WorldWideScience
1

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

2

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

3

Studying the internal structure of granular magnetic nanocomposites by ferromagnetic resonance  

British Library Electronic Table of Contents (United Kingdom)

A method for estimating the form of magnetic nanoparticles in composite film structures based on the observation of ferromagnetic resonance phenomenon is offered. Within the model of the effective medium, an explanation is given for experimentally observed concentration and temperature dependences of resonant fields for composite nanosystem (Co45Fe45Z10) f +(Al2O3)100?f .

2010-01-01

4

Solid-state 13C NMR spectroscopy of a 13C carbonyl-labeled polypeptide  

UK PubMed Central (United Kingdom)

High resolution structural elucidation of macromolecular structure by solid-state nuclear magnetic resonance requires the preparation of uniformly aligned samples that are isotopically labeled. In...Full Text Available

1992-06-01

13

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

15

Teaching electron diffraction and imaging of macromolecules.  

UK PubMed Central (United Kingdom)

Electron microscopic analysis can be used to determine the three-dimensional structures of macromolecules at resolutions ranging between 3 and 30 A. It differs from nuclear magnetic resonance spectroscopy...Full Text Available

1993-05-01

16

Right-sided invasive metastatic thymoma of the heart  

British Library Electronic Table of Contents (United Kingdom)

Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.

2011-01-01

17

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

29

Current applications of magnetic resonance in coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)

1982-01-01

30

Multiple resonances and Coulomb blockade splitting in a quantum dot-DNA composite  

British Library Electronic Table of Contents (United Kingdom)

Inspired by the recent realizations of quantum dot (QD)-DNA conjugation, we study the spectral density of a magnetic impurity coupled to a mesoscopic semiconducting host. Using a combination of exact diagonalization technique and an analytic approach, we demonstrate that various types of resonances occur according to the relative position of impurity levels (IL) with respect to the host levels (HL). While the usual Coulomb peaks appear when the IL lie inside a band gap, with IL approaching HL and hybridization activated, they shift nonlinearly with the repulsion strength and even undergo splitting for a strong hybridization. When IL merge into HL, multiple resonances of a comblike structure are found along with a parity effect.

2011-01-01

31

Preparation and Properties of New Ester-Linked Cleavable Gemini Surfactants  

British Library Electronic Table of Contents (United Kingdom)

We have prepared a series of novel gemini surfactants having ester bonds in their structures. These surfactants possess two identical hydrophilic polyethylene glycol moieties, two hydrophobic alkyl group moieties, and an anionic spacer. The structures of these compounds were confirmed through infrared and nuclear magnetic resonance spectroscopic and elemental analyses. The novel gemini surfactants exhibit excellent surface activity in terms of their surface tension, low-foaming, wetting power, and fluorescence properties. The presence of the ester linkages made these structures cleavable surfactants.

2011-01-01

32

Structure of a mycobacterial polysaccharide-fatty acyl-CoA complex: nuclear magnetic resonance studies.  

UK PubMed Central (United Kingdom)

MMP, a linear alpha 1 leads to 4 linked polymer of 3-O-methylmannose, regulates the fatty acid synthetase from Mycobacterium smegmatis by forming stoichiometric complexes with the long-chain acyl-CoA...Full Text Available

1980-05-01

33

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection ...

34

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an ...

2002-08-01

35

Nuclear resonant spectroscopy at Bragg reflections from periodic multilayers: Basic effects and applications  

Science.gov (United States)

A systematic study of the Bragg nuclear resonant reflectivity from periodic multilayers in the energy and time domains is presented. Using the kinematical approach of the general reflectivity theory we describe the basic features of the time evolution of the reflected wave after a pulsed excitation of resonant multilayers by synchrotron radiation. Effects of the collective excitation have been examined such as the shift of quantum beat phases, the interplay between electronic and nuclear subsystem excitations depending on their relative position in a multilayer, the energy and time evolution of standing waves inside a resonant multilayer, and their influence on the reflectivity spectra. The exact expression for the reflectivity by a thin resonant layer placed inside a multilayer structure has been derived. The observed shift of the delayed reflectivity Bragg peak relative to the ...

2005-09-15

36

Characterization of proton exchange membrane materials for fuel cells by solid state nuclear magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel ...

2010-03-15

37

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

38

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

39

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

40

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

41

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

44

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

47

Influence of resonant US on H-NMR at application of magnetic nanoparticles  

International Nuclear Information System (INIS)

2010 [1 p.] Germany Repp, Felix El-Miladi, Nouri Hoehl, Christian Jahanbakhsh,

2010-03-21

51

Roles of the #beta# 146 histidyl residue in the molecular basis of the Bohr Effect of hemoglobin: A proton nuclear magnetic resonance study  

International Nuclear Information System (INIS)

Assessment of the roles of the carboxyl-terminal #beta#146 histidyl residues in the alkaline Bohr effect in human and normal adult hemoglobin by high-resolution proton nuclear magnetic resonance spectroscopy requires assignment of the resonances corresponding to these residues. By a careful spectroscopic study of human normal adult hemoglobin, enzymatically prepared des(His146#beta#)-hemoglobin, and the mutant hemoglobins Cowtown (#beta#146His #-># Leu) and York (#beta#146His #-># Pro), the authors have resolved some of these conflicting results. By a close incremental variation of pH over a wide range in chloride-free 0.1 M N-(2-hydroxyethyl)piperazine-N'-2-ethanesulfonic acid buffer, a single resonance has been found to be consistently missing in the proton nuclear magnetic resonance spectra of these hemoglobin variants. The results indicate that the ...

52

The magnetic resonance and its agro-industry applications; a review  

International Nuclear Information System (INIS)

The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage ...

53

Anisotropic magnetism in hybridizing uranium systems  

International Nuclear Information System (INIS)

The isostructural uranium monopnictides and monochalcogenides have become prototype systems in actinide research with respect to their unusual magnetic properties. We have investigated the origins in the electronic structure of the variation in magnetic behavior as the degree of 5f-electron localization changes from localized to itinerant on going up the pnictogen or chalcogen column, thus decreasing the U-U separation. We have applied a synthesis of: (1) A phenomenological theory of orbitally driven magnetic ordering which includes both the hybridization-induced and the RKKY exchange interactions on an equal footing, and (2) Ab initio electronic structure calculations, based on the linear-muffin-tin-orbital method, allowing a first-principles evaluation of the parameters entering the model Hamiltonian. We have investigated systematically characteristic trends and changes of the ...

54

Structure and magnetic properties of the UNi_1_0_-_xFe_xSi_2 system and "2"9Si nuclear magnetic resonance in UNi_1_0Si_2  

International Nuclear Information System (INIS)

Structure and magnetic properties of UNi_1_0_-_xFe_xSi_2 intermetallics and "2"9Si nuclear magnetic resonance (NMR) in UNi_1_0Si_2 are investigated in a wide temperature range. Solid solutions in the exactly single-phase tetragonal form, ThMn_1_2 type, exist for x<2. The Ni and Fe atoms occupy the 8(f), 8(i) and 8(j) positions statistically, whereas the U atoms occupy the 2(a) and the Si atoms the 8(j) sites. The lattice parameters roughly follow Vegard's law. The magnetic susceptibility does not exhibit Curie-Weiss behaviour and, at about 630 K, an anomaly in the temperature dependence is observed. At low temperature, other anomalies are observed at 32 K and 45 K, for x=0.5 and 1.0 respectively. These low temperature anomalies are probably connected with magnetic ordering of a ferromagnetic character, whereas that at 630 K might result from the ...

1993-09-01

55

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular ...

56

Electron paramagnetic resonance of nitroxide-doped magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.

2002-11-01

57

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE ...

1997-01-01

58

Inelastic electron scattering, M1 giant resonances and the quest for subnuclear degrees of freedom  

International Nuclear Information System (INIS)

... electrons fine structure giant resonance inelastic scattering iron 54 iron 54

1983-01-17

59

Magnetic resonance appearance of peripheral nerve sheath tumors  

International Nuclear Information System (INIS)

Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship between the lesions and the adjacent neurovascular ...

60

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the ...

1985-08-01

61

Experimental parameterization of an energy function for the simulation of unfolded proteins  

DEFF Research Database (Denmark)

The determination of conformational preferences in unfolded and disordered proteins is an important challenge in structural biology. We here describe an algorithm to optimize energy functions for the simulation of unfolded proteins. The procedure is based on the maximum likelihood principle and employs a fast and efficient gradient descent method to find the set of parameters of the energy function that best explain the experimental data. We first validate the method by using synthetic reference data, and subsequently apply the algorithms to data from nuclear magnetic resonance spin-labeling experiments on the Delta 131 Delta fragment of Staphylococcal nuclease. A significant strength of the procedure that we present is that it directly uses experimental data to optimize the energy parameters, without relying on the availability of high resolution structures. The procedure is fully general and can be ...

2008-01-01

62

Towards Resonant-State THz Laser Based on Strained p-Ge ...  

Science.gov (United States)

... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...

2006-07-01

63

Tarlov Cyst and Infertility  

UK PubMed Central (United Kingdom)

Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available

2009-04-01

64

Magnetic resonance imaging in human lymphodemas  

International Nuclear Information System (INIS)

The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).

1989-09-02

68

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

69

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends ...

1995-12-31

71

Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?  

UK PubMed Central (United Kingdom)

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available

2009-03-01

72

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

73

Nuclear magnetic resonance and the question of 5f electron localization in the actinides  

International Nuclear Information System (INIS)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5f electrons. (author).

74

Nuclear magnetic resonance and the question of 5F electron localization in the actinides  

Science.gov (United States)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5Line integral electrons.

1976-01-01

75

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

76

Magnetic resonance appearance of fibromatosis  

International Nuclear Information System (INIS)

We reviewed retrospectively the magnetic resonance (MR) images of 14 soft-tissue lesions of fibromatosis (desmoid tumors) encountered in 11 patients. The lesions were typically inhomogeneous in texture and round to oval in configuration. Margins were well-defined in 78% of the lesions at presentation and were infiltrating in all recurrences. (orig./DG).

77

Fatty acid distribution in systems modeling the normal and diabetic human circulation. A 13C nuclear magnetic resonance study.  

UK PubMed Central (United Kingdom)

A nonperturbing 13C nuclear magnetic resonance (NMR) method was used to monitor the equilibrium distribution of carboxyl 13C-enriched fatty acids (FA) between distinct binding sites on human serum albumin,...Full Text Available

1991-04-01

78

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

79

Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness  

UK PubMed Central (United Kingdom)

BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available

80

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac ...

2009-03-01

81

Effect of magnet sorting using a simple resonance cancellation method on the RMS orbit distortion at the APS injector synchrotron  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.

1993-07-01

82

Nuclear magnetic resonance spectroscopy in the structure elucidation and biosynthesis of natural products  

Energy Technology Data Exchange (ETDEWEB)

Examination of a chloroform extract of Dracaena loureiri Gagnep (Agavaceae), a Thia medicinal plant possessing antibacterial activity, has led to the isolation of fifteen flavenoids. The biogenic relationships among these flavenoids isolated were briefly discussed. Definition of the skeleton and the unambiguous assignment of all of the protons of the isolates was achieved through extensive 2D-homonuclear chemical shift correlation, nuclear Overhauser effect (NOE) difference spectroscopy and 2D-NOE experiments. The {sup 1}H and {sup 13}C NMR spectra of staurosporine, a potent biologically active agent from Streptomyces staurosporeus, were unambiguously assigned by using 2D homonuclear chemical shift correlation, NOE, {sup 1}H-detected heteronuclear multiple-quantum coherence via direct coupling and via multiple-bond coupling for resonance assignments of protonated and nonprotonated carbons, respectively. S. Staurosporeus was found to utilize endogenous and exogenous ...

1988-01-01

83

Pituitary disease in childhood: utility of magnetic resonance; Patologia hipofisaria en la edad pediatrica: unidad de la resonance magnetica  

Energy Technology Data Exchange (ETDEWEB)

To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children ...

2000-07-01

85

Physical basis of the effect of hemoglobin on the "3"1P NMR chemical shifts of various phosphoryl compounds  

International Nuclear Information System (INIS)

The marked difference between the intra- and extracellular "3"1P NMR chemical shifts of various phosphoryl compounds when added to a red cell suspension may be largely understood in terms of the effects of hemoglobin on the "3"1P NMR chemical shifts. The presence of [oxy- or (carbonmonoxy)-] hemoglobin inside the red cell causes the bulk magnetic susceptibility of the cell cytoplasm to be significantly less than that of the external solution. This difference is sufficient to account for the difference in the intra- and extracellular chemical shifts of the two phosphate esters trimethyl phosphate and triethyl phosphate. However, in the case of the compounds dimethyl methylphosphonate, diethyl methylphosphonate, and trimethylphosphine oxide as well as the hypophosphite, phenylphosphinate, and diphenylphosphinate ions, hemoglobin exerts an additional, much larger, effect, causing the "3"1P NMR resonances to shift to lower frequency in a manner ...

86

Visualization and volumetric structures from MR images of the brain  

Energy Technology Data Exchange (ETDEWEB)

Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows ...

1994-03-01

87

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li{sub 2}S-SiS{sub 2}-Li{sub 3}PO{sub 4} Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li{sub 2}S{center_dot}0.4SiS{sub 2})centre dotxLi{sub 3}PO{sub 4} oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO{sub n}S{sub 4-n} (n=1,2,3) and PO{sub n}S{sub 4-n} (n=1,2,3) present in the glass samples vanished and the SiS{sub 4}, PS{sub 4}, SiO{sub 4} units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S{sup 2-} increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

88

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li[sub 2]S-SiS[sub 2]-Li[sub 3]PO[sub 4] Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li[sub 2]S[center dot]0.4SiS[sub 2])centre dotxLi[sub 3]PO[sub 4] oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO[sub n]S[sub 4-n] (n=1,2,3) and PO[sub n]S[sub 4-n] (n=1,2,3) present in the glass samples vanished and the SiS[sub 4], PS[sub 4], SiO[sub 4] units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S[sup 2-] increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

89

High-temperature ferromagnetism in laser-deposited layers of silicon and germanium doped with manganese or iron impurities  

Energy Technology Data Exchange (ETDEWEB)

The paper reports on the results of a study of the synthesis conditions effects on magnetic and transport properties of nanosized layers of high-T{sub c} diluted magnetic semiconductors (DMS), such as Ge:Mn, Si:Mn and Si:Fe, fabricated by laser-plasma deposition over a wide range of the growth temperature, T{sub g}=(20-550) deg. C on single-crystal GaAs or Al{sub 2}O{sub 3} substrates. Ferromagnetism of the layers was detected by measurement data of the magneto-optical Kerr effect, anomalous Hall effect, negative magnetoresistance and ferromagnetic resonance (FMR) at 5-500 K. The optimum growth temperature, T{sub g}, for Si:Mn/GaAs layers with T{sub c}{approx}400 K is shown to be about 400 deg. C. The Si:Mn/Al{sub 2}O{sub 3} layers with 35% of Mn have the metal-type of conductivity with manifestation of magnetization up to room temperature. Different types of uniformly doped ...

2009-04-15

90

Kondo effect in the systems of magnetic trimers on a metal surface  

International Nuclear Information System (INIS)

Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)

2010-11-01

91

Continuum damping of toroidal Alfven eigenmodes in finite-#beta# tokamak equilibria  

International Nuclear Information System (INIS)

A general theoretical approach for the study of the two-dimensional structure of high-n Toroidal Alfven Eigenmodes (TAE) in finite-#beta#, large aspect ratio (R_o/a much-gt 1) tokamak equilibria is presented. Here, n is the toroidal mode number, #beta# = plasma/magnetic pressure, and a(R_o) is the minor (major) radius of the torus. It is shown how the general pseudo-differential boundary value problem for the radial eigenmode structure can be systematically constructed from the local dispersion relation; which is obtained using the ballooning formalism. The TAE modes are characterized by a broad radial envelope, the width of which is independent on the mode number in the general case of monotonic equilibrium profiles. The results on the two-dimensional eigenmode structure are expected to be applicable to drift-type waves. The ballooning transform is generalized here to handle singular eigenfunctions ...

92

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

93

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ...

2005-04-01

94

Nuclear magnetic resonance on oriented XVTa and XXTa  

Energy Technology Data Exchange (ETDEWEB)

XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.

1984-08-01

95

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

96

The Influence of Moderate Hypercapnia on Neural Activity in the Anesthetized Nonhuman Primate  

UK PubMed Central (United Kingdom)

Hypercapnia is often used as vasodilatory challenge in clinical applications and basic research. In functional magnetic resonance imaging (fMRI), elevated CO2 is applied to derive stimulus-induced...Full Text Available

2008-11-01

97

Synthesis and characterization of PVP-coated large core iron oxide nanoparticles as an MRI contrast agent  

UK PubMed Central (United Kingdom)

The purpose of this study was to synthesize biocompatible polyvinylpyrrolidone (PVP)-coated iron oxide (PVP-IO) nanoparticles and to evaluate their efficacy as a magnetic resonance imaging (MRI)...Full Text Available

2008-04-01

98

Specialization along the Left Superior Temporal Sulcus for Auditory Categorization  

UK PubMed Central (United Kingdom)

The affinity and temporal course of functional fields in middle and posterior superior temporal cortex for the categorization of complex sounds was examined using functional magnetic resonance imaging...Full Text Available

2010-12-01

99

Retinal channelrhodopsin-2-mediated activity in vivo evaluated with manganese-enhanced magnetic resonance imaging  

UK PubMed Central (United Kingdom)

PurposeEctopic expression of light-sensitive proteins, such as channelrhodopsin-2, represent a novel approach for restoring light-detection capabilities to degenerated retina. A...Full Text Available

100

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

101

Nylon biodegradation by lignin-degrading fungi.  

UK PubMed Central (United Kingdom)

The biodegradation of nylon by lignin-degrading fungi was investigated. The fungus IZU-154 significantly degraded nylon-66 membrane under ligninolytic conditions. Nuclear magnetic resonance analysis...Full Text Available

1997-01-01

102

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

103

New approach to study fast and slow motions in lipid bilayers: application to dimyristoylphosphatidylcholine-cholesterol interactions.  

UK PubMed Central (United Kingdom)

Natural abundance 13C solid-state nuclear magnetic resonance spectroscopy was used to investigate the effect of the incorporation of cholesterol on the dynamics of dimyristoylphosphatidylcholine (DMPC)...Full Text Available

1995-05-01

104

Neurosarcoidosis--demonstration of meningeal disease by gadolinium enhanced magnetic resonance imaging.  

UK PubMed Central (United Kingdom)

Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available

1991-06-01

105

Monitoring of Tumor Promotion and Progression in a Mouse Model of Inflammation-Induced Colon Cancer with Magnetic Resonance Colonography1  

UK PubMed Central (United Kingdom)

Early detection of precancerous tissue has significantly improved survival of most cancers including colorectal cancer (CRC). Animal models designed to study the early stages of cancer are valuable...Full Text Available

2009-03-01

106

Measuring the thickness of the human cerebral cortex from magnetic resonance images  

UK PubMed Central (United Kingdom)

Accurate and automated methods for measuring the thickness of human cerebral cortex could provide powerful tools for diagnosing and studying a variety of neurodegenerative and psychiatric disorders....Full Text Available

2000-09-26

107

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

108

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models  

UK PubMed Central (United Kingdom)

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation....Full Text Available

2009-05-01

109

MRI Findings of Pericardial Fat Necrosis: Case Report  

UK PubMed Central (United Kingdom)

Pericardial fat necrosis is an infrequent cause of acute chest pain and this can mimic acute myocardial infarction and acute pericarditis. We describe here a patient with the magnetic resonance imaging...Full Text Available

2011-05-01

112

Interictal Functional Connectivity of Human Epileptic Networks Assessed by Intracerebral EEG and BOLD Signal Fluctuations  

UK PubMed Central (United Kingdom)

In this study, we aimed to demonstrate whether spontaneous fluctuations in the blood oxygen level dependent (BOLD) signal derived from resting state functional magnetic resonance imaging (fMRI) reflect...Full Text Available

113

In vivo study of chloroplast volume regulation.  

UK PubMed Central (United Kingdom)

This paper describes a new technique that can be used to study chloroplast volume regulation in vivo. Nuclear magnetic resonance spectroscopy was used to measure relative amounts of chloroplast water...Full Text Available

1992-05-01

114

Energy metabolism of the untrained muscle of elite runners as observed by 31P magnetic resonance spectroscopy: evidence suggesting a genetic endowment for endurance exercise.  

UK PubMed Central (United Kingdom)

The purpose of this study was to investigate whether genetically determined properties of muscle metabolism contribute to the exceptional physical endurance of world-class distance runners. ATP, phosphocreatine,...Full Text Available

1988-12-01

115

Effects of norepinephrine infusion on myocardial high-energy phosphate content and turnover in the living rat.  

UK PubMed Central (United Kingdom)

Using 31P-nuclear magnetic resonance, we studied the relationship between myocardial high-energy phosphate content and flux values for the creatine kinase reaction in the living rat under inotropic...Full Text Available

1987-06-01

116

EXPONENTIAL TENSORS: A FRAMEWORK FOR EFFICIENT HIGHER-ORDER DT-MRI COMPUTATIONS  

UK PubMed Central (United Kingdom)

In Diffusion Tensor Magnetic Resonance Image (DT-MRI) processing a 2nd order tensor has been commonly used to approximate the diffusivity function at each lattice...Full Text Available

2007-05-15

117

Current Role and Future Perspectives of Magnetic Resonance Spectroscopy in Radiation Oncology for Prostate Cancer  

UK PubMed Central (United Kingdom)

Prostatic neoplasms are not uniformly distributed within the prostate volume. With recent developments in three-dimensional intensity-modulated and imageguided radiation therapy, it is possible to treat...Full Text Available

2007-06-01

118

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

119

Cardiovascular magnetic resonance guided electrophysiology studies  

UK PubMed Central (United Kingdom)

Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available

120

Calorimetric and spectroscopic studies of the polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines.  

UK PubMed Central (United Kingdom)

The polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines was investigated by differential scanning calorimetry, 31P-nuclear magnetic resonance, and Fourier...Full Text Available

1993-04-01

121

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

122

Quantum molecular dynamics and molecular interactions studied by NMR and INS[Nuclear magnetic resonance; Proton tunnelling; Hydrogen bond  

Energy Technology Data Exchange (ETDEWEB)

The wavefunction of a particle extends into the classically forbidden barrier region of the potential energy surface. The consequence of this partial delocalisation is the phenomenon of quantum tunnelling, an effect which enables a particle to penetrate a potential barrier of magnitude greater than the energy of the particle. The tunnelling probability is an exponential function of the particle mass. The effect is therefore an important contribution to the behaviour of light atoms, in particular the proton. The hydrogen bond has long been appreciated to be an essential component of many biological and chemical systems, and the proton transfer reaction in the hydrogen bond is fundamental to many of these processes. The proton behaviour in the hydrogen bonds of benzoic acid, acetylacetone and calix-4-arene has been studied. A variety of techniques, both experimental and computational, were adopted for the study of the three hydrogen bonded systems. The complementary spectroscopic ...

2002-07-01

123

Nuclear magnetic resonance spectroscopy in biomedicine. Course organized by the Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), September 18-23, 1995; Spettroscopia di risonanza magnetica nucleare in biomedicina. Corso organizzato dall`Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), 18-23 settembre 1995  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di ...

1997-12-01

124

Polarized proton acceleration at the Brookhaven AGS  

Energy Technology Data Exchange (ETDEWEB)

At the conclusion of polarized proton commissioning in February 1986, protons with an average polarization of 45%, momentum of 21.7 GeV/c, and intensity of 2 x 10/sup 10/ protons per pulse, were extracted to an external polarimeter at the Brookhaven AGS. In order to maintain this polarization, five intrinsic and nearly forty imperfection depolarizing resonances had to be corrected. An apparent interaction between imperfection and intrinsic resonances occurring at very nearly the same energy was observed and the correction of imperfection resonances using ''beat'' magnetic harmonics discovered in the previous AGS commissioning run was further confirmed.

1986-01-01

125

Models of cardiac electromechanics based on individual hearts imaging data  

British Library Electronic Table of Contents (United Kingdom)

Current multi-scale computational models of ventricular electromechanics describe the full process of cardiac contraction on both the micro- and macro- scales including: the depolarization of cardiac cells, the release of calcium from intracellular stores, tension generation by cardiac myofilaments, and mechanical contraction of the whole heart. Such models are used to reveal basic mechanisms of cardiac contraction as well as the mechanisms of cardiac dysfunction in disease conditions. In this paper, we present a methodology to construct finite element electromechanical models of ventricular contraction with anatomically accurate ventricular geometry based on magnetic resonance and diffusion tensor magnetic resonance imaging of the heart. The electromechanical model couples detailed repres...

2011-01-01

126

Inborn Errors of Metabolism Presenting in Childhood  

British Library Electronic Table of Contents (United Kingdom)

Abstract Neurodegenerative and neurometabolic disorders may cause significant morbidity and mortality in children. Imaging is important in early diagnosis of metabolic disorders and in determining the extent of brain injury. Especially after the development of new techniques such as diffusion-weighted magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), neuroimaging plays more important role in the diagnosis and management of these disorders. In these disorders, usually a mutation causes a clinically significant block in one or more metabolic pathways. This blockage usually results in either a deficiency of the product or in an accumulation of substrate with damage induced by either storage or toxicity. The presenting symptoms are usually nonspecific. In some of the ...

2011-01-01

127

In vivo magnetic resonance techniques and drug discovery  

International Nuclear Information System (INIS)

The long and resource intensive process of drug discovery and development is confronted with the basic challenge of providing effective and safe therapies at reasonably low costs. The better the mechanism of a disease is known, the higher the probability to find an appropriate therapy. Also, the better and earlier a disease can be diagnosed and characterized, the higher the chance to be able to interfere in this process with a chemical entity. This reasoning sets the framework for the use of imaging in drug discovery. We discuss the relevance of magnetic resonance imaging and spectroscopy to derive anatomical, functional, metabolic and target-related information in the context of pharmacological research in vivo. (author)

2006-03-01

128

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

129

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

130

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

131

MRI of normal fetal brain development  

International Nuclear Information System (INIS)

Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the arrangement of microanatomical structures to create a ...

2006-02-01

132

Magnetic resonance studies of photosynthetic reaction centers and porphyrins  

Science.gov (United States)

During the period covered by this report research has been concerned with the study of photo-induced electron transfer reactions from porphyrins to acceptor molecules with time-resolved Electron Paramagnetic Resonance (EPR) methods. Excited-state electron transfer reactions are of importance from a fundamental point of view and in connection with applications in homogeneous and heterogeneous photosensitization, photopolymerization, and solar energy conversions. For this reason, the study of photo-induced electron transfer reactions is of considerable interest.

1989-11-01

133

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of ...

2009-02-21

134

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of ...

2009-02-21

135

Nanocrystalline permanent magnets with enhanced properties  

International Nuclear Information System (INIS)

Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

2001-09-23

141

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

Energy Technology Data Exchange (ETDEWEB)

Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, ...

2008-07-15

142

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

International Nuclear Information System (INIS)

Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of ...

2008-07-01

143

Engineering electromagnetic response of composite terahertz metamaterial with broken symmetry  

Science.gov (United States)

We proposed and numerically investigated the influence of spatial symmetry on the terahertz frequency region response of composite planar metamaterials based on deformed split ring resonators. Compared with the original simple structures, the composite metamaterials with different spatial symmetries exhibited exotic electromagnetic properties. The electromagnetic response of a specific configuration with C4 symmetry was identical to the structure with simple lattice. Especially, for configurations with broken symmetry, very sharp Drude-like resonances with high quality factor were observed. The electric field and current distribution associated the resonances were analyzed for deep understanding of the underlying physical properties.

2011-09-01

144

Potential anti fungal agents. Synthesis and activity of 2-alkylthiopyridine-4-carbothioamides  

Energy Technology Data Exchange (ETDEWEB)

A series of 2-alkylthiopyrine-4-carbothioamides were synthesized, and their anti-fungal potency was tested. The chemical structures were proved by infrared spectroscopy (IR) and {sup 1}H nuclear magnetic resonance ({sup 1}H-NMR) data and by elemental analysis. The minimal inhibitory concentration (MIC) and minimal fungicidal concentration (MFC) assessment were used for the estimation of potential activity in vitro. The study comprising 21 clinical isolates of fungi showed that two compounds exhibited fair inhibitory activity against some yeasts and dermatophytes. Selective fungistatic activity against non-dermatophytes (MIC = 3.12-25.0 {mu}g/mL) was found also in another compound. None of the above compounds showed inhibitory activity against non-dermatophyte filamentous fungi. Microbiological activity of 2-alkylthiopyridine-4-carbothioamides appears to be mainly related to hydrophobicity of alkyl in position 2. (authors). ...

1996-05-01

145

Crystal growth, structural and optical characterization of a semi-organic single crystal for frequency conversion applications  

International Nuclear Information System (INIS)

Single crystals of semi-organic L-histidine hydrobromide have been grown by slow evaporation technique from a mixture of L-histidine and hydrobromic acid in aqueous solution at ambient temperature. From high-resolution X-ray diffraction analysis, the crystalline perfection of the grown crystal has been studied. Single crystal X-ray diffraction analyses, Nuclear Magnetic Resonance spectral analysis, Thermo-Gravimetry (TG), Differential Thermal Analysis (DTA) and hardness test have been employed to characterize the as-grown crystals. The UV cutoff wavelength of the grown crystal is below 300 nm and has a wide transparency window, which is suitable for second harmonic generation of laser in the blue region. Nonlinear optical characteristics have been studied using Q switched Nd:YAG laser (#lambda#=1064 nm). The second harmonic generation conversion efficiency of the grown crystals confirms their suitability for frequency conversion applications.

2010-12-15

146

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of ...

1988-01-01

147

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

148

Nuclear magnetic resonance study of La_3X compounds and related phases  

International Nuclear Information System (INIS)

Normal state nuclear magnetic resonance studies of the La_3In, La_3Tl compounds have been made in order to investigate the origin of the large temperature-dependent magnetic susceptibility. It is possible to analyse the different contributions to the susceptibility using Knight-shift and relaxation time T_1 measurements of In"1"1"5 and Tl"2"0"5 nuclei. The exchange enhancement of the spin-susceptibility chisub(pd) is of the same order as that found in A-15 compounds and the strong temperature-dependence of chi(T) is attributed to the presence of a peak in the electronic density of states near the Fermi level. The variation of the Knight-shift in the ternary alloys La_3Xsub(1-y)Xsub(y)sup(') is analogous to that observed in the corresponding La_3X phases, on the other hand the Knight-shift in the carbides La_3XC is temperature independent. (author).

149

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were presented as color-coded anatomically-mapped ...

150

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower ...

1993-06-01

151

Crossover of the magnetic levels and adiabatic magnetization of the mesoscopic cluster V15  

British Library Electronic Table of Contents (United Kingdom)

The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...

2006-01-01

152

Effective medium theory of the one-dimensional resonance phononic crystal  

International Nuclear Information System (INIS)

A general theoretical scheme to describe the effective modulus and mass density for acoustic metamaterials is presented. For such a purpose, an effective medium theory of a one-dimensional acoustic waveguide containing subwavelength-sized Helmholtz resonators is formulated. It is shown that, when the wavelength is much larger than the periodic length and the size of the resonators, the whole composite structure can be treated as an effective homogeneous medium in accounting for its acoustic properties. It is also shown that the acoustic characteristics, such as the effective modulus and the effective mass density, can be determined precisely from the transmission and the reflection data. The calculated effective modulus and effective mass density confirm that this structure behaves as a homogeneous metamaterial with a negative effective modulus in a frequency range just above the ...

2008-02-06

153

Resonances in gravitational scenario given by deformed branes  

Science.gov (United States)

In this work we examine a five-dimensional brane-world model with brane structure driven by a real scalar field. From the deformation of a kink-like defect we find a new class of brane solutions containing internal structures which have implications for the way the background space-time is constructed and the way its curvature behaves. Initially, for spin 0 scalar field, we find a zero mode which can be localized on the deformed brane. However, this result can change by the gravitational interaction with the brane internal structure. Analyzing the massive modes of the scalar field, using two different methods, we find resonance structures similar to those found in the study of gravity localization. The main objective here is to observe the contributions of the deformation procedure to the resonances and to the well known field localization methods.

2011-08-01

154

Development of magnetic drive packless valves for commercial purpose  

Energy Technology Data Exchange (ETDEWEB)

A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the ...

1995-09-01

155

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

156

A dinuclear Ni(I) system having a diradical Ni2N2 diamond core resting state: synthetic, structural, spectroscopic elucidation, and reductive bond splitting reactions.  

Science.gov (United States)

One-electron reduction of the square-planar nickel precursor (PNP)NiCl ( 1) (PNP (-) = N[2-P(CHMe 2) 2-4-methylphenyl] 2) with KC 8 effects ligand reorganization of the pincer ligand to assemble a Ni(I) dimer, [Ni(mu 2-PNP)] 2 ( 2), containing a Ni 2N 2 core structure, as inferred by its solid-state X-ray structure. Solution magnetization measurements are consistent with a paramagnetic Ni(I) system likely undergoing a monomer dimer equilibrium. The room-temperature and 4 K solid-state X-band electron paramagnetic resonance (EPR) spectra display anisotropic signals. Low-temperature solid-state X-band EPR data at 4 K reveal rhombic values g z = 1.980(4), g x = 2. 380(4), and g y = 2.225(4), as well as a forbidden signal at g = 4.24 for the Delta M S = 2 half field transition, in accord with 2 having two weakly interacting metal centers. Utilizing an S = 1 model, full spin Hamiltonian simulation of the ...

2008-10-15

157

Ultrasensitive laser isotope analysis in an ion-storage ring  

Energy Technology Data Exchange (ETDEWEB)

We propose a novel method for ultrasensitive isotope analysis that combines magnetic mass selection, resonant charge-exchange neutralization, and resonant laser ionizaion. Our method attains high isotopic abundance selectivity by means of continuous multistage separation of ions stored in a small ring. For the environmentally interesting case of /sup 90/Sr versus /sup 88/Sr we estimate that sensitivity better than 10/sup -15/ for a throughput of 10/sup 13/ atoms/sec and an efficiency (after the ion source) greater than 10% are readily achievable.

1985-09-01

158

Trapping of neutral atoms with resonant microwave radiation  

Energy Technology Data Exchange (ETDEWEB)

We duscuss a resonant microwave trap for neutral atoms. Because of the long spontaneous radiation time this trap is remarkably different from the optical trap. It also has advantages over static magnetic traps that trap the excited spin state of the lowest electronic level, in that atoms predominantly in the spin ground state can be trapped. We analyze the relaxation-ejection lifetime of atoms in such a trap using the formalism of dressed atomic states. Results are appliedi to atomic hydrogen and the possibility of Bose-Einstein condensation is considered.

1989-05-15

159

The Proton structure function F(2) in the resonance region  

Energy Technology Data Exchange (ETDEWEB)

Unique measurement of the proton structure function F2 in a wide two-dimensional region of x and Q**2 has been reported. The accessible kinematics covers entire resonance region up to W=2.5 GeV in the Q**2 interval from 0.1 to 4.5 GeV**2. Obtained data allowed for the first time an evaluation of moments of the structure function F2 directly from experimental data as well as an intensive study of the Bloom-Gilman duality phenomenon.

2003-06-01

160

Proton and deuteron spin structure function measurements in the resonance region  

Energy Technology Data Exchange (ETDEWEB)

The RSS collaboration has measured the spin structure functions of the proton and the deuteron at Jefferson Lab using the Hall C HMS spectrometer, a polarized electron beam and a polarized solid target. The asymmetries A and A were measured in the region of the nucleon resonances (0.82 GeV < W < 1.98 GeV) at an average four momentum transfer of Q2 = 1.3 GeV2. The extracted spin structure functions and their kinematic dependence will make a significant contribution in the study of higher-twist effects and polarized duality tests. A description of the experiment and the latest findings of the analysis will be presented.

2003-07-01

161

Quasi-ternary nanoparticle superlattices through nanoparticle design  

Energy Technology Data Exchange (ETDEWEB)

Individual nanoscale building blocks exhibit a wide range of size-dependent properties, since their size can be tuned over known characteristic length scales of bulk materials. In the last several years, the possibility of combining different materials in the form of two and three component nanoparticles (NPs) has been extensively explored. Also multi-component materials can be obtained via self-assembly of NPs from their binary colloidal mixtures. These new nanocrystal solids may possess tunable collective properties that originate from interactions between size and composition controlled building blocks. Exchange coupling between neighboring NPs of magnetically soft and hard materials enhances the magnetic energy product of the nanocomposite material. Randomly mixed solids of small and large semiconducting CdSe NPs revealed enhancement of photoluminescence intensity of large semiconductor particles accompanied by quenching of ...

2007-06-19

162

Intrinsic magnetism in Fe doped SnO2 nanoparticles  

International Nuclear Information System (INIS)

Iron doped semiconducting nanoparticles Sn1-xFexO2 with x=0, 0.001, 0.002, 0.003, 0.004, 0.01 and 0.03 were prepared by a sol-gel method. The X-ray diffraction, Transmission Electron Microscopy measurements confirm the rutile structure with no impurity phase. The three characteristic lines of electron spin resonance (ESR) are observed in the doped samples for all compositions, which is a clear evidence for rhombic Fe3+ in rutile phase. The line width of ESR increases with increase in Fe concentration due to induced disorder. The spin-pumping effect is observed at temperatures below 250 K for the samples with x=0.01 and 0.03. However, based on the Curie-Weiss susceptibility, iron is in paramagnetic state and is subject to weak antiferromagnetic interaction. Blue shift in the optical band gap is observed with increase in the Fe content. -- Graphical abstract: The ESR spectra reveal that the nature of Fe in Sn1-xFexO2 samples is isolated rhombic ...

2011-01-01

163

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

164

Primary cutaneous Ewing's sarcoma/primitive neuroectodermal tumor manifesting numerous small and huge ulcerated masses: its complete remission by chemotherapy and magnetic resonance imaging findings  

International Nuclear Information System (INIS)

Extraskeletal Ewing's sarcoma (ES) and primitive neuroectodermal tumor (PNET) are widely regarded as clinically and histologically identical tumors which consist of small blue round cells. Extraskeletal ESs/PNETs usually occur in the deep soft tissues of the paraspinal region, chest wall, or lower extremities. However, superficially located cases, so-called cutaneous ESs/PNETs, are exceedingly rare, and the vast majority of the reported cases present as a single small mass. We present magnetic resonance imaging (MRI) findings and clinical course of a unique case of primary cutaneous ES/PNET presenting as numerous huge masses with severe ulceration on them. (orig.)

2010-06-01

165

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

166

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

167

Electron cyclotron current drive at {omega} approx. = {omega}{sub c} with X-mode launched from the low field side  

Energy Technology Data Exchange (ETDEWEB)

The electron cyclotron resonance layer in a tokamak, {omega}={omega}{sub c}(r), is not accessible by the extraordinary wave from the low field side, because it is shielded by a cutoff layer. However, a X-mode launched with a nonzero toroidal angle propagates at the cutoff parallel to the magnetic field and has a circular polarization. Therefore it can already at the cutoff layer interact efficiency with electrons via the Doppler shifted resonance. The driven current can be substantially higher than that driven by the second harmonic X-mode. The applicability of this current drive scheme is limited to rather low values of {omega}{sub p}{sup 2}/{omega}{sub c}{sup 2}, but may be of interest for high magnetic field devices. (author)

2000-02-01

168

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

169

Assessment of GABARAP self-association by its diffusion properties  

Energy Technology Data Exchange (ETDEWEB)

Gamma-aminobutyric acid type A receptor-associated protein (GABARAP) belongs to a family of small ubiquitin-like adaptor proteins implicated in intracellular vesicle trafficking and autophagy. We have used diffusion-ordered nuclear magnetic resonance spectroscopy to study the temperature and concentration dependence of the diffusion properties of GABARAP. Our data suggest the presence of distinct conformational states and provide support for self-association of GABARAP molecules. Assuming a monomer-dimer equilibrium, a temperature-dependent dissociation constant could be derived. Based on a temperature series of {sup 1}H{sup 15}N heteronuclear single quantum coherence nuclear magnetic resonance spectra, we propose residues potentially involved in GABARAP self-interaction. The possible biological significance of these observations is discussed with respect to alternative scenarios of oligomerization.

2010-09-15

170

Magnetic structure of Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2  

International Nuclear Information System (INIS)

The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).

171

Theory of zwitterionic molecular-based organic magnets  

British Library Electronic Table of Contents (United Kingdom)

We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.

2011-01-01

172

Quark-Hadron Duality: Resonances and the Onset of Scaling  

Energy Technology Data Exchange (ETDEWEB)

We discuss the origin of Bloom-Gilman duality and the relationship between resonances and scaling in deep-inelastic scattering. We present a simple quantum mechanical model which reproduces the essential features of Bloom-Gilman duality at low Q{sup 2}, and describe applications of local duality relating structure functions at x{approximately}1 and elastic electromagnetic form factors.

2001-03-01

173

Multi-channel algebraic scattering theory and the structure of exotic compound nuclei  

CERN Document Server

A Multi-Channel Algebraic Scattering (MCAS) theory is presented with which the properties of a compound nucleus are found from a coupled-channel problem. The method defines both the bound states and resonances of the compound nucleus, even if the compound nucleus is particle unstable. All resonances of the system are found no matter how weak and/or narrow. Spectra of mass-7 nuclei and of {}^{15}F, and MCAS results for a radiative capture cross section are presented.

2007-01-01

174

Calculation of atomic spontaneous emission rate in 1D finite photonic crystal with defects  

CERN Document Server

We derive the expression for spontaneous emission rate in finite one-dimensional photonic crystal with arbitrary defects using the effective resonator model to describe electromagnetic field distributions in the structure. We obtain explicit formulas for contributions of different types of modes, i.e. radiation, substrate and guided modes. Formal calculations are illustrated with a few numerical examples, which demonstrate that the application of effective resonator model simplifies interpretation of results.

2009-01-01

175

Magnetic properties of a SmNiSn single crystal  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and ...

2003-04-01

176

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research ...

177

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high ...

2008-06-01

178

Negative group velocity from resonances in two-dimensional phononic crystals  

British Library Electronic Table of Contents (United Kingdom)

We investigate two routes to obtain negative group velocity bands in two-dimensional phononic crystal structures. The negative dispersion originates from the resonances of sub-wavelength building blocks and as such, the system should be regarded as acoustic metamaterials. The first kind of acoustic metamaterial exhibits effectively negative bulk modulus and negative mass density simultaneously. Monopolar and dipolar Mie resonances are combined to achieve an effective medium with negative refractive index. In particular, we present a double negative metamaterial for airborne sonic waves. We then show that we can obtain negative group velocity from quadrupole resonances, and the result is explained using the quasi-static approximation. The negative dispersion in quadrupole bands cannot be de...

2010-01-01

179

Numerical study of Cosmic Ray Diffusion in MHD turbulence  

CERN Document Server

We study diffusion of Cosmic Rays (CRs) in turbulent magnetic fields using test particle simulations. Electromagnetic fields are produced in direct numerical MHD simulations of turbulence and used as an input for particle tracing, particle feedback on turbulence being ignored. Statistical transport coefficients from the test particle runs are compared with earlier analytical predictions. We find qualitative correspondence between them in various aspects of CR diffusion. In the incompressible case, that we consider in this paper, the dominant scattering mechanism occurs to be the non-resonant mirror interactions with the slow-mode perturbations. Perpendicular transport roughly agrees with being produced by magnetic field wandering.

2010-01-01

180

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are ...

2004-11-01

181

IR double-resonance spectroscopy applied to the 4-aminophenol(H{sub 2}O){sub 1} cluster  

Energy Technology Data Exchange (ETDEWEB)

The IR double-resonance techniques IR/R2PI (infrared/resonant 2-photon ionization), IR/PIRI (infrared-photo-induced Rydberg ionization) and IR-photodissociation spectroscopy are valuable tools to investigate structure, vibrations, and dynamical processes of neutral and ionic hydrogen-bonded clusters containing aromatic molecules. In this paper we report on the application of the IR double-resonance techniques to determine the NH and OH stretching vibrations of 4-aminophenol and 4-aminophenol(H{sub 2}O){sub 1}, both in the neutral (S{sub 0}) and ionic (D{sub 0}) ground state. All vibrational frequencies obtained for 4-aminophenol and the cluster are compared with the values obtained from ab initio and DFT calculations. In the S{sub 0} state, a trans-linear arrangement of 4-aminophenol(H{sub 2}O){sub 1} is obtained containing an O-H. O hydrogen bond. In the D{sub 0} state an overlay of two spectra can be ...

2001-03-01

182

Duality in Neutrino Reactions  

Energy Technology Data Exchange (ETDEWEB)

On the basis of the phenomenological model for baryon resonance production in lepton nucleon and lepton nucleus scattering we investigate to what extent quark hadron duality is applicable to the neutrino structure functions and how it compares with duality in electron scattering.

2007-12-01

184

Radiation testing of organic ion exchange resins  

International Nuclear Information System (INIS)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total absorbed dose ...

1983-04-11

185

Radiation testing of organic ion exchange resins  

Energy Technology Data Exchange (ETDEWEB)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup 60}Co source to a total ...

1995-09-01

186

Viscoelastic locally resonant double negative metamaterials with controllable effective density and elasticity  

British Library Electronic Table of Contents (United Kingdom)

A metamaterial that is composed of solid viscoelastic elements with controllable properties is proposed in this Letter. This enables an adaptable and general acoustic metamaterial to be practically realised. An array of masses with a single elastic connection to a supporting viscoelastic structure, such as one that is dynamically equivalent to an array of Helmholtz resonators, only provides a system with negative effective mass. A local active control scheme applied to each of these masses can emulate additional elastic connections to the supporting structure. An array of masses with a suitable local control scheme can provide both the negative effective stiffness and mass required for negative refraction. The tuneable feedback control parameters determine the characteristics of the region...

2010-01-01

187

Acoustic resonances in two-dimensional radial sonic crystal shells  

Energy Technology Data Exchange (ETDEWEB)

Radial sonic crystals (RSC) are fluidlike structures infinitely periodic along the radial direction that verify the Bloch theorem and are possible only if certain specially designed acoustic metamaterials with mass density anisotropy can be engineered (see Torrent and Sanchez-Dehesa 2009 Phys. Rev. Lett. 103 064301). A comprehensive analysis of two-dimensional (2D) RSC shells is reported here. A given shell is in fact a circular slab with a central cavity. These finite crystal structures contain Fabry-Perot-like resonances and modes strongly localized at the central cavity. Semi-analytical expressions are developed to obtain the quality factors of the different resonances, their symmetry features and their excitation properties. The results reported here are completely general and can be extended to equivalent 3D spherical shells and to their photonic counterparts.

2010-07-15

188

Weak ferromagnets with integer and half-integer spin quantum numbers  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigations are presented which demonstrate that the weak ferromagnets are special materials of a larger group of magnets which exhibit two magnetic ordering structures. In weak ferromagnets the main order is antiferromagnetic with a small ferromagnetic component existing in addition. On the other hand, materials in which other combinations of the two basic ordering structures coexist are also known. Common to all these non-collinear spin structures is that the moment components of the two magnetic structures are orthogonal. In the weak ferromagnets this orthogonality manifests already in the paramagnetic phase as a crossover from an isotropic to an anisotropic susceptibility with respect to the applied magnetic field: at high temperatures the antiferromagnetic Curie-Weiss law of the total moment is ...

2005-01-31

189

The brain-derived neurotrophic factor Val66Met polymorphism is associated with reduced functional magnetic resonance imaging activity in the hippocampus and increased use of caudate nucleus-dependent strategies in a human virtual navigation task  

UK PubMed Central (United Kingdom)

Multiple memory systems are involved in parallel processing of spatial information during navigation. A series of studies have distinguished between hippocampus-dependent ‘spatial’ navigation,...Full Text Available

2011-03-01

190

Quality control in Nuclear Magnetic Resonance Imaging. Indications et strategies pour le controle de qualite en IRM  

Energy Technology Data Exchange (ETDEWEB)

In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.

1993-01-01

191

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

192

Metastatic Ewing's sarcoma to the skull: CNS involvement excluded by MRI  

International Nuclear Information System (INIS)

A case of metastatic Ewing's sarcoma to the skull is presented, demonstrating the superiority of magnetic resonance imaging over other imaging modalities to exclude CNS involvement. Precise delineation of different tumor components in extradural location contained in an intact dural rim together with compressed cortex showing no signs of tumorous involvement constituted an MRI appearance allowing us to exclude tumor outgrowth into the brain. (orig.).

193

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

194

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

195

MRI and 1H MRS of The Breast: Presence of a Choline Peak as Malignancy Marker is Related to k21 Value of the Tumor in Patients with Invasive Ductal Carcinoma  

UK PubMed Central (United Kingdom)

To assess which specific morphologic features, enhancement patterns, or pharmacokinetic parameters on breast Magnetic Resonance Imaging (MRI) could predict a false-negative outcome of Proton...Full Text Available

2008-01-01

196

MR findings of primary Ewing's sarcoma of greater wing of sphenoid  

International Nuclear Information System (INIS)

Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd

2002-12-01

197

Hyperfine interactions in HCOOD and DCOOH molecules  

Energy Technology Data Exchange (ETDEWEB)

The method of double microwave--radio-frequency resonance has been used to obtain spectra of the 2/sub 11/reverse arrow2/sub 12/ and 3/sub 21/reverse arrow3/sub 22/ transitions in HCOOD, DCOOH, and HCOOH molecules. The constants of the quadrupole bond of the deuterons have been determined, magnetic interactions being taken into acocunt. A comparison with results of previous studies is given.

1986-05-01

198

Electron phonon properties of A-15 compounds and Chevrel phases  

International Nuclear Information System (INIS)

A review of the information on the electron and phonon spectra in the A-15 compounds and Chevrel phase superconductors obtained from nuclear magnetic resonance, heat capacity, and Moessbauer effect experiments is presented. Relationships of the Fermi energy electrons and the soft phonons to the strength of the electron-phonon interaction are discussed.

199

Electron and phonon properties of A-15 compounds and Chevrel phases  

International Nuclear Information System (INIS)

A review of the information on the electron and phonon spectra in the A-15 compounds and Chevrel phase superconductors obtained from nuclear magnetic resonance, heat capacity, and Moessbauer effect experiments is presented. Relationships of the Fermi energy electrons and the soft phonons to the strength of the electron-phonon interaction are discussed.

200

Effect of Elicitation and Changes in Extracellular pH on the Cytoplasmic and Vacuolar pH of Suspension-Cultured Soybean Cells 1  

UK PubMed Central (United Kingdom)

We have employed both 31P nuclear magnetic resonance spectroscopy and two intracellular fluorescent pH indicator dyes to monitor the pH of the vacuole and cytoplasm of suspension-cultured...Full Text Available

1992-02-01

201

Characterization of polymers for microcellular foams  

Energy Technology Data Exchange (ETDEWEB)

We have measured, by {sup 1}H and {sup 13}C nuclear magnetic resonance (NMR), the percent deuteration, the tacticity and the purity of several polymers and one solvent used in the preparation of microcellular foams. The percent deuteration was measured for polystyrene, polyacrylonitrile and polyethylene. The tacticities of polystyrene and polyacrylonitrile were determined. The purity and degradation products of polyacrylonitrile and maleic anhydride were examined. This report documents the experimental procedures and results of these measurements.

1992-03-01

202

31P NMR Observations on the Effect of the External pH on the Intracellular pH Values in Plant Cell Suspension Cultures 1  

UK PubMed Central (United Kingdom)

31P nuclear magnetic resonance (NMR) spectroscopy was used to monitor the response of oil palm (Elaeis guineensis) and carrot (Daucus carota) cell suspensions...Full Text Available

1990-06-01

203

Spatial Damping of Propagating Kink Waves Due to Resonant Absorption: Effect of Background Flow  

CERN Document Server

Observations show the ubiquitous presence of propagating magnetohydrodynamic (MHD) kink waves in the solar atmosphere. Waves and flows are often observed simultaneously. Due to plasma inhomogeneity in the perpendicular direction to the magnetic field, kink waves are spatially damped by resonant absorption. The presence of flow may affect the wave spatial damping. Here, we investigate the effect of longitudinal background flow on the propagation and spatial damping of resonant kink waves in transversely nonuniform magnetic flux tubes. We combine approximate analytical theory with numerical investigation. The analytical theory uses the thin tube (TT) and thin boundary (TB) approximations to obtain expressions for the wavelength and the damping length. Numerically, we verify the previously obtained analytical expressions by means of the full solution of the resistive MHD eigenvalue problem beyond the TT ...

2011-01-01

204

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists ...

1991-09-15

205

Structure functions at low Q^2: higher twists and target mass effects  

Energy Technology Data Exchange (ETDEWEB)

We review the physics of structure functions at low Q{sup 2}, focusing on the phenomenon of quark-hadron duality and the resonance-scaling transition, both phenomenologically and in the context of quark models. We also present a new implementation of target mass corrections to nucleon structure functions which, unlike existing treatments, has the correct kinematic threshold behavior at finite Q{sup 2} in the x -> 1 limit.

2006-05-22

206

Ab initio calculations in a uniform magnetic field using periodic supercells  

Energy Technology Data Exchange (ETDEWEB)

We present a formulation of ab initio electronic structure calculations in a finite magnetic field, which retains the simplicity and efficiency of techniques widely used in first principles molecular dynamics simulations, based on plane-wave basis sets and Fourier transforms. In addition we discuss results obtained with this method for the energy spectrum of interacting electrons in quantum wells, and for the electronic properties of dense fluid deuterium in a uniform magnetic field.

2003-10-21

207

Nuclear magnetic resonance on oriented "1"7"5Ta and "1"7"7Ta  

International Nuclear Information System (INIS)

"1"7"5Ta and "1"7"7Ta nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies #nu#="+#mu#B sub(HF)/Ih"+ of the "1"7"5Ta and "1"7"7Ta ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of "1"8"1Ta in Fe, the magneticmoments have been deduced: "+#mu#("1"7"5Ta, 7/2"+)"+=2.270(45) and "+#mu#("1"7"7Ta, 7/2"+)"+=2.250(45)#mu# sub(N). These values of the magnetic moments are discussed in the framework of the rotational model. (author).

208

Optical Feshbach Resonances in Alkaline Earth Atoms  

Science.gov (United States)

Recent proposals have shown that a quantum degenerate gas of alkaline earth atoms can be used for a number of novel quantum computing and quantum simulation experiments. Strontium is a good candidate for such experiments because it can be controlled with high precision, as demonstrated in recent atomic clock experiments. Unfortunately, the small scattering length of strontium is not amenable to evaporative cooling techniques that are used to reach quantum degeneracy. Furthermore, increasing the scattering length of alkaline earths with a magnetic Feshbach resonance is not possible due to their spinless electronic ground state configuration. However, recent theoretical and experimental work suggests the possibility of changing scattering lengths in alkaline earths with laser light. Using this optical Feshbach resonance near strontium's narrow ^1S0->^3P1 intercombination transition might allow its scattering length to be ...

2009-10-01

209

Multilayer structures with giant magnetoresistance  

International Nuclear Information System (INIS)

The phenomenological description of the giant magnetoresistance effect as well as discussion of the requirements which must be fulfilled in giant magnetoresistance thin film structures are given in the first part of our review. In the second part the magnetization reversal and giant magnetoresistance effect of antiferromagnetically coupled multilayers, spin Valve and pseudo-spin valve thin film structures are explained. For these structures we also discuss the influence of the structure defects such as surface roughness and pinholes on the giant magnetoresistance effect. (author)

2001-09-23

210

Domain wall pining in a jointed ferromagnetic nano-wire  

Energy Technology Data Exchange (ETDEWEB)

The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.

2004-05-01

211

Gamma irradiation induced damage creation on the cation distribution, structural and magnetic properties in Ni-Zn ferrite  

International Nuclear Information System (INIS)

Ferrite of system, namely Ni_1_-_xZn_xFe_2O_4 with x = (0.0, 0.2, 0.4, 0.6, 0.8, 1.0), have been prepared by solid state reaction to investigate the effect of gamma rays irradiations using Co"6"0 source on the cation distribution, structural and magnetic properties. The unirradiated and irradiated samples were then subjected to characterization techniques such as X-ray diffraction, magnetization and AC susceptibility. The results of these characterizations are found to be different for irradiated from that of the pristine sample. The modifications in respect of irradiated samples are explained in terms of the ion-induced disorder. The important result of #gamma#-irradiation on the cation distribution, structural and magnetic properties is the change of ratio Fe"2"+/Fe"3"+. Possible reasons on the results are proposed.

2010-09-01

212

Electronic structure of p-type (Ga,Fe)N diluted magnetic semiconductors  

Energy Technology Data Exchange (ETDEWEB)

By ab-initio calculation we show that the (Ga,Fe)N ground state may be changed from anti-ferromagnetic to ferromagnetic by acceptor defect like Ga vacancies. The electronic structures are calculated by using the Korringa-Kohn-Rostoker (KKR) method combined with coherent potential approximation (CPA). We show that we can increase the magnetic moment of Fe in p-type GaN by oxygen co-doping. Mechanism of exchange interactions between magnetic ions in p-type (Ga,Fe)N is also studied. The effect of external magnetic field on the electronic structure of (Ga, Fe)N and p-type (Ga, Fe)N is investigated.

2009-08-15

213

DFT study of structure?properties correlations in [MnTPP][TCNE] quasi-one-dimensional molecular magnets  

British Library Electronic Table of Contents (United Kingdom)

We report the first band structure calculations of the quasi-one-dimensional [MnTPP][TCNE] compounds (TPP?=?meso-tetraphenylporphyrinato, TCNE?=?tetracyanoethylene), based on Density Functional Theory (DFT) methods, in order to interpret the magnetic ordering in these prototypic systems. We compare and contrast the results of broken-symmetry DFT calculations for extended systems, with periodic boundary conditions, and for finite systems, magnetic dimers modeling the actual molecular magnets. By varying systematically the main angles, we are able to determine the geometry dependence of the exchange interaction. Structure?properties correlations in these charge-transfer salts reveal the determinant role of the Mn-(N?C)TCNE bond angle on the strength of the ferrimagnetic coupling between the ...

2011-01-01

214

Crystal structure and magnetic properties of R/sub 6/Cu/sub 8/Sn/sub 8/ compounds (R=Gd, Tb, Dy, Ho, Er, Tm)  

Energy Technology Data Exchange (ETDEWEB)

The crystal structure of R/sub 6/Cu/sub 8/Sn/sub 8/ compounds (R=Gd, Tb, Dy, Ho, Er, Tm) is determined and their magnetic susceptibility is measured in the temperature range 78-293 K. The structure of the compounds is isotypical with the Gd/sub 6/Cu/sub 8/Ge/sub 8/ type (space group Immm, Z=1). The magnetic susceptibility of the R/sub 6/Cu/sub 8/Sn/sub 8/ compounds is described by the Curie-Weiss law. Effective magnetic moments of R/sub 6/Cu/sub 8/Sn/sub 8/ compounds (R=Gd, Tb, Dy, Ho, Er, Tm) are in good agreement with theoretical values for free R/sup 3 +/ ions.

1984-09-01

215

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

216

Design of a 2 T multipole wiggler insertion device for the SRS  

International Nuclear Information System (INIS)

Two new identical insertion devices have been designed for the Daresbury SRS. They are 2T permanent-magnet multipole wigglers that will provide high flux in the X-ray region. This paper describes the magnetic and mechanical design of the arrays of steel pole pieces and permanent-magnet blocks. Also given is the engineering design of the support structure that will cope with the very large forces present while maintaining high levels of precision in gap setting and parallelism. The engineering design has been fully assessed using finite-element techniques to predict the deflections of critical parts of the structure. These two devices are due to be installed into the SRS by the end of 1998.

1998-05-01

217

Structural relaxation and crystallization in the Fe-Cr-Si-B and Fe-Cu-Cr-Si-B amorphous alloys  

International Nuclear Information System (INIS)

Structural relaxation, crystallization and optimisation processes in soft magnetic amorphous alloys based on iron are examined by applying different experimental techniques: X-ray diffraction analysis, high-resolution electron microscopy, measurements of magnetic and electric properties (permeability, after-effect resistivity). The presented results are discussed in terms of annealing out of microvoids, formation of nanocrystalline phase and changes of effective magnetostriction constant. (author)

2001-09-23

218

Magnetic domains in martensite of Ni-Mg-Ga alloy  

International Nuclear Information System (INIS)

The structural changes attendant on intermartensitic transformation in a Ni-Mg-Ga shape memory alloy are considered using magneto-optical visualization with the help of ferrite-garnet monocrystalline films. It is established that on the intermartensitic transformation the complete reorganization of martensite macrostructure fails. Martensite crystals resulted from the basic transformation change somewhat their sizes on intermartensitic transition. The existence of large-scale labyrinth magnetic domain structure is revealed

2006-05-01

219

Domain structure of ferrite-garnet crystalline plates (111) with uniaxial anisotropy  

Energy Technology Data Exchange (ETDEWEB)

Magnetic field, thickness and magnetic forming effect on general mode and quantitative parameters of the domain structure (DS) of ferrite-garnet (EuEr)/sub 3/(FeGa)/sub 5/O/sub 12/ monocrystalline plates (111) is investigated. Field interval of circle (cone) and ring domain stability is determined. It is shown that DS of ferrite-garnet crystals with uniaxial an6sotropy has some peculiarities, that can be explained by cubic anisotropy effect.

1982-03-01

220

Validation of the GROMOS force-field parameter set 45A3 against nuclear magnetic resonance data of hen egg lysozyme  

Energy Technology Data Exchange (ETDEWEB)

The quality of molecular dynamics (MD) simulations of proteins depends critically on the biomolecular force field that is used. Such force fields are defined by force-field parameter sets, which are generally determined and improved through calibration of properties of small molecules against experimental or theoretical data. By application to large molecules such as proteins, a new force-field parameter set can be validated. We report two 3.5 ns molecular dynamics simulations of hen egg white lysozyme in water applying the widely used GROMOS force-field parameter set 43A1 and a new set 45A3. The two MD ensembles are evaluated against NMR spectroscopic data NOE atom-atom distance bounds, {sup 3}J{sub NH{alpha}} and {sup 3}J{sub {alpha}}{sub {beta}} coupling constants, and {sup 1}5N relaxation data. It is shown that the two sets reproduce structural properties about equally well. The 45A3 ensemble fulfills the atom-atom distance bounds derived from NMR spectroscopy ...

2004-12-15

221

Deformation change in light iridium nuclei from laser spectroscopy  

International Nuclear Information System (INIS)

Laser spectroscopy measurements have been performed on neutron-deficient and stable Ir isotopes using the COMPLIS experimental setup installed at ISOLDE-CERN. The radioactive Ir atoms were obtained from successive decays of a mass-separated Hg beam deposited onto a carbon substrate after deceleration to 1kV and subsequently laser desorbed. A three-color, two-step resonant scheme was used to selectively ionize the desorbed Ir atoms. The hyperfine structure (HFS) and isotope shift (IS) of the first transition of the ionization path 5d"76s"2"4F_9_/_2#->#5d"76s6p"6F_1_1_/_2 at 351.5nm were measured for "1"8"2"-"1"8"9Ir, "1"8"6Ir"m and the stable "1"9"1","1"9"3Ir. The nuclear magnetic moments #mu#_I and the spectroscopic quadrupole moments Q_s were obtained from the HFS spectra and the change of the mean square charge radii from the IS measurements. The sign of #mu#_I was experimentally determined for the first time for the ...

2006-12-01

222

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which ...

1998-05-01

223

Quark-Hadron Duality in Spin Structure Functions $g_1^p$ and $g_1^d$  

Energy Technology Data Exchange (ETDEWEB)

New measurements of the spin structure functions of the proton and deuteron g{sub 1}{sup p}(x, Q{sup 2}) and g{sub 1}{sup d}(x, Q{sup 2}) in the nucleon resonance region are compared with extrapolations of target-mass-corrected next-to-leading-order (NLO) QCD fits to higher energy data. Averaged over the entire resonance region (W < 2 GeV), the data and QCD fits are in good agreement in both magnitude and Q{sup 2} dependence for Q{sup 2} > 1.7 GeV{sup 2}/c{sup 2}. This ''global'' duality appears to result from cancellations among the prominent ''local'' resonance regions: in particular strong {sigma}{sub 3/2} contributions in the {Delta}(1232) region appear to be compensated by strong {sigma}{sub 1/2} contributions in the resonance region centered on 1.5 GeV. These results are encouraging for the extension ...

2006-07-25

224

Acoustic metamaterials for sound focusing and confinement  

Energy Technology Data Exchange (ETDEWEB)

We give a theoretical design for a locally resonant two-dimensional cylindrical structure involving a pair of C-shaped voids in an elastic medium which we term as double 'C' resonators (DCRs) and imbedded thin stiff bars, that displays the negative refraction effect in the low frequency regime. DCRs are responsible for a low frequency band gap which hybridizes with a tiny gap associated with the presence of the thin bars. Using an asymptotic analysis, typical working frequencies are given in closed form: DCRs behave as Helmholtz resonators modeled by masses connected to clamped walls by springs on either side, while thin bars behave as a periodic bi-atomic chain of masses connected by springs. The discrete models give an accurate description of the location and width of the stop band in the case of the DCR and the first two dispersion bands for the periodic thin bars. We then combine ...

2007-11-15

225

Acoustic metamaterials for sound focusing and confinement  

International Nuclear Information System (INIS)

We give a theoretical design for a locally resonant two-dimensional cylindrical structure involving a pair of C-shaped voids in an elastic medium which we term as double 'C' resonators (DCRs) and imbedded thin stiff bars, that displays the negative refraction effect in the low frequency regime. DCRs are responsible for a low frequency band gap which hybridizes with a tiny gap associated with the presence of the thin bars. Using an asymptotic analysis, typical working frequencies are given in closed form: DCRs behave as Helmholtz resonators modeled by masses connected to clamped walls by springs on either side, while thin bars behave as a periodic bi-atomic chain of masses connected by springs. The discrete models give an accurate description of the location and width of the stop band in the case of the DCR and the first two dispersion bands for the periodic thin bars. We then combine our asymptotic ...

2007-11-01

226

Spectral properties of cylindrical quasioptical cavity resonator with random inhomogeneous side boundary.  

Science.gov (United States)

A rigorous solution for the spectrum of a quasioptical cylindrical cavity resonator with a randomly rough side boundary has been obtained. To accomplish this task, we have developed a method for the separation of variables in a wave equation, which enables one, in principle, to rigorously examine any limiting case-from negligibly weak to arbitrarily strong disorder at the resonator boundary. It is shown that the effect of disorder-induced scattering can be properly described in terms of two geometric potentials, specifically, the "amplitude" and the "gradient" potentials, which appear in wave equations in the course of conformal smoothing of the resonator boundaries. The scattering resulting from the gradient potential appears to be dominant, and its impact on the whole spectrum is governed by the unique sharpness parameter ?, the mean tangent of the asperity slope. As opposed to the resonator with bulk ...

2011-08-30

227

Low-temperature properties of ternary magnetic rare-earth transition-metal germanides with the Sc sub 5 Co sub 4 Ge sub 10 -type structure  

Energy Technology Data Exchange (ETDEWEB)

DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque ...

1988-01-01

228

Low temperature properties of ternary magnetic rare earth transition metal germanides with the Sc/sub 5/Co/sub 4/Ge/sub 10/-type structure  

Energy Technology Data Exchange (ETDEWEB)

DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the ...

1988-07-01

229

Locally resonant acoustic metamaterials with 2D anisotropic effective mass density  

British Library Electronic Table of Contents (United Kingdom)

A two-dimensional (2D) lattice model with anisotropic resonant microstructures is found to provide an anisotropic band gap structure. A 2D continuum with anisotropic effective mass density is introduced to represent this lattice system. Two methods are proposed to derive the equivalent continuum. In the first method, the effective mass density of the equivalent continuum is obtained by matching the dispersion relations for harmonic waves propagating in the principal directions. The second approach employs an approximate estimation of the effective mass density by volume-averaging an effective mass that represents the resonant microstructure. For both equivalent continuum models, the effective mass density is frequency-dependent and may become negative in certain frequency ranges. Subsequen...

2011-01-01

230

Imaging magnetic domain structure in sub-500 nm thin film elements  

Energy Technology Data Exchange (ETDEWEB)

Magnetic imaging in the transmission electron microscope (TEM) has been used to examine submicron elements with the aim of discovering down to what element size complex domain patterns can form. The elements were squares, circles, triangles, and pentagons in the size range 100{endash}500 nm and were made from 36 nm Co films or 8 nm Ni{sub 80}Fe{sub 20} (NiFe) with in-plane magnetization. The magnetic domain structures in these elements were imaged at high resolution using the differential phase contrast imaging mode in a TEM. Nonuniform magnetization structures were seen in the images. Vortices were present at remanence in all shapes of 36-nm-thick Co elements down to 100 nm size and in circular NiFe elements down to 116 nm diameter. Triangular NiFe elements did not have a vortex state at remanence, instead the magnetization curved round ...

2001-06-01

231

Effect of Ho^3^+ substitutions on the structural and magnetic properties of BaFe12O19 hexaferrites  

British Library Electronic Table of Contents (United Kingdom)

Holmium doped barium based hexaferrites BaFe12-2xHo2xO19 with (x=0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho^3^+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (Ms), remanent magnetization (Mr) and coercivity (Hc) were observed by changing Ho^3^+ content in BaFe12-2xH...

2010-01-01

232

Effect of Ho"3"+ substitutions on the structural and magnetic properties of BaFe_1_2O_1_9 hexaferrites  

International Nuclear Information System (INIS)

Holmium doped barium based hexaferrites BaFe_1_2_-_2_xHo_2_xO_1_9 with (x = 0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho"3"+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (M_s), remanent magnetization (M_r) and coercivity (H_c) were observed by changing Ho"3"+ content in BaFe_1_2_-_2_xHo_2_xO_1_9 ferrites. Coercivity ...

2010-04-09

233

Forced vibration tests on three types of embedded structures (embedment effect test on soil-structure interaction)  

International Nuclear Information System (INIS)

A series of Model Tests of Embedment Effect on Reactor Buildings has been carried out by the Nuclear Power Engineering Corporation (NUPEC), under the sponsorship of the Ministry of International Trade and Industry (MITI) of Japan. Sinusoidal forced vibration tests were carried out on three types of large-scale models to study the embedment effect on dynamic soil-structure interaction. The differences in the resonance curves and the impedance functions were discussed in relation to the vibration characteristics of the respective structures. The embedment effects on the structural responses vary according to the stiffness of the structure. The responses of the structures can be evaluated by the Axisymmetric FEM analyses. (author)

1993-08-15

234

Magnetic and structural investigation of magnetic thin films with obliquely deposited underlayers  

CERN Document Server

An in-plane uniaxial magnetic anisotropy has been observed in thin Co films normally deposited onto obliquely sputtered Ta and Pt underlayers. Associated with this anisotropy is an augmented easy axis coercivity. The in-plane easy axis is, in most cases, perpendicular to the incident deposition plane. Microstructural results indicate that grains are well connected along the magnetic easy axis but are separated by long continuous voids along the hard axis, which is ascribed to a geometric shadowing effect due to the oblique incidence deposition of the underlayer. Hence, the magnetic anisotropy mimics the film growth anisotropy. It is therefore believed that the observed magnetic properties are due to magnetostatic shape anisotropy effects. In-plane coercivity and anisotropy field are shown to increase with underlayer deposition angle, underlayer thickness and magnetic layer ...

2002-01-01

235

Quantum information processing in nanostructures[Quantum optics; Quantum computing  

Energy Technology Data Exchange (ETDEWEB)

Since information has been regarded os a physical entity, the field of quantum information theory has blossomed. This brings novel applications, such as quantum computation. This field has attracted the attention of numerous researchers with backgrounds ranging from computer science, mathematics and engineering, to the physical sciences. Thus, we now have an interdisciplinary field where great efforts are being made in order to build devices that should allow for the processing of information at a quantum level, and also in the understanding of the complex structure of some physical processes at a more basic level. This thesis is devoted to the theoretical study of structures at the nanometer-scale, 'nanostructures', through physical processes that mainly involve the solid-state and quantum optics, in order to propose reliable schemes for the processing of quantum information. Initially, the main results of quantum information ...

2002-07-01

236

Neutron diffraction and magnetization studies of pseudoternary HoRh_2_-_xPd_xSi_2 solid solutions (0#<=#x<2)  

International Nuclear Information System (INIS)

Neutron powder diffraction and magnetometric studies of the HoRh_2_-_xPd_xSi_2 series of solid solutions (x=0, 0.5, 0.75, 1.0, 1.5, 1.8) are reported. The intermetallics investigated crystallize in the body-centred-tetragonal ThCr_2Si_2-type structure (space group I4/mmm). All the samples order antiferromagnetically at low temperatures. For low values of the dilution parameter x a simple collinear antiferromagnetic structure of the AFI type is stable. Below T_N the magnetic moments are parallel to the c-axis and then, below T_t, deflect forming an angle #psi# with the c-axis. Further replacement of Rh by Pd results in the development of a sine-wave-modulated magnetic structure with one two-component propagation vector and magnetic moments in the basal plane. For x=1.8 a sine-wave-modulated structure similar to that reported for HoPd_2Si_2 ...

2002-06-03

237

Moessbauer investigation of the magnetic anisotropy and electronic structure of a metallic glass  

International Nuclear Information System (INIS)

The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).

238

Magnetism of DyPd_2Si_2 and ErPd_2Si_2  

International Nuclear Information System (INIS)

Neutron diffraction and magnetometric measurements on polycrystalline samples of DyPd_2Si_2 and ErPd_2Si_2 were carried out in the temperature range from 2 to 293 K. Both compounds show tetragonal ThCr_2Si_2 type crystal structure and order at 12 K in a sine modulated magnetic structure with propagation vectors k=[0.609,0,0.155] and [0.575, 0, 0.083] respectively. The oscillatory character of magnetic order found in RPd_2Si_2 (R=Tb-Er) compounds suggests exchange interaction described by the RKKY model to be dominant, but the non-monotonic dependence of respective Neel temperatures on the number of f-electrons indicates the influence of a crystalline electric field (CEF) on the magnetic behaviour in this series. (orig.).

239

Magnetic properties of ErPd_2Si_2 from magnetization Moessbauer and neutron diffraction measurements  

International Nuclear Information System (INIS)

Magnetization, neutron diffraction and "1"6"6Er Moessbauer measurements on ErPd_2Si_2 are reported. Below 4.8 K ErPd_2Si_2 orders AF with complex modulated magnetic structures, where the Er moments are aligned along the c-axis. At 1.5 K a squared structure with #mu#_E_r #approx# 7.8(1)#mu#_B is found while a saturation Er moment of 8.2(2)#mu#_B is inferred from the hyperfine field data. The temperature dependence of the Moessbauer spectra in the paramagnetic region is explained in the framework of a relaxation model implying excited crystal field levels. Its analysis is used to estimate the B"m_n CEF parameters. (orig.).

240

Magnetic layer formation on plasma nitrided CoCrMo alloy  

British Library Electronic Table of Contents (United Kingdom)

In this study structural and magnetic character of the expanded austenite phase (gN) layer formed on a medical grade CoCrMo alloy by a low-pressure Radio-Frequency plasma nitriding process was investigated. The formation of the expanded austenite phase is facilitated at a substrate temperature near 400^oC for 1, 2, 4, 6 and 20h under a gas mixture of 60% N2-40% H2. The magnetic state of the gN layers was determined by a surface sensitive technique, magneto-optic Kerr effect (MOKE), and with a scanning probe microscope in magnetic force mode (MFM). Strong evidence for the ferromagnetic nature of the gN-(Co,Cr,Mo) phase is provided by the observation of stripe domain structures and the hysteresis loops. The ferromagnetic state for the gN phase observed here is mainly linked to large lattice ...

2011-01-01

241

Low-frequency fields - sources and exposure; Niederfrequente Felder - Quellen und Exposition  

Energy Technology Data Exchange (ETDEWEB)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe) [Deutsch] Nach einer kurzen Diskussion der Begriffsdefinitionen und einer Einfuehrung in die Messtechnik werden die Charakteristika verschiedener ...

1993-06-01

242

Disturbance Rejection Control of an Electromagnetic Bearing Spindle  

Energy Technology Data Exchange (ETDEWEB)

The force exerted on the rotor by an active magnetic bearing (AMB) is determined by the current flow in the magnet coils. This force can be controlled very precisely, making magnetic bearings a potential benefit for grinding, where cutting forces act as external disturbances on the shaft, resulting in degraded part finish. It is possible to achieve precise shaft positioning, reduce vibration of the shaft caused by external disturbances, and even damp out resonant modes. Adaptive control is an appealing approach for these systems because the controller can tune itself to account for an unknown periodic disturbance, such as cutting or grinding forces, injected into the system. In this paper the authors show how one adaptive control algorithm can be applied to an AMB system with a periodic disturbance applied to the rotor. An adaptive algorithm was developed and implemented in both simulation and hardware, ...

2000-08-31

243

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer ...

244

Test Bed for Superconducting Materials  

Energy Technology Data Exchange (ETDEWEB)

Superconducting rf cavities are increasingly used in accelerators. Gradient is a parameter of particular importance for the ILC. Much progress in gradient has been made over the past decade, overcoming problems of multipacting, field emission, and breakdown triggered by surface impurities. However, the quenching limit of the surface magnetic field for niobium remains a hard limitation on cavity fields sustainable with this technology. Further exploration of materials and preparation may offer a path to surpassing the current limit. For this purpose, we have designed a resonant test cavity. One wall of the cavity is formed by a flat sample of superconducting material; the rest of the cavity is copper or niobium. The H field on the sample wall is 75% higher than on any other surface. Multipacting is avoided by use of a mode with no surface electric field. The cavity will be resonated through a coupling iris with high-power rf ...

2006-01-30

245

Study of praseodymium complexing with ethylenediaminetetraacetic acid by proton magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

The method of proton magnetic resonance (PMR) has been used to study the mechanism of reaction of complexing of paramagnetic Pr/sup 3 +/ ion with ethylenediaminetetra acetic acid (EDTA). The influence of medium acidity (pH5-12), EDTA/Pr ratio varying from 1 to 50, Pr/sup 3 +/ ion concentration (from 5x10/sup -3/ to 3x10/sup -1/ g-ion/l) and temperature (8-98 deg C) on chemical shifts and broadening of signals of EDTA molecule protons is investigated. Data on ratio of components, coordination and stability of forming complexes are obtained. The existence of two types of complexes with the Pr/EDTA ratio equal to 1:1 and 1:2 has been found. Equimolecular complex (1:1) is stable all over the studied temperature interval in contrast to the complex 1:2 for which at 50 deg C fast extrasphere exchange (Pr EDTA)EDTA * + EDTA/sup 0/ reversible (PrEDTA)EDTA/sup 0/ + EDTA * is observed, while at t=98 deg C intrasphere exchange (PrEDTA)EDTA * reversible ...

1983-05-01

246

Proton magnetic resonance spectroscopy reflects cellular proliferative activity in astrocytomas  

International Nuclear Information System (INIS)

We examined whether proton magnetic resonance spectroscopy (MRS) could provide accurate information on histological grade and cell proliferation in astrocytomas. We studied 23 patients with astrocytomas: five grade II, 10 grade III and eight with grade IV (glioblastoma multiforme). We performed proton MRS and determined the Ki-67 labeling index (LI), a tumour proliferation marker, in the same areas of the astrocytomas, and examined the statistical relationship between proton MRS and Ki-67 LI. The N-acetylaspartate (NAA)/creatine-phosphocreatine (Cr) and NAA/choline (Cho)-containing compound ratios were always significantly lower and the Cho/Cr ratios significantly higher than those for normal brain. The Cho/Cr ratio correlated positively and the NAA/Cho ratio inversely with Ki-67 LI. These findings suggest that the Cho signal in proton MRS reflects cellular proliferation. In Kaplan-Meier survival analysis, there was no significant difference ...

2000-05-01

247

Monitoring of the insecticide trichlorfon by phosphorus-31 nuclear magnetic resonance ({sup 31}P NMR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Trichlorfon is an organophosphorus insecticide, which is extensively being used for protection of fruit crops. Trichlorfon is a thermal labile compound, which cannot be easily determined by gas chromatography (GC) and has no suitable group for sensitive detection by high performance liquid chromatography (HPLC). In this study, a {sup 31}P nuclear magnetic resonance ({sup 31}P NMR) has been described for monitoring of trichlorfon without any separation step. The quantitative works of {sup 31}P NMR spectroscopy has been performed in the presence of an internal standard (hexamethylphosphoramide). Limit of detection (LOD) for this method has been found to be 55 mg L{sup -1}, without any sample preparation, and the linear working range was 150-5500 mg L{sup -1}. Relative standard deviation (R.S.D.%) of the method for three replicates within and between days was obtained {<=}9%. The average recovery efficiency was approximately 99-112%. This ...

2006-08-25

248

Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)  

International Nuclear Information System (INIS)

Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...

249

Magnetic resonance imaging of the hip with a pelvic phased-array surface coil: a technical note  

Energy Technology Data Exchange (ETDEWEB)

Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer phased-array surface coils ...

1998-02-01

250

Low field magnetic resonance imaging of femoral neck fractures  

International Nuclear Information System (INIS)

Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).

251

Effect of external pH on the cytoplasmic and vacuolar pHs in Mung bean root-tip cells. A T P nuclear magnetic resonance study  

Energy Technology Data Exchange (ETDEWEB)

The effect of the external pH on the intracellular pH in mung bean (Vigna mungo (L.) Hepper) root-tip cells was investigated with the T P nuclear magnetic resonance (NMR) method. The T P NMR spectra showed three peaks caused by cytoplasmic G-6-P, cytoplasmic Psub(i) and vacuolar Psub(i). The cytoplasmic and vacuolar pHs could be determined by comparing the Psub(i) chemical shifts with the titration curve. When the external pH was changed over a range from pH 3 to 10, the cytoplasmic pH showed smaller changes than the vacuolar pH, suggesting that the former is regulated more strictly than the latter. The H -ATPase inhibitor, DCCD, caused the breakdown of the mechanism that regulates the intracellular pH. H -ATPase appears to have an important part in the regulation of the intracellular pH.

1984-12-01

252

Contrasting Kondo behavior and resonant inverse photoemission spectra of CeTSi{sub 3} and CeTGe{sub 3} (T=Rh and Ir)  

Energy Technology Data Exchange (ETDEWEB)

We have investigated CeTSi{sub 3} and CeTGe{sub 3} (T = Rh and Ir) by measuring the magnetic susceptibility, specific heat, electrical resistivity, the resonant inverse photoemission (RIPES) and M{sub IV,V} x-ray absorption spectra (XAS). The germanides showed a very weak Kondo effect, but the silicides exhibited a negatively large Weiss temperature (approx. = -130 K) and a lnT dependence of magnetic resistivity above 100 K, suggesting that they are a Kondo-lattice compound with a high Kondo temperature T{sub K} (approx. = 100 K). The Curie-Weiss law suggests that Ce atoms in these compounds remain close to 3+ down to about 150 K in spite of their high T{sub K}. In general, both RIPES and M{sub IV,V} XAS support their apparently stable valency. (author)

1999-02-28

253

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for ...

2010-10-01

254

A proton nuclear magnetic resonance investigation of the anion Bohr effect of human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution proton nuclear magnetic resonance spectroscopy has been used to investigate the molecular mechanism of the Bohr effect of human normal adult hemoglobin in the presence of two allosteric effectors, i.e., chloride and inorganic phosphate ions. The individual hydrogen ion equilibria of 22-26 histidyl residues of hemoglobin have been measured in anion-free 0.1 M HEPES buffer and in the presence of 0.18 M chloride or 0.1 M inorganic phosphate ions in both deoxy and carbonmonoxy forms. The results indicate that the #beta#2-histidyl residues are strong binding sites for chloride and inorganic phosphate ions in hemoglobin. The affinity of the #beta#2-histidyl residues for these anions is larger in the deoxy than in the carbonmonoxy form. Nevertheless, the contribution of these histidyl residues to the anion Bohr effect is small due to their low pK value in deoxyhemoglobin in anion-free solvents. The interactions of chloride and ...

255

Spontaneous and stimulated Raman studies of vibrational dephasing in condensed phases  

Energy Technology Data Exchange (ETDEWEB)

Vibrational dephasing in condensed phases is studied from both a theoretical and experimental standpoint. A theory is presented which describes the dynamics of motional or exchange processes in weakly perturbed systems. This general formalism, which has been previously used to describe motional narrowing in magnetic resonance, is applied to vibrational spectroscopy. The model treats the case of a high frequency vibration anharmonically coupled to a low-frequency vibration. Intermolecular exchange of low frequency vibrational quanta results in a temperature dependent broadening and frequency shift of the high frequency vibration. Analysis of experimental data by this model yields both the exchange rates and the anharmonic couplings.

1980-05-01

256

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

257

Quantum Computing with an Electron Spin Ensemble  

DEFF Research Database (Denmark)

We propose to encode a register of quantum bits in different collective electron spin wave excitations in a solid medium. Coupling to spins is enabled by locating them in the vicinity of a superconducting transmission line cavity, and making use of their strong collective coupling to the quantized radiation field. The transformation between different spin waves is achieved by applying gradient magnetic fields across the sample, while a Cooper pair box, resonant with the cavity field, may be used to carry out one- and two-qubit gate operations.

2009-01-01

258

Pure NQR quantum computing  

Energy Technology Data Exchange (ETDEWEB)

It is shown that pure NQR can be utilized as a platform for quantum computing without applying a high external magnetic field. By exciting each resonance transition between quadrupole energy levels with two radio-frequency fields differing in phase and direction, the double degeneracy of the spin energy spectrum in an electric field gradient is removed. As an example, in the case of I=7/2 (nuclei {sup 133}Cs or {sup 123}Sb) the energy spectrum has eight levels which can be used as three qubits. (orig.)

2002-07-01

259

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

260

Molecular accessibility in solvent swelled coal. Quarterly report  

Energy Technology Data Exchange (ETDEWEB)

To expand the information base on molecular accessibility in solvent swelled coal, Argonne Premium Coal Samples (APCS) were swelled in polar, basic solvents before and after moisture loss and upon air oxidation. So far studies have been reported on the changes in pore size distribution as a function of temperature when polar basic swelling solvents are used. Additional studies employing EPR spin probe techniques performed on the breaking up of the hydrogen bonding between bedding planes were later confirmed by magnetic resonance imaging at Argonne National Lab and the University of Illinois.

1992-11-01

261

Magnetic resonance imaging of the pediatric brain  

International Nuclear Information System (INIS)

The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.

262

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

263

IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT  

British Library Electronic Table of Contents (United Kingdom)

Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.

2011-01-01

264

Enriched lithium collection from lithium plasma flow  

International Nuclear Information System (INIS)

In order to understand the physical processes concerned with the selective heating by ion cyclotron resonance and with the subsequent collection of heated particles, experiments were carried out with the extraction of lithium samples, enriched with "6Li isotopes. Probe and integral extractors allow to collect enriched Li at the end of the selective heating region. Surface density distribution on the collector and local isotopic content of lithium are measured, as a function of the screen height and the retarding potential. Dependence of the collected amount of lithium and of its isotopic content on the value of the magnetic field is also measured. 4 figs., 2 tabs., 5 refs.

265

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

266

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

267

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.  

Science.gov (United States)

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737

2006-12-19

268

Giant magnetoresistance sensing technologies for detecting small defects in metallic structures  

Science.gov (United States)

Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.

2008-01-01

269

Structure and magnetic properties of the Al1-xGaxFeO3 family of oxides: A combined experimental and theoretical study  

International Nuclear Information System (INIS)

Magnetic properties of the Al1-xGaxFeO3 family of oxides crystallizing in a non-centrosymmetric space group have been investigated in detail along with structural aspects by employing X-ray and neutron diffraction, Moessbauer spectroscopy and other techniques. The study has revealed the occurrence of several interesting features related to unit cell parameters, site disorder and ionic size. Using first-principles density functional theory based calculations, we have attempted to understand how magnetic ordering and related properties in these oxides depend sensitively on disorder at the cation site. The origin and tendency of cations to disorder and the associated properties are traced to the local structure and ionic sizes. -- Graphical abstract: We have studied both experimentally and theoretically the important role of disorder at the cation site on magnetic and related ...

2011-03-01

270

Magnetic behavior in defect-perovskites RTa{sub 3}O{sub 9} (R=Nd,Eu and Ho)  

Energy Technology Data Exchange (ETDEWEB)

Magnetic behavior in three compounds RTa{sub 3}O{sub 9} (R = Nd, Eu and Ho) with defect-perovskite structures has been investigated by DC magnetic susceptibility. The susceptibility of NdTa{sub 3}O{sub 9} shows strong influence of crystal field. For EuTa{sub 3}O{sub 9} a typical Van Vleck paramagnetism has been observed. HoTa{sub 3}O{sub 9} obeys a Curie-Weiss law above 20 K. (orig.) 8 refs.

1998-01-01

271

Menstrual variation of breast volume and T{sub 2} relaxation times in cyclical mastalgia  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Hormonal activity causes breast volume to change during the menstrual cycle. One possible cause of this volume change is thought to be due to water retention or oedema within the tissues. We used magnetic resonance imaging (MRI) to study the variation in breast volume and {sup 1}H Magnetic Resonance Spectroscopy (MRS) to measure T{sub 2} relaxation times which are known to increase with increasing tissue water content. We hypothesised that an increase in breast volume will elevate T{sub 2} relaxation due to the presence of an increased water content within the breast. T{sub 2} Relaxation time and volume were studied in fifteen control subjects and in a cohort of eight patients with cyclical mastalgia in order to determine whether changes in breast volume and T{sub 2} relaxation times differed in controls and patients during menses, ovulation and premenses. Method: Breast volume was determined ...

2008-02-15

272

"1H and "3"1P nuclear magnetic resonance investigation of the interaction between 2,3-diphosphoglycerate and human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution "1H and "3"1P nuclear magnetic resonance spectroscopy has been used to investigate the binding of 2,3-diphosphoglycerate to human normal adult hemoglobin and the molecular interactions involved in the allosteric effect of the 2,3-diphosphoglycerate molecule on hemoglobin. Individual hydrogen ion NMR titration curves have been obtained for 22-26 histidyl residues of hemoglobin and for each phosphate group of 2,3-diphosphoglycerate with hemoglobin in both the deoxy and carbonmonoxy forms. The results indicate that 2,3-diphosphoglycerate binds to deoxyhemoglobin at the central cavity between the two #beta# chains and the binding involves the #beta#2-histidyl residues. Moreover, the results suggest that the binding site of 2,3-diphosphoglycerate to carbonmonoxyhemoglobin contains the same (or at least some of the same) amino acid residues responsible for binding in the deoxy form. As a result of the specific interactions with ...

273

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

274

Fine structure excitation transfer between the potassium 4"2P states induced by collisions with caesium atoms  

International Nuclear Information System (INIS)

Applying diode-laser resonant fluorescence method, the cross sections for the excitation energy transfer of the collisional process K"*(4"2P_1_/_2)+Cs(6"2S_1_/_2)#reversible#K"*(4"2P_3_/_2)+Cs(6"2S_1_/_2) have been measured. The values we have obtained are #sigma#(1/2#->#3/2)=77 A"2 and #sigma#(3/2#->#1/2)=48 A"2. These results complete the sequence of data for the fine-structure mixing of the first-resonance states of alkali atoms colliding with the ground-state caesium atoms. (orig.).

275

A non-uniformly sampled 4D HCC(CO)NH-TOCSY experiment processed using maximum entropy for rapid protein sidechain assignment  

Science.gov (United States)

One of the stiffest challenges in structural studies of proteins using NMR is the assignment of sidechain resonances. Typically, a panel of lengthy 3D experiments are acquired in order to establish connectivities and resolve ambiguities due to overlap. We demonstrate that these experiments can be replaced by a single 4D experiment that is time-efficient, yields excellent resolution, and captures unique carbon-proton connectivity information. The approach is made practical by the use of non-uniform sampling in the three indirect time dimensions and maximum entropy reconstruction of the corresponding 3D frequency spectrum. This 4D method will facilitate automated resonance assignment procedures and it should be particularly beneficial for increasing throughput in NMR-based structural genomics initiatives.

2010-05-01

276

Magnetization and 61Ni Moessbauer effect study of the ternary arsenide CrNiAs  

International Nuclear Information System (INIS)

The results of x-ray diffraction, dc magnetization, and 61Ni Moessbauer spectroscopy studies of the ternary arsenide CrNiAs are reported. This compound crystallizes in the orthorhombic Fe2P-type structure (space group P6-bar2m) with the lattice parameters a 6.1128(2) A and c = 3.6585(1) A. CrNiAs is a mean-field ferromagnet with Curie temperature TC = 171.9(1) K and the critical exponents ? 0.514(18), ? = 1.010(16), and ? = 2.922(10). The temperature dependence of the magnetic susceptibility above TC follows the modified Curie-Weiss law with a paramagnetic Curie temperature of 176.0(3) K and effective magnetic moment per transition metal atom of 2.42(1) ?B. The magnetic moment per formula unit at 4.2 K is found to be 1.114(33) ?B. The hyperfine magnetic field at 61Ni nuclei at 4.2 K of 41.5(1.0) kOe implies that the Ni atoms carry a magnetic ...

2008-08-13

277

Magnetic microstructure of candidates for epitaxial dual Heusler magnetic tunnel junctions  

Energy Technology Data Exchange (ETDEWEB)

Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.

2009-05-15

278

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The ...

2001-04-01

279

UAl/sub 2/: Fine structure of the f bands  

Energy Technology Data Exchange (ETDEWEB)

The electronic structure of the C15, or cubic-Laves-phase material, UAl/sub 2/ has been calculated using the linearized relativistic augmented-plane-wave method. The anomalous behavior of the electrical resistivity, specific heat, and magnetic susceptibility can be explained by the fine structure of the density of states near the Fermi energy alone, without the necessity of the introduction of drastic spin fluctuations or many-body effects.

1985-08-15

280

Time-varying magnetic fields increase cytosolic free Ca sup 2+ in HL-60 cells  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic fields have been reported to cause a variety of biological effects. It has been hypothesized that many of these phenomena are mediated by a primary effect on the concentration of cytosolic free calcium ((Ca2+)i). We investigated the effects of exposure to electromagnetic fields on (Ca2+)i in HL-60 cells using the Ca2(+)-sensitive fluorescent indicator indo-1. Indo-1-loaded cell samples were exposed to a radiofrequency electromagnetic field, a static magnetic field, and a time-varying magnetic field, which were generated by a magnetic resonance imaging (MRI) unit. We found that a 23-min exposure to all three fields, in combination, induced a significant increase in (Ca2+)i of 31 +/- 8 (SE) nM (P less than 0.01, n = 13) from a basal level of 121 +/- 8 nM. Also, cells exposed to only the time-varying magnetic field had a mean (Ca2+)i that was 34 +/- 10 nM (P less than ...

1990-10-01

281

X-point model for magnetic susceptibility of A-15 compounds  

Science.gov (United States)

The X-point linear chain model for electronic structure of A-15 compounds is shown to lead to a weakly temperature dependent magnetic susceptibility ?(T) = 3micro2?N(0) tanh (?~ / T) is serious disagreement with experiment. Supported in part by NSF-DMR76-20641; AROD-DAHCO4-75-G-0052; and FRAP-CUNY 11453.

1977-11-01

282

Spin polarization and structure of the sup(181, 182, 187)Re and "1"7"7Ta states  

International Nuclear Information System (INIS)

The properties of "1"7"7Ta and sup(181, 182, 187)Re states are discussed in the framework of the rotational model with the Coriolis coupling. The relations are obtained for calculating magnetic moments by this model in the jlK representation. The valent-nucleon spin polarization found on the basis of a comparison of the experimental values of magnetic moments with the calculated ones, is shown to depend on the number of nucleons of the same type.

1978-03-01

283

Application of a new three-dimensional k.p model for the A-15 crystals to the properties of V3 Si  

Science.gov (United States)

The new three-dimensional k.p model for the electronic structure of A-15 compounds gives satisfactory results for the magnetic susceptibility; shear modulus; tetragonal strain at the transition temperature Tm; and the magnetic field effect on Tm and shear mode sound velocity. Supported by NSF grant # DMR76-02043.

1977-11-01

284

Selected results in hadron structure from lattice QCD  

Energy Technology Data Exchange (ETDEWEB)

I present results for the mass spectrum of excited baryons and pentaquarks using overlap fermions and Bayesian curve-fitting method; and magnetic moments and polarizabilities for a variety of hadrons in the background field method.

2006-03-15

285

Selected results in hadron structure from lattice QCD  

International Nuclear Information System (INIS)

I present results for the mass spectrum of excited baryons and pentaquarks using overlap fermions and Bayesian curve-fitting method; and magnetic moments and polarizabilities for a variety of hadrons in the background field method.

2006-03-01

286

Group structure and weighting function effects on neutron penetration through thick sodium-iron shields  

Energy Technology Data Exchange (ETDEWEB)

The effects of group structures and weighting functions on neutron penetration through a thick Na-Fe geometry are studied. The recommended broad-group (61-neutron/23-gamma-ray) and few-group (22-neutron/10-gamma-ray) structures are tailored to the sodium and iron resonances, windows, and capture gamma-ray spectra. The best weighting functions are shown to be fine-group fluxes selected from a few key locations in the geometry. These group structures and weighting functions, relative to existing group structures and conventional weighting functions, improve the accuracy of the computed 61-neutron-group Bonner ball responses by up to one hundred percent and of the computed 22-neutron-group results by up to six hundred percent.

1987-01-01

287

Simulation of High Power Deposition on Target Materials: Applications in Magnetic, Inertial Fusion, and High Power Plasma Lithography Devices  

International Nuclear Information System (INIS)

High power and particle deposition on target materials are encountered in many applications including magnetic and inertial fusion devices, nuclear and high energy physics applications, and laser and discharge produced plasma devices. Surface and structural damage to plasma-facing components due to the frequent loss of plasma confinement remains a serious problem for the Tokamak reactor concept. The deposited plasma energy causes significant surface erosion, possible structural failure, and frequent plasma contamination.

2006-01-01

288

Magnetic and electrical properties of single crystalline Formula Not Shown  

British Library Electronic Table of Contents (United Kingdom)

We have successfully grown single crystalline Formula Not Shown with the range of Formula Not Shown using the floating-zone method. All compounds show orthorhombic symmetry in this substitution range, but the difference between lattice constants a and b decreases with increasing Sr concentration and becomes almost zero at Formula Not Shown . Characteristic temperatures, which correspond to antiferromagnetic ordering and structural transition, decrease with increasing Sr concentration. The value of the magnetic susceptibility below 30K increases with increasing Sr concentration. The temperature dependence of the electrical resistivity revealed that Sr substitution significantly suppresses the highly anisotropic electric structure of Formula Not Shown .

2008-01-01

289

Increase in the upper critical magnetic field in structurally inhomogeneous superconductors  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the temperature dependence of the upper critical magnetic field, Hc2(T), of structurally inhomogeneous superconductors (e.g., ternary molybdenum chalcogenides, A-15 compounds, transition metal alloys, and amorphous films) are investigated analytically. The MWGH equation for Hc2(T) is generalized to the case of weakly inhomogeneous systems with a characteristic inhomogeneity scale much smaller than the effective coherence length. It is shown that an increase in the dispersion of the diffusion coefficient leads to an increase in the slope and width of the linear section of the Hc2(T) curve. 11 references.

1987-11-01

290

Blob transport in the plasma edge. A review  

International Nuclear Information System (INIS)

A brief review is presented of transport in the boundary region of magnetized plasmas by blob-like filaments. Such structures have enhanced levels of particles and heat, are elongated along the magnetic field lines and are localized in the drift plane across the field. The motion of an isolated blob structure is described in some detail and the contribution of such filaments to turbulence-driven transport are discussed. Results are presented from numerical simulations and probe measurements in tokamak plasmas. An interpretation is given of the measured dependence of particle density and transport on experimental control parameters in the scrape-off layer. (author)

2009-05-01

291

A simple route to a tunable electromagnetic gateway  

CERN Document Server

Transformation optics is used to design a gateway that can block electromagnetic waves but allows the passage of other entities. Our conceptual device has the advantage that it can be realized with simple materials and structural parameters and can have a reasonably wide bandwidth. In particular, we show that our system can be implemented by using a magnetic photonic crystal structure that employs a square ray of ferrite rods, and as the field response of ferrites can be tuned by external magnetic fields, we end up with an electromagnetic gateway that can be open or shut using external fields. The functionality is also robust against the positional disorder of the rods that made up the photonic crystal.

2009-01-01

292

Horizontal vibration suppression method suitable for super-high-speed elevators; Chokosoku elevator ni tekishita kago yokoshindo yokusei hoshiki  

Energy Technology Data Exchange (ETDEWEB)

Horizontal vibrations of elevator cars mainly occur because a car swings as roller guides installed at corners of a car frame move on a winding guide rail at high speeds. Rider comfort in high speed elevators is worsened by these vibrations. Conventional active dampers suppressing horizontal vibrations using ac servo motors make cars heavier so driving power becomes larger, and they are not easily applied to existing elevators. An active damping control method suited to super-high-speed elevators is which can solve these problems. The method suppresses vibrations by generating only enough magnetic force needed to suppress them only when vibrations of the car franc are produced. The vibrations are detected using acceleration detectors and magnets installed on left and right sides of the car frame. A computer simulator was made to analyze phenomena of car vibrations and to verify effects of the proposed magnetic damping ...

1998-03-01

293

Spin-polarized Auger-electron diffraction study of the magnetic poisoning of Fe(001) by sulfur  

International Nuclear Information System (INIS)

Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.

294

Large Magnetic Moments of Arsenic-Doped Mn Clusters and their Relevance to Mn-Doped III-V Semiconductor Ferromagnetism  

CERN Document Server

We report electronic and magnetic structure of arsenic-doped manganese clusters from density-functional theory using generalized gradient approximation for the exchange-correlation energy. We find that arsenic stabilizes manganese clusters, though the ferromagnetic coupling between Mn atoms are found only in Mn$_2$As and Mn$_4$As clusters with magnetic moments 9 $\\mu_B$ and 17 $\\mu_B$, respectively. For all other sizes, $x=$ 3, 5-10, Mn$_x$As clusters show ferrimagnetic coupling. It is suggested that, if grown during the low temperature MBE, the giant magnetic moments due to ferromagnetic coupling in Mn$_2$As and Mn$_4$As clusters could play a role on the ferromagnetism and on the variation observed in the Curie temperature of Mn-doped III-V semiconductors.

2005-01-01

295

Effects of velocity-dependent force on the magnetic form factors of odd-Z  

International Nuclear Information System (INIS)

We investigate the effects of the velocity-dependent force on the magnetic form factors and magnetic moments of odd-Z nuclei. The form factors are calculated with the harmonic-oscillator wavefunctions. It is found that the contributions of the velocity-dependent force manifest themselves in the very large momentum transfer region (q?4 fm-1). In the low and medium q region the contributions of the velocity-dependent force are very small compared with those without this force. However, in the high-q region the contributions of the velocity-dependent force are larger than the normal form factors. The diffraction structures beyond the existing experimental data are found after the contributions of the velocity-dependent force are included. The formula of the correction to the single particle magnetic moment due to the velocity-dependent force is reproduced exactly in the long-wavelength limit (q=0) of the ...

2008-03-01

296

Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid  

CERN Document Server

In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.

1993-01-01

297

T{sub 1} and T{sub 2} relaxivities of succimer-coated MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

Energy Technology Data Exchange (ETDEWEB)

Superparamagnetic MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r{sub 2}/r{sub 1}, for MnFe{sub 2}O{sub 4}, Fe{sub 3}O{sub 4} and CoFe{sub 2}O{sub 4} were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T{sub 2} contrast agents for MRI.

2009-12-15

298

T1 and T2 relaxivities of succimer-coated MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

International Nuclear Information System (INIS)

Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.

2009-12-01

299

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

300

Remodeling of the free electron laser with the L-band linac at Osaka University  

International Nuclear Information System (INIS)

The far infrared free electron laser (FEL) has been being developed since 1990 using the L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. The first lasing was obtained in 1994 at wavelengths from 32 to 40 #mu#m. The FEL is now being modified suitable for user experiments. The wiggler with a fixed magnet gap used in the original FEL has been remodeled to make the magnet gap variable. In order to optimize the variable range of the gap, the gain and the diffraction loss were calculated. The peak gain is calculated to be 270% and the diffraction loss to be 22% at 150 #mu#m. The wavelength is expected to be variable from 25 up to at least 150 #mu#m. The two bending magnets in the optical resonator have been remodeled and the vacuum chambers with larger vertical sizes for them have been newly made so that the diffraction loss in these parts becomes smaller than ...

1997-02-28

301

Radio Frequency Plasma Applications for Space Propulsion  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ...

1999-09-13

302

High Voltage Measurements on Nine PFNs for the LHC Injection Kicker Systems  

CERN Document Server

Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions and measurements are ...

2005-01-01

303

Magnetic structures and magnetocrystalline anisotropy in bulk and thin film Fe_3Pt  

International Nuclear Information System (INIS)

Magnetic structures and magnetocrystalline anisotropy (MCA) of tetragonal phase Fe_3Pt with an L1_2 atomic ordering in bulk and thin film are investigated by means of the first-principles full-potential linearized augmented plane-wave method. The results obtained predict that the tetragonal phase, in which the tetragonal distortion with (c/a) = 0.95 makes an asymmetry of magnetic properties along the c-axis (out-of-plane) and a-axis (in-plane), has an out-of-plane MCA. In addition, from the thin film calculations, the presence of surface is found to strongly enhance the out-of-plane MCA.

2008-09-30

304

Magnetic field processing of liquid-crystalline thermosets  

Energy Technology Data Exchange (ETDEWEB)

LCTs (liquid crystal thermosets) have significant potential as a new class of structural materials. Through appropriate processing techniques using magnetic fields, the authors can orient the liquid-crystalline molecules and significantly improve the mechanical properties of the material. Most notably, the use of magnetic field processing can increase the tensile modulus threefold over the modulus in the unoriented material. This modulus value is only obtained in conventional epoxies in highly filled systems. Further investigation of the full set of mechanical properties of oriented LCTs will validate their approach to processing these materials. In the long run, the development of an economical and viable route to oriented LCTs will provide opportunities to expand the use of lightweight polymers in structural applications.

1997-08-01

305

Paramagnetic susceptibility of nonstoichiometric fluorides with the fluorite-type structure  

Energy Technology Data Exchange (ETDEWEB)

Magnetic properties of single crystals of nonstoichiometric fluorides M[sub 1-x]R[sub x]F[sub 2+x] (M = Ca, Sr, Ba; R = Ce, Pr, Nd, Gd, Ho, Er, Tm, Yb; with 0.05 [le] x [le] 0.28) with the fluorite-type structure have been studied for the first time. The magnetic susceptibility was measured using a Faraday balance in the 15-300 K temperature range. The samples are paramagnetic following the Curie-Weiss law. The values of paramagnetic Curie temperatures and effective magnetic moments of rare-earth ions have been found. Deviations of the temperature dependence of magnetic susceptibility from the Curie-Weiss law are observed for some nonstoichiometric fluorides at temperatures ranging from 60 to 85 K. Possible reaons for these deviations are discussed. Measurements of magnetic susceptibility provide an effective technique for a rapid and accurate determination of ...

1993-01-01

306

Magnetic resonance imaging of the urogenital diaphragma in comparison with conventional histomorphological findings (the controversy about the deep transverse muscle of perineum); Kernspintomographische Untersuchungen des Diaphragma urogenitale im Vergleich mit korrespondierenden histomorphologischen Befunden (der Streit um den Misculus transversus perinei profundus)  

Energy Technology Data Exchange (ETDEWEB)

The transversus perinei profundus muscle is a well known structure in found anatomical textbook. Fibres of this muscle are believed to form the so-called external urethral sphincter (musculus sphincter urethrae). Recently histomorphologic investigations have shown that there is no muscular connection between the musculus sphincter urethrae (external sphincter) and the muscle system of the pelvic floor. Furthermore, the external sphincter was found to be divided into parts: The transversely striated part (musculus sphincter urethrae transversostriatus) and the smooth part (musculus sphincter urethrae glaber). Similar to histomorphologic investigations, contrast-enhanced MR imaging has shown the musculus sphincter urethrae to be surrounded by fatty and connective tissue only. Neither in MRI nor in anatomical slices can any connection between the urethral sphincter and the muscle system of the pelvic floor be found. Thus, on the basis of the results presented in this ...

1997-01-01

307

Deformation change in light iridium nuclei from laser spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Laser spectroscopy measurements have been performed on neutron-deficient and stable Ir isotopes using the COMPLIS experimental setup installed at ISOLDE-CERN. The radioactive Ir atoms were obtained from successive decays of a mass-separated Hg beam deposited onto a carbon substrate after deceleration to 1kV and subsequently laser desorbed. A three-color, two-step resonant scheme was used to selectively ionize the desorbed Ir atoms. The hyperfine structure (HFS) and isotope shift (IS) of the first transition of the ionization path 5d{sup 7}6s{sup 24}F{sub 9/2}{yields}5d{sup 7}6s6p{sup 6}F{sub 11/2} at 351.5nm were measured for {sup 182-189}Ir, {sup 186}Ir{sup m} and the stable {sup 191,193}Ir. The nuclear magnetic moments {mu}{sub I} and the spectroscopic quadrupole moments Q{sub s} were obtained from the HFS spectra and the change of the mean square charge radii from the IS measurements. The sign of {mu}{sub I} was ...

2006-12-15

308

Spiral modes in the diffusion of a single granular particle on a vibrating surface  

International Nuclear Information System (INIS)

We consider a particle that is subject to a constant force and scatters inelastically on a vibrating periodically corrugated floor. At small friction and for small scatterers the dynamics is dominated by resonances forming spiral structures in phase space. These spiral modes lead to pronounced maxima and minima in the diffusion coefficient as a function of the vibration frequency, as is shown in computer simulations. Our theoretical predictions may be verified experimentally by studying transport of single granular particles on vibratory conveyors.

2004-11-29

309

Radiochemical and Raman spectroscopy study of the nature of adsorbed layers on a silver electrode  

International Nuclear Information System (INIS)

The structure of the layers formed on a silver electrode by the adsorption of pyridine, Cl"-, CN"- and SO_4"2"- is discussed. A comparison of the amount of the species adsorbed with their Raman spectra shows that there is no simple relation between the species concentration and the enhancement of the Raman intensity. Furthermore, the inhomogeneity of the layers is shown by Raman microscopy observations. These results lead the authors to propose the formation of a new species stabilized in the colloidal silver layer. The Raman enhancement could be explained by the existence of a resonance effect. (Auth.).

310

Quark-parton picture of the cumulative production  

International Nuclear Information System (INIS)

The quark structure of constituent nucleons is considered by a qualitative comparison of features of different models with experimental data with respect to cumulative meson production. It is shown that the fluctuation of the density of nuclear matter, ie the creation and disintegration of a short lived few-nucleon correlation (flucton), is a type of the quasi-resonance formation in the nucleus which exists without any connection with the incident particle. The cumulative production in the region under investigation is mostly the result of a Regge type dissociation of the flucton. (U.K.).

311

The accurate magnetic structure of CeAl{sub 2} at various temperatures in the ordered state  

Energy Technology Data Exchange (ETDEWEB)

The magnetic structure of the cubic compound CeAl{sub 2} is incommensurate and double-k. The moments on the two Ce sites describe two elliptical helices of opposed chiralities and lie in the (11-bar0) plane, with their Fourier components m{sup k} close to the [111] direction. Recent symmetry considerations, including for the first time the inversion center of the crystal, have reduced the number of parameters of this structure and have underlined the existence of a phase difference between the projections m{sub x}{sup k}, m{sub y}{sup k} and m{sub z}{sup k} of m{sup k}. Up to now, although many neutron investigations have been carried out on CeAl{sub 2} single crystals, no set of magnetic intensities was available which was large and good enough to check whether this phase difference exists or not. We have measured such a set of data, taking great care of the instrumental resolution in order to avoid ...

2008-04-02

312

The accurate magnetic structure of CeAl_2 at various temperatures in the ordered state  

International Nuclear Information System (INIS)

The magnetic structure of the cubic compound CeAl_2 is incommensurate and double-k. The moments on the two Ce sites describe two elliptical helices of opposed chiralities and lie in the (11-bar0) plane, with their Fourier components m"k close to the [111] direction. Recent symmetry considerations, including for the first time the inversion center of the crystal, have reduced the number of parameters of this structure and have underlined the existence of a phase difference between the projections m_x"k, m_y"k and m_z"k of m"k. Up to now, although many neutron investigations have been carried out on CeAl_2 single crystals, no set of magnetic intensities was available which was large and good enough to check whether this phase difference exists or not. We have measured such a set of data, taking great care of the instrumental resolution in order to avoid unwanted contributions to the intensities from other ...

2008-04-02

313

Ferroelectric and magnetic properties of Ho{sub 2}CuTiO{sub 6} double perovskite  

Energy Technology Data Exchange (ETDEWEB)

Ho{sub 2}CuTiO{sub 6} double pervoskite is synthesized by solid state reaction method and the phase formation was confirmed by X-ray diffraction. Ho{sub 2}CuTiO{sub 6} crystallizes in space group P63 cm and are isostructural in AMnO{sub 3} structure. We have investigated the effect of the presence of a magnetic ion (Ho{sup 3+}{approx}10.4{mu}{sub B}) in Ho{sub 2}CuTiO{sub 6}, on the magnetic properties, compared to that of an isostructural double perovskite containing Y-ion (non-magnetic), i.e., Y{sub 2}CuTiO{sub 6}. Magnetization measurements on Ho{sub 2}CuTiO{sub 6} showed paramagnetic moment of 0.026{mu}{sub B}/Ho at room temperature in an applied field of 7 T although no saturation is observed at room temperature, whereas, at 5 K, the paramagnetic moment was 0.3{mu}{sub B}/Ho in the same field. Since this compound is non-centrosymmetric, it is of interest to look into the ...

2006-08-15

314

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool for estimate the effective beam divergence are shown. Properties ...

2001-09-23

315

Experimental studies on a structure of eddy current probe for detection of magnetic flux disturbed by a flaw  

International Nuclear Information System (INIS)

Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. Nondestructive flaw ...

1995-01-01

316

Double umbrella structure in terbium iron garnet  

International Nuclear Information System (INIS)

The umbrella magnetic structure of the terbium iron garnet (TbIG) has been studied using neutron diffraction experiments peformed in the 4.2 to 650 K temperature range which covers both the Neel temperature (Tsub(N) = 550 +- 10 K) and the compensation temperature (Tsub(comp) = 244 +- 2 K). When T > Tsub(N), the observed peak intensities originate from nuclear contribution only. When Tsub(comp) < T < Tsub(N), the results have been interpreted in the Neel theory of ferrimagnetism. Below Tsub(comp), three salient features have been observed: there appears superstructure lines forbiden by the cubic space group Ia3d, whereas the other superstructure peaks are found absent contrary to other heavy rare earth garnets; the strongest reflexion (110) vanishes near Tsub(comp). The magnetic modes associated to the rhombohedral symmetry space group R(-3)c have been calculated; the two inequivalent magnetic ...

1984-04-10

317

Rocket borne solar eclipse experiment to measure the temperature structure of the solar corona via lyman-. cap alpha. line profile observations  

Energy Technology Data Exchange (ETDEWEB)

A rocket borne experiment to measure the temperature structure of the inner solar corona via the doppler broadening of the resonance hydrogen Lyman-..cap alpha.. (lambda1216A) radiation scattered by ambient neutral hydrogen atoms was attempted during the 16 Feb 1980 solar eclipse. Two Nike-Black Brant V sounding rockets carrying instrumented payloads were launched into the path of the advancing eclipse umbra from the San Marco satellite launch platform 3 miles off the east coast of Kenya.

1981-01-01

318

Recent progress of TAMA300  

International Nuclear Information System (INIS)

Current effort of the TAMA project is focused on establishment of the interferometer operation with a new vibration isolation system, called 'Seismic Attenuation System' (SAS). The SAS employs a multiple stage structure to realize soft spring for all of directions, as well as utilizes active control systems to stabilize mechanical resonances in the low frequency region below 1 Hz. The SASs were installed for four test masses, resulting in improvement of cavity length fluctuation below 150 Hz. We describe the structure of the SAS and its local active control system, and the status of the interferometer.

2008-07-01

319

Free electron laser (FEL) annealing of diamond  

International Nuclear Information System (INIS)

Free Electron Laser (FEL) with wide wavelength tunability has been developed and used for various applications. We report the structural-changes in P-ion-implanted diamond when we can achieve resonant excitation of the vibrations of specific bonds in the lattice of target (P-C) by using FEL. The change of property was analyzed by SIMS and Raman spectroscopy. After 5.8 #mu#m-FEL irradiation, we observed the crystallization of amorphous structure which was induced by P-ion-implantation. These results indicated the FEL annealing of diamond at room temperature. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

1998-09-02

320

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. ...

2000-12-01

321

The phase and pole structure of the N{sup *}(1535) in {pi}N{yields}{pi}N and {gamma}N{yields}{pi}N  

Energy Technology Data Exchange (ETDEWEB)

The nature of some baryonic resonances is still an unresolved issue. The case of the N{sup *}(1535) is particularly interesting in this respect due to the nearby {eta} N threshold and interference with the N{sup *}(1650). The N{sup *}(1535) has been described as a threshold effect, as a genuine 3-quark resonance, or as dynamically generated from the interaction of the octet of baryons with the octet of mesons. In the scheme of dynamical generation, predictions for the interaction of the N{sup *}(1535) with the photon can be made. In this study, we simultaneously analyze the role of the N{sup *}(1535) in the {pi}N{yields}{pi}N and {gamma}N{yields}{pi}N reactions and compare to the respective amplitudes from partial-wave analyses. This test is very sensitive to the meson-baryon components of the N{sup *}(1535). (orig.)

2010-01-15

322

Study of duality in the transition region at Jlab  

Energy Technology Data Exchange (ETDEWEB)

Inclusive double spin asymmetries obtained by scattering polarized electrons off polarized protons and deuterons have been analyzed to address the issue of quark-hadron duality in the polarized spin structure functions g^p_1 and g^d_1. A polarized electron beam, solid polarized NH_3 and ND_3 targets and the CEBAF Large Acceptance Spectrometer (CLAS) in Hall B were used to collect the data. The resulting g^p_1 and g^d_1 were averaged over the nucleon resonance energy region (M < W < 2.00 GeV), and three lowest lying resonances individually for tests of global and local duality.

2007-01-01

323

Structural characterization of liposomes made of diether archaeal lipids and dipalmitoyl-L-a-phosphatidylcholine  

British Library Electronic Table of Contents (United Kingdom)

The physicochemical properties of binary lipid mixtures of diether C25,25 lipids and dipalmitoyl-L-a-phosphatidylcholine (DPPC) were studied using photon correlation, fluorescence and electron paramagnetic resonance spectroscopy, and transmission electron microscopy. These two types of lipids can be mixed at all molar ratios to form unilamellar and multilamellar liposomes. Fluorescence anisotropy of 1,6-diphenyl-1,3,5-hexatrien in mixed liposomes indicates that the abrupt changes in order parameter in the hydrophobic part of bilayer membranes made of DPPC lipids disappears with increasing mol%C25,25 lipids. Electron paramagnetic resonance spectroscopy shows that at temperatures below 50^oC, the interfacial regions of membrane bilayer of mixed liposomes is more fluid than for pure DPPC lipo...

2011-01-01

324

Electron Capture Dissociation Implementation Progress in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Successful electron capture dissociation (ECD) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) applications to peptide and protein structural analysis have been enabled by constant progress in implementation of improved electron injection techniques. The rate of ECD product ion formation has been increased to match the liquid chromatography and capillary electrophoresis timescales, and ECD has been combined with infrared multiphoton dissociation in a single experimental configuration to provide simultaneous irradiation, fast switching between the two techniques, and good spatial overlap between ion, photon, and electron beams. Here we begin by describing advantages and disadvantages of the various existing electron injection techniques for ECD in FT-ICR MS. We next ...

2008-01-01

325

A sum rule approach to the violation of Dashen`s theorem; Une approache de la violation du theoreme de Dashen par les regles de somme  

Energy Technology Data Exchange (ETDEWEB)

A classic sum rule by Das et al. is extended to seven of the low-energy constant K{sub i}, introduced by Urech, which parameterizes electromagnetic corrections at chiral order O(e{sup 2}p{sup 2}). Using the spurion formalism, a simple convolution representation is shown to hold and the structure in terms of the chiral renormalization scale, QCD renormalization scale and the QED gauge parameter is displayed. The role of the resonances is studied as providing rational interpolants to relevant QCD n-point functions in the Euclidean domain. A variety of asymptotic constraints must be implemented which have phenomenological consequences. A current assumption concerning the dominance of the lowest-lying resonances is shown clearly to fail in some cases. (author)

1999-10-01

326

A non-resonant RF cavity loaded with amorphous alloy for proton cancer therapy  

CERN Document Server

A non-resonant RF cavity loaded with amorphous alloy cores has been designed and tested. The cavity has a re-entrant structure loaded with 8 amorphous alloy toroidal core and its characteristic impedance is designed as 450 Omega . The RF power is fed by 1 kW solid state amplifier using a step-up transformer with 1:9 impedance ratio. In the high power test, an accelerating gap voltage of more than 900 V was measured with input power of 1 kW in the frequency range of 1 to 10 MHz. The voltage standing wave ratio (VSWR) was less than 2.0. The results prove that the cavity may be used successfully within a compact proton synchrotron for a cancer therapy facility. (3 refs).

1999-01-01

327

Effect of magnetic field and pressure on U(Ni_1_-_xPd_x)_2Si_2 single crystals  

International Nuclear Information System (INIS)

Single crystals of U(Ni_1_-_xPd_x )_2Si_2 for x = 0.05, 0.10 and 0.15 have been grown. Magnetization and electrical resistivity measurements were performed in a wide range of temperatures, magnetic fields and high pressures in order to study stability of magnetic phases in the solid solutions between UNi_2Si_2 and UPd_2Si_2 with a special emphasis on the type of ground state. In UPd_2Si_2 the simple AFI-type antiferromagnetic structure of U moments is observed at low temperatures. UNi_2Si_2 adopts the uncompensated AF structure (UAF) with the ++- stacking of U moments along the c-axis and consequently this compound exhibits a spontaneous magnetization corresponding to 1/3 of the U moment. The substitution of Pd for Ni leads to a rapid decay of the spontaneous magnetization. The evolution of magnetization and electrical ...

2002-07-01

328

Ternary aluminides LnPd[sub 2]Al with YPd[sub 2]Si-type structure  

Energy Technology Data Exchange (ETDEWEB)

Attempts to synthesize YPd[sub 2]Si-type representatives LnPd[sub 2]Al were successful only with Ln triple bond Ce, Pr, Nd. This orthorhombic structure (oP16; space group Pnma) is an ordered variant of the Fe[sub 3]C type. Only NdPd[sub 2]Al undergoes magnetic ordering above 2 K. (orig.)

1993-04-13

329

Change of crystal field in the Er(Ni,Cu)Al system  

Energy Technology Data Exchange (ETDEWEB)

The ErNi{sub 1-} {sub x} Cu {sub x} Al compounds crystallize all in the hexagonal ZrNiAl-type structure. The concentration dependence of lattice constants shows a discontinuity between x=0.5 and 0.6. This structural change has no primary impact on the magnetic order in this series, but influences the crystal field. The lower part of the crystal-field energy-level schemes has been estimated from the specific-heat data.

2007-09-15

330

Change of crystal field in the Er(Ni,Cu)Al system  

International Nuclear Information System (INIS)

The ErNi_1_- _x Cu _x Al compounds crystallize all in the hexagonal ZrNiAl-type structure. The concentration dependence of lattice constants shows a discontinuity between x=0.5 and 0.6. This structural change has no primary impact on the magnetic order in this series, but influences the crystal field. The lower part of the crystal-field energy-level schemes has been estimated from the specific-heat data.

2007-09-01

331

Free electron laser  

International Nuclear Information System (INIS)

The present article outlines major features of the free electron laser (FEL) and reviews research and development of FEL. Relations among the oscillation frequency, electron beam parameters and wiggler parameters, the physical mechanism of amplification and the physical process of saturation are discussed to identify the difference between FEL and other lasers. The report also outlines techniques for accelerators which are used to generate high-quality, high-energy electron beams required for FEL experiments. Techniques to achieve a short wavelength, high output and high efficiency, and applications of FEL are also discussed. FEL consists of an electron accelerator, wiggler and optical resonator. In FEL, electron beams with a relativistic energy interact resonantly with an electromagnetic field to generate coherent electromagnetic waves. Unlike conventional lasers, FEL does not surfer from restrictions on its oscillation frequency associated ...

332

Preparation of Permalloy nanostructures using focused ion beam methods  

International Nuclear Information System (INIS)

Focused ion beam (FIB) milling is a powerful and versatile tool for the maskless fabrication of structures and devices at micro- and nanometer scales. The approach is based on the milling and deposition capabilities of a focused ion beam, where the latter is achieved by ion-beam-assisted decomposition of a metalorganic gas precursor of the specific material that has to be deposited. The combination of FIB and scanning electron microscopy in the same unit (so-called dual-beam unit) further expands the capabilities of the approach by the possibility of performing electron-beam-assisted deposition and inspection. Permalloy nanowires with electrical contacts patterned by FIB-Pt deposition were prepared in the dual-beam unit. Various types of notches to pin magnetic domain walls were additionally fabricated by means of FIB. The fabrication parameters for a structural modification of the Permalloy structures ...

2010-03-21

333

Development of a fine and ultra-fine group cell calculation code SLAROM-UF for fast reactor analyses  

International Nuclear Information System (INIS)

A cell calculation code SLAROM-UF has been developed for fast reactor analyses to produce effective cross sections with high accuracy in practical computing time, taking full advantage of fine and ultra-fine group calculation schemes. The fine group calculation covers the whole energy range in a maximum of 900-group structure. The structure is finer above 52.5 keV with a minimum lethargy width of 0.008. The ultra-fine group calculation solves the slowing down equation below 52.5 keV to treat resonance structures directly and precisely including resonance interference effects. Effective cross sections obtained in the two calculations are combined to produce effective cross sections over the entire energy range. Calculation accuracy and improvements from conventional 70-group cell calculation results were investigated through comparisons with reference values obtained with continuous ...

2006-08-01

334

Noncollinear magnetism in surfaces and interfaces of transition metals  

Energy Technology Data Exchange (ETDEWEB)

Noncollinear (NC) magnetism is common in nature, especially when there exist geometrical frustration and chemical imparity in the system. In this work we studied the NC magnetism and the response to external magnetic fields in surfaces and interfaces of transition metals by using an semi-empirical tight-binding (TB) method that parameterized to the ab initio TB-LMTO calculations. We implemented this method to study two systems. The first one is the system of 6 Mn monolayers on Fe(001) substrate. Due to the complex structure and magnetic properties of Mn, we found 23 collinear magnetic configurations but only one NC configuration. The collinear ground state has a layered antiferromagnetic (AFM) coupling which agrees with previous experiments and calculations. In the NC configuration the local AFM coupling in the Mn layers is preserved, but the surface is 90 ...

2009-09-15

335

Magnetism of the Ni(110) and Ni(100) surfaces: local-spin-density-functional calculations using the thin-slab linearized augmented-plane-wave method  

International Nuclear Information System (INIS)

Results of self-consistent local-spin-density-functional calculations are reported for the first time for the Ni(110) surface, represented by one-, three-, and five-layer slabs. Calculations for one- and five-layer slabs of Ni(100) are also reported. The behavior of the surface magnetization with varying slab thickness elucidates the nature and origin of the surface magnetic moment. We predict a 13% enhancement of the Ni(110) surface magnetic moment compared to the bulk value. For the Ni(100) surface, we find a smaller surface enhancement about 7%, compared to bulk, which agrees with the results of Jepsen et al. The enhancement of surface magnetic moments on Ni(100) and Ni(110) surfaces is attributed to s-d dehybridization at the surface and to the presence of electrostatic shifts required to maintain layer-by-layer charge neutrality. We find that the total d-electron charge is the same in each layer, ...

336

Input deuteron states in Mo even isotopes  

International Nuclear Information System (INIS)

An attempt is taken to explain anomalies in "9"2Mo(d, n)"9"3Tc, "9"2Mo(d, #alpha#)"9"0Nb, "9"4Mo(d, n)"9"5Tc, "9"8Mo(d, n)"9"9Tc, "9"8Mo(d, p)"9"9Mo, "9"8Mo(d, #alpha#)"9"6Nb, "1"0"0Mo(d, p)"1"0"1Mo and "1"0"0Mo(d, n)"1"0"1Tc reactions with input states having a one-particle nature. Thin films saturated with molybdenum isotopes at the approximately 1 mgxcm"-"2 surface density are used as targets. The targets are irradiated by the extracted cyclotron beam. The deuteron energy is 5-12 MeV. The reaction cross sections are determined by the activation analysis method. Quasi-stationary levels of the nucleus-deuteron system are calculated. Weak anomalies revealing in a smooth (d, #alpha#) reaction cross section on sup(92, 98)Mo nuclei, which do not necessarily correlate with anomalies in the (d, n) and (d, p) channels, are observed. The ground states of the (d, #alpha#) reaction products "9"0Nb and "9"6Nb have (8"+) and (6"+) spins, respec,.ively, that testifies to a considerable ...

337

Polarization of electron cyclotron emission spectra in LHD  

Energy Technology Data Exchange (ETDEWEB)

Electron cyclotron emission (ECE) can be used to determine the electron temperature profile in magnetized plasmas. The complex structure of the magnetic field configuration in the Large Helical Device (LHD), which has a large shear, complicates the analysis of the ECE spectrum. In a sheared magnetic field the propagation of X and O-mode polarization through the plasma are coupled, causing mode conversion and polarization rotation. Mode scrambling is also caused by wall reflections. In this report, this mode conversion in LHD is numerically analyzed. It was found that at low density mode conversion scrambles the ECE spectra. However, at higher density (n{sub eo} > 1.0{center_dot}10{sup 19} m{sup -3}) the polarization mode is found to rotate with the sheared magnetic field, yielding only a negligible mode conversion. Wall reflections are found to depolarize the ECE spectrum. ...

1999-07-01

338

New short-range electromagnetic current in the deuteron  

International Nuclear Information System (INIS)

A new model for short-range isoscalar current in the deuteron and NN system is developed and tested on a variety of isoscalar magnetic observables such as the deuteron magnetic moment, magnetic form factor, and the circular polarization of photons at n"#->#p radiative capture at thermal neutron energies. The model for electromagnetic two-nucleon current proposed in the paper is based on generation of an intermediate dibaryon in the short-range NN interaction. This intermediate dibaryon, in turn, is treated within the new model for intermediate and short-range NN interaction recently proposed by the present authors. The transition current model developed here satisfies the current conservation relation by the construction. Our calculations have demonstrated that the new current model, using only one parameter (with a clear physical meaning), is able to describe, in very good agreement with the experimental data, three ...

2007-02-01

339

Magnetic susceptibility of P{sup +}N junctions in correlation with the nature of silicon substrate: crystalline or pre-amorphised  

Energy Technology Data Exchange (ETDEWEB)

Ge pre-amorphisation step is used to reduce the high diffusivity and the transient-enhanced diffusion of boron implanted in silicon. The aim of the process is to obtain shallow P{sup +}N junctions. The pre-amorphisation step was performed under different conditions (in ambient temperature and in nitrogen). Following the rapid thermal annealing step, end of range (EOR) defects appear at the amorphous-crystalline interface. These defects could influence the electrical characteristics of the P{sup +}N junctions. An experimental study concerning three samples has been performed without and under a magnetic field of 800 G. The magnetic susceptibility was essentially observed in the case of the reverse current. The impact of the magnetic field, studied by varying the sample temperature, permits us to show an increase of the magnetic susceptibility when the defects present in such ...

2003-09-15

340

Magnetic susceptibility of P"+N junctions in correlation with the nature of silicon substrate: crystalline or pre-amorphised  

International Nuclear Information System (INIS)

Ge pre-amorphisation step is used to reduce the high diffusivity and the transient-enhanced diffusion of boron implanted in silicon. The aim of the process is to obtain shallow P"+N junctions. The pre-amorphisation step was performed under different conditions (in ambient temperature and in nitrogen). Following the rapid thermal annealing step, end of range (EOR) defects appear at the amorphous-crystalline interface. These defects could influence the electrical characteristics of the P"+N junctions. An experimental study concerning three samples has been performed without and under a magnetic field of 800 G. The magnetic susceptibility was essentially observed in the case of the reverse current. The impact of the magnetic field, studied by varying the sample temperature, permits us to show an increase of the magnetic susceptibility when the defects present in such structures are ...

2003-09-15

341

Magnetic susceptibility and "1"5"1Eu Moessbauer studies on cubic ternary compounds: EuPtSi and EuPdSi  

International Nuclear Information System (INIS)

Two new equiatomic ternary compounds, EuPtSi and EuPdSi, have been synthesized and are found to crystallize in the cubic LaIrSi type structure. The magnetic susceptibility of both compounds follows Curie-Weiss behavior in the temperature range 10 to 300 K with an effective magnetic moment close to that of Eu"2"+ moment. The paramagnetic Curie temperatures are 5 K for EuPtSi and 9 K for EuPdSi. There is no clear indication of magnetic ordering in the susceptibility of both the compounds down to 4.2 K. However, "1"5"1Eu Moessbauer studies show a hyperfine split pattern in EuPtSi at 4.2 K indicating the onset of magnetic ordering. The "1"5"1Eu isomer shifts are temperature independent and are characteristic of the divalent Eu ion. All these results establish that the Eu ions are in a stable divalent state in these compounds. (orig.).

342

Crystal electric field excitations in the cerium compound CeRh{sub 3}B{sub 2} studied by inelastic neutron scattering  

Energy Technology Data Exchange (ETDEWEB)

We have performed inelastic neutron scattering (INS) experiments on CeRh{sub 3}B{sub 2} at various temperatures to obtain direct information on the crystal electric field (CEF) in this compound, which exhibits some very peculiar magnetic properties for a Ce system: it is ferromagnetic with an unusually high Curie temperature (115 K), which contrasts with a strongly reduced and anisotropic magnetization (0.4 {mu}{sub B}/fu within the c-plane of the hexagonal structure). Measurements with high incident energies show only one well defined magnetic excitation around 150 meV, its exact position varying with the temperature. These results, combined with our previous data of magnetization and magnetic form factor, have permitted us to determine the CEF energy level scheme taking into account the two J multiplets of the Ce{sup 3+} ion. Information on the ground state ...

2007-12-19

343

Crystal electric field excitations in the cerium compound CeRh_3B_2 studied by inelastic neutron scattering  

International Nuclear Information System (INIS)

We have performed inelastic neutron scattering (INS) experiments on CeRh_3B_2 at various temperatures to obtain direct information on the crystal electric field (CEF) in this compound, which exhibits some very peculiar magnetic properties for a Ce system: it is ferromagnetic with an unusually high Curie temperature (115 K), which contrasts with a strongly reduced and anisotropic magnetization (0.4 #mu#_B/fu within the c-plane of the hexagonal structure). Measurements with high incident energies show only one well defined magnetic excitation around 150 meV, its exact position varying with the temperature. These results, combined with our previous data of magnetization and magnetic form factor, have permitted us to determine the CEF energy level scheme taking into account the two J multiplets of the Ce"3"+ ion. Information on the ground state (quasielastic ...

2007-12-19

344

Value of MRCP using oral Gd-DTPA as negative contrast materials in diagnosis of atypical juxtapapillary duodenal diverticulum  

British Library Electronic Table of Contents (United Kingdom)

Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imaging findings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...

2009-01-01

345

The role of MRI in the diagnosis of recurrent/persistent carpal tunnel syndrome: A radiological and intra-operative correlation  

British Library Electronic Table of Contents (United Kingdom)

MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...

2011-01-01

346

The influence of normal human ageing on automatic movements  

British Library Electronic Table of Contents (United Kingdom)

There is evidence that aged normal subjects have more difficulty in achieving automaticity than young subjects. The underlying central neural mechanism for this phenomenon is unclear. In the present study, functional magnetic resonance imaging (fMRI) was used to investigate the effect of normal ageing on automaticity. Aged healthy subjects were asked to practice self-initiated, self-paced, memorized sequential finger movements with different complexity until they could perform the tasks automatically. Automaticity was evaluated by having subjects perform a secondary task simultaneously with the sequential movements. Although it took more time, most aged subjects eventually performed the tasks automatically at the same level as the young subjects. Functional MRI results showed that, for bot...

2005-01-01

347

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

348

Study of the cyclotron feature in MXB 0656-072  

CERN Document Server

We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.

2006-01-01

349

Steady particulate flows in a horizontal rotating cylinder  

Energy Technology Data Exchange (ETDEWEB)

Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRI) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio {approximately}7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity field in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit. {copyright} {ital 1998 American Institute of Physics.}

1998-06-01

350

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

351

Primary and multisensory cortical activity is correlated with audiovisual percepts  

British Library Electronic Table of Contents (United Kingdom)

Incongruent auditory and visual stimuli can elicit audiovisual illusions such as the McGurk effect where visual /ka/ and auditory /pa/ fuse into another percept such as/ta/. In the present study, human brain activity was measured with adaptation functional magnetic resonance imaging to investigate which brain areas support such audiovisual illusions. Subjects viewed trains of four movies beginning with three congruent /pa/ stimuli to induce adaptation. The fourth stimulus could be (i) another congruent /pa/, (ii) a congruent /ka/, (iii) an incongruent stimulus that evokes the McGurk effect in susceptible individuals (lips /ka/ voice /pa/), or (iv) the converse combination that does not cause the McGurk effect (lips /pa/ voice/ ka/). This paradigm was predicted to show increased release fro...

2010-01-01

352

Preliminary studies on the chemical characterization and antioxidant properties of acidic polysaccharides from Sargassum fusiforme  

British Library Electronic Table of Contents (United Kingdom)

In order to investigate the antioxidant properties of the polysaccharides from the brown alga Sargassum fusiforme, the crude polysaccharides from S. fusiforme (SFPS) were extracted in hot water, and the lipid peroxidation inhibition assay exhibited that SFPS possessed a potential antioxidant activity. Hence, two purely polymeric fractions, SFPS-1 and SFPS-2 were isolated by the column of DEAE (2-diethylaminoethanol)-Sepharose Fast Flow, with their molecular weights of 51.4 and 30.3 kDa determined by high performance gel permeation chromatography (HPGPC). They were preliminarily characterized using chemical analysis in combination of infrared (IR) and nuclear magnetic resonance (NMR) spectroscopies and found to contain large amounts of uronic acids and ?-glycosidical linkages. The antioxida...

2008-01-01

353

Point defects in dilute nitride III-N-As and III-N-P  

International Nuclear Information System (INIS)

We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.

2006-04-01

354

Oxidation of polycaprolactone to induce compatibility with other degradable polyesters  

British Library Electronic Table of Contents (United Kingdom)

Chemical modification of poly(?-caprolactone) PCL by oxidation with potassium permanganate in solution was investigated. According to the data obtained from Fourier transform infrared spectroscopy (FT-IR) and nuclear magnetic resonance 1H NMR, after the oxidation reactions the PCL chains exhibited new functional groups (vinyl and hydroxyl) and possible intermolecular recombination, producing an oxidized-polycaprolactone (PCL-OX). Solution viscometry indicated that degradation also occurred during the oxidation reactions (30% drop in viscosity average molecular weight was detected). Differential scanning calorimetry (DSC) also indicated that PCL was chemically modified and degraded. The successive self-nucleation/annealing (SSA) treatment confirmed that a reduction (or interruption) in line...

2007-01-01

355

Mapping subcortical diffusivity. Application to brain development. Presidential award proceeding  

International Nuclear Information System (INIS)

We studied age-related microstructural changes in the subcortical white matter from adolescence to middle age in 16 healthy male subjects (age range: 12 to 47 years) using diffusion-weighted magnetic resonance (MR) imaging (DWI). Mean diffusivity (MD) of subcortical white matter was mapped onto the overlying cortical surface using our original method. The mean MD values within 76 cortical regions were measured using atlas-based gray matter segmentation and then correlated with age. A significant negative correlation with age was observed in subcortical MD values in several cortical regions, primarily over the bilateral temporal and occipital lobes. Our results demonstrated subcortical microstructural change in postadolescence that may reflect continuing myelination. (author)

2007-01-01

356

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

357

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

358

Influence of attention focus on neural activity in the human spinal cord during thermal sensory stimulation  

British Library Electronic Table of Contents (United Kingdom)

Perceptions of sensation and pain in healthy people are believed to be the net result of sensory input and descending modulation from brainstem and cortical regions depending on emotional and cognitive factors. Here, the influence of attention on neural activity in the spinal cord during thermal sensory stimulation of the hand was investigated with functional magnetic resonance imaging by systematically varying the participants' attention focus across and within repeated studies. Attention states included (1) attention to the stimulus by rating the sensation and (2) attention away from the stimulus by performing various mental tasks of watching a movie and identifying characters, detecting the direction of coherently moving dots within a randomly moving visual field and answering mentally-...

2011-01-01

359

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. MRI ...

2006-06-01

360

Fetal MRI of pathological brain development  

International Nuclear Information System (INIS)

Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)

2006-02-01

361

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

362

Episodic Future Thinking Reduces Reward Delay Discounting through an Enhancement of Prefrontal-Mediotemporal Interactions  

British Library Electronic Table of Contents (United Kingdom)

Summary Humans discount the value of future rewards over time. Here we show using functional magnetic resonance imaging (fMRI) and neural coupling analyses that episodic future thinking reduces the rate of delay discounting through a modulation of neural decision-making and episodic future thinking networks. In addition to a standard control condition, real subject-specific episodic event cues were presented during a delay discounting task. Spontaneous episodic imagery during cue processing predicted how much subjects changed their preferences toward more future-minded choice behavior. Neural valuation signals in the anterior cingulate cortex and functional coupling of this region with hippocampus and amygdala predicted the degree to which future thinking modulated individual preference fu...

2010-01-01

363

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

364

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

365

Early diagnosis of skeletal disorders in childhood and adolescence by MRI; Fruehdiagnose orthopaedischer Erkrankungen des Kindes- und Jugendalters mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)

1998-09-18

366

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

367

Characterization of physically vapor deposited AF2400 thin films  

Energy Technology Data Exchange (ETDEWEB)

Anti-reflective coatings made with Teflon AF2400 had the highest damage thresholds recorded for physical vapor deposited coatings at the Lawrence Livermore National Laboratory damage facility. Physical vapor deposited layers of Teflon AF2400, a perfluorinated amorphous polymer, maintained the bulk optical properties of a high transmittance from 200 nm to 1600 nm, and a low refractive index. In addition, the refractive index can be intentionally reduced by control of two common deposition parameters, deposition rate and substrate temperature. Scanning electron microscopy and nuclear magnetic resonance observations indicated that morphological changes caused the variations in the refractive index rather than compositional changes. The coatings adhered to fused silica and silicon wafers under normal laboratory handling conditions.

1993-11-01

368

Brain tumor in childhood. Hjernesvulst hos barn  

Energy Technology Data Exchange (ETDEWEB)

Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.

1990-05-01

369

Biopolymer system for permeability modification in porous media  

Energy Technology Data Exchange (ETDEWEB)

New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were ...

1995-12-31

370

Biochemical monitoring of black raspberry (Rubus coreanus Miquel) fruits according to maturation stage by ^1H NMR using multiple solvent systems  

British Library Electronic Table of Contents (United Kingdom)

Nuclear magnetic resonance (NMR) techniques coupled with multivariate data analysis were used to conduct monitoring of biochemical changes of black raspberry fruits at different stages of maturation and under various extraction and NMR dissolution solvent conditions: extraction with 50% methanol and D"2O as an NMR dissolution solvent, extraction with 50% methanol and 50% methanol-d"4 as an NMR dissolution solvent, and extraction with 100% ethyl acetate and 100% methanol-d"4 as an NMR dissolution solvent. Partial least-squares discriminant analysis reliably distinguished black raspberry fruits according to the maturation stage, whereby the relative levels of various compounds such as amino acids, organic acids, sugars and phenolic compounds were compared using analysis of variance. Sucrose ...

2011-01-01

371

Final design and manufacturing of the Cryolegs of the W7-X-superconducting coil support system  

Energy Technology Data Exchange (ETDEWEB)

One of the most complicated tasks during the assembly of the Wendelstein W7-X is the installation of the superconductive coil system. The entire magnet system is enclosed between the Outer Vessel and the plasma vessel in high vacuum at 4 K. The coils are supported by a support structure, the Central Support Structure (CSS). The CSS carries all 70 coils, and it is designed as a closed ring made of 5 modules (10 half modules). The whole structure is supported by 10 Cryolegs which rest on the machine base. This paper describes the final design and manufacture of these Cryolegs.

2008-12-15

372

A fluid structure coupling of the Ariane-5 nozzle section during start phase by detached eddy simulation  

British Library Electronic Table of Contents (United Kingdom)

Concerning the requirements of future rocket technologies, providing a cost-efficient access to orbit as well as an increase in system reliability, a deeper insight into the unsteady phenomena during ascent of modern launchers is essential. Unsteady interactions and resonances of the turbulent separated launcher wake and the nozzle structure play an important role for the design of future main stage propulsion systems. The so-called buffeting coupling phenomenon is one of the main challenges during ascent. In the present study, a coupled simulation of the afterbody of the Ariane-5 launcher with a realistic structural and aerodynamic representation of different nozzle configurations is carried out. On the computational fluid dynamics side, unsteady detached eddy simulations are coupled with...

2011-01-01

373

A Study on A Semi-Submersible Floating Offshore Wind Energy Conversion System  

Energy Technology Data Exchange (ETDEWEB)

A new semi-submersible floating structure is proposed on which three wind turbine towers are installed. This paper presents a basic characteristic of the wave-induced motion of this semi-submersible floating structure via. numerical computations and 1/150 scaled rigid model experiments in a wave tank. In the numerical computations, nonlinear damping effect due to drag forces modeled by the Morison's formula is considered in the equation of motion, where the linear hydrodynamic forces are obtained from the Green's function model. As a result, the response characteristics around the resonant frequency region were successfully improved. In addition to such basic examination, major results of feasibility studies, including the structural stability for severe wave conditions and the long-term fatigue limit state, are presented for a realistic situation.

2007-07-01

374

Microstructure Characterization of Magnetic-Pulse-Welded AA 6061-T6 by Electron Backscattered Diffraction  

Energy Technology Data Exchange (ETDEWEB)

The grain boundary crystallographic misorientations of magnetic-pulse-welded (MPW) aluminum alloy (AA) 6061-T6 in linear and tubular configurations were examined using the electron backscattered diffraction (EBSD) technique. A refined structure of heavily deformed grains with higher grain boundary angles was observed in linear welds. Significant spalling was observed away from the joints, in the interior of tubular welds. The results show the complex interaction of shock waves with the materials during this impact welding process.

2008-08-01

375

Aerial gamma ray and magnetic survey, Mississippi and Florida airborne survey: Lake Charles and Port Arthur quadrangles of Louisiana and Texas. Final report  

International Nuclear Information System (INIS)

The Lake Charles and Port Arthur quadrangles cover approximately 10,950 square miles of land west of the Mississippi River delta area. The area overlies thick sections of the Gulf of Mexico Basin. Surficial exposures are dominated by Recent and Pleistocene sediment. A search of available literature revealed no known uranium deposits. A total of 82 uranium anomalies were detected and are discussed briefly in this report. None were considered significant and all appear to relate to cultural features. Magnetic data appear to be in agreement with existing structural interpretations of the area.

376

Sterically stabilized water based magnetic fluids: Synthesis, structure and properties  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluids (MFs), prepared by chemical co-precipitation followed by double layer steric and electrostatic (combined) stabilization of magnetite nanoparticles dispersed in water, are presented. Several combinations of surfactants with different chain lengths (lauric acid (LA), myristic acid (MA), oleic acid (OA) and dodecyl-benzene-sulphonic acid (DBS)) were used, such as LA+LA, MA+MA, LA+DBS, MA+DBS, OA+DBS, OA+OA and DBS+DBS. Static light scattering, transmission electron microscopy, small angle neutron scattering, magnetic and magneto-rheological measurements revealed that MFs with MA+MA or LA+LA biocompatible double layer covered magnetite nanoparticles are the most stable colloidal systems among the investigated samples, and thus suitable for biomedical applications.

2007-04-15

377

Structure properties and magnetic susceptibility of diluted magnetic semiconductor Y_2_-_xHo_xO_3  

International Nuclear Information System (INIS)

The polycrystalline samples of Y_2_-_xHo_xO_3 (0.10#<=#x#<=#1.80) were synthesized by ceramic technology. The X-ray powder diffraction data were collected and the crystal structures were refined by the Rietveld method for the samples Y_2_-_xHo_xO_3 (x=0.00, 0.20, 0.40, 1.20, 1.80, 2.00). Holmium ions Ho"3"+ were randomly distributed over two cationic sites 8b and 24d in the space group Ia3 in all refined structures. Cation-anion-cation bonds important for superexchange interaction were determined. Magnetic susceptibility measurements were done by the Faraday method in the temperature range 290 to 620 K and a behaviour in accordance with the Curie-Weiss law was obtained. The molar Curie's constants linearly depend on concentration. The effective magnetic moments of Ho"3"+ ions were smaller than the free ion value. The Curie-Weiss paramagnetic temperatures indicated antiferromagnetic interaction. ...

1995-01-01

378

Effect of Ho{sup 3+} substitutions on the structural and magnetic properties of BaFe{sub 12}O{sub 19} hexaferrites  

Energy Technology Data Exchange (ETDEWEB)

Holmium doped barium based hexaferrites BaFe{sub 12-2x}Ho{sub 2x}O{sub 19} with (x = 0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho{sup 3+} acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (M{sub s}), remanent magnetization (M{sub r}) and coercivity (H{sub c}) were observed by changing Ho{sup 3+} content in BaFe{sub ...

2010-04-09

379

Moderately heavy, heavy-fermion compound YbPd_2Si_2 at low temperatures  

International Nuclear Information System (INIS)

The available experimental data on the specific heat, magnetic susceptibility, magnetization, valence, NMR Knight shift and relaxation rate, and the quadrupolar moment of YbPd_2Si_2 are examined within the framework of the single-ion Anderson model. Such an analysis has previously given excellent agreement between theory and experiment for numerous other light heavy-fermion compounds, where crystalline fields do not play a dominant role. For YbPd_2Si_2, substantial crystalline-field splittings make difficult a quantitative comparison with existing exact solutions of the Anderson model. Inconsistencies with the interpretation that a nearly degenerate ground quadruplet determines the low-temperature thermodynamics are pointed out. It is concluded that at least three of the four Kramers doublets participate in the low-T properties. These three doublets should have a splitting of the order of the Kondo temperature, i.e., about 100 K. A simple ...

380

Moderately heavy, heavy-fermion compound YbPd sub 2 Si sub 2 at low temperatures  

Energy Technology Data Exchange (ETDEWEB)

The available experimental data on the specific heat, magnetic susceptibility, magnetization, valence, NMR Knight shift and relaxation rate, and the quadrupolar moment of YbPd{sub 2}Si{sub 2} are examined within the framework of the single-ion Anderson model. Such an analysis has previously given excellent agreement between theory and experiment for numerous other light heavy-fermion compounds, where crystalline fields do not play a dominant role. For YbPd{sub 2}Si{sub 2}, substantial crystalline-field splittings make difficult a quantitative comparison with existing exact solutions of the Anderson model. Inconsistencies with the interpretation that a nearly degenerate ground quadruplet determines the low-temperature thermodynamics are pointed out. It is concluded that at least three of the four Kramers doublets participate in the low-{ital T} properties. These three doublets should have a splitting of the order of the Kondo temperature, i.e., ...

1992-07-01

381

Evaluation of fetal brain development by magnetic resonance imaging. Subependymal germinal matrix layer and cerebral ventricle  

International Nuclear Information System (INIS)

Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The relation between fetal ages and volume of cerebral ventricle also showed similar pattern. This method will be useful to examine the development of the ...

1999-10-01

382

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that ...

1996-01-01

383

Assembly of Linear Nano-Chains from Iron Oxide Nanospheres with Asymmetric Surface Chemistry  

Science.gov (United States)

Besides the multifunctionality, another equally important aspect of nanoparticles is their engineerability to control the geometrical and chemical properties during fabrication. In this work, we exploited this aspect to define asymmetric surface chemistry of an iron oxide nanosphere by controlling the topology of ligand expression on its surface resulting in a particle with two faces, one displaying only amines and the other only thiols. Specifically, amine-functionalized iron oxide nanospheres were attached on a solid support via a crosslinker containing a disulfide bridge. Liberation of the nanosphere using thiolytic cleavage created thiols on the portion of the particle's surface that interacted with the solid support. Employing a solid-phase strategy and a step-by-step addition of particles, the two unique faces on the same nanosphere served as fittings to assemble them into linear nano-chains. Assembly of chains with various lengths and aspect ratios was controlled by the size and ...

2011-01-06

384

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum control of the radial overlap of the laser/negative ion beam ...

2008-09-01

385

Structure and magnetic properties of RE_4CoCd and RE_4RhCd (RE = Tb, Dy, Ho)  

International Nuclear Information System (INIS)

New rare earth metal rich cadmium compounds RE_4CoCd and RE_4RhCd (RE = Tb, Dy, Ho) were prepared by high-frequency melting of the elements in sealed tantalum tubes. The samples were studied by x-ray powder and single-crystal diffraction. All the compounds crystallize with Gd_4RhIn-type structure, with space group F4-bar3m. The structures are built up from rigid three-dimensional networks of condensed, cobalt (rhodium) centred trigonal RE_6 prisms. The voids left by these networks are filled by Cd_4 cluster units and the coordination number 14 polyhedra of the RE1 atoms. The terbium and dysprosium compounds in both series undergo antiferromagnetic ordering, whereas the holmium compounds exhibit ferromagnetic ordering. The magnetic ordering in these compounds is characterized by broad peaks around the transition temperatures. The results of detailed crystallographic investigations and preliminary ...

2007-02-21

386

Negative ion source electrode  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a negative ion source electrode which can be preferably used in a neutral particle injection device using negative ions for a thermonuclear reactor. Negative ion beams are deflected to the direction opposite to the deflecting direction by magnetic fields by using an electron suppression electrode having electrode holes with the position previously displaced before negative ion beams are accelerated to have a high energy by an accelerator thereby correcting the orbit of the negative ion beams easily. In addition, since the deflection correction electrode having the electrode holes is disposed, a proper voltage is applied to the deflection correction electrode to correct the orbit of the negative ion beams conveniently. Since the deflection correction electrode has a simple structure of a thin flat plate having electrode holes, the orbit of negative ion beams can be corrected efficiently by an extremely simple ...

1997-01-17

387

Evolution of magnetic structures in the UNi{sub 2}Si{sub 2}-UPd{sub 2}Si{sub 2} system  

Energy Technology Data Exchange (ETDEWEB)

The influence of Pd-Ni substitution on the formation of magnetic phases in the tetragonal U(Ni{sub 1-x}, Pd{sub x}){sub 2}Si{sub 2} system and the concentration magnetic phase diagram are presented. A series of different substitutions was prepared and detailed studies by powder neutron diffraction were performed for x=0.25, 0.5 and 0.75. All compounds order antiferromagnetically and form ferromagnetic basal planes stacked along the c axis (q=(0,0,q{sub z}) propagation). The ground-state phase (AF3) of UNi{sub 2}Si{sub 2} is an uncompensated AF structure (++- stacking (q{sub z}=2/3)). In UPd{sub 2}Si{sub 2} the ground-state phase corresponds to the simple AF structure AF2 (+-+-(q{sub z}=1)). In solid solutions, no traces of the AF3 phase were found for x=0.25 and the ground-state powder patterns correspond to AF2 for x{>=}0.25. (orig.)

2002-07-01

388

Evolution of magnetic structures in the UNi_2Si_2-UPd_2Si_2 system  

International Nuclear Information System (INIS)

The influence of Pd-Ni substitution on the formation of magnetic phases in the tetragonal U(Ni_1_-_x, Pd_x)_2Si_2 system and the concentration magnetic phase diagram are presented. A series of different substitutions was prepared and detailed studies by powder neutron diffraction were performed for x=0.25, 0.5 and 0.75. All compounds order antiferromagnetically and form ferromagnetic basal planes stacked along the c axis (q=(0,0,q_z) propagation). The ground-state phase (AF3) of UNi_2Si_2 is an uncompensated AF structure (++- stacking (q_z=2/3)). In UPd_2Si_2 the ground-state phase corresponds to the simple AF structure AF2 (+-+-(q_z=1)). In solid solutions, no traces of the AF3 phase were found for x=0.25 and the ground-state powder patterns correspond to AF2 for x#>=#0.25. (orig.)

389

Electronic structure and nesting-driven enhancement of the RKKY interaction at the magnetic ordering propagation vector in Gd_2PdSi_3 and Tb_2PdSi_3  

International Nuclear Information System (INIS)

We present first-time measurements of the Fermi surface and low-energy electronic structure of intermetallic compounds Gd_2PdSi_3 and Tb_2PdSi_3 by means of angle-resolved photoelectron spectroscopy (ARPES). We show that the Fermi surface in both compounds consists of an electron barrel at the #GAMMA# point surrounded by spindle-shaped electron pockets originating from the same band, with the band bottom of both features lying at 0.5 eV below the Fermi level. From the experimentally measured band structure, we estimate the momentum-dependent RKKY coupling strength and demonstrate that it is peaked at the 1/2#GAMMA# K wave vector. Comparison with neutron diffraction data from the same crystals shows perfect agreement of this vector with the propagation vector of the low-temperature in-plane magnetic order, thereby demonstrating the decisive role of the Fermi surface geometry in explaining the complex ...

2009-03-22

390

Simulating physiological conditions to evaluate nanoparticles for magnetic fluid hyperthermia (MFH) therapy applications  

Energy Technology Data Exchange (ETDEWEB)

Magnetite nanoparticles with high self-heating capacity and low toxicity characteristics are a promising candidate for cancer hyperthermia treatment. In order to achieve minimum dosage to a patient, magnetic nanoparticles with high heating capacity are needed. In addition, the influence of physiological factors on the heat capacity of a material should be investigated in order to determine the feasibility. In this study, magnetite nanoparticles coated with lauric acid were prepared by co-precipitation of Fe{sup 3+}:Fe{sup 2+} in a ratio of 2:1, 5:3, 3:2, and 4:3, and the pH was controlled using NaOH. Structural and magnetization characterization by means of X-ray diffractometry (XRD) and a superconducting quantum interference device (SQUID) revealed that the main species was Fe{sub 3}O{sub 4} and further showed that most of the nanoparticles exhibited superparamagnetic properties. All of the magnetic ...

2010-01-15

391

Design of APhF-IH Linac for a Compact Medical Accelerator  

CERN Document Server

The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and ...

2003-01-01

392

Observation of two charged bottomonium-like resonances  

CERN Document Server

We report the observation of two narrow structures at 10610MeV/c^2 and 10650MeV/c^2 in the pi^{\\pm}Upsilon(nS) (n=1,2,3) and pi^{\\pm}h_b(mP) (m=1,2) mass spectra that are produced in association with a single charged pion in Upsilon(5S) decays. The measured masses and widths of the two structures averaged over the five final states are M_1=10608.4\\pm2.0MeV/c^2, Gamma_1=15.6\\pm2.5MeV and M_2=10653.2\\pm1.5MeV/c^2, Gamma_2=14.4\\pm3.2MeV. Analysis favors quantum numbers of I^G(J^P)=1^+(1^+) for both states. The results are obtained with a 121.4fb^{-1} data sample collected with the Belle detector near the Upsilon(5S) resonance, at the KEKB asymmetric-energy e+e- collider.

2011-01-01

394

Technique for the removal of electrons from an extracted, pulsed, H{sup {minus}} ion beam  

Energy Technology Data Exchange (ETDEWEB)

A small, permanent-magnet insert structure for the removal of electrons from pulsed, extracted, negative ion beams has been developed at Lawrence Berkeley National Laboratory. The device was computer modeled and designed for an extraction field strength of 3 kV/mm. The testing was carried out with a rf driven multicusp ion source optimized for the production of H{sup {minus}} ions and pulsed at a few Hz with pulse widths of several hundreds of {mu}s. It is demonstrated that the insert structure together with a collar can remove over 98{percent} of electrons from the extracted H{sup {minus}} ion beam without any significant deterioration of the H{sup {minus}} ion output. Application to other negative ion beams can be expected from this magnetic collar insert. {copyright} {ital 1996 American Institute of Physics.}

1996-10-01

395

Supersaturation of antiferromagnetically coupled multilayers: A comparative polarised neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

Reflectometric methods like polarised neutron reflectometry (PNR) and synchrotron Moessbauer reflectometry (SMR) are capable of investigating the plane-perpendicular and lateral magnetic structure of multilayers (MLs). Previously, a variety of domain formation and transformation phenomena was found and systematically studied in a Fe/Cr ML of strong antiferromagnetic coupling by PNR and SMR. Growth of the primary domains on passing the bulk-spin-flop transition was established. The domains were found to revert to their native state only in a field considerably higher than the apparent saturation field, a phenomenon referred to as the supersaturation domain memory effect (SDME). We present a comparative PNR study of two antiferromagnetically coupled Fe/Cr MLs with different magnetisation curves. We show that the distribution of the layer-layer coupling rather than the magnetic structure of the Cr spacer ...

2007-07-15

396

Saturation of relativistic Weibel instability and the formation of stationary current sheets in collisionless plasma  

International Nuclear Information System (INIS)

We have studied the features of formation and the possible stationary structures of a self-consistent magnetic field in a relativistic collisionless plasma, which are characteristic of a simple geometry of the Weibel instability that is well known in the nonrelativistic case. The universal condition is established, the growth rate is determined, and the criteria of saturation of the Weibel instability are analyzed for a broad class of anisotropic particle distribution functions (for definiteness, in application to an electron-positron plasma). A nonlinear equation of the Grad-Shafranov type describing the potential current structures is derived and its solutions are analytically studied. Special attention is paid to spatially harmonic, nonlinear current configurations with parameters determined by the properties of the initial homogeneous plasma subject to the Weibel instability. It is demonstrated that the ...

2008-12-01

397

Interfacial ultrafine-grained structures on aluminum alloy 6061 joint and copper alloy 110 joint fabricated by magnetic pulse welding  

British Library Electronic Table of Contents (United Kingdom)

Magnetic pulse welding is a solid state impact welding process, similar to explosive welding, which produces metallurgical bond by oblique high-speed impact between two metal bodies. This violent impact removes the metal surface oxide layers and then joins the two atomic level clean metal surfaces together by the incidental compression pressure. The impact velocity is at 200?400?m/s and the being welded metal surface undergoes severe plastic deformation with strain rate in the order of 106?107?s?1. The ultrafine-grained structure was observed on the welded interface. This article studied two types of similar material lap joint interfaces and the base metals were aluminum alloy 6061 and copper alloy 110. Nano-indentation testing shows that the welded interfaces have significantly greater ha...

2010-01-01

398

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

399

A study on rf plasma nitriding at a constant power in different H_2-N_2 mixtures at different temperatures  

International Nuclear Information System (INIS)

Austenitic stainless steel AISI 304 has been nitrided by radio frequency (rf) plasma containing various nitrogen-hydrogen gas mixtures, in order to study the effect of hydrogen on structure and magnetic properties of the formed compound layer. The thermal temperature has been measured at the vicinity of the samples. The compound layer thus produced has been characterized using, X-ray diffractometer and vibration sample magnetometer. Providing the total pressure of nitrogen and hydrogen is held constant, the addition of hydrogen up to 50% gives new structural phases. The magnetization values of the plasma treated samples are strongly dependent on the percentage of H_2 in the gas phase. An excessive amount of hydrogen (#approx#75%) on the other hand, retards the nitriding process. The surface temperature of the sample and plasma condition is crucial factors for nitriding process.

2006-04-15

400

Study of radiation chemistry in solids using solid hydrogen  

Energy Technology Data Exchange (ETDEWEB)

Having simple and highly symmetric structure, solid hydrogen is a useful matrix on the study of radiation-chemical processes in solid phase which have been less understood in previous studies. We have found three outstanding findings: resonance effects on the tunneling reaction H+H{sub 2} {yields} H{sub 2} + H, effects of pressure on the dissociation and recombination of H{sub 2} molecules in solid hydrogen, and high-resolution ESR spectroscopy using a solid parahydrogen matrix. (author)

2002-03-01

401

Spin Duality on the Neutron (^3He)  

Energy Technology Data Exchange (ETDEWEB)

Thomas Jefferson National Accelerator Facility experiment E01-012 measured the 3He spin structure functions and virtual photon asymmetries in the resonance region in the momentum transfer range 1.0 < Q2 < 4.0 (GeV/c)2. Our date, when compared with existing deep inelastic scattering data, can be used to test quark-hadron duality in g1 and A1 for 3He and the neutron. Preliminary results for A{sub 1}{sup {sup 3}He} are presented, as well as some details about the experiment.

2007-02-01

402

Sensitivity to alpha-variation in ultracold atomic-scattering experiments  

CERN Document Server

We present numerical calculations for cesium and mercury to estimate the sensitivity of the scattering length to the variation of the fine structure constant alpha. The method used follows ideas Chin and Flambaum [Phys. Rev. Lett. 96, 230801 (2006)], where the sensitivity to the variation of the electron to proton mass ratio, beta, was considered. We demonstrate that for heavy systems, the sensitivity to variation of alpha is of the same order of magnitude as to variation of beta. Near narrow Feshbach resonances the enhancement of the sensitivity may exceed nine orders of magnitude.

2011-01-01

403

Nuclear fission  

Energy Technology Data Exchange (ETDEWEB)

V.M. STRUTINSKY's semi-classical method is the most precise to determine the energy of the different states along the fission way. The double-humped fission barrier explains fission isomerism. V.M. STRUTINSKY's barrier explains the ''intermediate structure'' observed in the cross section under the threshold; it provides also the observed effect of ''vibrational resonances'' with an interpretation. Taking an asymmetry parameter in consideration, a triple-humped fission barrier seems to be essential now for the light actinides. There is still a microscopic fission barrier to be explained.

1982-09-01

404

Local lattice structure, crystal field and energy level patterns in CsCdBr_3:Tm"3"+ crystals  

International Nuclear Information System (INIS)

In CsCdBr_3, Tm"3"+ substitutes for Cd"2"+. It predominately forms symmetric dimer centers and single-ion centers, both of trigonal symmetry. The energy level schemes of both centers were determined by EPR and site-selective laser spectroscopy. To describe the spectra term dependent crystal-field parameters were deduced on the basis of a microscopic model taking into account the local lattice deformation induced by the impurity centers and the quasi-resonant virtual scattering of intrinsic lattice excitations by the Tm"3"+ ions. (orig.)

1998-07-24

405

Free radicals and their transformations in irradiated proteins  

International Nuclear Information System (INIS)

Experimental investigation data are systematized of free radical states and processes in irradiated proteins. The investigation is performed by the radiospectral methods. Results are discussed in detail of the study of free radicals electronic structure of amino acids, peptides and proteins formed by the action of ionizing radiation. The specificity is stressed of the study of monocrystalls of these compounds by the method of electronic paramagnetic resonance. The nature is also studied of primary centres formed under the effect of radiation on biologically important compounds and their subsequent reactions in solid and liquid solutions. Ion-radical states of different functional groups of the protein molecule are studied. Prospects of the study and the role of anion-radicals in biological processes are discusses.

406

EPR power pattern analysis for cubic sites of Fe"3"+ in MgO  

International Nuclear Information System (INIS)

A complete electron paramagnetic resonance power pattern characterization of Fe"3"+ in cubic sites in presented. A one-to-one correspondence among the peaks appearing in the powder pattern and the outer fine-structure transitions (Mnot = 1/2 ) observed in the single crystal along the , , and directions is shown. It is shown that the process of mechanically grinding the single crystal to a powder (particle size approx.1--10 #mu#) does not remove the cubic symmetry sites. No axial or lower symmetry sites which may be induced by lattice distortion of the crystallites due to strain have been observed.

1984-01-01

407

Anisotropic optical absorption in quantum well wires induced by high-frequency laser fields  

British Library Electronic Table of Contents (United Kingdom)

The subband structure and optical properties of a cylindrical quantum well wire under intense non-resonant laser field are investigated by taking into account the correct dressing effect for the confinement potential. The energy levels and wave functions are calculated within the effective mass- approximation using a finite element method. It is found that the absorption coefficient and the saturation intensity are strongly affected by the laser amplitude and frequency as well as by the incident light polarization. As a key result, a large anisotropy in the linear and nonlinear optical absorptions for very intense laser field is predicted. These effects can be useful for the design of polarization sensitive devices.

2011-01-01

410

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal ...

1999-10-01

411

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...

2003-03-01

412

Magnetic resonance imaging assessment of brain maturation in preterm neonates with punctate white matter lesions  

International Nuclear Information System (INIS)

Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with 22 matched controls with a normal MR appearance. The two groups ...

2007-02-01

413

Magnetic Resonance Perfusion Imaging in Malformations of Cortical Development  

International Nuclear Information System (INIS)

Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side (rCBVRTSC and TTFMTSC) as well as those of the polymicrogyria/contralateral side ...

2007-10-01

414

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with transient ischemic attacks (TIA) and the ...

1997-05-01

415

Hilar cholangiocarcinoma: MR correlation with surgical and histological findings  

International Nuclear Information System (INIS)

Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the ...

2010-10-01

416

Functional magnetic resonance imaging of the normal and abnormal visual system in early life.  

DEFF Research Database (Denmark)

Functional magnetic resonance imaging (fMRI) in young children may provide information about the development of the visual cortex, and may have predictive value for later visual performance. The purpose of this study was to evaluate the usefulness of fMRI for examining cerebral processing of vision in very young infants and in infants with brain damage. We examined 15 preterm infants, 12 children suspected of having a cerebral visual impairment and 10 children with a normal visual system, all of whom were either spontaneously asleep or sedated with chloral hydrate. Cortical response to stroboscopic light stimulation could be demonstrated in all technically acceptable data sets from children with a post-menstrual age (PMA) of > 41 weeks, but not in younger infants. Children < 60 weeks PMA showed either a blood oxygenation level-dependent (BOLD) signal increase or decrease, while all older children showed a signal decrease. The activated ...

2000-01-01

417

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have ...

2008-04-15

418

Detection of Cholangiocarcinoma with Magnetic Resonance Spectroscopy of Bile in Patients with and without Primary Sclerosing Cholangitis  

International Nuclear Information System (INIS)

Background: Early detection of cholangiocarcinoma (CC) is very difficult, especially in patients with primary sclerosing cholangitis (PSC) who are at increased risk of developing CC. Purpose: To evaluate "1H magnetic resonance spectroscopy ("1H-MRS) of bile as a diagnostic marker for CC in patients with and without PSC. Material and Methods: The institutional review board approved the study, and all patients gave informed consent. Bile from 49 patients was sampled and investigated using "1H-MRS. MR spectra of bile samples from 45 patients (18 female; age range 22-87 years, mean age 57 years) were analyzed both conventionally and using computerized multivariate analysis. Sixteen of the patients had CC, 18 had PSC, and 11 had other benign findings. Results: The spectra of bile from CC patients differed from the benign group in the levels of phosphatidylcholine, bile acids, lipid, and cholesterol. It was possible to distinguish CC from benign ...

2008-10-01

419

Characterization of Absolute-Resonant Eddy Current Probes,  

Science.gov (United States)

... Accession Number : ADD335809. Title : Characterization of Absolute-Resonant Eddy Current Probes,. Corporate Author : ...

420

Large orbital magnetic moment and its quenching in the itinerant uranium intermetallic compounds UTGa_5 (T=Ni, Pd, Pt)  

International Nuclear Information System (INIS)

The crystal structure, lattice strain due to the antiferromagnetic ordering, and magnetic form factor in the itinerant 5f compounds UTGa_5 (T=Ni, Pd, Pt) have been studied by neutron scattering. High-resolution powder diffraction revealed that the tetragonality of the U-Ga layers increases down to the series of the transition metal element T. The integrated intensities of the antiferromagnetic reflections can be well explained with the Neel-type structure for UNiGa_5, whereas UPtGa_5 has the antiferromagnetic stacking of the ferromagnetically ordered uranium moments in the c plane. In both compounds the uranium moments orient along the c axis with moments of 0.75(5) and 0.32(5) #mu#_B for UNiGa_5 and UPtGa_5, respectively. No magnetic peak could be observed in the powder diffraction pattern of UPdGa_5 due to the small magnetic moment less than the experimental sensitivity. The ...

2003-12-01

421

The metrology of the LHC project: what news?  

Energy Technology Data Exchange (ETDEWEB)

The Large Hadron Collider (LHC), under construction at CERN, uses superconducting magnets operating at a temperature of 1.9 K to guide the circulating particles. A specific feature of the main magnets (dipoles and quadrupoles) is the two-in-one design with two magnetic channels in one common retaining structure. Indeed, the accelerator is made of two rings, mechanically linked, that have to be simultaneously aligned during the installation in the already existing LEP tunnel. The assembly tolerances of the LHC main magnets have been reconsidered to take into account the tight constraints on geometry. The dipoles are bent to follow closely the curvature of the circulating particles and to make a larger mechanical aperture available for the circulating particles. In order to minimise the geometrical errors the dipole assembly procedure is assisted by high precision survey measurements ...

1999-07-01

422

Magnetic braking in differentially rotating, relativistic stars  

International Nuclear Information System (INIS)

We study the magnetic braking and viscous damping of differential rotation in incompressible, uniform density stars in general relativity. Differentially rotating stars can support significantly more mass in equilibrium than nonrotating or uniformly rotating stars, according to general relativity. The remnant of a binary neutron star merger or supernova core collapse may produce such a 'hypermassive' neutron star. Although a hypermassive neutron star may be stable on a dynamical time scale, magnetic braking and viscous damping of differential rotation will ultimately alter the equilibrium structure, possibly leading to delayed catastrophic collapse. Here we treat the slow-rotation, weak-magnetic field limit in which E_r_o_t<magnetic energy, and W is the gravitational binding energy of the star. ...

2004-02-15

423

Epitaxial bain path in transition metals  

Energy Technology Data Exchange (ETDEWEB)

Epitaxial films grown pseudomorphically on substrates provide a way to stabilise non-equilibrium structures of materials. Obviously, there always is a certain lattice misfit between substrate and film material in its bulk equilibrium structure. In the pseudomorphic regime, this misfit can either lead to the growth of films in a strained bulk structure or even yield structures that are not stable in the bulk. Large misfits do not necessarily imply large lateral stress. Theory can help to predict e.g. geometry, stress and magnetic properties of pseusomorphically grown metal films. In this work, we considered the fcc-bcc epitaxial Bain path of 3d, 4d, and 5d transition metals, which provides a reasonable description of tetragonally distorted films on substrates. We carried out density functional calculations in the implementation of the full potential local orbital program package ...

2010-07-01

424

Magnetic properties of Pr_2PdSi_3 single crystals  

International Nuclear Information System (INIS)

Ternary R_2TSi_3 intermetallic compounds (R=Rare Earth, T=Transition Metal) with hexagonal AlB_2-type crystallographic structure are known because of their interesting physical properties. Pr_2PdSi_3 single crystals were grown by a vertical floating zone method. The compound exhibits congruent melting behavior at a liquidus temperature of about 1770 C. Single crystalline samples show a huge anisotropy at low temperatures due to the crystal electric field effect and order antiferromagnetically below the Neel temperature T_N=2.17 K. This value approximately obeys the linear de Gennes scaling for this class of compounds. The [001] orientation was identified as the magnetic easy axis at room temperature. At lower temperature (#approx#20 K) magnetic easy and hard axes interchange with each other. Two additional magnetic phase transitions were observed at temperatures below 1 K.

2010-03-21

425

Inelastic Neutron Scattering on an Mn10 Supertetrahedron: Assessment of Exchange Coupling Constants, Ferromagnetic Spin Waves and an Analogy to the Hckel Method  

British Library Electronic Table of Contents (United Kingdom)

Abstract The synthesis, crystal structure and magnetic characterisation by magnetisation and inelastic neutron scattering (INS) of a mixed-valent Mn10 supertetrahedral aggregate [MnIII6MnII4(4-O)4(3-N3)3(3-Br)(Hmpt)6(Br)]Br0.7(N3)0.3-2-MeOH-3-MeCN (1) (H3mpt=3-methylpentan-1,3,5-triol) is reported. The magnetic core of the molecule can be described as an octahedron of six S=2 MnIII ions with four faces, each capped by a S=5/2 MnII ion such as to form the supertetrahedron. Unlike most related complexes, the molecular symmetry is slightly reduced from approximately Td to C3. The magnetic data reveal a total spin of S=22 in the ground state due to ferromagnetic exchange couplings within the molecule. The combined INS and magnetic data permits the accurate determination of the exchange couplin...

2011-01-01

426

Analysis of the requirements for economic magnetic fusion  

Energy Technology Data Exchange (ETDEWEB)

A generic reactor model is used to examine the economic viability of electricity generation by magnetic fusion. The simple model uses components which are representative of those used in previous reactor studies of deuterium-tritium burning tokamaks, stellarators, bumpy tori, reverse field pinches and tandem mirrors. Conservative costing assumptions are made. The generic reactor is not a tokamak but rather it is intended to emphasize what is common to all magnetic fusion reactors. The reactor uses a superconducting toroidal coil set to produce the dominant magnetic field. To this extent it is a less good approximation to systems, such as the reversed field pinch in which the main field is produced by a plasma current. The main output of the study is the cost of electricity as a function of the weight and size of the fusion core - blanket, shield, structure and coils. The model shows that a 1200 MW/sub ...

1986-01-01

427

Use of shell model calculations in R-matrix studies of neutron-induced reactions  

Energy Technology Data Exchange (ETDEWEB)

R-matrix analyses of neutron-induced reactions for many of the lightest p-shell nuclei are difficult due to a lack of distinct resonance structure in the reaction cross sections. Initial values for the required R-matrix parameters, E,sub(lambda) and ..gamma..sub(lambdac) for states in the compound system, can be obtained from shell model calculations. In the present work, the results of recent shell model calculations for the lithium isotopes have been used in R-matrix analyses of /sup 6/Li+n and /sup 7/Li+n reactions for E sub(n) < 8 MeV. Consequences of the shell model predictions for the level structure of /sup 7/Li and /sup 8/Li on the /sup 6/Li+n and /sup 7/Li+n reaction mechanisms and cross sections are discussed.

1986-01-01

428

Quark-hadron duality in neutrino scattering  

Energy Technology Data Exchange (ETDEWEB)

We present a phenomenological model of the quark-hadron transition in neutrino-nucleon scattering. Using recently extracted weak nucleon transition form factors, we investigate the extent to which local and global quark-hadron duality is applicable in the neutrino F{sub 1}, F{sub 2} and F{sub 3} structure functions, and contrast this with duality in electron scattering. Our findings suggest that duality works relatively well for neutrino-nucleon scattering for the F{sub 2} and F{sub 3} structure functions, but not as well for F{sub 1}. We also calculate the quasi-elastic, resonance and deep inelastic contributions to the Adler sum rule, and find it to be satisfied to within 10% for 0.5 < Q{sup 2} < 2 GeV{sup 2}.

2006-07-24

429

Structure and magnetic properties of nanocrystalline Fe-Mo alloys prepared by mechanosynthesis  

International Nuclear Information System (INIS)

Nanocrystalline samples of Fe_8_0Mo_2_0 and Fe_5_0Mo_5_0 alloys were prepared by the mechanical milling method. The structure, lattice parameters, and crystallite size were determined by the X-ray diffraction. The magnetic properties of the milled products were determined by the Moessbauer spectroscopy. It was observed that in the case of the Fe_8_0Mo_2_0 alloy a solid solution of Mo in Fe was formed with the lattice parameters of the Fe increasing from 0.28659 nm to 0.29240 nm and the crystallite size decreasing from 250 nm to 20 nm. In the case of the Fe_5_0Mo_5_0 alloy there were no clear changes in values of the lattice parameters of Fe and Mo during the milling process, but the crystallite size decreased from 200 to 15 nm. Moessbauer spectra revealed different magnetic phases in the machanosynthesized Fe_Mo samples. In the case of the Fe_8_0Mo_2_0 alloy, the spectrum for the milled mixture indicated the formation of ...

2001-09-23

430

Stable atomic structure and magnetism of Pt-Cr binary surface alloys on Pt(0 0 1): First-principle calculations  

International Nuclear Information System (INIS)

The possibility of Pt-Cr surface alloys formation on Pt(0 0 1) was investigated and their magnetism was calculated by the full-potential linearized augmented plane wave (FLAPW) method with eight different atomic configurations. The most stable structure was calculated to be the Pt-segregated L1_2 ferromagnetic surface alloy. A_3B types (L1_2 or D0_2_2) were more stable compared to AB types (L1_0). It implies that the A_3B type surface alloys may be formed when depositing a monolayer of Cr on Pt(0 0 1). It was found from the total energy calculations that there exists a strong tendency of the Pt segregation. The segregation further stabilizes the surface alloy significantly. The work function of the most stable surface alloy was calculated to be 6.02 eV and the magnetic moment of the surface Cr was much enhanced to 3.3 #mu# _B. It is a quite interesting finding that the coupling between Cr and Pt atoms on the surface plane ...

2006-09-01

431

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow ...

2009-03-22

432

Nanocrystallization of soft magnetic Fe-Co-Zr-Cu-B alloys  

International Nuclear Information System (INIS)

In the present study, Fe_4_1Co_4_1 B_1_0Zr_7Cu_1 alloy has been investigated in order to evaluate its thermal stability and structure after heat treatment, as well as the impact of heat treatment on magnetic properties. X-ray diffractometry, differential scanning calorimetry, chemical composition microanalysis, transmission electron microscopy, and magnetic hysteresis loop measurement techniques were employed. The crystallization temperature of the as-quenched alloy is 490"oC (continuous heating at 5 "oC/min). The melt spun ribbon having 27 #mu#m in thickness was annealed for 1 hour at temperatures from 400 to 700 "oC. The alloy after treatment at about 550"oC underwent primary crystallization, with the average size of crystals under 20 nm. This specimen shows the coercive field of 38 A/m, as compared to about 160 A/m reported for a similar alloy (Fe_4_4Co_4_4B_4Zr_7Cu_1) with a similar structure, ...

2001-09-23

433

Microstructure and magnetic properties of nanocrystalline Fe75Si20M5 (M = Al, B, Cr) powders  

International Nuclear Information System (INIS)

Nanocrystalline Fe75Si20M5 (M = Al, B and Cr) powders were synthesized by mechanical alloying in a planetary ball mill from high purity elemental powders. Evolution of non-equilibrium solid solutions of ?-Fe[Si,(Al, B, Cr)] with a nanocrystalline structure was accompanied by the introduction of a large number of dislocation defects in the course of the milling process. Fe sites get substituted by Si and M (M = Al, B, Cr) atoms during the milling process. The structural change and the resulting disorder are reflected in the changes in the lattice parameter and average magnetic moment of the powders milled for various time periods. The effective magnetic anisotropy increases linearly with the milling time. An increase in coercivity with increasing milling time was observed which could be attributed to the introduction of dislocations and the reduction in the powder particle size during milling. The ...

2008-08-21

434

Magnetic ordering in CeM_2Si_2 (M = Ag,Au,Pd,Rh) compounds as studied by neutron diffraction  

International Nuclear Information System (INIS)

We report the results of neutron-diffraction experiments on CeM_2Si_2 (M = Ag,Au,Pd,Rh) which were performed to explore the role of valence fluctuations and 4f hybridization in the magnetic ordering of cerium compounds. All four order antiferromagnetically, the first three exhibiting structures consisting of ferromagnetic layers with moments perpendicular to the layers, which are believed to be characteristic of 4f-4f interactions mediated through hybridization with conduction electrons. CePd_2Si_2 has an anomalously small moment (0.62#mu#/sub B/) in the ordered state. CeAg_2Si_2 exhibits an incommensurate longitudinal, static magnetization wave with moment and propagation direction along the a axis. The fourth compound, CeRh_2Si_2, has the highest known transition temperature (39 K) reported for cerium ordering; it exhibits another second-order transition at 27 K to a complex commensurate structure ...

435

Magnetic ordering in CeM/sub 2/Si/sub 2/ (M = Ag,Au,Pd,Rh) compounds as studied by neutron diffraction  

Energy Technology Data Exchange (ETDEWEB)

We report the results of neutron-diffraction experiments on CeM/sub 2/Si/sub 2/ (M = Ag,Au,Pd,Rh) which were performed to explore the role of valence fluctuations and 4f hybridization in the magnetic ordering of cerium compounds. All four order antiferromagnetically, the first three exhibiting structures consisting of ferromagnetic layers with moments perpendicular to the layers, which are believed to be characteristic of 4f-4f interactions mediated through hybridization with conduction electrons. CePd/sub 2/Si/sub 2/ has an anomalously small moment (0.62..mu../sub B/) in the ordered state. CeAg/sub 2/Si/sub 2/ exhibits an incommensurate longitudinal, static magnetization wave with moment and propagation direction along the a axis. The fourth compound, CeRh/sub 2/Si/sub 2/, has the highest known transition temperature (39 K) reported for cerium ordering; it exhibits another second-order transition at 27 K to a complex ...

1984-03-01

436

Does hybrid density functional theory predict a non-magnetic ground state for ?-Pu?  

Science.gov (United States)

Hybrid density functionals, which replace a fraction of density functional theory (DFT) exchange with exact Hartree-Fock (HF) exchange, have been used to study the structural, magnetic, and electronic properties of ?-Pu. The fractions of exact Hartree-Fock exchange used were 25%, 40%, and 55%. Compared to the pure PBE functional, the lattice constants expanded with respect to the experimental value when the PBE-HF hybrid functionals were applied. For pure PBE and hybrid functionals with HF exchanges amounts of 25% and 40%, the ground state structure was anti-ferromagnetic, while for 55% HF contribution the ground state was non-magnetic. The 5f electrons tend to exhibit slight delocalization or itinerancy for the pure PBE functional and well-defined localization for the hybrid functionals, with the degree of 5f electron localization increasing with the amount of HF exchange. Overall, the performance of ...

2009-01-01

437

Does hybrid density functional theory predict a non-magnetic ground state for #delta#-Pu?  

International Nuclear Information System (INIS)

Hybrid density functionals, which replace a fraction of density functional theory (DFT) exchange with exact Hartree-Fock (HF) exchange, have been used to study the structural, magnetic, and electronic properties of #delta#-Pu. The fraction of exact Hartree-Fock exchange used were 25%, 40%, and 55%. Compared to the pure PBE functional, the lattice constants expanded with respect to the experimental value when the PBE-HF hybrid functionals were applied. For pure PBE and hybrid functionals with HF exchanges amounts of 25% and 40%, the ground state structure was anti-ferromagnetic, while for 55% HF contribution the ground state was non-magnetic. The 5f electrons tend to exhibit slight delocalization of itinerancy for the pure PBE functional and well-defined localization for the hybrid functionals, with the degree of 5f electron localization increasing with the amount of HF exchange. Overall, the performance ...

2009-01-01

438

The electronic structure of organometallic complexes of the f elements XXV. Crystal field splitting pattern of the anionic complex [Cp_3Pr. NCS]"-  

International Nuclear Information System (INIS)

The absorption, emission and magnetic circular dichroism spectra of the anionic complex (Cp_3Pr. NCS)"- were measured at room and low temperatures. On the basis of these spectra the electronic structure in the f-f range could be derived. The parameters of an empirical Hamiltonian were fitted to the experimentally determined crystal field splitting pattern. Compared with the previously examined neutral Cp_3 Pr.X complexes the quadratic crystal field parameter B_0"2 is considerably reduced.

439

HTSC devices fabricated by selective epitaxial growth  

International Nuclear Information System (INIS)

The use of a selective epitaxial growth technique for fabricating YBCO thin-film microstructures is described. No film post-deposition processing is required; hence damage to the structure is minimized. The technique is compatible with a passivation process to protect the structure without exposure to air. The microbridges, Josephson junctions and rf SQUIDs protected by an amorphous YBCO passivation have long lifetime even after severe accelerated aging tests. Rf SQUIDs fabricated by this technique show a significant reduction of low-frequency noise when operating in weak magnetic fields compared with SQUIDs fabricated by the conventional ion beam etching technique. (author)

1999-04-01

440

Annealing, lattice disorder and non-Fermi liquid behavior in UCu4Pd  

Energy Technology Data Exchange (ETDEWEB)

The magnetic and electronic properties of non-Fermi liquid UCu{sub 4Pd} depend on annealing conditions. Local structural changes due to this annealing are reported from UL{sub III}- and Pd K-edge x-ray absorption fine-structure measurements. In particular, annealing decreases the fraction of Pd atoms on nominally Cu 16e sites and the U-Cu pair-distance distribution width. This study provides quantitative information on the amount of disorder in UCu{sub 4Pd} and allows an assessment of its possible importance to the observed non-Fermi liquid behavior.

2002-07-30

441

The magnetopause  

Energy Technology Data Exchange (ETDEWEB)

A review of theoretical and observational research on the magnetopause during 1987-1990. Starting with recent work on magnetic reconnection, the review proceeds to magnetopause surface wave phenomena, including the controversy over the role of solar wind pressure pulses in the coupling process and in the mimicking of flux transfer events signatures, and finishes with the magnetopause structure and associated wave phenomena. Recent advances in computer modeling of the magnetopause and the pertinent processes are also discussed. 108 refs.

1991-01-01

442

Sputter coating of tantalum and tantalum compounds. (Latest citations from the Compendex database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the properties of tantalum and tantalum compound films formed by sputtering techniques. Topics include processes, and electrical, magnetic, and dielectric properties of the sputtered films. Tantalum compounds studied include nitrates, oxides, and aluminides. The structural properties of sputtered films are also discussed. (Contains a minimum of 105 citations and includes a subject term index and title list.)

1993-06-01

443

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

444

Properties of A-15 Superconductors with Defects  

Science.gov (United States)

It is suggested that the large reduction of the superconducting transition temperature Tc due to defects observed experimentally in some A-15 compounds is caused by smearing of a high peak in the density of states at the Fermi level. The influence of defects on other physical properties (the magnetic susceptibility ?, the elastic modulus Cs, the structural transformation temperature Tm and the electrical resistivity ?) is also discussed from the same point of view. We expect the anomalous temperature dependence of ?, Cs and ? will be suppressed by defects.

1978-05-01

445

Magnetic and transport properties of Ba_2Co_9O_1_4 and Ba_1_._9A_0_._1Co_9O_1_4 (A=La or Na)  

International Nuclear Information System (INIS)

The valence and spin-state distributions of Co ions and the complex structure of antiferromagnetic Ba_2Co_9O_1_4 have led to the suggestion that doped Ba_2Co_9O_1_4 compounds may be good thermoelectric materials. We have checked this suggestion by measuring the magnetic properties as well as the transport properties of nominal Ba_1_._9A_0_._1Co_9O_1_4 (A=La or Na). We show that although all compounds are indicated to be single phase by powder X-ray diffraction analysis, they are all p-type polaronic conductors with low mobile-hole concentrations. Magnetic-susceptibility data of the parent and La-doped compounds give evidence of a second magnetic phase with ferromagnetic order setting in below 215 K; but this second phase is not seen in the Na-doped sample. We conclude that the structure is stabilized by oxidation and that cation exolution from the Ba_2Co_9O_1_4 ...

2010-11-01

446

Local Quark-Hadron Duality and Magnetic Form Factors of Bound Proton  

International Nuclear Information System (INIS)

We discuss the consequence of local duality for elastic scattering, and derive a model-independent equation between structure functions at x ? 1 and elastic electromagnetic form factors. Then the electromagnetic form factors of proton are discussed using the quark-hadron duality theory. We also debate the form factor of proton in a bound state. It may be an effective approach to study the form factor of proton in media.

2005-08-01

447

Hyperfine anomaly measurements in francium isotopes and the radial distribution of neutrons  

International Nuclear Information System (INIS)

We have performed precision measurements in a magneto-optical trap of the 7P1/2 hyperfine structure of the isotopes 209-210Fr. The ratio of these hyperfine constants to the previously measured 7S1/2 ground state values reveals a significant hyperfine anomaly. This anomaly results from the different radial dependence of the electron density in the two atomic levels. The measurements are sensitive to changes in the radial distribution of the neutron magnetism.

1999-09-01

448

Hyperfine Interaction in USb2 Crystal  

CERN Document Server

The hyperfine interactions at the uranium site in the antiferromagnetic USb2 compound were calculated within the density functional theory (DFT) employing augmented plane wave plus local orbital (APW+lo) method. We investigated the dependence of the nuclear quadruple interaction to the magnetic structure in USb2 compound. The result shows that the 5f-electrons have the tendency to be hybridized with the conduction electrons.

2007-01-01

449

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

450

Determination of the /sup 242m/Am nuclear moments  

Energy Technology Data Exchange (ETDEWEB)

The hyperfine structure of Am atoms was investigated in an atomic beam by laser spectroscopy. The observed splittings were evaluated with respect to the magnetic dipole and electric quadrupole moments of /sup 242m/Am. The results are: ..mu../sub I/(/sup 242m/Am) = +0.97(5) nm, Q(/sup 242m/Am) = +6.5(2.0) b.

1988-07-01

451

Computer Algebra meets Finite Elements: an Efficient Implementation for Maxwell's Equations  

CERN Document Server

We consider the numerical discretization of the time-domain Maxwell's equations with an energy-conserving discontinuous Galerkin finite element formulation. This particular formulation allows for higher order approximations of the electric and magnetic field. Special emphasis is placed on an efficient implementation which is achieved by taking advantage of recurrence properties and the tensor-product structure of the chosen shape functions. These recurrences have been derived symbolically with computer algebra methods reminiscent of the holonomic systems approach.

2011-01-01

452

Cerium moment collapse in ternary silicides CePd[sub 2[minus][ital x  

Energy Technology Data Exchange (ETDEWEB)

Cerium [ital L][sub 3] XANES (x-ray-absorption near-edge-structure) spectra were analyzed to separate Ce moment contributions and mixed valence (MV) in complex magnetic silicides CePd[sub 2[minus][ital x

1994-05-01

453

Half-Heusler phase related structural perturbations near stoichiometric composition FeZnSb  

International Nuclear Information System (INIS)

Half-Heusler phases XYZ (Pearson symbol cF12) are chemically versatile and rich in physical properties. The half-Heusler phase in the Fe-Zn-Sb ternary system was reported in the year 2000. In this work, two new ternary phases are identified in the vicinity of the equiatomic composition FeZnSb in the same system: Fe1-xZnSb (tetragonal, space group P4/nmm, Pearson symbol tP6-?, Z=2: a=4.1113(6) A, c=6.0127(12) A for x=0.08 (1), and a=4.1274(6) A, c=6.0068(12) A for x=0.12 (2)); and Fe7.87Zn6.72Sb8 (Fe0.98Zn0.84Sb) (3) (cubic, space group Fm-3m, Pearson symbol cF96-?, Z=4, a=11.690(13) A). 1 and 2 crystallize in the PbFCl-type structure, and 3 adopts a unique 2x2x2 supercell of a normal half-Heusler structure. The structures of both the tetragonal and cubic phases can be described as assemblies of half-Heusler structure related subunits. Electrical resistivity measurement on the pure sample of 2 shows it ...

2011-05-01

454

NMR studies of Borrelia burgdorferi OspA, a 28 kDa protein containing a single-layer #beta#-sheet  

International Nuclear Information System (INIS)

The crystal structure of outer surface protein A (OspA) from Borrelia burgdorferi contains a single-layer #beta#-sheet connecting the N- and C-terminal globular domains. The central #beta#-sheet consists largely of polar amino acids and it is solvent-exposed on both faces, which so far appears to be unique among known protein structures. We have accomplished nearly complete backbone H, C and N and C";/H"#beta# assignments of OspA (28 kDa) using standard triple resonance techniques without perdeuteration. This was made possible by recording spectra at a high temperature (45 "oC ). The chemical shift index and "1"5N T_1/T_2 ratios show that both the secondary structure and the global conformation of OspA in solution are similar to the crystal structure, suggesting that the unique central #beta#-sheet is fairly rigid.

1998-05-01

455

Effect of Temperature on the Local Structure of Kaolinite Intercalated with Potassium Acetate  

International Nuclear Information System (INIS)

Kaolinite intercalated with potassium acetate is of great interest in the areas of environmental remediation and industrial application; however, its exact atomic structure and the changes which occur when heated have remained largely elusive. Here, neutron pair distribution function analysis is used to investigate the local structural characteristics of this complex material, revealing that hydrated potassium acetate exists as a single layer in the interlamellar spacing of kaolinite. Furthermore, the potassium ions within the intercalated complex are most likely associated with the resonance structure of the acetate molecules, and upon heating (and decomposition of the carbon containing molecules), these ions become strongly associated with the negative charge located on the oxygen atoms in the alumina layers of dehydroxylated kaolinite. Several possible orientations of hydrated potassium acetate ...

2011-01-25

456

Transformation of the ATOMKI-ECRIS into a Plasma Device  

International Nuclear Information System (INIS)

Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check the components and charge-state of the plasma. A new, large, but ...

2006-01-01

457

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

458

Size-dependent surface plasmon resonance in silver silica nanocomposites  

Energy Technology Data Exchange (ETDEWEB)

Silver silica nanocomposites were obtained by the sol-gel technique using tetraethyl orthosilicate (TEOS) and silver nitrate (AgNO{sub 3}) as precursors. The silver nitrate concentration was varied for obtaining composites with different nanoparticle sizes. The structural and microstructural properties were determined by x-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR) and transmission electron microscopy (TEM). X-ray photoelectron spectroscopic (XPS) studies were done for determining the chemical states of silver in the silica matrix. For the lowest AgNO{sub 3} concentration, monodispersed and spherical Ag crystallites, with an average diameter of 5 nm, were obtained. Grain growth and an increase in size distribution was observed for higher concentrations. The occurrence of surface plasmon resonance (SPR) bands and their evolution in the size range 5-10 nm is studied. For decreasing nanoparticle size, a redshift and ...

2008-02-20

459

Enhanced photoconductivity and fine response tuning in nanostructured porous silicon microcavities  

Energy Technology Data Exchange (ETDEWEB)

We used light confinement in optical microcavities to achieve a strong enhancement and a precise wavelength tunability of the electrical photoconductance of nanostructured porous silicon (PS). The devices consist of a periodic array of alternating PS layers, electrochemically etched to have high and low porosities - and therefore distinct dielectric functions. A central layer having a doubled thickness breaks up the symmetry of the one-dimensional photonic structure, producing a resonance in the photonic band gap that is clearly observed in the reflectance spectrum. The devices were transferred to a glass coated with a transparent SnO{sub 2} electrode, while an Al contact was evaporated on its back side. The electrical conductance was measured as a function of the photon energy. A strong enhancement of the conductance is obtained in a narrow (17nm FWHM) band peaking at the resonance. We present experimental results of the ...

2009-05-01

460

Electron spin resonance probe for the solvation of ionomer membranes and other microscopically heterogeneous systems. Cu[sup 2+] in nafion, sephadex and silica gel  

Energy Technology Data Exchange (ETDEWEB)

Cu[sup 2+] is a sensitive electron spin resonance (ESR) probe for the penetration of various polar solvents in membranes made of Nafion and as an indicator for the replacement of one solvent by another. The ESR parameters (g and [sup 63]Cu hyperfine tensors) can be translated into a structure of the solvent around the cation. The replacement of a solvent in the membrane by another depends on the polarity of the two solvents. The solvent with the largest dielectric constant, N-methylformamide (NMF), can be replaced by water but not by methanol or acetonitrile (dielectric constants 182, 78.5, 32.7, and 37.5, respectively). Preferential solvation of the cation by water in three water/acetonitrile mixtures (9:1, 1:1, and 1:9 by volume) in contact with silica gel, Sephadex, and Nafion has been observed in various degrees. Nafion is most selective, followed by Sephadex and by silica gel. The selectivity appears to be related to electrostatic ...

1992-01-01

461

Role of core toroidal rotation on the H-mode radial electric field shear, turbulence, and confinement as studied by magnetic braking in the DIII-D tokamak  

International Nuclear Information System (INIS)

''Magnetic braking'' of the plasma toroidal rotation in the high confinement H mode by applied resonant, low m,n=1 static error fields is used in DIII-D [Nucl. Fusion 31, 875 (1991)] as an independent control to evaluate the E_rxB stabilization of microturbulence in the plasma core. In the core (#rho# approx-lt 0.9) of a tokamak, the radial electric field and its shear are dominated by toroidal rotation. The fundamental quantity for shear stabilization of microturbulence is shear in the velocity of the fluctuations v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#E_rxB/B#centre dot#B which in the core is v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#v_#phi#B_#theta#/ B_#phi#. With magnetic braking greatly decreasing the toroidal rotation and thus reducing the core radial electric field and shear, far infrared (FIR) measurements of density microturbulence show downshifting in frequency near #rho##approx#0.8 as a result of the reduced Doppler shift ...

462

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.  

DEFF Research Database (Denmark)

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global stimulation, ...

2004-01-01

463

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were ...

2011-09-01

464

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

465

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

466

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

467

Single and double ionization of strontium in the vicinity of four-photon excitation of the 5p{sup 2} {sup 1}S{sub 0} doubly excited state  

Energy Technology Data Exchange (ETDEWEB)

We report on the single and double multiphoton ionization of ground state Sr atoms observed in an atomic beam experiment with laser pulses of {approx}5 ns duration, maximum intensity {approx}4 x 10{sup 11} W cm{sup -2} and within the 710-740 nm wavelength range. The Sr{sup +} spectrum consists of two strong lines originating from three-photon resonant four-photon ionization of bound states, a number of weak autoionizing resonances and a broad line due to four-photon excitation of the doubly excited 5p{sup 2} {sup 1}S{sub 0} state. The latter, along with a strong, broad and structured spectral feature, is also evident in the wavelength dependence of the doubly charged Sr{sup 2+} ion. A weakly evident but reproducible inflection point ('knee' structure) appears in the intensity dependence of the Sr{sup 2+} yield at the location of the 5p{sup 2} {sup 1}S{sub 0} ...

2008-02-28

468

TIME EVOLUTION OF CORONAL MAGNETIC HELICITY IN THE FLARING ACTIVE REGION NOAA 10930  

International Nuclear Information System (INIS)

To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through the surface. (2) The ...

2010-09-10

469

Synthesis of colloidal silver iron oxide nanoparticles--study of their optical and magnetic behavior.  

Science.gov (United States)

Silver iron oxide nanoparticles of fairly small size (average diameter approximately 1 nm) with narrow size distribution have been synthesized by the interaction of colloidal beta- Fe2O3 and silver nanoparticles. The surface morphology and size of these particles have been analyzed by using atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Their structural analysis has been carried out by employing x-ray diffraction (XRD), selected-area electron diffraction (SAED), optical and infrared (IR) spectroscopic techniques. The ageing of these particles exhibits the formation of self-assembly, possibly involving weak supramolecular interactions between Ag(I)O4 and Fe(III)O4 species. These particles display the onset of absorption in the near-infrared region and have higher absorption coefficient in the visible range compared to that of its precursors. Magnetic measurements ...

2009-07-01

470

Structure and magnetic properties of nanostructural strontium ferrite prepared by mechanochemical treatment  

International Nuclear Information System (INIS)

Full text: It was recently-established for hexagonal barium ferrite-industrially important magnetically hard material that refinement of the crystallite dimensions into the nanoscale regime, typically #<=# 10 nm, leads after heat treatment at temperatures 800-1000 deg C to significant coercivity increase of up to 6.5 kOe (#approx#3-4 times) with saturation magnetisation values of 50-55 emu/g (#approx#95% of bulk at room temperature). High-energy mechanochemical processing has been applied to prepare nanostructural (nanocrystalline-amorphous) composites. High resolution electron microscopy studies reveal that the enhancement of the final magnetic properties was due to formation of magnetically noninteracting #approx#l,#mu#m Ba-ferrite particles with 5-10 nm amorphous surface layer - depending on annealing parameters. Similar situation was established also for ball milled strontium ferrite (SrFe_1_2O_1_9) powders where ...

471

Magnetic and thermal properties of cubic single-crystal PrCu_4Ag  

International Nuclear Information System (INIS)

We succeeded in synthesizing a new cubic intermetallic compound PrCu_4Ag in a fcc structure. Measurements of X-ray diffraction, magnetic susceptibility, magnetization, specific heat, electrical resistivity, thermal expansion, and elastic constants have been performed on single crystals of PrCu_4Ag. A maximum value of #chi#(T) with a corresponding peak in C(T) suggests that an antiferromagnetic phase transition occurs at T_N=2.4 K, where a sudden decrease in #rho#_4_f(T) and a sharp peak in the thermal expansion coefficient #alpha#(T) were observed. Characteristic Curie-type softening was observed in the temperature dependence of the transverse mode for (C_1_1 - C_1_2)/2 and C_4_4 from 70 K down to T_N, which implies that the crystalline electric field (CEF) ground state is the magnetic triplet #GAMMA#_5. The anisotropic properties in M(T,H) and C(T,H) are studied when the external ...

2010-11-01

472

Electromagnetic structure of decuplet baryons towards the chiral regime  

Science.gov (United States)

The electromagnetic properties of the baryon decuplet are calculated in quenched QCD on a 20{sup 3}x40 lattice with a lattice spacing of 0.128 fm using the fat-link irrelevant clover fermion action with quark masses providing a pion mass as low as 300 MeV. Magnetic moments and charge radii are extracted from the electric and magnetic form factors for each individual quark sector. From these, the corresponding baryon properties are constructed. We present results for the higher-order moments of the spin-3/2 baryons, including the electric-quadrupole moment E2 and the magnetic-octupole moment M3. The world's first determination of a nonzero M3 form factor for the {delta} baryon is presented. With these results we provide a conclusive analysis which shows that decuplet baryons are deformed. We compare the decuplet-baryon results from a similar lattice calculation of the octet baryons. We establish that the environment ...

2009-09-01

473

Electrochemical synthesis of nanostructured porous materials using liquid crystal and colloidal templates and their magnetic and optical properties  

CERN Document Server

material, and that these magnetic properties vary systematically with the diameter of the spherical pores within the films. A new oscillation effect has been observed for the coercivity of macroporous Ni sub 8 sub 0 Fe sub 2 sub 0 film with different pore layer thickness. sphere templates, the resulting films show well-formed, regular, two- and three-dimensional macroporous networks consisting of spherical pores arranged in a highly ordered face centred cubic (fee) structure. The spherical voids are interconnected by a series of smaller windows that form an open porous structure embedded in the material framework. The diameter of the spherical pores can be precisely changed over the range from 200 to 1000 nm by changing the diameter of the latex spheres used to form the templates. The resulting macroporous material structures are robust, self-supported, dense, polycrystalline, uniform and free from ...

2002-01-01

474

Crystal structure and magnetic properties of Sm{sub 3}ReO{sub 7}  

Energy Technology Data Exchange (ETDEWEB)

Crystals of a new ternary samarium rhenium oxide, Sm{sub 3}ReO{sub 7} were obtained by subsolidus reaction of samariumsesquioxide and rheniumdioxide (ratio 1.5:1) in sealed Pt-10Rh-tubes at 1673 K. The structure was determined by single-crystal X-ray diffraction. Sm{sub 3}ReO{sub 7} crystallizes in the orthorohombic system with unit cell dimensions a = 10.736(5), b = 7.392(3), and c = 7.519(3) in space group Cmcm (No. 63) with Z = 4. The structure consists of ReO{sub 6} octahedra, distorted SmO{sub 6} octahedra, and SmO{sub 8} prisms that are interconnected to each other to form a three-dimensional network. Rhenium has the formal oxidation state of +5 but no metal-metal bond is observed in this compound. The observed magnetization in the temperature range 4 K < T < 52 K is explained by a Curie-Weiss law modified by a temperature independent Van Vleck paramagnetism of samarium (3+).

1996-08-01

475

Leading research on supermetal. Part 1. Large-scale materials (iron system); Super metal no sendo kenkyu. 1. Ogata sozai (tetsukei)  

Energy Technology Data Exchange (ETDEWEB)

Supermetal with critical characteristics is under advanced investigation for further improvement of metal materials. Although iron is most frequently used as structural material among various metals, it should be used more carefully and effectively because of resource limitation and global environmental problem. It is essential to draw various excellent properties much more from iron and to improve recyclability. In particular, the best way to meet these requirements is achievement of more fine structure and higher purity. Since the lowest crystalline grain size is now limited to nearly 10{mu}m, metallic structure composed of grains below 1{mu}m is expected by mesoscopic control. Various methods have been studied to achieve ultra-fine crystalline structure, and study of precise heat treatment control and ultra-strength metallurgy is required. Heat treatment in magnetic field and ...

1996-03-01

476

Ternary stannides RE_3Ru_4Sn_1_3 (RE = La, Ce, Pr, Nd). Structure, magnetic properties, and "1"1"9Sn Moessbauer spectroscopy  

International Nuclear Information System (INIS)

The ternary stannides RE_3Ru_4Sn_1_3 (RE = La, Ce, Pr, Nd) were obtained by arc-melting of the elements. The polycrystalline samples were characterized by powder X-ray diffraction. The structures of three compounds were refined from single-crystal diffractometer data: Yb_3Rh_4Sn_1_3 type, Pm anti 3n, a = 977.74(3) pm, wR2 = 0.0379, 280 F"2 values for La_3Ru_4Sn_1_3, a = 971.34(9) pm, wR2 = 0.0333, 274 F"2 values for Ce_3Ru_4Sn_1_3, a = 970.68(8) pm, wR2 = 0.0262, 272 F"2 values for Nd_3Ru_4Sn_1_3 with 13 variables per refinement. The structures consist of three-dimensional networks of condensed RuSn_6_/_2 trigonal prisms with the RE (CN 16) and Sn2 (CN 12) atoms in two different types of cavities of the networks. The two crystallographically independent tin sites have been resolved by "1"1"9Sn Moessbauer spectroscopy. Temperature-dependent magnetic susceptibility measurements of Ce_3Ru_4Sn_1_3 gave a reduced ...

2011-07-01

477

Ceramic Materials and Devices  

Science.gov (United States)

Course website from Cambridge on ceramic materials. This site contains eight lectures in PDF format (Adobe Reader required), two question sheets, five practicals (including answers), digital movies and further useful links. "There is a strong relationship between the structure of a material and its physical properties. The properties of a material whether mechanical, electrical, optical or magnetic, determine how it can be used in practical applications. In this course, the focus is on the structure / property relationship for ionic materials with electrical properties utilised in various transducer devices. The materials considered include perovskites, which have special polarisation properties exploited in ferroelectric, pyroelectric and piezoelectric devices. Other oxides, such as zirconia, have structures permitting rapid diffusion of ions, making them suitable for use in sensors, fuel cells and ...

2007-02-01

478

Synthesis of magnetic particles via a cationic-anionic surfactant vesicle method  

Energy Technology Data Exchange (ETDEWEB)

In this work, a mixed cationic--anionic [i.e. cetyltrimethylammonium bromide-sodium octyl sulphate] surfactant system was used to synthesize the magnetite particles. The loading content of iron ions (Fe{sup 3+} and Fe{sup 2+}) into the surfactant system was varied to study its effect on the formation of magnetite, magnetic and morphological properties of the magnetite particles encapsulated by the surfactant vesicles. It has been verified that the vesicle-encapsulated magnetite particles with sizes from 100 to 200 nm were formed, which were almost independent of the loading content of iron ions. However, the morphological structure of the magnetite particles was dependent on the loading content of iron ions and there existed an optimal loading content for a full packing of the surfactant vesicles with the magnetite particles.

2006-10-15

479

Synthesis of magnetic particles via a cationic-anionic surfactant vesicle method  

International Nuclear Information System (INIS)

In this work, a mixed cationic--anionic [i.e. cetyltrimethylammonium bromide-sodium octyl sulphate] surfactant system was used to synthesize the magnetite particles. The loading content of iron ions (Fe"3"+ and Fe"2"+) into the surfactant system was varied to study its effect on the formation of magnetite, magnetic and morphological properties of the magnetite particles encapsulated by the surfactant vesicles. It has been verified that the vesicle-encapsulated magnetite particles with sizes from 100 to 200 nm were formed, which were almost independent of the loading content of iron ions. However, the morphological structure of the magnetite particles was dependent on the loading content of iron ions and there existed an optimal loading content for a full packing of the surfactant vesicles with the magnetite particles.

2006-10-01

480

Magnetic susceptibility and electrical properties of Ln/sub 2/3+x/TiO/sub 3+y/ (Ln = Ce, Nd) at 77-450/sup 0/K  

Energy Technology Data Exchange (ETDEWEB)

The magnetic susceptibility and electrical resistivity in cerium and neodymium titanate bronzes in Ln/sub 2/3+x/TiO/sub 3+y/ of the perovskite structure were investigated in the temperature range 77-450/sup 0/K. The deviation of the 1/x = f(T) dependence from the Curie-Weiss law, found for a majority of the compositions, was interpreted from the crystal-field effect based on the state of the Ce/sup 3 +/ and Nd/sup 3 +/ cations. For a number of the phases, a transition from metallic conductivity at high temperatures to semiconducting conductivity was detected at temperatures below 200-250/sup 0/K, which agrees well with the conclusion about the temperature dependence of x, related to the subsystem of Ti/sup 3 +/ cations.

1987-01-01

481

Magnetic properties of some Au_3R compounds  

International Nuclear Information System (INIS)

The magnetization of a series of intermetallic compounds Au_3R, where R is Gd through Yb, was investigated at 2.5 to 300"0K in applied fields up to 26 kOe. All the compounds studied exhibited the orthorhombic TiCu_3--Do/sub a/ type structure. For high temperatures, the temperature dependence of the inverse susceptibility followed a Curie--Weiss law, yielding effective paramagnetic moments in good agreement with the values calculated for free tripositive rare earth ions. At low temperatures, deviations from Curie--Weiss behavior were observed in all cases. These deviations are ascribed to the influence of crystal-field and exchange interactions. (auth).

1974-12-03

482

Magnetic and spectral properties of Oxovanadium(IV) complexes with tridentate dibasic ONO donor Schiff bases derived from isopropanolamide and substituted salicylaldehydes  

International Nuclear Information System (INIS)

Oxovanadium(IV) complexes with tridentate dibasic ONO donor schiff bases derived from salicylaldehyde, 5-chlorosalicylaldehyde, 3,5-dichlorosalicylaldehyde, 5-bromosalicylaldehyde, 3-methoxysalicylaldehyde, 2-hydroxynaphthaldehyde and 2-amino-1-propanol have been prepared and characterised by elemental analysis, infrared, electronic and ESR spectra and magnetic susceptibility measurements from 83 to 297 deg K. On the basis of these studies, presence of triplet state (S=1) and a dimeric structure with singlet ground state (S=0) have been suggested. The V=0 stretching frequencies of the complexes occur around 980 cm"-"1. (M.G.B.).

1977-01-01

483

Giant magnetoimpedance effect and voltage response in meander shape Co-based ribbon  

British Library Electronic Table of Contents (United Kingdom)

Field-annealed Co-based amorphous ribbon (Metglas? 2705M) with a meander structure is fabricated by MEMS technology and the giant magnetoimpedance (GMI) effects are studied at different magnetic fields and frequencies. The maximum longitudinal GMI ratio of the ribbon is 193.7% and the magnetic field sensitivity is 17.4%/Oe. The maximum GMI ratio of the meander ribbon is much larger than the single strip ribbon mainly due to the larger change ratio of inductance L. The sensitivity of an output U reach up to 10 V/A and U thermal fluctuation is less than 15 mV in the temperature range of ?20 to 40?C. This meander shape ribbon can be considered as a good candidate for the GMI-based sensor fabrication.

2010-01-01

484

Effect of chemical composition on the structure and mechanical properties of Mn-Al-C alloys in the magnetic region  

Energy Technology Data Exchange (ETDEWEB)

The thermal stability and deformability of Mn-Al-C alloys containing 0.6 pct C are investigated experimentally as a function of excess phase content. It is shown that an increase in Mn content from 68.9 to 73.5 pct leads to increased stability of the high-temperature epsilon phase. The enrichment of the system Mn-Al-Cu in Mn and Al above the optimum composition leads to the formation of nonmagnetic excess phases, eta and beta, which reduce the magnetization of the alloy. In addition, a decrease in thermal stability is observed in the alloy with 73.5 pct Mn due to the decomposition of the ferromagnetic phase. 7 references.

1988-01-01

485

Magnetic properties and magnetic ordering in the rare earth molybdenum(IV) pyrochlores: R_2Mo_2O_7  

International Nuclear Information System (INIS)

The series of cubic pyrochlore structure compounds, R_2Mo_2O_7 (R = Nd-Yb, Y; R not= Eu), were prepared as single phase materials by solid state reaction between R_2O_3 and MoO_2 at 1400 "0C in a CO/CO_2 = 1 buffer gas atmosphere. Lattice constants obtained from X-ray powder data compare well with results from previous studies. Magnetic susceptibility and magnetization data were obtained for all samples between 300 K and 4.2 K (700 K for R = Gd) and a range of applied fields. For R = Nd, Sm, and Gd magnetic ordering is observed at 97 K, 93 K and 83 K respectively which is assigned to ferromagnetism on the Mo(IV) sublattice. The Mo(IV) moment in the ordered state is about 1 #mu#/sub B/. At low temperatures, the Gd(III) and Mo(IV) moments are apparently coupled feromagnetically in Gd_2Mo_2O_7 yet the high temperature susceptibility data seem to indicate a ferrimagnetic (antiparallel) Gd(III)-Mo(IV) ...

1986-01-01

486

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After surgical treatment, the ...

487

Non-white noise in fMRI: does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2005-01-01

488

Non-white noise in fMRI: Does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2006-01-01

489

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D ...

2008-04-15

490

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. Contrast MRI study is ...

491

Light liquid hydrocarbons from the catalytic pyrolysis of sewage sludge lipid  

Energy Technology Data Exchange (ETDEWEB)

The lipid obtained by the toluene extraction of a dried raw Atlanta sewage sludge by the Soxhlet method, was pyrolyzed over activated alumina at atmospheric pressure. A range of weight hourly space velocities (WHSV) from 0.22-1.60/h and a range of temperatures from 400-480[degree]C were selected. A 70 wt % yield of light liquid hydrocarbons was obtained at a WHSV of 0.46/h and 450[degree]C. The sulfur and nitrogen contents of the pyrolysis products were much lower than products from direct liquefaction of sludge. Infrared spectra and [sup 13]C nuclear magnetic resonance confirmed the absence of carbonyl groups in the products. Gas chromatography showed a uniform hydrocarbon chain length distribution across the C[sub 7] to C[sub 17] mass range. The gas product consisted mainly of carbon dioxide and hydrocarbons. Lauric acid was used as a model to study the decarboxylation. The effects of catalyst loading and catalyst moisture content were ...

1993-01-01

492

In vivo phosphorylation of histones H1 and H5 in calf thymus and chicken erythrocytes as studied by /sup 31/P nuclear magnetic resonance spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The /sup 31/P NMR method was first applied to characterize in vivo phosphorylation of H1 and H5 in calf thymus and chicken erythrocytes as well as in vitro phosphorylation of H1 and H5 by cAMP-dependent protein kinase. The amino acid residues phosphorylated in vivo in the histones were exclusively serine residues, and the mole fraction of phosphoserine was estimated to be 0.34 and 0.27 per molecule of calf thymus H1 and chicken erythrocyte H5, respectively. Interestingly, chicken erythrocyte H1 was not phosphorylated in vivo. Three H1 subtypes from calf thymus H1 varied in the /sup 31/P NMR spectra, and the bisected fragments of calf thymus H1 and chicken erythrocyte H5 exhibited characteristic spectral patterns, indicating that there are considerable diversities of the degree of phosphorylation and phosphorylation sites in very-lysine-rich histones. Furthermore, it was found that the microenvironment of phosphoserine residues phosphorylated in vivo in calf thymus H1 and chicken ...

1987-08-01

493

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium ...

1998-06-01

494

Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis.  

DEFF Research Database (Denmark)

The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly to both the results of the contrast sensitivity test ...

2002-01-01

495

Effect of external pH on the cytoplasmic and vacuolar pHs in Mung bean root-tip cells  

International Nuclear Information System (INIS)

The effect of the external pH on the intracellular pH in mung bean (Vigna mungo (L.) Hepper) root-tip cells was investigated with the "3"1P nuclear magnetic resonance (NMR) method. The "3"1P NMR spectra showed three peaks caused by cytoplasmic G-6-P, cytoplasmic Psub(i) and vacuolar Psub(i). The cytoplasmic and vacuolar pHs could be determined by comparing the Psub(i) chemical shifts with the titration curve. When the external pH was changed over a range from pH 3 to 10, the cytoplasmic pH showed smaller changes than the vacuolar pH, suggesting that the former is regulated more strictly than the latter. The H"+-ATPase inhibitor, DCCD, caused the breakdown of the mechanism that regulates the intracellular pH. H"+-ATPase appears to have an important part in the regulation of the intracellular pH. (author).

496

Early effects of boron neutron capture therapy on rat glioma models  

International Nuclear Information System (INIS)

Early effects of boron neutron capture therapy (BNCT) on malignant glioma are characterized by reduction of the enhancement area and regression of the peritumoral edema radiologically. The aim of this study was to investigate the early histological changes of tumors and inflammatory cells after BNCT in the rat brain. Rats were treated with BNCT using boronophenylalanine (BPA) 7 days after implantation of C6 glioma cells. The tumors were assessed with magnetic resonance imaging and histopathological examination at 4 days after BNCT. The mean tumor volumes were 39#+-#2 mm"3 in the BNCT group and 134#+-#18 mm"3 in the control group. In the BNCT group, tumor cells showed a less pleomorphic appearance with atypical nuclei and mitotic figures. The Ki-67 labeling index was 6.5%#+-#4.7% in the BNCT and 35%#+-#3.8% in the control group. The reactions of the inflammatory cells were examined with ED-1 as macrophage marker and OX42 as microglia marker. ...

497

Diagnostic difficulties in extraosseous Ewing's sarcoma: A proposal for diagnostic criteria  

International Nuclear Information System (INIS)

Five cases diagnosed as extraosseous Ewing's sarcoma (EES) during a 15 year period, and the relevant literature, were reviewed. The diagnosis in these cases was difficult to confirm, mainly because the distinction between the osseous form of Ewing's sarcoma (OES) and either periosteal reactions or direct tumour invasion into adjacent bone by EES was often unclear. The literature suggests that other authors have also encountered difficulties. The authors believe that many cases reported as EES are likely to have been OES. This distinction has some importance, as the two conditions are usually treated in differing ways. The following criteria are proposed for the diagnosis of primary EES: (i) no evidence of bony involvement on magnetic resonance imaging; (ii) no evidence of increased uptake in bone or periosteum adjacent to the tumour on static isotope bone scan images; (iii) a small round cell tumour with no differentiating features on light ...

498

Application of spectroscopic techniques for the study of paper documents: A survey  

International Nuclear Information System (INIS)

For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear ...

2009-06-01

499

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...

1998-02-01

500

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research ...

2009-03-15