WorldWideScience
1

International Symposium on Magnetic Suspension Technology. Part 2  

International Nuclear Information System (INIS)

In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.

1991-08-19

2

Progress of magnetic-suspension systems and magnetic bearings in the USSR  

International Nuclear Information System (INIS)

This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.

1992-05-01

3

Study of Japanese electrodynamic-suspension maglev systems  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of a study of the Japanese MLU magnetic-levitation (maglev) system. The development of the MLU system is reviewed, and the dynamic circuit model then is introduced and applied to the figure-eight-shaped null-flux coil suspension system. Three different types of figure-eight-shaped null-flux suspension systems are discussed in detail: (1) the figure-eight-shaped null-flux coil suspension system without cross-connection; (2) the combined suspension and guidance system; and (3) the combined propulsion, levitation, and guidance system. The electrodynamic-suspension maglev systems developed in Japan seem to be very promising and could result in a commercial application in the near future.

1994-04-01

4

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

5

Non-linearity and hysteresis of Hall effect in magnetorheological suspensions with conducting carrier  

Energy Technology Data Exchange (ETDEWEB)

In this article a production method of a magnetorheological suspension composed with silicon steel particles of size 0.1-0.15 mm and 4% silicon content is described. Steel particles were dispersed in a conducting carrier of a by mixture of graphite particles with size 2-5 {mu}m and cedar wood oil. The filling factor of the suspension with the silicon steel particles and with graphite particles amounted to 0.25-0.40. Samples of this suspension were placed in a rectangular vessel with electrodes and used for the investigation of the Hall effect in magnetic field with induction 0-8 T, generated by Bitter-type magnet. A non-linear dependence of Hall voltage on the induction of the applied magnetic field and a hysteresis loop of this voltage in the shape of inclined digit eight were found. The causes of the observed effects is the ordering of silicon steel particles ...

2003-08-01

6

A Magnetic Suspension and Excitation System for Spin Vibration ...  

Science.gov (United States)

High Cycle Fatigue Initiative Workshop -Active Vibration. Control/Engine. Health Monitoring Session December 10,. 1996. The presentation was titled "Active ...

7

R and D on Control Rod Magnetic Suspension Drive Mechanism of CARR  

Energy Technology Data Exchange (ETDEWEB)

This paper deal with the research and develop (R and D) on Control Rod Magnetic Suspension Drive Mechanism (MSDM) of CARR. The MSDM is made up of tube, coil, armature, step motor, lead screw etc. The MSDM use electromagnetics as its main principle. The open solenoid electromagnet technique is employed to implement suspension function. It has advantages of high drive precision, high safety feature, good running reliability, easy maintenance and good economical property. The R and D process of MSDM has three phases including single coil electromagnet, principle prototype and engineering prototype. (author)

2011-07-01

8

Effect of Elicitation and Changes in Extracellular pH on the Cytoplasmic and Vacuolar pH of Suspension-Cultured Soybean Cells 1  

UK PubMed Central (United Kingdom)

We have employed both 31P nuclear magnetic resonance spectroscopy and two intracellular fluorescent pH indicator dyes to monitor the pH of the vacuole and cytoplasm of suspension-cultured...Full Text Available

1992-02-01

9

31P NMR Observations on the Effect of the External pH on the Intracellular pH Values in Plant Cell Suspension Cultures 1  

UK PubMed Central (United Kingdom)

31P nuclear magnetic resonance (NMR) spectroscopy was used to monitor the response of oil palm (Elaeis guineensis) and carrot (Daucus carota) cell suspensions...Full Text Available

1990-06-01

10

Density separation of materials by using magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic ...

1980-03-01

11

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in ...

2009-05-15

12

Magnetorheological suspension electromagnetic brake  

International Nuclear Information System (INIS)

The magnetorheological suspension (MRS) brake is of the monoblock type. The main part of the electromagnetic brake is an electromagnet, between whose poles two MRS disks are placed. For distances between disks of 0.65x10"-"3 m#+-#10%, revolutions of the electric motor, coupled to the electromagnetic brake, ranging between 200 and 1600 rev/min and braking powers of up to 85 W, there are no differences in revolutions between the disks of the electromagnetic brake. For fixed revolutions of the electric motor, the revolution of the parallel disk can be modified continuously by means of the intensity of the magnetic field. In all cases, the quantity of MRS is of 0.35x10"-"3 kg.

2004-04-01

13

An Advance in Superconducting Magnet Technology Opens the Door...  

Science.gov (United States)

magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...

2011-08-20

14

Finite element stress analysis of the CMS magnet coil  

CERN Document Server

The Compact Muon Solenoid (CMS) is one of the experiments which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN. The design field of the CMS magnet is 4 T, the magnetic length is 12.38 m and the aperture is 6.36 m. This is achieved with a 4 layer-5 module superconducting Al-stabilized coil energised at a nominal current of 20 kA. The finite element analysis (FEA) carried out is axisymmetric elasto-plastic. FEA has also been carried out on the suspension system and on the conductor. (8 refs).

2000-01-01

15

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

16

Thermal-physical analysis of low-radioactive thermonuclear plasma in the magnetic fusion device  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

18

Magnetic electronic lenses, quadrupole and octupole for microsystem electron beam techniques  

International Nuclear Information System (INIS)

The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered

2006-09-01

19

The possible detection of magnetic monopoles and monopole tachyons  

International Nuclear Information System (INIS)

This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.

20

Magnetic separation anxiety  

International Nuclear Information System (INIS)

This paper reports that only a few years ago superconducting magnetic separation was viewed as the next major market for superconducting magnets. The first commercial units had been installed, worked flawlessly, and demonstrated real economic viability. The potential market was seen as quite large, and many people believed that superconducting magnetic separation would soon show the same rapid growth that MRI had demonstrated after its initial success. These hopes even prompted IGC, one of the top MRI magnet builders, to form a separate division devoted to magnetic separation. Despite the existence of Magstream, IGC has not been overly active in the market. As a technology that has applications from the clay on the Earth to the soil on the moon, superconducting magnetic separation has yet to become widely used.

1992-01-01

21

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

22

Use of magnetic treatment to intensify certain processes in the refining of chemical products of coking  

Energy Technology Data Exchange (ETDEWEB)

The results of the investigations show that magnetic treatment is a quite practical and effective method of intensifying certain technological processes in the coking industry. Magnetic treatment was utilized for improving the production of ammonium sulfate, refining of the naphthalene fraction, removal of sludge from wash oil in the benzol division, and the treatment of tar before fractionation. 2 references, 3 tables.

1983-01-01

24

Decontamination of building surface using clay suspension  

Energy Technology Data Exchange (ETDEWEB)

The decontamination of the urban building surfaces, based on the covering of clay suspensions, has been studied. Contaminated samples for test purpose were prepared by application of radioactive solution which was extracted from the soil of 2 km zone of the Chernobyl Nuclear Power Plant(ChNPP). The cation converting conditions of clay suspensions were determined by the experiments of swelling and stability of the suspensions. According to the experimental results, the most effective clay suspension was the NH{sub 4}-type which had a 7.1 of decontamination factor(DF) on Cs and 4.5 of DF on total nuclides after 3 times covering on slate.

1994-07-01

25

Technical description of parameters influencing the pH value of suspension absorbent used in flue gas desulfurization systems.  

Science.gov (United States)

As a result of the large limestone deposits available in Poland, the low cost of reagent acquisition for the largescale technological use and relatively well-documented processes of flue gas desulfurization (FGD) technologies based on limestone sorbent slurry, wet scrubbing desulfurization is a method of choice in Poland for flue gas treatment in energy production facilities, including power plants and industrial systems. The efficiency of FGD using the above method depends on several technological and kinetic parameters, particularly on the pH value of the sorbent (i.e., ground limestone suspended in water). Consequently, many studies in Poland and abroad address the impact of various parameters on the pH value of the sorbent suspension, such as the average diameter of sorbent particles (related to the limestone pulverization degree), sorbent quality (in terms of pure calcium carbonate [CaCO3] content ...

2010-08-01

26

Development of magnetic separation system of magnetoliposomes  

Energy Technology Data Exchange (ETDEWEB)

The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm ...

2009-10-15

27

Industrial production of RHIC magnets  

Energy Technology Data Exchange (ETDEWEB)

RHIC 8 cm aperture dipole magnets and quadrupole cold masses are being built for Brookhaven National Laboratory (BNL) by Northrop Grumman Corporation at a production rate of one dipole magnet and two quadrupole cold masses per day. This work was preceded by a lengthy Technology Transfer effort which is described elsewhere. This paper describes the tooling which is being used for the construction effort, the production operations at each workstation, and also the use of trend plots of critical construction parameters as a tool for monitoring performance in production. A report on the improvements to production labor since the start of the programs is also provided. The magnet and cold mass designs, and magnetic test results are described in more detail in a separate paper.

1996-07-01

28

Magnetic liquefier for hydrogen  

Energy Technology Data Exchange (ETDEWEB)

This document summarizes work done at the Astronautics Technology Center of the Astronautics Corporation of America (ACA) in Phase 1 of a four phase program leading to the development of a magnetic liquefier for hydrogen. The project involves the design, fabrication, installation, and operation of a hydrogen liquefier providing significantly reduced capital and operating costs, compared to present liquefiers. To achieve this goal, magnetic refrigeration, a recently developed, highly efficient refrigeration technology, will be used for the liquefaction process. Phase 1 project tasks included liquefier conceptual design and analysis, preliminary design of promising configurations, design selection, and detailed design of the selected design. Fabrication drawings and vendor specifications for the selected design were completed during detailed design. The design of a subscale, demonstration ...

1992-12-31

29

Towards a realistic model of Fe-Cu-Fe spin valve systems using tight-binding methods  

Energy Technology Data Exchange (ETDEWEB)

Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.

1996-12-31

30

Superconducting magnetic and inertial energy pulsed power systems  

International Nuclear Information System (INIS)

Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.

1975-07-15

31

Radiation and thermal analysis of superconducting quadrupoles in the interaction region of linear collider  

Energy Technology Data Exchange (ETDEWEB)

CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.

2008-06-01

32

Reduction of Selenate to Selenide by Sulfate-Respiring Bacteria: Experiments with Cell Suspensions and Estuarine Sediments  

UK PubMed Central (United Kingdom)

Washed cell suspensions of Desulfovibrio desulfuricans subsp. aestuarii were capable of reducing nanomolar levels of selenate to selenide as well as sulfate to sulfide....Full Text Available

1987-06-01

33

Membrane filtration of food suspensions.  

UK PubMed Central (United Kingdom)

Factors affecting the membrane filtration of food suspensions were studied for 58 foods and 13 membrane filters. Lot number within a brand, pore size (0.45 or 0.8 micrometer), and time elapsed before...Full Text Available

1979-01-01

35

Engineering Technology Reports, Volume 2: Technology Base FY00  

Energy Technology Data Exchange (ETDEWEB)

In FY-2000, Engineering at Lawrence Livermore National Laboratory faced significant pressures to meet critical project milestones, and immediate demands to facilitate the reassignment of employees as the National Ignition Facility (the 600-TW laser facility being designed and built at Livermore, and one of the largest R&D construction projects in the world) was in the process of re-baselining its plan while executing full-speed its technology development efforts. This drive for change occurred as an unprecedented level of management and program changes were occurring within LLNL. I am pleased to report that we met many key milestones and achieved numerous technological breakthroughs. This report summarizes our efforts to perform feasibility and reduce-to-practice studies, demonstrations, and/or techniques--as structured through our technology centers. Whether using computational engineering to predict how giant ...

2001-10-03

36

Physical basis of the effect of hemoglobin on the "3"1P NMR chemical shifts of various phosphoryl compounds  

International Nuclear Information System (INIS)

The marked difference between the intra- and extracellular "3"1P NMR chemical shifts of various phosphoryl compounds when added to a red cell suspension may be largely understood in terms of the effects of hemoglobin on the "3"1P NMR chemical shifts. The presence of [oxy- or (carbonmonoxy)-] hemoglobin inside the red cell causes the bulk magnetic susceptibility of the cell cytoplasm to be significantly less than that of the external solution. This difference is sufficient to account for the difference in the intra- and extracellular chemical shifts of the two phosphate esters trimethyl phosphate and triethyl phosphate. However, in the case of the compounds dimethyl methylphosphonate, diethyl methylphosphonate, and trimethylphosphine oxide as well as the hypophosphite, phenylphosphinate, and diphenylphosphinate ions, hemoglobin exerts an additional, much larger, effect, causing the "3"1P NMR resonances to shift to lower frequency in a manner ...

37

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

38

Kinematics and flow characteristics of a magnetic actuated multi-cilia configuration  

British Library Electronic Table of Contents (United Kingdom)

The current paper continues the analysis of a completely novel method of fluid manipulation technology in micro-fluidics systems, inspired by nature, namely by the mechanisms found in ciliates. More information on this subject can be found at http://www.hitech-projects.com/euprojects/artic/. In order to simulate the drag forces acting on an array of artificial cilia, we have developed a computer code that is based on fundamental solutions of Stokes flow in a semi-infinite domain. The actuation mechanism consists of a bi-directional rotating excitation magnetic field. The magnetization induced by the magnetic field was calculated in a separate routine based on the Integral Nonlinear Equations Approach with 1D discretization of wire (cilium). Time averaged x-coordinate mass flow rates, strea...

2011-01-01

39

Solid suspension in stirred tanks: UVP measurements and CFD simulations  

British Library Electronic Table of Contents (United Kingdom)

Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.

2011-01-01

40

Fusion technology  

International Nuclear Information System (INIS)

The Fusion Technology task performs analyses and systems studies of conceptual fusion reactors based upon inertial and high-#beta# magnetic confinement schemes. Progress in the areas of theoretical analysis (plasma and neutral-gas blanket models), specific reactor studies (toroidal and linear theta pinches, Z pinches, laser fusion) neutronic and nuclear data assessments, materials (metals and insulators) evaluation, and general engineering design is reported.

1976-12-01

41

Influence of hormones and medium components on expression of dipyranocoumarins in cell suspension cultures of Calophyllum inophyllum L.  

British Library Electronic Table of Contents (United Kingdom)

Cell suspension cultures were initiated separately from leaf and nodal/internodal calluses for the study of influence of hormones and medium components on biomass growth and expression of dipyranocoumarins. Highest 6.2 times biomass was enhanced in suspension cultures of nodal/internodal callus supplemented with threefold total sulphate. Picloram 8.28mM along with BAP 8.88mM enhanced 295.05 times inophyllum A in suspension cultures of leaf callus whereas IBA 14.70mM along with BAP 4.44mM in suspension cultures of leaf callus enhanced 1065 times inophyllum B. IBA 4.90mM alone in suspension cultures of nodal/internodal callus enhanced maximum 616 times inophyllum C. Only IBA 9.80mM in suspension cultures of leaf callus enhanced 23.22 times inophyllum P. Variation in nitrate and sulphate had ...

2009-01-01

42

WIS decontamination factor demonstration test with radioactive nuclides  

Energy Technology Data Exchange (ETDEWEB)

A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10/sup 5/ for every nuclide, and from the results of above DF, over 10/sup 8/ is expected for real commercial plant as a total system. Therefore, it is realized that the off-gas clean up system of the WIS composed of ...

1987-04-01

43

WIS decontamination factor demonstration test with radioactive nuclides  

International Nuclear Information System (INIS)

A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10"5 for every nuclide, and from the results of above DF, over 10"8 is expected for real commercial plant as a total system. Therefore, it is realized that the off-gas clean up system of the WIS composed of only single ...

44

Results of the Virgo central interferometer commissioning  

International Nuclear Information System (INIS)

The interferometric gravitational wave detector Virgo has successfully completed the first major step of its commissioning. It consists of a Michelson interferometer with 6 m arms with suspended mirrors. The interferometer is tuned to the dark fringe with a recycling mirror on the other port (bright fringe) to form an equivalent 12 m long Fabry-Perot cavity. This setup has allowed us to validate the major technology choices that have been made: passive seismic attenuators, a light source with a long mode cleaner, many analogue and digital servo loops, control software, high speed data acquisition system. A sensitivity of 8 x 10"-"1"7 m Hz"-"1"/"2 at 1 kHz together with a duty cycle of 80% has been attained during a 72 h engineering run. The data analysis allowed us to understand the noise contributions, and several improvements have been carried out while proceeding with the end of the installation of vacuum tubes and the remaining suspensions, ...

2004-03-07

45

Bonding exterior grade structural panels with copolymer resins of biomass residue components, phenol, and formaldehyde  

Energy Technology Data Exchange (ETDEWEB)

Components of various forest and agricultural residue biomass-including the polyphenolic compounds-were converted into aqueous solution and/or suspension by extraction and digestion. Some biomass components reacted vigorously under alkaline catalysis with formaldehyde and initially showed a high degree of exothermic reaction; however, other components did not react as vigorously under these conditions, indicating that different biomass materials require different methods to obtain optimum reactivity for the copolymerization with phenol. Our primary goal is to develop adhesives capable of producing acceptable bond quality, as determined by the wood products industries` standards, under a reasonable range of gluing conditions. Copolymer resins of phenol, formaldehyde, and biomass components were synthesized and evaluated for gluability of bonding exterior grade structural replaced with chemicals derived from peanut hulls, pecan shell flour, pecan pith, southern pine ...

1993-12-31

46

Recent Energy Saving Technologies on Railway Traction Systems  

British Library Electronic Table of Contents (United Kingdom)

Energy saving technologies in the railway vehicle traction field can be mainly categorized into two domains: reducing loss and increasing the regenerative energy. Energy saving technologies for the traction equipment by the use of power converters with less loss and high-efficiency permanent magnet synchronous motors are introduced. The regenerative brake related technologies are also presented as another measure to save the energy, including the improvement of the regenerative brake control and application of energy storage devices. It is concluded that the benefit of the energy saving technology is not only the energy saving itself but also downsizing traction equipments and reducing the maintenance work in the electrical railway system. Copyright Copyright 2010 Institute of Electrical E...

2010-01-01

47

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high ...

2008-06-01

48

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, the authors are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. They are actively developing improved DC iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. They are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. They are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1988-03-01

49

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, we are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. We are actively developing improved dc iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. We are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. We are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1987-01-01

50

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

51

2D modeling and preliminary in vitro investigation of a prototype high gradient magnetic separator for biomedical applications.  

Science.gov (United States)

High gradient magnetic separation (HGMS) of magnetic materials from fluids or waste products has many established industrial applications. However, there is currently no technology employing HGMS for ex-vivo biomedical applications, such as for the removal of magnetic drug- or toxin-loaded spheres from the human blood stream. Importantly, human HGMS applications require special design modifications as, in contrast to conventional use where magnetic elements are permanently imbedded within the separation chambers, medical separators need to avoid direct contact between the magnetic materials and blood to reduce the risk of blood clotting and to facilitate convenient and safe treatment access for many individuals. We describe and investigate the performance of a magnetic separator prototype designed for biomedical applications. First, the ...

2007-03-30

52

A modular and extensible data acquisition and control system for testing superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into operation. This system utilizes a modular approach that provides both extensibility and ...

2001-07-20

53

The impact of solar flares and magnetic storms on humans  

International Nuclear Information System (INIS)

Three classes of solar emanations, namely, photon radiation from solar flares, solar energetic particles, and inhomogeneities in the solar wind that drive magnetic storms, are examined, and their effects on humans and technological systems are discussed. Solar flares may disrupt radio communications in the HF and VLF ranges. Energetic particles pose a special hazard at low-earth orbit and above, where they can penetrate barriers such as spacesuits and aluminum and destroy cells and solid state electronics. Energetic solar particles also influence terrestrial radio waves propagating through polar regions. Magnetic storms may disturb the operation of navigation instruments, power lines and pipelines, and satellites; they give rise to ionospheric storms which affect radio communication at all latitudes. There is also a growing body of evidence that changes in the geomagnetic field affect biological systems. 3 refs.

54

Establishing the limiting conditions of operation of magneto-rheological fluid dampers in vehicle suspension systems  

British Library Electronic Table of Contents (United Kingdom)

This paper deals with dynamical behavior of a nonlinear suspension system. We examine chaotic motion in a vehicle suspension system with hysteretic nonlinearity excited by a road profile. A one degree of freedom quarter-car model with nonsymmetric potential is investigated. The Melnikov criterion is used to study the intersection of stable and unstable manifolds and transition to chaos for the system. The condition for chaotic vibration is found using a Melnikov function. Chaotic motion also is indicated by a bifurcation diagram and Lyapunov exponents.

2009-01-01

55

A comparative analysis of passive twin tube and skyhook MRF dampers for motorcycle front suspensions  

Science.gov (United States)

A comparative analysis between conventional passive twin tube dampers and skyhook-controlled magneto-rheological fluid (MRF) dampers for motorcycle front suspensions is provided, based on single axis testing in a damper test rig and suspension performance testing in road trials. Performance motorcycles, while boasting extremely light suspension components and competition-ready performance, have an inherent weakness in comfort, as the suspension systems are designed primarily for racing purposes. Front suspension acceleration and shock loading transmit directly through the front suspension triple clamp into the rider's arms and shoulders, causing rapid fatigue in shoulder muscles. Magneto-rheological fluid dampers and skyhook control systems offer an alternative to conventional sport motorcycle suspensions - both performance and comfort can ...

2004-07-01

56

The market potential for SMES in electric utility applications. Final report  

Energy Technology Data Exchange (ETDEWEB)

Superconducting magnetic energy storage (SMES) is an emerging technology with features that are potentially attractive in electric utility applications. This study evaluates the potential for SMES technology in the generation, transmission, distribution, and use of electric energy; the time frame of the assessment is through the year 2030. Comparisons are made with other technology options, including both commercially available and advanced systems such as various peaking generation technologies, transmission stability improvement technologies, and power quality enhancement devices. The methodology used for this study focused on the needs of the market place, the capabilities of S and the characteristics of the competing technologies. There is widespread interest within utilities for the development of SMES technology, ...

1994-06-01

58

The Structure of Plant Cell Walls  

UK PubMed Central (United Kingdom)

The molecular structure, chemical properties, and biological function of the xyloglucan polysaccharide isolated from cell walls of suspension-cultured sycamore (Acer pseudoplatanus)...Full Text Available

1973-01-01

59

Synthesis and electrorheological characteristics of sea urchin-like TiO2 hollow spheres  

British Library Electronic Table of Contents (United Kingdom)

TiO2 hollow microspheres with sea urchin-like hierarchical architectures were synthesized by a simple hydrothermal method. The as-synthesized hollow microspheres with hierarchical architectures consisting of many rhombic building units exhibit high specific surface area. Electrorheological (ER) properties of hierarchical hollow TiO2-based suspension were investigated under steady and oscillatory shear. The hollow TiO2-based suspensions show much higher yield stress and elasticity than pure TiO2 suspension at the same electric field strength. This phenomenon was elucidated well in view of their dielectric spectra analysis. The sea urchin-like architectures result in stronger interfacial polarization of hollow TiO2 suspension upon an electric field, showing higher ER activity. Also, hollow i...

2011-01-01

60

Technology  

Indian Academy of Sciences (India)

integration with available technology and initiatives ...

61

High capacity heavy media processing  

Energy Technology Data Exchange (ETDEWEB)

Pittston Coal Company recognized the potential economic benefit of improving process efficiency with increased capacity at it`s U.K. No. 1 Coal Preparation Plant. Accordingly, extensive research, both domestically and internationally, was conducted to select the appropriate technologies to achieve the desired circuit in the most cost effective manner while, at the same time, sacrificing neither structural integrity nor process performance. Large diameter heavy media cyclone technology was combined with highly efficient banana type screens and improved high intensity magnetic separators to create a coordinated process circuit that provided high efficiency at very high capacities in an economically attractive package.

1996-12-31

62

Flow-system analysis of exfoliated pulmonary cells: results of initial characterization studies in hamsters  

Science.gov (United States)

This paper summarizes results of preliminary experiments to develop cytological and biochemical indicators for estimating damage to respiratory cells in test animals exposed by inhalation to toxic agents associated with nonnuclear energy production, the specific goal being the application of advanced multiparameter flow-systems technologies to the detection of early atypical cellular changes in lung epithelium. Normal Syrian hamster lung cell samples composed of histiocytes, leukocytes, macrophages, ciliated columnar cells, and epithelial cells were stained with fluorescent dyes specific for different biochemical parameters and were analyzed in liquid suspension as they flowed through a chamber intersecting a laser beam of exciting light. Multiple sensors measured the total or two-color fluorescence and light scatter on a cell-by-cell basis. Cellular parameters proportional to optical measurements (i.e., cell size, DNA content, total protein, ...

1976-01-01

63

Combined distiller waste utilisation and combustion gases desulphurisation method. The case study of soda-ash industry  

Energy Technology Data Exchange (ETDEWEB)

In this paper, a concept of technology that can be helpful for lowering the negative influence of the synthetic (based on the Solvay process) soda ash plant on the natural environment is presented. We describe the desulphurisation of combustion gases from the factory's power plant, which is based on their absorption in the overflow of distiller waste. The excess of lime milk, which is added in the process of ammonia regeneration from filter liquor, results in a strong alkalinity of distiller waste. The high pH of distiller waste favours absorption of acidic combustion gases. The laboratory-scale tests showed about 80% efficiency of the desulphurisation process. The suspension samples we obtained consist mainly of CaCO{sub 3}. We suggest using the obtained solid phase as an adsorbent-insert in Fluidised Bed Combustion technology (FBC). Based on raw material prices, production costs, and average sell prices of the ...

2007-09-15

64

Process in Plasma Research at IPJ and IPPLM, POLAND  

International Nuclear Information System (INIS)

The most important results of theoretical and experimental studies of plasmas, which have been achieved at the IPJ in Swierk and IPPLM in Warsaw recently, are presented. Studies of physical phenomena in PF discharges, development of diagnostic techniques and research on new plasma technologies, as performed at IPJ, have been summarized. Studies of dense magnetized plasmas, investigation of physics and applications of laser-produced plasmas; and research on the development of advanced diagnostic techniques for the EUROATOM fusion program, as performed at IPPLM, are also described.

2006-01-01

65

Kinetic energy accumulators. Application to electric cars  

Energy Technology Data Exchange (ETDEWEB)

The development of electric cars always met with the difficulty in storing energy and in recovering it in the form of electric power. Research work done for the last two decades in the field of materials and of new technologies oriented mainly towards aeronautical and space applications have led to designing, realizing and experimenting with flywheels rotating at high speed in magnetic bearings. The results obtained represent openings that, now, fall in with different industrial fields and in particular with application to electric cars.

1982-12-01

66

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

67

Radio Frequency Plasma Applications for Space Propulsion  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance ...

1999-09-13

68

Rotating magnetic tensor gradiometry and a superconducting implementation  

International Nuclear Information System (INIS)

This work describes the theoretical basis for a new concept rotating magnetic tensor gradiometer. The rotating gradiometer consists of an approximately axial or transverse gradiometer which is made to rotate about a perpendicular axis so that the direction of sensitivity is continually changing. It is demonstrated for the first time that the rotation separates gradient components of progressively higher-order in the frequency domain and enables absolute-value measurements of all components of the first-order magnetic gradient tensor, even if the magnetic sensors comprising the gradiometer are intrinsically incapable of absolute-value detection. In addition, the rotating gradiometer concept has a number of other advantages: the gradiometer imbalance is no longer directly determined by the engineering precision, the DC and low-frequency performance of the instrument is not limited by the performance of the detectors in these ...

2009-07-01

69

Recent activites on electromagnetic processing of materials in Japan  

Energy Technology Data Exchange (ETDEWEB)

Application of electromagnetic forces to materials processing, so-called {open_quotes}electromagnetic processing of materials (EPM){close_quotes} has been recognized as cutting edge technology, especially in the fields of steelmaking and advanced materials processing in Japan. The history of EPM in Japan is mentioned and the background to promote EPM is described. The current status of research and development of EPM is shown briefly introducing several examples. Regarding the application of high-frequency magnetic field, two topics are dealt with. The first is the improvement of the surface quality of cast steel where an alternating magnetic field is imposed on the molten steel from the outside of the mold, and the second is the induction cold crucible where a considerably large amount of molten intermetallic compound is levitated. Examples of the application of DC magnetic field are the control of ...

1995-01-01

70

Analysis of the requirements for economic magnetic fusion  

Energy Technology Data Exchange (ETDEWEB)

A generic reactor model is used to examine the economic viability of electricity generation by magnetic fusion. The simple model uses components which are representative of those used in previous reactor studies of deuterium-tritium burning tokamaks, stellarators, bumpy tori, reverse field pinches and tandem mirrors. Conservative costing assumptions are made. The generic reactor is not a tokamak but rather it is intended to emphasize what is common to all magnetic fusion reactors. The reactor uses a superconducting toroidal coil set to produce the dominant magnetic field. To this extent it is a less good approximation to systems, such as the reversed field pinch in which the main field is produced by a plasma current. The main output of the study is the cost of electricity as a function of the weight and size of the fusion core - blanket, shield, structure and coils. The model shows that a 1200 MW/sub e/ power plant with a ...

1986-01-01

71

Rheology of zirconia suspensions in a nonpolar organic medium  

Energy Technology Data Exchange (ETDEWEB)

Three dispersants (stearic acid, oleic acid, and poly-(12-hydroxystearic acid)) are compared for their ability to produce low-viscosity suspensions of zirconia in kerosene. Rheological measurements and sediment packing density measurements show that poly(12-hydroxystearic acid) is a better dispersant than stearic acid or oleic acid; this is explained in terms of the longer tail of the poly-(12-hydroxystearic acid) surfactant molecule. The amount of dispersant can be optimized to reduce viscosity and yield point of the suspension, and to eliminate thixotropic hysteresis. The use of a dispersion medium of lower viscosity than the dispersant makes it easy to detect when complete monolayer coverage has been achieved. The loss of pseudoplasticity, brought about by a higher degree of deflocculation, can be recovered by increasing the volume fraction of solids of a suspension and this is beneficial in the plastic forming of ...

1995-12-01

72

CERN Academic Training Programme 2008/2009  

CERN Multimedia

LECTURE SERIES 8, 9, 10 11 & 12 June 2009 11:00-12:00 - Main Auditorium, Bldg. 500 Scenarios and Technological Challenges for a LHC Luminosity Upgrade: Introduction to the LHC Upgrade Program and Summary of Physics Motivations After a general introduction to the motivations for a LHC upgrade, the lectures will discuss the beam dynamics and technological challenges of the increase of the LHC luminosity, and the possible scenarios. Items such as a stronger final focus with larger aperture magnets, crab cavities, electron cloud issues, beam-beam interaction, machine protection and collimation will be discussed.Monday 8 June 2009 Introduction to the LHC upgrade program - L. Evans Summary of Physics Motivations - M. Mangano Tuesday 9 June 2009 The Dectector Upgrade and the Requirements on the Upgrade Scenarios - M. Nessi Wednesday 10 June 2009 Scenarios for the LHC Luminosity Upgrade - F. Zimmermann Thursday 11 June 2009 ...

2009-01-01

74

Pencil-like mm-size electron beams produced with linear inductive voltage adders  

International Nuclear Information System (INIS)

We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories. The anticipated beam parameters are the following: energy 12 MeV, current 35 endash 40 kA, rms radius 0.5 mm, and pulse duration 40 ns full width at half-maximum. The accelerator is SABRE, a pulsed linear inductive voltage adder modified to higher impedance, and the electron source is a magnetically immersed foilless electron diode. 20 endash 30 T solenoidal magnets are required to insulate the diode and contain the beam to its extremely small-sized (1 mm) envelope. These experiments are designed to push the technology to produce the highest possible electron current in a submillimeter radius beam. Design, numerical simulations, and experimental results are presented. copyright 1997 American Institute of Physics.

75

Giant magnetoresistance sensing technologies for detecting small defects in metallic structures  

Science.gov (United States)

Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.

2008-01-01

76

Giant magnetoimpedance effect and voltage response in meander shape Co-based ribbon  

British Library Electronic Table of Contents (United Kingdom)

Field-annealed Co-based amorphous ribbon (Metglas? 2705M) with a meander structure is fabricated by MEMS technology and the giant magnetoimpedance (GMI) effects are studied at different magnetic fields and frequencies. The maximum longitudinal GMI ratio of the ribbon is 193.7% and the magnetic field sensitivity is 17.4%/Oe. The maximum GMI ratio of the meander ribbon is much larger than the single strip ribbon mainly due to the larger change ratio of inductance L. The sensitivity of an output U reach up to 10 V/A and U thermal fluctuation is less than 15 mV in the temperature range of ?20 to 40?C. This meander shape ribbon can be considered as a good candidate for the GMI-based sensor fabrication.

2010-01-01

77

Direct energy recovery with ac electric power output  

Energy Technology Data Exchange (ETDEWEB)

A concept of direct energy recovery system applying an alternating or rotating magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. Nearly same amounts of residual positive and negative hydrogen-isotope ion beams with beam energy of {approx}1 MeV are produced in an NNB using a gas neutralizing cell. Consequently, a recovered energy is obtained directly in the form of ac electric power, if these positive- and negative-ion beams are alternated or rotated and introduced to two or more recovery electrodes in turn by an alternating or rotating magnetic field. This concept will greatly reduce a technological difficulty in regeneration of a recovered electric energy with such a very high voltage. (author).

1994-12-31

78

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

79

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

80

[Effects of 50 to 60 Hz and of 20 to 50 kHz magnetic fields on the operation of implanted cardiac pacemakers].  

Science.gov (United States)

The effect of 50 Hz and 60 Hz (frequencies of current distribution) and 20 kHz to 50 kHz (frequencies of induction cooktop) magnetic interference on implanted pacemakers have been assessed with the present generation of device technology. Sixty patients implanted in 1998 and 1999 with dual chamber pacemakers from 9 different manufacturers were monitored with telemetry while passing through, and standing between a system of two coils. They generated a 50 Hz or a 60 Hz magnetic field at 50 microT. Then, patients used a cooktop at different power. The recordings were made with the standard setting of "medically correct" sensing parameters chosen for the patients. Then pacemakers were reprogrammed to the unipolar mode, with the highest atrial (A) and ventricular (V) sensitivity that did not induce muscular inhibition while moving. Between each exposure (50 Hz, 60 Hz or 20 kHz to 50 kHz), the pacemaker programmation was ...

2003-04-01

81

Structure properties and magnetic susceptibility of diluted magnetic semiconductor Y_2_-_xHo_xO_3  

International Nuclear Information System (INIS)

The polycrystalline samples of Y_2_-_xHo_xO_3 (0.10#<=#x#<=#1.80) were synthesized by ceramic technology. The X-ray powder diffraction data were collected and the crystal structures were refined by the Rietveld method for the samples Y_2_-_xHo_xO_3 (x=0.00, 0.20, 0.40, 1.20, 1.80, 2.00). Holmium ions Ho"3"+ were randomly distributed over two cationic sites 8b and 24d in the space group Ia3 in all refined structures. Cation-anion-cation bonds important for superexchange interaction were determined. Magnetic susceptibility measurements were done by the Faraday method in the temperature range 290 to 620 K and a behaviour in accordance with the Curie-Weiss law was obtained. The molar Curie's constants linearly depend on concentration. The effective magnetic moments of Ho"3"+ ions were smaller than the free ion value. The Curie-Weiss paramagnetic temperatures indicated antiferromagnetic interaction. The gram ion ...

1995-01-01

82

Separation Science and Technology. Semiannual progress report, April 1993--September 1993  

Energy Technology Data Exchange (ETDEWEB)

This document reports on the work done by the Separations Science and Technology Programs of the Chemical Technology Division, Argonne National Laboratory, in the period April-September 1993. This effort is mainly concerned with developing the TRUEX process for removing and concentrating actinides from acidic waste streams contaminated with transuranic (TRU) elements. The objectives of TRUEX processing are to recover valuable TRU elements and to lower disposal costs for the nonTRU waste product of the process. Other projects are underway with the objective of developing (1) evaporation technology for concentrating radioactive waste and product streams such as those generated by the TRUEX process, (2) treatment schemes for liquid wastes stored or being generated at Argonne, (3) a process based on sorbing modified TRUEX solvent on magnetic beads to be used for separation of contaminants from radioactive ...

1996-01-01

83

R and D for a single-layer Nb{sub 3}Sn common coil dipole using the react-and-wind fabrication technique  

Energy Technology Data Exchange (ETDEWEB)

A dipole magnet based on the common coil design, using prereacted Nb{sub 3}Sn superconductor, is under development at Fermilab, for a future Very Large Hadron Collider. This magnet has some innovative design and technological features such as single layer coils, a 22 mm wide 60-strand Rutherford type cable and stainless steel collars reinforced by horizontal bridges inserted between coil blocks. Both left and right coils are wound simultaneously into the collar structure and then impregnated with epoxy. In order to optimize the design and fabrication techniques an R&D program is underway. The production of cables with the required characteristics was shown possible. Collar laminations were produced, assembled and tested in order to check the effectiveness of the bridges and the validity of the mechanical design. A mechanical model consisting of a 165 mm long section of the magnet straight ...

2002-01-14

84

AquaMagna Water Conditioner and Descaler  

Wastenet

...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...

85

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

86

Reduction in the level of intracellular myo-inositol in cultured soybean (Glycine max) cells inhibits cell division.  

UK PubMed Central (United Kingdom)

Although myo-inositol is included in media for the successful growth of plant tissues, the actual requirement of most tissues, including soybean (Glycine max) callus in suspension culture, for myo-inositol...Full Text Available

1990-02-01

87

Phytochelatin Synthesis and Glutathione Levels in Response to Heavy Metals in Tomato Cells 1  

UK PubMed Central (United Kingdom)

Cell suspension cultures of tomato, Lycopersicon esculentum Mill. cv VFNT-Cherry, produce phytochelatins (poly[γ-glutamylcysteinyl]glycines) when exposed to cadmium. The synthesis...Full Text Available

1987-12-01

88

New strain of mouse hepatitis virus as the cause of lethal enteritis in infant mice.  

UK PubMed Central (United Kingdom)

A new strain of mouse hepatitis virus (MHV) was isolated from pooled gut suspensions from an epizootic of lethal enteritis in newborn mice. Negative-contrast electron microscopy showed an abundance...Full Text Available

1979-05-01

89

Hexadecane mineralization in oxygen-controlled sediment-seawater cultivations with autochthonous microorganisms.  

UK PubMed Central (United Kingdom)

Laboratory studies investigated the influence of dissolved oxygen tension (DOT) on microbial degradation of hexadecane in cultures with sediment-seawater suspensions. With a fermentor system, it was...Full Text Available

1992-09-01

90

Factors affecting the aggregation of Actinomyces naeslundii during growth and in washed cell suspensions.  

UK PubMed Central (United Kingdom)

Various factors affecting the aggregation of Actinomyces naeslundii strain 12104 were studied. When the pH of glucose-supplemented growth medium fell below 5.5, the cells aggregated and formed microbial...Full Text Available

1978-09-01

91

Effects of microwaves on the colony-forming capacity of haemopoietic stem cells in mice  

Energy Technology Data Exchange (ETDEWEB)

A suspension of bone marrow cells from femurs of female (CBA . C57B1)F1 mice was exposed to 2450 MHz CW microwaves in a specially designed waveguide exposure system. The temperature of the suspension rose, during exposure to microwaves, from 20/sup 0/C to 45/sup 0/C, and at an interval within 20/sup 0/C to 45/sup 0/C the number of haemopoietic stem cells (CFUs) was determined by the spleen exocolony method. The time of exposure of bone marrow cells to each temperature studied was 20 s. Control suspensions of bone marrow cells were exposed to a water bath temperature. There were no significant effects of the CFUs with the water bath temperature, while after exposure to microwaves the number of spleen colonies was elevated with a nadir at the temperature of 37/sup 0/C. With a microwave-induced increase of the temperature above 41/sup 0/C the number of CFUs in the bone marrow suspension decreased. The ...

1987-01-01

92

Cell-density-dependent Changes in the Metabolism of Chloronema Cell Cultures  

UK PubMed Central (United Kingdom)

In the growing chloronema cell suspension cultures of the moss Funaria hygrometrica Hedw., activities of several enzymes have been found to be cell-density-dependent. Cyclic nucleotide...Full Text Available

1979-07-01

93

Blockage by acetylene of nitrous oxide reduction in Pseudomonas perfectomarinus.  

UK PubMed Central (United Kingdom)

Suspensions of denitrifying cells of Pseudomonas perfectomarinus reduced nitrate and nitrate as expected to dinitrogen; but, in the presence of acetylene, nitrous oxide accumulated when nitrate or nitrate...Full Text Available

1976-04-01

94

Biosynthetic Pathway of Insect Juvenile Hormone III in Cell Suspension Cultures of the Sedge Cyperus iria1  

UK PubMed Central (United Kingdom)

In most insect species, juvenile hormones regulate critical physiological processes such as metamorphosis and reproduction. In insects, these sesquiterpenoids are synthesized by retrocerebral endocrine...Full Text Available

2001-10-01

95

A Nitrate Reductase-less Variant Isolated from Suspension Cultures of Datura innoxia (Mill.) 1  

UK PubMed Central (United Kingdom)

A comparative study has been carried out of the growth of two lines of Datura innoxia (Mill.) cells, designated DI-6 and NR1, their resistance to chlorate, and their ability to assimilate...Full Text Available

1980-10-01

96

Status and Challenges of the LHC Construction  

CERN Document Server

The LHC is designed to provide proton beams of 7 TeV and nominal luminosity of 10**34 cm**-2s**-1. This objective is achieved at an affordable cost by pushing all major collider components to the limits of technology, by upgrading the existing CERN accelerators and infrastructure, and by involving the technical expertise, resources and dedication of accelerator laboratories world-wide. Following a decade of intensive R&D and technical validation of major collider systems, the LHC construction is now fully underway. Major industrial contracts have been awarded and are in execution for the procurement of the magnet, cryogenics and other systems. In this report, the status of the design and construction of the major LHC systems is presented.

2001-01-01

97

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

99

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

100

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

101

Phase diagram and effective shape of semi-flexible colloidal rods and biopolymers  

CERN Document Server

We study suspensions of semi-flexible colloidal rods and biopolymers using an Onsager-type second-virial functional for a segmented-chain model. For suspensions of thin and thick fd virus particles we calculate phase diagrams in quantitative agreement with experimental observations, and we find their effective state-point dependent shape to be much shorter and thicker than the actual shape. We also calculate the stretching of worm-like micelles in a host fd virus solution, again finding agreement with experiments. For both systems, our results show that the fd virus stiffness can play a key role in system behavior.

2011-01-01

102

Influence of scattering on superluminescence in composites dye solution ? nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

Spectral and energy luminescence characteristics of R6G dye solutions in ethanol with addition of Ag nanoparticle suspensions in different aggregate states are experimentally investigated. It is demonstrated that incorporation of non-aggregated and aggregated nanoparticles causes the superluminescence thresholds in R6G solutions to decrease. It is established that the optical properties of the laser beam propagation channel are transformed when low-power (20?mW) cw laser radiation passes through the suspension of nanoparticles. This is manifested through the occurrence of a region with enhanced nanoparticle density in the laser beam center, on which diffraction of laser radiation is observed.

2011-01-01

103

Influence of scattering on superluminescence in composites dye solution - nanoparticles  

Science.gov (United States)

Spectral and energy luminescence characteristics of R6G dye solutions in ethanol with addition of Ag nanoparticle suspensions in different aggregate states are experimentally investigated. It is demonstrated that incorporation of non-aggregated and aggregated nanoparticles causes the superluminescence thresholds in R6G solutions to decrease. It is established that the optical properties of the laser beam propagation channel are transformed when low-power (20 mW) cw laser radiation passes through the suspension of nanoparticles. This is manifested through the occurrence of a region with enhanced nanoparticle density in the laser beam center, on which diffraction of laser radiation is observed.

2011-09-01

104

A wrench for screwing and unscrewing lock connections  

Energy Technology Data Exchange (ETDEWEB)

A wrench is proposed for screwing and unscrewing lock connections, which includes a spring loaded base, a faceplate with low moment and high moment mechanisms and subassemblies for moving them. In order to increase the operational reliability, the wrench is equipped with uprights evenly disposed along the perimeter of the base with hinged suspensions for linking the base, the hinged suspension is made in the form of interconnected links for the upper and lower traverses with the hinges. One of the hinges is positioned between the upper traverse and the upright, while the other is located between the lower traverse and the base.

1983-01-01

105

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

106

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of ...

2001-10-01

107

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

108

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

109

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

110

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

111

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

113

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

114

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

116

Catalytic hydrothermal gasification of biomass for the production of synthetic natural gas[Dissertation 17100  

Energy Technology Data Exchange (ETDEWEB)

Energy from biomass is a CO{sub 2} neutral, sustainable form of energy. Anaerobic digestion is an established technology for converting biomass to biogas, which contains around 60% methane, besides CO{sub 2} and various contaminants. Most types of biomass contain material that cannot be digested; in woody biomass, this portion is particularly high. Therefore, conventional anaerobic digestion is not suited for the production of biogas from woody biomass. While wood is already being converted to energy by conventional thermal methods (gasification with subsequent methanation), dung, manure, and sewage sludge represent types of biomass whose energy potential remains largely untapped (present energetic use of manure in Switzerland: 0.4%). Conventional gas phase processes suffer from a low efficiency due to the high water content of the feed (enthalpy of vaporization). An alternative technology is the hydrothermal gasification: the water contained ...

2007-07-01

117

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...

2009-03-01

118

Test results of TQS03: a LARP shell-based Nb3Sn quadrupole using 108/127 conductor  

Energy Technology Data Exchange (ETDEWEB)

Future insertion quadrupoles with large apertures and high gradients will be required for the Phase II luminosity upgrade (10{sup 35} cm{sup -2}s{sup -1}) of the Large Hadron Collider (LHC). Although improved designs, based on NbTi, are being considered as an intermediate step for the Phase I upgrade, the Nb{sub 3}Sn conductor is presently the best option that meets the ultimate performance goals for both operating field and temperature margin. As part of the development of Nb{sub 3}Sn magnet technology, the LHC Accelerator Research Program (LARP) developed and tested several 1-meter long, 90-mm aperture Nb{sub 3}Sn quadrupoles. The first two series of magnet used OST MJR 54/61 (TQ01 series) and OST RRP 54/61 (TQ02 series) strands. The third series (TQ03) used OST RRP 108/127 conductor. The larger number of sub-elements and the consequent reduction of the effective filament size, together with an increased fraction of ...

2009-09-13

119

New Forming Limits For Light Alloys By Means Of Electromagnetic Forming And Numerical Simulation Of The Process  

Science.gov (United States)

It is well known that one of the main advantages of the high speed forming (HSF) processes is the improvement in the forming limits of the used materials.Using the Electromagnetic Forming (EMF) technology two materials have been tested with different mechanical and physical properties: the AA5754 aluminium and the AZ31B magnesium alloys.The EMF process principle can be described as follows: A significant amount of electrical energy is stored in a bank of capacitors which are suddenly discharged releasing all the stored energy. This electric discharge runs through a coil which generates an intense transient magnetic field. At the same time transient Eddy currents are induced in the electrically conductive part placed some millimetres far from the coil. Another intense magnetic field is generated due to those Eddy currents but on the opposite direction as the one generated by the coil. A big magnetic ...

2007-04-07

120

New Forming Limits For Light Alloys By Means Of Electromagnetic Forming And Numerical Simulation Of The Process  

International Nuclear Information System (INIS)

It is well known that one of the main advantages of the high speed forming (HSF) processes is the improvement in the forming limits of the used materials.Using the Electromagnetic Forming (EMF) technology two materials have been tested with different mechanical and physical properties: the AA5754 aluminium and the AZ31B magnesium alloys.The EMF process principle can be described as follows: A significant amount of electrical energy is stored in a bank of capacitors which are suddenly discharged releasing all the stored energy. This electric discharge runs through a coil which generates an intense transient magnetic field. At the same time transient Eddy currents are induced in the electrically conductive part placed some millimetres far from the coil. Another intense magnetic field is generated due to those Eddy currents but on the opposite direction as the one generated by the coil. A big magnetic ...

2007-04-07

121

Suspension and solution plasma spraying of finely structured layers: potential application to SOFCs  

International Nuclear Information System (INIS)

Suspension direct current plasma spraying allows achieving finely structured coatings whose thickness is between few tens and few hundreds of micrometres. Drops (200-300 ?m in diameter) or liquid jets are mechanically injected in the plasma jet. With radial injection they are rapidly (a few ?s) fragmented into droplets (a few ?m in diameter). The latter are vaporized (in a few ?s) and the solid particles contained in suspension droplets are accelerated and melted by the plasma jet. As in conventional plasma spraying (CPS), much smaller splats (with diameters between 0.2 and 3 ?m and thicknesses between 30 and 200 nm) are arranged in layers up to form the coating. The low inertia of particles requires spray distances between 40 and 60 mm which induces plasma heat fluxes up to 22 MW m-2 participating in coating densification. Even more than in CPS, the plasma jet fluctuations, particularly for plasmas containing di-atomic gases, perturb drops ...

2007-04-21

122

Combustion characteristics of fuel droplets with addition of nano and micron-sized aluminum particles  

Energy Technology Data Exchange (ETDEWEB)

The burning characteristics of fuel droplets containing nano and micron-sized aluminum particles were investigated. Particle size, surfactant concentration, and the type of base fluid were varied. In general, nanosuspensions can last much longer than micron suspensions, and ethanol-based fuels were found to achieve much better suspension than n-decane-based fuels. Five distinctive stages (preheating and ignition, classical combustion, microexplosion, surfactant flame, and aluminum droplet flame) were identified for an n-decane/nano-Al droplet, while only the first three stages occurred for an n-decane/micron-Al droplet. For the same solid loading rate and surfactant concentration, the disruption and microexplosion behavior of the micron suspension occurred later with much stronger intensity. The intense droplet fragmentation was accompanied by shell rupture, which caused a massive explosion of particles, and most of them ...

2011-02-15

123

Test Bed for Superconducting Materials  

Energy Technology Data Exchange (ETDEWEB)

Superconducting rf cavities are increasingly used in accelerators. Gradient is a parameter of particular importance for the ILC. Much progress in gradient has been made over the past decade, overcoming problems of multipacting, field emission, and breakdown triggered by surface impurities. However, the quenching limit of the surface magnetic field for niobium remains a hard limitation on cavity fields sustainable with this technology. Further exploration of materials and preparation may offer a path to surpassing the current limit. For this purpose, we have designed a resonant test cavity. One wall of the cavity is formed by a flat sample of superconducting material; the rest of the cavity is copper or niobium. The H field on the sample wall is 75% higher than on any other surface. Multipacting is avoided by use of a mode with no surface electric field. The cavity will be resonated through a coupling iris with high-power rf at superconducting ...

2006-01-30

124

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously produced to meet ...

1999-12-01

125

Development of large-capacity refrigeration at 1.8 K for the Large Hadron Collider at CERN  

CERN Document Server

CERN, the European Laboratory for Particle Physics, is working towards the construction of the Large Hadron Collider (LHC), a high-energy, high-luminosity particle accelerator and collider [1] of 26.7 km circumference, due to start producing frontier physics, by bringing into collision intense proton and ion beams with centre-of-mass energies in the TeV-per-constituent range, at the beginning of the next century. The key technology for achieving this ambitious scientific goal at economically acceptable cost is the use of high-field superconducting magnets using Nb-Ti conductor operating in superfluid helium [2]. To maintain the some 25 km of bending and focusing magnets at their operating temperature of 1.9 K, the LHC cryogenic system will have to produce an unprecedented total refrigeration capacity of about 20 kW at 1.8 K, in eight cryogenic plants distributed around the machine circumference [3]. This has requested the ...

1996-01-01

126

Role of E-cadherin in the induction of apoptosis of HPV16-positive CaSki cervical cancer cells during multicellular tumor spheroid formation  

British Library Electronic Table of Contents (United Kingdom)

Multicellular tumor spheroids (MCTS) are three dimensional cell culture systems induced by suspension culture. MCTS are widely used in cancer research because of their similarity to solid tumors. CaSki cells are derived from a metastatic cervical cancer containing human papillomavirus 16 (HPV16). Cell death of CaSki cells in MCTS has been previously reported, and our model is used to better characterize the mechanisms of cell death of HPV16-positive keratinocytes. In this study, we found that apoptosis of CaSki cells was induced by suspension culture along with the formation of MCTS after 24?h of incubation. In suspended CaSki cells, monoclonal antibodies blocking E-cadherin function inhibited MCTS formation and suppressed suspension-induced apoptosis in a dose-dependent manner. Western bl...

2008-01-01

127

Effects of the structural nature of the anionic additives on the rheological behavior of bentonite suspensions; Effets de la nature structurelle des additifs anioniques sur le comportement rheologique de suspensions de bentonite  

Energy Technology Data Exchange (ETDEWEB)

Different experimental measurements (Theology, granulometry, XRD) were carried out in order to study the main properties of bentonite suspensions in presence of anionic additives at different concentrations. These additives are: Sodium Dodecyl Sulfate (SDS) as surfactant, a flexible polymer (Sodium Carboxy Methyl Cellulose, CMC) and a semi-rigid polymer (Xanthan gum). It has been shown that the structural nature of anionic additive influences directly the mixtures viscoelastic and flow behavior. The steric effect of the surfactant modifies the Face-Edge interactions and yields changes of the mixtures rheological behavior at low deformation rates. Polymers act by coating each clay particle and prevent their agglomeration. Therefore, bentonite has no direct effect on the rheological behavior of the mixtures: the additives are responsible for the mechanisms of de-structuration and structure reorganization as well as the mixtures viscous and viscoelastic behavior. ...

2005-07-01

128

Apparent slip at the surface of a small rotating sphere in a dilute quiescent suspension  

Energy Technology Data Exchange (ETDEWEB)

We consider the case of a test sphere (ball) of radius a{sub 1} rotating at constant angular velocity {omega} in an otherwise quiescent unbounded suspension of uniformly sized spheres of radii a{sub 2} dispersed in a Newtonian fluid of viscosity {mu}. To the first order in the volume fraction c of suspended spheres it is shown that when the ball is small compared with the suspended spheres the suspension does not behave as regards the hydrodynamic torque L exerted on the ball like a homogeneous Newtonian fluid characterized by the usual Einstein viscosity coefficient {mu}{sub s}={mu}(1+5/2c). Explicitly, the torque on the rotating sphere does not obey Kirchoff{close_quote}s law, L=8{pi}{mu}{sub s}a{sub 1}{sup 3}{omega} for no slip. Rather, a modified form of Kirchoff{close_quote}s law is obtained in which the Einstein coefficient of 5/2 is multiplied by a coefficient which is less than unity in magnitude and is functionally dependent only upon ...

1998-03-01

129

The controlled creation of a maximally entangled state between a SQUID ring and a single electromagnetic field mode  

International Nuclear Information System (INIS)

We consider a SQUID ring inductively coupled to an electromagnetic field mode, both treated quantum mechanically. We demonstrate a method for creating a maximally entangled state between the ring and the field mode. Our method utilises a non-adiabatic external magnetic flux pulse to move into and out of a transition region. Hence, our approach is fundamentally different to techniques based on Landau-Zener tunnelling that can also be used to achieve similar results. Our analysis is extended to include the effects of coupling the system to a dissipative environment. With this model we show that although such an environment makes a noticeable difference to the time evolution of the system, it need not destroy the entanglement of this coupled system over time scales required for quantum technologies.

2010-07-01

130

Stability of A-15 compounds in multifilamentary superconducting wires  

International Nuclear Information System (INIS)

With the preeminence of A-15 superconducting multifilamentary wires in magnet technology, it has become important to understand the thermodynamic factors influencing the formation of these compounds under solid-state reaction conditions. The six systems Nb--Sn, Nb--Ga, Nb--Ge, Nb--Al, V--Si, and V--Ga were prepared as single filament bronze wires and heat treated in an attempt to precipitate the appropriate A-15 compound. The compounds observed to form were categorized using a formation temperature ratio (stability index) based on the melting temperatures of the constituents which make up the single filament composites. This study has led to several predictions regarding the formation of A-15 compounds using a solid-state bronze diffusion technique. The results of experimentation based on these predictions are presented.

131

Recognizing limitations in eddy current testing  

International Nuclear Information System (INIS)

This paper addresses known limitations and constraints in eddy current nondestructive testing. Incomplete appreciation for eddy current limitations is believed to have contributed to both under-utilization and misapplication of the technique. Neither situation need arise if known limitations are recognized. Some, such as the skin depth effect, are inherent to electromagnetic test methods and define the role of eddy current testing. Others can be overcome with available technology such as surface probes to find circumferential cracks in tubes and magnetic saturation of ferromagnetic alloys to eliminate permeability effects. The variables responsible for limitations in eddy current testing are discussed and where alternative approaches exist, these are presented. Areas with potential for further research and development are also identified.

1993-11-01

132

Properties of molecular solids and fluids at high pressure and temperatures  

Energy Technology Data Exchange (ETDEWEB)

This renewal request for DOE grant DE-FG02-86ER45238, is dedicated to providing a complete thermodynamic profile of solids fluids, and fluid mixtures, over a wide range of temperatures and pressures. We are partially motivated by technological interest in detonation, combustion, superhard high pressure materials, and high temperature superconductors, which are important components of interest of various DOE laboratories. Our work on fluids and solids, composed of simple molecules, involves the determination of structures, phase transitions, pressure-volume relations, phonon, vibron, and libron modes of excitation, sound velocities, specific heats, thermal expansion, virial coefficients, sublimation energies, and orientational translational, and magnetic correlations. We hope that the study of these systems under extreme thermodynamic conditions will lead to exotic new materials of value, as well as enhanced fundamental understanding.

1992-03-01

133

Overview of industrial applications of induction; L'induction au service de l'industrie: panorama des applications industrielles  

Energy Technology Data Exchange (ETDEWEB)

Because power requirements in induction heating applications are largely dependent on the physical properties of the product to be heated, inducting, heating is mainly used in steelwork applications, for the manufacture of finished or semi-finished parts. Applications here cover five main types of steelworks operation: smelting, heating prior to forming, heat treatment, surface treatment, and assembly process. At the same time, technological progress has opened up innovative applications in sectors such as chemical and agro-food industries. Other emerging applications for induction include direct forming of liquid metal, wholly or partially replacing mechanical transformations on solid metal. Techniques include electromagnetic forming, continuous cold-crucible casting, electromagnetic mixing, flow control by continuous magnetic field, and production of intense sliding fields (pumps, flow regulation). (author)

2004-05-01

134

Nano photonic sensors for microdamage detection : an exploratory simulation.  

Energy Technology Data Exchange (ETDEWEB)

Nano photonic materials are synthetically manufactured crystals at the nano scale with the target of creating a microstructure with a special electro-magnetic periodicity. Such nano photonic materials have the ability to control light propagation and thus are capable of creating photonic bandgaps in the frequency domain. We propose using nano photonic crystals as sensors to detect microdamage in composite materials. We demonstrate using a simulation model that a nano photonic sensor attached to a composite bar experiences a significant change in its bandgap profile when damage is induced in the composite bar. The model predicts the frequency response of the nano photonic sensor using the transfer matrix method. A damage metric to evaluate the change in the frequency response is developed. Successful developments of nano photonic sensors allow damage identification at scales not attainable using current sensing technologies.

2005-04-01

135

Los Alamos Advanced Free-Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

At Los Alamos, we are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact in size, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported using permanent-magnet quadrupoles and dipoles. They will form an electron beam with an excellent instantaneous beam quality of 10 {pi} mm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends form 3.7 {mu}m to 0.4 {mu}m. In this paper, we will describe the project and the programs to date. 10 refs., 10 figs., 1 tab.

1991-01-01

136

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

137

Design and evaluation of coils for a 50 mm diameter induction coilgun launcher  

Energy Technology Data Exchange (ETDEWEB)

Coilguns have the ability to provide magnetic pressure to projectiles which results in near constant acceleration. However, to achieve this performance and control projectile hearing, significant constraints are placed on the design of the coils. We are developing coils to produce an effective projectile base pressure of 100 MPa (1kbar) as a step toward reaching base pressures of 200 MPa. The design uses a scalable technology applicable to the entire range of breech to muzzle coils of a multi-stage launcher. This paper presents the design of capacitor-driven coils for launching nominal 50 mm, 350 gram projectiles. Design criteria, constraints, mechanical stress analysis, launcher performance, and test results are discussed.

1993-12-31

138

Biopolymer system for permeability modification in porous media  

Energy Technology Data Exchange (ETDEWEB)

New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were ...

1995-12-31

139

Application of high velocity impact welding at varied different length scales  

British Library Electronic Table of Contents (United Kingdom)

Three complementary impact welding technologies are described in this paper. They are explosive welding, magnetic pulse welding, and laser impact welding, which have been used to provide metallurgical bonds between both similar and dissimilar metal pairs. They share the physical principle that general impact-driven welding can be carried out by oblique impact but are used at different length scales from meters to sub-millimeter. The different length scales require different kinds of systems to drive the process, and the scales themselves can give different weld morphologies. Metallographic analysis on cross-sections shows a wavy interface morphology which is likely the result of an instability associated with jetting, which scours the surfaces clean during impact. The normalized period and...

2011-01-01

140

A Study on the Design of Linear Motor with Transverse Flux Configuration for Railway Traction System  

Energy Technology Data Exchange (ETDEWEB)

According to the development of power electronic element (GTO, IGBT) nd material for electrical machines (permanent magnet, super conductor), the technology for electrical machines is now a day rapidly developing. here with, a novel electrical machine, based on the new conception of transverse flux configuration leads to a considerable increase in power density and enables simultaneously high efficiency.The transverse flux machine with PM excitation will be applied to gearless direct drives for railway traction system. The designed and measured performance of transverse machine for railway traction system revealed a great potential of system improvements to reduce linear motor mass. (author). 10 refs., 14 figs., 3 tabs.

1999-06-01

141

'11-th International Conference - School on Plasma Physics and Controlled Fusion and 2-nd International Workshop on the Role of Electric Fields in Plasma Confinement in Stellarators and Tokamaks'. Book of abstracts  

International Nuclear Information System (INIS)

About 210 abstracts by Ukrainian and foreign authors submitted to the 11-th International Conference on Plasma Physics and Controlled Fusion and 2-nd Alushta International Workshop on the Role of Electric Fields in Plasma Confinement in Stellarators and Tokamaks have been considered by Conference Program Committee members. All the abstracts have been divided into 9 groups: Magnetic confinement systems (stellarators, tokamaks, alternative conceptions); plasma heating and current drive; ITER and fusion reactor aspects; basic plasma physics; space plasma; plasma dynamics and plasma-wall interaction; plasma electronics; low temperature plasma and plasma technologies; plasma diagnostics.

2006-09-11

142

The entrepreneur's guide to managing information technology  

CERN Document Server

The entrepreneur's guide to managing information technology

2008-01-01

143
144

Local access network technologies  

CERN Document Server

Local access network technologies

2004-01-01

145

Handbook on information technology in finance  

CERN Document Server

Handbook on information technology in finance

2008-01-01

146

Digital Library Technology Trends  

CERN Document Server

Digital Library Technology Trends

2002-01-01

147

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...

1981-11-11

149

Magnetic braking of the rotation of molecular cloud cores  

International Nuclear Information System (INIS)

We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).

150

LHC magnet alignment  

CERN Document Server

Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.

2007-01-01

151

The efficacy of simulated solar disinfection (SODIS) against Ascaris, Giardia, Acanthamoeba, Naegleria, Entamoeba and Cryptosporidium  

British Library Electronic Table of Contents (United Kingdom)

The antimicrobial activity of simulated solar disinfection (SODIS) in the presence and absence of riboflavin against various protozoa and helminth organisms was investigated in this study. Assays were conducted in transparent 12 well microtitre plates containing a suspension of test organisms in the presence or absence of 250mM riboflavin. Plates were exposed to simulated sunlight at an optical irradiance of 550Wm^-^2 (watts per square metre) delivered from a SUNTEST(TM) CPS+ solar simulator. Aliquots of the test suspensions were taken at set time points and the viability of the test organisms was determined by either culture, microscopy or flow cytometry where applicable. With Acanthamoeba, Naegleria, Entamoeba and Giardia exposure to SODIS at an optical irradiance of 550Wm^-^2 for up to ...

2011-01-01

152

Semiactive field-controllable magneto-rheological fluid dampers for mountain bicycles  

Science.gov (United States)

This paper presents the development and evaluation of field- controllable, semi-active magneto-rheological fluid (MRF) shock absorbers for a mountain bicycle. Recent trends in the bicycle industry show a movement towards semi-active suspension systems. Two new MRF dampers are designed and tested with the intent of being used on the front and rear suspension of a modern mountain bicycle. The MRF shock absorbers are designed to emulate the performance of the original equipment manufacturer shock absorbers in passive mode. Application of an input electric current to the MRF shock absorber causes a dramatic increase in the damping capacity. Procedures and results are presented for the design and experimental characterization of these MRF dampers.

2000-06-01

153

Properties and processing of TIMETAL LCB  

Science.gov (United States)

TIMETAL LCB was introduced more than 10 years ago targeting automotive suspension spring applications. The alloy development aim was to use a low-cost formulation by selecting less expensive raw materials than typical beta titanium alloys. Following the first successful application of TIMETAL LCB suspension springs to series production vehicles, the 2000 Volkswagen Lupo FSI, the springs have been used for Ferrari Challenge Stradale since 2003. The most recent development effort was focused on the generation of metallurgical and mechanical service data for the alloy, and the implementation of efficient low cost processing of coils. This paper will introduce various properties of TIMETAL LCB products that can be useful in the design and the consideration of spring applications. Recent progress in the processing of TIMETAL LCB will also be introduced and discussed.

2005-12-01

154

Process for producing calcium sulfate dihydrate during desulfurization of stack gases from power station boilers. Verfahren zur Herstellung von Calciumsulfat-Dihydrat im Zuge der Entschwefelung von Rauchgasen aus Kraftwerkskesselfeuerungen  

Energy Technology Data Exchange (ETDEWEB)

This is a process for producing calcium sulfate dihydrate during desulfurization of stack gases from power station boilers, where the stack gases are introduced into a washing tower and are treated with a washing water suspension containing lime in the washing tower, where oxygen in the form of air or of air enriched in oxygen is also blown into the washing tower, and where the washing water suspension drawn off from the washing tower is fed back to the washing tower at a temperature of 45 to 50/sup 0/C in the circuit and at least part of the flow goes via a thickener and where calcium sulfate dihydrate slurry is drawn off from the thickener.

1986-06-12

155

Passivity of iron in red mud's water solutions  

International Nuclear Information System (INIS)

Red mud suspensions are studied as passivating agents for iron in alkaline chloride media. Red mud particles in alkaline media are negatively charged, and can absorb considerable amounts of protons without significant changes in pH. These particles adhere easily to an iron surface forming aggregates of heterogeneous shape, smaller than 10 #mu#mx10 #mu#m. These adhered particles recrystallise on potential cycling, and hinder metal dissolution and magnetite formation. Carbon steel samples passivated in red mud suspensions become resistant to corrosion in alkaline chloride media. Corrosion potential versus time records and impedance spectroscopy measurements allow formulating some hypotheses about the inhibiting mechanism.

2004-07-30

156

Passivity of iron in red mud's water solutions  

Energy Technology Data Exchange (ETDEWEB)

Red mud suspensions are studied as passivating agents for iron in alkaline chloride media. Red mud particles in alkaline media are negatively charged, and can absorb considerable amounts of protons without significant changes in pH. These particles adhere easily to an iron surface forming aggregates of heterogeneous shape, smaller than 10 {mu}mx10 {mu}m. These adhered particles recrystallise on potential cycling, and hinder metal dissolution and magnetite formation. Carbon steel samples passivated in red mud suspensions become resistant to corrosion in alkaline chloride media. Corrosion potential versus time records and impedance spectroscopy measurements allow formulating some hypotheses about the inhibiting mechanism.

2004-07-30

157

Gradiometry coexperiments to the gravity probe B and step missions  

Energy Technology Data Exchange (ETDEWEB)

The Gravity Probe-B (GP-B) spacecraft, designed to test predictions of general relativity, will fly in the mid 1990s. It will carry four electrostatically suspended gyroscopes in a cryogenic environment and will have a drag-free control system to minimize disturbances on the gyroscopes. The Stanford Test of Equivalence Principle (STEP) spacecraft, to fly later, will carry a set of test masses under very similar conditions. The possibility of using differential measurements of the GP-B gyroscopes suspension forces and the STEP tests mass displacement readout to form single-axis gravity gradiometers is explored. It is shown that the noise in the suspension systems is sufficiently small in the relevant frequency range, and that enough information is collected to compensate for the spacecrafts' attitude motion. Finally, using Breakwell's flat-earth approximation, these experiments are compared to other geodesy experiments and ...

1990-01-01

158

Effect of Relative Humidity on Deinococcus radiodurans? Resistance to Prolonged Desiccation, Heat, Ionizing, Germicidal, and Environmentally Relevant UV Radiation  

British Library Electronic Table of Contents (United Kingdom)

To test the effect of humidity on the radiation resistance of Deinococcus radiodurans, air-dried cells were irradiated with germicidal 254?nm UV, and simulated environmental UV or ?-radiation and survival was compared to cells in suspension. It was observed that desiccated cells exhibited higher levels of resistance than cells in suspension toward UV or ?-radiation as well as after 85?C heat shock. It was also shown that low relative humidity improves survival during long-term storage of desiccated D. radiodurans cells. It can be concluded that periods or environments in which cells exist in a dehydrated state are beneficial for D. radiodurans? survival exposed to various other stresses.

2011-01-01

159

Correlated accumulation of anthocyanins and rosmarinic acid in mechanically stressed red cell suspensions of basil (Ocimum basilicum)  

British Library Electronic Table of Contents (United Kingdom)

A red basil cell line (T2b) rich in rosmarinic acid (RA) was selected for the stable production of anthocyanins (ACs) in the dark. Cell suspension cultures were subjected to mechanical stress through increased agitation (switch from 90 to 150rpm) to determine the relationship between AC and RA accumulation. Cell extracts were analyzed by HPLC and LC-MS, and the resulting data were processed with multivariate statistical analysis. MS and MS/MS spectra facilitated the putative annotation of several complex cyanidin-based ACs, which were esterified with coumaric acid and, in some cases, also with malonic acid. It was also possible to identify various RA-related molecules, some caffeic and coumaric acid derivatives and some flavanones. Mechanical stress increased the total AC and RA contents, ...

2011-01-01

160

Contrast Sensitivity and Optical Quality of the Eye after Instillation of Timolol Maleate Gel-Forming Solution and Brinzolamide Ophthalmic Suspension  

British Library Electronic Table of Contents (United Kingdom)

Purpose To investigate the influence of timolol maleate 0.5% gel-forming solution and brinzolamide 1% ophthalmic suspension on contrast sensitivity, ocular higher-order aberration (HOA), and corneal surface light scattering. Design Prospective, comparative study. Participants Forty normal volunteers were enrolled in this study. Methods We evaluated contrast sensitivity, ocular HOA, and corneal light scattering before and 2, 5, 10, and 15 minutes after instillation of antiglaucoma eyedrops. Contrast sensitivity function was assessed with the CSV-1000RN chart (Vector Vision Co., Greenville, OH). Higher-order aberration was measured for a 4-mm pupil using the Hartmann-Shack aberrometer (KR-9000PW; Topcon, Tokyo, Japan). Corneal surface light scattering was quantitatively evaluated by using th...

2010-01-01

161

Combined radiation and convection in absorbing, emitting, nongray gas-particulate tube flow  

Energy Technology Data Exchange (ETDEWEB)

The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as ...

1987-05-01

162

Combined radiation and convection in absorbing, emitting, non-Gray gas-particulate tube flow  

Energy Technology Data Exchange (ETDEWEB)

The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as well as ...

1985-01-01

163

Waste to energy technologies.  

Science.gov (United States)

No abstract prepared.

2010-04-01

164

Technology Strategy Board  

Wastenet

Technology Strategy Board Driving Innovation ...Technology Strategy 2009-2012 ... The vision of the Technology Strategy Board is for the UK to be a global leader in innovation

166

ELMO Bumpy Torus Reactor and power plant: conceptual design study  

International Nuclear Information System (INIS)

A complete power plant design of a 1200-MWe ELMO Bumpy Torus Reactor (EBTR) is presented. An emphasis is placed on those features that are unique to the EBT confinement concept, with subsystems and balance-of-plant items that are more generic to magnetic fusion being adapted from past, more extensive tokamak reactor designs. Similar to the latter tokamak studies, this conceptual EBTR design also emphasizes the use of conventional or near state-of-the-art engineering technology and materials. An emphasis is also placed on system accessibility, reliability, and maintainability, as these crucial and desirable characteristics relate to the unique high-aspect-ratio configuration of EBTs. Equal and strong emphasis is given to physics, engineering/technology, and costing/economics components of this design effort. Parametric optimizations and sensitivity studies, using cost-of-electricity as an object function, are reported. Based ...

1988-10-09

167

Conceptual design of the Fast-Liner Reactor (FLR) for fusion power  

International Nuclear Information System (INIS)

The generation of fusion power from the Fast-Liner Reactor (FLR) concept envisages the implosion of a thin (3-mm) metallic cylinder (0.2-m radius by 0.2-m length) onto a preinjected plasma. This plasma would be heated to thermonuclear temperatures by adiabatic compression, pressure confinement would be provided by the liner inertia, and thermal insulation of the wall-confined plasma would be established by an embedded azimuthal magnetic field. A 2- to 3-mu s burn would follow the approx. 10"4 m/s radial implosion and would result in a thermonuclear yield equal to 10 to 15 times the energy initially invested into the liner kinetic energy. For implosions occurring once every 10 s a gross thermal power of 430 MWt would be generated. The results of a comprehensive systems study of both physics and technology (economics) optima are presented. Despite unresolved problems associated with both the physics and technology of the FLR, ...

168

Advances in beam physics and technology: Colliders of the future  

International Nuclear Information System (INIS)

Beams may be viewed as directed and focussed flow of energy and information, carried by particles and electromagnetic radiation fields (ie, photons). Often, they interact with each other (eg, in high energy colliders) or with other forms of matter (eg, in fixed targets, sychrotron radiation, neutron scattering, laser chemistry/physics, medical therapy, etc.). The whole art and science of beams revolve around the fundamental quest for, and ultimate implementation of, mechanisms of production, storage, control and observation of beams -- always directed towards studies of the basic structures and processes of the natural world and various practical applications. Tremendous progress has been made in all aspects of beam physics and technology in the last decades -- nonlinear dynamics, superconducting magnets and rf cavities, beam instrumentation and control, novel concepts and collider praradigms, to name a few. We illustrate this progress with a ...

1994-11-14

169

Active SWD using monochromatic source wavelet; Tan`itsu shuhasu no shingen hakei wo mochiita active SWD  

Energy Technology Data Exchange (ETDEWEB)

As part of developing efforts for physical exploration technologies for oil reservoirs, this paper describes development of an active seismic while drilling (SWD). The SWD is a seismic exploration method to acquire records equivalent to VSP using seismic waves generated from a bit executing excavation, and is capable of detection and control on a real time basis during the excavation. However, the drawback is that it is subjected to a limitation in the bit. To eliminate this limitation, an artificial seismic source method was devised. In other words, this is an SWD utilizing an artificial seismic source. The contrivance is such that a shot sub containing a magnetic distortion oscillator is attached directly above a bit to generate vibration artificially, and try to utilize larger seismic energy by combining this vibration with that generated from the excavating bit. Frequency band in the seismic source is as narrow as nearly a single frequency ...

1997-05-27

170

Transitioning DARPA Technology  

Science.gov (United States)

Page 1. TRANSITIONING DARPA TECHNOLOGY ... Transitioning DARPA Technology JAMESJ.RJCHARDSON DIANE L. LARRNA ...

2001-05-01

171

Physical and optical properties of rare earth cobalt magnets  

Energy Technology Data Exchange (ETDEWEB)

Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.

1980-08-01

177

METHOD OF FORMING THIN MAGNETIC FILM  

J-STORE (Japan)

Full Text Available

2007-10-04

183

NASA TECH BRIEF  

Science.gov (United States)

Magnetic Forming Studies. The use of transient high magnetic-field devices has made possible the generation of very large accurately ...

185

Magnetic properties of single crystalline RE_2PdSi_3 intermetallic compounds  

International Nuclear Information System (INIS)

... susceptibility magnetization magnetoresistance monocrystals order-disorder

186

Finite Element Analysis of Magnetoelastic Plate Problems.  

Science.gov (United States)

... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...

1981-08-01

187

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

188

An investigation of the decoupling effects in a magnetic forming beryllium coil assembly.  

Science.gov (United States)

Decoupling force exerted by magnetic forming Be coil assembly on metallic plate during forming

1968-01-01

190

Beam direct converter with varying magnetic field  

Energy Technology Data Exchange (ETDEWEB)

The concept of a direct energy recovery system that applies a varying magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. The output beam energy and power of such an NNB will be {approximately}1 MeV and {approximately}1- MW/beam-line, respectively, and nearly the same amounts of positive- and negative-ion beams remain unneutralized in an NNB by using a gas-neutralizing cell. Therefore, the output of a beam direct convertor in an NNB is a bipolar direct current (dc) electric power with close to {plus_minus} 1 MV and several amperes if a conventional electrostatic or magnetostatic field is applied for ion beam separation. However, such high-voltage dc power is difficult to handle at the point of the regeneration of the power back to a commercial electric line because a very high voltage inverter tough enough to withstand occasional sparkdowns at recovery electrodes ...

1994-12-01

191

The Isolation and Characterization of d-Glucose 6-Phosphate Cycloaldolase (NAD-Dependent) from Acer pseudoplatanus L. Cell Cultures  

UK PubMed Central (United Kingdom)

A soluble enzyme system from suspension cultures of Acer pseudoplatanus L. converts d-glucose 6-phosphate to myoinositol. A Mg2+-dependent phosphatase, present in...Full Text Available

1971-09-01

192

Pressurized electroosmotic dewatering (PED) of fine coal suspensions  

Science.gov (United States)

Current dewatering methods for ultra-fine coal suspensions are inadequate and usually require subsequent expensive thermal drying. This unique dewatering method is based on pressurized electroosmosis, the movement of water by an electrical field through a porous medium, under modest pressure, e.g., 110 psi. More ultra-fine coal can be utilized since an effective dewatering process can be realized by combining known filtration techniques with electroosmosis. The dewatering efficiency can be significantly improved, the residual moisture of the cake can be substantially reduced and handling problems can be eliminated. Bench-scale testing is being used to optimize the parameters which influence pressurized electroosmotic dewatering (PED) of ultra-fine coal suspensions. Particle size distribution is being addressed to obtain a maximum density for a given pressure such that pore saturation is maintained allowing electroosmosis to be effective for a ...

1985-01-01

193

NAME=\\  

Wastenet

... The relation between turbulence structure and a scalar detected using a new statistical test for the change in fractal dimension of a time-series, Department of Geography, University of Durham Workshop on Coherent Structures in Rivers Keylock C.J., Nishimura K., Nemoto M., Ito Y. 2006. The wake structure from fractal fences: implications for the control of turbulent suspensions, Warwick Turbulence ...

194

International workshop on 'in vitro' culture of forest tree species. Colloque international sur la culture 'in vitro' des essences forestieres  

Energy Technology Data Exchange (ETDEWEB)

Some 43 papers were presented in 4 sections: Organ and bud culture of tree species (24 papers); Cell suspension and callus culture of tree species (11); Culture of haploid tissue of tree species and production of wood homozygotes (3); and Isolation, culture and somatic fusion of protoplasts as a means of somatic hybridization and genetic engineering (5).

1983-01-01

195

Improvement in loosening equipment  

Energy Technology Data Exchange (ETDEWEB)

The loosening equipment consists of a base machine and four-link suspension mechanism which is a cross frame with loosening gear connected to the base machine by universal hinges. In order to improve the reliability of the machine, the drive of transverse shifting in the cross frame is made of symmetrically arranged, shock-absorbing, hydraulic cylinders which are connected by additional universal hinges to the base machine and the lower pull rods. The design of the loosening machine guarantees its reliable operation on soil with significant quantity of hard inclusions.

1982-01-01

196

Evaluating and improving the operating reliability of the units of sucker rod well pumps  

Energy Technology Data Exchange (ETDEWEB)

The theory of reliability is used to develop statistical field data on malfunctions of units of sucker rod well pumps (UShSN). The indices of reliability of the UShSN are applied for establishment of the cause-effect links between the operating factors. Dependences of operating time on the depth of suspension of the pumps, mode of pumping out, degree of flooding of the oil, and twisting of the shafts are established for conditions of specific fields. The obtained relationships can be used in selecting and optimizing the work of the UShSN.

1982-01-01

197

Effect of ultrasonic energy on Mn-Zn ferrite powder behavior  

Energy Technology Data Exchange (ETDEWEB)

Effect of ultrasonic-wave irradiation on the Mn-Zn ferrite powder suspension prepared by solid-state reaction and alcoholic dehydration methods was investigated. Size, distribution, and morphology of the powders prepared at different temperatures were examined, as a function of irradiation time. It was observed that the powders were reduced in size by ultrasonic energy through distinct routes. 8 refs., 7 figs., 1 tab.

1999-07-01

198

Coal uses and upgrading processes  

Energy Technology Data Exchange (ETDEWEB)

The paper discusses the status of coal as a raw material and energy source. After referring to coal preparation and the costs it involves the author deals with coal/liquid suspensions and their fueling uses. Access is given to different aspects concerning the use of coal for electric power and heat generation. They include pollution abatement measures, economic analyses and fuel engineering in the case of coal. Further sections are dedicated to upgrading procedures such as the gasification, liquefaction and coking of coal. A bibliography informs the reader about further publications available on the subject. (HAG).

1986-04-01

199

Aqueous liquid scintillation counting with fluor-containing nanosuspensions  

Energy Technology Data Exchange (ETDEWEB)

A microemulsion comprised of water, Brij 78, pentanol and styrene into which PPO and bis-MSB had been dissolved was prepared. Polymerization of the styrene resulted in a suspension of fluor-containing polystyrene nanoparticles (<100 nm). After a concentration step, the aqueous nanosuspension was able to detect {sup 14}C with counting efficiencies over 50% of those of a commercially available scintillation cocktail. Monte Carlo calculations demonstrated that the size and concentration of the nanoparticles were appropriate for optimum detection efficiency.

2004-06-01

200

A novel CFD/structural analysis of a cross parachute  

Energy Technology Data Exchange (ETDEWEB)

A novel CFD/structural analysis was performed to predict functionality of a cross parachute under loadings near the structural limits of the parachute. The determination of parachute functionality was based on the computed structural integrity of the canopy and suspension lines. In addition to the standard aerodynamic pressure loading on the canopy, the structural analysis considered the reduction in fabric strength due to the computed aerodynamic heating. The intent was to illustrate the feasibility of such an analysis with the commercially available software PATRAN.

1993-12-31

201

Design of a magnetic braking system  

International Nuclear Information System (INIS)

A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted magnetic flux is within ...

2006-09-01

202

Preliminary Investigations of Joining Technologies for Attaching Refractory Metals to Ni-Based Superalloys  

International Nuclear Information System (INIS)

In this study, a range of joining technologies has been investigated for creating attachments between refractory metal and Ni-based superalloys. Refractory materials of interest include Mo-47%Re, T-111, and Ta-10%W. The Ni-based superalloys include Hastelloy X and MarM 247. During joining with conventional processes, these materials have potential for a range of solidification and intermetallic formation-related defects. For this study, three non-conventional joining technologies were evaluated. These included inertia welding, electro-spark deposition (ESD) welding, and magnetic pulse welding (MPW). The developed inertia welding practice closely paralleled that typically used for the refractory metals alloys. Metallographic investigations showed that forging during inertia welding occurred predominantly on the refractory metal side. It was also noted that at least some degree of forging on the Ni-based superalloy side of ...

2006-01-20

203

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

204

Magnetic fluctuation measurement in Sino United Spherical Tokamak plasma  

International Nuclear Information System (INIS)

To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)

2007-07-01

205

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...

1999-04-01

206

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

207

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

208

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We ...

2005-04-01

209

Magnetic properties of materials  

Energy Technology Data Exchange (ETDEWEB)

A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)

2000-08-15

210

Magnetic flocculation and filtration  

Energy Technology Data Exchange (ETDEWEB)

A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.

1996-10-01

211

NASA Information Technology Requirement Main Menu  

Science.gov (United States)

Headquarters Centrally-Funded Information Technology (IT) Resource Allocation .... Information Technology Policy Formulation Process ...

212

Information Technology (IT) Management: The Clinger-Cohen ...  

Science.gov (United States)

... Information Technology (IT) Management: ... The role of information technology figures prominently in the Homeland Security Act of 2002. ...

2005-02-03

214

JPRS Report, Science Technology, Japan.  

Science.gov (United States)

This is Japan Report with Science and Technology. It contains the issues with different topics on biotecnology, defense industry, nuclear engineering, Marine technology, science and technology policy.

1988-01-01

216

Information Technology Research (ITR) for National Priorities  

Science.gov (United States)

Information Technology Research for National Priorities (ITR) Fiscal Year 2004 Announcement ... the Information Technology Research (ITR) Program is focusing on Information Technology Research in ...

217

Dr Liu Yanhua, Deputy Minister of Science and Technology, Ministry of Science and Technology, People's Republic of China  

CERN Multimedia

Dr Liu Yanhua, Deputy Minister of Science and Technology, Ministry of Science and Technology, People's Republic of China

2004-01-01

218

Bioline International  

Indian Academy of Sciences (India)

- technology moving forward with new developments ...

219

Reduced-aspect-ratio stellarator reactors  

Energy Technology Data Exchange (ETDEWEB)

The extent to which the size of a modular stellarator reactor may be reduced is investigated by means of an analytic model of the reactor. The various means employed include varying the blanket/shield thickness, the power output and the wall loading. An optimum design is found, the major radius of which tends to be insensitive to changes in these quantities, although a decrease in the power output leads to a rather smaller decrease in reactor dimensions, as would be expected. Varying the plasma beta at fixed (iota/2..pi..)/sup 2/epsilon or, alternatively, increasing the rotational transform per field period, may, however, allow configurations with fewer field periods to be accessed which have a substantially smaller major radius than the 'standard case' adopted. The magnetics of various configurations required by the model are checked by field line following and the performance claimed is shown to be relatively easily achieved. Costs of two ...

1984-01-01

220

Positive pulsed corona discharge process for simultaneous removal of SO{sub 2} and NO{sub x} from iron-ore sintering flue gas  

Energy Technology Data Exchange (ETDEWEB)

The authors investigated the application of pulsed corona discharge process to the removal of SO{sub 2} and NO{sub x} from industrial flue gas of an ioron-ore sintering plant. This study was performed on a pilot scale, which is the most advanced demonstration of this process. The flow rate of 5000 m{sup 3}/h of the flue gas was successfully treated. The electrode structure of the corona reactor is the same with that of conventional electrostatic precipitator. The authors made use of magnetic pulse compression technology to produce repetitive high voltage pulse. Pulse width (full width at half maximum) was reduced to less than 1 {micro}s by connecting a resister in parallel with the corona reactor. An inductor was added to the resister in series to minimize the loss by restricting the current flowing through the resister. By this way, they were able to deliver pulse power with peak voltage of 110 kV and peak current of 2.3 kA to the corona ...

1999-08-01

221

Multiple-element eddy current probes for enhanced inspection  

Energy Technology Data Exchange (ETDEWEB)

Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe design is multiple ...

1993-07-01

222

Magnetic fusion reactor economics  

Energy Technology Data Exchange (ETDEWEB)

An almost primordial trend in the conversion and use of energy is an increased complexity and cost of conversion systems designed to utilize cheaper and more-abundant fuels; this trend is exemplified by the progression fossil fission {yields} fusion. The present projections of the latter indicate that capital costs of the fusion ``burner`` far exceed any commensurate savings associated with the cheapest and most-abundant of fuels. These projections suggest competitive fusion power only if internal costs associate with the use of fossil or fission fuels emerge to make them either uneconomic, unacceptable, or both with respect to expensive fusion systems. This ``implementation-by-default`` plan for fusion is re-examined by identifying in general terms fusion power-plant embodiments that might compete favorably under conditions where internal costs (both economic and environmental) of fossil and/or fission are not as great as is needed to justify the contemporary vision for fusion power. ...

1995-12-01

223

In situ Investigation of the Silver-CTAB system  

Energy Technology Data Exchange (ETDEWEB)

Recent research has shown that biologically inspired approaches to materials synthesis and self-assembly, hold promise of unprecedented atomic level control of structure and interfaces. In particular, the use of organic molecules to control the production of inorganic technological materials has the potential for controlling grain structure to enhance material strength; controlling facet expression for enhanced catalytic activity; and controlling the shape of nanostructured materials to optimize optical, electrical and magnetic properties. In this work, we use organic molecules to modify silver crystal shapes towards understanding the metal-organic interactions that lead to nanoparticle shape control. Using in situ electrochemical AFM (EC-AFM) as an in situ probe, we study the influence of a cationic surfactant cetyltrimethylamminobromide (CTAB) on Ag growth during electrochemical deposition on Ag(100). The results show that the organic ...

2007-04-16

224

High voltage high brightness electron accelerator with MITL voltage adder coupled to foilless diode  

International Nuclear Information System (INIS)

The design and analysis of a high brightness electron beam experiment under construction at Sandia National Laboratory is presented. The beam energy is 12 MeV, the current 35 endash 40 kA, the rms radius 0.5 mm, and the pulse duration FWHM 40 ns. The accelerator is SABRE [J. Corley, J. A. Alexander, P. J. Pankuch, C. E. Heath, D. L. Johnson, J. J. Ramirez, and G. J. Denison, in Proceedings of the Eighth International IEEE Pulsed Power Conference, San Diego, California, 1991 (IEEE, New York, 1991), p. 920], a pulsed inductive voltage adder, and the electron source is a magnetically immersed foilless diode. This experiment has as its goal to stretch the technology to the edge and produce the highest possible electron current in a submillimiter radius beam. copyright 1996 American Institute of Physics.

1995-10-13

225

Evaluating the cytotoxicity of palladium/magnetite nano-catalysts intended for wastewater treatment  

International Nuclear Information System (INIS)

Palladium/magnetite nanoparticulate catalysts were developed for efficient elimination of halogenated organic pollutants from contaminated wastewater. Particle recovery from treated water can be ensured via magnetic separation. However, in worst-case scenarios, this catalyst removal step might fail, leading to particle release into the environment. Therefore, a toxicological study was conducted to investigate the impact of both pure magnetite and palladium/magnetite nanoparticle exposure upon human skin (HaCaT) and human colon (CaCo-2) cell lines and a cell line from rainbow trout gills (RTgill-W1). To quantify cell viability after particle exposure, three endpoints were examined for all tested cell lines. Additionally, the formation of reactive oxygen species was studied for the human cells. The results showed only minor effects of the particles on the tested cell systems and support the assumption that palladium/magnetite nano-catalysts can be implemented for a ...

2010-01-01

226

Development of 40m SANS and Its Utilization Techniques  

Energy Technology Data Exchange (ETDEWEB)

Small angle neutron scattering (SANS) has been a very powerful tool to study nanoscale (1-100 nm) bulk structures in various materials such as polymer, self assembled materials, nano-porous materials, nano-magnetic materials, metal and ceramics. Understanding the importance of the SANS instrument, the 8m SANS instrument was installed at the CN beam port of HANARO in 2001. However, without having a cold neutron source, the beam intensity is fairly low and the Q-range is rather limited due to short instrument length. In July 1, 2003, therefore, the HANARO cold neutron research facility project was launched and a state of the art 40m SANS instrument was selected as top-priority instrument. The development of the 40m SANS instrument was completed as a joint project between Korea Advanced Institute of Science and Technology and the HANARO in 2010. Here, we report the specification of a state of art 40m SANS instrument at HANARO

2010-06-15

227

Authentication via wireless networks  

CERN Document Server

Personal authentication is an important process we encounter almost every day; when we are logging on a computer, entering a company where we work, or a restricted area, when we are using our plastic credit cards to pay for a service or to complete some other financial transaction, etc. In each of these processes of personal authentication some kind of magnetic or optical token is required. But by using novel technologies like mobile computing and wireless networking, it is possible to avoid carrying multitude of ID cards or remembering a number of PIN codes. Article shows how to efficiently authenticate users via Personal Area Networks (PAN) like Bluetooth or IrDA using commonplace AES (Rijndel) or MD5 encryption. This method can be implemented on many types of mobile devices like Pocket PC PDA with Windows CE (Windows Mobile 2003) real-time operating system, or any other customized OS, so we will explain all components and key features of ...

2007-01-01

228

An economic assessment of the application of superconductor technology to magnetic-levitation trains in Oklahoma  

International Nuclear Information System (INIS)

Specific objectives were to: (1) develop and refine a methodology that can be used to evaluate the feasibility of MAG-LEV trains; (2) apply this methodology to the state of Oklahoma. The methodology is based on an aggregate econometric demand model and mathematical programming. A city-pair network is constructed to evaluate alternative MAG-LEV routes between Oklahoma City and nine other cites in and out of the state of Oklahoma. Results obtained from the aggregate econometric demand model indicates that MAG-LEV trains would attract significant ridership along different types of origin-destination routes. All nine corridors exhibit induced demand for MAG-LEV trains as well as attracting riderships from other modes. Based on the results of both single and multiobjective LP models, fixed-capital-cost requirements and annual operating cost for each of the above corridors are estimated, and by using different scenarios for discount rates, both costs and revenue were converted to annual ...

229

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...

2000-03-21

230

A conceptual design study of superconducting proton linac for Neutron Science Project. 1  

Energy Technology Data Exchange (ETDEWEB)

The Neutron Science Project at Japan Atomic Energy Research Institute has been proposed for the research of nuclear transmutation technology and the basic science with a spallation neutron source. The project calls for an 8MW proton linac which accelerates 5.3mA average current cw and pulsed beams up to 1.5GeV. The superconducting (SC) rf-cavity is the main option for the energy part from 100MeV to 1.5GeV because by using the SC structure, less power is consumed in cw operation than by using a normal conducting (NC) structure. A conceptual design study of the superconducting proton linac is reported. The SC linac is composed of 8 {beta} sections. Each section has the identical 5-cell cavities with the surface peak field of 16MV/m. The total number of cavities is 284, and the length of the SC linac is 690m. The lattice design is determined with the equipartitioned condition and the matched envelope equations for the minimum emittance growth. The transverse and ...

1998-09-01

231

The effective longitudinal dielectric constant for plasmas in inhomogeneous magnetic fields  

Scientific Electronic Library Online (English)

Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.

2004-09-01

232

Magnetic mirror fusion systems: Characteristics and distinctive features  

Energy Technology Data Exchange (ETDEWEB)

A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.

1987-08-10

233

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

234

Magnetic excitations studied with time-of-flight spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.

1996-11-01

235

Active magnetic regenerator  

Energy Technology Data Exchange (ETDEWEB)

The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.

1982-01-01

236

Device for removing drilling fines from a well head  

Energy Technology Data Exchange (ETDEWEB)

The device for removing drilling fines from the well head includes a support disk encompassing the sucker rod of the drilling machine with frame made in the form of a dish with inner conical surface, and overturned truncated cone located in the dish of the support disk with the formation between them of a ring guide slit. In order to improve the effectiveness of removing the drilling fines and convenience of operation by excluding heavy manual auxiliary operations to clean the well head and to move the device from one well to another, it is equipped with a mechanism for suspension with a drive. The inner conical surface of the dish is equipped with slide blocks, while the overturned truncated cone is equipped with projections. The suspension mechanism is made in the form of a hydrocylinder and two pairs of levers connected in pairs by means of hinges. The hinges of each pair of levers are connected to the hydrocylinder, and the levers are ...

1982-01-01

237

Chaos and bifurcation of a flexible rotor supported by porous squeeze couple stress fluid film journal bearings with non-linear suspension  

Energy Technology Data Exchange (ETDEWEB)

This study presents a dynamic analysis of a flexible rotor supported by two porous squeeze couple stress fluid film journal bearings with non-linear suspension. The dynamics of the rotor center and bearing center are studied. The analysis of the rotor-bearing system is investigated under the assumptions of non-Newtonian fluid and a short bearing approximation. The spatial displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The numerical results show that the stability of the system varies with the non-dimensional speed ratios, the non-dimensional parameter l* and the ...

2008-01-15

238

Chaos and bifurcation of a flexible rotor supported by porous squeeze couple stress fluid film journal bearings with non-linear suspension  

International Nuclear Information System (INIS)

This study presents a dynamic analysis of a flexible rotor supported by two porous squeeze couple stress fluid film journal bearings with non-linear suspension. The dynamics of the rotor center and bearing center are studied. The analysis of the rotor-bearing system is investigated under the assumptions of non-Newtonian fluid and a short bearing approximation. The spatial displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The numerical results show that the stability of the system varies with the non-dimensional speed ratios, the non-dimensional parameter l* and the ...

2008-01-01

239

Implications of high temperature superconductors for power generation  

International Nuclear Information System (INIS)

Superconducting generators for high power applications have been of interest for a number of years. Superconducting generators using low temperature superconductors (LTS) have been manufactured to produce up to 20 MW of electrical power and have been configured in either synchronous alternators which have an AC output that may be subsequently rectified to produce DC and homopolar generators which produce low voltage DC. Typically these generators require scrupulous attention to vacuum integrity for cryogenic insulation at 4.2K and tend to be somewhat fragile because of extensive thermal and magnetic shields that are not required in conventional power generators. Recently, high purity aluminum composites have been developed for a high power AC generator that is cooled by cryogenic hydrogen at 21K. This aluminum generator is very compact and lightweight and is much more robust than a generator made with LTS because extensive thermal and magnetic ...

1991-08-03

240

Nanocrystalline permanent magnets with enhanced properties  

International Nuclear Information System (INIS)

Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

2001-09-23

241

Selective Recovery of Chromium from Precipitates Containing d Elements and Actinides: I. Effects of O2  

Energy Technology Data Exchange (ETDEWEB)

The oxidation of Cr(III) hydroxides, mixed Fe(III)-Cr(III) hydroxides, and specimens of spinel phases NiCr2O4 and Fe(Cr,Fe)2O4 have been investigated in alkaline suspensions under the action of air and pure oxygen (1-3 atm). The rate of reaction increases with increasing alkali concentration, temperature, and oxygen pressure. Pu(IV) fixed on chromium hydroxides is not oxidized by oxygen under these conditions but is retained in the precipitate.

2002-07-15

242

Physical aspects of FGD by-products  

Energy Technology Data Exchange (ETDEWEB)

Air pollution constraints continue to intensify, resulting in solid waste volume increases. An example of this is coal burning power plant flue gas desulfurization by scrubbing. The aqueous suspensions of calcium sulfate hemihydrate or calcium sulfate dihydrate will exceed 200 million tons annually by the year 2000. Disposal of these wastes can have massive environmental effects, due to physical instability and leaching to groundwater. One alternate disposal technique is sulfopozzolanic fixation, converting the FGD waste by addition of fine coal ash and an alkaline earth additive, into a monolithic mass. 6 refs., 17 figs., 3 tabs.

1992-01-01

243

Leak sealing on ancillary cooling circuits of CANDU reactors  

International Nuclear Information System (INIS)

This paper discusses the remote plugging of leaks in inaccessible pipework, with main reference to small leaks which frequently appear in ancillary cooling water circuits of nuclear reactors. Initially developed to cure problems of the pre-stressed concrete pressure vessels of UK reactors, the ZORIC sealant has been used to repair leaking biological shield pipework on six CANDU reactors. ZORIC is based on a water-soluble epoxy resin and an aqueous suspension of a refined mineral clay. This paper describes the evolution of the sealant, the qualification and testing program, and their application to CANDU reactor systems. 2 refs., 6 figs.

1992-11-22

244

In vitro percutaneous absorption of metal compounds.  

Science.gov (United States)

It is well known that contact with metals can be responsible for allergic contact dermatitis; also, there is experimental evidence that nickel ions are readily available on the surface of used coins containing nickel and copper. The aim of this study was to prove that metal powders of nickel (Ni), cobalt (Co) and chromium (Cr) dispersed in synthetic sweat are oxidised into respective ions that can permeate the skin. Suspensions of 5 g of metal powder (Ni, Co and Cr) in 100 mL of synthetic sweat at pH 6.5 were prepared and shaken with a stirring plate at room temperature for 30 min. Human skin membranes were set up in Franz-diffusion cells and 2 mL of the freshly made suspension were applied to the outer surface of the skin for 24h. The appearance of metal ions in the aqueous receptor phase (NaCl 0.9%) was quantified by Electro Thermal Atomic Absorption Spectroscopy (ETAAS). Also, metals ions were analysed using Differential Pulse Polarography ...

2007-02-23

245

Galvanic element with suspended electrode. Galvanisches Element mit suspendierter Elektrode  

Energy Technology Data Exchange (ETDEWEB)

A zinc/air battery is claimed whose performance is improved by omitting separating elements such as diaphragms etc. The cathode and anode spaces are separated by a collector with holes big enough to permit the electrons to pass freely while restraining the anode material. Further, the active material consists of a spherical care of inert material with a zinc coating. Under the zinc coating, the spherical particles have another thin coating of an electropositive material, e.g. nickel. The cell also contains means for circulating the anode suspension.

1984-08-09

246

Comparison of the inhibitory action of KCl and guanidine hydrochloride solutions on montmorillonite swelling  

Science.gov (United States)

This study compares the effectiveness of potassium chloride with guanidine chlorhydrate in the prevention of clay swelling. The results given on various swelling tests on calcic montmorillonite led to the conclusions that (1) guanidine chlorhydrate is more effective than potassium chloride, especially in low concentrations, and (2) water immersion of samples treated by both solutions shows the permanent feature of the inhibitive action of guanidine chlorhydrate in swelling on one hand and the important increase in swelling of immersed samples treated by potassium chloride on the other. The viscosity measure of montmorillonite suspensions, before and after solution ion elimination by dialysis, confirms these observations.

1982-08-01

247

Brittle fracture problem in composite insulators  

Energy Technology Data Exchange (ETDEWEB)

The report traces the documented incidences of brittle fracture in composite suspension insulators for use on high voltage transmission lines, and presents the subsequent investigations. It describes the part played by electrical activity, stress corrosion and humidity, and compares similar failures that have taken place in electric traction insulators. It then goes on to review related work on the humidity effects, stress corrosion, fatigue and partial discharges in glass fiber reinforced plastics in general. The final section summarizes the present understanding of the problem and the various measures taken by different manufactures to avoid it in the future. The need for acceptance criteria in this respect is outlined.

1984-04-01

248

Anticonvulsant properties of selected pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates.  

Science.gov (United States)

A series of pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates was tested for anticonvulsant activity in mice. Eleven of the 15 compounds possessed anticonvulsant activity against pentylenetetrazol-induced convulsions. One compound afforded more anticonvulsant protection against pentylenetetrazol than did trimethadione (67 and 50%, respectively). A suspension of this compound was found to be as effective as a solution in producing anticonvulsant activity. The results suggest that the nitrile analogs were more potent compared to the carbamyl analog due to higher lipid solubility. PMID:7373552

1980-04-01

249

Absorbent for removal of heavy metal impurities from gases and its production  

Energy Technology Data Exchange (ETDEWEB)

This is an adsorbent for removal of heavy metal impurities from gases. In addition to activated charcoal and ferric chloride, it contains a nonwoven dacron filter material to increase the purification level. The filter material has the following mass % composition: 27-54 activated charcoal, 7-35 ferric chloride, the remainder dacron filter material. The activated charcoal is applied to the dacron filter and the resulting mixture is treated with a ferric chloride solution. The activated charcoal is applied in the form of a suspension with a particle diameter of 0.1-0.16 mm. The treatment solution is 3-20% ferric chloride.

1981-03-23

250

Untitled - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...

251

Symptoms of the musculoskeletal system and exposure to magnetic fields in an aluminium plant.  

UK PubMed Central (United Kingdom)

OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available

1995-08-01

252

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.

1985-08-01

253

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be ...

2009-10-19

254

Possible observation of the coexistence of superconductivity and long-range magnetic order in NdRh_4B_4  

International Nuclear Information System (INIS)

The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).

1979-01-01

255

PLASMA JET WELDING, COATING, AND CUTTING: AN ...  

Science.gov (United States)

... 31. New electric forming methods offer potentials for light metals; magnetic forming and plasma forming. ... 3, 25 Magnetic Forming ..... ...

1963-02-01

256

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

Energy Technology Data Exchange (ETDEWEB)

Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-15

257

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

International Nuclear Information System (INIS)

Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-01

258

Mechanism of viscosity effect on magnetic island rotation  

Energy Technology Data Exchange (ETDEWEB)

It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)

2000-04-01

259

Magnetic Properties of Ni Nanoparticles Embedded in ...  

Science.gov (United States)

... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...

2011-05-14

260

Localization of small magnets against a noisy background  

Science.gov (United States)

Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.

2001-05-01

261

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

262

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...

2005-02-01

263
264

Evaluation of Commercial Magnetic Descalers.  

Science.gov (United States)

With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...

1984-01-01

265

Develop Magnetic Coil Design and Manufacturing Capability.  

Science.gov (United States)

... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...

1974-11-01

267

CONTRACT: NAS 8-11811 DESIGN, DEVELOPMENT, MANUFACTURE, AND ...  

Science.gov (United States)

has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magnetic coil is placed over a thin aluminum ...

268

Application of the grazing angle polarized neutron reflectometry to study the magnetism in thin films and stratified media  

Energy Technology Data Exchange (ETDEWEB)

From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...

1992-12-01

269

Anisotropic forming of magnetic powders mixed with ultraviolet resin; Shigaisen koka jushi wo mochiita jisei funmatsu no haiko seikei  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...

1999-01-15

270

Sugar uptake and starch biosynthesis by slices of developing maize endosperm  

Energy Technology Data Exchange (ETDEWEB)

{sup 14}C-Sugar uptake and incorporation into starch by slices of developing maize (Zea mays L.) endosperm were examined and compared with sugar uptake by maize endosperm-derived suspension cultures. Rates of sucrose, fructose, and D- and L-glucose uptake by slices were similar, whereas uptake rates for these sugars differed greatly in suspension cultures. Concentration dependence of sucrose, fructose, and D-glucose uptake was biphasic (consisting of linear plus saturable components) with suspension cultures but linear with slices. These and other differences suggest that endosperm slices are freely permeable to sugars. After diffusion into the slices, sugars were metabolized and incorporated into starch. Starch synthesis, but not sugar accumulation, was greatly reduced by 2.5 millimolar p-chloromercuribenzenesulfonic acid and 0.1 millimolar carbonyl cyanide m-chlorophenylhydrazone. Starch synthesis was dependent on kernel ...

1990-11-01

271

Role of E-cadherin in the induction of apoptosis of HPV16-positive CaSki cervical cancer cells during multicellular tumor spheroid formation.  

Science.gov (United States)

Multicellular tumor spheroids (MCTS) are three dimensional cell culture systems induced by suspension culture. MCTS are widely used in cancer research because of their similarity to solid tumors. CaSki cells are derived from a metastatic cervical cancer containing human papillomavirus 16 (HPV16). Cell death of CaSki cells in MCTS has been previously reported, and our model is used to better characterize the mechanisms of cell death of HPV16-positive keratinocytes. In this study, we found that apoptosis of CaSki cells was induced by suspension culture along with the formation of MCTS after 24 h of incubation. In suspended CaSki cells, monoclonal antibodies blocking E-cadherin function inhibited MCTS formation and suppressed suspension-induced apoptosis in a dose-dependent manner. Western blot for E-cadherin detected upregulation of the authentic 120 kDa band from MCTS of CaSki cells as well as a shorter 100 kDa band. ...

2008-01-01

272

Web inventor wins Millennium Technology Prize  

CERN Multimedia

Web inventor wins Millennium Technology Prize

2004-01-01

273

Rubomycine Production  

International Science & Technology Center (ISTC)

Development of Experimental Large-scale Technology and Creation of Technological Line of Rubomicine Production

274

Plasma Technologies for Fuel Processing  

International Science & Technology Center (ISTC)

Plasma Technologies of Solid Fuels Processing for Power Engineering and Metallurgy

276

Emerging technologies for academic libraries in the digital age  

CERN Document Server

Emerging technologies for academic libraries in the digital age

2009-01-01

277

Coal liquefaction and desulfurization  

Energy Technology Data Exchange (ETDEWEB)

A discussion is presented of the chemistry and technology of coal liquefaction and the physics and technology of coal desulfurization. 31 refs.

1981-01-01

278

Alternative Technologies for Medical Radionuclide Production  

International Science & Technology Center (ISTC)

Creation of Economic Alternative Technologies for Radionuclide Production for Medical Diagnostics and Therapy

279

Magnetic properties of a SmNiSn single crystal  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the ...

2003-04-01

280

Development of magnetic drive packless valves for commercial purpose  

Energy Technology Data Exchange (ETDEWEB)

A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting ...

1995-09-01

281

Challenges in fabrication of 180deg magnet chamber  

International Nuclear Information System (INIS)

180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector ...

2006-11-01

282

AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab  

Energy Technology Data Exchange (ETDEWEB)

Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar ...

1992-09-01

283

Study and analysis of failure modes of the electrolytic capacitors and thyristors, applied to the protection system of the LHC (Large Hadron Collider); Etude et analyse des modes de defaillances des condensateurs electrolytiques a l'aluminium et des thyristors: appliquees au systeme de protection du LHC (Large Hadron Collider)  

Energy Technology Data Exchange (ETDEWEB)

The study presented in this thesis is a contribution about the analysis of failures modes of electrolytic capacitors and thyristors. The studied components are main elements of the protection system of the superconductive magnets of the LHC. The study of the ageing of the electrolytic capacitors has shown that their reliability is strongly related to their technological characteristic. Evolution of their principal indicator of ageing (ESR) can be modeled according to different laws chosen according to their running mode. It appears that the prediction of failure of these components other than that due to wear can be only statistical taking into account the many causes of failure involving various modes of failure. In order to be able to evaluate influence of the ageing of the electrolytic capacitors on a system, simple models taking into account this parameters as well as the effective temperature of the component are proposed. An acceptable ...

2003-07-15

286

The Effect of Static Magnetic Forces on Water Contents and Photosynthetic Pigments in Sweet Basil Ocimum basilicum L. (Lamiaceae)  

International Nuclear Information System (INIS)

Three different magnetic regimes; aerial, surface and buried; each with three different forces, have been used to investigate their effects on the water contents and photosynthetic pigments of sweet basil plants (Ocimum basilicum L.). Two groups of sweet basil seeds, Ocimum basilicum L. have been cultivated, one under normal conditions and the second has been subdivided into three portion (aerial, surface and buried) to examine the effect of different magnetic forces coming from the three directions on the resulted plants. At all directions of magnets, water contents have been significantly affected by the magnetic forces. Chlorophyll A and carotene contents have been affected, as well, according to the three magnetic forces coming from soil surface regime only. Chlorophyll B did not significantly affected by differences magnetic forces in the three regimes, but ...

287

THE APPLICATION OF STEEP PULSE CURRENTS TO THE ...  

Science.gov (United States)

... Title : THE APPLICATION OF STEEP PULSE CURRENTS TO THE ELECTROHYDRAULIC AND MAGNETIC FORMING OF METALS. ...

1966-04-01

294

Recovery Effects of a 180?mT Static Magnetic Field on Bone Mineral Density of Osteoporotic Lumbar Vertebrae in Ovariectomized Rats  

UK PubMed Central (United Kingdom)

The effects of a moderate-intensity static magnetic field (SMF) on osteoporosis of the lumbar vertebrae were studied in ovariectomized rats. A small disc magnet (maximum magnetic flux density 180 mT)...Full Text Available

2011-01-01

295

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

296

Perpendicular magnetic anisotropy of ultrathin FeCo alloy films on Pd(0 0 1) surface: First principles study  

International Nuclear Information System (INIS)

Using the full potential linearized augmented plane wave (FLAPW) method, thickness dependent magnetic anisotropy of ultrathin FeCo alloy films in the range of 1 monolayer (ML) to 5 ML coverage on Pd(0 0 1) surface has been explored. We have found that the FeCo alloy films have close to half metallic state and well-known surface enhancement in thin film magnetism is observed in Fe atom, whereas the Co has rather stable magnetic moment. However, the largest magnetic moment in Fe and Co is found at 1 ML thickness. Interestingly, it has been observed that the interface magnetic moments of Fe and Co are almost the same as those of surface elements. The similar trend exists in orbital magnetic moment. This indicates that the strong hybridization between interface FeCo alloy and Pd gives rise to the large magnetic moment. Theoretically calculated ...

2009-06-01

298

Optimization of soft magnetic properties in Fe-B and Fe-B-Si amorphous alloys obtained by melt spinning method  

International Nuclear Information System (INIS)

In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)

2001-09-23

299

NASA Technical Reports Server - Magnetic forming coil design and ...  

Science.gov (United States)

Site Error There's a problem with your browser or settings. ...

304

Magnetic forming studies  

Science.gov (United States)

Elastodynamic approach to measuring stress-strain relationship of uniaxially stressed wire, and

1967-01-01

306

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

310

Influence of rotation and magnetic field on the minimum mass of a main-sequence star  

Energy Technology Data Exchange (ETDEWEB)

The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.

1980-11-01

327

A STUDY TO DETERMINE THE DEFORMATION ...  

Science.gov (United States)

... crystals and polycrystals. Nevertheless, explosive forming, magnetic forming, etc., are all high-strain-rate processes that ...

1963-04-01

328

A HELICAL MAGNET DESIGN FOR RHIC.  

Energy Technology Data Exchange (ETDEWEB)

Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.

1997-05-12

329

Magnetocaloric and magnetoresistance studies of GdPd{sub 2}Si  

Energy Technology Data Exchange (ETDEWEB)

The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...

2001-01-22

330

Magnetocaloric and magnetoresistance studies of GdPd_2Si  

International Nuclear Information System (INIS)

The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...

2001-01-22

331

High-mode-number ballooning modes in a heliotron/torsatron system: 1, Local magnetic shear  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal force balance in the stellarator-like ...

1996-05-01

332

Effect of the induced magnetic field on peristaltic flow of a couple stress fluid  

Science.gov (United States)

We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and ...

2008-06-01

333

On the temperature dependence of the magnetic excitations  

International Nuclear Information System (INIS)

We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# function shows that ...

2005-07-15

334

Theory of zwitterionic molecular-based organic magnets  

British Library Electronic Table of Contents (United Kingdom)

We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.

2011-01-01

335

Occurrence of magnetism in superconductors  

Science.gov (United States)

We discuss how magnetic phenomena affect superconductivity in simple metals, transition metals and alloys thereof, and dilute Rare-Earth alloys. It is shown both qualitatively and quantitatively that superconductors are sensitive probes for studying itinerant spin excitations, local spin excitations associated with nearly magnetic impurities, the effect of the atomic environment on the stability of local magnetic moments, and the nature of the spin order in Rare-Earth alloys. Also, we discuss how magnetic impurities can be used to study the electronic configuration which is responsible for superconductivity in Laves-phase crystals like A-15 compounds and ..beta..-W crystals, for example.

1970-12-14

336

Magnetic response of ultrathin Fe on MgO: A polarized neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.

1994-11-15

337

Magnetic properties of glasses from geothite industrial wastes recycling (FeOOH)  

International Nuclear Information System (INIS)

It has been carried out the magnetic properties determination for high iron oxide content glasses series obtained from a geothite red mud waste from the zinc hydrometallurgy and dolomite and glass cullet as main raw materials. It has been determined the magnetic susceptibility and magnetization values for the glasses here investigated. The results suggest that the magnetic behaviour are depending on the glass chemical composition, so that glasses can be differently classified like ferrimagnetic, ferromagnetic, superparamagnetic and paramagnetic. (Author) 6 refs.

338

Magnetic fluctuations in paramagnetic Mn{sub 0.81}Ni{sub 0.19}  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluctuations present in the paramagnetic Mn{sub 0.81}Ni{sub 0.19} system have been investigated by measuring inelastic magnetic neutron scattering from a single crystal at temperatures of 450, 585 and 700 K. Antiferromagnetic correlations are observed to be present at all the temperatures studied. The spectral width of the magnetic scattering has been observed to increase with temperature, while the spatial range of the magnetic correlations is seen to decrease as the temperature is raised. The wave-vector-dependent susceptibility is found to follow a Curie-Weiss law near the (1 0 0) position, in agreement with theoretical predictions.

2006-11-15

339

Hydromagnetic rotational braking of magnetic stars  

International Nuclear Information System (INIS)

It is suggested that the magnetic Ap stars can be rotationally decelerated to long periods by the braking action of the associated magnetic field on time scales of order 10"7--10"1"0 years depending on whether the star's dipole field is aligned perpendicular or parallel to the rotation axis. Rotation includes a toroidal magnetic field in the plasma surrounding a star, and the accompanying magnetic stresses produce a net torque acting to despin the star. These results indicate that it is not necessary to postulate mass loss or mass accretion for this purely hydromagnetic braking effect.

340

Correlation between Magnetic Field Quality and mechanical components of the Large Hadron Collider Main Dipoles  

CERN Document Server

The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.

2006-01-01

341

How the Performance of a Superconducting Magnet is affected by theConnection between a small cooler and the Magnet  

Energy Technology Data Exchange (ETDEWEB)

As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the ...

2005-09-08

342

Anisotropic Nd{endash}Fe{endash}B bonded magnets made from HDDR powders (invited)  

Energy Technology Data Exchange (ETDEWEB)

Anisotropic Nd{endash}Fe{endash}B magnet powders can be produced by the hydrogenationdecomposition-desorption-recombination (HDDR) process from Nd{endash}Fe@ xnB{endash}Co{endash}M ({ital M}=Ga, Zr, Nb, Hf, and Ta) alloys. The present status of those HDDR powders and the bonded magnets made from them are reviewed with regards to the powder particle size dependence of their magnetic properties, their magnetic thermal stability, and their magnetization behavior. The results of a mechanistic study on the recombination step are also presented. The magnetic properties of the anisotropic HDDR powder depend relatively little on the powder particle size. Bonded magnets with a density of {approximately}6.20 g/cm{sup 3} and a BH{sub max} of 18.5{endash}20.5 MGOe can be produced from anisotropic HDDR powders with particle sizes of below 300 {mu}m diam. ...

1996-04-01

343

Geothermal Technologies Program: News  

Science.gov (United States)

and Renewable Energy EERE Home | Programs & Offices | Consumer Information Geothermal Technologies Program Search Search Help Geothermal Technologies Program HOME ABOUT...

2011-08-21

344

Fuel Cell Technologies Equipment on Environmental Expert  

Wastenet

... Fuel Cell Technologies Equipment on Environmental Expert Find and compare a variety of fuel cell technologies equipment on the world's largest environmental industry portal. View ...

345

EERE: Geothermal Technologies Program Home Page  

Science.gov (United States)

and Renewable Energy EERE Home | Programs & Offices | Consumer Information Geothermal Technologies Program Search Search Help Geothermal Technologies Program HOME ABOUT...

2011-08-21

346

Department of the  

Wastenet

Waste Technology and Innovation Study Final Report ...Waste Technology and Innovation Study Final Report 21/18569/150554 ...Survey of waste and resource recovery related technology and innovation, including products and product uses

347

Kondo effect and impurity-impurity interaction in (La, Ce)B_6 alloys  

International Nuclear Information System (INIS)

Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY ...

1978-01-01

348

Anti-cancer drug loaded iron-gold core-shell nanoparticles (Fe@Au) for magnetic drug targeting.  

Science.gov (United States)

Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus simulating the human ...

2010-09-01

349

"1"5"1Eu-Moessbauer study of complex magnetism in Eu_2PdSi_3: Effect of Eu"2"+ substitution by Y"3"+ and of high pressure  

International Nuclear Information System (INIS)

With "1"5"1Eu-Moessbauer spectroscopy and other methods the complex magnetic properties of Eu_2PdSi_3, arising from the two crystallographically different lattice sites of the Eu"2"+ ions, have been already studied. Here we study the impact of magnetic dilution of the magnetic Eu"2"+ sites by non-magnetic Y"3"+ ions. A previous specific heat study has found reduced magnetic ordering temperatures with strong indication of disorder effects like in magnetic spin glasses. Here we provide from "1"5"1Eu-Moessbauer spectroscopy detailed information of the impact of Y"3"+ substitution on the magnetic properties of the two lattice sites, well distinguishable in the "1"5"1Eu-spectra. Since the substitution of the larger Eu"2"+ ions by the smaller Y"3"+ ions is connected with a lattice contraction, we also applied high pressure to the Eu_2PdSi_3 sample ...

2010-03-01

352

Training for New Manufacturing Technologies.  

Science.gov (United States)

Examines the effects of computer-based manufacturing technologies on employment opportunities and job skills. Describes the establishment of the Industrial Technology Institute in Michigan to develop and utilize advanced manufacturing technologies, and the institute's relationship to the state's community colleges. Reviews lessons learned from interinstitutional cooperation. Highlights future challenges. (DMM)

1987-12-01

353

Surface Decontamination by Solution  

International Science & Technology Center (ISTC)

Development of Technology for Metal Surface Decontamination in Aqueous Solutions

357

Geothermal Energy Research and Development Program; Project Summaries  

Energy Technology Data Exchange (ETDEWEB)

This is an internal DOE Geothermal Program document. This document contains summaries of projects related to exploration technology, reservoir technology, drilling technology, conversion technology, materials, biochemical processes, and direct heat applications. [DJE-2005

1994-03-01

361

48 CFR 352.239-72 - Security requirements for Federal information technology resources.  

Science.gov (United States)

...requirements for Federal information technology resources. 352.239-72...requirements for Federal information technology resources. As prescribed...Requirements for Federal Information Technology Resources (January...

2010-10-01

362

48 CFR 2452.239-71 - Information Technology Virus Security.  

Science.gov (United States)

... 2010-10-01 true Information Technology Virus Security. 2452...Clauses 2452.239-71 Information Technology Virus Security. As prescribed...the following clause: Information Technology Virus Security (FEB...

2010-10-01

363

48 CFR 1252.239-71 - Information technology security plan and accreditation.  

Science.gov (United States)

...2010-10-01 false Information technology security plan and accreditation...Clauses 1252.239-71 Information technology security plan and accreditation...following provision: Information Technology Security Plan and...

2010-10-01

364

45 CFR 170.210 - Standards for health information technology to protect electronic health information created...  

Science.gov (United States)

...2010-10-01 false Standards for health information technology to protect electronic health information...DEPARTMENT OF HEALTH AND HUMAN SERVICES HEALTH INFORMATION TECHNOLOGY HEALTH INFORMATION TECHNOLOGY STANDARDS, IMPLEMENTATION...

2010-10-01

365

Resistivity, Hall effect, and magnetic susceptibility of UPd_2Si_2  

International Nuclear Information System (INIS)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

366

Resistivity, Hall effect, and magnetic susceptibility of UPd[sub 2]Si[sub 2  

Energy Technology Data Exchange (ETDEWEB)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

1993-12-15

367

Recycler model magnet test on temperature compensation for strontium ferrite  

Energy Technology Data Exchange (ETDEWEB)

The Recycler ring magnet will be made of Strontium ferrite permanent magnets. A strontium ferrite permanent magnet without compensation has a temperature coefficient of -0.2 % in dB/dT. To compensate this effect, we are utilizing 30 % Ni 70 % Fe alloy, a temperature compensation ferromagnetic material with a low Curie point. To search for optimum commercially available material and optimum condition, we made a couple of simple model magnets, and tested with several different compensating material. The test results are reported and its optimal conditions are shown. Several different configurations were tested including a possible 2 kG magnet configuration.

1995-10-01

368

Large specific absorption rates in the magnetic hyperthermia properties of metallic iron nanocubes  

CERN Document Server

We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large heating power.

2010-01-01

369

Itinerant magnetism of Gd_xLa_1_-_xMSi (M=Fe, Co) compounds  

International Nuclear Information System (INIS)

The magnetic properties of polycrystalline and single crystalline rare earth transition metal silicides Gd_xLa_1_-_xMSi (M =Fe, Co) were investigated. Magnetic measurements have been made in static magnetic fields up to 13 kOe and in pulsed magnetic fields up to 250 kOe in the temperature range from 4.2 to 350 K. The magnetic susceptibility in the paramagnetic state of all the investigated compounds obeys the Curie-Weiss law except for LaFeSi and LaCoSi. Increase of the La content in Gd_xLa_1_-_xFeSi compounds leads to a decrease of the Curie and Neel temperatures, which can be explained by a decrease of positive exchange interactions. (orig.).

1995-09-01

370

High Tc superconducting magnetic multivibrators for fluxgate magnetic-field sensors  

Science.gov (United States)

Sensitive and quick-response nonlinear inductance characteristics are found for high Tc superconducting (YBa/sub 2/Cu/sub 3/O/sub 7-chi/) disk cores at 77K in which soft magnetic BH hysteresis loops are observed. Various quick response magnetic devices such as modulators, amplifiers and sensors are built using these cores. The magnetizing frequency can be set to more than 20 MHz, which is difficult for conventional ferromagnetic bulk materials such as Permalloy amorphous alloys and ferrite. New quick-response fluxgate type magnetic-field sensors are made using ac and dc voltage sources. The former is used for second-harmonic type sensors, while the latter is for voltage-output multivibrator type sensors. Stable and quick-response sensor characteristics were obtained for two-core type multivibrators.

1989-09-01

371

Effect of magnet sorting using a simple resonance cancellation method on the RMS orbit distortion at the APS injector synchrotron  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.

1993-07-01

372

Effect of On-Chip Magnetic Shielding for TES Microcalorimeters  

British Library Electronic Table of Contents (United Kingdom)

We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...

2008-01-01

373

Design, Performance and Series Production of Superconducting Trim Quadrupoles for the Large Hadron Collider  

CERN Document Server

The Large Hadron Collider (LHC) will be equipped with several thousands of superconducting corrector magnets. Among the largest ones are the superconducting trim quadrupoles (MQTL). These twin-aperture magnets with a total mass of up to 1700 kg have a nominal gradient of 129 T/m at 1.9 K and a magnetic length of 1.3 m. Sixty MQTL are required for the LHC, 36 operating at 1.9 K in and 24 operating at 4.5 K. The paper describes the design features, and reports the measured quench performance and magnetic field quality of the production magnets. The MQTL magnet production is shared between CERN and industry. This sharing is simplified due to the modular construction, common to all twin-aperture correctors.

2006-01-01

374

Trichoderma-fortified compost extracts for the control of choanephora wet rot in okra production  

British Library Electronic Table of Contents (United Kingdom)

The potential of water extracts produced from rice straw (RST) and empty fruit bunch of oil palm (EFB) composts fortified with Trichoderma harzianum for the control of Choanephora wet rot of okra caused by Choanephora cucurbitarum was studied under field conditions. Disease severity was lowest in plants treated with Trichoderma-fortified RST extracts (9.56%) with a disease index of 1, mancozeb (Dithane M-45 (2gl-1 of water), Trichoderma-fortified EFB compost extracts, extracts of RST and EFB, and an aqueous suspension of T. harzianum recorded disease severity values of 10.25%, 19.38%, 37.56%, 53.71% and 56.36%, with a disease index of 1, 1, 2, 3 and 3, respectively. There was a reduction of 85.04% in Choanephora wet rot severity on okra treated with Trichoderma-fortified RST extracts durin...

2008-01-01

375

Thermal cracking of black oil fuel in a mixture with shale  

British Library Electronic Table of Contents (United Kingdom)

The results of studies performed for the development of a new process of the thermal cracking of tar as a suspension with ground Baltic oil shale in order to obtain motor fuel components are reported. The experimental results suggest undoubted advantages of the process over industrial thermal cracking because the deep degradation of tar (the yields of a gasoline fraction with bp to 180?C, middle distillates with bp of 180?360?C, and feedstock for catalytic cracking with bp of 360?520?C were ~12, 43?44, and ~15?16 wt % on an initial tar basis) was achieved upon the single-stage processing of the raw material under relatively mild conditions (5 MPa, 425?C, and a feed space velocity of 1.0 h?1). The resulting coke-like products and V and Ni contained in the raw material were deposited on the ...

2011-01-01

376

Tea catechins prevent contractile dysfunction in unloaded murine soleus muscle: A pilot study  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveExtended periods of muscle disuse, physical inactivity, immobilization, and bedrest result in a loss of muscle mass and a decrease in muscle force, which are accompanied by an increase in oxidative stress. We investigated the effects of the intake of green tea catechins on unloading-induced muscle dysfunction in tail-suspended mice. MethodsTen-week-old male BALB/c mice were fed a purified control diet or a diet containing 0.5% tea catechins for 14 d. Thereafter, the mice were subjected to continuous tail suspension for 10 d. On the final day, muscle mass, contractile force production, antioxidant potential, and carbonylated protein levels were evaluated. ResultsHind limb unloading caused a loss of soleus muscle weight and muscle force. Intake of tea catechins significantly inhibit...

2011-01-01

377

Surface treatment of carbon steel substrates to prevent cathodic delamination  

Energy Technology Data Exchange (ETDEWEB)

Steel structures immersed in seawater are protected from corrosion using cathodic protection systems (sacrificial anodes or impressed current), by paint coatings or by duplex systems in which cathodic protection hinders corrosion at coating's failure sites. The main problem related to those duplex systems is how to avoid cathodic delamination due to the alkalinity generated at cathodic sites. The present paper analyses the effectiveness of red mud suspensions as pre-treatment to avoid cathodic delamination. The study was conducted using mainly electrochemical impedance spectroscopy (EIS). The evolution of the electrode potential with immersion time was also recorded because it concerns the practical aspect of current density necessary to reach the protection potential. The study shows that red mud pre-treatments are effective in avoiding coating's delamination. (author)

2007-10-10

378

Removal of reactive textile dyes (Remazol Brillant Blue R and Remazol Yellow) by surfactant-modified natural zeolite  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this study, surfactant-modified zeolite (SMZ) was used to remove Remazol Brillant Blue R and Remazol Yellow reactive dyes from aqueous solutions. The influences of suspension pH, temperature, agitation rate, and the SMZ dosage on reactive dyes removal and adsorption capacity were investigated by conducting a series of batch adsorption experiments. The adsorption kinetics was tested for pseudo-first-order, pseudo-second order, intraparticle diffusion model, Elovich, and Bangham models, and rate constants of the kinetic models were calculated. Equilibrium isotherms for the adsorption of reactive dyes were analyzed by the Freundlich, Langmuir, Dubinin-Radushkevich, and Tempkin isotherm models. The Langmuir monolayer adsorption capacities of Remazol Brillant Blue R and Remazol Yell...

2011-01-01

379

Radioactivity decontamination efficiency of ceramic filter in an incineration volume reduction system of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of /sup 54/Mn, /sup 59/Fe, /sup 60/Co, /sup 65/Zn and /sup 137/Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10/sup 5/. 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin.

1987-02-01

380

Radioactivity decontamination efficiency of ceramic filter in an incineration volume reduction system of radioactive waste  

International Nuclear Information System (INIS)

The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of "5"4Mn, "5"9Fe, "6"0Co, "6"5Zn and "1"3"7Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10"5. 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin. (author).

381

Prevalence and incidence of depressive and anxious symptoms in couples undergoing assisted reproductive treatment in an Italian infertility department  

British Library Electronic Table of Contents (United Kingdom)

Objective: We have conducted a longitudinal observational study in order to evaluate the prevalence and the incidence of depressive and anxious symptoms in women and men seeking infertility treatment and to analyze associated factors or risk factors for these kinds of disorders. Study design: A total of 1000 consecutive couples that visited our center for the first time were asked to join this study. Depressive and anxious symptoms were assessed with self-rating Zung Depression Scale (ZDS) and Zung Anxiety Scale (ZAS) questionnaires. A second assessment was planned at the time of b HCG dosage (or at the moment of cycle suspension). A standard questionnaire was used to investigate socio-demographic information and the psychological aspects of couples undergoing in vitro fertilization (IVF) ...

2011-01-01

382

Photobioreactor for cultivation and real-time, in-situ measurement of O2 and CO2 exchange rates, growth dynamics, and of chlorophyll fluorescence emission of photoautotrophic microorganisms  

British Library Electronic Table of Contents (United Kingdom)

A detailed knowledge about the dynamics of phytoplanktonic photosynthesis and respiration is crucial for the determination of primary productivity in open oceans as well as for biotechnological applications. The dynamics are best studied in photobioreactors that are able to simulate natural conditions in such, that light can be modulated not only diurnally but also mimicking effects of solar elevation angle from sunrise to sunset, variable cloudiness, light modulation in refractory sun flecks due to water waves, or light intermittence due to turbulent flow in dense suspensions. In addition, high performance photobioreactors ought to be able to monitor in real time photosynthetic and respiratory activities as well as culture growth. Here, we demonstrate performance of a newly designed bench...

2009-01-01

383

Multi walled carbon nanotubes/epilson polylysine nanocomposite with enhanced antibacterial activity  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aims: To develop a new nano composite of multi walled carbon nanotubes (MWNTs) with enhanced antimicrobial activity. Methods and Results: A novel antimicrobial nanocomposite [MWNT epilson polylysine (MEPs)] was synthesized via covalent attachment of epilson polylysine on MWNTs with hexamethylene diisocyanate (HDI) as the coupling agent. UV visible spectra and Fourier transform infrared spectra (FT IR) investigations indicate that MEPs is stable, with epilson polylysine leaching effectively eliminated. When compared to MWNTs, the new nano composite MEPs exhibits enhanced antimicrobial activities. In 20 mg l 1 suspensions, significant increases of 72 1, 64 5 and 69% against Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus can be observed. The deposited film of MEPs...

2011-01-01

384

Monte Carlo simulations incorporating Mie calculations of light transport in tissue phantoms: Examination of photon sampling volumes for endoscopically compatible fiber optic probes  

Energy Technology Data Exchange (ETDEWEB)

Details of the interaction of photons with tissue phantoms are elucidated using Monte Carlo simulations. In particular, photon sampling volumes and photon pathlengths are determined for a variety of scattering and absorption parameters. The Monte Carlo simulations are specifically designed to model light delivery and collection geometries relevant to clinical applications of optical biopsy techniques. The Monte Carlo simulations assume that light is delivered and collected by two, nearly-adjacent optical fibers and take into account the numerical aperture of the fibers as well as reflectance and refraction at interfaces between different media. To determine the validity of the Monte Carlo simulations for modeling the interactions between the photons and the tissue phantom in these geometries, the simulations were compared to measurements of aqueous suspensions of polystyrene microspheres in the wavelength range 450-750 nm.

1996-04-01

385

Method of manufacturing diffusion oxygen or air carbon electrodes  

Energy Technology Data Exchange (ETDEWEB)

Part of the crushed activated charcoal (about 20-50%) designed for manufacture of electrodes is made water repellant with the help of an aqueous suspension of water repelling agent containing 3-15% (preferably 10%) dry substance. After this the remaining part of the activated charcoal and the other additives are mixed with the water repelling part. The plates or tape which is rolled to an assigned thickness are pressed from the obtained mixture. The electrodes obtained by this method have a thin active layer and a porous structure and have good diffusion properties. They can be loaded by currents up to 80 mA/cm/sup 2/ without causing excessive polarization losses, and their service life is greater than or equal to 100 h.

1981-12-31

386

Length-sorted semiconducting carbon nanotubes for high-mobility thin film transistors  

British Library Electronic Table of Contents (United Kingdom)

We have developed a process for chemical purification of carbon nanotubes for solution-processable thin-film transistors (TFTs) having high mobility. Films of the purified carbon nanotubes fabricated by simple drop coating showed carrier mobilities as high as 164 cm2V?1s?1, normalized transconductances of 0.78 Sm?1, and on/off current ratios of 106. Such high performance requires the preparation of a suspension of micrometer-long and highly purified semiconducting single-walled carbon nanotubes (SWCNTs). Our purification process includes length and electronic-type selective trapping of SWCNTs using recycling gel filtration with a mixture of surfactants. The results provide an important milestone toward printed high-speed and large-area electronics with roll-to-roll and ink-jet device fabri...

2011-01-01

387

Inhibition of barium sulfate deposition by polycarboxylates of various molecular structures  

Energy Technology Data Exchange (ETDEWEB)

To establish a relationship between the molecular structure of polycarboxylates and their growth-retarding influence on barium sulfate, seeded-suspension-growth experiments were performed at various inhibitor concentrations and pH values. Two types of polycarboxylates with a molecular structure based on their polyacrylic or maleic acid were studied. The molecular structure of these compounds were varied by particle substitution with monomers containing hydroxyl, amide, and sulfonic acid, as well as hydrophobic groups. Hydrophobic groups are detrimental to good inhibitor performance, whereas the introduction of OH, NH {sub 2}, or SO {sub 3} H groups presents opportunities to enhance the inhibitor effectiveness. The sequence in performance of the compounds on barium sulfate was compared with the sequence formerly obtained for calcium sulfate dihydrate.

1990-02-01

388

Hydro cyclone. Dimensioning and operation; Hidrociclon. Dimensionado y operacion  

Energy Technology Data Exchange (ETDEWEB)

The hydro cyclone is a piece of equipment for separating and/or classifying solids/liquids with a wide variety of applications in different industrial sectors. This article describes the construction and operation of a hydro cyclone to verify the influence of the main size parameters and variables on its concentrating behaviour. The industrial-sized model which was built does not correspond exactly to the engineering designs. During operation, there was a load loss, which did not exceed 30 kPa, as a results of the fact that the suspension flow was unable to circulate with the original dimensions. However, when, for various reasons, the lower diameter was reduced, it proved possible to achieve an efficiency rate of over 95% in the concentration circuit. (Author) 23 refs.

2007-07-01

389

Hybrid insulator - the excellent post insulator for HVAC and HVDC power station  

Energy Technology Data Exchange (ETDEWEB)

A solid layer artificial pollution test was carried out to study the pollution performance of a new type of hybrid station post insulator used in suspension and tensile high voltage transmission lines. The structure of the separated silicone rubber shed and porcelain core hybrid insulator was shown. The new insulator showed excellent pollution performance under both HVAC and HVDC conditions. It also exhibited excellent aging performance in artificial aging tests. The mechanical strength of the hybrid insulator was also better than normal composite insulators. Another advantage revealed was the fact that separated silicone rubber sheds and porcelain core hybrid post insulators are easier to manufacture than normal porcelain post insulators and other hybrid insulators. 5 refs., 6 tabs., 1 fig.

1997-12-31

390

Enhanced inactivation of bacteria by metal-oxide nanoparticles combined with visible light irradiation  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground In recent years nano-metaloxides which easily penetrate into the cells with special interest due to their higher chemical reactivity as compared to that of similar materials in the bulk form. Of particular interest are nano-TiO2 and ZnO, which have been widely used for their bactericidal and anticancerous properties. Purpose The aim of the present study was to examine the bactericidal properties of nano-TiO2 and ZnO combined with visible light on S. aureus and S. epidermitis, known for their high prevalence in infected wounds. Study Using the technique of electron-spin resonance (ESR) coupled with spin trapping, we examined the ability of TiO2 and ZnO nanoparticle suspensions in water to produce reactive oxygen species (ROS) with and without visible light irradiation. Th...

2011-01-01

391

Enhanced antibacterial activity of bifunctional Fe3O4-Ag core-shell nanostructures  

British Library Electronic Table of Contents (United Kingdom)

We describe a simple one-pot thermal decomposition method for the production of a stable colloidal suspension of narrowly dispersed superparamagnetic Fe3O4-Ag core-shell nanostructures. These biocompatible nanostructures are highly toxic to microorganisms. Antimicrobial activity studies were carried out on both Gram negative (Escherichia coli and Proteus vulgaris) and Gram positive (Bacillus megaterium and Staphylococcus aureus) bacterial strains. Efforts have been made to understand the underlying molecular mechanism of such antibacterial actions. The effect of the core-shell nanostructures on Gram negative strains was found to be better than that observed for silver nanoparticles. The minimum inhibitory concentration (MIC) values of these nanostructures were found to be considerably lowe...

2009-01-01

392

Development of the Weapon Borne Sensor parachute system  

Energy Technology Data Exchange (ETDEWEB)

A parachute system was designed and prototypes built to deploy a telemetry package behind an earth-penetrating weapon just before impact. The parachute was designed to slow the 10 lb. telemetry package and wire connecting it to the penetrator to 50 fps before impact occurred. The parachute system was designed to utilize a 1.3-ft-dia cross pilot parachute and a 10.8-ft-dia main parachute. A computer code normally used to model the deployment of suspension lines from a packed parachute system was modified to model the deployment of wire from the weapon forebody. Results of the design calculations are presented. Two flight tests of the WBS were conducted, but initiation of parachute deployment did not occur in either of the tests due to difficulties with other components. Thus, the trajectory calculations could not be verified with data. Draft drawings of the major components of the parachute system are presented.

1998-06-01

393

Couple stress fluid improve rub-impact rotor-bearing system - Nonlinear dynamic analysis  

British Library Electronic Table of Contents (United Kingdom)

This study performs a dynamic analysis of the rub-impact rotor supported by two couple stress fluid film journal bearings. The strong nonlinear couple stress fluid film force, nonlinear rub-impact force and nonlinear suspension (hard spring) are presented and coupled together in this study. The displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The numerical results show that the dynamic behaviors of the system vary with the dimensionless speed ratios, the dimensionless unbalance parameters and the dimensionless parameter, l*. Inclusive of the periodic, sub-harmonic, quasi-periodic and chaotic motions are found in this analysis. The results of this study contribute to a further understanding of the nonlinear dynamics of a rotor-...

2010-01-01

394

Contact lens disinfection by ultraviolet light  

Energy Technology Data Exchange (ETDEWEB)

A 253.7-nm ultraviolet light with an intensity of 1,100 microW/cm2 was tested for its germicidal activity against contact lenses and storage solutions contaminated with various corneal pathogens. The exposure time necessary to reduce a concentration of organisms from 10(6)/ml to less than 10/ml was 30 seconds for Staphylococcus aureus, 60 seconds for Pseudomonas aeruginosa, and 84 seconds for Candida albicans. The time necessary to sterilize a suspension of 10(4)/ml Acanthamoeba polyphaga was less than three minutes with this technique. Four brands of soft contact lenses were exposed to ultraviolet light for over eight hours without changing their appearance, comfort, or refraction.

1989-12-15

395

Atmospheric Gravity Perturbations Measured by Ground-Based Interferometer with Suspended Mirrors  

CERN Document Server

A possibility of geophysical measurements using the large scale laser interferometrical gravitational wave antenna is discussed. An interferometer with suspended mirrors can be used as a gradiometer measuring variations of an angle between gravity force vectors acting on the spatially separated suspensions. We analyze restrictions imposed by the atmospheric noises on feasibility of such measurements. Two models of the atmosphere are invoked: a quiet atmosphere with a hydrostatic coupling of pressure and density and a dynamic model of moving region of the density anomaly (cyclone). Both models lead to similar conclusions up to numerical factors. Besides the hydrostatic approximation, we use a model of turbulent atmosphere with the pressure fluctuation spectrum f^{-7/3} to explore the Newtonian noise in a higher frequency domain (up to 10 Hz) predicting the gravitational noise background for modern gravitational wave detectors. Our estimates show that this could pose ...

2003-01-01

396

A Model for Chlorine Dioxide Delignification of Chemical Pulp  

British Library Electronic Table of Contents (United Kingdom)

A phenomenon based model for chlorine dioxide delignification of chemical pulp is introduced. The pulp suspension environment is modeled using the concept of two liquid phases, one inside and the other external to the fiber wall. Physico-chemical processes taking place during delignification are implemented with thermodynamic, mass transfer and reaction kinetic models. A broad library of chemical reactions is introduced. Inclusion of each reaction is justified. The model response is tested against experimental laboratory delignification results (o-delignified birch pulp). The experimental data consists of kappa number, hexenuronic acid, inorganic oxy-chlorine compound, and organochlorine (AOX, OX) measurements at several time points during five delignification experiments. The model predic...

2010-01-01

397

The Detailing Process Information Technology and NEC ...  

Science.gov (United States)

... Accession Number : ADB323076. Title : The Detailing Process Information Technology and NEC Utilization. Descriptive Note : Final rept. ...

2006-09-01

398

Self-Propagating High-Temperature Synthesis Technologies  

International Science & Technology Center (ISTC)

Development of SHS-technologies for SiC, Si3N4 and Ceramic Composites on Their Basis from Rocks

399

Magnetometer towed array. Innovative Technology Summary Report  

Energy Technology Data Exchange (ETDEWEB)

This document contains information on the above-mentioned technology, including description, applicability, cost, and performance data.

1999-09-01

400

Information Technology Glossary - NASA  

Science.gov (United States)

Information Technology Glossary of Terms. Applets: Programs that run inside net browsers, usually in Java and typically involving modestly interactive ...

401

Human Systems Center Products and Progress.  

Science.gov (United States)

... Page 43. Integrated Audio Technology Demonstrator The Integrated Audio Technology Dem- development for this application is successful. ...

1993-10-01

402

Health Effects from Advanced Combustion and Fuel Technologies  

Energy Technology Data Exchange (ETDEWEB)

This document requires a separate file for the figures. It is for DOE's Office of Vehicle Technologies Annual Report

2010-01-01

403

Considerations in the Design and Development of a Human ...  

Science.gov (United States)

... appropriate. At press time, the laws governing the use of digital audio technology and the technology itself are rapidly changing. ...

1990-09-20

404

COMMUNICATION MEDIA AND EDUCATIONAL TECHNOLOGY AN - NASA Technical ...  

Science.gov (United States)

adaptations of analog audio technology Recent developments in tape cassette technolocy have made Itpossible to provide up to ...

405

Borehole miner. Innovative Technology Summary Report  

Energy Technology Data Exchange (ETDEWEB)

This document contains information on the above-mentioned technology including description, applicability, cost, and performance data.

1999-11-01

406

Planning and Operation of Commercial Application Center  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this R and D project are as follows : First, transferring developed technologies to outside companies and operating technology market to vitalize technology transactions, Second, developing commercial application projects to transfer technologies for commercial purposes and to solve interface problems in commercial applications, Third, enhancing commercial utilizations of developed accelerator and beam utilization technologies, Finally. preparing infra-structures for the development of over 30 venture- businesses based on achieved technologies through the Proton Engineering Frontier Project.

2003-06-15

407

Geothermal program review 16: Proceedings. A strategic plan for geothermal research  

Energy Technology Data Exchange (ETDEWEB)

The proceedings contain 21 papers arranged under the following topical sections: Exploration technology (4 papers); Reservoir technology (5 papers); Energy conversion technology (8 papers); Drilling technology (2 papers); and Direct use and geothermal heat pump technology (2 papers). An additional section contains a report on a workshop on dual-use technologies for hydrothermal and advanced geothermal reservoirs.

1998-12-31

408

7. Kassel symposium on energy systems technology: Renewable energy sources and efficient utilization of energy; 7. Kasseler Symposium Energie-Systemtechnik: Erneuerbare Energien und rationelle Energieverwendung  

Energy Technology Data Exchange (ETDEWEB)

This proceedings volume comprises 17 papers on the following subjects: Methane hydrates, compounds of gas and water; Compressed air stroage gas turbine power plants / Scheduled application for load levelling between varying wind power production and power demand; Modern pumped storage power stations in the GW range - the PSW Goldisthal example; Lead batteries - new developments and future applications; Alkaline battery systems for hybrid electric road vehicles; Lighium systems and their applications; Zinc/air cells; Hydrogen storage - metal hydride storage, compressed gas storage, LNG storage; Carbon nanofibres for hydrogen storage; Double-layer condensers - technology, cost, perslpectives; Supercondensers in motor vehicles; Superconducting magnetic energy stores; Flywheel storage - status report; Decentralized energy storage in the European integrated supply grid - the EU project DISPOWER; Intercontinental integration of power supply - ...

2002-07-01

409

Treatment of low-frequency pulsating magnetic field on amorphous alloy Fe_7_8Si_9B_1_3  

International Nuclear Information System (INIS)

Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe_7_8Si_9B_1_3 were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe_7_8Si_9B_1_3. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase (#alpha#-Fe(Si), the grain size, 2-10 nm) is 3-7%. The temperature rise ...

2007-07-15

410

Temperature dependence of a twofold magnetic behaviour of a nanoscopic metal/silicon hybrid system - a comparison between Ni/Si and Co/Si  

Energy Technology Data Exchange (ETDEWEB)

The investigated hybrid nanocomposite consists of a porous silicon template with electrochemically embedded Ni or Co nanostructures and offers magnetic characteristics which can be tailored by the electrochemical process parameters during fabrication. A twofold magnetic behaviour can be observed, a first one due to the spinmagnetism at magnetic fields below the saturation magnetization of the deposited metals and a second non-saturating term at higher fields (>1 T up to 7 T) above the saturation magnetization. In case of Ni deposited within the pores this non-saturating term shows a paramagnetic characteristic and follows exactly the Curie-Weiss law, whereas for Co/porous silicon samples the temperature dependent magnetization shows some deviations from the Curie Weiss law. In this high field region a difference in the temperature dependence between Ni ...

2009-10-15

411

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system besides the ...

1980-03-01

412

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

413

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

414

Room-temperature magnetic properties of oxy- and carbonmonoxyhemoglobin  

UK PubMed Central (United Kingdom)

The magnetic susceptibility and the density of human oxy-(HbO2) and carbonmonoxyhemoglobin (HbCO) solutions of various concentrations have been measured at room temperature, with pure water...Full Text Available

1978-10-01

415

Residential magnetic fields and childhood leukemia: a meta-analysis.  

UK PubMed Central (United Kingdom)

OBJECTIVES: This article uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies of residential magnetic field...Full Text Available

1998-12-01

416

Print sec333photoindex (256 pages)  

Science.gov (United States)

Electro-Magnet. Antenna Panels Types Simulated Hail Stone Damage A.Panel ...... X-Band Klystron Electro Magnet. 11. I I. 333-6104 AcBc. 333-6105 Color ...

417

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

418

Nature of magnetic coupling between Mn ions in as-grown Ga1-xMnxAs studied by x-ray magnetic circular dichroism  

International Nuclear Information System (INIS)

The magnetic properties of as-grown Ga1-xMnxAs have been investigated by the systematic temperature and magnetic field dependent soft x-ray magnetic circular dichroism (XMCD) measurements in the Mn L2,3 absorption edge region. The XMCD intensity at high temperatures obeys the Curie-Weiss law, but residual spin magnetic moment appears already around 100 K, significantly above Curie temperature (Tc), suggesting that short-range ferromagnetic correlations are developed significantly above Tc. The high-field magnetic susceptibility becomes T-independent below TC, indicating that the AF interaction between the substitutional Mn (Mnsub and interstitial Mn (Mnint) ions, which becomes strong as the Mn concentration x increases, exists and that the amount of the Mnint affects Tc. The present experimental findings should give valuable insight into the inhomogeneous ...

2009-07-01

419

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

420

Magnetic and structural investigation of magnetic thin films with obliquely deposited underlayers  

CERN Document Server

An in-plane uniaxial magnetic anisotropy has been observed in thin Co films normally deposited onto obliquely sputtered Ta and Pt underlayers. Associated with this anisotropy is an augmented easy axis coercivity. The in-plane easy axis is, in most cases, perpendicular to the incident deposition plane. Microstructural results indicate that grains are well connected along the magnetic easy axis but are separated by long continuous voids along the hard axis, which is ascribed to a geometric shadowing effect due to the oblique incidence deposition of the underlayer. Hence, the magnetic anisotropy mimics the film growth anisotropy. It is therefore believed that the observed magnetic properties are due to magnetostatic shape anisotropy effects. In-plane coercivity and anisotropy field are shown to increase with underlayer deposition angle, underlayer thickness and magnetic layer ...

2002-01-01

421

Magnetic and chemical changes in marine sediments  

Energy Technology Data Exchange (ETDEWEB)

A considerable amount of chemical knowledge of marine sediments has been acquired in recent years but has not yet been utilized by paleomagnetists. On the other hand, geochemists are often unaware of the usefulness of numerous magnetic techniques. In this review we try to bridge this gap, and in particular, we outline many of the chemical and magnetic principles that should allow paleomagnetists to better identify and undertand chemical changes that affect the magnetic properties of marine sediments. The chemical principles include those for distinguishing the four major sources of sediments (continental, biological, authigenic/hydrogenous, volcanic/hydrothermal) from one another by determining elemental abundance distributions, as well as for investigating the stabilities of mineral phases relative to changes in pE and pH. The magnetic principles include the effects of authigenesis and diagenesis on ...

1980-05-01

422

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

423

Long-lived states to sustain hyperpolarized magnetization  

UK PubMed Central (United Kingdom)

Major breakthroughs have recently been reported that can help overcome two inherent drawbacks of NMR: the lack of sensitivity and the limited memory of longitudinal magnetization. Dynamic nuclear polarization...Full Text Available

2009-11-03

424

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

425

Epidemiological appraisal of studies of residential exposure to power frequency magnetic fields and adult cancers.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To appraise epidemiological evidence of the purported association between residential exposure to power frequency magnetic fields and adult cancers. METHODS: Literature review and epidemiological...Full Text Available

1996-08-01

426

Epidemiologic studies of electric and magnetic fields and cancer: strategies for extending knowledge.  

UK PubMed Central (United Kingdom)

Epidemiologic research concerning electric and magnetic fields in relation to cancer has focused on the potential etiologic roles of residential exposure on childhood cancer and occupational exposure...Full Text Available

1993-12-01

427

Energetic constraints on the creation of cell membrane pores by magnetic particles.  

UK PubMed Central (United Kingdom)

Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available

1996-08-01

428

Electric and magnetic field exposures for people living near a 735-kilovolt power line.  

UK PubMed Central (United Kingdom)

The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available

1995-09-01

429

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

430

Design of modular coils for a quasi-axisymmetric stellarator with a flexible control of the magnetic field configuration  

Energy Technology Data Exchange (ETDEWEB)

A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a flexibility of the magnetic field configuration is realized. For the case that the rotational transform ...

2002-08-01

431

Design and experimental results on a terawatt magnetically controlled plasma opening switch  

Energy Technology Data Exchange (ETDEWEB)

The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load ...

1998-05-01

432

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

433

A case cohort study of suicide in relation to exposure to electric and magnetic fields among electrical utility workers.  

UK PubMed Central (United Kingdom)

OBJECTIVES--This case cohort study examines whether there is an association between exposure to electric and magnetic fields and suicide in a population of 21,744 male electrical utility workers from...Full Text Available

1996-01-01

434

A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal...  

Science.gov (United States)

Name U.S. Geological Survey A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal Field, Nevada: A Web Site for Distribution of Data by U. S. Geological Survey &...

2011-08-20

435

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

436

Untitled - NASA Technical Reports Server  

Science.gov (United States)

the techniques employed at present, some of which, like magnetic forming and hotdrape forming, are in experimental stages. Published October 1965. ...

438

The Effect of the Temperature to Which the Material is Heated ...  

Science.gov (United States)

... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...

1980-09-01

441

SELECTED LISTING OF ECHNOLOGY UTILIZATION PUBLICATIONS  

Science.gov (United States)

as magnetic forming and hot-drape forming. Details about the 25 techniques discussed incorporate the most recent improvements and ...

444

Read/write characteristics of focused-ion-beam-etched heads for perpendicular magnetic recording media  

International Nuclear Information System (INIS)

The read/write characteristics for perpendicular magnetic recording media of focused-ion-beam (FIB)-etched recording heads were investigated. It was found that the trailing edge of an FIB-etched head produces a higher gradient in the magnetic field perpendicular to the medium than a head which has not been etched. The signal-to-noise ratio of the medium increased with the FIB-etched write gap. A high-Bs and thin pole increased the magnetic field's gradient in the perpendicular direction, resulting in excellent read/write characteristics.

2001-10-01

445

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

446

Nuclear moments of the 11/2"- isomer in "1"8"7Ir  

International Nuclear Information System (INIS)

... excited states iridium 187 isomeric nuclei magnetic fields nuclear electric

447

Nuclear moments and changes in rms-radii of neutron-deficient silver isotopes  

International Nuclear Information System (INIS)

... nuclear electric moments nuclear magnetic moments nuclear radii quadrupole

1987-03-23

448

Nuclear magnetic resonance on oriented XVTa and XXTa  

Energy Technology Data Exchange (ETDEWEB)

XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.

1984-08-01

449

Nature of the magnetic susceptibility of dysprosium. Paramagnetic susceptibility of dysprosium - yttrium alloys  

International Nuclear Information System (INIS)

The paramagnetic susceptibility of single crystals of dysprosium-yttirum alloys is measured in the basal plane and along the hexagonal axis. It is shown that the susceptibility of the alloys obeys the Curie-Weiss law, the effective magnetic moments allong the different directions being the same and the paramagnetic Curie temperatures being different. The difference between the paramagnetic Curie temperatures in the basal plane and along the hexagonal axis is independent of the dysprosium concentration in the alloy. As a comparison with the theoretical models of magnetic anisotropy shows, this is an indication that the magnetic anisotropy of dysprosium - yttrium alloys is of a single-ion nature.

1976-01-01

450

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

451

Methods and instruments for nondestructive testing of the anisotropy of the magnetic properties of ferromagnetic sheet materials (review)  

Energy Technology Data Exchange (ETDEWEB)

This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.

1995-04-01

453

Magnetic structure of Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2  

International Nuclear Information System (INIS)

The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).

455

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

456

Magnetic properties of oxovanadium(IV) complexes with bidentate on donor Schiff bases  

International Nuclear Information System (INIS)

(Feb 1977). Japan Syamal, A. Bombay Univ. (India). Univ. Dept. of Chemical

1977-01-01

457

Magnetic phase diagrams of the TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} systems  

Energy Technology Data Exchange (ETDEWEB)

The a.c. susceptibility and high field magnetization of TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} compounds were investigated up to 140 kOe. The (T, x) magnetic phase diagrams were determined. For both systems, an increase in the Pd content causes a decrease in the Neel temperature and changes the magnetization curves. (orig.)

1995-12-01

458

Magnetic braking in weakly ionized media  

International Nuclear Information System (INIS)

The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.

459

Magnetic Tape Pulse Width to Digital Convertor.  

Science.gov (United States)

... This is achieved by the use of a unique logic circuit employing a plurality of flip-flop devices, multivibrators and AND gates. ...

1976-12-07

460

Magnetic Properties of a Material Used to Estimate Elastic and Plastic Strains of Ferrite?Pearlite Steels  

British Library Electronic Table of Contents (United Kingdom)

The effect of elastic and plastic strains on the magnetic properties of ferrite-pearlite steels has been studied. It has been shown that the sensitivity to elastic-tensile and bending strains is four to five times greater for remnant magnetization than for coercive force. In order to determine the degree of cold plastic deformation of high-carbon steels, a two-parametric testing technique based on the use of remnant magnetization and coercive force was suggested. An MMT-2 device was recommended for measurement of the required parameters.

2005-01-01

461

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

465

Injection and extraction magnets: septa  

CERN Document Server

An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.

2010-01-01

466

Influence of resonant US on H-NMR at application of magnetic nanoparticles  

International Nuclear Information System (INIS)

2010 [1 p.] Germany Repp, Felix El-Miladi, Nouri Hoehl, Christian Jahanbakhsh,

2010-03-21

467

From Rodinia to Gondwana: few paleo magnetic constraints; many speculations  

International Nuclear Information System (INIS)

... Trama; Montevideo (Uruguay) 70 p. GEOSCIENCES geologic history geologic

2001-11-12

470

Domain wall pining in a jointed ferromagnetic nano-wire  

Energy Technology Data Exchange (ETDEWEB)

The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.

2004-05-01

474

Conceptual design of a compact medical synchrotron with a hybrid magnet  

International Nuclear Information System (INIS)

English 2001 p. 178 China Iwashita, Y. Kumada, M. National Institute

2001-09-17

475

CAPACITOR DISCHARGE METAL FORMING  

Science.gov (United States)

... Report Date : JUL 1961. Pagination or Media Count : 39. Abstract : Open-ende Terms: Electrohydraulic forming, Magnetic forming. ...

1961-07-01

476

A preliminary design for a one GHz NMR spectrometer magnet  

International Nuclear Information System (INIS)

The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.

1993-09-20

477

A Profile of Defense Manufacturing Costs and Enabling ...  

Science.gov (United States)

... Casting Explosive forming Forging Electrohydraulic forming Extruding Magnetic forming Rolling Electroforming Drawing Powdered metal forming ...

1992-01-01

478

A GENERAL STUDY OF PROCESSES FOR THE ...  

Science.gov (United States)

... fields, materials can be subjected to energy densities exceeding those realized in high explosives, a fact which forms the basis for magnetic forming ...

1962-11-01

479

Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from ...

2009-03-01

480

Precious Metals in Municipal Solid Waste Incineration Bottom Ash  

Energy Technology Data Exchange (ETDEWEB)

Municipal solid waste incineration (MSWI) bottom ash contains economically significant levels of silver and gold. Bottom ashes from incinerators at Amsterdam and Ludwigshafen were sampled, processed, and analyzed to determine the composition, size, and mass distribution of the precious metals. In order to establish accurate statistics of the gold particles, a sample of heavy non-ferrous metals produced from 15 tons of wet processed Amsterdam ash was analyzed by a new technology called magnetic density separation (MDS). Amsterdam's bottom ash contains approximately 10 ppm of silver and 0.4 ppm of gold, which was found in particulate form in all size fractions below 20 mm. The sample from Ludwigshafen was too small to give accurate values on the gold content, but the silver content was found to be identical to the value measured for the Amsterdam ash. Precious metal value in particles smaller than 2 mm seems to derive mainly from waste ...

2009-04-15

481

Joining of zirconium alloys  

International Nuclear Information System (INIS)

Alloys of zirconium are widely used in various core components of power reactors. Nuclear assemblies require high degree of reliability and integrity for performing in radiation and corrosive atmosphere. The hostile environments of reactor core and inaccessibility for repairs make it mandatory to select only those joining techniques which produce not only superior quality but are also amenable to NDT methods and such other techniques which ensure acceptable performance. The author has worked on various types of welding of zirconium alloys for different applications. Modern techniques in electron beam (EB) welding, resistance welding, GTAW welding and laser welding have been developed for joining Zr alloys components for different types of reactors. Many of these have been standardized and successfully used in production. Several advancements have been made in the welding technologies towards achieving high productivity and increased reliability with economy and ...

2002-09-11

482

Hybrid apparatus for Bose-Einstein condensation and cavity quantum electrodynamics: Single atom detection in quantum degenerate gases  

International Nuclear Information System (INIS)

We present and characterize an experimental system in which we achieve the integration of an ultrahigh finesse optical cavity with a Bose-Einstein condensate (BEC). The conceptually novel design of the apparatus for the production of BECs features nested vacuum chambers and an in vacuo magnetic transport configuration. It grants large scale spatial access to the BEC for samples and probes via a modular and exchangeable ''science platform.'' We are able to produce 87Rb condensates of 5x106 atoms and to output couple continuous atom lasers. The cavity is mounted on the science platform on top of a vibration isolation system. The optical cavity works in the strong coupling regime of cavity quantum electrodynamics and serves as a quantum optical detector for single atoms. This system enables us to study atom optics on a single particle level and to further develop the field of quantum atom optics. We describe the technological modules and the ...

2006-06-01

483

Geologic research of conventional and unconventional hydrocarbon resources. Quarterly report, October 1, 1992--March 1, 1993  

Energy Technology Data Exchange (ETDEWEB)

This report covers the period from October 1, 1992 to March 1, 1993. The overall goals of the program task are to provide a final synthesis of six deep seismic reflection profiles and other geological and geophysical data from the southern Washington Cascades region where a probable extensive deep sedimentary basin has been discovered. This deep sedimentary basin is hypothesized from geological, regional magnetotelluric (MT), gravity, magnetic , and seismic reflection data as described in the American Association of Petroleum Geologists (AAPG) article by Stanley and others (1992). This report analyzed three seismic reflection profiles acquired by the Morgantown Energy Technology Centers in combination with the extensive MT and other data to outline a probable geological model for a thick conductive section of rocks in the southern Washington Cascades (called the Southern Washington Cascades conductor, SWCC). Earlier MT models suggested that the ...

1993-03-02

484

Enzyme-induced growth of silver nanoparticles studied on single particle level  

Energy Technology Data Exchange (ETDEWEB)

Based on their interesting properties, metal nanoparticles show the potential as an analytical tool in electronic (Burmeister et al. 2004), optical (Yguerabide and Yguerabide 1998), and catalytic applications (Liu 2006). Their characteristics depend on the composition, shape, and size of the single particles. These various properties are utilized in many different approaches such as optics, magnetics (Lang et al. 2007), and laser technology (Csaki et al. 2007). We investigated an alternative method for the synthesis of nanoparticles. In this case, an enzyme, horseradish peroxidase, induces a silver deposition and replaces a metal nanoparticle as the reaction seed. Depending on the reaction time, we could obtain particles in a range of few nanometers up to more than 250 nm. For a better understanding of the enzymatic silver deposition process, the silver particles produced by this process were analyzed by SEM, TEM, and atomic force microscopy ...

2009-05-15

485

Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy  

International Nuclear Information System (INIS)

High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 deg. C voxel-wise SDT) were acquired in an ...

2008-11-21

486

Electron cyclotron heating  

International Nuclear Information System (INIS)

Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented by heating in the ...

487

Design of a propulsion system with double-layer power capacitors and soft-switched converters for a hybrid automobile  

Energy Technology Data Exchange (ETDEWEB)

This thesis examines the design of a propulsion system for a series hybrid vehicle and includes the study of an energy storage unit using double-layer capacitors and a lightweight soft-switched converter system, and two new components in series hybrid vehicles. The development of environmentally sustainable vehicles is more urgent now given the fact that pollution levels are ever increasing. No electric vehicle has yet been developed that can compete with a normal vehicle based only on internal combustion engines. The dilemma lies in the difficulty of storing the amount of energy needed and supply it a high power levels. An attractive and viable option to reducing pollution and maintaining good performance may lie in hybrid electric-powered vehicles. The double-layer power capacitors are an interesting option because of their high power density and long lifetime. The devices are new and assembling large energy storage units must be thoroughly examined before using them in actual ...

2001-07-01

488

Coilgun Launcher for Nanosatellites  

Energy Technology Data Exchange (ETDEWEB)

Nanosatellite space launches could significantly benefit from an electrically powered launch complex, based on an electromagnetic coil launcher. This paper presents results of studies to estimate the required launcher parameters and some fixed facility issues. This study is based on electromagnetic launch, or electromagnetic gun technology, which is constrained to a coaxial geometry to take advantage of the efficiency of closely-coupled coils. A baseline configuration for analysis considers a payload mass of 10 kg, launch velocity of 6 km/s, a second stage solid booster for orbital insertion, and a payload fraction of about 0.1. The launch facility is envisioned as an inclined track, 1-2 km in length, mounted on a hillside at 25 degrees aimed in the orbital inclination of interest. The launcher energy and power requirements fall in the range of 2000 MJ and 2 MW electric. This energy would be supplied by 400 modules of energy storage and ...

1999-03-23

489

Application of Bayer red mud for iron recovery and building material production from alumosilicate residues  

Energy Technology Data Exchange (ETDEWEB)

Red mud is a solid waste produced in the process of alumina extraction from bauxite. In this paper, recovery iron from Bayer red mud was studied with direct reduction roasting process followed by magnetic separation, and then building materials were prepared from alumosilicate residues. After analysis of chemical composition and crystalline phase, the effects of different parameters on recovery efficiency of iron were carried out. The optimum reaction parameters were proposed as the following: ratio of carbon powder: red mud at 18:100, ratio of additives: red mud at 6:100, roasting at 1300 deg. C for 110 min. With these optimum parameters, total content of iron in concentrated materials was 88.77%, metallization ratio of 97.69% and recovery ratio of 81.40%. Then brick specimens were prepared with alumosilicate residues and hydrated lime. Mean compressive strength of specimens was 24.10 MPa. It was indicated that main mineral phase transformed from nepheline ...

2009-01-15

490

Stability of superconducting ISABELLE dipole magnets  

Energy Technology Data Exchange (ETDEWEB)

The concept of the minimum propagating zone (MPZ) is used to examine the causes of quenches in ISABELLE cosine theta superconducting dipole magnets. The size of disturbances large enough to exceed the MPZ and initiate quenches is estimated and compared with the size of disturbances which may be produced in the magnets. A suggestion for reducing the size of these disturbances through individual support of the coil block is outlined.

1981-04-01

491

Self-simulating motion of an ionized gas expelled by a magnetic piston  

Energy Technology Data Exchange (ETDEWEB)

The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.

1980-01-01

492

Search for magnetic rotation in {sup 202}Pb and {sup 203}Pb  

Energy Technology Data Exchange (ETDEWEB)

High-spin states in {sup 202}Pb and {sup 203}Pb have been investigated by in-beam {gamma}-ray spectroscopy following the reaction {sup 198}Pt({sup 9}Be,xn). A search for magnetic rotational bands in these isotopes confirmed one of the two bands previously assigned to {sup 202}Pb and revealed a new band in this isotope. No evidence for magnetic rotation has been found in {sup 203}Pb. (orig.)

2000-11-01

493

Multidipole magnetic fields for plasma confinement  

Energy Technology Data Exchange (ETDEWEB)

Plasma confinement by permanent magnets has been studied. An analytic formula for the field of a single bar magnet has been obtained. Generalization to various configurations of multidipole fields has also been found. Any two-dimensional field may now be completely described by a simple function of complex variables in closed form. Vector potential has also been obtained by integrating over a prescribed Riemann surface. The confinement of plasma by multidipole fields then becomes obvious through conservation principles.

1983-07-01

494

Methods of reducing magnetic field near the transmission lines  

International Nuclear Information System (INIS)

Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.

2003-01-01

495

Magnetic properties of FeSi with cobalt impurities  

Energy Technology Data Exchange (ETDEWEB)

Results of experimental researches of impurity level crystals Fe1-xCoxSi are presented in this article. Magnetic properties in a temperature range up to T {<=} 1000 K are analyzed. It was established that with Co impurities increasing origin of magnetic ordering exists at low temperatures. At high temperatures a high temperature maximum of susceptibility of nominally pure iron monosilicide crystal is observed.

2010-01-01

496

Kondo effect in the systems of magnetic trimers on a metal surface  

International Nuclear Information System (INIS)

Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)

2010-11-01

497

Effect of heat treatment on the properties of Metglas foils, and laminated magnetoelectric composites made thereof  

British Library Electronic Table of Contents (United Kingdom)

Annealing of magnetostrictive Metglas foils, subsequently incorporated into laminated Metglas/Pb(Zr, Ti)O3 magnetoelectric (ME) composites, is shown to result in improved magnetic properties, as well as ME coefficients. Annealing of the foils at 350 ?C resulted in partial crystallization, without oxidation or magnetic cluster formation that would reduce the magnetization. Laminate composites made with these annealed Metglas foils had improved ME coefficients.

2011-01-01

498

Current applications of magnetic resonance in coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)

1982-01-01

499

Conductance quantization in ferromagnetic Ni nano-constriction  

Energy Technology Data Exchange (ETDEWEB)

The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.

2002-02-01

500

Bacterial cultivation in high magnetic fields by 7-tesla superconducting magnet; 7T chodendo magnet ni yori hasseishita kojiba ni okeru biseibutsu no baiyo  

Energy Technology Data Exchange (ETDEWEB)

Although a large number of studies on effects of magnetic fields on living organisms was reported, no definite results were obtained in many cases because the related conditions are non-uniform and uncertain, such that the uniform magnetic space is smaller than test samples, and temperature control is insufficient. Therefore, the present study developed a microorganism cultivation system that is applied with a 7-T superconducting magnet. This system has the following features: it generates homogeneous magnetic fields of 0.5 to 7 T {plus_minus} 0.5% in the space with a diameter of 100 mm and a length of 200 mm in a normal temperature bore (with a diameter of 160 mm); it can cultivate microorganisms aerobically at temperatures of 10 to 70{degree}C {plus_minus} 0.1{degree}C; it can perform the cultivation simultaneously with a control cultivation in a small magnetic field weaker than ...

1994-12-20