WorldWideScience
1

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

2

A preliminary design for a one GHz NMR spectrometer magnet  

International Nuclear Information System (INIS)

The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.

1993-09-20

3

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

4

The magnetic spectrometer PAMELA for the study of cosmic antimatter in space  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.

1995-09-01

5

PBAR: A superconducting magnet spectrometer for cosmic ray antiproton studies  

Energy Technology Data Exchange (ETDEWEB)

We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).

1990-09-15

6

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

7

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

8

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

9

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the ...

2004-12-15

10

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...

2000-03-21

11

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

12

Revision I July 29, 2009 - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

MIL-STD-129. N. 5/15/97. Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 ...

13

Project Technical ... - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 D. Notice 1. 12/15/99. 05/10/ 02 ...

14

AMS Project Plan - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Feb 19, 2009 ... Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1. D. Notice 1 ...

16

A driving system for Moessbauer spectrometer  

International Nuclear Information System (INIS)

The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.

17

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

18

Feasibility study of large combined function magnets for the Jefferson lab 12 GeV upgrade  

CERN Document Server

The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm ...

2005-01-01

19

Remote Sensor Systems for Unmanned Planetary Missions  

Science.gov (United States)

instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...

20

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

21

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

22

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

23

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the ...

2010-11-11

24

Progress of magnetic-suspension systems and magnetic bearings in the USSR  

International Nuclear Information System (INIS)

This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.

1992-05-01

25

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

26

The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers ...

2009-01-01

27

Measurement of the antiproton/proton ratio at few-TeV energies with the ARGO-YBJ experiment  

CERN Document Server

Cosmic ray antiprotons provide an important probe for the study of cosmic-ray propagation in the interstellar space and to investigate the existence of Galactic dark matter. Cosmic rays are hampered by the Moon, therefore a deficit of cosmic rays in its direction is expected (the so-called "Moon shadow"). The Earth-Moon system acts as a magnetic spectrometer. In fact, due to the geomagnetic field the center of the Moon shifts westward by an amount depending on the primary cosmic ray energy. Paths of primary antiprotons are therefore deflected in an opposite sense in their way to the Earth. This effect allows, in principle, the search of antiparticles in the opposite direction of the observed Moon shadow. The ARGO-YBJ experiment, in stable data taking since November 2007 with an energy threshold of a few hundreds of GeV, is observing the Moon shadow with high statistical significance. Using about 1 year data, an upper limit ...

2009-01-01

28

Launch of the Space experiment PAMELA  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the ...

2007-01-01

29

Design of a magnetic braking system  

International Nuclear Information System (INIS)

A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are ...

2006-09-01

30

In-place testing of HEPA filter systems by the single-particle, particle-size spectrometer method  

Energy Technology Data Exchange (ETDEWEB)

This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.

1981-12-01

31

Magnetic mirror fusion systems: Characteristics and distinctive features  

Energy Technology Data Exchange (ETDEWEB)

A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.

1987-08-10

32

International Symposium on Magnetic Suspension Technology. Part 2  

International Nuclear Information System (INIS)

In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.

1991-08-19

33

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

34

Moessbauer investigation of the magnetic anisotropy and electronic structure of a metallic glass  

International Nuclear Information System (INIS)

The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).

35

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

36

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

37

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

38

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

39

COBE confounds the cosmologists  

Energy Technology Data Exchange (ETDEWEB)

The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.

1990-03-01

40

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the ...

2004-11-01

41

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of ...

1981-11-11

42

Expert overseer for mass spectrometer system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of ...

1991-06-18

43

Expert overseer for mass spectrometer system  

International Nuclear Information System (INIS)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of ...

1989-04-04

44

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The ...

1985-08-01

45

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

46

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement ...

1985-07-03

47

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.

51

A polarized neutron reflectometry study of the spin glass freezing in a 29 nm thick AuFe film  

Energy Technology Data Exchange (ETDEWEB)

We performed polarized neutron reflectometry (PNR) experiments on a 29 nm thick Au{sub 93}Fe{sub 7} film in a temperature range from 295 K down to 2 K in a vertical magnetic field up to 6 T. These high-field experiments were performed on the C5 spectrometer in Chalk River, Canada, using a split-pair cryomagnet. The magnetization as determined by PNR can be described with a Brillouin function from 295 K down to 50 K assuming the magnetic moment of isolated Fe atoms, i.e. 4{mu}{sub B} per Fe atom. Below 50 K the onset of the spin-glass freezing is observed as a strong deviation from this Brillouin type behavior of isolated atoms.

2007-07-15

52

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer  

CERN Document Server

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer

1998-01-01

53

Modifications to the rotating crystal spectrometer  

International Nuclear Information System (INIS)

... bf3 counters data multi-channel analyzers multivibrators neutron spectrometers

54

Symptoms of the musculoskeletal system and exposure to magnetic fields in an aluminium plant.  

UK PubMed Central (United Kingdom)

OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available

1995-08-01

55

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

57

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of ...

2004-04-01

58

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

59

Magnetic excitations studied with time-of-flight spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.

1996-11-01

60

Continuous-wave cavity ringdown spectroscopy of the Formula Not Shown Meinel system (2,1) band  

British Library Electronic Table of Contents (United Kingdom)

The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...

2008-01-01

61

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package ...

1980-03-01

62

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used ...

2005-04-01

63

High-mode-number ballooning modes in a heliotron/torsatron system: 1, Local magnetic shear  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal ...

1996-05-01

64

Multipass laser mass spectrometer with extreme jet-cooled pulsed gas  

International Nuclear Information System (INIS)

We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes ...

2006-09-01

65

Spectroscopy of neutron-rich Fe isotopes populated in the "6"4Ni+"2"3"8U reaction  

International Nuclear Information System (INIS)

The neutron-rich Fe isotopes from A=61 to 66 were studied through multinucleon transfer reactions by bombarding a "2"3"8U target with a 400 MeV "6"4Ni beam. Unambiguous identification of prompt #gamma# rays belonging to each nucleus was achieved using coincidence relationships with the ions detected in a high-acceptance magnetic spectrometer. The new data extend our knowledge of the level structure of Fe isotopes, which is discussed in terms of the systematics of the region and compared with large-scale shell-model calculations.

2007-09-01

66

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated ...

1999-11-01

67

Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

68

Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

69

Polarized neutron diffraction study of CePd{sub 3}  

Energy Technology Data Exchange (ETDEWEB)

We have performed polarized neutron diffraction measurements on the intermediate valence compound CePd{sub 3} using the D3 spectrometer at the ILL. The results show that at low temperatures, 1.7 K, as well as at 100 K, the field-induced magnetic amplitudes measured in a field of 4.6 T could be interpreted in terms of two contributions: a 4f-type contribution with a Ce{sup 3+} form factor, and an extra delocalized contribution (relatively narrow in q-extent). In particular, we find that the values of the 4f moment deduced from the extrapolation of the neutron data to Q=0 are systematically lower than the values deduced from bulk magnetization measurements performed on the same sample. This difference can be ascribed to a possible positive polarization of the conduction band which is similar at both temperatures.

2004-07-15

72

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased ...

2007-01-01

73

An overview on the study of quark gluon plasma with Alice dimuon spectrometer; Apercu sur l'etude du plasma de Quarks et de gluons a l'aide du spectrometre dimuons d'Alice  

Energy Technology Data Exchange (ETDEWEB)

The Alice experiment is one of the four main LHC (Large Hadron Collider) experiments. It is dedicated to the study of a new state of matter: the quark gluon plasma, where quarks and gluons are no longer confined within hadrons. In this document, the physics issues that led to the construction of Alice dimuon spectrometer, are described. Then, the research and development on the dimuon spectrometer is presented. The different absorbers are described and experimental tests used to determine their dimensions are presented. The dimuon trigger built using the RPC (Resistive Plate Chamber) streamer mode is then described along with the associated beam and cosmic tests and results. Finally, the tracking system is described in detail and more particularly all its electronics and the first station. The physics constraints on the expected performances of all these systems are clearly defined. (author)

2007-10-15

74

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

Energy Technology Data Exchange (ETDEWEB)

Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-15

75

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

International Nuclear Information System (INIS)

Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-01

76

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI ...

2009-05-15

77

Direct conversion of fusion energy into the electric one in the 'Dragon' magnetic confinement system  

International Nuclear Information System (INIS)

It is shown that recuperator in which the thermal energy of particles is transformed into electric oue under drift in crossed fields is naturally coupled with dragontype magnetic confinement system, so the recuperation process can be initiated in the dragon magnetic field. A number of questions occuring under analysis of recuperator-dragon system is considered, including the dynamics of particle transfer to the recuperator, the share of particles entering the recuperator, the effect of rotational transform and the recuperation efficiency.

79

Magnetic electronic lenses, quadrupole and octupole for microsystem electron beam techniques  

International Nuclear Information System (INIS)

The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered

2006-09-01

80

Surface analysis by Fourier-transform infrared (FTIR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.

1981-08-12

81

Rapid Sampling of Individual Organic Aerosol Species in Ambient Air with the Photoionization Aerosol Mass Spectrometer  

British Library Electronic Table of Contents (United Kingdom)

Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...

2008-01-01

82

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

83

Spectroscopic detection  

Energy Technology Data Exchange (ETDEWEB)

In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.

2003-01-01

84

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

85

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

86

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

87

An emulation and management software for MCA with 64 independent coded inputs  

International Nuclear Information System (INIS)

A Software for the Neutron Scattering time-of-flight Spectrometer with 64 independent coded inputs is preset. It performs data acquirement and management. The work platform of the software is the Windows 98 and programmed with Visual Basic 6.0. It supports 64 x 1024 channel analyzer computer system. The friendly interface, convenient operation and high reliability are advantages of the Software

2000-09-07

88

Theory of zwitterionic molecular-based organic magnets  

British Library Electronic Table of Contents (United Kingdom)

We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.

2011-01-01

89

Magnetic fluctuations in paramagnetic Mn{sub 0.81}Ni{sub 0.19}  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluctuations present in the paramagnetic Mn{sub 0.81}Ni{sub 0.19} system have been investigated by measuring inelastic magnetic neutron scattering from a single crystal at temperatures of 450, 585 and 700 K. Antiferromagnetic correlations are observed to be present at all the temperatures studied. The spectral width of the magnetic scattering has been observed to increase with temperature, while the spatial range of the magnetic correlations is seen to decrease as the temperature is raised. The wave-vector-dependent susceptibility is found to follow a Curie-Weiss law near the (1 0 0) position, in agreement with theoretical predictions.

2006-11-15

90

Kondo effect in the systems of magnetic trimers on a metal surface  

International Nuclear Information System (INIS)

Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)

2010-11-01

91

Instability of 4f and 3d magnetic moments under high pressure  

International Nuclear Information System (INIS)

The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).

92

Superconducting magnetic and inertial energy pulsed power systems  

International Nuclear Information System (INIS)

Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.

1975-07-15

93

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

94

Large specific absorption rates in the magnetic hyperthermia properties of metallic iron nanocubes  

CERN Document Server

We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large ...

2010-01-01

95

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

96

Magnetic phase diagrams of the TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} systems  

Energy Technology Data Exchange (ETDEWEB)

The a.c. susceptibility and high field magnetization of TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} compounds were investigated up to 140 kOe. The (T, x) magnetic phase diagrams were determined. For both systems, an increase in the Pd content causes a decrease in the Neel temperature and changes the magnetization curves. (orig.)

1995-12-01

97

Upgrade of X-ray Magnetic Diffraction Experimental System and Its Application to Ferromagnetic Material  

International Nuclear Information System (INIS)

We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. ...

2007-01-19

98

Comments on open-ended magnetic systems for fusion  

Energy Technology Data Exchange (ETDEWEB)

Differentiating characteristics of magnetic confinement systems having externally generated magnetic fields that are open'' are listed and discussed in the light of their several potential advantages for fusion power systems. It is pointed out that at this stage of fusion research high-Q'' (as deduced from long energy confinement times) is not necessarily the most relevant criterion by which to judge the potential of alternate fusion approaches for the economic generation of fusion power. An example is given of a hypothetical open-geometry fusion power system where low-Q operation is essential to meeting one of its main objectives (low neutron power flux).

1990-09-24

99

Spectroscopy of neutron-rich {sup 59-63}Mn isotopes  

Science.gov (United States)

The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a {sup 238}U target with a beam of {sup 70}Zn at an energy of E{sub lab}=460 MeV. Prompt {gamma} rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.

2008-08-15

100

Spectroscopy of neutron-rich "5"9"-"6"3Mn isotopes  

International Nuclear Information System (INIS)

The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a "2"3"8U target with a beam of "7"0Zn at an energy of E_l_a_b=460 MeV. Prompt #gamma# rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.

2008-08-01

101

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u {sup 86}Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss mesurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parameterization. The resulting prospects for reaching even more neutron-rich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1991-10-01

102

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u sup 86 Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1992-07-01

103

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u "8"6Kr beam  

International Nuclear Information System (INIS)

We have measured production cross-sections of the new neutron-rich isotopes "5"8Ti, "6"1V, "6"3Cr, "6"6Mn, "6"9Fe, "7"1Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u "8"6Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide "7"8Ni, are discussed. (orig.).

104

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

105

High-resolution NMR on /sup 29/Si nuclei in acidic zeolites  

Science.gov (United States)

The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.

1986-12-01

106

Experimental Study of Hypernuclei Electroproduction by High Precision Spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the ...

2009-12-01

107

Remote sensing of the atmosphere by resonance Raman LIDAR  

Energy Technology Data Exchange (ETDEWEB)

When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.

1994-12-01

108

Self-simulating motion of an ionized gas expelled by a magnetic piston  

Energy Technology Data Exchange (ETDEWEB)

The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.

1980-01-01

109

Methods of reducing magnetic field near the transmission lines  

International Nuclear Information System (INIS)

Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.

2003-01-01

110

Invariant correlation functions, superconvergence sum rules, and electric-magnetic duality  

Energy Technology Data Exchange (ETDEWEB)

The gauge-invariant correlation function for the Yang-Mills field strengths is shown to admit a symmetric decomposition into electric and magnetic components. The spectral weights are seen to obey a sum rule of the superconvergence type, owing to asymptotic freedom. The close relation between the dielectric function, electric-magnetic duality, and the algebra of generalized Chern-Simons charges is illustrated for the linearized Yang-Mills-Higgs system.

1988-01-01

111

Kondo effect and impurity-impurity interaction in (La, Ce)B_6 alloys  

International Nuclear Information System (INIS)

Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY ...

1978-01-01

112

Development of magnetic separation system of magnetoliposomes  

Energy Technology Data Exchange (ETDEWEB)

The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was ...

2009-10-15

113

Anti-cancer drug loaded iron-gold core-shell nanoparticles (Fe@Au) for magnetic drug targeting.  

Science.gov (United States)

Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus simulating the human ...

2010-09-01

114

Algebraic analysis of the electromagnetic wave interaction with the two-level system with two-fold degenerated states  

Energy Technology Data Exchange (ETDEWEB)

Algebraic properties of the analytical model, describing electro-magnetic weak interaction with the two-level system with two-fold degenerate state are considered. The expressions for the coherent states and Green function of the system are obtained.

1989-04-20

115

Injection and extraction magnets: septa  

CERN Document Server

An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.

2010-01-01

116

REPORTABLE ITEMS - NASA Technical Report Server (NTRS)  

Science.gov (United States)

A shipbuilder is using an electro-magnetic forming system (on loan from NASA) in a development program. " A modification in the design of a metal bending ...

117

EMFs: cutting through the controversy.  

UK PubMed Central (United Kingdom)

SOME SCIENTISTS ALLEGE that exposure to electric and magnetic fields generated by electric power delivery systems is responsible for certain cancers (particularly among children), reproductive dysfunction,...Full Text Available

1996-05-01

118

A Magnetic Suspension and Excitation System for Spin Vibration ...  

Science.gov (United States)

High Cycle Fatigue Initiative Workshop -Active Vibration. Control/Engine. Health Monitoring Session December 10,. 1996. The presentation was titled "Active ...

119

Bacterial cultivation in high magnetic fields by 7-tesla superconducting magnet; 7T chodendo magnet ni yori hasseishita kojiba ni okeru biseibutsu no baiyo  

Energy Technology Data Exchange (ETDEWEB)

Although a large number of studies on effects of magnetic fields on living organisms was reported, no definite results were obtained in many cases because the related conditions are non-uniform and uncertain, such that the uniform magnetic space is smaller than test samples, and temperature control is insufficient. Therefore, the present study developed a microorganism cultivation system that is applied with a 7-T superconducting magnet. This system has the following features: it generates homogeneous magnetic fields of 0.5 to 7 T {plus_minus} 0.5% in the space with a diameter of 100 mm and a length of 200 mm in a normal temperature bore (with a diameter of 160 mm); it can cultivate microorganisms aerobically at temperatures of 10 to 70{degree}C {plus_minus} 0.1{degree}C; it can perform the cultivation simultaneously with a control cultivation in a small ...

1994-12-20

120

Temperature dependence of a twofold magnetic behaviour of a nanoscopic metal/silicon hybrid system - a comparison between Ni/Si and Co/Si  

Energy Technology Data Exchange (ETDEWEB)

The investigated hybrid nanocomposite consists of a porous silicon template with electrochemically embedded Ni or Co nanostructures and offers magnetic characteristics which can be tailored by the electrochemical process parameters during fabrication. A twofold magnetic behaviour can be observed, a first one due to the spinmagnetism at magnetic fields below the saturation magnetization of the deposited metals and a second non-saturating term at higher fields (>1 T up to 7 T) above the saturation magnetization. In case of Ni deposited within the pores this non-saturating term shows a paramagnetic characteristic and follows exactly the Curie-Weiss law, whereas for Co/porous silicon samples the temperature dependent magnetization shows some deviations from the Curie Weiss law. In this high field region a difference in the temperature dependence between Ni ...

2009-10-15

121

Design of modular coils for a quasi-axisymmetric stellarator with a flexible control of the magnetic field configuration  

Energy Technology Data Exchange (ETDEWEB)

A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a flexibility of the magnetic field configuration is realized. For the case that the ...

2002-08-01

122

The Multipoles Factory An Element of the LHC Control  

CERN Document Server

The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we ...

2002-01-01

123

DFT study of structure?properties correlations in [MnTPP][TCNE] quasi-one-dimensional molecular magnets  

British Library Electronic Table of Contents (United Kingdom)

We report the first band structure calculations of the quasi-one-dimensional [MnTPP][TCNE] compounds (TPP?=?meso-tetraphenylporphyrinato, TCNE?=?tetracyanoethylene), based on Density Functional Theory (DFT) methods, in order to interpret the magnetic ordering in these prototypic systems. We compare and contrast the results of broken-symmetry DFT calculations for extended systems, with periodic boundary conditions, and for finite systems, magnetic dimers modeling the actual molecular magnets. By varying systematically the main angles, we are able to determine the geometry dependence of the exchange interaction. Structure?properties correlations in these charge-transfer salts reveal the determinant role of the Mn-(N?C)TCNE bond angle on the strength of the ferrimagnetic coupling between the ...

2011-01-01

124

Towards a realistic model of Fe-Cu-Fe spin valve systems using tight-binding methods  

Energy Technology Data Exchange (ETDEWEB)

Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.

1996-12-31

125

Research on ambient temperature passive magnetic bearings at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

Research performed at the Lawrence Livermore National Laboratory on the equilibrium and stability of a new class of ambient-temperature passive bearing systems is described. The basic concepts involved are: (1) Stability of the rotating system is only achieved in the rotating state. That is, disengaging mechanical systems are used to insure stable levitation at rest (when Earnshaw`s theorem applies). (2) Stable levitation by passive magnetic elements can be achieved if the vector sum of the force derivatives of the several elements of the system is net negative (i.e. restoring) for axial, transverse, and tilt-type perturbations from equilibrium. To satisfy the requirements of (2) using only permanent magnet elements we have employed periodic ``Halbach arrays.`` These interact with passive inductive loaded circuits and act as stabilizers, with the primary forces ...

1997-04-01

126

A modular and extensible data acquisition and control system for testing superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into operation. This ...

2001-07-20

127

Noncollinear magnetism in surfaces and interfaces of transition metals  

Energy Technology Data Exchange (ETDEWEB)

Noncollinear (NC) magnetism is common in nature, especially when there exist geometrical frustration and chemical imparity in the system. In this work we studied the NC magnetism and the response to external magnetic fields in surfaces and interfaces of transition metals by using an semi-empirical tight-binding (TB) method that parameterized to the ab initio TB-LMTO calculations. We implemented this method to study two systems. The first one is the system of 6 Mn monolayers on Fe(001) substrate. Due to the complex structure and magnetic properties of Mn, we found 23 collinear magnetic configurations but only one NC configuration. The collinear ground state has a layered antiferromagnetic (AFM) coupling which agrees with previous experiments and calculations. In the NC configuration the local AFM coupling in the Mn layers ...

2009-09-15

128

The addition of trim coils to the Tandem Mirror Experiment magnet system to improve the magnetic field mapping  

International Nuclear Information System (INIS)

The mapping of the magnetic flux bundle from the center cell to the Plasma Potential Control plates (PPC) on the end fan of the Tandem Mirror Experiment Upgrade (TMX-U), was improved by the addition of trim coils (12,000 amp-turns) on each side of each end fan next to the pump beam magnetic shields. The coils' axes are oriented perpendicular to the machine centerline. These coils made the necessary corrections to the field-line mapping, while keeping the field in the nearby pump beam magnetic shield below the saturation threshold. This paper briefly describes the problem, discusses the design as it evolved, and presents the results of the field testing. A brief description of the improvement in the machine performance is also included.

129

Application of GIS for the evaluation of human exposure to magnetic field in the vicinity of power lines  

Energy Technology Data Exchange (ETDEWEB)

Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.

1998-10-01

130

Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?  

UK PubMed Central (United Kingdom)

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available

2009-03-01

131

Superconducting magnetic system with the controllable inductance of a winding  

International Nuclear Information System (INIS)

The experimental superconducting magnetic system of 0.5 MJ energy storage is described. The step variation of the winding inductance provides a control by the discharge current at the energy output on a high-ohmic load. The voltage on a load is 45 kV at the current 1100 A under the controllable discharge conditions. The energy transfer coefficient constitutes 0,76 under the maximum-to-minimal current ratio equal to 1.3. 7 refs., 3 figs., 2 tabs.

132

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

133

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that ...

134

Ultrastructural Evidence of Dermal Gadolinium Deposits in a Patient with Nephrogenic Systemic Fibrosis and End-Stage Renal Disease  

UK PubMed Central (United Kingdom)

Background and objectives: The pathogenesis of acquired nephrogenic systemic fibrosis recently described for patients with renal insufficiency and a history of exposition to gadolinium-based magnetic...Full Text Available

2008-07-01

135

A combination of transposable elements and magnetic cell sorting provides a very efficient transgenesis system for chicken primary erythroid progenitors  

UK PubMed Central (United Kingdom)

BackgroundStable transgenesis is an undeniable key to understanding any genetic system. Retrovirus-based insertional strategies, which feature several technical challenges when they...Full Text Available

136

The sup(187m)Ir isomer state and its decay scheme  

International Nuclear Information System (INIS)

... beta spectrometers comparative evaluations data decay electrons

137

The conversion spectrum of Sr"8"8  

International Nuclear Information System (INIS)

... beta spectrometers decay energy-level transitions k conversion l conversion

142

Development of magnet power supply for J-PARC 50-GEV synchrotron  

International Nuclear Information System (INIS)

A new magnet power supply system for J-PARC 50GeV Synchrotron is proposed as solutions both in the power capacity and in the precision at the same time. The developed 10MW class magnet power supply consists of the advanced self-commutated current-source type converter (ACSC) using the new device IEGT rated at 4500V-2100A and the ''hybrid filter'' including the variable impedance filter with the equivalent 16 kHz switching. With 1/16 scale-model system using a prototype bending magnet, the experimental results showed the current ripple less than 1 x 10"-"6 and the tracking error less than #+-#0.5 x 10"-"4. (author)

2004-08-04

143

Development of high-field STM for 18 T cryocooled superconducting magnet  

International Nuclear Information System (INIS)

To study the nanoscale electronic order in strongly correlated electron systems and vortex states in high-Tc superconductors in high magnetic fields, we have developed scanning tunneling microscopy (STM) for the 18 T cryocooled superconducting magnet (18T-CSM). The test results of the STM operation in the 18T-CSM at room temperature indicate that our STM has a good atomic resolution up to 18 T when we use the nonmagnetic vibration-isolation table which reduce the vibration noise from the cryocoolers of the 18T-CSM. In this paper, we report on the design of the high-field STM system for large-scale magnets and its performance.

2009-02-01

144

Diagnostics aid for mass spectrometer trouble-shooting  

International Nuclear Information System (INIS)

The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic ...

145

Magnetic microstructure of candidates for epitaxial dual Heusler magnetic tunnel junctions  

Energy Technology Data Exchange (ETDEWEB)

Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.

2009-05-15

146

Study of Japanese electrodynamic-suspension maglev systems  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of a study of the Japanese MLU magnetic-levitation (maglev) system. The development of the MLU system is reviewed, and the dynamic circuit model then is introduced and applied to the figure-eight-shaped null-flux coil suspension system. Three different types of figure-eight-shaped null-flux suspension systems are discussed in detail: (1) the figure-eight-shaped null-flux coil suspension system without cross-connection; (2) the combined suspension and guidance system; and (3) the combined propulsion, levitation, and guidance system. The electrodynamic-suspension maglev systems developed in Japan seem to be very promising and could result in a commercial application in the near future.

1994-04-01

147

Research and development project for flywheel energy storage system using high-temperature superconducting magnetic bearing  

Energy Technology Data Exchange (ETDEWEB)

Recent progress in yttrium-based oxide high-temperature superconductors has enabled the production of a large diameter bulk with a strong flux-pinning force. A combination of this superconductor and a permanent magnet makes it feasible to fabricate a noncontact, non-controlled superconducting magnetic bearing with a very small rotational loss, applicable to a flywheel energy storage system. A conceptual design of an 8 MWh flywheel energy storage system using the new bearing has been developed, based on measured data on a miniature bearing model, which proved to be potentially capable of achieving a high energy storage efficiency of 84 pc. A 100 W h-class experimental system was then built, which attained a high revolution rate of 17000 rpm, with a rotational loss of about 0.6 W. (authors). 2 refs., 7 figs., 3 tabs.

1995-12-31

148

LHC Magnet Tests Operational Techniques and Empowerment for Successful Completion  

CERN Document Server

The LHC magnet tests operation team developed various innovative techniques, particularly since early 2004, to complete the superconductor magnet tests by Feb. 2007. Overall and cryogenic priority handling, rapid on-bench thermal cycling, rule-based goodness evaluation on round-the-clock basis, multiple, mashed web systems are some of these techniques applied with rigour for successful tests completion in time. This paper highlights these operation empowerment tools which had a pivotal role for success. A priority handling method was put in place to enable maximum throughput from twelve test benches, having many different constraints. For the cryogenics infrastructure, it implied judicious allocation of limited resources to the benches. Rapid On-Bench Thermal Cycle was a key strategy to accelerate magnets tests throughput, saving time and simplifying logistics. First level magnet ...

2007-01-01

149

Problems and solutions of the IFSMTF power and switch system  

Energy Technology Data Exchange (ETDEWEB)

Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.

1985-01-01

150

Magneto thermal convection in a compressible couple-stress fluid  

Energy Technology Data Exchange (ETDEWEB)

The problem of thermal instability of compressible, electrically conducting couple-stress fluids in the presence of a uniform magnetic field is considered. Following the linearized stability theory and normal mode analysis, the dispersion relation is obtained. For stationary convection, the compressibility, couple-stress, and magnetic field postpone the onset of convection. Graphs have been plotted by giving numerical values of the parameters to depict the stability characteristics. The principle of exchange of stabilities is found to be satisfied. The magnetic field introduces oscillatory modes in the system that were non-existent in its absence. The case of overstability is also studied wherein a sufficient condition for the non-existence of overstability is obtained. (orig.)

2010-03-15

151

Finite element stress analysis of the CMS magnet coil  

CERN Document Server

The Compact Muon Solenoid (CMS) is one of the experiments which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN. The design field of the CMS magnet is 4 T, the magnetic length is 12.38 m and the aperture is 6.36 m. This is achieved with a 4 layer-5 module superconducting Al-stabilized coil energised at a nominal current of 20 kA. The finite element analysis (FEA) carried out is axisymmetric elasto-plastic. FEA has also been carried out on the suspension system and on the conductor. (8 refs).

2000-01-01

152

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of ...

1997-05-01

153

Joule-Thomson cryogenic cooler with extremely high thermal stability  

Science.gov (United States)

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

1991-06-01

154

Cavity ringdown spectroscopy with a continuous-wave laser: calculation of coupling efficiency and a new spectrometer design.  

Science.gov (United States)

For the efficient operation of a cavity ringdown spectroscopy (CRDS) system utilized with a continuous-wave (cw) laser, we numerically analyze the coupling efficiency of a cw laser to a ringdown cavity in terms of changes in the scanning rate, the laser linewidth, and the mirror reflectivity. We also demonstrate a new simple design for a CRDS system that can produce a CRDS signal with only a piezoelectric transducer (PZT), without the acousto-optic modulator that is usually adopted to switch off the cw laser beam that enters the cavity. Furthermore, we investigate the feasibility of the cw CRDS technique with a fast-scanning PZT by recording a CRDS spectrum of acetylene overtones. The detection sensitivity that corresponds to the noise-equivalent absorption is found to be approximately 3 x 10(-9)/cm. PMID:18305817

1999-03-20

156

COLLAPSE AND FRAGMENTATION OF MOLECULAR CLOUD CORES. X. MAGNETIC BRAKING OF PROLATE AND OBLATE CORES  

International Nuclear Information System (INIS)

The collapse and fragmentation of initially prolate and oblate, magnetic molecular clouds is calculated in three dimensions with a gravitational, radiative hydrodynamics code. The code includes magnetic field effects in an approximate manner: magnetic pressure, tension, braking, and ambipolar diffusion are all modeled. The parameters varied for both the initially prolate and oblate clouds are the initial degree of central concentration of the radial density profile, the initial angular velocity, and the efficiency of magnetic braking (represented by a factor f _m_b = 10"-"4 or 10"-"3). The oblate cores all collapse to form rings that might be susceptible to fragmentation into multiple systems. The outcome of the collapse of the prolate cores depends strongly on the initial density profile. Prolate cores with central densities 20 times higher than their boundary densities collapse ...

2009-06-01

157

Entanglement of systems of dipolar coupled nuclear spins at the adiabatic demagnetization  

CERN Document Server

We consider the adiabatic demagnetization in the rotating reference frame (ADRF) of a system of dipolar coupled nuclear spins $s=1/2$ in the external magnetic field. The demagnetization starts with the offset of the external magnetic field (in frequency units) from the Larmor frequency being several times greater than the local dipolar field. For different subsystem sizes, we have found from numerical simulations the temperatures at which subsystems of a one-dimensional nine-spin chain and a plane nine-spin cluster become entangled. These temperatures are of the order of microkelvins and are almost independent of the subsystem size. There is a weak dependence of the temperature on the space dimension of the system.

2008-01-01

158

Magnetic excitations in R_2PdSi_3 studied by inelastic neutron scattering  

International Nuclear Information System (INIS)

R_2PdSi_3 compounds have been found to exhibit rich magnetic phenomena arising from the interplay between RKKY interaction, crystal electric field effects and geometric frustration due to the derived hexagonal AlB_2 structure. The observed crystallographic superstructure further complicates the CEF level scheme. Inelastic neutron scattering measurements on single crystals of Tm_2PdSi_3 and Er_2PdSi_3 have been performed at the cold triple axis spectrometer PANDA in FRM-II. Both compounds order antiferromagnetically at T_N=7 K and 2.1 K respectively; Er_2PdSi_3 undergoes a second phase transition at T_2=2 K. Several low lying CEF excitations (below 10 meV) were observed. The intensity of the lowest excitation show strong directional dependence (in HK0 plane for Er_2PdSi_3 and in HHL plane for Tm_2PdSi_3), from which the details of the transitional matrix could be deduced. Measurements in magnetic fields up to 13 T show ...

2009-03-22

159

Measurement of the Electron Affinities of Indium and Thallium  

Energy Technology Data Exchange (ETDEWEB)

The electron affinities of indium and thallium were measured in separate experiments using the laser-photodetachment electron spectroscopy technique. The measurements were performed at the University of Nevada, Reno. Negative ion beams of both indium and thallium were extracted from a cesium-sputter negative ion source, and mass analyzed using a 90{sup o} bending magnet. The negative ion beam of interest was then crossed at 90{sup o} with a photon beam from a cw 25-Watt Ar{sup +} laser. The resulting photoelectrons were energy analyzed with a 160{sup o} spherical-sector spectrometer. The electron affinity of In({sup 2}P{sub 1/2}) was determined to be 0.404 {+-} 0.009 eV and the electron affinity of thallium was determined to be 0.377 {+-} 0.013 eV. The fine-structure splittings in the ground states of the negative ions were also determined. The experimental measurements will be compared to several recent theoretical predictions.

1999-03-20

160

Interaction of 8 MeV /sup 12/C with /sup 88/Sr; neutron transfer, inelastic scattering and spin alignment of the 2/sup +/ state of /sup 12/C  

Energy Technology Data Exchange (ETDEWEB)

Using a Q3D magnetic spectrometer the elastic and inelastic scattering of /sup 12/C on /sup 88/Sr and the neutron pick-up (/sup 12/C, /sup 13/C) has been studied. The spin alignment of the inelastically excited 2/sup +/ state of /sup 12/C (4.43 MeV) has been deduced from the line shapes broadened by the ..gamma..-decay in flight. Thus for each m-substate a full angular distribution was obtained. The m = 1 substate shows a shifted interference minimum, which is explained by the different strength of the Coulomb and nuclear amplitudes in the m-substates. The analysis of the data on elastic scattering, inelastic scattering, alignment and the neutron transfer can be described consistently with one choice of the optical model parameters.

1982-04-01

161

A new measurement of the antiproton-to-proton flux ratio up to 100 GeV in the cosmic radiation  

CERN Document Server

A new measurement of the cosmic ray antiproton-to-proton flux ratio between 1 and 100 GeV is presented. The results were obtained with the PAMELA experiment, which was launched into low-earth orbit on-board the Resurs-DK1 satellite on June 15th 2006. PAMELA is equipped with a silicon-microstrip magnetic spectrometer and a silicon-tungsten imaging calorimeter and has been collecting data since July 2006. During 500 days of data collection a total of about 1000 antiprotons have been identified, including 100 above an energy of 20 GeV. The high-energy results are a ten-fold improvement in statistics with respect to all previously published data. The antiproton-to-proton flux ratio increases smoothly with energy up to about 10 GeV, in agreement with previous experiments, and then levels off. The data follow the trend expected from secondary production calculations and significantly constrain contributions from exotic sources, e.g. dark matter ...

2008-01-01

162

System and method for non-destructive evaluation of surface characteristics of a magnetic material  

Energy Technology Data Exchange (ETDEWEB)

A system and a related method for non-destructive evaluation of the surface characteristics of a magnetic material. The sample is excited by an alternating magnetic field. The field frequency, amplitude and offset are controlled according to a predetermined protocol. The Barkhausen response of the sample is detected for the various fields and offsets and is analyzed. The system produces information relating to the frequency content, the amplitude content, the average or RMS energy content, as well as count rate information, for each of the Barkhausen responses at each of the excitation levels applied during the protocol. That information provides a contiguous body of data, heretofore unavailable, which can be analyzed to deduce information about the surface characteristics of the material at various depths below the surface.

1994-05-17

163

The influence of asymmetry on a magnetized proto-neutron star  

Energy Technology Data Exchange (ETDEWEB)

Using the Relativistic Mean Field Theory (RMF) it is shown that different proton fraction which is directly connected with the neutron excess and with the asymmetry of the system affects proto-neutron stars parameters and changes their composition. The obtained form of the equation of state allows to construct the mass-radius relations and shows that the increasing asymmetry creates more compact stars. The inclusion of {delta} meson together with nonlinear vector meson interaction terms and magnetic field make this effect even stronger.

2003-03-24

164

Magnetoresistance of Two-Dimensional Tight-Binding Electrons in a Weak Magnetic Field  

International Nuclear Information System (INIS)

We study the Anderson model on a two-dimensional square lattice with an applied weak magnetic field B which causes the hopping matrix elements to have Peierls phase factors. The recursion method is applied and B dependent conductivity ?(B) is calculated from the Kubo formula for different system sizes and degree of disorder W . For large W there is no systematic change of ?(B) with B, it shows a fluctuating behavior.

2008-08-25

165

Magnetic behavior in the U/sub 1-x/Th/sub x/Cu_2Si_2 system  

International Nuclear Information System (INIS)

The compound UC_2Si_2 has been found to be ferromagnetic at low temperatures with a Curie temperature of 101"0K. The magnetization follows a Curie-Weiss law in the paramagnetic region with an effective magneton number of 2.12 Bohr magnetons per uranium atom. Partial substitution of Th atoms for the U atoms results in an expansion of the lattice, a rapid drop in the Curie temperature, and a sizable increase in the coercive field.

1986-06-23

166

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

167

MAGNETIC ELECTRON MICROSCOPE UEMB-100  

Science.gov (United States)

A new magnetic electron microscope, UEMB-100, was designed with an increased electron-optical parameter. The electron-optical system consists of an electron canon (the high voltage is supplied by armored lead) and condensed, objective, intermediate, and projection lenses. In contrast to other native apparatuses, the microscope has a high resolving property (up to 20A) snnd great universality. (tr-auth)

1958-07-01

168

Influence of relaxation phenomena in liquid phase on magnetic anisotropy of metallic glasses  

International Nuclear Information System (INIS)

It if first shown, that the effective field of uniaxial magnetic anisotropy of Fe-Cr-P-C and Fe-Ni-B-Si system amorphous alloys is reduced with an increase of the source melt isothermal exposure time. The behaviour noted is conditioned by microcoherence and relaxation processes in the nonequilibrium liquid phase after crystal-liquid phase transition.

1996-12-01

169

Fatty acid distribution in systems modeling the normal and diabetic human circulation. A 13C nuclear magnetic resonance study.  

UK PubMed Central (United Kingdom)

A nonperturbing 13C nuclear magnetic resonance (NMR) method was used to monitor the equilibrium distribution of carboxyl 13C-enriched fatty acids (FA) between distinct binding sites on human serum albumin,...Full Text Available

1991-04-01

170

Depth profile of uncompensated spins in an exchange bias system  

Energy Technology Data Exchange (ETDEWEB)

We have used the unique spatial sensitivity of polarized neutron and soft x-ray beams in reflection geometry to measure the depth dependence of magnetization across the interface between a ferromagnet and antiferromagnet. The new uncompensated magnetization near the interface responds to applied field, while the uncompensated spins in the antiferromagnetic bulk are pinned, thus providing a means to establish exchange bias.

2005-05-17

171

A magnetically insulated negative ion source for neutral beam heating  

Energy Technology Data Exchange (ETDEWEB)

A new, magnetically insulated negative ion source has recently been discovered which can produce pulsed negative ion beams (H/sup -/, Li/sup -/, and C/sup -/) with intensities of 100-300 A/cm/sup 2/ at 1-4 MeV. This source may provide the basis for a high energy neutral beam system for heating large tokamaks.

1983-08-01

172

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ...

173

Spin-polarized Auger-electron diffraction study of the magnetic poisoning of Fe(001) by sulfur  

International Nuclear Information System (INIS)

Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.

174

Magnetic properties of B and AB-spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Ni, Mg) materials  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of diluted spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) systems have been studied by mean field theory, probability law and high-temperature series expansions method in the range 0 {<=} x {<=} 1. The exchange interactions are calculated by the first and second theory, respectively. The magnetic phase diagrams of Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) are calculated by the high-temperature series expansions, combined with the Pade approximants method. The critical exponent associated with the magnetic susceptibility ({gamma}) is deduced.

2010-08-06

175

Magnetic and electronic properties of Mn{sub 4}Si{sub 7}  

Energy Technology Data Exchange (ETDEWEB)

We present a systematic study of the magnetization, Hall effect and specific heat on single crystals of Mn{sub 4}Si{sub 7}. Curie-Weiss law is observed above 43 K. At low-temperature moments order in an anisotropic helical state and are aligned above 1 T. We observe an anomalous Hall effect in both {rho}{sub H} vs. B and in R{sub H} vs. T curves and a field dependence of the low T specific heat due to spin fluctuations. The magnetic moments (p{sub eff} and p{sub sat}) are the lowest reported for similar itinerant magnetic systems, this suggests that Mn{sub 4}Si{sub 7} is a good candidate to observe critical quantum fluctuations expected for a marginal Fermi liquid.

2004-05-01

176

Kinematics and flow characteristics of a magnetic actuated multi-cilia configuration  

British Library Electronic Table of Contents (United Kingdom)

The current paper continues the analysis of a completely novel method of fluid manipulation technology in micro-fluidics systems, inspired by nature, namely by the mechanisms found in ciliates. More information on this subject can be found at http://www.hitech-projects.com/euprojects/artic/. In order to simulate the drag forces acting on an array of artificial cilia, we have developed a computer code that is based on fundamental solutions of Stokes flow in a semi-infinite domain. The actuation mechanism consists of a bi-directional rotating excitation magnetic field. The magnetization induced by the magnetic field was calculated in a separate routine based on the Integral Nonlinear Equations Approach with 1D discretization of wire (cilium). Time averaged x-coordinate mass flow rates, strea...

2011-01-01

177

Gamma irradiation induced damage creation on the cation distribution, structural and magnetic properties in Ni-Zn ferrite  

International Nuclear Information System (INIS)

Ferrite of system, namely Ni_1_-_xZn_xFe_2O_4 with x = (0.0, 0.2, 0.4, 0.6, 0.8, 1.0), have been prepared by solid state reaction to investigate the effect of gamma rays irradiations using Co"6"0 source on the cation distribution, structural and magnetic properties. The unirradiated and irradiated samples were then subjected to characterization techniques such as X-ray diffraction, magnetization and AC susceptibility. The results of these characterizations are found to be different for irradiated from that of the pristine sample. The modifications in respect of irradiated samples are explained in terms of the ion-induced disorder. The important result of #gamma#-irradiation on the cation distribution, structural and magnetic properties is the change of ratio Fe"2"+/Fe"3"+. Possible reasons on the results are proposed.

2010-09-01

178

A classical model for the magnetic field-induced Wigner crystallization in quantum dots  

Energy Technology Data Exchange (ETDEWEB)

A classical model is presented for magnetic field-induced Wigner crystallization in electron systems confined within two-dimensional quantum dots. In contrast to other classical models, this one does not treat an electron as a point charge; the electron density is assumed to take a Gaussian form corresponding to the lowest Landau level. Using a Monte Carlo method we have determined the equilibrium configurations as functions of the magnetic field. We have found a classical counterpart of the quantum maximum density droplet (MDD) and studied the breakdown of the MDD into a Wigner molecule as well as the transformations of the Wigner molecule shape induced by the external magnetic field. The phase diagram for the classical Wigner molecules has been presented and its qualitative agreement with previous quantum mechanical calculations has been shown.

2004-03-03

179

Ferroelectric and magnetic properties of Ho{sub 2}CuTiO{sub 6} double perovskite  

Energy Technology Data Exchange (ETDEWEB)

Ho{sub 2}CuTiO{sub 6} double pervoskite is synthesized by solid state reaction method and the phase formation was confirmed by X-ray diffraction. Ho{sub 2}CuTiO{sub 6} crystallizes in space group P63 cm and are isostructural in AMnO{sub 3} structure. We have investigated the effect of the presence of a magnetic ion (Ho{sup 3+}{approx}10.4{mu}{sub B}) in Ho{sub 2}CuTiO{sub 6}, on the magnetic properties, compared to that of an isostructural double perovskite containing Y-ion (non-magnetic), i.e., Y{sub 2}CuTiO{sub 6}. Magnetization measurements on Ho{sub 2}CuTiO{sub 6} showed paramagnetic moment of 0.026{mu}{sub B}/Ho at room temperature in an applied field of 7 T although no saturation is observed at room temperature, whereas, at 5 K, the paramagnetic moment was 0.3{mu}{sub B}/Ho in the same field. Since this compound is non-centrosymmetric, it is of interest to look into the possibility of realizing ...

2006-08-15

180

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for ...

1997-05-01

181

Summary of the report of the Senior Committee on Environmental, Safety, and Economic Aspects of Magnetic Fusion Energy  

Energy Technology Data Exchange (ETDEWEB)

The Senior Committee on Environmental, Safety, and Economic Aspects of Magnetic Fusion Energy (ESECOM) has assessed magnetic fusion energy's prospects for providing energy with economic, environmental, and safety characteristics that would be attractive compared with other energy sources (mainly fission) available in the year 2015 and beyond. ESECOM gives particular attention to the interaction of environmental, safety, and economic characteristics of a variety of magnetic fusion reactors, and compares them with a variety of fission cases. Eight fusion cases, two fusion-fission hybrid cases, and four fission cases are examined, using consistent economic and safety models. These models permit exploration of the environmental, safety, and economic potential of fusion concepts using a wide range of possible materials choices, power densities, power conversion schemes, and fuel cycles. The ESECOM analysis indicates ...

1987-09-10

182

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

183

Neurosarcoidosis--demonstration of meningeal disease by gadolinium enhanced magnetic resonance imaging.  

UK PubMed Central (United Kingdom)

Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available

1991-06-01

184

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.

1984-03-01

185

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

International Nuclear Information System (INIS)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).

186

Study of the reaction {sup 22}Ne(131 MeV) + {sup 208}Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up  

Energy Technology Data Exchange (ETDEWEB)

An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.

2005-07-01

187

A novel electrochemical alkylation of aniline with methanol over Zn/Cu salts modified kaolin  

British Library Electronic Table of Contents (United Kingdom)

A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...

2008-01-01

188

Phase separation, transport and magnetic properties of La2/3A1/3Mn1-xCoxO3, A=Ca, Sr (0.5x1)  

British Library Electronic Table of Contents (United Kingdom)

We present the low-temperature physical properties of the polycrystalline perovskite systems La2/3A1/3Mn1-xCoxO3, A=Ca, Sr (0.5x1) including electrical resistance, magnetization, ac and dc susceptibilities. The experimental data suggest the presence of correlated ferromagnetic clusters embedded in some non-ferromagnetic matrix. The systems show semiconducting behavior and negative magnetoresistance.

2008-01-01

189

Ignition system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an ignition system of an internal combustion engine which consists of: a permanent magnet supported by a rotary member of the engine adapted to rotate in synchronism with a rotary shaft of the engine; a generating coil for generating an electromotive force to produce an electric current as the permanent magnet acts on the generating coil during the rotation of the rotary member; an ignition capacitor charged by the electric current generated by the generating coil; a thyristor caused to turn on by a counter electromotive force generated by the generating coil to thereby cause the ignition capacitor to begin to discharge; and an ignition coil generating a high voltage as the ignition capacitor begins to discharge, to cause a spark discharge to take place in an ignition plug of the internal combustion engine.

1986-09-16

190

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, the authors are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. They are actively developing improved DC iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. They are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. They are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1988-03-01

191

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, we are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. We are actively developing improved dc iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. We are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. We are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1987-01-01

192

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

193

The impact of solar flares and magnetic storms on humans  

International Nuclear Information System (INIS)

Three classes of solar emanations, namely, photon radiation from solar flares, solar energetic particles, and inhomogeneities in the solar wind that drive magnetic storms, are examined, and their effects on humans and technological systems are discussed. Solar flares may disrupt radio communications in the HF and VLF ranges. Energetic particles pose a special hazard at low-earth orbit and above, where they can penetrate barriers such as spacesuits and aluminum and destroy cells and solid state electronics. Energetic solar particles also influence terrestrial radio waves propagating through polar regions. Magnetic storms may disturb the operation of navigation instruments, power lines and pipelines, and satellites; they give rise to ionospheric storms which affect radio communication at all latitudes. There is also a growing body of evidence that changes in the geomagnetic field affect biological ...

194

Field-induced valence transition of Eu(Pd_1_-_xPt_x)_2Si_2  

International Nuclear Information System (INIS)

The magnetic susceptibility and high-field magnetization have been measured for the intermediate valence system Eu(Pd_1_-_xPt_x)_2Si_2 with 0#<=#x#<=#0.15. A first-order valence transition is observed for all the compounds under high field of 100 T at low temperatures. This valence transition is of first order accompanied with a large hysteresis, which is in contrast to a continuous valence change against temperature. Based on the interconfigurational fluctuation (ICF) model, the temperature- and field-induced valence transitions are discussed. It is found that a first-order valence transition can be induced by magnetic field, even if the system shows a continuous valence transition against temperature. Metamagnetic behavior at finite temperatures is also understood qualitatively by the ICF model. copyright 1997 The American Physical Society.

195

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

196

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

197

USSR Report, Electronics and Electrical Engineering.  

Science.gov (United States)

... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...

1985-04-30

198

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

199

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

201

Liquid metal cooled fast breeder reactor comprising electromagnetic braking systems of the coolant flow  

International Nuclear Information System (INIS)

The liquid-metal-cooled fast breeder reactor presented includes a fuel assembly made up of several long sub-assemblies rising side by side. Each of the sub-assemblies of an external area of the fuel assembly comprises an electromagnetic braking system for regulating the flow of coolant in the sub-assembly, the magnetic fields of the braking systems being temperature sensitive.

202

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system  

International Nuclear Information System (INIS)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).

203

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

Energy Technology Data Exchange (ETDEWEB)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a ...

1995-03-01

204

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

International Nuclear Information System (INIS)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a ...

205

Disturbance Rejection Control of an Electromagnetic Bearing Spindle  

Energy Technology Data Exchange (ETDEWEB)

The force exerted on the rotor by an active magnetic bearing (AMB) is determined by the current flow in the magnet coils. This force can be controlled very precisely, making magnetic bearings a potential benefit for grinding, where cutting forces act as external disturbances on the shaft, resulting in degraded part finish. It is possible to achieve precise shaft positioning, reduce vibration of the shaft caused by external disturbances, and even damp out resonant modes. Adaptive control is an appealing approach for these systems because the controller can tune itself to account for an unknown periodic disturbance, such as cutting or grinding forces, injected into the system. In this paper the authors show how one adaptive control algorithm can be applied to an AMB system with a periodic disturbance applied to the rotor. An adaptive algorithm was developed and ...

2000-08-31

206

FOCUS: time-of-flight spectrometer for cold neutrons at SINQ  

Energy Technology Data Exchange (ETDEWEB)

The physical layout of the Time-Of-Flight spectrometer at the new spallation source SINQ is presented. The concept shows up a hybrid-TOF combining a Fermi-chopper with a crystal monochromator. The demand of a versatile and flexible instrument for several applications is taken into account by the option of switching from time-focusing to monochromatic focusing mode such that the spectrometer can be optimised for both quasielastic and inelastic scattering applications. (author) 5 figs., 2 tabs., 16 refs.

1996-11-01

207

A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations  

Science.gov (United States)

A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.

2004-12-01

208

Starting characteristics of direct current motors powered by solar cells  

Energy Technology Data Exchange (ETDEWEB)

Direct current motors are used in photovoltaic systems. Important characteristics of electric motors are the starting to rated current and the torque ratios. These ratios are dictated by the size of the solar cell array and are different for the various dc motor types. The paper deals with the calculation of the starting to rated current ratio and starting to rated torque ratio of the permanent magnet, separately, series and shunt excited motors when powered by solar cells for the two cases: where (1) the system includes a maximum-power-point-tracker (MPPT) and (2) without an MPPT. Comparing these two cases, one gets a torque magnification of about 3 for the permanent magnet motor and about 7 for other motor types at rated design insolation. The calculation of the torques may assist the PV system designer to determine the advantage of including an MPPT in the ...

1993-03-01

209

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system; Interventionelle MR-Tomographie: Klinische Erfahrungen mit einem 1,5 Tesla System  

Energy Technology Data Exchange (ETDEWEB)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)

1997-05-01

210

Spin correlations in the frustrated square lattice Pb{sub 2}VO(PO{sub 4}){sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The new frustrated square-lattice system, Pb{sub 2}VO(PO{sub 4}){sub 2}, has been investigated using polarised neutron scattering. From these studies, made on powdered samples, we have determined the nature of the exchange interactions and the magnetic ordering for this novel quantum magnet. Quantum order from disorder occurs at low temperature, and the ground state observed below the Neel temperature T {sub N}{approx}3.7 K is a collinear antiferromagnet. At room temperature there are no magnetic correlations and it is possible to model the scattering with the V{sup 4+} magnetic form factor. However, at T{approx}20 K, a temperature well into the paramagnetic phase, magnetic correlations are observed, and these spin correlations have been modelled using a high-temperature series expansion. Ferromagnetic nearest-neighbour exchange J {sub 1}{approx}-2 K and ...

2007-03-15

211

New short-range electromagnetic current in the deuteron  

International Nuclear Information System (INIS)

A new model for short-range isoscalar current in the deuteron and NN system is developed and tested on a variety of isoscalar magnetic observables such as the deuteron magnetic moment, magnetic form factor, and the circular polarization of photons at n"#->#p radiative capture at thermal neutron energies. The model for electromagnetic two-nucleon current proposed in the paper is based on generation of an intermediate dibaryon in the short-range NN interaction. This intermediate dibaryon, in turn, is treated within the new model for intermediate and short-range NN interaction recently proposed by the present authors. The transition current model developed here satisfies the current conservation relation by the construction. Our calculations have demonstrated that the new current model, using only one parameter (with a clear physical meaning), is able to describe, in very good agreement with the ...

2007-02-01

212

Measurement of the static magnetization of solid "3He through the ordering temperature  

International Nuclear Information System (INIS)

The static magnetization of solid "3He contained in sintered copper was measured. The results of the density on the melting curve show that below 5 mK, the magnetization M rises above the Curie-Weiss law extrapolated from high temperature. It reaches a maximum of twice as much as the Curie Weiss law value at temperature Tm, which would be somewhat below 1.25 mK if the system could be warmed up at infinitesimally slow rate. Below Tm, M decreases rapidly to 0.4 of its maximum, then appears to become independent of temperature. The previously reported decrease of specific heat below the Curie-Weiss law value in the range below 4 mK is apparently related to the increase of M in that range. At the low temperature end, apparent decrease of M is due to the fact that there is background magnetization which is out of equilibrium with the thermometer when there is solid "3He in the sample cell. It is suspected ...

1977-09-09

213

Crystal electric field excitations in the cerium compound CeRh{sub 3}B{sub 2} studied by inelastic neutron scattering  

Energy Technology Data Exchange (ETDEWEB)

We have performed inelastic neutron scattering (INS) experiments on CeRh{sub 3}B{sub 2} at various temperatures to obtain direct information on the crystal electric field (CEF) in this compound, which exhibits some very peculiar magnetic properties for a Ce system: it is ferromagnetic with an unusually high Curie temperature (115 K), which contrasts with a strongly reduced and anisotropic magnetization (0.4 {mu}{sub B}/fu within the c-plane of the hexagonal structure). Measurements with high incident energies show only one well defined magnetic excitation around 150 meV, its exact position varying with the temperature. These results, combined with our previous data of magnetization and magnetic form factor, have permitted us to determine the CEF energy level scheme taking into account the two J multiplets of the Ce{sup 3+} ion. Information on the ground state ...

2007-12-19

214

Crystal electric field excitations in the cerium compound CeRh_3B_2 studied by inelastic neutron scattering  

International Nuclear Information System (INIS)

We have performed inelastic neutron scattering (INS) experiments on CeRh_3B_2 at various temperatures to obtain direct information on the crystal electric field (CEF) in this compound, which exhibits some very peculiar magnetic properties for a Ce system: it is ferromagnetic with an unusually high Curie temperature (115 K), which contrasts with a strongly reduced and anisotropic magnetization (0.4 #mu#_B/fu within the c-plane of the hexagonal structure). Measurements with high incident energies show only one well defined magnetic excitation around 150 meV, its exact position varying with the temperature. These results, combined with our previous data of magnetization and magnetic form factor, have permitted us to determine the CEF energy level scheme taking into account the two J multiplets of the Ce"3"+ ion. Information on the ground state (quasielastic ...

2007-12-19

215

The Bevatron liquid nitrogen circulation system  

Science.gov (United States)

A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.

1987-03-01

216

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass ...

2005-03-17

217

Design and implementation of the BESIII detector-control system  

Energy Technology Data Exchange (ETDEWEB)

In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has been developed for the ...

2008-07-21

218

Magnetic nanoparticle detection using nano-SQUID sensors  

International Nuclear Information System (INIS)

We demonstrate detection of a single core-shell magnetite-silica nanoparticle (outer diameter #approx#120 nm, moment #approx#10"4#mu#_B) using an Nb dc superconducting quantum interference device (SQUID) with the loop size of 350 nm operational at T < 10 K. The system noise was minimized down to 0.2 #mu##PHI#_0 Hz"-"1"/"2 using a cryogenic SQUID series array pre-amplifier. Initial measurements of an individual magnetic nanoparticle were performed and a clear change of the noise spectra of the nano-SQUID was detected at low frequencies in the presence of the nanoparticle. Similar behaviour was confirmed with an FePt nanoparticle with a larger magnetic moment (diameter #approx#150 nm, moment #approx#10"6#mu#_B). Thus, we demonstrate a magnetic sensor based on a dc nano-SQUID and enabling detection of small moments (potentially down to a few electron spins). Such a sensor is of considerable significance ...

2010-12-01

219

Anisotropic magnetism in hybridizing uranium systems  

International Nuclear Information System (INIS)

The isostructural uranium monopnictides and monochalcogenides have become prototype systems in actinide research with respect to their unusual magnetic properties. We have investigated the origins in the electronic structure of the variation in magnetic behavior as the degree of 5f-electron localization changes from localized to itinerant on going up the pnictogen or chalcogen column, thus decreasing the U-U separation. We have applied a synthesis of: (1) A phenomenological theory of orbitally driven magnetic ordering which includes both the hybridization-induced and the RKKY exchange interactions on an equal footing, and (2) Ab initio electronic structure calculations, based on the linear-muffin-tin-orbital method, allowing a first-principles evaluation of the parameters entering the model Hamiltonian. We have investigated systematically characteristic trends and changes of the 5f-state resonance ...

220

Sterically stabilized water based magnetic fluids: Synthesis, structure and properties  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluids (MFs), prepared by chemical co-precipitation followed by double layer steric and electrostatic (combined) stabilization of magnetite nanoparticles dispersed in water, are presented. Several combinations of surfactants with different chain lengths (lauric acid (LA), myristic acid (MA), oleic acid (OA) and dodecyl-benzene-sulphonic acid (DBS)) were used, such as LA+LA, MA+MA, LA+DBS, MA+DBS, OA+DBS, OA+OA and DBS+DBS. Static light scattering, transmission electron microscopy, small angle neutron scattering, magnetic and magneto-rheological measurements revealed that MFs with MA+MA or LA+LA biocompatible double layer covered magnetite nanoparticles are the most stable colloidal systems among the investigated samples, and thus suitable for biomedical applications.

2007-04-15

221

Spin compensation cloud and the Kondo effect  

Energy Technology Data Exchange (ETDEWEB)

We have used polarised neutrons to measure the integrated magnetic cross-section of a dilute alloy of Ce in Y a Kondo system, T{sub K}{approx}40 K. Previous polarised neutron measurements of the field-induced magnetic form factor found no anomalies that could be attributed to the formation of a spin compensation cloud around the Ce ion. The present measurements, focused on the diffuse low-Q range, represent information over a very wide length scale in real space. Again, they show no changes in the Q-dependence of the form-factor at low temperatures that could be attributed to the formation of a spin compensation cloud. An alternative interpretation of the phenomenon based on the dynamical magnetic susceptibility of Y-Ce is proposed.

2008-04-01

222

Spin compensation cloud and the Kondo effect  

International Nuclear Information System (INIS)

We have used polarised neutrons to measure the integrated magnetic cross-section of a dilute alloy of Ce in Y a Kondo system, T_K#approx#40 K. Previous polarised neutron measurements of the field-induced magnetic form factor found no anomalies that could be attributed to the formation of a spin compensation cloud around the Ce ion. The present measurements, focused on the diffuse low-Q range, represent information over a very wide length scale in real space. Again, they show no changes in the Q-dependence of the form-factor at low temperatures that could be attributed to the formation of a spin compensation cloud. An alternative interpretation of the phenomenon based on the dynamical magnetic susceptibility of Y-Ce is proposed.

2008-04-01

223

Spectrograph for free-electron laser experiments  

International Nuclear Information System (INIS)

The design and construction of a Browne-Buechner type round pole face magnetic electron spectrograph is described. The design is based on the first order transfer properties of the bending magnet including the focal surface, dispersion, magnification and resolution. Second order aberrations are compared wit numerical ray tracing results using measured field data to simulate the magnet. The numerical results are also compared with floating wire measurements on the system. Agreement is within one part in 10"4. Data extraction from the instrument is done with an array of copper detectors placed along the focal surface. The spectrograph has been successfully employed in free-electron laser (FEL) experiments for over a year.

1983-03-21

224

On the disrupted magnetic braking model for the period gap of cataclysmic variables  

International Nuclear Information System (INIS)

The disrupted magnetic braking theory for the period gap of cataclysmic variable systems is used to study the binary evolution of low-mass main-sequence-like stars with white dwarf companions. The model is able to reproduce the observed location and width of the gap provided that the average mass transfer rates above the upper edge of the gap are greater than about 1.9 x 10 to the -9th solar masses/yr. For the case of angular momentum loss by magnetic braking, the slope of the mass transfer rate with respect to orbital period is shown to range from 3.4 to 3.7. For the evolutionary sequences considered, the He-3 abundance at the surface of the secondary exceeds 0.0015 after the complete mixing phase, resulting in modifications in the nuclear burning development of nova explosions. 31 refs.

225

Magnetic properties of Fe-Co-Mo-Cu-B nanocrystalline ribbons with stressing surfaces  

British Library Electronic Table of Contents (United Kingdom)

Magnetic properties of Fe-Co-Mo-Cu-B alloy system with Co up to 26at.% were investigated. After proper thermal treatment, the nanocrystalline grain remains tiny, the density hardly increases, but the room-temperature saturation attains 1.5T mainly due to a high enough Curie temperature. The generally observed slant hysteresis loops point to ribbon surfaces, which stress the ribbon interior and induce a specific magnetoelastic contribution to hard-ribbon-axis magnetic anisotropy even after vacuum annealing. The effect does not come from cobalt but rather from the lack of silicon. Partial removal of the surfaces resulted in a decrease of the loop tilt.

2011-01-01

226

Magnetic field processing of liquid-crystalline thermosets  

Energy Technology Data Exchange (ETDEWEB)

LCTs (liquid crystal thermosets) have significant potential as a new class of structural materials. Through appropriate processing techniques using magnetic fields, the authors can orient the liquid-crystalline molecules and significantly improve the mechanical properties of the material. Most notably, the use of magnetic field processing can increase the tensile modulus threefold over the modulus in the unoriented material. This modulus value is only obtained in conventional epoxies in highly filled systems. Further investigation of the full set of mechanical properties of oriented LCTs will validate their approach to processing these materials. In the long run, the development of an economical and viable route to oriented LCTs will provide opportunities to expand the use of lightweight polymers in structural applications.

1997-08-01

227

Combined effect of magnetic field and heat absorption on unsteady free convection and heat transfer flow in a micropolar fluid past a semi-infinite moving plate with viscous dissipation using element free Galerkin method  

British Library Electronic Table of Contents (United Kingdom)

The fully developed electrically conducting micropolar fluid flow and heat transfer along a semi-infinite vertical porous moving plate is studied including the effect of viscous heating and in the presence of a magnetic field applied transversely to the direction of the flow. The Darcy-Brinkman-Forchheimer model which includes the effects of boundary and inertia forces is employed. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. Profiles for velocity, microrotation and temperature are presented for a wide range of plate velocity, viscosity ratio, Darcy number, Forchhimer number, magnetic field parameter, heat absorption ...

2010-01-01

228

Using PCAR to study Cu/Co bilayers  

International Nuclear Information System (INIS)

For spintronic applications it is important to establish how efficiently spins can be injected from a magnetic material into a non-magnetic material and the distance over which those spins survive. It is thought that spin polarised transport current can be determined by using the suppression of the Andreev reflection between a superconductor and the spin polarised material (Science 282 (1998) 85). Cu/Co bilayers are potentially an ideal test system for such study. In this paper we assess the feasibility of using point contact Andreev reflection spectroscopy to address this problem using a superconducting niobium tip at 4.2 K.

2004-05-01

229

Studies of the correlated electron system SmB_6  

International Nuclear Information System (INIS)

We have prepared high-quality, single crystals of SmB_6 under various conditions to improve sample quality. We have measured the resistivity and magnetic susceptibility from room to liquid-helium temperatures to sort samples. We have applied pulsed magnetic fields as high as 50 T at temperatures as low as 40 mK while measuring resistivity. Our samples are of higher quality than previously known. All solvent-grown, single-crystal samples should be etched to remove a surface conductivity. (orig.).

230

Neutron diffraction study of 5f itinerant antiferromagnet UPtGa{sub 5} and UNiGa{sub 5}  

Energy Technology Data Exchange (ETDEWEB)

Magneto-striction and magnetic form factors in 5f itinerant antiferromagnets UNiGa{sub 5} and UPtGa{sub 5} are studied by means of neutron scattering. Remarkable magneto-striction was observed around T{sub N}, indicating large spin-orbit coupling in the itinerant system. The orbital magnetic moment is found to be strongly suppressed due to the hybridization of uranium 5f with Ga-4p electron.

2003-05-01

231

Magnetic susceptibility of the A-15 compound system (Vsub(1-x)Crsub(x))_3Si  

International Nuclear Information System (INIS)

The magnetic susceptibility of single and polycrystalline samples of the A-15 compounds (Vsub(1-x)Crsub(x))_3Si (0 <= x <= 1) is measured at temperatures between 4.2 and 320 K. The magnitude and the temperature dependence of the susceptibility diminish with increasing Cr concentration. Applying a peak model for the density of electronic states it is found that the change of the temperature dependence of the susceptibility with increasing Cr concentration is caused mainly by broadening of the peak in the density of electronic states. (author).

232

Increase in the upper critical magnetic field in structurally inhomogeneous superconductors  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the temperature dependence of the upper critical magnetic field, Hc2(T), of structurally inhomogeneous superconductors (e.g., ternary molybdenum chalcogenides, A-15 compounds, transition metal alloys, and amorphous films) are investigated analytically. The MWGH equation for Hc2(T) is generalized to the case of weakly inhomogeneous systems with a characteristic inhomogeneity scale much smaller than the effective coherence length. It is shown that an increase in the dispersion of the diffusion coefficient leads to an increase in the slope and width of the linear section of the Hc2(T) curve. 11 references.

1987-11-01

233

A simple route to a tunable electromagnetic gateway  

CERN Document Server

Transformation optics is used to design a gateway that can block electromagnetic waves but allows the passage of other entities. Our conceptual device has the advantage that it can be realized with simple materials and structural parameters and can have a reasonably wide bandwidth. In particular, we show that our system can be implemented by using a magnetic photonic crystal structure that employs a square ray of ferrite rods, and as the field response of ferrites can be tuned by external magnetic fields, we end up with an electromagnetic gateway that can be open or shut using external fields. The functionality is also robust against the positional disorder of the rods that made up the photonic crystal.

2009-01-01

234

Tools and methods for implementing the control systems on the Mirror Fusion Test Facility  

Energy Technology Data Exchange (ETDEWEB)

Installation of the major hardware subsystems for MFTF is nearing completion. These subsystems include the Fusion Chamber System, the eighty KV Neutral Beam System, the Superconducting Magnet System, and the Personnel Safety System. The Local Controls group has undertaken a uniform aproach to implementing the control systems for all of these hardware subsystems. This approach has two major aspects: (1) to provide a stand-alone computer control system with a remote, portable terminal so that computer control can be provided at the site of the hardware for initial testing, (2) to provide hardware simulators so that the complicated MFTF computer control system can be tested independent of the hardware. The software and hardware tools which were developed to carry out this plan will be described. Our experiences with ...

1981-09-29

235

Direct energy conversion for IEC fusion for space applications  

Energy Technology Data Exchange (ETDEWEB)

The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique ...

2000-08-01

236

Collisionless driven reconnection in an open system  

Energy Technology Data Exchange (ETDEWEB)

Particle simulation studies of collisionless driven reconnection in an open system are presented. Collisionless reconnection evolves in two steps in accordance with the formation of two current layers, i.e., an ion current layer in the early ion phase and an electron current layer in the late electron phase. After the electron current layer is formed inside the ion current layer, the system relaxes gradually to a steady state when convergent plasma flow is driven by an external electric field with a narrow input window. On the other hand, when the convergent plasma flow is driven from the wide input window, magnetic reconnection takes place in an intermittent manner, due to the frequent formation of magnetic islands in the vicinity of neutral sheet. (author)

2000-06-01

237

Ion temperature gradient modes in toroidal helical systems  

Energy Technology Data Exchange (ETDEWEB)

Linear properties of ion temperature gradient (ITG) modes in helical systems are studied. The real frequency, growth rate, and eigenfunction are obtained for both stable and unstable cases by solving a kinetic integral equation with proper analytic continuation performed in the complex frequency plane. Based on the model magnetic configuration for toroidal helical systems like the Large Helical Device (LHD), dependences of the ITG mode properties on various plasma equilibrium parameters are investigated. Particularly, relative effects of {nabla}B-curvature drifts driven by the toroidicity and by the helical ripples are examined in order to compare the ITG modes in helical systems with those in tokamaks. (author)

2000-04-01

238

Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination  

Energy Technology Data Exchange (ETDEWEB)

The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for ...

2000-07-01

239

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The process is observed to be dominated by the ...

1988-11-01

240

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...

1995-11-01

241

Absence of isoscalar monopole strength in {sup 56}Fe and {sup 58}Ni  

Energy Technology Data Exchange (ETDEWEB)

Measurements with 240 MeV {alpha} particle inelastic scattering with excellent peak/background ratios at small scattering angles including 0{degrees} were made on {sup 56}Fe and {sup 58}Ni using the multipole-dipole-multipole spectrometer at Texas A&M University. Beam was delivered to the spectrometer through a beam analysis system having two bends of 88{degrees} and 87{degrees} respectively. A slit placed after the first 88{degrees} bend was used to define the beam. Slits placed after the second bend (87{degrees}) were used to eliminate slit scattered particles. Comparison of the results of a multiple peak fit to the{sup 58}Ni spectra after continuum subtraction to DWBA calculations revealed about 32% of the E0 EWSR and 58% of the E2 EWSR in the peak, in agreement with previous works. Fits to the angular distribution of the continuum for E{sub x} = 25 MeV show that <15% of the E0 EWSR is present in the continuum. ...

1995-10-01

242

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.

1995-12-31

243

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).

1995-11-01

244

M 1 decay rates of heavy quarkonia with a nonsingular potential  

Energy Technology Data Exchange (ETDEWEB)

We use a nonsingular-potential model for heavy quarkonia proposed by Gupta, Repko, and Suchyta to calculate the transition amplitudes for the magnetic-dipole ({ital M}1) one-photon radiative decays of the {ital c{bar c}} and {ital b{bar b}} bound systems. The wave functions of the bound systems are calculated by a nonperturbative treatment. The results are in better agreement with the experimental data than those predicted using other potential models.

1991-09-01

245

Dimensional metrology and positioning operations: basics for a spatial layout analysis of measurement systems  

CERN Document Server

Dimensional metrology and positioning operations are used in many fields of particle accelerator projects. This lecture gives the basic tools to designers in the field of measure by analysing the spatial layout of measurement systems since it is central to dimensional metrology as well as positioning operations. In a second part, a case study dedicated to a synchrotron storage ring is proposed from the detection of the magnetic centre of quadrupoles to the orbit definition of the ring.

2010-01-01

246

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

247

Magnetic braking in differentially rotating, relativistic stars  

International Nuclear Information System (INIS)

We study the magnetic braking and viscous damping of differential rotation in incompressible, uniform density stars in general relativity. Differentially rotating stars can support significantly more mass in equilibrium than nonrotating or uniformly rotating stars, according to general relativity. The remnant of a binary neutron star merger or supernova core collapse may produce such a 'hypermassive' neutron star. Although a hypermassive neutron star may be stable on a dynamical time scale, magnetic braking and viscous damping of differential rotation will ultimately alter the equilibrium structure, possibly leading to delayed catastrophic collapse. Here we treat the slow-rotation, weak-magnetic field limit in which E_r_o_t<magnetic energy, and W is the gravitational binding energy of the star. We assume the ...

2004-02-15

248

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

250

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

251

High Voltage Measurements on Nine PFNs for the LHC Injection Kicker Systems  

CERN Document Server

Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions ...

2005-01-01

252

A Wide-Band Electromagnetic Impedance Profiling System forNon-Invasive Subsurface Characterization  

Energy Technology Data Exchange (ETDEWEB)

A non-invasive, wide-band electromagnetic (EM) impedance difference system for shallow subsurface electrical structure characterization in environmental and engineering problems has been developed at the Lawrence Berkeley National Laboratory (LBNL). Electrical parameters of interest are electrical conductivity and dielectric permittivity that are deduced from the impedance difference data. The prototype system includes a magnetic loop transmitter, which operates between 0.1 MHz and 100 MHz, an electrical dipole antenna for observing the electric field, and a loop antenna for measuring the magnetic field.All antennas are mounted on a cart made of non-metallic material for easy movement of the whole array for profiling. Surface EM impedance difference is obtained by taking the difference of the ratios of the electric fields to the magnetic fields at selected frequencies at two ...

2004-12-17

253

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

254

Design and operating experience of a 40 MW, highly-stabilized power supply  

Energy Technology Data Exchange (ETDEWEB)

Four 10 MW, highly-stabilized power supply modules have been installed at the National High Magnetic Field Laboratory in Tallahassee, FL, to energize water-cooled, resistive, high-field research magnets. The power supply modules achieve a long term current stability if 10 ppM over a 12 h period with a short term ripple and noise variation of <10 ppM over a time period of one cycle. The power supply modules can operate independently, feeding four separate magnets, or two, three or four modules can operate in parallel. Each power supply module consists of a 12.5 kV vacuum circuit breaker, two three-winding, step-down transformers, a 24-pulse rectifier with interphase reactors, and a passive and an active filter. Two different transformer tap settings allow rated dc supply output voltages of 400 and 500 V. The rated current of a supply module is 17 kA and each supply module has a one-hour overload capability of 20 kA. The ...

1995-07-01

255

Rotating magnetic tensor gradiometry and a superconducting implementation  

International Nuclear Information System (INIS)

This work describes the theoretical basis for a new concept rotating magnetic tensor gradiometer. The rotating gradiometer consists of an approximately axial or transverse gradiometer which is made to rotate about a perpendicular axis so that the direction of sensitivity is continually changing. It is demonstrated for the first time that the rotation separates gradient components of progressively higher-order in the frequency domain and enables absolute-value measurements of all components of the first-order magnetic gradient tensor, even if the magnetic sensors comprising the gradiometer are intrinsically incapable of absolute-value detection. In addition, the rotating gradiometer concept has a number of other advantages: the gradiometer imbalance is no longer directly determined by the engineering precision, the DC and low-frequency performance of the instrument is not limited by the performance of the detectors in these ...

2009-07-01

256

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...

2008-06-01

257

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were presented as color-coded anatomically-mapped ...

258

Analysis of the requirements for economic magnetic fusion  

Energy Technology Data Exchange (ETDEWEB)

A generic reactor model is used to examine the economic viability of electricity generation by magnetic fusion. The simple model uses components which are representative of those used in previous reactor studies of deuterium-tritium burning tokamaks, stellarators, bumpy tori, reverse field pinches and tandem mirrors. Conservative costing assumptions are made. The generic reactor is not a tokamak but rather it is intended to emphasize what is common to all magnetic fusion reactors. The reactor uses a superconducting toroidal coil set to produce the dominant magnetic field. To this extent it is a less good approximation to systems, such as the reversed field pinch in which the main field is produced by a plasma current. The main output of the study is the cost of electricity as a function of the weight and size of the fusion core - blanket, shield, structure and coils. The model shows that a 1200 MW/sub ...

1986-01-01

259

Synthesis of magnetic particles via a cationic-anionic surfactant vesicle method  

Energy Technology Data Exchange (ETDEWEB)

In this work, a mixed cationic--anionic [i.e. cetyltrimethylammonium bromide-sodium octyl sulphate] surfactant system was used to synthesize the magnetite particles. The loading content of iron ions (Fe{sup 3+} and Fe{sup 2+}) into the surfactant system was varied to study its effect on the formation of magnetite, magnetic and morphological properties of the magnetite particles encapsulated by the surfactant vesicles. It has been verified that the vesicle-encapsulated magnetite particles with sizes from 100 to 200 nm were formed, which were almost independent of the loading content of iron ions. However, the morphological structure of the magnetite particles was dependent on the loading content of iron ions and there existed an optimal loading content for a full packing of the surfactant vesicles with the magnetite particles.

2006-10-15

260

Synthesis of magnetic particles via a cationic-anionic surfactant vesicle method  

International Nuclear Information System (INIS)

In this work, a mixed cationic--anionic [i.e. cetyltrimethylammonium bromide-sodium octyl sulphate] surfactant system was used to synthesize the magnetite particles. The loading content of iron ions (Fe"3"+ and Fe"2"+) into the surfactant system was varied to study its effect on the formation of magnetite, magnetic and morphological properties of the magnetite particles encapsulated by the surfactant vesicles. It has been verified that the vesicle-encapsulated magnetite particles with sizes from 100 to 200 nm were formed, which were almost independent of the loading content of iron ions. However, the morphological structure of the magnetite particles was dependent on the loading content of iron ions and there existed an optimal loading content for a full packing of the surfactant vesicles with the magnetite particles.

2006-10-01

261

Studies of interlayer magnetic coupling in all-semiconductor superlattices by means of neutron scattering techniques  

International Nuclear Information System (INIS)

An overview on neutron scattering studies of ferromagnetic and antiferromagnetic all-semiconductor superlattices is presented. Diffraction experiments on MnTe/CdTe, MnTe/ZnTe and EuTe/PbTe superlattices show pronounced correlations between the MnTe and EuTe layers across the non-magnetic spaces, even though these layers are antiferromagnetic and the systems are nearly-insulating. Current theory status of these systems is discussed. Diffractometry and reflectometry data from EuS/PbS superlattices reveal pronounced antiferromagnetic coupling between the ferromagnetic EuS block. First polarized neutron reflectometry data from superlattices prepared of a novel ferromagnetic 'spintronics' material, Ga(Mn)As are also presented. (author)

2001-09-23

262

Direct energy recovery with ac electric power output  

Energy Technology Data Exchange (ETDEWEB)

A concept of direct energy recovery system applying an alternating or rotating magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. Nearly same amounts of residual positive and negative hydrogen-isotope ion beams with beam energy of {approx}1 MeV are produced in an NNB using a gas neutralizing cell. Consequently, a recovered energy is obtained directly in the form of ac electric power, if these positive- and negative-ion beams are alternated or rotated and introduced to two or more recovery electrodes in turn by an alternating or rotating magnetic field. This concept will greatly reduce a technological difficulty in regeneration of a recovered electric energy with such a very high voltage. (author).

1994-12-31

263

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

264

Construction and development of a UV free electron laser under the cooperation of Nihon U, KEK, PNC, ETL and Tohoku U  

Energy Technology Data Exchange (ETDEWEB)

The construction and the development of a UV free electron laser have been started under the cooperation of Nihon U, KEK, PNC, ETL and Tohaku U. The project requires a 100MeV S-band electron linear accelerator to expand the oscillation of FEL using fundamental mode to the UV region. The injection system consists of a thermionic RF-gun with a LaB cathode and an {alpha} magnet for magnetic bunching. We are studying to reduce the back-bombardment electrons to realize the macropulse length of 20{mu}sec. Electron beams, up to the energy of 100MeV, are injected into the optical oscillators. Changing the accelerating energy and/or undulator parameters, this system will cover the range from infrared to ultraviolet for the applications in various fields.

1995-12-31

265

Status and Challenges of the LHC Construction  

CERN Document Server

The LHC is designed to provide proton beams of 7 TeV and nominal luminosity of 10**34 cm**-2s**-1. This objective is achieved at an affordable cost by pushing all major collider components to the limits of technology, by upgrading the existing CERN accelerators and infrastructure, and by involving the technical expertise, resources and dedication of accelerator laboratories world-wide. Following a decade of intensive R&D and technical validation of major collider systems, the LHC construction is now fully underway. Major industrial contracts have been awarded and are in execution for the procurement of the magnet, cryogenics and other systems. In this report, the status of the design and construction of the major LHC systems is presented.

2001-01-01

266

HINS Linac front end focusing system R&D  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes current status of an R&D program to develop a focusing system for the front end of a superconducting RF linac. Superconducting solenoids will be used as focusing lenses in the low energy accelerating sections of the front end. The development of focusing lenses for the first accelerating section is in the production stage, and lens certification activities are in preparation at FNAL. The report contains information about the focusing lens design and performance, including solenoid, dipole corrector, and power leads, and about cryogenic system design and performance. It also describes the lens magnetic axis position measurement technique and discusses scope of an acceptance/certification process.

2008-08-01

267

Final design and manufacturing of the Cryolegs of the W7-X-superconducting coil support system  

Energy Technology Data Exchange (ETDEWEB)

One of the most complicated tasks during the assembly of the Wendelstein W7-X is the installation of the superconductive coil system. The entire magnet system is enclosed between the Outer Vessel and the plasma vessel in high vacuum at 4 K. The coils are supported by a support structure, the Central Support Structure (CSS). The CSS carries all 70 coils, and it is designed as a closed ring made of 5 modules (10 half modules). The whole structure is supported by 10 Cryolegs which rest on the machine base. This paper describes the final design and manufacture of these Cryolegs.

2008-12-15

268

Real-time orbit feedback at the APS.  

Energy Technology Data Exchange (ETDEWEB)

A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS ...

1998-06-18

269

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

270

High-precision Penning-Trap measurements of light-ion masses  

International Nuclear Information System (INIS)

The UW-Penning Trap Mass Spectrometer (PTMs) is ideally suited for high precision measurements of atomic masses throughout the periodic table upon using highly-stripped ions. However, at the present time, this device has been applied extensively to the light elements ("1H, "2H, "3H, "3He, "4He, "1"2C, "1"3C, "1"4N, "1"6O) due to their fundamental importance. Atomic masses follow immediately from a comparison with some multiply-charged carbon ion, after correcting for the lost electrons and their corresponding binding energies. For instance, the most recent C"5"+/C"6"+ comparison yielded a discrepancy of -0.30(33) ppb, limited only by the magnetic field instability for a 40-h run. The initial emphasis on hydrogen has now produced a 1-ppb value for the proton's atomic mass and similar work with deuterium has yielded a 2.5-ppb value for the neutron's atomic mass. However, the most significant result is the "3H-"3He mass difference = 18,590.1(17) ...

1993-04-12

271

Global mode analysis of ideal MHD modes in a heliotron/torsatron system. 1. Mercier-unstable equilibria  

Energy Technology Data Exchange (ETDEWEB)

By means of a global mode analysis of ideal MHD modes for Mercier-unstable equilibria in a planar axis L=2/M=10 heliotron/torsatron system with an inherently large Shafranov shift, the conjecture from local mode analysis for Mercier-unstable equilibria given in [N. Nakajima, Phys. Plasmas 3, 4556 (1996)] has been confirmed and the properties of pressure-driven modes, namely, ballooning modes and interchange modes, inherent to such three-dimensional systems have been clarified. The change of the local magnetic shear due to the Shafranov shift, which is related to toroidicity, reduces the field line bending stabilizing effects on ballooning modes. According to the degree of the reduction of the local magnetic shear by the Shafranov shift, the Mercier-unstable equilibria are categorized into toroidicity-dominant (strong reduction) and helicity-dominant (weak reduction) Mercier-unstable equilibria. Since ...

1998-12-01

272

Measurement of electron energy fluence spectra from electron beam therapy machines  

Energy Technology Data Exchange (ETDEWEB)

A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. CYLTRAN, a coupled electron-photon Monte Carlo transport code, ...

1984-01-01

273

Infrared Observations During the Secondary Eclipse of HD 209458b I. 3.6-Micron Occultation Spectroscopy Using the VLT  

CERN Document Server

We search for an infrared signature of the transiting extrasolar planet HD 209458b during secondary eclipse. Our method, which we call `occultation spectroscopy,' searches for the disappearance and reappearance of weak spectral features due to the exoplanet as it passes behind the star and later reappears. We argue that at the longest infrared wavelengths, this technique becomes preferable to conventional `transit spectroscopy'. We observed the system in the wing of the strong nu-3 band of methane near 3.6 microns during two secondary eclipses, using the VLT/ISAAC spectrometer at a spectral resolution of 3300. Our analysis, which utilizes a model template spectrum, achieves sufficient precision to expect detection of the spectral structure predicted by an irradiated, low-opacity (cloudless), low-albedo, thermochemical equilibrium model for the exoplanet atmosphere. However, our observations show no evidence for the presence of this spectrum ...

2003-01-01

274

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is ...

1988-10-01

275

A gas-jet ECR ion source at TRIGA-SPEC  

International Nuclear Information System (INIS)

The TRIGA-SPEC experiment has been installed recently at the research reactor TRIGA Mainz. Ground state properties like masses, charge radii, spins, and moments of short-lived nuclides can be determined with very-high precision using the Penning trap mass spectrometer TRIGA-TRAP, and the collinear laser spectroscopy setup TRIGA-LASER. Short-lived neutron-rich radionuclides in the mass range 80 < A < 140 are produced by thermal neutron induced fission of e.g. U-235, Pu-239 or Cf-249, respectively. For the extraction and ionization of the fission products a gas-jet system is coupled to a 2.45-GHz ECR ion source for the production of singly charged ions. The gas-jet has been tested on-line and fission products have been extracted. First off-line tests of the ion source have been performed successfully with argon gas. The results of the commissioning test of the ion source and the on-line coupling of the experiments are presented.

2010-03-08

276

The cross sections of (n, x) nuclear reactions on Pb and Bi at the neutron energy 14.6 MeV  

International Nuclear Information System (INIS)

... compton spectrometers cross sections energy resolution energy-level transitions

2000-06-14

277

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

278

Neutron time-of-flight spectroscopy and the reaction "8"8Sr("3He,n)"9"0Zr  

International Nuclear Information System (INIS)

... states helium 3 reactions ion sources mev range 10-100 neutron spectrometers

279

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

280

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

281

Magnetic and superconducting quantum critical points of heavy-fermion systems  

Energy Technology Data Exchange (ETDEWEB)

Two examples of heavy-fermion systems are presented : CePd{sub 2}Si{sub 2}, an antiferromagnet with a quantum critical point at P{sub C}=28 kbar and UGe{sub 2} an itinerant ferromagnet which transits in a paramagnetic phase above P{sub C}=16 kbar. In CePd{sub 2}Si{sub 2} the superconductivity domain is centered on P{sub C}. Special attention was given to the superconducting and magnetic anomalies at their superconducting and Neel temperatures. In UGe{sub 2} superconductivity appears in 9 kbar at a temperature T{sub S}, more than two orders of magnitude lower than the Curie temperature; furthermore, it occurs only on the magnetic border (P<P{sub C}). Another characteristic temperature T{sub X} is detected by resistivity; the zigzag uranium chain of the lattice may favor a supplementary nesting in the majority spin band.

2001-05-01

282

Field-induced valence transition of Eu(Pd{sub 1{minus}x}Pt{sub x}){sub 2}Si{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The magnetic susceptibility and high-field magnetization have been measured for the intermediate valence system Eu(Pd{sub 1{minus}x}Pt{sub x}){sub 2}Si{sub 2} with 0{le}x{le}0.15. A first-order valence transition is observed for all the compounds under high field of 100 T at low temperatures. This valence transition is of first order accompanied with a large hysteresis, which is in contrast to a continuous valence change against temperature. Based on the interconfigurational fluctuation (ICF) model, the temperature- and field-induced valence transitions are discussed. It is found that a first-order valence transition can be induced by magnetic field, even if the system shows a continuous valence transition against temperature. Metamagnetic behavior at finite temperatures is also understood qualitatively by the ICF model. {copyright} {ital 1997} {ital The American Physical Society}

1997-05-01

283

Evolution of magnetic structures in the UNi{sub 2}Si{sub 2}-UPd{sub 2}Si{sub 2} system  

Energy Technology Data Exchange (ETDEWEB)

The influence of Pd-Ni substitution on the formation of magnetic phases in the tetragonal U(Ni{sub 1-x}, Pd{sub x}){sub 2}Si{sub 2} system and the concentration magnetic phase diagram are presented. A series of different substitutions was prepared and detailed studies by powder neutron diffraction were performed for x=0.25, 0.5 and 0.75. All compounds order antiferromagnetically and form ferromagnetic basal planes stacked along the c axis (q=(0,0,q{sub z}) propagation). The ground-state phase (AF3) of UNi{sub 2}Si{sub 2} is an uncompensated AF structure (++- stacking (q{sub z}=2/3)). In UPd{sub 2}Si{sub 2} the ground-state phase corresponds to the simple AF structure AF2 (+-+-(q{sub z}=1)). In solid solutions, no traces of the AF3 phase were found for x=0.25 and the ground-state powder patterns correspond to AF2 for x{>=}0.25. (orig.)

2002-07-01

284

Evolution of magnetic structures in the UNi_2Si_2-UPd_2Si_2 system  

International Nuclear Information System (INIS)

The influence of Pd-Ni substitution on the formation of magnetic phases in the tetragonal U(Ni_1_-_x, Pd_x)_2Si_2 system and the concentration magnetic phase diagram are presented. A series of different substitutions was prepared and detailed studies by powder neutron diffraction were performed for x=0.25, 0.5 and 0.75. All compounds order antiferromagnetically and form ferromagnetic basal planes stacked along the c axis (q=(0,0,q_z) propagation). The ground-state phase (AF3) of UNi_2Si_2 is an uncompensated AF structure (++- stacking (q_z=2/3)). In UPd_2Si_2 the ground-state phase corresponds to the simple AF structure AF2 (+-+-(q_z=1)). In solid solutions, no traces of the AF3 phase were found for x=0.25 and the ground-state powder patterns correspond to AF2 for x#>=#0.25. (orig.)

285

[Effects of 50 to 60 Hz and of 20 to 50 kHz magnetic fields on the operation of implanted cardiac pacemakers].  

Science.gov (United States)

The effect of 50 Hz and 60 Hz (frequencies of current distribution) and 20 kHz to 50 kHz (frequencies of induction cooktop) magnetic interference on implanted pacemakers have been assessed with the present generation of device technology. Sixty patients implanted in 1998 and 1999 with dual chamber pacemakers from 9 different manufacturers were monitored with telemetry while passing through, and standing between a system of two coils. They generated a 50 Hz or a 60 Hz magnetic field at 50 microT. Then, patients used a cooktop at different power. The recordings were made with the standard setting of "medically correct" sensing parameters chosen for the patients. Then pacemakers were reprogrammed to the unipolar mode, with the highest atrial (A) and ventricular (V) sensitivity that did not induce muscular inhibition while moving. Between each exposure (50 Hz, 60 Hz or 20 kHz to 50 kHz), the pacemaker programmation was ...

2003-04-01

286

TIME EVOLUTION OF CORONAL MAGNETIC HELICITY IN THE FLARING ACTIVE REGION NOAA 10930  

International Nuclear Information System (INIS)

To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through the surface. (2) The ...

2010-09-10

287

Synthesis of colloidal silver iron oxide nanoparticles--study of their optical and magnetic behavior.  

Science.gov (United States)

Silver iron oxide nanoparticles of fairly small size (average diameter approximately 1 nm) with narrow size distribution have been synthesized by the interaction of colloidal beta- Fe2O3 and silver nanoparticles. The surface morphology and size of these particles have been analyzed by using atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Their structural analysis has been carried out by employing x-ray diffraction (XRD), selected-area electron diffraction (SAED), optical and infrared (IR) spectroscopic techniques. The ageing of these particles exhibits the formation of self-assembly, possibly involving weak supramolecular interactions between Ag(I)O4 and Fe(III)O4 species. These particles display the onset of absorption in the near-infrared region and have higher absorption coefficient in the visible range compared to that of its precursors. Magnetic measurements reveal an interesting ...

2009-07-01

288

Structure and magnetic properties of the UNi_1_0_-_xFe_xSi_2 system and "2"9Si nuclear magnetic resonance in UNi_1_0Si_2  

International Nuclear Information System (INIS)

Structure and magnetic properties of UNi_1_0_-_xFe_xSi_2 intermetallics and "2"9Si nuclear magnetic resonance (NMR) in UNi_1_0Si_2 are investigated in a wide temperature range. Solid solutions in the exactly single-phase tetragonal form, ThMn_1_2 type, exist for x<2. The Ni and Fe atoms occupy the 8(f), 8(i) and 8(j) positions statistically, whereas the U atoms occupy the 2(a) and the Si atoms the 8(j) sites. The lattice parameters roughly follow Vegard's law. The magnetic susceptibility does not exhibit Curie-Weiss behaviour and, at about 630 K, an anomaly in the temperature dependence is observed. At low temperature, other anomalies are observed at 32 K and 45 K, for x=0.5 and 1.0 respectively. These low temperature anomalies are probably connected with magnetic ordering of a ferromagnetic character, whereas that at 630 K might result from the superparamagnetic state of Ni. Two "2"9Si NMR lines in ...

1993-09-01

289

High-Performance, Superparamagnetic, Nanoparticle-Based Heavy Metal Sorbents for Removal of Contaminants from Natural Waters  

Energy Technology Data Exchange (ETDEWEB)

We describe the synthesis and characterization of superparamagnetic iron oxide nanoparticle based heavy metal sorbents with various surface chemistries that demonstrate an excellent affinity for the separation of heavy metals in contaminated water systems (i.e. spiked Columbia river water). The magnetic nanoparticle sorbents are prepared from an easy to synthesize iron oxide precursor, followed by a simple, one-step ligand exchange technique to introduce the organic surface functionality of interest chosen to target either specific or broader classes of heavy metals. Functionalized superparamagnetic nanoparticles are excellent sorbent materials for the extraction of heavy metal contaminants from environmental and clinical samples since they are easily removed from the media once bound to the contaminant by simply applying a magnetic field. These engineered magnetic nanoparticle sorbents have an ...

2010-06-01

290

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

291

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

292

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

293

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

295

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

296

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

297

Interaction of constituents of the Yb-Pd-Si system in the range of zero to 40 at.% Yb  

International Nuclear Information System (INIS)

Interaction of Yb-Pd-Si system components is studied, isothermal cross section of this system state diagram at 870 K is constructed. Five new ternary silicides are detected in the system: YbPd_5Si_3, Yb_3Pd_2_0Si_6, YbPd_2Si, YbPd_0_,_6_7Si_1_,_3_3, YbPdSi; the existence of one more -YbPd_2Si_2, earlier known, is confirmed. Crystal structure for all the compounds detected is determined and examined. Data on the materials magnetic properties are obtained. It is assumed that YbPd_2Si, YbPd_2Si_2 and YbPdSi compounds appear to be the Condo-systems. 10 refs., 3 figs., 3 tabs.

298

Biopolymer system for permeability modification in porous media  

Energy Technology Data Exchange (ETDEWEB)

New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution ...

1995-12-31

299

The brain-derived neurotrophic factor Val66Met polymorphism is associated with reduced functional magnetic resonance imaging activity in the hippocampus and increased use of caudate nucleus-dependent strategies in a human virtual navigation task  

UK PubMed Central (United Kingdom)

Multiple memory systems are involved in parallel processing of spatial information during navigation. A series of studies have distinguished between hippocampus-dependent ‘spatial’ navigation,...Full Text Available

2011-03-01

300

Revolutionary news on superconductivity  

Energy Technology Data Exchange (ETDEWEB)

A brief article gives an update on the commercial exploitation of superconductivity by the American Superconductor Corporation. Potential applications include transmission and distribution, motors, magnetic storage systems, current limiters and transport. The company have produced a kilometre long, ''wrappable'' cable capable of carrying thousands of amps when operating at a temperature of below -140[sup o]C. (UK)

1994-09-01

301

Real time closed orbit correction system  

Energy Technology Data Exchange (ETDEWEB)

We describe a global closed orbit feedback experiment, based upon a real time harmonic analysis of both the orbit movement and the correction magnetic fields. The feedback forces the coefficients of a few harmonics near the betatron tune to vanish, and significantly improves the global orbit stability. We present the results of the experiment in the UV ring using 4 detectors and 4 trims, in which maximum observed displacement was reduced by a factor of between 3 and 4. 4 refs., 3 figs.

1989-01-01

302

Polarization characteristics of spontaneous emission and off-axis coherent gain in a free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

The polarization characteristics of spontaneous radiation from relativistic electrons moving through helical and planar wiggler fields are evaluated for imperfect beam injection. Maximum coherent gain in free-electron laser systems are seen to occur in optical fields having these polarization characteristics rather than those of the wiggler magnets. Coupling coefficients for an electron beam skewed at an angle to the optical mode are presented.

1995-11-01

303

Plasma Flow Equilibrium, Confinement Scaling Laws and Fusion Prospects of a Field Reversed Configuration  

International Nuclear Information System (INIS)

Field reversed configuration (FRC) is a prospective high ? magnetic system for high efficiency D- 3He fusion reactor. Self-consistent FRC plasma profiles and static electric field for reactor calculations are discussed in framework of the model including flow equilibrium and collisionless transport equations. The extrapolations to reactor regimes of plasma confinement scaling laws are considered.

2006-01-01

304

Neutron detection techniques for plasma diagnostics at the Joint European Torus (JET)  

International Nuclear Information System (INIS)

The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.

305

Magnetic susceptibility of (La,Ce)B_6 alloys  

International Nuclear Information System (INIS)

The impurity susceptibility chisub(m) of the Kondo system (Lasub(1-x)Cesub(x))B_6, x <= 0.018, has been measured for temperatures 0.03-8 K. The alloys show single impurity behavior for x < 0.006. In a wide temperature range chisub(m)(T) follows a Curie-Weiss law with theta=2.8 K and turns to a T"2 law at very low temperatures. (Auth.).

1977-03-01

306

Highlights of technical support to the Department of Energy, Division of Electric Energy Systems, Electric Power and Transmission Programs. Final technical report, 1980-1981  

Energy Technology Data Exchange (ETDEWEB)

A broad-based, multidisciplinary research program is being conducted to study biological effects of electric and magnetic fields from high-voltage transmission lines. Assistance and technical support for this program are reported. (DLC)

1982-02-01

307

Fusion technology  

International Nuclear Information System (INIS)

The Fusion Technology task performs analyses and systems studies of conceptual fusion reactors based upon inertial and high-#beta# magnetic confinement schemes. Progress in the areas of theoretical analysis (plasma and neutral-gas blanket models), specific reactor studies (toroidal and linear theta pinches, Z pinches, laser fusion) neutronic and nuclear data assessments, materials (metals and insulators) evaluation, and general engineering design is reported.

1976-12-01

308

Development of heavy-ion irradiation technique for single-event in semiconductor devices  

Energy Technology Data Exchange (ETDEWEB)

Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

1997-03-01

309

Computer Algebra meets Finite Elements: an Efficient Implementation for Maxwell's Equations  

CERN Document Server

We consider the numerical discretization of the time-domain Maxwell's equations with an energy-conserving discontinuous Galerkin finite element formulation. This particular formulation allows for higher order approximations of the electric and magnetic field. Special emphasis is placed on an efficient implementation which is achieved by taking advantage of recurrence properties and the tensor-product structure of the chosen shape functions. These recurrences have been derived symbolically with computer algebra methods reminiscent of the holonomic systems approach.

2011-01-01

310

Change of crystal field in the Er(Ni,Cu)Al system  

Energy Technology Data Exchange (ETDEWEB)

The ErNi{sub 1-} {sub x} Cu {sub x} Al compounds crystallize all in the hexagonal ZrNiAl-type structure. The concentration dependence of lattice constants shows a discontinuity between x=0.5 and 0.6. This structural change has no primary impact on the magnetic order in this series, but influences the crystal field. The lower part of the crystal-field energy-level schemes has been estimated from the specific-heat data.

2007-09-15

311

Change of crystal field in the Er(Ni,Cu)Al system  

International Nuclear Information System (INIS)

The ErNi_1_- _x Cu _x Al compounds crystallize all in the hexagonal ZrNiAl-type structure. The concentration dependence of lattice constants shows a discontinuity between x=0.5 and 0.6. This structural change has no primary impact on the magnetic order in this series, but influences the crystal field. The lower part of the crystal-field energy-level schemes has been estimated from the specific-heat data.

2007-09-01

312

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...

2009-03-01

313

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF ...

2011-09-01

314

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

315

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

316

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

317

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

318

Progress in construction of the LHC  

CERN Document Server

The Large Hadron Collider (LHC) project, approved by the CERN Council in December 1994, has now fully entered its construction phase, with the detailed technical definition of the major systems, and the adjudication of a number of large procurement contracts. We first recall the main features and characteristics of the LHC, report on the advances in definition of the layout and optics as well as on preparation of the injector complex, and review recent progress in the key technical systems of the main ring: magnets, cryogenics and vacuum, as well as civil construction, which has started following acceptance by authorities in the Host States.

1998-01-01

319

The effects of radiation on unsteady mhd convective heat transfer past a semi-infinite vertical porous moving surface with variable suction  

Scientific Electronic Library Online (English)

Abstract in english Numerical solutions for the effects of radiation on a MHD convective heat transfer past a semi-infinite porous plate with a magnetic field are obtained. It is assumed that the porous plate moves with a constant velocity in the direction of fluid flow, and the free stream velocity follows the exponentially increasing small perturbation law. The magnetic field acts perpendicular to the porous surface which absorbs the fluid with a suction velocity varying with time. The gov (more) erning equations for the flow are transformed into a system of nonlinear ordinary differential equations by perturbation technique and then are solved numerically by using the shooting method. The effects of the various parameters on the velocity, temperature profiles as well as the surface skin-friction and surface heat transfer are illustrated graphically.

2008-12-01

320

The effect of neutrals on the performance of plasma opening switches  

Energy Technology Data Exchange (ETDEWEB)

The authors address the question of the limitations on voltage and current transfer to loads in magnetic storage systems utilizing microsecond conduction time plasma opening switches. They propose that the limitation of performance results from neutral atoms that are not entrained into the ionized material that is driven by the magnetic field of the rising generator current. Evidence in support of this proposition is gathered from experiments performed on the Ace-4 and Hawk generators. They set forth a theory to describe the effect of neutrals on the electrical performance of plasma opening switches. The neutral gas is assumed to be present in the region between the moving plasma mass and the generator, primarily in the region in which the plasma is injected initially. The essential elements of the theory are a weak photoionization source to seed the gas with a low concentration of electrons, and joule heating accompanied ...

1996-12-31

321

Magnetically applied pressure-shear : a new technique for direct strength measurement at high pressure (final report for LDRD project 117856).  

Energy Technology Data Exchange (ETDEWEB)

A new experimental technique to measure material shear strength at high pressures has been developed for use on magneto-hydrodynamic (MHD) drive pulsed power platforms. By applying an external static magnetic field to the sample region, the MHD drive directly induces a shear stress wave in addition to the usual longitudinal stress wave. Strength is probed by passing this shear wave through a sample material where the transmissible shear stress is limited to the sample strength. The magnitude of the transmitted shear wave is measured via a transverse VISAR system from which the sample strength is determined.

2010-09-01

322

Flow visualization of liquid metal by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.

1994-12-31

323

Flow visualization of liquid metal by neutron radiography  

International Nuclear Information System (INIS)

Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.

1994-07-01

324

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line ...

2002-08-01

325

Effect of chemical composition on the structure and mechanical properties of Mn-Al-C alloys in the magnetic region  

Energy Technology Data Exchange (ETDEWEB)

The thermal stability and deformability of Mn-Al-C alloys containing 0.6 pct C are investigated experimentally as a function of excess phase content. It is shown that an increase in Mn content from 68.9 to 73.5 pct leads to increased stability of the high-temperature epsilon phase. The enrichment of the system Mn-Al-Cu in Mn and Al above the optimum composition leads to the formation of nonmagnetic excess phases, eta and beta, which reduce the magnetization of the alloy. In addition, a decrease in thermal stability is observed in the alloy with 73.5 pct Mn due to the decomposition of the ferromagnetic phase. 7 references.

1988-01-01

326

Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid  

CERN Document Server

In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.

1993-01-01

327

A numerical solution of unsteady MHD convection heat and mass transfer past a semi-infinite vertical porous moving plate using element free Galerkin method  

British Library Electronic Table of Contents (United Kingdom)

In this paper, the unsteady MHD free convection heat and mass transfer of viscous fluid flowing through a Darcian porous regime adjacent to a moving vertical semi-infinite plate under Soret and Dufour effect have been examined. Viscous dissipation effects are included in the energy equation. A uniform magnetic field is applied transversely to the direction of the flow. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. The influence of Grashof number (Gr), magnetic parameter (M), heat absorption parameter (Q), permeability parameter (K), Schmidt number (Sc), Soret number (Sr), and Dufour number (Du) on the velocity, tempera...

2010-01-01

328

MEMS-based Speckle Spectrometer  

CERN Document Server

We describe a new concept for a MEMS-based active spatial filter for astronomical spectroscopy. The goal of this device is to allow the use of a diffraction-limited spectrometer on a seeing limited observation at improved throughput over a comparable seeing-limited spectrometer, thus reducing the size and cost of the spectrometer by a factor proportional to r0/D (For the case of a 10 meter telescope this size reduction will be approximately a factor of 25 to 50). We use a fiber-based integral field unit (IFU) that incorporates an active MEMS mirror array to feed an astronomical spectrograph. A fast camera is used in parallel to sense speckle images at a spatial resolution of lambda/D and at a temporal frequency greater than that of atmospheric fluctuations. The MEMS mirror-array is used as an active shutter to feed speckle images above a preset intensity threshold to the spectrometer, thereby increasing ...

2006-01-01

329

A Study on the Design of Linear Motor with Transverse Flux Configuration for Railway Traction System  

Energy Technology Data Exchange (ETDEWEB)

According to the development of power electronic element (GTO, IGBT) nd material for electrical machines (permanent magnet, super conductor), the technology for electrical machines is now a day rapidly developing. here with, a novel electrical machine, based on the new conception of transverse flux configuration leads to a considerable increase in power density and enables simultaneously high efficiency.The transverse flux machine with PM excitation will be applied to gearless direct drives for railway traction system. The designed and measured performance of transverse machine for railway traction system revealed a great potential of system improvements to reduce linear motor mass. (author). 10 refs., 14 figs., 3 tabs.

1999-06-01

330

World`s longest and fasted inclined mine winder using permanent magnet synchronous motor; Eikyu jishaku doki dendoki wo shiyoshita sekai saicho saikosoku no shako makiage setsubi  

Energy Technology Data Exchange (ETDEWEB)

The latest inclined mine winder started operation in April, 1995 at the Kushiro Mining Station of Taiheiyo Coal Mining Co. A permanent magnet synchronous motor, a cycloconverter, and H{sub {infinity}} control are employed to complete the latest inclined mine winder. The winder is the world`s longest and fastest inclined mine winder, and the torque of the permanent magnet synchronous motor is the largest in the world. A report is made on the driving system placing emphasis on the points considered in the design. The gallery has the length of world`s longest 6,626m and the average gentle inclination of 6 degree. The worker transport car runs at the world`s fastest speed of 420m/min from the mouth to the bottom of the pit, making a round trip in 40 minutes. Speed is adjusted smoothly by the cycloconverter, and the car arrives at the destination safely in a short time due H{sub {infinity}} controlling. By the application of ...

1996-09-30

331

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

Energy Technology Data Exchange (ETDEWEB)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the ...

2005-04-01

332

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

International Nuclear Information System (INIS)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the ...

2005-04-01

333

Intensification of Harmonic Spontaneous Radiation with a Novel Undulator  

Science.gov (United States)

We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessive current in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeV electrons taking K < 1, for spontaneous radiation emitted along the axis of the system. The emission at harmonics f > 1 is greatly enhanced for the approximate square-wave ...

1998-11-01

334

Highly Porous, Water-Soluble, Superparamagnetic, and Biocompatible Magnetite Nanocrystal Clusters for Targeted Drug Delivery.  

Science.gov (United States)

Magnetic particles have become very promising materials for drug delivery. However, preparation of magnetite particles with high surface area, biocompatibility, strong magnetic response, and suitable particle size still remains a major challenge. In this report, magnetite nanocrystal clusters with high surface areas were fabricated through a solvothermal process by introducing ammonium acetate as a porogen and trisodium citrate as a surface modification agent. The porosity, which was controlled by the reactant concentration, has been investigated in detail. The surface area of the nanocrystal clusters was as high as 141?m(2) g(-1) . Ibuprofen, as a model drug, was entrapped into the magnetite carriers. The interfacial interaction between the carboxylic groups on the drug molecules and the carboxylate groups on the carriers enhanced the loading efficiency. Low cytotoxicity in MCF-7 cell and in vitro constant drug release behavior combined with ...

2011-09-27

335

Effects of transverse magnetic field, Prandtl number and Reynolds number on non-Darcy mixed convective flow of an incompressible viscous fluid past a porous vertical flat plate in a saturated porous medium  

Energy Technology Data Exchange (ETDEWEB)

The effect of transverse magnetic field parameter (Hartmann number, Ha) Reynolds number (Re) and Prandtl number (Pr) on the mixed convection flow past a semi-infinite vertical porous plate in a non-Darcian porous medium with variable viscosity and porosity, viscous dissipation and fluid-solid thermal conductivity ratio in the presence of plate transpiration (lateral mass flux) is investigated theoretically and numerically using Keller`s implicit finite difference scheme. It is shown that the Harmann number acts as a retarding force and increases the momentum boundary layer thickness, analogous to the flow against a positive pressure gradient, simultaneously decreasing local skin friction (shear stress). The heat transfer rate is however enhanced by the magnetic field (for positive values of the Eckert number) since the fluid is heated and temperature gradients become reduced between the fluid and the plate, with important potential applications ...

1997-01-01

336

Effects of focused-ion-beam irradiation on perpendicular write head performance  

International Nuclear Information System (INIS)

The effects of focused-ion-beam (FIB) irradiation on writer performance were examined on a perpendicular recording system. The entire top pole was irradiated by FIB with ion doses from 0 to 300 pC/#mu#m"2. PW_5_0 and signal to noise ratio (SNR) were characterized using a spin stand before and after FIB irradiation. It was found that there is degradation of PW_5_0 and SNR due to FIB irradiation. At the maximum dose (300 pC/#mu#m"2), PW_5_0 increased by 33 nm (>30%) and SNR decreased by 5 dB (>25%). The degradation was attributed to the physical pole tip recession and the formation of a magnetic dead layer. The thickness of the magnetic dead layer was estimated by analyzing the write spacing loss. Using atomic force microscopy and stage current change monitored during FIB process, it was found that the entire 4-nm protective carbon layer was etched away with a dose of 25 pC/#mu#m"2. This result implies that the ...

2003-05-15

337

Antiferromagnetic exchange in a bis(imido) uranium (V) dimeric complex  

Energy Technology Data Exchange (ETDEWEB)

Magnetic coupling between two or more metal centers is an important facet of d- and f-block transition metal chemistry due to its implications in chemical bonding. With respect to actinide metals, magnetic coupling between polymetallic actinide centers is less well-known. Of the few documented examples, only one bimetallic uranium(V) complex, [(MeC{sub 5}H{sub 4}){sub 2}U]{sub 2}[{mu}-1,4-N{sub 2}C{sub 6}H{sub 4}] (1), has unequivocally demonstrated antiferromagnetic coupling. This complex employs a {pi}-conjugated 1,4-phenylenedimide ligand system which bridges the two f{sup 1}-metal centers and enables antiferromagentic coupling between unpaired f-e1ectrons residing in a {pi}-symmetry orbital. In this communication, we report the synthesis of a dimeric bis(imido) uranium(V) iodide complex and demonstrate with magnetic susceptibility measurements and density functional theory (DFT) calculations that ...

2008-01-01

338

An investigation into flow regimes for two-phase helium flow  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron accelerator at Fermilab incorporates long two-phase helium passages. During magnet design, the generalized flow map of Baker was used to predict homogeneous flow. Longer than expected magnet time constants led to this investigation. The importance of predicting the flow regime has been amplified with the advent of non-horizontal accelerator designs. A test setup was constructed at Fermilab to investigate two-phase helium flow regimes for conditions practical in accelerator designs. The setup consisted of a standard Tevatron satellite refrigerator, subcooling dewar, heater, 35 m long transfer line, and a specialized end box. A knife blade on the midplane of the transfer line diverted the flow from the upper and lower halves of the pipe to separate vessels in the end box. The amount of liquid above and below the plane was measured at various total mass flow rates and liquid percentages. The results show that stratified flow occurs at ...

1987-10-01

339

Comparison and Physical Interpretation of MCNP and TART Neutron and Gamma Monte Carlo Shielding Calculations for a Heavy-Ion ICF System  

Energy Technology Data Exchange (ETDEWEB)

For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a ...

2002-07-01

340

Field driven ferromagnetic phase evolution originating from the domain boundaries in antiferromagnetically coupled perpendicular anitsotropy films  

Energy Technology Data Exchange (ETDEWEB)

Strong perpendicular anisotropy systems consisting of Co/Pt multilayer stacks that are antiferromagnetically coupled via thin Ru or NiO layers have been used as model systems to study the competition between local interlayer exchange and long-range dipolar interactions [1,2]. Magnetic Force Microscopy (MFM) studies of such systems reveal complex magnetic configurations with a mix of antiferromagnetic (AF) and ferromagnetic (FM) phases. However, MFM allows detecting surface stray fields only and can interact strongly with the magnetic structure of the sample, thus altering the original domain configuration of interest [3,4]. In the current study they combine magnetometry and state-of-the-art soft X-ray transmission microscopy (MXTM) to investigate the external field driven FM phase evolution originating from the domain boundaries in such antiferromagnetically ...

2008-05-01

341

H{sup -} ion source using a localized virtual magnetic filter in the plasma electrode: type I LV magnetic filter  

Energy Technology Data Exchange (ETDEWEB)

A new multicusp H{sup -} ion source using a Localized Virtual magnetic filter of type I [Ref.6] in the plasma electrode is investigated. A multipole (MP) arrangement with a spacing of 10 mm of the magnet bars holds an extraction hole, optimizing the efficient production of high H{sup -} current, and at the same time only a small electron component was co-extracted with the H{sup -} ions. The local filter arrangement separates the beam electrons at a low energy. It is shown that the co-extracted total electron current is determined principally by the integrated magnetic field flux (Gcm) of the local filter with an extraction system at a constant extraction voltage. When the value of the Gcm is increased, the total electron component is reduced, while the H{sup -} electrical efficiency had a broad maximum around the optimized value of the Gcm. A thicker plasma electrode should be necessary for sufficient ...

1999-12-01

342

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the ...

2009-03-15

343

Van Der Pol model of a Cerenkov maser  

Energy Technology Data Exchange (ETDEWEB)

A non-linear analysis of a Cerenkov maser is presented. The system consists of a ring configuration of a cylindrical waveguide filled with a dielectric material. A single transverse-magnetic mode is assumed to propagate in the system. A low-density pencil electron beam travels in part of the ring, confined by a strong axial magnetic field. Using the single-particle description for the beam and the wave equation for the field, we obtain a set of two coupled non-linear differential equations describing the slowly varying amplitude and phase of the electromagnetic mode. The gain per path is assumed to be small and the spatial growth of the field is neglected. The resulting time dependent amplitude includes the exponential gain of the linear stage and the saturation to its maximum value. The time dependent frequency is also calculated. The two equations are combined to a single Van Der Pol equation with a ...

1995-12-31

344

Managing system for mounted parts and spare parts of power source facilities  

Energy Technology Data Exchange (ETDEWEB)

The power source facilities of JT-60 consist of poloidal magnetic coil power source, toroidal magnetic coil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual relating and retrieval by making mounted parts and spare parts into a data base and doing their unified management with a ...

1995-07-01

346

Magnetic braking of the rotation of molecular cloud cores  

International Nuclear Information System (INIS)

We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).

347

LHC magnet alignment  

CERN Document Server

Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.

2007-01-01

348

RED NUGGETS AT z #approx# 1.5: COMPACT PASSIVE GALAXIES AND THE FORMATION OF THE KORMENDY RELATION  

International Nuclear Information System (INIS)

We present the results of Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) imaging of a sample of 19 high-mass passively evolving galaxies with 1.2 < z < 2, taken primarily from the Gemini Deep Deep Survey (GDDS). Around 80% of galaxies in our GDDS sample have spectra dominated by stars with ages #approx#>1 Gyr. Our rest-frame R-band images show that most of these objects have compact regular morphologies which follow the classical R "1"/"4 law. These galaxies scatter along a tight sequence in the size versus surface brightness parameter space which defines the Kormendy relation. Around one-third (3/10) of the massive red objects in the GDDS sample are extraordinarily compact, with effective radii under 1 kpc. Our NICMOS observations allow the detection of such systems more robustly than is possible with optical (rest-frame UV) data, and while similar systems have been seen at z #approx#> 2, this is ...

2009-04-10

349

First Light for MIRSI  

Science.gov (United States)

We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This system offers the unique ability to acquire both ...

2001-12-01

350

Density separation of materials by using magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...

1980-03-01

351

Delayed neutron energy spectra following fast fission of "2"3"8U  

International Nuclear Information System (INIS)

Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to 450 keV and Bicron ...

352

/sup 18/O isotope effect in carbon-13 nuclear magnetic resonance spectroscopy. Part 8. Oxygen exchange of 2,4,6-trimethylpyrylium cation  

Energy Technology Data Exchange (ETDEWEB)

The rate of the oxygen-exchange reaction in an aqueous solution of a heterocyclic oxygen compound, 2,4,6-trimethylpyrylium perchlorate, was quantitated. The /sup 18/O isotope effect in /sup 13/C NMR spectroscopy affords a direct, continuous, and relatively simple analysis of the reaction and was used to obtain data on the incorporation of /sup 18/O from solvent H/sub 2//sup 18/O into the pyrylium salt. Due to the low solubility of this salt in aqueous solutions, 2,4,6-trimethyl(2-/sup 13/C)pyrylium perchlorate and 2,4,6-trimethyl(2,6-/sup 13/C/sub 2/)pyrylium perchlorate were synthesized to facilitate the acquisition of the data on an NTC-200 spectrometer operating at 50.31 MHz. Upon incorporation of /sup 18/O into the pyrylium salt, the /sup 13/C NMR signal of the directly bonded carbon atom is shifted upfield 0.038 ppm. A /sup 13/C isotope effect is also detected in the doubly /sup 13/C-enriched pyrylium salt where the /sup 13/C NMR signal for /sup 13/C-O-/sup ...

1984-12-12

353

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best ...

2006-12-21

354

The controlled creation of a maximally entangled state between a SQUID ring and a single electromagnetic field mode  

International Nuclear Information System (INIS)

We consider a SQUID ring inductively coupled to an electromagnetic field mode, both treated quantum mechanically. We demonstrate a method for creating a maximally entangled state between the ring and the field mode. Our method utilises a non-adiabatic external magnetic flux pulse to move into and out of a transition region. Hence, our approach is fundamentally different to techniques based on Landau-Zener tunnelling that can also be used to achieve similar results. Our analysis is extended to include the effects of coupling the system to a dissipative environment. With this model we show that although such an environment makes a noticeable difference to the time evolution of the system, it need not destroy the entanglement of this coupled system over time scales required for quantum technologies.

2010-07-01

355

Molecular dynamics simulation of effect of indenter shape on nanoscratch of Ni  

British Library Electronic Table of Contents (United Kingdom)

Thin films of Ni and Ni alloy have been widely used in microelectromechanical systems (MEMS) and magnetic storage systems. As the dimensions of components in these systems decrease to the micro-scale, even the nano-scale, the interfacial phenomena significantly differ to the counterparts on the macro-scale. A better understanding of micro-/nano-tribology will benefit the fabrication of the small components. In this manuscript parallel molecular dynamics (MD) simulations have been conducted to investigate the nanoscratch behavior of nickel. The simulations are performed for two cases with different indenter shapes. Case I has a sharp indenter, while the indenter in Case II is blunt. It has been found that the indenter shape significantly influences the nanoscratch deformation. The sharp ind...

2009-01-01

356

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron ...

1991-10-02

357

Physical and optical properties of rare earth cobalt magnets  

Energy Technology Data Exchange (ETDEWEB)

Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.

1980-08-01

363

METHOD OF FORMING THIN MAGNETIC FILM  

J-STORE (Japan)

Full Text Available

2007-10-04

369

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

370

Measurement of fission cross sections for nuclear transmutation on Am-241, Am-242m and Am-243 using lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)

1997-12-31

371

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.

1998-08-01

372

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)

1999-02-01

373

Diode laser overtone spectroscopy of CO_2 at 780nm  

International Nuclear Information System (INIS)

Overtone absorption lines of "1"2C"1"6O_2 have been examined by using a tunable diode laser (TDL) spectrometer in the region around 12770cm"-"1. The spectrometer sources are commercially available double heterostructure InGaAlAs TDLs operating in the 'free-running' mode, which allowed the detection of the line positions within 0.01cm"-"1. The observed carbon dioxide absorption lines belong to the #nu#_1+5#nu#_3 ro-vibrational band with rotational quantum number J up to 48. The minimum absorbance detected by the spectrometer (#approx#5x10"-"6) permitted to observe the weakest lines having the absorption cross section of the order of #approx#1x10"-"2"7cm"2/molecule.

2005-12-01

374

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-09-01

375

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

376

NASA TECH BRIEF  

Science.gov (United States)

Magnetic Forming Studies. The use of transient high magnetic-field devices has made possible the generation of very large accurately ...

378

Magnetic properties of single crystalline RE_2PdSi_3 intermetallic compounds  

International Nuclear Information System (INIS)

... susceptibility magnetization magnetoresistance monocrystals order-disorder

379

Finite Element Analysis of Magnetoelastic Plate Problems.  

Science.gov (United States)

... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...

1981-08-01

380

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

381

An investigation of the decoupling effects in a magnetic forming beryllium coil assembly.  

Science.gov (United States)

Decoupling force exerted by magnetic forming Be coil assembly on metallic plate during forming

1968-01-01

383

The calibration of sub-Coulomb heavy ion proton transfer reactions  

Energy Technology Data Exchange (ETDEWEB)

Measurements were made of the cross sections for the /sup 27/Al(/sup 16/O,/sup 15/N)/sup 28/Si, /sup 89/Y(/sup 15/N,/sup 16/O)/sup 88/Sr and /sup 89/Y(/sup 27/Al,/sup 28/Si)/sup 88/Sr reactions at energies near and below the Coulomb barrier. The first reaction required separate measurements of the transfer to elastic cross section ratio for particular charge states, the charge state distribution for /sup 27/Al and /sup 28/Si ions, and the absolute elastic scattering cross section for the /sup 27/Al + /sup 16/O system. The ratio measurement required the combined use of two relatively new scientific instruments: the momentum filter and the Bragg curve spectrometer. The latter two transfer measurements were performed using the same setup involving surface barrier detectors at backward angles. Additional elastic scattering data for the /sup 15/N + /sup 28/Si, /sup 89/Y + /sup 15/N, /sup 89/Sr + /sup 27/Al, and /sup 88/Sr + /sup 28/Si ...

1987-01-01

384

A REAL-TIME COAL CONTENT/ORE GRADE (C2OC) SENSOR  

Energy Technology Data Exchange (ETDEWEB)

This is the final report of a three year DOE funded project titled ''A real-time coal content/ore grade (C{sub 2}OG) sensor''. The sensor, which is based on hyperspectral imaging technology, was designed to give a machine vision assay of ore or coal. Sensors were designed and built at Resonon, Inc., and then deployed at the Stillwater Mining Company core room in southcentral Montana for analyzing platinum/palladium ore and at the Montana Tech Spectroscopy Lab for analyzing coal and other materials. The Stillwater sensor imaged 91' of core and analyzed this data for surface sulfides which are considered to be pathfinder minerals for platinum/palladium at this mine. Our results indicate that the sensor could deliver a relative ore grade provided tool markings and iron oxidation were kept to a minimum. Coal, talc, and titanium sponge samples were also imaged and analyzed for content and grade with promising results. This research has led ...

2005-04-01

385

The effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system  

Energy Technology Data Exchange (ETDEWEB)

The CALPHAD (calculations of phase diagrams) method is used to examine the effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system in the paramagnetic state. The reported susceptibility data for pure Fe is first re-evaluated. The contributions to the total Gibbs energy of the ferrite ({alpha}) and austenite ({gamma}) from the external fields are calculated based on the Curie-Weiss law and the re-evaluated susceptibility data. The Fe-Si phase diagram on the Fe-rich side as a function of applied field is calculated using the Thermo-Calc(TM) package. With increasing field strength, the {gamma} loop shrinks monotonically; that is, the {alpha}/{gamma}-Fe transition temperature increases while that for {gamma}/{delta}-Fe transition decreases, albeit more slowly. Finally, in conformance with the existing CALPHAD databank, Redlich-Kister polynomials are proposed to account for the compositional and temperature ...

2006-07-21

386

Production, transport and injection of a cold non-magnetized electron beam for the recirculating linac  

International Nuclear Information System (INIS)

A new foilless diode with a non-magnetically immersed cathode was recently designed and built for the Sandia Recirculating Linear Accelerator (RLA). Because there is also no radial component of electric field at the cathode, the electron beam starts almost parallel and is matched to a solenoidal transport system with minimum increase in divergence and radius. The electrode emission surface is specified by an area covered with felt which undergoes explosive electron emission at low electrical field stresses (60 kV/cm). The 1.7 MV, 4.8-kA produced beam is transported 1.5 meters to the injection region of the racetrack via a system of solenoids and focusing coils. The maximum transverse velocity component at injection point (1.5 m downstream from the cathode surface) is #beta# perpendicular = 0.03 and the radius r = 2.8 cm which give a quite small beam emittance #epsilon# = 0.08 rad-cm. Three- dimensional numerical simulations ...

1989-06-01

387

New correlated electron physics from new materials  

International Nuclear Information System (INIS)

Many important advances in the physics of strongly correlated electron systems have been driven by the development of new materials: for instance the filled skutterudites MT4X12 (M=alkali metal, alkaline earth, lanthanide, or actinide; T=Fe, Ru, or Os; X=P, As, or Sb), certain lanthanide and actinide intermetallic compounds such as URu2-xRexSi2 and CeTIn5 (T=Co, Rh, or Ir), and layered oxypnictides and related materials. These types of complex multinary d- and f-electron compounds have proven to be a vast reservoir of novel strongly correlated electron ground states and phenomena. In these materials, the occurrence of such a wide range of ground states and phenomena arises from a delicate interplay between competing interactions that can be tuned by partial or complete substitution of one element for another, as well as the application of pressure, and magnetic fields, resulting in rich and complex electronic phase diagrams in the hyperspace of ...

2009-10-15

388

Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)  

International Nuclear Information System (INIS)

Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...

389

Long-term reliability of amorphous alloy wound core distribution transformers  

Energy Technology Data Exchange (ETDEWEB)

In order to verify long-term reliability of amorphous alloy wound core distribution transformers, accelerated aging tests and field trials used by actual transformers were practiced. As for accelerated aging tests, short-circuit tests were added to imitate mechanical stress in operation on a utility's distribution system. As a result, even after the equivalent of 30 years, which was the normal expected transformer's life, magnetic characteristic was unchanged, so these transformers could be operated. Also, about field trials, two hundred transformers of four kinds were installed on a utility's distribution system to look into no-load characteristics. They were equipped with a mechanism to measure load current, background vibration and lightning surge current, so the influence for magnetic characteristic could be inspected. As a result, remarkable change wasn't seen ...

1994-01-01

390

Gyrokinetic particle simulation model  

Energy Technology Data Exchange (ETDEWEB)

A new type of particle simulation model based on the gyrophase-averaged Vlasov and Poisson equations is presented. The reduced system, in which particle gyrations are removed from the equations of motion while the finite Larmor radius effects are still preserved, is most suitable for studying low frequency microinstabilities in magnetized plasmas. It is feasible to simulate an elongated system (L/sub parallel/ >> L/sub perpendicular/) with a three-dimensional grid using the present model without resorting to the usual mode expansion technique, since there is essentially no restriction on the size of ..delta..x/sub parallel/ in a gyrokinetic plasma. The new approach also enables us to further separate the time and spatial scales of the simulation from those associated with global transport through the use of multiple spatial scale expansion. Thus, the model can be a very efficient tool for studying anomalous transport ...

1986-07-01

391

Europium oxynitride ferromagnetic semiconductors  

International Nuclear Information System (INIS)

At room pressure and temperature the system EuOsub(1-x)Nsub(x) has two solid-solubility ranges, each with the NaCl structure: for 0 =< x =< 0.30 the system is ferromagnetic and semiconducting above the Curie temperature; for 0.92 =< x <1 it is metallic. Conductivity and Seebeck voltages indicate intrinsic behaviour above 310 K with an energy gap that decreases with increasing x for 0 =< x =< 0.30. Magnetic susceptibilities are consistent with 4f"6 configurations at x europium ions per molecule and a ferromagnetic Curie temperature Tsub(C) that increases with x. Low-temperature transport measurements were made only for 0.20 =< x =< 0.30: a minimum in the electrical conductivity, approximately 30 K above Tsub(C) correlates well with the onset of an anomalous low-temperature crystal contraction and with deviations from a Curie-Weiss law typical of short-range magnetic order. Below ...

1978-01-01

392

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum control of the radial overlap of the ...

2008-09-01

393

Application of photogrammetry, remote sensing and GIS in the environmental monitoring of the Deutsche Steinkohle AG; Einsatz von Photogrammetrie, Fernerkundung und GIS im Umweltmonitoring der Deutschen Steinkohle AG  

Energy Technology Data Exchange (ETDEWEB)

Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent scatterer technology (here: ...

2006-03-15

394

Spontaneous and stimulated Raman studies of vibrational dephasing in condensed phases  

Energy Technology Data Exchange (ETDEWEB)

Vibrational dephasing in condensed phases is studied from both a theoretical and experimental standpoint. A theory is presented which describes the dynamics of motional or exchange processes in weakly perturbed systems. This general formalism, which has been previously used to describe motional narrowing in magnetic resonance, is applied to vibrational spectroscopy. The model treats the case of a high frequency vibration anharmonically coupled to a low-frequency vibration. Intermolecular exchange of low frequency vibrational quanta results in a temperature dependent broadening and frequency shift of the high frequency vibration. Analysis of experimental data by this model yields both the exchange rates and the anharmonic couplings.

1980-05-01

395

Neutrinos produced by nuclei injected by young pulsars inside compact massive binaries  

Energy Technology Data Exchange (ETDEWEB)

We consider propagation of relativistic heavy nuclei injected by a young pulsar into the radiation field of a massive companion. If the binary system (BS) is compact enough, then the nuclei suffer multiple photodisintegrations in collisions with thermal photons coming from the massive star (MS). Due to the propagation effects of charged particles in the magnetic field of the MS some hadrons can impinge onto the MS surface at large angles. We calculate the fluxes of produced neutrinos as a function of the viewing angle measured from the plane of the BS. It is found that significant fluxes of neutrinos should be also expected in the case of non-eclipsing BSs.

2005-06-15

396

Moderate Deviations for a Curie-Weiss model with dynamical external field  

CERN Document Server

In the present paper we prove moderate deviations for a Curie-Weiss model with external magnetic field generated by a dynamical system, as introduced by Dombry and Guillotin-Plantard. The results extend those already obtained in the case of a constant external field by Eichelsbacher and L\\"owe. The Curie-Weiss model with dynamic external field is related to the so called dynamic Z-random walks. We also prove a moderate deviation result for the dynamic Z-random walk, completing the list of limit theorems for this object.

2011-01-01

397

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

398

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-01-01

399

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1992-10-05

400

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-04-01

401

Coordination compounds of oxovanadium(4), nickel(2) and copper(2) with bis-(salicyliden)-thiocarbazide  

International Nuclear Information System (INIS)

A reaction of aqueous-methanol solutions of thiocarbazide and salycilic aldehyde, taken in a molal ratio of 1:2 on the matrix of oxovanadium(VO) in the presence of aqueous ammonium results in a coordination compound of the VC_1_5H_1_2N_4O_3S composition. Similar compounds are obtained with salts of nickel(2) and copper(2). Complexes of oxovanadium(4) and copper(2) have effective magnetic moments normal for systems with a spin of 1/2. The compound with nickel is diamagnetic. These data agree with the configuration of the coordination compounds obtained.

402

A phenomenological Landau theory for electromagnons in cubic spinel multiferroic CoCr_2O_4  

International Nuclear Information System (INIS)

Non-anisotropic free energy is considered which under minimization yields two magnetic phases: a conical spin density wave and a low temperature conical cycloid. Using equations of motion, the excitation spectrum is studied. Knowing the nature of these excitations, the dielectric function as well as the fluctuation specific heat is computed and compared with the experimental spectrum. Due to the electromagnon going soft, the dielectric function (imaginary part) as well as the specific heat capacity show peaks at the temperature where ferroelectricity appears in the system.

2010-06-09

403

Revisit to the helicity and the generalized self-organization theory  

Energy Technology Data Exchange (ETDEWEB)

It is clarified that the so-caned 'helicity conservation law' is never the conservation equation of the helicity K itself', but is merely 'the time change rate equation of K', which is passively and resultantly determined by the mutually independent volume and surface integral terms. It is shown that since the total helicity K can never be conserved in the real experimental systems, the conjecture of the total helicity invariance is not physically available to real magnetized plasmas in an exact sense. The well-known relaxation theory by Dr. J. B. Taylor is clarified to be neither the variational principle nor the energy principle, but be merely a mathematical calculation, using the variational calculus in order to find the minimum magnetic energy solution from the set of solutions having the same value of K. With the use of auto-correlations for physical quantities, it is ...

2000-09-01

404

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...

2008-02-01

405

A new analysis for membrane noise. The integral spectrum.  

UK PubMed Central (United Kingdom)

A new method of random data analysis has been developed with special implications for membrane noise. The integral spectrometer uses overlapping broad-band filters of simple design, whose bandwidth...Full Text Available

1976-07-01

406

Results from a Bragg Curve Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-01-01

407

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-10-22

408

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

409

Large solid angle Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.

1984-02-01

410

Application of the digital waveform analysis to Bragg curve spectrometer  

International Nuclear Information System (INIS)

Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)

2004-11-01

411

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

412

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

413

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...

2008-04-15

414

Full Spin and Spatial Symmetry Adapted Technique for Correlated Electronic Hamiltonians: Application to an Icosahedral Cluster  

CERN Document Server

While dealing with molecular systems, it is highly advantageous to work with a basis set which has definite total spin and also belongs to a definite irreducible representation of its symmetry (point) group. But unfortunately, there hadn't been any general simple technique to deal with the problem, especially when molecule possesses non-Abelian point group symmetry. In a previous paper \\cite{sahoo}, we presented a general technique which is a hybrid method based on Valence Bond basis and the basis of z-component of the total spin. The technique is applicable to all types of point groups and is easy to implement on computer. We illustrated the power of the method by applying it to a molecular magnetic system. Here we extend the method to electronic systems and demonstrate this extended technique by applying it to a model icosahedral half-filled electronic system (12 sites). Reasons ...

2010-01-01

415

State of the art simulations of magnicon  

International Nuclear Information System (INIS)

The magnicon is a highly attractive candidate to be the RF source for a future multi-Tev linear collider. Physical models and computer codes have been developed which can provide start-to-end self-consistent simulations of a magnicon, including precise simulations of the high-convergence electron gun, RF-system, magnetic system, and beam collector. The 3-D beam dynamics simulations include realistic fields, finite beam size and transverse space charge effects. The codes allow one to provide steady-state simulations of the entire tube, so as to evaluate transient process of magnicon excitation, parasitic mode self-excitation, stability analysis, and tolerance analysis. The results of the simulations are found to be in good agreement with magnicon experiments. A brief description of the physical models and simulation codes employed will be given.

2002-12-12

416

Recent Energy Saving Technologies on Railway Traction Systems  

British Library Electronic Table of Contents (United Kingdom)

Energy saving technologies in the railway vehicle traction field can be mainly categorized into two domains: reducing loss and increasing the regenerative energy. Energy saving technologies for the traction equipment by the use of power converters with less loss and high-efficiency permanent magnet synchronous motors are introduced. The regenerative brake related technologies are also presented as another measure to save the energy, including the improvement of the regenerative brake control and application of energy storage devices. It is concluded that the benefit of the energy saving technology is not only the energy saving itself but also downsizing traction equipments and reducing the maintenance work in the electrical railway system. Copyright Copyright 2010 Institute of Electrical E...

2010-01-01

417

Parallelization of the FLAPW method  

International Nuclear Information System (INIS)

The FLAPW (full-potential linearized-augmented plane-wave) method is one of the most accurate first-principles methods for determining electronic and magnetic properties of crystals and surfaces. Until the present work, the FLAPW method has been limited to systems of less than about one hundred atoms due to a lack of an efficient parallel implementation to exploit the power and memory of parallel computers. In this work we present an efficient parallelization of the method by division among the processors of the plane-wave components for each state. The code is also optimized for RISC (reduced instruction set computer) architectures, such as those found on most parallel computers, making full use of BLAS (basic linear algebra subprograms) wherever possible. Scaling results are presented for systems of up to 686 silicon atoms and 343 palladium atoms per unit cell, running on up to 512 processors on a CRAY T3E parallel ...

1999-12-01

418

Modeling of an Inductive Adder Kicker Pulser for a Proton Radiography System  

Energy Technology Data Exchange (ETDEWEB)

An all solid-state kicker pulser for a proton radiography system has been designed. Multiple solid-state modulators stacked in an inductive-adder configuration are utilized in this kicker pulser design. Each modulator is comprised of multiple metal-oxide-semiconductor field-effect transistors (MOSFETs) which quickly switch the energy storage capacitors across a magnetic induction core. Metglas is used as the core material to minimize loss. Voltage from each modulator is inductively added by a voltage summing stalk. A circuit model of a prototype inductive adder kicker pulser modulator has been developed to predict the performance of the pulser modulator. The modeling results are compared with experimental data.

2001-06-12

419

Effect of weak dissipation on a drift orbit mapping  

Energy Technology Data Exchange (ETDEWEB)

The effect of weak dissipation on drift orbits has been investigated making use of a simple mapping model in a helical magnetic field. It is found that, after many mapping iterations, any orbit tends to an attractor forming a vortex line even with very small dissipation. The convergence is faster for larger dissipation, i.e., the number of iteration N to converge within a certain distance from the attractor is inversely proportional to the amount of the dissipation. Although the behavior of orbits completely change, the basic stability characteristics of the system does not change, i.e, the coordinate of the attractors are determined by the stable fixed points in the area preserving system because the dissipation is very small. Since wide range of orbits are concentrated around the attractors after many toroidal circulations, a pinch effect is created by a small dissipation. Application of this pinch effect to fusion ...

2000-03-01

420

Magnetic fluctuation measurement in Sino United Spherical Tokamak plasma  

International Nuclear Information System (INIS)

To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)

2007-07-01

421

[Fast neutron cross section measurements]. Progress report  

Energy Technology Data Exchange (ETDEWEB)

In this report, we outline the progress achieved in two distinct under the DOE-sponsored cross section project: the initial results obtained from the pulsed 14 MeV neutron facility, and a cooperative effort with Argonne National Laboratory in the measurement of fast neutron cross sections in yttrium. In the 14 MeV neutron laboratory, this year has seen the maturation of the project into one in which initial scattering measurements are now underway. We have improved the accelerator and ion source in several significant ways, so that neutron intensities have now been proven to be adequate for our series of elastic scattering angular distribution measurements outlined in our initial proposal of two years ago. We have successfully tested all components of the time-of-flight spectrometer and recorded initial neutron spectra from the ring targets that we have obtained for our first angular distribution measurements. Examples of the time-of-flight spectra that have been ...

1991-12-31

422

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...

2006-03-15

423

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

International Nuclear Information System (INIS)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are collected with a ...

2006-03-01

424

Automated ARXPS goniometer/diffractometer. Final report, April 1995--March 1997  

Energy Technology Data Exchange (ETDEWEB)

This award provided for an automated computer-controlled goniometer/diffractometer/manipulator with hot and cold stages and data acquisition system that was interfaced with the high resolution Scienta ESCA-300 X-ray photoelectron spectrometer at Lehigh University. The automation allows angular dependent X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS) data to be accurately and rapidly collected without the very time-consuming and labor-intensive manual method that was previously required. It also provides for automated multi-sample analyses, collecting both wide survey scans and selected binding energy range analyses, with complete computer control and data storage. This allows 24 hour data collection without requiring the continuous presence of operators. The overall result is a greater productivity for the XPS laboratory, approximately doubling the output of the laboratory. While the automated ...

1998-07-01

425

Vacuum arc ignition by penning discharge in a strong magnetic field  

Energy Technology Data Exchange (ETDEWEB)

Vacuum arc with cathode spots on the cold electrode is widely used as a plasma generator in a such kind of devices like metal ion sources, plasma cathode electron guns, thing films deposition facilities and others. Most vacuum arc devices utilize a high voltage discharge across an insulator surface to provide a trigger plasma which in turn initiates the main arc discharge. Operation of vacuum arc in a repetitively pulsed mode required a stable triggering system for the long time. But with a discharge across the insulators the number of stable pulses is limited by 100,000 or little bit more. The better method for vacuum arc ignition is low pressure discharge. As shown in this paper it is possible to increase the lifetime of the ignition system in 10 times at least, but negative characteristic of this system is a relatively high pressure (about 0.1 mtorr). In some kinds of vacuum arc applications it is impermissible because ...

1995-12-31

426

Transverse and longitudinal excitation modes in interacting multispin systems  

International Nuclear Information System (INIS)

Magnetic excitation in coupled multispin system is studied theoretically focusing on Cu_2Fe_2Ge_4O_1_3 and Cu_2CdB_2O_6 as typical examples of such system. These compounds consist of spin dimer and spin monomer parts and show an antiferromagnetic phase transition at low temperatures due to the spin monomer part. A multispin containing a spin dimer and spin monomers is treated as a basis unit. The multispin forms a spin multiplet and its energy levels are separated into high and low regions reflecting the characteristic energies of the dimer and monomer parts. We regard the system as interacting multispins and apply an extended Holstein-Primakoff theory by introducing bosons for each energy level of a spin multiplet. In the low-energy region, the obtained magnon dispersion and dynamical spin correlation function agree quantitatively with experimental results of inelastic neutron scattering performed in ...

2010-08-01

427

Beam direct converter with varying magnetic field  

Energy Technology Data Exchange (ETDEWEB)

The concept of a direct energy recovery system that applies a varying magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. The output beam energy and power of such an NNB will be {approximately}1 MeV and {approximately}1- MW/beam-line, respectively, and nearly the same amounts of positive- and negative-ion beams remain unneutralized in an NNB by using a gas-neutralizing cell. Therefore, the output of a beam direct convertor in an NNB is a bipolar direct current (dc) electric power with close to {plus_minus} 1 MV and several amperes if a conventional electrostatic or magnetostatic field is applied for ion beam separation. However, such high-voltage dc power is difficult to handle at the point of the regeneration of the power back to a commercial electric line because a very high voltage inverter tough enough to withstand ...

1994-12-01

428

Transformation of the ATOMKI-ECRIS into a Plasma Device  

International Nuclear Information System (INIS)

Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check ...

2006-01-01

429

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...

1999-04-01

430

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously produced to meet ...

1999-12-01

431

Recent trends in heavy-fermion physics  

Energy Technology Data Exchange (ETDEWEB)

We discuss recent results obtained for the heavy-fermion metals UPd{sub 2}Al{sub 3} and YbRh{sub 2}Si{sub 2}. UPd{sub 2}Al{sub 3} is the first among all superconductors for which tunneling and inelastic neutron-scattering data highlight a non-phononic, i.e., magnetic-exciton mediated, pair state. YbRh{sub 2}Si{sub 2} represents a model system exhibiting pronounced non-Fermi liquid effects above a weak antiferromagnetic phase transition at T{sub N}=70 mK. Upon approaching the quantum critical point (T{sub N}{yields}0), by low doping with Ge, one observes for T<0.3 K disparate behavior in the temperature dependences of both the electrical resistivity and the electronic specific heat as well as a Curie-Weiss law in the uniform magnetic susceptibility, implying uncompensated large 4f moments. These observations indicate a break up of the composite quasiparticles into their local f-spin and itinerant conduction-electron ...

2003-05-01

432

Observation of the limit cycle in the asymmetric plasma divided by the magnetic filter  

Energy Technology Data Exchange (ETDEWEB)

Asymmetric plasma divided by the magnetic filter (MF) is numerically simulated by the one-dimensional particle-in-cell code VSIM1D. Depending on the asymmetry, the system behaves static or dynamic. In the static state, the potentials of the main plasma and the sub-plasma are given by the sheath potentials, {phi}{sub M} - 3T{sub Me}/e and {phi}{sub S} - 3T{sub Se}/e, respectively, with e being an electron charge and T{sub Me} and T{sub Se} being electron temperatures (T{sub Me} > T{sub Se}). In the dynamics state, while {phi}{sub M} - 3T{sub Me}/e, {phi}{sub S} oscillates periodically between {phi}{sub S,min} - 3T{sub Se}/e and {phi}{sub S,max} - 3T{sub Me}/e. The ions accelerated by the time varying potential gap get into the sub-plasma and excite the laminar shock waves. This periodic phenomenon can be understood as a limit cycle due to transitions between two bifurcated states of {phi}{sub S,min} and {phi}{sub S,max}. (author)

2000-08-01

433

High Magnetic Field NMR Studies of LiVGe$_2$O$_6$, a quasi 1-D Spin $S = 1$ System  

CERN Document Server

We report $^{7}$Li pulsed NMR measurements in polycrystalline and single crystal samples of the quasi one-dimensional S=1 antiferromagnet LiVGe$_2$O$_6$, whose AF transition temperature is $T_{\\text{N}}\\simeq 24.5$ K. The field ($B_0$) and temperature ($T$) ranges covered were 9-44.5 T and 1.7-300 K respectively. The measurements included NMR spectra, the spin-lattice relaxation rate ($T_1^{-1}$), and the spin-phase relaxation rate ($T_2^{-1}$), often as a function of the orientation of the field relative to the crystal axes. The spectra indicate an AF magnetic structure consistent with that obtained from neutron diffraction measurements, but with the moments aligned parallel to the c-axis. The spectra also provide the $T$-dependence of the AF order parameter and show that the transition is either second order or weakly first order. Both the spectra and the $T_1^{-1}$ data show that $B_0$ has at most a small effect on the alignment of the AF moment. There is no ...

2001-01-01

434

Development of large-capacity refrigeration at 1.8 K for the Large Hadron Collider at CERN  

CERN Document Server

CERN, the European Laboratory for Particle Physics, is working towards the construction of the Large Hadron Collider (LHC), a high-energy, high-luminosity particle accelerator and collider [1] of 26.7 km circumference, due to start producing frontier physics, by bringing into collision intense proton and ion beams with centre-of-mass energies in the TeV-per-constituent range, at the beginning of the next century. The key technology for achieving this ambitious scientific goal at economically acceptable cost is the use of high-field superconducting magnets using Nb-Ti conductor operating in superfluid helium [2]. To maintain the some 25 km of bending and focusing magnets at their operating temperature of 1.9 K, the LHC cryogenic system will have to produce an unprecedented total refrigeration capacity of about 20 kW at 1.8 K, in eight cryogenic plants distributed around the machine circumference [3]. This has requested the ...

1996-01-01

435

Crystal structure and magnetic properties of Sm{sub 3}ReO{sub 7}  

Energy Technology Data Exchange (ETDEWEB)

Crystals of a new ternary samarium rhenium oxide, Sm{sub 3}ReO{sub 7} were obtained by subsolidus reaction of samariumsesquioxide and rheniumdioxide (ratio 1.5:1) in sealed Pt-10Rh-tubes at 1673 K. The structure was determined by single-crystal X-ray diffraction. Sm{sub 3}ReO{sub 7} crystallizes in the orthorohombic system with unit cell dimensions a = 10.736(5), b = 7.392(3), and c = 7.519(3) in space group Cmcm (No. 63) with Z = 4. The structure consists of ReO{sub 6} octahedra, distorted SmO{sub 6} octahedra, and SmO{sub 8} prisms that are interconnected to each other to form a three-dimensional network. Rhenium has the formal oxidation state of +5 but no metal-metal bond is observed in this compound. The observed magnetization in the temperature range 4 K < T < 52 K is explained by a Curie-Weiss law modified by a temperature independent Van Vleck paramagnetism of samarium (3+).

1996-08-01

436

A surface acoustic wave electric field strength meter for environmental studies of HV transmission lines  

International Nuclear Information System (INIS)

In recent years, there has been a significant increase in concern over the health and safety aspects of high voltage transmission lines (HVTL). The majority of research has focused on effects directly or indirectly involved with the central nervous system, including physiological, ultrastructural, and biochemical alterations, changes in blood composition, behaviour, reproduction, and development. Several recent epidemiological reports have presented preliminary data suggesting an increase in the incidence of cancer among children and adults exposed to magnetic fields through living close to various types of electrical power lines or devices. With the increase in environmental concerns there has been a concomitant consideration of biological effects and health implications related to presently existing HVTL and those planned in the future. It was concluded that the electric and magnetic field strengths and the electrical ...

1988-04-01

437

A Study on the Matching between the Straight Wing Non-articulated Vertical Axis Wind Turbine and the New Wind Turbine Generator  

Science.gov (United States)

In the current wind turbine generation system, there are substantial problems such as the maximum power of the wind turbine cannot be obtained under the fluctuating wind speed, high in cost and low in annual net electricity production (due to mismatch between a generator and a wind turbine). A new wind turbine generator optimized for the wind turbine output is presented in order to solve such problems. This wind turbine generator consists of a permanent magnet generator, a reactor and a rectifier, and uses neither a control circuit which requires standby electricity nor a PWM converter having a switching element. By selecting most appropriate combination of the permanent magnet generator having multiple windings and the reactor connected in series with each winding, the maximum output of the wind turbine can be obtained without using a control circuit. The new wind turbine generator was directly coupled with the straight ...

2008-01-01

438

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

439

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

440

Magnetic properties of materials  

Energy Technology Data Exchange (ETDEWEB)

A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)

2000-08-15

441

Magnetic flocculation and filtration  

Energy Technology Data Exchange (ETDEWEB)

A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.

1996-10-01

442

Performance of distance relays in a 150 kV grid in case of cross-country faults. Gedrag van distantiebeveiligingen in een 150 kV-net bij cross-country fouten  

Energy Technology Data Exchange (ETDEWEB)

In the 150 kV power system of the Dutch energy utility MEGA Limburg cross-country faults have caused problems in the protection of high voltage transmission lines. A cross-country fault is the simultaneous presence of two single-phase earth connections in different phases and places within the grid. These cross-country faults can lead to the incorrect operation of a number of distance relays, which could result in the faulty disconnection of high voltage transmission lines. To gain an insight into these problems, the transient phenomenon in the power system during cross-country faults were studied. For this purpose, the simulation program EMTP (ElectroMagnetic Transients Program) has been used. Simulation models of the 150 kV power system and the measuring system of a distance relay were developed within EMTP. 7 figs., 1 ill.

1994-11-01

443

Paul Trap Simulator Experiment to Model Intense Beam Propagation in Alternating-gradient Transport Systems  

Energy Technology Data Exchange (ETDEWEB)

The results presented here demonstrate that the Paul Trap Simulator Experiment (PTSX) simulates the propagation of intense charged particle beams over distances of many kilometers through magnetic alternating-gradient (AG) transport systems by making use of the similarity between the transverse dynamics of particles in the two systems. Plasmas have been trapped that correspond to normalized intensity parameters s = wp2 (0)/2wq2 * 0.8, where wp(r) is the plasmas frequency and wq is the average transverse focusing frequency in the smooth-focusing approximation. The measured root-mean-squared (RMS) radius of the beam is consistent with a model, equally applicable to both PTSX and AG systems that balances the average inward confining force against the outward pressure-gradient and space-charge forces. The PTSX device confines one-component cesium ion plasmas for hundreds of milliseconds, which is equivalent ...

2004-01-29

444

NATIONAL HIGH MAGENTIC FIELD LABORATORY FEL INJECTOR DESIGN CONSIDERATION  

Energy Technology Data Exchange (ETDEWEB)

A Numerical study of beam dynamics was performed for two injector systems for the proposed National High Magnetic Field Laboratory at the Florida State University (FSU) Free Electron Laser (FEL) facility. The first considered a system consisting of a thermionic DC gun, two buncher cavities operated at 260 MHz and 1.3 GHz and two TESLA type cavities, and is very similar to the injector of the ELBE Radiation Source. The second system we studied uses a DC photogun (a copy of JLab FEL electron gun), one buncher cavity operated at 1.3 GHz and two TESLA type cavities. The study is based on PARMELA simulations and takes into account operational experience of both the JLab FEL and the Radiation Source ELBE. The simulations predict the second system will have a much smaller longitudinal emittance. For this reason the DC photo gun based injector is preferred for the proposed FSU FEL facility.

2007-06-25

445

Extremely low frequency electric and magnetic fields and cancer: A literature review  

Energy Technology Data Exchange (ETDEWEB)

Epidemiologic studies suggest a weak link between occupational or residential exposure to extremely low frequency electromagnetic fields and cancer, especially tumors of the central nervous and hematopoietic systems. This report discusses these studies with reference to basic research on ELF EMF bioeffects relevant to cancer-promoting mechanisms. Many of the studies suggest a possible interaction of ELF EMF with the immune system, endocrine system, or growth-regulatory signals and morphogenic movements that involve calcium flux through cell membranes. Many bioeffects have been reported only with certain specific combinations of frequency, amplitude, and orientation of the EMF signal with respect to the geomagnetic field. The possibility of signal-specific effects raises a complication in dosimetry for both epidemiologic and experimental studies since ELF EMF effects may not be directly related to field strength. The report ...

1989-12-01

446

Diagnosing mechanical changes: A test of the machine condition monitoring concept  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro recently conducted a demonstration test of a bearing condition monitor. The test, at the 529-MW Kootenay Canal project, proved the ability of the monitor to detect machine condition faults. The capability to detect changing conditions during normal operation of hydroelectric machines gives hydro plant owners the opportunity to anticipate needed maintenance and ultimately to reduce the number of equipment failures. BC Hydro intends to install bearing condition monitors, as well as windings monitors, brushgear monitors, environmental monitors, and other selected systems in as many as 46 of its hydro generators. BC Hydro analyzed forced outages between 1985 and 1989 in its hydro system to identify which parts of a generating unit resulted in the highest number of hours of outage. From there, the utility has formulated a concept for a machine condition monitoring system. To keep the system cost ...

1993-05-01

447

Temperature-dependent properties of semiconductor quantum dots in coherent regime; Temperaturabhaengige Eigenschaften einzelner Halbleiter-Quantenpunkte im Kohaerenten Regime  

Energy Technology Data Exchange (ETDEWEB)

Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). ...

2009-10-15

448

The effective longitudinal dielectric constant for plasmas in inhomogeneous magnetic fields  

Scientific Electronic Library Online (English)

Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.

2004-09-01

449

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

450

Active magnetic regenerator  

Energy Technology Data Exchange (ETDEWEB)

The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.

1982-01-01

451

Optimal capacity of the battery energy storage system in a power system  

Energy Technology Data Exchange (ETDEWEB)

Due to the cyclical human life, utility loads appear to be cyclical too. During daytime when most factories are in operation, the electricity demand is very high. On the contrary, when most people are sleeping from midnight to daybreak, the electric load is very low, usually only half of the peak load amount. To meet this large gap between peak load and light load, utilities must idle many generation plants during light load period while operating all generation plants during peak load period no matter how expensive they are. This low utilization factor of generation plants and uneconomical operation have sparked utilities to invest in energy storage devices such as pumped storage plants, compressed air energy storage plants, battery energy storage systems (BES) and superconducting magnetic energy storage systems (SMES) etc. Among these, pumped storage is already commercialized and is the most widely used device. However, ...

1993-12-01

452

Nanocrystalline permanent magnets with enhanced properties  

International Nuclear Information System (INIS)

Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

2001-09-23

453

Untitled - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...

454

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be ...

2009-10-19

455

Possible observation of the coexistence of superconductivity and long-range magnetic order in NdRh_4B_4  

International Nuclear Information System (INIS)

The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).

1979-01-01

456

PLASMA JET WELDING, COATING, AND CUTTING: AN ...  

Science.gov (United States)

... 31. New electric forming methods offer potentials for light metals; magnetic forming and plasma forming. ... 3, 25 Magnetic Forming ..... ...

1963-02-01

457

Mechanism of viscosity effect on magnetic island rotation  

Energy Technology Data Exchange (ETDEWEB)

It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)

2000-04-01

458

Magnetic Properties of Ni Nanoparticles Embedded in ...  

Science.gov (United States)

... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...

2011-05-14

459

Localization of small magnets against a noisy background  

Science.gov (United States)

Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.

2001-05-01

460

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...

2005-02-01

461
462

Evaluation of Commercial Magnetic Descalers.  

Science.gov (United States)

With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...

1984-01-01

463

Develop Magnetic Coil Design and Manufacturing Capability.  

Science.gov (United States)

... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...

1974-11-01

464

CONTRACT: NAS 8-11811 DESIGN, DEVELOPMENT, MANUFACTURE, AND ...  

Science.gov (United States)

has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magnetic coil is placed over a thin aluminum ...

465

Application of the grazing angle polarized neutron reflectometry to study the magnetism in thin films and stratified media  

Energy Technology Data Exchange (ETDEWEB)

From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...

1992-12-01

466

Anisotropic forming of magnetic powders mixed with ultraviolet resin; Shigaisen koka jushi wo mochiita jisei funmatsu no haiko seikei  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...

1999-01-15

467

An Advance in Superconducting Magnet Technology Opens the Door...  

Science.gov (United States)

magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...

2011-08-20

468

Nonaqueous synthesis of metal oxide nanoparticles: Short review and doped titanium dioxide as case study for the preparation of transition metal-doped oxide nanoparticles  

Science.gov (United States)

The liquid-phase synthesis of metal oxide nanoparticles in organic solvents under exclusion of water is nowadays a well-established alternative to aqueous sol-gel chemistry. In this article, we highlight some of the advantages of these routes based on selected examples. The first part reviews some recent developments in the synthesis of ternary metal oxide nanoparticles by surfactant-free nonaqueous sol-gel routes, followed by the discussion of the morphology-controlled synthesis of lanthanum hydroxide nanoparticles, and the presentation of structural peculiarities of manganese oxide nanoparticles with an ordered Mn vacancy superstructure. These examples show that nonaqueous systems, on the one hand, allow the preparation of compositionally complex oxides, and, on the other hand, make use of the organic components (initially present or formed in situ) in the reaction mixture to tailor the morphology. Furthermore, obviously even the crystal structure can differ from ...

2008-07-15

469

Magnetic properties of Ni/sub 100-2x/Mn/sub x/Sb/sub x/-alloys (5less than or equal toxless than or equal to50) - solid and liquid state  

Energy Technology Data Exchange (ETDEWEB)

Magnetothermal measurements up to 1600 K have been made on alloys in the ternary Ni-Mn-Sb system with a constant ratio Mn/Sb=1/1, to which belong the two ferromagnetic Heusler phases Ni/sub 2/MnSb with L2/sub 1/ structure and NiMnSb with C1/sub b/ structure. The susceptibility-temperature curves show the constitution of the vertical section. At high temperatures the susceptibilities obey a Curie-Weiss law. In the solid state the effective magneton number decreases with increasing Mn concentration from 4.9 (Ni/sub 2/MnSb) to 3.8 (NiMnSb). Simultaneously, on the transition from Ni/sub 2/MnSb to NiMnSb there is a strong increase of the susceptibility and of the Curie temperature from 292 to 686 K. In the heterogeneous range between 10 and 20 at.% Mn another phase part appears which is ferromagnetic at room temperature. By a heat treatment it undergoes a distinct development. In the liquid phase, the alloys can be characterized by an extended Curie-Weiss law. Between ...

1989-02-01

470

Liquid-metal flow in a sharp elbow in a uniform transverse magnetic field  

Science.gov (United States)

In the self-cooling blankets of the Tokamak fusion reactor, a liquid metal, namely liquid lithium, is pumped through a system of ducts to transfer heat and capture neutrons. One of the blanket designs proposed in Argonne National Laboratory's Blanket Comparison and Selection study uses a combination of poloidal and toroidal ducts in order to maximize heat transfer while minimizing net pressure drop. In the design, the poloidal and toroidal ducts meet at sharp, abrupt corners. They were modelled as two identical, straight, semi-infinite, thin-walled, rectangular ducts with 45{degree} miters and joined at a 90{degree} angle in the plane of a strong, uniform magnetic field. While in the toroidal containment vessel (i.e. the blanket), the liquid lithium is subjected to a large electromagnetic body force due to the presence of a strong magnetic field. This body force so dominates the flow as to make the inertial and ...

1989-01-01

471

Feasibility study of iron mineral separation from red mud by high gradient superconducting magnetic separation  

International Nuclear Information System (INIS)

Research highlights: #-># Red mud residues (RM) were disposed in alumina production. #-># Utilization of Red mud residues was affected by its iron content. #-># Superconducting magnetic separation (HGSMS) was used in iron separation from RM. #-># RM with high and low iron contents were separated in HGSMS. - Abstract: The disposal of bayer red mud tailings now seriously threats the environment safety. Reduction and recycling of red mud is now an urgent work in aluminum industry. High gradient superconducting magnetic separation (HGSMS) system was applied to separate the extreme fine RM particles (<100 #mu#m) into high iron content part and low iron content part. Two sorts of RM were fed in the HGSMS. The iron oxide contents in concentrates were about 65% and 45% when RM 1 and RM 2 were fed respectively. Meanwhile, the residues contained 52.0% or 14.1% iron oxide in residues after eight separation stages when ...

2011-02-01

472

Visualization and volumetric structures from MR images of the brain  

Energy Technology Data Exchange (ETDEWEB)

Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows ...

1994-03-01

473

The market potential for SMES in electric utility applications. Final report  

Energy Technology Data Exchange (ETDEWEB)

Superconducting magnetic energy storage (SMES) is an emerging technology with features that are potentially attractive in electric utility applications. This study evaluates the potential for SMES technology in the generation, transmission, distribution, and use of electric energy; the time frame of the assessment is through the year 2030. Comparisons are made with other technology options, including both commercially available and advanced systems such as various peaking generation technologies, transmission stability improvement technologies, and power quality enhancement devices. The methodology used for this study focused on the needs of the market place, the capabilities of S and the characteristics of the competing technologies. There is widespread interest within utilities for the development of SMES technology, but there is no general consensus regarding the most attractive size. Considerable uncertainty exists regarding the eventual ...

1994-06-01

474

Materials needs for compact fusion reactors  

Energy Technology Data Exchange (ETDEWEB)

The economic prospects for magnetic fusion energy can be dramatically improved if for the same total power output the fusion neutron first-wall (FW) loading and the system power density can be increased by factors of 3 to 5 and 10 to 30, respectively. A number of compact fusion reactor embodiments have been proposed, all of which would operate with increased FW loadings, would use thin (0.5 to 0.6 m) blankets, and would confine quasi-steady-state plasma with resistive, water-cooled copper or aluminum coils. Increased system power density (5 to 15 MWt/m/sup 3/ versus 0.3 to 0.5 MW/m/sup 3/), considerably reduced physical size of the fusion power core (FPC), and appreciably reduced economic leverage exerted by the FPC and associated physics result. The unique materials requirements anticipated for these compact reactors are outlined against the well documented backdrop provided by similar needs for the mainline approaches. ...

1983-01-01

475

Large area electron beam pumped krypton fluoride laser amplifier  

International Nuclear Information System (INIS)

Nike is a recently completed multi-kilojoule krypton fluoride (KrF) laser that has been built to study the physics of direct drive inertial confinement fusion. This paper describes in detail both the pulsed power and optical performance of the largest amplifier in the Nike laser, the 60 cm amplifier. This is a double pass, double sided, electron beam-pumped system that amplifies the laser beam from an input of 50 J to an output of up to 5 kJ. It has an optical aperture of 60 cm x 60 cm and a gain length of 200 cm. The two electron beams are 60 cm high x 200 cm wide, have a voltage of 640 kV, a current of 540 kA, and a flat top power pulse duration of 250 ns. A 2 kG magnetic field is used to guide the beams and prevent self-pinching. Each electron beam is produced by its own Marx/pulse forming line system. The amplifier has been fully integrated into the Nike system and is used on a daily basis for ...

476

Corrosion kinetics and magnetite growth on carbon steels during hot conditioning of primary heat transport systems of PHWRs - a metallurgical analysis  

International Nuclear Information System (INIS)

The adherent magnetite film thickness, corrosion rate and the loose crud on the surface of carbon steel and other structural materials were evaluated by inserting the coupons in the two autoclaves connected to the two ends of the PHT systems of Indian PHWRs. This paper includes an analysis of the results obtained during the hot conditioning of TAPP-3 and 4, Kaiga-3 and 4, and RAPP-5. The system temperatures of 230 deg C to 260 deg C and the adherent magnetic thickness of 0.30 ?m to 0.75 ?m on the internal surface of carbon steel were achieved during the hot conditioning of these reactors. The time duration of termination of the hot conditioning ranged from 48 to 71 hours. The maximum magnetite film thickness of 0.75 ?m in 71 hours and temperature 260 deg C and a minimum thickness of 0.30 nm in 48 hours at 230 deg C were achieved during hot conditionings. The XRD analyses of hot conditioned carbon steel coupons showed that ...

2008-12-01

477

Construction and Calibration of the Laser Alignment System for the CMS Tracker  

CERN Document Server

The CMS detector (Compact Muon Solenoid) is under construction at one of the four proton-proton interaction points of the LHC (Large Hadron Collider) at CERN, the European Organization for Nuclear Research (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 m and a length of 5.4 m representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 m2 to detect charged particles from proton collisions. They are placed on a rigid carbon fibre structure, providing stability within the working conditions of a 4 T solenoid magnetic field at ?10oC. Knowledge of the position of the silicon detectors at the level of 100 ?m is needed for an efficient pattern recognition of charged particle tracks. Metrology methods are used to survey tracker subdetectors and the integrated Laser Alignment System (LAS) ...

2006-01-01

478

Launching proton-dominated jets from accreting Kerr black holes: the case of M87  

Science.gov (United States)

A general relativistic model for the formation and acceleration of lowmass-loaded jets from systems containing accreting black holes is presented. The model is based on previous numerical results and theoretical studies in the Newtonian regime, but modified to include the effects of space-time curvature in the vicinity of the event horizon of a spinning black hole. It is argued that the boundary layer between the Keplerian accretion disk and the event horizon is best suited for the formation and acceleration of the accretion-powered jets in active galactic nuclei and micro-quasars. The model presented here is based on matching the solutions of three different regions: i- a weakly magnetized Keplerian accretion disk in the outer part, where the transport of angular momentum is mediated through the magentorotational instability, ii- a strongly magnetized, advection-dominated and turbulent-free boundary layer (BL) between the ...

2011-07-01

479

Selection study of self actuated shutdown system for a large scale FBR  

International Nuclear Information System (INIS)

The Self Actuated Shutdown System (SASS) is now under development for use in a large scale FBR, in order to establish the passive shutdown capability against the postulated ATWS events, i.e. ULOF, UTOP and ULOHS. The function of SASS makes use of the safety characteristics of a liquid metal cooled FBRs such as a large subcooling and low pressure system. The insertion of the control rods insertion is assured even in the most conservative seismic design condition by employing articulate rods and the SASS will be installed into the detaching mechanism employing a curie point the magnet alloy. ULOF analysis of the present FBR shows that coolant boiling inception is prevented if a control rod of the SASS is detached at the uppermost temperature of 680degC for the Curie point magnet, and after the reactor shutdown the coolant temperature is kept below 600degC by the pony motor flow. Therefore the SASS will ...

1995-04-23

480

Half-Heusler phase related structural perturbations near stoichiometric composition FeZnSb  

International Nuclear Information System (INIS)

Half-Heusler phases XYZ (Pearson symbol cF12) are chemically versatile and rich in physical properties. The half-Heusler phase in the Fe-Zn-Sb ternary system was reported in the year 2000. In this work, two new ternary phases are identified in the vicinity of the equiatomic composition FeZnSb in the same system: Fe1-xZnSb (tetragonal, space group P4/nmm, Pearson symbol tP6-?, Z=2: a=4.1113(6) A, c=6.0127(12) A for x=0.08 (1), and a=4.1274(6) A, c=6.0068(12) A for x=0.12 (2)); and Fe7.87Zn6.72Sb8 (Fe0.98Zn0.84Sb) (3) (cubic, space group Fm-3m, Pearson symbol cF96-?, Z=4, a=11.690(13) A). 1 and 2 crystallize in the PbFCl-type structure, and 3 adopts a unique 2x2x2 supercell of a normal half-Heusler structure. The structures of both the tetragonal and cubic phases can be described as assemblies of half-Heusler structure related subunits. Electrical resistivity measurement on the pure sample of 2 shows it has metallic-like behavior, and its thermal ...

2011-05-01

481

Weld integrity of the superconducting cable aluminium jackets of W7-X  

British Library Electronic Table of Contents (United Kingdom)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fur Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The ...

2009-01-01

482

Substitution of neodymium in the Formula Not Shown superconductor  

British Library Electronic Table of Contents (United Kingdom)

The Fe-based copper oxide Formula Not Shown exhibits superconductivity around 50K only when it is properly annealed in Formula Not Shown atmosphere and subsequently in Formula Not Shown atmosphere. In contract Formula Not Shown does not exhibit superconductivity even if it is annealed along the same process as Formula Not Shown . We have synthesized the polycrystalline samples of Formula Not Shown solid solution system Formula Not Shown to investigate the Nd substitution effects. DC magnetization measurements have shown that, the samples in a range of Formula Not Shown exhibit superconductivity and Formula Not Shown was reduced with increasing the Nd content. However, we could not observe the superconductivity for Formula Not Shown and 1. Rietveld refinement results revealed that due to th...

2008-01-01

483

Study on cell nucleation behavior of HDPE?wood composites/supercritical CO2 solution based on rheological properties  

British Library Electronic Table of Contents (United Kingdom)

In this study, the shear viscosities of wood?plastic composites (WPC)/supercritical CO2 (sc-CO2) solutions at different die temperatures and sc-CO2 contents were measured by a slit die attached on a single-screw extrusion system. A theoretical model based on the Carreau-Yasuda model and Arrhenius equation was then developed to describe the shear-thinning behavior of the WPC/sc-CO2 solution. This model was incorporated into a finite element method software, POLYFLOW, to simulate the pressure and velocity field of WPC/sc-CO2 solution flowing through a foaming die. Based on the simulation results, the pressure drop rate and the location of the supersaturation point were estimated to investigate the cell nucleation. The saturation pressure of sc-CO2 in WPC was determined by a magnetic suspensi...

2011-01-01

484

Stabilizing effect of the electron-beam self-fields on the phase-space trajectory in a self-amplified spontaneous emission free-electron laser operating in ultraviolet and x-ray spectral ranges  

International Nuclear Information System (INIS)

A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction ...

2004-02-28

485

Some preliminary views of plasma interaction: electromagnetic-launch systems  

Energy Technology Data Exchange (ETDEWEB)

This discussion outlines a few areas of fundamental research which appear vital for progress in developing advanced propulsion concepts using dc railgun thrusters. We have placed emphasis on the following: (1) dense plasma and high current density influences on changes in microstructure and properties of conventional rail conductors such as Cu, Al, and W alloys or composites; (2) the influences described in (1) on more advanced high temperature, microstrain resistant, materials such as amorphous tungsten; (3) location, description and temporal evolution of current, magnetic field, and losses during intense plasma-current field interactions with conductors; and (4) composite materials and sequentially sectioned structures for more efficient EM dc launcher configuration.

1982-07-14

486

Properties of molecular solids and fluids at high pressure and temperatures  

Energy Technology Data Exchange (ETDEWEB)

This renewal request for DOE grant DE-FG02-86ER45238, is dedicated to providing a complete thermodynamic profile of solids fluids, and fluid mixtures, over a wide range of temperatures and pressures. We are partially motivated by technological interest in detonation, combustion, superhard high pressure materials, and high temperature superconductors, which are important components of interest of various DOE laboratories. Our work on fluids and solids, composed of simple molecules, involves the determination of structures, phase transitions, pressure-volume relations, phonon, vibron, and libron modes of excitation, sound velocities, specific heats, thermal expansion, virial coefficients, sublimation energies, and orientational translational, and magnetic correlations. We hope that the study of these systems under extreme thermodynamic conditions will lead to exotic new materials of value, as well as enhanced fundamental understanding.

1992-03-01

487

Precision measurements of positronium decay rate and energy level  

CERN Document Server

Positronium is an ideal system for the research of the bound state QED. New precise measurement of orthopositronium decay rate has been performed with an accuracy of 150 ppm, and the result combined with the last three is 7.0401 +- 0.0007 mu s^-1. It is the first result to validate the 2nd order correction. The Hyper Fine Splitting of positronium is sensitive to the higher order corrections of the QED prediction and also to the new physics beyond Standard Model via the quantum oscillation into virtual photon. The discrepancy of 3.5 sigma is found recently between the measured values and the QED prediction (O(alpha^3)). It might be due to the contribution of the new physics or the systematic problems in the previous measurements: (non-thermalized Ps and non-uniformity of the magnetic field). We propose new methods to measure HFS precisely without the these uncertainties.

2008-01-01

488

Point defects in dilute nitride III-N-As and III-N-P  

International Nuclear Information System (INIS)

We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.

2006-04-01

489

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the potential benefits ...

2009-03-01

490

Mesodynamics in the SARS nucleocapsid measured by NMR field cycling  

Energy Technology Data Exchange (ETDEWEB)

Protein motions on all timescales faster than molecular tumbling are encoded in the spectral density. The dissection of complex protein dynamics is typically performed using relaxation rates determined at high and ultra-high field. Here we expand this range of the spectral density to low fields through field cycling using the nucleocapsid protein of the SARS coronavirus as a model system. The field-cycling approach enables site-specific measurements of R{sub 1} at low fields with the sensitivity and resolution of a high-field magnet. These data, together with high-field relaxation and heteronuclear NOE, provide evidence for correlated rigid-body motions of the entire {beta}-hairpin, and corresponding motions of adjacent loops with a time constant of 0.8 ns (mesodynamics). MD simulations substantiate these findings and provide direct verification of the time scale and collective nature of these motions.

2009-09-15

491

Long range ordering in self-assembled Ni arrays on patterned Si  

Energy Technology Data Exchange (ETDEWEB)

We have succeeded in aligning self-assembled structures by using a lithographically defined stripe. The 140 nm wide by 100 nm high SiO{sub 2} strip is shown to guide the assembly of 500 nm latex spheres so that spheres are aligned along the strip and are in registration on either side of the strip. This method can be used to increase long-range ordering in magnetic storage systems without compromising the density. Inverse sphere Ni arrays were made by electrodeposition through the latex template. We also show that the hexagonal symmetry of the resulting inverse sphere Ni arrays can be simulated using the approach presented below.

2007-09-15

492

Long range ordering in self-assembled Ni arrays on patterned Si  

International Nuclear Information System (INIS)

We have succeeded in aligning self-assembled structures by using a lithographically defined stripe. The 140 nm wide by 100 nm high SiO_2 strip is shown to guide the assembly of 500 nm latex spheres so that spheres are aligned along the strip and are in registration on either side of the strip. This method can be used to increase long-range ordering in magnetic storage systems without compromising the density. Inverse sphere Ni arrays were made by electrodeposition through the latex template. We also show that the hexagonal symmetry of the resulting inverse sphere Ni arrays can be simulated using the approach presented below.

2007-09-01

493

High-Gain Lasing and Polarization Switch with a Distributed Optical-Klystron Free-Electron Laser  

International Nuclear Information System (INIS)

This Letter reports the first experimental results from the world's first distributed optical-klystron (DOK) free-electron laser (FEL), the DOK-1 FEL, at Duke University. The DOK-1 FEL is a hybrid system, comprised of four wigglers: two horizontal and two helical. With the DOK-1 FEL, we have obtained the highest FEL gain among all storage ring based FELs at 47.8% (#+-#2.7%) per pass. We have also demonstrated that the FEL gain can be enhanced by increasing electron bunching using wigglers with a different polarization. Furthermore, we have realized controlled polarization switches of the FEL beam by a nonoptical means through the manipulation of a buncher magnet.

2006-06-09

494

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

495

Danger: high voltage  

Science.gov (United States)

Electric utilities have been surprised by recent opposition to the construction of very-high-voltage transmission lines, which met with little resistance in the past. Concerns over health and safety factors are associated with the increase in the number of such lines, although their presence has always been an inconvenience and a hazard for those living and working in the immediate vicinity. The new lines present additional hazards due to the continuous flow of small electric currents and the charges that build up in the area of the towers and lines. The lines are also a threat to persons wearing cardiac pacemakers. There is experimental evidence from the Soviet Union and the U.S. that electric and magnetic fields at the frequencies of such power lines can have serious biological effects on growth rates and the functioning of the central nervous system. Full disclosure that possible risks are involved and the opportunity to avoid these risks is ...

1978-05-01

496

Coherent spontaneous radiation of Frenkel excitons  

International Nuclear Information System (INIS)

We have constructed a mathematical model that describes the coherent spontaneous radiation of a macroscopically filled exciton mode. We have demonstrated qualitatively ways in which a coherent subsystem of excitons can be formed. When this occurs under the influence of an external coherent source, exciton free induction occurs, while in the case of a spontaneous transition of the excitons to a coherent state through freezing of the reservoir of intermolecular interactions superradiance occurs. We have concluded that superradiance in the system of Frenkel excitons is possible under the influence of the non-Dicke mechanisms of self-induction of correlations, when the dipole transition moments of the individual atoms are coupled into a single macroscopic effective spin through their electrostatic interaction, this being analogous to the ordering of magnetic dipole moments in a ferromagnet.

1988-01-01

497

Calculation of electromagnetic force in electromagnetic forming process of metal sheet  

International Nuclear Information System (INIS)

Electromagnetic forming (EMF) is a forming process that relies on the inductive electromagnetic force to deform metallic workpiece at high speed. Calculation of the electromagnetic force is essential to understand the EMF process. However, accurate calculation requires complex numerical solution, in which the coupling between the electromagnetic process and the deformation of workpiece needs be considered. In this paper, an appropriate formula has been developed to calculate the electromagnetic force in metal work-piece in the sheet EMF process. The effects of the geometric size of coil, the material properties, and the parameters of discharge circuit on electromagnetic force are taken into consideration. Through the formula, the electromagnetic force at different time and in different positions of the workpiece can be predicted. The calculated electromagnetic force and magnetic field are in good agreement with the numerical and experimental results. The accurate ...

2010-06-15

498

Application of high velocity impact welding at varied different length scales  

British Library Electronic Table of Contents (United Kingdom)

Three complementary impact welding technologies are described in this paper. They are explosive welding, magnetic pulse welding, and laser impact welding, which have been used to provide metallurgical bonds between both similar and dissimilar metal pairs. They share the physical principle that general impact-driven welding can be carried out by oblique impact but are used at different length scales from meters to sub-millimeter. The different length scales require different kinds of systems to drive the process, and the scales themselves can give different weld morphologies. Metallographic analysis on cross-sections shows a wavy interface morphology which is likely the result of an instability associated with jetting, which scours the surfaces clean during impact. The normalized period and...

2011-01-01

499

A He-gas Cooled, Stationary Granular Target  

CERN Document Server

In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.

2003-01-01