WorldWideScience
1

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

2

show expanded view - NAI: Ask an Astrobiologist  

Science.gov (United States)

I understand that you cannot answer truthfully because of the the janap 146e otherwise you would be commiting treason but please give a more intelligent ...

3

Suzanne Baldwin ? Profile ? Directory ? NASA Astrobiology  

Science.gov (United States)

The unified web presence for the NASA Astrobiology Program which includes the NASA Astrobiology Institute (NAI), Astrobiology Science and Technology for ...

4

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of ...

1997-05-01

5

Pharmacokinetic parameters for thallium (I)-ions in man  

Energy Technology Data Exchange (ETDEWEB)

The pharmacokinetics of Tl/sup +/ were studied in 9 patients who underwent myocardial scintigraphy with /sup 201/Tl/sup +/. The time course of the /sup 201/Tl/sup +/ concentration fitted to an open two-compartment model. Using previously published dialysance values the influence of hemodialysis on Tl/sup +/ elimination was calculated. Hemodialysis in Tl/sup +/ intoxications should be moderately effective.

1983-05-01

6

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma ...

2000-01-01

7

Measurement of electron energy fluence spectra from electron beam therapy machines  

Energy Technology Data Exchange (ETDEWEB)

A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. CYLTRAN, a coupled electron-photon Monte Carlo transport code, ...

1984-01-01

8

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer  

CERN Document Server

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer

1998-01-01

9

Modifications to the rotating crystal spectrometer  

International Nuclear Information System (INIS)

... bf3 counters data multi-channel analyzers multivibrators neutron spectrometers

10

Regulation of Na(+)-K+ pump activity in contracting rat muscle.  

UK PubMed Central (United Kingdom)

1. In rat soleus muscle, high frequency electrical stimulation produced a rapid increase in intracellular Na+ (Na+i) content. This was considerably larger in muscles contracting without developing tension...Full Text Available

1997-09-15

11

An analytic representation of the radial distribution of dose from energetic heavy ions in water, Si, LiF, and NaI  

International Nuclear Information System (INIS)

An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.

1989-09-01

12

As time goes by? The fallacy of thrombolysis in STEMI networks  

British Library Electronic Table of Contents (United Kingdom)

Primary percutaneous coronary intervention (PPCI) is superior to thrombolysis (TL) as reperfusion therapy in ST-elevation myocardial infarction (STEMI). TL is a rapidly available, but semi-effective therapy (effective reperfusion in 50% of patients only), whereas PPCI is a potentially delayed, but highly effective therapy (effective reperfusion in >90%). Since TL loses its efficacy beyond 2?3?h after symptom onset, it is a significant reperfusion alternative to PPCI in early presenters only. The individual decision to treat an early presenter with PPCI or TL requires the evaluation of the time delay between potential start of TL or PPCI, the PCI-related delay (PRD). PRD is greatest, if TL is given in the prehospital setting. Until now, prehospital TL as the most rapidly available reperfusi...

2011-01-01

14

Equilibrium and pre-equilibrium emissions in proton-induced reactions on "2"0"3","2"0"5Tl  

International Nuclear Information System (INIS)

In this study, the excitation functions for the reactions "2"0"3Tl(p, n)"2"0"3Pb, "2"0"5Tl(p, 3n)"2"0"3Pb, "2"0"3Tl(p, 2n)"2"0"2Pb, "2"0"5Tl(p, 4n)"2"0"2Pb, "2"0"3Tl(p, 3n)"2"0"1Pb, "2"0"5Tl(p, 5n)"2"0"1Pb, "2"0"3Tl(p, 4n)"2"0"0Pb and "2"0"5Tl(p, 6n)"2"0"0Pb have been calculated using pre-equilibrium and equilibrium reactions mechanisms. Calculated results based on hybrid model, geometry-dependent hybrid model and cascade-exciton model have been compared with the experimental data. (author)

2009-02-01

15

Infrared bleaching of the thermoluminescence of four feldspars  

International Nuclear Information System (INIS)

This paper studies the effect upon the thermoluminescence (TL) signal of four feldspar samples of exposing them to infrared stimulation, as occurs during infrared-stimulated luminescence (IRSL) measurement. Together with pulse annealing measurements these results are used to show which part of the TL signal is removed by exposure to IR and which part is directly related to the IRSL signal that is observed. When the samples are preheated prior to measurement in order to remove any low-temperature (< 200"oC) TL signals, a linear relationship is observed between the amount of TL that is lost and the IRSL light sum that is produced. The IRSL light sum is consistently four times larger than the amount of TL that is lost. Three possible explanations are proposed for this, but no conclusive evidence could be obtained to support any of them. A close similarity is observed in the pulse ...

1995-06-01

16

DECAY OF Ta$sup 177$ AND Lu$sup 177$ TO LEVELS IN Hf$sup 17$$sup 7$  

Science.gov (United States)

The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gamma spectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, ...

1961-10-15

17

Production of 'no-carrier-added' "2"0"1Tl  

International Nuclear Information System (INIS)

A procedure has been developed for producing a radiopharmaceutically pure ''no-carrier-added'' "2"0"1Tl. The procedure is based on irradiating enriched metallic thallium (> 96% "2"0"3Tl) targets with approx. 30 Mev protons, separating "2"0"1Pb by co-precipitation with SrSO_4 from sulphuric acid solution, and extracting "2"0"1Tl (after its in-growth) with butyl acetate from a hydrochloric solution. The average overall yield of "2"0"1Tl is approx. 92%. The radioactive concentration of the product exceeds 2 mCi/mL; radionuclide impurities-"2"0"0Tl <= 0.5%; "2"0"2Tl <= 0.1%; "2"0"3Pb <= 0.02%; inactive impurities (#mu#g/mL)-Tl < 2, Sr < 1, Fe < 0.25, Cu < 0.05; pH within the range 5-8. The product is sterile, apyrogenic, and suitable for clinical application. (author).

18

Determination of sodium in biological samples by instrumental neutron activation analysis  

International Nuclear Information System (INIS)

Sodium is one of the most essential elements needed for metabolic processes amongst human beings. It is consumed in the form of sodium chloride but it is also present in edible plant leaves. Sodium is mostly analyzed by flame photometric method, a destructive and time consuming technique. Sodium has been determined in some green leave vegetables samples-palak, radish, khatta palak (ambat chuka), chaulai leaves, chauli bean covers and its seeds by instrumental neutron activation analysis. The method involves irradiation of samples with thermal neutrons from "2"4"1Am-Be source and counting "2"4Na activity (half life 15 hr) from the reaction "2"3Na(n,#gamma#) "2"4Na. Activity due to 1.37 MeV photopeak was counted with a NaI(Tl) crystal coupled to gamma ray spectrometer. Green leaves of the vegetables were thoroughly washed, dried at constant temperature and powdered. Bowen's Kale powder was used as standard for measuring sodium abundances. About ...

1981-05-01

19

Non-linearity of pre-dose response and its effects on TL dating  

Energy Technology Data Exchange (ETDEWEB)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-15

20

Non-linearity of pre-dose response and its effects on TL dating  

International Nuclear Information System (INIS)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-01

21

NAI: Year 4 Annual Report - NASA Astrobiology Institute  

Science.gov (United States)

His talk was based on the suggestion that life on Earh has been a long but accelerating ..... a New Class of Submarine Hydrothermal System"; April 29, 2002 , ..... of media personnel, including radio, television, newspapers, and magazines. ...... "The Birth of Stars and Planets" (Denver Museum of Nature and Science ...

22

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

23

Separation of "2"0"3Pb from Tl_2O_3 target material using a hydrous zirconium oxide column with application to "2"0"1Tl preparation  

International Nuclear Information System (INIS)

Lead 203 has been used as a tracer for lead in the field of nuclear medicine for several years. It is produced in a cyclotron usually by proton or deuteron bombardment of a thallium target principally by the p,n or d,2n reaction on "2"0"3Tl or the p,3n or d,4n reaction on "2"0"5Tl. Several different methods have been reported for the separation of "2"0"3Pb from the thallium target. These generally involve a combination of precipitation and solvent extraction techniques. A new method has been developed for the separation of Pb from Tl using ion exchange chromatography over hydrous zirconium oxide (HZO). Lead is taken up by this inorganic ion exchanger at pH > 3 whereas Tl(I) is not. Lead can subsequently be eluted with acid of pH 1-1.5. The recovery of "2"0"3Pb has been approximately 75% and the Tl impurity level has not been in excess of 10 ppm. Reference is made to the ...

24

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO{sub 4}  

Energy Technology Data Exchange (ETDEWEB)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The ...

2005-10-15

25

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO_4  

International Nuclear Information System (INIS)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL ...

2005-10-01

26

The sup(187m)Ir isomer state and its decay scheme  

International Nuclear Information System (INIS)

... beta spectrometers comparative evaluations data decay electrons

27

The conversion spectrum of Sr"8"8  

International Nuclear Information System (INIS)

... beta spectrometers decay energy-level transitions k conversion l conversion

32

Myocardial perfusion SPECT in patients after myocardial infarction: Comparison of "2"0"1Tl and dual-isotope protocol (rest "2"0"1Tl/stress "9"9"mTc tetrofosmin)  

International Nuclear Information System (INIS)

The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI

1998-08-01

33

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to ...

1991-06-01

34

Luminescence characteristics for the detection of radiation treatment of shellfish by using isolated minerals  

International Nuclear Information System (INIS)

Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray ...

35

Purification of cyclotron-produced {sup 203}Pb for labeling Herceptin  

Energy Technology Data Exchange (ETDEWEB)

A simple and rapid procedure was developed for the purification of cyclotron-produced {sup 203}Pb via the {sup 203}Tl(d,2n) {sup 203}Pb reaction. A Pb(II) selective ion-exchange resin, with commercial name Pb Resin from Eichrom Technologies, Inc., was used to purify {sup 203}Pb from the cyclotron-irradiated Tl target with excellent recovery of the enriched Tl target material. The purified {sup 203}Pb was used to radiolabel the monoclonal antibody Herceptin. The in vitro and in vivo properties of the {sup 203}Pb radioimmunoconjugate were evaluated.

2005-04-01

36

Luminescence characteristics of LiCaAlF6:Eu phosphor  

British Library Electronic Table of Contents (United Kingdom)

A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

2007-01-01

37

Thallium-201 yields and excitation functions for the lead radioactivities produced by irradiation of natural thallium with 15-60 MeV protons  

International Nuclear Information System (INIS)

Excitation functions, production yields and radionuclidic purities are described for "2"0"1Tl production by the "2"0"3Tl(p,3n) "2"0"1Pb #-># "2"0"1Tl and "2"0"5Tl(p,5n)"2"0"1Pb#->#"2"0"1Tl nuclear reactions. The yields (mCi g"-"1 cm"2/#mu#A-hr) of the parent "2"0"1Pb(9.4hr), as well as the radiocontaminants "2"0"0Pb(21.5hr), sup(202m)Pb(3.62 hr), "2"0"3Pb(52.1 hr) and sup(204m)Pb(1.115 hr) were measured by irradiating a stack of thin natural Tl foils with protons from the 76-in isochronous cyclotron at the Crocker Nuclear Laboratory. The "2"0"1Tl thick-target yield (mCi/#mu#A hr) was calculated for different target thicknesses and corresponding incident proton energies. The excitation functions for the "2"0"3Tl(p,3n)"2"0"1Pb and "2"0"5Tl(p,5n)"2"0"1Pb reactions were measured in the 15-60-MeV ...

38

Calculation of the knight shift in the system CaCdsub(1-x)Tlsub(x) by using relativistic APW wave functions  

International Nuclear Information System (INIS)

For the intermetallic system CaCdsub(1-x)Tlsub(x), 0 <= x <= 1, the Knight shift Ksub(s) of the Cd-NMR and the Tl-NMR were calculated as a function of x, Ksub(s) = Ksub(s)(x). The theoretical investigations were performed on the basis of relativistic augmented-plane-wave (RAPW) band-structure calculations for the boundary phases CaCd and CaTl respectively, and by using the rigid band model for the ternary phases. The density of states and the matrix elements of the relativistic hyperfine operator for electron states at the Fermi surface were calculated in detail. The obtained values were compared with nonrelativistic calculations. The effect of using different exchange potentials was studied for Ksub(s)(Tl). For the Cd-NMR the relativistic effects enhance the nonrelativistic results by a factor of about 1.4. The theoretical value for the Knight shift is smaller than the experimental one by a factor of 1.13. The band ...

39

Analysis of thermoluminescence glow curves of minerals sphene and epidote for radiation damage studies  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence (TL) properties of sphene and epidote are of interest in studies related to their radiation damage. Natural and artificially induced TL of these minerals has, therefore, been investigated. Both minerals exhibit complex glow curves with several overlapping peaks. The Tsub(m) -Tsub(STOP) thermal cleaning procedure has revealed three peaks in the ..gamma.. ray induced glow curve of each mineral. That these peaks obey second order kinetics was indicated by the continuously slanting structure of the Tsub(m)-Tsub(STOP) curve. The TL parameters E and s have been calculated using (i) the initial rise method, and (ii) the glow-peak shape method. In general, the values of E calculated by the first method are found to be higher than those from the second. The TL curve-fitting method is also applied in order to calculate these parameters and to serve as a cross-check on the results.

1986-01-01

40

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...

1999-07-01

41

Interactions of metal cations with anionic groups on the cell Wall of the macroalga vaucheria sp.  

Energy Technology Data Exchange (ETDEWEB)

The aim of this article was to investigate the interactions of metal cations in aqueous solutions with the biomass of the freshwater macroalga Vaucheria sp. This problem is important when elaborating new applications of biosorption, e.g. the production of mineral feed additives for livestock from the biomass of algae enriched with microelement ions. Potentiometric titration was applied as a quick and cheap screening test to search for new efficient biosorbents. It revealed a variety of functional groups capable of cation exchange on the macroalgal surface, including carboxyl, phosphate, hydroxyl or amino groups. Fourier transform infrared spectroscopy on natural and chromium-loaded Vaucheria sp. confirmed that carboxyl groups played a dominant role in the biosorption. The study also showed that Ca(II), Na(I), K(I), and Mg(II) ions were released from the biomass after biosorption of Cu(II), Mn(II), Zn(II), and Co(II) ions, indicating that ion exchange was a key ...

2010-06-15

42

Suppression of afterglow in CsI:Tl by co doping with Eu"2"+-II: Theoretical model  

International Nuclear Information System (INIS)

The mechanism for afterglow suppression in codoped CsI:Tl,Eu reported in the preceding paper was investigated by combined radioluminescence and thermoluminescence experiments. Model rate equations informed by these experiments were employed to simulate afterglow. It was found that codoping with europium introduces deep electron traps, with room-temperature glow peaks, that effectively scavenge the electrons from shallow traps associated with thallium, thus suppressing afterglow in the time domain of tens of milliseconds.

2006-03-15

43

SEM and EDXS analysis of the reaction products of compounds A[sub x]M[sub 6]X[sub 8] (A = Tl, K; M = V, Ti; X = S, Se) with I[sub 2]/CH[sub 3]CN and H[sub 2]O. [TlVS; TlVSe; TlTiS; TlTiSe; KVS; KVSe; KTiS; KTiSe  

Energy Technology Data Exchange (ETDEWEB)

The ternary transition metal chalcogenides A[sub x]M[sub 6]X[sub 8] (A = Tl, K; M = V, Ti; X = S, Se) build up a three dimensional framework with large hexagonal channels running parallel to the crystallographic c-axis. The electropositive elements thallium or potassium are confined within these channels. It is possible to remove the Tl or K atoms via a chemical redox reaction with an I[sub 2]/CH[sub 3]CN solution or with H[sub 2]O. Using SEM it is demonstrated that the host matrix V[sub 6]S[sub 8]'' is only slightly affected by the redox agent. In contrast the host matrix Ti[sub 6]Se[sub 8]'' of Tl[sub x]Ti[sub 6]Se[sub 8] reacts with the I[sub 2]/CH[sub 3]CN solution. The results of the EDXS analyses clearly show that the removal of the electropositive elements proceeds only along the large channels and not through the host matrix. (orig.)

1994-05-01

44

LiF:Mg, Cu, P TL detectors with adjustable energy responses  

Energy Technology Data Exchange (ETDEWEB)

When used for tissue-equivalent monitoring, the thermoluminescence material LiF:Mg, Cu, P shows an 'under-response' to low-energy photons. This paper explores a new way to increase its low-energy response effectively, and to make it adjustable to some extent, by adding elements with high Z{sub eff}. At the same time its excellent thermoluminescente (TL) performance is maintained. (author).

1991-11-14

45

Effects of ischemic-like insult on myocardial /sup 201/Tl accumulation  

Energy Technology Data Exchange (ETDEWEB)

Despite extensive clinical use of thallium-201 (/sup 201/Tl) for myocardial imaging, the effect of ischemia on myocardial accumulation and release of /sup 201/Tl independent of flow has not been fully defined. Therefore, myocardial accumulation of /sup 201/Tl in response to ischemic-like myocardial injury was assessed in vitro using the cultured fetal mouse heart preparation. Cultured fetal mouse hearts (n . 311) were subjected to injury simulating ischemia by deprivation of oxygen and oxidizable substrates for periods ranging from 15 minutes to 10 hours. The extent of irreversible injury was determined by the percentage of lactic dehydrogenase (LDH) lost from the hearts to the culture medium during recovery from injury. Injury was essentially reversible at 1 hour of insult. The fraction of /sup 201/Tl content in injured compared with control hearts was not significantly lower after 1 hour of insult. By ...

1983-04-01

46

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

47

Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite  

Energy Technology Data Exchange (ETDEWEB)

The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, ...

2006-08-15

48

Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite  

International Nuclear Information System (INIS)

The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, ...

2005-07-24

49

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

50

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

51

USSR Report, Electronics and Electrical Engineering.  

Science.gov (United States)

... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...

1985-04-30

52

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

53

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

54

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

55

FOCUS: time-of-flight spectrometer for cold neutrons at SINQ  

Energy Technology Data Exchange (ETDEWEB)

The physical layout of the Time-Of-Flight spectrometer at the new spallation source SINQ is presented. The concept shows up a hybrid-TOF combining a Fermi-chopper with a crystal monochromator. The demand of a versatile and flexible instrument for several applications is taken into account by the option of switching from time-focusing to monochromatic focusing mode such that the spectrometer can be optimised for both quasielastic and inelastic scattering applications. (author) 5 figs., 2 tabs., 16 refs.

1996-11-01

56

A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations  

Science.gov (United States)

A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.

2004-12-01

57

The behavior of thermally and optically stimulated luminescence of SrAl2O4:Eu2+,Dy3+ long persistent phosphor after blue light illumination  

International Nuclear Information System (INIS)

The behavior of afterglow (AG), thermoluminescence (TL), infrared stimulated luminescence (IRSL) and phototransferred TL (PTTL) under thermal and/or infrared (IR) stimulation in blue (470 nm) light illuminated at room temperature (RT) SrAl2O4:Eu2+, Dy3+ is presented. The TL glow curve consists of four peaks with maxima at about 340, 430, 560 and 680 K. The 340 and 440 K peaks are described well by second order kinetics with activation energies of 0.83 and 1.05 eV, respectively. The AG decay is fitted by the Becquerel's law with exponent 1.5 and correlates well with the thermal emptying of the traps responsible for the 340 K peak. The 340 and 430 K TL peak traps are destroyed under IR (830 nm) stimulation creating IRSL. IR stimulation after illumination with blue light and preliminary heating restore partially the 340 and 430 K TL peaks by phototransfer from deeper traps. The shape ...

2008-02-01

58

Tumour affinity of [sup 203]Pb-chloride: comparison with [sup 67]Ga-citrate and [sup 201]Tl-chloride  

Energy Technology Data Exchange (ETDEWEB)

[sup 203]Pb-chloride is a promising imaging agent for tumour scanning because of the large retention value for tumour tissue and the small value for normal organs, but the large value for the kidneys and bone is a shortcoming. The retention value of [sup 203]Pb in tumour tissue is larger than that of [sup 201]Tl and smaller than that of [sup 67]Ga. The tumour/inflammatory lesion retention ratio for [sup 203]Pb is very large in comparison with those for [sup 67]Ga and [sup 201]Tl. [sup 203]Pb accumulates to a large extent in viable tumour tissue, and less in necrotic tumour tissue and in inflammatory lesion. (author).

1994-01-01

59

Thermoluminescence of irradiated RbCl and RbCl:Sn crystals  

International Nuclear Information System (INIS)

The thermoluminescence (TL) and emission of coloured RbCl and RbCl:Sn crystals are studied in the temperature range 300 to 560 K. The glow peaks responsible for F centres and tin centres in different valence states are identified using optical bleaching studies. The glow peaks are analysed using total curve fitting method and the kinetic parameters are determined. In moderately #gamma#-irradiated tin-doped RbCl crystals, the TL emission bands observed at 4.0, 3.6, and 2.2 eV are attributed to Sn"0, Sn"+, and Sn"- centers, respectively. A comprehensive energy level diagram depicting the various TL processes in these undoped and tin-doped RbCl crystals is proposed. (author).

60

Purification of cyclotron-produced "2"0"3Pb for labeling Herceptin  

International Nuclear Information System (INIS)

A simple and rapid procedure was developed for the purification of cyclotron-produced "2"0"3Pb via the "2"0"3Tl(d,2n) "2"0"3Pb reaction. A Pb(II) selective ion-exchange resin, with commercial name Pb Resin from Eichrom Technologies, Inc., was used to purify "2"0"3Pb from the cyclotron-irradiated Tl target with excellent recovery of the enriched Tl target material. The purified "2"0"3Pb was used to radiolabel the monoclonal antibody Herceptin. The in vitro and in vivo properties of the "2"0"3Pb radioimmunoconjugate were evaluated.

2005-04-01

61

Comparative study of infrared-stimulated luminescent and thermoluminescent dating of archaeological artefacts  

Energy Technology Data Exchange (ETDEWEB)

In this study, thermoluminescence (TL) dating of archaeological artefacts from Geboltskirchen (Upper Austria) and Haselbach (Lower Austria) has been carried out. To receive a comparison with TL dating, all samples have been investigated additionally by means of infrared-stimulated luminescence (IRSL) analysis. The samples were prepared according to the common fine-grain technique. All important dating parameters such as potassium concentration, thorium/uranium ratio, moisture content, etc. were determined. A methodology for IRSL was developed, describing all steps of the procedure from sample preparation to measurement for any kind of ceramic artefacts. Dating results from TL and IRSL investigations of ancient pottery from Geboltskirchen and Haselbach will be discussed.

2008-02-15

62

The use of calcium silicate bricks for retrospective dosimetry  

International Nuclear Information System (INIS)

The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples ...

2004-02-01

63

Nuclear data sheets update for A = 203  

Energy Technology Data Exchange (ETDEWEB)

Experimental results of nuclear reaction and radiative decay for A = 203 nuclides are evaluated. Adopted properties for all the nine isobars, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr of mass 203 are presented. Nothing is yet known for [sup 203]Os. 96 refs.

1993-09-01

64

Nuclear data sheets update for A = 203  

International Nuclear Information System (INIS)

Experimental results of nuclear reaction and radiative decay for A = 203 nuclides are evaluated. Adopted properties for all the nine isobars, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr of mass 203 are presented. Nothing is yet known for "2"0"3Os. 96 refs.

65

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements ...

2005-10-23

66

Idaho Explosives Detection System  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Explosives Detection System was developed at the Idaho National Laboratory (INL) to respond to threats imposed by delivery trucks potentially carrying explosives into military bases. A full-scale prototype system has been built and is currently undergoing testing. The system consists of two racks, one on each side of a subject vehicle. Each rack includes a neutron generator and an array of NaI detectors. The two neutron generators are pulsed and synchronized. A laptop computer controls the entire system. The control software is easily operable by minimally trained staff. The system was developed to detect explosives in a medium size truck within a 5-min measurement time. System performance was successfully demonstrated with explosives at the INL in June 2004 and at Andrews Air Force Base in July 2004.

2005-12-01

67

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

68

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

69

Additional Surveys of Natural Hot Springs in Nakorn Si Thammarat Province  

International Nuclear Information System (INIS)

Having know of four more natural hot spring located in Amphur Phipun, Nakorn Si Thammarat Province, the present investigators went on July 27, 2005 to collect water samples from the four new hot springs in Ampur Phipun, Nakorn Si Thammarat Province. The methods of collection and the determination of radon gas and free-living amoeba were the same as those employed in previous studies. The results revealed radon concentrations higher than the drinking safety limits of 11 Bq/L in specimens from Baan Huaysai Kow (32.30 Bq/L) and Baan Hunob (31.18 Bq/L; both naegleria and acanthamoeba were present in the specimens of the above two sites, whereas only naegleria recovered from Baan Huaysai Kow (Nai Nukul place) and none from Baan Nong Bua.

2005-12-01

70

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial ...

2003-09-15

71

Thermoluminescence emission of X-irradiated Eu{sup 2+} doped KBr single crystals  

Energy Technology Data Exchange (ETDEWEB)

In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with {approx} 50 ppm of Eu{sup 2+} ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at {approx} 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu{sup 2+} impurity acts as an electron trap during the irradiation process ...

1996-12-31

72

Thermoluminescence emission of X-irradiated Eu"2"+ doped KBr single crystals  

International Nuclear Information System (INIS)

In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with #approx# 50 ppm of Eu"2"+ ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at #approx# 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu"2"+ impurity acts as an electron trap during the irradiation process and that ...

73

PBAR: A superconducting magnet spectrometer for cosmic ray antiproton studies  

Energy Technology Data Exchange (ETDEWEB)

We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).

1990-09-15

74

A driving system for Moessbauer spectrometer  

International Nuclear Information System (INIS)

The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.

75

The cross sections of (n, x) nuclear reactions on Pb and Bi at the neutron energy 14.6 MeV  

International Nuclear Information System (INIS)

... compton spectrometers cross sections energy resolution energy-level transitions

2000-06-14

76

Remote Sensor Systems for Unmanned Planetary Missions  

Science.gov (United States)

instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...

77

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

78

Neutron time-of-flight spectroscopy and the reaction "8"8Sr("3He,n)"9"0Zr  

International Nuclear Information System (INIS)

... states helium 3 reactions ion sources mev range 10-100 neutron spectrometers

79

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

80

Quantitative thallium-201 scintigraphy after dipyridamole infusion combined with low level exercise in healthy volunteers  

Energy Technology Data Exchange (ETDEWEB)

To establish test specific normal limits for quantitative analysis of uptake and washout of /sup 201/Tl after dipyridamole infusion combined with low level exercise, 20 healthy volunteers were studied with low likelihood of coronary artery disease (CAD) assessed by a stepwise probability analysis based on age, sex, symptoms, resting electrocardiogram, and exercise electrocardiography. Likelihood of CAD in these volunteers was calculated as less than or equal to 1%. After dipyridamole infusion combined with low level exercise, one volunteer complained of headache; no other side effects were observed. There were no chest pain complaints. Maximal hemodynamic changes were achieved during the 6th and 7th min of the test. No ST segment depression was recorded. Visual analysis of the /sup 201/Tl scintigrams was normal in all volunteers. Mean regional washout at 4 h was 44.37%+-2.11%. The regional washout in the 70/sup 0/ LAO view (46.65%+-1.10%) was ...

1989-05-01

81

A critical look at the kinetic models of thermoluminescence-II. Non-first order kinetics  

Energy Technology Data Exchange (ETDEWEB)

Non-first order (FO) kinetics models are of three types; second order (SO), general order (GO) and mixed order (MO). It is shown that all three of these have constraints in their energy level schemes and their applicable parameter values. In nature such restrictions are not expected to exist. The thermoluminescence (TL) glow peaks produced by these models shift their position and change their shape as the trap occupancies change. Such characteristics are very unlike those found in samples of real materials. In these models, in general, retrapping predominates over recombination. It is shown that the quasi-equilibrium (QE) assumption implied in the derivation of the TL equation of these models is quite valid, thus disproving earlier workers' conclusion that QE cannot be held under retrapping dominant conditions. However notwithstanding their validity, they suffer from the shortcomings as stated above and have certain lacunae. For ...

2005-01-07

82

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

83

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

84

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

85

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

86

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

87

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

88

Utilization of Tc-99m-TBI as a myocardial perfusion agent in exercise studies: Comparison with Tl-201 thallous chloride and examination of its biodistribution in humans  

Energy Technology Data Exchange (ETDEWEB)

Twenty-four patients were studied with both /sup 201/Tl-thallus chloride and /sup 99m/Tc-TBI scintigraphy following exercise. Comparison of the two agents in detecting segmental myocardial ischemia and scar was made in 18 patients with evidence of coronary artery disease on /sup 201/Tl-thallous chloride scintigraphy. Agreement between the two studies was observed in 77% (125 of 162) of left ventricular segments, suggesting that /sup 99m/Tc-TBI can be used as a myocardial perfusion agent. Limitations were related to early high background activity from lungs and liver. The high lung activity and early myocardial redistribution within the 1st hour contributed to the failure of /sup 99m/Tc-TBI to detect 16 segmental defects seen in the immediate post-exercise thallous chloride scan. Persistently high liver activity additionally affected accurate interpretation in the left ventricular segments close to the diaphragm. Improvement in the accuracy of ...

1986-10-01

89

Positron annihilation in high-T/sub c/ superconductors  

International Nuclear Information System (INIS)

We report ab initio calculations of positron wave functions in the high-T/sub c/ superconductors YBa_2Cu_3O_7, Bi_2Sr_2CaCu_2O_8, and Tl_2Ba_2CaCu_2O_8 using the general potential linearized augmented plane-wave method. The calculated positron wave functions are fairly insensitive to whether or not electron-positron correlation is included in the calculation for YBa_2Cu_3O_7 and Tl_2Ba_2CaCu_2O_8, but the calculated positron density is quite sensitive to correlation in Bi_2Sr_2CaCu_2O_8. While the positron wave function samples primarily the chain region in YBa_2Cu_3O_7, the results indicate that positrons should be good probes of the Cu-O layer-derived electronic states near the Fermi energy in Tl_2Ba_2CaCu_2O_8 since a large overlap with these states is predicted.

90

Optimization of isotope production by cross section determination  

International Nuclear Information System (INIS)

In order to optimize the production of "2"0"1Tl and "6"7Ga using the (p, xn) reactions on enriched "2"0"3Tl and "6"8Zn targets we established a new set of cross section curves for the most relevant reactions. Target stacks made of up to 15 thin (50 #mu#m) natural Tl or Zn foils interleaved with brass degradation foils were irradiated with incident proton energies from 42 to 10 MeV in overlapping experiments. Yields for "2"0"0","2"0"1","2"0"2"m","2"0"3","2"0"4"mPB and "6"6","6"7","6"8Ga were computed from measured #gamma# emission rates. Where possible, cross section curves for the nuclear reactions involved were computed. Thick target yields and contamination ratios for enriched targets were derived and show good agreement with results from actual production runs. (orig.).

91

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS  

International Nuclear Information System (INIS)

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an ...

2010-07-11

92

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of ...

1998-06-01

93

MEMS-based Speckle Spectrometer  

CERN Document Server

We describe a new concept for a MEMS-based active spatial filter for astronomical spectroscopy. The goal of this device is to allow the use of a diffraction-limited spectrometer on a seeing limited observation at improved throughput over a comparable seeing-limited spectrometer, thus reducing the size and cost of the spectrometer by a factor proportional to r0/D (For the case of a 10 meter telescope this size reduction will be approximately a factor of 25 to 50). We use a fiber-based integral field unit (IFU) that incorporates an active MEMS mirror array to feed an astronomical spectrograph. A fast camera is used in parallel to sense speckle images at a spatial resolution of lambda/D and at a temporal frequency greater than that of atmospheric fluctuations. The MEMS mirror-array is used as an active shutter to feed speckle images above a preset intensity threshold to the spectrometer, thereby increasing ...

2006-01-01

94

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...

95

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

96

Separation of /sup 203/Pb by ion-exchange chromatography on Chelex 100 after production of /sup 203/Pb by the Pb(p,xn)/sup 203/Bi/sup EC. beta. +/ -> /sup 203/Pb nuclear reaction  

Energy Technology Data Exchange (ETDEWEB)

Bismuth radioisotopes, produced by 50-MeV proton bombardment of a lead target in a cyclotron, are separated from the lead target material by ion-exchange chromatography on a column containing 5.0 ml of Chelex 100. After a decay period of 24 hr, the /sup 203/Pb formed in situ is eluted from the column and then separated from /sup 200/Tl and /sup 201/Tl on a second ion-exchange column containing 0.5 ml of Chelex 100. Separations are sharp and carrier-free /sup 203/Pb is obtained.

1989-04-01

97

Nuclear magnetic resonance study of La_3X compounds and related phases  

International Nuclear Information System (INIS)

Normal state nuclear magnetic resonance studies of the La_3In, La_3Tl compounds have been made in order to investigate the origin of the large temperature-dependent magnetic susceptibility. It is possible to analyse the different contributions to the susceptibility using Knight-shift and relaxation time T_1 measurements of In"1"1"5 and Tl"2"0"5 nuclei. The exchange enhancement of the spin-susceptibility chisub(pd) is of the same order as that found in A-15 compounds and the strong temperature-dependence of chi(T) is attributed to the presence of a peak in the electronic density of states near the Fermi level. The variation of the Knight-shift in the ternary alloys La_3Xsub(1-y)Xsub(y)sup(') is analogous to that observed in the corresponding La_3X phases, on the other hand the Knight-shift in the carbides La_3XC is temperature independent. (author).

98

Cyclotron produced lead-203  

International Nuclear Information System (INIS)

The radioactive isotopes of lead are reviewed with respect to their choice for in vitro tracer studies. The #gamma#-photon energy and absence of particle emission in the decay of "2"0"3Pb makes it particularly suitable for these applications. Reaction yields of "2"0"3Pb using "2"0"3Tl targets and proton, deuteron, "3He and "4He beams are listed. Using the preferred reaction "2"0"3Tl (d, 2n)"2"0"3Pb with a 15 MeV deuteron beam, yields of about 75 #mu#Ci #mu#Ahr"-"1, after chemical separation, are reported. Details of target design and chemical separation are given. (U.K.).

99

{open_quotes}Pre-residue{close_quotes} light charged particles from {sup 28}Si+{sup 165}Ho and {sup 16}O+{sup 197}Au, {sup 208}Pb fusion  

Energy Technology Data Exchange (ETDEWEB)

Proton and alpha particle spectral shapes and multiplicities have been measured in coincidence with evaporation residues from {sup 28}Si+{sup 165}Ho and {sup 16}O + {sup 197}Au, {sup 208}Pb fusion reactions. Our experiments used 145 to 220 MeV {sup 28}Si and 115 and 140 MeV {sup 16}O beams produced with the Stony Brook LINAC. ER`s were separated using an electrostatic deflector and detected with large area surface barrier detectors. Light charged particles were detected at forward and backward angles with fourteen single NaI detectors. In the context of the statistical model, charged particle spectra yield information about emission barriers and compound nucleus equilibrium level densities. These are significant ingredients in calculations determining fission timescales from other observables such as pre-scission neutron multiplicities or fusion-evaporation excitation functions. Results will also be compared to analyses of pre-scission charged particles from ...

1993-10-01

100

The E = mc{sup 2} exhibition  

Energy Technology Data Exchange (ETDEWEB)

The goal of this DOE-supported exhibition is to demystify Einstein`s formula E = mc{sup 2} by illustrating the interchangeability of matter (m) and energy (E), c{sup 2} being the exchange rate. The exhibition has two major parts, {open_quotes}matter into energy{close_quotes} and {open_quotes}energy into matter{close_quotes}, plus a video to connect them. {open_quotes}Matter into energy{close_quotes} has now been completed and has been placed on the museum floor. Positrons from a {sup 22}Na source are annihilated to produce gamma rays that are caught in NaI detectors. The viewer can alter the alignment of the detectors and observe the consequences for the rates of single and coincident counts. The viewer can also observe the effects of placing absorbers in front of the counters. Prototype explanatory graphics were placed around the exhibit and those will probably be changed after we have some experience with their effectiveness. The connecting video is in the ...

1995-08-01

101

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can avoid these demerits. This analysis method was applied to the ...

1996-10-01

102

Numerical analysis of natural convection in a square cavity at high Rayleigh numbers using the GSMAC finite-element method. GSMAC yugen yosoho ni yoru ko Rayleigh su seihokei cavity nai shizen tairyu no hi teijo kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Stable and accurate numerical analytical method even at high Rayleigh numbers is desired, and in addition flexibility and economical efficiency are very important for numerical analysis. Unsteady flows of natural convention in a square cavity are investigated using the GSMAC (generalized and simplified marker and cell) finite-element method at high Rayleigh numbers from 10 {sup 6} to 10 {sup 8}. Validities of the multi-pass algorithm and BTD (balancing tensor diffusivity), which are highly accurate solutions for finite-element method, are investigated by introducing them to the GSMAC finite-element method. As the result, it was found that the multi-pass algorithm has little effect for the GSMAC finite-element method. The steady solutions at the Rayleigh numbers of 10 {sup 5} and 10 {sup 7} agreed well with the bench mark solutions and numerical solutions. Complex transient phenomena at Rayleigh numbers higher than 10 {sup 7} are successfully observed. 12 refs., 11 figs., 4 tabs.

1990-10-25

103

Effect of water content on the activity of lipase-hydrolysis of olive oil in reverse micelles. Gyakuso micelle nai ni okeru lipase no olive oil kasui bunkai hanno no gansuiritsu izonsei  

Energy Technology Data Exchange (ETDEWEB)

Hydrolysis of olive oil by Chromobacterium viscosum lipase was studied in a reverse micellar system of a anionic surfactant Aerosol OT (AOT) and isooctane. Different methods of solubilization of the micellar system afford specific dependence of enzymatic activity of the lipase on the water content in the micelles. In an injection method, water content is controlled by the amount of injected water, which determines the micelle size and hydrophobicity of the micelle without salt addition and changes reversibly the conformation of lipase corresponding to the change of lipase activity. The activity reaches the maximum at a water content (water/AOT)of 7. In a phase transfer method, water content is determined by salt concentration in the aqueous phase in contact with micelles and the water content corresponding to the maximum activity is 12 to 13, below which the activity decrese drastically. Addition of taurodeoxycholic acid to the AOT micelles suppresses the reversible conformational ...

1992-01-10

104

A Radiation Laboratory Curriculum Development at Western Kentucky University  

Science.gov (United States)

We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and Radiation Biophysics). Our goal is to develop a set of ...

2009-03-10

105

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best ...

2006-12-21

106

lla4892q.305  

Science.gov (United States)

PeDEL GRcXPmDtlSEZ`H==>T32\\ZtrPOP6tM UKwNEH5|J?:O TONRHwIN O1?)J`MiO\\ ?CQBYIL robb_M RSM7A8: qL6;90f44:7\\I07QO AE/U U_PbqIBYc6mTL?:2NDerX=Z =P<;K aRITGUN ...

107

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

108

Solution of Bohr's collective Hamiltonian for transitional odd-mass nuclei  

International Nuclear Information System (INIS)

A numerically feasible method, based on the use of deformed phonons, is developed for the diagonalization of the collective quadrupole Hamiltonian for a system with an odd particle coupled to an anharmonic even core. Examples: the transition from prolate to oblate via #gamma#-unstable shapes and furthermore the hsub(9/2) spectra of the nuclei "1"8"7Ir and "1"9"7Tl. (Auth.).

109

Optically stimulated luminescence (OSL) study of synthetic stishovite  

International Nuclear Information System (INIS)

Optically stimulated luminescence (OSL) of synthetic stishovite was investigated for a future dating technique of meteor impact craters. Luminescence around 330 nm was measured on the #gamma#-ray irradiated stishovite under two stimulating light sources of infrared laser (830 nm) and blue light emitting diode set (470 nm). Thermoluminescence (TL) studies before and after the OSL measurements showed the intensities around 100-200 deg. C and 220-350 deg. C to increase and those around 350-450 deg. C to decrease. This indicates that a part of deep-trapped charges excited during the OSL measurements were retrapped by shallower traps. The infrared stimulated luminescence (IRSL) after the TL measurement up to 450 deg. C could not be detected, while the blue light stimulated luminescence (BLSL) after TL had about one-tenth of the intensity before TL. This indicates that a part of the charges in shallower traps ...

2000-12-15

110

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

111

Large scale rooftop photovoltaics grid connected system at Charoenphol-Rama I green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a technical feasibility study project for the large scale rooftop photovoltaics (PV) grid connected system at Charoenphol-Rama I green building super store of TESCO LOTUS (TL) in Thailand. The objective of this project is (i) to study the technical feasibility of installation 350 kWp PV systems on the top of the roof in this site (ii) and to determine the energy produce from this system. The technical factors are examined using a computerized PVS 2000 simulation and assessment tool. This super store building located in Bangkok, with latitude 14 N, longitude 100 E and the building direction is 16 from North direction. The building roof area is 14,000 m2; with 3 degree face East and 3 degree face West pitch. Average daily solar energy in this area is approximately 5.0 kWh. The study team for this project consists of educational institution as School of Renewable Energy Technology (SERT) and private institution as Panya Consultants (PC). ...

2004-07-01

112

Anomalous solvent extraction behavior of astatine  

International Nuclear Information System (INIS)

We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).

113

Alpha particle induced TL supralinearity in TLD-100: dependence on vector properties of the radiation field  

Energy Technology Data Exchange (ETDEWEB)

The linear/supralinear behaviour of the TL dose response in LiF:Mg,Ti (TLD-100) and its dependence on ionisation density is a fairly unique phenomenon which cannot be explained by conventional atomic 'conduction band/valence band' kinetic models. The Track Interaction Model (TIM) provides the microscopic framework which, when coupled with other appropriate physical mechanisms (spatial localisation of traps and recombination centres, competing centres, variations in the capture cross sections with temperature, etc.) can be used to describe all the dominant features of the TL supralinearity of LiF:Mg,Ti and similar TL systems. The unique feature of the TIM applied to alpha particles is that it is an integral approach with only one free parameter, the average charge carrier migration distance in the luminescence recombination stage. Although the TIM provides a comprehensive description of the mechanisms ...

1993-01-01

114

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

115

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

116

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...

2010-11-11

117

Measurement of fission cross sections for nuclear transmutation on Am-241, Am-242m and Am-243 using lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)

1997-12-31

118

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.

1998-08-01

119

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)

1999-02-01

120

Diode laser overtone spectroscopy of CO_2 at 780nm  

International Nuclear Information System (INIS)

Overtone absorption lines of "1"2C"1"6O_2 have been examined by using a tunable diode laser (TDL) spectrometer in the region around 12770cm"-"1. The spectrometer sources are commercially available double heterostructure InGaAlAs TDLs operating in the 'free-running' mode, which allowed the detection of the line positions within 0.01cm"-"1. The observed carbon dioxide absorption lines belong to the #nu#_1+5#nu#_3 ro-vibrational band with rotational quantum number J up to 48. The minimum absorbance detected by the spectrometer (#approx#5x10"-"6) permitted to observe the weakest lines having the absorption cross section of the order of #approx#1x10"-"2"7cm"2/molecule.

2005-12-01

121

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement ...

1985-07-03

122

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.

123

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-09-01

124

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

125

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...

2008-02-01

126

Revision I July 29, 2009 - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

MIL-STD-129. N. 5/15/97. Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 ...

127

Project Technical ... - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 D. Notice 1. 12/15/99. 05/10/ 02 ...

128

Expert overseer for mass spectrometer system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The ...

1991-06-18

129

Expert overseer for mass spectrometer system  

International Nuclear Information System (INIS)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The ...

1989-04-04

130

AMS Project Plan - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Feb 19, 2009 ... Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1. D. Notice 1 ...

131

A new analysis for membrane noise. The integral spectrum.  

UK PubMed Central (United Kingdom)

A new method of random data analysis has been developed with special implications for membrane noise. The integral spectrometer uses overlapping broad-band filters of simple design, whose bandwidth...Full Text Available

1976-07-01

132

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

133

Results from a Bragg Curve Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-01-01

134

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-10-22

135

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

136

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

137

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

138

Large solid angle Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.

1984-02-01

139

In-place testing of HEPA filter systems by the single-particle, particle-size spectrometer method  

Energy Technology Data Exchange (ETDEWEB)

This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.

1981-12-01

140

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

141

Application of the digital waveform analysis to Bragg curve spectrometer  

International Nuclear Information System (INIS)

Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)

2004-11-01

142

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

143

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

144

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated ...

1999-11-01

145

Yield and excitation function measurements of some nuclear reactions on natural thallium induced by protons leading to the production of medical radioisotopes {sup 201}Tl and {sup 203}Pb  

Energy Technology Data Exchange (ETDEWEB)

Excitation functions for {sup 201}Pb, {sup 202m}Pb, {sup 203}Pb and {sup 204m}Pb radionuclides which are formed via proton induced reactions with natural thallium target have been measured from their respective threshold (E{sub thr}) to 27.5 MeV using activation technique. Natural copper foils were used to monitor the cyclotron beam. The integral yields (MBq/{mu}A h) of the produced radionuclides were calculated from the measured excitation functions. The optimum proton energy range for the production of {sup 203}Pb with low amount of impurities is (16-10 MeV) after 5 h of EOB. The experimental cross-sections for {sup nat}Tl(p,xn) reactions were compared with the cross-sections recommended by the IAEA and with earlier published data when it was possible. (orig.)

2007-07-01

146

Usefulness of myocardial imaging by [sup 123]I-MIBG in assessment of diabetic neuropathy  

Energy Technology Data Exchange (ETDEWEB)

In diabetic patients with autonomic neuropathy, it is suggested that there is a reduced uptake of [sup 123]I-metaiodobenzylguanidine (MIBG) in the heart. We compared the difference of myocardial [sup 123]I-MIBG accumulation between 4 diabetic patients with triopathy and 6 patients without it. In all 10 patients, coronary angiography and [sup 201]Tl imaging (rest and 4 hours later) were performed. [sup 123]I-MIBG (111 MBq) was administered intravenously and its imaging was recorded on 15 minutes and 4 hours after injection. In all 4 cases with triopathy, [sup 123]I-MIBG imaging showed defect in apical and inferior region. In 2 out of 6 cases without triopathy, rapid clearance was noticed in apical and inferior region. There was no significant stenosis in right coronary artery and no defect in initial and delayed [sup 201]Tl images in all cases. We concluded that diabetic autonomic neuropathy in the heart was prominent in apical and inferior ...

1993-10-01

147

The response of some TL albedo neutron dosimeters  

International Nuclear Information System (INIS)

As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its response varies roughly as the cosine of the angle of incidence but is more complex at higher energies. (author).

148

Preliminary study of the application of natural olivine in Cenozoic dating  

Energy Technology Data Exchange (ETDEWEB)

The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL signal component ...

2006-08-15

149

NMR in highly correlated superconductors  

International Nuclear Information System (INIS)

Results of our systematic NMR study in high T_c cuprates are reviewed. The antiferromagnetic spin fluctuations (AFSF) decrease in the order of La_1_._8_5Sr_0_._1_5CuO_4. YBa_2Cu_3O_7 and Tl_2Ba_2CuO_6_+_y. 1/T_1 of "6"3Cu in the CuO_2 plane in the normal state follows essentially a Curie-Weiss law at high temperature and T_1T = const. law at low temperature. The temperature dependence of 1/T_1 and the Knight shift together with their impurity effect in the superconducting state strongly suggest d-wave pairing implying the AFSF to be responsible for the occurrence of superconductivity. From the NQR frequency measurement the density of Cu 3d and O 2p holes decreases and increases, respectively, in the order of La, Y and Tl compounds, which is consistent with the change of AFSF. The relation between T_c and #nu#_Q, and their pressure dependence suggest that there exists and optimum value of the ratio of Cu 3d and O 2p hole density to give a ...

1992-08-01

150

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.

2008-05-22

151

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

152

The production of carrier-free lead-203  

International Nuclear Information System (INIS)

The chemical separation of carrier-free "2"0"3Pb following deuterium bombardment of a "2"0"3Tl target is described. Coprecipitation from strontium sulphate was used to separate the "2"0"3Pb from a solution of the thallium target in sulphuric acid. The SrSO_4 precipitate was filtered, washed and dissolved in hydrochloric acid, from which "2"0"3Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given. (U.K.).

153

The 8{pi}LP Project: A 4{pi} light charged particle detection array at LNL  

Energy Technology Data Exchange (ETDEWEB)

A 4{pi} detection system sensitive to light charged particles is being developed at the Laboratori Nazionali di Legnaro (LNL) for the study of reaction mechanisms at energies up to 20 AMeV. The array consists of 262 {Delta}E-E telescopes covering 90% of 4{pi}. Each telescope is made of a 300 {mu}m passivated silicon detector and a 15 mm (or 5 mm) CsI(Tl) crystal read by a photodiode. The system will be operational in the Spring of 1997 and the first experiments will run in the second half of 1997.

1996-12-31

154

Shielded and unshielded geometries in the search for orphan sources  

Energy Technology Data Exchange (ETDEWEB)

A car-borne NaI(Tl) spectrometric system was used together with a {sup 137}Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-15

155

Shielded and unshielded geometries in the search for orphan sources  

International Nuclear Information System (INIS)

A car-borne NaI(Tl) spectrometric system was used together with a "1"3"7Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-01

156

Production of carrier-free lead-203  

Energy Technology Data Exchange (ETDEWEB)

The chemical separation of carrier-free /sup 203/Pb following deuterium bombardment of a /sup 203/Tl target is described. Coprecipitation from strontium sulphate was used to separate the /sup 203/Pb from a solution of the thallium target in sulphuric acid. The SrSO/sub 4/ precipitate was filtered, washed and dissolved in hydrochloric acid, from which /sup 203/Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given.

1982-07-01

157

Primary standardization of {sup 242} Am radioactive sources  

Energy Technology Data Exchange (ETDEWEB)

The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)

2001-07-01

158

Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92  

International Nuclear Information System (INIS)

The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.

1989-01-01

159

Nondestructive analysis for "2"3"2U and decay progeny in animal tissues  

International Nuclear Information System (INIS)

Direct determination of "2"3"2U and its decay products in animal tissues appears to be feasible using an intrinsic Ge(Li) diode detector (for energies of 5-100 keV) and a NaI(Tl) anticoincidence-shielded Ge(Li) diode for higher-energy gamma photons. The detection sensitivity for "2"3"2U and "2"2"8Th is 0.03 and 0.01 nCi, respectively, using a 300-min counting time.

1977-05-01

160

Modification of NPL-CRC secondary standards radionuclide calibrator holder to suit for IPEN vials  

International Nuclear Information System (INIS)

The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)

2000-10-05

161

A new method for the analysis of infrared stimulated luminescence data from potassium feldspars  

International Nuclear Information System (INIS)

A new method is described for the analysis of high precision pulse annealing data obtained using IRSL measurements on potassium feldspars using a Risoe reader. Presenting the data as the percentage of the signal lost per annealing phase permits more detailed comparisons to be made between samples. In addition, it is possible to directly compare the temperatures at which the TL and IRSL signals are released, thus giving information about the relationship between them. This method of analysis is applied to pulse annealing data for natural, irradiated, preheated and IR bleached aliquots. (author).

1993-07-01

162

[sup 123]I-MIBG myocardial scintigraphy in diabetic patients. Relationship with [sup 201]Tl uptake and cardiac autonomic function  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to investigate the influence of diabetic myocardial damage (suspected myocardial damage; SMD) diagnosed by [sup 201]Tl-SPECT and diabetic cardiac autonomic neuropathy (AN) on myocardial MIBG uptake in patients with NIDDM. Eighty-seven diabetic patients divided into four subgroups: 23 with SMD (+) AN (+); 19 with SMD (+) AN (-); 27 with SMD (-) AN (+); 18 with SMD (-) AN (-), and 10 controls were studied. Both planar and SPECT images were taken at 30 minutes (early) and 3 hours (delayed) after [sup 123]I-MIBG injection. The heart to mediastinum uptake ratio (H/M) and washout ratio of [sup 123]I-MIBG (WR) were obtained from both planar images. Similarly, the difference between the [sup 201]Tl image and the [sup 123]I-MIBG image in the total uptake score (TUS) was taken as the difference in the total uptake score ([Delta]TUS) representing cardiac sympathetic denervation without SMD. On both early and delayed planar ...

1998-12-01

163

Syntheses and crystal structures of the compounds In_3_._7Mo_1_5S_1_9, In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9 and ScTl_2Mo_1_5S_1_9 containing Mo_6 and Mo_9 clusters  

International Nuclear Information System (INIS)

The new compounds In_3_._7Mo_1_5S_1_9, In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9, and ScTl_2Mo_1_5S_1_9 have been synthesized by solid-state reaction in sealed molybdenum crucible at about 1250 deg. C. Their crystal structures were solved and refined from X-ray single-crystal data in the hexagonal space group P63/m. Their Mo-S framework consists of an equal mixture of Mo_6S_8S_6 and Mo_9S_1_1S_6 cluster units interconnected through Mo-S bonds. In In_3_._7Mo_1_5S_1_9, the In atoms occupy crystallographically different positions depending on their formal oxidation states of +1 or +3. This was confirmed by replacing partially or totally the monovalent indium by another monovalent cation such as the rubidium, cesium or thallium and the trivalent indium by the scandium to get the new In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9, and ScTl_2Mo_1_5S_1_9 compounds, respectively.

2004-11-30

164

Respiratory impairment due to asbestos exposure in brake-lining workers  

International Nuclear Information System (INIS)

There is extensive evidence that exposure to asbestos causes pulmonary parenchyma fibrosis, pleural disease, and malignant neoplasm in asbestos-exposed workers. However, few data concerning brake-lining workers are available in the literature. In this study, we aimed to assess the long-term effects of chrysotile asbestos exposure on lung function and the risk of asbestos-related diseases in brake-lining workers. Seventy-four asbestos-exposed workers who processed brake-lining products and 12 unexposed office workers were offered pulmonary function tests (spirometry and transfer actor) in 1992 and 1999. In 1999, the mean duration of asbestos exposure was 0.00#+-#4.07 and 11.02#+-#4.81 years (7-31 years) in non smoking and smoking asbestos workers, respectively. Transfer factor (T_L, CO) and transfer coefficient (K_C_O) decline were significant in the 7-year follow-up in both smoking and non smoking asbestos workers. However, lung function indices of he control ...

2003-03-01

165

Intrinsic Dosimetry Of Glass Containers Used To Transport Nuclear Materials: Potential Implications to the Field of Nuclear Forensics  

International Nuclear Information System (INIS)

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of ...

166

35 years of Thermoluminescence Dosimetry (TLD) in personnel and environmental monitoring in India - a tribute to Dr. K G Vohra  

International Nuclear Information System (INIS)

Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully ...

167

Multipass laser mass spectrometer with extreme jet-cooled pulsed gas  

International Nuclear Information System (INIS)

We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution ...

2006-09-01

168

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been ...

2007-01-01

169

Feasibility study of large combined function magnets for the Jefferson lab 12 GeV upgrade  

CERN Document Server

The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current densities are ...

2005-01-01

170

An overview on the study of quark gluon plasma with Alice dimuon spectrometer; Apercu sur l'etude du plasma de Quarks et de gluons a l'aide du spectrometre dimuons d'Alice  

Energy Technology Data Exchange (ETDEWEB)

The Alice experiment is one of the four main LHC (Large Hadron Collider) experiments. It is dedicated to the study of a new state of matter: the quark gluon plasma, where quarks and gluons are no longer confined within hadrons. In this document, the physics issues that led to the construction of Alice dimuon spectrometer, are described. Then, the research and development on the dimuon spectrometer is presented. The different absorbers are described and experimental tests used to determine their dimensions are presented. The dimuon trigger built using the RPC (Resistive Plate Chamber) streamer mode is then described along with the associated beam and cosmic tests and results. Finally, the tracking system is described in detail and more particularly all its electronics and the first station. The physics constraints on the expected performances of all these systems are clearly defined. (author)

2007-10-15

171

Purification and characterization of (-)(/sup 125/I)hydroxyphenylisopropyladenosine, an adenosine R-site agonist radioligand and theoretical analysis of mixed stereoisomer radioligand binding  

Energy Technology Data Exchange (ETDEWEB)

(-)-N6-(R-4-Hydroxyphenylisopropyl)adenosine (HPIA) was iodinated with NaI and trace /sup 125/I. Mono- and diiodinated reaction products and the starting material were separated by high pressure liquid chromatography and the structures of the reaction products were verified by NMR. (-)-N6-(R-Phenylisopropyl)adenosine (PIA), IHPIA, and I2HPIA decreased rat atrial contractility with ED50 values of 24, 28, and 33 nM, respectively. The contractile effects of these compounds were competitively blocked by theophylline (KI . 7.9 microM), but were not affected by adenosine deaminase. IHPIA also inhibited (-)isoproterenol-stimulated cyclic AMP accumulation in adipocytes with an ED50 (10 nM) and to an extent (83%) nearly identical to PIA. (/sup 125/I)HPIA prepared using carrier-free /sup 125/I bound to adenosine receptors on membranes from rat cerebral cortex, adipocyte ghosts, and heart ventricles. Binding was inhibited stereospecifically by PIA and by other adenosine ...

1984-11-01

172

Testing measurements at horizontal channels of the MARIA reactor performed using neutron spectrometers; Pomiary testowe przy kanalach poziomych reaktora MARIA wykonane przy uzyciu spektrometrow neutronow  

Energy Technology Data Exchange (ETDEWEB)

By means of neutron diffraction, using the standard polycrystalline sample of Al{sub 2}O{sub 3}, measurements on three (of four spectrometers) already installed in the front of horizontal channels of MARIA reactor have been performed. Basing on these experiments as well as on activation measurements carried out earlier, the fluxes of monoenergetic neutrons have been estimated. These experiments allowed to determine (for a given geometry and kind of monochromators chosen) the resolution efficiency of instruments and high order contamination in the reflected beam. With the help of polycrystalline vanadium and TbBr{sub 3} sample, the possibility of studies using the inelastic scattering process have been tested. (author) 7 refs, 15 figs, 7 tabs

1997-12-31

173

Surface analysis by Fourier-transform infrared (FTIR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.

1981-08-12

174

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.

1984-10-01

175

Rapid Sampling of Individual Organic Aerosol Species in Ambient Air with the Photoionization Aerosol Mass Spectrometer  

British Library Electronic Table of Contents (United Kingdom)

Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...

2008-01-01

176

Measurement of the relaxation time of hot electrons in laser-solid interaction at relativistic laser intensities  

Energy Technology Data Exchange (ETDEWEB)

The authors have measured the relaxation time of hot electrons in short pulse laser-solid interactions using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. Employing laser intensities of 10{sup 17}, 10{sup 18}, and 10{sup 19} W/cm{sup 2}, they find increased laser coupling to hot electrons as the laser intensity becomes relativistic and thermalization of hot electrons at timescales on the order of 10 ps at all laser intensities. They propose a simple model based on collisional coupling and plasma expansion to describe the rapid relaxation of hot electrons. The agreement between the resulting K{sub {alpha}} time-history from this model with the experiments is best at highest laser intensity and less satisfactory at the two lower laser intensities.

2006-08-22

177

Continuous-wave cavity ringdown spectroscopy of the Formula Not Shown Meinel system (2,1) band  

British Library Electronic Table of Contents (United Kingdom)

The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...

2008-01-01

178

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

179

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

180

The PAMELA space mission  

Energy Technology Data Exchange (ETDEWEB)

The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.

2009-03-15

181

Survey of naturally radioactive level of some new type wall materials  

International Nuclear Information System (INIS)

Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)

2006-09-01

182

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

183

Spectroscopic detection  

Energy Technology Data Exchange (ETDEWEB)

In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.

2003-01-01

184

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

185

SOME RECENT DETERMINATIONS OF ATOMIC MASSES IN THE STRONTIUM-ZIRCONIUM REGION  

Science.gov (United States)

A large double-focusing mass spectrometer was used to obtain new values for the masses of Sr/sup 86/, Sr/sup 88/, and Zr/sup 90/. Mass differences calculated from these values are found to be in better agreement with nuclear transmutation information than were previous mass spectroscopically derived values. (auth)

1960-06-01

186

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

187

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

188

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

189

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

190

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

191

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

192

Highly efficient ion source for analysis of transuranium elements  

Energy Technology Data Exchange (ETDEWEB)

Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.

1987-01-01

193

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

194

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

195

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

196

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

197

Cylindrical drift chamber with three-dimensional data readout  

International Nuclear Information System (INIS)

A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.

198

Cylinder drift chamber with three-dimensional data output  

Science.gov (United States)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

1995-03-01

199

Cylinder drift chamber with three-dimensional data output  

International Nuclear Information System (INIS)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

200

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

201

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

202

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

203

Application of neural networks to pulse-shape analysis of Bragg curves  

Energy Technology Data Exchange (ETDEWEB)

A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.

2006-01-15

204

An emulation and management software for MCA with 64 independent coded inputs  

International Nuclear Information System (INIS)

A Software for the Neutron Scattering time-of-flight Spectrometer with 64 independent coded inputs is preset. It performs data acquirement and management. The work platform of the software is the Windows 98 and programmed with Visual Basic 6.0. It supports 64 x 1024 channel analyzer computer system. The friendly interface, convenient operation and high reliability are advantages of the Software

2000-09-07

205

Absolute absorption of ozone in the midinfrared  

Energy Technology Data Exchange (ETDEWEB)

The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.

1992-12-20

206

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating from room temperature (RT) up to 500 deg. ...

2009-04-15

207

In vitro evaluation of herpes simplex virus type 1 thymidine kinase reporter system in dynamic studies of transcriptional gene regulation  

Energy Technology Data Exchange (ETDEWEB)

The herpes simplex virus type 1 thymidine kinase (HSV1-TK) reporter system is being used to directly and indirectly monitor therapeutic gene expression, immune cell trafficking and protein-protein interactions in various living animals. However, the issues of HSV1-TK enzyme stability in living cells and whether this reporter system is optimal for dynamic studies of gene expression events in genetic imaging have not be addressed. The purpose of the present study was to evaluate the application of this reporter system in dynamic studies of transcriptional gene regulation. To achieve this purpose, we established two tetracycline-inducible murine sarcoma cell lines, tetracycline-turn-off HSV1-tk-expressing cell line (NG4TL4/tet-off-HSV1-tk) and tetracycline-turn-off Luc-expressing cell line (NG4TL4/tet-off-Luc), to create an artificially regulated gene expression model in vitro. The dynamic transcriptional events mediating a series of doxycycline ...

2006-07-15

208

Ultratrace determination in high purity molybdenum and tungsten with ion chromatographic trace-matrix-separation. Pt. 2; Ultra trace analysis using ion chromatography. Ultraspurenanalytik in hochreinem Molybdaen und Wolfram mit ionenchromatographischer Spuren-Matrix-Trennung. Tl. 2; Ionenchromatographische Ultraspurenanalyse  

Energy Technology Data Exchange (ETDEWEB)

The use of high-performance ion exchangers allows a trace-matrix-separation (SMT) directly followed by an ion chromatographic (IC) separation of the analytes. Based on the principles described in Part 1, a combined procedure IC-SMT-IC for metallic impurities in Mo and W is presented. Up to 12 metal traces (Fe, Cu, Pb, Zn, Ni, Co, Cd, Ca, Mn, Sr, Mg and Ba) can be determined in one run with 35 min. A special method for traces of U and Th is also given. Detection limits are typically 10-100 ng g{sup -1} in the metal sample. (author). 14 refs.; 10 figs.; 6 tabs.

1992-01-31

209

The effect of trace elements on the fatigue behaviour of a carbide-hardened Fe-Ni-Cr alloy. Der Effekt von Spurenelementen auf das Zeitstandverhalten einer karbidverfestigten Fe-Ni-Cr-Legierung  

Energy Technology Data Exchange (ETDEWEB)

Fatigue tests were accomplished with a series of specimens doped with trace elements of a hardened Fe-Ni-Cr alloy, cast and hardened with intermetallic phases for determining the influence of these elements on the high temperature strength properties. The results of extensive fatigue tests show that even small contents of Te, Bi, Se, Pb, Tl and Zn considerably influence the life and creep processes especially after longer running periods, when added individually or combinedly. In contrast to this, the fatigue ductility is reduced by trace element additions even with short running periods. The order in which the metallic trace elements influence the fatigue properties nearly correlates with earlier work concerning Ni- and Co-superalloys. (orig.)

1993-01-01

210

Spectroscopy of {sup 25}Al and {sup 26,27,28}P using high-energy stripping reactions  

Science.gov (United States)

We report here results of an application of single-nucleon stripping reactions at high energies (65 MeV/u) in inverse kinematics to obtain spectroscopic factors. From measurements of the partial cross-sections for ground and excited states in residual nuclei formed in one-proton stripping reactions, single particle orbits and occupancies of light nuclei have been studied in the s-d shell. Single proton stripping cross-sections of {sup 25}Al and {sup 26,27,28}P on a Be target have been measured using the S800 spectrograph and the NaI(Tl) array at the NSCL. These results indicate that this technique may provide a general tool for the intermediate energy range analogous to transfer (pick-up) reactions at low-energy.

1998-12-21

211

Spectroscopy of "2"5Al and "2"6","2"7","2"8P using high-energy stripping reactions  

International Nuclear Information System (INIS)

We report here results of an application of single-nucleon stripping reactions at high energies (65 MeV/u) in inverse kinematics to obtain spectroscopic factors. From measurements of the partial cross-sections for ground and excited states in residual nuclei formed in one-proton stripping reactions, single particle orbits and occupancies of light nuclei have been studied in the s-d shell. Single proton stripping cross-sections of "2"5Al and "2"6","2"7","2"8P on a Be target have been measured using the S800 spectrograph and the NaI(Tl) array at the NSCL. These results indicate that this technique may provide a general tool for the intermediate energy range analogous to transfer (pick-up) reactions at low-energy.

1998-12-21

212

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

213

Practical superconductor development for electrical power applications  

Energy Technology Data Exchange (ETDEWEB)

Development of useful high-critical-temperature (high-{Tc}) superconductors requires synthesis of superconducting compounds; fabrication of wires, tapes, and films from these compounds; production of composite structures that incorporate stabilizers or insulators; and design and testing of efficient components. This report describes technical progress of research and development efforts aimed at producing superconducting components based on the Y-Ba-Cu, Bi-Sr-Ca-Cu, Bi-Pb-Sr-Ca-Cu, and Tl-Ba-Ca-Cu oxides systems. Topics discussed are synthesis and heat treatment of high-{Tc} superconductors, formation of monolithic and composite wires and tapes, superconductor/metal connectors, characterization of structures and superconducting and mechanical properties, and fabrication and properties of thin films. Collaborations with industry and academia are also documented. 10 figs.

1991-10-01

214

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

215

Luminescence dating  

International Nuclear Information System (INIS)

The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

216

Image diagnosis of parathyroid glands in chronic renal failure  

Energy Technology Data Exchange (ETDEWEB)

Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.

1983-07-01

217

Frequency mixing crystal  

Energy Technology Data Exchange (ETDEWEB)

In a laser system for converting infrared laser light waves to visible light comprising a source of infrared laser light waves and means of harmoic generation associated therewith for production of light waves at integral multiples of the frequency of the original wave, the improvement of said means of harmonic generation comprising a crystal having the chemical formula X.sub.2 Y(NO.sub.3).sub.5 .multidot.2 nZ.sub.2 o wherein X is selected from the group consisting of Li, Na, K, Rb, Cs, and Tl; Y is selected from the group consisting of Sc, Y, La, Ce, Nd, Pr, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Al, Ga, and In; Z is selected from the group consisting of H and D; and n ranges from 0 to 4.

1992-01-01

218

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

219

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

220

Luminescent unit computerization to research spectral characteristics of fine film alkali halide crystal  

International Nuclear Information System (INIS)

The fundamental optical absorption of ion crystals characterizes the creation of different free low energetic electronic excitation (the excitons and electron-hole pairs), but their straight registration is not possible because of incommensurable big absorption factor of alkali halide monocrystals. So to registration the spectrums of alkali halide monocrystal very fine layers are necessary. We have received fine films of Nal and KCl in system of KCl-Nal-KCl, KCl-KI-KCl on the base of universal vacuum post VUP-4, VUP-5 by thermal evaporation. A unique spectral unit has been created For this on the basic the SDL-2 complex. Complex consists of radiator, systems of condensers, monochromators MDR-12 and MDR-23, receivers of radiation, controller by unit. Connect and control of monochromators by means of IBM-compatible computer has been created. Kinematics schemes of monochromators provide consequent removing on output slot of monochromatic radiation in operating range of each diffraction ...

221

Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama. Wilsonville ACL R and D Facility material balance procedure. Topical Report No. 11  

Science.gov (United States)

Prior to 1978, the Wilsonville Advanced Coal Liquefaction facility material balance surrounded only the thermal liquefaction unit and involved analyses of only the slurry stream and individual gas streams. The distillate solvent yield was determined by difference. Subsequently, several modifications and additional process units were introduced to this single unit system. With the inclusion of the deashing unit in 1978 and the catalytic hydrogenation unit in 1981, the process has evolved into a sophisticated two-stage coal liquefaction process and has the potential for various modes of integration. This report presents an elemental balancing procedure and a simplified presentation format that is sufficiently flexible to meet current and future needs. The development of the elemental balancing technique and the relevant computer programs to handle the calculations have been addressed. This will be useful in modelling individual unit performance as well as determining the impact of each ...

1984-09-01

222

Thallium-technetium subtraction parathyroid imaging in patients having previous parathyroid surgery  

International Nuclear Information System (INIS)

Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck exploration, all had PT pathology accurately localized by preoperative scanning (7=single adenoma, 2=single hyperplastic gland, 1=two hyperplastic ...

1985-06-02

223

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear relationship exists between ...

1985-06-02

224

Phosphor plasters of CaSO{sub 4}:Dy on the courtyard wall of Djehuty's tomb (Luxor, Egypt)  

Energy Technology Data Exchange (ETDEWEB)

The X-ray diffraction (XRD) and environmental scanning electron microscopy (ESEM) analyses of plasters collected from the courtyard walls of Djehuty's tomb show anhydrite, calcite, dolomite, quartz, alkali feldspars and accessorial amounts of halite and illite. The external outer bed is mainly composed by anhydrite, since the original hydrous phases of gypsum plaster were desiccated during thirty centuries in the dry land environment of the Luxor area, under low relative humidity and high temperatures. The luminescence analyses by thermoluminescence (TL) and cathodoluminescence (CL) demonstrate as one plaster sample (m8), i.e., 95% anhydrite, displays a gigantic TL emission of 33 555 a.u. and a SEM/CL emission of 2319 a.u. maxima peak. The spectra CL also exhibits a 484 nm peak attributable to the classic {sup 4}F{sub 9/2}{yields}{sup 6}H{sub 15/2} transition circa 490 nm of Dy{sup 3+} and a 573 nm emission of Dy{sup 3+} masked in a ...

2008-02-15

225

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, ...

2008-05-22

226

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed CT images. The a-Se ...

2004-12-07

227

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built and tested. The results of these test, ...

2004-10-13

228

The magnetic spectrometer PAMELA for the study of cosmic antimatter in space  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.

1995-09-01

229

Synthesis of novel high-voltage cathode material LiCoPO{sub 4} via rheological phase method  

Energy Technology Data Exchange (ETDEWEB)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should be ascribed to the better crystallized ...

2010-07-23

230

Synthesis of novel high-voltage cathode material LiCoPO4 via rheological phase method  

International Nuclear Information System (INIS)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to the better crystallized rheological phase ...

2010-07-23

231

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider causes of the increases of ...

2000-05-01

232

Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions  

International Nuclear Information System (INIS)

The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical model predictions and non-statistical ...

233

Resent development by the use of neutron induced nuclear reaction  

International Nuclear Information System (INIS)

When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University lead slowing-down ...

1992-01-01

234

Recent neutron scattering work at the University of Lowell  

International Nuclear Information System (INIS)

Neutron elastic and inelastic scattering cross sections of _2_3_8U and _2_3_2Th have been measured at the University of Lowell for states below 1.8 MeV. A time-of-flight (TOF) spectrometer was used. The disc-shaped scatterer was oriented to optimize energy resolutions for 200-to-500-keV neutrons. Neutrons were obtained via the _7Li(p,n)_7Be reaction. Targets were prepared by in-situ evaporation of Li onto a Ta backing. During the evaporation, the target thickness was monitored using a 5-m-flight-path TOF spectrometer; a typical target had a neutron thickness from 8 to 10 keV for Esub(p) = 2.25.MeV. Spectra were analyzed using the unfolding code TINA; standard peak shapes were obtained from codes LAGUE and LAPA. Results obtained will be presented.

1981-11-23

235

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1992-01-01

236

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1991-10-01

237

Matrix-assisted laser desorption fourier transform mass spectrometry for biological compounds  

Science.gov (United States)

The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted technique. We have ...

1990-01-01

238

High Throughput Screening for the Discovery of More Efficient Catalysts for Emissions Control  

Energy Technology Data Exchange (ETDEWEB)

High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing nozzle and a quadrupolar mass ...

2004-03-31

239

Electron momentum spectroscopy of H_2 and D_2: Ionization to ground and excited final states  

International Nuclear Information System (INIS)

The symmetric noncoplanar (e,2e) cross sections (momentum profiles) of H_2 and D_2 for the transitions to the 2p#sigma#_u and 2s#sigma#_g excited ion states have been measured, relative to the ground-state ion transition, using a high-sensitivity multichannel momentum-dispersive electron momentum spectrometer (EMS) at an impact energy of 1200 eV. Newly calculated plane-wave impulse approximation (PWIA) cross sections, based on a full-configuration-interaction H_2 wave function, are compared to the experimental results. These calculations are in better agreement with the experimental results for the transition to the 2s#sigma#_g ion state than the earlier theoretical work of Liu and Smith, Jr. [Phys. Rev. A 31, 3003 (1985)] which has been found to be in error. Nevertheless, significant discrepancies between the relative experimental and theoretical cross sections are observed for the transitions to excited ion states, suggesting a failure of the PWIA description of ...

240

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

Energy Technology Data Exchange (ETDEWEB)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of [Delta][epsilon] = 1.3 [mu]eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T[sub m] (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T[sub m]. Quasielastic broadening in the spectrum at Q = 0.082 A[sup -1] is observed only above 210degC, which is 75degC higher than the T[sub m]. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 [mu]eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

1992-06-01

241

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

International Nuclear Information System (INIS)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of #DELTA##epsilon# = 1.3 #mu#eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T_m (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T_m. Quasielastic broadening in the spectrum at Q = 0.082 A"-"1 is observed only above 210degC, which is 75degC higher than the T_m. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 #mu#eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

242

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the Galactic Center. (author)

2004-12-15

243

Atomic beam spectrometer using a LiF analyzer crystal  

International Nuclear Information System (INIS)

An energy analyzer has been constructed and operated in UHV for the purpose of analyzing the energy of neutral atoms scattered from solid surfaces. The analyzer consists of a LiF single crystal located at an angle close to the normal to the sample crystal so that the diffraction pattern obtained by scanning the LiF crystal yields the energy of the scattered atoms. Two designs which have been used are described. The temperature of both sample and analyzer crystal is near 20 K and once cleaned they can be maintained in the state of initial preparation for many weeks. The sample was a (001) Cu surface in this case. Such an energy analyzer can only be used, in most cases, for He atom scattering although Ne atoms could be used if the scattered intensities were adequate. The detector developed in this study is able to detect about 2 x 10"5 atoms/s. The resolution of the spectrometer depends on the incident energy of the atom and is about 1 meV at an incident energy of 23 ...

1978-01-01

244

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative ...

245

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...

2000-03-21

246

Use of a new time of flight aerosol mass spectrometer for ground and airborne measurements of biogenically produced organic aerosols  

Environmental Research Database

DescriptionChamber studies have shown that biogenic organic compounds, including isoprene, are capable of producing secondary organic aerosol in significant quantities. This is surprising as isoprene and its photo-oxidation products have relatively high vapour pressures. However, it is very important as isoprene has the largest global emissions flux of any biogenic hydrocarbon, most of which is in the tropics. Despite this, secondary organic aerosol has been poorly studied in tropical regions with only [continued...

247

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

248

Spectroscopy of neutron-rich Fe isotopes populated in the "6"4Ni+"2"3"8U reaction  

International Nuclear Information System (INIS)

The neutron-rich Fe isotopes from A=61 to 66 were studied through multinucleon transfer reactions by bombarding a "2"3"8U target with a 400 MeV "6"4Ni beam. Unambiguous identification of prompt #gamma# rays belonging to each nucleus was achieved using coincidence relationships with the ions detected in a high-acceptance magnetic spectrometer. The new data extend our knowledge of the level structure of Fe isotopes, which is discussed in terms of the systematics of the region and compared with large-scale shell-model calculations.

2007-09-01

249

Spectra of positrons and electrons emitted in "8"8Y decay  

International Nuclear Information System (INIS)

The "8"8Y decay has been studied with the aim to discover emission of monohromatic positrons (MP). The "8"8Sr(d,2N) reaction was used for production of "8"8Y (#beta#"+, Tsub(1/2)=106.6 days) nuclides. The prismatic beta spectrometer has been used to measure spectra of electrons and positrons. No MPs have been found. The resulting upper bound for their emission rate turned out to be lower than theoretically expected one.

250

Soil gamma ray spectrometry of the Buquira river basin, SP, Brazil; Gamametria de solos da bacia do rio Buquira, SP, Brazil  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactivity found in rocks and its evaluation been frequently used for studies of environmental geochemistry, particularly those of detection and control of pollutants and the consequent changes in environment after antropic interferences. In this work natural radioactivity in forty nine soil samples in the basin of Buquira river, at the Northeast region of Sao Paulo State, has been analysed and measured with a Ge-HP gamma ray spectrometer. A table with the most relevant results found in rocks is shown and discussed. (author)

2002-12-01

251

Search for K_S K_S in J/psi and psi(2S) decays  

CERN Document Server

The CP violating processes J/psi-->K_S K_S and psi(2S)-->K_S K_S are searched for using samples of 58 million J/psi and 14 million psi(2S) events collected with the Beijing Spectrometer at the Beijing Electron Positron Collider. No signal is observed, and upper limits on the decay branching ratios are determined to be BR(J/psi-->K_S K_S) K_S K_S) < 4.6x10^{-6} at the 95% confidence level.

2004-01-01

252

Remote sensing of the atmosphere by resonance Raman LIDAR  

Energy Technology Data Exchange (ETDEWEB)

When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.

1994-12-01

253

Refractometry of organosilica microspheres  

CERN Document Server

The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard laboratory spectrometer. The second method relies on the measurable trapping potential of these beads in the focused light beam (laser tweezers). Polystyrene beads were used to test these methods, and the determined dispersion curves of refractive index values have been found accurate. The refractive index of organosilica beads has been determined to range from 1.60-1.51 over the wavelength range of 300-1100 nm.

2007-01-01

254

Radon grab sampling in water by means of radon transfer in activated charcoal collectors  

Energy Technology Data Exchange (ETDEWEB)

The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.

1999-08-01

255

Quasi-elastic electron scattering by GaAs surface  

International Nuclear Information System (INIS)

Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).

1994-03-20

256

Proton and deuteron spin structure function measurements in the resonance region  

Energy Technology Data Exchange (ETDEWEB)

The RSS collaboration has measured the spin structure functions of the proton and the deuteron at Jefferson Lab using the Hall C HMS spectrometer, a polarized electron beam and a polarized solid target. The asymmetries A and A were measured in the region of the nucleon resonances (0.82 GeV < W < 1.98 GeV) at an average four momentum transfer of Q2 = 1.3 GeV2. The extracted spin structure functions and their kinematic dependence will make a significant contribution in the study of higher-twist effects and polarized duality tests. A description of the experiment and the latest findings of the analysis will be presented.

2003-07-01

257

Production of cumulative pions and kaons  

International Nuclear Information System (INIS)

#pi#"#+-# and K"#+-# cumulative production in pA #-># #pi#"#+-#+x and pA #-># K"#+-#+x reactions at 10.14 GeV proton beam energy on nuclei (Be-Ta) was invesigated. Measurements were conducted using FAS-1 focusing hadron spectrometer. Invariant cross sections of #pi#"#+-# and K"#+-# cumulative production, values of ratio of this cross sections, dependences of production cross sections for pions and kaons on cumulative number and mass number of nucleus target, as well as on transverse momentum are measured. Difference of cumulative meson spectra occurring in different nuclei fragmentation is discussed in terms of flucton model. 17 refs.; 14 figs.

1988-06-14

258

Observation of p pbar pi^0 and p pbar eta in psi' decays  

CERN Document Server

The processes psi'-->p pbar pi^0 and psi'-->p pbar eta are studied using a sample of 14 million psi' decays collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider. The branching fraction of psi'-->p pbar pi^0 is measured with improved precision as (13.2\\pm 1.0\\pm 1.5)\\times 10^{-5}, and psi'-->p pbar eta is observed for the first time with a branching fraction of (5.8\\pm 1.1\\pm 0.7)\\times 10^{-5}, where the first errors are statistical and the second ones are systematic.

2005-01-01

259

Near-threshold production of {omega}-mesons in the pn{yields}d{omega} reaction  

Energy Technology Data Exchange (ETDEWEB)

The first measurement of the pn{yields}d{omega} total cross-section has been achieved at mean excess energies Q{approx}28 and 57 MeV by using a deuterium cluster-jet target. The momentum of the fast deuteron was measured in the ANKE spectrometer at COSY-Juelich and that of the slow ''spectator'' proton (p{sub sp}) from the pd{yields}p{sub sp}d{omega} reaction in a silicon telescope placed close to the target. The cross-sections lie above those measured for pp{yields}pp{omega} but seem to be below theoretical predictions. (orig.)

2004-09-01

260

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

261

Measurement of cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight  

CERN Document Server

The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1-4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect of charge sign dependent drift in the solar modulation.

2008-01-01

262

Low-energy fission of nuclei lighter than Hg  

International Nuclear Information System (INIS)

The mass and energy distributions for low-energy p- and alpha-particle induced fission of "1"8"7","1"8"8Ir and "1"9"5Au and "3He-induced fission of sufficiently heated "1"8"8Ir and "1"9"4Au have been measured with use of fast spectrometer of complementary fragments. From Au to Ir, the shape of the mass distributions undergoes substantial changes related to specific dependence of the saddle shell corrections on A and Z fissioning nuclei. The results are compared with theoretical predictions.

263

Level structure of the doubly-odd /sup 242/Am nucleus  

Energy Technology Data Exchange (ETDEWEB)

The level structure of the doubly-odd /sup 242/Am nucleus was investigated by means of thermal-neutron-capture gamma-ray and conversion electron spectroscopy. Pair, curved-crystal, and ..beta.. spectrometers were used. The data from these measurements, combined with previous direct reaction results, permit us to establish a detailed level scheme including six new well-developed bands. Our experimental results are interpreted in the framework of the Nilsson model. Precise Gallagher-Moszkowski splittings and Newby odd-even shifts extracted from the data are compared with theoretical calculations.

1988-06-01

264

Laser photoelectron spectroscopy of ions. Progress report, August 1, 1982-July 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.

1983-03-01

265

Improved measurement of the branching ratio of J/psi-->K_S K_L  

CERN Document Server

The branching ratio of J/psi-->K_S K_L is measured with improved precision to be B(J/psi-->K_S K_L) = (1.82\\pm 0.04\\pm 0.13)\\times 10^{-4}. using J/psi data collected with the Beijing Spectrometer (BESII) at the Beijing Electron-Positron Collider. This result is used to test the perturbative QCD ``12%'' rule between psi(2S) and J/psi decays and to investigate the relative phase between the three-gluon and one-photon annihilation amplitudes in J/psi decays.

2004-01-01

266

Failure analysis on a ruptured petrochemical pipe  

Energy Technology Data Exchange (ETDEWEB)

The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

2010-08-15

267

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

268

Electromagnetic decay properties of multiparticle-hole states in neutron deficient Mo and Tc isotopes  

Energy Technology Data Exchange (ETDEWEB)

Neutron deficient nuclei with mass numbers A {approx} 90 and 40 {<=} Z {<=} 44 have been studied making use of the Osiris and Nordball spectrometers. The high spin states of these nuclei and their electromagnetic decay properties are compared to shell model calculations based on the core {sup 88}Sr and using different parametrizations of the residual interaction. The dependence of the mean square deviations of experimental and theoretical level energies, branching ratios, and transition probabilities on the neutron numbers N = 46-50 and the validity of seniority as a good quantum number are discussed. (orig.).

1995-12-31

269

Effect of the size of an artificial neural network used as pattern identifier  

Energy Technology Data Exchange (ETDEWEB)

A novel way to extract relevant parameters associated with the outgoing ions from nuclear reactions, obtained by digitizing the signals provided by a Bragg curve spectrometer (BCS) is presented. This allowed the implementation of a more thorough pulse-shape analysis. Due to the complexity of this task, it was required to take advantage of new and more powerful computational paradigms. This was fulfilled using a back-propagation artificial neural network (ANN) as a pattern identifier. Over training of ANNs is a common problem during the training stage. In the performance of the ANN there is a compromise between its size and the size of the training set. Here, this effect will be illustrated in relation to the problem of Bragg Curve (BC) identification. (Author)

2003-07-01

270

COBE confounds the cosmologists  

Energy Technology Data Exchange (ETDEWEB)

The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.

1990-03-01

271

Basic Design Report of DC-TOF Inelastic Neutron Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.

2006-04-15

272

A preliminary design for a one GHz NMR spectrometer magnet  

International Nuclear Information System (INIS)

The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.

1993-09-20

273

State of the Art Laser Induced Breakdown Spectroscopy  

International Nuclear Information System (INIS)

Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life quality are increased, a detailed analysis on the environmental ...

274

Experimental Study of Hypernuclei Electroproduction by High Precision Spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the analysis of CH{sub 2}, ...

2009-12-01

275

Ultratrace determination in high-purity molybdenum and tungsten with ion chromatographic trace-matrix-separation. Pt. 1; Selection and optimization of the separation step. Ultraspurenanalytik in hochreinem Molybdaen und Wolfram mit ionenchromatographischer Spuren-Matrix-Trennung. Tl. 1; Auswahl und Optimierung des Trennschritts  

Energy Technology Data Exchange (ETDEWEB)

Known trace-matrix-separation and enrichment procedures for the refractory metals Mo and W use very time-consuming batch-techniques. This paper presents the application of a quasicontinuous liquid chromatographic (LC) technique as a step towards automated ultratrace separation. The anionic peroxo complexes from Mo(VI) and W(VI) are used for the trace-matrix-separation. Optimization of the peroxide concentration permits a complete removal of all cationic analyte traces on the HPLC-suitable cation exchanger Nucleosil SA. The high chromato-graphic efficiency also allows a direct ion chromatographic separation of the removed traces. This leads to conclusions about the contribution of the analyte traces on the trace-matrix-separation column and the limits of determination. (author). 13 refs.; 12 figs.; 5 tabs.

1991-11-20

276

Ternary oxide nanostructures and methods of making same  

Energy Technology Data Exchange (ETDEWEB)

A single crystalline ternary nanostructure having the formula A.sub.xB.sub.yO.sub.z, wherein x ranges from 0.25 to 24, and y ranges from 1.5 to 40, and wherein A and B are independently selected from the group consisting of Ag, Al, As, Au, B, Ba, Br, Ca, Cd, Ce, Cl, Cm, Co, Cr, Cs, Cu, Dy, Er, Eu, F, Fe, Ga, Gd, Ge, Hf, Ho, I, In, Ir, K, La, Li, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, Os, P, Pb, Pd, Pr, Pt, Rb, Re, Rh, Ru, S, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Tc, Te, Ti, Tl, Tm, U, V, W, Y, Yb, and Zn, wherein the nanostructure is at least 95% free of defects and/or dislocations.

2009-09-08

277

Sodium to sodium carbonate conversion process  

Energy Technology Data Exchange (ETDEWEB)

A method is described for converting radioactive alkali metal into a low level disposable solid waste material. The radioactive alkali metal is atomized and introduced into an aqueous caustic solution having caustic present in the range of from about 20 wt % to about 70 wt % to convert the radioactive alkali metal to a radioactive alkali metal hydroxide. The aqueous caustic containing radioactive alkali metal hydroxide and CO{sub 2} are introduced into a thin film evaporator with the CO{sub 2} present in an amount greater than required to convert the alkali metal hydroxide to a radioactive alkali metal carbonate, and thereafter the radioactive alkali metal carbonate is separated from the thin film evaporator as a dry powder. Hydroxide solutions containing toxic metal hydroxide including one or more metal ions of Sb, As, Ba, Be, Cd, Cr, Pb, Hg, Ni, Se, Ag and Tl can be converted into a low level non-hazardous waste using the thin film evaporator of the invention. 3 ...

1997-10-14

278

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

279

Radiation methods in research of ancient monuments  

Energy Technology Data Exchange (ETDEWEB)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray fluorescence analysis has ...

2000-11-15

280

Radiation methods in research of ancient monuments  

International Nuclear Information System (INIS)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray fluorescence analysis has been chosen as the ...

2000-11-15

281

Quantification of "2"3"5U and "2"3"8U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional ...

2011-06-01

282

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron activation analysis and analyses of natural ...

1994-09-01

283

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the theoretical background and ...

2010-01-01

284

NOAA National Status and Trends Program Tenth Round Intercomparison for Trace Metals in Marine Sediments and Biological Tissues. National Status and Trends Program for marine environmental quality: Technical memo  

Energy Technology Data Exchange (ETDEWEB)

A total of forty participants were included in the exercise, including NOAA, USEPA, state, Australian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant: a contaminated marine sediment from the vicinity of New York Bay and a freeze dried mussel (Mytilus edulis) from Charlottenlund, Denmark. Laboratories were also asked to analyze two certified reference materials NIST SRM 1566a, and NRC BCSS-1. The elements to be determined were Al, Cr, Fe, Ni, Cu, Zn, As, Se, Ag, Cd, Sn, Hg, and Pb for both matrices, plus Be, Si, Mn, Sb, and Tl for the sediments. An accepted mean and confidence interval were calculated for each analyte in the two unknown samples. Laboratory biases were identified and an overall rating of superior, good, fair or others was assigned to each laboratory.

1996-11-01

285

NMR study of Ba2"+ ion motion in one-dimensional ionic conductor with hollandite-type structure  

International Nuclear Information System (INIS)

Ionic motion of a divalent cation, Ba"2"+, in a single crystal of Ba-Al-priderite was studied using "2"7Al as an NMR probe. Several pairs of satellite peaks due to electric quadrupole interaction were observed superposed on broad satellite tails on both sides of the main peak of "2"7Al. These peak pairs indicate the existence of some stable three-dimensional configurations of Ba"2"+ ions in the structure, and the broad shoulders show a random substitution of Al"3"+ for Ti"4"+ sites. The temperature dependence of the spin-lattice relaxation time T"*_l measured in the temperature range from 161 to 1176 K was analyzed by a curve fitting method on the assumption that there are two types of Ba"2"+ ions. An activation energy of 0.47 eV was obtained for the motion of Ba"2"+ ions which are easy to move, and a broad distribution of activation energies spread over a range from 0.95 to 2.45 eV was obtained for the motion of Ba"2"+ ions which form a three-dimensional honeycomb ...

286

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

287

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

288

Luminescence of CaGa2Se4:Eu crystals  

International Nuclear Information System (INIS)

We have studied photoluminescence and thermoluminescence (PL and TL) in CaGa2Se4:Eu crystals in the temperature range 77-400 K. We have established that broadband photoluminescence with maximum at 571 nm is due to intracenter transitions 4f6 5d-4f7 (8S7/2) of the Eu2+ ions. From the temperature dependence of the intensity (log I-103/T), we determined the activation energy (Ea = 0.04 eV) for thermal quenching of photoluminescence. From the thermoluminescence spectra, we determined the trap depths: 0.31, 0.44, 0.53, 0.59 eV. The lifetime of the excited state 4f6 5d of the Eu2+ ions in the CaGa2Se4 crystal found from the luminescence decay kinetics is 3.8 ?sec. (authors)

289

IAEA RESEARCH CONTRACTS SECOND ANNUAL REPORT. Technical Reports Series No. 9  

Science.gov (United States)

Summaries are presented for those research contracts which expired between December 31, 1960 and December 31, 1981. Topics covered include: factors controlling distribution of fission products in biosphere, non-destructive methods of evaluating the U/sup 235/ and Pu content of irradiated fuel elements, studies of contamination in local marine resources, tracer studies of anemia, non-destructive analysis of irradiated fuel elements using a flux integrating monitor, mechanism of proteolysis of I/sup 131/-labeled fibrinogen, radiosensitivity of spermatogonia of Drosophila melel elements by gamma scanning, uptake and loss of radioactive material by marine bacteria, factors which influence the movement of radioactive strontium from soils to plants, biological concentration of fission products in mollusks from water, decay scheme of Tl/sup 210/, calcium balance in metabolic bone disease, development of radioactive drugs with special reference ...

1962-01-01

290

Comparative action spectrum for ultraviolet light killing of mouse melanocytes from different genetic coat color backgrounds  

International Nuclear Information System (INIS)

The photobiology of mouse melanocyte lines with different pigment genotypes was studied by measuring colony-forming ability after irradiation. The cell lines were wild-type black (melan-a) and the mutants brown (melan-b) and albino (melan-c). Four lamps emitting various UV wavelengths were used. These were germicidal (UVC, 200-280 nm), 82.3% output at 254 nm, TL01 (UVB, 280-320 nm), 64.2% at 310-311 nm, FS20, broadband with peak output at 312 nm and Alisun-S (UVA, 320-400 nm), broadband with peak output at 350-354 nm. Appropriate filtration reduced the contaminating UVC to nonlethal levels for the longer waverange lamps. It is clear from these studies that, in pigment cells, monochromatic results cannot predict polychromatic responses and that cell death from solar irradiations is a complex phenomenon that depends on more than DNA damage. (author).

1997-01-01

291

ZnO microsheet modified TiO2 nanoparticle composite films for dye-sensitized solar cells  

British Library Electronic Table of Contents (United Kingdom)

Randomly oriented ZnO microsheets were successfully self-assembled on TiO2 nanoparticle (TN) film to act as the scattering layer via a cathodic electrodeposition process. The light scattering properties of ZnO microsheets were studied by UV-Vis spectrometer in the 400?800 nm wavelength range. It was found that ZnO microsheets exhibited excellent ability to scatter the incident light for ZnO microsheet-TiO2 nanoparticle (ZT) composite films. The results showed that dye-sensitized solar cells (DSSCs) fabricated with ZT composite films showed higher short-circuit density (J sc) and conversion efficiency than TN-based DSSCs, due to the light scattering properties of ZnO microsheets.

2010-01-01

292

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.

1984-03-01

293

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

International Nuclear Information System (INIS)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).

294

Thermal electron attachment and detachment, and electron affinities  

International Nuclear Information System (INIS)

Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).

1994-03-20

295

The search for decaying Dark Matter  

CERN Document Server

We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the formation of the cosmic web are different from ...

2009-01-01

296

The microscopic dynamics of condensed parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

We have measured the almost-pure incoherent scattering function of liquid and solid parahydrogen, using inelastic neutron scattering. The experiments were carried out on TOSCA, a time-of-flight, inverse-geometry, crystal-analyzer spectrometer, operating on the pulsed neutron source at ISIS (UK). The experiments have been planned taking advantage of the intrinsic incoherence introduced in the scattering process by the rotational transitions. The measured double-differential cross section gives a direct experimental access to the microscopic dynamics of condensed hydrogen. From the high-energy region of the spectrum, where the impulse approximation for the center of mass motion applies, we have been able to extract the translational mean kinetic energy. In the low-energy region, using the Gaussian approximation, we compare the experimental data in the liquid phase with the results of a model for the velocity autocorrelation function. The results are encouraging, but ...

2002-07-01

297

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

298

Ternary and quaternary fission  

Energy Technology Data Exchange (ETDEWEB)

In a systematic survey of ternary fission induced by thermal neutrons at the Lohengrin spectrometer of the ILL/Grenoble, the target nucleus {sup 249}Cf has recently been added to the list of actinides under study. Special emphasis was put on the search for the heaviest ternary particles. At the limit of detection (some 10{sup -9} per fission), the heaviest isotopes observed for {sup 249}Cf(n{sub th},f) are {sup 37}Si and {sup 37}S. Another rare process in low energy fission is quaternary fission. Here two light charged particles accompany the main fragments. The reaction {sup 233} U(n,f) has been studied at a cold neutron beam of the ILL. Two processess have to be disentangled: simultaneous and sequential quaternary fission. In the simultaneous decay the most probable combination of particles is ({alpha} + {alpha}) with a yield of {approx}10{sup -7}/fission.

2004-04-05

299

Survival of gas phase amino acids and nucleobases in space radiation conditions  

CERN Document Server

We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a stable cation.

2008-01-01

300

Study of the reaction {sup 22}Ne(131 MeV) + {sup 208}Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up  

Energy Technology Data Exchange (ETDEWEB)

An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.

2005-07-01

301

Study of duality in the transition region at Jlab  

Energy Technology Data Exchange (ETDEWEB)

Inclusive double spin asymmetries obtained by scattering polarized electrons off polarized protons and deuterons have been analyzed to address the issue of quark-hadron duality in the polarized spin structure functions g^p_1 and g^d_1. A polarized electron beam, solid polarized NH_3 and ND_3 targets and the CEBAF Large Acceptance Spectrometer (CLAS) in Hall B were used to collect the data. The resulting g^p_1 and g^d_1 were averaged over the nucleon resonance energy region (M < W < 2.00 GeV), and three lowest lying resonances individually for tests of global and local duality.

2007-01-01

302

Spectroscopy of neutron-rich {sup 59-63}Mn isotopes  

Science.gov (United States)

The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a {sup 238}U target with a beam of {sup 70}Zn at an energy of E{sub lab}=460 MeV. Prompt {gamma} rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.

2008-08-15

303

Spectroscopy of neutron-rich "5"9"-"6"3Mn isotopes  

International Nuclear Information System (INIS)

The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a "2"3"8U target with a beam of "7"0Zn at an energy of E_l_a_b=460 MeV. Prompt #gamma# rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.

2008-08-01

304

Spectroscopic measurement of the Doppler broadening region of He II line emission of DT plasmas using impurity pellets  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of spectroscopic measurement of the velocity distribution of alpha particle using the ablation cloud of a lithium or boron pellet was tested in the DT experiment of TFTR. The measurement was performed using a 10-channel narrow-band filtered spectrometer in the wavelength covering the 3.5 MeV alpha particle Doppler broadening region of the He II 468.6 nm line and its vicinity. The spectra from a lithium pellet consists of the continuum bremsstrahlung background, lithium line emissions and possibly a 468.6 nm helium line. However, no clear evidence of alpha particles was observed, even when boron pellets were injected. (orig.) 4 refs.

1997-03-01

305

Silicate emission in Orion  

CERN Document Server

We present mid-infrared spectro-imagery and high-resolution spectroscopy ofthe Orion bar and of a region in the Orion nebula. These observations have beenobtained in the Guaranteed Time with the Circular Variable Filters of the ISOcamera (CAM-CVF) and with the Short Wavelength Spectrometer (SWS), on board theEuropean Infrared Space Observatory (ISO). Our data shows emission fromamorphous silicate grains from the entire HII region and around the isolatedO9.5V star Theta2 Ori A. The observed spectra can be reproduced by a mixture ofinterstellar silicate and carbon grains heated by the radiation of the hotstars present in the region. Crystalline silicates are also observed in theOrion nebula and suspected around Theta2 Ori A. They are probably ofinterstellar origin. The ionization structure and the distribution of thecarriers of the Aromatic Infrared Bands (AIBs) are briefly discussed on thebasis of the ISO observations.

2000-01-01

306

Retention of ring structure in cyclopentane and alkylcyclopentane molecular cations  

Energy Technology Data Exchange (ETDEWEB)

All measurements were made with the NBS high-pressure photoionization mass spectrometer. The fractional of C/sub 5/H/sub 10//sup +/ions in a cyclopentane-cyclohexane mixture were determined as a function of pressure in order to define the fraction of the ions which did charge exchange with cyclohexane; i.e. the fraction which remained cyclic after ionization. The data for mixtures of various compositions (2.5 to 10% cyclohexane) are summarized for measurements performed at 10.62 eV: (a) 292K, > 96% cyclic; 347 K, greater than or equal to 94% cyclic; 386 K, 84 +- 4% cyclic; and 412 K, 78 +- 6% cyclic; entropy, enthalpy, and activation energy were determined; 10.49 eV was obtained as the ionization potential of cyclopentane. 1 figure.

1980-01-01

307

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

308

Recent developments at ISOLTRAP towards a relative mass accuracy of exotic nuclei below $10^{-8}$  

CERN Document Server

During the last two years, the performance of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN (Geneva) has been considerably enhanced. Many technical improvements have been completed (i) to access nuclides that are produced in minute quantities of only 100 ions s/sup -1/, (ii) to increase the relative mass accuracy to

2003-01-01

309

Rapid determination of granisetron in human plasma by liquid chromatography coupled to tandem mass spectrometry and its application to bioequivalence study  

British Library Electronic Table of Contents (United Kingdom)

A simple, sensitive and rapid method for analysis of granisetron in human plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and internal standard (IS) were isolated from 100ml plasma samples by liquid-liquid extraction (LLE). A Varian 1200l tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 313.4/138 for granisetron and m/z 270/201 for the IS used for quantitation. The assay exhibited a linear dynamic range of 0.02-20ng/ml for granisetron in human plasma. The lower limit of quantification (LLOQ) was 0.02ng/ml with a relative standard deviati...

2006-01-01

310

Radial velocities, dynamics of stars and nebulosities with GAIA and VLT-GIRAFFE  

CERN Document Server

This document is divided in two parts. The first part deals with the radial velocities (RV) distributions for B-type stars and nebulosities observed with the VLT-GIRAFFE in the Large and Small Magellanic Clouds towards the open clusters NGC2004 and NGC330. Thanks to the resolution of GIRAFFE spectra, we found that the RV distribution for the nebulosities in the LMC is bi-modal. This bi-modality can be interpreted, in term of dynamics, by the expansion of the LMC4 superbubble. The second part deals with the GAIA space mission and the determination of the radial velocities by using Radial Velocity Spectrometer (RVS) spectra. The methods to determine the radial velocities are presented as well as preliminary results on simulated RVS spectra.

2008-01-01

311

Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

312

Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

313

Polarized neutron diffraction study of CePd{sub 3}  

Energy Technology Data Exchange (ETDEWEB)

We have performed polarized neutron diffraction measurements on the intermediate valence compound CePd{sub 3} using the D3 spectrometer at the ILL. The results show that at low temperatures, 1.7 K, as well as at 100 K, the field-induced magnetic amplitudes measured in a field of 4.6 T could be interpreted in terms of two contributions: a 4f-type contribution with a Ce{sup 3+} form factor, and an extra delocalized contribution (relatively narrow in q-extent). In particular, we find that the values of the 4f moment deduced from the extrapolation of the neutron data to Q=0 are systematically lower than the values deduced from bulk magnetization measurements performed on the same sample. This difference can be ascribed to a possible positive polarization of the conduction band which is similar at both temperatures.

2004-07-15

314

Photodegradation of flupentixol in aqueous solution under irradiation at 254nm: Identification of the photoproducts generated  

British Library Electronic Table of Contents (United Kingdom)

After irradiation at 254nm of aqueous solutions of the antipsychotic drug flupentixol, the structures of the photodegradation products were determined by ultra high performance liquid-chromatography linked to mass spectrometry. Fragmentation patterns of the parent ions were established on a hybrid linear ion trap-orbitrap mass spectrometer allowing accurate mass measurements of both parent and daughter ions. This allowed to propose plausible structures for the main photolysis products of flupentixol. A total of nine photoproducts were detected after irradiation of the drug. The main photoproduct is generated following the addition of a hydroxyl group on the double bond adjacent to the thioxanthene ring. Secondary photoproducts were also observed.

2010-01-01

315

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u {sup 86}Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss mesurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parameterization. The resulting prospects for reaching even more neutron-rich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1991-10-01

316

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u sup 86 Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1992-07-01

317

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u "8"6Kr beam  

International Nuclear Information System (INIS)

We have measured production cross-sections of the new neutron-rich isotopes "5"8Ti, "6"1V, "6"3Cr, "6"6Mn, "6"9Fe, "7"1Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u "8"6Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide "7"8Ni, are discussed. (orig.).

318

Neutron inelastic scattering to octupole states in single-closed-shell nuclei  

International Nuclear Information System (INIS)

Differential cross sections for the excitation of the first octupole-vibrational state in the closed-neutron-shell nuclides "8"8Sr and "9"0Zr and in the closed-proton shell-nuclei sup(116,118,120,124)Sn by 11 MeV neutrons are presented. The distorted-wave Born approximation is used to obtain deformation lengths, delta(3"-) for each state. Results are compared with earlier measurements of inelastic proton scattering to the same states. Although limited resolution in the neutron time-of-flight spectrometer complicates the interpretation of the Sn data, the overall conclusion that deltasub(nn')(3"-) approx. deltasub(pp')(3"-) is supported by all of the measurements. (orig.).

319

Moessbauer investigation of the magnetic anisotropy and electronic structure of a metallic glass  

International Nuclear Information System (INIS)

The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).

320

Measurement of attenuation coefficients for bone, muscle, fat and water at 140, 364 and 662keV ?-ray energies  

International Nuclear Information System (INIS)

The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.

2006-11-01

321

Mass measurement of neutron-rich isotopes from [sup 51]Ca to [sup 72]Ni  

Energy Technology Data Exchange (ETDEWEB)

The ground state masses of thirty-nine neutron-rich nuclei from [sup 51]Ca to [sup 72]Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of [sup 68]Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.)

1994-07-01

322

Mass measurement of neutron-rich isotopes from "5"1Ca to "7"2Ni  

International Nuclear Information System (INIS)

The ground state masses of thirty-nine neutron-rich nuclei from "5"1Ca to "7"2Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of "6"8Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.).

323

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

324

Liquid chromatography with ultraviolet and dual parallel mass spectrometric detection for analysis of vitamin D in retail fortified orange juice  

British Library Electronic Table of Contents (United Kingdom)

Samples of vitamin D fortified orange juice obtained from retail food stores were analyzed for vitamin D3 content using a method developed by combining the best features of two AOAC methods. Detection by ultraviolet absorption at 265nm was compared to detection by selected ion monitoring (SIM) using atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Furthermore, an ion trap (IT) mass spectrometer was employed in a 'dual parallel MS' arrangement to simultaneously obtain qualitative APCI-ITMS data. The method was applied to 33 samples of 3 national American orange juice brands and 7 samples of 5 other American brands collected using a statistically designed sampling plan as part of the National Food and Nutrient Analysis Program to provide values for the USDA National Nu...

2011-01-01

325

KLOE-2 experiment at DA$\\Phi$NE upgraded in luminosity  

CERN Document Server

Prospective presentation is given for the experimental program of the KLOE-2 Collaboration, to be performed using the DA$\\Phi$NE $e^+e^-$ collider upgraded in luminosity. Data with the total luminosity of 25 fb$^{-1}$ are aimed to be collected in 3 years. Major modifications of the accelerator and the spectrometer are described. The KLOE-2 physics program contains: CKM unitarity and lepton universality tests, $\\gamma\\gamma$ physics, search for quantum decoherence and testing CPT conservation, low-energy QCD, rare kaon decays, physics of $\\eta$ and $\\eta^\\prime$, structure of low-mass scalars, contribution of vacuum polarization to $(g-2)_{\\mu}$, possible search for WIMP dark matter. In this paper only selected physics subjects are reported.

2011-01-01

326

Joule-Thomson cryogenic cooler with extremely high thermal stability  

Science.gov (United States)

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

1991-06-01

327

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

328

Instrumental neutron activation analysis of copper-molybdenum ores for molybdenum content determination  

International Nuclear Information System (INIS)

An instrumental neutron activation technique of determining molybdenum in ores is based on measuring gamma-activity of the "9"9Mo isotope with the use of planar and coaxial semiconductor spectrometers. A lot consisting of 50 portions, 0.5 g each, is being irradiated for 10 hours by a flow of neutrons with the density of 10"1"2 n/cm"2xsec. On the lot being allowed to stay for 3-4 days, its activity is measured during 1-5 minutes. Monoethalons based upon phenol-formaldehyde resin are used as standards. The sensitivity of the technique is 10"-"4%, reproducibility error being not higher than 10%, efficiency up to 50 portions for a working shift.

329

Indirect Dark Matter Signals  

CERN Document Server

Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. Several signatures, ranging from the positron excess, as observed by HEAT, AMS-01 and PAMELA, the gamma ray excess, as observed by the EGRET spectrometer, the WMAP-haze, and constraints from antiprotons, as observed by CAPRICE, BESS and PAMELA, have been discussed in the literature. Unfortunately, the different signatures all lead to different WIMP masses, indicating that at least some of these interpretations are likely to be incorrect. Here we review them and discuss their relative merits and uncertainties. New x-ray data from ROSAT suggests non-negligible convection in our Galaxy, which leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer space.

2008-01-01

330

High-resolution NMR on /sup 29/Si nuclei in acidic zeolites  

Science.gov (United States)

The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.

1986-12-01

331

High resolution X ray spectroscopy in light antiprotonic atoms  

Energy Technology Data Exchange (ETDEWEB)

At the LEAR facility, CERN, antiprotonic L{alpha} transitions in light elements have been investigated with a focussing crystal spectrometer. The high resolution of the experiment allowed for the first time to resolve in p-barH the 2{sup 3}P{sub 0} state from the close lying states 2{sup 3}P{sub 2}, 2{sup 1}P{sub 1}, and 2{sup 3}P{sub 1}. In p-barD the corresponding transitions were found to be more than an order of magnitude broader. To a large extent the results for p-barH support the meson exchange model.

2000-08-15

332

First observation of psi(2S)-->K_S K_L  

CERN Document Server

The decay psi(2S)-->K_S K_L is observed for the first time using psi(2S) data collected with the Beijing Spectrometer (BESII) at the Beijing Electron Positron Collider (BEPC); the branching ratio is determined to be B(psi(2S)-->K_S K_L) = (5.24\\pm 0.47 \\pm 0.48)\\times 10^{-5}. Compared with J/psi-->K_S K_L, the psi(2S) branching ratio is enhanced relative to the prediction of the perturbative QCD ``12%'' rule. The result, together with the branching ratios of psi(2S) decays to other pseudoscalar meson pairs (\\pi^+\\pi^- and K^+K^-), is used to investigate the relative phase between the three-gluon and the one-photon annihilation amplitudes of psi(2S) decays.

2003-01-01

333

Explosives sensor  

Energy Technology Data Exchange (ETDEWEB)

A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this device's construction and advantages are discussed in ...

1987-01-01

334

Exclusive ?0 electroproduction on transversely polarized protons  

International Nuclear Information System (INIS)

The exclusive electroproduction of ?0 mesons was studied with the HERMES spectrometer at the DESY laboratory by scattering 27.6 GeV positron and electron beams off a transversely polarized hydrogen target. Spin density matrix elements for this process were determined from the measured production- and decay-angle distributions of the produced ?0 mesons. These matrix elements embody information on helicity transfer and the validity of s-channel helicity conservation in the case of a transversely polarized target. From the spin density matrix elements, the leading-twist term in the single-spin asymmetry was calculated separately for longitudinally and transversely polarized ?0 mesons. Neglecting s-channel helicity changing matrix elements, results for the former can be compared to calculations based on generalized parton distributions, which are sensitive to the contribution of the total angular momentum of the quarks to the proton spin.

2009-08-17

335

Elastic and inelastic scattering of "1"4C from medium heavy nuclei  

International Nuclear Information System (INIS)

The elastic and inelastic scattering of "1"4C at 51 MeV from targets of "4"0Ca, "5"6Fe, "6"0Ni, "6"6Zn and "8"8Sr has been measured using a Q3D spectrometer. The "1"4C-nucleus potentials have been derived by optical-model analysis of the observed elastic scattering; the inelastic scattering differential cross sections were interpreted in the distorted-wave Born approximation and also in the coupled-channels approach. The analysis yields "1"4C-nucleus potentials that closely resemble "1"2sup(,)"1"3C and "1"6O potentials. (orig.).

336

Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon  

International Nuclear Information System (INIS)

N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code

2001-12-01

337

Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge  

British Library Electronic Table of Contents (United Kingdom)

The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...

2010-01-01

338

Chemical and morphological characterization of mesoporous material supported copper oxide nanoparticles for potential application  

British Library Electronic Table of Contents (United Kingdom)

SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...

2011-01-01

339

Cavity ringdown spectroscopy with a continuous-wave laser: calculation of coupling efficiency and a new spectrometer design.  

Science.gov (United States)

For the efficient operation of a cavity ringdown spectroscopy (CRDS) system utilized with a continuous-wave (cw) laser, we numerically analyze the coupling efficiency of a cw laser to a ringdown cavity in terms of changes in the scanning rate, the laser linewidth, and the mirror reflectivity. We also demonstrate a new simple design for a CRDS system that can produce a CRDS signal with only a piezoelectric transducer (PZT), without the acousto-optic modulator that is usually adopted to switch off the cw laser beam that enters the cavity. Furthermore, we investigate the feasibility of the cw CRDS technique with a fast-scanning PZT by recording a CRDS spectrum of acetylene overtones. The detection sensitivity that corresponds to the noise-equivalent absorption is found to be approximately 3 x 10(-9)/cm. PMID:18305817

1999-03-20

340

Barium carbonate sediment sampling for inorganic dissolved carbon using isotope mass ratio spectrometer  

International Nuclear Information System (INIS)

This paperwork explain the method of water sampling to obtain the precipitate of BaCO3 solutions that will be used to analyze 13C from field work in Kelana Jaya, Selangor, Langkawi, Kedah and Taiping, Perak. The sampling involves collecting of water samples for groundwater from boreholes and surface water from canal, river, pond and ex-mining pond from several locations at the study sites. This study also elaborates the instruments and chemicals used. The main purpose of this sampling is to obtain the precipitate of BaCO3 for 13C analysis of dissolved inorganic carbon (DIC). A correct sampling method according to standard is very important to ensure an accurate and precise result. With this, the data from the laboratory analysis result can be fully utilized to make the interpretation of the pollutants movement. (Author)

2009-10-06

341

Accelerator mass spectrometry: state of the art  

Energy Technology Data Exchange (ETDEWEB)

Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.

1996-12-31

342

A polarized neutron reflectometry study of the spin glass freezing in a 29 nm thick AuFe film  

Energy Technology Data Exchange (ETDEWEB)

We performed polarized neutron reflectometry (PNR) experiments on a 29 nm thick Au{sub 93}Fe{sub 7} film in a temperature range from 295 K down to 2 K in a vertical magnetic field up to 6 T. These high-field experiments were performed on the C5 spectrometer in Chalk River, Canada, using a split-pair cryomagnet. The magnetization as determined by PNR can be described with a Brillouin function from 295 K down to 50 K assuming the magnetic moment of isolated Fe atoms, i.e. 4{mu}{sub B} per Fe atom. Below 50 K the onset of the spin-glass freezing is observed as a strong deviation from this Brillouin type behavior of isolated atoms.

2007-07-15

343

A novel electrochemical alkylation of aniline with methanol over Zn/Cu salts modified kaolin  

British Library Electronic Table of Contents (United Kingdom)

A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...

2008-01-01

344

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

345

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of the two ...

2010-10-01

346

Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination  

Energy Technology Data Exchange (ETDEWEB)

The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...

2000-07-01

347

Penning trap mass spectrometry of neutron-rich Fe and Co isotopes around N=40 with the LEBIT mass spectrometer  

International Nuclear Information System (INIS)

Penning trap mass spectrometry is presented as a complementary tool to nuclear spectroscopy experiments for the study of nuclear structure in the vicinity of N=40, Z=28. High-precision mass measurements of the "6"3"-"6"6Fe and "6"4"-"6"7Co isotopes have been carried out with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. The newly obtained mass values for "6"6Fe and "6"7Co are presented, together with the previously reported LEBIT mass measurements in this region. In the case of "6"5Fe the existence of a new isomer is reported, and an isomer recently discovered by decay spectroscopy in "6"7Co is confirmed. Relative mass uncertainties as low as 4x10"-"8 are obtained. All mass values are found to be in good agreement with previous experimental results with the exception of "6"4Co, where a 5#sigma# deviation is observed. Using these data the two neutron separation energies S_2_n are calculated. However, the large error bars in the mass values ...

2010-04-01

348

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the ...

1997-05-01

349

Experimental determination of line strengths for selected carbon monoxide and carbon dioxide absorption lines at temperatures between 295 and 1250 K  

Energy Technology Data Exchange (ETDEWEB)

Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO[sub 2] absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the [ital P] branch of the fundamental absorption band (2150--1950 cm[sup [minus]1]) while the CO[sub 2] vibrational-rotational lines were from the far wing of the [ital R] branch of the [nu][sub 3] fundamental band (2395--2380 cm[sup [minus]1]). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO[sub 2]/N[sub 2] gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak ...

1994-11-01

350

Experimental determination of line strengths for selected carbon monoxide and carbon dioxide absorption lines at temperatures between 295 and 1250 K  

International Nuclear Information System (INIS)

Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO_2 absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the P branch of the fundamental absorption band (2150--1950 cm"-"1) while the CO_2 vibrational-rotational lines were from the far wing of the R branch of the #nu#_3 fundamental band (2395--2380 cm"-"1). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO_2/N_2 gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak overlap. Line strength measurements were made from the corrected ...

351

Diagnostics aid for mass spectrometer trouble-shooting  

International Nuclear Information System (INIS)

The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The overall analysis ...

352

Development of a Bragg curve spectrometer (BCS) for fragment spectroscopy from neutron and proton induced reactions  

Energy Technology Data Exchange (ETDEWEB)

Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the saturation property by using {sup 241}Am {alpha} ...

2002-09-01

353

Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region; Determination de la reponse instrumentale du spectrometre INTEGRAL/SPI et application a l'observation des raies gamma de la region des Voiles  

Energy Technology Data Exchange (ETDEWEB)

The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...

2005-01-15

354

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The process is observed to be dominated by the ...

1988-11-01

355

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation measurement capabilities ...

1995-11-01

356

Absence of isoscalar monopole strength in {sup 56}Fe and {sup 58}Ni  

Energy Technology Data Exchange (ETDEWEB)

Measurements with 240 MeV {alpha} particle inelastic scattering with excellent peak/background ratios at small scattering angles including 0{degrees} were made on {sup 56}Fe and {sup 58}Ni using the multipole-dipole-multipole spectrometer at Texas A&M University. Beam was delivered to the spectrometer through a beam analysis system having two bends of 88{degrees} and 87{degrees} respectively. A slit placed after the first 88{degrees} bend was used to define the beam. Slits placed after the second bend (87{degrees}) were used to eliminate slit scattered particles. Comparison of the results of a multiple peak fit to the{sup 58}Ni spectra after continuum subtraction to DWBA calculations revealed about 32% of the E0 EWSR and 58% of the E2 EWSR in the peak, in agreement with previous works. Fits to the angular distribution of the continuum for E{sub x} = 25 MeV show that <15% of the E0 EWSR is present in the continuum. Hence 50% of the EO ...

1995-10-01

357

[sup 123]I-MIBG myocardial scintigraphy in diabetic patients. Association with autonomic neuropathy  

Energy Technology Data Exchange (ETDEWEB)

[sup 123]I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed in 20 diabetic patients (NIDDM) and 8 control subjects to investigate the association between clinical autonomic nerve dysfunction and myocardial accumulation of MIBG. We used coefficient variance of R-R interval (CV[sub R-R]) as a index of the autonomic neuropathy and categorized diabetes into two groups (CV[sub R-R][>=]2.0: non-autonomic neuropathy. CV[sub R-R]<2.0: autonomic neuropathy). In planar imaging studies, heart to mediastinum MIBG uptake ratio (H/M) was calculated on both early and delayed images. The washout ratio of [sup 123]I-MIBG in the heart (%WR) was also obtained using myocardial tracer activity on the both images. Mean value of these indices in diabetic group did not reveal any significant difference with the value in the control group. On the SPECT images, low uptake was observed in the posterior-inferior wall with normal uptake of [sup 201]Tl in diabetic ...

1994-09-01

358

Wilsonville Advanced Coal Liquefaction Research and Development Facility technical progress report. Run 244 with Illinois 6 coal  

Science.gov (United States)

This report presents the operating results for Run 244 at the Advanced Coal Liquefaction R and D Facility in Wilsonville, Alabama. This run was made in an all-distillate Integrated Two-Stage Liquefaction (ITSL) mode using Illinois 6 coal from the Burning Star mine. The primary objective was to demonstrate the effects of temperature programming an aged catalyst batch on the ITSL product slate, especially on the net C/sub 1/-C/sub 5/ gas production and hydrogen consumption. Other objectives were to demonstrate the effect of fresh catalyst addition and to age the catalyst batch for an extended run with catalyst addition and withdrawal. Run 244 began on 4 July 1983 and continued through 27 September 1983. During this period, 182.9 tons of coal was fed in 1872 hours of operation. Seven special product workup material balances and two hydrotreater balances were defined, and the results are presented herein. From 27 to 30 September, 7.4 tons of Wyodak (Clovis Point mine) subbituminous coal ...

1984-05-01

359

The present state of nuclear medicine practice in Japan; A report of the 3rd nationwide survey in 1992  

Energy Technology Data Exchange (ETDEWEB)

The Subcommittee for Surveillance of Nuclear Medicine Practice has implemented a survey for actual nuclear medicine practice in Japan every 5 years. This article reports on the third survey implemented during a one-month period in June 1992. Questionnaires were sent to all 1256 facilities employing radiopharmaceuticals in routine practice, and 1162 (92.5%) answered. In vivo nuclear medicine examinations per day were performed in 6600 cases. SPECT accounted for 19.4%, as compared with 7.1% in the 1987 survey. According to organs, the frequency of examination for the cerebrospinal region was 3.2 and 2.2 times higher than that in the 1982 and 1987 surveys, respectively, whereas for the thyroid gland it was 0.6-fold and 0.7-fold that of these surveys. The proportion of bone scintigraphy was the highest (24.5%), followed by tumor scintigraphy (14.1%) and myocardial scintigraphy (11.9%). The frequency of myocardial and cerebral blood flow scintigraphy was dramatically increased as compared ...

1993-09-01

360

SR 97 - Alternative models project. Discrete fracture network modelling for performance assessment of Aberg  

Energy Technology Data Exchange (ETDEWEB)

As part of studies into the siting of a deep repository for nuclear waste, Swedish Nuclear Fuel and Waste Management Company (SKB) has commissioned the Alternative Models Project (AMP). The AMP is a comparison of three alternative modeling approaches for geosphere performance assessment for a single hypothetical site. The hypothetical site, arbitrarily named Aberg is based on parameters from the Aespoe Hard Rock Laboratory in southern Sweden. The Aberg model domain, boundary conditions and canister locations are defined as a common reference case to facilitate comparisons between approaches. This report presents the results of a discrete fracture pathways analysis of the Aberg site, within the context of the SR 97 performance assessment exercise. The Aberg discrete fracture network (DFN) site model is based on consensus Aberg parameters related to the Aespoe HRL site. Discrete fracture pathways are identified from canister locations in a prototype repository design to the surface of ...

1999-08-01

361

RangerMaster{trademark}: Real-time pattern recognition software for in-field analysis of radiation sources  

Energy Technology Data Exchange (ETDEWEB)

RangerMaster{trademark} is the embedded firmware for Quantrad Sensor`s integrated nuclear instrument package, the Ranger{trademark}. The Ranger{trademark}, which is both a gamma-ray and neutron detection system, was originally developed at Los Alamos National Laboratory for in situ surveys at the Plutonium Facility to confirm the presence of nuclear materials. The new RangerMaster{trademark} software expands the library of isotopes and simplifies the operation of the instrument by providing an easy mode suitable for untrained operators. The expanded library of the Ranger{trademark} now includes medical isotopes {sup 99}Tc, {sup 201}Tl, {sup 111}In, {sup 67}Ga, {sup 133}Xe, {sup 103}Pa, and {sup 131}I; industrial isotopes {sup 241}Am, {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 40}K, {sup 60}Co, {sup 232}Th, {sup 226}Ra, and {sup 207}Bi; and nuclear materials {sup 235}U, {sup 238}U, {sup 233}U, and {sup 239}Pu. To accomplish isotopic identification, a simulated ...

1998-12-31

362

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal projections ...

2006-01-15

363

Optically stimulated luminescence and thermoluminescence in CVD diamond and dosimetric evaluation in fields of ionizing radiation; Luminiscencia opticamente estimulada y termoluminiscencia en diamante DQV y evaluacion dosimetrica en campos de radiacion ionizante  

Energy Technology Data Exchange (ETDEWEB)

The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it presents the polluted ...

2006-07-01

364

Neutron cross section measurements using the ORELA: "6"0Ni(n,x), "4"0Ca(n,x), "2"2Ne(n,#gamma#), "1"8"9Os(n,n'), /sup 186,187,188,189/Os(n,x), "1"8"9Os(n,#gamma#), /sup 148,149,150/Sm(n,#gamma#), "1"7"9Ta(n,#gamma#), /sup 86,87,88/Sr(n,x), "4"0Ar(n,x), the stable tellurium isotopes (n,#gamma#) and "2"0"5Tl(n,x). Progress report, September 1, 1984-August 31, 1985  

International Nuclear Information System (INIS)

The research performed during this reporting period (9/1/84 to 8/31/85) resulted in: (1) publication of three papers; (2) presentation of an invited paper to the conference on ''Neutron-Nucleus Collisions: A Probe of Nuclear Structure''; (3) presentation of three contributed papers at APS meetings; and (4) preparation of three manuscripts, two of which are in the process of internal review at the Oak Ridge National Laboratory and are included with this report, and the third is being typed as this report is being written. The publications and papers deal with topics in both nuclear structure and astrophysics. Our efforts to study the systematic behavior of the optical model potential in the energy region just above neutron binding has been made substantially more reliable with the publication of a paper which discusses the accuracy of the methods used to average the measured scattering matrix. In the area of stellar nucleosynthesis, comparison of our model calculations and measured ...

365

High-Performance, Superparamagnetic, Nanoparticle-Based Heavy Metal Sorbents for Removal of Contaminants from Natural Waters  

Energy Technology Data Exchange (ETDEWEB)

We describe the synthesis and characterization of superparamagnetic iron oxide nanoparticle based heavy metal sorbents with various surface chemistries that demonstrate an excellent affinity for the separation of heavy metals in contaminated water systems (i.e. spiked Columbia river water). The magnetic nanoparticle sorbents are prepared from an easy to synthesize iron oxide precursor, followed by a simple, one-step ligand exchange technique to introduce the organic surface functionality of interest chosen to target either specific or broader classes of heavy metals. Functionalized superparamagnetic nanoparticles are excellent sorbent materials for the extraction of heavy metal contaminants from environmental and clinical samples since they are easily removed from the media once bound to the contaminant by simply applying a magnetic field. These engineered magnetic nanoparticle sorbents have an inherently high active surface area (often > 100 m2/g), allowing for increased binding ...

2010-06-01

366

Dose coefficients for intakes of radionuclides via contaminated wounds.  

Science.gov (United States)

The NCRP Wound Model, which describes the retention of selected radionuclides at the site of a contaminated wound and their uptake into the transfer compartment, has been combined with the ICRP element-specific systemic models for those radionuclides to derive dose coefficients for intakes via contaminated wounds. These coefficients can be used to generate derived regulatory guidance (i.e., the activity in a wound that would result in an effective dose of 20 or 50 mSv, or in some cases, a organ-equivalent dose of 500 mSv) and clinical decision guidance (i.e., activity levels that would indicate the need for consideration of medical intervention to remove activity from the wound site, administration of decorporation therapy or both). Data are provided for 38 radionuclides commonly encountered in various activities such as nuclear weapons, fuel fabrication or recycling, waste disposal, medicine, research, and nuclear power. These include 3H, 14C, 32P, 35S, 59Fe, 57,58,60Co, 85,89,90Sr, ...

2011-05-01

367

Distributions of "1"3"7Cs, "2"0"1T1, "2"0"3Hg, "2"0"3Pb and "5"7Co in a rat hepatoma model. Comparison with "6"7Ga  

International Nuclear Information System (INIS)

The distribution of carrier-free "2"0"3Pb-acetate, "2"0"3HgCl_2, "5"7Cocl_2, "1"3"7CsCl and "2"0"1TlCl was investigated in rats bearing thigh-implanted Morris 7777 hepatomas. Viable and nonviable tumor tissue was collected in order to determine the relative affinities of the radiopharmaceutical for these tissues. The animals were sacrificed at 4, 24, 48, 72 and 96 hrs following intravenous injection. Washout of the radioisotope from the viable tumor tissue was rapid, the maximum concentration being reached on or before 4 hrs following injection. In contrast, residual activity within the nonviable tumor tissue decreased much more slowly and in some cases even increased with time. Viable tumor-to-muscle and nonvialbe tumor-to-muscle ratios for "2"0"3Pb, "2"0"3Hg and "5"7Co were comparable to the analogous ratios reported for "6"7Ga. However, none of these isotopes approached "6"7Ga as a potential tumor imaging agent because the large ratios were the result of low ...

368

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, the PGS system was ...

2007-09-21

369

Description of work vadose drilling at the 1301-N and 1325-N facilities, 100-NR-1 operable unit  

Energy Technology Data Exchange (ETDEWEB)

This description of work (DOW) details the field activities associated with the sampling of the vadose zone soils beneath the 1301-N and 1325-N cribs and trenches and will serve as a field guide for those performing the work. These activities are undertaken pursuant to the Hanford Federal Facility Agreement and Consent Order (Ecology et al., 1994a) Milestone M-16-94-01H-Tl and the June 30, 1994 Milestone Change Request M-16-94-02 (Ecology et al., 1994b). Three vadose zone borings, 1301-N-1, 1301-N-2, and 1325-N-1, will be constructed to investigate the vertical and horizontal distribution of radionuclide contamination in sediments beneath the cribs and trenches. The boreholes are also intended to intersect subsurface areas that may have been contaminated by dangerous wastes, i.e., metals, in effluent disposed during past operation of the facilities. This limited field investigation will provide data for the evaluation of remedial alternatives. Data from the ...

1994-08-01

370

Cellular dosimetry: Absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments  

Energy Technology Data Exchange (ETDEWEB)

The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, {sup 86}Rb, {sup 89}Sr, {sup 90}Y, {sup ...

1994-02-01

371

ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation  

International Nuclear Information System (INIS)

Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, 45Rh-103M, 45Rh-105M, 45Rh-105, 45Rh-106, ...

372

XPS study on the correlation between chemical state and oxygen-sensing properties of an iron oxide thin film  

International Nuclear Information System (INIS)

We have studied the correlation between the chemical state and the oxygen-sensing properties of an iron oxide thin film using a setup that allows simultaneous sensor resistance measurements and X-ray photoelectron spectroscopy (XPS) data acquisition. The gas exposures were performed at the highest operating pressure of the XPS spectrometer at a controlled sample temperature which allows direct comparison between the sensor response and the chemical state of the surface. The iron oxide film was modified by a sequence of argon ion sputtering steps and the induced changes in the chemical state, resistance, and sensitivity to oxygen were investigated. The sputtering was found to reduce the iron from the Fe"3"+ to the Fe"2"+ state and to decrease the sensor resistance. The measured sensitivity to oxygen first increased by a factor of two but then collapsed to its original level. The mechanism for oxygen sensing was found to be filling of the oxygen vacancies in the ...

2007-10-15

373

Thermal-neutron capture cross section and resonance integral of americium-241  

International Nuclear Information System (INIS)

The thermal-neutron capture cross section (#sigma#_0_,_g) and the resonance integral (I_0_,_g) leading to the ground state of "2"4"2Am were measured by an activation method for neutron capture by "2"4"1Am. A method with gadolinium, which was similar to the cadmium difference method, was used to measure the cross section #sigma#_0_,_g with attention to resonances of "2"4"1Am. Americium chloride samples containing "2"4"1Am radioisotope were irradiated for 68 h in the long-irradiation plug of the Kyoto University Research Reactor, KUR. Wires of Co/Al and Au/Al alloys were used as monitors to determine thermal-neutron fluxes and epithermal Westcott's indexes at the irradiation positions. An #alpha#-ray spectrometer was used to measure the activity ratios of "2"4"2Cm to "2"4"1Am. On the basis of Westcott's convention, the #sigma#_0_,_g and I_0_,_g values were determined as 628#+-#22 b and 3.5#+-#0.3 kb, respectively. (author)

2007-12-01

374

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas ...

2005-03-17

375

The influence of electromagnetic field irradiated by high-voltage transmission lines on properties of cells.  

Science.gov (United States)

The influence of low-frequency electromagnetic field irradiating by high-voltage transmission lines on signal transduction of cell in spleen cells of the rates have been studied by molecular-biology techniques. The spleen cells are extracted from skilled rates, which are exposed in the electromagnetic field of high-voltage transmission lines with 4000 V/m and 0.09-0.1 G about 400 days. The quantity or level of phosphorylation of signal transducer and activator of transcription (STAT3) in JAK-STAT signal transduction pathway of spleen cells, which are stimulated and unstimulated by IL-2, respectively, are detected by the immunoblotting and immunobiochemistry. The results show that the expression of phospho-STAT3 in spleen cell stimulated by IL-2 differ not from that in the unstimulated cell. The former is significantly large than the latter. This shows that signal transduction of cell is affected by this electromagnetic field. The spectra of infrared absorption for the general ...

2005-01-01

376

The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger ...

2009-01-01

377

TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams  

International Nuclear Information System (INIS)

A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in very good agreement with both theoretical ...

2010-03-11

378

Stereoscopic observations of a solar hard x-ray flare with Ulysses, PVO, GRO and Yohkoh spacecraft  

Energy Technology Data Exchange (ETDEWEB)

Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their implications regarding the directivity of hard X-ray sources in ...

1992-01-01

379

Selective adsorption of uranium on activated charcoal from electrolytic aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

Adsorption of uranium onto various solids is important from purification, environmental, and radioactive waste disposal points of view. Adsorption of uranium on activated charcoal has been studied as a function of shaking time, amount of adsorbent, pH, concentration of adsorbate, and temperature. Uranium adsorption obeys the Langmuir isotherm. {Delta}H{degrees} and {Delta}S{degrees} were calculated from the slope and intercept of plots ln K{sub D} vs 1/T. The influence of different anions and cations on uranium adsorption has been examined. The adsorption of other metal ions on activated charcoal has been studied under specified conditions to check its selectivity; consequently, uranium was removed from Cs, Ba, Zn, and Co. More than 98% adsorbed uranium on activated charcoal can be recovered with 65 ml of 3 M HNO{sub 3} solution. A wavelength dispersive x-ray fluorescence spectrometer was used for measuring uranium concentration.

1992-02-01

380

Radiometric analysis of raw materials and end products in the Turkish ceramics industry  

International Nuclear Information System (INIS)

This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. The results suggest ...

2011-05-01

381

Radiations emitted in the decay of /sup 165/Er: A promising medical radionuclide  

Science.gov (United States)

The 10.3-h /sup 165/Er, decaying by electron capture to stable /sup 165/Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in /sup 165/Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of /sup 169/Er and /sup 171/Er radioactive impurities in the reactor-produced /sup 165/Er sample are experimentally determined. Whole-body dose estimates for /sup 165/Er are given. These compare favorably with /sup 99/Tc dose.

1977-05-01

382

Radiations emitted in the decay of "1"6"5Er: A promising medical radionuclide  

International Nuclear Information System (INIS)

The 10.3-h "1"6"5Er, decaying by electron capture to stable "1"6"5Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in "1"6"5Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of "1"6"9Er and "1"7"1Er radioactive impurities in the reactor-produced "1"6"5Er sample are experimentally determined. Whole-body dose estimates for "1"6"5Er are given. These compare favorably with "9"9Tc dose.

383

Pre-transitional disk nature of the AB Aur disk  

CERN Document Server

The disk around AB Aur was imaged and resolved at 24.6\\,$\\mu$m using the Cooled Mid-Infrared Camera and Spectrometer on the 8.2m Subaru Telescope. The gaussian full-width at half-maximum of the source size is estimated to be 90 $\\pm$ 6 AU, indicating that the disk extends further out at 24.6\\,$\\mu$m than at shorter wavelengths. In order to interpret the extended 24.6\\,$\\mu$m image, we consider a disk with a reduced surface density within a boundary radius $R_c$, which is motivated by radio observations that suggest a reduced inner region within about 100 AU from the star. Introducing the surface density reduction factor $f_c$ for the inner disk, we determine that the best match with the observed radial intensity profile at 24.6\\,$\\mu$m is achieved with $R_c$=88 AU and $f_c$=0.01. We suggest that the extended emission at 24.6\\,$\\mu$m is due to the enhanced emission from a wall-like structure at the boundary radius (the inner edge of the outer disk), which ...

2010-01-01

384

Population of nuclei close to N=Z line for A{approx}100 through emission of complex fragments and light charged particles  

Energy Technology Data Exchange (ETDEWEB)

High spin states of the proton rich nuclei in the mass region A {approx} 100 have been studied at the GASP spectrometer through the evaporation of light charged particles and heavier ions detected in the 4{pi} Si-ball Isis. Rear side injection and pulse shape analysis have allowed a good discrimination among protons, alpha particles and heavy ions up to C. Of the several nuclei populated in the reactions we will discuss here the high spin states of {sup 105} Sn. In addition to an extension of the spherical level, scheme, a regular sequence of dipole transitions has been found, The states of the dipole band are suggested to be built on a neutron h{sup 2}{sub 11/2} excitation coupled to proton particle-hole states, which polarize the core to a slightly prolate shape. The experimental results are in agreement with the prediction of tilted axis cranking calculations, which satisfactorily explain the properties of the band. (author) 17 refs., 4 figs.

1997-12-31

385

Oxygen carriers for chemical looping combustion of solid fuels  

Energy Technology Data Exchange (ETDEWEB)

A thermal analyzer-differential scanning calorimeter-mass spectrometer (TG-DSC-MS) was used to study oxygen carriers (OC) for their potential use for the application of chemical looping combustion (CLC) to solid fuels. Reaction rates, changes in reaction rates with repeated oxidation-reductions, exothermic heats during oxidation, and the effect of changing reduction gas compositions were studied. Oxidation rates were greater than reduction rates and reaction rates were reproducible through multiple oxidation-reduction cycles except where agglomeration occurred with powders. Iron oxide (Fe{sub 2}O{sub 3} powder) and iron-based catalysts were found suitable for CLC of solid fuels having rapid reduction rates which increased with higher reducing gas concentrations. Fe{sub 2}O{sub 3} powder was used to oxidize a high carbon coal char in an inert gas removing 88% of the carbon from the char. Other properties such as cost and durability indicated iron oxide OCs potential ...

2009-05-15

386

On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir  

Science.gov (United States)

Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five meters from the instrument. Application of the device to acid an ...

1992-01-01

387

Method of calibration to correct for cloud-induced wavelength shifts in the Aura satellite's Ozone Monitoring Instrument  

Science.gov (United States)

The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is expected that these wavelength variations ...

2006-05-01

388

Measurement of the antiproton/proton ratio at few-TeV energies with the ARGO-YBJ experiment  

CERN Document Server

Cosmic ray antiprotons provide an important probe for the study of cosmic-ray propagation in the interstellar space and to investigate the existence of Galactic dark matter. Cosmic rays are hampered by the Moon, therefore a deficit of cosmic rays in its direction is expected (the so-called "Moon shadow"). The Earth-Moon system acts as a magnetic spectrometer. In fact, due to the geomagnetic field the center of the Moon shifts westward by an amount depending on the primary cosmic ray energy. Paths of primary antiprotons are therefore deflected in an opposite sense in their way to the Earth. This effect allows, in principle, the search of antiparticles in the opposite direction of the observed Moon shadow. The ARGO-YBJ experiment, in stable data taking since November 2007 with an energy threshold of a few hundreds of GeV, is observing the Moon shadow with high statistical significance. Using about 1 year data, an upper limit of the antip/p flux ratio in the few-TeV ...

2009-01-01

389

Measurement of the Electron Affinities of Indium and Thallium  

Energy Technology Data Exchange (ETDEWEB)

The electron affinities of indium and thallium were measured in separate experiments using the laser-photodetachment electron spectroscopy technique. The measurements were performed at the University of Nevada, Reno. Negative ion beams of both indium and thallium were extracted from a cesium-sputter negative ion source, and mass analyzed using a 90{sup o} bending magnet. The negative ion beam of interest was then crossed at 90{sup o} with a photon beam from a cw 25-Watt Ar{sup +} laser. The resulting photoelectrons were energy analyzed with a 160{sup o} spherical-sector spectrometer. The electron affinity of In({sup 2}P{sub 1/2}) was determined to be 0.404 {+-} 0.009 eV and the electron affinity of thallium was determined to be 0.377 {+-} 0.013 eV. The fine-structure splittings in the ground states of the negative ions were also determined. The experimental measurements will be compared to several recent theoretical predictions.

1999-03-20

390

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable promise for quality assurance because (1) a ...

1978-01-01

391

Mass measurements of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc and their impact on the rp-process  

Energy Technology Data Exchange (ETDEWEB)

The masses of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of measurements and calculations are presented, and the issue of a potential Zr-Nb cycle is addressed.

2010-07-01

392

Mass measurements of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc and their impact on the rp-process  

International Nuclear Information System (INIS)

The masses of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of measurements and calculations are presented, and the issue of a potential Zr-Nb cycle is addressed.

2010-03-15

393

Line intensity enhancements in stellar coronal X-ray spectra due to opacity effects  

CERN Document Server

Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret this enhancement in ...

2008-01-01

394

Launch of the Space experiment PAMELA  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger mode the ...

2007-01-01

395

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector fabrication procedures, I-V and C-V ...

1992-10-01

396

K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma  

Energy Technology Data Exchange (ETDEWEB)

K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.

1985-05-01

397

Ion-induced M X-ray emission from heavy lanthanides  

Energy Technology Data Exchange (ETDEWEB)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.

1987-12-01

398

Interaction of 8 MeV /sup 12/C with /sup 88/Sr; neutron transfer, inelastic scattering and spin alignment of the 2/sup +/ state of /sup 12/C  

Energy Technology Data Exchange (ETDEWEB)

Using a Q3D magnetic spectrometer the elastic and inelastic scattering of /sup 12/C on /sup 88/Sr and the neutron pick-up (/sup 12/C, /sup 13/C) has been studied. The spin alignment of the inelastically excited 2/sup +/ state of /sup 12/C (4.43 MeV) has been deduced from the line shapes broadened by the ..gamma..-decay in flight. Thus for each m-substate a full angular distribution was obtained. The m = 1 substate shows a shifted interference minimum, which is explained by the different strength of the Coulomb and nuclear amplitudes in the m-substates. The analysis of the data on elastic scattering, inelastic scattering, alignment and the neutron transfer can be described consistently with one choice of the optical model parameters.

1982-04-01

399

Integration and Testing of the Micro-X Rocket Payload  

Science.gov (United States)

The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets include the core of the Virgo cluster and ...

2011-05-01

400

Infrared Observations During the Secondary Eclipse of HD 209458b I. 3.6-Micron Occultation Spectroscopy Using the VLT  

CERN Document Server

We search for an infrared signature of the transiting extrasolar planet HD 209458b during secondary eclipse. Our method, which we call `occultation spectroscopy,' searches for the disappearance and reappearance of weak spectral features due to the exoplanet as it passes behind the star and later reappears. We argue that at the longest infrared wavelengths, this technique becomes preferable to conventional `transit spectroscopy'. We observed the system in the wing of the strong nu-3 band of methane near 3.6 microns during two secondary eclipses, using the VLT/ISAAC spectrometer at a spectral resolution of 3300. Our analysis, which utilizes a model template spectrum, achieves sufficient precision to expect detection of the spectral structure predicted by an irradiated, low-opacity (cloudless), low-albedo, thermochemical equilibrium model for the exoplanet atmosphere. However, our observations show no evidence for the presence of this spectrum from the exoplanet, with ...

2003-01-01

401

Inclusive K{sup +}-meson production in proton-nucleus interactions  

Energy Technology Data Exchange (ETDEWEB)

The production of K{sup +}-mesons in pA(A=D,C,Cu,Ag,Au) collisions has been investigated at the COoler SYnchrotron COSY-Juelich for beam energies T{sub p}=1.0-2.3 GeV. Double differential inclusive pC cross-sections at forward angles {theta}{sub K+}<12 as well as the target mass dependence of the K{sup +} momentum spectra have been measured with the ANKE spectrometer. Far below the free NNthreshold at T{sub NN}=1.58 GeV the spectra reveal a high degree of collectivity in the target nucleus. From the target mass dependence of the cross-sections at higher energies, the repulsive in-medium potential of the K{sup +}-mesons can be deduced. Using pNcross-section parameterisations from the literature and our measured pD data we derive a cross-section ratio {sigma}(pn{yields}K{sup +}X)/{sigma}(pp{yields}K{sup +}X) {proportional_to}(3-4). (orig.)

2004-11-01

402

Formation of Si-nanoparticles in a microwave reactor: Comparison between experiments and modelling  

International Nuclear Information System (INIS)

The formation and growth of silicon-nanoparticles from silane in a microwave reactor was investigated. Experiments were performed for the following conditions: precursor concentration 380-2530 ppm, pressures of 20-30 mbar, microwave powers 120-300 W. The formed particles were examined in-situ with a particle mass spectrometer. Additionally, particles were collected on grids and analyzed by transmission electron microscopy, X-ray diffraction, and by determining the specific surface area by BET. The particle size was found to be in the range of 5-8 nm in diameter. A simple model was used to simulate the particle formation processes taking place inside the reactor. The microwave energy coupled into the reactor flow was treated as a spatially distributed energy source resulting in a local temperature increase. The particles were assumed to have a monodisperse size distribution. To allow an approximation of their shape they were characterized by their volume and surface ...

2005-02-01

403

First direct mass measurement of the proton rich nuclides {sup 85,86,87}Mo and {sup 87}Tc  

Energy Technology Data Exchange (ETDEWEB)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction {sup 36}Ar+{sup 54}Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and {nu}p process paths. The masses of {sup 85}Mo and {sup 87}Tc were measured for the first time. The masses of another two nuclides, {sup 86,87}Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of {sup 86}Zr and {sup 85}Nb were measured and found to be in agreement with the values obtained at JYFLTRAP. The experiment as well as preliminary data on ...

2009-07-01

404

First direct mass measurement of the proton rich nuclides "8"5","8"6","8"7Mo and "8"7Tc  

International Nuclear Information System (INIS)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction "3"6Ar+"5"4Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and #nu#p process paths. The masses of "8"5Mo and "8"7Tc were measured for the first time. The masses of another two nuclides, "8"6","8"7Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of "8"6Zr and "8"5Nb were measured and found to be in agreement with the values obtained at JYFLTRAP. The experiment as well as preliminary data on mass values, separation ...

2009-03-16

405

FT-IR spectroscopic studies of polycyclic aromatic hydrocarbons  

International Nuclear Information System (INIS)

Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared absorption coefficients instead of those at the temperature of interest because of the latter's ...

1990-04-01

406

Establishing a Connection Between Active Region Outflows and the Solar Wind: Abundance Measurements with EIS/Hinode  

CERN Document Server

One of the most interesting discoveries of the X-ray Telescope and EUV Imaging Spectrometer (EIS) on board the Hinode solar observatory is the presence of persistent high temperature high speed outflows from the edges of active regions. Measurements by EIS indicate that the outflows reach velocities of 50 km/s with spectral line asymmetries approaching 200 km/s. It has been suggested that these outflows may lie on open field lines that connect to the heliosphere, and that they could potentially be a significant source of the slow speed solar wind. A direct link has been difficult to establish, however. In this letter, we use EIS measurements of spectral line intensities that are sensitive to changes in the relative abundance of Si and S as a result of the first ionization potential (FIP) effect, to measure the chemical composition in the outflow regions of AR 10978 over a period of 5 days in December 2007. We find that Si is always enhanced over S by a factor of ...

2010-01-01

407

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or loops. 59 references.

1988-01-01

408

Effects of relativity and 'atomic structure' in the KLL Auger spectrum of "8"8Sr generated in the EC-decay of "8"8Y  

International Nuclear Information System (INIS)

The KLL Auger electron spectrum of "8"8Sr generated in the EC-decay of "8"8Y has been analyzed at the instrumental resolution of 11 eV using a combined electrostatic spectrometer. Energies and relative intensities of the all nine transitions were determined and compared with theoretical predictions. Our value of 12067.3(12) eV measured for the absolute energy of the dominant KL_2L_3("1D_2) transition was found to be higher by 7.4 eV (i.e., more than 3#sigma#) than that one obtained in a measurement with external excitation. The discrepancy indicates substantial influence of the 'atomic structure effect' on absolute transition energies in our experiment. Very good agreement of the measured 0.14(3) and predicted 0.12 values for the KL_1L_2("3P_0/"1P_1) Auger transition intensity ratio clearly proved the predicted strong influence of the relativistic effects on the KL_1L_2("3P_0) transition rate even at Z = 38.

2007-08-01

409

Effects of oxygenated blending compounds on emissions from a turbo-charged direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation was conducted to evaluate the effect of three different oxygenated compounds, diglyme, diethyl maleate and dibutyl maleate, on emissions from a Volkswagen 1.9 litre, turbocharged, direct injection diesel engine. Sampling was performed using a mini-dilution tunnel technique to obtain particulate matter and a Fourier transform infrared (FTIR) spectrometer for gaseous emissions. The particulate samples were analysed using thermal analysis and Soxhlet extraction to determine the fraction of volatile and soluble organic material respectively. All three oxygenated compounds were found to be effective at reducing particulate emissions, with the maleate compounds being more effective overall than the diglyme. Analysis of the relative contributions of changes in the soot and soluble organic fraction (SOF) to the reduction of particulate matter indicated that, for diethyl maleate and diglyme, reductions in soot were the dominant effect. No ...

2000-02-01

410

Effect of various coal contaminants on the performance of solid oxide fuel cells: Part II. ppm and sub-ppm level testing  

Energy Technology Data Exchange (ETDEWEB)

The poisoning effects of various trace contaminants in the coal-derived syngas stream at ppm and sub-ppm level on the performance of Ni-YSZ/YSZ/LSM solid oxide fuel cells were studied at extended duration. The thermochemical nature of impurities such as PH{sub 3}(g) and CH{sub 3}Cl(g) in presence and absence of water steam was analyzed by a high temperature mass spectrometer. Only less than half of PH{sub 3}(g) is hydrolyzed, and CH{sub 3}Cl(g) also co-exist with HCl(g). After a certain duration of exposure, 1 ppm AsH{sub 3}(g), 0.5 ppm PH{sub 3}(g), and 2.5 ppm CH{sub 3}Cl(g) all caused some degree of degradation to the power density at 750 C. Whereas 1 ppm of H{sub 2}S(g) resulted in immediate performance loss. The mechanisms of degradation are mainly divided into two categories: surface adsorption effect (for S and Cl) and bulk reaction effect (for As and P). The controversies regarding the poisoning effect and mechanism of S are also discussed with the aid of ...

2009-09-05

411

Dynamic behaviors of sulfur evolved in the gas phase from pyrolysis of six Chinese coals  

Energy Technology Data Exchange (ETDEWEB)

Dynamic behaviors of gaseous sulfur-containing compounds evolved from pyrolysis of six Chinese coals were studied in the temperature range of up to 800{sup o}C under N{sub 2} and H{sub 2}. The released amount of total sulfur-containing gases was traced by an online flame photometric detector (FPD). Simultaneously, the changes of different sulfur forms, including H{sub 2}S, SO{sub 2}, COS and CS{sub 2}, also were investigated using an online mass spectrometer (MS). FPD results show that the effect of H{sub 2} on gaseous sulfur evolved is complex, which promoted certain peak and suppresses other peaks. Based on the data from MS, it is suggested that a series of competitive reactions between active sulfur and other active matters during pyrolysis may impact on the sulfur form in gas phase. Interactions between active sulfur-containing intermediates and the coal matrix are attributed to be the main factor determining the dynamic behavior.

2006-07-01

412

Direct sampling ion trap mass spectrometry (DSITMS). Innovative technology summary report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the cost, performance, and other key characteristics of an innovative technology for determining the presence or absence, and measuring the concentration, of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in groundwater and soil, and in gaseous remediation process streams at hazardous waste sites. This new technology is Direct Sampling Ion Trap Mass Spectrometry (DSITMS). DSITMS introduces sample materials directly into an ion trap mass spectrometer by means of a very simple interface, such as a capillary restrictor or a polymer membrane. There is typically very little, if any, sample preparation and no chromatographic separation of the sample constituents. This means that the response of the instrument to the analytes or contaminants in a sample is nearly instantaneous, and that analytical methods based on DSITMS are fast. Analyses are typically completed in less than five minutes, and the analysis cost is ...

1998-12-01

413

Design and implementation of the BESIII detector-control system  

Energy Technology Data Exchange (ETDEWEB)

In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has been developed for the LCL. Network communication and web server ...

2008-07-21

414

Delayed-neutron energy spectra following thermal-neutron-induced fission of Pu-239  

Energy Technology Data Exchange (ETDEWEB)

Delayed-neutron (DN) energy spectra following thermal neutron induced fission of /sup 239/Pu as a function of time after fission have been measured, using the beta-neutron time-of-flight (TOF) spectrometer at the University of Lowell. Thermal/epithermal neutrons were produced on the 5.5-MV Van de Graaff accelerator using the /sup 7/Li(p,n)/sup 7/Be reaction. Time spectra over the neutron energy range of 0.01-4.0 MeV were measured for seven different time intervals after fission, each interval containing varying contributions from the six delayed neutrons groups. The DN energy spectra following induced thermal fission of /sup 239/Pu are compared to those resulting from induced thermal fission of /sup 235/U for each of the seven delay time intervals. Decomposition of the measured spectra into six-group DN spectra was accomplished employing an iterative least-squares method, incorporating a constraint requiring all six-group spectra remain positive for all neutron ...

1987-01-01

415

Delayed backbending in the #pi#h _9_/_2 band of "1"8"7Ir  

International Nuclear Information System (INIS)

High-spin states of "1"8"7Ir have been populated in the "1"7"6Yb("1"5N,4n) reaction and measured with the YRAST Ball spectrometer. The #pi#h _9_/_2 rotational band has been extended beyond the first alignment crossing, which was found at rotational frequency (#Planck constant#/2#pi#)#omega# _c #approx =#0.39 MeV . Two different scenarios for describing this crossing are considered: the alignment of an h _9_/_2 proton or i _1_3_/_2 neutron pair and it is concluded that a proton band crossing is more likely. A systematic study of the rotational alignment crossings in the #pi#h _9_/_2 bands in the N=104,106,108 isotopes of _7_3Ta,_7_5Re,_7_7Ir, and _7_9Au is presented.

2003-11-01

416

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is being developed to ...

1988-10-01

417

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The detector is housed in a massive shield ...

1992-03-16

418

Born-Oppenheimer breakdown effects and hyperfine structure in the rotational spectrum of strontium monosulfide, SrS  

Energy Technology Data Exchange (ETDEWEB)

A newly constructed Fourier transform microwave spectrometer has been used to record the pure rotational spectra of four isotopomers of SrS ({sup 88}Sr{sup 32}S, {sup 87}Sr{sup 32}S, {sup 86}Sr{sup 32}S, and {sup 88}Sr{sup 34}S) between 6 and 26 GHz. The molecules were produced by reacting laser ablated strontium with carbonyl sulfide (0.1% in argon). Pure rotational transitions in the ground, first and second vibrational states have been observed. The data set has enabled a multi-isotopomer fit. Born-Oppenheimer breakdown terms for both atoms have been determined. The {sup 87}Sr nuclear quadrupole coupling constant in {sup 87}Sr{sup 32}S has been determined for the first time.

2007-12-06

419

A new measurement of the antiproton-to-proton flux ratio up to 100 GeV in the cosmic radiation  

CERN Document Server

A new measurement of the cosmic ray antiproton-to-proton flux ratio between 1 and 100 GeV is presented. The results were obtained with the PAMELA experiment, which was launched into low-earth orbit on-board the Resurs-DK1 satellite on June 15th 2006. PAMELA is equipped with a silicon-microstrip magnetic spectrometer and a silicon-tungsten imaging calorimeter and has been collecting data since July 2006. During 500 days of data collection a total of about 1000 antiprotons have been identified, including 100 above an energy of 20 GeV. The high-energy results are a ten-fold improvement in statistics with respect to all previously published data. The antiproton-to-proton flux ratio increases smoothly with energy up to about 10 GeV, in agreement with previous experiments, and then levels off. The data follow the trend expected from secondary production calculations and significantly constrain contributions from exotic sources, e.g. dark matter particle annihilations.

2008-01-01

420

A gas-jet ECR ion source at TRIGA-SPEC  

International Nuclear Information System (INIS)

The TRIGA-SPEC experiment has been installed recently at the research reactor TRIGA Mainz. Ground state properties like masses, charge radii, spins, and moments of short-lived nuclides can be determined with very-high precision using the Penning trap mass spectrometer TRIGA-TRAP, and the collinear laser spectroscopy setup TRIGA-LASER. Short-lived neutron-rich radionuclides in the mass range 80 < A < 140 are produced by thermal neutron induced fission of e.g. U-235, Pu-239 or Cf-249, respectively. For the extraction and ionization of the fission products a gas-jet system is coupled to a 2.45-GHz ECR ion source for the production of singly charged ions. The gas-jet has been tested on-line and fission products have been extracted. First off-line tests of the ion source have been performed successfully with argon gas. The results of the commissioning test of the ion source and the on-line coupling of the experiments are presented.

2010-03-08

421

A facile one-pot hydrothermal method to prepare europium-doped titania hollow phosphors and their sensitized luminescence properties  

British Library Electronic Table of Contents (United Kingdom)

Monodisperse europium-activated titania hollow phosphors had been synthesized by a facile one-pot hydrothermal method using carbon spheres as hard templates. Samples were characterized by X-ray powder diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, energy dispersive spectrometer and photoluminescence spectrum. The strongest emission intensity was observed with TiO2:Eu0.2 hollow spheres and TiO2:Eu0.2 hollow spheres calcining at 550^oC. Moreover, the strongest excitation of TiO2:Eu0.2 hollow spheres transferred from 400 to 500^oC and the effective nonradiative energy transfer from the TiO2 hollow spheres host matrix to Eu^3^+ ions crystal field states was realized due to changes of crystalline field in the environment around Eu^3^+ ions occupying Ti^4^+ site...

2010-01-01

422

A Single-Shot Method for Measuring Femtosecond Bunch Length in Linac-Based Free-Electron Lasers  

International Nuclear Information System (INIS)

There is growing interest in the generation and characterization of femtosecond and subfemtosecond pulses from linac-based free-electron lasers (FELs). In this report, following the method of Ricci and Smith (Phys. Rev. ST Accel. Beams 3, 032801 (2000)), we investigate the measurement of the longitudinal bunch profile of an ultrashort electron bunch produced by these FELs. We show that this method can be applied in a straightforward manner at x-ray FEL facilities such as the Linac Coherent Light Source by slightly adjusting the second bunch compressor followed by running the bunch on an rf zero-crossing phase of the final linac. We find that the linac wakefield strongly perturbs the measurement, and through analysis show that it can be compensated in a simple way. We demonstrate the effectiveness of this method and wakefield compensation through numerical simulations, including effects of coherent synchrotron radiation and longitudinal space charge. When used in conjunction with a ...

2010-08-26

423

Investigation of flora and fauna species of Lake Baikal by electron-probe microanalysis  

International Nuclear Information System (INIS)

Complete text of publication follows. Baikal is an ancient unique lake. The sweet water of Baikal is crystal clean; it concentrates oxygen and contains scarce silicon. This feature is provoked very particular interest for scientists and poses some awkward questions concerning the preservation of Baikal's ecosystem. A profound investigation of fish otholiths, animal teeth, sponges, valves of mollusks and diatom algae provides chronological information, possibility to reconstruct the events proceeding in the environment based on variations of their chemical composition. Because these study objects are small-sized, and some of them are micron-size, application of the electron-probe microanalysis turns to be quite productive. The goal of this study is to disclose performance capabilities of this method while investigating the Baikal flora and fauna. Investigations were performed by devices JCXA-733 and JXA-8200 using the electron microscope and x-ray microprobe modes. Measurements of ...

424

The Prognostic Significance of p53, Bcl-2, Cytokeratin 20 and Ki-67 in Primary Superficial Papillary Transitional Bladder Carcinoma  

International Nuclear Information System (INIS)

Identification of factors that determine individual patient risk for recurrence and progression in superficial papillary carcinoma of the bladder is a subject of extensive research as it would be a major outcome in patient management. It has been well recognized that traditional prognostic markers as tumor grade and stage are not accurate enough in predicting biological behavior. A large number of markers have been investigated as potential prognostic factors and relatively few can help in predicting outcome. Material and Methods: Forty-nine cases undergoing complete transurethral resection for primary superficial papillary transitional cell carcinoma were subjected to clinicopathologic evaluation as well as immunohistochemical staining for p53, bcl-2, cytokeratin 20 and Ki-67. The CAS-200 image analyzer was used to estimate the Ki-67 labeling index. Results: Recurrence was observed in 19 cases (38.8%) and progression in 7 cases (14.3%) with a median followup of 49 months (range 24-84 ...

2003-03-01

425

Study of the inorganic constituents in different species of Casearia medicinal plant collected in distinct regions of the Atlantic Forest, SP State, Brazil; Estudo sobre os constituintes inorganicos presentes em diferentes especies da planta medicinal do genero Casearia coletadas em regioes distintas da Mata Atlantica, SP  

Energy Technology Data Exchange (ETDEWEB)

The use of medicinal plants in the treatment of diseases has increased significantly in the last years, as has research concerning chemical characterization of these plants. In this study, inorganic constituents were determined in leaves and in extracts from three medicinal plant species of the Casearia genus (C. sylvestris, C. decandra and C. obliqua) collected in distinct regions of the Atlantic Forest, SP. The elemental compositions of the soils in which these plants were grown were also determined. Traditionally, these plants are used due to their antiinflammatory, antiacid, antiseptic and cicatrizing properties. The antiulcer and the antitumor activities of the Casearia genus and its capacity to neutralize snake and bee venoms, have also been scientifically confirmed. The analytical methodology used was neutron activation analysis. Long and short irradiation periods of the samples and the standards were carried out at IPEN's IEA-R1 nuclear research reactor. In the leaf K ...

2006-07-01

426

Solution conformations of CaCl sub 2 and Ca(NO sub 3 ) sub 2 complexes of chiral tetramethyl 18-crown-6 macrocycles: A 1D and 2D sup 1 H and sup 13 C NMR investigation  

Energy Technology Data Exchange (ETDEWEB)

One- and two-dimensional NMR techniques have been used to investigate the solution structures of (2S,6S,11S,15S)-2,6,11,15-tetramethyl-1,4,7,10,13,16-hexaoxacyclooctadecane (I) and (2R,3R,11R,12R)-2,3,11,12-tetramethyl-1,4,7,10,13,16-hexaoxyacyclooctadecane (II) macrocycle complexes of CaCl{sub 2} and Ca(NO{sub 3}){sub 2} in CDCl{sub 3}. Previous chiroptical studies of these and similar crown complexes by circularly polarized luminescence (CPL), total luminescence (TL), and circular dichroism (CD) spectroscopy have shown that the macrocycle asymmetric carbons in these complexes constrain the ring such that the sense of the ring twist in the S chiral ring complexes is opposite to that in the R chiral ring complexes. These studies have also shown that there is an added chirality element in the di- and trivalent (alkaline earth and lanthanide metal, respectively) nitrate complexes of I and II associated with the twist of the nitrate anions relative to one another as ...

1989-10-04

427

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, as was the influence of using the full ...

2009-05-26

428

{sup 48}Ti(n,xnpa{gamma}) reaction cross sections using spallation neutrons for E{sub n} = 1 to 20 MeV  

Energy Technology Data Exchange (ETDEWEB)

{gamma}-ray excitation functions have been measured for the interaction of fast neutrons with {sup 48}Ti (neutron energy from 1 MeV to 250 MeV). The Los Alamos National Laboratory spallation neutron source, at the LANSCE/WNR facility, provided a ''white'' neutron beam which is produced by bombarding a natural W target with a pulsed proton beam. The prompt-reaction {gamma} rays were measured with the large-scale Compton-suppressed Ge spectrometer, GEANIE. Neutron energies were determined by the time-of-flight technique. Excitation functions were converted to partial {gamma}-ray cross sections, taking into account the dead-time correction, the target thickness, the detector efficiency, and neutron flux (monitored with an in-line fission chamber). The data analysis is presented here for neutron energies between 1 to 20 MeV. Partial {gamma}-ray cross sections for transitions in {sup 47,48}Ti, {sup 48}Sc, and {sup 45}Ca have been ...

2005-01-06

429

[Fast neutron cross section measurements]. Progress report  

Energy Technology Data Exchange (ETDEWEB)

In this report, we outline the progress achieved in two distinct under the DOE-sponsored cross section project: the initial results obtained from the pulsed 14 MeV neutron facility, and a cooperative effort with Argonne National Laboratory in the measurement of fast neutron cross sections in yttrium. In the 14 MeV neutron laboratory, this year has seen the maturation of the project into one in which initial scattering measurements are now underway. We have improved the accelerator and ion source in several significant ways, so that neutron intensities have now been proven to be adequate for our series of elastic scattering angular distribution measurements outlined in our initial proposal of two years ago. We have successfully tested all components of the time-of-flight spectrometer and recorded initial neutron spectra from the ring targets that we have obtained for our first angular distribution measurements. Examples of the time-of-flight spectra that have been ...

1991-12-31

430

Utilization of a "1"3C enriched tracer for carbon flux studies in a tropical Eucalyptus exserta forest  

International Nuclear Information System (INIS)

Severe depletion of nutrients through removal of the above ground litter caused a cessation of growth of a Eucalyptus exserta forest in tropical China. Since there is no above ground input of C in this forest, microbial biomass (C_m_i_c) and soil organic C (C_o_r_g) are maintained by the below ground input only. By determining the maintenance requirement of the soil microflora, it should be possible to estimate the below ground production of this forest. To check this hypothesis the authors performed an experiment with labelled C. Since large scale production and field application of "1"4C labelled Eucalyptus litter were not feasible, 'naturally labelled' C_4 plant litter (Zea mays) was used. Maize litter has a #delta#"1"3C of -12.7 per mille as compared with a #delta#"1"3C of -30.7 per mille for Eucalyptus leaf litter. The "1"3C abundance is used to determine the amount of maize C in each of the soil layers. Investigations were made of how supplementation of the soil with litter ...

1990-10-01

431

Tunable far infrared laser spectroscopy of Van der Waals molecules in a planar supersonic jet expansion  

Energy Technology Data Exchange (ETDEWEB)

The gas phase high resolution spectroscopic study of weakly bound clusters can provide the information necessary to develop an intermolecular potential energy surface. This surface can then be used to better understand condensed phases. In this work, a tunable far infrared laser spectrometer is used to study weakly bound dimers produced in the newly developed continuous planar supersonic jet expansion apparatus. The water dimer is an extensively studied hydrogen bonded dimer. It undergoes several tunneling motions which result in splittings and perturbations of the rovibrational energy levels. A review is presented of much of the experimental and theoretical work done on water dimer, including a description of the combined fit of all the high resolution spectroscopic results by Coudert and Hougen. Also included is a discussion of the measurement of the K = 1 lower {yields} K = 2 lower band performed using the tunable far infrared laser/planar jet apparatus. The ...

1990-12-01

432

Total suspended matter observation in the Pearl River estuary from in situ and MERIS data.  

Science.gov (United States)

Based on the cruise data collected in the Pearl River estuary (PRE) in May 2008, an empirical two-band model by using the ratio of R (rs) at 629 and 671 nm was established to retrieve total suspended matter (TSM) concentration with the determination coefficient (R(2)) of 0.854, mean relative error (MRE) of 7.483%, and root-mean-square error (RMSE) of 1.295 mg L(?-?1). To match with medium resolution imaging spectrometer (MERIS) bands, in situ remote sensing reflectance was re-sampled to the bandwidth of 10 nm. The relationship between TSM and re-sampled R (rs) at 620 nm (MERIS band 6) and 665 nm (MERIS band 7) are obtained (R(2) = 0.748, RMSE = 1.697 mg L(?-?1), MRE = 8.785%, n = 13). Additionally, to map the spatial distribution of TSM in the PRE, MERIS level_1B data were calibrated using a multiple linear regression model based on in situ R (rs). Another dataset collected in the PRE in January 2004 was used to validate the two-band model and also applied to map ...

2010-09-01

433

Thermal stability of nanocomposite CrC/a-C:H thin films  

International Nuclear Information System (INIS)

The thermal stability of low-friction Me-C/a-C:H coatings is important for their potential applications in the tool and automotive industry. Recently we showed that CrC _x/a-C:H coatings prepared by unbalanced magnetron sputtering of a Cr target in Ar + CH_4 glow discharges exhibit a nanocomposite structure where metastable fcc CrC nanocrystals are encapsulated by an a-C:H phase. Here, we present the structural evolution of these nanocomposite CrC/a-C:H coatings during annealing. High-temperature X-ray diffraction in vacuum and differential scanning calorimetry (DSC) combined with thermo-gravimetric analysis in Ar atmosphere indicate decomposition of the formed metastable fcc CrC phase and subsequent formation of Cr_3C_2 and Cr_7C_3 and structural transformation of the a-C:H matrix phase towards higher sp"2 bonding contents at temperatures above 450 deg. C. Combined DSC and mass spectrometer analysis as well as elemental profiling after annealing in vacuum by ...

2007-05-07

434

The calibration of sub-Coulomb heavy ion proton transfer reactions  

Energy Technology Data Exchange (ETDEWEB)

Measurements were made of the cross sections for the /sup 27/Al(/sup 16/O,/sup 15/N)/sup 28/Si, /sup 89/Y(/sup 15/N,/sup 16/O)/sup 88/Sr and /sup 89/Y(/sup 27/Al,/sup 28/Si)/sup 88/Sr reactions at energies near and below the Coulomb barrier. The first reaction required separate measurements of the transfer to elastic cross section ratio for particular charge states, the charge state distribution for /sup 27/Al and /sup 28/Si ions, and the absolute elastic scattering cross section for the /sup 27/Al + /sup 16/O system. The ratio measurement required the combined use of two relatively new scientific instruments: the momentum filter and the Bragg curve spectrometer. The latter two transfer measurements were performed using the same setup involving surface barrier detectors at backward angles. Additional elastic scattering data for the /sup 15/N + /sup 28/Si, /sup 89/Y + /sup 15/N, /sup 89/Sr + /sup 27/Al, and /sup 88/Sr + /sup 28/Si systems was collected to provide ...

1987-01-01

435

Structures and properties of fluorinated amorphous carbon films  

International Nuclear Information System (INIS)

Fluorinated amorphous carbon (a-C:F) films were deposited by radio frequency bias assisted microwave plasma electron cyclotron resonance chemical vapor deposition with tetrafluoromethane (CF_4) and acetylene (C_2H_2) as precursors. The deposition process was performed at two flow ratios R=0.90 and R=0.97, where R=CF_4/(CF_4+C_2H_2). The samples were annealed at 300 deg. C for 30 min. in a N_2 atmosphere. Both Fourier transform infrared and electron spectroscopy for chemical analyzer were used to characterize the a-C:F film chemical bond and fluorine concentration, respectively. A high resolution electron energy loss spectrometer was applied to detect the electronic structure. The higher CF_4 flow ratio (R=0.97) produced more sp"3 linear structure, and it made the a-C:F film smoother and softer. A lifetime of around 0.34 #mu#s and an energy gap of #approx#2.75 eV were observed in both the as-deposited and after annealing conditions. The short carriers lifetime in ...

2004-07-01

436

SIMS analysis of silicon on insulator structures formed by high-dose O/sup +/ implantation into silicon  

Energy Technology Data Exchange (ETDEWEB)

Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ions were monitored which provided a high ...

1983-12-15

437

Research on laser welding of cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft  

Energy Technology Data Exchange (ETDEWEB)

Exploratory experiments of laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft were conducted. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. The corresponding mechanisms were discussed in detail. Results showed that the laser-welded seam had non-equilibrium solidified microstructures consisting of FeCr{sub 0.29}Ni{sub 0.16}C{sub 0.06} austenite solid solution dendrites as the dominant and some fine and dispersed Ni{sub 3}Al {gamma}' phase and Laves particles as well as little amount of MC short stick or particle-like carbides distributed in the interdendritic regions. The average microhardness of the welded seam was relatively uniform and lower than that of the base metal due to partial ...

2008-04-03

438

Research on laser welding of cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft  

International Nuclear Information System (INIS)

Exploratory experiments of laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft were conducted. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. The corresponding mechanisms were discussed in detail. Results showed that the laser-welded seam had non-equilibrium solidified microstructures consisting of FeCr_0_._2_9Ni_0_._1_6C_0_._0_6 austenite solid solution dendrites as the dominant and some fine and dispersed Ni_3Al #gamma#' phase and Laves particles as well as little amount of MC short stick or particle-like carbides distributed in the interdendritic regions. The average microhardness of the welded seam was relatively uniform and lower than that of the base metal due to partial dissolution and ...

2008-04-03

439

RED NUGGETS AT z #approx# 1.5: COMPACT PASSIVE GALAXIES AND THE FORMATION OF THE KORMENDY RELATION  

International Nuclear Information System (INIS)

We present the results of Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) imaging of a sample of 19 high-mass passively evolving galaxies with 1.2 < z < 2, taken primarily from the Gemini Deep Deep Survey (GDDS). Around 80% of galaxies in our GDDS sample have spectra dominated by stars with ages #approx#>1 Gyr. Our rest-frame R-band images show that most of these objects have compact regular morphologies which follow the classical R "1"/"4 law. These galaxies scatter along a tight sequence in the size versus surface brightness parameter space which defines the Kormendy relation. Around one-third (3/10) of the massive red objects in the GDDS sample are extraordinarily compact, with effective radii under 1 kpc. Our NICMOS observations allow the detection of such systems more robustly than is possible with optical (rest-frame UV) data, and while similar systems have been seen at z #approx#> 2, this is the first time such systems have been ...

2009-04-10

440

Purification of CH{sub 3}Cl from CH{sub 3}I using cold trap with sealed 2,2,4-trimethylpentane for {delta}{sup 37}Cl measurement  

Energy Technology Data Exchange (ETDEWEB)

A cryogenic separation method of chloromethane (CH{sub 3}Cl) from methyl iodide (CH{sub 3}I) for {delta}{sup 37}Cl measurement with isotope ratio mass spectrometer is described. A cold trap with sealed 2,2,4-trimethylpentane (TMP) as the cryogen is used in this method. CH{sub 3}Cl can be separated from CH{sub 3}I at the TMP melting point (-107 deg. C) based on the difference in the vapor pressure between CH{sub 3}Cl (322.6 Pa) and CH{sub 3}I (lower than 1.3 Pa) at -107 deg. C. After two-step separation processes, the yields of CH{sub 3}Cl purified from CH{sub 3}Cl-CH{sub 3}I mixture are 96-101%, and the difference between the {delta}{sup 37}Cl{sub original} and {delta}{sup 37}Cl{sub Afterseparation} is from -0.06 to +0.06 per mille (0.01 {+-} 0.04 per mille ). These results suggest that CH{sub 3}Cl is completely separated from CH{sub 3}I with no change of {delta}{sup 37}Cl value. This method using the cold trap with sealed TMP is very safe and not harmful, because ...

2006-01-05

441

Products of the Benzene + O(3P) Reaction  

Science.gov (United States)

The gas-phase reaction of benzene with O(3P) is of considerable interest for modeling of aromatic oxidation, and also because there exist fundamental questions concerning the prominence of intersystem crossing in the reaction. While its overall rate constant has been studied extensively, there are still significant uncertainties in the product distribution. The reaction proceeds mainly through the addition of the O atom to benzene, forming an initial triplet diradical adduct, which can either dissociate to form the phenoxy radical and H atom, or undergo intersystem crossing onto a singlet surface, followed by a multiplicity of internal isomerizations, leading to several possible reaction products. In this work, we examined the product branching ratios of the reaction between benzene and O(3P) over the temperature range of 300 to 1000 K and pressure range of 1 to 10 Torr. The reactions were initiated by pulsed-laser photolysis of NO2 in the presence of benzene and helium buffer in a ...

2009-12-21

442

Ozone Layer Observations  

Science.gov (United States)

The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure the ozone vertical distribution, the SBUV and SAGE (Stratospheric ...

2002-01-01

443

Magnetic excitations in R_2PdSi_3 studied by inelastic neutron scattering  

International Nuclear Information System (INIS)

R_2PdSi_3 compounds have been found to exhibit rich magnetic phenomena arising from the interplay between RKKY interaction, crystal electric field effects and geometric frustration due to the derived hexagonal AlB_2 structure. The observed crystallographic superstructure further complicates the CEF level scheme. Inelastic neutron scattering measurements on single crystals of Tm_2PdSi_3 and Er_2PdSi_3 have been performed at the cold triple axis spectrometer PANDA in FRM-II. Both compounds order antiferromagnetically at T_N=7 K and 2.1 K respectively; Er_2PdSi_3 undergoes a second phase transition at T_2=2 K. Several low lying CEF excitations (below 10 meV) were observed. The intensity of the lowest excitation show strong directional dependence (in HK0 plane for Er_2PdSi_3 and in HHL plane for Tm_2PdSi_3), from which the details of the transitional matrix could be deduced. Measurements in magnetic fields up to 13 T show Zeeman splitting of the CEF excitations. In ...

2009-03-22

444

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell to the total M shell x-ray emission were evaluated and it is seen that the shift of vacancies from L_3 ...

445

Infrared stimulated luminescence and phosphorescence spectra of irradiated feldspars  

International Nuclear Information System (INIS)

A new high-sensitivity wide-bandwidth 1.25-5.5 eV (225-1000 nm) spectrometer has been constructed to measure luminescence emission spectra of minerals that are of interest for optical dating. Spectra of emission resulting from 1.43 eV (IR) excitation after #gamma#-irradiation are reported for 13 cut rock feldspars and 20 feldspar separates. Also reported are phosphorescence spectra following #gamma#-irradiation, and after 1.4 eV excitation. The main differences between the infrared stimulated luminescence spectra and the phosphorescence is the almost complete absence of the violet, 3.1 eV, and yellow-green, 2.2 eV, bands in the phosphorescence, and the presence of a green emission band centred at 2.7 eV in the phosphorescence following #gamma#-irradiation (but absent in the phosphorescence following 1.4 eV excitation). The red, 1.7 eV, band is present in all the phosphorescence spectra but is not always seen during 1.4 eV excitation. A band at #approx# 1.3 eV is ...

2003-11-26

446

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type enclosure and showed that a single window ...

447

High-precision Penning-Trap measurements of light-ion masses  

International Nuclear Information System (INIS)

The UW-Penning Trap Mass Spectrometer (PTMs) is ideally suited for high precision measurements of atomic masses throughout the periodic table upon using highly-stripped ions. However, at the present time, this device has been applied extensively to the light elements ("1H, "2H, "3H, "3He, "4He, "1"2C, "1"3C, "1"4N, "1"6O) due to their fundamental importance. Atomic masses follow immediately from a comparison with some multiply-charged carbon ion, after correcting for the lost electrons and their corresponding binding energies. For instance, the most recent C"5"+/C"6"+ comparison yielded a discrepancy of -0.30(33) ppb, limited only by the magnetic field instability for a 40-h run. The initial emphasis on hydrogen has now produced a 1-ppb value for the proton's atomic mass and similar work with deuterium has yielded a 2.5-ppb value for the neutron's atomic mass. However, the most significant result is the "3H-"3He mass difference = 18,590.1(17) eV which is determined ...

1993-04-12

448

HPLC-APCI-MS analysis of triacylglycerols (TAGs) in historical pharmaceutical ointments from the eighteenth century.  

Science.gov (United States)

The lipid fractions of residues from historical pharmaceutical ointments were analysed by reversed-phase liquid chromatography coupled with atmospheric pressure chemical ionization and mass spectrometer detection. The residues were contained in a series of historical apothecary jars, dating from the eighteenth century and conserved at the "Aboca Museum" in Sansepolcro (Arezzo, Italy) and at the pharmacy of the "Real Cartuja de Valldemossa" in Palma de Majorca (Spain). The analytical protocol was set up using a comparative study based on the evaluation of triacylglycerol (TAG) compositions in raw natural lipid materials and in laboratory-reproduced ointments. These ointments were prepared following pharmaceutical recipes reported in historical treatises and used as reference materials. The reference materials were also subjected to stress treatments in order to evaluate the modification occurring in the TAG profiles as an effect of ageing. TAGs were successfully ...

2011-06-29

449

First Light for MIRSI  

Science.gov (United States)

We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This system offers the unique ability to acquire both spectra and high-resolution, multi-wavelength ...

2001-12-01

450

Experimental investigation of the KLL Auger spectrum of "8"8Sr from the EC-decay of "8"8Y  

International Nuclear Information System (INIS)

According to the calculations, intensity of the KL_1L_2("3P_0) Auger transition should drastically increase with increasing atomic number Z due to the relativistic effects. However, this behavior was experimentally proved only for very few elements. A lack of enough precise experimental data in the atomic number region Z<45 does not enable one to distinguish between relativistic and non-relativistic approaches in this region. Thus for Z=38 the KL_1L_2("3P_0/"1P_1) intensity ratio was determined with relative uncertainty of 63 % in the only measurement with external excitation. Here we present results of our investigation of the KLL Auger electron spectrum of "8"8Sr generated in the EC decay of "8"8Y (T_1_/_2= 106.6 d). Electron spectra were measured with the 11 eV instrumental resolution using a combined electrostatic spectrometer. The present value of the KL_2L_3("1D_2) absolute transition energy in Sr is higher by 7.4 eV (i.e. more than 3#sigma#) then that ...

2007-06-04

451

Excitation function of "5"9 Co (n, 2n) "5"8 Co process in the energy range 13.9-14.7 MeV  

International Nuclear Information System (INIS)

The objective of the study is to measure the neutron cross sections for the "5"9 Co (n, 2n) "5"8 Co reaction around the 14 MeV energy region. Neutron activation cross section for almost all the nuclei, mostly in the medium energy region e.g., 7 to 20 MeV are reported in literature. Neutron cross section data around 14 MeV is of immense importance for the design of D + T fusion reactors. The accuracy of the cross section data at this energy region is a requirement for correct prediction of reactor parameters e.g., tritium breeding, nuclear heating, induced activity, etc. In order to perform the experiment, the Co-sample sandwiched in Ni foils was irradiated employing the J-25 Neutron Generator at the AERE, Savar, Dhaka. After irradiation, the counting was done by the activation technique using a high resolution Hp Ge gamma ray spectrometer. The gamma ray spectra was analyzed in a Canberra series-40 Multi-channel Analyzer. Calculations for cross sections were done at ...

452

Dissimilar autogenous full penetration welding of superalloy K418 and 42CrMo steel by a high power CW Nd:YAG laser  

Energy Technology Data Exchange (ETDEWEB)

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of {gamma}-FeCr{sub 0.29}Ni{sub 0.16}C{sub 0.06} austenite solid solution dendrites as the ...

2007-06-30

453

Dissimilar autogenous full penetration welding of superalloy K418 and 42CrMo steel by a high power CW Nd:YAG laser  

International Nuclear Information System (INIS)

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of #gamma#-FeCr_0_._2_9Ni_0_._1_6C_0_._0_6 austenite solid solution dendrites as the dominant ...

2007-06-30

454

Dissimilar autogenous full penetration welding of superalloy K418 and 42CrMo steel by a high power CW Nd:YAG laser  

Science.gov (United States)

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of ?-FeCr0.29Ni0.16C0.06 austenite solid solution dendrites as the dominant and very small ...

2007-06-01

455

Decay behaviors of H{sub 2}{sup -} anions in solid parahydrogen. Effect of nuclear spins on chemical reactions  

Energy Technology Data Exchange (ETDEWEB)

Decay processes of H{sub 2}{sup -} anions in {gamma}-rays-irradiated solid parahydrogen were studied by using ESR spectrometer. The following interesting results were obtained. First, the initial amount of ortho-H{sub 2}{sup -} anions in the {gamma}-irradiated solid parahydrogen was three times as large as those of para-H{sub 2}{sup -} anions. Second, the amount of para-H{sub 2}{sup -} anions decreases faster than that of ortho-H{sub 2}{sup -} anions upon storage of the irradiated samples at 4.2 K. Third, the decay rate of H{sub 2}{sup -} anions is accelerated by the addition of D{sub 2} molecules. Forth, H{sub 2}{sup -} anions at 2.2 K decay faster than at 4.2 K. According to the parity conservation rule in a homonuclear diatomic molecule, the energy of ortho-H{sub 2}{sup -} anions at the ground state is lower than that of para-H{sub 2}{sup -} anions, whereas that of ortho-H{sub 2} molecules is higher than that of para-H{sub 2} molecules at low temperatures. The ...

1996-11-01

456

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...

2006-03-15

457

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

International Nuclear Information System (INIS)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are collected with a ...

2006-03-01

458

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and elemental distribution ...

2005-06-11

459

Carbon dioxide absorption of He--Ne laser radiation at 4. 2. mu. m: characteristics of self and nitrogen broadened cases  

Energy Technology Data Exchange (ETDEWEB)

A laser resonance absorption spectrometer is used to investigate the characteristics of both self and nitrogen collision broadened carbon dioxide in resonance with He--Ne laser radiation at 4.2 ..mu..m. The absorption coefficient in these broadening conditions has contributions from the R(28) to R(34) absorption lines of the ..nu../sub 3/ CO/sub 2/ spectrum. The Fletcher-Powell optimization method is used to reduce the raw absorption data and to find the best value average collision broadening coefficient and laser emission frequency for a Lorentzian line shape model of the contributing lines. Pure carbon dioxide absorption in a pressure range of from 0.0016 atm (1.25 Torr) to 0.33 atm (250 Torr) is described well by the model with an average self broadening coefficient of 0.084 +- 0.008 cm/sup -1/ atm/sup -1/ for laser frequencies located at either 2370.591 +- 0.020 cm/sup -1/ or 2371.135 +- 0.019 cm/sup -1/. Nitrogen broadened carbon dioxide in the total pressure ...

1989-03-01

460

Calibration free laser-induced breakdown spectroscopy of oxide materials  

Energy Technology Data Exchange (ETDEWEB)

The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse duration {approx} 6 ns) ablation was performed in air. The ...

2010-08-15

461

CO{sub 2} bands in the 3350 - 3700 cm{sup {minus}1} spectral region: Ro-vibrational constants and absolute intensities  

Energy Technology Data Exchange (ETDEWEB)

Spectroscopic constants and absolute intensities from more than 2150 transitions belonging to 52 bands of 7 isotopic species of carbon dioxide have been determined using a multispectrum nonlinear least-squares fitting technique. The spectral data (0.01 cm{sup -1} resolution) were obtained at room temperature and low pressure (<10 Torr) using the McMath-Pierce Fourier transform spectrometer of the National Solar Observatory on Kitt Peak, Arizona. A natural sample of carbon dioxide with absorption path lengths between 24 and 385m were used in recording the spectra. The first measurements have been made of the theoretically predicted 2v{sub 2}{sup 2} 2+v{sub 3} {open_quotes}forbidden{close_quotes} band of {sup 12}CO{sub 2}. Two bands which have not been predicted so far, one belonging to {sup 13}CO{sub 2} and the other to {sup 13}C{sup 16}O{sup 18}O, have been identified. The measured line intensities obtained for each band have been analyzed to determine the ...

1995-12-31

462

Automated ARXPS goniometer/diffractometer. Final report, April 1995--March 1997  

Energy Technology Data Exchange (ETDEWEB)

This award provided for an automated computer-controlled goniometer/diffractometer/manipulator with hot and cold stages and data acquisition system that was interfaced with the high resolution Scienta ESCA-300 X-ray photoelectron spectrometer at Lehigh University. The automation allows angular dependent X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS) data to be accurately and rapidly collected without the very time-consuming and labor-intensive manual method that was previously required. It also provides for automated multi-sample analyses, collecting both wide survey scans and selected binding energy range analyses, with complete computer control and data storage. This allows 24 hour data collection without requiring the continuous presence of operators. The overall result is a greater productivity for the XPS laboratory, approximately doubling the output of the laboratory. While the automated computer-controlled ...

1998-07-01

463

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved x-ray-emitting zones for all the anodes were captured by a pinhole-based x-ray imaging camera and the images were scanned for different gray levels by using a MATLAB computing ...

2006-01-01

464

Analysis of Elements in The Baltic Sea Sediment by Using Gamma Spectrometry  

International Nuclear Information System (INIS)

We have done analysis of elements in the Baltic sea sediment by using gamma spectrometry in neutron activation analysis Goal of the analysis is to determine the rate of morsel elements which is contained in the Baltic sea sediment. Sample of the Baltic sea Sediment (IAEA-SED-1), Standard of Reference Material (SRM) 1646 Estuarine Sediment and Standard Ce, Fe, Sc, and Co are put into vial of capsule rabbit, then irradiated together for 30 minutes in rabbit facility Multi Purpose Reactor at power of 25 MW and then cooled for one week. Next sample, standard, and SRM which have irradiated, each is cut for 30 minutes using gamma spectrometer. Result of analysis of rate of elements Ce, Fe, Sc and Co in the baltic sea sediment successively equal to 141.20 ppm, 5.91 %, 14.88 ppm, and 19.59 ppm. Result of analysis in SRM Estuarine sediment successively equal to 96.60 ppm, 3.21 %, 10.25 ppm, and 9.63 ppm. Result of this analysis if compared to the value contained in SRM ...

2007-04-01

465

An experimental investigation of H{sub 2} emissions of a 2004 heavy-duty diesel engine supplemented with H{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen (H{sub 2}) emissions characteristics of H{sub 2}-diesel dual fuel engine were measured using a 2004 turbocharged heavy-duty diesel engine with H{sub 2} supplemented into the intake air. The emissions of H{sub 2} were measured using an Electron Pulse Ionization (EPI) Mass Spectrometer (MS). The effect of the amount of H{sub 2} added, the engine load, and diesel fuel flow rates on the emissions of H{sub 2} and its combustion efficiency in the engine were investigated. The addition of H{sub 2} under high load operation was notable for its ability to obtain high H{sub 2} combustion efficiency and improve brake thermal efficiency. However, the addition of H{sub 2} at low load resulted in high emissions of H{sub 2} due to the failure to initiate and support a sufficiently vigorous flame for the complete combustion of H{sub 2} present outside the diesel spray plume. The maximum H{sub 2} emissions of 1.4% (volume in dry exhaust gas) were observed with the addition ...

2010-10-15

466

A REAL-TIME COAL CONTENT/ORE GRADE (C2OC) SENSOR  

Energy Technology Data Exchange (ETDEWEB)

This is the final report of a three year DOE funded project titled ''A real-time coal content/ore grade (C{sub 2}OG) sensor''. The sensor, which is based on hyperspectral imaging technology, was designed to give a machine vision assay of ore or coal. Sensors were designed and built at Resonon, Inc., and then deployed at the Stillwater Mining Company core room in southcentral Montana for analyzing platinum/palladium ore and at the Montana Tech Spectroscopy Lab for analyzing coal and other materials. The Stillwater sensor imaged 91' of core and analyzed this data for surface sulfides which are considered to be pathfinder minerals for platinum/palladium at this mine. Our results indicate that the sensor could deliver a relative ore grade provided tool markings and iron oxidation were kept to a minimum. Coal, talc, and titanium sponge samples were also imaged and analyzed for content and grade with promising results. This research has led ...

2005-04-01

467

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the dosimetric properties of the chip cards, the raw material of the globe ...

468

Preliminary study of the {alpha} ratio measurement, ratio of the neutron capture cross section to the fission one for {sup 233}U, on the PEREN platform. Development and study of the experimental setup; Etude preliminaire de la mesure du rapport {alpha}, rapport de la section efficace moyenne de capture sur celle de fission de l'{sup 233}U, sur la plateforme PEREN. Developpement et etude du dispositif experimental  

Energy Technology Data Exchange (ETDEWEB)

Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...

2007-12-15

469

Distribution of naturally occurring radionuclides activity concentration in East Malaysian marine sediment  

Energy Technology Data Exchange (ETDEWEB)

Studies of naturally occurring radioactive materials (NORM) distribution of {sup 226}Ra, {sup 228}Ra and {sup 40}K in East Malaysia were carried out as part of a marine coastal environment project. The results of measurements will serve as baseline data and background reference level for Malaysia coastlines. Sediments from 21 coastal locations and 10 near shore locations were collected for analyses. The samples were dried, finely ground, sealed in a container and stored for a minimum of 30 days to establish secular equilibrium between {sup 226}Ra and {sup 228}Ra and their respective radioactive progenies. They were counted using a high-purity germanium (HPGe) spectrometer covering the respective progeny energy peak. For {sup 40}K, the presence of this was measured directly via its 1460 keV energy peak. The concentration of {sup 226}Ra, {sup 228}Ra and {sup 40}K in samples obtained from coastal Sarawak ranged between 23 and 41 (mean 30{+-}2) Bq/kg, 27 and 45 (mean ...

2009-04-15

470

Delayed neutron energy spectra following fast fission of "2"3"8U  

International Nuclear Information System (INIS)

Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to 450 keV and Bicron BC 501 liquid ...

471

Coupled effects of the precipitation of secondary species on the mechanical behaviour and chemical degradation of concretes; Les effets couples de la precipitation d'especes secondaires sur le comportement mecanique et la degradation chimique des betons  

Energy Technology Data Exchange (ETDEWEB)

Sulfate attack of cement-based materials remains an important problem for the durability assessment of containers and disposal engineering barriers dedicated to the long-term storage of radioactive wastes since underground water which may reach these elements contains small quantities of sulfates (7-31 mmol/1). This work contributes to the study of sulfate-induced damage mechanisms, to their understanding and modelling. The experimental phases of this study aimed at the understanding of the different physico-chemical phenomena involved during an external sulfate attack at following their evolution and their impact on the transport and mechanical properties of the material. Leaching experiments in pure water and in a solution of sodium sulfate (with a sulfate content of 15 mmol/1), have been performed simultaneously on OPC paste (w/c 0,4)in order to allow a comparison of test results. The frequent analysis of the leachant has shown a consumption of sulfate ions by the matrix, ...

2002-06-01

472

Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging  

International Nuclear Information System (INIS)

Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope ...

473

Application of photogrammetry, remote sensing and GIS in the environmental monitoring of the Deutsche Steinkohle AG; Einsatz von Photogrammetrie, Fernerkundung und GIS im Umweltmonitoring der Deutschen Steinkohle AG  

Energy Technology Data Exchange (ETDEWEB)

Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent scatterer technology (here: the use of the ...

2006-03-15

474

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are used for charged particle identification ...

2004-11-01

475

Aerosol composition, chemistry, and source characterization during the 2008 VOCALS Experiment  

Energy Technology Data Exchange (ETDEWEB)

Chemical composition of fine aerosol particles over the northern Chilean coastal waters was determined onboard the U.S. DOE G-1 aircraft during the VOCALS (VAMOS Ocean-Cloud-Atmosphere-Land Study) field campaign between October 16 and November 15, 2008. SO42-, NO3-, NH4+, and total organics (Org) were determined using an Aerodyne Aerosol Mass Spectrometer, and SO42-, NO3-, NH4+, Na+, Cl-, CH3SO3-, Mg2+, Ca2+, and K+ were determined using a particle-into-liquid sampler-ion chromatography technique. The results show the marine boundary layer (MBL) aerosol mass was dominated by non- sea-salt SO42- followed by Na+, Cl-, Org, NO3-, and NH4+, in decreasing importance; CH3SO3-, Ca2+, and K+ rarely exceeded their respective limits of detection. The SO42- aerosols were strongly acidic as the equivalent NH4+ to SO42- ratio was only ~0.25 on average. NaCl particles, presumably of sea-salt origin, showed chloride deficits but retained Cl- typically more than half the ...

2010-03-15

476

Activities and activity ratios of U and Ra radioisotopes in drinking wells, springs and tap water samples in Morocco  

International Nuclear Information System (INIS)

Radiochemical results ("2"3"4U, "2"3"8U, "2"2"6Ra and "2"2"8Ra activities; "2"3"4U/"2"3"8U, "2"2"8Ra/"2"2"6Ra and "2"2"6Ra/"2"3"8U activity ratios) are reported for 31 drinking water samples collected from 8 wells, 12 hot mineral springs, 5 cold springs, and 6 tap water samples. Activities of the Ra isotopes were measured by gamma spectrometry using a low background and high efficiency well type germanium detector. The U isotopes were counted in an alpha spectrometer. The results show that "2"3"8U activity varies between 4.46 and about 308 mBq l"-"1 in wells, 0.59 and 17.88 mBq l"-"1 in hot springs, 2.19 and 3.21 mBq l"-"1 in cold springs, and between 2.5 and 15.70 mBq l"-"1 in tap water samples. "2"3"4U/"2"3"8U activity ratio is generally higher than 1 which is the equilibrium activity ratio value in closed systems. It varies in the ranges 0.79-2.11 in wells, 0.97-7.39 in hot springs, 2.53-8.30 in cold springs, and 1.14-3.35 in tap water. Unlike well waters, ...

477

/sup 18/O isotope effect in carbon-13 nuclear magnetic resonance spectroscopy. Part 8. Oxygen exchange of 2,4,6-trimethylpyrylium cation  

Energy Technology Data Exchange (ETDEWEB)

The rate of the oxygen-exchange reaction in an aqueous solution of a heterocyclic oxygen compound, 2,4,6-trimethylpyrylium perchlorate, was quantitated. The /sup 18/O isotope effect in /sup 13/C NMR spectroscopy affords a direct, continuous, and relatively simple analysis of the reaction and was used to obtain data on the incorporation of /sup 18/O from solvent H/sub 2//sup 18/O into the pyrylium salt. Due to the low solubility of this salt in aqueous solutions, 2,4,6-trimethyl(2-/sup 13/C)pyrylium perchlorate and 2,4,6-trimethyl(2,6-/sup 13/C/sub 2/)pyrylium perchlorate were synthesized to facilitate the acquisition of the data on an NTC-200 spectrometer operating at 50.31 MHz. Upon incorporation of /sup 18/O into the pyrylium salt, the /sup 13/C NMR signal of the directly bonded carbon atom is shifted upfield 0.038 ppm. A /sup 13/C isotope effect is also detected in the doubly /sup 13/C-enriched pyrylium salt where the /sup 13/C NMR signal for /sup 13/C-O-/sup ...

1984-12-12

478

Temperature-dependent properties of semiconductor quantum dots in coherent regime; Temperaturabhaengige Eigenschaften einzelner Halbleiter-Quantenpunkte im Kohaerenten Regime  

Energy Technology Data Exchange (ETDEWEB)

Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). Transitions between the relevant levels can be ...

2009-10-15

479

Structure, morphology and hydrogen storage properties of composites prepared by ball milling Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub 0.3}V{sub 0.3} with La-Mg-based alloy  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen storage alloy composites La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5}(x=0,5,10) were prepared by ball milling method. Their structures, morphologies and the hydrogen storage characteristics were intensively studied in the present work. It was found that the bulk of composites maintained the hexagonal C14 Laves phase structure after ball milling with additional La-Mg-based alloy for two hours. Scanning electron microscopy (SEM) observations revealed that the average size of Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub 0.3}V{sub 0.3} and La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5} particles were reduced to several hundred nanometers after ball milling process. Energy dispersive X-ray spectrometer (EDS) patterns of the composites showed that the La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5} phase was uniformly distributed on the surface of Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub ...

2007-10-15

480

Review of JT-60U experimental results from February to October, 1999  

International Nuclear Information System (INIS)

In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the pedestal ion temperature due to strong gas was found cause ...

1994-06-01

481

Radioactive targets for neutron-induced cross section measurements  

Science.gov (United States)

Measurements using radioactive targets are important for the determination of key reaction path ways associated with the synthesis of the elements in nuclear astrophysics (sprocess), advanced fuel cycle initiative (transmutation of radioactive waste), and stockpile stewardship. High precision capture cross-section measurements are needed to interpret observations, predict elemental or isotopical ratios, and unobserved abundances. There are two new detector systems that are presently being commissioned at Los Alamos National Laboratory for very precise measurements of (n,{gamma}) and (n,f) cross-sections using small quantities of radioactive samples. DANCE (Detector for Advanced Neutron-Capture Experiments), a 4 {pi} gamma array made up of 160 BaF{sub 2} detectors, is designed to measure neutron capture cross-sections of unstable nuclei in the low-energy range (thermal to {approx}500 keV). The high granularity and high detection efficiency of DANCE, combined with the high TOF-neutron ...

2004-01-01

482

Potential of sub-ablative pulsed CO{sub 2} laser irradiation on inhibition of artificial caries-like lesion progress in bovine dental enamel; Potencial de inibicao da progressao da carie artificial por irradiacao sub-ablativa com laser de CO{sub 2} pulsado em esmalte dental bovino  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to investigate whether sub-ablative pulsed C0{sub 2} laser (1 0,6 {mu}m) irradiation is capable of reducing the susceptibility of the dental enamel to demineralization, and thus achieving a potential caries-protective effect. The crowns of 51 bovine front teeth, embedded in acrylic resin and polished until exposure of flat enamel surface, were used. The samples were cut in cubes of 10x10 mm, and totally coated with acid-resistant nail varnish, except for an enamel exposed window of 16 mm square. Three groups (n=17) were obtained: control group (CG) not irradiated; group laser A (LA) and group laser B (LB) where the samples were irradiated. The conditions were 60 mJ, 100 Hz, 0,3 J/cm{sup 2} for LA and 135 mJ, 10 Hz, 0,7 J/cm{sup 2} for LB. Two samples of each group were submitted to SEM analysis and fifteen to demineralization in 3 ml acetate buffer solution (0,1 mol/L) with pH 4,5 for 24h at 37 deg C, with regular agitation. After the specimens were removed ...

2005-07-01