Treatment of produced water using hydrocyclones; Tratamento de agua produzida usando hidrociclone  

Energy Technology Data Exchange (ETDEWEB)

Beyond a great number of applications in mineral process, the hydrocyclone separation has been used recently in an increasing number of fields, such as: environmental engineering, petrochemical engineering, food engineering, electrochemical engineering, pulp bioengineering, processes and paper industries, among others. Nowadays, the produced water is treated and then reinjected in the surface and also in return to the formation. In the offshore platforms, the produced water can be directly discarded in the ocean, since the dispersed phase concentration (oil) is according to Brazilian regulating agency limits. The basic principle used in hydrocyclone separation is the centrifugal sedimentation machine: the suspended particles are submitted to centrifugal acceleration, which separates them from the fluid. The basic geometry of a hydrocyclone consists of four parts: a cylindrical section for feeding, a conical section for ...

2008-07-01

2

Centrifugal Extractors for Medicine Production  

International Science & Technology Center (ISTC)

Continuous Countercurrent Process in Cascade of Centrifugal Extractors for Medicine Production

3

Solid deuterium centrifuge pellet injector  

Energy Technology Data Exchange (ETDEWEB)

Pellet injectors are needed to fuel long pulse tokamak plasmas and other magnetic confinement devices. For this purpose, an apparatus has been developed that forms 1.3-mm-diam pellets of frozen deuterium at a rate of 40 pellets per second and accelerates them to a speed of 1 km/s. Pellets are formed by extruding a billet of solidified deuterium through a 1.3-mm-diam nozzle at a speed of 5 cm/s. The extruding deuterium is chopped with a razor knife, forming 1.3-mm right circular cylinders of solid deuterium. The pellets are accelerated by synchronously injecting them into a high speed rotating arbor containing a guide track, which carries them from a point near the center of rotation to the periphery. The pellets leave the wheel after 150/sup 0/ of rotation at double the tip speed. The centrifuge is formed in the shape of a centrifugal catenary and is constructed of high strength KEVLAR/epoxy composite. This arbon has been ...

1982-01-01

4

Fine-ceramic anitifriction bearings  

Energy Technology Data Exchange (ETDEWEB)

Ceramic antifriction bearings were introduced in excellent characterics and application. In main shaft use bearings of the machine tool, to be heightened in efficiency and accuracy by the heightening in speed, centrifugal load to the outer ring is not negligible to shorten the bearing in life. Also ball bearings with a contact angle are easily corroded by a very strong revolution slide due to the gyromoment. The use of such light weight material as silicon nitride's can design the lengthening in life. Also the utilization of high rigidity can prevent the inner ring from expanding by centrifugal force and enable the machining to be with a high accuracy. Ceramic rolling element is excellent also in backing resistant property and effective on the oily film cut. With heat resistant property, it maintains hardness even at high temperature. Such excellent characteristics being utilized, the fine ceramic antifriction bearing is used for the ...

1989-08-01

5

Precipitation of ions induced by nonadiabatic motion in the outer cusp region  

Science.gov (United States)

The transport of magnetospheric particles in the outer cusp region is examined by means of three-dimensional single particle codes. It is shown that, at high altitudes, particles can experience nonadiabatic motions leading to significant magnetic moment changes. It is demonstrated that this nonadiabatic behavior can be interpreted, at least partly, by the action of an impulsive centrifugal force perturbing the particle gyromotion. Systematic trajectory calculations reveal that plasma sheet ions which ExB convert toward the magnetopause from low L-shells in the dayside sector are subjected to such nonadiabatic motions. As a result of magnetic moment damping, a number of them are injected into the loss cone and subsequently precipitate near the cusp equatorward edge.

6

Magnetic Fields in Massive Stars. II. The Buoyant Rise of Magnetic Flux Tubes Through the Radiative Interior  

CERN Document Server

We present results from an investigation of the dynamical behavior of buoyant magnetic flux rings in the radiative interior of a uniformly rotating early-type star. Our physical model describes a thin, axisymmetric, toroidal flux tube that is released from the outer boundary of the convective core, and is acted upon by buoyant, centrifugal, Coriolis, magnetic tension, and aerodynamic drag forces. We find that rings emitted in the equatorial plane can attain a stationary equilibrium state that is stable with respect to small displacements in radius, but is unstable when perturbed in the meridional direction. Rings emitted at other latitudes travel toward the surface along trajectories that largely parallel the rotation axis of the star. Over much of the ascent, the instantaneous rise speed is determined by the rate of heating by the absorption of radiation that diffuses into the tube from the external medium. Since the time ...

2003-01-01

7

Magnetic braking of collapsing interstellar clouds  

International Nuclear Information System (INIS)

The purpose of this investigation is to show that resource to anisotropic compression along a magnetic field is not a necessary condition for star formation within large collapsing interstellar gas clouds. Although such a scenario would certainly eliminate the magnetic field and angular momentum problems associated with isotropically collapsing clouds, it is believed there is sufficient observational theoretical evidence to warrant the present study of magnetically braked, isotropically collapsing gas clouds. It is not attempted to disprove the hypothesis of anisotropic compression, but to offer instead, a reasonable alternative. Angular momentum transfer from magnetically braked, cool interstellar gas clouds of 10"2, 10"3 and 10"4 times the mass of the sun is examined. Magnetic torques acting on a contracting, rotating cloud, permeated by a frozen-in magnetic ...

9

Autocontrol technique of combined centrifuges  

International Nuclear Information System (INIS)

The design characteristic of the autocontrol technique of the combined centrifuge is introduced. Digital technique, vary structure control and interface technique, graphical display techniques, digital communication technique as well as electronic technique are applied in the course of research. Automation in the operation of large scale combined centrifuges and the course of combined test has been realized and it can coordinate with other systems of status monitoring, data collecting and centrifugal force-aerodynamic force matched load automatically

2009-12-01

11

BIBRA "t"r"a"d"e"m"a"r"k - the biological treatment of radioactive waste water  

International Nuclear Information System (INIS)

BIBRA "t"r"a"d"e"m"a"r"k, is the new bio-technological method developed in Gundremmingen for treating radioactive waste water, using bacteria in a process analogous to the long-established principle of communal sewage treatment plants. The method exploits the behaviour of the micro-organisms found there, to establish optimum adaptation of their population for decomposing the typical pollutants found in this washing water. This procedure is particularly suitable for nuclear engineering plants, because in such plants the waste water composition changes little so that the bacteria can achieve optimum adaptation to this waste water. The organic ingredients of the washing media are decomposed by introducing air. The advantage of the procedure is not only the significant reduction of the amount of waste material, but also enhanced efficiency of the cleaning process. The decontamination factor in Gundremmingen improved from a factor of 5 to a factor of 20. The waste water is clear and free ...

1999-03-01

12

The protective antigens of equine herpesvirus type 1.  

UK PubMed Central (United Kingdom)

Equine herpesvirus type 1 was cultivated in swine testis cell cultures and partially purified by differential centrifugation and centrifugation in a linear sucrose density gradient. The viral envelope...Full Text Available

1978-04-01

13

Influence of geometry and operating conditions of a centrifugal compressor stage on the radial gas force  

British Library Electronic Table of Contents (United Kingdom)

The influence of geometry and operating conditions of the centrifugal compressor stage on the radial gas force is determined on the basis of the theoretical method and calculation program using experimental boundary conditions.

2011-01-01

14

A method for acetic processing of an electric, centrifugal well pump  

Energy Technology Data Exchange (ETDEWEB)

In order to reduce the length and to increase the effectiveness of processing, the proposed method for acetic processing of an electric centrifugal well pump calls for covering the pressure line during the curing and periodically starting the pump.

1983-01-01

15

Crystalline beam ground state  

Energy Technology Data Exchange (ETDEWEB)

In order to employ molecular dynamics (MD) methods, commonly used in condensed matter physics, we have derived the equations of motion for a beam of charged particles in the rotating rest frame of the reference particle. We include in the formalism that the particles are confined by the guiding and focusing magnetic fields, and that they are confined in a conducting vacuum pipe while interacting with each other via a Coulomb force. Numerical simulations using MD methods has been performed to obtain the equilibrium crystalline beam structure. The effect of the shearing force, centrifugal force, and azimuthal variation of the focusing strength are investigated. It is found that a constant gradient storage ring can not give a crystalline beam, but that an alternating-gradient (AG) structure can. In such a machine the ground state is, except for one-dimensional (1-D) crystals, time dependent. The ground state is a zero entropy state, despite the ...

1993-06-11

16

Lubricant wear particle analysis by filter patch extraction  

Energy Technology Data Exchange (ETDEWEB)

Lubricating Oil Analysis (LOA) has become an important part of a comprehensive Reliability Centered Maintenance (RCM) program. However, knowing the condition of the lubricant alone does not provide a complete description of equipment reliability. Condition monitoring for equipment can be accomplished through Wear Particle Analysis (WPA). This usually involves separating suspended materials and wear products from the lubricant by magnetic (ferrographic) means. This paper will present a simple, low-cost, alternate method of particle acquisition called Filter Patch Extraction (FPE). This method removes solids, regardless of their composition, from the lubricant by vacuum filtration and deposits them onto a filter for microscopic examination similar to that of analytical ferrography. A large filter pore size retains suspended materials and permits rapid filtration of large volumes of lubricant thereby increasing the accuracy of ...

1996-07-01

17

Centrifugal potential energy : an astounding renewable energy concept  

Energy Technology Data Exchange (ETDEWEB)

A new energy concept known as centrifugal potential energy was discussed. This new energy concept is capable of increasing the pressure, temperature and enthalpy of a fluid, without having to apply work or heat transfer to the fluid. It occurs through a change in the centrifugal potential energy of the flowing fluid in a rotating frame of reference or a centrifugal force field, where work is performed internally by the centrifugal weight of the fluid. This energy concept has resulted in new energy equations, such as the Rotational Frame Bernoulli's Equation for liquids and the Rotational Frame Steady-Flow Energy Equation for gases. Applications of these equations have been incorporated into the design of centrifugal field pumps and compressors. Rather than compressing a fluid with a physical load transfer, these devices can compress a fluid via the effect of ...

2010-07-01

18

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

19

The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type  

Energy Technology Data Exchange (ETDEWEB)

There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the chamber to readout the voltage. For operation conditions of the apparatus, observation ...

1999-09-01

20

The National Shipbuilding Research Program Task S-20: A ...  

Science.gov (United States)

... The other standards in this group deal with heat exchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...

1979-05-01

21

Force Required to Detach Conidia of Helminthosporium maydis  

UK PubMed Central (United Kingdom)

The force required to break the conidium-conidiophore attachment in Helminthosporium maydis was measured by centrifugation and by a small jet of air. The force which removed half the...Full Text Available

1975-01-01

22

Basic characteristics of centrifuges, (2)  

International Nuclear Information System (INIS)

The presence of an extraneous light gas must be taken into account in consideration of centrifugal separation of uranium isotopes, when there is inevitable leakage of such a gas through the gas sealant and/or leaking in from the atmosphere. Consideration is first given to the influence of the presence of the light gas on the maximum separative power. Then the basic equation for isotope separation containing a light gas is derived from Hirschfelder's diffusion equations. This equation is solved and the separative performance is expressed in terms of the shape factor and reflux parameter. The formulas for expressing the flow configurations of the gases are obtained for a simple model in which inflow and outflow prevail throughout the centrifuge. The corresponding equation for a model in which the gases flow in two concentric thin streams is also derived. It is concluded that the influence provided by the presence of a light gas is quite ...

23

Biogeo-Optics: Backscattering Cross Sections for Suspended ...  

Science.gov (United States)

... Mineral and Organic Matter in the Coastal and Near-Coastal Ocean. ... Personal Author(s) : Stavn, Robert H. ; Spiering, Bruce A. ; Gould, Richard W ...

2004-12-20

24

Molina: a non-linear code to compute the internal hydrodynamics of a gas centrifuge  

Energy Technology Data Exchange (ETDEWEB)

Uranium enrichment by gas centrifugation relies on the pressure diffusion of the isotopes when their gaseous mixture is submitted to the pressure diffusion in the strong radial pressure gradient due to the centrifugal force in a very rapidly rotating cylinder. To compute the isotope separation in a gas centrifuge, the viscous compressible Navier-Stokes equations are solved for the mixture, then the diffusion equations are solved for the isotopes. As far as the separation performance is concerned, the models deal with the steady state of the axi-symmetric gas motion in the rotating cylinder. The numerical tools are briefly presented: first, the MOLINA code which numerically solves the axi-symmetric gas motion in the specific conditions of rapid rotation by use of a change of variables suited to the high density gradient and by use of a Marker And Cell method; then, the diffusion equations solver which uses a Finite Volume ...

2003-07-01

25

The Hannover thermal noise experiment  

International Nuclear Information System (INIS)

To analyse the thermal noise of the pendulum mode of a suspended mirror, we interferometrically detect the differential movement of two mirrors suspended as multiple-stage pendulums. We present the set-up of this experiment and the current sensitivity, and also the different steps that we took in the past to increase the sensitivity, which include an auto alignment of the laser beam into the resonator eigenmode, changes of the seismic isolation system to more damping stages and higher moments of inertia and an intensive noise hunting.

2004-03-07

26

Product moisture after the centrifugation of coarse coal  

Energy Technology Data Exchange (ETDEWEB)

The presence of water in export coals increases transport and handling costs. Coarse (+0.5 mm) coal constitutes the majority of the product, and small changes in its final moisture content will have a significant effect on overall product moisture. An on-line moisture monitor was installed on a product belt immediately after a coarse coal centrifuge to continuously measure the moisture content of the coal from a single centrifuge. Basic studies were also conducted with a laboratory centrifuge specifically designed to characterize various coarse coal samples in terms of their water retention capacity. The moisture of the coarse coal (typically 6 to 9%) was found to vary by at least 1% at a particular plant, and by a number of percentage points between plants. An empirical model has been developed which can explain about 80% of the moisture variation from the 25 samples investigated. The rank of the coals ranged from 0.7 to ...

1998-12-31

27

Radionuclide adsorption characteristics around coastal water  

Energy Technology Data Exchange (ETDEWEB)

The adsorption capacity of radionuclides onto suspended sediment was experimented on each of the coastal seawater sampled around the Kori and the Wolsung nuclear power plant. During the experiment the quantity and size fraction of suspended sediment were adjusted and the seawater and sediment chemistry is approximated to the expected field condition. Because the sorption capacity depends on the specific minerals, ocean chemistry and radionuclide involved, it is necessary to analyze sediment mineralogy. Clay mineral is dominant in seabed mineral and suspended sediment as the result of x-ray diffraction. Radionuclide sorbed to silty-clay mineral can be rather transported to ocean than scavenged to seabed because of low quantity and fine grained suspended sediment in the coast around the Kori and the Wolsung. The result of adsorption examinations shows that {sup 139}Ce and {sup 51}Cr and {sup 110m}Ag are ...

1999-07-01

28

Radionuclide adsorption characteristics around coastal water  

International Nuclear Information System (INIS)

The adsorption capacity of radionuclides onto suspended sediment was experimented on each of the coastal seawater sampled around the Kori and the Wolsung nuclear power plant. During the experiment the quantity and size fraction of suspended sediment were adjusted and the seawater and sediment chemistry is approximated to the expected field condition. Because the sorption capacity depends on the specific minerals, ocean chemistry and radionuclide involved, it is necessary to analyze sediment mineralogy. Clay mineral is dominant in seabed mineral and suspended sediment as the result of x-ray diffraction. Radionuclide sorbed to silty-clay mineral can be rather transported to ocean than scavenged to seabed because of low quantity and fine grained suspended sediment in the coast around the Kori and the Wolsung. The result of adsorption examinations shows that "1"3"9Ce and "5"1Cr and "1"1"0"mAg are strongly ...

1999-11-04

29

GPM on The High Capapcity Centrifuge  

National Aeronautics and Space Administration (NASA)

GPM moves from the clean room to the test chamber on a dolly without wheels. Compressed air is pumped out under airpads that float the Spacecraft on a bed of air. nThe wind generated when the centrifuge moves at its maximum speed are more than 200 mph - that's tornado speed. But since they move with the centrifuge the satellites tested only feel 20 mph winds. nLeaning outward at 45 degrees for one test orientation, GPM comes within 28 inches of the wall. When lifted onto the platform it cleared the ceiling by only five inches. nNatural audio only. nVideo Credit: Brooke Harris n

2011-10-19

30

Evaluation of HL 20 Roller Pump and Rotaflow Centrifugal Pump on Perfusion Quality and Gaseous Microemboli Delivery  

British Library Electronic Table of Contents (United Kingdom)

Abstract The purpose of this study was to compare the HL 20 roller pump (Jostra USA, Austin, TX, USA) and Rotaflow centrifugal pump (Jostra USA) on hemodynamic energy production and gaseous microemboli (GME) delivery in a simulated neonatal cardiopulmonary bypass (CPB) circuit under nonpulsatile perfusion. This study employed a simulated model of the pediatric CPB including a Jostra HL 20 heart lung machine (or a Rotaflow centrifugal pump), a Capiox BabyRX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Capiox pediatric arterial filter (Terumo Corporation), and inch tubing. The total volume of the experimental system was 700 mL (500 mL for the circuit and 200 mL for the pseudo neonatal patient). The hematocrit was maintained at 30% using human blood. At the beginning of each trial, a 5 ...

2010-01-01

32

p-Nonyl-phenol: an estrogenic xenobiotic released from "modified" polystyrene.  

UK PubMed Central (United Kingdom)

Alkylphenols are widely used as plastic additives and surfactants. We report the identification of an alkylphenol, nonylphenol, as an estrogenic substance released from plastic centrifuge tubes. This...Full Text Available

1991-05-01

33

Neuronal regulation of cochlear blood flow in the guinea-pig.  

UK PubMed Central (United Kingdom)

1. Previous studies have shown that electrical stimulation (ES) of the guinea-pig cochlea causes a neurally mediated increase in cochlear blood flow (CBF). It is known that the centrifugal neuronal...Full Text Available

1994-11-01

34

Interaction of the New Ketolide ABT-773 (Cethromycin) with Human Polymorphonuclear Neutrophils and the Phagocytic Cell Line PLB-985 In Vitro  

UK PubMed Central (United Kingdom)

A classical velocity centrifugation technique was used to study the in vitro uptake of the new ketolide ABT-773 by human polymorphonuclear neutrophils (PMNs) and a myelomonoblastic cell line, PLB-985,...Full Text Available

2004-04-01

35

Enzymic Capacities of Purified Cauliflower Bud Plastids for Lipid Synthesis and Carbohydrate Metabolism 1  

UK PubMed Central (United Kingdom)

Isolated cauliflower (Brassica oleracea) bud plastids, purified by isopycnic centrifugation in density gradients of Percoll, were found to be highly intact, to be practically devoid...Full Text Available

1985-10-01

36

Diverse Range of Small Peptides Associated With High-Density Lipoprotein  

UK PubMed Central (United Kingdom)

High-density lipoproteins (HDL) were examined as potential carriers of small peptides in plasma. HDL purified by density gradient centrifugation was delipidated and fractionated by size-exclusion...Full Text Available

2006-02-17

37

A new type of boundary blade for steam turbines  

International Nuclear Information System (INIS)

Long steam turbine blades are always made as massive blades cut from the solid. For a given blade material and given rotational speed of the steam turbine, the maximum permissible blade length depends on a tapering factor which expresses the ratio of the centrifugal force of the real blade, always twisted and tapered, to the centrifugal force of the theoretical cylindrical blade of the same flow cross-section. This factor can be further reduced to a considerable degree, due to a better approximation to the shape having uniform srength, if the blade is constructed as a hollow blade. (orig./LH).

39

Torpor induction in mammals: Recent discoveries fueling new ideas  

UK PubMed Central (United Kingdom)

When faced with a harsh climate or inadequate food, some mammals enter a state of suspended animation known as torpor. A major goal of torpor research is to determine mechanisms that integrate...Full Text Available

2009-12-01

40

Situational Analysis of Household Energy and Biomass Use and Associated Health Burden of Indoor Air Pollution and Mitigation Efforts in Pakistan  

UK PubMed Central (United Kingdom)

Biomass fuel burning leads to high levels of suspended particulate matter and hazardous chemicals in the indoor environment in countries where it is in common use, contributing significantly to indoor...Full Text Available

2010-07-01

41

SeaWiFS Postlaunch Technical Report Series  

Science.gov (United States)

tion and the Copenhagen symposium in many regards heralded the birth of modern marine bio-optics and the .... given to conducting a pigment intercomparison based on .... assignment of personnel and equipment, so the Hout Bay deployments were suspended. ...... submarine light field. Upwelling radiance is measured at ...

42

Photocatalytic hydrogen production from solutions of sulfite using platinized cadmium sulfide powder  

Energy Technology Data Exchange (ETDEWEB)

Platinized cadmium sulfide powder suspended in a solution of sodium sulfite produces hydrogen efficiently by visible light. Sulfite ions are oxidized to sulfate and dithionate ions. 4 figures.

1983-09-29

43

29 CFR 1926.602 - Material handling equipment.  

Science.gov (United States)

...Pneumatic-tired earth-moving haulage equipment (trucks, scrapers, tractors...Pneumatic-Tired Earthmoving Haulage Equipment. An employer may, of course...pneumatic-tired earthmoving haulage equipment, is suspended pending...

2009-07-01

44

Effects of variable hardness, ph, alkalinity, suspended clay, and humics on the chemical speciation and aquatic toxicity of copper  

Science.gov (United States)

The effects of variable hardness, pH, alkalinity, humics, and suspended clay on the chemical speciation of copper and its toxicity to fathead minnow larvae in Lake Superior water were investigated. Two proposed methods (toxicity factors and chemical speciation) for predicting LC50 values in specific natural waters from laboratory toxicity data and the average site specific values of general water quality parameters were evaluated. The accuracy of the cupric ion-selective electrode in determining CU/sup +2/ activities in ambient and chemically altered Lake Superior water was also determined.

1986-03-01

45

Kootenai River Nutrient Dosing System and N-P Consumption: Year 2008.  

Science.gov (United States)

In early 2006 we designed and built low energy consumption, pump-operated system, for dosing of the liquid nutrient in the summer 2006 season. This operated successfully, and the system was used again during the 2007 and 2008 seasons for dosing. During the early winter period, 2008, laboratory tests were made of the liquid nutrient pump system, and it was noted that small amounts of air were being entrained on the suction side of the pump, during conditions when the inlet pressure was low. It was believed that this was the cause of diurnal fluctuations in the flow supplied, characteristic of the 2007 year flow data. Replacement of '0' rings on the inlet side of the pumps was the solution to this problem, and when tested in the field during the summer season, the flow supplied was found to be stable. A decision was made by the IKERT committee at the meeting of 20th to 21st May 2008 (held in Coeur d'Alene, Idaho) to use an injection flow rate of liquid ...

2009-02-19

46

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

47

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

49

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

50

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

51

Studies on ball screw type damper with centrifugal brakes  

International Nuclear Information System (INIS)

The effects of vibration isolation of the new type of mechanical damper applied to a single-degree-of-freedom system and a simple beam are discussed numerically and experimentally. The damper is composed of a ball screw, a flywheel and centrifugal brakes, and possesses nonlinear characteristics. The Continuous System Simulation Language is used for the digital simulations of the nonlinear vibration systems. The results may be summarized as follows: (1) The damper is effective for suppressing the amplitude of the single-degree-of-freedom system as well as of the beam at the point of attachment of the damper, at the resonances. (2) The damper approaches a snubber for smaller values of lead L of the ball screw (or larger values of moment of inertia J of the flywheel), and acts like a damper whose damping force is proportional to the square of the velocity for larger values of L (or smaller values of J). (author).

1986-01-01

52

Sizing pumps for slurries  

Energy Technology Data Exchange (ETDEWEB)

Slurry characteristics have a significant impact on centrifugal pump performance. For instance, as particle size increases or the percent solids concentration increases, pump head and efficiency decrease. Therefore, before a slurry pump is selected, it is important to define the slurry characteristics as accurately as possible. The effect of the slurry characteristics on the head and efficiency of the centrifugal pump will be emphasized (the effect on flowrate is less significant). The effect of slurry characteristics is more predominant in smaller pumps (with smaller diameter impellers) than in larger pumps. The data and relationship between the various slurry parameters have been developed from correlations and nomographs published by pump vendors from their field data and test results. The information helps to avoid specifying an undersized pump/motor assembly for slurry service.

1996-11-01

53

Method of reducing volume of radioactive liquid waste  

International Nuclear Information System (INIS)

Purpose: To enable the solidification of liquid waste containing radioactive substance in a free shape with large volume reduction ratio without a pulverizing step by producing solute in the liquid waste as a slurry in a predetermined organic solvent and forming it into a cake by mechanical exfoliation. Method: Liquid waste containing suitably concentrated radioactive substances is supplied to a centrifugal thin film evaporator together with an organic agent having a higher boiling point than water and a non aqueous solution to evaporate the water content, the solute in the waste is produced as a slurry in the organic solvent, and removed as cake-state solute slightly residued with the organic solvent by the mechanical exfoliation such as centrifugal exfoliation or settling exfoliation from the slurry-state liquid. Accordingly, it can be increased in size as compared with the powder reduced in volume of the radioactive liquid waste, and can be ...

1981-08-01

54

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

55

Contaminant assimilation in newly created prairie wetlands  

Energy Technology Data Exchange (ETDEWEB)

Increased use of wetlands for habitat and water quality improvement emphasize the need for further study of abiotic-biotic interactions in these systems. This research examined contaminant assimilation within the water column of two newly created Colorado prairie wetlands (RMA3 and RMA4). To examine the influence of abiotic factors (e.g., alkalinity, suspended solids), ten chronic toxicity tests were performed from December 1991 through November 1993. In the first set of tests, Ceriodaphnia dubia were exposed to water from the two wetlands which was spiked with various concentrations of zinc. These tests suggested that water from RMA4 had higher contaminant assimilative capacity than water from RMA3. Preliminary analysis suggested suspended solids, pH, conductivity, and temperature were important factors affecting neonate production by C. dubia when exposed to zinc-spiked wetland water. To test the importance of suspended ...

1994-12-31

56

The Philadelphia Marriott: A convention center flagship hotel  

Energy Technology Data Exchange (ETDEWEB)

This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.

1997-01-01

57

Process for uranium processing  

International Nuclear Information System (INIS)

To the crushed ore leaching is applied. The resulting solid-liquid mixture is fed to a hydro-cyclon grading facility; here the superfine grain is separated before the concentrated mixture can be filtered or centrifuged. The grading is done in several steps. From the liquid, ultimately ridded of the solid, uranium compounds are precipitated and the yellow cake is obtained. (DG).

1984-11-12

58

Impact of repeated two-phase olive mill waste application on phosphorus fractionation in a degraded olive grove soil  

Energy Technology Data Exchange (ETDEWEB)

Loss of organic matter is one of the main forms of soil degradation in Mediterranean agricultural soils, and external sources of organic matter are required to improve soil properties. the two-phase centrifugation system in the olive-oil extraction industry produces a large amount of olive mill waste sludge (TPOMW) which can be used to add organic C to degraded soils. (Author)

2009-07-01

59

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

60

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

61

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

62

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

63

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

65

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

66

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

68

The influence of contrasting suspended particulate matter transport regimes on the bias and precision of flux estimates  

British Library Electronic Table of Contents (United Kingdom)

A large database (507 station-years) of daily suspended particulate matter (SPM) concentration and discharge data from 36 stations on river basins ranging from 600?km2 to 600,000?km2 in size (USA and Europe) was collected to assess the effects of SPM transport regime on bias and imprecision of flux estimates when using infrequent surveys and the discharge-weighted mean concentration method. By extracting individual SPM concentrations and corresponding discharge values from the database, sampling frequencies from 12 to 200 per year were simulated using Monte Carlo techniques. The resulting estimates of yearly SPM fluxes were compared to reference fluxes derived from the complete database. For each station and given frequency, bias was measured by the median of relative errors between estima...

2006-01-01

69

Loading of wellbores with explosives  

Energy Technology Data Exchange (ETDEWEB)

Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube when the latter is raised to the surface is assured by threading the cord through plastic tubing mounted to the wall of the ...

1983-04-26

70

Electrochemical method for the synthesis of silver nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

The article deals with a novel electrochemical method of preparing long-lived silver nanoparticles suspended in aqueous solution as well as silver powders. The method does not involve the use of any chemical stabilising agents. The morphology of the silver nanoparticles obtained was studied using transmission electron microscopy, scanning electron microscopy, atomic force microscopy and dynamic light scattering measurements. Silver nanoparticles suspended in water solution that were produced by the present technique are nearly spherical and their size distribution lies in the range of 2 to 20 nm, the average size being about 7 nm. Silver nanoparticles synthesised by the proposed method were sufficiently stable for more than 7 years even under ambient conditions. Silver crystal growth on the surface of the cathode in the electrochemical process used was shown to result in micron-sized structures consisting of agglomerated silver nanoparticles ...

2009-07-15

71

Atmospheric Gravity Perturbations Measured by Ground-Based Interferometer with Suspended Mirrors  

CERN Document Server

A possibility of geophysical measurements using the large scale laser interferometrical gravitational wave antenna is discussed. An interferometer with suspended mirrors can be used as a gradiometer measuring variations of an angle between gravity force vectors acting on the spatially separated suspensions. We analyze restrictions imposed by the atmospheric noises on feasibility of such measurements. Two models of the atmosphere are invoked: a quiet atmosphere with a hydrostatic coupling of pressure and density and a dynamic model of moving region of the density anomaly (cyclone). Both models lead to similar conclusions up to numerical factors. Besides the hydrostatic approximation, we use a model of turbulent atmosphere with the pressure fluctuation spectrum f^{-7/3} to explore the Newtonian noise in a higher frequency domain (up to 10 Hz) predicting the gravitational noise background for modern gravitational wave detectors. Our estimates show that this could pose ...

2003-01-01

72

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...

2009-03-01

73

Statistical support document for proposed effluent limitations guidelines and standards for the pulp, paper, and paperboard. Point source category  

Energy Technology Data Exchange (ETDEWEB)

The document describes the statistical analyses of data on pollutant loadings in effluent wastestreams from pulp, paper, and paperboard facilities. Included are the analyses that support the revised subcategorization and proposed effluent limitations for biochemical oxygen demand and total suspended solids based upon the best practicable control technology currently available.

1993-11-01

74

Production of high porous fibrous materials on the base of VT6 titanium alloy long-dimension fibers  

International Nuclear Information System (INIS)

VT6 titanium alloy long-range fibers have been extracted from the suspended melt drop with the following high-rate solidification. Formation of the structure of fibrous porous material prepared from these fibers has been studied. 7 refs.; 5 figs.; 2 tabs.

75

Morphological Instabilities in a growing Yeast Colony Experiment and Theory  

CERN Document Server

We study the growth of colonies of the yeast Pichia membranaefaciens on agarose film. The growth conditions are controlled in a setup where nutrients are supplied through an agarose film suspended over a solution of nutrients. As the thickness of the agarose film is varied, the morphology of the front of the colony changes. The growth of the front is modeled by coupling it to a diffusive field of inhibitory metabolites. Qualitative agreement with experiments suggests that such a coupling is responsible for the observed instability of the front.

1997-01-01

76

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...

1981-11-11

78

Magnetic braking of the rotation of molecular cloud cores  

International Nuclear Information System (INIS)

We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).

79

LHC magnet alignment  

CERN Document Server

Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.

2007-01-01

80

Density separation of materials by using magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...

1980-03-01

81

Protein binding assay for hyaluronate  

Energy Technology Data Exchange (ETDEWEB)

A relatively quick and simple assay for hyaluronate was developed using the specific binding protein, hyaluronectin. The hyaluronectin was obtained by homogenizing the brains of Sprague-Dawley rats, and then centrifuging the homogenate. The resulting supernatant was used as a source of crude hyaluronectin. In the binding assay, the hyaluronectin was mixed with (/sup 3/H)hyaluronate, followed by an equal volume of saturated (NH/sub 4/)/sub 2/SO/sub 4/, which precipitated the hyaluronectin and any (/sup 3/H)hyaluronate associated with it, but left free (/sup 3/H)hyaluronate in solution. The mixture was then centrifuged, and the amount of bound (/sup 3/H)hyaluronate in the precipitate was determined. Using this assay, the authors found that hyaluronectin specifically bound hyaluronate, since other glycosaminoglycans failed to compete for the binding protein. In addition, the interaction between hyaluronectin and hyaluronate was of relatively high ...

1986-11-01

82

Development of engineering technology basis for industrialization of pyrometallurgical reprocessing  

International Nuclear Information System (INIS)

Development of the engineering technology basis of pyrometallurgical reprocessing is a key issue for industrialization. For development of the transport technologies of molten salt and liquid cadmium at around 500 deg. C, a salt transport test rig and a metal transport test rig were installed in Ar glove box. Function of centrifugal pump and 1/2'' declined tubing were confirmed with LiCl- KCl molten salt. The transport behavior of molten salt was found to follow that of water. Function of centrifugal pump, vacuum sucking and 1/2'' declined tubing were confirmed with liquid Cd. With employing the transport technologies, industrialization applicable electro-refiner was newly designed and engineering-scale model was fabricated in Ar glove box. The electro-refiner has semi-continuous liquid Cd cathode instead of conventional one used in small-scale tests. With using actinide-simulating elements, demonstration of industrial-scale throughput will be ...

2007-09-09

83

Cd speciation in biomass fly ash particles after size separation by centrifugal SPLITT  

Energy Technology Data Exchange (ETDEWEB)

The finest particle size fractions ({le} 25 {mu}m) in four fly ash samples from fluidised bed combustion of three biomass based fuels and a municipal solid waste fuel were size separated using a centrifugal SPLITT fractionation cell. The ashes were separated into different size fractions and the cadmium concentration, partition and speciation in each separated fraction were then investigated in relation to their possible leaching. The fractionation was evaluated by environmental scanning electron microscopy, which also provided indications of the associations between Cd and other main elements on the particles through the use of X-ray fluorescence mapping. The total concentration of Cd in each fraction was determined by AAS analysis which showed different dependence on the ash particle size in the case of biomass or waste fuels. In addition, the speciation of Cd in each fraction, investigated by sequential chemical extractions and X-ray powder diffraction analysis, ...

2002-08-01

84

Physical and optical properties of rare earth cobalt magnets  

Energy Technology Data Exchange (ETDEWEB)

Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.

1980-08-01

90

METHOD OF FORMING THIN MAGNETIC FILM  

J-STORE (Japan)

Full Text Available

2007-10-04

96

Localization of highly repetitive, species-specific EcoRI elements from 'Lupinus luteus' L  

International Nuclear Information System (INIS)

Using Southern, dot-blot and 'in situ' hybridization, molecular and cytological localization of repetitive 'Lupinus lueteus' DNA sequence was shown. Under CsCl gradient centrifugation conditions CG-rich satellite fraction appeared. Dot-blot hybridization clearly indicated that 1070bp repetitive element being a member of previously described EcoRI fragments family appeared only in the main band. The use of that DNA fragment as an 'in situ' hybridization signal in the euchromatin area. (author). 26 refs, 3 figs.

97

Hazard Evaluation for the Saltwell Chempump and a Saltwell Centrifugal Pump Design using Service Water for Lubrication and Cooling  

Energy Technology Data Exchange (ETDEWEB)

This report documents results of a preliminary hazard analysis (PHA) covering the existing Crane Chempump and the new salt well pumping design. Three hazardous conditions were identified for the Chempump and ten hazardous conditions were identified for the new salt well pump design. This report also presents the results of the control decision/allocation process. A backflow preventer and associated limiting condition for operation were assigned to one hazardous condition with the new design.

2000-11-16

98

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Science.gov (United States)

The dynamic response characteristics of the VAWT rotor are important factors governing the safety and fatigue life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. This paper will describe and discuss the primary tools now in use at Sandia National Laboratories for rotor analysis. These tools include a lumped springmass model (VAWTDYN) and also finite-element based approaches. The discussion will center on the accuracy and completeness of current capabilities and plans for future research.

1981-01-01

99

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Science.gov (United States)

The dynamic response characteristics of the vertical axis wind turbine (VAWT) rotor are important factors governing the safety and fatigue life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and Coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. The primary tools now in use for rotor analysis are described and discussed. These tools include a lumped spring mass model (VAWTDYN) and also finite-element based approaches. The accuracy and completeness of current capabilities are also discussed.

1981-05-01

100

Development of a solvent extraction process for cesium removal from SRS tank waste  

International Nuclear Information System (INIS)

An alkaline-side solvent extraction process was developed for cesium removal from Savannah River Site (SRS) tank waste. The process was invented at Oak Ridge National Laboratory and developed and tested at Argonne National Laboratory using singlestage and multistage tests in a laboratory-scale centrifugal contactor. The dispersion number, hydraulic performance, stage efficiency, and general operability of the process flowsheet were determined. Based on these tests, further solvent development work was done. The final solvent formulation appears to be an excellent candidate for removing cesium from SRS tank waste.

2001-06-30

101

Depleted zinc: Properties, application, production  

Energy Technology Data Exchange (ETDEWEB)

The addition of ZnO, depleted in the Zn-64 isotope, to the water of boiling water nuclear reactors lessens the accumulation of Co-60 on the reactor interior surfaces, reduces radioactive wastes and increases the reactor service-life because of the inhibitory action of zinc on inter-granular stress corrosion cracking. To the same effect depleted zinc in the form of acetate dihydrate is used in pressurized water reactors. Gas centrifuge isotope separation method is applied for production of depleted zinc on the industrial scale. More than 20 years of depleted zinc application history demonstrates its benefits for reduction of NPP personnel radiation exposure and combating construction materials corrosion.

2009-07-15

102

6. Sample preparation for determining pollutants in components of the environment  

International Nuclear Information System (INIS)

Examples are given of reference materials for radionuclide X-ray fluorescence analysis (RXFA) of the environment processed by the National Bureau of Standards and the IAEA. Methods are described used for preparing standard materials for RXFA. For determining air pollutants the sample is prepared by dry or wet mineralization. Water samples have to be preserved prior to analysis. Insoluble components are separated by filtration or centrifugation. Biological materials must be dehydrated and homogenized. Samples of soil, sludges, sediments and solid wastes will sometimes have to be converted into a solution in some cases a leachate will have to be obtained. (ES).

1983-12-01

103

NASA TECH BRIEF  

Science.gov (United States)

Magnetic Forming Studies. The use of transient high magnetic-field devices has made possible the generation of very large accurately ...

105

Magnetic properties of single crystalline RE_2PdSi_3 intermetallic compounds  

International Nuclear Information System (INIS)

... susceptibility magnetization magnetoresistance monocrystals order-disorder

106

Finite Element Analysis of Magnetoelastic Plate Problems.  

Science.gov (United States)

... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...

1981-08-01

107

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

108

An investigation of the decoupling effects in a magnetic forming beryllium coil assembly.  

Science.gov (United States)

Decoupling force exerted by magnetic forming Be coil assembly on metallic plate during forming

1968-01-01

110

Progress of magnetic-suspension systems and magnetic bearings in the USSR  

International Nuclear Information System (INIS)

This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.

1992-05-01

111

International Symposium on Magnetic Suspension Technology. Part 2  

International Nuclear Information System (INIS)

In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.

1991-08-19

112

Design of a magnetic braking system  

International Nuclear Information System (INIS)

A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted magnetic flux is within ...

2006-09-01

113

Identifying primary stressors impacting macroinvertebrates in the Salinas River (California, USA): Relative effects of pesticides and suspended particles  

International Nuclear Information System (INIS)

Laboratory dose-response experiments with organophosphate and pyrethroid pesticides, and dose-response experiments with increasing particle loads were used to determine which of these stressors were likely responsible for the toxicity and macroinvertebrate impacts previously observed in the Salinas River. Experiments were conducted with the amphipod Hyalella azteca, the baetid mayfly Procloeon sp., and the midge Chironomus dilutus (Shobanov, formerly Chironomus tentans). The results indicate the primary stressor impacting H. azteca was pesticides, including chlorpyrifos and permethrin. The mayfly Procloeon sp. was sensitive to chlorpyrifos and permethrin within the range of concentrations of these pesticides measured in the river. Chironomus dilutus were sensitive to chlorpyrifos within the ranges of concentrations measured in the river. None of the species tested were affected by turbidity as high as 1000 NTUs. The current study shows that pesticides are more important acute stressors ...

2006-06-01

114

Preparation of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is fabrication and characterization of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS). The silver metal electrodes under the electrical discharge will melt and evaporate rapidly and condense to form the nanoparticles in the lower temperature dielectric liquid and produce the suspended nanoparticle. The results showed that the spherical nanosilver particle formed in the ethylene glycol and the mean particle size is about 12.5 nm. The prepared silver nanofluid was irradiated under the 410 nm visible light, electrons could be excited from the valence band to the conduction band. The silver nanofluid more closely resembles Newtonian fluids.

2007-05-31

115

Novel approach towards improving decontamination factor (DF) in treatment of low level radioactive waste  

International Nuclear Information System (INIS)

The use of finely powdered ion exchange resins improve loading of specific ion exchange materials with better performance but as such these materials are not suitable for column operation. However, by proper selection of ion exchange support medium, it is possible to get better product. The radioactive solution can be treated by suspending this material, stirring and allowing to settle. The present method gives DF in the range of 70 - 80 even after repeated use as compared to DF in the range of 5 to 10 by single conventional chemical treatment process. (author)

2001-02-07

116

Landslides affecting sedimentary characteristics of reservoir basin  

British Library Electronic Table of Contents (United Kingdom)

Typhoons Aere (2004) and Matsa (2005) caused high nephelometric turbidity in the Shihmen reservoir in northern Taiwan, jeopardizing the operation of the reservoir for several days, and ultimately impacting the living conditions and economy of the downstream residents. The torrential rains caused landslides and debris flows in upland areas, and flowed into riverbeds, likely contributing significantly to the suspended sediment yields in the reservoir. This investigation elucidates how upland landslides affect sediment attributes in the reservoir basin. Study methods including field observations, spatial analysis in GIS and aerial photo interpretation are adopted to trace the sediment sources and contributing factors to the landslide. Torrential rains induced landslides and debris-flows uplan...

2010-01-01

117

Galvanic element with suspended electrode. Galvanisches Element mit suspendierter Elektrode  

Energy Technology Data Exchange (ETDEWEB)

A zinc/air battery is claimed whose performance is improved by omitting separating elements such as diaphragms etc. The cathode and anode spaces are separated by a collector with holes big enough to permit the electrons to pass freely while restraining the anode material. Further, the active material consists of a spherical care of inert material with a zinc coating. Under the zinc coating, the spherical particles have another thin coating of an electropositive material, e.g. nickel. The cell also contains means for circulating the anode suspension.

1984-08-09

118

Conceptual design of the ATLAS EM muon chamber support structures  

CERN Document Server

The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.

1998-01-01

119

A small particle selective emitter for thermophotovoltaic energy conversion  

Energy Technology Data Exchange (ETDEWEB)

This paper presents an analysis of the performance of a selective emitter using small particles of rare earth compounds stable at high temperatures in a low emittance inert gas stream. An expression for the spectral emissive power excluding radiation scattering was derived to include the radiation in the emission band, produced by electronic transitions of the rare earth ion, and the continuum radiation outside the emission band produced by the rare earth host. Preliminary results suggest that a selective emitter based on suspended rare earth oxide particles will have high efficiency and merits further experimental investigation. {copyright} {ital 1996 American Institute of Physics.}

1996-02-01

120

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

121

Magnetic fluctuation measurement in Sino United Spherical Tokamak plasma  

International Nuclear Information System (INIS)

To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)

2007-07-01

122

Renovation of Isogo thermal power plant of Electric Power Development Co. with new and old systems near to each other; Dengen Kaihatsu (kabu) Isogo karyoku hatsudensho koshin koji shinsetsu hosui kanro to kisetsu hatsudensho OF cable no kinsetsu seko  

Energy Technology Data Exchange (ETDEWEB)

This is a build-and-scrap-and-build job, in which a new No. 1 generator is constructed while the existing plant stays in operation in the same site. Since interference between the new and the existing systems are unavoidable in such work, protection is sufficiently provided and measurements are frequently performed when the work comes to involve important structures positioned close to each other, such as the existing No. 1 and No. 2 OF (oil-filled) cables transmitting power from the existing power plant to Minami-Yokohama Substation of Tokyo Electric Power Co., Ltd., and the newly planned discharge channel or the existing covered sewerage and the newly planned discharge outlet. Now that the newly planned discharge channel intercepts the OF cables at three places and is installed to pass under the existing cable duct, it once happened that the duct supporting piles were severed for the cables to suspend in the air though temporarily. During this episode, the cables ...

1998-09-05

123

On the properties of plasma crystals  

Energy Technology Data Exchange (ETDEWEB)

When a plasma becomes contaminated by foreign particles, generically referred to as dust, the result is called a dusty plasma. At the present time there is a great deal of interest in dusty plasmas because of their roles in terrestrial and extra-terrestrial processes - semiconductor processing, high temperature fusion experiments, stellar formation and the rings of Saturn. This thesis is concerned with the role of dust in processing type plasmas. In the following experiments, artificial dust is introduced into a parallel electrode plasma chamber. Ions and electrons in the plasma charge the dust particles and they become suspended in the plasma due to the balancing of electric and gravitational forces. By illuminating the suspended dust with laser light and using an extremely high speed camera fitted with a macro lens to look at the scattered light, the dust particles are observed directly. Specially written computer software is then able to ...

1999-07-01

124

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...

1999-04-01

125

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

126

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

127

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We ...

2005-04-01

128

Magnetic properties of materials  

Energy Technology Data Exchange (ETDEWEB)

A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)

2000-08-15

129

Magnetic flocculation and filtration  

Energy Technology Data Exchange (ETDEWEB)

A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.

1996-10-01

130

The effective longitudinal dielectric constant for plasmas in inhomogeneous magnetic fields  

Scientific Electronic Library Online (English)

Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.

2004-09-01

131

Magnetic mirror fusion systems: Characteristics and distinctive features  

Energy Technology Data Exchange (ETDEWEB)

A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.

1987-08-10

132

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

133

Magnetic excitations studied with time-of-flight spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.

1996-11-01

134

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

135

Active magnetic regenerator  

Energy Technology Data Exchange (ETDEWEB)

The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.

1982-01-01

136

Nanocrystalline permanent magnets with enhanced properties  

International Nuclear Information System (INIS)

Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

2001-09-23

137

Viscosity of the Earth's inner core: Constraints from nutation observations  

British Library Electronic Table of Contents (United Kingdom)

The gravitational torque applied on the Earth by the other celestial bodies generates periodic variations in the orientation of the Earth's rotation axis in space which are called nutations. Observations of Earth's nutations allow for insights into the physical properties of the inner core because of the presence of a normal mode, the Free Inner Core Nutation (FICN), which is characterized by a tilt of the inner core figure and rotation axes with respect to the mantle and outer core. The frequency of the FICN is controlled by the strength of the mechanical coupling acting at the inner core boundary (ICB) and by the ability of the inner core to deform under the action of centrifugal and gravitational forces. Attenuation of the FICN reflects energy dissipated by electromagnetic (EM) and visc...

2011-01-01

138

Usefulness of routine laboratory parameters in the decision to treat refractory cardiac arrest with extracorporeal life support  

British Library Electronic Table of Contents (United Kingdom)

Aim: To evaluate the usefulness of routine laboratory parameters in the decision to treat refractory cardiac arrest patients with extracorporeal life support (ECLS). Methods: Sixty-six adults with witnessed cardiac arrest of cardiac origin unrelated to poisoning or hypothermia undergoing cardiopulmonary resuscitation without return of spontaneous circulation (duration: 155min [120-180], median, [25-75%-percentiles]) were included in a prospective cohort-study. ECLS was implemented under cardiac massage, using a centrifugal pump connected to a hollow-fiber membrane-oxygenator, aiming to maintain ECLS flow >=2.5l/min and mean arterial pressure >=60mmHg. Results: Forty-seven of 66 patients died within 24h from multiorgan failure and massive capillary leak. Of 19/66 patients who survived >=24h...

2011-01-01

139

The control of neptunium and plutonium in single cycle solvent extraction flowsheets for advanced fuel cycles  

International Nuclear Information System (INIS)

Simple hydroxamic acids are shown to be useful reagents for the separation of Np and Pu from U within simplified, single cycle Purex flowsheets. They are compatible with the use of centrifugal contactors and laboratory scale flowsheet trials with aceto-hydroxamic acid have demonstrated high actinide recoveries and decontamination factors on products for active feeds of up to 40 wt.% Pu. They therefore show many ideal characteristics for Pu and Np recovery within flowsheet options for actinide recovery in advanced fuel cycles. Furthermore, in order to optimise the routing of Np with the Pu product in advanced flowsheets, additional studies of Np extraction in the primary co-decontamination contactor, prior to U/Pu partition, have been undertaken, combining experiment, modelling and flowsheet tests. (author)

2005-10-09

140

Start safety apparatus for internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A start safety apparatus of an engine adapted for a multipurpose power tool is described which consists of: an engine, an exciter coil generating alternate electromotive force in synchronism with rotation of the engine; an ignition coil having primary and secondary windings; a spark plug connected to the secondary winding of the ignition coil; a capacitor connected to the primary winding of the ignition coil the capacitor being charged with a positive half-cycle of the electromotive force; ignition timing control means for controlling discharge of the capacitor; a throttle control latch for setting a throttle valve of the engine in a predetermined throttle angle; a tool driven by the engine; and a centrifugal clutch transferring engine power to the tool when an engine speed exceeds a clutch-in speed.

1986-09-09

141

Silver removal process development for the MEO cleanout  

Energy Technology Data Exchange (ETDEWEB)

The Mediated Electrochemical Oxidation (MEO) system is an aqueous process which treats low-level mixed wastes by oxidizing the organic components of he waste into carbon dioxide and water. As MEO system continues to run, dissolved ash and radionuclides slowly accumulate in the anolyte and must be removed to maintain process efficiency. At such time, all of the anolyte is pumped into a still feed tank, and the silver ions need to be removed before sending the solution to a thin-film evaporator for further concentration. The efficiency of removing silver ions in the solution needs to be high enough such that the residual silver sent to Final Forms would be less than 1% wt. The purpose of this work is to develop an efficient process to remove silver ions during the MEO cleanout and to demonstrate the capability of centrifugation for separating small silver chloride particles from the solution. This development work includes lab scale experiments and bench scale tests. ...

1996-02-01

142

Impact of Tubing Length on Hemodynamics in a Simulated Neonatal Extracorporeal Life Support Circuit  

British Library Electronic Table of Contents (United Kingdom)

Abstract During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8 Fr Biomedicus arterial and a 10 Fr Biomedicus venous cannula were connected to the pseudopatient. One fourth inch tubing was used for both the arterial and the venous line. A ...

2010-01-01

143

Erosion testing of CRC 262; Erosionsprovning av CRC 262  

Energy Technology Data Exchange (ETDEWEB)

Solid particle erosion (SPE) testing was made on Sandvik CRC 262 with different heat treatments and on the steels Type 321 and 15Mo3. The Studsvik Erofuge, a centrifugal erosion tester, was used and the testing was performed in air at room temperature. Alumina and olivine sand particles were used at a particle velocity of 60 m/s and at impingement angles of 60 degrees and 90 degrees. Differences in erosion resistance were obtained for CRC 262 depending on the heat treatment. Olivine sand resulted in lower erosion of CRC 262 than when using alumina. The particle type dependence is low for the other materials, Tp 321 and 15Mo3. CRC 262 has a slightly higher erosion resistance than Tp 321 and 15Mo3 and the differences are most pronounced when using olivine sand

1993-09-01

144

Effect of processing of dates into date juice concentrate and appraisal of its quality characteristics  

British Library Electronic Table of Contents (United Kingdom)

Date palm (Phoenix dactylifera) is widely cultivated in Kutch district of Gujarat and the fruits are harvested at immature stage before the onset of monsoon to prevent spoilage. The immature date fruits with less commercial value were used for processing into date juice concentrate. Immature dates were crushed and treated with 0.1% pectinase enzyme for 120 min to obtain maximum juice. Date juice was found to be rich in reducing sugars (16.1%) and total sugars (18.3%). Juice was pasteurized at 85?C to inactivate the enzyme, cooled and centrifuged at 3000 rpm to get clear juice. The juice was concentrated in a thin film evaporator to a total soluble solids (TSS) of 76?Brix in 2 passes. Chemical composition of date juice during different stages of concentration was determined. Date juice conc...

2010-01-01

145

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Energy Technology Data Exchange (ETDEWEB)

The dynamic response characteristics of the VAWT rotor are important factors governing the safety and fatique life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and Coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. This paper will describe and discuss the primary tools now in use at Sandia National Laboratories for rotor analysis. These tools include a lumped spring-mass model (VAWTDYN) and also finite-element based approaches. The discussion will center on the accuracy and completeness of current capabilities and plans for future research. As this paper is meant primarily to provide an overview, much of the detail is omitted and will be presented in a follow-on report.

1981-05-01

146

Development of Lead-Free Copper Alloy-Graphite Castings  

Energy Technology Data Exchange (ETDEWEB)

In this project, graphite is used as a substitute for lead in order to maintain the machinability of plumbing components at the level of leaded brass. Graphite dispersed in Cu alloy was observed to impart good machinability and reduce the sizes of chips during machining of plumbing components in a manner similar to lead. Copper alloys containing dispersed graphite particles could be successfully cast in several plumbing fixtures which exhibited acceptable corrosion rate, solderability, platability, and pressure tightness. The power consumption for machining of composites was also lower than that of the matrix alloy. In addition, centrifugally cast copper alloy cylinders containing graphite particles were successfully made. These cylinders can therefore be used for bearing applications, as substitutes for lead-containing copper alloys. The results indicate that copper graphite alloys developed under this DOE project have a great potential to substitute for lead ...

1999-10-01

147

Characterization of enzyme-deproteinized skim rubber  

British Library Electronic Table of Contents (United Kingdom)

Skim natural rubber latex is a protein-rich byproduct obtained during the centrifugal concentration of natural rubber latex. Skim latex has a very low dry rubber content (4-8%), and the rubber particles are smaller in size. It has a higher proportion of nonrubber solids, which are mostly proteinaceous in nature. It is difficult to coagulate, and it takes more processing time. The proteins in skim latex can be decomposed by proteolytic enzymes. This article discusses the use of stabilized liquid papain from the papaya plant (Carica papaya) for deproteinization followed by creaming for quick and easy coagulation of skim latex. The technological properties and aging characteristics of the deproteinized skim rubber are compared with those of conventionally prepared skim rubber and block rubber...

2009-01-01

148

Untitled - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...

149

Symptoms of the musculoskeletal system and exposure to magnetic fields in an aluminium plant.  

UK PubMed Central (United Kingdom)

OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available

1995-08-01

150

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.

1985-08-01

151

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be ...

2009-10-19

152

Possible observation of the coexistence of superconductivity and long-range magnetic order in NdRh_4B_4  

International Nuclear Information System (INIS)

The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).

1979-01-01

153

PLASMA JET WELDING, COATING, AND CUTTING: AN ...  

Science.gov (United States)

... 31. New electric forming methods offer potentials for light metals; magnetic forming and plasma forming. ... 3, 25 Magnetic Forming ..... ...

1963-02-01

154

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

Energy Technology Data Exchange (ETDEWEB)

Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-15

155

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

International Nuclear Information System (INIS)

Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-01

156

Mechanism of viscosity effect on magnetic island rotation  

Energy Technology Data Exchange (ETDEWEB)

It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)

2000-04-01

157

Magnetic Properties of Ni Nanoparticles Embedded in ...  

Science.gov (United States)

... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...

2011-05-14

158

Localization of small magnets against a noisy background  

Science.gov (United States)

Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.

2001-05-01

159

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

160

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...

2005-02-01

161
162

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI ...

2009-05-15

163

Evaluation of Commercial Magnetic Descalers.  

Science.gov (United States)

With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...

1984-01-01

164

Develop Magnetic Coil Design and Manufacturing Capability.  

Science.gov (United States)

... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...

1974-11-01

166

CONTRACT: NAS 8-11811 DESIGN, DEVELOPMENT, MANUFACTURE, AND ...  

Science.gov (United States)

has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magnetic coil is placed over a thin aluminum ...

167

Application of the grazing angle polarized neutron reflectometry to study the magnetism in thin films and stratified media  

Energy Technology Data Exchange (ETDEWEB)

From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...

1992-12-01

168

Anisotropic forming of magnetic powders mixed with ultraviolet resin; Shigaisen koka jushi wo mochiita jisei funmatsu no haiko seikei  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...

1999-01-15

169

An Advance in Superconducting Magnet Technology Opens the Door...  

Science.gov (United States)

magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...

2011-08-20

170

Magnetic properties of a SmNiSn single crystal  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the ...

2003-04-01

171

Development of magnetic drive packless valves for commercial purpose  

Energy Technology Data Exchange (ETDEWEB)

A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting ...

1995-09-01

172

Challenges in fabrication of 180deg magnet chamber  

International Nuclear Information System (INIS)

180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector ...

2006-11-01

173

AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab  

Energy Technology Data Exchange (ETDEWEB)

Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar ...

1992-09-01

174

Apparent slip at the surface of a small rotating sphere in a dilute quiescent suspension  

Energy Technology Data Exchange (ETDEWEB)

We consider the case of a test sphere (ball) of radius a{sub 1} rotating at constant angular velocity {omega} in an otherwise quiescent unbounded suspension of uniformly sized spheres of radii a{sub 2} dispersed in a Newtonian fluid of viscosity {mu}. To the first order in the volume fraction c of suspended spheres it is shown that when the ball is small compared with the suspended spheres the suspension does not behave as regards the hydrodynamic torque L exerted on the ball like a homogeneous Newtonian fluid characterized by the usual Einstein viscosity coefficient {mu}{sub s}={mu}(1+5/2c). Explicitly, the torque on the rotating sphere does not obey Kirchoff{close_quote}s law, L=8{pi}{mu}{sub s}a{sub 1}{sup 3}{omega} for no slip. Rather, a modified form of Kirchoff{close_quote}s law is obtained in which the Einstein coefficient of 5/2 is multiplied by a coefficient which is less than unity in magnitude and is functionally dependent only upon ...

1998-03-01

175

Effects of different concentrations of Maytenus ilicifolia (Espinheira Santa) on labelling of red blood cells and blood proteins with Technetium-99m  

International Nuclear Information System (INIS)

The use of natural products in all over the world has been increased in Brazil as well as in other countries. Maytenus ilicifolia is commonly used in popular medicine. The labeling of red blood cells (RBC) with technetium-99m ("9"9"m Tc) have been for many studies in nuclear medicine. This labeling procedure depends on a reducing agent and stannous chloride is normally used. Here, we investigate if the extract of Maytenus ilicifolia is capable to alter the labeling of RBC and blood proteins with "9"9"m Tc. Blood samples were incubated with Maytenus ilicifolia. Stannous chloride solution and Tc-99m were. Blood was centrifuged and plasma (P) and blood cells (C) were isolated. Samples of P or C were precipitated with trichloroacetic acid, centrifuged and IF and IF were separated. The percentage of radioactivity (% ATI) in C, IF-P and IF-C was calculated. The %ATI in decreased in C from 93.6#+-#2.3 to 29.0#+-#2.7, on FI-P from 77.6#+-#1.2 to 7.5 ...

176

Distribution of lead in milk and the fate of milk lead in the gastrointestinal tract of suckling rats  

Energy Technology Data Exchange (ETDEWEB)

Milk can be a significant source of lead (Pb) for young mammals, including humans. Certain essential trace elements have previously been shown to be specifically associated with particular milk components and such associations often increase bioavailability. Thus, the first goal of this study was to determine the distribution of Pb in cream, casein, and whey fractions of various milks under various conditions using /sup 203/Pb as a tracer. In rat milk almost 90% of the Pb was found to be associated with the casein micelles, regardless of: 1) whether the milk was labeled in vivo or in vitro; b) whether the milk was fresh or frozen; and c) the added concentration of Pb. The remainder of the Pb was approximately equally distributed between cream and whey. A virtually identical pattern of Pb distribution was observed with bovine milk. Pb added to infant formula also associated predominantly with casein micelles, although the Pb content of this fraction was significantly less than with rat ...

1988-01-01

177

Development of lead-free copper alloy graphite castings. Annual report, January--December 1995  

Energy Technology Data Exchange (ETDEWEB)

The distribution of graphite particles in graphite containing copper alloy was further improved very significantly using several procedures and technological modifications. The developed techniques attacked the graphite distribution problem in two ways. Realizing that clustering of very fine (5um) graphite particles is one of the two major problems, a pretreatment process has been developed using aluminum powders to deagglomerate graphite particles. Along with this, a two-stage stirring technique was used to first incorporate and then to distribute uniformly the deagglomerated particles in the melt. During this year, based on these developments, several components were cast to evaluate the castability of Cu alloy-graphite melts. In addition, machinability tests were done to clearly established that addition of graphite particles improve the machinability of copper MMC alloys over and above that of monolithic copper alloys. The results show that the machining chip sizes and cutting ...

1996-10-01

180

The Effect of Static Magnetic Forces on Water Contents and Photosynthetic Pigments in Sweet Basil Ocimum basilicum L. (Lamiaceae)  

International Nuclear Information System (INIS)

Three different magnetic regimes; aerial, surface and buried; each with three different forces, have been used to investigate their effects on the water contents and photosynthetic pigments of sweet basil plants (Ocimum basilicum L.). Two groups of sweet basil seeds, Ocimum basilicum L. have been cultivated, one under normal conditions and the second has been subdivided into three portion (aerial, surface and buried) to examine the effect of different magnetic forces coming from the three directions on the resulted plants. At all directions of magnets, water contents have been significantly affected by the magnetic forces. Chlorophyll A and carotene contents have been affected, as well, according to the three magnetic forces coming from soil surface regime only. Chlorophyll B did not significantly affected by differences magnetic forces in the three regimes, but ...

181

THE APPLICATION OF STEEP PULSE CURRENTS TO THE ...  

Science.gov (United States)

... Title : THE APPLICATION OF STEEP PULSE CURRENTS TO THE ELECTROHYDRAULIC AND MAGNETIC FORMING OF METALS. ...

1966-04-01

188

Recovery Effects of a 180?mT Static Magnetic Field on Bone Mineral Density of Osteoporotic Lumbar Vertebrae in Ovariectomized Rats  

UK PubMed Central (United Kingdom)

The effects of a moderate-intensity static magnetic field (SMF) on osteoporosis of the lumbar vertebrae were studied in ovariectomized rats. A small disc magnet (maximum magnetic flux density 180 mT)...Full Text Available

2011-01-01

189

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

190

Perpendicular magnetic anisotropy of ultrathin FeCo alloy films on Pd(0 0 1) surface: First principles study  

International Nuclear Information System (INIS)

Using the full potential linearized augmented plane wave (FLAPW) method, thickness dependent magnetic anisotropy of ultrathin FeCo alloy films in the range of 1 monolayer (ML) to 5 ML coverage on Pd(0 0 1) surface has been explored. We have found that the FeCo alloy films have close to half metallic state and well-known surface enhancement in thin film magnetism is observed in Fe atom, whereas the Co has rather stable magnetic moment. However, the largest magnetic moment in Fe and Co is found at 1 ML thickness. Interestingly, it has been observed that the interface magnetic moments of Fe and Co are almost the same as those of surface elements. The similar trend exists in orbital magnetic moment. This indicates that the strong hybridization between interface FeCo alloy and Pd gives rise to the large magnetic moment. Theoretically calculated ...

2009-06-01

192

Optimization of soft magnetic properties in Fe-B and Fe-B-Si amorphous alloys obtained by melt spinning method  

International Nuclear Information System (INIS)

In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)

2001-09-23

193

NASA Technical Reports Server - Magnetic forming coil design and ...  

Science.gov (United States)

Site Error There's a problem with your browser or settings. ...

198

Magnetic forming studies  

Science.gov (United States)

Elastodynamic approach to measuring stress-strain relationship of uniaxially stressed wire, and

1967-01-01

200

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

201

Magnetic electronic lenses, quadrupole and octupole for microsystem electron beam techniques  

International Nuclear Information System (INIS)

The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered

2006-09-01

205

Influence of rotation and magnetic field on the minimum mass of a main-sequence star  

Energy Technology Data Exchange (ETDEWEB)

The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.

1980-11-01

222

A STUDY TO DETERMINE THE DEFORMATION ...  

Science.gov (United States)

... crystals and polycrystals. Nevertheless, explosive forming, magnetic forming, etc., are all high-strain-rate processes that ...

1963-04-01

223

A HELICAL MAGNET DESIGN FOR RHIC.  

Energy Technology Data Exchange (ETDEWEB)

Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.

1997-05-12

224

Whole Catchment Land Cover Effects on Water Quality in the Lower Kaskaskia River Watershed  

British Library Electronic Table of Contents (United Kingdom)

Agricultural runoff is a major non-point source pollutant and is the leading impairment of streams and rivers in the USA. This study examined the effects of agricultural, forest and urban land cover on water quality at the watershed level. Forty-three catchments ranging from 12 to 50?km2 were selected based on a land cover gradient within Lower Kaskaskia River Watershed in Illinois. Grab samples were collected and analyzed for nutrients, bacteria, and total suspended solids (TSS). Forest land cover was included in six of the ten regression models produced. Four of these regression models were for base flow conditions, suggesting that forest land cover had a significant impact on base flow water quality. Urban land cover was also included in six of the regression models. However, the majori...

2011-01-01

225

Thermoactivation of viruses by microwaves  

Energy Technology Data Exchange (ETDEWEB)

Eight different viruses, suspended in drinking water, were examined for their ability to be inactivated by microwaves from a microwave oven. Up to a virus content of 10/sup 5/ TCID/sub 50//ml inactivation was successful within a few minutes of microwave treatment and occurred in parallel to the heat stability of the viruses. Evidence for direct effects of microwaves on viruses could not be detected. 7 of the viruses studied were inactivated rapidly when temperatures of 50 to 65/sup 0/C under microwave treatment were reached in the flowing water, while a bovine parvovirus was only inactivated by temperatures above 90/sup 0/C. The advantages of a thermal virus-decontamination of fluids and material by microwaves are discussed.

1981-01-01

226

The results of physical modeling of flow in an axial cyclone combustion chamber; Ergebnisse physikalischer Modellierung der Stroemung in einer Axialzyklonbrennkammer  

Energy Technology Data Exchange (ETDEWEB)

The isothermal flow field for the axial cyclone has been experimentally determined. The velocity fields are used for determination particle paths (particle removal and suspended state), and inter alia of heat and mass transfer processes in the axial cyclone combustion chamber. The results are extremely significant as input value approximations for mathematical modelling, since experimentally obtained results are indispensable for complex flows and geometries. (orig.) [Deutsch] Es ist fuer den Axialzyklon experimentell das isotherme Stroemungsfeld ermittelt. Die Geschwindigkeitsfelder dienen zur Ermittlung der Partikelbahnen (Partikelabscheidung, Schwebebedingung), der Waerme- und Stoffuebertragungsprozesse u.a. in der Axialzyklonbrennkammer. Die Ergebnisse sind als Startwertnaeherung bei einer mathematischen Modellierung sehr wichtig, da bei komplexen Stroemungen und Geometrien versuchstechnische Ergebnisse unumgaenglich sind. (orig.)

1994-12-31

227

Tea catechins prevent contractile dysfunction in unloaded murine soleus muscle: A pilot study  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveExtended periods of muscle disuse, physical inactivity, immobilization, and bedrest result in a loss of muscle mass and a decrease in muscle force, which are accompanied by an increase in oxidative stress. We investigated the effects of the intake of green tea catechins on unloading-induced muscle dysfunction in tail-suspended mice. MethodsTen-week-old male BALB/c mice were fed a purified control diet or a diet containing 0.5% tea catechins for 14 d. Thereafter, the mice were subjected to continuous tail suspension for 10 d. On the final day, muscle mass, contractile force production, antioxidant potential, and carbonylated protein levels were evaluated. ResultsHind limb unloading caused a loss of soleus muscle weight and muscle force. Intake of tea catechins significantly inhibit...

2011-01-01

228

Study of coastal water zone ecosystem health in Zhejiang Province based on remote sensing data and GIS  

British Library Electronic Table of Contents (United Kingdom)

The coastal ecosystem health assessment is a field of increasing importance. In this paper, a preliminary assessment of ecosystem health in Zhejiang coastal water zone was made, mainly based on remote sensing data and GIS technique. Its spatial and quantitative evaluation was facilitated by the progress of remote sensing and GIS technique development. Firstly, human activities, hydrology and ecosystem problems in the study area were discussed and analyzed. Secondly, from 4 aspects of human stress, physical, chemical and biological responses to anthropogenic activities and natural stress, several indicators such as water transparency (Secchi Disk Depth, SDD), suspended substance concentration, dissolved inorganic nitrogen, active phosphate, chlorophyll, harmful algae bloom, as well as distr...

2010-01-01

229

Scale prevention with special reference to threshold treatment  

Energy Technology Data Exchange (ETDEWEB)

Various chemical, physical, and mechanical methods to prevent unwanted deposition of mineral scale are described. The suitability of the different methods, which largely depends on the specific features and requirements of the system involved, is discussed. Special emphasis is placed upon the threshold treatment, where the growth process is retarded by the addition of trace amounts of growth inhibitors. Growth experiments have been performed on barium sulfate and calcium sulfate dihydrate seed crystals, suspended in a supersaturated solution with and without organic bisphosphonates as inhibitors. Two methods are selected for the analysis of the growth data. A degree of inhibition is defined to obtain a quantitative description of the influence of a growth inhibitor on the growth rate of the crystals. In addition the influence of the molecular structure of various bisphosphonates with different substituents is shown. The effect of a bisphosphonate on the geometry of ...

1983-01-01

230

Retrieval of chlorophyll a concentration from a fluorescence enveloped area using hyperspectral data  

British Library Electronic Table of Contents (United Kingdom)

It is acknowledged that fluorescence line height (FLH) algorithms are still hampered by the uncertainty of fluorescence peak position. The fluorescence peak moves to longer wavelengths with the increase of chlorophyll a concentration. In this article, the fluorescence enveloped area (FEA), which integrates the fluorescence height and the fluorescence peak position, was used to estimate the chlorophyll a concentration in the coastal waters of the Pearl River Estuary. The FEA algorithm was developed from in situ data of chlorophyll a concentration, total suspended matter (TSM) concentration and above-water remote sensing reflectance, which were collected at 37 sampling stations in the Pearl River Estuary during two cruises. The results showed that the FEA algorithm made a better estimation o...

2011-01-01

231

Remote sensing analysis of rainstorm effects on sediment concentrations in Apalachicola Bay, USA  

British Library Electronic Table of Contents (United Kingdom)

Remote sensing of total suspended solids (TSS) by satellite techniques in estuaries and bays plays an important role in monitoring water quality over a large area. It is valuable to the management of coastal water environment and ecosystems. In this study, remote sensing mapping of TSS was conducted to investigate the effects of rainstorm events on Apalachicola Bay. A rainstorm event (October 7-8, 2008) was selected for a period when wind speeds were weak and the river inflow was almost steady. TSS mapping of MODIS images before and after the rainstorm event showed substantial increase of TSS induced by the rainstorm. Using an image during low river discharge before the rainstorm as a reference, TSS distribution was mapped by an improved regression model using MODIS image after a rainstorm...

2011-01-01

232

Relocatable explosives storage magazine  

Energy Technology Data Exchange (ETDEWEB)

A relocatable storage magazine apparatus for storing and retrieving explosives and ordnance and for partially containing and attenuating the blast, conflagration and flying debris from an accidental explosion is described comprising: (a) a container having an access hole; (b) a debris trap attached to the container, the debris trap communicating with said container via the access hole, said debris trap having vent holes for venting the pressure of an explosion from said debris trap to the atmosphere; (c) means for covering said access hole; (d) means for suspending explosives and ordnance from the covering means; (e) means for entering the storage magazine to store and retrieve explosives and ordnance; (f) means for retaining said covering means in a position above the access hole wherein said explosives and ordnance are accessible from the entering means.

1993-06-08

233

Oxygen dynamics in periphyton communities and associated effects on phosphorus release from lake sediments  

Energy Technology Data Exchange (ETDEWEB)

Periphyton is typically a heterogeneous assemblage of filamentous and single celled photoautotrophic and heterotrophic micoorganisms suspended in a mucopolysaccharide matrix which they produce. By definition, the assemblage is attached to a substratum such as rock, sediment, or plant in an aquatic environment. Microtechniques with high spatial and temporal resolution are required to define metabolic interactions among the heterotrophic and autotrophic constituents, and between periphyton and its environment. This study used oxygen sensitive microelectrodes with tip diameters of < 30 m to investigate the effects of photosynthesis and respiration on the oxygen dynamics of several diverse periphyton communities both in situ and in laboratory microcosms. A novel flow-through system that utilized TSP radiotracer and that permitted manipulation of the velocity, flushing rate, and oxygen concentration of overlying water was developed to investigate the role of ...

1986-01-01

234

Modeling dispersion and deposition of smoke generated from chemical fires  

British Library Electronic Table of Contents (United Kingdom)

Abstract Smoke is a mixture of toxic gases and suspended particulate matter of solids and liquids that evolves from a fire of flammable materials. This article presents real-time consequence modeling to track the concentration of individual species in smoke as well as its soot deposition. In the modeling process presented, the burning rate or vapor mass is fed into a combustion model in which the combustion of products has been identified and quantified along with the temperature of the fire. The output of the combustion model is the smoke that will be dispersed into the ambient. The fire geometry, which depends on the type of fire (e.g., pool or flare), is identified. A dispersion model with the capability of determining particulate deposition is then used for tracking the smoke plume. Th...

2011-01-01

235

Investigation of the removal efficiency of gasborne particles in a scrubber column  

Energy Technology Data Exchange (ETDEWEB)

Tests on the scrubbing column have led to the following results: Use of a scrubbing column with Raschig rings is only meaningful for the sedimentation of particles exceeding diameters of 0.5 ..mu..m; drops of diameter size 1.5 ..mu..m are formed in the column; more efficient drop precipitators in the column air flow ease the load on subsequent suspended material filters thereby contributing to a longer life of these filters even at higher sodium ion concentrations in the washing water; with distillate of an 8% rather than 0.8% salt solution a decontamination factor greater than 10 can be calculated since larger particles precipitate more readily. This only applies, however, under the condition that the washing water is renewed regularly, if necessary daily where higher aerosol concentrations are present. If not, the decontamination factor will be reduced through the salt-containing secondary aerosols from the washing water.

1983-01-01

236

Investigation of the removal efficiency of gasborne particles in a scrubber column  

International Nuclear Information System (INIS)

Tests on the scrubbing column have led to the following results: Use of a scrubbing column with Raschig rings is only meaningful for the sedimentation of particles exceeding diameters of 0.5 #mu#m; drops of diameter size 1.5 #mu#m are formed in the column; more efficient drop precipitators in the column air flow ease the load on subsequent suspended material filters thereby contributing to a longer life of these filters even at higher sodium ion concentrations in the washing water; with distillate of an 8% rather than 0.8% salt solution a decontamination factor greater than 10 can be calculated since larger particles precipitate more readily. This only applies, however, under the condition that the washing water is renewed regularly, if necessary daily where higher aerosol concentrations are present. If not, the decontamination factor will be reduced through the salt-containing secondary aerosols from the washing water. (orig.).

237

Investigation of Tumor-Peritoneal Interactions in the Pathogenesis of Peritoneal Metastases using a Novel Ex Vivo Peritoneal Model1  

British Library Electronic Table of Contents (United Kingdom)

BackgroundPeritoneal metastasis occurs in up to 30% of patients with gastric cancer. The aim of this experimental study is to develop and validate a novel ex vivo model of the human peritoneum to better identify factors involved in the development of peritoneal metastasis in order to improve its management and prognosis. MethodsPeritoneal discs harvested from hernia sacs obtained at inguinal hernia surgery were suspended in media using Teflon rings. Viability of the tissue was investigated using MTS assay, light and scanning electron microscopy (LM and SEM) over 72 h. To assess validity of the model, phenotypic changes in tumor cells were investigated. Changes in matrix metalloproteinases (MMP)-2 and -9 activities in HGC and AGS gastric adenocarcinoma cells after co-culture were investigat...

2010-01-01

238

In vitro diffusion bed, 3-day repeat challenge `capacity' test for antimicrobial wound dressings:  

British Library Electronic Table of Contents (United Kingdom)

Greenman J, Thorn RMS, Saad S, Austin AJ. In vitro diffusion bed, 3-day repeat challenge `capacity' test for antimicrobial wound dressings. Int Wound J 2006;3:322-329. Abstract The aim of this study was to develop an in vitro wound infection model that allows the comparison of the bacterial kill rate of antimicrobial wound dressings over the course of 3 days, with renewed microbial challenges each day, under realistic wound-like conditions. A test bed model of a moderately exuding wound was constructed from a hydrogel containing releasable foetal calf serum (FCS), and cellulose discs dosed with test microbes (Methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa) suspended in 50% FCS applied at the interface between the test dressing and the hydrogel test bed. Freshly prep...

2006-01-01

239

Gradiometry coexperiments to the gravity probe B and step missions  

Energy Technology Data Exchange (ETDEWEB)

The Gravity Probe-B (GP-B) spacecraft, designed to test predictions of general relativity, will fly in the mid 1990s. It will carry four electrostatically suspended gyroscopes in a cryogenic environment and will have a drag-free control system to minimize disturbances on the gyroscopes. The Stanford Test of Equivalence Principle (STEP) spacecraft, to fly later, will carry a set of test masses under very similar conditions. The possibility of using differential measurements of the GP-B gyroscopes suspension forces and the STEP tests mass displacement readout to form single-axis gravity gradiometers is explored. It is shown that the noise in the suspension systems is sufficiently small in the relevant frequency range, and that enough information is collected to compensate for the spacecrafts' attitude motion. Finally, using Breakwell's flat-earth approximation, these experiments are compared to other geodesy experiments and predict the contribution ...

1990-01-01

240

Fates of dissolved and particulate materials from the Mississippi river immediately after discharge into the northern Gulf of Mexico, USA, during a period of low wind stress  

British Library Electronic Table of Contents (United Kingdom)

In June 2003, we conducted a two-part field exercise to examine biogeochemical characteristics of water in the lower Mississippi river during the 4 days prior to discharge and in the Mississippi river plume over 2 days after discharge. Here we describe the fates of materials immediately after their discharge through Southwest Pass of the Mississippi delta into the northern Gulf of Mexico. Changes in surface water properties immediately after discharge were much larger and more rapid than changes prior to discharge. Total suspended matter (TSM) declined, probably due to sinking, dissolved macronutrients were rapidly diminished by mixing and biological uptake, and phytoplankton populations increased dramatically, and then declined. This decline appeared to begin at salinities of approximatel...

2008-01-01

241

Evaluation of the addition of various surfactant-suspended carbon nanotubes in MEEKC with an in situ-synthesized surfactant system  

British Library Electronic Table of Contents (United Kingdom)

Abstract Dispersions of single-walled carbon nanotubes (SWNTs) in various surfactant solutions have been systematically evaluated as additives in MEEKC. The compounds examined were catechins, phenolic acids, and flavonoids. Compared with zwitterionic and neutral surfactants, the addition of anionic dispersion seemed to be better at separating the three types of analytes in microemulsion system. In order to achieve low operating currents, an in situ-synthesized surfactant system based on the combination of a long-chain alkyl acid with an organic base was used in MEEKC. The optimized buffer contained 0.5% (57-mM) ethyl acetate, 0.6% (30-mM) lauric acid, 4.0% (666-mM) propanol, 50-mM Tris solution, and 4.5-mg/L the dispersion of SWNTs. Under optimized conditions, the established method was ap...

2011-01-01

242

Erosion below submarine structures  

Energy Technology Data Exchange (ETDEWEB)

A numerical model for the development of bed dominated scour around sub-sea structures is presented. The hydrodynamic part of the model is based on a modified potential flow theory. The purpose of the present study has been to develop relatively simple models, yet complex enough to capture the main physics that can be used as engineering tools. An overview of scour phenomena and the basic problems of scour in steady current flow is presented. A hydrodynamic model for horseshoe vortex is presented, as well as a model for the bed transport, and examples are given. The scour in oscillatory flow and a curvilinear model for suspended sediment calculations are described. An advection-diffusion model (formulated in a curvilinear stretched coordinate system) has been developed and is described in an article which has been submitted for publication, a copy of the article is enclosed in Appendix E of the report. (EG)

1997-07-01

243

Emissions Inventory Report Summary Reporting Requirements for the New Mexico Administrative Code, Title 20, Chapter 2, Part 73 (20 NMAC 2.73) for Calendar Year 1998  

Energy Technology Data Exchange (ETDEWEB)

Los Alamos National Laboratory (the Laboratory) is subject to emissions reporting requirements for regulated air contaminants under Title 20 of the New Mexico Administrative Code, Chapter 2, Part 73 (20 NMAC 2.73), Notice of Intent and Emissions Inventory Requirements. The Laboratory has the potential to emit 100 tons per year of suspended particulate matter, nitrogen oxides, carbon monoxide, sulfur oxides, and volatile organic compounds. For 1998, combustion products from the industrial sources contributed the greatest amount of criteria air pollutants from the Laboratory. Research and development activities contributed the greatest amount of volatile organic compounds. Emissions of beryllium and aluminum were reported for activities permitted under 20 NMAC 2.72 Construction Permits.

1999-09-01

244

Electrophoretic deposition of ethanol steam-reforming catalysts on metal plates for the development of catalytic-wall reactors  

British Library Electronic Table of Contents (United Kingdom)

A procedure based on electrophoretic deposition (EPD) was developed to coat metal plates with powder catalysts. The method was tested on stainless-steel plates with three Ni-based catalysts for the steam reforming of ethanol. The catalysts (Ni/La2O3/g-Al2O3) contained 15% Ni and 8% La, and were prepared using three types of g-alumina with different textural properties. The powder catalysts were suspended in isopropanol, and EPD deposition was performed with a voltage of 100V and a distance between electrodes of 2cm. Deposition time was varied between 3 and 7min, which gave a thickness of the catalyst layer from around 30 to 100mm. The morphology of the catalyst layer was dependent on the textural characteristics of the g-Al2O3 used to prepare the catalyst. The activity of the catalyst plat...

2010-01-01

245

Chondrocytes and bone marrow-derived mesenchymal stem cells undergoing chondrogenesis in agarose hydrogels of solid and channelled architectures respond differentially to dynamic culture conditions  

British Library Electronic Table of Contents (United Kingdom)

Abstract The objective of this study was to investigate how a combination of different scaffold architectures and rotational culture would influence the functional properties of thick cartilaginous tissues engineered using either chondrocytes or bone marrow-derived mesenchymal stem cells (BM-MSCs). Expanded porcine chondrocytes and BM-MSCs were suspended in 2% agarose and cast in custom-designed moulds to produce either regular solid or channelled construct cylinders. The study consisted of three seperate experimental arms. First, chondrocyte and BM-MSC constructs were cultured in free swelling conditions for 9 weeks. Second, constructs were subjected to rotational culture for a period of 3 weeks. Finally, BM-MSC-seeded constructs were subjected to delayed rotational culture, in which cons...

2011-01-01

246

Calorimetric sensors for energy deposition measurements  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.

1998-12-31

247

A Quantum-Enhanced Prototype Gravitational-Wave Detector  

CERN Document Server

The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by injection of a squeezed state of light. This ...

2008-01-01

248

A Comparative Study of Hydrodistillation and Hydrodistillation?Solvent Microextraction Methods for Identification of Volatile Components of Echinophora cinerea  

British Library Electronic Table of Contents (United Kingdom)

A recently developed hydrodistillation?solvent microextraction (HD?SME) method coupled to gas chromatography?mass spectrometry (GC?MS) was applied to the analysis of volatile components of aerial parts of Echinophora cinerea (Boiss). By the use of a simplex optimization method, the effects of extraction time, sample weight and microdrop volume on the extraction efficiency of the method were optimized. In the optimized conditions, 3??L of n-heptadecane was suspended in the headspace of 6?g of hydrodistillating sample, using a microsyringe. After 7?min, the solvent was retracted back into the syringe and directly injected into the GC?MS injection port. The HD?SME method was compared to a conventional hydrodistillation technique. In general, the extraction with HD?SME was relatively faster an...

2009-01-01

249

2010 power generation sector restructuring in Romania-A critical assessment  

International Nuclear Information System (INIS)

In the spring of 2009, the Romanian government has proposed a restructuring of the national power generation sector segment that is still owned by the state. As most of the power generation capacity is still state-owned, this restructuring will dramatically alter the competitive landscape of this sector. This paper is analyzing the rationale and principles of the restructuring as stated by government documents and officials, the assessment methodology and criteria proposed by the government, as well as the proposed final outcome of the restructuring initiative. Based on this critical assessment and the early results of the restructuring's implementation, we are able to make recommendations that can be considered for a revised restructuring approach. - Research highlights: #-># Power generation sector restructuring is proposed in 2009 by the Romanian government. #-># We assess the objectives, methodology and proposed outcome of the restructuring. #-># Proposed restructuring is ...

2011-03-01

250

Magnetocaloric and magnetoresistance studies of GdPd{sub 2}Si  

Energy Technology Data Exchange (ETDEWEB)

The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...

2001-01-22

251

Magnetocaloric and magnetoresistance studies of GdPd_2Si  

International Nuclear Information System (INIS)

The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...

2001-01-22

252

Magnetic separation anxiety  

International Nuclear Information System (INIS)

This paper reports that only a few years ago superconducting magnetic separation was viewed as the next major market for superconducting magnets. The first commercial units had been installed, worked flawlessly, and demonstrated real economic viability. The potential market was seen as quite large, and many people believed that superconducting magnetic separation would soon show the same rapid growth that MRI had demonstrated after its initial success. These hopes even prompted IGC, one of the top MRI magnet builders, to form a separate division devoted to magnetic separation. Despite the existence of Magstream, IGC has not been overly active in the market. As a technology that has applications from the clay on the Earth to the soil on the moon, superconducting magnetic separation has yet to become widely used.

1992-01-01

253

High-mode-number ballooning modes in a heliotron/torsatron system: 1, Local magnetic shear  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal force balance in the stellarator-like ...

1996-05-01

254

Effect of the induced magnetic field on peristaltic flow of a couple stress fluid  

Science.gov (United States)

We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and ...

2008-06-01

255

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

256

On the temperature dependence of the magnetic excitations  

International Nuclear Information System (INIS)

We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# function shows that ...

2005-07-15

257

Theory of zwitterionic molecular-based organic magnets  

British Library Electronic Table of Contents (United Kingdom)

We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.

2011-01-01

258

Occurrence of magnetism in superconductors  

Science.gov (United States)

We discuss how magnetic phenomena affect superconductivity in simple metals, transition metals and alloys thereof, and dilute Rare-Earth alloys. It is shown both qualitatively and quantitatively that superconductors are sensitive probes for studying itinerant spin excitations, local spin excitations associated with nearly magnetic impurities, the effect of the atomic environment on the stability of local magnetic moments, and the nature of the spin order in Rare-Earth alloys. Also, we discuss how magnetic impurities can be used to study the electronic configuration which is responsible for superconductivity in Laves-phase crystals like A-15 compounds and ..beta..-W crystals, for example.

1970-12-14

259

Magnetic response of ultrathin Fe on MgO: A polarized neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.

1994-11-15

260

Magnetic properties of glasses from geothite industrial wastes recycling (FeOOH)  

International Nuclear Information System (INIS)

It has been carried out the magnetic properties determination for high iron oxide content glasses series obtained from a geothite red mud waste from the zinc hydrometallurgy and dolomite and glass cullet as main raw materials. It has been determined the magnetic susceptibility and magnetization values for the glasses here investigated. The results suggest that the magnetic behaviour are depending on the glass chemical composition, so that glasses can be differently classified like ferrimagnetic, ferromagnetic, superparamagnetic and paramagnetic. (Author) 6 refs.

261

Magnetic fluctuations in paramagnetic Mn{sub 0.81}Ni{sub 0.19}  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluctuations present in the paramagnetic Mn{sub 0.81}Ni{sub 0.19} system have been investigated by measuring inelastic magnetic neutron scattering from a single crystal at temperatures of 450, 585 and 700 K. Antiferromagnetic correlations are observed to be present at all the temperatures studied. The spectral width of the magnetic scattering has been observed to increase with temperature, while the spatial range of the magnetic correlations is seen to decrease as the temperature is raised. The wave-vector-dependent susceptibility is found to follow a Curie-Weiss law near the (1 0 0) position, in agreement with theoretical predictions.

2006-11-15

262

Hydromagnetic rotational braking of magnetic stars  

International Nuclear Information System (INIS)

It is suggested that the magnetic Ap stars can be rotationally decelerated to long periods by the braking action of the associated magnetic field on time scales of order 10"7--10"1"0 years depending on whether the star's dipole field is aligned perpendicular or parallel to the rotation axis. Rotation includes a toroidal magnetic field in the plasma surrounding a star, and the accompanying magnetic stresses produce a net torque acting to despin the star. These results indicate that it is not necessary to postulate mass loss or mass accretion for this purely hydromagnetic braking effect.

263

Correlation between Magnetic Field Quality and mechanical components of the Large Hadron Collider Main Dipoles  

CERN Document Server

The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.

2006-01-01

264

How the Performance of a Superconducting Magnet is affected by theConnection between a small cooler and the Magnet  

Energy Technology Data Exchange (ETDEWEB)

As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the ...

2005-09-08

265

Anisotropic Nd{endash}Fe{endash}B bonded magnets made from HDDR powders (invited)  

Energy Technology Data Exchange (ETDEWEB)

Anisotropic Nd{endash}Fe{endash}B magnet powders can be produced by the hydrogenationdecomposition-desorption-recombination (HDDR) process from Nd{endash}Fe@ xnB{endash}Co{endash}M ({ital M}=Ga, Zr, Nb, Hf, and Ta) alloys. The present status of those HDDR powders and the bonded magnets made from them are reviewed with regards to the powder particle size dependence of their magnetic properties, their magnetic thermal stability, and their magnetization behavior. The results of a mechanistic study on the recombination step are also presented. The magnetic properties of the anisotropic HDDR powder depend relatively little on the powder particle size. Bonded magnets with a density of {approximately}6.20 g/cm{sup 3} and a BH{sub max} of 18.5{endash}20.5 MGOe can be produced from anisotropic HDDR powders with particle sizes of below 300 {mu}m diam. ...

1996-04-01

266

Total suspended matter observation in the Pearl River estuary from in situ and MERIS data.  

Science.gov (United States)

Based on the cruise data collected in the Pearl River estuary (PRE) in May 2008, an empirical two-band model by using the ratio of R (rs) at 629 and 671 nm was established to retrieve total suspended matter (TSM) concentration with the determination coefficient (R(2)) of 0.854, mean relative error (MRE) of 7.483%, and root-mean-square error (RMSE) of 1.295 mg L(?-?1). To match with medium resolution imaging spectrometer (MERIS) bands, in situ remote sensing reflectance was re-sampled to the bandwidth of 10 nm. The relationship between TSM and re-sampled R (rs) at 620 nm (MERIS band 6) and 665 nm (MERIS band 7) are obtained (R(2) = 0.748, RMSE = 1.697 mg L(?-?1), MRE = 8.785%, n = 13). Additionally, to map the spatial distribution of TSM in the PRE, MERIS level_1B data were calibrated using a multiple linear regression model based on in situ R (rs). Another dataset collected in the PRE in January 2004 was used to validate the two-band model and also applied to map ...

2010-09-01

267

Spectral absorption properties of colored dissolved organic matter (CDOM) and total suspended matter (TSM) of inland waters  

Science.gov (United States)

Spectral absorption properties of total suspended matter (TSM) and colored dissolved organic matter (CDOM) are important for the use of the bio-optical model to estimate water quality parameters. This study aims to investigate the variation in the absorption coefficients of TSM and CDOM of inland waters. A total of 92 water samples were collected from Shitoukoumen Reservoir and Songhua Lake in Northeast China, analyzed for TSM and Chl-a, and measured for the absorption coefficient of TSM, CDOM and total pigments using a laboratory spectrophotometer. The absorption coefficient of TSM has been decomposed for phytoplankton and inorganic sediments. The results show that for Shitoukoumen Reservoir, CDOM has strong absorptions with shallow absorption slopes (i.e., the coefficient S in a(?)=a(?0)exp[-S(?- ?0)]) and large absorption at 355 nm; and for Songhua Lake, CDOM follows similar spectral absorption curves but less variation in the S value. The results also show TSM ...

2010-08-01

268

Role of E-cadherin in the induction of apoptosis of HPV16-positive CaSki cervical cancer cells during multicellular tumor spheroid formation.  

Science.gov (United States)

Multicellular tumor spheroids (MCTS) are three dimensional cell culture systems induced by suspension culture. MCTS are widely used in cancer research because of their similarity to solid tumors. CaSki cells are derived from a metastatic cervical cancer containing human papillomavirus 16 (HPV16). Cell death of CaSki cells in MCTS has been previously reported, and our model is used to better characterize the mechanisms of cell death of HPV16-positive keratinocytes. In this study, we found that apoptosis of CaSki cells was induced by suspension culture along with the formation of MCTS after 24 h of incubation. In suspended CaSki cells, monoclonal antibodies blocking E-cadherin function inhibited MCTS formation and suppressed suspension-induced apoptosis in a dose-dependent manner. Western blot for E-cadherin detected upregulation of the authentic 120 kDa band from MCTS of CaSki cells as well as a shorter 100 kDa band. Addition of EGF, whose receptor is known to form ...

2008-01-01

269

Performance evaluation of Magma Power Company's reinjection well No. 46-7 at the East Mesa KGRA, California  

Energy Technology Data Exchange (ETDEWEB)

The performance of the Magma Power Company's reinjection well No. 46-7 at East Mesa has been examined. Water was cooled to 100/sup 0/F(+-) to simulate total heat extraction and then tested using membrane filter flow procedures. The cooled water contains particles which are in the high colloid size range, and formation impairment by these particles is unlikely. There is evidence that acid soluble corrosion products and calcium compounds constitute about two thirds of the particulates, and that the acid insoluble residue contains precipitated silica, insoluble corrosion products, and possibly formation fines carried in the produced water. Under stabilized conditions, the suspended solids content of the water is less than 2 parts per million. However, during the frequent production well start ups, a higher concentration of suspended solids is carried in the produced water and into the injection well, conceivably augmenting fill in the ...

1980-02-01

270

Microbiological Comparison of Core and Groundwater Samples Collected from a Fractured Basalt Aquifier with that of Dialysis Chamber Incubated in Situ  

Energy Technology Data Exchange (ETDEWEB)

Microorganisms associated with fractured basalt core were compared to those suspended in groundwater pumped from the same well in the eastern Snake River Plain Aquifer (Idaho, USA). Two wells influenced to different degrees by a mixed-waste plume in the fractured basalt aquifer were examined. In one well, an array of dialysis cells filled with either deionized water or crushed basalt was equilibrated to compare the microorganisms collected in this fashion with those from core and groundwater samples collected in a traditional manner from the same well. Analyses were performed to characterize these samples and to provide a basis for comparison. These included total cell counts by microscopy; total biomass by phospholipid fatty acid analysis; enumerations of viable aerobic heterotrophs, groups of putative aerobic co-metabolic TCE-degraders and aerobic H2-oxidizing bacteria; mineralization of 14C- labeled acetate; and enrichments for dissimilatory iron-reducing ...

2004-04-01

271

Heat transfer augmentation by gas-particle two-phase flow  

International Nuclear Information System (INIS)

The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat transfer mode in high temperature region, the helium which is always used in high ...

1995-06-01

272

Anaerobic digestion as final step of a cellulosic ethanol biorefinery: Biogas production from fermentation effluent in a UASB reactor-pilot-scale results.  

Science.gov (United States)

In order to lower the costs for second generation bioethanol from lignocellulosic biomass anaerobic digestion of the effluent from ethanol fermentation was implemented using an upflow anaerobic sludge blanket (UASB) reactor system in a pilot-scale biorefinery plant. Both thermophilic (53 degrees C) and mesophilic (38 degrees C) operation of the UASB reactor was investigated. At an OLR of 3.5 kg-VS/(m(3) day) a methane yield of 340 L/kg-VS was achieved for thermophilic operation (53 degrees C) while 270 L/kg-VS was obtained under mesophilic conditions (38 degrees C). For loading rates higher than 5 kg-VS/(m(3) day) the methane yields were, however, higher under mesophilic conditions compared to thermophilic conditions. The conversion of dissolved organic matter (VS(diss)) was between 68% and 91%. The effluent from the ethanol fermentation showed no signs of toxicity to the anaerobic microorganisms. However, a high content of suspended matter reduced the degradation ...

2010-09-01

273

Kondo effect and impurity-impurity interaction in (La, Ce)B_6 alloys  

International Nuclear Information System (INIS)

Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY ...

1978-01-01

274

Development of magnetic separation system of magnetoliposomes  

Energy Technology Data Exchange (ETDEWEB)

The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was ...

2009-10-15

275

Anti-cancer drug loaded iron-gold core-shell nanoparticles (Fe@Au) for magnetic drug targeting.  

Science.gov (United States)

Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus simulating the human ...

2010-09-01

276

"1"5"1Eu-Moessbauer study of complex magnetism in Eu_2PdSi_3: Effect of Eu"2"+ substitution by Y"3"+ and of high pressure  

International Nuclear Information System (INIS)

With "1"5"1Eu-Moessbauer spectroscopy and other methods the complex magnetic properties of Eu_2PdSi_3, arising from the two crystallographically different lattice sites of the Eu"2"+ ions, have been already studied. Here we study the impact of magnetic dilution of the magnetic Eu"2"+ sites by non-magnetic Y"3"+ ions. A previous specific heat study has found reduced magnetic ordering temperatures with strong indication of disorder effects like in magnetic spin glasses. Here we provide from "1"5"1Eu-Moessbauer spectroscopy detailed information of the impact of Y"3"+ substitution on the magnetic properties of the two lattice sites, well distinguishable in the "1"5"1Eu-spectra. Since the substitution of the larger Eu"2"+ ions by the smaller Y"3"+ ions is connected with a lattice contraction, we also applied high pressure to the Eu_2PdSi_3 sample ...

2010-03-01

277

Resistivity, Hall effect, and magnetic susceptibility of UPd_2Si_2  

International Nuclear Information System (INIS)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

278

Resistivity, Hall effect, and magnetic susceptibility of UPd[sub 2]Si[sub 2  

Energy Technology Data Exchange (ETDEWEB)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

1993-12-15

279

Recycler model magnet test on temperature compensation for strontium ferrite  

Energy Technology Data Exchange (ETDEWEB)

The Recycler ring magnet will be made of Strontium ferrite permanent magnets. A strontium ferrite permanent magnet without compensation has a temperature coefficient of -0.2 % in dB/dT. To compensate this effect, we are utilizing 30 % Ni 70 % Fe alloy, a temperature compensation ferromagnetic material with a low Curie point. To search for optimum commercially available material and optimum condition, we made a couple of simple model magnets, and tested with several different compensating material. The test results are reported and its optimal conditions are shown. Several different configurations were tested including a possible 2 kG magnet configuration.

1995-10-01

280

Large specific absorption rates in the magnetic hyperthermia properties of metallic iron nanocubes  

CERN Document Server

We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large heating power.

2010-01-01

281

Itinerant magnetism of Gd_xLa_1_-_xMSi (M=Fe, Co) compounds  

International Nuclear Information System (INIS)

The magnetic properties of polycrystalline and single crystalline rare earth transition metal silicides Gd_xLa_1_-_xMSi (M =Fe, Co) were investigated. Magnetic measurements have been made in static magnetic fields up to 13 kOe and in pulsed magnetic fields up to 250 kOe in the temperature range from 4.2 to 350 K. The magnetic susceptibility in the paramagnetic state of all the investigated compounds obeys the Curie-Weiss law except for LaFeSi and LaCoSi. Increase of the La content in Gd_xLa_1_-_xFeSi compounds leads to a decrease of the Curie and Neel temperatures, which can be explained by a decrease of positive exchange interactions. (orig.).

1995-09-01

282

High Tc superconducting magnetic multivibrators for fluxgate magnetic-field sensors  

Science.gov (United States)

Sensitive and quick-response nonlinear inductance characteristics are found for high Tc superconducting (YBa/sub 2/Cu/sub 3/O/sub 7-chi/) disk cores at 77K in which soft magnetic BH hysteresis loops are observed. Various quick response magnetic devices such as modulators, amplifiers and sensors are built using these cores. The magnetizing frequency can be set to more than 20 MHz, which is difficult for conventional ferromagnetic bulk materials such as Permalloy amorphous alloys and ferrite. New quick-response fluxgate type magnetic-field sensors are made using ac and dc voltage sources. The former is used for second-harmonic type sensors, while the latter is for voltage-output multivibrator type sensors. Stable and quick-response sensor characteristics were obtained for two-core type multivibrators.

1989-09-01

283

Effect of magnet sorting using a simple resonance cancellation method on the RMS orbit distortion at the APS injector synchrotron  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.

1993-07-01

284

Effect of On-Chip Magnetic Shielding for TES Microcalorimeters  

British Library Electronic Table of Contents (United Kingdom)

We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...

2008-01-01

285

Design, Performance and Series Production of Superconducting Trim Quadrupoles for the Large Hadron Collider  

CERN Document Server

The Large Hadron Collider (LHC) will be equipped with several thousands of superconducting corrector magnets. Among the largest ones are the superconducting trim quadrupoles (MQTL). These twin-aperture magnets with a total mass of up to 1700 kg have a nominal gradient of 129 T/m at 1.9 K and a magnetic length of 1.3 m. Sixty MQTL are required for the LHC, 36 operating at 1.9 K in and 24 operating at 4.5 K. The paper describes the design features, and reports the measured quench performance and magnetic field quality of the production magnets. The MQTL magnet production is shared between CERN and industry. This sharing is simplified due to the modular construction, common to all twin-aperture correctors.

2006-01-01

286

Study on seismic stability of seawall in man-made island. Pt. 4. Deformation analysis of seawall during earthquake by DEM-FEM coupled analysis method (SEAWALL-2D)  

Energy Technology Data Exchange (ETDEWEB)

In the development of the man-made island siting technology of nuclear power plants, assessing the stability of the seawall against large ocean waves and earthquakes is indispensable. Concerning with the seismic stability of the seawall, prediction of the deformation like sliding and settlement of the seawall during earthquake including the armour units in front of the caisson becomes important factor. For this purpose, the authors have developed the two-dimensional DEM-FEM coupled analysis method (SEAWALL-2D) to predict the deformation of the seawall covered with the armour units during earthquake. In this method, movements of the armour units are calculated in DEM analysis part and deformation of the caisson, rubble moundsand seabed and back fill are calculated in FEM analysis part taking the nonlinearity of the soil materials based on the effective stress into account. Numerical simulations of dynamic centrifuge model tests of the seawall are conducted to verify ...

1999-02-01

287

Modeling grain size during hot deformation of IN 718  

Energy Technology Data Exchange (ETDEWEB)

Aerospace gas turbine disks operate in an environment of relatively high stresses caused by centrifugal forces and elevated temperatures. These severe conditions necessitate the need for materials with high temperature strength and good low cycle fatigue resistance. One class of alloys used for this task is the nickel base superalloys, out of which, IN 718 is the most widely used in the aerospace industry. The properties of IN 718 are attributed to the combined effects of the chemistry, heat treatment, and microstructure. The chemistry is tailored not only for solid solution strengthening but also for precipitation hardening developed during heat treatment, which combined with a fine grained microstructure lead to excellent mechanical properties such as low cycle fatigue resistance and elevated temperature strength. The properties of a gas turbine disk are sensitive to the microstructure, in particular the grain size, which is dependent on the processing history. ...

1999-12-17

288

Micro-hardness measurements to evaluate composition gradients in metal-based functionally graded materials  

Energy Technology Data Exchange (ETDEWEB)

Micro-Vickers hardness measurement has been used to determine the composition of functionally graded materials (FGMs). Materials used in the present study are Al-SiC, Al-Shirasu and Al-Al{sub 3}Ni FGMs, which are fabricated by a centrifugal method. The micro-hardness of the aluminum matrix for Al-SiC FGM markedly increases as the volume fraction of SiC particles increases. However, the tendency is not so clear in the cases of Al-Shirasu and Al-Al{sub 3}Ni FGMs. Plastic strain energy due to thermal misfits between the matrix and dipersed particles is calculated based on an elasto-plastic analysis by applying a shell theory after Lee et al. The hardness is correlated theoretically with the composition gradient through the mean plastic strain energy (responsible for dislocation density). It is concluded that the composition gradient of metal-based FGMs can be determined from micro-hardness measurements. (orig.)

2001-01-01

289

Measurement of the enrichment of uranium in the pipework of a gas centrifuge enrichment plant  

Energy Technology Data Exchange (ETDEWEB)

The US and UK have been separately working on the development of a NDA instrument to determine the enrichment of gaseous UF/sub 6/ at low pressures in cascade header pipework in line with the conclusions of the Hexapartite Safeguards Project viz. the instrument is capable of making a ''go/no go'' decision of whether the enrichment is less than/greater than 20%. Recently, there has been a series of very useful technical exchanges of ideas and information between the two countries. This has led to a technical formulation for such an instrumentation based on ..gamma..-ray spectrometry which, although plant-specific in certain features, nevertheless is based on the same physical principles. Experimental results from commercially operating enrichment plants are very encouraging and indicate that a complete measurement including set up time on the pipe should be attainable in about 30 minutes when measuring pipes of diameter around 110 mm.

1985-01-01

290

Lining of magnesium alloys with foils using shot peening  

Energy Technology Data Exchange (ETDEWEB)

To improve the surface properties of magnesium alloy, a lining process using shot peening was carried out. The lining of magnesium alloy with metals such as titanium and nickel is useful in heightening the corrosion and wear properties for the components. In the shot peening experiment, the foil set on the magnesium workpiece is pelted with many shots at a high velocity. The foil is bonded to the surface of the workpiece due to plastic deformation induced by the collision of the shots. A pure aluminum foil is inserted between the hard foil and magnesium workpiece to assist the bonding. To heighten the bondability, the foil and workpiece are heated and the flow stresses of the metals are reduced. In this experiment, a centrifugal shot peening machine with an electrical heater was employed. The workpieces were commercially magnesium alloys AZ31B and AZ91D, and the foils were commercially pure aluminum, pure titanium and pure nickel. The effects of collision speed and ...

2003-07-01

291

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced ...

1982-12-01

292

High-efficiency pump for space helium transfer. Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

A centrifugal pump was developed for the efficient and reliable transfer of liquid helium in space. The pump can be used to refill cryostats on orbiting satellites which use liquid helium for refrigeration at extremely low temperatures. The pump meets the head and flow requirements of on-orbit helium transfer: a flow rate of 800 L/hr at a head of 128 J/kg. The overall pump efficiency at the design point is 0.45. The design head and flow requirements are met with zero net positive suction head, which is the condition in an orbiting helium supply Dewar. The mass transfer efficiency calculated for a space transfer operation is 0.99. Steel ball bearings are used with gas fiber-reinforced teflon retainers to provide solid lubrication. These bearings have demonstrated the longest life in liquid helium endurance tests under simulated pumping conditions. Technology developed in the project also has application for liquid helium circulation in terrestrial facilities and for ...

1991-12-01

293

Granular flow considerations in the design of a cascade solid breeder reaction chamber  

International Nuclear Information System (INIS)

Both horizontally and vertically oriented rotating chambers with granular material held on the inner surface by centrifugal action are examined. Modifications to the condition for controlled quasi-static flow on an incline plane, phi/sub w/ < #alpha# < phi/sub r/, where phi/sub w/ is the wall friction angle, #alpha# is the angle of inclination of the plane, and phi/sub r/ is the drained angle of repose of the material are examined for the case of horizontal and vertical surfaces of revolution. Allowed included half angles for horizontally oriented chambers are likely to be in the range of 30"0 +- 10"0 for ceramic particles and metal surfaces. For vertical orientations the maximum half-angle of the top cone is slightly less than the wall friction angle phi/sub w/ while the lower portion can have a half angle as large as (90"0 - phi/sub w). Percolation of fines through shearing granular solids is briefly discussed and recommended experimental and calculational ...

1970-05-01

294

Further development of excentric screw pumps for reduction of fluid levels in gas wells; Weiterentwicklung von Exzenterschneckenpumpen zur Fluessigkeitsspiegelabsenkung in Gasbohrungen  

Energy Technology Data Exchange (ETDEWEB)

Beside sucker-rod-type pumps and submersible centrifugal pumps, excentric screw pumps (so-called progressing cavity pumps) belong to standard conveyors in the production of crude oil. The authors of the contribution under consideration present the further development of excentric screw pumps with respect to the reduction of fluid levels in gas wells. This further development is based on a co-operation between the operator (Rohoel Aufsuchungs AG (Gampern, Austria)), the pump supplier (NETZSCH Oilfield Products GmbH (Selb, Federal Republic of Germany)) and the Institute for Process Technologies and Machinery at the University of Erlangen-Nuernberg (Federal Republic of Germany). The authors report on first attempts with the excentric screw pump at Weizberg (Federal Republic of Germany), material investigations at the University of Erlangen-Nuernberg, optimization of pump components and pump systems as well as on the optimization of the entire drainage process. ...

2008-10-23

295

Effect of low-proof alcohol fumigation-fueling on crankcase oil dilution in a diesel-cycle engine. Final report  

Energy Technology Data Exchange (ETDEWEB)

An Allis-Chalmers, Model 2900, turbocharged diesel engine was converted to a dual-fuel engine in which ethyl alcohol was fumigated between the turbocharger and the intake manifold, and the diesel fuel was injected normally at a reduced rate. Tests were performed to determine if crankcase oil dilution that had occurred was caused by the following independent parameters: proof of the ethyl alcohol, crankcase oil temperature, engine load at maximum torque speed, and percentage of total energy in the form of ethyl alcohol. Engine tests were steady state for six hours, after which the crankcase oil was sampled for American Society for Testing and Materials (ASTM) laboratory tests for determination of flash points and fire points, water by centrifuge, water by distillation, and viscosity at room temperature. Results indicate a decrease in thermal efficiency and an increase in exhaust carbon monoxide as the percentage of total energy as alcohol is increased. Additional ...

1982-11-01

296

Effect of field natural rubber latex with different ammonia contents and storage period on physical properties of latex concentrate, stability of skim latex and dipped film  

British Library Electronic Table of Contents (United Kingdom)

The effect of ammonia treatment in field natural rubber (NR) latex with different storage period time on the properties of concentrated NR latex and stability of skim latex was investigated. Fresh NR latex was treated with various ammonia contents such as 0.35, 0.60 and 0.80% w/w, and then they were centrifuged to get the concentrated NR latex with 60% dry rubber content (DRC) containing 0.16, 0.18 and 0.25% w/w, respectively and skim NR latex with roughly 5% DRC containing 0.42, 0.60 and 0.80% w/w, respectively. The effect of storage times with ?0, 15, 30 and 45 days for concentrated NR latex with different ammonia contents on their properties such as alkalinity, magnesium content and viscosity was observed. It was found that generally, magnesium content in field NR latex and latex...

2009-01-01

297

Chemical process equipment for Hitachi. ; Featured equipment  

Energy Technology Data Exchange (ETDEWEB)

The present article describes the specialities in various chemical process equipment fabricated by Hitachi. It introduces the thin-film evaporator which heats, vaporizes and concentrates high viscosity fluid and slurry under thin-film conditions, the centrifugal extractor which uses a high speed rotating rotor to separate two kinds of immiscible liquids effectively in counter current contact conditions under a gravitational force ranging from 2,000G to 4,500G, the process gas boiler and heat pipe equipment which recovers exhausted heat effectively from various plants, the furnace and quench systems which are applied to olefin plants, EDC cracking and steam reforming, and the equipment which has been supplied to chemical plants operated under severe conditions, such as high temperature, high pressure and corrosive atmosphere. It was demonstrated that these technologies and know-hows accumulated from Hitachi's extensive experiences in chemical process ...

1993-01-01

298

( sup 14 C)-Sucrose uptake by guard cell protoplasts of pisum sativum, argenteum mutant  

Energy Technology Data Exchange (ETDEWEB)

Guard cells rely on import for their supply with reduced carbon. The authors tested by silicone oil centrifugation the ability of guard cell protoplasts to accumulated ({sup 14}C)-sucrose. Uptake rates were corrected after measurement of {sup 14}C-sorbitol and {sup 3}H{sub 2}O spaces. Sucrose uptake followed biphasic kinetics, with a high-affinity component below 1 mM external sucrose (apparent K{sub m} 0.8 mM at 25C) and a low-affinity nonsaturable component above. Uptake depended on pH (optimum at pH 5.0). Variations in the concentrations of external KCl, CCCP, and valinomycin indicated that about one-half of the sucrose uptake rate could be related to an electrochemical gradient across the plasmalemma. Total uptake rates measured at 5 mM external sucrose seem to be sufficient to replenish emptied plastids with starch within a few hours.

1991-05-01

299

Treatment of low-frequency pulsating magnetic field on amorphous alloy Fe_7_8Si_9B_1_3  

International Nuclear Information System (INIS)

Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe_7_8Si_9B_1_3 were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe_7_8Si_9B_1_3. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase (#alpha#-Fe(Si), the grain size, 2-10 nm) is 3-7%. The temperature rise ...

2007-07-15

300

The possible detection of magnetic monopoles and monopole tachyons  

International Nuclear Information System (INIS)

This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.

301

Temperature dependence of a twofold magnetic behaviour of a nanoscopic metal/silicon hybrid system - a comparison between Ni/Si and Co/Si  

Energy Technology Data Exchange (ETDEWEB)

The investigated hybrid nanocomposite consists of a porous silicon template with electrochemically embedded Ni or Co nanostructures and offers magnetic characteristics which can be tailored by the electrochemical process parameters during fabrication. A twofold magnetic behaviour can be observed, a first one due to the spinmagnetism at magnetic fields below the saturation magnetization of the deposited metals and a second non-saturating term at higher fields (>1 T up to 7 T) above the saturation magnetization. In case of Ni deposited within the pores this non-saturating term shows a paramagnetic characteristic and follows exactly the Curie-Weiss law, whereas for Co/porous silicon samples the temperature dependent magnetization shows some deviations from the Curie Weiss law. In this high field region a difference in the temperature dependence between Ni ...

2009-10-15

302

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system besides the ...

1980-03-01

303

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

304

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

305

Room-temperature magnetic properties of oxy- and carbonmonoxyhemoglobin  

UK PubMed Central (United Kingdom)

The magnetic susceptibility and the density of human oxy-(HbO2) and carbonmonoxyhemoglobin (HbCO) solutions of various concentrations have been measured at room temperature, with pure water...Full Text Available

1978-10-01

306

Residential magnetic fields and childhood leukemia: a meta-analysis.  

UK PubMed Central (United Kingdom)

OBJECTIVES: This article uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies of residential magnetic field...Full Text Available

1998-12-01

307

Print sec333photoindex (256 pages)  

Science.gov (United States)

Electro-Magnet. Antenna Panels Types Simulated Hail Stone Damage A.Panel ...... X-Band Klystron Electro Magnet. 11. I I. 333-6104 AcBc. 333-6105 Color ...

308

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

309

Nature of magnetic coupling between Mn ions in as-grown Ga1-xMnxAs studied by x-ray magnetic circular dichroism  

International Nuclear Information System (INIS)

The magnetic properties of as-grown Ga1-xMnxAs have been investigated by the systematic temperature and magnetic field dependent soft x-ray magnetic circular dichroism (XMCD) measurements in the Mn L2,3 absorption edge region. The XMCD intensity at high temperatures obeys the Curie-Weiss law, but residual spin magnetic moment appears already around 100 K, significantly above Curie temperature (Tc), suggesting that short-range ferromagnetic correlations are developed significantly above Tc. The high-field magnetic susceptibility becomes T-independent below TC, indicating that the AF interaction between the substitutional Mn (Mnsub and interstitial Mn (Mnint) ions, which becomes strong as the Mn concentration x increases, exists and that the amount of the Mnint affects Tc. The present experimental findings should give valuable insight into the inhomogeneous ...

2009-07-01

310

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

311

Magnetic and structural investigation of magnetic thin films with obliquely deposited underlayers  

CERN Document Server

An in-plane uniaxial magnetic anisotropy has been observed in thin Co films normally deposited onto obliquely sputtered Ta and Pt underlayers. Associated with this anisotropy is an augmented easy axis coercivity. The in-plane easy axis is, in most cases, perpendicular to the incident deposition plane. Microstructural results indicate that grains are well connected along the magnetic easy axis but are separated by long continuous voids along the hard axis, which is ascribed to a geometric shadowing effect due to the oblique incidence deposition of the underlayer. Hence, the magnetic anisotropy mimics the film growth anisotropy. It is therefore believed that the observed magnetic properties are due to magnetostatic shape anisotropy effects. In-plane coercivity and anisotropy field are shown to increase with underlayer deposition angle, underlayer thickness and magnetic layer ...

2002-01-01

312

Magnetic and chemical changes in marine sediments  

Energy Technology Data Exchange (ETDEWEB)

A considerable amount of chemical knowledge of marine sediments has been acquired in recent years but has not yet been utilized by paleomagnetists. On the other hand, geochemists are often unaware of the usefulness of numerous magnetic techniques. In this review we try to bridge this gap, and in particular, we outline many of the chemical and magnetic principles that should allow paleomagnetists to better identify and undertand chemical changes that affect the magnetic properties of marine sediments. The chemical principles include those for distinguishing the four major sources of sediments (continental, biological, authigenic/hydrogenous, volcanic/hydrothermal) from one another by determining elemental abundance distributions, as well as for investigating the stabilities of mineral phases relative to changes in pE and pH. The magnetic principles include the effects of authigenesis and diagenesis on ...

1980-05-01

313

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

314

Long-lived states to sustain hyperpolarized magnetization  

UK PubMed Central (United Kingdom)

Major breakthroughs have recently been reported that can help overcome two inherent drawbacks of NMR: the lack of sensitivity and the limited memory of longitudinal magnetization. Dynamic nuclear polarization...Full Text Available

2009-11-03

315

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

316

Epidemiological appraisal of studies of residential exposure to power frequency magnetic fields and adult cancers.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To appraise epidemiological evidence of the purported association between residential exposure to power frequency magnetic fields and adult cancers. METHODS: Literature review and epidemiological...Full Text Available

1996-08-01

317

Epidemiologic studies of electric and magnetic fields and cancer: strategies for extending knowledge.  

UK PubMed Central (United Kingdom)

Epidemiologic research concerning electric and magnetic fields in relation to cancer has focused on the potential etiologic roles of residential exposure on childhood cancer and occupational exposure...Full Text Available

1993-12-01

318

Energetic constraints on the creation of cell membrane pores by magnetic particles.  

UK PubMed Central (United Kingdom)

Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available

1996-08-01

319

Electric and magnetic field exposures for people living near a 735-kilovolt power line.  

UK PubMed Central (United Kingdom)

The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available

1995-09-01

320

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

321

Design of modular coils for a quasi-axisymmetric stellarator with a flexible control of the magnetic field configuration  

Energy Technology Data Exchange (ETDEWEB)

A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a flexibility of the magnetic field configuration is realized. For the case that the rotational transform ...

2002-08-01

322

Design and experimental results on a terawatt magnetically controlled plasma opening switch  

Energy Technology Data Exchange (ETDEWEB)

The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load ...

1998-05-01

323

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

324

A case cohort study of suicide in relation to exposure to electric and magnetic fields among electrical utility workers.  

UK PubMed Central (United Kingdom)

OBJECTIVES--This case cohort study examines whether there is an association between exposure to electric and magnetic fields and suicide in a population of 21,744 male electrical utility workers from...Full Text Available

1996-01-01

325

A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal...  

Science.gov (United States)

Name U.S. Geological Survey A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal Field, Nevada: A Web Site for Distribution of Data by U. S. Geological Survey &...

2011-08-20

326

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

327

Untitled - NASA Technical Reports Server  

Science.gov (United States)

the techniques employed at present, some of which, like magnetic forming and hotdrape forming, are in experimental stages. Published October 1965. ...

328

Thermal-physical analysis of low-radioactive thermonuclear plasma in the magnetic fusion device  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

330

The Effect of the Temperature to Which the Material is Heated ...  

Science.gov (United States)

... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...

1980-09-01

333

SELECTED LISTING OF ECHNOLOGY UTILIZATION PUBLICATIONS  

Science.gov (United States)

as magnetic forming and hot-drape forming. Details about the 25 techniques discussed incorporate the most recent improvements and ...

336

Read/write characteristics of focused-ion-beam-etched heads for perpendicular magnetic recording media  

International Nuclear Information System (INIS)

The read/write characteristics for perpendicular magnetic recording media of focused-ion-beam (FIB)-etched recording heads were investigated. It was found that the trailing edge of an FIB-etched head produces a higher gradient in the magnetic field perpendicular to the medium than a head which has not been etched. The signal-to-noise ratio of the medium increased with the FIB-etched write gap. A high-Bs and thin pole increased the magnetic field's gradient in the perpendicular direction, resulting in excellent read/write characteristics.

2001-10-01

337

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

338

Nuclear moments of the 11/2"- isomer in "1"8"7Ir  

International Nuclear Information System (INIS)

... excited states iridium 187 isomeric nuclei magnetic fields nuclear electric

339

Nuclear moments and changes in rms-radii of neutron-deficient silver isotopes  

International Nuclear Information System (INIS)

... nuclear electric moments nuclear magnetic moments nuclear radii quadrupole

1987-03-23

340

Nuclear magnetic resonance on oriented XVTa and XXTa  

Energy Technology Data Exchange (ETDEWEB)

XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.

1984-08-01

341

Nature of the magnetic susceptibility of dysprosium. Paramagnetic susceptibility of dysprosium - yttrium alloys  

International Nuclear Information System (INIS)

The paramagnetic susceptibility of single crystals of dysprosium-yttirum alloys is measured in the basal plane and along the hexagonal axis. It is shown that the susceptibility of the alloys obeys the Curie-Weiss law, the effective magnetic moments allong the different directions being the same and the paramagnetic Curie temperatures being different. The difference between the paramagnetic Curie temperatures in the basal plane and along the hexagonal axis is independent of the dysprosium concentration in the alloy. As a comparison with the theoretical models of magnetic anisotropy shows, this is an indication that the magnetic anisotropy of dysprosium - yttrium alloys is of a single-ion nature.

1976-01-01

342

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

343

Methods and instruments for nondestructive testing of the anisotropy of the magnetic properties of ferromagnetic sheet materials (review)  

Energy Technology Data Exchange (ETDEWEB)

This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.

1995-04-01

345

Magnetic structure of Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2  

International Nuclear Information System (INIS)

The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).

347

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

348

Magnetic properties of oxovanadium(IV) complexes with bidentate on donor Schiff bases  

International Nuclear Information System (INIS)

(Feb 1977). Japan Syamal, A. Bombay Univ. (India). Univ. Dept. of Chemical

1977-01-01

349

Magnetic phase diagrams of the TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} systems  

Energy Technology Data Exchange (ETDEWEB)

The a.c. susceptibility and high field magnetization of TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} compounds were investigated up to 140 kOe. The (T, x) magnetic phase diagrams were determined. For both systems, an increase in the Pd content causes a decrease in the Neel temperature and changes the magnetization curves. (orig.)

1995-12-01

350

Magnetic braking in weakly ionized media  

International Nuclear Information System (INIS)

The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.

351

Magnetic Tape Pulse Width to Digital Convertor.  

Science.gov (United States)

... This is achieved by the use of a unique logic circuit employing a plurality of flip-flop devices, multivibrators and AND gates. ...

1976-12-07

352

Magnetic Properties of a Material Used to Estimate Elastic and Plastic Strains of Ferrite?Pearlite Steels  

British Library Electronic Table of Contents (United Kingdom)

The effect of elastic and plastic strains on the magnetic properties of ferrite-pearlite steels has been studied. It has been shown that the sensitivity to elastic-tensile and bending strains is four to five times greater for remnant magnetization than for coercive force. In order to determine the degree of cold plastic deformation of high-carbon steels, a two-parametric testing technique based on the use of remnant magnetization and coercive force was suggested. An MMT-2 device was recommended for measurement of the required parameters.

2005-01-01

353

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

357

Injection and extraction magnets: septa  

CERN Document Server

An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.

2010-01-01

358

Influence of resonant US on H-NMR at application of magnetic nanoparticles  

International Nuclear Information System (INIS)

2010 [1 p.] Germany Repp, Felix El-Miladi, Nouri Hoehl, Christian Jahanbakhsh,

2010-03-21

359

From Rodinia to Gondwana: few paleo magnetic constraints; many speculations  

International Nuclear Information System (INIS)

... Trama; Montevideo (Uruguay) 70 p. GEOSCIENCES geologic history geologic

2001-11-12

363

Domain wall pining in a jointed ferromagnetic nano-wire  

Energy Technology Data Exchange (ETDEWEB)

The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.

2004-05-01

367

Conceptual design of a compact medical synchrotron with a hybrid magnet  

International Nuclear Information System (INIS)

English 2001 p. 178 China Iwashita, Y. Kumada, M. National Institute

2001-09-17

368

CAPACITOR DISCHARGE METAL FORMING  

Science.gov (United States)

... Report Date : JUL 1961. Pagination or Media Count : 39. Abstract : Open-ende Terms: Electrohydraulic forming, Magnetic forming. ...

1961-07-01

369

A preliminary design for a one GHz NMR spectrometer magnet  

International Nuclear Information System (INIS)

The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.

1993-09-20

370

A Profile of Defense Manufacturing Costs and Enabling ...  

Science.gov (United States)

... Casting Explosive forming Forging Electrohydraulic forming Extruding Magnetic forming Rolling Electroforming Drawing Powdered metal forming ...

1992-01-01

371

A GENERAL STUDY OF PROCESSES FOR THE ...  

Science.gov (United States)

... fields, materials can be subjected to energy densities exceeding those realized in high explosives, a fact which forms the basis for magnetic forming ...

1962-11-01

372

Use of magnetic treatment to intensify certain processes in the refining of chemical products of coking  

Energy Technology Data Exchange (ETDEWEB)

The results of the investigations show that magnetic treatment is a quite practical and effective method of intensifying certain technological processes in the coking industry. Magnetic treatment was utilized for improving the production of ammonium sulfate, refining of the naphthalene fraction, removal of sludge from wash oil in the benzol division, and the treatment of tar before fractionation. 2 references, 3 tables.

1983-01-01

373

Stability of superconducting ISABELLE dipole magnets  

Energy Technology Data Exchange (ETDEWEB)

The concept of the minimum propagating zone (MPZ) is used to examine the causes of quenches in ISABELLE cosine theta superconducting dipole magnets. The size of disturbances large enough to exceed the MPZ and initiate quenches is estimated and compared with the size of disturbances which may be produced in the magnets. A suggestion for reducing the size of these disturbances through individual support of the coil block is outlined.

1981-04-01

374

Self-simulating motion of an ionized gas expelled by a magnetic piston  

Energy Technology Data Exchange (ETDEWEB)

The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.

1980-01-01

375

Search for magnetic rotation in {sup 202}Pb and {sup 203}Pb  

Energy Technology Data Exchange (ETDEWEB)

High-spin states in {sup 202}Pb and {sup 203}Pb have been investigated by in-beam {gamma}-ray spectroscopy following the reaction {sup 198}Pt({sup 9}Be,xn). A search for magnetic rotational bands in these isotopes confirmed one of the two bands previously assigned to {sup 202}Pb and revealed a new band in this isotope. No evidence for magnetic rotation has been found in {sup 203}Pb. (orig.)

2000-11-01

376

Multidipole magnetic fields for plasma confinement  

Energy Technology Data Exchange (ETDEWEB)

Plasma confinement by permanent magnets has been studied. An analytic formula for the field of a single bar magnet has been obtained. Generalization to various configurations of multidipole fields has also been found. Any two-dimensional field may now be completely described by a simple function of complex variables in closed form. Vector potential has also been obtained by integrating over a prescribed Riemann surface. The confinement of plasma by multidipole fields then becomes obvious through conservation principles.

1983-07-01

377

Methods of reducing magnetic field near the transmission lines  

International Nuclear Information System (INIS)

Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.

2003-01-01

378

Mean magnetic moments of polycrystalline Ce compounds in a tetragonal crystal field  

International Nuclear Information System (INIS)

An alternative and graphical representation of the magnetic moment and the effective paramagnetic moment for polycrystalline Ce compounds with tetragonal site symmetry is described. The reduced moments can be calculated by means of standard perturbation theory. The calculated values deduced from the ground states of CeCu_2Si_2, CeRu_2Si_2, and CePd_2Si_2 polycrystals are compared with experimental magnetic moments.

379

Magnetic properties of heavy rare-earth tungstates  

International Nuclear Information System (INIS)

Measurement of the magnetic susceptibility of powder samples of heavy rare-earth (Tb, Dy, Ho, Er, Tm and Yb) tungstates have been reported in the temperature range 300 to 900 K. Curie-Weiss law behaviour has been observed for all samples. The Curie constant, paramagnetic Curie temperature and magneton number for the magnetic ions have also been evaluated for each material. (author).

1978-12-01

380

Magnetic properties of FeSi with cobalt impurities  

Energy Technology Data Exchange (ETDEWEB)

Results of experimental researches of impurity level crystals Fe1-xCoxSi are presented in this article. Magnetic properties in a temperature range up to T {<=} 1000 K are analyzed. It was established that with Co impurities increasing origin of magnetic ordering exists at low temperatures. At high temperatures a high temperature maximum of susceptibility of nominally pure iron monosilicide crystal is observed.

2010-01-01

381

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

382

Magnetic and valence transitions in CePd_2_-_xMn_xSi_2:L_I_I_I edge study  

International Nuclear Information System (INIS)

We report on solid solution CePd_2_-_xMn_xSi_2 which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.)).

383

Magnetic and valence transitions in CePd[sub 2-x]Mn[sub x]Si[sub 2]:L[sub III] edge study  

Energy Technology Data Exchange (ETDEWEB)

We report on solid solution CePd[sub 2-x]Mn[sub x]Si[sub 2] which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.))

1994-04-01

384

Kondo effect in the systems of magnetic trimers on a metal surface  

International Nuclear Information System (INIS)

Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)

2010-11-01

385

Invariant correlation functions, superconvergence sum rules, and electric-magnetic duality  

Energy Technology Data Exchange (ETDEWEB)

The gauge-invariant correlation function for the Yang-Mills field strengths is shown to admit a symmetric decomposition into electric and magnetic components. The spectral weights are seen to obey a sum rule of the superconvergence type, owing to asymptotic freedom. The close relation between the dielectric function, electric-magnetic duality, and the algebra of generalized Chern-Simons charges is illustrated for the linearized Yang-Mills-Higgs system.

1988-01-01

386

Instability of 4f and 3d magnetic moments under high pressure  

International Nuclear Information System (INIS)

The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).

387

Heat transfer augmentation using a magnetic fluid under the influence of a line dipole  

Energy Technology Data Exchange (ETDEWEB)

Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...

2004-04-01

388

Heat transfer augmentation using a magnetic fluid under the influence of a line dipole  

International Nuclear Information System (INIS)

Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...

2004-04-01

389

Experimental Verification of the Hall Effect during Magnetic Reconnection in a Laboratory Plasma  

Energy Technology Data Exchange (ETDEWEB)

In this letter we report a clear and unambiguous observation of the out-of-plane quadrupole magnetic field suggested by numerical simulations in the reconnecting current sheet in the Magnetic Reconnection Experiment (MRX). Measurements show that the Hall effect is large in collisionless regime and becomes small as the collisionality increases, indicating that the Hall effect plays an important role in collisionless reconnection.

2005-06-16

390

Effect of heat treatment on the properties of Metglas foils, and laminated magnetoelectric composites made thereof  

British Library Electronic Table of Contents (United Kingdom)

Annealing of magnetostrictive Metglas foils, subsequently incorporated into laminated Metglas/Pb(Zr, Ti)O3 magnetoelectric (ME) composites, is shown to result in improved magnetic properties, as well as ME coefficients. Annealing of the foils at 350 ?C resulted in partial crystallization, without oxidation or magnetic cluster formation that would reduce the magnetization. Laminate composites made with these annealed Metglas foils had improved ME coefficients.

2011-01-01

391

Direct conversion of fusion energy into the electric one in the 'Dragon' magnetic confinement system  

International Nuclear Information System (INIS)

It is shown that recuperator in which the thermal energy of particles is transformed into electric oue under drift in crossed fields is naturally coupled with dragontype magnetic confinement system, so the recuperation process can be initiated in the dragon magnetic field. A number of questions occuring under analysis of recuperator-dragon system is considered, including the dynamics of particle transfer to the recuperator, the share of particles entering the recuperator, the effect of rotational transform and the recuperation efficiency.

392

Current applications of magnetic resonance in coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)

1982-01-01

393

Conductance quantization in ferromagnetic Ni nano-constriction  

Energy Technology Data Exchange (ETDEWEB)

The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.

2002-02-01

394

Comment on 'Magnetic braking revisited: activities for the undergraduate laboratory'  

International Nuclear Information System (INIS)

Here, we consider a recent paper concerned with magnetic braking by induced currents (Ireson and Twidle 2008 Eur. J. Phys. 29 745-51). Our objective is to elucidate why measurement of speed in which a magnet is dropped through a non-ferromagnetic conductive tube depends on its geometry in a non-monotonic way, which was not clearly explained by the authors. (letters and comments)

2009-03-01

395

Bacterial cultivation in high magnetic fields by 7-tesla superconducting magnet; 7T chodendo magnet ni yori hasseishita kojiba ni okeru biseibutsu no baiyo  

Energy Technology Data Exchange (ETDEWEB)

Although a large number of studies on effects of magnetic fields on living organisms was reported, no definite results were obtained in many cases because the related conditions are non-uniform and uncertain, such that the uniform magnetic space is smaller than test samples, and temperature control is insufficient. Therefore, the present study developed a microorganism cultivation system that is applied with a 7-T superconducting magnet. This system has the following features: it generates homogeneous magnetic fields of 0.5 to 7 T {plus_minus} 0.5% in the space with a diameter of 100 mm and a length of 200 mm in a normal temperature bore (with a diameter of 160 mm); it can cultivate microorganisms aerobically at temperatures of 10 to 70{degree}C {plus_minus} 0.1{degree}C; it can perform the cultivation simultaneously with a control cultivation in a small magnetic field weaker than ...

1994-12-20

396

Ab initio calculations in a uniform magnetic field using periodic supercells  

Energy Technology Data Exchange (ETDEWEB)

We present a formulation of ab initio electronic structure calculations in a finite magnetic field, which retains the simplicity and efficiency of techniques widely used in first principles molecular dynamics simulations, based on plane-wave basis sets and Fourier transforms. In addition we discuss results obtained with this method for the energy spectrum of interacting electrons in quantum wells, and for the electronic properties of dense fluid deuterium in a uniform magnetic field.

2003-10-21

397

X-ray magnetic form factor of UTe  

Energy Technology Data Exchange (ETDEWEB)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

1995-07-01

398

X-ray magnetic form factor of UTe  

International Nuclear Information System (INIS)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

399

Transition-metal dimers and physical limits on magnetic anisotropy  

British Library Electronic Table of Contents (United Kingdom)

Recent advances in nanoscience have raised interest in the minimum bit size required for classical information storage. This bit size is determined by the necessity for bistability with suppressed quantum tunnelling and energy barriers that exceed ambient temperatures. In the case of magnetic information storage, much attention has centred on molecular magnets with bits consisting of about 100 atoms, magnetic uniaxial anisotropy energy barriers of about 50?K and very slow relaxation at low temperatures. Here, we draw attention to the remarkable magnetic properties of some transition-metal dimers, which have energy barriers approaching 500?K with only two atoms. The spin dynamics of these ultrasmall nanomagnets is strongly affected by a Berry phase, which arises from quasi-degen...

2007-01-01

400

The addition of trim coils to the Tandem Mirror Experiment magnet system to improve the magnetic field mapping  

International Nuclear Information System (INIS)

The mapping of the magnetic flux bundle from the center cell to the Plasma Potential Control plates (PPC) on the end fan of the Tandem Mirror Experiment Upgrade (TMX-U), was improved by the addition of trim coils (12,000 amp-turns) on each side of each end fan next to the pump beam magnetic shields. The coils' axes are oriented perpendicular to the machine centerline. These coils made the necessary corrections to the field-line mapping, while keeping the field in the nearby pump beam magnetic shield below the saturation threshold. This paper briefly describes the problem, discusses the design as it evolved, and presents the results of the field testing. A brief description of the improvement in the machine performance is also included.

401

Preliminary Calculations of the Radiation Damage of the Permanent Magnets for TRADE (TRiga Accelerator Driven Experiment)  

CERN Document Server

Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.

2002-01-01

402

Novelty, preparation, characterization and enhancement of magnetic properties of Mn nanoferrites using safety binder (egg white)  

British Library Electronic Table of Contents (United Kingdom)

Nanocrystalline MnFe"2O"4 ferrite was prepared by using autocombustion technique (flash). The microstructure and magnetic properties are studied. The results of XRD and TEM clarified that, this ferrite is nanosized with particle size (39 nm). Magnetic measurements showed a ferromagnetic behavior with T"C = 613 K, the saturation magnetization M"s = 13.71 emu/g, remanent magnetization M"r = 0.1694 emu/g and, coercivity H"c = 25.6 Oe. Natural material, egg white used as an aqueous medium to extend prepare nanoparticles better than other chemical interesting materials.

2011-01-01

403

Magnetic refrigeration: the promise and the problems  

Energy Technology Data Exchange (ETDEWEB)

Magnetic refrigeration uses the temperature- and field-dependence of the entropy of some magnetic materials to accomplish cooling. Because of the intrinsically high efficiency of the magnetization and demagnetization process and because of the potential for excellent heat transfer between solids and fluids, magnetic refrigerators promise to have higher efficiency than existing gas-cycle refrigerators. Many ground-based and space-based applications could benefit significantly from the cost savings implied by higher efficiency. Other attributes of these devices are high reliability and low volume and mass per unit cooling power. The development of these refrigerators is underway at several places around the world, including the Los Alamos National Laboratory. The progress to date has been encouraging but some problems have been clearly identified. The arguments for high efficiency and the problems that ...

1984-01-01

404

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is ...

1995-12-31

405

Magnetic Moments and Electromagnetic Radii of Nucleon and ?(1232) in an Extended Goldstone-Boson-Exchange Model  

International Nuclear Information System (INIS)

We derive the exchange currents of pseudoscalar, vector, and scalar mesons from Feynman diagrams, and use them to calculate the magnetic form factors of nucleon and ?(1232). The magnetic moments and electromagnetic radii are obtained by using those form factors and the parameters determined from the masses of nucleon and ?(1232). We find the magnetic moments and electromagnetic radii of nucleon and ?(1232) can be produced very well in the extended Goldstone-Boson-exchange model in which all of pseudoscalar, vector, and scalar meson nonet are included. The magnetic moments of ?(1232) are closer to experiment values and results from lattice calculation than the results obtained by the model without other mesons except for pion and sigma.

2005-01-15

406

Lorentz transmission electron microscopy investigation of magnetically patterned Co/Pt multilayers  

Energy Technology Data Exchange (ETDEWEB)

The switching behavior of magnetic patterns prepared by ion irradiation was investigated. Co/Pt multilayers with perpendicular anisotropy and large out-of-plane coercivities 5-6 kOe were grown on electron transparent SiN windows. Regularly spaced 1 micron sized regions, were magnetically pattered via ion beam irradiation through a stencil mask. Lorentz TEM was used to observe in-situ magnetization reversal processes of irradiated regions under well-defined applied magnetic fields. When the in-plane field was increased, domain wall motion was observed, resulting in the alignment of the patterns with the direction of the applied field. The switching mechanism of the in-plane patterns was by domain wall motion.

2000-08-01

407

Industrial production of RHIC magnets  

Energy Technology Data Exchange (ETDEWEB)

RHIC 8 cm aperture dipole magnets and quadrupole cold masses are being built for Brookhaven National Laboratory (BNL) by Northrop Grumman Corporation at a production rate of one dipole magnet and two quadrupole cold masses per day. This work was preceded by a lengthy Technology Transfer effort which is described elsewhere. This paper describes the tooling which is being used for the construction effort, the production operations at each workstation, and also the use of trend plots of critical construction parameters as a tool for monitoring performance in production. A report on the improvements to production labor since the start of the programs is also provided. The magnet and cold mass designs, and magnetic test results are described in more detail in a separate paper.

1996-07-01

408

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).

1993-06-01

409

Development of the SSC (Superconducting Super Collider) trim coil beam tube assembly  

Energy Technology Data Exchange (ETDEWEB)

The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.

1987-01-01

410

Crossover of the magnetic levels and adiabatic magnetization of the mesoscopic cluster V15  

British Library Electronic Table of Contents (United Kingdom)

The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...

2006-01-01

411

Application of GIS for the evaluation of human exposure to magnetic field in the vicinity of power lines  

Energy Technology Data Exchange (ETDEWEB)

Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.

1998-10-01

412

Use of neutron activation analysis for the control of air pollution of Algiers; Utilisation de l'analyse par activation neutronique pour le controle de la pollution de l'air d'Alger  

Energy Technology Data Exchange (ETDEWEB)

The urban zone needs clean air to assure public health. To achieve this goal several filter samples were collected in different sites in Algiers city. Toxic elements such as: Na, Mg, Cl, Sc, Cr, Ti, V, Fe, Co, Cu, Zn, Se, Br, Ag, Sb, Ce, La, Hf, Ta and Hg have been measured in the filters using neutron activation analysis technique. Irradiation of filter samples and standards were carried out in Es-Salem reactor. The experimental procedure and the results are discussed. We noted during this work that the upper limit values for suspended dusts and the high concentrations for some toxic elements found are due to the weather conditions and intense road traffic around collecting sites. (authors)

2010-07-15

413

Solidification of radioactive waste effluents  

Energy Technology Data Exchange (ETDEWEB)

A process and apparatus for solidifying radioactive waste liquid containing dissolved and/or suspended solids is disclosed. The process includes chemically treating for pH adjustement and precipitation of solids, concentrating solids with a thin-film evaporator to provide liquid concentrate containing about 50% solids, and drying the concentrate with heated mixing apparatus. The heated mixing apparatus includes a heated wall and working means for shearing dried concentrate from internal surfaces and subdividing dry concentrate into dry, powdery particles. The working means includes a rotor and helical means for positively advancing the concentrate and resulting dry particles from inlet to outlet of the mixing apparatus. The dry particles may also be encapsulated in a matrix material. Entrained particles in the vapor stream from the evaporator and mixer are removed in an integral particle separator and the vapor is subsequently condensed and may be recycled upstream ...

1983-10-11

414

Sediment trap fluxes and benthic recycling of organic carbon, polycyclic aromatic hydrocarbons, and polychlorobiphenyl congeners in Lake Superior  

Energy Technology Data Exchange (ETDEWEB)

Sediment trap fluxes of solids, organic carbon, polycyclic aromatic hydrocarbons (PAHs), and polychlorinated biphenyls (PCBs) were measured in Lake Superior in 1984 and 1985. Mass fluxes from surface waters ranged from 0.14 to 1.1 g/m{sup 2}{center dot}day and increased near the lake floor due to resuspension of surficial sediment and horizontal transport in the benthic nepheloid layer. Organic matter fluxes from surface water ranged from 60 to 90 mg of C/m{sup 2}{center dot}day, with {approximately}5% of organic carbon settling from surface waters accumulating in bottom sediments. Concentrations of PCBs and PAHs are enriched 10-100 times on settling particles relative to those on suspended particles. Resultant settling fluxes are 10-100 times greater for several PCB and PAH compounds than net accumulation rates in bottom sediments, indicating the effective and rapid recycling in the benthic region. Biological packaging of organic pollutants into rapidly settling ...

1991-03-01

415

Role of E-cadherin in the induction of apoptosis of HPV16-positive CaSki cervical cancer cells during multicellular tumor spheroid formation  

British Library Electronic Table of Contents (United Kingdom)

Multicellular tumor spheroids (MCTS) are three dimensional cell culture systems induced by suspension culture. MCTS are widely used in cancer research because of their similarity to solid tumors. CaSki cells are derived from a metastatic cervical cancer containing human papillomavirus 16 (HPV16). Cell death of CaSki cells in MCTS has been previously reported, and our model is used to better characterize the mechanisms of cell death of HPV16-positive keratinocytes. In this study, we found that apoptosis of CaSki cells was induced by suspension culture along with the formation of MCTS after 24?h of incubation. In suspended CaSki cells, monoclonal antibodies blocking E-cadherin function inhibited MCTS formation and suppressed suspension-induced apoptosis in a dose-dependent manner. Western bl...

2008-01-01

416

Results of the Virgo central interferometer commissioning  

International Nuclear Information System (INIS)

The interferometric gravitational wave detector Virgo has successfully completed the first major step of its commissioning. It consists of a Michelson interferometer with 6 m arms with suspended mirrors. The interferometer is tuned to the dark fringe with a recycling mirror on the other port (bright fringe) to form an equivalent 12 m long Fabry-Perot cavity. This setup has allowed us to validate the major technology choices that have been made: passive seismic attenuators, a light source with a long mode cleaner, many analogue and digital servo loops, control software, high speed data acquisition system. A sensitivity of 8 x 10"-"1"7 m Hz"-"1"/"2 at 1 kHz together with a duty cycle of 80% has been attained during a 72 h engineering run. The data analysis allowed us to understand the noise contributions, and several improvements have been carried out while proceeding with the end of the installation of vacuum tubes and the remaining suspensions, and before starting ...

2004-03-07

417

Residential runoff as a source of pyrethroid pesticides to urban creeks.  

Science.gov (United States)

Pyrethroid pesticides occur in urban creek sediments at concentrations acutely toxic to sensitive aquatic life. To better understand the source of these residues, runoff from residential neighborhoods around Sacramento, California was monitored over the course of a year. Pyrethroids were present in every sample. Bifenthrin, found at up to 73 ng/L in the water and 1211 ng/g on suspended sediment, was the pyrethroid of greatest toxicological concern, with cypermethrin and cyfluthrin of secondary concern. The bifenthrin could have originated either from use by consumers or professional pest controllers, though the seasonal pattern of discharge from the drain was more consistent with professional use as the dominant source. Stormwater runoff was more important than dry season irrigation runoff in transporting pyrethroids to urban creeks. A single intense storm was capable of discharging as much bifenthrin to an urban creek in 3h as that discharged over 6 months of ...

2008-08-03

418

Residential runoff as a source of pyrethroid pesticides to urban creeks  

International Nuclear Information System (INIS)

Pyrethroid pesticides occur in urban creek sediments at concentrations acutely toxic to sensitive aquatic life. To better understand the source of these residues, runoff from residential neighborhoods around Sacramento, California was monitored over the course of a year. Pyrethroids were present in every sample. Bifenthrin, found at up to 73 ng/L in the water and 1211 ng/g on suspended sediment, was the pyrethroid of greatest toxicological concern, with cypermethrin and cyfluthrin of secondary concern. The bifenthrin could have originated either from use by consumers or professional pest controllers, though the seasonal pattern of discharge from the drain was more consistent with professional use as the dominant source. Stormwater runoff was more important than dry season irrigation runoff in transporting pyrethroids to urban creeks. A single intense storm was capable of discharging as much bifenthrin to an urban creek in 3 h as that discharged over 6 months of ...

2009-01-01

419

Recent historical changes on the Belgian Meuse  

International Nuclear Information System (INIS)

When a nuclear power station was installed on the Meuse in central Belgium, the impact of thermal, radioactive, and chemical waste on the water of the Neuse and on its biocenoses was studied. Three successive periods of development of the channel bed and the flood plain in Belgium have occurred, and their hydrological, physicochemical, and ecological consequences have been examined. Since the last century, the ecosystem of the Meuse has undergone, due to the increasing activity of man, modifications of increasing importance: marked reduction of the water flow, a drastic increase in the suspended material being transported, a degree of eutrophication of the water, and the disturbance of the original floral and faunal communities. The causes of this evolution of the Meuse can be itemized as different types of human interference in descending order of importance: (1) occupation of the catchment area; (2) encroachment on the flood plain; (3) encroachment on the channel ...

420

Influence of suspended solids on pitting corrosion of carbon steel in cooling water. Tansoko no koshoku ni oyobosu reikyaku suichu no kendaku busshitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion enlarging the rust due to its deposition near the anode. Since only the inhibitor is not sufficient to inhibit the pitting corrosion under the existence ...

1993-08-15

421

Homotopy Normal Maps  

CERN Document Server

Normal maps between discrete groups $N\\rightarrow G$ were characterized[FS] as those which induce a compatible topological group structure on the homotopy quotient $EN\\times_N G$. Here we deal with topological group maps $N\\rightarrow G$ being normal in the same sense as above and hence forming a homotopical analogue to the inclusion of a topological normal subgroup in a reasonable way. We characterize these maps by a compatible simplicial loop space structure on $Bar_\\bullet(N,G)$, invariant under homotopy monoidal functors, e.g. Localizations and Completions. In the course of characterizing homotopy normality, we define a notion of a "homotopy action" similar to an $A_{\\infty}$ action on a space, but phrased in terms of Segal's 'special $\\Delta-$spaces' and seem to be of importance on its own right. As an application of the invariance of normal maps, we give a very short proof to a theorem of Dwyer and Farjoun namely that a localization by a suspended map ...

2010-01-01

422

High performance fiber filtration and its fluid flow  

Energy Technology Data Exchange (ETDEWEB)

A new filtration process using acrylic fiber has been developed which has wide applications in water works, sewage water treatment and waste water treatment facilities. Instead of sand, the common filter media in conventional systems, this new system uses long, fine acrylic fibers. Compared with a conventional system, the filtration speed and suspended solids (SS) retention of the new system have been increased 500% from 120--200 m/d to 400--1,200 m/d and from 2--3 kg/m{sup 2} to 5--20 kg/m{sup 2}, respectively. In addition, the backwash time has been decreased 60%, from 20--30 min to 10 min. As SS retention increase, the empty space between the fibers (fiber void) decreases and pressure drops due to the high filtration rate. Thus the pressure decreases rapidly after a certain period of filtration because of the increased SS retention cause fiber compression. This system is primarily based on solution clarification, but differs in that the fiber filter`s head loss ...

1994-12-31

423

Emissions Inventory Report Summary: Reporting Requirements for the New Mexico Administrative Code, Title 20, Chapter 2, Part 73 (20 NMAC 2.73) for Calendar Year 2001  

Energy Technology Data Exchange (ETDEWEB)

Los Alamos National Laboratory is subject to annual emissions-reporting requirements for regulated air contaminants under Title 20 of the New Mexico Administrative Code, Chapter 2, Part 73 (20.2.73 NMAC), Notice of Intent and Emissions Inventory Requirements. The applicability of the requirements is based on the Laboratory's potential to emit 100 tons per year of suspended particulate matter, nitrogen oxides, carbon monoxide, sulfur oxides, or volatile organic compounds. For calendar year 2001, the Technical Area 3 steam plant was the primary source of criteria air pollutants from the Laboratory, while research and development activities were the primary source of volatile organic compounds. Emissions of beryllium and aluminum were reported for activities permitted under 20.2.72 NMAC. Hazardous air pollutant emissions from chemical use for research and development activities were also reported.

2003-04-01

424

Characteristics of volatile fatty acid decomposition in anaerobic fluidized bed  

Energy Technology Data Exchange (ETDEWEB)

The growth kinetics constants and concentration of active attached biomass in an anaerobic fluidized bed which decomposes acetic, propionic and butyric acid were estimated. The mixture of above mentioned fatty acids was supplied to the fluidized bed in the range of hydraulic retention time (HRT) from 0.25 to 2 days. After the effluent reached in a steady state in quality, batch experiments were conducted separately with each fatty acid as a substrate in order to investigate the decomposition characteristics of each substrate by attached biomass. In order to estimate the parameter values of the growth kinetics of the bacteria, batch experiments were also conducted under the completely mixed condition using detached biomass from a support material. The changes of fatty acid concentrations with time were clearly expressed with the Monod growth model. Maximum specific substrate decomposition rates and saturation constants, and active biomass concentrations were obtained by the curve ...

1988-06-01

425

Analytical surveys on water quality of Trasimeno Lake: Definition of trophic levels; Indagine sulla qualita` delle acque del Lago Trasimeno: Definizione dei livelli trofici  

Energy Technology Data Exchange (ETDEWEB)

The previous judgment of eutrophic state, once proposed for the Trasimeno Lake (Umbria region, Italy), has been revised. According to Vollenweider-OECD classification criterion, the lake waters are at present to be classified as mesotrophic waters, with phosphorus limitation. However this level of moderate productivity results to be conditioned by the hydrochemical characteristics of the lake waters, that control phosphorus concentrations independently from the loading coming from the basin, and prevent dangerous and massive algal blooms. Different processes of chemical nature, regulating the phosphorus amount in the lake waters, are then reviewed: adsorption of P/P0(4) onto suspended materials, particularly clay mineral particles, and direct precipitation as hydroxylapatite or co-precipitation with carbonates, are found to be the principal mechanisms that determine chemical removal of phosphorus from the water column. A preliminary mass balance of phosphorus ...

1995-06-01

426

Anaerobic treatment of wastewater from a food-manufacturing plant with a low concentration of organic matter and regeneration of usable pure water  

Energy Technology Data Exchange (ETDEWEB)

Wastewater from a food-manufacturing plant with a low concentration of organic matter was treated at 37 centigrade in an anaerobic fluidized-bed reactor or in an upflow anaerobic sludge blanket. As the influent TOC (total organic carbon) concentration decreased, the TOC removal efficiency in these reactors decreased from 85% to 65%. The concentration of suspended solids in the effluent could be reduced to 20 mg/l, which corresponded to 7% of that in the influent. The effluent from both reactors was treated aerobically in a fixed-bed reactor. The TOC concentration and optical density of effluent from the aerobic treatment were reduced to 5 mg/l and 0.005, respectively. When the effluent treated anaerobically or aerobically was passed over an activated carbon column, the effluent TOC concentration was reduced to 2 to 3 mg/l. The conductivity in raw wastewater was remarkably reduced on an ion-exchange resin column. Ultra-pure water for industrial use was obtained by ...

1994-03-25

427

Aerodynamic force measurement on a large-scale model in a short duration test facility  

International Nuclear Information System (INIS)

A force measurement technique has been developed for large-scale aerodynamic models with a short test time. The technique is based on direct acceleration measurements, with miniature accelerometers mounted on a test model suspended by wires. Measuring acceleration at two different locations, the technique can eliminate oscillations from natural vibration of the model. The technique was used for drag force measurements on a 3 m long supersonic combustor model in the HIEST free-piston driven shock tunnel. A time resolution of 350 #mu#s is guaranteed during measurements, whose resolution is enough for ms order test time in HIEST. To evaluate measurement reliability and accuracy, measured values were compared with results from a three-dimensional Navier-Stokes numerical simulation. The difference between measured values and numerical simulation values was less than 5%. We conclude that this measurement technique is sufficiently reliable for measuring aerodynamic force ...

2005-03-01

428

Accelerated stability test techniques for middle distillate fuels  

Energy Technology Data Exchange (ETDEWEB)

Improved test techniques are needed for evaluating the inherent stability of middle distillate fuels both in surveillance and in procurement activities. A project was initiated to define and evaluate the contributing conditions leading to the formation of deleterious products in accelerated aging tests of middle distillate fuels and to relate these results to an experimental definition of more repeatable/reliable middle distillate fuel stability test technique(s). A literature search was conducted to provide a list of stability test techniques and their interpretations which could be used in a correlative middle distillate fuel stability test program. For this program, seven accelerated stability tests were chosen and evaluated using a set of six test fuels. The test techniques were selected to represent a wide variety of test conditions, including temperature, aging time, and oxygen availability. These six test fuels were purposely chosen to represent a wider range of stabilities than ...

1981-01-01

429

"Spin" and "Orbital" Flows in a Circularly Polarized Paraxial Beam: Orbital Rotation without Orbital Angular Momentum  

CERN Document Server

In light beams with circular or elliptic polarization, the transverse energy flow consists of the "spin" and "orbital" parts. Both of them can induce the orbital motion of microparticles suspended within the field of a light beam, and this should be taken into account in experiments on the spin-to-orbital angular momentum conversion. The character of the spin, orbital and total transverse energy flows in circular Laguerre-Gaussian beams is studied analytically; graphical representations of the flows in the beam cross section (flow maps) are calculated and analyzed. The spin circulatory flow can be directed oppositely to the orbital one and/or to the polarization handedness. As a result, the total transverse energy circulation of a beam with homogeneous circular polarization can be of different handedness in different regions of the beam cross section, which are separated by the contours of zero transverse energy flow. Regarding the particle position within the beam ...

2009-01-01

430

Magnetic properties of laminated perovskite-like ferroelectromagnetics  

International Nuclear Information System (INIS)

Magnetic properties of layer ferromagnets against the thickness are investigated. Two new compounds served for studies: Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1. The Moessbauer effect and the magnetic susceptibility measurements were applied in the experiment. The Faraday method was used in magnetic measurements in fields from 1 to 9,5 kOe. The results of Moessbauer measurements show that temperature dependence of the spectra is typical for compounds with superparamagnetic properties. The magnetic fields Hsub(n) on Fe"5"7 nuclei in Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1 are similar and equal to 520+-10 kOe. Therefore it may be concluded that relaxation times of nuclear spins in these compounds are equal or close to each other. The lines of quadrupole splitting appear in spectra together at 20 K. The results of magnetic ...

1975-01-01

431

Upgrade of X-ray Magnetic Diffraction Experimental System and Its Application to Ferromagnetic Material  

International Nuclear Information System (INIS)

We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to saturate the ...

2007-01-19

432

Ramp-rate sensitivity of SSC dipole magnet prototypes  

Energy Technology Data Exchange (ETDEWEB)

One of the major achievements of the magnet R&D program for the Superconducting Super Collider (SSC) is the fabrication and test of a series of 20 5-cm aperture, 15-m long dipole magnet prototypes. The ramp rate sensitivity of these magnets appears to fall in at least two categories that can be correlated to the manufacturer and production batch of the strands used for the inner-coil cables. The first category, referred to as type-A, is characterized by a strong quench current degradation at high ramp rates, usually accompanied by large distortions of the multipole fields and large energy losses. The second category, referred to as type-B, is characterized by a sudden drop of quench current at low ramp rates, followed by a much milder degradation at larger rates. The multipole fields of the type-B magnets show little ramp-rate sensitivity, and the energy losses are smaller than for the type-A ...

1994-07-01

433

Magnetization and 61Ni Moessbauer effect study of the ternary arsenide CrNiAs  

International Nuclear Information System (INIS)

The results of x-ray diffraction, dc magnetization, and 61Ni Moessbauer spectroscopy studies of the ternary arsenide CrNiAs are reported. This compound crystallizes in the orthorhombic Fe2P-type structure (space group P6-bar2m) with the lattice parameters a 6.1128(2) A and c = 3.6585(1) A. CrNiAs is a mean-field ferromagnet with Curie temperature TC = 171.9(1) K and the critical exponents ? 0.514(18), ? = 1.010(16), and ? = 2.922(10). The temperature dependence of the magnetic susceptibility above TC follows the modified Curie-Weiss law with a paramagnetic Curie temperature of 176.0(3) K and effective magnetic moment per transition metal atom of 2.42(1) ?B. The magnetic moment per formula unit at 4.2 K is found to be 1.114(33) ?B. The hyperfine magnetic field at 61Ni nuclei at 4.2 K of 41.5(1.0) kOe implies that the Ni atoms carry a magnetic moment of 0.15(3) ...

2008-08-13

434

Magnetic microstructure of candidates for epitaxial dual Heusler magnetic tunnel junctions  

Energy Technology Data Exchange (ETDEWEB)

Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.

2009-05-15

435

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were ...

2001-04-01

436

Low-temperature properties of ternary magnetic rare-earth transition-metal germanides with the Sc sub 5 Co sub 4 Ge sub 10 -type structure  

Energy Technology Data Exchange (ETDEWEB)

DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque on the ...

1988-01-01

437

Low temperature properties of ternary magnetic rare earth transition metal germanides with the Sc/sub 5/Co/sub 4/Ge/sub 10/-type structure  

Energy Technology Data Exchange (ETDEWEB)

DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the crystal field torque ...

1988-07-01

438

Applications of Magnetic PsiDO Techniques to Space-adiabatic Perturbation Theory  

CERN Document Server

In this review, we show how advances in the theory of magnetic pseudodifferential operators (magnetic $\\Psi$DO) can be put to good use in space-adiabatic perturbation theory (SAPT). As a particular example, we extend results of [PST03] to a more general class of magnetic fields: we consider a single particle moving in a periodic potential which is subjectd to a weak and slowly-varying electromagnetic field. In addition to the semiclassical parameter $\\eps \\ll 1$ which quantifies the separation of spatial scales, we explore the influence of additional parameters that allow us to selectively switch off the magnetic field. We find that even in the case of magnetic fields with components in $C_b^{\\infty}(\\R^d)$, e. g. for constant magnetic fields, the results of Panati, Spohn and Teufel hold, i.e. to each isolated family of Bloch bands, there exists an ...

2010-01-01

439

Large perpendicular magnetic anisotropy of ultrathin Ru and Rh films on a NiAl(001) surface  

International Nuclear Information System (INIS)

Using the full potential linearized augmented plane wave (FLAPW) method, the magnetic properties of two-dimensional Ru and Rh monolayers (MLs) on a NiAl(001) surface have been investigated. It has been found that free standing one monolayer Ru and Rh films have ferromagnetic ground state with magnetic moments of 2.21 and 1.48 #mu#_B, respectively. The ferromagnetism is still observed even on a Ni terminated NiAl(001) surface, while no magnetic state is found on an Al terminated surface. The calculated magnetic moments of Ru and Rh atoms are 1.56 and 0.88 #mu#_B, respectively. In addition, an induced magnetic moment in surface Ni is observed. It has been found that the free standing Ru film has perpendicular magnetization to the film surface with a magnetocrystalline anisotropy (MCA) energy of 0.66 meV/atom, while an in-plane MCA energy of 0.37 meV/atom is ...

2010-10-27

440

Final technical report for ''Frontiers in Plasma Kinetic Theory''  

International Nuclear Information System (INIS)

This report summarizes the results and activities funded by this three-year award. The principal goal of this project was to determine the thermal conductivity in clusters of galaxies. Intracluster plasmas possess chaotic magnetic fields. Since charged particles are constrained to move primarily along magnetic field lines, the topology of intracluster magnetic fields slows particle diffusion relative to the non-magnetized case, thereby reducing the thermal conductivity. Our first approach to this problem was to employ the static-magnetic-field approximation. In reality, intracluster magnetic field lines are constantly moving, since they are advected by turbulent intracluster motions. The turbulent velocities, however, are much smaller than the rapid speeds of thermal electrons, which make the dominant contribution to the thermal conductivity. In the static-field ...

2007-02-01

441

Weak ferromagnets with integer and half-integer spin quantum numbers  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigations are presented which demonstrate that the weak ferromagnets are special materials of a larger group of magnets which exhibit two magnetic ordering structures. In weak ferromagnets the main order is antiferromagnetic with a small ferromagnetic component existing in addition. On the other hand, materials in which other combinations of the two basic ordering structures coexist are also known. Common to all these non-collinear spin structures is that the moment components of the two magnetic structures are orthogonal. In the weak ferromagnets this orthogonality manifests already in the paramagnetic phase as a crossover from an isotropic to an anisotropic susceptibility with respect to the applied magnetic field: at high temperatures the antiferromagnetic Curie-Weiss law of the total moment is observed while for T->Tc crossover to a second Curie-Weiss law due to the weak ...

2005-01-31

442

Status of 4-cm-aperture, 17-m-long SSC dipole magnet R D program at BNL  

Energy Technology Data Exchange (ETDEWEB)

Over the last year-and-a-half, several 4-cm-aperture, 17-m-long dipole magnet prototypes were built by Brookhaven National Laboratory (BNL) under contract with the Superconducting Super Collider (SSC) Laboratory. These prototypes are the last phase of a half-decade-long R D program, carried out in collaboration with Fermi National Accelerator Laboratory and Lawrence Berkeley Laboratory, and aimed at demonstrating the feasibility of the SSC main ring dipole magnets. They also prepare the way of the 5-cm-aperture dipole magnet program to be started soon. In this paper, we analyze the mechanical behavior of the BNL prototypes during cool-down and excitation, and we attempt to relate this behavior to the magnet features. The data reveal that the mechanical behavior is sensitive to the vertical collar-yoke interference, and that the magnets exhibited somewhat erratic changes in coil ...

1991-06-01

443

On the plasma rotation in a straight magnetized filter of a pulsed vacuum arc  

International Nuclear Information System (INIS)

In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is employed in the driving region to quantify the magnitude of the ...

2007-01-21

444

Laboratory Plasma Dynamos, Astrophysical Dynamos, and Magnetic Helicity Evolution  

CERN Document Server

The term ``dynamo'' means different things to the laboratory fusion plasma and astrophysical plasma communities. To alleviate the resulting confusion and to facilitate interdisciplinary progress, we pinpoint conceptual differences and similarities between laboratory plasma dynamos and astrophysical dynamos. We can divide dynamos into three types: 1. magnetically dominated helical dynamos which sustain a large scale magnetic field against resistive decay and drive the magnetic geometry toward the lowest energy state, 2. flow-driven helical dynamos which amplify or sustain large scale magnetic fields in an otherwise turbulent flow, and 3. flow-driven nonhelical dynamos which amplify fields on scales at or below the driving turbulence. We discuss how all three types occur in astrophysics whereas plasma confinement device dynamos are of the first type. Type 3 dynamos requires no ...

2006-01-01

445

LHC Magnet Tests Operational Techniques and Empowerment for Successful Completion  

CERN Document Server

The LHC magnet tests operation team developed various innovative techniques, particularly since early 2004, to complete the superconductor magnet tests by Feb. 2007. Overall and cryogenic priority handling, rapid on-bench thermal cycling, rule-based goodness evaluation on round-the-clock basis, multiple, mashed web systems are some of these techniques applied with rigour for successful tests completion in time. This paper highlights these operation empowerment tools which had a pivotal role for success. A priority handling method was put in place to enable maximum throughput from twelve test benches, having many different constraints. For the cryogenics infrastructure, it implied judicious allocation of limited resources to the benches. Rapid On-Bench Thermal Cycle was a key strategy to accelerate magnets tests throughput, saving time and simplifying logistics. First level magnet appraisal was developed ...

2007-01-01

446

Imaging magnetic domain structure in sub-500 nm thin film elements  

Energy Technology Data Exchange (ETDEWEB)

Magnetic imaging in the transmission electron microscope (TEM) has been used to examine submicron elements with the aim of discovering down to what element size complex domain patterns can form. The elements were squares, circles, triangles, and pentagons in the size range 100{endash}500 nm and were made from 36 nm Co films or 8 nm Ni{sub 80}Fe{sub 20} (NiFe) with in-plane magnetization. The magnetic domain structures in these elements were imaged at high resolution using the differential phase contrast imaging mode in a TEM. Nonuniform magnetization structures were seen in the images. Vortices were present at remanence in all shapes of 36-nm-thick Co elements down to 100 nm size and in circular NiFe elements down to 116 nm diameter. Triangular NiFe elements did not have a vortex state at remanence, instead the magnetization curved round within the element but did not achieve ...

2001-06-01

447

Ferroelectric and magnetic properties of Ho{sub 2}CuTiO{sub 6} double perovskite  

Energy Technology Data Exchange (ETDEWEB)

Ho{sub 2}CuTiO{sub 6} double pervoskite is synthesized by solid state reaction method and the phase formation was confirmed by X-ray diffraction. Ho{sub 2}CuTiO{sub 6} crystallizes in space group P63 cm and are isostructural in AMnO{sub 3} structure. We have investigated the effect of the presence of a magnetic ion (Ho{sup 3+}{approx}10.4{mu}{sub B}) in Ho{sub 2}CuTiO{sub 6}, on the magnetic properties, compared to that of an isostructural double perovskite containing Y-ion (non-magnetic), i.e., Y{sub 2}CuTiO{sub 6}. Magnetization measurements on Ho{sub 2}CuTiO{sub 6} showed paramagnetic moment of 0.026{mu}{sub B}/Ho at room temperature in an applied field of 7 T although no saturation is observed at room temperature, whereas, at 5 K, the paramagnetic moment was 0.3{mu}{sub B}/Ho in the same field. Since this compound is non-centrosymmetric, it is of interest to look into the possibility of realizing ...

2006-08-15

448

Element-selective thermal x-ray magnetic circular dichroism study through the magnetic compensation temperature of Ho{sub 6}Fe{sub 23}  

Science.gov (United States)

We present an x-ray magnetic circular dichroism (XMCD) study performed on both Ho{sub 6}Fe{sub 23} and Y{sub 6}Fe{sub 23} compounds as a function of the temperature. The combined analysis of both Fe K-edge and Ho L{sub 2,3}-edge XMCD spectra recorded through the magnetic compensation transition allows us to disentangle the thermal dependence of both Fe and Ho magnetic moments in Ho{sub 6}Fe{sub 23}. In addition, contributions from Ho ions to the Fe K-edge XMCD signals and, conversely, from Fe ions to the Ho L{sub 2,3}-edge XMCD spectra have been clearly identified. These extra contributions, arising from the strong Fe(3d)-Ho(5d) hybridization, have been isolated from the spectra and correlated with the magnetic state of both Ho and Fe ions surrounding the absorbing site. The influence of these contributions to the values of the orbital and spin moments derived by using sum rule analysis is also shown.

2005-09-01

449

Effect of Ho^3^+ substitutions on the structural and magnetic properties of BaFe12O19 hexaferrites  

British Library Electronic Table of Contents (United Kingdom)

Holmium doped barium based hexaferrites BaFe12-2xHo2xO19 with (x=0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho^3^+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (Ms), remanent magnetization (Mr) and coercivity (Hc) were observed by changing Ho^3^+ content in BaFe12-2xH...

2010-01-01

450

Effect of Ho"3"+ substitutions on the structural and magnetic properties of BaFe_1_2O_1_9 hexaferrites  

International Nuclear Information System (INIS)

Holmium doped barium based hexaferrites BaFe_1_2_-_2_xHo_2_xO_1_9 with (x = 0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho"3"+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (M_s), remanent magnetization (M_r) and coercivity (H_c) were observed by changing Ho"3"+ content in BaFe_1_2_-_2_xHo_2_xO_1_9 ferrites. Coercivity showed a maximum value of 2230 Oe for (x = ...

2010-04-09

451

Absorption Features in Spectra of Magnetized Neutron Stars  

CERN Document Server

The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the observations can be explained by a thin ...

2010-01-01

452

A novel semidry flue gas desulfurization process with the magnetically fluidized bed reactor.  

Science.gov (United States)

The magnetically fluidized bed (MFB) was used as the reactor in a novel semidry flue gas desulfurization (FGD) process to achieve high desulfurization efficiency. Experiments in a laboratory-scale apparatus were conducted to reveal the effects of approach to adiabatic saturation temperature, Ca/S molar ratio and applied magnetic field intensity on SO(2) removal. Results showed that SO(2) removal efficiency can be obviously enhanced by decreasing approach to adiabatic saturation temperature, increasing Ca/S molar ratio, or increasing applied magnetic field intensity. At a magnetic field intensity of 300Oe and a Ca/S molar ratio of 1.0, the desulfurization efficiency (excluding desulfurization efficiency in the fabric filter) was over 80%, while spent sorbent appeared in the form of dry powder. With the SEM, XRD and EDX research, it can be found that the increase of DC magnetic field ...

2009-03-18

453

A DRAMATICALLY REDUCED SIZE IN THE GANTRY DESIGN FOR THE PROTON-CARBON THERAPY.  

Energy Technology Data Exchange (ETDEWEB)

Gantries in the proton/carbon cancer therapy machines represent the major cost and are of the largest size. This report explains a new way to the gantry design. The size and cost of the gantries are reduced and their use is simplified by using the fixed magnetic field. The ''new'' gantry is made of a very large momentum acceptance non-scaling Fixed Field Alternating Gradient (FFAG) quarter and half arc beam lines. The gantry is made of combined function magnets with a very strong focusing and small dispersion function. Additional magnets with a fast response are required to allow adjustments of the beam position for different energies at the beginning of the gantry. Additional strong focusing magnets following the gantry have also to be adjustable to provide required spot size and radial scanning above the patients. The fixed field combined function ...

2006-06-23

454

Valence transition and magnetic ordering in Sn doped EuPd/sub 2/Si/sub 2/  

Energy Technology Data Exchange (ETDEWEB)

The sharp, temperature induced, continuous valence transition in EuPd/sub 2/Si/sub 2/ is drastically changed by doping with Sn at the Si site up to 5 at.%. Only a first order valence transition occurs for a 3% Sn doped sample and the 2/sup +/ component which survives the valence transition orders magnetically at 4.2 K. No valence transition at all occurs for a 5% Sn doped sample right up to 1.9 K and magnetic ordering sets in around 30 K.

1983-12-01

455

Towards a realistic model of Fe-Cu-Fe spin valve systems using tight-binding methods  

Energy Technology Data Exchange (ETDEWEB)

Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.

1996-12-31

456

Toward the production of 50 000 tonnes of low-carbon steel sheet for the LHC superconducting dipole and quadrupole magnets  

CERN Document Server

A total of 50 000 tonnes of low-carbon steel sheet has been ordered for the LHC main magnets. After three years of production, about 10 000 tonnes of steel sheet have been produced by Cockerill-Sambre Groupe Usinor. This paper gives a summary of the manufacturing process and improvements implemented as well as an overview of the difficulties encountered during this production. Preliminary statistics obtained for the mechanical and magnetic steel properties are presented. (6 refs).

2002-01-01

457

Superconducting magnetic and inertial energy pulsed power systems  

International Nuclear Information System (INIS)

Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.

1975-07-15

458

Spontaneous radiation of an electron beam in a free-electron laser with a quadrupole wiggler  

Energy Technology Data Exchange (ETDEWEB)

A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.

1986-09-01

459

Radiation and thermal analysis of superconducting quadrupoles in the interaction region of linear collider  

Energy Technology Data Exchange (ETDEWEB)

CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.

2008-06-01

460

Preparation of NiZn-ferrite nanofibers by electrospinning for DNA separation  

Energy Technology Data Exchange (ETDEWEB)

We present the synthesis, magnetic and UV spectrometry of NiZn-ferrite nanofiber. The single phase of spinel ferrite was obtained at 600 {sup o}C. The NiZn-ferrite fibers fabricated by an electrospinning process were formed as a polygonal grain growth with firing temperature in fiber matrix. It appeared that the saturation magnetization (M{sub S}) of NiZn-ferrite nanofiber was dependent on Ni/Zn molar ratio which is similar to that of the inverse spinel ferrites. The NiZn-ferrite fibers showed good DNA adsorption efficiency that can be modified and utilized for DNA separation with magnetic nanofiber as a novel material in clinical applications.

2009-05-15

461

Peristaltic flow of a couple stress fluid under the effect of induced magnetic field in an asymmetric channel  

Energy Technology Data Exchange (ETDEWEB)

The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters. (orig.)

2011-01-15

462

Peristaltic flow of a couple stress fluid under the effect of induced magnetic field in an asymmetric channel  

British Library Electronic Table of Contents (United Kingdom)

The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters.

2011-01-01

463

On the magnetic behaviour of REBa_2F_7 compounds (RE=Eu, Dy, Ho, Er, Tm and Yb)  

International Nuclear Information System (INIS)

The DC magnetic susceptibility of the REBa_2F_7 compounds was measured by a SQUID magnetometer in the temperature range 5-300 K. Except for Eu, the other compounds show either Curie law or Curie-Weiss law with relatively small values of paramagnetic Curie temperature, #theta#_p, with effective magnetic moments in the range expected of electronic ground state of the trivalent rare earth ion with appropriate J value. The behaviour of Eu is complex. (orig.).

464

On the Bottom Magnetic Fields of the Millisecond Pulsars  

CERN Document Server

The magnetic field strengths of most millisecond pulsars(MSP) are about $10^{8-9}$ Gauss. The accretion induced magnetic field evolution scenario here concludes that the field decay is invesely related to the accreted mass and the minimum field or bottom field stops at about $10^{8}$ Gauss if accreted with the Eddington accretion rate, which is proportionally related with the accretion rate as $\\dot{M}^{1/2}$. The possibility of the low field $\\sim 10^{7}$ Gauss MSPs has been proposed for the future radio observation.

2003-01-01

465

Magneto thermal convection in a compressible couple-stress fluid  

Energy Technology Data Exchange (ETDEWEB)

The problem of thermal instability of compressible, electrically conducting couple-stress fluids in the presence of a uniform magnetic field is considered. Following the linearized stability theory and normal mode analysis, the dispersion relation is obtained. For stationary convection, the compressibility, couple-stress, and magnetic field postpone the onset of convection. Graphs have been plotted by giving numerical values of the parameters to depict the stability characteristics. The principle of exchange of stabilities is found to be satisfied. The magnetic field introduces oscillatory modes in the system that were non-existent in its absence. The case of overstability is also studied wherein a sufficient condition for the non-existence of overstability is obtained. (orig.)

2010-03-15

466

Magnetic behavior in defect-perovskites RTa{sub 3}O{sub 9} (R=Nd,Eu and Ho)  

Energy Technology Data Exchange (ETDEWEB)

Magnetic behavior in three compounds RTa{sub 3}O{sub 9} (R = Nd, Eu and Ho) with defect-perovskite structures has been investigated by DC magnetic susceptibility. The susceptibility of NdTa{sub 3}O{sub 9} shows strong influence of crystal field. For EuTa{sub 3}O{sub 9} a typical Van Vleck paramagnetism has been observed. HoTa{sub 3}O{sub 9} obeys a Curie-Weiss law above 20 K. (orig.) 8 refs.

1998-01-01

467

Magnetic and transport properties of Pr_2Pd_3Si_5  

International Nuclear Information System (INIS)

The results obtained from the magnetization, specific heat and electrical resistivity measurements on a polycrystalline sample of Pr_2Pd_3Si_5 are reported. The temperature dependence of magnetic susceptibility at low field (0.01 T) exhibits pronounced anomaly below 7 K due to antiferromagnetic ordering. The electrical resistivity and specific heat data also exhibit sharp transition at 6.6 K evidencing the onset of antiferromagnetic order. A fit to the electrical resistivity data below 6 K suggests the presence of an energy gap in magnon spectrum in the ordered state. (author)

2008-12-16

468

MITL - A 2-D code to investigate electron flow through non-uniform field region of magnetically insulated transmission lines  

Science.gov (United States)

Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.

1979-01-01

469

Fitting the fully coupled ORM for the Fermilab Booster  

Energy Technology Data Exchange (ETDEWEB)

The orbit response matrix (ORM) method [1] is applied to model the Fermilab Booster with parameters such as the BPM gains and rolls, and parameters in the lattice model, including the gradient errors and magnets rolls. We found that the gradients and rolls of the adjacent combined-function magnets were deeply correlated, preventing full determination of the model parameters. Suitable constraints of the parameters were introduced to guarantee an unique, equivalent solution. Simulations show that such solution preserves proper combinations of the adjacent parameters. The result shows that the gradient errors of combined-function magnets are within design limits.

2005-05-01

470

Finite element stress analysis of the CMS magnet coil  

CERN Document Server

The Compact Muon Solenoid (CMS) is one of the experiments which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN. The design field of the CMS magnet is 4 T, the magnetic length is 12.38 m and the aperture is 6.36 m. This is achieved with a 4 layer-5 module superconducting Al-stabilized coil energised at a nominal current of 20 kA. The finite element analysis (FEA) carried out is axisymmetric elasto-plastic. FEA has also been carried out on the suspension system and on the conductor. (8 refs).

2000-01-01

471

Electron paramagnetic resonance of nitroxide-doped magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.

2002-11-01

472

Design of a 2 T multipole wiggler insertion device for the SRS  

International Nuclear Information System (INIS)

Two new identical insertion devices have been designed for the Daresbury SRS. They are 2T permanent-magnet multipole wigglers that will provide high flux in the X-ray region. This paper describes the magnetic and mechanical design of the arrays of steel pole pieces and permanent-magnet blocks. Also given is the engineering design of the support structure that will cope with the very large forces present while maintaining high levels of precision in gap setting and parallelism. The engineering design has been fully assessed using finite-element techniques to predict the deflections of critical parts of the structure. These two devices are due to be installed into the SRS by the end of 1998.

1998-05-01

473

Controllable growth and magnetic properties of nickel nanoclusters electrodeposited on the ZnO nanorod template  

International Nuclear Information System (INIS)

The ZnO nanorods were used as a template to fabricate nickel nanoclusters by electrodeposition. The ZnO nanorod arrays act as a nano-semiconductor electrode for depositing metallic and magnetic nickel nanoclusters. The growth sites of Ni nanoclusters could be controlled by adjusting the applied potential. Under -1.15 V the Ni nanoclusters could be grown on the tips of ZnO nanorods. On increasing the potential to be more negative the ZnO nanorods were covered by Ni nanoclusters. The magnetic properties of the electrodeposited Ni nanoclusters also evolved with the applied potentials.

2009-12-09

474

Comments on open-ended magnetic systems for fusion  

Energy Technology Data Exchange (ETDEWEB)

Differentiating characteristics of magnetic confinement systems having externally generated magnetic fields that are open'' are listed and discussed in the light of their several potential advantages for fusion power systems. It is pointed out that at this stage of fusion research high-Q'' (as deduced from long energy confinement times) is not necessarily the most relevant criterion by which to judge the potential of alternate fusion approaches for the economic generation of fusion power. An example is given of a hypothetical open-geometry fusion power system where low-Q operation is essential to meeting one of its main objectives (low neutron power flux).

1990-09-24

475

Combined effect of magnetic field and thermal dispersion on a non-darcy mixed convection  

British Library Electronic Table of Contents (United Kingdom)

This paper is devoted to investigate the influences of thermal dispersion and magnetic field on a hot semi-infinite vertical porous plate embedded in a saturated Darcy-Forchheimer-Brinkman porous medium. The coefficient of thermal diffusivity has been assumed to be the sum of the molecular diffusivity and the dynamic diffusivity due to mechanical dispersion. The effects of transverse magnetic field parameter (Hartmann number Ha), Reynolds number Re (different velocities), Prandtl number Pr (different types of fluids) and dispersion parameter on the wall shear stress and the heat transfer rate are discussed.

2011-01-01

476

Automated purification of Borrelia burgdorferi s.l. PCR products with KingFisher"T"M magnetic particle processor prior to genome sequencing  

International Nuclear Information System (INIS)

Borrelia burgdorferi sensu lato genospecies were differentiated by PCR-based sequencing of the borrelial flagellin gene. To evaluate the usefulness of KingFisher"T"M magnetic particle processor in PCR product purification, borrelia PCR products were purified with KingFisher"T"M magnetic particle processor prior to cycle sequencing and the quality of the sequence data received was analyzed. KingFisher was found to offer a rapid and reliable alternative for borrelial PCR product purification.

477

A. C. losses in the SSC high energy booster dipole magnets  

Energy Technology Data Exchange (ETDEWEB)

The baseline design for the SSC High Energy Booster (HEB) has dipole bending magnets with a 50 mm aperture. An analysis of the cryogenic heat load due to A.C. losses generated in the HEB ramp cycle are reported for this magnet. Included in this analysis are losses from superconductor hysteresis, yoke hysteresis, strand eddy currents, and cable eddy currents. The A.C. loss impact of 2.5 {mu}m vs. 6 {mu}m filament conductor is presented. A 60 mm aperture design is also investigated. 8 refs., 3 tabs.

1991-06-01

478

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and a similar flow channel with an internal ...

1346-01-01

479

Towards Resonant-State THz Laser Based on Strained p-Ge ...  

Science.gov (United States)

... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...

2006-07-01

480

The Baikal Neutrino Telescope: Selected Physics Results  

CERN Document Server

We present results on searches for exotic particles (relativistic magnetic monopoles and WIMPs) and for UHE neutrinos, obtained with the Baikal neutrino telescope NT200.

2007-01-01

482

Spin-polarized Auger-electron diffraction study of the magnetic poisoning of Fe(001) by sulfur  

International Nuclear Information System (INIS)

Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.

483

REVIEW OF EXPLOSIVE (CHEMICAL) FORMING  

Science.gov (United States)

... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...

1965-04-01

484

Publications Reporting Innovations any Pu - NASA Technical Reports ...  

Science.gov (United States)

at present, some of which, like magnetic forming and hot-drape forming, are in experimental stages. NASA SP-5017 1965 52pp. GPO 40cents ...

485

NASA TM X-52248 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Magnetic Forming (10). - Forming of metals (the metal needs only to be an electrical conductor) is achieved without physical contact ...

486

NASA SPECIAL', PUBLICATIONS" - NASA Technical Reports Server  

Science.gov (United States)

ployed at present, some of which, like magnetic forming and hot-drape forming, are in experimental stages. NASA SP-5017 1965 52 pp. GPO 40 cents ...

487

Moessbauer investigation of the magnetic anisotropy and electronic structure of a metallic glass  

International Nuclear Information System (INIS)

The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).

488

Magnetism and recoilless fraction in metallic glasses after laser irradiation  

British Library Electronic Table of Contents (United Kingdom)

Samples of Fe78B13Si9 (Metglas 2605 TCA) and Fe77Cr2B16Si5 (Metglas 2605 S3A) were exposed to pulsed excimer laser irradiation at repetition rates of 15, 25 and 50Hz. The occurrence of out-of-plane magnetic anisotropy, changes in the average hyperfine magnetic field and width of the hyperfine field distribution were evidenced by transmission Mossbauer spectroscopy. The variation of the recoilless fraction with laser processing parameters was derived from the simultaneous recording of Mossbauer spectra using a stainless steel etalon as a dual absorber. Conclusions on the onset of long-range magnetic order were formulated.

2010-01-01

489

Impact of Ionospheric Scintillations on Space-Based ...  

Science.gov (United States)

... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...

1991-06-01

490

High Temperature Superconducting Compounds  

Science.gov (United States)

... Voltage noise power spectral density measurements as a function of temperature, frequency, current, and magnetic field on DyBa2Cu3O7.x (DBCO ...

1992-11-30

491

General Disclaimer One or more of the Following Statements may ...  

Science.gov (United States)

MAGNETIC FORMING BERYLLIUM COIL ASSEMBLY. By. J. W. Rogers, D. D. Wier, and M. E. Davis. Department of Electrical Engineering. Mississippi State University ...

492

Effects of velocity-dependent force on the magnetic form factors of odd-Z  

International Nuclear Information System (INIS)

We investigate the effects of the velocity-dependent force on the magnetic form factors and magnetic moments of odd-Z nuclei. The form factors are calculated with the harmonic-oscillator wavefunctions. It is found that the contributions of the velocity-dependent force manifest themselves in the very large momentum transfer region (q?4 fm-1). In the low and medium q region the contributions of the velocity-dependent force are very small compared with those without this force. However, in the high-q region the contributions of the velocity-dependent force are larger than the normal form factors. The diffraction structures beyond the existing experimental data are found after the contributions of the velocity-dependent force are included. The formula of the correction to the single particle magnetic moment due to the velocity-dependent force is reproduced exactly in the long-wavelength limit (q=0) of the M1 form factor. ...

2008-03-01

493

Eddy Current Flows Around Cracks in Thin Plates for ...  

Science.gov (United States)

... A few applications, such as magnetic forming and levitation, have exploited the dynamic force pro- ducing capability of eddy currents. ...

1981-03-01

494

EMFs: cutting through the controversy.  

UK PubMed Central (United Kingdom)

SOME SCIENTISTS ALLEGE that exposure to electric and magnetic fields generated by electric power delivery systems is responsible for certain cancers (particularly among children), reproductive dysfunction,...Full Text Available

1996-05-01

495

DISTORTION OF A MAGNETIC FIELD BY THE MOTION OF A ...  

Science.gov (United States)

... No. 52. Metal Complexew-I. Preparation and Physical Properties of Transition Metal Complexes of 6-Mercaptopurine and ,-Mercapto-6, 7-Diphenyl ...

1965-06-01

497

A Magnetic Suspension and Excitation System for Spin Vibration ...  

Science.gov (United States)

High Cycle Fatigue Initiative Workshop -Active Vibration. Control/Engine. Health Monitoring Session December 10,. 1996. The presentation was titled "Active ...