WorldWideScience
1

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material ...

2005-10-23

2

LiF:Mg, Cu, P TL detectors with adjustable energy responses  

Energy Technology Data Exchange (ETDEWEB)

When used for tissue-equivalent monitoring, the thermoluminescence material LiF:Mg, Cu, P shows an 'under-response' to low-energy photons. This paper explores a new way to increase its low-energy response effectively, and to make it adjustable to some extent, by adding elements with high Z{sub eff}. At the same time its excellent thermoluminescente (TL) performance is maintained. (author).

1991-11-14

3

Idaho Explosives Detection System  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Explosives Detection System was developed at the Idaho National Laboratory (INL) to respond to threats imposed by delivery trucks potentially carrying explosives into military bases. A full-scale prototype system has been built and is currently undergoing testing. The system consists of two racks, one on each side of a subject vehicle. Each rack includes a neutron generator and an array of NaI detectors. The two neutron generators are pulsed and synchronized. A laptop computer controls the entire system. The control software is easily operable by minimally trained staff. The system was developed to detect explosives in a medium size truck within a 5-min measurement time. System performance was successfully demonstrated with explosives at the INL in June 2004 and at Andrews Air Force Base in July 2004.

2005-12-01

4

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

5

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

6

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum ...

2004-12-07

7

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of ...

1998-06-01

8

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

9

Anomalous solvent extraction behavior of astatine  

International Nuclear Information System (INIS)

We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).

10

{open_quotes}Pre-residue{close_quotes} light charged particles from {sup 28}Si+{sup 165}Ho and {sup 16}O+{sup 197}Au, {sup 208}Pb fusion  

Energy Technology Data Exchange (ETDEWEB)

Proton and alpha particle spectral shapes and multiplicities have been measured in coincidence with evaporation residues from {sup 28}Si+{sup 165}Ho and {sup 16}O + {sup 197}Au, {sup 208}Pb fusion reactions. Our experiments used 145 to 220 MeV {sup 28}Si and 115 and 140 MeV {sup 16}O beams produced with the Stony Brook LINAC. ER`s were separated using an electrostatic deflector and detected with large area surface barrier detectors. Light charged particles were detected at forward and backward angles with fourteen single NaI detectors. In the context of the statistical model, charged particle spectra yield information about emission barriers and compound nucleus equilibrium level densities. These are significant ingredients in calculations determining fission timescales from other observables such as pre-scission neutron multiplicities or fusion-evaporation excitation functions. Results will also be compared to analyses of ...

1993-10-01

11

The E = mc{sup 2} exhibition  

Energy Technology Data Exchange (ETDEWEB)

The goal of this DOE-supported exhibition is to demystify Einstein`s formula E = mc{sup 2} by illustrating the interchangeability of matter (m) and energy (E), c{sup 2} being the exchange rate. The exhibition has two major parts, {open_quotes}matter into energy{close_quotes} and {open_quotes}energy into matter{close_quotes}, plus a video to connect them. {open_quotes}Matter into energy{close_quotes} has now been completed and has been placed on the museum floor. Positrons from a {sup 22}Na source are annihilated to produce gamma rays that are caught in NaI detectors. The viewer can alter the alignment of the detectors and observe the consequences for the rates of single and coincident counts. The viewer can also observe the effects of placing absorbers in front of the counters. Prototype explanatory graphics were placed around the exhibit and those will probably be changed after we have some experience with their ...

1995-08-01

12

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial ...

2003-09-15

13

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude ...

2000-01-01

14

A Radiation Laboratory Curriculum Development at Western Kentucky University  

Science.gov (United States)

We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and Radiation Biophysics). Our goal is ...

2009-03-10

15

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

16

The 8{pi}LP Project: A 4{pi} light charged particle detection array at LNL  

Energy Technology Data Exchange (ETDEWEB)

A 4{pi} detection system sensitive to light charged particles is being developed at the Laboratori Nazionali di Legnaro (LNL) for the study of reaction mechanisms at energies up to 20 AMeV. The array consists of 262 {Delta}E-E telescopes covering 90% of 4{pi}. Each telescope is made of a 300 {mu}m passivated silicon detector and a 15 mm (or 5 mm) CsI(Tl) crystal read by a photodiode. The system will be operational in the Spring of 1997 and the first experiments will run in the second half of 1997.

1996-12-31

17

Nondestructive analysis for "2"3"2U and decay progeny in animal tissues  

International Nuclear Information System (INIS)

Direct determination of "2"3"2U and its decay products in animal tissues appears to be feasible using an intrinsic Ge(Li) diode detector (for energies of 5-100 keV) and a NaI(Tl) anticoincidence-shielded Ge(Li) diode for higher-energy gamma photons. The detection sensitivity for "2"3"2U and "2"2"8Th is 0.03 and 0.01 nCi, respectively, using a 300-min counting time.

1977-05-01

18

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...

19

show expanded view - NAI: Ask an Astrobiologist  

Science.gov (United States)

I understand that you cannot answer truthfully because of the the janap 146e otherwise you would be commiting treason but please give a more intelligent ...

20

Suzanne Baldwin ? Profile ? Directory ? NASA Astrobiology  

Science.gov (United States)

The unified web presence for the NASA Astrobiology Program which includes the NASA Astrobiology Institute (NAI), Astrobiology Science and Technology for ...

21

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.

2008-05-22

22

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

23

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

24

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

25

Pharmacokinetic parameters for thallium (I)-ions in man  

Energy Technology Data Exchange (ETDEWEB)

The pharmacokinetics of Tl/sup +/ were studied in 9 patients who underwent myocardial scintigraphy with /sup 201/Tl/sup +/. The time course of the /sup 201/Tl/sup +/ concentration fitted to an open two-compartment model. Using previously published dialysance values the influence of hemodialysis on Tl/sup +/ elimination was calculated. Hemodialysis in Tl/sup +/ intoxications should be moderately effective.

1983-05-01

26

Measurement of electron energy fluence spectra from electron beam therapy machines  

Energy Technology Data Exchange (ETDEWEB)

A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. CYLTRAN, a coupled electron-photon Monte Carlo transport code, ...

1984-01-01

27

Regulation of Na(+)-K+ pump activity in contracting rat muscle.  

UK PubMed Central (United Kingdom)

1. In rat soleus muscle, high frequency electrical stimulation produced a rapid increase in intracellular Na+ (Na+i) content. This was considerably larger in muscles contracting without developing tension...Full Text Available

1997-09-15

28

An analytic representation of the radial distribution of dose from energetic heavy ions in water, Si, LiF, and NaI  

International Nuclear Information System (INIS)

An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.

1989-09-01

29

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

30

As time goes by? The fallacy of thrombolysis in STEMI networks  

British Library Electronic Table of Contents (United Kingdom)

Primary percutaneous coronary intervention (PPCI) is superior to thrombolysis (TL) as reperfusion therapy in ST-elevation myocardial infarction (STEMI). TL is a rapidly available, but semi-effective therapy (effective reperfusion in 50% of patients only), whereas PPCI is a potentially delayed, but highly effective therapy (effective reperfusion in >90%). Since TL loses its efficacy beyond 2?3?h after symptom onset, it is a significant reperfusion alternative to PPCI in early presenters only. The individual decision to treat an early presenter with PPCI or TL requires the evaluation of the time delay between potential start of TL or PPCI, the PCI-related delay (PRD). PRD is greatest, if TL is given in the prehospital setting. Until now, prehospital TL as the most rapidly available reperfusi...

2011-01-01

31

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray ...

2008-05-22

32

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

33

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron activation analysis and analyses of natural ...

1994-09-01

34

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the ...

2010-01-01

35

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

36

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

37

Equilibrium and pre-equilibrium emissions in proton-induced reactions on "2"0"3","2"0"5Tl  

International Nuclear Information System (INIS)

In this study, the excitation functions for the reactions "2"0"3Tl(p, n)"2"0"3Pb, "2"0"5Tl(p, 3n)"2"0"3Pb, "2"0"3Tl(p, 2n)"2"0"2Pb, "2"0"5Tl(p, 4n)"2"0"2Pb, "2"0"3Tl(p, 3n)"2"0"1Pb, "2"0"5Tl(p, 5n)"2"0"1Pb, "2"0"3Tl(p, 4n)"2"0"0Pb and "2"0"5Tl(p, 6n)"2"0"0Pb have been calculated using pre-equilibrium and equilibrium reactions mechanisms. Calculated results based on hybrid model, geometry-dependent hybrid model and cascade-exciton model have been compared with the experimental data. (author)

2009-02-01

38

Infrared bleaching of the thermoluminescence of four feldspars  

International Nuclear Information System (INIS)

This paper studies the effect upon the thermoluminescence (TL) signal of four feldspar samples of exposing them to infrared stimulation, as occurs during infrared-stimulated luminescence (IRSL) measurement. Together with pulse annealing measurements these results are used to show which part of the TL signal is removed by exposure to IR and which part is directly related to the IRSL signal that is observed. When the samples are preheated prior to measurement in order to remove any low-temperature (< 200"oC) TL signals, a linear relationship is observed between the amount of TL that is lost and the IRSL light sum that is produced. The IRSL light sum is consistently four times larger than the amount of TL that is lost. Three possible explanations are proposed for this, but no conclusive evidence could be obtained to support any of them. A close similarity is observed in the pulse ...

1995-06-01

39

Production of 'no-carrier-added' "2"0"1Tl  

International Nuclear Information System (INIS)

A procedure has been developed for producing a radiopharmaceutically pure ''no-carrier-added'' "2"0"1Tl. The procedure is based on irradiating enriched metallic thallium (> 96% "2"0"3Tl) targets with approx. 30 Mev protons, separating "2"0"1Pb by co-precipitation with SrSO_4 from sulphuric acid solution, and extracting "2"0"1Tl (after its in-growth) with butyl acetate from a hydrochloric solution. The average overall yield of "2"0"1Tl is approx. 92%. The radioactive concentration of the product exceeds 2 mCi/mL; radionuclide impurities-"2"0"0Tl <= 0.5%; "2"0"2Tl <= 0.1%; "2"0"3Pb <= 0.02%; inactive impurities (#mu#g/mL)-Tl < 2, Sr < 1, Fe < 0.25, Cu < 0.05; pH within the range 5-8. The product is sterile, apyrogenic, and suitable for clinical application. (author).

40

Non-linearity of pre-dose response and its effects on TL dating  

Energy Technology Data Exchange (ETDEWEB)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-15

41

Non-linearity of pre-dose response and its effects on TL dating  

International Nuclear Information System (INIS)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-01

42

NAI: Year 4 Annual Report - NASA Astrobiology Institute  

Science.gov (United States)

His talk was based on the suggestion that life on Earh has been a long but accelerating ..... a New Class of Submarine Hydrothermal System"; April 29, 2002 , ..... of media personnel, including radio, television, newspapers, and magazines. ...... "The Birth of Stars and Planets" (Denver Museum of Nature and Science ...

43

Separation of "2"0"3Pb from Tl_2O_3 target material using a hydrous zirconium oxide column with application to "2"0"1Tl preparation  

International Nuclear Information System (INIS)

Lead 203 has been used as a tracer for lead in the field of nuclear medicine for several years. It is produced in a cyclotron usually by proton or deuteron bombardment of a thallium target principally by the p,n or d,2n reaction on "2"0"3Tl or the p,3n or d,4n reaction on "2"0"5Tl. Several different methods have been reported for the separation of "2"0"3Pb from the thallium target. These generally involve a combination of precipitation and solvent extraction techniques. A new method has been developed for the separation of Pb from Tl using ion exchange chromatography over hydrous zirconium oxide (HZO). Lead is taken up by this inorganic ion exchanger at pH > 3 whereas Tl(I) is not. Lead can subsequently be eluted with acid of pH 1-1.5. The recovery of "2"0"3Pb has been approximately 75% and the Tl impurity level has not been in excess of 10 ppm. Reference is made to the ...

44

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO{sub 4}  

Energy Technology Data Exchange (ETDEWEB)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The ...

2005-10-15

45

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO_4  

International Nuclear Information System (INIS)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL ...

2005-10-01

49

Myocardial perfusion SPECT in patients after myocardial infarction: Comparison of "2"0"1Tl and dual-isotope protocol (rest "2"0"1Tl/stress "9"9"mTc tetrofosmin)  

International Nuclear Information System (INIS)

The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI

1998-08-01

50

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to ...

1991-06-01

51

Luminescence characteristics for the detection of radiation treatment of shellfish by using isolated minerals  

International Nuclear Information System (INIS)

Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray ...

52

Purification of cyclotron-produced {sup 203}Pb for labeling Herceptin  

Energy Technology Data Exchange (ETDEWEB)

A simple and rapid procedure was developed for the purification of cyclotron-produced {sup 203}Pb via the {sup 203}Tl(d,2n) {sup 203}Pb reaction. A Pb(II) selective ion-exchange resin, with commercial name Pb Resin from Eichrom Technologies, Inc., was used to purify {sup 203}Pb from the cyclotron-irradiated Tl target with excellent recovery of the enriched Tl target material. The purified {sup 203}Pb was used to radiolabel the monoclonal antibody Herceptin. The in vitro and in vivo properties of the {sup 203}Pb radioimmunoconjugate were evaluated.

2005-04-01

53

Luminescence characteristics of LiCaAlF6:Eu phosphor  

British Library Electronic Table of Contents (United Kingdom)

A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

2007-01-01

54

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, ...

2007-09-21

55

Thallium-201 yields and excitation functions for the lead radioactivities produced by irradiation of natural thallium with 15-60 MeV protons  

International Nuclear Information System (INIS)

Excitation functions, production yields and radionuclidic purities are described for "2"0"1Tl production by the "2"0"3Tl(p,3n) "2"0"1Pb #-># "2"0"1Tl and "2"0"5Tl(p,5n)"2"0"1Pb#->#"2"0"1Tl nuclear reactions. The yields (mCi g"-"1 cm"2/#mu#A-hr) of the parent "2"0"1Pb(9.4hr), as well as the radiocontaminants "2"0"0Pb(21.5hr), sup(202m)Pb(3.62 hr), "2"0"3Pb(52.1 hr) and sup(204m)Pb(1.115 hr) were measured by irradiating a stack of thin natural Tl foils with protons from the 76-in isochronous cyclotron at the Crocker Nuclear Laboratory. The "2"0"1Tl thick-target yield (mCi/#mu#A hr) was calculated for different target thicknesses and corresponding incident proton energies. The excitation functions for the "2"0"3Tl(p,3n)"2"0"1Pb and "2"0"5Tl(p,5n)"2"0"1Pb reactions were measured in the 15-60-MeV ...

56

Calculation of the knight shift in the system CaCdsub(1-x)Tlsub(x) by using relativistic APW wave functions  

International Nuclear Information System (INIS)

For the intermetallic system CaCdsub(1-x)Tlsub(x), 0 <= x <= 1, the Knight shift Ksub(s) of the Cd-NMR and the Tl-NMR were calculated as a function of x, Ksub(s) = Ksub(s)(x). The theoretical investigations were performed on the basis of relativistic augmented-plane-wave (RAPW) band-structure calculations for the boundary phases CaCd and CaTl respectively, and by using the rigid band model for the ternary phases. The density of states and the matrix elements of the relativistic hyperfine operator for electron states at the Fermi surface were calculated in detail. The obtained values were compared with nonrelativistic calculations. The effect of using different exchange potentials was studied for Ksub(s)(Tl). For the Cd-NMR the relativistic effects enhance the nonrelativistic results by a factor of about 1.4. The theoretical value for the Knight shift is smaller than the experimental one by a factor of 1.13. The band ...

57

Analysis of thermoluminescence glow curves of minerals sphene and epidote for radiation damage studies  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence (TL) properties of sphene and epidote are of interest in studies related to their radiation damage. Natural and artificially induced TL of these minerals has, therefore, been investigated. Both minerals exhibit complex glow curves with several overlapping peaks. The Tsub(m) -Tsub(STOP) thermal cleaning procedure has revealed three peaks in the ..gamma.. ray induced glow curve of each mineral. That these peaks obey second order kinetics was indicated by the continuously slanting structure of the Tsub(m)-Tsub(STOP) curve. The TL parameters E and s have been calculated using (i) the initial rise method, and (ii) the glow-peak shape method. In general, the values of E calculated by the first method are found to be higher than those from the second. The TL curve-fitting method is also applied in order to calculate these parameters and to serve as a cross-check on the results.

1986-01-01

58

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...

1999-07-01

59

Interactions of metal cations with anionic groups on the cell Wall of the macroalga vaucheria sp.  

Energy Technology Data Exchange (ETDEWEB)

The aim of this article was to investigate the interactions of metal cations in aqueous solutions with the biomass of the freshwater macroalga Vaucheria sp. This problem is important when elaborating new applications of biosorption, e.g. the production of mineral feed additives for livestock from the biomass of algae enriched with microelement ions. Potentiometric titration was applied as a quick and cheap screening test to search for new efficient biosorbents. It revealed a variety of functional groups capable of cation exchange on the macroalgal surface, including carboxyl, phosphate, hydroxyl or amino groups. Fourier transform infrared spectroscopy on natural and chromium-loaded Vaucheria sp. confirmed that carboxyl groups played a dominant role in the biosorption. The study also showed that Ca(II), Na(I), K(I), and Mg(II) ions were released from the biomass after biosorption of Cu(II), Mn(II), Zn(II), and Co(II) ions, indicating that ion exchange was a key ...

2010-06-15

60

Spectrochemical analysis using infrared multichannel detectors  

CERN Document Server

Spectrochemical analysis using infrared multichannel detectors

2007-01-01

61

CZT Detector and HXI Development at CASS/UCSD  

CERN Document Server

CZT Detector and HXI Development at CASS/UCSD

2006-01-01

62

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)  

CERN Document Server

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)

2011-01-01

63

Suppression of afterglow in CsI:Tl by co doping with Eu"2"+-II: Theoretical model  

International Nuclear Information System (INIS)

The mechanism for afterglow suppression in codoped CsI:Tl,Eu reported in the preceding paper was investigated by combined radioluminescence and thermoluminescence experiments. Model rate equations informed by these experiments were employed to simulate afterglow. It was found that codoping with europium introduces deep electron traps, with room-temperature glow peaks, that effectively scavenge the electrons from shallow traps associated with thallium, thus suppressing afterglow in the time domain of tens of milliseconds.

2006-03-15

64

SEM and EDXS analysis of the reaction products of compounds A[sub x]M[sub 6]X[sub 8] (A = Tl, K; M = V, Ti; X = S, Se) with I[sub 2]/CH[sub 3]CN and H[sub 2]O. [TlVS; TlVSe; TlTiS; TlTiSe; KVS; KVSe; KTiS; KTiSe  

Energy Technology Data Exchange (ETDEWEB)

The ternary transition metal chalcogenides A[sub x]M[sub 6]X[sub 8] (A = Tl, K; M = V, Ti; X = S, Se) build up a three dimensional framework with large hexagonal channels running parallel to the crystallographic c-axis. The electropositive elements thallium or potassium are confined within these channels. It is possible to remove the Tl or K atoms via a chemical redox reaction with an I[sub 2]/CH[sub 3]CN solution or with H[sub 2]O. Using SEM it is demonstrated that the host matrix V[sub 6]S[sub 8]'' is only slightly affected by the redox agent. In contrast the host matrix Ti[sub 6]Se[sub 8]'' of Tl[sub x]Ti[sub 6]Se[sub 8] reacts with the I[sub 2]/CH[sub 3]CN solution. The results of the EDXS analyses clearly show that the removal of the electropositive elements proceeds only along the large channels and not through the host matrix. (orig.)

1994-05-01

65

Effects of ischemic-like insult on myocardial /sup 201/Tl accumulation  

Energy Technology Data Exchange (ETDEWEB)

Despite extensive clinical use of thallium-201 (/sup 201/Tl) for myocardial imaging, the effect of ischemia on myocardial accumulation and release of /sup 201/Tl independent of flow has not been fully defined. Therefore, myocardial accumulation of /sup 201/Tl in response to ischemic-like myocardial injury was assessed in vitro using the cultured fetal mouse heart preparation. Cultured fetal mouse hearts (n . 311) were subjected to injury simulating ischemia by deprivation of oxygen and oxidizable substrates for periods ranging from 15 minutes to 10 hours. The extent of irreversible injury was determined by the percentage of lactic dehydrogenase (LDH) lost from the hearts to the culture medium during recovery from injury. Injury was essentially reversible at 1 hour of insult. The fraction of /sup 201/Tl content in injured compared with control hearts was not significantly lower after 1 hour of insult. By ...

1983-04-01

66

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

67

Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite  

Energy Technology Data Exchange (ETDEWEB)

The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, ...

2006-08-15

68

Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite  

International Nuclear Information System (INIS)

The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, ...

2005-07-24

69

The behavior of thermally and optically stimulated luminescence of SrAl2O4:Eu2+,Dy3+ long persistent phosphor after blue light illumination  

International Nuclear Information System (INIS)

The behavior of afterglow (AG), thermoluminescence (TL), infrared stimulated luminescence (IRSL) and phototransferred TL (PTTL) under thermal and/or infrared (IR) stimulation in blue (470 nm) light illuminated at room temperature (RT) SrAl2O4:Eu2+, Dy3+ is presented. The TL glow curve consists of four peaks with maxima at about 340, 430, 560 and 680 K. The 340 and 440 K peaks are described well by second order kinetics with activation energies of 0.83 and 1.05 eV, respectively. The AG decay is fitted by the Becquerel's law with exponent 1.5 and correlates well with the thermal emptying of the traps responsible for the 340 K peak. The 340 and 430 K TL peak traps are destroyed under IR (830 nm) stimulation creating IRSL. IR stimulation after illumination with blue light and preliminary heating restore partially the 340 and 430 K TL peaks by phototransfer from deeper traps. The shape ...

2008-02-01

70

Tumour affinity of [sup 203]Pb-chloride: comparison with [sup 67]Ga-citrate and [sup 201]Tl-chloride  

Energy Technology Data Exchange (ETDEWEB)

[sup 203]Pb-chloride is a promising imaging agent for tumour scanning because of the large retention value for tumour tissue and the small value for normal organs, but the large value for the kidneys and bone is a shortcoming. The retention value of [sup 203]Pb in tumour tissue is larger than that of [sup 201]Tl and smaller than that of [sup 67]Ga. The tumour/inflammatory lesion retention ratio for [sup 203]Pb is very large in comparison with those for [sup 67]Ga and [sup 201]Tl. [sup 203]Pb accumulates to a large extent in viable tumour tissue, and less in necrotic tumour tissue and in inflammatory lesion. (author).

1994-01-01

71

Thermoluminescence of irradiated RbCl and RbCl:Sn crystals  

International Nuclear Information System (INIS)

The thermoluminescence (TL) and emission of coloured RbCl and RbCl:Sn crystals are studied in the temperature range 300 to 560 K. The glow peaks responsible for F centres and tin centres in different valence states are identified using optical bleaching studies. The glow peaks are analysed using total curve fitting method and the kinetic parameters are determined. In moderately #gamma#-irradiated tin-doped RbCl crystals, the TL emission bands observed at 4.0, 3.6, and 2.2 eV are attributed to Sn"0, Sn"+, and Sn"- centers, respectively. A comprehensive energy level diagram depicting the various TL processes in these undoped and tin-doped RbCl crystals is proposed. (author).

72

Purification of cyclotron-produced "2"0"3Pb for labeling Herceptin  

International Nuclear Information System (INIS)

A simple and rapid procedure was developed for the purification of cyclotron-produced "2"0"3Pb via the "2"0"3Tl(d,2n) "2"0"3Pb reaction. A Pb(II) selective ion-exchange resin, with commercial name Pb Resin from Eichrom Technologies, Inc., was used to purify "2"0"3Pb from the cyclotron-irradiated Tl target with excellent recovery of the enriched Tl target material. The purified "2"0"3Pb was used to radiolabel the monoclonal antibody Herceptin. The in vitro and in vivo properties of the "2"0"3Pb radioimmunoconjugate were evaluated.

2005-04-01

73

Comparative study of infrared-stimulated luminescent and thermoluminescent dating of archaeological artefacts  

Energy Technology Data Exchange (ETDEWEB)

In this study, thermoluminescence (TL) dating of archaeological artefacts from Geboltskirchen (Upper Austria) and Haselbach (Lower Austria) has been carried out. To receive a comparison with TL dating, all samples have been investigated additionally by means of infrared-stimulated luminescence (IRSL) analysis. The samples were prepared according to the common fine-grain technique. All important dating parameters such as potassium concentration, thorium/uranium ratio, moisture content, etc. were determined. A methodology for IRSL was developed, describing all steps of the procedure from sample preparation to measurement for any kind of ceramic artefacts. Dating results from TL and IRSL investigations of ancient pottery from Geboltskirchen and Haselbach will be discussed.

2008-02-15

75

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

81

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

82

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

83

The use of calcium silicate bricks for retrospective dosimetry  

International Nuclear Information System (INIS)

The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples ...

2004-02-01

84

Nuclear data sheets update for A = 203  

Energy Technology Data Exchange (ETDEWEB)

Experimental results of nuclear reaction and radiative decay for A = 203 nuclides are evaluated. Adopted properties for all the nine isobars, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr of mass 203 are presented. Nothing is yet known for [sup 203]Os. 96 refs.

1993-09-01

85

Nuclear data sheets update for A = 203  

International Nuclear Information System (INIS)

Experimental results of nuclear reaction and radiative decay for A = 203 nuclides are evaluated. Adopted properties for all the nine isobars, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr of mass 203 are presented. Nothing is yet known for "2"0"3Os. 96 refs.

86

Additional Surveys of Natural Hot Springs in Nakorn Si Thammarat Province  

International Nuclear Information System (INIS)

Having know of four more natural hot spring located in Amphur Phipun, Nakorn Si Thammarat Province, the present investigators went on July 27, 2005 to collect water samples from the four new hot springs in Ampur Phipun, Nakorn Si Thammarat Province. The methods of collection and the determination of radon gas and free-living amoeba were the same as those employed in previous studies. The results revealed radon concentrations higher than the drinking safety limits of 11 Bq/L in specimens from Baan Huaysai Kow (32.30 Bq/L) and Baan Hunob (31.18 Bq/L; both naegleria and acanthamoeba were present in the specimens of the above two sites, whereas only naegleria recovered from Baan Huaysai Kow (Nai Nukul place) and none from Baan Nong Bua.

2005-12-01

87

Thermoluminescence emission of X-irradiated Eu{sup 2+} doped KBr single crystals  

Energy Technology Data Exchange (ETDEWEB)

In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with {approx} 50 ppm of Eu{sup 2+} ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at {approx} 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu{sup 2+} impurity acts as an electron trap during the irradiation process ...

1996-12-31

88

Thermoluminescence emission of X-irradiated Eu"2"+ doped KBr single crystals  

International Nuclear Information System (INIS)

In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with #approx# 50 ppm of Eu"2"+ ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at #approx# 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu"2"+ impurity acts as an electron trap during the irradiation process and that ...

89

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

90

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

91

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

92

Quantitative thallium-201 scintigraphy after dipyridamole infusion combined with low level exercise in healthy volunteers  

Energy Technology Data Exchange (ETDEWEB)

To establish test specific normal limits for quantitative analysis of uptake and washout of /sup 201/Tl after dipyridamole infusion combined with low level exercise, 20 healthy volunteers were studied with low likelihood of coronary artery disease (CAD) assessed by a stepwise probability analysis based on age, sex, symptoms, resting electrocardiogram, and exercise electrocardiography. Likelihood of CAD in these volunteers was calculated as less than or equal to 1%. After dipyridamole infusion combined with low level exercise, one volunteer complained of headache; no other side effects were observed. There were no chest pain complaints. Maximal hemodynamic changes were achieved during the 6th and 7th min of the test. No ST segment depression was recorded. Visual analysis of the /sup 201/Tl scintigrams was normal in all volunteers. Mean regional washout at 4 h was 44.37%+-2.11%. The regional washout in the 70/sup 0/ LAO view (46.65%+-1.10%) was ...

1989-05-01

93

A critical look at the kinetic models of thermoluminescence-II. Non-first order kinetics  

Energy Technology Data Exchange (ETDEWEB)

Non-first order (FO) kinetics models are of three types; second order (SO), general order (GO) and mixed order (MO). It is shown that all three of these have constraints in their energy level schemes and their applicable parameter values. In nature such restrictions are not expected to exist. The thermoluminescence (TL) glow peaks produced by these models shift their position and change their shape as the trap occupancies change. Such characteristics are very unlike those found in samples of real materials. In these models, in general, retrapping predominates over recombination. It is shown that the quasi-equilibrium (QE) assumption implied in the derivation of the TL equation of these models is quite valid, thus disproving earlier workers' conclusion that QE cannot be held under retrapping dominant conditions. However notwithstanding their validity, they suffer from the shortcomings as stated above and have certain lacunae. For ...

2005-01-07

94

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

95

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

96

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

97

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

98

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

99

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

100

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

101

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

102

Utilization of Tc-99m-TBI as a myocardial perfusion agent in exercise studies: Comparison with Tl-201 thallous chloride and examination of its biodistribution in humans  

Energy Technology Data Exchange (ETDEWEB)

Twenty-four patients were studied with both /sup 201/Tl-thallus chloride and /sup 99m/Tc-TBI scintigraphy following exercise. Comparison of the two agents in detecting segmental myocardial ischemia and scar was made in 18 patients with evidence of coronary artery disease on /sup 201/Tl-thallous chloride scintigraphy. Agreement between the two studies was observed in 77% (125 of 162) of left ventricular segments, suggesting that /sup 99m/Tc-TBI can be used as a myocardial perfusion agent. Limitations were related to early high background activity from lungs and liver. The high lung activity and early myocardial redistribution within the 1st hour contributed to the failure of /sup 99m/Tc-TBI to detect 16 segmental defects seen in the immediate post-exercise thallous chloride scan. Persistently high liver activity additionally affected accurate interpretation in the left ventricular segments close to the diaphragm. Improvement in the accuracy of ...

1986-10-01

103

Positron annihilation in high-T/sub c/ superconductors  

International Nuclear Information System (INIS)

We report ab initio calculations of positron wave functions in the high-T/sub c/ superconductors YBa_2Cu_3O_7, Bi_2Sr_2CaCu_2O_8, and Tl_2Ba_2CaCu_2O_8 using the general potential linearized augmented plane-wave method. The calculated positron wave functions are fairly insensitive to whether or not electron-positron correlation is included in the calculation for YBa_2Cu_3O_7 and Tl_2Ba_2CaCu_2O_8, but the calculated positron density is quite sensitive to correlation in Bi_2Sr_2CaCu_2O_8. While the positron wave function samples primarily the chain region in YBa_2Cu_3O_7, the results indicate that positrons should be good probes of the Cu-O layer-derived electronic states near the Fermi energy in Tl_2Ba_2CaCu_2O_8 since a large overlap with these states is predicted.

104

Optimization of isotope production by cross section determination  

International Nuclear Information System (INIS)

In order to optimize the production of "2"0"1Tl and "6"7Ga using the (p, xn) reactions on enriched "2"0"3Tl and "6"8Zn targets we established a new set of cross section curves for the most relevant reactions. Target stacks made of up to 15 thin (50 #mu#m) natural Tl or Zn foils interleaved with brass degradation foils were irradiated with incident proton energies from 42 to 10 MeV in overlapping experiments. Yields for "2"0"0","2"0"1","2"0"2"m","2"0"3","2"0"4"mPB and "6"6","6"7","6"8Ga were computed from measured #gamma# emission rates. Where possible, cross section curves for the nuclear reactions involved were computed. Thick target yields and contamination ratios for enriched targets were derived and show good agreement with results from actual production runs. (orig.).

105

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS  

International Nuclear Information System (INIS)

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an ...

2010-07-11

106

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

107

Separation of /sup 203/Pb by ion-exchange chromatography on Chelex 100 after production of /sup 203/Pb by the Pb(p,xn)/sup 203/Bi/sup EC. beta. +/ -> /sup 203/Pb nuclear reaction  

Energy Technology Data Exchange (ETDEWEB)

Bismuth radioisotopes, produced by 50-MeV proton bombardment of a lead target in a cyclotron, are separated from the lead target material by ion-exchange chromatography on a column containing 5.0 ml of Chelex 100. After a decay period of 24 hr, the /sup 203/Pb formed in situ is eluted from the column and then separated from /sup 200/Tl and /sup 201/Tl on a second ion-exchange column containing 0.5 ml of Chelex 100. Separations are sharp and carrier-free /sup 203/Pb is obtained.

1989-04-01

108

Nuclear magnetic resonance study of La_3X compounds and related phases  

International Nuclear Information System (INIS)

Normal state nuclear magnetic resonance studies of the La_3In, La_3Tl compounds have been made in order to investigate the origin of the large temperature-dependent magnetic susceptibility. It is possible to analyse the different contributions to the susceptibility using Knight-shift and relaxation time T_1 measurements of In"1"1"5 and Tl"2"0"5 nuclei. The exchange enhancement of the spin-susceptibility chisub(pd) is of the same order as that found in A-15 compounds and the strong temperature-dependence of chi(T) is attributed to the presence of a peak in the electronic density of states near the Fermi level. The variation of the Knight-shift in the ternary alloys La_3Xsub(1-y)Xsub(y)sup(') is analogous to that observed in the corresponding La_3X phases, on the other hand the Knight-shift in the carbides La_3XC is temperature independent. (author).

109

Cyclotron produced lead-203  

International Nuclear Information System (INIS)

The radioactive isotopes of lead are reviewed with respect to their choice for in vitro tracer studies. The #gamma#-photon energy and absence of particle emission in the decay of "2"0"3Pb makes it particularly suitable for these applications. Reaction yields of "2"0"3Pb using "2"0"3Tl targets and proton, deuteron, "3He and "4He beams are listed. Using the preferred reaction "2"0"3Tl (d, 2n)"2"0"3Pb with a 15 MeV deuteron beam, yields of about 75 #mu#Ci #mu#Ahr"-"1, after chemical separation, are reported. Details of target design and chemical separation are given. (U.K.).

110

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The ...

2003-03-04

111

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can avoid these demerits. This analysis method was applied to the ...

1996-10-01

112

Numerical analysis of natural convection in a square cavity at high Rayleigh numbers using the GSMAC finite-element method. GSMAC yugen yosoho ni yoru ko Rayleigh su seihokei cavity nai shizen tairyu no hi teijo kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Stable and accurate numerical analytical method even at high Rayleigh numbers is desired, and in addition flexibility and economical efficiency are very important for numerical analysis. Unsteady flows of natural convention in a square cavity are investigated using the GSMAC (generalized and simplified marker and cell) finite-element method at high Rayleigh numbers from 10 {sup 6} to 10 {sup 8}. Validities of the multi-pass algorithm and BTD (balancing tensor diffusivity), which are highly accurate solutions for finite-element method, are investigated by introducing them to the GSMAC finite-element method. As the result, it was found that the multi-pass algorithm has little effect for the GSMAC finite-element method. The steady solutions at the Rayleigh numbers of 10 {sup 5} and 10 {sup 7} agreed well with the bench mark solutions and numerical solutions. Complex transient phenomena at Rayleigh numbers higher than 10 {sup 7} are successfully observed. 12 refs., 11 figs., 4 tabs.

1990-10-25

113

Effect of water content on the activity of lipase-hydrolysis of olive oil in reverse micelles. Gyakuso micelle nai ni okeru lipase no olive oil kasui bunkai hanno no gansuiritsu izonsei  

Energy Technology Data Exchange (ETDEWEB)

Hydrolysis of olive oil by Chromobacterium viscosum lipase was studied in a reverse micellar system of a anionic surfactant Aerosol OT (AOT) and isooctane. Different methods of solubilization of the micellar system afford specific dependence of enzymatic activity of the lipase on the water content in the micelles. In an injection method, water content is controlled by the amount of injected water, which determines the micelle size and hydrophobicity of the micelle without salt addition and changes reversibly the conformation of lipase corresponding to the change of lipase activity. The activity reaches the maximum at a water content (water/AOT)of 7. In a phase transfer method, water content is determined by salt concentration in the aqueous phase in contact with micelles and the water content corresponding to the maximum activity is 12 to 13, below which the activity decrese drastically. Addition of taurodeoxycholic acid to the AOT micelles suppresses the reversible conformational ...

1992-01-10

114

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

115

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

116

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

121

Developments and tests of double-sided silicon strip detectors and read-out electronics for the Internal Tracking System of ALICE at LHC  

CERN Document Server

The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.

1999-01-01

122

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

123

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

124

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

125

Influence of Dopants on Characteristics of X-Ray Detectors Fabricated from Indium-, Gallium-, and Chlorine-Doped Cadmium Telluride Single Crystals  

Science.gov (United States)

Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.

1995-08-01

126

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this ...

2011-02-01

127

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

128

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

129

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

130

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

131

lla4892q.305  

Science.gov (United States)

PeDEL GRcXPmDtlSEZ`H==>T32\\ZtrPOP6tM UKwNEH5|J?:O TONRHwIN O1?)J`MiO\\ ?CQBYIL robb_M RSM7A8: qL6;90f44:7\\I07QO AE/U U_PbqIBYc6mTL?:2NDerX=Z =P<;K aRITGUN ...

132

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

133

Solution of Bohr's collective Hamiltonian for transitional odd-mass nuclei  

International Nuclear Information System (INIS)

A numerically feasible method, based on the use of deformed phonons, is developed for the diagonalization of the collective quadrupole Hamiltonian for a system with an odd particle coupled to an anharmonic even core. Examples: the transition from prolate to oblate via #gamma#-unstable shapes and furthermore the hsub(9/2) spectra of the nuclei "1"8"7Ir and "1"9"7Tl. (Auth.).

134

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

135

Optically stimulated luminescence (OSL) study of synthetic stishovite  

International Nuclear Information System (INIS)

Optically stimulated luminescence (OSL) of synthetic stishovite was investigated for a future dating technique of meteor impact craters. Luminescence around 330 nm was measured on the #gamma#-ray irradiated stishovite under two stimulating light sources of infrared laser (830 nm) and blue light emitting diode set (470 nm). Thermoluminescence (TL) studies before and after the OSL measurements showed the intensities around 100-200 deg. C and 220-350 deg. C to increase and those around 350-450 deg. C to decrease. This indicates that a part of deep-trapped charges excited during the OSL measurements were retrapped by shallower traps. The infrared stimulated luminescence (IRSL) after the TL measurement up to 450 deg. C could not be detected, while the blue light stimulated luminescence (BLSL) after TL had about one-tenth of the intensity before TL. This indicates that a part of the charges in shallower traps ...

2000-12-15

136

Large scale rooftop photovoltaics grid connected system at Charoenphol-Rama I green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a technical feasibility study project for the large scale rooftop photovoltaics (PV) grid connected system at Charoenphol-Rama I green building super store of TESCO LOTUS (TL) in Thailand. The objective of this project is (i) to study the technical feasibility of installation 350 kWp PV systems on the top of the roof in this site (ii) and to determine the energy produce from this system. The technical factors are examined using a computerized PVS 2000 simulation and assessment tool. This super store building located in Bangkok, with latitude 14 N, longitude 100 E and the building direction is 16 from North direction. The building roof area is 14,000 m2; with 3 degree face East and 3 degree face West pitch. Average daily solar energy in this area is approximately 5.0 kWh. The study team for this project consists of educational institution as School of Renewable Energy Technology (SERT) and private institution as Panya Consultants (PC). ...

2004-07-01

137

Alpha particle induced TL supralinearity in TLD-100: dependence on vector properties of the radiation field  

Energy Technology Data Exchange (ETDEWEB)

The linear/supralinear behaviour of the TL dose response in LiF:Mg,Ti (TLD-100) and its dependence on ionisation density is a fairly unique phenomenon which cannot be explained by conventional atomic 'conduction band/valence band' kinetic models. The Track Interaction Model (TIM) provides the microscopic framework which, when coupled with other appropriate physical mechanisms (spatial localisation of traps and recombination centres, competing centres, variations in the capture cross sections with temperature, etc.) can be used to describe all the dominant features of the TL supralinearity of LiF:Mg,Ti and similar TL systems. The unique feature of the TIM applied to alpha particles is that it is an integral approach with only one free parameter, the average charge carrier migration distance in the luminescence recombination stage. Although the TIM provides a comprehensive description of the mechanisms ...

1993-01-01

138

Quantum entanglement, recoherence and information flow in an accelerated detector - quantum field system: Implications for black hole information issue  

CERN Document Server

We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the detector never ...

2007-01-01

139

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

140

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

141

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...

1988-12-01

142

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

143

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

144

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is ...

1991-03-13

145

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

146

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

147

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

148

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

149

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

150

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

151

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

152

GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector  

Science.gov (United States)

We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon

2007-01-01

153

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

155

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

156

Advances in imaging THGEM-based detectors  

International Nuclear Information System (INIS)

We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.

2007-03-01

157

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

158

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

159

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

160

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

161

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

162

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

163

Fundamental understanding of aging processes Review of the workshop results  

CERN Document Server

A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.

2003-01-01

164

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

165

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

166

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

167

Yield and excitation function measurements of some nuclear reactions on natural thallium induced by protons leading to the production of medical radioisotopes {sup 201}Tl and {sup 203}Pb  

Energy Technology Data Exchange (ETDEWEB)

Excitation functions for {sup 201}Pb, {sup 202m}Pb, {sup 203}Pb and {sup 204m}Pb radionuclides which are formed via proton induced reactions with natural thallium target have been measured from their respective threshold (E{sub thr}) to 27.5 MeV using activation technique. Natural copper foils were used to monitor the cyclotron beam. The integral yields (MBq/{mu}A h) of the produced radionuclides were calculated from the measured excitation functions. The optimum proton energy range for the production of {sup 203}Pb with low amount of impurities is (16-10 MeV) after 5 h of EOB. The experimental cross-sections for {sup nat}Tl(p,xn) reactions were compared with the cross-sections recommended by the IAEA and with earlier published data when it was possible. (orig.)

2007-07-01

168

Usefulness of myocardial imaging by [sup 123]I-MIBG in assessment of diabetic neuropathy  

Energy Technology Data Exchange (ETDEWEB)

In diabetic patients with autonomic neuropathy, it is suggested that there is a reduced uptake of [sup 123]I-metaiodobenzylguanidine (MIBG) in the heart. We compared the difference of myocardial [sup 123]I-MIBG accumulation between 4 diabetic patients with triopathy and 6 patients without it. In all 10 patients, coronary angiography and [sup 201]Tl imaging (rest and 4 hours later) were performed. [sup 123]I-MIBG (111 MBq) was administered intravenously and its imaging was recorded on 15 minutes and 4 hours after injection. In all 4 cases with triopathy, [sup 123]I-MIBG imaging showed defect in apical and inferior region. In 2 out of 6 cases without triopathy, rapid clearance was noticed in apical and inferior region. There was no significant stenosis in right coronary artery and no defect in initial and delayed [sup 201]Tl images in all cases. We concluded that diabetic autonomic neuropathy in the heart was prominent in apical and inferior ...

1993-10-01

169

The response of some TL albedo neutron dosimeters  

International Nuclear Information System (INIS)

As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its response varies roughly as the cosine of the angle of incidence but is more complex at higher energies. (author).

170

Preliminary study of the application of natural olivine in Cenozoic dating  

Energy Technology Data Exchange (ETDEWEB)

The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL signal component ...

2006-08-15

171

NMR in highly correlated superconductors  

International Nuclear Information System (INIS)

Results of our systematic NMR study in high T_c cuprates are reviewed. The antiferromagnetic spin fluctuations (AFSF) decrease in the order of La_1_._8_5Sr_0_._1_5CuO_4. YBa_2Cu_3O_7 and Tl_2Ba_2CuO_6_+_y. 1/T_1 of "6"3Cu in the CuO_2 plane in the normal state follows essentially a Curie-Weiss law at high temperature and T_1T = const. law at low temperature. The temperature dependence of 1/T_1 and the Knight shift together with their impurity effect in the superconducting state strongly suggest d-wave pairing implying the AFSF to be responsible for the occurrence of superconductivity. From the NQR frequency measurement the density of Cu 3d and O 2p holes decreases and increases, respectively, in the order of La, Y and Tl compounds, which is consistent with the change of AFSF. The relation between T_c and #nu#_Q, and their pressure dependence suggest that there exists and optimum value of the ratio of Cu 3d and O 2p hole density to give a ...

1992-08-01

172

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...

2009-07-23

173

The production of carrier-free lead-203  

International Nuclear Information System (INIS)

The chemical separation of carrier-free "2"0"3Pb following deuterium bombardment of a "2"0"3Tl target is described. Coprecipitation from strontium sulphate was used to separate the "2"0"3Pb from a solution of the thallium target in sulphuric acid. The SrSO_4 precipitate was filtered, washed and dissolved in hydrochloric acid, from which "2"0"3Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given. (U.K.).

174

Shielded and unshielded geometries in the search for orphan sources  

Energy Technology Data Exchange (ETDEWEB)

A car-borne NaI(Tl) spectrometric system was used together with a {sup 137}Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-15

175

Shielded and unshielded geometries in the search for orphan sources  

International Nuclear Information System (INIS)

A car-borne NaI(Tl) spectrometric system was used together with a "1"3"7Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-01

176

Production of carrier-free lead-203  

Energy Technology Data Exchange (ETDEWEB)

The chemical separation of carrier-free /sup 203/Pb following deuterium bombardment of a /sup 203/Tl target is described. Coprecipitation from strontium sulphate was used to separate the /sup 203/Pb from a solution of the thallium target in sulphuric acid. The SrSO/sub 4/ precipitate was filtered, washed and dissolved in hydrochloric acid, from which /sup 203/Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given.

1982-07-01

177

Primary standardization of {sup 242} Am radioactive sources  

Energy Technology Data Exchange (ETDEWEB)

The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)

2001-07-01

178

Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92  

International Nuclear Information System (INIS)

The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.

1989-01-01

179

Modification of NPL-CRC secondary standards radionuclide calibrator holder to suit for IPEN vials  

International Nuclear Information System (INIS)

The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)

2000-10-05

180

A new method for the analysis of infrared stimulated luminescence data from potassium feldspars  

International Nuclear Information System (INIS)

A new method is described for the analysis of high precision pulse annealing data obtained using IRSL measurements on potassium feldspars using a Risoe reader. Presenting the data as the percentage of the signal lost per annealing phase permits more detailed comparisons to be made between samples. In addition, it is possible to directly compare the temperatures at which the TL and IRSL signals are released, thus giving information about the relationship between them. This method of analysis is applied to pulse annealing data for natural, irradiated, preheated and IR bleached aliquots. (author).

1993-07-01

181

[sup 123]I-MIBG myocardial scintigraphy in diabetic patients. Relationship with [sup 201]Tl uptake and cardiac autonomic function  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to investigate the influence of diabetic myocardial damage (suspected myocardial damage; SMD) diagnosed by [sup 201]Tl-SPECT and diabetic cardiac autonomic neuropathy (AN) on myocardial MIBG uptake in patients with NIDDM. Eighty-seven diabetic patients divided into four subgroups: 23 with SMD (+) AN (+); 19 with SMD (+) AN (-); 27 with SMD (-) AN (+); 18 with SMD (-) AN (-), and 10 controls were studied. Both planar and SPECT images were taken at 30 minutes (early) and 3 hours (delayed) after [sup 123]I-MIBG injection. The heart to mediastinum uptake ratio (H/M) and washout ratio of [sup 123]I-MIBG (WR) were obtained from both planar images. Similarly, the difference between the [sup 201]Tl image and the [sup 123]I-MIBG image in the total uptake score (TUS) was taken as the difference in the total uptake score ([Delta]TUS) representing cardiac sympathetic denervation without SMD. On both early and delayed planar ...

1998-12-01

182

Syntheses and crystal structures of the compounds In_3_._7Mo_1_5S_1_9, In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9 and ScTl_2Mo_1_5S_1_9 containing Mo_6 and Mo_9 clusters  

International Nuclear Information System (INIS)

The new compounds In_3_._7Mo_1_5S_1_9, In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9, and ScTl_2Mo_1_5S_1_9 have been synthesized by solid-state reaction in sealed molybdenum crucible at about 1250 deg. C. Their crystal structures were solved and refined from X-ray single-crystal data in the hexagonal space group P63/m. Their Mo-S framework consists of an equal mixture of Mo_6S_8S_6 and Mo_9S_1_1S_6 cluster units interconnected through Mo-S bonds. In In_3_._7Mo_1_5S_1_9, the In atoms occupy crystallographically different positions depending on their formal oxidation states of +1 or +3. This was confirmed by replacing partially or totally the monovalent indium by another monovalent cation such as the rubidium, cesium or thallium and the trivalent indium by the scandium to get the new In_1_._6Rb_2Mo_1_5S_1_9, In_2_._2CsMo_1_5S_1_9, and ScTl_2Mo_1_5S_1_9 compounds, respectively.

2004-11-30

183

Respiratory impairment due to asbestos exposure in brake-lining workers  

International Nuclear Information System (INIS)

There is extensive evidence that exposure to asbestos causes pulmonary parenchyma fibrosis, pleural disease, and malignant neoplasm in asbestos-exposed workers. However, few data concerning brake-lining workers are available in the literature. In this study, we aimed to assess the long-term effects of chrysotile asbestos exposure on lung function and the risk of asbestos-related diseases in brake-lining workers. Seventy-four asbestos-exposed workers who processed brake-lining products and 12 unexposed office workers were offered pulmonary function tests (spirometry and transfer actor) in 1992 and 1999. In 1999, the mean duration of asbestos exposure was 0.00#+-#4.07 and 11.02#+-#4.81 years (7-31 years) in non smoking and smoking asbestos workers, respectively. Transfer factor (T_L, CO) and transfer coefficient (K_C_O) decline were significant in the 7-year follow-up in both smoking and non smoking asbestos workers. However, lung function indices of he control ...

2003-03-01

184

Intrinsic Dosimetry Of Glass Containers Used To Transport Nuclear Materials: Potential Implications to the Field of Nuclear Forensics  

International Nuclear Information System (INIS)

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of ...

185

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

186

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

187

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

188

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

189

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

190

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

191

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

192

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

1991-09-01

193

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

194

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

195

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

196

Neutron detector counting capabilities for /sup 10/B-lined and /sup 235/U fission chambers in high gamma-ray fluxes  

Energy Technology Data Exchange (ETDEWEB)

This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...

1985-03-01

197

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

198

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

199

35 years of Thermoluminescence Dosimetry (TLD) in personnel and environmental monitoring in India - a tribute to Dr. K G Vohra  

International Nuclear Information System (INIS)

Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully ...

200

Purification and characterization of (-)(/sup 125/I)hydroxyphenylisopropyladenosine, an adenosine R-site agonist radioligand and theoretical analysis of mixed stereoisomer radioligand binding  

Energy Technology Data Exchange (ETDEWEB)

(-)-N6-(R-4-Hydroxyphenylisopropyl)adenosine (HPIA) was iodinated with NaI and trace /sup 125/I. Mono- and diiodinated reaction products and the starting material were separated by high pressure liquid chromatography and the structures of the reaction products were verified by NMR. (-)-N6-(R-Phenylisopropyl)adenosine (PIA), IHPIA, and I2HPIA decreased rat atrial contractility with ED50 values of 24, 28, and 33 nM, respectively. The contractile effects of these compounds were competitively blocked by theophylline (KI . 7.9 microM), but were not affected by adenosine deaminase. IHPIA also inhibited (-)isoproterenol-stimulated cyclic AMP accumulation in adipocytes with an ED50 (10 nM) and to an extent (83%) nearly identical to PIA. (/sup 125/I)HPIA prepared using carrier-free /sup 125/I bound to adenosine receptors on membranes from rat cerebral cortex, adipocyte ghosts, and heart ventricles. Binding was inhibited stereospecifically by PIA and by other adenosine ...

1984-11-01

201

Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector  

Energy Technology Data Exchange (ETDEWEB)

The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with ...

2006-07-01

202

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...

1997-02-01

203

Electronics for the Si detectors in APEX  

Energy Technology Data Exchange (ETDEWEB)

APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel Peak-to-FERA (PTF) ...

1994-07-01

204

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the ...

205

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties ...

2007-06-11

206

The hunt for ?13 at the Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.

2010-03-30

207

The cross-coupled interferometer for gravitational wave detection  

International Nuclear Information System (INIS)

The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.

2002-04-07

208

Tests with superconducting re-entrant cavities for transducer applications in gravitational wave detectors  

International Nuclear Information System (INIS)

We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.

2004-03-07

209

Sudbury neutrino detector  

International Nuclear Information System (INIS)

The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.

210

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

211

Silicon Detector Letter of Intent  

Energy Technology Data Exchange (ETDEWEB)

This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.

2010-05-26

212

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

213

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

214

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

215

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

216

A PDA-Based ECG Beat Detector for Home Cardiac Care.  

Science.gov (United States)

Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192

2005-01-01

217

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

218

The mass dependence of the signal peak height of a Bragg-curve ionization chamber  

International Nuclear Information System (INIS)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).

219

The CDF intermediate silicon layers detector  

Energy Technology Data Exchange (ETDEWEB)

The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.

1999-11-01

220

The Brazilian Bragg curve detector built for AMS studies  

Energy Technology Data Exchange (ETDEWEB)

A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.

2000-10-01

221

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

222

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...

2001-01-01

223

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

224

Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information  

International Nuclear Information System (INIS)

The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)

2010-11-01

225

Radon concentration measurements by means of nuclear tracks detector with image analysis  

International Nuclear Information System (INIS)

English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,

1998-09-15

226

Photoconductive ultraviolet detectors based on ZnO films  

British Library Electronic Table of Contents (United Kingdom)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...

2006-01-01

227

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

228

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...

2006-10-29

229

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

230

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

231

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through ...

1992-01-01

232

Mass dependence of the signal peak height of a Bragg-curve ionization chamber  

Energy Technology Data Exchange (ETDEWEB)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.

1985-01-01

233

Linewidth-broadened Fabry-Perot cavities within future gravitational wave detectors  

International Nuclear Information System (INIS)

The bandwidth of LIGO-like terrestrial interferometric gravitational wave detectors is set by the pole of the Fabry-Perot cavities within the arms of the Michelson interferometer. This constraint arises because the gain of gravitational wave-induced signal sidebands is limited to frequencies within the linewidth of the cavities. The nature of standard Fabry-Perot cavities is such that one cannot independently adjust for increased gain without suffering a loss of bandwidth. If these quantities could be decoupled, the resulting improvement in bandwidth may lead to viable high frequency detectors. A pair of anti-parallel diffraction gratings within a Fabry-Perot cavity can increase the bandwidth of a LIGO-scale detector by a factor of #approx#1000.

2004-03-07

234

LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA  

Science.gov (United States)

Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...

235

Intercomparison of Retrospective Radon Detectors  

Energy Technology Data Exchange (ETDEWEB)

We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two ...

1998-11-01

236

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in ...

2006-11-13

237

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

238

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-15

239

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-01

240

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

241

DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA  

Science.gov (United States)

FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...

242

Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid  

CERN Document Server

In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.

1993-01-01

243

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

Energy Technology Data Exchange (ETDEWEB)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

1993-12-31

244

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

International Nuclear Information System (INIS)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

247

Annihilation of antiprotons in light nuclei  

CERN Document Server

CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.

2006-01-01

248

AeroSpace Information for a Changing World - NASA Technical ...  

Science.gov (United States)

Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...

249
250

A Quantum-Enhanced Prototype Gravitational-Wave Detector  

CERN Document Server

The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by ...

2008-01-01

251

8 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

feature similar to the face detection in Intel's OpenCV library, implement it in Matlab code, and test the performance of the new ROI detector against the ...

252

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating from room temperature (RT) up to 500 deg. ...

2009-04-15

253

In vitro evaluation of herpes simplex virus type 1 thymidine kinase reporter system in dynamic studies of transcriptional gene regulation  

Energy Technology Data Exchange (ETDEWEB)

The herpes simplex virus type 1 thymidine kinase (HSV1-TK) reporter system is being used to directly and indirectly monitor therapeutic gene expression, immune cell trafficking and protein-protein interactions in various living animals. However, the issues of HSV1-TK enzyme stability in living cells and whether this reporter system is optimal for dynamic studies of gene expression events in genetic imaging have not be addressed. The purpose of the present study was to evaluate the application of this reporter system in dynamic studies of transcriptional gene regulation. To achieve this purpose, we established two tetracycline-inducible murine sarcoma cell lines, tetracycline-turn-off HSV1-tk-expressing cell line (NG4TL4/tet-off-HSV1-tk) and tetracycline-turn-off Luc-expressing cell line (NG4TL4/tet-off-Luc), to create an artificially regulated gene expression model in vitro. The dynamic transcriptional events mediating a series of doxycycline ...

2006-07-15

254

Ultratrace determination in high purity molybdenum and tungsten with ion chromatographic trace-matrix-separation. Pt. 2; Ultra trace analysis using ion chromatography. Ultraspurenanalytik in hochreinem Molybdaen und Wolfram mit ionenchromatographischer Spuren-Matrix-Trennung. Tl. 2; Ionenchromatographische Ultraspurenanalyse  

Energy Technology Data Exchange (ETDEWEB)

The use of high-performance ion exchangers allows a trace-matrix-separation (SMT) directly followed by an ion chromatographic (IC) separation of the analytes. Based on the principles described in Part 1, a combined procedure IC-SMT-IC for metallic impurities in Mo and W is presented. Up to 12 metal traces (Fe, Cu, Pb, Zn, Ni, Co, Cd, Ca, Mn, Sr, Mg and Ba) can be determined in one run with 35 min. A special method for traces of U and Th is also given. Detection limits are typically 10-100 ng g{sup -1} in the metal sample. (author). 14 refs.; 10 figs.; 6 tabs.

1992-01-31

255

The effect of trace elements on the fatigue behaviour of a carbide-hardened Fe-Ni-Cr alloy. Der Effekt von Spurenelementen auf das Zeitstandverhalten einer karbidverfestigten Fe-Ni-Cr-Legierung  

Energy Technology Data Exchange (ETDEWEB)

Fatigue tests were accomplished with a series of specimens doped with trace elements of a hardened Fe-Ni-Cr alloy, cast and hardened with intermetallic phases for determining the influence of these elements on the high temperature strength properties. The results of extensive fatigue tests show that even small contents of Te, Bi, Se, Pb, Tl and Zn considerably influence the life and creep processes especially after longer running periods, when added individually or combinedly. In contrast to this, the fatigue ductility is reduced by trace element additions even with short running periods. The order in which the metallic trace elements influence the fatigue properties nearly correlates with earlier work concerning Ni- and Co-superalloys. (orig.)

1993-01-01

256

Spectroscopy of {sup 25}Al and {sup 26,27,28}P using high-energy stripping reactions  

Science.gov (United States)

We report here results of an application of single-nucleon stripping reactions at high energies (65 MeV/u) in inverse kinematics to obtain spectroscopic factors. From measurements of the partial cross-sections for ground and excited states in residual nuclei formed in one-proton stripping reactions, single particle orbits and occupancies of light nuclei have been studied in the s-d shell. Single proton stripping cross-sections of {sup 25}Al and {sup 26,27,28}P on a Be target have been measured using the S800 spectrograph and the NaI(Tl) array at the NSCL. These results indicate that this technique may provide a general tool for the intermediate energy range analogous to transfer (pick-up) reactions at low-energy.

1998-12-21

257

Spectroscopy of "2"5Al and "2"6","2"7","2"8P using high-energy stripping reactions  

International Nuclear Information System (INIS)

We report here results of an application of single-nucleon stripping reactions at high energies (65 MeV/u) in inverse kinematics to obtain spectroscopic factors. From measurements of the partial cross-sections for ground and excited states in residual nuclei formed in one-proton stripping reactions, single particle orbits and occupancies of light nuclei have been studied in the s-d shell. Single proton stripping cross-sections of "2"5Al and "2"6","2"7","2"8P on a Be target have been measured using the S800 spectrograph and the NaI(Tl) array at the NSCL. These results indicate that this technique may provide a general tool for the intermediate energy range analogous to transfer (pick-up) reactions at low-energy.

1998-12-21

258

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

259

Practical superconductor development for electrical power applications  

Energy Technology Data Exchange (ETDEWEB)

Development of useful high-critical-temperature (high-{Tc}) superconductors requires synthesis of superconducting compounds; fabrication of wires, tapes, and films from these compounds; production of composite structures that incorporate stabilizers or insulators; and design and testing of efficient components. This report describes technical progress of research and development efforts aimed at producing superconducting components based on the Y-Ba-Cu, Bi-Sr-Ca-Cu, Bi-Pb-Sr-Ca-Cu, and Tl-Ba-Ca-Cu oxides systems. Topics discussed are synthesis and heat treatment of high-{Tc} superconductors, formation of monolithic and composite wires and tapes, superconductor/metal connectors, characterization of structures and superconducting and mechanical properties, and fabrication and properties of thin films. Collaborations with industry and academia are also documented. 10 figs.

1991-10-01

260

Luminescence dating  

International Nuclear Information System (INIS)

The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure to heat or to light. (author). 10 refs., 3 figs.

261

Image diagnosis of parathyroid glands in chronic renal failure  

Energy Technology Data Exchange (ETDEWEB)

Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.

1983-07-01

262

Frequency mixing crystal  

Energy Technology Data Exchange (ETDEWEB)

In a laser system for converting infrared laser light waves to visible light comprising a source of infrared laser light waves and means of harmoic generation associated therewith for production of light waves at integral multiples of the frequency of the original wave, the improvement of said means of harmonic generation comprising a crystal having the chemical formula X.sub.2 Y(NO.sub.3).sub.5 .multidot.2 nZ.sub.2 o wherein X is selected from the group consisting of Li, Na, K, Rb, Cs, and Tl; Y is selected from the group consisting of Sc, Y, La, Ce, Nd, Pr, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Al, Ga, and In; Z is selected from the group consisting of H and D; and n ranges from 0 to 4.

1992-01-01

263

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

264

Si(111)/Gd: A fast and high-resolution thermal neutron detector  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.

1998-07-01

265

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

266

Research in experimental elementary particle physics. A proposal to the U.S. Department of Energy  

Energy Technology Data Exchange (ETDEWEB)

We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.

1995-04-13

267

Radon concentration measurements in the soil  

International Nuclear Information System (INIS)

Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)

268

Proposed high-resolution vertex detector using superconductive thin strips  

Energy Technology Data Exchange (ETDEWEB)

The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alpha particle.

1984-06-01

269

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

270

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

271

Performance of the transition radiation detector in D{Phi}  

Energy Technology Data Exchange (ETDEWEB)

The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.

1994-12-31

272

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

273

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

274

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

275

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

276

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

277

Medical explorations by radioisotopes in Lebanon  

International Nuclear Information System (INIS)

This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.

278

Interaction region layout of the VLEPP based photon linear collider with ultimate luminosity  

Energy Technology Data Exchange (ETDEWEB)

In the present paper, a possible interaction region layout of the VLEPP based Photon Linear Collider (PLC) with ultimate luminosity is discussed. In order to remove spent electron beams, the crab-crossing scheme is used. The detector is protected from produced pairs and secondary particles by means of the detector magnetic field and a shielding mask. ((orig.)).

1995-02-01

279

Gamma ray detecting device using dislocation-free crystal  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.

1991-04-30

280

GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

281

First tests of "bulk" MICROMEGAS with resistive cathode mesh  

CERN Document Server

We present the first results from tests of a MICROMEGAS detector manufactured using the so-called "bulk" technology and having a resistive cathode mesh instead of the conventional metallic one. This detector operates as usual MICROMEGAS, but in the case of sparks, which may appear at high gas gains, the resistive mesh reduces their current and makes the sparks harmless. This approach could be complementary to the ongoing efforts of various groups to develop spark-protected MICROMEGAS with resistive anode planes.

2010-01-01

282

Explosives detection: the problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.

1984-01-01

283

Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector  

International Nuclear Information System (INIS)

The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).

1993-12-02

284

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

285

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

286

Determination of reactor kinetic parameters in a two-core reactor  

Energy Technology Data Exchange (ETDEWEB)

The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.

1982-01-01

287

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

288

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

289

Detection device for high explosives  

Energy Technology Data Exchange (ETDEWEB)

A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

1992-01-01

290

Ceramic inspection system  

Science.gov (United States)

A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.

2006-05-16

291

CPA simulator: A software tool to simulate nuclear front-end circuit response  

International Nuclear Information System (INIS)

A computer program 'CPA simulator' has been designed to simulate the response parameters of a typical charge preamplifier (CPA) used in nuclear front-end electronics. The response parameters are studied considering three common connection methods between the detector and the CPA. The simulator predicts and illustrates the role and influence of the different components of the CPA and detector circuits.

2010-12-21

292

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and ...

1984-06-05

293

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

294

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side ...

2005-11-23

295

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

296

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...

1995-11-01

297

A solution for solid state detector and preamplifier protection, during HV application and removal transition periods  

International Nuclear Information System (INIS)

Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).

298

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

299

Luminescent unit computerization to research spectral characteristics of fine film alkali halide crystal  

International Nuclear Information System (INIS)

The fundamental optical absorption of ion crystals characterizes the creation of different free low energetic electronic excitation (the excitons and electron-hole pairs), but their straight registration is not possible because of incommensurable big absorption factor of alkali halide monocrystals. So to registration the spectrums of alkali halide monocrystal very fine layers are necessary. We have received fine films of Nal and KCl in system of KCl-Nal-KCl, KCl-KI-KCl on the base of universal vacuum post VUP-4, VUP-5 by thermal evaporation. A unique spectral unit has been created For this on the basic the SDL-2 complex. Complex consists of radiator, systems of condensers, monochromators MDR-12 and MDR-23, receivers of radiation, controller by unit. Connect and control of monochromators by means of IBM-compatible computer has been created. Kinematics schemes of monochromators provide consequent removing on output slot of monochromatic radiation in operating range of each diffraction ...

300

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

301

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these ...

2001-01-01

302

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended ...

2004-12-21

303

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an ...

2002-01-01

304

Design and implementation of the BESIII detector-control system  

Energy Technology Data Exchange (ETDEWEB)

In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has ...

2008-07-21

305

Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama. Wilsonville ACL R and D Facility material balance procedure. Topical Report No. 11  

Science.gov (United States)

Prior to 1978, the Wilsonville Advanced Coal Liquefaction facility material balance surrounded only the thermal liquefaction unit and involved analyses of only the slurry stream and individual gas streams. The distillate solvent yield was determined by difference. Subsequently, several modifications and additional process units were introduced to this single unit system. With the inclusion of the deashing unit in 1978 and the catalytic hydrogenation unit in 1981, the process has evolved into a sophisticated two-stage coal liquefaction process and has the potential for various modes of integration. This report presents an elemental balancing procedure and a simplified presentation format that is sufficiently flexible to meet current and future needs. The development of the elemental balancing technique and the relevant computer programs to handle the calculations have been addressed. This will be useful in modelling individual unit performance as well as determining the impact of each ...

1984-09-01

306

Thallium-technetium subtraction parathyroid imaging in patients having previous parathyroid surgery  

International Nuclear Information System (INIS)

Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck exploration, all had PT pathology accurately localized by preoperative scanning (7=single adenoma, 2=single hyperplastic gland, 1=two hyperplastic ...

1985-06-02

307

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear relationship exists between ...

1985-06-02

308

Phosphor plasters of CaSO{sub 4}:Dy on the courtyard wall of Djehuty's tomb (Luxor, Egypt)  

Energy Technology Data Exchange (ETDEWEB)

The X-ray diffraction (XRD) and environmental scanning electron microscopy (ESEM) analyses of plasters collected from the courtyard walls of Djehuty's tomb show anhydrite, calcite, dolomite, quartz, alkali feldspars and accessorial amounts of halite and illite. The external outer bed is mainly composed by anhydrite, since the original hydrous phases of gypsum plaster were desiccated during thirty centuries in the dry land environment of the Luxor area, under low relative humidity and high temperatures. The luminescence analyses by thermoluminescence (TL) and cathodoluminescence (CL) demonstrate as one plaster sample (m8), i.e., 95% anhydrite, displays a gigantic TL emission of 33 555 a.u. and a SEM/CL emission of 2319 a.u. maxima peak. The spectra CL also exhibits a 484 nm peak attributable to the classic {sup 4}F{sub 9/2}{yields}{sup 6}H{sub 15/2} transition circa 490 nm of Dy{sup 3+} and a 573 nm emission of Dy{sup 3+} masked in a ...

2008-02-15

309

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for ...

1997-05-01

310

A large surface neutron and photon detector for civil security applications  

Energy Technology Data Exchange (ETDEWEB)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...

2010-05-21

311

A large surface neutron and photon detector for civil security applications  

International Nuclear Information System (INIS)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...

2010-05-11

312

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

313

Ultraviolet detectors based on ZnO films by thermal oxidation of Zn metallic films  

British Library Electronic Table of Contents (United Kingdom)

Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.

2008-01-01

314

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

315

Status of combined point source search with neutrino telescopes IceCube and AMANDA  

Energy Technology Data Exchange (ETDEWEB)

In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.

2010-07-01

316

Spatial distribution of IGC-30 Ge-detector's efficiency  

International Nuclear Information System (INIS)

The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).

1993-12-02

317

Some considerations about future interferometric GW detectors  

International Nuclear Information System (INIS)

The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.

2004-03-07

318

Quartz fiber calorimetry and calorimeters  

CERN Document Server

Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.

2004-01-01

319

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

320

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

321

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.

322

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

323

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for ...

1995-12-31

324

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

325

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

326

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

327

Indoor and outdoor Radon concentration measurements in Sivas, Turkey, in comparison with geological setting  

British Library Electronic Table of Contents (United Kingdom)

Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected h...

2010-01-01

328

High Energy Neutrino Telescopes  

CERN Document Server

This paper presents a review of the history, motivation and current status of high energy neutrino telescopes. Many years after these detectors were first conceived, the operation of kilometer-cubed scale detectors is finally on the horizon at both the South Pole and in the Mediterranean Sea. These new detectors will perhaps provide us the first view of high energy astrophysical objects with a new messenger particle and provide us with our first real glimpse of the distant universe at energies above those accessible by gamma-ray instruments. Some of the topics that can be addressed by these new instruments include the origin of cosmic rays, the nature of dark matter, and the mechanisms at work in high energy astrophysical objects such as gamma-ray bursts, active galactic nuclei, pulsar wind nebula and supernova remnants.

2008-01-01

329

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

330

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).

1983-08-26

331

Aging measurements of a TMAE-based photon detector for the HERA-B RICH  

CERN Document Server

We report on aging measurements of a photon detector candidate for the HERA-B RICH. The prototype, a proportional wire chamber operated with TMAE, was mounted on an argon filled test-beam RICH and was aged by UV light at rates we expect in HERA-B. We monitored gain and current continuously, and checked the chamber with Cherenkov photons at regular intervals. The number of detected photons/track (projected to 2.75 m C sub 4 F sub 1 sub 0 in HERA-B) dropped from 26 to 11 after two days of aging - well below the 20 required for pi/K separation. Based on these results, HERA-B decided to use multi-anode PMTs as photon detectors in the RICH.

1999-01-01

332

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

333

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

334

Using Military Working Dog Teams (MWDTs) to Support Law ...  

Science.gov (United States)

... 4. Military Working Dogs iMWDs). As used in this Instruction refers to drug detector dogs only. 5. Military Working Doq Executive Agent M(WJDEMA. ...

1990-09-17

335

Use of solid state nuclear track detectors for radon concentration measurements indoors  

International Nuclear Information System (INIS)

An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.

336

The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy  

UK PubMed Central (United Kingdom)

BackgroundMany studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for...Full Text Available

337

The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the ...

2009-01-01

338

The Development of a Neutral Particle Detector for Observations of the Thermosphere  

Science.gov (United States)

One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight ...

2006-12-01

339

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

340

Search for free quarks at PEP  

Energy Technology Data Exchange (ETDEWEB)

The results of a search for fractionally charged particles produced in e/sup +/e/sup -/ annihilation at 29 GeV/c/sup 2/ are discussed. Results from cosmic-ray searches for fractionally charged particles, tachyons, and massive particles using the same detector are also presented.

1982-01-01

341

Research in heavy-ion nuclear physics  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.

1992-01-01

342

Radon concentration measurement in dwellings in Belgrade  

International Nuclear Information System (INIS)

The results of the radon concentration measurements in dwellings in Belgrade were shown in this paper. The measurements were done using long term method with diffusion cups equipped with solid state nuclear track detector LR-115-II or CR-39. (author).

343

Post-column reaction detector for platinum(II) antieoplastic agents  

Energy Technology Data Exchange (ETDEWEB)

The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid chromatography (HPLC) ...

1984-03-01

344

Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies  

International Nuclear Information System (INIS)

A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.

345

Photoconductive ultraviolet detectors based on ZnO films  

Energy Technology Data Exchange (ETDEWEB)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant {tau} obtained from the curve fitting represents the ...

2006-12-15

346

Photoconductive ultraviolet detectors based on ZnO films  

International Nuclear Information System (INIS)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant #tau# obtained from the curve fitting represents the ...

2006-12-15

347

Photoconducting properties of ultraviolet detectors based on GaN and Al{sub 1{minus}x}Ga{sub x}N films grown by ECR-MBE  

Energy Technology Data Exchange (ETDEWEB)

GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.

1997-12-31

348

Photoconducting properties of ultraviolet detectors based on GaN and Al_1_-_xGa_xN films grown by ECR-MBE  

International Nuclear Information System (INIS)

GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.

1996-12-02

349

Performance assessment for EEG-based neonatal seizure detectors  

UK PubMed Central (United Kingdom)

ObjectiveThis study discusses an appropriate framework to measure system performance for the task of neonatal seizure detection using EEG. The framework is used to present an extended...Full Text Available

2011-03-01

350

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the ...

1999-07-01

351

Online processing in the ALICE DAQ The detector algorithms  

CERN Document Server

ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...

2010-01-01

352

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

Energy Technology Data Exchange (ETDEWEB)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

1983-01-01

353

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

International Nuclear Information System (INIS)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

354

Novel remote sensing gas outburst detector  

Energy Technology Data Exchange (ETDEWEB)

The possibility has been explored of using a laser scattering technique to detect the imminent onset of rock activity associated with gas outbursts. The instrument described in this paper provides a sensitive, remote and rapid means of passively monitoring micro-seismic activity at the exposed face.

1984-08-01

355

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

356

Midwave infrared type-II InAs/GaSb superlattice detectors with mixed interfaces  

Science.gov (United States)

We report the growth and fabrication of midwave infrared InAs/GaSb strain layer superlattice (SLS) detectors. Growth of alternate interfaces leads to a reduced strain between the GaSb buffer and SLS ({delta}a{sub parallel}/a=-5x10{sup -4}), enabling the growth of active regions up to 3 {mu}m (625 periods). The structural, optical, and electrical properties of the active region were characterized using x-ray crystallography and photoluminescence, respectively. p-i-n detectors were grown using 625 periods of 8 ML (monolayer) InAs/8 ML GaSb as the active region. The {lambda}{sub cutoff} for the detectors was 4.6 {mu}m with a conversion efficiency of 32% at V{sub b}=-0.2 V. Detectivity was obtained using noise power spectral density measurements under 300 K 2{pi} field of view illumination and was equal to 5.2x10{sup 10} and 3x10{sup 10} cm Hz{sup 1/2}/W (V{sub b}=-0.02 V, T=80 K) in the white noise and 1/f noise limit (at 50 ...

2006-07-01

357

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation ...

2007-08-21

358

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.

2001-05-01

359

MAGIC - Multi Anode Gas Ionization Chamber  

Energy Technology Data Exchange (ETDEWEB)

A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))

1994-12-01

360

Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences  

Science.gov (United States)

The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)

1973-08-01

361

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; ...

1982-12-01

362

Indoor radon concentration measurements by using SSNTD  

International Nuclear Information System (INIS)

In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.

363

Indoor radon concentration measurements  

International Nuclear Information System (INIS)

Some results of the indoor radon measurements are presented in this paper. Kodac track detectors LR-115 were used for these measurements. Average winter/spring ratio for indoor radon concentration was determined from the results obtained and is presented in this paper. (author).

364

Front-End-Electronics Communication software for multiple detectors in the ALICE experiment  

Energy Technology Data Exchange (ETDEWEB)

In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps ...

2006-02-15

365

Forschungszentrum Juelich, Institut fuer Kernphysik/COSY. Annual report 2004  

Energy Technology Data Exchange (ETDEWEB)

The following topics are dealt with: Detectors at COSY, major physics results at COSY, physics at external facilities, theoretical investigations, COSY operation and developments, preparations for FAIR, technical developments. (HSI)

2005-03-01

366

Feynmann variance-to-mean method  

Energy Technology Data Exchange (ETDEWEB)

The Feynmann and other fluctuation techniques have been shown to be useful for determining the multiplication of subcritical systems. The moments of the counting distribution from neutron detectors is analyzed to yield the multiplication value. We present the methodology and some selected applications and results and comparisons with Monte Carlo calculations.

1985-01-01

367

Explosives detection The problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

Explosives molecules have a number of unique properties. These properties are discussed. They include low vapor pressures, electronegativity, ''stickiness,'' frangibility, and thermal instability. The program for developing an advanced explosives detector is described.

1984-07-01

368

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

369

Does DaYa-Bay Reactor Play an Important Role in Theta_{13} of Lepton Mixing (PMNS) Matrix ?  

CERN Document Server

Reactor neutrinos play an important role in determining parameter theta_{13} in the lepton mixing (PMNS) matrix. Next important step on measuring PMNS matrix could be to build another reactor neutrino experiment in DaYa bay, China, to search the possible oscillations via sin^2 (2theta_{13}) and Delta m^2_{13}. We consider 4 different schemes for positions of three 8-ton detectors of this experiment, and simulate the results with respect to an array of assumed ''true'' values of physics parameters. Using three kinds of analysis method, we suggest a best scheme for DaYa-Bay which is to place a detector 2200m ~ 2500m symmetrically away from two reactors, and to put the other two detectors closer to their corresponding reactors respectively, almost at a 100m \\~ 200m distance. Moreover, with conservative assumption on the experimental technique, we construct series of allowed regions from our simulation results, and give ...

2004-01-01

370

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

371

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

372

Daya Bay Neutrino Experiment  

CERN Document Server

The Daya Bay Neutrino Experiment is proposed to measure sin^2(2\\theta_{13}) to better than 0.01 at 90% C.L. in a three-year run. The experimental site, detector design, and background estimation are presented.

2006-01-01

373

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The ...

1992-03-16

374

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to ...

2009-06-07

375

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed boron-lined ...

2009-11-02

376

Black holes as detectors of tachyons  

International Nuclear Information System (INIS)

Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).

377

Angular sensitivity distribution of detectors for BNCT  

Energy Technology Data Exchange (ETDEWEB)

The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction dependence of the detector by using the neutron radiography ...

1995-03-01

378

Symbol Error Rates of Maximum-Likelihood Detector: Convex/Concave Behavior and Applications  

CERN Document Server

Convexity/concavity properties of symbol error rates (SER) of the maximum likelihood detector operating in the AWGN channel (non-fading and fading) are studied. Generic conditions are identified under which the SER is a convex/concave function of the SNR. Universal bounds for the SER 1st and 2nd derivatives are obtained, which hold for arbitrary constellations and are tight for some of them. Applications of the results are discussed, which include optimum power allocation in spatial multiplexing systems, optimum power/time sharing to decrease or increase (jamming problem) error rate, and implication for fading channels.

2007-01-01

379

Response of track-etch dosemeters to environmental radon  

Energy Technology Data Exchange (ETDEWEB)

The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).

1988-01-01

380

Real time neutron dosemeter response calculations  

International Nuclear Information System (INIS)

The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).

1996-04-01

381

Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia  

Energy Technology Data Exchange (ETDEWEB)

Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The ...

2006-07-01

382

Proceedings of the technical exchange meeting on passive radon monnitoring  

International Nuclear Information System (INIS)

The purpose of the meeting was to bring together a number of scientists active in the development and use of passive radon monitoring instrumentation, primarily activated charcoal detectors and alpha track detectors. Many of those present expressed a desire to receive copies of the viewgraphs and other materials presented. Most have supplied extended abstracts or complete reports. These materials are reproduced here as a Technical Measurements Center Report for the benefit of those attending the meeting and for others interested in passive radon monitoring. Individual papers were processed separately for the data base.

1987-09-21

383

Positron-Electron Pair Creation Near Threshold  

Science.gov (United States)

Positron-electron pair creation near the threshold energy is extremely difficult to investigate by both experiments and theory. First test experiments were performed at the ILL to determine the cross sections for positron-electron pair creation near threshold using prompt {gamma}-rays from different targets after neutron capture and conventional radioactive sources. Pair creation was studied in a Ge detector, which simultaneously acted as sample and detector. First results are presented which show a significant deviation from theoretical values near threshold.

2009-01-28

384

Performance of the transition radiation detector flown on the NMSU/WIZARD TS93 balloon-borne instrument  

Energy Technology Data Exchange (ETDEWEB)

It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.

1995-09-01

385

Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)  

Energy Technology Data Exchange (ETDEWEB)

Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).

1993-01-01

386

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

387

Measurement of the inclusive Z production cross section with the CMS detector  

CERN Document Server

First measurements of inclusive Z production cross sections in muon and electron decay channels at 7 TeV are presented for proton-proton collisions in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The comparison of the kinematic quantities as well as the studies of selection efficiencies demonstrate a good agreement between simulated events and current data. The measured inclusive cross section for Z($\\gamma^{*}$) production agrees with NNLO QCD cross section calculations and current parton distribution functions.

2010-01-01

388

Forward Physics with the CMS experiment at the Large Hadron Collider  

CERN Document Server

multi-parton interactions and underlying event structure, $\\gamma$-mediated processes and luminosity determination, Monte Carlo tuning and even MSSM Higgs discovery in central exclusive production. In this article, the forward detector instrumentation around the CMS interaction point is described and the prospects for diffractive and forward physics using the CMS forward detectors are summarized. In addition, first observation of forward jets as well as early measurements of the forward energy flow in the pseudorapidity range $3.15

2010-01-01

389

Daya Bay reactor anti-neutrino experiment  

International Nuclear Information System (INIS)

The Daya Bay Reactor Anti-Neutrino Experiment is a neutrino oscillation experiment designed to observe and measure the neutrino mixing angle ?13. The sensitivity goal is 0.01 in sin 22?13 at the 90% confidence level, a significant improvement over the current limit. This will be accomplished by measuring the relative rates and energy spectra of reactor electron antineutrinos with multiple detectors positioned at different baselines. Civil construction is currently under-way as detector designs and planning near completion. Commissioning activities should be completed by the end of 2010, followed by a three-year run.

2008-11-01

390

Daya Bay Neutrino Experiment: Goal, Progress and Schedule  

CERN Document Server

Daya Bay Neutrino Experiment is dedicated to measuring the last unobserved neutrino mixing angle theta_13. The predicted precision on sin^2(2theta_13) is 0.01 at 90% confidence level. This document briefly reviews the measurement method and detector construction status. The first two anti-neutrino detectors' dry run result is also discussed. The Daya Bay near hall data taking is expected to commence in the summer of 2011 and the data taking of all of the three halls in the summer of 2012.

2011-01-01

391

Conceptual design of the ATLAS EM muon chamber support structures  

CERN Document Server

The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.

1998-01-01

392

Circuit design of PMT readout module for detector prototype of Daya Bay reactor neutrino experiment  

International Nuclear Information System (INIS)

This paper describes the design of PMT readout module for detector prototype of Daya Bay Reactor Neutrino Experiment. According to the design requirements of the readout module, the basic structure of the readout module is discussed. This paper also discusses how to realize the charge measurement and time measurement and data processing using a high performance FPGA. The DAQ system including three readout modules and one trigger module are well commissioned and doing data taking now. (authors)

2006-10-21

393

Application of proportional counters in Polish medicine and agriculture  

Energy Technology Data Exchange (ETDEWEB)

In the laboratory of Elementary Particle Physics and Detectors at the Faculty of Physics and Nuclear Techniques of the University of Mining and Metallurgy, research works on the development of proportional counters for the detection of X- and soft {gamma}-rays and {alpha}, {beta} particles have been carried out As a result of optimization of counters characteristic parameters such as: energy resolution, life time, count rate effect and temperature effect the operating stability has been reached and the elaborated detectors have been applied not only in research laboratories, but also in Polish industry, medicine and agriculture. Examples of above mentioned applications have been presented in the paper. (author). 7 refs, 7 figs, 1 tab.

1996-12-31

394

Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea  

Science.gov (United States)

The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.

2011-09-01

395

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

396

A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))

1994-09-01

397

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

398

A 40 GByte/s read-out system for GEM  

Energy Technology Data Exchange (ETDEWEB)

The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System.

1994-04-01

399

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

400

Photoresponsivity of ultraviolet detectors based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloys  

Energy Technology Data Exchange (ETDEWEB)

We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 {mu}m In{sub x}Al{sub y}Ga{sub 1-x-y}N alloy grown on 0.5-1.0 {mu}m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In{sub x}Al{sub y}Ga{sub 1-x-y}N detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and ...

2000-08-07

401

Photoresponsivity of ultraviolet detectors based on In_xAl_yGa_1_-_x_-_yN quaternary alloys  

International Nuclear Information System (INIS)

We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In_xAl_yGa_1_-_x_-_yN quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 #mu#m In_xAl_yGa_1_-_x_-_yN alloy grown on 0.5-1.0 #mu#m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In_xAl_yGa_1_-_x_-_yN detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In_xAl_yGa_1_-_x_-_yN quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to lattice mismatch with ...

2000-08-07

402

Ultratrace determination in high-purity molybdenum and tungsten with ion chromatographic trace-matrix-separation. Pt. 1; Selection and optimization of the separation step. Ultraspurenanalytik in hochreinem Molybdaen und Wolfram mit ionenchromatographischer Spuren-Matrix-Trennung. Tl. 1; Auswahl und Optimierung des Trennschritts  

Energy Technology Data Exchange (ETDEWEB)

Known trace-matrix-separation and enrichment procedures for the refractory metals Mo and W use very time-consuming batch-techniques. This paper presents the application of a quasicontinuous liquid chromatographic (LC) technique as a step towards automated ultratrace separation. The anionic peroxo complexes from Mo(VI) and W(VI) are used for the trace-matrix-separation. Optimization of the peroxide concentration permits a complete removal of all cationic analyte traces on the HPLC-suitable cation exchanger Nucleosil SA. The high chromato-graphic efficiency also allows a direct ion chromatographic separation of the removed traces. This leads to conclusions about the contribution of the analyte traces on the trace-matrix-separation column and the limits of determination. (author). 13 refs.; 12 figs.; 5 tabs.

1991-11-20

403

Ternary oxide nanostructures and methods of making same  

Energy Technology Data Exchange (ETDEWEB)

A single crystalline ternary nanostructure having the formula A.sub.xB.sub.yO.sub.z, wherein x ranges from 0.25 to 24, and y ranges from 1.5 to 40, and wherein A and B are independently selected from the group consisting of Ag, Al, As, Au, B, Ba, Br, Ca, Cd, Ce, Cl, Cm, Co, Cr, Cs, Cu, Dy, Er, Eu, F, Fe, Ga, Gd, Ge, Hf, Ho, I, In, Ir, K, La, Li, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, Os, P, Pb, Pd, Pr, Pt, Rb, Re, Rh, Ru, S, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Tc, Te, Ti, Tl, Tm, U, V, W, Y, Yb, and Zn, wherein the nanostructure is at least 95% free of defects and/or dislocations.

2009-09-08

404

Sodium to sodium carbonate conversion process  

Energy Technology Data Exchange (ETDEWEB)

A method is described for converting radioactive alkali metal into a low level disposable solid waste material. The radioactive alkali metal is atomized and introduced into an aqueous caustic solution having caustic present in the range of from about 20 wt % to about 70 wt % to convert the radioactive alkali metal to a radioactive alkali metal hydroxide. The aqueous caustic containing radioactive alkali metal hydroxide and CO{sub 2} are introduced into a thin film evaporator with the CO{sub 2} present in an amount greater than required to convert the alkali metal hydroxide to a radioactive alkali metal carbonate, and thereafter the radioactive alkali metal carbonate is separated from the thin film evaporator as a dry powder. Hydroxide solutions containing toxic metal hydroxide including one or more metal ions of Sb, As, Ba, Be, Cd, Cr, Pb, Hg, Ni, Se, Ag and Tl can be converted into a low level non-hazardous waste using the thin film evaporator of the invention. 3 ...

1997-10-14

405

Radiation methods in research of ancient monuments  

Energy Technology Data Exchange (ETDEWEB)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray fluorescence analysis has ...

2000-11-15

406

Radiation methods in research of ancient monuments  

International Nuclear Information System (INIS)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray fluorescence analysis has been chosen as the ...

2000-11-15

407

Quantification of "2"3"5U and "2"3"8U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional ...

2011-06-01

408

NOAA National Status and Trends Program Tenth Round Intercomparison for Trace Metals in Marine Sediments and Biological Tissues. National Status and Trends Program for marine environmental quality: Technical memo  

Energy Technology Data Exchange (ETDEWEB)

A total of forty participants were included in the exercise, including NOAA, USEPA, state, Australian, Canadian, Mexican and Argentinean laboratories. Two samples were sent by NRC to each participant: a contaminated marine sediment from the vicinity of New York Bay and a freeze dried mussel (Mytilus edulis) from Charlottenlund, Denmark. Laboratories were also asked to analyze two certified reference materials NIST SRM 1566a, and NRC BCSS-1. The elements to be determined were Al, Cr, Fe, Ni, Cu, Zn, As, Se, Ag, Cd, Sn, Hg, and Pb for both matrices, plus Be, Si, Mn, Sb, and Tl for the sediments. An accepted mean and confidence interval were calculated for each analyte in the two unknown samples. Laboratory biases were identified and an overall rating of superior, good, fair or others was assigned to each laboratory.

1996-11-01

409

NMR study of Ba2"+ ion motion in one-dimensional ionic conductor with hollandite-type structure  

International Nuclear Information System (INIS)

Ionic motion of a divalent cation, Ba"2"+, in a single crystal of Ba-Al-priderite was studied using "2"7Al as an NMR probe. Several pairs of satellite peaks due to electric quadrupole interaction were observed superposed on broad satellite tails on both sides of the main peak of "2"7Al. These peak pairs indicate the existence of some stable three-dimensional configurations of Ba"2"+ ions in the structure, and the broad shoulders show a random substitution of Al"3"+ for Ti"4"+ sites. The temperature dependence of the spin-lattice relaxation time T"*_l measured in the temperature range from 161 to 1176 K was analyzed by a curve fitting method on the assumption that there are two types of Ba"2"+ ions. An activation energy of 0.47 eV was obtained for the motion of Ba"2"+ ions which are easy to move, and a broad distribution of activation energies spread over a range from 0.95 to 2.45 eV was obtained for the motion of Ba"2"+ ions which form a three-dimensional honeycomb ...

410

Luminescence of CaGa2Se4:Eu crystals  

International Nuclear Information System (INIS)

We have studied photoluminescence and thermoluminescence (PL and TL) in CaGa2Se4:Eu crystals in the temperature range 77-400 K. We have established that broadband photoluminescence with maximum at 571 nm is due to intracenter transitions 4f6 5d-4f7 (8S7/2) of the Eu2+ ions. From the temperature dependence of the intensity (log I-103/T), we determined the activation energy (Ea = 0.04 eV) for thermal quenching of photoluminescence. From the thermoluminescence spectra, we determined the trap depths: 0.31, 0.44, 0.53, 0.59 eV. The lifetime of the excited state 4f6 5d of the Eu2+ ions in the CaGa2Se4 crystal found from the luminescence decay kinetics is 3.8 ?sec. (authors)

411

IAEA RESEARCH CONTRACTS SECOND ANNUAL REPORT. Technical Reports Series No. 9  

Science.gov (United States)

Summaries are presented for those research contracts which expired between December 31, 1960 and December 31, 1981. Topics covered include: factors controlling distribution of fission products in biosphere, non-destructive methods of evaluating the U/sup 235/ and Pu content of irradiated fuel elements, studies of contamination in local marine resources, tracer studies of anemia, non-destructive analysis of irradiated fuel elements using a flux integrating monitor, mechanism of proteolysis of I/sup 131/-labeled fibrinogen, radiosensitivity of spermatogonia of Drosophila melel elements by gamma scanning, uptake and loss of radioactive material by marine bacteria, factors which influence the movement of radioactive strontium from soils to plants, biological concentration of fission products in mollusks from water, decay scheme of Tl/sup 210/, calcium balance in metabolic bone disease, development of radioactive drugs with special reference ...

1962-01-01

412

Comparative action spectrum for ultraviolet light killing of mouse melanocytes from different genetic coat color backgrounds  

International Nuclear Information System (INIS)

The photobiology of mouse melanocyte lines with different pigment genotypes was studied by measuring colony-forming ability after irradiation. The cell lines were wild-type black (melan-a) and the mutants brown (melan-b) and albino (melan-c). Four lamps emitting various UV wavelengths were used. These were germicidal (UVC, 200-280 nm), 82.3% output at 254 nm, TL01 (UVB, 280-320 nm), 64.2% at 310-311 nm, FS20, broadband with peak output at 312 nm and Alisun-S (UVA, 320-400 nm), broadband with peak output at 350-354 nm. Appropriate filtration reduced the contaminating UVC to nonlethal levels for the longer waverange lamps. It is clear from these studies that, in pigment cells, monochromatic results cannot predict polychromatic responses and that cell death from solar irradiations is a complex phenomenon that depends on more than DNA damage. (author).

1997-01-01

413

Year-long comparison of two techniques to monitor outdoor radon concentrations at Shiprock, New Mexico  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...

1988-08-01

414

Temperature dependence of the performance of ultraviolet detectors  

Energy Technology Data Exchange (ETDEWEB)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the ...

2003-08-21

415

Temperature dependence of the performance of ultraviolet detectors  

International Nuclear Information System (INIS)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the ...

2003-08-21

416

Subcriticality measurements for two coupled uranyl nitrate solution tanks using /sup 252/Cf-source-driven neutron noise analysis methods  

Energy Technology Data Exchange (ETDEWEB)

The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different cylinders, a model which ...

1986-01-01

417

Reactivity surveillance experiments with the engineering mock-up core of the fast flux test facility reactor  

International Nuclear Information System (INIS)

An experiment was performed with a mock-up of the core of the Fast Flux Test Facility (FFTF) reactor to evaluate three reactivity measurement methods for application to liquid-metal fast breeder reactors (LMFBR): modified source multiplication measurements with the low-level flux monitor for refueling (35 dollars subcritical) of FFTF, noise analysis to 35 dollars subcritical, and inverse kinetics rod drop to 12 dollars subcritical. To investigate the spatial dependence of these measurement methods and to resolve discrepancies previously reported, detectors were placed in the core, reflector, and radial shield, and experimental data were collected with the reactivity at near delayed criticality to 35 dollars subcritical. Conclusions from this experiment are the following. Low-level flux monitors in the shield of the FFTF will be adequate for reactivity surveillance during refueling, using the modified source multiplication method calibrated near critical by an ...

418

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 ...

1993-10-13

419

HALO - the helium and lead observatory for supernova neutrinos  

Energy Technology Data Exchange (ETDEWEB)

The Helium and Lead Observatory (HALO) is a supernova neutrino detector under development for construction at SNOLAB. It is intended to fulfill a niche as a long term, low cost, high livetime, and low maintenance, dedicated supernova detector. It will be constructed from 80 tonnes of lead, from the decommissioning of the Deep River Cosmic Ray Station, and instrumented with approximately 384 meters of {sup 3}He neutron detectors from the final phase of the SNO experiment. Charged- and Neutral-Current neutrino interactions in lead expel neutrons from the lead nuclei making a burst of detected neutrons the signature for the detection of a supernova. Existing neutrino detectors are mostly of the water Cerenkov and liquid scintillator types, which are primarily sensitive to electron anti-neutrinos via charged-current interactions on the hydrogen nuclei in these materials. By contrast, the large neutron ...

2008-11-01

420

Considerations for the next Compton telescope mission  

International Nuclear Information System (INIS)

A high resolution Compton telescope has been identified by the Gamma Ray Astronomy Program Working Group (GRAPWG) as the highest priority major mission in gamma ray astrophysics following GLAST. This mission should provide 25-100 times improved sensitivity, relative to CGRO and INTEGRAL, for MeV gamma ray lines. It must have good performance for narrow and broad lines and for discrete and diffuse emissions. Several instrumental approaches are being pursued to achieve these goals. We discuss issues relating to this mission including alternative detector concepts, instrumental configurations, and background reduction techniques. We have pursued the development of position-sensitive solid-state detectors (Ge, Si) for a high spectral resolution Compton telescope mission. A #approx#1 m2 germanium Compton telescope of position-sensitive germanium detectors was the basis for one of the GRAPWG concepts. Preliminary Monte Carlo ...

2000-04-12

421

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional ...

2010-09-07

422

Basic study of entire whole-body PET scanners based on the OpenPET geometry  

International Nuclear Information System (INIS)

A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, ...

2010-09-01

423

Track Reconstruction and Performance of DRIFT Directional Dark Matter Detectors using Alpha Particles  

CERN Document Server

First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alpha particles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.

2007-01-01

424

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built ...

2004-10-13

425

TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams  

International Nuclear Information System (INIS)

A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in ...

2010-03-11

426

Study of core collapse neutrino signals and constraints on neutrino masses from a future Galactic Supernova  

CERN Document Server

We study the sensitivity to neutrino masses of a Galactic supernova neutrino signal as could be measured with the detectors presently in operation and with future large volume water \\v{C}erencov and scintillator detectors. The analysis uses the full statistics of neutrino events. The method proposed uses the principles of Bayesian inference reasoning and has shown a remarkably independence of astrophysical assumptions. We show that, after accounting for the uncertainties in the detailed astrophysical description of the neutrino signal and taking into account the effects of neutrino oscillations in the supernova mantle, detectors presently in operation can have enough sensitivity to reveal a neutrino mass (or to set upper limits) at the level of 1 eV. This is sensibly better than present results from tritium $\\beta$-decay experiments, competitive with the most conservative limits from neutrinoless double $\\beta$-decay and ...

2005-01-01

427

Research in heavy-ion nuclear physics. [Dept. of Physics and Astronomy, The Univ. of Kansas, Lawrence, Kansas  

Energy Technology Data Exchange (ETDEWEB)

Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to [sup 47]V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of [sup 28]Al through three different entrance channels. Angular distributions are shown for different mass channels of the [sup 29]Si+[sup 27]Al reaction at E[sub lab] = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the [sup 24]Mg+[sup 24]Mg reaction; cross sections for binary fragment emission are shown for E[sub lab] = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.

1992-01-01

428

Research in heavy-ion nuclear physics. Annual progress report, May 1, 1992--April 30, 1993  

Energy Technology Data Exchange (ETDEWEB)

Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to {sup 47}V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of {sup 28}Al through three different entrance channels. Angular distributions are shown for different mass channels of the {sup 29}Si+{sup 27}Al reaction at E{sub lab} = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the {sup 24}Mg+{sup 24}Mg reaction; cross sections for binary fragment emission are shown for E{sub lab} = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.

1992-01-01

429

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a planar Si(Li) detector. ...

1989-06-01

430

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light ...

1992-10-25

431

National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards  

International Nuclear Information System (INIS)

As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of nuclear materials. ...

2009-12-16

432

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons ...

2004-03-09

433

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification ...

1997-12-31

434

Micro-strip metal foil detectors for the beam profile monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.

2005-07-01

435

Methods of selection in heavy ion collisions at Fermi energies and de-excitation modes with the INDRA multi-detector; Methodes de tri dans les collisions d'ions lourds aux energies de Fermi et modes de desexcitation avec le multidetecteur INDRA  

Energy Technology Data Exchange (ETDEWEB)

The progress made in particle detection, particularly the design of multi-detectors, like INDRA, that cover a solid angle of almost 4{pi}, have given a new impetus to heavy ion collisions. These detectors are demanding for an efficient way of selecting events that have a common history or similar features, for instance the events representing the de-excitation of a unique emitter. The problem is to find the adequate variable on which the discrimination can be based. Different methods are proposed in this work, the common point is that they require efficient models to reproduce and analyse experimental data in order to apprehend the equation of state of nuclear matter. Most of these models are based on the numerically solving of the nuclear Boltzmann equation. The application to the Ni + Ni reaction with an energy ranging from a few A.MeV to more than 50 A.MeV illustrates this work. (A.C.)

2005-11-15

436

Launch of the Space experiment PAMELA  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In ...

2007-01-01

437

Investigation of the frequency-dependence of the MTC noise estimator  

International Nuclear Information System (INIS)

The Moderator Temperature Coefficient of reactivity (MTC) was earlier proven to be properly determined via noise analysis when the neutron noise is measured locally and when the radial average of the moderator temperature noise is used. Nevertheless, measurements revealed that the MTC was correctly estimated on a much narrower frequency band (0.6 - 0.7 Hz) than expected (0.1 - 1.0 Hz). The present paper investigates the effect of the feedback on the MTC determination using this new MTC noise estimator (which could explain the deviation at low frequencies, i.e. between 0.1 - 0.5 Hz) and the effect of the detector time constants (which could explain the deviation at high frequencies, i.e. between 0.7 - 1.0 Hz). For that purpose, a coupled neutronic/thermalhydraulic model of the Ringhals-3 PWR is developed in the frequency-domain, based on a radial 2-dimensional heterogeneous representation of the core. The transfer function of the detectors is ...

2005-09-12

438

Interim cryo-cooler/detector report  

Energy Technology Data Exchange (ETDEWEB)

This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital signal processor ...

1995-04-19

439

Indoor and outdoor Radon concentration measurements in Sivas, Turkey, in comparison with geological setting  

Energy Technology Data Exchange (ETDEWEB)

Indoor and soil gas Radon ({sup 222}Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor {sup 222}Rn gas concentration values. In the second stage, soil gas {sup 222}Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although {sup 222}Rn concentrations in Sivas were quite low in relation with the ...

2010-11-15

440

Emergency core cooling device  

International Nuclear Information System (INIS)

In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, ...

1990-10-29

441

Edge filter and fringe imaging for laser Doppler wind speed measurement  

Science.gov (United States)

Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of ...

1997-08-01

442

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires to discriminate between the neutron events ...

1997-07-01

443

Construction and Calibration of the Laser Alignment System for the CMS Tracker  

CERN Document Server

The CMS detector (Compact Muon Solenoid) is under construction at one of the four proton-proton interaction points of the LHC (Large Hadron Collider) at CERN, the European Organization for Nuclear Research (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 m and a length of 5.4 m representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 m2 to detect charged particles from proton collisions. They are placed on a rigid carbon fibre structure, providing stability within the working conditions of a 4 T solenoid magnetic field at ?10oC. Knowledge of the position of the silicon detectors at the level of 100 ?m is needed for an efficient pattern recognition of charged particle tracks. Metrology methods are used to survey tracker subdetectors and the integrated Laser Alignment System (LAS) ...

2006-01-01

444

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

445

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of ...

2005-01-01

446

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat ...

2003-08-17

447

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative contribution of accelerator ...

448

A Risk-Based Sensor Placement Methodology  

Energy Technology Data Exchange (ETDEWEB)

A risk-based sensor placement methodology is proposed to solve the problem of optimal location of sensors or detectors to protect population against the exposure to and effects of known and/or postulated chemical, biological, and/or radiological threats. Risk is calculated as a quantitative value representing population at risk from exposure against standard exposure levels. Historical meteorological data are used to characterize weather conditions as the frequency of wind speed and direction pairs. The meteorological data drive atmospheric transport and dispersion modeling of the threats, the results of which are used to calculate risk values. Sensor locations are determined via an iterative dynamic programming algorithm whereby threats captured or detected by sensors placed in prior stages are removed from consideration in subsequent stages. In addition to the risk-based placement algorithm, the proposed methodology provides a quantification of the marginal ...

2008-10-01

449

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...

450

Use of neural network techniques to identify cosmic ray electrons and positrons during the 1993 balloon flight of the NMSU/Wizard-TS93 instrument  

Energy Technology Data Exchange (ETDEWEB)

The detectors used in the TS93 balloon flight produced a large volume of information for each cosmic ray trigger. Some of the data was visual in nature, other portions contained energy deposition and timing information. The data sets are amenable to conventional analysis techniques but there is no assurance that conventional techniques make full use of subtle correlations and relations amongst the detector responses. With the advent of neural network technologies, particularly adept at classification of complex phenomena, it would seem appropriate to explore the utility of neural network techniques to classify particles observed with the instruments. In this paper neural network based methodology for signal/background discrimination in a cosmic ray space experiment is discussed. Results are presented for electron and positron classification in the TS93 flight data set and will be compared to conventional analyses.

1995-09-01

451

The BAIKAL Neutrino Experiment: From NT200 to NT200+  

CERN Document Server

The Baikal Neutrino Telescope has been operating in its NT200 configuration since April, 1998. The telescope has been upgraded in April, 2005, to the 10 Mton scale detector NT200+. It's main physics goal is the detection of signals from high energy neutrino cascades. NT200+ reaches a 3-year sensitivity of 2 \\times 10^{-7}cm^{-2}s^{-1}sr^{-1}GeV for an all-flavor diffuse cosmic E^{-2} neutrino flux for energies 10^2 TeV \\div 10^5 TeV. Desgin and sensitivity of NT200+ are described. NT200+ is forming the basic building block of a future km3-scale (Gigaton-Volume) Baikal Telescope. Research and development work on that next stage detector has started.

2006-01-01

452

Tachyons and experimental physics  

International Nuclear Information System (INIS)

An experimentalist looking for free tachyons is faced with the following two related problems: A) How does a tachyon interact with bradyonic matter. Is it an object more or less localized in space-time. B) How should a (bradyonic) detector for tachyons look. To answer B) you should necessarily know something about A). But a theory which provides sufficient information doesn't exist at the moment. Therefore it is necessary to make some simple assumption to tackle problem B). In the second part of this contribution two possibilities of tachyon detectors are proposed assuming that a free charged tachyon (if it exists) exhibits normal electromagnetic interaction with bradyonic matter. Another possibility to look for tachyons produced in high energy reactions of bradyons is the missing mass method using the fact that the four-momentum of a collection of particles can be spacelike if at least one tachyon is present. Such experiments have been ...

453

Study of point defect detectors in Si  

International Nuclear Information System (INIS)

The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well

1999-05-01

454

Search for tachyons associated with EAS at energies E>=3x10"1"6eV  

International Nuclear Information System (INIS)

This paper describes an experiment which has been performed with a somewhat different philosophy in its approach as compared to previous work. (a) The trigger threshold energy was increased by more than a factor of ten on previous experiments reducing the dilution effect of many lower energy showers known not to produce tachyons. 1673 shower were recorded. (b) The exposure time was made longer than previous experiments in order to obtain a reasonably large statistical sample at the higher threshold. Observations were made between February 1979 and June 1980, the total live time being 9768 hours. (c) Records of the detector output amplitude for the 480#mu#s lead time were integrated point by point as is sometimes done in radio astronomy, this gives the integrated energy deposition within the detector.

455

SENSITIVITY STUDIES FOR AN IN-SITU PARTIAL DEFECT DETECTOR (PDET) IN SPENT FUEL USING MONTE CARLO TECHNIQUES  

Energy Technology Data Exchange (ETDEWEB)

This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.

2008-04-28

456

Results from Amanda  

Energy Technology Data Exchange (ETDEWEB)

In this report we present an update on the results from the Amanda-B10 detector which operated in 1997 at depths of 1500 to 2000 meters in the deep Antarctic ice. The goal of Amanda project is to search for extra-terrestrial neutrinos. As a precursor to such a search we have studied atmospheric neutrinos which act as a calibration source for the detector. The observation of atmospheric neutrinos at a rate consistent with Monte-Carlo predictions establishes Amanda-B10 as a neutrino telescope. The Amanda-B10 data has been searched for evidence of several classes of neutrinos and for magnetic monopoles. Searches for a diffuse high energy neutrino flux and for neutrinos in coincidence with gamma-ray bursts have been conducted. Preliminary data analyses show no excess of neutrinos has been found. (A.C.)

2001-07-01

457

Radon measurements at the FEMP  

Energy Technology Data Exchange (ETDEWEB)

Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.

1993-08-01

458

Radon diffusion studies through building construction materials using solid state nuclear track detectors  

International Nuclear Information System (INIS)

Radon appears mainly by diffusion processes from the point of origin following #alpha#- decay of "2"2"6Ra in underground soil and building materials used, in the construction of floors, walls, and ceiling. The transport phenomenon of radon through diffusion is a significant contributor to indoor radon entry. In the present study radon diffusion through sand, cement, mixtures of sand + cement (1:1), sand + cement (2:1), sand + cement (3:1), sand + cement (4:1) has been carried out using LR-115 type II solid state nuclear track detectors (SSNTDs). The radon diffusion coefficient and diffusion lengths have been calculated for different materials. The effect of compaction, which changes the porosity and permeability of the materials, on radon diffusion has also been studied. (author)

2003-10-16

459

Quantification of thin film crystallographic orientation using X-ray diffraction with an area detector  

Energy Technology Data Exchange (ETDEWEB)

As thin films become increasingly popular (for solar cells, LEDs, microelectronics, batteries), quantitative morphological information is needed to predict and optimize the film's electronic, optical and mechanical properties. This quantification can be obtained quickly and easily with X-ray diffraction using an area detector and synchrotron radiation in two simple geometries. In this paper, we describe a methodology for constructing complete pole figures for thin films with fiber texture (isotropic in-plane orientation). We demonstrate this technique on semicrystalline polymer films, self-assembled nanoparticle semiconductor films, and randomly-packed metallic nanoparticle films. This method can be immediately implemented to help understand the relationship between film processing and microstructure, enabling the development of better and less expensive electronic and optoelectronic devices.

2010-02-19

460

Progress Report Towards the ICANOE Detector  

CERN Document Server

We present a proposal for a combined ICARUS & NOE general purpose detector, to be installed in Hall B of the Gran Sasso Laboratory.The main scientific goal is the one of elucidating in a comprehensive way the pattern of neutrino $9 masses and mixings, following both (1) the S-KAM results and (2) the predictions on atmospheric neutrinos of the large solution of the Solar Neutrinos deficit. To achieve these goals, the experimental method is based upon the $9 complementary and simultaneous detection of CERN beam (CNGS) and cosmic ray (CR) events. This is made possible because of the complete isotropy of the detection technique. For the currently allowed values of the S-KAM results, both $9 CNGS and cosmic ray data will give independent measurements and provide a precise $(sin^{2}2\\theta; \\Delta m^{2})$ determination rather than a wide band of allowed values. Since we can observe and unambiguously identify $9 $\

1999-01-01

461

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

462

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

463

Possible applications of plasma lens in high energy physics  

Energy Technology Data Exchange (ETDEWEB)

The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition {ital k}{sub {ital p}}{sigma}{sub {ital x}}{approx_gt}1, and not {ital k}{sub {ital p}}{sigma}{sub {ital y}}{approx_gt}1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for {gamma}{gamma} colliders is discussed.{copyright}{ital American Institute of Physics.}

1996-01-01

464

Possible applications of plasma lens in high energy physics  

International Nuclear Information System (INIS)

The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition k_p#sigma#_x approx-gt 1, and not k_p#sigma#_y approx-gt 1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for #gamma##gamma# colliders is discussed.copyright American Institute of Physics.

465

Performance of a Bragg curve detector for heavy ion identification  

Energy Technology Data Exchange (ETDEWEB)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.

1982-12-15

466

Performance of a Bragg curve detector for heavy ion identification  

International Nuclear Information System (INIS)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).

467

Non-standard antineutrino interactions at Daya Bay  

CERN Document Server

We study the prospects of pinning down the effects of non-standard antineutrino interactions in the source and in the detector at the Daya Bay neutrino facility. It is well known that if the non-standard interactions in the detection process are of the same type as those in the production, their net effect can be subsumed into a mere shift in the measured value of the leptonic mixing angle theta_13. Relaxing this assumption, the ratio of the antineutrino spectra measured by the Daya Bay far and near detectors is distorted in a characteristic way, and good fits based on the standard oscillation hypothesis are no longer viable. We show that, under certain conditions, three years of Daya Bay running can be sufficient to provide a clear hint of non-standard neutrino physics.

2011-01-01

468

Neutrino cross sections with the MINER?A Experiment  

British Library Electronic Table of Contents (United Kingdom)

MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...

2011-01-01

469

Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.

1990-01-01

470

Measurement of W{sup {+-}} boson mass at LEP by means of DELPHI detector; Mesure de la masse des bosons W{sup {+-}} au LEP a l`aide du detecteur DELPHI  

Energy Technology Data Exchange (ETDEWEB)

The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.

1998-05-25

471

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

472

Linac automated beam phase control system.  

Energy Technology Data Exchange (ETDEWEB)

Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up operations.

2006-01-01

473

Information flow, causality, and the classical theory of tachyons  

International Nuclear Information System (INIS)

Causal paradoxes arising in the tachyon theory have been systematically solved by using the reinterpretation principle as a consequence of which cause and effect no longer retain an absolute meaning. However, even in the tachyon theory, a cause is always seen to chronologically precede its effect, but this is obtained at the price of allowing cause and effect to be interchanged when required. A recent result has shown that this interchange-ability of cause and effect must not be unlimited if heavy paradoxes are to be avoided. This partial recovery of the classical concept of causality has been expressed by the conjecture that transcendent tachyons cannot be absorbed by a tachyon detector. In this paper the directional properties of the flow of information between two observers in relative motion and its consequences on the logical self-consistency of the theory of superluminal particles are analyzed. It is shown that the above conjecture does not provide a ...

474

Gas sensor arrays (electronic noses) and their combination with trap techniques  

Energy Technology Data Exchange (ETDEWEB)

In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)

2001-07-01

475

Gamma-rays and neutrinos from the pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab Nebula.

2005-08-01

476

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may be employed to identify the presence of ...

1991-10-02

477

Experimental limits on quarks, tachyons, and massive particles in cosmic rays  

Energy Technology Data Exchange (ETDEWEB)

A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45/sup 0/ and 90/sup 0/. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10/sup -10/ and 2.6 x 10/sup -10/ cm/sup -2/sr /sup -1/ sec/sup -1/, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10/sup -9/ cm/sup -2/ sr/sup -1/ sec/sup -1/. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.

1982-10-01

478

Experimental limits on quarks, tachyons, and massive particles in cosmic rays  

International Nuclear Information System (INIS)

A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45"0 and 90"0. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10"-"1"0 and 2.6 x 10"-"1"0 cm"-"2sr "-"1 sec"-"1, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10"-"9 cm"-"2 sr"-"1 sec"-"1. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.

479

Empirical relationship between track diameter and etching time for fission fragments incident on a glass SSNTD at various angles of incidence  

Energy Technology Data Exchange (ETDEWEB)

Geometrical shapes and diameter of nuclear tracks changes continuously during the process of etching for various incident angles. Besides, there is also a marked difference amongst their profiles, as evidenced by the SEM analysis, when the incoming particles fall on the detector at different angles of incidence. This work outlines this aspect of fission fragment tracks in a glass detector and has set out a few empirical relationships between the mean track diameter, d-bar and the etching time, t, within experimental limits. This study, therefore, sheds some light in the follow up the origins and characteristics of heavy ions in some terrestrial and extra-terrestrial materials and also in studying the collimation accuracy of heavy ion bombardments. The implications of the results in discerning the measurements of incident angles of various types of ions are described in detail in the paper.

1983-09-01

480

Discriminating between a Stochastic Gravitational Wave Background and Instrument Noise  

CERN Document Server

The detection of a stochastic background of gravitational waves could significantly impact our understanding of the physical processes that shaped the early Universe. The challenge lies in separating the cosmological signal from other stochastic processes such as instrument noise and astrophysical foregrounds. One approach is to build two or more detectors and cross correlate their output, thereby enhancing the common gravitational wave signal relative to the uncorrelated instrument noise. When only one detector is available, as will likely be the case with the Laser Interferometer Space Antenna (LISA), alternative analysis techniques must be developed. Here we show that models of the noise and signal transfer functions can be used to tease apart the gravitational and instrument noise contributions. We discuss the role of gravitational wave insensitive "null channels" formed from particular combinations of the time delay interferometry, and ...

2010-01-01

481

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

482

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

483

Comparison of energy flows in deep inelastic scattering events with and without a large rapidity gap  

Energy Technology Data Exchange (ETDEWEB)

Energy flows in deep inelastic electron-proton scattering are investigated at a centre-of-mass energy of 296 GeV for the range Q{sup 2}{>=}10 GeV{sup 2} using the ZEUS detector. A comparison is made between events with and without a large rapidity gap between the hadronic system and the proton direction. The energy flows, corrected for detector acceptance and resolution, are shown for these two classes of events in both the HERA laboratory frame and the Breit frame. From the differences in the shapes of these energy flows we conclude that QCD radiation is suppressed in the large-rapidity-gap events compared to the events without a large rapidity gap. (orig.)

1994-07-01

484

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an accurate prediction of the performance of a concentrating solar ...

1980-01-01

485

Apparatus for in situ determination of burnup cooling time and fissile content of an irradiated nuclear fuel assembly in a fuel storage pond  

Energy Technology Data Exchange (ETDEWEB)

A detector head for in situ inspection of irradiated nuclear fuel assemblies submerged in a water-filled nuclear fuel storage pond. The detector head includes two parallel arms which extend from a housing and which are spaced apart so as to be positionable on opposite sides of a submerged fuel assembly. Each arm includes an ionization chamber and two fission chambers. One fission chamber in each arm is enclosed in a cadmium shield and the other fission chamber is unshielded. The ratio of the outputs of the shielded and unshielded fission chambers is used to determine the boron content of the pond water. Correcting for the boron content, the neutron flux and gamma ray intensity are then used to verify the declared exposure, cooling time and fissile material content of the irradiated fuel assembly.

1985-04-09

486

An improved noise-robust voice activity detector based on hidden semi-Markov models  

British Library Electronic Table of Contents (United Kingdom)

To improve the performance of voice activity detector (VAD) in noisy environments, this paper concentrates on three critical aspects related to noise robustness including speech features, feature distributions and temporal dependence. Based on the statistic on TIMIT and NOIZEUS, Mel-frequency cepstrum coefficients (MFCCs) are selected as speech features, Gaussian Mixture distributions (GMD) are applied to associate the observations in MFCC domain with both speech and non-speech states, and Weibull and Gamma distributions are used to explicitly model noise and speech durations, respectively. To integrate these aspects into VAD, the hidden semi-Markov model (HSMM) as a generalized hidden Markov model (HMM) is introduced first. Then the VAD decision is made according to the likelihood ratio t...

2011-01-01

487

A search for resonant Z pair production  

Energy Technology Data Exchange (ETDEWEB)

I describe a search for anomalous production of Z pairs through a new massive resonance X in 2.5-2.9 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV using the CDFII Detector at the Fermilab Tevatron. I reconstruct Z pairs through their decays to electrons, muons, and quarks. To achieve perhaps the most efficient lepton reconstruction ever used at CDF, I apply a thorough understanding of the detector and new reconstruction software heavily revised for this purpose. In particular, I have designed and employ new general-purpose algorithms for tracking at large {eta} in order to increase muon acceptance. Upon analyzing the unblinded signal samples, I observe no X {yields} ZZ candidates and set upper limits on the production cross section using a Kaluza-Klein graviton-like acceptance.

2008-12-01

488

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate ...

1999-11-01

489

Radon measurements in the interior of the great pyramid  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).

1991-01-01

490

Operation and physics potential of Tevatron Run 2  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron Run 2 has begun. The Tevatron program in the next six years offers a real opportunity to significantly advance our understanding of the fundamental properties of the universe. It is an exciting, challenging program that goes straight to the highest priorities of high energy physics worldwide. The accelerator and detectors are being commissioned and seem to be performing well. We anticipate first physics results in the summer of 2002.

2001-12-07

491

Measuring equipment for the monitoring of air pollution control - a market review  

Energy Technology Data Exchange (ETDEWEB)

The paper abstracted gives a tabular survey of the suppliers and applications of measuring equipment. Equipment is available for the following fields of application: Continuous measuring instruments for stationary operation, laboratory equipment for sampling and hand equipment for mobile measurement, sampling equipment for examining emissions and gases, detectors, storage and evaluation equipment and meteorological instruments. (PW).

1986-01-01

492

LC-MS analysis in the e-beam and gamma radiolysis of metoprolol tartrate in aqueous solution: Structure elucidation and formation mechanism of radiolytic products  

British Library Electronic Table of Contents (United Kingdom)

E-beam and gamma products from the radiolysis of aqueous solutions of (+-)-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of (+-)-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.

2006-01-01

493

In-beam conversion electron spectroscopy using the SACRED array  

International Nuclear Information System (INIS)

Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.

494

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

495

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest (the ratio of spectral ...

1980-01-01

496

Calibration of cylindrical detectors using a simplified theoretical approach  

Energy Technology Data Exchange (ETDEWEB)

The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a new theoretical ...

2006-09-15

497

ATLAS tile calorimeter electronics upgrade  

CERN Document Server

This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.

2011-01-01

498

A search for tachyons in cosmic ray showers  

International Nuclear Information System (INIS)

A search has been made of tachyons associated with cosmic ray showers of energies about 10"1"5 eV by searching for any precursor effects observed in plastic scintillator detectors. Detection thresholds well below most other similar experiments have been reached but no statistically significant effects have been found.