WorldWideScience
1

CERN se plantea adelantar asueto para reiniciar experimento en abril  

CERN Document Server

CERN se plantea adelantar asueto para reiniciar experimento en abril

2008-01-01

2

show expanded view - NAI: Ask an Astrobiologist  

Science.gov (United States)

I understand that you cannot answer truthfully because of the the janap 146e otherwise you would be commiting treason but please give a more intelligent ...

3

Suzanne Baldwin ? Profile ? Directory ? NASA Astrobiology  

Science.gov (United States)

The unified web presence for the NASA Astrobiology Program which includes the NASA Astrobiology Institute (NAI), Astrobiology Science and Technology for ...

4

Pharmacokinetic parameters for thallium (I)-ions in man  

Energy Technology Data Exchange (ETDEWEB)

The pharmacokinetics of Tl/sup +/ were studied in 9 patients who underwent myocardial scintigraphy with /sup 201/Tl/sup +/. The time course of the /sup 201/Tl/sup +/ concentration fitted to an open two-compartment model. Using previously published dialysance values the influence of hemodialysis on Tl/sup +/ elimination was calculated. Hemodialysis in Tl/sup +/ intoxications should be moderately effective.

1983-05-01

5

Regulation of Na(+)-K+ pump activity in contracting rat muscle.  

UK PubMed Central (United Kingdom)

1. In rat soleus muscle, high frequency electrical stimulation produced a rapid increase in intracellular Na+ (Na+i) content. This was considerably larger in muscles contracting without developing tension...Full Text Available

1997-09-15

6

An analytic representation of the radial distribution of dose from energetic heavy ions in water, Si, LiF, and NaI  

International Nuclear Information System (INIS)

An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.

1989-09-01

7

As time goes by? The fallacy of thrombolysis in STEMI networks  

British Library Electronic Table of Contents (United Kingdom)

Primary percutaneous coronary intervention (PPCI) is superior to thrombolysis (TL) as reperfusion therapy in ST-elevation myocardial infarction (STEMI). TL is a rapidly available, but semi-effective therapy (effective reperfusion in 50% of patients only), whereas PPCI is a potentially delayed, but highly effective therapy (effective reperfusion in >90%). Since TL loses its efficacy beyond 2?3?h after symptom onset, it is a significant reperfusion alternative to PPCI in early presenters only. The individual decision to treat an early presenter with PPCI or TL requires the evaluation of the time delay between potential start of TL or PPCI, the PCI-related delay (PRD). PRD is greatest, if TL is given in the prehospital setting. Until now, prehospital TL as the most rapidly available reperfusi...

2011-01-01

8

Excretion of para-aminohippurate in the isolated perfused rat kidney: net secretion and net reabsorption.  

UK PubMed Central (United Kingdom)

1. The excretion of para-aminohippurate (PAH) in the isolated perfused rat kidney was examined over a wide range of perfusate PAH concentrations (15 microM to 6 mM). PAH excretion increased steadily...Full Text Available

1988-03-01

9

Equilibrium and pre-equilibrium emissions in proton-induced reactions on "2"0"3","2"0"5Tl  

International Nuclear Information System (INIS)

In this study, the excitation functions for the reactions "2"0"3Tl(p, n)"2"0"3Pb, "2"0"5Tl(p, 3n)"2"0"3Pb, "2"0"3Tl(p, 2n)"2"0"2Pb, "2"0"5Tl(p, 4n)"2"0"2Pb, "2"0"3Tl(p, 3n)"2"0"1Pb, "2"0"5Tl(p, 5n)"2"0"1Pb, "2"0"3Tl(p, 4n)"2"0"0Pb and "2"0"5Tl(p, 6n)"2"0"0Pb have been calculated using pre-equilibrium and equilibrium reactions mechanisms. Calculated results based on hybrid model, geometry-dependent hybrid model and cascade-exciton model have been compared with the experimental data. (author)

2009-02-01

10

Infrared bleaching of the thermoluminescence of four feldspars  

International Nuclear Information System (INIS)

This paper studies the effect upon the thermoluminescence (TL) signal of four feldspar samples of exposing them to infrared stimulation, as occurs during infrared-stimulated luminescence (IRSL) measurement. Together with pulse annealing measurements these results are used to show which part of the TL signal is removed by exposure to IR and which part is directly related to the IRSL signal that is observed. When the samples are preheated prior to measurement in order to remove any low-temperature (< 200"oC) TL signals, a linear relationship is observed between the amount of TL that is lost and the IRSL light sum that is produced. The IRSL light sum is consistently four times larger than the amount of TL that is lost. Three possible explanations are proposed for this, but no conclusive evidence could be obtained to support any of them. A close similarity is observed in the pulse ...

1995-06-01

11

Production of 'no-carrier-added' "2"0"1Tl  

International Nuclear Information System (INIS)

A procedure has been developed for producing a radiopharmaceutically pure ''no-carrier-added'' "2"0"1Tl. The procedure is based on irradiating enriched metallic thallium (> 96% "2"0"3Tl) targets with approx. 30 Mev protons, separating "2"0"1Pb by co-precipitation with SrSO_4 from sulphuric acid solution, and extracting "2"0"1Tl (after its in-growth) with butyl acetate from a hydrochloric solution. The average overall yield of "2"0"1Tl is approx. 92%. The radioactive concentration of the product exceeds 2 mCi/mL; radionuclide impurities-"2"0"0Tl <= 0.5%; "2"0"2Tl <= 0.1%; "2"0"3Pb <= 0.02%; inactive impurities (#mu#g/mL)-Tl < 2, Sr < 1, Fe < 0.25, Cu < 0.05; pH within the range 5-8. The product is sterile, apyrogenic, and suitable for clinical application. (author).

12

Non-linearity of pre-dose response and its effects on TL dating  

Energy Technology Data Exchange (ETDEWEB)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-15

13

Non-linearity of pre-dose response and its effects on TL dating  

International Nuclear Information System (INIS)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-01

14

Conversion of ortho-para H2O isomers in water and a jump in erythrocyte fluidity through a microcapillary at a temperature of 36.6?0.3?C  

British Library Electronic Table of Contents (United Kingdom)

A mechanism is proposed for the previously observed [1] jump in erythrocyte fluidity through a microcapillary 1.3 ?m in diameter at a temperature of 36.6?0.3?C. Our interpretation is based on the experimental evidence both for existence of ortho and para H2O isomers in water and on spin-selective interaction of proteins with para H2O isomers as hydration shells of biomolecules are being formed [2]. It is important that the formation of hydration shells of proteins and DNA in aqueous solutions is accompanied by an increase in the Brillouin shift to 0.4 cm?1 (?0.25 cm?1 in water), which points to the formation of icelike structures. We believe that the coincidence of the translational energy kT of the Brownian motion and the energy of the rotational quanta for the 313?202 transition of para ...

2009-01-01

15

NAI: Year 4 Annual Report - NASA Astrobiology Institute  

Science.gov (United States)

His talk was based on the suggestion that life on Earh has been a long but accelerating ..... a New Class of Submarine Hydrothermal System"; April 29, 2002 , ..... of media personnel, including radio, television, newspapers, and magazines. ...... "The Birth of Stars and Planets" (Denver Museum of Nature and Science ...

16

Separation of "2"0"3Pb from Tl_2O_3 target material using a hydrous zirconium oxide column with application to "2"0"1Tl preparation  

International Nuclear Information System (INIS)

Lead 203 has been used as a tracer for lead in the field of nuclear medicine for several years. It is produced in a cyclotron usually by proton or deuteron bombardment of a thallium target principally by the p,n or d,2n reaction on "2"0"3Tl or the p,3n or d,4n reaction on "2"0"5Tl. Several different methods have been reported for the separation of "2"0"3Pb from the thallium target. These generally involve a combination of precipitation and solvent extraction techniques. A new method has been developed for the separation of Pb from Tl using ion exchange chromatography over hydrous zirconium oxide (HZO). Lead is taken up by this inorganic ion exchanger at pH > 3 whereas Tl(I) is not. Lead can subsequently be eluted with acid of pH 1-1.5. The recovery of "2"0"3Pb has been approximately 75% and the Tl impurity level has not been in excess of 10 ppm. Reference is made to the ...

17

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO{sub 4}  

Energy Technology Data Exchange (ETDEWEB)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The ...

2005-10-15

18

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO_4  

International Nuclear Information System (INIS)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL ...

2005-10-01

19

Supersymmetric para boson-fermion oscillator systems and their spectra  

Energy Technology Data Exchange (ETDEWEB)

In this paper para boson-fermion supersymmetry is exemplified in simple oscillator systems. The parasupercharge satisfies the ordinary supersymmetry algebra. The parabosonic and parafermionic oscillators do not commute and the energy spectra are non-trivial for even the one level system. The authors calculate the partition functions and compare with those for the non-supersymmetric systems.

1991-07-20

20

Myocardial perfusion SPECT in patients after myocardial infarction: Comparison of "2"0"1Tl and dual-isotope protocol (rest "2"0"1Tl/stress "9"9"mTc tetrofosmin)  

International Nuclear Information System (INIS)

The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI

1998-08-01

21

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to ...

1991-06-01

22

Luminescence characteristics for the detection of radiation treatment of shellfish by using isolated minerals  

International Nuclear Information System (INIS)

Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray ...

23

Purification of cyclotron-produced {sup 203}Pb for labeling Herceptin  

Energy Technology Data Exchange (ETDEWEB)

A simple and rapid procedure was developed for the purification of cyclotron-produced {sup 203}Pb via the {sup 203}Tl(d,2n) {sup 203}Pb reaction. A Pb(II) selective ion-exchange resin, with commercial name Pb Resin from Eichrom Technologies, Inc., was used to purify {sup 203}Pb from the cyclotron-irradiated Tl target with excellent recovery of the enriched Tl target material. The purified {sup 203}Pb was used to radiolabel the monoclonal antibody Herceptin. The in vitro and in vivo properties of the {sup 203}Pb radioimmunoconjugate were evaluated.

2005-04-01

24

Luminescence characteristics of LiCaAlF6:Eu phosphor  

British Library Electronic Table of Contents (United Kingdom)

A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

2007-01-01

25

Thallium-201 yields and excitation functions for the lead radioactivities produced by irradiation of natural thallium with 15-60 MeV protons  

International Nuclear Information System (INIS)

Excitation functions, production yields and radionuclidic purities are described for "2"0"1Tl production by the "2"0"3Tl(p,3n) "2"0"1Pb #-># "2"0"1Tl and "2"0"5Tl(p,5n)"2"0"1Pb#->#"2"0"1Tl nuclear reactions. The yields (mCi g"-"1 cm"2/#mu#A-hr) of the parent "2"0"1Pb(9.4hr), as well as the radiocontaminants "2"0"0Pb(21.5hr), sup(202m)Pb(3.62 hr), "2"0"3Pb(52.1 hr) and sup(204m)Pb(1.115 hr) were measured by irradiating a stack of thin natural Tl foils with protons from the 76-in isochronous cyclotron at the Crocker Nuclear Laboratory. The "2"0"1Tl thick-target yield (mCi/#mu#A hr) was calculated for different target thicknesses and corresponding incident proton energies. The excitation functions for the "2"0"3Tl(p,3n)"2"0"1Pb and "2"0"5Tl(p,5n)"2"0"1Pb reactions were measured in the 15-60-MeV ...

26

Calculation of the knight shift in the system CaCdsub(1-x)Tlsub(x) by using relativistic APW wave functions  

International Nuclear Information System (INIS)

For the intermetallic system CaCdsub(1-x)Tlsub(x), 0 <= x <= 1, the Knight shift Ksub(s) of the Cd-NMR and the Tl-NMR were calculated as a function of x, Ksub(s) = Ksub(s)(x). The theoretical investigations were performed on the basis of relativistic augmented-plane-wave (RAPW) band-structure calculations for the boundary phases CaCd and CaTl respectively, and by using the rigid band model for the ternary phases. The density of states and the matrix elements of the relativistic hyperfine operator for electron states at the Fermi surface were calculated in detail. The obtained values were compared with nonrelativistic calculations. The effect of using different exchange potentials was studied for Ksub(s)(Tl). For the Cd-NMR the relativistic effects enhance the nonrelativistic results by a factor of about 1.4. The theoretical value for the Knight shift is smaller than the experimental one by a factor of 1.13. The band ...

27

Analysis of thermoluminescence glow curves of minerals sphene and epidote for radiation damage studies  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence (TL) properties of sphene and epidote are of interest in studies related to their radiation damage. Natural and artificially induced TL of these minerals has, therefore, been investigated. Both minerals exhibit complex glow curves with several overlapping peaks. The Tsub(m) -Tsub(STOP) thermal cleaning procedure has revealed three peaks in the ..gamma.. ray induced glow curve of each mineral. That these peaks obey second order kinetics was indicated by the continuously slanting structure of the Tsub(m)-Tsub(STOP) curve. The TL parameters E and s have been calculated using (i) the initial rise method, and (ii) the glow-peak shape method. In general, the values of E calculated by the first method are found to be higher than those from the second. The TL curve-fitting method is also applied in order to calculate these parameters and to serve as a cross-check on the results.

1986-01-01

28

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...

1999-07-01

29

Interactions of metal cations with anionic groups on the cell Wall of the macroalga vaucheria sp.  

Energy Technology Data Exchange (ETDEWEB)

The aim of this article was to investigate the interactions of metal cations in aqueous solutions with the biomass of the freshwater macroalga Vaucheria sp. This problem is important when elaborating new applications of biosorption, e.g. the production of mineral feed additives for livestock from the biomass of algae enriched with microelement ions. Potentiometric titration was applied as a quick and cheap screening test to search for new efficient biosorbents. It revealed a variety of functional groups capable of cation exchange on the macroalgal surface, including carboxyl, phosphate, hydroxyl or amino groups. Fourier transform infrared spectroscopy on natural and chromium-loaded Vaucheria sp. confirmed that carboxyl groups played a dominant role in the biosorption. The study also showed that Ca(II), Na(I), K(I), and Mg(II) ions were released from the biomass after biosorption of Cu(II), Mn(II), Zn(II), and Co(II) ions, indicating that ion exchange was a key ...

2010-06-15

30

Economic evaluation of geothermal projects; Evaluacion economica de proyectos geotermicos  

Energy Technology Data Exchange (ETDEWEB)

Fundamentals of economic evaluation of projects to produce electricity using geothermal energy are described. Steps to obtain the basic data used to calculate the present value and the internal rate of return are described. Finally, a criterion to make an economical evaluation to take the best investment selection is shown, applied to a geothermal project in the Los Azufres, field Michoacan, Mexico. [Espanol] En este articulo se describen los diferentes topicos que se desarrollan para llevar a cabo la evaluacion economica de un proyecto para generar electricidad, desde la recopilacion de datos hasta la obtencion de los indices necesarios para la toma de decisiones, y su aplicacion a un proyecto geotermoelectrico situado en el campo de Los Azufres, Michoacan, Mexico.

1995-01-01

31

Suppression of afterglow in CsI:Tl by co doping with Eu"2"+-II: Theoretical model  

International Nuclear Information System (INIS)

The mechanism for afterglow suppression in codoped CsI:Tl,Eu reported in the preceding paper was investigated by combined radioluminescence and thermoluminescence experiments. Model rate equations informed by these experiments were employed to simulate afterglow. It was found that codoping with europium introduces deep electron traps, with room-temperature glow peaks, that effectively scavenge the electrons from shallow traps associated with thallium, thus suppressing afterglow in the time domain of tens of milliseconds.

2006-03-15

32

SEM and EDXS analysis of the reaction products of compounds A[sub x]M[sub 6]X[sub 8] (A = Tl, K; M = V, Ti; X = S, Se) with I[sub 2]/CH[sub 3]CN and H[sub 2]O. [TlVS; TlVSe; TlTiS; TlTiSe; KVS; KVSe; KTiS; KTiSe  

Energy Technology Data Exchange (ETDEWEB)

The ternary transition metal chalcogenides A[sub x]M[sub 6]X[sub 8] (A = Tl, K; M = V, Ti; X = S, Se) build up a three dimensional framework with large hexagonal channels running parallel to the crystallographic c-axis. The electropositive elements thallium or potassium are confined within these channels. It is possible to remove the Tl or K atoms via a chemical redox reaction with an I[sub 2]/CH[sub 3]CN solution or with H[sub 2]O. Using SEM it is demonstrated that the host matrix V[sub 6]S[sub 8]'' is only slightly affected by the redox agent. In contrast the host matrix Ti[sub 6]Se[sub 8]'' of Tl[sub x]Ti[sub 6]Se[sub 8] reacts with the I[sub 2]/CH[sub 3]CN solution. The results of the EDXS analyses clearly show that the removal of the electropositive elements proceeds only along the large channels and not through the host matrix. (orig.)

1994-05-01

33

LiF:Mg, Cu, P TL detectors with adjustable energy responses  

Energy Technology Data Exchange (ETDEWEB)

When used for tissue-equivalent monitoring, the thermoluminescence material LiF:Mg, Cu, P shows an 'under-response' to low-energy photons. This paper explores a new way to increase its low-energy response effectively, and to make it adjustable to some extent, by adding elements with high Z{sub eff}. At the same time its excellent thermoluminescente (TL) performance is maintained. (author).

1991-11-14

34

Effects of ischemic-like insult on myocardial /sup 201/Tl accumulation  

Energy Technology Data Exchange (ETDEWEB)

Despite extensive clinical use of thallium-201 (/sup 201/Tl) for myocardial imaging, the effect of ischemia on myocardial accumulation and release of /sup 201/Tl independent of flow has not been fully defined. Therefore, myocardial accumulation of /sup 201/Tl in response to ischemic-like myocardial injury was assessed in vitro using the cultured fetal mouse heart preparation. Cultured fetal mouse hearts (n . 311) were subjected to injury simulating ischemia by deprivation of oxygen and oxidizable substrates for periods ranging from 15 minutes to 10 hours. The extent of irreversible injury was determined by the percentage of lactic dehydrogenase (LDH) lost from the hearts to the culture medium during recovery from injury. Injury was essentially reversible at 1 hour of insult. The fraction of /sup 201/Tl content in injured compared with control hearts was not significantly lower after 1 hour of insult. By ...

1983-04-01

35

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

36

Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite  

Energy Technology Data Exchange (ETDEWEB)

The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, ...

2006-08-15

37

Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite  

International Nuclear Information System (INIS)

The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, ...

2005-07-24

38

Un telescopio hecho de polvo lunar - Ciencia - Ciencia @ NASA  

Science.gov (United States)

13 Oct 2010 ... Cuando la resina se endureci?, Chen la coloc? en una c?mara de vac?o para depositar una delgada capa de aluminio reflector sobre la ...

39

Role of TRAIL and the pro-apoptotic Bcl-2 homolog Bim in acetaminophen-induced liver damage  

UK PubMed Central (United Kingdom)

Acetaminophen (N-acetyl-para-aminophenol (APAP), paracetamol) is a commonly used analgesic and antipyretic agent. Although considered safe at therapeutic doses, accidental or intentional...Full Text Available

2011-06-01

41

NASA - Informe De la Misi?n STS-126  

Science.gov (United States)

17 Nov 2008 ... El Analizador de Carbono Org?nico Total ser? usado para probar muestras que vendr?n del nuevo sistema de Recobre de Agua. ...

42

NASA - COLABORACI?N INNOVATIVA REVOLUCIONAR? LA SUPERCOMPUTACION ...  

Science.gov (United States)

3 Ago 2004 ... Siguiendo las recomendaciones de la OSTP, una parte del nuevo sistema estar? disponible en la base general para asegurar que toda la ...

43

I. Cyclopeptide Alkaloids; II. Phycocyanobilipeptides.  

Science.gov (United States)

Several examples of the 14-membered, para-bridged ring system of the cyclopeptide alkaloids have been synthesized via an active ester cyclization. The yield of monomeric cyclopeptide varied from 1 to 33% and was affected by the amino acid substitution pat...

1979-01-01

44

Greenversations » Invasive species  

Science.gov (United States)

(hidróxido de calcio o cal hidratada) como un plaguicida en un programa de cuarentena para controlar la especie invasora, el coquí. Hawai está preocupada de que estos...

2011-10-07

45

Greenversations » 2009 » January  

Science.gov (United States)

(hidróxido de calcio o cal hidratada) como un plaguicida en un programa de cuarentena para controlar la especie invasora, el coquí. Hawai está preocupada de que estos...

2011-10-07

46

Bait Insecticides and Hot Water Drenches Against the Little Fire Ant, Wasmannia auropunctata (Hymenoptera: Formicidae), ...  

Science.gov (United States)

... no individualmente sería un protocolo suficiente para la cuarentena contra la pequeña hormiga de fuego en plantas ... ...

47

A method for the optimal design of networks of drinking water distribution; Un metodo para el diseno optimo de redes de distribucion de agua potable  

Energy Technology Data Exchange (ETDEWEB)

A method to select, among several commercial diameter options, the most economic combination of pipeline networks is presented. These networks comply with the discharge conditions in the pipes and pressure in the knots. It is applied a static method for the hydraulics analysis of the Engineering Institute of the Universidad Nacional Autonoma de Mexico (UNAM) and an optimization technique to reduce the number of calculations. [Spanish] Se presenta un metodo para seleccionar, de entre varias opciones de diametros comerciales, la combinacion que forma la red de tuberias mas economica que satisface las condiciones de gasto en los tubos y de presion en los nudos de la misma. Para el analisis hidraulico se emplea un metodo estatico del Instituto de Ingenieria de la Universidad Nacional Autonoma de Mexico (UNAM) y se aplica una tecnica de optimacion para reducir el numero de calculos y alcanzar la solucion.

1998-12-01

48

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

49

First occurrence of Alcaeorrhynchus grandis (Dallas) (Hemiptera: Pentatomidae) preying on defoliating caterpillars of oil palm in the state of Para, Brazil  

International Nuclear Information System (INIS)

The oil palm Elaeis guineensis is usually attacked by pests, particularly, defoliating caterpillars. Between 2004 and 2006 a stinkbug predator (Asopinae) was registered preying on caterpillars of Brassolis sophorae L., Opsiphanes invirae Hubner (Lepidoptera: Nymphalidae) and Sibine spp. (Lepidoptera: Limacodidae), reducing their populations in commercial oil palm plantations in the State of Para, Brazil. Specimens of the natural enemy were collected, mounted, and identified as Alcaeorrhynchus grandis (Dallas) (Hemiptera: Pentatomidae), corresponding to the first report of the occurrence of this stinkbug attacking defoliating caterpillars of oil palm in Brazil. (author)

2004-01-01

50

Electrochemical behavior of nickel in nitric acid and its corrosion inhibition using some thiosemicarbazone derivatives  

British Library Electronic Table of Contents (United Kingdom)

The adsorption and corrosion inhibition behavior of three selected thiosemicarbazone derivatives, namely 3-pyridinecarboxaldehyde thiosemicarbazone (META), isonicotinaldehyde thiosemicarbazone (PARA) and 2-pyridinecarboxaldehyde thiosemicarbazone (ORTHO) at the nickel surface were studied electrochemically by Tafel and impedance methods and computationally by carrying out Monte Carlo searches of configurational space on nickel/thiosemicarbazone derivative system. Electrochemical measurements showed that the inhibition efficiency of these compounds increased with increase in their concentration. The recorded inhibition efficiencies of the three tested thiosemicarbazone increase in the order: META>PARA>ORTHO. Polarization studies showed that these compounds act as mixed-type inhibitors for n...

2010-01-01

51

Determination of eigenvalues of real symmetric para-p diagonal matrices  

International Nuclear Information System (INIS)

A methods is presented for an accurate numerical determination of eigenvalues of real symmetric para-p diagonal matrices. The method takes advantage of the band structure to break up the matrix into p x p blocks and performing algebraic operations including inversions on these blocks only, no matter what the size of the matrix is. The eigenvalues are determined independently one at a time. Thus any error in the determination of one eigenvalue does not affect the other eigenvalues. The method is ideally suited for the Schroedinger eigenvalue problem of the anharmonic potentials. (author).

52

The behavior of thermally and optically stimulated luminescence of SrAl2O4:Eu2+,Dy3+ long persistent phosphor after blue light illumination  

International Nuclear Information System (INIS)

The behavior of afterglow (AG), thermoluminescence (TL), infrared stimulated luminescence (IRSL) and phototransferred TL (PTTL) under thermal and/or infrared (IR) stimulation in blue (470 nm) light illuminated at room temperature (RT) SrAl2O4:Eu2+, Dy3+ is presented. The TL glow curve consists of four peaks with maxima at about 340, 430, 560 and 680 K. The 340 and 440 K peaks are described well by second order kinetics with activation energies of 0.83 and 1.05 eV, respectively. The AG decay is fitted by the Becquerel's law with exponent 1.5 and correlates well with the thermal emptying of the traps responsible for the 340 K peak. The 340 and 430 K TL peak traps are destroyed under IR (830 nm) stimulation creating IRSL. IR stimulation after illumination with blue light and preliminary heating restore partially the 340 and 430 K TL peaks by phototransfer from deeper traps. The shape ...

2008-02-01

53

Tumour affinity of [sup 203]Pb-chloride: comparison with [sup 67]Ga-citrate and [sup 201]Tl-chloride  

Energy Technology Data Exchange (ETDEWEB)

[sup 203]Pb-chloride is a promising imaging agent for tumour scanning because of the large retention value for tumour tissue and the small value for normal organs, but the large value for the kidneys and bone is a shortcoming. The retention value of [sup 203]Pb in tumour tissue is larger than that of [sup 201]Tl and smaller than that of [sup 67]Ga. The tumour/inflammatory lesion retention ratio for [sup 203]Pb is very large in comparison with those for [sup 67]Ga and [sup 201]Tl. [sup 203]Pb accumulates to a large extent in viable tumour tissue, and less in necrotic tumour tissue and in inflammatory lesion. (author).

1994-01-01

54

Thermoluminescence of irradiated RbCl and RbCl:Sn crystals  

International Nuclear Information System (INIS)

The thermoluminescence (TL) and emission of coloured RbCl and RbCl:Sn crystals are studied in the temperature range 300 to 560 K. The glow peaks responsible for F centres and tin centres in different valence states are identified using optical bleaching studies. The glow peaks are analysed using total curve fitting method and the kinetic parameters are determined. In moderately #gamma#-irradiated tin-doped RbCl crystals, the TL emission bands observed at 4.0, 3.6, and 2.2 eV are attributed to Sn"0, Sn"+, and Sn"- centers, respectively. A comprehensive energy level diagram depicting the various TL processes in these undoped and tin-doped RbCl crystals is proposed. (author).

55

Purification of cyclotron-produced "2"0"3Pb for labeling Herceptin  

International Nuclear Information System (INIS)

A simple and rapid procedure was developed for the purification of cyclotron-produced "2"0"3Pb via the "2"0"3Tl(d,2n) "2"0"3Pb reaction. A Pb(II) selective ion-exchange resin, with commercial name Pb Resin from Eichrom Technologies, Inc., was used to purify "2"0"3Pb from the cyclotron-irradiated Tl target with excellent recovery of the enriched Tl target material. The purified "2"0"3Pb was used to radiolabel the monoclonal antibody Herceptin. The in vitro and in vivo properties of the "2"0"3Pb radioimmunoconjugate were evaluated.

2005-04-01

56

Comparative study of infrared-stimulated luminescent and thermoluminescent dating of archaeological artefacts  

Energy Technology Data Exchange (ETDEWEB)

In this study, thermoluminescence (TL) dating of archaeological artefacts from Geboltskirchen (Upper Austria) and Haselbach (Lower Austria) has been carried out. To receive a comparison with TL dating, all samples have been investigated additionally by means of infrared-stimulated luminescence (IRSL) analysis. The samples were prepared according to the common fine-grain technique. All important dating parameters such as potassium concentration, thorium/uranium ratio, moisture content, etc. were determined. A methodology for IRSL was developed, describing all steps of the procedure from sample preparation to measurement for any kind of ceramic artefacts. Dating results from TL and IRSL investigations of ancient pottery from Geboltskirchen and Haselbach will be discussed.

2008-02-15

57

The use of calcium silicate bricks for retrospective dosimetry  

International Nuclear Information System (INIS)

The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples ...

2004-02-01

58

Nuclear data sheets update for A = 203  

Energy Technology Data Exchange (ETDEWEB)

Experimental results of nuclear reaction and radiative decay for A = 203 nuclides are evaluated. Adopted properties for all the nine isobars, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr of mass 203 are presented. Nothing is yet known for [sup 203]Os. 96 refs.

1993-09-01

59

Nuclear data sheets update for A = 203  

International Nuclear Information System (INIS)

Experimental results of nuclear reaction and radiative decay for A = 203 nuclides are evaluated. Adopted properties for all the nine isobars, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr of mass 203 are presented. Nothing is yet known for "2"0"3Os. 96 refs.

60

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements ...

2005-10-23

61

Idaho Explosives Detection System  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Explosives Detection System was developed at the Idaho National Laboratory (INL) to respond to threats imposed by delivery trucks potentially carrying explosives into military bases. A full-scale prototype system has been built and is currently undergoing testing. The system consists of two racks, one on each side of a subject vehicle. Each rack includes a neutron generator and an array of NaI detectors. The two neutron generators are pulsed and synchronized. A laptop computer controls the entire system. The control software is easily operable by minimally trained staff. The system was developed to detect explosives in a medium size truck within a 5-min measurement time. System performance was successfully demonstrated with explosives at the INL in June 2004 and at Andrews Air Force Base in July 2004.

2005-12-01

62

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

63

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

64

Additional Surveys of Natural Hot Springs in Nakorn Si Thammarat Province  

International Nuclear Information System (INIS)

Having know of four more natural hot spring located in Amphur Phipun, Nakorn Si Thammarat Province, the present investigators went on July 27, 2005 to collect water samples from the four new hot springs in Ampur Phipun, Nakorn Si Thammarat Province. The methods of collection and the determination of radon gas and free-living amoeba were the same as those employed in previous studies. The results revealed radon concentrations higher than the drinking safety limits of 11 Bq/L in specimens from Baan Huaysai Kow (32.30 Bq/L) and Baan Hunob (31.18 Bq/L; both naegleria and acanthamoeba were present in the specimens of the above two sites, whereas only naegleria recovered from Baan Huaysai Kow (Nai Nukul place) and none from Baan Nong Bua.

2005-12-01

65

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial ...

2003-09-15

66

Decay behaviors of H{sub 2}{sup -} anions in solid parahydrogen. Effect of nuclear spins on chemical reactions  

Energy Technology Data Exchange (ETDEWEB)

Decay processes of H{sub 2}{sup -} anions in {gamma}-rays-irradiated solid parahydrogen were studied by using ESR spectrometer. The following interesting results were obtained. First, the initial amount of ortho-H{sub 2}{sup -} anions in the {gamma}-irradiated solid parahydrogen was three times as large as those of para-H{sub 2}{sup -} anions. Second, the amount of para-H{sub 2}{sup -} anions decreases faster than that of ortho-H{sub 2}{sup -} anions upon storage of the irradiated samples at 4.2 K. Third, the decay rate of H{sub 2}{sup -} anions is accelerated by the addition of D{sub 2} molecules. Forth, H{sub 2}{sup -} anions at 2.2 K decay faster than at 4.2 K. According to the parity conservation rule in a homonuclear diatomic molecule, the energy of ortho-H{sub 2}{sup -} anions at the ground state is lower than that of para-H{sub 2}{sup -} anions, whereas that of ortho-H{sub 2} molecules is higher than that of ...

1996-11-01

67

Thermoluminescence emission of X-irradiated Eu{sup 2+} doped KBr single crystals  

Energy Technology Data Exchange (ETDEWEB)

In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with {approx} 50 ppm of Eu{sup 2+} ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at {approx} 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu{sup 2+} impurity acts as an electron trap during the irradiation process ...

1996-12-31

68

Thermoluminescence emission of X-irradiated Eu"2"+ doped KBr single crystals  

International Nuclear Information System (INIS)

In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with #approx# 50 ppm of Eu"2"+ ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at #approx# 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu"2"+ impurity acts as an electron trap during the irradiation process and that ...

69

Using of Itaipu hydroelectric power plant-Brazil-electric power surplus for ammonia synthesis in nitrogen fertilizers production; Utilizacao da energia junto a Usina Hidreletrica de Itaipu para a sintese de amonia para fertilizantes nitrogenados  

Energy Technology Data Exchange (ETDEWEB)

Secondary energy can be described as a surplus of electrical energy in a hydropower because the lower demand of energy in some period of the day and the excess of water in the reservoir during the rainy periods. This study proposes the using of the excess of energy at Itaipu Bi nacional for electrolytically hydrogen production and ammonia for nitrogenous fertilizers. Ammonia is a raw material for nitrogenous fertilizers synthesis and produced using hydrogen and nitrogen from the atmosphere. This paper determines the minimal cost of hydrogen production and the capacity of hydrogen production, with this data and according the ammonia market for nitrogenous fertilizers in the Centre/South region was estimated the better capacity of ammonia production for one plant near Itaipu. The process of ammonia production using energy excess is the most environmental acceptable. (author)

2000-07-01

70

Quantization of the Lie algebra so(2n+1) and of the Lie superalgebra osp(1/2n) with preoscillator generators  

CERN Document Server

The Lie algebra so(2n+1) and the Lie superalgebra osp(1/2n) are quantized in terms of 3n generators, called preoscillator generators. Apart from n "Cartan" elements the preoscillator generators are deformed para-Fermi operators in the case of so(2n+1) and deformed para-Bose operators in the case of osp(1/2n). The corresponding deformed universal enveloping algebras U_q[so(2n+1)] and U_q[osp(1/2n)] are the same as those defined in terms of Chevalley operators. The name "preoscillator" is to indicate that in a certain representation these operators reduce to the known deformed Fermi and Bose operators.

1994-01-01

71

Alkylation of anisole with 1-hexene and 1-hexanol over zeolite H-beta  

British Library Electronic Table of Contents (United Kingdom)

An examination of the kinetics of the alkylation of anisole with 1-hexene and 1-hexanol to produce alkylates over zeolite H-beta is presented. Anisole alkylation is found to occur by a set of parallel reactions when hexene is used as the alkylating agent. When hexyl alcohol is the alkylating agent, the reaction follows a multi-step parallel-series mechanism to form monoalkylates and dihexylether. With 1-hexene, a group of isomeric alkylates, viz., ortho-2-hexyl anisole (2-OHA), ortho-3-hexyl anisole (3-OHA), para-2-hexyl anisole (2-PHA), and para-3-hexyl anisole (3-PHA) was obtained. With hexanol, the olefin (hexene) and dihexyl ether were obtained additionally. The influence of process parameters like temperature, catalyst quantity, and alkylating agent on reaction behavior is reported.

2011-01-01

72

Quantitative thallium-201 scintigraphy after dipyridamole infusion combined with low level exercise in healthy volunteers  

Energy Technology Data Exchange (ETDEWEB)

To establish test specific normal limits for quantitative analysis of uptake and washout of /sup 201/Tl after dipyridamole infusion combined with low level exercise, 20 healthy volunteers were studied with low likelihood of coronary artery disease (CAD) assessed by a stepwise probability analysis based on age, sex, symptoms, resting electrocardiogram, and exercise electrocardiography. Likelihood of CAD in these volunteers was calculated as less than or equal to 1%. After dipyridamole infusion combined with low level exercise, one volunteer complained of headache; no other side effects were observed. There were no chest pain complaints. Maximal hemodynamic changes were achieved during the 6th and 7th min of the test. No ST segment depression was recorded. Visual analysis of the /sup 201/Tl scintigrams was normal in all volunteers. Mean regional washout at 4 h was 44.37%+-2.11%. The regional washout in the 70/sup 0/ LAO view (46.65%+-1.10%) was ...

1989-05-01

73

A critical look at the kinetic models of thermoluminescence-II. Non-first order kinetics  

Energy Technology Data Exchange (ETDEWEB)

Non-first order (FO) kinetics models are of three types; second order (SO), general order (GO) and mixed order (MO). It is shown that all three of these have constraints in their energy level schemes and their applicable parameter values. In nature such restrictions are not expected to exist. The thermoluminescence (TL) glow peaks produced by these models shift their position and change their shape as the trap occupancies change. Such characteristics are very unlike those found in samples of real materials. In these models, in general, retrapping predominates over recombination. It is shown that the quasi-equilibrium (QE) assumption implied in the derivation of the TL equation of these models is quite valid, thus disproving earlier workers' conclusion that QE cannot be held under retrapping dominant conditions. However notwithstanding their validity, they suffer from the shortcomings as stated above and have certain lacunae. For ...

2005-01-07

74

USIMINAS experience on the fabrication of work cylinders for the tandem cold mill; Fabricacao de cilindros de trabalho para o laminador continuo a frio: a experiencia da USIMINAS  

Energy Technology Data Exchange (ETDEWEB)

A description is given of the principal steps involved in `USIMINAS` work roll manufacturing project for its tandem cold mill. The service performance of these rolls was found to be similar to that rolls supplied by traditional manufacturers. (author). 5 refs., 5 figs., 3 tabs.

1991-12-31

75

Steel microstructure engineering for large diameter tubes; Engenharia de microestrutura de acos para tubos de grande diametro  

Energy Technology Data Exchange (ETDEWEB)

High and ultra-high strength steels for pipelines are produced by properly handling the steel microstructure. The metallurgical principles involved in the microstructure control are presented, with emphasis on TMCP processing, that comprises conventional controlled rolling followed by accelerated cooling. (author)

2008-05-15

76

Some aspects for structure selection; Algunas consideraciones para seleccionar una estructura  

Energy Technology Data Exchange (ETDEWEB)

This paper shows some considerations about the cost of wood, steel and cement support pillars in rural power distribution systems. The life span, mechanical properties, cost estimation and general durability of each type of pillar was evaluated, aiming a better selection of the desired one. 6 figs., 8 tabs., 4 refs.

1986-12-31

77

Monitoring drinking water networks by data telemanagement; Telegestion de datos para control de redes de agua potable  

Energy Technology Data Exchange (ETDEWEB)

The WIT telemanagement system simply, reliably and efficient by makes available to us in real time processed, ordered and managed data. Such information has been used to optimise the performance of the drinking water distribution networks on a number of housing estates. This has led to major saving in consumption and on equipment maintenance, thereby improving customer service and obtaining a more rational use of piped water. (Author)

1997-04-01

78

La falta de financiacion publica hipoteca el futuro del acelerador de protones valenciano. La Universidad de Valencia tiene avanzado el diseno de este dispositivo de alta tecnologia  

CERN Multimedia

"La Universidad de Valencia tiene avanzado el diseno de un acelerador lineal de protones, cuya culminacion depende del compromiso del Consell en sufragar la plantilla que necesitaria el centro para estar operativo" (1 page).

2002-01-01

79

Folate fortification of rice by metabolic engineering  

British Library Electronic Table of Contents (United Kingdom)

Rice, the world's major staple crop, is a poor source of essential micronutrients, including folates (vitamin B9). We report folate biofortification of rice seeds achieved by overexpressing two Arabidopsis thaliana genes of the pterin and para-aminobenzoate branches of the folate biosynthetic pathway from a single locus. We obtained a maximal enhancement as high as 100 times above wild type, with 100 g of polished raw grains containing up to four times the adult daily folate requirement.

2007-01-01

80

Cyclopeptide alkaloids. Synthesis of the ring system and its ion affinity  

International Nuclear Information System (INIS)

Several examples of the 14-membered, para-bridged ring system of the cyclopeptide alkaloids have been synthesized via an active ester cyclization. The yield of monomeric cyclopeptide varied from 1 to 33% and was affected by the amino acid substitution pattern and amide conformation of the linear peptide precursors. Both the synthetic models and a naturally occurring cyclopeptide alkaloid, ceanothine B, bind monovalent (Li"+) and divalent (Ca"2"+, Mg"2"+) cations. 4 figures, 1 table.

81

Air pollution abatement 1981. Luftreinhaltung '81. Entwicklung - Stand - Tendenzen. Materialien zum Zweiten Immissionsschutzbericht der Bundesregierung an den Deutschen Bundestag nach Para. 61 Bundes-Immissionsschutzgesetz  

Energy Technology Data Exchange (ETDEWEB)

The development of emmissions, the measures planned and carried out and the present state of research in the Federal Republic of Germany into air pollution effects and abatement technology is reported. Possible starting points and solutions for air pollution abatement measures are explored within the legal framework.

1981-01-01

82

Softwood forest thinning as a biomass source for ethanol production: A feasibility study for California  

Energy Technology Data Exchange (ETDEWEB)

A plan has been put forth to strategically thin northern California forests to reduce fire danger and improve forest health. The resulting biomass residue, instead of being open burned, can be converted into ethanol that can be used as a fuel oxygenate or an octane enhancer. Economic potential for a biomass-to-ethanol facility using this softwood biomass was evaluated for two cases: Stand-alone and co-located. The co-located case refers to a specific site with an existing biomass power facility owned by Wheelabrator Environmental Systems Inc. near Martell, California. A two-stage dilute acid hydrolysis process is used for the production of ethanol from softwoods, and the residual lignin is used to generate steam and electricity. For a plant processing 800 dry tonnes per day of feedstock, the co-located case is an economically attractive concept. Total estimated capital investment is approximately $ 70 million for the co-located case. The resulting internal rate of return is about 24% ...

2000-07-01

83

Utilization of Tc-99m-TBI as a myocardial perfusion agent in exercise studies: Comparison with Tl-201 thallous chloride and examination of its biodistribution in humans  

Energy Technology Data Exchange (ETDEWEB)

Twenty-four patients were studied with both /sup 201/Tl-thallus chloride and /sup 99m/Tc-TBI scintigraphy following exercise. Comparison of the two agents in detecting segmental myocardial ischemia and scar was made in 18 patients with evidence of coronary artery disease on /sup 201/Tl-thallous chloride scintigraphy. Agreement between the two studies was observed in 77% (125 of 162) of left ventricular segments, suggesting that /sup 99m/Tc-TBI can be used as a myocardial perfusion agent. Limitations were related to early high background activity from lungs and liver. The high lung activity and early myocardial redistribution within the 1st hour contributed to the failure of /sup 99m/Tc-TBI to detect 16 segmental defects seen in the immediate post-exercise thallous chloride scan. Persistently high liver activity additionally affected accurate interpretation in the left ventricular segments close to the diaphragm. Improvement in the accuracy of ...

1986-10-01

84

Positron annihilation in high-T/sub c/ superconductors  

International Nuclear Information System (INIS)

We report ab initio calculations of positron wave functions in the high-T/sub c/ superconductors YBa_2Cu_3O_7, Bi_2Sr_2CaCu_2O_8, and Tl_2Ba_2CaCu_2O_8 using the general potential linearized augmented plane-wave method. The calculated positron wave functions are fairly insensitive to whether or not electron-positron correlation is included in the calculation for YBa_2Cu_3O_7 and Tl_2Ba_2CaCu_2O_8, but the calculated positron density is quite sensitive to correlation in Bi_2Sr_2CaCu_2O_8. While the positron wave function samples primarily the chain region in YBa_2Cu_3O_7, the results indicate that positrons should be good probes of the Cu-O layer-derived electronic states near the Fermi energy in Tl_2Ba_2CaCu_2O_8 since a large overlap with these states is predicted.

85

Optimization of isotope production by cross section determination  

International Nuclear Information System (INIS)

In order to optimize the production of "2"0"1Tl and "6"7Ga using the (p, xn) reactions on enriched "2"0"3Tl and "6"8Zn targets we established a new set of cross section curves for the most relevant reactions. Target stacks made of up to 15 thin (50 #mu#m) natural Tl or Zn foils interleaved with brass degradation foils were irradiated with incident proton energies from 42 to 10 MeV in overlapping experiments. Yields for "2"0"0","2"0"1","2"0"2"m","2"0"3","2"0"4"mPB and "6"6","6"7","6"8Ga were computed from measured #gamma# emission rates. Where possible, cross section curves for the nuclear reactions involved were computed. Thick target yields and contamination ratios for enriched targets were derived and show good agreement with results from actual production runs. (orig.).

86

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS  

International Nuclear Information System (INIS)

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an ...

2010-07-11

87

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of ...

1998-06-01

88

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...

89

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

90

Separation of /sup 203/Pb by ion-exchange chromatography on Chelex 100 after production of /sup 203/Pb by the Pb(p,xn)/sup 203/Bi/sup EC. beta. +/ -> /sup 203/Pb nuclear reaction  

Energy Technology Data Exchange (ETDEWEB)

Bismuth radioisotopes, produced by 50-MeV proton bombardment of a lead target in a cyclotron, are separated from the lead target material by ion-exchange chromatography on a column containing 5.0 ml of Chelex 100. After a decay period of 24 hr, the /sup 203/Pb formed in situ is eluted from the column and then separated from /sup 200/Tl and /sup 201/Tl on a second ion-exchange column containing 0.5 ml of Chelex 100. Separations are sharp and carrier-free /sup 203/Pb is obtained.

1989-04-01

91

Nuclear magnetic resonance study of La_3X compounds and related phases  

International Nuclear Information System (INIS)

Normal state nuclear magnetic resonance studies of the La_3In, La_3Tl compounds have been made in order to investigate the origin of the large temperature-dependent magnetic susceptibility. It is possible to analyse the different contributions to the susceptibility using Knight-shift and relaxation time T_1 measurements of In"1"1"5 and Tl"2"0"5 nuclei. The exchange enhancement of the spin-susceptibility chisub(pd) is of the same order as that found in A-15 compounds and the strong temperature-dependence of chi(T) is attributed to the presence of a peak in the electronic density of states near the Fermi level. The variation of the Knight-shift in the ternary alloys La_3Xsub(1-y)Xsub(y)sup(') is analogous to that observed in the corresponding La_3X phases, on the other hand the Knight-shift in the carbides La_3XC is temperature independent. (author).

92

Cyclotron produced lead-203  

International Nuclear Information System (INIS)

The radioactive isotopes of lead are reviewed with respect to their choice for in vitro tracer studies. The #gamma#-photon energy and absence of particle emission in the decay of "2"0"3Pb makes it particularly suitable for these applications. Reaction yields of "2"0"3Pb using "2"0"3Tl targets and proton, deuteron, "3He and "4He beams are listed. Using the preferred reaction "2"0"3Tl (d, 2n)"2"0"3Pb with a 15 MeV deuteron beam, yields of about 75 #mu#Ci #mu#Ahr"-"1, after chemical separation, are reported. Details of target design and chemical separation are given. (U.K.).

93

{open_quotes}Pre-residue{close_quotes} light charged particles from {sup 28}Si+{sup 165}Ho and {sup 16}O+{sup 197}Au, {sup 208}Pb fusion  

Energy Technology Data Exchange (ETDEWEB)

Proton and alpha particle spectral shapes and multiplicities have been measured in coincidence with evaporation residues from {sup 28}Si+{sup 165}Ho and {sup 16}O + {sup 197}Au, {sup 208}Pb fusion reactions. Our experiments used 145 to 220 MeV {sup 28}Si and 115 and 140 MeV {sup 16}O beams produced with the Stony Brook LINAC. ER`s were separated using an electrostatic deflector and detected with large area surface barrier detectors. Light charged particles were detected at forward and backward angles with fourteen single NaI detectors. In the context of the statistical model, charged particle spectra yield information about emission barriers and compound nucleus equilibrium level densities. These are significant ingredients in calculations determining fission timescales from other observables such as pre-scission neutron multiplicities or fusion-evaporation excitation functions. Results will also be compared to analyses of pre-scission charged particles from ...

1993-10-01

94

The E = mc{sup 2} exhibition  

Energy Technology Data Exchange (ETDEWEB)

The goal of this DOE-supported exhibition is to demystify Einstein`s formula E = mc{sup 2} by illustrating the interchangeability of matter (m) and energy (E), c{sup 2} being the exchange rate. The exhibition has two major parts, {open_quotes}matter into energy{close_quotes} and {open_quotes}energy into matter{close_quotes}, plus a video to connect them. {open_quotes}Matter into energy{close_quotes} has now been completed and has been placed on the museum floor. Positrons from a {sup 22}Na source are annihilated to produce gamma rays that are caught in NaI detectors. The viewer can alter the alignment of the detectors and observe the consequences for the rates of single and coincident counts. The viewer can also observe the effects of placing absorbers in front of the counters. Prototype explanatory graphics were placed around the exhibit and those will probably be changed after we have some experience with their effectiveness. The connecting video is in the ...

1995-08-01

95

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can avoid these demerits. This analysis method was applied to the ...

1996-10-01

96

Numerical analysis of natural convection in a square cavity at high Rayleigh numbers using the GSMAC finite-element method. GSMAC yugen yosoho ni yoru ko Rayleigh su seihokei cavity nai shizen tairyu no hi teijo kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Stable and accurate numerical analytical method even at high Rayleigh numbers is desired, and in addition flexibility and economical efficiency are very important for numerical analysis. Unsteady flows of natural convention in a square cavity are investigated using the GSMAC (generalized and simplified marker and cell) finite-element method at high Rayleigh numbers from 10 {sup 6} to 10 {sup 8}. Validities of the multi-pass algorithm and BTD (balancing tensor diffusivity), which are highly accurate solutions for finite-element method, are investigated by introducing them to the GSMAC finite-element method. As the result, it was found that the multi-pass algorithm has little effect for the GSMAC finite-element method. The steady solutions at the Rayleigh numbers of 10 {sup 5} and 10 {sup 7} agreed well with the bench mark solutions and numerical solutions. Complex transient phenomena at Rayleigh numbers higher than 10 {sup 7} are successfully observed. 12 refs., 11 figs., 4 tabs.

1990-10-25

97

Effect of water content on the activity of lipase-hydrolysis of olive oil in reverse micelles. Gyakuso micelle nai ni okeru lipase no olive oil kasui bunkai hanno no gansuiritsu izonsei  

Energy Technology Data Exchange (ETDEWEB)

Hydrolysis of olive oil by Chromobacterium viscosum lipase was studied in a reverse micellar system of a anionic surfactant Aerosol OT (AOT) and isooctane. Different methods of solubilization of the micellar system afford specific dependence of enzymatic activity of the lipase on the water content in the micelles. In an injection method, water content is controlled by the amount of injected water, which determines the micelle size and hydrophobicity of the micelle without salt addition and changes reversibly the conformation of lipase corresponding to the change of lipase activity. The activity reaches the maximum at a water content (water/AOT)of 7. In a phase transfer method, water content is determined by salt concentration in the aqueous phase in contact with micelles and the water content corresponding to the maximum activity is 12 to 13, below which the activity decrese drastically. Addition of taurodeoxycholic acid to the AOT micelles suppresses the reversible conformational ...

1992-01-10

98

A Radiation Laboratory Curriculum Development at Western Kentucky University  

Science.gov (United States)

We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and Radiation Biophysics). Our goal is to develop a set of ...

2009-03-10

99

Heat transfer equipment performance diagnosis of auxiliary systems in electric power stations; Diagnostico de comportamiento de equipo de transferencia de calor de sistemas auxiliares de centrales termoelectricas  

Energy Technology Data Exchange (ETDEWEB)

In this article the methodology followed to diagnose the performance of the equipment where heat is transferred from the feed water, condensate and circulation water systems in fossil power plants (FPP). The data collection is made with the unit in normal operation, using local instrumentation without taking the equipment out of service for its installation. The equipment diagnosis is made through the analysis of the collected data in actual operation and the design data; for this purpose a thermal balance of the interested systems is performed to obtain all the conditions an operation data. Later on the performance indicative parameters (PIP) of actual operation and design are calculated and compared one against the other. Such a comparison reveals the performance deterioration and the possible equipment faults. The data obtained and the supplementary information are stored in a data base whose objective is that Comision Federal de Electricidad has on hand a prompt access to them in ...

1990-12-31

100

lla4892q.305  

Science.gov (United States)

PeDEL GRcXPmDtlSEZ`H==>T32\\ZtrPOP6tM UKwNEH5|J?:O TONRHwIN O1?)J`MiO\\ ?CQBYIL robb_M RSM7A8: qL6;90f44:7\\I07QO AE/U U_PbqIBYc6mTL?:2NDerX=Z =P<;K aRITGUN ...

101

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

102

Solution of Bohr's collective Hamiltonian for transitional odd-mass nuclei  

International Nuclear Information System (INIS)

A numerically feasible method, based on the use of deformed phonons, is developed for the diagonalization of the collective quadrupole Hamiltonian for a system with an odd particle coupled to an anharmonic even core. Examples: the transition from prolate to oblate via #gamma#-unstable shapes and furthermore the hsub(9/2) spectra of the nuclei "1"8"7Ir and "1"9"7Tl. (Auth.).

103

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

104

Optically stimulated luminescence (OSL) study of synthetic stishovite  

International Nuclear Information System (INIS)

Optically stimulated luminescence (OSL) of synthetic stishovite was investigated for a future dating technique of meteor impact craters. Luminescence around 330 nm was measured on the #gamma#-ray irradiated stishovite under two stimulating light sources of infrared laser (830 nm) and blue light emitting diode set (470 nm). Thermoluminescence (TL) studies before and after the OSL measurements showed the intensities around 100-200 deg. C and 220-350 deg. C to increase and those around 350-450 deg. C to decrease. This indicates that a part of deep-trapped charges excited during the OSL measurements were retrapped by shallower traps. The infrared stimulated luminescence (IRSL) after the TL measurement up to 450 deg. C could not be detected, while the blue light stimulated luminescence (BLSL) after TL had about one-tenth of the intensity before TL. This indicates that a part of the charges in shallower traps ...

2000-12-15

105

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

106

Large scale rooftop photovoltaics grid connected system at Charoenphol-Rama I green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a technical feasibility study project for the large scale rooftop photovoltaics (PV) grid connected system at Charoenphol-Rama I green building super store of TESCO LOTUS (TL) in Thailand. The objective of this project is (i) to study the technical feasibility of installation 350 kWp PV systems on the top of the roof in this site (ii) and to determine the energy produce from this system. The technical factors are examined using a computerized PVS 2000 simulation and assessment tool. This super store building located in Bangkok, with latitude 14 N, longitude 100 E and the building direction is 16 from North direction. The building roof area is 14,000 m2; with 3 degree face East and 3 degree face West pitch. Average daily solar energy in this area is approximately 5.0 kWh. The study team for this project consists of educational institution as School of Renewable Energy Technology (SERT) and private institution as Panya Consultants (PC). ...

2004-07-01

107

Anomalous solvent extraction behavior of astatine  

International Nuclear Information System (INIS)

We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).

108

Alpha particle induced TL supralinearity in TLD-100: dependence on vector properties of the radiation field  

Energy Technology Data Exchange (ETDEWEB)

The linear/supralinear behaviour of the TL dose response in LiF:Mg,Ti (TLD-100) and its dependence on ionisation density is a fairly unique phenomenon which cannot be explained by conventional atomic 'conduction band/valence band' kinetic models. The Track Interaction Model (TIM) provides the microscopic framework which, when coupled with other appropriate physical mechanisms (spatial localisation of traps and recombination centres, competing centres, variations in the capture cross sections with temperature, etc.) can be used to describe all the dominant features of the TL supralinearity of LiF:Mg,Ti and similar TL systems. The unique feature of the TIM applied to alpha particles is that it is an integral approach with only one free parameter, the average charge carrier migration distance in the luminescence recombination stage. Although the TIM provides a comprehensive description of the mechanisms ...

1993-01-01

109

Study for application of multi fuel technology in the Brazilian automobilistic market; Estudo para aplicacao da tecnologia multi combustivel no mercado automobilistico brasileiro  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is a study for the application of a new technology that will be used in the engine management system in the vehicle; where the final consumer can opt for the inquiry performance or seeking an economy for the fuel consumption depending on its daily use and of the prices offered in the gas stations. Flexible Fuel is a technology in development for the automobile market that mixes the use of two fuels (gasoline and ethanol) and their mixtures in the internal combustion engine. (author)

2006-07-01

110

SIRIO: Computer system for the follow up and the optimum planning of short time exploitation of a hydroelectric system; SIRIO: sistema informatico para el seguimiento y la programacion optima de la explotacion a corto plazo de un sistema hidroelectrico  

Energy Technology Data Exchange (ETDEWEB)

Sirio is a computerized application to manage the hydroelectric system in a short time. This management is implemented as a real time tool in the Control Department. SIRIO has many modules, independent and integrated to operate and perform the data acquisition, optimization, planning simulation and planning optimization. This article presents the SIRIO System and its applications to the Iberdrola system in Tajo river.

1994-12-31

111

Project scheduling with resources constraints: application in the equipment production for the oil industry; Scheduling de projetos com restricao de recursos: aplicacao na producao de equipamentos para a industria de petroleo  

Energy Technology Data Exchange (ETDEWEB)

One of the essential steps in the main scope Project Management is the Time Management made by the planning and control of the project schedule. In this work is presented the resource constrained scheduling problem beyond its mathematical formulation and a review of papers about this issue. In sequence is presented a practical example of this model considering a simplified model of an engineering project schedule of oil production equipment. The results obtained with the model application are shown and the conclusions about the work with resource constrained scheduling problems. (author)

2008-07-01

112

Methodology for fabrication of hydraulics mini turbines with composite materials; Metodologia para a fabricacao de mini turbinas hidraulicas com materiais compostos  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the description of methodological procedure specially developed for manufacturing mini turbines. This procedure is used in the design of a Francis type mini turbine with 12.5 kW. The housing volute and the suction tube of this equipment are manufactured with using composed material based on glass fiber and its distributor system is manufactured with stainless steel and brass. At the end it is presented an estimate cost of design / manufacturing of such equipment and a comparison with other equipment in the market.

2009-07-01

113

Method to generate the first design of the reload pattern to be used with the Presto-B code in the simulation of the CNLV U-1 reactor; Metodo para generar el primer diseno del patron de recarga a ser utilizado con el codigo Presto-B, en la simulacion del reactor de la CNLV U-1  

Energy Technology Data Exchange (ETDEWEB)

This guide is applied for the reload pattern's formation for mirror symmetry of a core room and in accordance with the Control Cell core technique (of the english Control Cell Core - CCC) for the PRESTO-B code. (Author)

1992-08-15

114

Kevlar, the 'universal fiber'. Properties and applications in industry, sports and recreation. Kevlar - die 'Alleskoenner-Faser'. Eigenschaften und Anwendung in Industrie, Sport und Freizeit  

Energy Technology Data Exchange (ETDEWEB)

This article gives a survey of the history, properties and applications of 'Kevlar' aramide fibers. For example, the 'Kevlar' para-aramide fiber is used in compound materials in ship-, aircraft- and vehicle construction. 'Kevlar' is used as a replacement for asbestos, for example in brakes, clutches and seals or as rubber reinforcement (tyres, conveyor belts, hoses). The aramide fibers also offer manufacturers of ropes, hawsers and cables a near ideal range of properties. (MM).

1988-12-01

115

Development of a synchronous key to controlled energization of three-phase transformers; Desenvolvimento de uma chave sincrona para energizacao controlada de transformadores trifasicos  

Energy Technology Data Exchange (ETDEWEB)

This work describes the development of a synchronous key based on micro controller to the switching of three-phase power transformers, which makes possible the achievement of tests to register the inrush current, and the previous establishment of the instantaneous values of the voltage firstly applied to different phases of the energy process. This key is a value tool to the development electric power system projects and to the teaching and researching activities at the laboratory related to transitory phenomena and electric system protection.

2009-07-01

116

Supramolecular selectivity of [60]-fullerene among equivalently photoactive porphyrins  

International Nuclear Information System (INIS)

The photophysical investigation of different para-substituted tetraphenylporphyrins (TP), viz., meso-tetra(4'-hydroxyphenyl)-21H-23H-porphyrin(1),meso-tetrakis (4'-hex-5-enyloxyphenyl)-21H-23H-porphyrin(2), meso-tetrakis(4'-oct-7-enyloxyphenyl)-21H-23H-porphyrin(3) and meso-tetrakis(4'-undecyloxyphenyl)-21H-23H-porphyrin (4) revealed that except for quantum yield (#phi#) the para-substitution has little effect on any other photophysical properties like lifetime, excitation, emission wavelength, etc. The host-guest type interactions of these tetraarylporphyrins (TP 1-4), with [60]-fullerene (F) have been studied with "1H NMR and fluorescence spectrometric techniques in carbon tetrachloride medium. Fluorescence studies revealed that the Q band of the TPs was sufficiently quenched upon addition of F. All the fullerene/porphyrin systems were found to produce stable complexes with 1:1 stoichiometry. Binding constants (K) of all the ...

2010-10-01

117

Qualitative aspects in the projects that are developed in the Instituto de Investigaciones Electricas; Aspectos cualitativos en los proyectos que se desarrollan en el Instituto de Investigaciones Electricas  

Energy Technology Data Exchange (ETDEWEB)

The globalization of markets has generated more options of purchase of all type of goods and services, these options have generated opportunities and threats for all the companies and have looked for the satisfaction of the client as a strategy to remain or incursion into the global market. The Instituto de Investigaciones Electricas (IIE) is not the exception and therefore it looks for the identification of the qualitative aspects and to systematize its application in the projects that executes by means of the implantation of a system of quality assurance based on the series of ISO 9000 Standards. Some examples are described to identify the qualitative aspects of the projects that are developed in the Institute. [Spanish] La globalizacion de los mercados ha generado mas opciones de compra de todo tipo de bienes y servicios, dichas opciones han generado oportunidades y amenazas para todas las empresas y se ha buscado satisfacer al cliente como estrategia ...

1999-07-01

118

Yield and excitation function measurements of some nuclear reactions on natural thallium induced by protons leading to the production of medical radioisotopes {sup 201}Tl and {sup 203}Pb  

Energy Technology Data Exchange (ETDEWEB)

Excitation functions for {sup 201}Pb, {sup 202m}Pb, {sup 203}Pb and {sup 204m}Pb radionuclides which are formed via proton induced reactions with natural thallium target have been measured from their respective threshold (E{sub thr}) to 27.5 MeV using activation technique. Natural copper foils were used to monitor the cyclotron beam. The integral yields (MBq/{mu}A h) of the produced radionuclides were calculated from the measured excitation functions. The optimum proton energy range for the production of {sup 203}Pb with low amount of impurities is (16-10 MeV) after 5 h of EOB. The experimental cross-sections for {sup nat}Tl(p,xn) reactions were compared with the cross-sections recommended by the IAEA and with earlier published data when it was possible. (orig.)

2007-07-01

119

Usefulness of myocardial imaging by [sup 123]I-MIBG in assessment of diabetic neuropathy  

Energy Technology Data Exchange (ETDEWEB)

In diabetic patients with autonomic neuropathy, it is suggested that there is a reduced uptake of [sup 123]I-metaiodobenzylguanidine (MIBG) in the heart. We compared the difference of myocardial [sup 123]I-MIBG accumulation between 4 diabetic patients with triopathy and 6 patients without it. In all 10 patients, coronary angiography and [sup 201]Tl imaging (rest and 4 hours later) were performed. [sup 123]I-MIBG (111 MBq) was administered intravenously and its imaging was recorded on 15 minutes and 4 hours after injection. In all 4 cases with triopathy, [sup 123]I-MIBG imaging showed defect in apical and inferior region. In 2 out of 6 cases without triopathy, rapid clearance was noticed in apical and inferior region. There was no significant stenosis in right coronary artery and no defect in initial and delayed [sup 201]Tl images in all cases. We concluded that diabetic autonomic neuropathy in the heart was prominent in apical and inferior ...

1993-10-01

120

The response of some TL albedo neutron dosimeters  

International Nuclear Information System (INIS)

As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its response varies roughly as the cosine of the angle of incidence but is more complex at higher energies. (author).

121

Preliminary study of the application of natural olivine in Cenozoic dating  

Energy Technology Data Exchange (ETDEWEB)

The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL signal component ...

2006-08-15

122

NMR in highly correlated superconductors  

International Nuclear Information System (INIS)

Results of our systematic NMR study in high T_c cuprates are reviewed. The antiferromagnetic spin fluctuations (AFSF) decrease in the order of La_1_._8_5Sr_0_._1_5CuO_4. YBa_2Cu_3O_7 and Tl_2Ba_2CuO_6_+_y. 1/T_1 of "6"3Cu in the CuO_2 plane in the normal state follows essentially a Curie-Weiss law at high temperature and T_1T = const. law at low temperature. The temperature dependence of 1/T_1 and the Knight shift together with their impurity effect in the superconducting state strongly suggest d-wave pairing implying the AFSF to be responsible for the occurrence of superconductivity. From the NQR frequency measurement the density of Cu 3d and O 2p holes decreases and increases, respectively, in the order of La, Y and Tl compounds, which is consistent with the change of AFSF. The relation between T_c and #nu#_Q, and their pressure dependence suggest that there exists and optimum value of the ratio of Cu 3d and O 2p hole density to give a ...

1992-08-01

123

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.

2008-05-22

124

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

125

The production of carrier-free lead-203  

International Nuclear Information System (INIS)

The chemical separation of carrier-free "2"0"3Pb following deuterium bombardment of a "2"0"3Tl target is described. Coprecipitation from strontium sulphate was used to separate the "2"0"3Pb from a solution of the thallium target in sulphuric acid. The SrSO_4 precipitate was filtered, washed and dissolved in hydrochloric acid, from which "2"0"3Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given. (U.K.).

126

The 8{pi}LP Project: A 4{pi} light charged particle detection array at LNL  

Energy Technology Data Exchange (ETDEWEB)

A 4{pi} detection system sensitive to light charged particles is being developed at the Laboratori Nazionali di Legnaro (LNL) for the study of reaction mechanisms at energies up to 20 AMeV. The array consists of 262 {Delta}E-E telescopes covering 90% of 4{pi}. Each telescope is made of a 300 {mu}m passivated silicon detector and a 15 mm (or 5 mm) CsI(Tl) crystal read by a photodiode. The system will be operational in the Spring of 1997 and the first experiments will run in the second half of 1997.

1996-12-31

127

Shielded and unshielded geometries in the search for orphan sources  

Energy Technology Data Exchange (ETDEWEB)

A car-borne NaI(Tl) spectrometric system was used together with a {sup 137}Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-15

128

Shielded and unshielded geometries in the search for orphan sources  

International Nuclear Information System (INIS)

A car-borne NaI(Tl) spectrometric system was used together with a "1"3"7Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-01

129

Production of carrier-free lead-203  

Energy Technology Data Exchange (ETDEWEB)

The chemical separation of carrier-free /sup 203/Pb following deuterium bombardment of a /sup 203/Tl target is described. Coprecipitation from strontium sulphate was used to separate the /sup 203/Pb from a solution of the thallium target in sulphuric acid. The SrSO/sub 4/ precipitate was filtered, washed and dissolved in hydrochloric acid, from which /sup 203/Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given.

1982-07-01

130

Primary standardization of {sup 242} Am radioactive sources  

Energy Technology Data Exchange (ETDEWEB)

The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)

2001-07-01

131

Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92  

International Nuclear Information System (INIS)

The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.

1989-01-01

132

Nondestructive analysis for "2"3"2U and decay progeny in animal tissues  

International Nuclear Information System (INIS)

Direct determination of "2"3"2U and its decay products in animal tissues appears to be feasible using an intrinsic Ge(Li) diode detector (for energies of 5-100 keV) and a NaI(Tl) anticoincidence-shielded Ge(Li) diode for higher-energy gamma photons. The detection sensitivity for "2"3"2U and "2"2"8Th is 0.03 and 0.01 nCi, respectively, using a 300-min counting time.

1977-05-01

133

Modification of NPL-CRC secondary standards radionuclide calibrator holder to suit for IPEN vials  

International Nuclear Information System (INIS)

The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)

2000-10-05

134

A new method for the analysis of infrared stimulated luminescence data from potassium feldspars  

International Nuclear Information System (INIS)

A new method is described for the analysis of high precision pulse annealing data obtained using IRSL measurements on potassium feldspars using a Risoe reader. Presenting the data as the percentage of the signal lost per annealing phase permits more detailed comparisons to be made between samples. In addition, it is possible to directly compare the temperatures at which the TL and IRSL signals are released, thus giving information about the relationship between them. This method of analysis is applied to pulse annealing data for natural, irradiated, preheated and IR bleached aliquots. (author).

1993-07-01

135

[sup 123]I-MIBG myocardial scintigraphy in diabetic patients. Relationship with [sup 201]Tl uptake and cardiac autonomic function  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to investigate the influence of diabetic myocardial damage (suspected myocardial damage; SMD) diagnosed by [sup 201]Tl-SPECT and diabetic cardiac autonomic neuropathy (AN) on myocardial MIBG uptake in patients with NIDDM. Eighty-seven diabetic patients divided into four subgroups: 23 with SMD (+) AN (+); 19 with SMD (+) AN (-); 27 with SMD (-) AN (+); 18 with SMD (-) AN (-), and 10 controls were studied. Both planar and SPECT images were taken at 30 minutes (early) and 3 hours (delayed) after [sup 123]I-MIBG injection. The heart to mediastinum uptake ratio (H/M) and washout ratio of [sup 123]I-MIBG (WR) were obtained from both planar images. Similarly, the difference between the [sup 201]Tl image and the [sup 123]I-MIBG image in the total uptake score (TUS) was taken as the difference in the total uptake score ([Delta]TUS) representing cardiac sympathetic denervation without SMD. On both early and delayed planar ...

1998-12-01

136

Syntheses and crystal structures of the compounds In_3_._7Mo_1_5S_1_9, In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9 and ScTl_2Mo_1_5S_1_9 containing Mo_6 and Mo_9 clusters  

International Nuclear Information System (INIS)

The new compounds In_3_._7Mo_1_5S_1_9, In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9, and ScTl_2Mo_1_5S_1_9 have been synthesized by solid-state reaction in sealed molybdenum crucible at about 1250 deg. C. Their crystal structures were solved and refined from X-ray single-crystal data in the hexagonal space group P63/m. Their Mo-S framework consists of an equal mixture of Mo_6S_8S_6 and Mo_9S_1_1S_6 cluster units interconnected through Mo-S bonds. In In_3_._7Mo_1_5S_1_9, the In atoms occupy crystallographically different positions depending on their formal oxidation states of +1 or +3. This was confirmed by replacing partially or totally the monovalent indium by another monovalent cation such as the rubidium, cesium or thallium and the trivalent indium by the scandium to get the new In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9, and ScTl_2Mo_1_5S_1_9 compounds, respectively.

2004-11-30

137

Respiratory impairment due to asbestos exposure in brake-lining workers  

International Nuclear Information System (INIS)

There is extensive evidence that exposure to asbestos causes pulmonary parenchyma fibrosis, pleural disease, and malignant neoplasm in asbestos-exposed workers. However, few data concerning brake-lining workers are available in the literature. In this study, we aimed to assess the long-term effects of chrysotile asbestos exposure on lung function and the risk of asbestos-related diseases in brake-lining workers. Seventy-four asbestos-exposed workers who processed brake-lining products and 12 unexposed office workers were offered pulmonary function tests (spirometry and transfer actor) in 1992 and 1999. In 1999, the mean duration of asbestos exposure was 0.00#+-#4.07 and 11.02#+-#4.81 years (7-31 years) in non smoking and smoking asbestos workers, respectively. Transfer factor (T_L, CO) and transfer coefficient (K_C_O) decline were significant in the 7-year follow-up in both smoking and non smoking asbestos workers. However, lung function indices of he control ...

2003-03-01

138

Intrinsic Dosimetry Of Glass Containers Used To Transport Nuclear Materials: Potential Implications to the Field of Nuclear Forensics  

International Nuclear Information System (INIS)

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of ...

139

35 years of Thermoluminescence Dosimetry (TLD) in personnel and environmental monitoring in India - a tribute to Dr. K G Vohra  

International Nuclear Information System (INIS)

Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully ...

140

Validation of a new software version for monitoring of the core of the Unit 2 of the Laguna Verde power plant with ARTS; Validacion de una nueva version del software para monitoreo del nucleo de la Unidad 2 de la Central Laguna Verde con ARTS  

Energy Technology Data Exchange (ETDEWEB)

In this work it is intended a methodology to validate a new version of the software used for monitoring the reactor core, which requires of the evaluation of the thermal limits settled down in the Operation Technical Specifications, for the Unit 2 of Laguna Verde with ARTS (improvements to the APRMs, Rod Block Monitor and Technical specifications). According to the proposed methodology, those are shown differences found in the thermal limits determined with the new versions and previous of the core monitoring software. Author)

2005-07-01

141

Use of sodium aluminate in waste water treatment plants: wishes of saving money and innovating; Uso del aluminato sodico en las EDAR: una propuesta para innovar y economizar costes de explotacion  

Energy Technology Data Exchange (ETDEWEB)

Most waste water treatment plants have processes to remove nutrients in order to avoid eutrophication in water receiving bodies. Regarding phosphorus removal. the most common option is chemical precipitation with ferric or aluminical precipitation with ferric or aluminium salts. We show here the successful experience carried out by the WWTP of Blanes and the company Safloc. A method ato remove phosphorus from waste water was developed by adding sodium aluminate. The use of this compound has turned out to be a sustainable way for this purpose in terms of costs, reliability and minimization of sludge production. (Author)

2006-07-01

142

Sensors to detect CO based in SnO. Sensores para detectar CO basados en SnO  

Energy Technology Data Exchange (ETDEWEB)

The development of solid state chemical sensors, and more specifically of gas sensors, is carried out with great strength in the present time since the environmental pollution and the security in work and domestic ambient are problems of great interest and social impact. The main fields of application, are: automobile, domestic sensors, control of industrial process, bio medicine, environment. These chemical sensors are experimenting a great advance because of the advantages they offer, as low cost, simple operation, possibility of measure continuous and ''In situ'' and small size, in contrast with analytical techniques that need complex instrumentation and large size equipments. In the present work, a sensor for CO detecting concentrations as low as 50 p.p.m., is studied showing great interest since this gas is highly toxic even to such a low concentration. (Author)

1993-01-01

143

Project of the new measurement system for energy invoicing - Itaipu Hydroelectric Central; Proyecto del nuevo sistema de medicion de energia para facturacion de la Central Hidroelectrica de Itaipu  

Energy Technology Data Exchange (ETDEWEB)

Itaipu Binacional has taken a decision of executing a technological updating for the energy measurement system through the substitution of the current system by other one equipped with digital devices. The main reasons for that were the following: a) The equipment in operation were of an outdated generation b) The accuracy class of the existing equipment was of 0.5%, but the tendency for invoicing measurements was to install meters with accuracy class of 0.2% in the enterprises c) The requirements of ONS/MAE, in Brazil, which establishes the minimum requisites to be attended by invoicing measurement systems.

2001-07-01

144

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

145

Optimized sizing model for renewable energy systems in rural areas; Modelo de dimensionamento otimizado para sistemas energeticos renovaveis em ambiente rurais  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this research was to develop a methodology for sizing integrated renewable energy systems, useful for rural areas, using simulation and optimization tools developed in MATLAB 6.0. The sizing model produces a system with minimum cost and high reliability level, based on the concept of loss of power supply probability (LPSP) for consecutive hours. An optimization model is presented and three different sizing scenarios are calculated and compared, showing flexibility in the elaboration of different project conceptions. The obtained results show a complete sizing of the energy conversion devices and a long-term cost evaluation. (author)

2005-05-15

146

New High-Pressure Excitations in Parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

Raman and infrared spectroscopy of para-H{sub 2} to pressures in excess of 200GPa and to 8K using new ultrapure synthetic diamond anvils reveals numerous new vibrational excitations in the three high-pressure phases. Highly resolved Raman-active librons indicate differences in orientational ordering between phasesII and III, including evidence for changes within phaseII. The librons in phaseIII are strongly pressure dependent and reflect a substantial increase in ordering with pressure. Multiple vibrons in all three phases (I, II, and III) are observed. The results place new bounds on predicted crystal structures and dynamics of the dense molecular solid. {copyright} {ital 1997} {ital The American Physical Society}

1998-01-01

147

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor; Implantacao de um sistema eletronico para aquisicao de imagens neutrongraficas em tempo real no reator Argonauta do IEN/CNEN  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-15

148

Fusion of protoplasts with irradiated micro protoplasts as a tool for radiation hybrid panel in citrus;Fusao de protoplastos com microprotoplastos irradiados como ferramenta para painel hibrido de radiacao em citros  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work was to combine asymmetric somatic hybridization (donor-recipient fusion or gamma fusion) to microprotoplast-mediated chromosome transfer, as a tool to be used for chromosome mapping in Citrus. Swinglea glutinosa micro protoplasts were irradiated either with 50, 70, 100 or 200 gamma rays and fused to cv. Ruby Red grapefruit or Murcott tangor protoplasts. Cell colonies were successfully formed and AFLP analyses confirmed presence of S. glutinosa in both 'Murcott' tangor and 'Ruby Red' grapefruit genomes. (author)

2009-12-15

149

Evolutionary implications of morphogenesis and molecular patterning of the blind gut in the planarian Schmidtea polychroa  

British Library Electronic Table of Contents (United Kingdom)

The formation of a through-gut was a key innovation in the evolution of metazoans. There is still controversy regarding the origin of the anus and how it may have been either gained or lost during evolution in different bilaterian taxa. Thus, the study of groups with a blind gut is of great importance for understanding the evolution of this organ system. Here, we describe the morphogenesis and molecular patterning of the blind gut in the sexual triclad Schmidtea polychroa. We identify and analyze the expression of goosecoid, commonly associated with the foregut, and the GATA, ParaHox and T-box genes, members of which commonly are associated with gut regionalization. We show that GATA456a is expressed in the blind gut of triclads, while GATA456b is localized in dorsal parenchymal cells. Goo...

2011-01-01

150

Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...

2009-01-01

151

Acid pre-hydrolysis of biomass as a preparation process for its utilization as thermoelectric power plants fuel; Pre-hidrolise acida da biomassa como preparacao de combustivel para termoeletrica  

Energy Technology Data Exchange (ETDEWEB)

It is described a process of production of celulignin from biomass through acid pre-hydrolysis in continuous reactor made of advanced materials such as niobium, titanium and monel. The celulignin is a fuel of 28.50 MJ/kg of heating power. The utilization of this technology together with eucalyptus reforestation by vegetative propagation and high efficiency thermoelectric plant (triple cycle of steam turbine, gas turbine and MHD electrical generation) allow electric power production with competitive cost when compared to hydroelectric power. (author). 1 ref. 5 figs., 2 tabs

1990-12-31

152

A measurement of the parity-violating gamma-ray asymmetry in the neutron-proton capture  

Energy Technology Data Exchange (ETDEWEB)

The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.

2002-01-01

153

Purification and characterization of (-)(/sup 125/I)hydroxyphenylisopropyladenosine, an adenosine R-site agonist radioligand and theoretical analysis of mixed stereoisomer radioligand binding  

Energy Technology Data Exchange (ETDEWEB)

(-)-N6-(R-4-Hydroxyphenylisopropyl)adenosine (HPIA) was iodinated with NaI and trace /sup 125/I. Mono- and diiodinated reaction products and the starting material were separated by high pressure liquid chromatography and the structures of the reaction products were verified by NMR. (-)-N6-(R-Phenylisopropyl)adenosine (PIA), IHPIA, and I2HPIA decreased rat atrial contractility with ED50 values of 24, 28, and 33 nM, respectively. The contractile effects of these compounds were competitively blocked by theophylline (KI . 7.9 microM), but were not affected by adenosine deaminase. IHPIA also inhibited (-)isoproterenol-stimulated cyclic AMP accumulation in adipocytes with an ED50 (10 nM) and to an extent (83%) nearly identical to PIA. (/sup 125/I)HPIA prepared using carrier-free /sup 125/I bound to adenosine receptors on membranes from rat cerebral cortex, adipocyte ghosts, and heart ventricles. Binding was inhibited stereospecifically by PIA and by other adenosine ...

1984-11-01

154

cap alpha. -2 adrenergic receptor: a radiohistochemical study  

Energy Technology Data Exchange (ETDEWEB)

..cap alpha..-2 adrenergic agents have been shown to influence blood pressure, heart rate and other physiological and behavioral functions through interactions with adrenergic pathways within the central nervous system. Pharmacologically relevant ..cap alpha..-1 adrenergic receptors were biochemically characterized and radiohistochemically analyzed in intact tissue sections of the rat and human central nervous system. The anatomical distribution of the ..cap alpha..-2 receptors, labeled with the agonist (/sup 3/H)para-aminoclonidine, verified the concept that ..cap alpha..-2 receptors are closely associated with adrenergic nerve terminals and that ..cap alpha..-2 agents can influence autonomic and endocrine function through an action in the central nervous system. Since ..cap alpha..-2 agonists can influence sympathetic outflow, ..cap alpha..-2 binding sites were closely analyzed in the intermediolateral cell column of the thoracic spinal cord. The transport of ...

1984-01-01

155

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, an aluminum target ...

2010-05-01

156

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating from room temperature (RT) up to 500 deg. ...

2009-04-15

157

In vitro evaluation of herpes simplex virus type 1 thymidine kinase reporter system in dynamic studies of transcriptional gene regulation  

Energy Technology Data Exchange (ETDEWEB)

The herpes simplex virus type 1 thymidine kinase (HSV1-TK) reporter system is being used to directly and indirectly monitor therapeutic gene expression, immune cell trafficking and protein-protein interactions in various living animals. However, the issues of HSV1-TK enzyme stability in living cells and whether this reporter system is optimal for dynamic studies of gene expression events in genetic imaging have not be addressed. The purpose of the present study was to evaluate the application of this reporter system in dynamic studies of transcriptional gene regulation. To achieve this purpose, we established two tetracycline-inducible murine sarcoma cell lines, tetracycline-turn-off HSV1-tk-expressing cell line (NG4TL4/tet-off-HSV1-tk) and tetracycline-turn-off Luc-expressing cell line (NG4TL4/tet-off-Luc), to create an artificially regulated gene expression model in vitro. The dynamic transcriptional events mediating a series of doxycycline ...

2006-07-15

158

Ultratrace determination in high purity molybdenum and tungsten with ion chromatographic trace-matrix-separation. Pt. 2; Ultra trace analysis using ion chromatography. Ultraspurenanalytik in hochreinem Molybdaen und Wolfram mit ionenchromatographischer Spuren-Matrix-Trennung. Tl. 2; Ionenchromatographische Ultraspurenanalyse  

Energy Technology Data Exchange (ETDEWEB)

The use of high-performance ion exchangers allows a trace-matrix-separation (SMT) directly followed by an ion chromatographic (IC) separation of the analytes. Based on the principles described in Part 1, a combined procedure IC-SMT-IC for metallic impurities in Mo and W is presented. Up to 12 metal traces (Fe, Cu, Pb, Zn, Ni, Co, Cd, Ca, Mn, Sr, Mg and Ba) can be determined in one run with 35 min. A special method for traces of U and Th is also given. Detection limits are typically 10-100 ng g{sup -1} in the metal sample. (author). 14 refs.; 10 figs.; 6 tabs.

1992-01-31

159

The effect of trace elements on the fatigue behaviour of a carbide-hardened Fe-Ni-Cr alloy. Der Effekt von Spurenelementen auf das Zeitstandverhalten einer karbidverfestigten Fe-Ni-Cr-Legierung  

Energy Technology Data Exchange (ETDEWEB)

Fatigue tests were accomplished with a series of specimens doped with trace elements of a hardened Fe-Ni-Cr alloy, cast and hardened with intermetallic phases for determining the influence of these elements on the high temperature strength properties. The results of extensive fatigue tests show that even small contents of Te, Bi, Se, Pb, Tl and Zn considerably influence the life and creep processes especially after longer running periods, when added individually or combinedly. In contrast to this, the fatigue ductility is reduced by trace element additions even with short running periods. The order in which the metallic trace elements influence the fatigue properties nearly correlates with earlier work concerning Ni- and Co-superalloys. (orig.)

1993-01-01

160

Spectroscopy of {sup 25}Al and {sup 26,27,28}P using high-energy stripping reactions  

Science.gov (United States)

We report here results of an application of single-nucleon stripping reactions at high energies (65 MeV/u) in inverse kinematics to obtain spectroscopic factors. From measurements of the partial cross-sections for ground and excited states in residual nuclei formed in one-proton stripping reactions, single particle orbits and occupancies of light nuclei have been studied in the s-d shell. Single proton stripping cross-sections of {sup 25}Al and {sup 26,27,28}P on a Be target have been measured using the S800 spectrograph and the NaI(Tl) array at the NSCL. These results indicate that this technique may provide a general tool for the intermediate energy range analogous to transfer (pick-up) reactions at low-energy.

1998-12-21

161

Spectroscopy of "2"5Al and "2"6","2"7","2"8P using high-energy stripping reactions  

International Nuclear Information System (INIS)

We report here results of an application of single-nucleon stripping reactions at high energies (65 MeV/u) in inverse kinematics to obtain spectroscopic factors. From measurements of the partial cross-sections for ground and excited states in residual nuclei formed in one-proton stripping reactions, single particle orbits and occupancies of light nuclei have been studied in the s-d shell. Single proton stripping cross-sections of "2"5Al and "2"6","2"7","2"8P on a Be target have been measured using the S800 spectrograph and the NaI(Tl) array at the NSCL. These results indicate that this technique may provide a general tool for the intermediate energy range analogous to transfer (pick-up) reactions at low-energy.

1998-12-21

162

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

163

Practical superconductor development for electrical power applications  

Energy Technology Data Exchange (ETDEWEB)

Development of useful high-critical-temperature (high-{Tc}) superconductors requires synthesis of superconducting compounds; fabrication of wires, tapes, and films from these compounds; production of composite structures that incorporate stabilizers or insulators; and design and testing of efficient components. This report describes technical progress of research and development efforts aimed at producing superconducting components based on the Y-Ba-Cu, Bi-Sr-Ca-Cu, Bi-Pb-Sr-Ca-Cu, and Tl-Ba-Ca-Cu oxides systems. Topics discussed are synthesis and heat treatment of high-{Tc} superconductors, formation of monolithic and composite wires and tapes, superconductor/metal connectors, characterization of structures and superconducting and mechanical properties, and fabrication and properties of thin films. Collaborations with industry and academia are also documented. 10 figs.

1991-10-01

164

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

165

Luminescence dating  

International Nuclear Information System (INIS)

The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

166

Image diagnosis of parathyroid glands in chronic renal failure  

Energy Technology Data Exchange (ETDEWEB)

Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.

1983-07-01

167

Frequency mixing crystal  

Energy Technology Data Exchange (ETDEWEB)

In a laser system for converting infrared laser light waves to visible light comprising a source of infrared laser light waves and means of harmoic generation associated therewith for production of light waves at integral multiples of the frequency of the original wave, the improvement of said means of harmonic generation comprising a crystal having the chemical formula X.sub.2 Y(NO.sub.3).sub.5 .multidot.2 nZ.sub.2 o wherein X is selected from the group consisting of Li, Na, K, Rb, Cs, and Tl; Y is selected from the group consisting of Sc, Y, La, Ce, Nd, Pr, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Al, Ga, and In; Z is selected from the group consisting of H and D; and n ranges from 0 to 4.

1992-01-01

168

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

169

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

170

Luminescent unit computerization to research spectral characteristics of fine film alkali halide crystal  

International Nuclear Information System (INIS)

The fundamental optical absorption of ion crystals characterizes the creation of different free low energetic electronic excitation (the excitons and electron-hole pairs), but their straight registration is not possible because of incommensurable big absorption factor of alkali halide monocrystals. So to registration the spectrums of alkali halide monocrystal very fine layers are necessary. We have received fine films of Nal and KCl in system of KCl-Nal-KCl, KCl-KI-KCl on the base of universal vacuum post VUP-4, VUP-5 by thermal evaporation. A unique spectral unit has been created For this on the basic the SDL-2 complex. Complex consists of radiator, systems of condensers, monochromators MDR-12 and MDR-23, receivers of radiation, controller by unit. Connect and control of monochromators by means of IBM-compatible computer has been created. Kinematics schemes of monochromators provide consequent removing on output slot of monochromatic radiation in operating range of each diffraction ...

171

Proposal to neutralize acid fluids from wells in the Los Humeros, Pue., geothermal field; Propuesta para la neutralizacion de fluidos acidos provenientes de pozos del campo geotermico de Los Humeros, Pue.  

Energy Technology Data Exchange (ETDEWEB)

Neutralizing an acidic fluid consists of adding a sodium hydroxide solution to neutralize the H group of acids, therefore increasing the pH. The injection of sodium hydroxide has to be continuous and at a proper depth inside the well to protect against the corrosion of casing and surface equipment. Neutralization is a common practice used in geothermal fields, such as at The Geysers in the US and Miravalles in Costa Rica-places where aggressive fluids cause problems for extracting and using geothermal fluids commercially. A zone surrounding wells H-4, H-16 and H-29 in the northern section of the Los Humeros, Pue., geothermal field, known as the Colapso Central, has shown evidence of aggressively acidic fluids. Several wells drilled in the area had to be repaired, thus plugging and isolating the deepest production zones. Well H-43 was drilled two years ago in the northern zone of the field, and even though it is not located in the aggressive-fluid zone, the well presents mineralogical ...

2009-07-15

172

Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama. Wilsonville ACL R and D Facility material balance procedure. Topical Report No. 11  

Science.gov (United States)

Prior to 1978, the Wilsonville Advanced Coal Liquefaction facility material balance surrounded only the thermal liquefaction unit and involved analyses of only the slurry stream and individual gas streams. The distillate solvent yield was determined by difference. Subsequently, several modifications and additional process units were introduced to this single unit system. With the inclusion of the deashing unit in 1978 and the catalytic hydrogenation unit in 1981, the process has evolved into a sophisticated two-stage coal liquefaction process and has the potential for various modes of integration. This report presents an elemental balancing procedure and a simplified presentation format that is sufficiently flexible to meet current and future needs. The development of the elemental balancing technique and the relevant computer programs to handle the calculations have been addressed. This will be useful in modelling individual unit performance as well as determining the impact of each ...

1984-09-01

173

Thallium-technetium subtraction parathyroid imaging in patients having previous parathyroid surgery  

International Nuclear Information System (INIS)

Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck exploration, all had PT pathology accurately localized by preoperative scanning (7=single adenoma, 2=single hyperplastic gland, 1=two hyperplastic ...

1985-06-02

174

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear relationship exists between ...

1985-06-02

175

Phosphor plasters of CaSO{sub 4}:Dy on the courtyard wall of Djehuty's tomb (Luxor, Egypt)  

Energy Technology Data Exchange (ETDEWEB)

The X-ray diffraction (XRD) and environmental scanning electron microscopy (ESEM) analyses of plasters collected from the courtyard walls of Djehuty's tomb show anhydrite, calcite, dolomite, quartz, alkali feldspars and accessorial amounts of halite and illite. The external outer bed is mainly composed by anhydrite, since the original hydrous phases of gypsum plaster were desiccated during thirty centuries in the dry land environment of the Luxor area, under low relative humidity and high temperatures. The luminescence analyses by thermoluminescence (TL) and cathodoluminescence (CL) demonstrate as one plaster sample (m8), i.e., 95% anhydrite, displays a gigantic TL emission of 33 555 a.u. and a SEM/CL emission of 2319 a.u. maxima peak. The spectra CL also exhibits a 484 nm peak attributable to the classic {sup 4}F{sub 9/2}{yields}{sup 6}H{sub 15/2} transition circa 490 nm of Dy{sup 3+} and a 573 nm emission of Dy{sup 3+} masked in a ...

2008-02-15

176

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, ...

2008-05-22

177

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed CT images. The a-Se ...

2004-12-07

178

Update on erectile dysfunction treatment for aging men  

British Library Electronic Table of Contents (United Kingdom)

Resumen Estudios epidemiologicos recientes, muestran claramnete la incidencia de la disfuncion erectil con la edad. Por lo tanto, los profesionales sanitarios que se ocupan de las personas de edad avanzada, deberian preparar cuidadosamente el diagnostico y el abordaje de la disfuncion erectil. Es innegable que la introduccion de los inhibidores de la fosfodisterasa tipo 5 (PDE5Is) ha revolucionado el tratamiento de la disfuncion erectil. Los clinicos deberian conocer el potencial de los efectos adversos asociados con el uso de PDE5Is cuando se aconseja a los pacientes. Otras terapias suplementarias y de segunda/tercera linea para la disfuncion erectil, que incluyen las inyecciones intracavernosas, la aplicacion transuretral de medicacion, la testosterona, los sistemas de vacion peneano, la...

2008-01-01

179

Type tests to the automatic thermoluminescent dosimetry system acquired by the CPHR for personal dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal  

Energy Technology Data Exchange (ETDEWEB)

The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

2006-07-01

180

The importance of the treatment of the unsafe acts for the prevention of accidents in petrochemical industry; A importancia do tratamento dos atos inseguros para a prevencao de acidentes na industria petroquimica  

Energy Technology Data Exchange (ETDEWEB)

Due to the fact that, the workers' behavior is characterized by its complexity and diversity, this issue has been seen as a great 'black box' in discussions regarding the Management Systems of SHE. Associated with this issue other arises: How conscious people? How to engage them with the process? How to improve the risk control? How to motivate the prevention? Most of these responses are discussed in the Social and Human Sciences for many years. However, it is necessary to closer the technical-operational knowledge and the human aspects, applying in the organizations' daily work, to make the working environment more safe. The purpose of this study, therefore, is examining the possibility of reducing accidents through the identification and treatment of deviations (unsafe acts and unsafe conditions), cause the whole accident, be it serious or not, begins with a small deviation. It was used as a reference tool, the Behavior audit and it is based on ...

2008-07-01

181

The Muhlbauer method for pipeline risk management in onshore environment; O metodo de Muhlbauer para gerenciamento de risco em linhas de dutos em ambiente 'onshore'  

Energy Technology Data Exchange (ETDEWEB)

There are several methods for the risk assessment and risk management applied to pipelines, among them the Muhlbauer's Method. W. Kent Muhlbauer is an internationally recognized authority on pipeline risk management. He made a detailed identification about 300 distinct conditions that influence the risk assessment in pipelines and he proposed a score system that is known as method of Muhlbauer. The purpose of this model is to evaluate the public exposure to the risk and identify ways for management that risk in fact. The assessment is made by the attribution of quantitative values to the several items that influences in the pipeline risk. This paper approaches the Muhlbauer's basic model for risk assessment and management in pipelines. In the beginning, the basic model for risk assessment is presented, and methodology for pipelines in onshore environment is detailed. After, presents major items in risk assessment and this relative score. Finally, present the ...

2008-07-01

182

Systematic review and gamma radiosensitivity of medicinal plants: development of protocol for quality control; Revisao sistematica e radiossensitividade gama de plantas medicinais: desenvolvimento de protocolo para controle de qualidade  

Energy Technology Data Exchange (ETDEWEB)

The present study discusses the contribution of the adoption of more rigorous and objective criteria to the selection and analysis of information sources, leading to more scientific rigour when registering phytotherapic drugs. To this end, it is herein proposed the adoption of a previously tested and acknowledged methodology, namely the Systematic Revision, as a standard for phytotherapic drug analyses. In order to show differences brought about by the Systematic Revision during the registration procedures of phytotherapic drugs, the case of the Maytenus ilicifolia (known popularly in Brazil as 'espinheira-santa') is presented. As it is well known, the use of ionizing radiation is expanding, especially in medicine and pharmacy. Therefore, gamma radiation was applied to the microbiological quality control of phytotherapic matrices. Results indicated a positive contribution of Systematic Revision to the registration procedures of phytotherapic drugs, as well as the ...

2006-07-01

183

Reversible downregulation of endocrine and germinative testicular function (hormonal castration) in the dog with the GnRH-Agonist Azagly-Nafarelin as a removable implant "Gonazon"; a preclinical trial  

British Library Electronic Table of Contents (United Kingdom)

Downregulation of anterior pituitary GnRH-receptors by application of a slow release GnRH-implant offers an effective and reversible alternative to surgical castration of the male dog. Aim of the present study was to test the efficacy and the underlying mechanisms of a new non-biodegradable controlled-release device implant (Gonazon, Intervet, containing 18.5mg of the GnRH-agonist Azagly-Nafarelin). Eight male beagle dogs were implanted s.c. at the para-umbilical region. In four dogs implant removal was after 180 days (group 1), in the other four dogs after 365 days (group 2). Eleven weeks after implantation availability of LH was reduced (p<0.0001) by 70%. After an initial increase lasting for about 4 days, testosterone (T) and estradiol (E2) concentrations decreased (p<0.0001) to basal l...

2009-01-01

184

Produced water treatment using polymeric resins; Resinas polimericas para tratamento da agua produzida  

Energy Technology Data Exchange (ETDEWEB)

The treatment and disposal of oily waters from oil production and refining processes represent an important technological pass for attendance of the ambient legislation and to the politics of the Cia of search of the environmental excellence. The reuse or reinjection of the co-produced water has been considered an interesting strategical alternative, however, the water quality requirement for these processes demands a pretreatment step, considering the exit effluent from primary and secondary treatment processes currently used. This work presents resulted of the polymeric resin development for tertiary treatment of oily waters with low oil and grasses content and fine solids, including the dissolved fraction. These resins can adsorb, in reversible form, organic components. Its high adsorption capacity is determined by the polarity, superficial area, range of porosity and a wide distribution of particle size and pore. Another important characteristic is the possibility of its use in ...

2008-07-01

185

Problems of waste disposal in the handling of natural radioactive material not subject to authorisation  

International Nuclear Information System (INIS)

With the exception of some minerals, the specific activity of natural radioactive material is below 370 Bq/g, their handling thus not being subject to authorization or the duty of reporting according to section 4 para. 2 of the Radiological Protection Ordinance. Moreover, there is required no handling license for prospecting, mining and processing of radioactive minerals; they are subject to the procedures for the plans of operation of the mining laws of the Federal States. License-free handling of natural radioactive material may result in the production of radioactive waste, the disposal of which must be authorized according to sect. 47 of the Radiological Protection Ordinance if the specific activity exceeds the free amounts of column 4 in Table IV of Appendix IV by a factor of 10"-"4/g. This inconsistency is discussed by means of the following examples: (1) fly ash and slag from coal power plants, (2) flue dust from sintering plants, (3) red mud from aluminium ...

1980-05-01

186

New technology for the emulsification of petroleum residuals in water; Nueva tecnologia para la emulsificacion de residuales del petroleo en agua  

Energy Technology Data Exchange (ETDEWEB)

It turns out of interest to Comision Federal de Electricidad and Petroleos Mexicanos to reduce costs of fuel oil, reducing the viscosity of the residues petroleum of high vacuum distillation emulsifying these with water. The parameters that define the characteristics of the emulsions are mainly the relation of their components, viscosity, size and drop distribution and its stability. The experimental work began producing emulsions in form of lots, using samples of approximately 500 milliliters of vacuum residue. In this first stage, at different concentrations, were examined eight different surfactants, as well as combinations among them, also seven different stabilizers were used. With these tests it has been managed to identify the concentrations, as well as the most adequate relations of surfactants and stabilizers for the production of emulsions of vacuum residues in water. The size and drop distribution has been determined by means of an optical LEICA microscope, model DMLS, that ...

2001-07-01

187

Models comparative study for heat storage in fixed beds; Estudo comparativo de modelos para armazenamento de calor em leitos fixos  

Energy Technology Data Exchange (ETDEWEB)

This work presents comparative results of a numerical investigation of four possible models for the prediction of thermal performance of fixed bed storage units and their thermal design. These models includes Schumann's model, the radial dispersion model, a model that include both axial heat conduction in the fluid phase and admits thermal gradient in the solids particles and finally a two dimensional single phase model. For each of these models a computer code was written and tested to evaluate the computing time of same data and analyze any other computational problems. The tests of thermal performance included particle size, porosity, particle material, flow rate, inlet temperature and heat losses form tank walls and extremities. Dynamics behaviour of the storage units due to transient variation in either flow rate or inlet temperature was also investigated. The results presented include temperature gradients, pressure drop and heat storage. The results obtained are very ...

1991-07-01

188

Methodology to evaluate the energy associated to the industrial solid wastes: application in a metropolitan region of Campinas, Sao Paulo state, Brazil; Metodologia para avaliacao da energia associada ao residuo solido industrial: aplicacao a regiao metropolitada de Campinas  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is to the application of a methodology to evaluate the energy associated to the industrial solid wastes in the metropolitan region of Campinas. The methodological route proposed is: the characterization of the research area and the production/management of the industrial solid wastes; the energetic classification and the qualitative/quantitative research of the energy associated to the industrial solid wastes; and, the valuation of the applicability of the energetic utilization mechanisms proposed to the region. This methodology when applied at the Campinas metropolitan region proved to be valid and it resulted in a synthetically presentation of the social and environmental reality of the industrial sector and the destination of the wastes, as well as it indicated the potentialities related to the energetic utilization of the industrial solid waste in the region. With the obtained results it was shown the importance of the the production and the destination of the ...

2004-07-01

189

Humidity extraction and biomass chemical composition of the elephant-grass cultivated for energetic purposes; Extracao da umidade e composicao quimica da biomassa de capim-elefante cultivado para fins energeticos  

Energy Technology Data Exchange (ETDEWEB)

The experiment was conducted at the laboratory of Experimental Station of Instituto Agronomico de Campinas, in Piracicaba, SP, BR. The elephant-grass (Penissetum purpureum Schum) cv Guacu, with 6 months of development was chopped in a forage chopper regulated to cut biomass in pieces of 5 mm. 500 grams of chopped biomass was pressed in a hydraulic presser regulated for 60, 120, 180, 240 and 300 kg/cm{sup 2}. For the pressure of 60, 120, 180 and 240 kg/cm{sup 2} the presser was used in manual module, while, for the pressure of 300 kg/cm{sup 2} it was operated in the automatic module. The experiment was executed in randomized block design with 4 repetitions. When the pressure of 300 kg/cm{sup 2} was used it was extracted 21.78 % of the moisture of biomass, while the nitrogen percentage was little altered by press. (author)

2002-07-01

190

Explosion confinement system for exploitations by sublevels; Sistema de Confinamiento de Explosiones para Explotaciones por Subniveles  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to develop a explosion suppression system capable to confine and extinguish gas explosions of the type produced in sub level caving faces when blasting to the coal pillar. Existing systems, such as triggered barriers, were considered not to be valid because of size, weight, cost, and other operational constraints. The research activities have been focused in the development of a mixed water/air spray system that should be manually activated some second before blasting. Two prototypes have been developed and tested, the first one using nozzle operating at the standard ranges of pressure that are normally available in underground coal mines, and a second one based in high-pressure nozzles. In this case, bottles containing a pressurized air/water mixtures are required. The works carried out included theoretical studies, hydraulic nozzles characterization, and modelling of the explosion phenomena using the AutoReaGas code. Besides, extensive testing of the ...

1999-11-01

191

Evaluation of red mud as pozzolanic material in replacement of cement for production of mortars; Avaliacao da lama vermelha como material pozolanico em substituicao ao cimento para producao de argamassas  

Energy Technology Data Exchange (ETDEWEB)

Red mud is a by-product of the alkaline extraction of aluminum from the bauxite and represents a renewed environmental problem due the significant annual throughput by the plants. In the present work, the pozzolanic properties of Brazilian red mud fired at 600, 700, 800 and 900 deg C were investigated by monitoring lime consumption using DTA analysis and Brazilian standard methodology NBR 5772 (1992). Products and kinetics of hydration were determined in cement pastes produced with 5 and 15% red mud using x-ray diffraction and DTA analysis. Compressive strength and capillary absorption tests were realized on mortars constituted by 5, 10 and 15% red mud in replacement of cement. When calcined at 600 deg C, the red mud develops good pozzolanic properties, and the compressive strength of mortars produced with this waste meet values in accordance with regulatory standard. These results shown than red mud can be used, in partial replacement of cement, as new construction material to produce ...

2010-07-01

192

Development of polymeric coatings for submerse flexible lines; Desenvolvimento de revestimentos polimericos para linhas flexiveis submersas  

Energy Technology Data Exchange (ETDEWEB)

The major objective of this work is to seek for new solutions that can lead to significant lifetime improvement of submerse lines which experience severe wear processes on the polymeric layer coating used for protection of the touch down point (TDP) region. Four different materials were selected as possible candidates for the coating layer of this critical region. They are commercially available and posses well known processing technologies. The materials are two polymers: nylon 66 and polyacetal; and two composites: nylon 66 reinforced with 13 or 33% glass fiber. Stress-strain behavior was evaluated using two deformation rates in order to characterize the viscoelastic behavior proper of polymeric materials. It was observed that increasing the amount of glass fiber in the matrix leads to a stronger material and a consequent decrease of elongation to break. Additionally, abrasion tests were carried out using a Taber equipment in three distinct conditions. Results indicate that nylon was ...

2003-07-01

193

Development of a new tool for predicting water quality. Verification on a stretch of the river Ebro; Desarrollo de una nueva herramienta para la prediccion de la calidad del agua. Verificacion en un tramo del rio Ebro  

Energy Technology Data Exchange (ETDEWEB)

The Water Frame work Directive (December 2000) proposes integrated water management in regard to both quality and quality. A mathematical model has therefore been produced at the CEIT and EPTISA research centre, in collaboration with the Ebro Hydrographic. Confederation (CHE), to predict water quality and thus begin integrated management of it in the river basins. A description is given of the characteristics of the simulation tool. The hydraulic model is based on the numerical (weighted, four-point implicit) resolution of the complete Saint Venant equations. The quality model is based on the IWA River Water Quality Model Number 1 which has clear advantages (consistency, mass balance and easy integration with the biological models of the waste water treatment plants and the collector networks compared to traditional models. The experimental validation, which includes calibration in wintertime of the hydraulic and quality models most representative coefficients was assessed on the basis ...

2004-07-01

194

Development of DP (Dynamic Positioning) to pull-in sub sea pipelines; Utilizacao de barcos de manuseio de ancoras operando com DP (Dynamic Positioning) para arraste de dutos submarinos  

Energy Technology Data Exchange (ETDEWEB)

Sub sea pipeline construction at oil and gas fields, with high concentration of on-bottom facilities, becomes more difficult when mooring operations and pipeline approach to a congested platform have to be performed. One method that has often been applied in Brazil is the so-called 'DP (Dynamic Positioning) pull-in', where PETROBRAS owned pipelay Barge, BGL-1, is moored away from the congested area, while a DP anchor handler pulls the rigid pipeline from BGL-1 to a target near the platform. The method was conceived to avoid mooring operations near the congested platforms as well as to minimize risks due to the pipeline initiation process. Inside the congested area the initiation with aid of a 'dead-man' anchor on the sea bottom, which would be a more conventional solution, becomes impossible in most cases. This paper will discuss the engineering work required to perform the 'DP pull-in' as well as show the operational steps, from ...

2004-07-01

195

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable equipment, that allow the obtention of k Vp and m As combinations, ...

1996-12-31

196

Characterization of acai seeds as a feedstock for electricity generation via gasification; Caracterizacao do caroco de acai como insumo para geracao de eletricidade via gaseificacao  

Energy Technology Data Exchange (ETDEWEB)

This work presents an overview of the characterization physical-chemistry and energy of the aca pit used as input in process of generation of electricity through gasification. Acai pits analyses were accomplished with relationship to the acai pit drying, energy content, proximate and ultimate analyses, size, TGA experiments, bulk density. It was observed that the acai pit can be used as bioenergy but, it presents a low energy content (16,36 MJ/kg) in relationship that of the ' typical' biomass (21 MJ/kg ) and this is not due to the ash content that is very low (1,15%), but yes, the only composition that resembles each other more the Carbohydrates than to the typical composition of the usual biomass. The average diameter of 10 pits chosen at random was 9.5 mm. The acai pits have an angle of repose of {approx}20 degrees, making them ideal for feeding into gasification and combustion processes. (author)

2008-07-01

197

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

1999-07-01

198

An efficient method for 3-D pre stack migration in time reverse-time depth by using finite difference method; Um metodo eficiente para migracao pre-empilhamento 3-D em profundidade reversa no tempo pelo metodo das diferencas finitas  

Energy Technology Data Exchange (ETDEWEB)

Much of the current technology on 3D-prestack depth migration is based on the Kirchhoff method and the traveltime information needed for this purpose is obtained by the ray-theory approximation. The main motivation driving these options is to reduce computations but it can also have an adverse effect on the quality of results. Experience with real data indicates that the corresponding poststack data migrated by the reverse-time method often yields superior results. Considerable computational efficiency can be obtained by employing nonuniform coarse grid spacing during the reverse-time migration. We followed this strategy for developing a parallel scheme for doing 3D- prestack depth migration. However, we worked only on a small subset of shot gathers whose determined by the Quasi-Monte Carlo method. The results were indistinguishable from those obtained by using a much larger population of uniformly spaced shot gathers. We present examples of migration of 3-D data. (author)

1997-07-01

199

A decision support system to dynamic management of the scheduling workover rigs for onshore Potiguar Basin; Um sistema de apoio a decisao para o gerenciamento dinamico das sondas de producao terrestre da Bacia Potiguar  

Energy Technology Data Exchange (ETDEWEB)

The onshore Potiguar basin has nowadays around 5.000 artificial lifting petroleum wells, distributed into 80 fields located on the states of Rio Grande do Norte and Ceara, representing approximately 8% of the national oil production. For that, well maintenance service, realized by Workover Rigs, is essential to preserve the oil productivity of the reservoirs on these fields. However, as the number of rigs is lower than to the number of wells needing maintenance, the task of administrating the management of such equipment according to the demand created by the wells, generates an optimization problem. The decision for a rig intervention on a well depends on parameters such as flow rate, depth, wasted time on intervention, distance from the rig to the next well, type of operation, rig capacity, environmental risks, etc. The objective of this paper is to present an interactive Computational System for Support Decision to the optimized management of the wells attended by the rig fleet. ...

2004-07-01

200

First assessment of low- to medium-temperature geothermal reserves in 20 Mexican states; Primera estimacion de las reservas geotermicas de temperatura intermedia a baja en veinte estados de Mexico  

Energy Technology Data Exchange (ETDEWEB)

A first, partial, assessment is included of the low- to medium-temperature geothermal reserves in 20 Mexican States and their aggregate value. The assessment covers about 29.16% of the identified geothermal-surface manifestations in the public database. For reserve assessments, we use the volumetric method, supplemented with Montecarlo simulations and statistics, to quantify inherent uncertainties. Our estimations are presented on a state-by-state basis. We estimate the aggregated reserves of the 20 states as between 7.7 x 1016 and 8.6 x 1016 kJ, with 90% confidence. The most likely reservoir temperatures range between 60-180 degrees Celsius, with a mean of 111 degrees Celsius. Such massive amounts of recoverable energy-and the associated temperatures-are potentially important for the economic development of nearby localities and the nation. [Spanish] En este trabajo se hace una primera estimacion, parcial, de las reservas geotermicas de temperatura intermedia a baja de Mexico. La ...

2009-07-15

201

Ultratrace determination in high-purity molybdenum and tungsten with ion chromatographic trace-matrix-separation. Pt. 1; Selection and optimization of the separation step. Ultraspurenanalytik in hochreinem Molybdaen und Wolfram mit ionenchromatographischer Spuren-Matrix-Trennung. Tl. 1; Auswahl und Optimierung des Trennschritts  

Energy Technology Data Exchange (ETDEWEB)

Known trace-matrix-separation and enrichment procedures for the refractory metals Mo and W use very time-consuming batch-techniques. This paper presents the application of a quasicontinuous liquid chromatographic (LC) technique as a step towards automated ultratrace separation. The anionic peroxo complexes from Mo(VI) and W(VI) are used for the trace-matrix-separation. Optimization of the peroxide concentration permits a complete removal of all cationic analyte traces on the HPLC-suitable cation exchanger Nucleosil SA. The high chromato-graphic efficiency also allows a direct ion chromatographic separation of the removed traces. This leads to conclusions about the contribution of the analyte traces on the trace-matrix-separation column and the limits of determination. (author). 13 refs.; 12 figs.; 5 tabs.

1991-11-20

202

Ternary oxide nanostructures and methods of making same  

Energy Technology Data Exchange (ETDEWEB)

A single crystalline ternary nanostructure having the formula A.sub.xB.sub.yO.sub.z, wherein x ranges from 0.25 to 24, and y ranges from 1.5 to 40, and wherein A and B are independently selected from the group consisting of Ag, Al, As, Au, B, Ba, Br, Ca, Cd, Ce, Cl, Cm, Co, Cr, Cs, Cu, Dy, Er, Eu, F, Fe, Ga, Gd, Ge, Hf, Ho, I, In, Ir, K, La, Li, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, Os, P, Pb, Pd, Pr, Pt, Rb, Re, Rh, Ru, S, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Tc, Te, Ti, Tl, Tm, U, V, W, Y, Yb, and Zn, wherein the nanostructure is at least 95% free of defects and/or dislocations.

2009-09-08

203

Sodium to sodium carbonate conversion process  

Energy Technology Data Exchange (ETDEWEB)

A method is described for converting radioactive alkali metal into a low level disposable solid waste material. The radioactive alkali metal is atomized and introduced into an aqueous caustic solution having caustic present in the range of from about 20 wt % to about 70 wt % to convert the radioactive alkali metal to a radioactive alkali metal hydroxide. The aqueous caustic containing radioactive alkali metal hydroxide and CO{sub 2} are introduced into a thin film evaporator with the CO{sub 2} present in an amount greater than required to convert the alkali metal hydroxide to a radioactive alkali metal carbonate, and thereafter the radioactive alkali metal carbonate is separated from the thin film evaporator as a dry powder. Hydroxide solutions containing toxic metal hydroxide including one or more metal ions of Sb, As, Ba, Be, Cd, Cr, Pb, Hg, Ni, Se, Ag and Tl can be converted into a low level non-hazardous waste using the thin film evaporator of the invention. 3 ...

1997-10-14

204

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

205

Radiation methods in research of ancient monuments  

Energy Technology Data Exchange (ETDEWEB)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray fluorescence analysis has ...

2000-11-15

206

Radiation methods in research of ancient monuments  

International Nuclear Information System (INIS)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray fluorescence analysis has been chosen as the ...

2000-11-15

207

Quantification of "2"3"5U and "2"3"8U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional ...

2011-06-01

208

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma photons. Time ...

2000-01-01

209

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron activation analysis and analyses of natural ...

1994-09-01

210

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the theoretical background and ...

2010-01-01

211

NOAA National Status and Trends Program Tenth Round Intercomparison for Trace Metals in Marine Sediments and Biological Tissues. National Status and Trends Program for marine environmental quality: Technical memo  

Energy Technology Data Exchange (ETDEWEB)

A total of forty participants were included in the exercise, including NOAA, USEPA, state, Australian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant: a contaminated marine sediment from the vicinity of New York Bay and a freeze dried mussel (Mytilus edulis) from Charlottenlund, Denmark. Laboratories were also asked to analyze two certified reference materials NIST SRM 1566a, and NRC BCSS-1. The elements to be determined were Al, Cr, Fe, Ni, Cu, Zn, As, Se, Ag, Cd, Sn, Hg, and Pb for both matrices, plus Be, Si, Mn, Sb, and Tl for the sediments. An accepted mean and confidence interval were calculated for each analyte in the two unknown samples. Laboratory biases were identified and an overall rating of superior, good, fair or others was assigned to each laboratory.

1996-11-01

212

NMR study of Ba2"+ ion motion in one-dimensional ionic conductor with hollandite-type structure  

International Nuclear Information System (INIS)

Ionic motion of a divalent cation, Ba"2"+, in a single crystal of Ba-Al-priderite was studied using "2"7Al as an NMR probe. Several pairs of satellite peaks due to electric quadrupole interaction were observed superposed on broad satellite tails on both sides of the main peak of "2"7Al. These peak pairs indicate the existence of some stable three-dimensional configurations of Ba"2"+ ions in the structure, and the broad shoulders show a random substitution of Al"3"+ for Ti"4"+ sites. The temperature dependence of the spin-lattice relaxation time T"*_l measured in the temperature range from 161 to 1176 K was analyzed by a curve fitting method on the assumption that there are two types of Ba"2"+ ions. An activation energy of 0.47 eV was obtained for the motion of Ba"2"+ ions which are easy to move, and a broad distribution of activation energies spread over a range from 0.95 to 2.45 eV was obtained for the motion of Ba"2"+ ions which form a three-dimensional honeycomb ...

213

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

214

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

215

Measurement of electron energy fluence spectra from electron beam therapy machines  

Energy Technology Data Exchange (ETDEWEB)

A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. CYLTRAN, a coupled electron-photon Monte Carlo transport code, was used to produce ...

1984-01-01

216

Luminescence of CaGa2Se4:Eu crystals  

International Nuclear Information System (INIS)

We have studied photoluminescence and thermoluminescence (PL and TL) in CaGa2Se4:Eu crystals in the temperature range 77-400 K. We have established that broadband photoluminescence with maximum at 571 nm is due to intracenter transitions 4f6 5d-4f7 (8S7/2) of the Eu2+ ions. From the temperature dependence of the intensity (log I-103/T), we determined the activation energy (Ea = 0.04 eV) for thermal quenching of photoluminescence. From the thermoluminescence spectra, we determined the trap depths: 0.31, 0.44, 0.53, 0.59 eV. The lifetime of the excited state 4f6 5d of the Eu2+ ions in the CaGa2Se4 crystal found from the luminescence decay kinetics is 3.8 ?sec. (authors)

217

IAEA RESEARCH CONTRACTS SECOND ANNUAL REPORT. Technical Reports Series No. 9  

Science.gov (United States)

Summaries are presented for those research contracts which expired between December 31, 1960 and December 31, 1981. Topics covered include: factors controlling distribution of fission products in biosphere, non-destructive methods of evaluating the U/sup 235/ and Pu content of irradiated fuel elements, studies of contamination in local marine resources, tracer studies of anemia, non-destructive analysis of irradiated fuel elements using a flux integrating monitor, mechanism of proteolysis of I/sup 131/-labeled fibrinogen, radiosensitivity of spermatogonia of Drosophila melel elements by gamma scanning, uptake and loss of radioactive material by marine bacteria, factors which influence the movement of radioactive strontium from soils to plants, biological concentration of fission products in mollusks from water, decay scheme of Tl/sup 210/, calcium balance in metabolic bone disease, development of radioactive drugs with special reference ...

1962-01-01

218

Comparative action spectrum for ultraviolet light killing of mouse melanocytes from different genetic coat color backgrounds  

International Nuclear Information System (INIS)

The photobiology of mouse melanocyte lines with different pigment genotypes was studied by measuring colony-forming ability after irradiation. The cell lines were wild-type black (melan-a) and the mutants brown (melan-b) and albino (melan-c). Four lamps emitting various UV wavelengths were used. These were germicidal (UVC, 200-280 nm), 82.3% output at 254 nm, TL01 (UVB, 280-320 nm), 64.2% at 310-311 nm, FS20, broadband with peak output at 312 nm and Alisun-S (UVA, 320-400 nm), broadband with peak output at 350-354 nm. Appropriate filtration reduced the contaminating UVC to nonlethal levels for the longer waverange lamps. It is clear from these studies that, in pigment cells, monochromatic results cannot predict polychromatic responses and that cell death from solar irradiations is a complex phenomenon that depends on more than DNA damage. (author).

1997-01-01

219

Importance of the planning activities, cutting, handling and analysis of the nuclei of oil well drilling; Importancia de las actividades de planificacion, corte, manejo y analisis de los nucleos de perforacion de pozos petroleros  

Energy Technology Data Exchange (ETDEWEB)

In the geologic formation where the oil deposits are located, diverse types of rocks perform functions as structural elements, storage containers for hydrocarbon water and calorific energy, as well as impermeable barriers and transport means of the energy and the fluids. Among the most important properties that are used to describe these functions are the porosity, the permeability, the compressibility of the pores volume, the formation resistivity factor, the saturation exponent, the velocity of acoustic waves P and S, the relative permeability, the capillary pressures, the elastic constants and other mechanical properties, the thermal expansion, coefficient, the thermal conductivity, the thermal diffusivity and the specific heat. The execution of an ample variety of activities related to the stages of exploration, location, evaluation and development of the oil deposits, depends strongly on having a good knowledge of the magnitude and the spatial variability of these properties. The ...

2007-07-01

220

Use of sting-response techniques for simulate diagnostics in human esophagus; Uso de tecnicas estimulo-respuesta para simular diagnosticos en esofago humano  

Energy Technology Data Exchange (ETDEWEB)

In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation of the attenuation of the radiations that takes place in the ...

2003-07-01

221

Use of coal as fuel for chemical-looping combustion with Ni-based oxygen carrier  

Energy Technology Data Exchange (ETDEWEB)

Chemical-looping combustion is an indirect combustion technology with inherent separation of the greenhouse gas CO{sub 2}. The feasibility of using NiO as an oxygen carrier during chemical-looping combustion of coal has been investigated experimentally at 800-960{degree}C in the present work. The experiments were carried out in a fluidized bed, where the steam acted as the gasification-fluidization medium. Coal gasification and the reaction of oxygen carrier with the water gas take place simultaneously in the reactor. The oxygen carrier particles exhibit high reactivity above 900{degree}C, and the dry basis concentration of CO{sub 2} in the exit gas of the reactor is nearly 95%. The flue gas composition as a function of the reactor temperature and cyclic reduction number is discussed. At 800-960{degree}C, the dry basis concentration of CO{sub 2} in the flue gas presents a monotonously increasing trend, whereas the dry basis concentration of CO, H{sub 2}, and CH{sub 4} decreases ...

2008-12-15

222

The two means method for the attenuation coefficient determination of archaeological ceramics from the North of Parana; Metodo dos dois meios para a determinacao do coeficiente de atenuacao de ceramicas arqueologicas do norte do Parana  

Energy Technology Data Exchange (ETDEWEB)

This work reports an alternative methodology for the linear attenuation coefficient determination ({mu} {rho}) of irregular form samples, in such a way that is not necessary to consider the sample thickness. With this methodology, indigenous archaeological ceramics fragments from the region of Londrina, north of Parana, were studied. These ceramics fragments belong to the Kaingaing and Tupiguarani traditions. The equation for the {mu} {rho} determination employing the two mean method was obtained and it was used for {mu} {rho} determination by the gamma ray beam attenuation if immersed ceramics, by turns, in two different means with known linear attenuation coefficient. By the other side, {mu} theoretical value was determined with the XCOM computer code. This code uses as input the ceramics chemistry composition and provides an energy versus mass attenuation coefficient table. In order to validate the two mean method validation, five ceramics samples of thickness 1.15 cm and 1.87 cm ...

1997-12-31

223

Subsidence monitoring in the Cerro Prieto geothermal field, B.C., Mexico; Monitoreo de la subsidencia en el campo geotermico de Cerro Prieto, B.C., Mexico  

Energy Technology Data Exchange (ETDEWEB)

Since 1977, precise leveling surveys have been carried out to determine whether there have been vertical terrain displacements and the subsidence speed rate in the Cerro Prieto Geothermal field area. The elevation contours for each leveling show since 1962 that there was a basin that involves the geothermal field. The differences in the last three levelings show a generalized subsidence between Cerro Prieto (BN 10049) and Imperial faults (BN CD-14). [Spanish] A partir de 1977 se realizan trabajos de nivelacion de precision, con el fin de conocer si existen desplazamientos verticales del terreno y cual es la velocidad de subsidencia que existe en el area del Campo Geotermico de Cerro Prieto. Las configuraciones de cotas para cada uno de los anos nivelados, muestran que desde 1962 existe una cuenca que incluye al campo geotermico; la diferencia de cotas obtenidas en las tres ultimas nivelaciones, indican una subsidencia generalizada entre la Falla Cerro Prieto (BN ...

1999-04-01

224

Self-construction of a solar water heater; Calentador solar de agua de auto-construccion  

Energy Technology Data Exchange (ETDEWEB)

In this work a flat receiver of self construction is shown with relatively low cost and easy manufacture, but with a thermal efficiency superior to 40% for applications at temperatures less than 60 degrees Celsius, that allows satisfying international standards in this respect. The heater has been matter of study in open courses distributed in the Universidad Autonoma de la Ciudad de Mexico (UACM) oriented to that the participants construct their own system, in addition to its installation and tests. The obtained results have been excellent. The massive use of efficient solar receivers of self-construction can truly help to the decreasing of the gas discharges of greenhouse effect. [Spanish] En este trabajo se presenta un captador plano de auto construccion con relativamente bajo costo y facil manufactura, pero con un rendimiento termico superior a 40% para aplicaciones a temperatura menos de 60 grados centigrados que le permite satisfacer estandares ...

2009-07-01

225

Occupational exposure to benzene: a prevention program for employees and contractors; PPEOB - Programa de Prevencao a Exposicao Ocupacional ao Benzeno para Empregados Proprios e Contratados  

Energy Technology Data Exchange (ETDEWEB)

PETROBRAS/TRANSPETRO Pipelines and Terminals has 500 regular employees and 5.064 out sourced workers in its Southeast Division. The out sourced employees work through 125 contracts involving a wide range of activities such as maintenance, operational, pipeline launching , engineering, administrative and auxiliary services. Among these workers, 200 people are subjected to benzene occupational exposure, which might be present in the products we transport in our pipelines. Benzene is recognized as a carcinogen according to ACGIH and Brazilian Ministry of Labour regulation NR- 15. Exposure to benzene in an uncontrolled way, be it chronic or sharp, may affect the worker's health such as: hematological alterations, neoplasys, neurobehavior alterations. Our program PPEOB (acronym in Portuguese for benzene occupational exposure prevention program) involved the work force and fosters health by anticipation, recognition, evaluation and control of the situations that may result in ...

2004-07-01

226

Methodology for sizing, energy analysis and selection of equipment for a biomass gasifier to drive an internal combustion engine; Metodologia de dimensionamento, analise energetica e selecao de equipamentos de um gaseificador de biomassa para o acionamento de um motor de combustao interna  

Energy Technology Data Exchange (ETDEWEB)

Alter both oil crisis, of 1973 and 1979, a bad effect of the elevated costs and continuously increment of the oil prices was noted, for this reason, the interest for renewable energies sources widely available in developing countries was increased. All over the world, governments have formulated main objectives for energies savings and search for friendly technologies, taking into account the effects related with the environment. The imminent scarcity of fossil fuels has made humanity the rational use of primary energies, as a result of these; new plants with improved technology have been conceived taking into account energy savings and efficiency improvement. In this context, biomass gasification technologies are important, since they consist in techniques of parallel production of electricity and heat from just one fuel. This work consists in the development of a gasifier down draft of 100 kW for an internal combustion engine, which includes its sizing process and its energy ...

2006-07-01

227

Energy generation for sustainable development with innovation technology and utilization of biomass residue; Geracao de energia para o desenvolvimento rural sustentavel com inovacao tecnologica de aproveitamento de biomassa residual  

Energy Technology Data Exchange (ETDEWEB)

In the present work, the introduction of alternative energy of biogas in agricultural communities for the sustainable development was studied through exploitation of residual biomass and also getting as by-product the biological fertilizer. A fast composting of the domestic residue with the organic was made possible where part of this residue after processing was taken together with effluent to the biodigestor. The bibliographical research on the processes of generation of biogas, about composting and the equipment for processing had been carried through. The projects Engineering with the use of computational tools had been developed with the Software Super Pro 4,9 Design and ORC GPEC 2004 by our research group. Five case studies had been elaborated, where different scenes related with our innovation, that uses of the residue for the composting together with domestic effluent for digestion. Several economic parameters were obtained and our work proved the viability about the use of ...

2004-07-01

228

Development of bioenergy technology for rural micro mills production of milk, ice and bio fertilizer; Desenvolvimento de tecnologia de bioenergia rural para micro usinas de producao de leite, gelo e bio fertilizante  

Energy Technology Data Exchange (ETDEWEB)

The generation of thermal energy is the great importance for the agribusiness of dairy industry to conservation the quality of milk, taking into account that the electricity is the main source currently used for the thermal energy input. The small agribusiness dairy industry currently practiced in Brazil faces several problems related to the cost of electricity and the distance of rural properties of networks of power. In the current scenario of Brazilian dairy production, there is need for the generation of cold for the milk cooling, and also the heat for the production of hot water around 50 deg C to 60 deg C and also for cleaning of equipment used for milk production and processing. The main objective of this study is the modeling and simulation of integrated recovery process of solid waste, effluents and bioconversion. The specific project objectives are: comparison study of options and technological routes of low cost material for power generation using conventional and innovative ...

2008-07-01

229

Decay of H{sub 2}{sup -} anions in solid parahydrogen by quantum tunneling: observations of electron bubbles  

Energy Technology Data Exchange (ETDEWEB)

Decay mechanism of H{sub 2}{sup -} anions produced by {gamma}-ray or X-ray radiolysis of solid para-H{sub 2} (p-H{sub 2}) has been studied using high-resolution ESR spectroscopy in the temperature range between 2.7-6.6 K. The results can be summarized as follows; First, the decay rate constant of the H{sub 2}{sup -} anion is not proportional to initial yields of reactive species such as H radical and cation but proportional to concentrations of HD and D{sub 2} impurities in p-H{sub 2}. Second, ESR spectra assigned as electron bubbles were observed in solid p-H{sub 2} containing large amount of HD or D{sub 2} (11 mol %), while they were not observed in pure solid p-H{sub 2}. Third, the decay rate constant of the H{sub 2}{sup -} anion increases with the decrease in temperature between 2.7-5 K, while it decreases with the decrease between 5-6.6 K. Fourth, the decay of the H{sub 2}{sup -} anion is suppressed by addition of ortho-H{sub 2} (o-H{sub 2}) impurity. The ...

1998-02-01

230

[sup 123]I-MIBG myocardial scintigraphy in diabetic patients. Association with autonomic neuropathy  

Energy Technology Data Exchange (ETDEWEB)

[sup 123]I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed in 20 diabetic patients (NIDDM) and 8 control subjects to investigate the association between clinical autonomic nerve dysfunction and myocardial accumulation of MIBG. We used coefficient variance of R-R interval (CV[sub R-R]) as a index of the autonomic neuropathy and categorized diabetes into two groups (CV[sub R-R][>=]2.0: non-autonomic neuropathy. CV[sub R-R]<2.0: autonomic neuropathy). In planar imaging studies, heart to mediastinum MIBG uptake ratio (H/M) was calculated on both early and delayed images. The washout ratio of [sup 123]I-MIBG in the heart (%WR) was also obtained using myocardial tracer activity on the both images. Mean value of these indices in diabetic group did not reveal any significant difference with the value in the control group. On the SPECT images, low uptake was observed in the posterior-inferior wall with normal uptake of [sup 201]Tl in diabetic ...

1994-09-01

231

Wilsonville Advanced Coal Liquefaction Research and Development Facility technical progress report. Run 244 with Illinois 6 coal  

Science.gov (United States)

This report presents the operating results for Run 244 at the Advanced Coal Liquefaction R and D Facility in Wilsonville, Alabama. This run was made in an all-distillate Integrated Two-Stage Liquefaction (ITSL) mode using Illinois 6 coal from the Burning Star mine. The primary objective was to demonstrate the effects of temperature programming an aged catalyst batch on the ITSL product slate, especially on the net C/sub 1/-C/sub 5/ gas production and hydrogen consumption. Other objectives were to demonstrate the effect of fresh catalyst addition and to age the catalyst batch for an extended run with catalyst addition and withdrawal. Run 244 began on 4 July 1983 and continued through 27 September 1983. During this period, 182.9 tons of coal was fed in 1872 hours of operation. Seven special product workup material balances and two hydrotreater balances were defined, and the results are presented herein. From 27 to 30 September, 7.4 tons of Wyodak (Clovis Point mine) subbituminous coal ...

1984-05-01

232

The present state of nuclear medicine practice in Japan; A report of the 3rd nationwide survey in 1992  

Energy Technology Data Exchange (ETDEWEB)

The Subcommittee for Surveillance of Nuclear Medicine Practice has implemented a survey for actual nuclear medicine practice in Japan every 5 years. This article reports on the third survey implemented during a one-month period in June 1992. Questionnaires were sent to all 1256 facilities employing radiopharmaceuticals in routine practice, and 1162 (92.5%) answered. In vivo nuclear medicine examinations per day were performed in 6600 cases. SPECT accounted for 19.4%, as compared with 7.1% in the 1987 survey. According to organs, the frequency of examination for the cerebrospinal region was 3.2 and 2.2 times higher than that in the 1982 and 1987 surveys, respectively, whereas for the thyroid gland it was 0.6-fold and 0.7-fold that of these surveys. The proportion of bone scintigraphy was the highest (24.5%), followed by tumor scintigraphy (14.1%) and myocardial scintigraphy (11.9%). The frequency of myocardial and cerebral blood flow scintigraphy was dramatically increased as compared ...

1993-09-01

233

SR 97 - Alternative models project. Discrete fracture network modelling for performance assessment of Aberg  

Energy Technology Data Exchange (ETDEWEB)

As part of studies into the siting of a deep repository for nuclear waste, Swedish Nuclear Fuel and Waste Management Company (SKB) has commissioned the Alternative Models Project (AMP). The AMP is a comparison of three alternative modeling approaches for geosphere performance assessment for a single hypothetical site. The hypothetical site, arbitrarily named Aberg is based on parameters from the Aespoe Hard Rock Laboratory in southern Sweden. The Aberg model domain, boundary conditions and canister locations are defined as a common reference case to facilitate comparisons between approaches. This report presents the results of a discrete fracture pathways analysis of the Aberg site, within the context of the SR 97 performance assessment exercise. The Aberg discrete fracture network (DFN) site model is based on consensus Aberg parameters related to the Aespoe HRL site. Discrete fracture pathways are identified from canister locations in a prototype repository design to the surface of ...

1999-08-01

234

RangerMaster{trademark}: Real-time pattern recognition software for in-field analysis of radiation sources  

Energy Technology Data Exchange (ETDEWEB)

RangerMaster{trademark} is the embedded firmware for Quantrad Sensor`s integrated nuclear instrument package, the Ranger{trademark}. The Ranger{trademark}, which is both a gamma-ray and neutron detection system, was originally developed at Los Alamos National Laboratory for in situ surveys at the Plutonium Facility to confirm the presence of nuclear materials. The new RangerMaster{trademark} software expands the library of isotopes and simplifies the operation of the instrument by providing an easy mode suitable for untrained operators. The expanded library of the Ranger{trademark} now includes medical isotopes {sup 99}Tc, {sup 201}Tl, {sup 111}In, {sup 67}Ga, {sup 133}Xe, {sup 103}Pa, and {sup 131}I; industrial isotopes {sup 241}Am, {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 40}K, {sup 60}Co, {sup 232}Th, {sup 226}Ra, and {sup 207}Bi; and nuclear materials {sup 235}U, {sup 238}U, {sup 233}U, and {sup 239}Pu. To accomplish isotopic identification, a simulated ...

1998-12-31

235

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal projections ...

2006-01-15

236

Optically stimulated luminescence and thermoluminescence in CVD diamond and dosimetric evaluation in fields of ionizing radiation; Luminiscencia opticamente estimulada y termoluminiscencia en diamante DQV y evaluacion dosimetrica en campos de radiacion ionizante  

Energy Technology Data Exchange (ETDEWEB)

The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it presents the polluted ...

2006-07-01

237

Neutron cross section measurements using the ORELA: "6"0Ni(n,x), "4"0Ca(n,x), "2"2Ne(n,#gamma#), "1"8"9Os(n,n'), /sup 186,187,188,189/Os(n,x), "1"8"9Os(n,#gamma#), /sup 148,149,150/Sm(n,#gamma#), "1"7"9Ta(n,#gamma#), /sup 86,87,88/Sr(n,x), "4"0Ar(n,x), the stable tellurium isotopes (n,#gamma#) and "2"0"5Tl(n,x). Progress report, September 1, 1984-August 31, 1985  

International Nuclear Information System (INIS)

The research performed during this reporting period (9/1/84 to 8/31/85) resulted in: (1) publication of three papers; (2) presentation of an invited paper to the conference on ''Neutron-Nucleus Collisions: A Probe of Nuclear Structure''; (3) presentation of three contributed papers at APS meetings; and (4) preparation of three manuscripts, two of which are in the process of internal review at the Oak Ridge National Laboratory and are included with this report, and the third is being typed as this report is being written. The publications and papers deal with topics in both nuclear structure and astrophysics. Our efforts to study the systematic behavior of the optical model potential in the energy region just above neutron binding has been made substantially more reliable with the publication of a paper which discusses the accuracy of the methods used to average the measured scattering matrix. In the area of stellar nucleosynthesis, comparison of our model calculations and measured ...

238

High-Performance, Superparamagnetic, Nanoparticle-Based Heavy Metal Sorbents for Removal of Contaminants from Natural Waters  

Energy Technology Data Exchange (ETDEWEB)

We describe the synthesis and characterization of superparamagnetic iron oxide nanoparticle based heavy metal sorbents with various surface chemistries that demonstrate an excellent affinity for the separation of heavy metals in contaminated water systems (i.e. spiked Columbia river water). The magnetic nanoparticle sorbents are prepared from an easy to synthesize iron oxide precursor, followed by a simple, one-step ligand exchange technique to introduce the organic surface functionality of interest chosen to target either specific or broader classes of heavy metals. Functionalized superparamagnetic nanoparticles are excellent sorbent materials for the extraction of heavy metal contaminants from environmental and clinical samples since they are easily removed from the media once bound to the contaminant by simply applying a magnetic field. These engineered magnetic nanoparticle sorbents have an inherently high active surface area (often > 100 m2/g), allowing for increased binding ...

2010-06-01

239

Dose coefficients for intakes of radionuclides via contaminated wounds.  

Science.gov (United States)

The NCRP Wound Model, which describes the retention of selected radionuclides at the site of a contaminated wound and their uptake into the transfer compartment, has been combined with the ICRP element-specific systemic models for those radionuclides to derive dose coefficients for intakes via contaminated wounds. These coefficients can be used to generate derived regulatory guidance (i.e., the activity in a wound that would result in an effective dose of 20 or 50 mSv, or in some cases, a organ-equivalent dose of 500 mSv) and clinical decision guidance (i.e., activity levels that would indicate the need for consideration of medical intervention to remove activity from the wound site, administration of decorporation therapy or both). Data are provided for 38 radionuclides commonly encountered in various activities such as nuclear weapons, fuel fabrication or recycling, waste disposal, medicine, research, and nuclear power. These include 3H, 14C, 32P, 35S, 59Fe, 57,58,60Co, 85,89,90Sr, ...

2011-05-01

240

Distributions of "1"3"7Cs, "2"0"1T1, "2"0"3Hg, "2"0"3Pb and "5"7Co in a rat hepatoma model. Comparison with "6"7Ga  

International Nuclear Information System (INIS)

The distribution of carrier-free "2"0"3Pb-acetate, "2"0"3HgCl_2, "5"7Cocl_2, "1"3"7CsCl and "2"0"1TlCl was investigated in rats bearing thigh-implanted Morris 7777 hepatomas. Viable and nonviable tumor tissue was collected in order to determine the relative affinities of the radiopharmaceutical for these tissues. The animals were sacrificed at 4, 24, 48, 72 and 96 hrs following intravenous injection. Washout of the radioisotope from the viable tumor tissue was rapid, the maximum concentration being reached on or before 4 hrs following injection. In contrast, residual activity within the nonviable tumor tissue decreased much more slowly and in some cases even increased with time. Viable tumor-to-muscle and nonvialbe tumor-to-muscle ratios for "2"0"3Pb, "2"0"3Hg and "5"7Co were comparable to the analogous ratios reported for "6"7Ga. However, none of these isotopes approached "6"7Ga as a potential tumor imaging agent because the large ratios were the result of low ...

241

Determination of sodium in biological samples by instrumental neutron activation analysis  

International Nuclear Information System (INIS)

Sodium is one of the most essential elements needed for metabolic processes amongst human beings. It is consumed in the form of sodium chloride but it is also present in edible plant leaves. Sodium is mostly analyzed by flame photometric method, a destructive and time consuming technique. Sodium has been determined in some green leave vegetables samples-palak, radish, khatta palak (ambat chuka), chaulai leaves, chauli bean covers and its seeds by instrumental neutron activation analysis. The method involves irradiation of samples with thermal neutrons from "2"4"1Am-Be source and counting "2"4Na activity (half life 15 hr) from the reaction "2"3Na(n,#gamma#) "2"4Na. Activity due to 1.37 MeV photopeak was counted with a NaI(Tl) crystal coupled to gamma ray spectrometer. Green leaves of the vegetables were thoroughly washed, dried at constant temperature and powdered. Bowen's Kale powder was used as standard for measuring sodium abundances. About 2g each of samples and ...

1981-05-01

242

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, the PGS system was ...

2007-09-21

243

Description of work vadose drilling at the 1301-N and 1325-N facilities, 100-NR-1 operable unit  

Energy Technology Data Exchange (ETDEWEB)

This description of work (DOW) details the field activities associated with the sampling of the vadose zone soils beneath the 1301-N and 1325-N cribs and trenches and will serve as a field guide for those performing the work. These activities are undertaken pursuant to the Hanford Federal Facility Agreement and Consent Order (Ecology et al., 1994a) Milestone M-16-94-01H-Tl and the June 30, 1994 Milestone Change Request M-16-94-02 (Ecology et al., 1994b). Three vadose zone borings, 1301-N-1, 1301-N-2, and 1325-N-1, will be constructed to investigate the vertical and horizontal distribution of radionuclide contamination in sediments beneath the cribs and trenches. The boreholes are also intended to intersect subsurface areas that may have been contaminated by dangerous wastes, i.e., metals, in effluent disposed during past operation of the facilities. This limited field investigation will provide data for the evaluation of remedial alternatives. Data from the ...

1994-08-01

244

Cellular dosimetry: Absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments  

Energy Technology Data Exchange (ETDEWEB)

The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, {sup 86}Rb, {sup 89}Sr, {sup 90}Y, {sup ...

1994-02-01

245

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of individual fission products to deduce fission-product yields. ...

1997-05-01

246

ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation  

International Nuclear Information System (INIS)

Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, 45Rh-103M, 45Rh-105M, 45Rh-105, 45Rh-106, ...

247

Voltage and reactive power control by means of static compensators of vars in electric power systems; Control de voltaje y potencia reactiva mediante compensadores estaticos de Vars en sistemas electricos de potencia  

Energy Technology Data Exchange (ETDEWEB)

In this thesis a study is made of the of voltage characteristics and reactive power control in the transmission network of the Electric Power Systems (EPS) with static compensators of VARs (SCVs). The necessity of voltage and reactive power control and the application of SCVs as a solution means for three representative operation stages of the EPS, considering balanced operation conditions and fundamental frequency is analyzed: Operation in the presence of incremental voltage changes, quasi-stationary operation or steady state and behavior at the occurrence of big disturbances. The application of SCVs to systems of integral transmission is in general a closed loop control system, reason why the analysis of the interaction of the system EPS-SCV is considered as an essential part of the voltage and reactive power control study. Firstly, the response analysis of the control loop is made for incremental voltage changes, representing the power system by means of its equivalent of Thevenin ...

1987-07-01

248

Proposal of procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions; Proposta de procedimentos para evitar erros em radioterapia baseados em licoes aprendidas de exposicoes acidentais  

Energy Technology Data Exchange (ETDEWEB)

In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the incidents. The results ...

2007-07-01

249

Mechanodynamical analysis of nickel-titanium alloys for orthodontics application; Analise mecanodinamica de ligas de niquel-titanio para aplicacao ortodontica  

Energy Technology Data Exchange (ETDEWEB)

Nickel-titanium alloys may coexist in more than one crystalline structure. There is a high temperature phase, austenite, and a low temperature phase, martensite. The metallurgical basis for the superelasticity and the shape memory effect relies in the ability of these alloys to transform easily from one phase to another. There are three essential factors for the orthodontist to understand nickel-titanium alloys behaviour: stress; deflection; and temperature. These three factors are related to each other by the stress-deflection, stress-temperature and deflection-temperature diagrams. This work was undertaken with the objective to analyse commercial nickel-titanium alloys for orthodontics application, using the dynamical mechanical analyser - DMA. Four NiTi 0,017 X 0,025'' archwires were studied. The archwires were Copper NiTi 35 deg C (Ormco), Neo Sentalloy F200 (GAC), Nitinol Superelastic (Unitek) and NiTi (GAC). The different mechanodynamical properties such as ...

2002-07-01

250

The Prognostic Significance of p53, Bcl-2, Cytokeratin 20 and Ki-67 in Primary Superficial Papillary Transitional Bladder Carcinoma  

International Nuclear Information System (INIS)

Identification of factors that determine individual patient risk for recurrence and progression in superficial papillary carcinoma of the bladder is a subject of extensive research as it would be a major outcome in patient management. It has been well recognized that traditional prognostic markers as tumor grade and stage are not accurate enough in predicting biological behavior. A large number of markers have been investigated as potential prognostic factors and relatively few can help in predicting outcome. Material and Methods: Forty-nine cases undergoing complete transurethral resection for primary superficial papillary transitional cell carcinoma were subjected to clinicopathologic evaluation as well as immunohistochemical staining for p53, bcl-2, cytokeratin 20 and Ki-67. The CAS-200 image analyzer was used to estimate the Ki-67 labeling index. Results: Recurrence was observed in 19 cases (38.8%) and progression in 7 cases (14.3%) with a median followup of 49 months (range 24-84 ...

2003-03-01

251

Study of the inorganic constituents in different species of Casearia medicinal plant collected in distinct regions of the Atlantic Forest, SP State, Brazil; Estudo sobre os constituintes inorganicos presentes em diferentes especies da planta medicinal do genero Casearia coletadas em regioes distintas da Mata Atlantica, SP  

Energy Technology Data Exchange (ETDEWEB)

The use of medicinal plants in the treatment of diseases has increased significantly in the last years, as has research concerning chemical characterization of these plants. In this study, inorganic constituents were determined in leaves and in extracts from three medicinal plant species of the Casearia genus (C. sylvestris, C. decandra and C. obliqua) collected in distinct regions of the Atlantic Forest, SP. The elemental compositions of the soils in which these plants were grown were also determined. Traditionally, these plants are used due to their antiinflammatory, antiacid, antiseptic and cicatrizing properties. The antiulcer and the antitumor activities of the Casearia genus and its capacity to neutralize snake and bee venoms, have also been scientifically confirmed. The analytical methodology used was neutron activation analysis. Long and short irradiation periods of the samples and the standards were carried out at IPEN's IEA-R1 nuclear research reactor. In the leaf K ...

2006-07-01

252

Solution conformations of CaCl sub 2 and Ca(NO sub 3 ) sub 2 complexes of chiral tetramethyl 18-crown-6 macrocycles: A 1D and 2D sup 1 H and sup 13 C NMR investigation  

Energy Technology Data Exchange (ETDEWEB)

One- and two-dimensional NMR techniques have been used to investigate the solution structures of (2S,6S,11S,15S)-2,6,11,15-tetramethyl-1,4,7,10,13,16-hexaoxacyclooctadecane (I) and (2R,3R,11R,12R)-2,3,11,12-tetramethyl-1,4,7,10,13,16-hexaoxyacyclooctadecane (II) macrocycle complexes of CaCl{sub 2} and Ca(NO{sub 3}){sub 2} in CDCl{sub 3}. Previous chiroptical studies of these and similar crown complexes by circularly polarized luminescence (CPL), total luminescence (TL), and circular dichroism (CD) spectroscopy have shown that the macrocycle asymmetric carbons in these complexes constrain the ring such that the sense of the ring twist in the S chiral ring complexes is opposite to that in the R chiral ring complexes. These studies have also shown that there is an added chirality element in the di- and trivalent (alkaline earth and lanthanide metal, respectively) nitrate complexes of I and II associated with the twist of the nitrate anions relative to one another as ...

1989-10-04

253

DECAY OF Ta$sup 177$ AND Lu$sup 177$ TO LEVELS IN Hf$sup 17$$sup 7$  

Science.gov (United States)

The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gamma spectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, 113.0 249.7, and 321.3 kev are correct ...

1961-10-15

254

The technical-economic potential of thermal energy saving in hospitals; El potencial tecnico-economico de ahorro de energia termica en hospitales  

Energy Technology Data Exchange (ETDEWEB)

The hospitals are important consumers of energy. At the General Hospital of Zone (HGZ) N of the IMSS in Aguscalientes (HGZ N . IMSS Ags.), the diesel oil is the main fuel that is used to satisfy the requirements of thermal energy of the hospital. According to the data collected by this author, this fuel represented in 2001, 75% of its total energy consumption and the 67.9% of its total costs in energy that ascended to $396.131 (December 2001 Dollars) Since this last amount represents an important percentage of the total expenses of the hospital (29.367 million dollars) it is important to determine the technical-economic possibilities of thermal energy saving of the hospital. The HGZ N 1 IMSS Ags. is located in a ampler conglomerate where the IMSS units are located, such as, the regional laundry, the sport unit, the center of social security, the familiar medicine unit N 1 and the hospital. Nevertheless departing from the installation of the electrical systems and the provision of steam ...

2001-07-01

255

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the dosimetric properties of the chip cards, the raw material of the globe ...

256

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -I. 6. Neutronics Analyses for Beamline Upgrades to the High Flux Isotope Reactor  

International Nuclear Information System (INIS)

The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...

2001-06-17

257

Geological evolution of the center-southern portion of the Guyana shield based on the geochemical, geochronological and isotopic studies of paleoproterozoic granitoids from southeastern Roraima, Brazil; Evolucao geologica da porcao centro-sul do escudo das Guianas com base no estudo geoquimico, geocronologico e isotopico dos granitoides paleoproterozoicos do sudeste de Roraima, Brasil  

Energy Technology Data Exchange (ETDEWEB)

This study focuses the granitoids of center-southern portion of Guyana Shield, southeastern Roraima, Brazil. The region is characterized by two tectonic-stratigraphic domains, named as Central Guyana (GCD) and Uatuma-Anaua (UAD) and located probably in the limits of geochronological provinces (e.g. Ventuari-Tapajos or Tapajos-Parima, Central Amazonian and Maroni-Itacaiunas or Transamazon). The aim this doctoral thesis is to provide new petrological and lithostratigraphic constraints on the granitoid rocks and contribute to a better understanding of the origin and geo dynamic evolution of Guyana Shield. The GCD is only locally studied near to the UAD boundary, and new geological data and two single zircon Pb-evaporation ages in mylonitic biotite granodiorite (1.89 Ga) and foliated hastingsite-biotite granite (1.72 Ga) are presented. These ages of the protholiths contrast with the lithostratigraphic picture in the other areas of Cd (1.96-1.93 Ga). Regional mapping, petrography, ...

2006-07-01

258

Fifteen years of seismic monitoring at the Las Tres Virgenes, BCS, geothermal field; Quince anos de monitoreo sismico en el campo geotermico de Las Tres Virgenes, BCS  

Energy Technology Data Exchange (ETDEWEB)

Seismic monitoring at the Las Tres Virgenes, BCS, geothermal field started in 1992 with an analog station of vertical components detecting a large number of earthquakes of varying magnitudes. In February 1993, a seismic network was installed, composed of six digital stations DR-2000-with S-6000 and S-5000 sensors and three registration channels (N-S, E-W and vertical). This was the basis for the development of a program to correct arrival-time data for P and S waves due to instrument drift. From January to April 1994 and May to August 1995, based on the 170 seismic events recorded, a velocity model was proposed. From December 1995 to July 1996, seismic data were processed and interpreted, and zones of occurrence were determined for events according to magnitude and the predominant noise in the field. From September 2003 to December 2004, 10 seismic stations (permanent and temporary) were installed and monitored and it was concluded the most active fault system was El Volcan. From ...

2009-07-15