the bedridden group (p<0.05{approx}0.005). The serum Ca levels in each pathology group were ...

1991-06-01

366

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...

2009-03-07

367

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed CT ...

2004-12-07

368

10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography  

Energy Technology Data Exchange (ETDEWEB)

CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The discrimination between pancreatic head ...

1990-10-15

369

10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography  

International Nuclear Information System (INIS)

CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The discrimination between pancreatic head from ...

1990-10-01

370

Spark plasma sintered tantalum carbide: Effect of pressure and nano-boron carbide addition on microstructure and mechanical properties  

British Library Electronic Table of Contents (United Kingdom)

TaC and TaC-1wt.% B4C powders were consolidated using spark plasma sintering (SPS) at 1850^oC and varying pressure of 100, 255 and 363MPa. The effect of pressure on the densification and grain size is evaluated. The role of nano-sized B4C as sintering aid and grain growth inhibitor is studied by means of XRD, SEM and high resolution TEM. Fully dense TaC samples were produced at a pressure of 255MPa and higher at 1850^oC. The increasing pressure also resulted in an increase in TaC grain size. Addition of B4C leads to an increase in the density of 100MPa sample from 89% to 97%. B4C nano-powder resists grain growth even at high pressure of 363MPa. The formation of TaB2/Carbon at TaC grain boundaries helps in pinning the grain boundary and inhibiting grain growth. The effect of B4C addition on...

2011-01-01

371

Report on the project on the researcher dispatch type international joint research survey. Feasibility study for digging up the seeds for international joint research; Kenkyusha hakengata kokusai kyodo kenkyu chosa jigyo hokokusho. Kokusai kyodokenkyu sizu hakkutsu no tameno FS chosa  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of digging up themes of the joint research which develop the R and D in the industrial technology field in Japan to a new stage, researchers were sent to the world representing research institutes to conduct the research survey of 'Nano-structured carbon and hydrogen absorption' and 'Development of the creation technology of nano-porous materials.' As to the former, an experiment on electrochemical hydrogen absorption of carbon materials including nanotubes was conducted by researchers dispatched, but the large absorption amount was not observed. As to the latter, visits were paid to Fraunhofer Institute and the related facilities in Germany, Princeton University, MIT, GIT and Naval Research Laboratories in the U.S., Orleans University in France, AO Research Institute (bone repair study) in Switzerland, Cambridge University and University of Bristol in the U.K., etc., and the research survey ...

2001-03-01

372

Nano-engineered PtVFe catalysts in proton exchange membrane fuel cells: Electrocatalytic performance  

International Nuclear Information System (INIS)

Proton exchange membrane fuel cells (PEMFCs) are attractive because of their high conversion efficiency, low pollution, lightweight, and high power density. A major area of challenges is the design and engineering of active, robust, and low-cost electrocatalysts. This report discusses recent findings of our investigations of the design and nano-engineering of platinum-vanadium-iron catalysts for use in PEMFC. The membrane electrode assembly was prepared using nano-engineered PtVFe nanoparticles with controlled composition and size supported on carbon as cathode electrocatalysts. The electrocatalytic activity and stability of the catalysts have been characterized by both rotating disk electrode and membrane electrode assembly measurements. The trimetallic catalysts have been shown to exhibit excellent electrocatalytic performance in PEMFC in comparison with commercial platinum catalysts. The results exhibited a good agreement between obtained ...

2010-11-30

373

Magnetic nanoparticle detection using nano-SQUID sensors  

International Nuclear Information System (INIS)

We demonstrate detection of a single core-shell magnetite-silica nanoparticle (outer diameter #approx#120 nm, moment #approx#10"4#mu#_B) using an Nb dc superconducting quantum interference device (SQUID) with the loop size of 350 nm operational at T < 10 K. The system noise was minimized down to 0.2 #mu##PHI#_0 Hz"-"1"/"2 using a cryogenic SQUID series array pre-amplifier. Initial measurements of an individual magnetic nanoparticle were performed and a clear change of the noise spectra of the nano-SQUID was detected at low frequencies in the presence of the nanoparticle. Similar behaviour was confirmed with an FePt nanoparticle with a larger magnetic moment (diameter #approx#150 nm, moment #approx#10"6#mu#_B). Thus, we demonstrate a magnetic sensor based on a dc nano-SQUID and enabling detection of small moments (potentially down to a few electron spins). Such a sensor is of considerable significance for nanomagnetic metrology and quantum ...

2010-12-01

374

Evaluating the cytotoxicity of palladium/magnetite nano-catalysts intended for wastewater treatment  

International Nuclear Information System (INIS)

Palladium/magnetite nanoparticulate catalysts were developed for efficient elimination of halogenated organic pollutants from contaminated wastewater. Particle recovery from treated water can be ensured via magnetic separation. However, in worst-case scenarios, this catalyst removal step might fail, leading to particle release into the environment. Therefore, a toxicological study was conducted to investigate the impact of both pure magnetite and palladium/magnetite nanoparticle exposure upon human skin (HaCaT) and human colon (CaCo-2) cell lines and a cell line from rainbow trout gills (RTgill-W1). To quantify cell viability after particle exposure, three endpoints were examined for all tested cell lines. Additionally, the formation of reactive oxygen species was studied for the human cells. The results showed only minor effects of the particles on the tested cell systems and support the assumption that palladium/magnetite nano-catalysts can be implemented for a ...

2010-01-01

375

Enhancing compressive response of AZ31B using nano-Al2O3 and copper additions  

British Library Electronic Table of Contents (United Kingdom)

In the present study, new light weight nano-composites (AZ31B-3.3Al2O3-Cu) based on magnesium alloy AZ31B are developed using disintegrated melt deposition technique. Microstructural characterization studies revealed grain refinement and significant increase in amount of second phases as a result of increasing presence of copper. All the samples exhibited minimal porosity and good matrix-second phase interfacial integrity. The results also showed that addition of both nano-Al2O3 and Cu led to a simultaneous improvement in 0.2% yield compressive strength (0.2%YCS), ultimate compressive strength (UCS) and work of fracture (WoF) of the AZ31B magnesium alloy while failure strain was marginally affected. The results of this study clearly illustrate the capability of AZ31B-Al2O3-Cu formulations ...

2010-01-01

376

Calculation of diffusion coefficients of TEABF{sub 4} in acetonitrile by means of the single particle micro-electrode technique.  

Energy Technology Data Exchange (ETDEWEB)

A single particle micro-electrode technique has been applied, to study adsorption and mass transport phenomena of a TEABF{sub 4}/acetonitrile solution in a nano-porous carbon. The nano-porous carbon, which is obtained from SiC, has a very small and narrow pore size distribution around 8 Angstrom. Therefore, it is a good model material for studying adsorption processes in micropores. The results from cyclic voltammetry showed that a higher specific capacitance was obtained in the positive potential interval (vs Ag/AgNO{sub 3}). Upon activation cycling the mass transport inside the nano-porous particle becomes drastically hindered, probably by TEA{sup +} that is adsorbed and is partially blocking the micropores. Effective diffusion coefficients, Deff, were determined from potential step experiments. At positive potentials Deff was 1.5 {+-} 0.5 x 10{sup -8} cm{sup 2}s{sup -1}, whereas at more negative potentials Deff decreased ...

2004-07-01

377

Assembly of Linear Nano-Chains from Iron Oxide Nanospheres with Asymmetric Surface Chemistry  

Science.gov (United States)

Besides the multifunctionality, another equally important aspect of nanoparticles is their engineerability to control the geometrical and chemical properties during fabrication. In this work, we exploited this aspect to define asymmetric surface chemistry of an iron oxide nanosphere by controlling the topology of ligand expression on its surface resulting in a particle with two faces, one displaying only amines and the other only thiols. Specifically, amine-functionalized iron oxide nanospheres were attached on a solid support via a crosslinker containing a disulfide bridge. Liberation of the nanosphere using thiolytic cleavage created thiols on the portion of the particle's surface that interacted with the solid support. Employing a solid-phase strategy and a step-by-step addition of particles, the two unique faces on the same nanosphere served as fittings to assemble them into linear nano-chains. Assembly of chains with various lengths and aspect ratios was ...

2011-01-06

378

Neurotoxicity of low-dose repeatedly intranasal instillation of nano- and submicron-sized ferric oxide particles in mice  

International Nuclear Information System (INIS)

Olfactory tract has been demonstrated to be an important portal for inhaled solid nanoparticle transportation into the central nervous system (CNS). We have previously demonstrated that intranasally instilled Fe_2O_3 nanoparticles could transport into the CNS via olfactory pathway. In this study, we investigated the neurotoxicity and size effect of repeatedly low-dose (130 #mu#g) intranasal exposure of nano- and submicron-sized Fe_2O_3 particles (21 nm and 280 nm) to mice. The biomarkers of oxidative stress, activity of nitric oxide synthases and release of monoamine neurotransmitter in the brain were studied. Our results showed that significant oxidative stress was induced by the two sizes of Fe_2O_3 particles. The activities of GSH-Px, Cu,Zn-SOD, and cNOS significantly elevated and the total GSH and GSH/GSSG ratio significantly decreased in the olfactory bulb and hippocampus after the nano- and submicron-sized Fe_2O_3 particle treatment (p ...

2009-01-01

379

Possible Computer Vision Systems and Automated or Computer-Aided ...  

Science.gov (United States)

Jun 16, 2011 ... The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or ...

381

Synthesis and photoluminescence properties of continuous freestanding SiC(Al) films derived from aluminum-containing polycarbosilane  

International Nuclear Information System (INIS)

Continuous freestanding SiC(Al) films were fabricated by melt spinning the aluminum-containing polycarbosilane (A-PCS) precursor. The results showed that the films contained #beta#-SiC crystals, #alpha#-SiC nano-crystals, C clusters and small amount of Al_4O_4C and Al_4SiC_4. The Al atoms in the films played important roles as both sintering aids and grain growth inhibitor. The PL spectrum showed a wide luminescence band from 320 nm to 440 nm, and the origin of PL centered at 385 nm might be related to the #alpha#-SiC nano-crystals using quantum size effects. The obtained films are expected to have important applications in MEMS for the environment of high temperature and optoelectronic devices.

2010-10-01

382

Multi walled carbon nanotubes/epilson polylysine nanocomposite with enhanced antibacterial activity  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aims: To develop a new nano composite of multi walled carbon nanotubes (MWNTs) with enhanced antimicrobial activity. Methods and Results: A novel antimicrobial nanocomposite [MWNT epilson polylysine (MEPs)] was synthesized via covalent attachment of epilson polylysine on MWNTs with hexamethylene diisocyanate (HDI) as the coupling agent. UV visible spectra and Fourier transform infrared spectra (FT IR) investigations indicate that MEPs is stable, with epilson polylysine leaching effectively eliminated. When compared to MWNTs, the new nano composite MEPs exhibits enhanced antimicrobial activities. In 20 mg l 1 suspensions, significant increases of 72 1, 64 5 and 69% against Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus can be observed. The deposited film of MEPs...

2011-01-01

383

Molecular dynamics simulation of effect of indenter shape on nanoscratch of Ni  

British Library Electronic Table of Contents (United Kingdom)

Thin films of Ni and Ni alloy have been widely used in microelectromechanical systems (MEMS) and magnetic storage systems. As the dimensions of components in these systems decrease to the micro-scale, even the nano-scale, the interfacial phenomena significantly differ to the counterparts on the macro-scale. A better understanding of micro-/nano-tribology will benefit the fabrication of the small components. In this manuscript parallel molecular dynamics (MD) simulations have been conducted to investigate the nanoscratch behavior of nickel. The simulations are performed for two cases with different indenter shapes. Case I has a sharp indenter, while the indenter in Case II is blunt. It has been found that the indenter shape significantly influences the nanoscratch deformation. The sharp ind...

2009-01-01

384

Irradiation induced dislocation loop and its influence on the hardening behavior of Fe-Cr alloys by an Fe ion irradiation  

International Nuclear Information System (INIS)

Nano indentation analysis and transmission electron microscopy observation were performed to investigate a microstructural evolution and its influence on the hardening behavior in Fe-Cr alloys after an irradiation with 8 MeV Fe4+ ions at room temperature. Nano indentation analysis shows that an irradiation induced hardening is generated more considerably in the Fe-15Cr alloy than in the Fe-5Cr alloy by the ion irradiation. TEM observation reveals a significant population of the a0 dislocation loops in the Fe-15Cr alloy and an agglomeration of the 1/2a0 dislocation loops in the Fe-5Cr alloy. The results indicate that the a0 dislocation loops will act as stronger obstacles to a dislocation motion than 1/2a0 dislocation loops.

2008-11-01

385

Investigation of the structure of nano-porous carbon obtained from polycrystal carbides by means of small-angle X-ray diffraction  

International Nuclear Information System (INIS)

The structure of nano-porous carbon, obtained by means of chlorination of carbide compounds with various crystal structure (SiC, TiC, Mo_2C) is studied through the method of small-angle diffraction. The angular dependences of the scattering intensity obtained are interpreted as the result of scattering from the nanoparticles of different size. The functions of the scattering particles distribution by the m(R_g) inertia radii are determined. It is shown that in spite of the source carbide, the highest fraction of the volume in the porous carbon constitute the particles with R_g #approx# 5 A. The nanoparticles in the samples obtained from SiC, wherein the average value of the R_g"a"v < 6 A, are most uniform by size. The nanoparticles in the porous carbon, obtained from Mo_2C, are on the average by two times larger

1999-08-01

386

Influence of RF power on the electrical and mechanical properties of nano-structured carbon nitride thin films deposited by RF magnetron sputtering  

International Nuclear Information System (INIS)

Nano structured carbon nitride thin films were deposited at different RF powers in the range of 50 W to 225 W and constant gas ratio of (argon: nitrogen) Ar:N_2 by RF magnetron sputtering. The atomic percentage of Nitrogen: Carbon (N/C) content and impedance of the films increased from 14.36% to 22.31% and 9 x 10"-"1 #OMEGA# to 7 x 10"5 #OMEGA# respectively with increase in RF power. The hardness of the deposited films increased from 3.12 GPa to 13.12 GPa. The increase in sp"3 hybridized C-N sites and decrease of grain size with increase in RF power is responsible for such variation of observed mechanical and electrical properties.

2010-10-01

387

Evaluation of the evaporation behavior of Pd, Mo, Te, and Sb in simulated low level radioactive liquid waste  

International Nuclear Information System (INIS)

To sophisticate the nuclear fuel recycling processes, the transfer percentages for Pd, Mo, Te, and Sb should be determined. Each element solution containing NaNO_3 or HNO_3 was fed consistently into the thin film evaporator regulated in vac and at 50 deg C. The analyte percentages in the inside of the lid, in the condenser, and in the distillate were 10"-"1%/m"2, 10"-"3%/m"2, and 10"-"3% (DF = 10"5), respectively. The Mo percentage in the condenser was lower by a factor of 10 than those of other elements investigated. The NO_3"- percentages were nearly constant despite increasing HNO_3 concentrations, however, the ratios decreased with increasing NaNO_3 concentrations. (author)

2003-02-01

388

Enhancement of bioleaching of a spent Ni/Mo hydroprocessing catalyst by Penicillium simplicissimum  

British Library Electronic Table of Contents (United Kingdom)

Statistically based experimental designs were applied to screen and optimize the bioleaching of spent hydrocracking catalyst by Penicillium simplicissimum. Eleven factors were examined for their significance on bioleaching using a Plackett-Burman factorial design. Four significant variables (pulp density, sucrose, NaNO"3, and yeast extract concentrations) were selected for the optimization studies. The combined effect of these variables on metal bioleaching was studied using a central composite design (CCD). Second-order polynomials were established to identify the relationship between the recovery percent of the metals and the four significant variables. The optimal values of the variables for maximum metals bioleaching were as follows: pulp density (4.0%, w/v), sucrose (90g/L), NaNO"3 (2...

2011-01-01

389

Direct nano ESI time-of-flight mass spectrometric investigations on lanthanide BTP complexes in the extraction-relevant diluent 1-octanol  

Energy Technology Data Exchange (ETDEWEB)

The present work focuses on investigations of a highly selective ligand for Am(III)/Ln(III) separation: bis-triazinyl-pyridine (BTP). By means of nano-electro-spray mass spectrometry, complex formation of BTP with selected elements of the lanthanide series is investigated. We show that the diluent drastically influences complex speciation. Measurements obtained in the extraction-relevant diluent 1-octanol show the occurrence of Ln(BTP){sub i} (i 1-3) species in different relative abundances, depending on the lanthanide used. Here, the relative abundances of the Ln(BTP){sub 3} complexes correlate with the distribution ratios for extraction to the organic phase of the respective lanthanide. (authors)

2009-12-15

390

Direct electrochemistry of catalase at amine-functionalized graphene/gold nanoparticles composite film for hydrogen peroxide sensor  

British Library Electronic Table of Contents (United Kingdom)

Direct electrochemistry and electrocatalysis of catalase (Cat) was studied based on a nano-composite film consisting of amine functionalized graphene and gold nanoparticles (AuNPs) modified glassy carbon electrode. Graphene was synthesized chemically by Hummers and Offeman method and then was functionalized with amino groups via chemical modification of carboxyl groups introduced on the graphene surface. The nano-composite film showed an obvious promotion of the direct electron transfer between Cat and the underlying electrode, which attributed to the synergistic effect of graphene-NH2 and AuNPs. The resultant bioelectrode retained its biocatalytic activity and offered fast and sensitive H2O2 quantification. Under the optimized experimental conditions, hydrogen peroxide was detected in the...

2011-01-01

391

Characterization of Y2BaCuO5 nanoparticles synthesized by nano-emulsion method  

British Library Electronic Table of Contents (United Kingdom)

Nanoscale yttrium?barium?copper oxide (Y2BaCuO5, Y211) particles were synthesized using the emulsion method and the solution method. The basic water-in-oil (w/o) emulsion system consisted of n-octane (continuous oil phase), cetyltrimethylammonium bromide (cationic surfactant), butanol (cosurfactant) and water. The composition of the emulsion system was varied and characterized by measuring the conductivity of the solutions and droplet size. The droplet size of emulsion was determined by using the dynamic light scattering method. The water content, cosurfactant content, and surfactant/n-octane ratio affected the droplet size which was in the range of 3?8?nm, and hence the w/o emulsion system was referred to as a nano-emulsion system. A model was used to verify the droplet size. The influenc...

2007-01-01

392

Amperometric biosensor for hydrogen peroxide based on horseradish peroxidase onto gold nanowires and TiO2 nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

An electrochemical biosensor for determination of hydrogen peroxide (H2O2) was fabricated, based on the electrostatic immobilization of horseradish peroxidase (HRP) with one-dimensional gold nanowires (Au NWs) and TiO2 nanoparticles (nano-TiO2) on a gold electrode. The nano-TiO2 can give a biocompatible microenvironment and compact film, and the Au NWs can provide fast electron transferring rate and greatly add the amount of HRP molecules immobilized on the electrode surface. Au NWs were characterized by ultraviolet?visible spectra and transmission electron microscope. The electrode modification process was probed by cyclic voltammetry and electrochemical impedance spectroscopy. Chronoamperometry was used to study the electrochemical performance of the resulting biosensor. Under optimal co...

2011-01-01

393

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub ...

2000-05-01

394

Selection of dimensions of scintillation detectors and of the correction energy with the use of the dual energy method in computerized tomography  

Science.gov (United States)

The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.

1986-05-01

395

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

396

Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques  

International Nuclear Information System (INIS)

In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

2010-06-01

397

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

398

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can ...

1996-10-01

399

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single photon emission ...

2003-12-01

400

Computer based training cost-benefit model  

Energy Technology Data Exchange (ETDEWEB)

The costs of establishing a computer-based training program for FFTF reactor operators are analyzed.

1984-01-01

401

Study of structural, thermodynamical and dynamical properties of molecular liquids confined in nano-porous materials; Etude des proprietes structurales, thermodynamiques et dynamiques de liquides moleculaires confines dans des materiaux nanoporeux modeles  

Energy Technology Data Exchange (ETDEWEB)

When liquids are confined in nano-scopic dimensions, their properties differ from the corresponding bulk liquid, due to their reduced dimensionality and surface effects. Phase transition temperatures and pressures are often shifted from the bulk values and new phases can appear due to the strong interactions of the molecules with the confining walls. We have studied the structural and dynamical properties of aromatic liquids such as benzene, toluene, and ortho-terphenyl confined in nano-porous materials, MCM-41 and SBA-15, synthesized and characterized in our laboratory. A non-trivial dependence of the glass transition temperature, T{sub g}, on the pore size and surface treatment of nano-porous materials is confirmed and interpreted as resulting from a competition between the fluid-wall and fluid-fluid intermolecular interactions. An increase of T{sub g} is observed for small pore sizes and attractive surface while T{sub g} ...

2006-11-15

402

Pulmonary response after exposure to inhaled nickel hydroxide nanoparticles: short and long-term studies in mice  

UK PubMed Central (United Kingdom)

Short and long-term pulmonary response to inhaled nickel hydroxide nanoparticles (nano-Ni(OH)2, CMD = 40 nm) in C57BL/6 mice was assessed using a whole body exposure system. For short-term...Full Text Available

2010-03-01

403

Piezoelectrics based on a hybrid of piezoelectric matrix nano- and microcomposites  

British Library Electronic Table of Contents (United Kingdom)

The physics and technology of a new class of efficient composite piezoelectrics are described. This material combines nanostructured and micropiezoelectric matrix composites. They consist of a polymer matrix, an insulating nanodimensional phase, and a microdimensional piezoelectric phase. It is shown that the nanostructuring of the near-surface region of polymer-PZT piezoelectric composites greatly improves their piezoelectric, mechanical, and electromechanical characteristics. A plausible mechanism underlying this effect is suggested.

2011-01-01

404

Phase-plate electron microscopy: a novel imaging tool to reveal close-to-life nano-structures  

UK PubMed Central (United Kingdom)

After slow progress in the efforts to develop phase plates for electron microscopes, functional phase plate using thin carbon film has been reported recently. It permits collecting high-contrast images...Full Text Available

2009-03-01

405

Optical chemical sensors for atmospheric pollutants based on nano porous materials: application to the formaldehyde and the other carbonyl compounds; Capteurs chimiques a transduction optique de polluants atmospheriques a base de materiaux nanoporeux: application au formaldehyde et autres composes carbonyles  

Energy Technology Data Exchange (ETDEWEB)

Formaldehyde, a well-identified indoor pollutant, was recently classified as carcinogenic. New regulations for the air quality are expected and therefore there is a need for low-cost sensors, sensitive and selective with a fast response time for the detection of formaldehyde at ppb level. In the present work, we had developed a chemical sensor based on nano-porous matrices doped with Fluoral-P and optical methods of detection. The nano-porous matrices, elaborated via the Sol-Gel process, display nano-pores whose cavity is tailored for the trapping of the targeted pollutant. They provide a first selectivity with the discrimination of the pollutants by their size. A second selectivity is obtained with a molecular probe, Fluoral-P, which reacts specifically with formaldehyde leading to the 3,5- di-acetyl-1,4-dihydro-lutidine (DDL). The kinetics of formation of DDL was studied as function of many parameters such as the ...

2006-12-15

406

Ion-Track Membranes and Their Use in Biological and Medical Applications  

International Nuclear Information System (INIS)

This report is a brief review of biological and medical applications of ion-track membranes. The review aims at informing nuclear physicists about alternative (i.e. non-fundamental-science) use of heavy ion accelerators such as production of micro- and nano-porous materials. The ion-track membranes produced this way are employed in life sciences and numerous technological applications. The author focuses on recent results from the Flerov laboratory in co-operation with other scientific institutions and industrial partners.

2007-05-22

407

Identification of physochemical factors controlling the capacity of nano-particles to penetrate cells of the respiratory epithelium  

Environmental Research Database

Objectives1) To establish a protocol for transfection of immortalised type I cells with SiRNA and its effect on cell viability; 2) To optimise silencing of genes involved in endocystosis using SiRNA and confirm successful transfection with western blotting; 3) To investigate the effect of gene silencing on uptake of flourescently-labelled latex nanoparticles.DescriptionTo investigate the mechanisms of particle uptake.

2009-01-31

408

Hydrogen in nano-sized metals  

Energy Technology Data Exchange (ETDEWEB)

Systems with small sizes show significant changes compared to the bulk system. These changes are of major interest regarding the size reduction of technological applications. The hydrogen-metal system can be used as a model alloy to study small size features: shifted phase boundaries and sloped isotherms are found and, also, new materials structures. Most features can be attributed to surface- and interface contributions as well as to mechanical stress. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

2004-02-01

409

Defra Studentship: Biodegradable starch nano-composites for thermoformable film packaging for food products  

Environmental Research Database

DescriptionThe objective is to exploit the use of wheat as an industrial raw material and understand the effect of material variation in wheat starch and flour on final material properties for food packaging applications. The project will focus on property enhancement in terms of stiffness, strength, toughness, moisture barrier resistance, transparency, ageing resistance, microbial stability and biodegradability of starch-based packaging materials made by sheet extrusion and thermoforming processes, in ord [continued...

2008-01-31

410

A magneto-electric quantum wheel  

CERN Document Server

Here we show that self-propulsion in quantum vacuum may be achieved by rotating or aggregating magneto-electric nano-particles. The back-action follows from changes in momentum of electro-magnetic zero-point fluctuations, generated in magneto-electric materials. This effect may provide new tools for investigation of the quantum nature of our world. It might also serve in the future as a "quantum wheel" to correct satellite orientation in space.

2009-01-01

411

Quantum computing for physics research  

Energy Technology Data Exchange (ETDEWEB)

Quantum computers hold great promises for the future of computation. In this paper, this new kind of computing device is presented, together with a short survey of the status of research in this field. The principal algorithms are introduced, with an emphasis on the applications of quantum computing to physics. Experimental implementations are also briefly discussed.

2006-04-01

412

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and Computerized ...

1997-01-01

413

What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?  

International Nuclear Information System (INIS)

Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second phase) used the least contrast media and had the least frequency of streak artifacts, but there were no significant differences in coronary artery attenuation, image ...

2010-08-01

414

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...

2003-05-01

415

Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience  

International Nuclear Information System (INIS)

Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of ...

2005-03-01

416

Retrospective Monte Carlo dose calculations with limited beam weight information  

International Nuclear Information System (INIS)

An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography densities. Validation ...

2007-01-01

417

Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies; Valutazione quantitativa dell`enfisema polmonare mediante Tomografia Computerizzata. Confronto tra il punteggio visivo con alta risoluzione nell`inspirazione, maschera della densita` automatica con Tomografia Computerizzata spirale nell`espirazione ed esami funzionali respiratori  

Energy Technology Data Exchange (ETDEWEB)

CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas ...

1997-04-01

418

Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies  

International Nuclear Information System (INIS)

CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas ...

1997-01-01

419

Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography  

Energy Technology Data Exchange (ETDEWEB)

A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated with their height (H), the different phases (xA + (1 - x)V) and the ratio [xA + (1 ...

2004-12-01

420

Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures  

International Nuclear Information System (INIS)

The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in 38%. Morphology was unchanged in 63% of ...

1999-12-01

421

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma; Integrazione delle immagini della Tomografia Computerizzata con emissione di fotone singolo in un sistema commerciale per l'elaborazione dei piani di radioterapia. Applicazione all'irradiazione conformazionale del carcinoma polmonare  

Energy Technology Data Exchange (ETDEWEB)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. [Italian] L'integrazione delle immagini diagnostiche aventi diverso contenuto informativo anatomico-funzionale puo' essere utilizzata nella radioterapia per migliorare le procedure diagnostiche e ottimizzare la geometria dell'irraggiamento. I sistemi per l'elaborazione di piani di radioterapia oggi in uso sono direttamente interfacciati con gli apparecchi di Tomografia Computerizzata (TC) e ...

1999-04-01

422

Immunoscintigraphy with anti-225.28S for ocular melanoma - a comparison with histology and immunohistochemistry  

Energy Technology Data Exchange (ETDEWEB)

Aim: The purpose of this prospective study was to evaluate the value of immunoscintigraphy (ISG) with anti-225.28S in clinically suspected ocular melanoma. Methods: For this purpose standardized ISG was performed in 36 patients using both planar acquisition and emission computed tomography (ECT). Ocular melanoma was present in 31 patients. In 21 patients therapy was enucleation of the eye. These specimens were evaluated by histology and immunohistochemistry in 11 of 21 patients. Results: Regarding the clinical diagnosis, ISG was positive only in 15 of 31 patients with ocular melanoma, regarding histology in 11 of 21 and regarding immunohistochemistry in 5 of 6 patients with a positive immunoreaction. 5 patients showed no immunoreactivity, their ISG was negative. Conclusion: Thus a good correlation between ISG and immunohistochemistry was observed. However ISG using the cutaneous melanoma antibody 225.28S cannot be recommended for the diagnostic ...

1997-03-01

423

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

Energy Technology Data Exchange (ETDEWEB)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow ...

1995-07-01

424

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

International Nuclear Information System (INIS)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow regime, void ...

1346-01-01

425

Computed tomography of the mediastinal lesion  

Energy Technology Data Exchange (ETDEWEB)

Authors retrospectively analyzed the CT findings of mediastinal lesions in surgically or clinically confirmed 37 cases at Kosin Medical College during recent 4 years from September 1979 to August 1983. 1. Among 37 caes, malignant lymphoma were 7 cases, thymoma and vascular lesion or anomaly were 5 cases respectively, benign teratoma and tuberculous mediastinal lymphadenitis and neurogenic tumor were 4 cases respectively, pericardial cyst were 2 cases, bronchogenic cyst, non-specific cyst, pancreatic pseudocyst, mesothelioma, Bochdalek hernia was 1 case respectively. 2. The sex ratio between male and female was about 1 : 1 and the majority of the patients with malignant lymphoma and teratoma was under 20 years old. 3. CT findings of the each mediastinal lesion. 1) Primary mediastinal malignant lymphoma. (1) A large, matted, continuous and midline-crossing mass was observed in the superior and the anterior mediastinums in all cases. (2) In 3 cases, irregular lower densities were seen in ...

1984-09-15

426

CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia  

International Nuclear Information System (INIS)

Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study ...

2010-01-01

427

CT in the study of thoracic-pulmonary complications after liver transplantation  

International Nuclear Information System (INIS)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the reasons were unknown; 133/152 (87.5%) ...

2000-12-01

428

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized ...

2006-04-15

429

The Prevalence of Concha Bullosa and Nasal Septal Deviation and Their Relationship to Maxillary Sinusitis by Volumetric Tomography  

UK PubMed Central (United Kingdom)

The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available

2010-01-01

430

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

431

Relation between frequency of seismic wave and resolution of tomography; Danseiha tomography kaiseki ni okeru shuhasu to bunkaino no kankei  

Energy Technology Data Exchange (ETDEWEB)

With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring ...

1997-05-27

432

Fourier-Domain Optical Coherence Tomography and Adaptive Optics Reveal Nerve Fiber Layer Loss and Photoreceptor Changes in a Patient With Optic Nerve Drusen  

UK PubMed Central (United Kingdom)

BackgroundNew technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic...Full Text Available

2008-06-01

433

Effects of Age on Optical Coherence Tomography Measurements of Healthy Retinal Nerve Fiber Layer, Macula and Optic Nerve Head  

UK PubMed Central (United Kingdom)

PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available

2009-06-01

434

CLINICAL VALUE, NORMATIVE RETINAL SENSITIVITY VALUES, AND INTRASESSION REPEATABILITY USING A COMBINED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY/SCANNING LASER OPHTHALMOSCOPE MICROPERIMETER  

UK PubMed Central (United Kingdom)

PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available

2011-02-01

435

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

436

Altered myocardial substrate metabolism is associated with myocardial dysfunction in early diabetic cardiomyopathy in rats: studies using positron emission tomography  

UK PubMed Central (United Kingdom)

BackgroundIn vitro data suggest that changes in myocardial substrate metabolism may contribute to impaired myocardial function in diabetic cardiomyopathy (DCM)....Full Text Available

437

Quantum computing  

UK PubMed Central (United Kingdom)

Quantum computing is a quickly growing research field. This article introduces the basic concepts of quantum computing, recent developments in quantum searching, and decoherence in a possible quantum...Full Text Available

2001-10-09

438

Interactive computer programs in sequence data analysis.  

UK PubMed Central (United Kingdom)

We present interactive computer programs for the analysis of nucleic acid sequences. In order to handle these programs, minimum computer experience is sufficient. The nucleotide sequence of the human...Full Text Available

1982-01-11

439

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

440

Computer Lab  

USGS Gallery

USGS geologists Peter Triezenberg and William Danforth sit with WHOI/LDEO Computer Technician Tom Bolmer in the Healy computer lab. This was during a scientific expedition to map the Arctic seafloor....

2009-01-28

441

Spiral CT with three-dimensional and multiplanar reconstruction in the diagnosis of anterior chest wall joint and bone disorders  

Energy Technology Data Exchange (ETDEWEB)

Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).

1994-09-01

442

Consistency of ocular coherence tomography fast macular thickness mapping in diabetic diffuse macular edema  

Energy Technology Data Exchange (ETDEWEB)

Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map ...

2007-07-01

445

Quantum computing and the chaotic amplifier  

Energy Technology Data Exchange (ETDEWEB)

A new model for computations is considered which combines the quantum computer with the chaotic dynamics amplifier, based on the logistic map. We discuss the satisfiability problem and argue that the problem can, in principle, be solved in polynomial time if one uses the new model for computations.

2003-12-01

450

Computational approaches to discovering semantics in molecular biology  

Energy Technology Data Exchange (ETDEWEB)

One of the central questions of molecular biology is the discovery of the semantics of DNA. This discovery relies in a critical way on a variety of expensive computations. In order to solve these computations, both parallel computers and special-purpose hardware play a major role.

1989-07-01

453

Synthesis of nano-size Ca-#alpha# SiAlON Powders by carbothermal reduction-nitridation  

International Nuclear Information System (INIS)

Carbothermal reduction-nitridation (CRN) of SiO_2 is an attractive method for manufacturing Si_3N_4 powders with controlled grain morphology. Moreover, #beta#-sialon powders could also be synthesized from either pure powder mixtures or some inexpensive raw minerals by CRN. The resultant powders have shown some advantages, especially in manufacturing sialon products at low cost. However, there have been only a few works on preparing #alpha#-sialon powders. In this work, Ca-#alpha# sialon powder was synthesized by CRN of a SiO_2-Al_2O_3 and CaCO_3 powder mixture An unusual morphology of hollow balls of 200 to 500nm with many nano size #alpha#-sialon particles of 10 to 30nm was identified from the resultant Ca-#alpha# sialon powders. This has never been previously reported for sialon ceramics. It was consequently confirmed that the morphologies of the products were clearly related to the intermediate products appearing during CRN reaction. Copyright (2000) The ...

454

Synthesis of nano Sb-encapsulated pyrolytic polyacrylonitrile composite for anode material in lithium secondary batteries  

Energy Technology Data Exchange (ETDEWEB)

A novel process was proposed to synthesize nano Sb-encapsulated pyrolytic polyacrylonitrile composite for anode material in lithium secondary batteries. The preparation started with the dissolution of SbCl{sub 3} and polyacrylonitrile (PAN) in dimethylformamide (DMF) solution, followed by the addition of KBH{sub 4} to reduce Sb{sup 3+} in the solution. The Sb composite was obtained by pyrolysis of the Sb/PAN mixture that precipitated out when the DMF solution was added by plentiful water. The TEM analysis showed that about 100-200 nm Sb particles were embedded by the pyrolyzed PAN, which provided a conductive matrix to relieve the morphological change of Sb during electrochemical cycling. As-prepared composite presented good cycleability for lithium storage. The proposed process paves an effective way to prepare high performance alloy based composite anode materials for high performance lithium-ion batteries. (author)

2007-03-01

455

Single-Electrode Transient Behavior for Electric Double Layer Capacitor Composed of Nano-Porous Carbon Electrode; Kasseitan denki 2jyuso kyapasita no tankyoku jyuhoden katei ni taisuru sokudoronteki kento  

Energy Technology Data Exchange (ETDEWEB)

Single-electrode transient behavior was measured mainly during the discharging process for a model cell of electric double layer capacitor with nano-porous carbon electrodes and reference electrode. Apparent conductivity in the cell, which we call `effective conductivity,` is determined with approximation of current in transient behavior to a one-dimensional electrophoretic model. A comparison of effective conductivity with conductivity of bulk solution suggests an interesting mechanism of transfer of electrolyte ions. The difference in transient behavior between various electrolyte ions was not conspicuous in spite of distinctive differences in conductivity of each bulk solution. The large pore diameter of the carbon electrode results in rapid transient behavior and such an electrode should be suitable for rapid charge and discharge. The effect of origin of carbon electrode is found to be significant to bring considerable differences in discharge rate. However, ...

1997-07-10

456

Single-Electrode Capacitance and Charged State in Interfacial Region within Nano-Porous Carbon Electrode for Electric Double Layer Capacitor; Kasseitan denki 2jyuso kyapasita no tankyoku seiden yoryo to koeki kaimen chikuden jyotai  

Energy Technology Data Exchange (ETDEWEB)

The single-electrode capacitance of a nano-porous carbon electrode used as an electric double layer capacitor was measured. The charged state of the electrolyte ion was discussed from the results. Single-electrode capacitance was not proportional to the specific surface area of the electrode. This implies that the whole surface of the electrode is not effective for the formation of an electric double layer. It is considered that edge orientation of the carbon structure would give a dominant contribution to capacitance. For measurements with aqueous solutions of various electrolytes, capacitance was about the same value for each salt compound. For aqueous acid solution, on the other hand, capacitance was twice to three times as large as that for salt compounds. This difference, however, became negligibly small if the concentration of electrolyte solution was lowered. Taking account of the hydrated ionic radius of each ion, it was considered that ions in salt ...

1997-07-10

457

Photocatalytic self-cleaning properties of cellulosic fibers modified by nano-sized zinc oxide  

International Nuclear Information System (INIS)

Nano-sized zinc oxide was synthesized and deposited onto cellulosic fibers using the sol-gel process at ambient temperature. The prepared materials were characterized using several techniques including scanning electron microscopy, transmission electron microscopy, diffuse reflectance spectroscopy, X-ray diffraction and thermogravimetric analysis. X-ray diffraction studies of the ZnO-coated fiber indicate formation of the hexagonal crystal phase which was satisfactory crystallized on the fiber surface. The electron micrographs show formation of zinc oxide nanoparticles within 10-15 nm in size which have been homogeneously dispersed on the fiber surface. The prepared materials show significant photocatalytic self-cleaning activity, which was monitored by diffuse reflectance spectroscopy. The photoactivity was studied upon measuring the photodegradation of methylene blue and eosin yellowish under UV-Vis irradiation. The photocatalytic activity of the treated fabrics ...

2011-03-31

458

Organic against inorganic electrodes grown onto polymer substrates for flexible organic electronics applications  

Energy Technology Data Exchange (ETDEWEB)

One of the most challenging topics in the area of organic electronic devices is the growth of transparent electrodes onto flexible polymeric substrates that will be characterized by enhanced conductivity in combination with high optical transparency. An essential aspect for these materials is their synthesis and/or microstructure which define the transparency, the stability and the interfacial chemistry which in turn determine the performance and stability of the organic electronic devices, such as organic light emitting diodes, organic photovoltaics, etc. In this work, we will discuss the latest advances in the growth of organic (e.g. PEDOT:PSS) and inorganic (e.g. zinc oxide-ZnO, indium tin oxide-ITO) conductive materials and their deposition onto flexible polymeric substrates. We will compare the optical, structural, nano-mechanical and nano-topographical properties of the inorganic and organic materials and we investigate the effect of ...

2009-12-15

459

Optical and structural properties of Ge films from ion-assisted deposition  

International Nuclear Information System (INIS)

The optical properties and microstructure of germanium (Ge) films, prepared by ion-assisted deposition (IAD) process, were investigated. The Ge films were deposited on sapphire and silicon substrates, with and without simultaneous Ar+ bombardment. Higher index films, with a refractive index 7.7% larger than that of the single crystalline Ge wafer, were obtained with the IAD process. The density of the IAD film could be 1.5% greater than that of the e-beam film. The results of the heat treatment indicated that the optical and structural properties of the IAD films were more stable. Ge nano-crystallites could be observed under high ion power density, which induced a crystalline structure in the Ge thin films. The average size of the nano-crystallites, as determined from both the X-ray diffraction data and the transmission electron microscopy images, showed that no systematic change had occurred. The results presented in this work suggest that the ...

2008-11-28

460

Microstructural and mechanical characterization of high energy ball milled and sintered WC-10wt%Co-xTaC nano powders  

British Library Electronic Table of Contents (United Kingdom)

Ultra fine tungsten carbide and cobalt powders were milled by high energy planetary ball mill at different ball to powder weight ratios (BPR) to produce particles of WC-10wt%Co hard metal in nanometer scale size. Microstructural characterizations by TEM show that the particle size of tungsten carbide was achieved to 32nm after milling at 15 BPR during 10h. In order to reduce the WC grain growth during the sintering process, tantalum carbide was added to the hard metal as a WC grain growth inhibitor. The nano hard metal powders were compacted at 200MPa pressure and sintered at 1370-1450degreeC temperatures in a high purity hydrogen atmosphere. The results show that the addition of 0.6wt% of TaC improves the hardness and fracture toughness from 1493 HV30 and 11.8MPam (for TaC free sample) to...

2009-01-01

461

Hydrogen-related surface modifications of 20 nm thin straight-sided niobium nano-wires and niobium meander-films  

Energy Technology Data Exchange (ETDEWEB)

Nano-wire arrays of Niobium were produced by small angle sputtering on facetted sapphire, using the self shadowing effect of the facets. A wire width of about 80 nm was adjusted, the mean (maximum) wire height was about 20 nm (30 nm), the length can be in the cm range. Meander-film morphologies of 20 nm mean (26 nm maximum) thickness were produced by conventional sputtering onto smooth sapphire substrates at elevated temperatures. The morphology of the wires was investigated with atomic force microscopy (AFM), using contact mode. Meander-films were studied by scanning tunnelling microscopy (STM). Hydrogen loading was performed by instantaneously increasing the hydrogen gas pressure above the solubility limit. Thus, an elongated hydride could be monitored in an about 30 nm thick wire. STM studies on meander-films show the presence of cylindrical hydrides. Local out-of-plane and in-plane expansion can be explained by the formation of hydrides, being coherent with the ...

2007-10-31

462

Hybridization and Modification of the Ni/C{sub 60} Composites  

Science.gov (United States)

Hybridization and thermal evolution of the Ni+C{sub 60} composites, deposited on Si(001) at room temperature, were studied using Scanning Electron Microscopy, {mu}-Raman spectroscopy and Rutherford Backscattering. As-deposited, the hybrid films exhibited a granular nano-structure with Ni nano-particles encapsulated in C{sub 60} polymerized rinds. The Ni and C (C{sub 60}) distributions in a top layer were found homogeneous with a stable Ni/C (C{sub 60}) ratio; in the larger depth the distributions were inhomogeneous and their ratio dramatically varied. At elevated temperatures, all structural parameters were changed. In the subsurface layer Ni- and C (C{sub 60})-rich zones were formed (due to the induced phase separation), C{sub 60}-molecules decayed and their fragments were transformed into amorphous carbon (a-C). The free volume distribution of the stressed hybrid matter was analyzed by the Hg marker that (in a form of vapors) in-diffused in ...

2009-03-10

463

Fully transparent thin-film transistor devices based on SnO2 nanowires.  

Science.gov (United States)

We report on studies of field-effect transistor (FET) and transparent thin-film transistor (TFT) devices based on lightly Ta-doped SnO2 nano-wires. The nanowire-based devices exhibit uniform characteristics with average field-effect mobilities exceeding 100 cm2/V x s. Prototype nano-wire-based TFT (NW-TFT) devices on glass substrates showed excellent optical transparency and transistor performance in terms of transconductance, bias voltage range, and on/off ratio. High on-currents and field-effect mobilities were obtained from the NW-TFT devices even at low nanowire coverage. The SnO2 nanowire-based TFT approach offers a number of desirable properties such as low growth cost, high electron mobility, and optical transparency and low operation voltage, and may lead to large-scale applications of transparent electronics on diverse substrates. PMID:17595151

2007-06-27

464

Focused ion beam etching of nanometer-size GaN/AlGaN device structures and their optical characterization by micro-photoluminescence/Raman mapping  

Energy Technology Data Exchange (ETDEWEB)

The authors report on the nano-fabrication of GaN/AlGaN device structures using focused ion beam (FIB) etching, illustrated on a GaN/AlGaN heterostructure field effect transistor (HFET). Pillars as small as 20nm to 300nm in diameter were fabricated from the GaN/AlGaN HFET. Micro-photoluminescence and UV micro-Raman maps were recorded from the FIB-etched pattern to assess its material quality. Photoluminescence was detected from 300nm-size GaN/AlGaN HFET pillars, i.e., from the AlGaN as well as the GaN layers in the device structure, despite the induced etch damage. Properties of the GaN and the AlGaN layers in the FIB-etched areas were mapped using UV Micro-Raman spectroscopy. Damage introduced by FIB-etching was assessed. The fabricated nanometer-size GaN/AlGaN structures were found to be of good quality. The results demonstrate the potential of FIB-etching for the nano-fabrication of III-V nitride devices.

2000-07-01

465

Facile synthesis of additive-assisted nano goethite powder and its application for fluoride remediation  

Energy Technology Data Exchange (ETDEWEB)

The present article describes a novel synthesis route for nano-sized goethite ({alpha}-FeOOH) using hydrazine sulphate as an additive. The X-ray diffraction (XRD) peaks of synthesized powder matched well with those of {alpha}-FeOOH. Transmission electron microscopy (TEM) showed the particles of irregular shape in the range of 1-10 nm. Batch adsorption experiments for fluoride uptake were performed to study the influence of various experimental parameters such as contact time (10 min to 7 h), initial fluoride concentration (10-150 mg L{sup -1}), pH (2-11.6) and the presence of competing anions. The time data fitted well to pseudo-second-order kinetic model. The fluoride removal passed through broad maxima in pH ranges of 6-8. High adsorption capacity of 59 mg g{sup -1} goethite was obtained. The isothermic data fitted well to Freundlich model. The presence of other ions namely chloride and sulphate adversely affected fluoride removal. Fluoride from contaminated ...

2010-02-15

466

Direct electrochemistry of catalase at amine-functionalized graphene/gold nanoparticles composite film for hydrogen peroxide sensor  

International Nuclear Information System (INIS)

Direct electrochemistry and electrocatalysis of catalase (Cat) was studied based on a nano-composite film consisting of amine functionalized graphene and gold nanoparticles (AuNPs) modified glassy carbon electrode. Graphene was synthesized chemically by Hummers and Offeman method and then was functionalized with amino groups via chemical modification of carboxyl groups introduced on the graphene surface. The nano-composite film showed an obvious promotion of the direct electron transfer between Cat and the underlying electrode, which attributed to the synergistic effect of graphene-NH2 and AuNPs. The resultant bioelectrode retained its biocatalytic activity and offered fast and sensitive H2O2 quantification. Under the optimized experimental conditions, hydrogen peroxide was detected in the concentration range from 0.3 to 600 ?M with a detection limit of 50 nM at S/N = 3. The biosensor exhibited some advantages, such as short time respond (2 s), ...

2011-02-28

467

Development of 40m SANS and Its Utilization Techniques  

Energy Technology Data Exchange (ETDEWEB)

Small angle neutron scattering (SANS) has been a very powerful tool to study nanoscale (1-100 nm) bulk structures in various materials such as polymer, self assembled materials, nano-porous materials, nano-magnetic materials, metal and ceramics. Understanding the importance of the SANS instrument, the 8m SANS instrument was installed at the CN beam port of HANARO in 2001. However, without having a cold neutron source, the beam intensity is fairly low and the Q-range is rather limited due to short instrument length. In July 1, 2003, therefore, the HANARO cold neutron research facility project was launched and a state of the art 40m SANS instrument was selected as top-priority instrument. The development of the 40m SANS instrument was completed as a joint project between Korea Advanced Institute of Science and Technology and the HANARO in 2010. Here, we report the specification of a state of art 40m SANS instrument at HANARO

2010-06-15

468

CUTTING PERFORMANCE AND WEAR MECHANISM OF Si3N4-BASED NANOCOMPOSITE CERAMIC CUTTING TOOL IN MACHINING OF CAST IRON  

British Library Electronic Table of Contents (United Kingdom)

A type of Si3N4-based nanocomposites ceramic cutting tool material was prepared by the addition of nano-scale Si3N4W whisker and nano-scale TiN particle. Cutting performance of the Si3N4/Si3N4W/TiN nanocomposite ceramic tool in machining of cast iron was investigated in comparison with a commercial sialon ceramic tool, and the tool wear mechanism was studied. The two types of cutting tools have similar cutting performance at relatively low cutting parameters, while Si3N4/Si3N4W/TiN nanocomposite tool exhibits a better wear resistance than sialon tool at the relatively high cutting parameters. The wear of sialon ceramic cutting tool is dominated by the plastic deformation, abrasive action, microcracking, pullout of grains and chemical action at the higher cutting parameters. The higher mech...

2011-01-01

469

Use of Computer Vision and Force Sensors for Tight ...  

Science.gov (United States)

... Accession Number : ADD811953. Title : Use of Computer Vision and Force Sensors for Tight Tolerance Assembly. Descriptive ...

1993-05-01

470

Rubin's Empirical Bayes Computations are Not Useful for Law ...  

Science.gov (United States)

... Accession Number : ADA100385. Title : Rubin's Empirical Bayes Computations are Not Useful for Law School Admissions - Comment,. ...

471

RAYMAN: A FORTRAN Computer Code for Tracing Rays ...  

Science.gov (United States)

... Descriptors : *COMPUTERIZED SIMULATION, *HUMAN BODY, *WOUND BALLISTICS, COMPUTER PROGRAMS, PROJECTILES, MATRICES ...

1977-11-01

472

Optical Phenomena in Computer Vision,  

Science.gov (United States)

... Accession Number : ADA152970. Title : Optical Phenomena in Computer Vision,. Corporate Author : ROCHESTER UNIV ...

1984-03-01

473

Issues in Computer Network Security.  

Science.gov (United States)

... Accession Number : ADA060007. Title : Issues in Computer Network Security. Descriptive Note : Technical rept.,. Corporate ...

1978-09-01

474

Depth Perception in Stereo Computer Vision.  

Science.gov (United States)

... Accession Number : ADA019663. Title : Depth Perception in Stereo Computer Vision. Descriptive Note : Technical rept.,. ...

1975-10-01

475

Computer and Network Security Information  

Science.gov (United States)

Computer And Network Security: Information For Everyone: This presentation was originally prepared as the 14th talk in a series known as "The Programmer's ...

476

Adaptive System and Method for Responding to Computer ...  

Science.gov (United States)

Page 1. Adaptive system and method for responding to computer network security attacks Abstract A dynamic network security ...

2002-07-11

477

A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber  

Science.gov (United States)

... In this paper research aimed at creating a computer vision system to power such an optimal edging and ... ...

478

Sub-wavelength localization of near-fields in coupled metallic spheres for single emitter polarization analysis  

CERN Document Server

We numerically demonstrate selective near-field localization determined by the polarization state of a single emitter coupled to plasmonic nano-cluster. Seven gold nanospheres are carefully arranged such that up to ten polarization states of the single emitter, including linear, circular, and elliptical polarizations, can be distinguished via the distinct field localization in four gaps. The ability to transform polarization state into field spatial localization may find application for single emitter polarization analysis.

2011-01-01

479

Study of the mechanism of electrochemical hydrogen storage in nano-porous carbons  

Energy Technology Data Exchange (ETDEWEB)

An efficient method of hydrogen storage in nano-porous carbons is its reversible sorption by electrochemical decomposition of a KOH water solution according to the following equation: C + xH{sub 2}O + xe{sup -} {yields} (CH{sub x}) + xOH{sup -} where (CH{sub x}) stands for the hydrogen inserted into the nano-porous carbon during charging and oxidized during discharging. Although various carbon materials have been investigated as hydrogen adsorbents, the information about the storage mechanism as well as the nature of the hydrogen/carbon interaction is still not sufficient. In order to extend the understanding of the process, carbon samples charged electrochemically were investigated by temperature programmed desorption (TPD). The nature of the hydrogen/carbon interaction was studied by electrochemical analysis at different temperatures. The TPD experiments consist of heating the samples from room temperature to 950 C and of quantitative ...

2005-07-01

480

Refractometry of organosilica microspheres  

CERN Document Server

The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard laboratory spectrometer. The second method relies on the measurable trapping potential of these beads in the focused light beam (laser tweezers). Polystyrene beads were used to test these methods, and the determined dispersion curves of refractive index values have been found accurate. The refractive index of organosilica beads has been determined to range from 1.60-1.51 over the wavelength range of 300-1100 nm.

2007-01-01

481

Plasma Enhanced Chemical Vapor Deposition (PECVD) Application And Atmospheric Pressure Plasma Characteristics  

International Nuclear Information System (INIS)

Atmospheric pressure plasma enhanced chemical vapour deposition system is built. The electrical and optical characteristics of the APPECVD system is given. The system is used to deposit conductive polymers and nano composites onto glass and metal surfaces. The morphological, optical, chemical and electrical characteristics of deposited surfaces are investigated using SEM, AFM four probe deposition purposes. The photovoltaic applications of plasma deposited polymers and nonconsumption are compared with deposited with electrochemical methods show different results. The electrical, chemical and morphological structures of the samples will be given.

2008-08-25

482

Nanocrystalline and policrystalline phases present in the protective metalloceramic coatings  

International Nuclear Information System (INIS)

New data about the structure of high-temperature resistant metalloceramic plasma sprayed coatings in micro and nano areas are presented. Application of the new instrumental methods: transmission electron microscopy combined with selected area electron diffraction mode is possible to obtain these data. The first layer in Ni based metallic bond coat shows nanocrystalline structure. External ceramic layer based on stabilised ZrO_2 is polycrystalline and contains both cubic and tetragonal crystalline phases. Local inhomogeneities in coatings phase composition are determined. (author)

2001-09-23

483

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

484

Domain wall pining in a jointed ferromagnetic nano-wire  

Energy Technology Data Exchange (ETDEWEB)

The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.

2004-05-01

485

Design of intelligent nucleobases and DNA HOMO mapping.  

Science.gov (United States)

We have designed a new nucleobase, benzodeazaadenine (BDA) that has a stronger charge transport ability than guanine and is not destroyed during charge transport process. By incorporating this new nucleobase into DNA, we demonstrated a protocol for real DNA nano-wire that is far superior to natural DNA. We also demonstrated that the selectivity for the interaction of Mn(II) ion with guanine N7 in G runs is a HOMO-controlled process, and as a consequence, the selectivity for G-metal ion interactions obtained by 15N-NMR studies would directly reflect the HOMO distribution of G-containing sequences in B-DNA. PMID:12903077

2002-01-01

486

Controllable growth and magnetic properties of nickel nanoclusters electrodeposited on the ZnO nanorod template  

International Nuclear Information System (INIS)

The ZnO nanorods were used as a template to fabricate nickel nanoclusters by electrodeposition. The ZnO nanorod arrays act as a nano-semiconductor electrode for depositing metallic and magnetic nickel nanoclusters. The growth sites of Ni nanoclusters could be controlled by adjusting the applied potential. Under -1.15 V the Ni nanoclusters could be grown on the tips of ZnO nanorods. On increasing the potential to be more negative the ZnO nanorods were covered by Ni nanoclusters. The magnetic properties of the electrodeposited Ni nanoclusters also evolved with the applied potentials.

2009-12-09

487

Coating of metallic membranes by pulsed laser deposition; Beschichtung von metallischen Membranen mittels Pulsed Laser Deposition  

Energy Technology Data Exchange (ETDEWEB)

There is increasing demand to functionalize meso- and nano-porous materials by coating and make the porous substrate biocompatible or environment friendly. However, coating on a meso-porous substrate poses great challenges, especially if the pore aspect ratio is high. In the current work the pulsed laser deposition (PLD) method is used for coating Ni{sub 3}Al-based meso-porous membranes with diamond-like carbon (DLC) layers of high thickness homogeneity and adhesion. (orig.)

2008-08-15

488

Applications of Cerius2, software of molecular simulation; Aplicaciones de Cerius2, software de simulacion molecular  

Energy Technology Data Exchange (ETDEWEB)

Most of the investigations have a theoretical sustenance based on molecular simulation. The area of application of molecular simulation is very wide, in the Materials Technology Department assigned to the Applied Sciences Management have been treated problems about metallic nano structures, glasses, interfaces, and molecules, to sustain and to explain some of the experimental results. Energy calculations are carried out to determine minimum energy structures, for later on to carry out calculations of some of their properties; as well as the images simulation of Electron microscopy and X-ray diffraction. (Author)

2007-07-01

489

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to ...

2006-06-15

490

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to ...

2006-06-01

491

Study of Pd-Sn/Al{sub 2}O{sub 3} catalysts prepared by an oxide colloidal route; Etude de catalyseurs Pd-Sn/Al{sub 2}O{sub 3} prepares par voie colloidale oxyde  

Energy Technology Data Exchange (ETDEWEB)

The oxide colloidal route, developed in the laboratory for mono-metallic catalysts, consists in preparing a metallic oxide hydro-sol which leads to the supported catalyst after deposition onto a support and an activation stage. In this work, this method has been adapted to the preparation of alumina supported bimetallic Pd-Sn catalysts to determine its interest for the control of the properties of the bimetallic phase (size, composition and structure). In the preliminary study concerning tin oxide sols, SnO{sub 2} (size=2,3 nm) and Sn{sub 6}O{sub 4}(OH){sub 4} (size = 25 nm) nano-particles were synthesized by neutralization respectively for tin(IV) and tin(H). The control through the pH of the aggregation of the PdO and SnO{sub 2} particles revealed that increasing oxide solubility promotes integral re-dispersion of the oxide particles. To synthesize oxide bimetallic sols, three strategies were defined. Copolymerization (formation of a mixed oxide ...

2001-09-01

492

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We report on new, spin-resolved magnetic microstructures, such as magnetic 'C' states and magnetic vortices, found at surfaces of FIB patterned ...

2005-04-01

493

Real-time optical modelling and investigation of inorganic nano-layer growth onto flexible polymeric substrates  

Energy Technology Data Exchange (ETDEWEB)

A major factor for the achievement of the desirable performance, efficiency and lifetime of flexible organic electronic devices is the optimization of the encapsulation layers that protect the device active layers by atmospheric gas molecule permeation. The active layers consisted of small molecule and/or polymer organic semiconductors as well as the organic conductors need to be encapsulated into a transparent medium that will provide the necessary protection and maintain their charge generation and transport characteristics. The encapsulation layers are generally consisted of inorganic thin films (silicon oxide-SiO{sub x} and aluminium oxide-AlO{sub x}) deposited onto the polymeric substrates, such as PolyEthylene Terephthalate (PET). In this work, in situ and real-time Spectroscopic Ellipsometry in the ultraviolet spectral region has been implemented in order to investigate the growth of inorganic SiO{sub x} and AlO{sub x} nano-layers onto PET flexible polymeric ...

2010-01-15

494

Combustion characteristics of fuel droplets with addition of nano and micron-sized aluminum particles  

Energy Technology Data Exchange (ETDEWEB)

The burning characteristics of fuel droplets containing nano and micron-sized aluminum particles were investigated. Particle size, surfactant concentration, and the type of base fluid were varied. In general, nanosuspensions can last much longer than micron suspensions, and ethanol-based fuels were found to achieve much better suspension than n-decane-based fuels. Five distinctive stages (preheating and ignition, classical combustion, microexplosion, surfactant flame, and aluminum droplet flame) were identified for an n-decane/nano-Al droplet, while only the first three stages occurred for an n-decane/micron-Al droplet. For the same solid loading rate and surfactant concentration, the disruption and microexplosion behavior of the micron suspension occurred later with much stronger intensity. The intense droplet fragmentation was accompanied by shell rupture, which caused a massive explosion of particles, and most of them were burned during this ...

2011-02-15

495

The Computation Directorate at Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The Computation Directorate at Lawrence Livermore National Laboratory has four major areas of work: (1) Programmatic Support -- Programs are areas which receive funding to develop solutions to problems or advance basic science in their areas (Stockpile Stewardship, Homeland Security, the Human Genome project). Computer scientists are 'matrixed' to these programs to provide computer science support. (2) Livermore Computer Center (LCC) -- Development, support and advanced planning for the large, massively parallel computers, networks and storage facilities used throughout the laboratory. (3) Research -- Computer scientists research advanced solutions for programmatic work and for external contracts and research new HPC hardware solutions. (4) Infrastructure -- Support for thousands of desktop computers and numerous LANs, ...

2006-09-07

496

Determination of anisotropic velocity model by reflection tomography of compression and shear modes; Determination de modele de vitesse anisotrope par tomographie de reflexion des modes de compression et de cisaillement  

Energy Technology Data Exchange (ETDEWEB)

As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, we extend the isotropic bending ray ...

2001-12-01

497

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography ...

2004-09-01

498

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the calcaneus, 15 from distal femur, 47 from the ...

1998-05-01

499

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle; CT und MRT erworbener Veraenderungen des Innenohrs und Kleinhirnbrueckenwinkels  

Energy Technology Data Exchange (ETDEWEB)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and cerebello-pontine angle. HRCT best depicts osseous ...

2003-03-01

500

Computer science handbook. Vol. 13.3. Environmental computer science. Computer science methods for environmental protection and environmental research  

International Nuclear Information System (INIS)

Environmental computer science is a new partial discipline of applied computer science, which makes use of methods and techniques of information processing in environmental protection. Thanks to the inter-disciplinary nature of environmental problems, computer science acts as a mediator between numerous disciplines and institutions in this sector. The handbook reflects the broad spectrum of state-of-the art environmental computer science. The following important subjects are dealt with: Environmental databases and information systems, environmental monitoring, modelling and simulation, visualization of environmental data and knowledge-based systems in the environmental sector. (orig.).