WorldWideScience
1

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

2

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

3

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

5

Calorimetric and spectroscopic studies of the polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines.  

UK PubMed Central (United Kingdom)

The polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines was investigated by differential scanning calorimetry, 31P-nuclear magnetic resonance, and Fourier...Full Text Available

1993-04-01

6

Nuclear magnetic resonance and the question of 5f electron localization in the actinides  

International Nuclear Information System (INIS)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5f electrons. (author).

7

Nuclear magnetic resonance and the question of 5F electron localization in the actinides  

Science.gov (United States)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5Line integral electrons.

1976-01-01

17

Nuclear magnetic resonance study of La_3X compounds and related phases  

International Nuclear Information System (INIS)

Normal state nuclear magnetic resonance studies of the La_3In, La_3Tl compounds have been made in order to investigate the origin of the large temperature-dependent magnetic susceptibility. It is possible to analyse the different contributions to the susceptibility using Knight-shift and relaxation time T_1 measurements of In"1"1"5 and Tl"2"0"5 nuclei. The exchange enhancement of the spin-susceptibility chisub(pd) is of the same order as that found in A-15 compounds and the strong temperature-dependence of chi(T) is attributed to the presence of a peak in the electronic density of states near the Fermi level. The variation of the Knight-shift in the ternary alloys La_3Xsub(1-y)Xsub(y)sup(') is analogous to that observed in the corresponding La_3X phases, on the other hand the Knight-shift in the carbides La_3XC is temperature independent. (author).

18

Electron phonon properties of A-15 compounds and Chevrel phases  

International Nuclear Information System (INIS)

A review of the information on the electron and phonon spectra in the A-15 compounds and Chevrel phase superconductors obtained from nuclear magnetic resonance, heat capacity, and Moessbauer effect experiments is presented. Relationships of the Fermi energy electrons and the soft phonons to the strength of the electron-phonon interaction are discussed.

19

Electron and phonon properties of A-15 compounds and Chevrel phases  

International Nuclear Information System (INIS)

A review of the information on the electron and phonon spectra in the A-15 compounds and Chevrel phase superconductors obtained from nuclear magnetic resonance, heat capacity, and Moessbauer effect experiments is presented. Relationships of the Fermi energy electrons and the soft phonons to the strength of the electron-phonon interaction are discussed.

20

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

31

Magnetic resonance imaging of the hip with a pelvic phased-array surface coil: a technical note  

Energy Technology Data Exchange (ETDEWEB)

Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of ...

1998-02-01

32

Spontaneous and stimulated Raman studies of vibrational dephasing in condensed phases  

Energy Technology Data Exchange (ETDEWEB)

Vibrational dephasing in condensed phases is studied from both a theoretical and experimental standpoint. A theory is presented which describes the dynamics of motional or exchange processes in weakly perturbed systems. This general formalism, which has been previously used to describe motional narrowing in magnetic resonance, is applied to vibrational spectroscopy. The model treats the case of a high frequency vibration anharmonically coupled to a low-frequency vibration. Intermolecular exchange of low frequency vibrational quanta results in a temperature dependent broadening and frequency shift of the high frequency vibration. Analysis of experimental data by this model yields both the exchange rates and the anharmonic couplings.

1980-05-01

33

Nuclear resonant spectroscopy at Bragg reflections from periodic multilayers: Basic effects and applications  

Science.gov (United States)

A systematic study of the Bragg nuclear resonant reflectivity from periodic multilayers in the energy and time domains is presented. Using the kinematical approach of the general reflectivity theory we describe the basic features of the time evolution of the reflected wave after a pulsed excitation of resonant multilayers by synchrotron radiation. Effects of the collective excitation have been examined such as the shift of quantum beat phases, the interplay between electronic and nuclear subsystem excitations depending on their relative position in a multilayer, the energy and time evolution of standing waves inside a resonant multilayer, and their influence on the reflectivity spectra. The exact expression for the reflectivity by a thin resonant layer placed inside a multilayer structure has been derived. The observed shift of the delayed reflectivity Bragg peak relative to the ...

2005-09-15

34

Current applications of magnetic resonance in coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)

1982-01-01

35

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

36

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

37

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

38

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

39

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

40

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

43

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

46

Influence of resonant US on H-NMR at application of magnetic nanoparticles  

International Nuclear Information System (INIS)

2010 [1 p.] Germany Repp, Felix El-Miladi, Nouri Hoehl, Christian Jahanbakhsh,

2010-03-21

49

Pure NQR quantum computing  

Energy Technology Data Exchange (ETDEWEB)

It is shown that pure NQR can be utilized as a platform for quantum computing without applying a high external magnetic field. By exciting each resonance transition between quadrupole energy levels with two radio-frequency fields differing in phase and direction, the double degeneracy of the spin energy spectrum in an electric field gradient is removed. As an example, in the case of I=7/2 (nuclei {sup 133}Cs or {sup 123}Sb) the energy spectrum has eight levels which can be used as three qubits. (orig.)

2002-07-01

50

Electron paramagnetic resonance of nitroxide-doped magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.

2002-11-01

51

Structure and magnetic properties of the UNi_1_0_-_xFe_xSi_2 system and "2"9Si nuclear magnetic resonance in UNi_1_0Si_2  

International Nuclear Information System (INIS)

Structure and magnetic properties of UNi_1_0_-_xFe_xSi_2 intermetallics and "2"9Si nuclear magnetic resonance (NMR) in UNi_1_0Si_2 are investigated in a wide temperature range. Solid solutions in the exactly single-phase tetragonal form, ThMn_1_2 type, exist for x<2. The Ni and Fe atoms occupy the 8(f), 8(i) and 8(j) positions statistically, whereas the U atoms occupy the 2(a) and the Si atoms the 8(j) sites. The lattice parameters roughly follow Vegard's law. The magnetic susceptibility does not exhibit Curie-Weiss behaviour and, at about 630 K, an anomaly in the temperature dependence is observed. At low temperature, other anomalies are observed at 32 K and 45 K, for x=0.5 and 1.0 respectively. These low temperature anomalies are probably connected with magnetic ordering of a ferromagnetic character, whereas that at 630 K might result from the ...

1993-09-01

52

Studying the internal structure of granular magnetic nanocomposites by ferromagnetic resonance  

British Library Electronic Table of Contents (United Kingdom)

A method for estimating the form of magnetic nanoparticles in composite film structures based on the observation of ferromagnetic resonance phenomenon is offered. Within the model of the effective medium, an explanation is given for experimentally observed concentration and temperature dependences of resonant fields for composite nanosystem (Co45Fe45Z10) f +(Al2O3)100?f .

2010-01-01

54

T{sub 1} and T{sub 2} relaxivities of succimer-coated MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

Energy Technology Data Exchange (ETDEWEB)

Superparamagnetic MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r{sub 2}/r{sub 1}, for MnFe{sub 2}O{sub 4}, Fe{sub 3}O{sub 4} and CoFe{sub 2}O{sub 4} were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T{sub 2} contrast agents for MRI.

2009-12-15

55

T1 and T2 relaxivities of succimer-coated MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

International Nuclear Information System (INIS)

Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.

2009-12-01

56

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the ...

1985-08-01

57

Towards Resonant-State THz Laser Based on Strained p-Ge ...  

Science.gov (United States)

... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...

2006-07-01

58

Tarlov Cyst and Infertility  

UK PubMed Central (United Kingdom)

Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available

2009-04-01

59

Magnetic resonance imaging in human lymphodemas  

International Nuclear Information System (INIS)

The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).

1989-09-02

62

Horizontal vibration suppression method suitable for super-high-speed elevators; Chokosoku elevator ni tekishita kago yokoshindo yokusei hoshiki  

Energy Technology Data Exchange (ETDEWEB)

Horizontal vibrations of elevator cars mainly occur because a car swings as roller guides installed at corners of a car frame move on a winding guide rail at high speeds. Rider comfort in high speed elevators is worsened by these vibrations. Conventional active dampers suppressing horizontal vibrations using ac servo motors make cars heavier so driving power becomes larger, and they are not easily applied to existing elevators. An active damping control method suited to super-high-speed elevators is which can solve these problems. The method suppresses vibrations by generating only enough magnetic force needed to suppress them only when vibrations of the car franc are produced. The vibrations are detected using acceleration detectors and magnets installed on left and right sides of the car frame. A computer simulator was made to analyze phenomena of car vibrations and to verify effects of the proposed magnetic damping ...

1998-03-01

63

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

64

Study of the cyclotron feature in MXB 0656-072  

CERN Document Server

We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.

2006-01-01

65

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

66

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends ...

1995-12-31

67

Cauchy problem for the Mathieu equation away from parametric resonance  

British Library Electronic Table of Contents (United Kingdom)

Four solutions of the Cauchy problem for Mathieu?s equation away from parametric resonance domains are analytically constructed using an asymptotic averaging method in the fourth approximation. Three solutions occur near fractional parameter values at which slow combination phases exist. The fourth solution occurs in the absence of slow phases away from parametric resonance domains and the fractional parameter values.

2011-01-01

68

Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?  

UK PubMed Central (United Kingdom)

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available

2009-03-01

69

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

70

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

71

Magnetic resonance appearance of fibromatosis  

International Nuclear Information System (INIS)

We reviewed retrospectively the magnetic resonance (MR) images of 14 soft-tissue lesions of fibromatosis (desmoid tumors) encountered in 11 patients. The lesions were typically inhomogeneous in texture and round to oval in configuration. Margins were well-defined in 78% of the lesions at presentation and were infiltrating in all recurrences. (orig./DG).

72

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

73

Fatty acid distribution in systems modeling the normal and diabetic human circulation. A 13C nuclear magnetic resonance study.  

UK PubMed Central (United Kingdom)

A nonperturbing 13C nuclear magnetic resonance (NMR) method was used to monitor the equilibrium distribution of carboxyl 13C-enriched fatty acids (FA) between distinct binding sites on human serum albumin,...Full Text Available

1991-04-01

74

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

75

Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness  

UK PubMed Central (United Kingdom)

BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available

76

Moderately heavy, heavy-fermion compound YbPd_2Si_2 at low temperatures  

International Nuclear Information System (INIS)

The available experimental data on the specific heat, magnetic susceptibility, magnetization, valence, NMR Knight shift and relaxation rate, and the quadrupolar moment of YbPd_2Si_2 are examined within the framework of the single-ion Anderson model. Such an analysis has previously given excellent agreement between theory and experiment for numerous other light heavy-fermion compounds, where crystalline fields do not play a dominant role. For YbPd_2Si_2, substantial crystalline-field splittings make difficult a quantitative comparison with existing exact solutions of the Anderson model. Inconsistencies with the interpretation that a nearly degenerate ground quadruplet determines the low-temperature thermodynamics are pointed out. It is concluded that at least three of the four Kramers doublets participate in the low-T properties. These three doublets should have a splitting of the order of the Kondo temperature, i.e., about 100 K. A simple ...

77

Moderately heavy, heavy-fermion compound YbPd sub 2 Si sub 2 at low temperatures  

Energy Technology Data Exchange (ETDEWEB)

The available experimental data on the specific heat, magnetic susceptibility, magnetization, valence, NMR Knight shift and relaxation rate, and the quadrupolar moment of YbPd{sub 2}Si{sub 2} are examined within the framework of the single-ion Anderson model. Such an analysis has previously given excellent agreement between theory and experiment for numerous other light heavy-fermion compounds, where crystalline fields do not play a dominant role. For YbPd{sub 2}Si{sub 2}, substantial crystalline-field splittings make difficult a quantitative comparison with existing exact solutions of the Anderson model. Inconsistencies with the interpretation that a nearly degenerate ground quadruplet determines the low-temperature thermodynamics are pointed out. It is concluded that at least three of the four Kramers doublets participate in the low-{ital T} properties. These three doublets should have a splitting of the order of the Kondo temperature, i.e., ...

1992-07-01

78

Assembly of Linear Nano-Chains from Iron Oxide Nanospheres with Asymmetric Surface Chemistry  

Science.gov (United States)

Besides the multifunctionality, another equally important aspect of nanoparticles is their engineerability to control the geometrical and chemical properties during fabrication. In this work, we exploited this aspect to define asymmetric surface chemistry of an iron oxide nanosphere by controlling the topology of ligand expression on its surface resulting in a particle with two faces, one displaying only amines and the other only thiols. Specifically, amine-functionalized iron oxide nanospheres were attached on a solid support via a crosslinker containing a disulfide bridge. Liberation of the nanosphere using thiolytic cleavage created thiols on the portion of the particle's surface that interacted with the solid support. Employing a solid-phase strategy and a step-by-step addition of particles, the two unique faces on the same nanosphere served as fittings to assemble them into linear nano-chains. Assembly of chains with various lengths and aspect ratios was ...

2011-01-06

79

Effect of magnet sorting using a simple resonance cancellation method on the RMS orbit distortion at the APS injector synchrotron  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.

1993-07-01

80

Photon shell game in three-resonator circuit quantum electrodynamics  

CERN Document Server

The generation and control of quantum states of light constitute fundamental tasks in cavity quantum electrodynamics (QED). The superconducting realization of cavity QED, circuit QED, enables on-chip microwave photonics, where superconducting qubits control and measure individual photon states. A long-standing issue in cavity QED is the coherent transfer of photons between two or more resonators. Here, we use circuit QED to implement a three-resonator architecture on a single chip, where the resonators are interconnected by two superconducting phase qubits. We use this circuit to shuffle one- and two-photon Fock states between the three resonators, and demonstrate qubit-mediated vacuum Rabi swaps between two resonators. This illustrates the potential for using multi-resonator circuits as photon quantum registries and for creating ...

2010-01-01

81

Intrinsic magnetism in Fe doped SnO2 nanoparticles  

International Nuclear Information System (INIS)

Iron doped semiconducting nanoparticles Sn1-xFexO2 with x=0, 0.001, 0.002, 0.003, 0.004, 0.01 and 0.03 were prepared by a sol-gel method. The X-ray diffraction, Transmission Electron Microscopy measurements confirm the rutile structure with no impurity phase. The three characteristic lines of electron spin resonance (ESR) are observed in the doped samples for all compositions, which is a clear evidence for rhombic Fe3+ in rutile phase. The line width of ESR increases with increase in Fe concentration due to induced disorder. The spin-pumping effect is observed at temperatures below 250 K for the samples with x=0.01 and 0.03. However, based on the Curie-Weiss susceptibility, iron is in paramagnetic state and is subject to weak antiferromagnetic interaction. Blue shift in the optical band gap is observed with increase in the Fe content. -- Graphical abstract: The ESR spectra reveal that the nature of Fe in Sn1-xFexO2 samples ...

2011-01-01

82

Kondo effect in the systems of magnetic trimers on a metal surface  

International Nuclear Information System (INIS)

Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)

2010-11-01

83

Delta connected resonant snubber circuit  

Energy Technology Data Exchange (ETDEWEB)

A delta connected, resonant snubber-based, soft switching, inverter circuit achieves lossless switching during dc-to-ac power conversion and power conditioning with minimum component count and size. Current is supplied to the resonant snubber branches solely by the dc supply voltage through the main inverter switches and the auxiliary switches. Component count and size are reduced by use of a single semiconductor switch in the resonant snubber branches. Component count is also reduced by maximizing the use of stray capacitances of the main switches as parallel resonant capacitors. Resonance charging and discharging of the parallel capacitances allows lossless, zero voltage switching. In one embodiment, circuit component size and count are minimized while achieving lossless, zero voltage switching within a three-phase inverter.

1998-01-01

84

Nuclear magnetic resonance on oriented XVTa and XXTa  

Energy Technology Data Exchange (ETDEWEB)

XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.

1984-08-01

85

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

86

The Influence of Moderate Hypercapnia on Neural Activity in the Anesthetized Nonhuman Primate  

UK PubMed Central (United Kingdom)

Hypercapnia is often used as vasodilatory challenge in clinical applications and basic research. In functional magnetic resonance imaging (fMRI), elevated CO2 is applied to derive stimulus-induced...Full Text Available

2008-11-01

87

Teaching electron diffraction and imaging of macromolecules.  

UK PubMed Central (United Kingdom)

Electron microscopic analysis can be used to determine the three-dimensional structures of macromolecules at resolutions ranging between 3 and 30 A. It differs from nuclear magnetic resonance spectroscopy...Full Text Available

1993-05-01

88

Synthesis and characterization of PVP-coated large core iron oxide nanoparticles as an MRI contrast agent  

UK PubMed Central (United Kingdom)

The purpose of this study was to synthesize biocompatible polyvinylpyrrolidone (PVP)-coated iron oxide (PVP-IO) nanoparticles and to evaluate their efficacy as a magnetic resonance imaging (MRI)...Full Text Available

2008-04-01

89

Specialization along the Left Superior Temporal Sulcus for Auditory Categorization  

UK PubMed Central (United Kingdom)

The affinity and temporal course of functional fields in middle and posterior superior temporal cortex for the categorization of complex sounds was examined using functional magnetic resonance imaging...Full Text Available

2010-12-01

90

Solid-state 13C NMR spectroscopy of a 13C carbonyl-labeled polypeptide  

UK PubMed Central (United Kingdom)

High resolution structural elucidation of macromolecular structure by solid-state nuclear magnetic resonance requires the preparation of uniformly aligned samples that are isotopically labeled. In...Full Text Available

1992-06-01

91

Retinal channelrhodopsin-2-mediated activity in vivo evaluated with manganese-enhanced magnetic resonance imaging  

UK PubMed Central (United Kingdom)

PurposeEctopic expression of light-sensitive proteins, such as channelrhodopsin-2, represent a novel approach for restoring light-detection capabilities to degenerated retina. A...Full Text Available

92

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

93

Nylon biodegradation by lignin-degrading fungi.  

UK PubMed Central (United Kingdom)

The biodegradation of nylon by lignin-degrading fungi was investigated. The fungus IZU-154 significantly degraded nylon-66 membrane under ligninolytic conditions. Nuclear magnetic resonance analysis...Full Text Available

1997-01-01

94

New approach to study fast and slow motions in lipid bilayers: application to dimyristoylphosphatidylcholine-cholesterol interactions.  

UK PubMed Central (United Kingdom)

Natural abundance 13C solid-state nuclear magnetic resonance spectroscopy was used to investigate the effect of the incorporation of cholesterol on the dynamics of dimyristoylphosphatidylcholine (DMPC)...Full Text Available

1995-05-01

95

Neurosarcoidosis--demonstration of meningeal disease by gadolinium enhanced magnetic resonance imaging.  

UK PubMed Central (United Kingdom)

Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available

1991-06-01

96

Monitoring of Tumor Promotion and Progression in a Mouse Model of Inflammation-Induced Colon Cancer with Magnetic Resonance Colonography1  

UK PubMed Central (United Kingdom)

Early detection of precancerous tissue has significantly improved survival of most cancers including colorectal cancer (CRC). Animal models designed to study the early stages of cancer are valuable...Full Text Available

2009-03-01

97

Measuring the thickness of the human cerebral cortex from magnetic resonance images  

UK PubMed Central (United Kingdom)

Accurate and automated methods for measuring the thickness of human cerebral cortex could provide powerful tools for diagnosing and studying a variety of neurodegenerative and psychiatric disorders....Full Text Available

2000-09-26

98

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

99

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models  

UK PubMed Central (United Kingdom)

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation....Full Text Available

2009-05-01

100

MRI Findings of Pericardial Fat Necrosis: Case Report  

UK PubMed Central (United Kingdom)

Pericardial fat necrosis is an infrequent cause of acute chest pain and this can mimic acute myocardial infarction and acute pericarditis. We describe here a patient with the magnetic resonance imaging...Full Text Available

2011-05-01

102

Interictal Functional Connectivity of Human Epileptic Networks Assessed by Intracerebral EEG and BOLD Signal Fluctuations  

UK PubMed Central (United Kingdom)

In this study, we aimed to demonstrate whether spontaneous fluctuations in the blood oxygen level dependent (BOLD) signal derived from resting state functional magnetic resonance imaging (fMRI) reflect...Full Text Available

103

In vivo study of chloroplast volume regulation.  

UK PubMed Central (United Kingdom)

This paper describes a new technique that can be used to study chloroplast volume regulation in vivo. Nuclear magnetic resonance spectroscopy was used to measure relative amounts of chloroplast water...Full Text Available

1992-05-01

104

Energy metabolism of the untrained muscle of elite runners as observed by 31P magnetic resonance spectroscopy: evidence suggesting a genetic endowment for endurance exercise.  

UK PubMed Central (United Kingdom)

The purpose of this study was to investigate whether genetically determined properties of muscle metabolism contribute to the exceptional physical endurance of world-class distance runners. ATP, phosphocreatine,...Full Text Available

1988-12-01

105

Effects of norepinephrine infusion on myocardial high-energy phosphate content and turnover in the living rat.  

UK PubMed Central (United Kingdom)

Using 31P-nuclear magnetic resonance, we studied the relationship between myocardial high-energy phosphate content and flux values for the creatine kinase reaction in the living rat under inotropic...Full Text Available

1987-06-01

106

EXPONENTIAL TENSORS: A FRAMEWORK FOR EFFICIENT HIGHER-ORDER DT-MRI COMPUTATIONS  

UK PubMed Central (United Kingdom)

In Diffusion Tensor Magnetic Resonance Image (DT-MRI) processing a 2nd order tensor has been commonly used to approximate the diffusivity function at each lattice...Full Text Available

2007-05-15

107

Current Role and Future Perspectives of Magnetic Resonance Spectroscopy in Radiation Oncology for Prostate Cancer  

UK PubMed Central (United Kingdom)

Prostatic neoplasms are not uniformly distributed within the prostate volume. With recent developments in three-dimensional intensity-modulated and imageguided radiation therapy, it is possible to treat...Full Text Available

2007-06-01

108

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

109

Cardiovascular magnetic resonance guided electrophysiology studies  

UK PubMed Central (United Kingdom)

Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available

110

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

111

Polarized proton acceleration at the Brookhaven AGS  

Energy Technology Data Exchange (ETDEWEB)

At the conclusion of polarized proton commissioning in February 1986, protons with an average polarization of 45%, momentum of 21.7 GeV/c, and intensity of 2 x 10/sup 10/ protons per pulse, were extracted to an external polarimeter at the Brookhaven AGS. In order to maintain this polarization, five intrinsic and nearly forty imperfection depolarizing resonances had to be corrected. An apparent interaction between imperfection and intrinsic resonances occurring at very nearly the same energy was observed and the correction of imperfection resonances using ''beat'' magnetic harmonics discovered in the previous AGS commissioning run was further confirmed.

1986-01-01

112

Models of cardiac electromechanics based on individual hearts imaging data  

British Library Electronic Table of Contents (United Kingdom)

Current multi-scale computational models of ventricular electromechanics describe the full process of cardiac contraction on both the micro- and macro- scales including: the depolarization of cardiac cells, the release of calcium from intracellular stores, tension generation by cardiac myofilaments, and mechanical contraction of the whole heart. Such models are used to reveal basic mechanisms of cardiac contraction as well as the mechanisms of cardiac dysfunction in disease conditions. In this paper, we present a methodology to construct finite element electromechanical models of ventricular contraction with anatomically accurate ventricular geometry based on magnetic resonance and diffusion tensor magnetic resonance imaging of the heart. The electromechanical model couples detailed repres...

2011-01-01

113

Inborn Errors of Metabolism Presenting in Childhood  

British Library Electronic Table of Contents (United Kingdom)

Abstract Neurodegenerative and neurometabolic disorders may cause significant morbidity and mortality in children. Imaging is important in early diagnosis of metabolic disorders and in determining the extent of brain injury. Especially after the development of new techniques such as diffusion-weighted magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), neuroimaging plays more important role in the diagnosis and management of these disorders. In these disorders, usually a mutation causes a clinically significant block in one or more metabolic pathways. This blockage usually results in either a deficiency of the product or in an accumulation of substrate with damage induced by either storage or toxicity. The presenting symptoms are usually nonspecific. In some of the ...

2011-01-01

114

In vivo magnetic resonance techniques and drug discovery  

International Nuclear Information System (INIS)

The long and resource intensive process of drug discovery and development is confronted with the basic challenge of providing effective and safe therapies at reasonably low costs. The better the mechanism of a disease is known, the higher the probability to find an appropriate therapy. Also, the better and earlier a disease can be diagnosed and characterized, the higher the chance to be able to interfere in this process with a chemical entity. This reasoning sets the framework for the use of imaging in drug discovery. We discuss the relevance of magnetic resonance imaging and spectroscopy to derive anatomical, functional, metabolic and target-related information in the context of pharmacological research in vivo. (author)

2006-03-01

115

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

116

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

117

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

118

Magnetic resonance studies of photosynthetic reaction centers and porphyrins  

Science.gov (United States)

During the period covered by this report research has been concerned with the study of photo-induced electron transfer reactions from porphyrins to acceptor molecules with time-resolved Electron Paramagnetic Resonance (EPR) methods. Excited-state electron transfer reactions are of importance from a fundamental point of view and in connection with applications in homogeneous and heterogeneous photosensitization, photopolymerization, and solar energy conversions. For this reason, the study of photo-induced electron transfer reactions is of considerable interest.

1989-11-01

119

MRS of normal and impaired fetal brain development  

International Nuclear Information System (INIS)

Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain ...

2006-02-01

120

Enzymatic synthesis and carbon-13 nuclear magnetic resonance conformational studies of disaccharides containing #beta#-D-galactopyranosyl and #beta#-D-[1-"1"3C]Galactopyranosyl residues  

International Nuclear Information System (INIS)

Partially purified UDPgalactosyltransferase (EC 2.4.1.22) from bovine milk has been used to synthesize millimolar amounts of compounds such as Gal#beta#(1#->#4)Glc, Gal#beta#(1#->#4)GlcNAc-#beta#-hexanolamine, and Gal#beta#(1#->#4)-GlcNAc#beta#(1#->#4)GlcNAc. The same method has been used to prepare similar compounds containing "1"3C-enriched galactopyranosyl moieties. Gal#beta#(1#->#4)GlcNAc-#beta#-hexanolamine was also synthesized in a solid-phase system in which the GlcNAc-#beta#-hexanolamine glycoside was covalently linked to agarose beads. At pH 7.0 and at 1 to 5 mM Mn"2"+"+ the yields of the galactosyl saccharides are greater than 90% by using 10% excess of UDPGal donor. The use of a 90% enriched [1-"1"3C]galactosyl residue allowed the determination of the most abundant conformer about the galactopyranosyl-glycoside linkage by analysis of the carbon-carbon coupling constants from Cl to Gal to the C3', C4', and C5' of GlcNAc or Glc. 3 figures, 1 ...

121

Early effects of boron neutron capture therapy on rat glioma models  

International Nuclear Information System (INIS)

Early effects of boron neutron capture therapy (BNCT) on malignant glioma are characterized by reduction of the enhancement area and regression of the peritumoral edema radiologically. The aim of this study was to investigate the early histological changes of tumors and inflammatory cells after BNCT in the rat brain. Rats were treated with BNCT using boronophenylalanine (BPA) 7 days after implantation of C6 glioma cells. The tumors were assessed with magnetic resonance imaging and histopathological examination at 4 days after BNCT. The mean tumor volumes were 39#+-#2 mm"3 in the BNCT group and 134#+-#18 mm"3 in the control group. In the BNCT group, tumor cells showed a less pleomorphic appearance with atypical nuclei and mitotic figures. The Ki-67 labeling index was 6.5%#+-#4.7% in the BNCT and 35%#+-#3.8% in the control group. The reactions of the inflammatory cells were examined with ED-1 as macrophage marker and OX42 as microglia marker. ...

122

#beta#-sialon via carbothermal reduction using brown coal  

International Nuclear Information System (INIS)

There has been a good deal of interest in the sialon system of ceramics in recent years due to their combination of important engineering properties #beta# including strength, hardness, low thermal expansion and good thermal shock resistance. #beta#-sialon (Si_6_-_zAl_zO_zN_8_-_z ;0Magnetic Resonance techniques in determining the nature of intermediate phases which occur. 9 refs., 1 tab., 1 ...

123

Amorphous to crystalline phase transformation in Metglas reg-sign studied by Moessbauer spectroscopy  

International Nuclear Information System (INIS)

The authors present differential scanning calorimetry (DSC) and in situ Moessbauer spectroscopy results for Metglas ribbons, to which different heat treatments were made. The Curie temperature of the amorphous phase is determined and the evolution of the magnetic field of this phase is studied as a function of temperature

1997-12-01

124

Nanocrystalline permanent magnets with enhanced properties  

International Nuclear Information System (INIS)

Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

2001-09-23

125

Resonant overvoltage phenomena caused by transmission line faults  

Energy Technology Data Exchange (ETDEWEB)

Resonant overvoltages in EHV transformers can be initiated by transmission line faults. A series of field tests were performed on the 151 mile long Kammer-Marysville 765 kV line in which a sequence of single line to ground faults were applied to one outside phase at 4 different locations. Fault location criteria and fault initiation procedures are presented. Oscillograms recorded the 3 phase response at both terminals of the line; one is transformer terminated, the other is open-ended. A frequency spectrum analysis of the waveforms is provided showing transient frequencies of sufficient magnitude and duration near the EHV transformer's resonant frequency to stimulate internal winding resonant overvoltages. Digital computer studies are presented and agree with the field tests quite favorably.

1985-09-01

126

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

127

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be ...

2003-07-01

128

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were presented as color-coded anatomically-mapped ...

129

Influence of relaxation phenomena in liquid phase on magnetic anisotropy of metallic glasses  

International Nuclear Information System (INIS)

It if first shown, that the effective field of uniaxial magnetic anisotropy of Fe-Cr-P-C and Fe-Ni-B-Si system amorphous alloys is reduced with an increase of the source melt isothermal exposure time. The behaviour noted is conditioned by microcoherence and relaxation processes in the nonequilibrium liquid phase after crystal-liquid phase transition.

1996-12-01

130

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower ...

1993-06-01

131

Crossover of the magnetic levels and adiabatic magnetization of the mesoscopic cluster V15  

British Library Electronic Table of Contents (United Kingdom)

The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...

2006-01-01

132

Magnetic phase diagrams of the TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} systems  

Energy Technology Data Exchange (ETDEWEB)

The a.c. susceptibility and high field magnetization of TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} compounds were investigated up to 140 kOe. The (T, x) magnetic phase diagrams were determined. For both systems, an increase in the Pd content causes a decrease in the Neel temperature and changes the magnetization curves. (orig.)

1995-12-01

133

Optimum arrangements of the phase conductors of overhead transmission lines for the electric field minimization  

Energy Technology Data Exchange (ETDEWEB)

The magnitude of electric and magnetic fields around a high voltage three-phase transmission line was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmission lines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmission lines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.

1997-12-31

134

Optimum arrangements of the phase conductors of overhead transmission lines for the electric field minimization  

International Nuclear Information System (INIS)

The magnitude of electric and magnetic fields around a high voltage three-phase transmission line was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmission lines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmission lines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.

1997-08-24

135

A Simple Scheme for Realizing a Multiqubit Controlled-Phase Gate Through a Resonant Interaction of Three-Level Atoms with a Single-Mode Cavity  

International Nuclear Information System (INIS)

A very simple theoretical scheme is proposed to implement two- and three-qubit controlled-phase gates firstly only using a single resonant interaction between ladder-type three-level atoms and the single-mode cavity. In the presented protocol, the quantum information is encoded on the stable ground states of the atoms (as the controlling qubits) and the zero- and one-photon Fock states of cavity-field (as the target qubit). Under the influence of the atomic spontaneous emission, the decay of the cavity-mode, and deviation of the coupling strength, the three-qubit controlled-phase gate may have a comparatively high fidelity. The experimental feasibility of controlled-phase gate and the case that is extended to realize N-qubit controlled-phase gate are also discussed. (general)

2010-03-15

136

Occurrence of magnetism in superconductors  

Science.gov (United States)

We discuss how magnetic phenomena affect superconductivity in simple metals, transition metals and alloys thereof, and dilute Rare-Earth alloys. It is shown both qualitatively and quantitatively that superconductors are sensitive probes for studying itinerant spin excitations, local spin excitations associated with nearly magnetic impurities, the effect of the atomic environment on the stability of local magnetic moments, and the nature of the spin order in Rare-Earth alloys. Also, we discuss how magnetic impurities can be used to study the electronic configuration which is responsible for superconductivity in Laves-phase crystals like A-15 compounds and ..beta..-W crystals, for example.

1970-12-14

137

Magnetic-field-induced phase transitions in Wigner molecules  

Energy Technology Data Exchange (ETDEWEB)

A theoretical analysis of formation and symmetry transformations is presented for Wigner molecules with N = 2,..., 20 electrons confined in quantum dots at high magnetic fields. Using the unrestricted Hartree-Fock method with the multicentre Gaussian basis, we have found that Wigner molecules with N {>=} 6 abruptly change their shape and symmetry with an associated jump in the first derivative of the ground-state energy, i.e. they undergo phase transitions. In particular, the phases of the Wigner molecules obtained just after emerging from the maximum-density droplet (MDD) phase possess a different symmetry from that formed at a high magnetic field. We show that the properties of the electron-electron interaction energy demonstrate very well both the breakdown of the MDD and the quasi-classical character of the Wigner molecule in the high magnetic field. ...

2003-06-25

138

Magnetic layer formation on plasma nitrided CoCrMo alloy  

British Library Electronic Table of Contents (United Kingdom)

In this study structural and magnetic character of the expanded austenite phase (gN) layer formed on a medical grade CoCrMo alloy by a low-pressure Radio-Frequency plasma nitriding process was investigated. The formation of the expanded austenite phase is facilitated at a substrate temperature near 400^oC for 1, 2, 4, 6 and 20h under a gas mixture of 60% N2-40% H2. The magnetic state of the gN layers was determined by a surface sensitive technique, magneto-optic Kerr effect (MOKE), and with a scanning probe microscope in magnetic force mode (MFM). Strong evidence for the ferromagnetic nature of the gN-(Co,Cr,Mo) phase is provided by the observation of stripe domain structures and the hysteresis loops. The ferromagnetic state for the gN phase observed here is mainly linked to large lattice ...

2011-01-01

139

Spot size and Guoy phase invariant telescope for auto-alignment of resonant cavities  

International Nuclear Information System (INIS)

We present both the theory and an experimental method to accurately set up a Guoy phase telescope, where both the output spot size and orthogonality condition are invariant to distance from the cavity beam waist. We demonstrate that Gaussian spot size measurements can be used as a diagnostic to determine the desired locations of split area photodetectors. The Guoy phase invariance is verified using the tilt-locking technique.

2004-03-07

140

Potential description of cluster channel of lithium nuclei  

International Nuclear Information System (INIS)

The new Gaussian potentials and interactions with forbidden states consistent with the phase scattering at low energies were obtained. Cross sections, resonance level spectra and some characteristics of bound states of lithium nuclei are calculated with these potentials.

141

Magnetic and chemical changes in marine sediments  

Energy Technology Data Exchange (ETDEWEB)

A considerable amount of chemical knowledge of marine sediments has been acquired in recent years but has not yet been utilized by paleomagnetists. On the other hand, geochemists are often unaware of the usefulness of numerous magnetic techniques. In this review we try to bridge this gap, and in particular, we outline many of the chemical and magnetic principles that should allow paleomagnetists to better identify and undertand chemical changes that affect the magnetic properties of marine sediments. The chemical principles include those for distinguishing the four major sources of sediments (continental, biological, authigenic/hydrogenous, volcanic/hydrothermal) from one another by determining elemental abundance distributions, as well as for investigating the stabilities of mineral phases relative to changes in pE and pH. The magnetic principles include the effects of authigenesis ...

1980-05-01

142

Microstructure modifications and modulated piezoelectric responses in PLZT/Al{sub 2}O{sub 3} composites  

Energy Technology Data Exchange (ETDEWEB)

Piezoelectric ceramics for acoustic applications have been prepared by mixing the piezoelectric phase Pb{sub 1-1.5x}La{sub x}{open_square}{sub x/2}(Ti{sub 1-y}Zr{sub y})O{sub 3} (PLZT) with variable fractions of Al{sub 2}O{sub 3}. The samples are in form of pellets and polarized at high temperature. After thermal treatment, X-ray diffraction and scanning electron microscopy have been used to determine the phase and morphological modifications. The morphotropic PLZT initial phase disproportionates into modified PLZT and ZrO{sub 2} phases. Using electrical impedance spectroscopy, the resonance frequencies of the composite system have been determined and analyzed. As the Al{sub 2}O{sub 3} volume fractions increase, the resonance frequency and the amplitude of the electrical response both decrease. An interpretation of the role of Al{sub 2}O{sub 3} additions is ...

2003-01-15

143

Magnetic properties of a SmNiSn single crystal  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and ...

2003-04-01

144

Ultrasensitive laser isotope analysis in an ion-storage ring  

Energy Technology Data Exchange (ETDEWEB)

We propose a novel method for ultrasensitive isotope analysis that combines magnetic mass selection, resonant charge-exchange neutralization, and resonant laser ionizaion. Our method attains high isotopic abundance selectivity by means of continuous multistage separation of ions stored in a small ring. For the environmentally interesting case of /sup 90/Sr versus /sup 88/Sr we estimate that sensitivity better than 10/sup -15/ for a throughput of 10/sup 13/ atoms/sec and an efficiency (after the ion source) greater than 10% are readily achievable.

1985-09-01

145

Trapping of neutral atoms with resonant microwave radiation  

Energy Technology Data Exchange (ETDEWEB)

We duscuss a resonant microwave trap for neutral atoms. Because of the long spontaneous radiation time this trap is remarkably different from the optical trap. It also has advantages over static magnetic traps that trap the excited spin state of the lowest electronic level, in that atoms predominantly in the spin ground state can be trapped. We analyze the relaxation-ejection lifetime of atoms in such a trap using the formalism of dressed atomic states. Results are appliedi to atomic hydrogen and the possibility of Bose-Einstein condensation is considered.

1989-05-15

146

Multiple resonances and Coulomb blockade splitting in a quantum dot-DNA composite  

British Library Electronic Table of Contents (United Kingdom)

Inspired by the recent realizations of quantum dot (QD)-DNA conjugation, we study the spectral density of a magnetic impurity coupled to a mesoscopic semiconducting host. Using a combination of exact diagonalization technique and an analytic approach, we demonstrate that various types of resonances occur according to the relative position of impurity levels (IL) with respect to the host levels (HL). While the usual Coulomb peaks appear when the IL lie inside a band gap, with IL approaching HL and hybridization activated, they shift nonlinearly with the repulsion strength and even undergo splitting for a strong hybridization. When IL merge into HL, multiple resonances of a comblike structure are found along with a parity effect.

2011-01-01

147

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

148

Primary cutaneous Ewing's sarcoma/primitive neuroectodermal tumor manifesting numerous small and huge ulcerated masses: its complete remission by chemotherapy and magnetic resonance imaging findings  

International Nuclear Information System (INIS)

Extraskeletal Ewing's sarcoma (ES) and primitive neuroectodermal tumor (PNET) are widely regarded as clinically and histologically identical tumors which consist of small blue round cells. Extraskeletal ESs/PNETs usually occur in the deep soft tissues of the paraspinal region, chest wall, or lower extremities. However, superficially located cases, so-called cutaneous ESs/PNETs, are exceedingly rare, and the vast majority of the reported cases present as a single small mass. We present magnetic resonance imaging (MRI) findings and clinical course of a unique case of primary cutaneous ES/PNET presenting as numerous huge masses with severe ulceration on them. (orig.)

2010-06-01

149

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

150

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection of joint diseases ...

151

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

152

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line ...

2002-08-01

153

Electron cyclotron current drive at {omega} approx. = {omega}{sub c} with X-mode launched from the low field side  

Energy Technology Data Exchange (ETDEWEB)

The electron cyclotron resonance layer in a tokamak, {omega}={omega}{sub c}(r), is not accessible by the extraordinary wave from the low field side, because it is shielded by a cutoff layer. However, a X-mode launched with a nonzero toroidal angle propagates at the cutoff parallel to the magnetic field and has a circular polarization. Therefore it can already at the cutoff layer interact efficiency with electrons via the Doppler shifted resonance. The driven current can be substantially higher than that driven by the second harmonic X-mode. The applicability of this current drive scheme is limited to rather low values of {omega}{sub p}{sup 2}/{omega}{sub c}{sup 2}, but may be of interest for high magnetic field devices. (author)

2000-02-01

154

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

155

Assessment of GABARAP self-association by its diffusion properties  

Energy Technology Data Exchange (ETDEWEB)

Gamma-aminobutyric acid type A receptor-associated protein (GABARAP) belongs to a family of small ubiquitin-like adaptor proteins implicated in intracellular vesicle trafficking and autophagy. We have used diffusion-ordered nuclear magnetic resonance spectroscopy to study the temperature and concentration dependence of the diffusion properties of GABARAP. Our data suggest the presence of distinct conformational states and provide support for self-association of GABARAP molecules. Assuming a monomer-dimer equilibrium, a temperature-dependent dissociation constant could be derived. Based on a temperature series of {sup 1}H{sup 15}N heteronuclear single quantum coherence nuclear magnetic resonance spectra, we propose residues potentially involved in GABARAP self-interaction. The possible biological significance of these observations is discussed with respect to alternative scenarios of oligomerization.

2010-09-15

156

Methods of reducing magnetic field near the transmission lines  

International Nuclear Information System (INIS)

Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.

2003-01-01

157

Anisotropic Nd{endash}Fe{endash}B bonded magnets made from HDDR powders (invited)  

Energy Technology Data Exchange (ETDEWEB)

Anisotropic Nd{endash}Fe{endash}B magnet powders can be produced by the hydrogenationdecomposition-desorption-recombination (HDDR) process from Nd{endash}Fe@ xnB{endash}Co{endash}M ({ital M}=Ga, Zr, Nb, Hf, and Ta) alloys. The present status of those HDDR powders and the bonded magnets made from them are reviewed with regards to the powder particle size dependence of their magnetic properties, their magnetic thermal stability, and their magnetization behavior. The results of a mechanistic study on the recombination step are also presented. The magnetic properties of the anisotropic HDDR powder depend relatively little on the powder particle size. Bonded magnets with a density of {approximately}6.20 g/cm{sup 3} and a BH{sub max} of 18.5{endash}20.5 MGOe can be produced from anisotropic HDDR powders with particle sizes of below 300 {mu}m diam. ...

1996-04-01

158

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

159

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research ...

160

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high ...

2008-06-01

161

Treatment of low-frequency pulsating magnetic field on amorphous alloy Fe_7_8Si_9B_1_3  

International Nuclear Information System (INIS)

Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe_7_8Si_9B_1_3 were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe_7_8Si_9B_1_3. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase (#alpha#-Fe(Si), the grain ...

2007-07-15

162

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC ...

1980-03-01

163

Numerical study of Cosmic Ray Diffusion in MHD turbulence  

CERN Document Server

We study diffusion of Cosmic Rays (CRs) in turbulent magnetic fields using test particle simulations. Electromagnetic fields are produced in direct numerical MHD simulations of turbulence and used as an input for particle tracing, particle feedback on turbulence being ignored. Statistical transport coefficients from the test particle runs are compared with earlier analytical predictions. We find qualitative correspondence between them in various aspects of CR diffusion. In the incompressible case, that we consider in this paper, the dominant scattering mechanism occurs to be the non-resonant mirror interactions with the slow-mode perturbations. Perpendicular transport roughly agrees with being produced by magnetic field wandering.

2010-01-01

164

Resistivity, Hall effect, and magnetic susceptibility of UPd_2Si_2  

International Nuclear Information System (INIS)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

165

Resistivity, Hall effect, and magnetic susceptibility of UPd[sub 2]Si[sub 2  

Energy Technology Data Exchange (ETDEWEB)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

1993-12-15

166

Photoelectron resonance capture ionization mass spectrometry: a soft ionization source for mass spectrometry of particle-phase organic compounds.  

Science.gov (United States)

Photoelectron resonance capture ionization (PERCI) is a soft and sensitive ionization method, based on the attachment of low-energy (<1 eV) photoelectrons to organic analyte molecules. PERCI has been developed in our laboratory for the real-time analysis of organic particles by mass spectrometry, and is employed here to monitor the heterogeneous reaction of ozone with oleic acid. Simplified identification of the reaction products is possible as a result of the soft nature of PERCI, giving predominantly the [M--H](-) ions. The major particle-phase products are identified as: 1-nonanal, nonanoic acid, 9-oxononanoic acid, and azelaic acid, consistent with proposed mechanisms. New insight into this well-studied heterogeneous reaction is gained as additional minor particle-phase products, consistent with the Criegee mechanism, are readily detected. PMID:15468105

2004-01-01

167

Roles of the #beta# 146 histidyl residue in the molecular basis of the Bohr Effect of hemoglobin: A proton nuclear magnetic resonance study  

International Nuclear Information System (INIS)

Assessment of the roles of the carboxyl-terminal #beta#146 histidyl residues in the alkaline Bohr effect in human and normal adult hemoglobin by high-resolution proton nuclear magnetic resonance spectroscopy requires assignment of the resonances corresponding to these residues. By a careful spectroscopic study of human normal adult hemoglobin, enzymatically prepared des(His146#beta#)-hemoglobin, and the mutant hemoglobins Cowtown (#beta#146His #-># Leu) and York (#beta#146His #-># Pro), the authors have resolved some of these conflicting results. By a close incremental variation of pH over a wide range in chloride-free 0.1 M N-(2-hydroxyethyl)piperazine-N'-2-ethanesulfonic acid buffer, a single resonance has been found to be consistently missing in the proton nuclear magnetic resonance spectra of these hemoglobin variants. The results indicate that the ...

168

Anti-cancer drug loaded iron-gold core-shell nanoparticles (Fe@Au) for magnetic drug targeting.  

Science.gov (United States)

Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus ...

2010-09-01

169

Heat transfer of lithium single-phase flow and helium-lithium two-phase flow in a circular channel under transverse magnetic field  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of pressure drop and heat transfer have been investigated for a lithium single-phase flow and a helium-lithium two-phase flow in a horizontal conducting circular channel in the presence of a uniform transverse magnetic field up to 1.4 T as related to the lithium cooling for magnetic-confinement fusion reactors. By the application of the magnetic field to the lithium single-phase flow, remarkable heat transfer enhancement has been observed at the top wall due to the suppression of the mixed convection occurring in the low Peclet number range, while appreciable heat transfer deterioration appeared in the high Peclet number range. It has been confirmed that the helium-lithium two-phase flow can reduce the high magnetohydrodynamic (MHD) pressure drop in a lithium single-phase flow, and it can provide much ...

1998-09-01

170

The brain-derived neurotrophic factor Val66Met polymorphism is associated with reduced functional magnetic resonance imaging activity in the hippocampus and increased use of caudate nucleus-dependent strategies in a human virtual navigation task  

UK PubMed Central (United Kingdom)

Multiple memory systems are involved in parallel processing of spatial information during navigation. A series of studies have distinguished between hippocampus-dependent ‘spatial’ navigation,...Full Text Available

2011-03-01

171

Structure of a mycobacterial polysaccharide-fatty acyl-CoA complex: nuclear magnetic resonance studies.  

UK PubMed Central (United Kingdom)

MMP, a linear alpha 1 leads to 4 linked polymer of 3-O-methylmannose, regulates the fatty acid synthetase from Mycobacterium smegmatis by forming stoichiometric complexes with the long-chain acyl-CoA...Full Text Available

1980-05-01

172

Right-sided invasive metastatic thymoma of the heart  

British Library Electronic Table of Contents (United Kingdom)

Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.

2011-01-01

173

Quality control in Nuclear Magnetic Resonance Imaging. Indications et strategies pour le controle de qualite en IRM  

Energy Technology Data Exchange (ETDEWEB)

In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.

1993-01-01

174

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

175

Metastatic Ewing's sarcoma to the skull: CNS involvement excluded by MRI  

International Nuclear Information System (INIS)

A case of metastatic Ewing's sarcoma to the skull is presented, demonstrating the superiority of magnetic resonance imaging over other imaging modalities to exclude CNS involvement. Precise delineation of different tumor components in extradural location contained in an intact dural rim together with compressed cortex showing no signs of tumorous involvement constituted an MRI appearance allowing us to exclude tumor outgrowth into the brain. (orig.).

176

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

177

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

178

MRI and 1H MRS of The Breast: Presence of a Choline Peak as Malignancy Marker is Related to k21 Value of the Tumor in Patients with Invasive Ductal Carcinoma  

UK PubMed Central (United Kingdom)

To assess which specific morphologic features, enhancement patterns, or pharmacokinetic parameters on breast Magnetic Resonance Imaging (MRI) could predict a false-negative outcome of Proton...Full Text Available

2008-01-01

179

MR findings of primary Ewing's sarcoma of greater wing of sphenoid  

International Nuclear Information System (INIS)

Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd

2002-12-01

180

Hyperfine interactions in HCOOD and DCOOH molecules  

Energy Technology Data Exchange (ETDEWEB)

The method of double microwave--radio-frequency resonance has been used to obtain spectra of the 2/sub 11/reverse arrow2/sub 12/ and 3/sub 21/reverse arrow3/sub 22/ transitions in HCOOD, DCOOH, and HCOOH molecules. The constants of the quadrupole bond of the deuterons have been determined, magnetic interactions being taken into acocunt. A comparison with results of previous studies is given.

1986-05-01

181

Effect of Elicitation and Changes in Extracellular pH on the Cytoplasmic and Vacuolar pH of Suspension-Cultured Soybean Cells 1  

UK PubMed Central (United Kingdom)

We have employed both 31P nuclear magnetic resonance spectroscopy and two intracellular fluorescent pH indicator dyes to monitor the pH of the vacuole and cytoplasm of suspension-cultured...Full Text Available

1992-02-01

182

Characterization of polymers for microcellular foams  

Energy Technology Data Exchange (ETDEWEB)

We have measured, by {sup 1}H and {sup 13}C nuclear magnetic resonance (NMR), the percent deuteration, the tacticity and the purity of several polymers and one solvent used in the preparation of microcellular foams. The percent deuteration was measured for polystyrene, polyacrylonitrile and polyethylene. The tacticities of polystyrene and polyacrylonitrile were determined. The purity and degradation products of polyacrylonitrile and maleic anhydride were examined. This report documents the experimental procedures and results of these measurements.

1992-03-01

183

31P NMR Observations on the Effect of the External pH on the Intracellular pH Values in Plant Cell Suspension Cultures 1  

UK PubMed Central (United Kingdom)

31P nuclear magnetic resonance (NMR) spectroscopy was used to monitor the response of oil palm (Elaeis guineensis) and carrot (Daucus carota) cell suspensions...Full Text Available

1990-06-01

184

Spatial Damping of Propagating Kink Waves Due to Resonant Absorption: Effect of Background Flow  

CERN Document Server

Observations show the ubiquitous presence of propagating magnetohydrodynamic (MHD) kink waves in the solar atmosphere. Waves and flows are often observed simultaneously. Due to plasma inhomogeneity in the perpendicular direction to the magnetic field, kink waves are spatially damped by resonant absorption. The presence of flow may affect the wave spatial damping. Here, we investigate the effect of longitudinal background flow on the propagation and spatial damping of resonant kink waves in transversely nonuniform magnetic flux tubes. We combine approximate analytical theory with numerical investigation. The analytical theory uses the thin tube (TT) and thin boundary (TB) approximations to obtain expressions for the wavelength and the damping length. Numerically, we verify the previously obtained analytical expressions by means of the full solution of the resistive MHD eigenvalue problem beyond the TT ...

2011-01-01

185

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists ...

1991-09-15

186

Strength functions of primary transitions following thermal neutron capture in strontium  

Energy Technology Data Exchange (ETDEWEB)

The primary E1, M1 and E2 ..gamma..-radiation in /sup 87,88,89/Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, ..gamma..) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for /sup 90/Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models.

1989-04-01

187

Strength functions of primary transitions following thermal neutron capture in strontium  

International Nuclear Information System (INIS)

The primary E1, M1 and E2 #gamma#-radiation in "8"7","8"8","8"9Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, #gamma#) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for "9"0Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models. ...

188

Magnetic microstructure of candidates for epitaxial dual Heusler magnetic tunnel junctions  

Energy Technology Data Exchange (ETDEWEB)

Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.

2009-05-15

189

Nuclear magnetic resonance on oriented "1"7"5Ta and "1"7"7Ta  

International Nuclear Information System (INIS)

"1"7"5Ta and "1"7"7Ta nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies #nu#="+#mu#B sub(HF)/Ih"+ of the "1"7"5Ta and "1"7"7Ta ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of "1"8"1Ta in Fe, the magneticmoments have been deduced: "+#mu#("1"7"5Ta, 7/2"+)"+=2.270(45) and "+#mu#("1"7"7Ta, 7/2"+)"+=2.250(45)#mu# sub(N). These values of the magnetic moments are discussed in the framework of the rotational model. (author).

190

Enzymatic synthesis and carbon-13 nuclear magnetic resonance conformational studies of disaccharides containing. beta. -D-galactopyranosyl and. beta. -D-(1-/sup 13/C)Galactopyranosyl residues  

Energy Technology Data Exchange (ETDEWEB)

Partially purified UDPgalactosyltransferase (EC 2.4.1.22) from bovine milk has been used to synthesize millimolar amounts of compounds such as Gal..beta..(1..-->..4)Glc, Gal..beta..(1..-->..4)GlcNAc-..beta..-hexanolamine, and Gal..beta..(1..-->..4)-GlcNAc..beta..(1..-->..4)GlcNAc. The same method has been used to prepare similar compounds containing /sup 13/C-enriched galactopyranosyl moieties. Gal..beta..(1..-->..4)GlcNAc-..beta..-hexanolamine was also synthesized in a solid-phase system in which the GlcNAc-..beta..-hexanolamine glycoside was covalently linked to agarose beads. At pH 7.0 and at 1 to 5 mM Mn/sup 2 + +/ the yields of the galactosyl saccharides are greater than 90% by using 10% excess of UDPGal donor. The use of a 90% enriched (1-/sup 13/C)galactosyl residue allowed the determination of the most abundant conformer about the galactopyranosyl-glycoside linkage by analysis of the carbon-carbon coupling constants from Cl to Gal to the ...

1980-02-05

191

Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy  

International Nuclear Information System (INIS)

High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 deg. C voxel-wise SDT) ...

2008-11-21

192

Multiple ordered phases in the filled skutterudite compound PrOs4As12  

Energy Technology Data Exchange (ETDEWEB)

Magnetization, specific heat, and electrical resistivity measurements were made on single crystals of the filled skutterudite compound PrOs{sub 4}As{sub 12}. Specific heat measurements indicate an electronic specific heat coefficient {gamma} {approx} 50-200 mJ/mol K{sup 2} at temperatures 10 K {le} T {le} 18 K, and {approx} 1 J/mol K{sup 2} for t {le} 1.6 K. Magnetization, specific heat, and electrical resistivity measurements reveal the presence of two, or possibly three, ordered phases at temperatures below {approx} 2.3 K and in fields below {approx} 3 T. The low temperature phase displays antiferromagnetic characteristics, while the nature of the ordering in the other phase(s) has yet to be determined.

2006-03-20

193

Optical Feshbach Resonances in Alkaline Earth Atoms  

Science.gov (United States)

Recent proposals have shown that a quantum degenerate gas of alkaline earth atoms can be used for a number of novel quantum computing and quantum simulation experiments. Strontium is a good candidate for such experiments because it can be controlled with high precision, as demonstrated in recent atomic clock experiments. Unfortunately, the small scattering length of strontium is not amenable to evaporative cooling techniques that are used to reach quantum degeneracy. Furthermore, increasing the scattering length of alkaline earths with a magnetic Feshbach resonance is not possible due to their spinless electronic ground state configuration. However, recent theoretical and experimental work suggests the possibility of changing scattering lengths in alkaline earths with laser light. Using this optical Feshbach resonance near strontium's narrow ^1S0->^3P1 intercombination transition might allow its scattering length to be ...

2009-10-01

194

Nuclear quadrupole resonance of "9"3Nb in intermetallic compounds with A-15 crystal strucutre  

International Nuclear Information System (INIS)

The impulse method has been used to study "9"3Nb (nuclear quadrupole resonance (NQR) parameters quadrupole connection constant, spin-lattice and spin-spin relaxation times) in binary intermetallic compounds of Nb_3X (x=Al, Ga, Ge, Sn, Pt, Os, Ir, Sb) and in some ternary phases on the basis of the Nb_3Al compound. The discussion on experimental data obtained is carried out in approximation of a tight connection for d-electrons.

1981-02-01

195

Proton spin lattice relaxation studies in lithium ammonium sulfate LiNH_4SO_4  

International Nuclear Information System (INIS)

Lithium ammonium sulfate (LAS) undergoes a phase transition at Tsub(c1) = 459.5deg K from a paraelectric phase (phase 1) to a ferroelectric phase (phase II) and again at Tsub(c2) = 283deg K to a polar ferroelastic phase (phase III). Proton spin lattice relaxation investigations in the temperature range 480-77deg K at 10 MHz show discontinuous changes in Tsub(1) at the transition temperatures, indicating first order phase transitions. The absence of the slow motion region (#omega#sub(not)tausub(not)>>1) shows that the ammonium ions are reorienting fast enough to keep the resonance absorption line narrow down to liquid nitrogen temperatures. The possibility of a second minimum and a low activation energy, Esub(a) = 2.659 kcal/mole, in phase III suggest the possibility of ...

1978-12-31

196

Temperature evolution of the internal magnetic hyperfine field of Metglas: amorphous and crystallized phases  

International Nuclear Information System (INIS)

We present differential scanning calorimetry (DSC), X-ray diffractometry, in situ Moessbauer spectroscopy (MS), and transmission electron microscopy (TEM) studies in Metglas ribbons subjected to different heat treatments. The temperature evolution of the hyperfine field H_h_f(T) and the Curie temperature (T_c) of the amorphous phase are determined. The magnetic field originally present in the amorphous phase has a 'normal' behavior, in the sense that it can be described by the Weiss molecular field theory. The total angular momentum of the iron atoms turns out to be 5/2 and this implies Fe"3"+ in which the electronic spins are uncoupled. When the samples are maintained near T_c (#approx#673 K), three new magnetic phases are detected in the Moessbauer spectra, indicating an onset of a crystallization process well below the first crystallization temperature (T_X_1), as determined by ...

2000-11-01

197

Heat transfer and hydraulics of liquid metal-gas two-phase magnetohydrodynamic flow  

International Nuclear Information System (INIS)

Local properties and heat transfer have been investigated in a NaK-nitrogen two-phase flow in a vertical tube under transverse magnetic field. An objective two-phase flow regime identification was also carried out systematically, using the probability distribution function of two-phase electromagnetic flowmeter signals. The application of a magnetic field was bound to bring about a drastic change in the void fraction profile, i.e., asymmetric profile perpendicular to the field direction. This effect was more remarkably observed in bubbly flows. The magnetic field was also observed to decrease the number of bubbles, by promoting the agglomeration of small bubbles into larger ones and also break-up of large slugs, and, thus, to shift the flow regime boundaries. It has been also shown that the two-phase Nusselt number increases in bubbly flows, ...

1986-08-01

198

Lack of oscillations in Dual-Phase-Lagging heat conduction for a porous slab subject to imposed heat flux and temperature  

Energy Technology Data Exchange (ETDEWEB)

This study shows that the physical conditions necessary for thermal waves to materialize in Dual-Phase-Lagging porous media conduction are not attainable in a porous slab subject to a combination of constant heat flux and temperature (Neumann and Dirichlet) boundary conditions. It is demonstrated that the approximate equivalence between Dual-Phase-Lagging (DuPhlag) heat conduction model and the Fourier heat conduction in porous media subject to Lack of Local Thermal Equilibrium (La Lotheq) that suggested the possibility of thermal oscillations and resonance reveals a condition that cannot be fulfilled because of physical constraints. (author)

2005-07-01

199

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the ...

1998-05-01

200

The magnetic resonance and its agro-industry applications; a review  

International Nuclear Information System (INIS)

The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage and conservation of ...

201

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

202

Effect of magnetic field and pressure on U(Ni_1_-_xPd_x)_2Si_2 single crystals  

International Nuclear Information System (INIS)

Single crystals of U(Ni_1_-_xPd_x )_2Si_2 for x = 0.05, 0.10 and 0.15 have been grown. Magnetization and electrical resistivity measurements were performed in a wide range of temperatures, magnetic fields and high pressures in order to study stability of magnetic phases in the solid solutions between UNi_2Si_2 and UPd_2Si_2 with a special emphasis on the type of ground state. In UPd_2Si_2 the simple AFI-type antiferromagnetic structure of U moments is observed at low temperatures. UNi_2Si_2 adopts the uncompensated AF structure (UAF) with the ++- stacking of U moments along the c-axis and consequently this compound exhibits a spontaneous magnetization corresponding to 1/3 of the U moment. The substitution of Pd for Ni leads to a rapid decay of the spontaneous magnetization. The evolution of magnetization and electrical resistivity behavior ...

2002-07-01

203

Transition-metal dimers and physical limits on magnetic anisotropy  

British Library Electronic Table of Contents (United Kingdom)

Recent advances in nanoscience have raised interest in the minimum bit size required for classical information storage. This bit size is determined by the necessity for bistability with suppressed quantum tunnelling and energy barriers that exceed ambient temperatures. In the case of magnetic information storage, much attention has centred on molecular magnets with bits consisting of about 100 atoms, magnetic uniaxial anisotropy energy barriers of about 50?K and very slow relaxation at low temperatures. Here, we draw attention to the remarkable magnetic properties of some transition-metal dimers, which have energy barriers approaching 500?K with only two atoms. The spin dynamics of these ultrasmall nanomagnets is strongly affected by a Berry phase, which arises from quasi-degen...

2007-01-01

204

Science of quantum phase transitions and quantum criticalities  

International Nuclear Information System (INIS)

Apart from conventional phase transitions driven by the thermal effects, quantum phase transitions generated by quantum fluctuations have their own mechanisms that are reflected in critical phenomena. Quantum phase transitions have an origin from spontaneous symmetry breaking commonly to thermal phase transitions. Even in this case, inherent quantum fluctuations substantially modify and yield new aspects. Quantum phase transitions have, however, another mechanism caused by topology changes, which gives completely new characters. Recently, a mechanism which connects these two has been found. Proimities from first-order transitions and phase separatins as well as from multiphase coexistence also generate characteristic and unconventional quantum criticalities. Understanding novel quantum criticalities offers a firm basis of recent active researches on fields such ...

2011-02-01

205

Hydrogen in metals  

International Nuclear Information System (INIS)

An important application of metal hydrides is as a moderator material in nuclear reactors. The fundamental properties of hydrides are illustrated and an impression given of the current research into hydrogen in transition metals. Phase diagrams, magnetic properties, temperature dependence of the diffusion coefficient, energy level schemes and superconductivity are considered. (C.F.).

206

Emergent magnetic moments produced by self-damage in plutonium  

UK PubMed Central (United Kingdom)

Plutonium possesses the most complicated phase diagram in the periodic table, driven by the complexities of overlapping 5f electron orbitals. Despite the importance of the 5f...Full Text Available

2006-11-14

207

Drift compression and final focus of intense heavy ion beams  

Energy Technology Data Exchange (ETDEWEB)

The longitudinal and transverse dynamics of a heavy ion fusion beam during the drift compression and final focus phase is studied. A lattice design with four time-dependent magnets is described that focuses the entire beam pulse onto a single focal point with the same spot size.

2003-05-01

208

Effect of chemical composition on the structure and mechanical properties of Mn-Al-C alloys in the magnetic region  

Energy Technology Data Exchange (ETDEWEB)

The thermal stability and deformability of Mn-Al-C alloys containing 0.6 pct C are investigated experimentally as a function of excess phase content. It is shown that an increase in Mn content from 68.9 to 73.5 pct leads to increased stability of the high-temperature epsilon phase. The enrichment of the system Mn-Al-Cu in Mn and Al above the optimum composition leads to the formation of nonmagnetic excess phases, eta and beta, which reduce the magnetization of the alloy. In addition, a decrease in thermal stability is observed in the alloy with 73.5 pct Mn due to the decomposition of the ferromagnetic phase. 7 references.

1988-01-01

209

Radiation and thermal analysis of superconducting quadrupoles in the interaction region of linear collider  

Energy Technology Data Exchange (ETDEWEB)

CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.

2008-06-01

210

Preparation of NiZn-ferrite nanofibers by electrospinning for DNA separation  

Energy Technology Data Exchange (ETDEWEB)

We present the synthesis, magnetic and UV spectrometry of NiZn-ferrite nanofiber. The single phase of spinel ferrite was obtained at 600 {sup o}C. The NiZn-ferrite fibers fabricated by an electrospinning process were formed as a polygonal grain growth with firing temperature in fiber matrix. It appeared that the saturation magnetization (M{sub S}) of NiZn-ferrite nanofiber was dependent on Ni/Zn molar ratio which is similar to that of the inverse spinel ferrites. The NiZn-ferrite fibers showed good DNA adsorption efficiency that can be modified and utilized for DNA separation with magnetic nanofiber as a novel material in clinical applications.

2009-05-15

211

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically ...

1997-01-01

212

Structural relaxation and crystallization in the Fe-Cr-Si-B and Fe-Cu-Cr-Si-B amorphous alloys  

International Nuclear Information System (INIS)

Structural relaxation, crystallization and optimisation processes in soft magnetic amorphous alloys based on iron are examined by applying different experimental techniques: X-ray diffraction analysis, high-resolution electron microscopy, measurements of magnetic and electric properties (permeability, after-effect resistivity). The presented results are discussed in terms of annealing out of microvoids, formation of nanocrystalline phase and changes of effective magnetostriction constant. (author)

2001-09-23

213

One-dimensional numerical simulation of free-electron laser (FEL) amplifier with incorporate variable-parameter wiggler magnets  

International Nuclear Information System (INIS)

A physical model of free-electron laser (FEL) amplifier with variable-parameter wiggler magnets for one-dimensional numerical simulation is presented and a numerical example is given. The wiggler parameters, efficiency of energy conversion between electron beam and laser field, laser intensity, phase-space distributions and energy spectrum of electrons are computed. The period of synchronous oscillation and saturation value of laser intensity agree with estimated one.

214

Magnetoresistance of Two-Dimensional Tight-Binding Electrons in a Weak Magnetic Field  

International Nuclear Information System (INIS)

We study the Anderson model on a two-dimensional square lattice with an applied weak magnetic field B which causes the hopping matrix elements to have Peierls phase factors. The recursion method is applied and B dependent conductivity ?(B) is calculated from the Kubo formula for different system sizes and degree of disorder W . For large W there is no systematic change of ?(B) with B, it shows a fluctuating behavior.

2008-08-25

215

[sup 1]H[[sup 27]Al] double-resonance experiments in solids. An unexpected observation in the [sup 1]H MAS spectrum of zeolite HZSM-5  

Science.gov (United States)

We report the existence of a previously unsuspected peak in the [sup 1]H magic angle spinning spectrum of commercially available HZSM-5 samples. At 298 K, this resonance is a broad shoulder on the downfield side of the Bronsted acid signal at 4.3 ppm. Cooling the sample caused the line to narrow, and a clear peak at 6.9 ppm was visible at 123 K. This technique resulted in selective broadening of the 4.3 and 6.9 ppm resonances as a result of conflicting averaging of the [sup 1]H-[sup 27]Al dipolar coupling. We conclude that the 6.9 ppm resonance corresponds to a novel aluminum-containing site in zeolite HZSM-5 and is not an artifact due to exchange with the Bronsted site or an aluminum-rich impurity phase. A possible interpretation of these results is a second Bronsted site for the zeolite. 49 refs., 8 figs.

1994-10-19

216

Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider  

Energy Technology Data Exchange (ETDEWEB)

Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations ...

2005-09-18

217

Acoustic metamaterials for sound focusing and confinement  

Energy Technology Data Exchange (ETDEWEB)

We give a theoretical design for a locally resonant two-dimensional cylindrical structure involving a pair of C-shaped voids in an elastic medium which we term as double 'C' resonators (DCRs) and imbedded thin stiff bars, that displays the negative refraction effect in the low frequency regime. DCRs are responsible for a low frequency band gap which hybridizes with a tiny gap associated with the presence of the thin bars. Using an asymptotic analysis, typical working frequencies are given in closed form: DCRs behave as Helmholtz resonators modeled by masses connected to clamped walls by springs on either side, while thin bars behave as a periodic bi-atomic chain of masses connected by springs. The discrete models give an accurate description of the location and width of the stop band in the case of the DCR and the first two dispersion bands for the periodic thin bars. We then combine our asymptotic ...

2007-11-15

218

Acoustic metamaterials for sound focusing and confinement  

International Nuclear Information System (INIS)

We give a theoretical design for a locally resonant two-dimensional cylindrical structure involving a pair of C-shaped voids in an elastic medium which we term as double 'C' resonators (DCRs) and imbedded thin stiff bars, that displays the negative refraction effect in the low frequency regime. DCRs are responsible for a low frequency band gap which hybridizes with a tiny gap associated with the presence of the thin bars. Using an asymptotic analysis, typical working frequencies are given in closed form: DCRs behave as Helmholtz resonators modeled by masses connected to clamped walls by springs on either side, while thin bars behave as a periodic bi-atomic chain of masses connected by springs. The discrete models give an accurate description of the location and width of the stop band in the case of the DCR and the first two dispersion bands for the periodic thin bars. We then combine our asymptotic formulae for arrays of ...

2007-11-01

219

Evolution of magnetic structures in the UNi{sub 2}Si{sub 2}-UPd{sub 2}Si{sub 2} system  

Energy Technology Data Exchange (ETDEWEB)

The influence of Pd-Ni substitution on the formation of magnetic phases in the tetragonal U(Ni{sub 1-x}, Pd{sub x}){sub 2}Si{sub 2} system and the concentration magnetic phase diagram are presented. A series of different substitutions was prepared and detailed studies by powder neutron diffraction were performed for x=0.25, 0.5 and 0.75. All compounds order antiferromagnetically and form ferromagnetic basal planes stacked along the c axis (q=(0,0,q{sub z}) propagation). The ground-state phase (AF3) of UNi{sub 2}Si{sub 2} is an uncompensated AF structure (++- stacking (q{sub z}=2/3)). In UPd{sub 2}Si{sub 2} the ground-state phase corresponds to the simple AF structure AF2 (+-+-(q{sub z}=1)). In solid solutions, no traces of the AF3 phase were found for x=0.25 and the ground-state powder patterns correspond to AF2 for x{>=}0.25. (orig.)

2002-07-01

220

Evolution of magnetic structures in the UNi_2Si_2-UPd_2Si_2 system  

International Nuclear Information System (INIS)

The influence of Pd-Ni substitution on the formation of magnetic phases in the tetragonal U(Ni_1_-_x, Pd_x)_2Si_2 system and the concentration magnetic phase diagram are presented. A series of different substitutions was prepared and detailed studies by powder neutron diffraction were performed for x=0.25, 0.5 and 0.75. All compounds order antiferromagnetically and form ferromagnetic basal planes stacked along the c axis (q=(0,0,q_z) propagation). The ground-state phase (AF3) of UNi_2Si_2 is an uncompensated AF structure (++- stacking (q_z=2/3)). In UPd_2Si_2 the ground-state phase corresponds to the simple AF structure AF2 (+-+-(q_z=1)). In solid solutions, no traces of the AF3 phase were found for x=0.25 and the ground-state powder patterns correspond to AF2 for x#>=#0.25. (orig.)

221

Low-frequency fields - sources and exposure; Niederfrequente Felder - Quellen und Exposition  

Energy Technology Data Exchange (ETDEWEB)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe) [Deutsch] Nach einer kurzen Diskussion der Begriffsdefinitionen und einer Einfuehrung in die Messtechnik werden die Charakteristika verschiedener ...

1993-06-01

222

Disturbance Rejection Control of an Electromagnetic Bearing Spindle  

Energy Technology Data Exchange (ETDEWEB)

The force exerted on the rotor by an active magnetic bearing (AMB) is determined by the current flow in the magnet coils. This force can be controlled very precisely, making magnetic bearings a potential benefit for grinding, where cutting forces act as external disturbances on the shaft, resulting in degraded part finish. It is possible to achieve precise shaft positioning, reduce vibration of the shaft caused by external disturbances, and even damp out resonant modes. Adaptive control is an appealing approach for these systems because the controller can tune itself to account for an unknown periodic disturbance, such as cutting or grinding forces, injected into the system. In this paper the authors show how one adaptive control algorithm can be applied to an AMB system with a periodic disturbance applied to the rotor. An adaptive algorithm was developed and implemented in both simulation and hardware, ...

2000-08-31

223

Anisotropic magnetism in hybridizing uranium systems  

International Nuclear Information System (INIS)

The isostructural uranium monopnictides and monochalcogenides have become prototype systems in actinide research with respect to their unusual magnetic properties. We have investigated the origins in the electronic structure of the variation in magnetic behavior as the degree of 5f-electron localization changes from localized to itinerant on going up the pnictogen or chalcogen column, thus decreasing the U-U separation. We have applied a synthesis of: (1) A phenomenological theory of orbitally driven magnetic ordering which includes both the hybridization-induced and the RKKY exchange interactions on an equal footing, and (2) Ab initio electronic structure calculations, based on the linear-muffin-tin-orbital method, allowing a first-principles evaluation of the parameters entering the model Hamiltonian. We have investigated systematically characteristic trends and changes of the 5f-state resonance ...

224

Phase diagram and low temperature magnetization of Gdsub(x)Ysub(1-x)Rh_4B_4  

International Nuclear Information System (INIS)

The phase diagram of Gdsub(x)Ysub(1-x)Th_4B_4 between the paramagnetic, superconducting and ferromagnetic state is reported. Low temperature dc-magnetization measurements reveal that macroscopic electro-magnetic effects are of minor importance for the suppression of Hsub(2c), which shows a smooth bell-shaped behavior for x >= 0.15 with no indication of an anomaly near Tsub(c2). At low temperature in samples with x >= 0.20 a transition from type II to type I superconductivity seems to occur. The low temperature normal state susceptibility follows a Curie-Weiss law indicating reentrant behavior for x >= 0.10. (orig.).

1981-09-01

225

Magnetic structures and magnetocrystalline anisotropy in bulk and thin film Fe_3Pt  

International Nuclear Information System (INIS)

Magnetic structures and magnetocrystalline anisotropy (MCA) of tetragonal phase Fe_3Pt with an L1_2 atomic ordering in bulk and thin film are investigated by means of the first-principles full-potential linearized augmented plane-wave method. The results obtained predict that the tetragonal phase, in which the tetragonal distortion with (c/a) = 0.95 makes an asymmetry of magnetic properties along the c-axis (out-of-plane) and a-axis (in-plane), has an out-of-plane MCA. In addition, from the thin film calculations, the presence of surface is found to strongly enhance the out-of-plane MCA.

2008-09-30

226

Spiral modes in the diffusion of a single granular particle on a vibrating surface  

International Nuclear Information System (INIS)

We consider a particle that is subject to a constant force and scatters inelastically on a vibrating periodically corrugated floor. At small friction and for small scatterers the dynamics is dominated by resonances forming spiral structures in phase space. These spiral modes lead to pronounced maxima and minima in the diffusion coefficient as a function of the vibration frequency, as is shown in computer simulations. Our theoretical predictions may be verified experimentally by studying transport of single granular particles on vibratory conveyors.

2004-11-29

227

Test Bed for Superconducting Materials  

Energy Technology Data Exchange (ETDEWEB)

Superconducting rf cavities are increasingly used in accelerators. Gradient is a parameter of particular importance for the ILC. Much progress in gradient has been made over the past decade, overcoming problems of multipacting, field emission, and breakdown triggered by surface impurities. However, the quenching limit of the surface magnetic field for niobium remains a hard limitation on cavity fields sustainable with this technology. Further exploration of materials and preparation may offer a path to surpassing the current limit. For this purpose, we have designed a resonant test cavity. One wall of the cavity is formed by a flat sample of superconducting material; the rest of the cavity is copper or niobium. The H field on the sample wall is 75% higher than on any other surface. Multipacting is avoided by use of a mode with no surface electric field. The cavity will be resonated through a coupling iris with high-power rf ...

2006-01-30

228

Study of praseodymium complexing with ethylenediaminetetraacetic acid by proton magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

The method of proton magnetic resonance (PMR) has been used to study the mechanism of reaction of complexing of paramagnetic Pr/sup 3 +/ ion with ethylenediaminetetra acetic acid (EDTA). The influence of medium acidity (pH5-12), EDTA/Pr ratio varying from 1 to 50, Pr/sup 3 +/ ion concentration (from 5x10/sup -3/ to 3x10/sup -1/ g-ion/l) and temperature (8-98 deg C) on chemical shifts and broadening of signals of EDTA molecule protons is investigated. Data on ratio of components, coordination and stability of forming complexes are obtained. The existence of two types of complexes with the Pr/EDTA ratio equal to 1:1 and 1:2 has been found. Equimolecular complex (1:1) is stable all over the studied temperature interval in contrast to the complex 1:2 for which at 50 deg C fast extrasphere exchange (Pr EDTA)EDTA * + EDTA/sup 0/ reversible (PrEDTA)EDTA/sup 0/ + EDTA * is observed, while at t=98 deg C intrasphere exchange (PrEDTA)EDTA * reversible ...

1983-05-01

229

Proton magnetic resonance spectroscopy reflects cellular proliferative activity in astrocytomas  

International Nuclear Information System (INIS)

We examined whether proton magnetic resonance spectroscopy (MRS) could provide accurate information on histological grade and cell proliferation in astrocytomas. We studied 23 patients with astrocytomas: five grade II, 10 grade III and eight with grade IV (glioblastoma multiforme). We performed proton MRS and determined the Ki-67 labeling index (LI), a tumour proliferation marker, in the same areas of the astrocytomas, and examined the statistical relationship between proton MRS and Ki-67 LI. The N-acetylaspartate (NAA)/creatine-phosphocreatine (Cr) and NAA/choline (Cho)-containing compound ratios were always significantly lower and the Cho/Cr ratios significantly higher than those for normal brain. The Cho/Cr ratio correlated positively and the NAA/Cho ratio inversely with Ki-67 LI. These findings suggest that the Cho signal in proton MRS reflects cellular proliferation. In Kaplan-Meier survival analysis, there was no significant difference ...

2000-05-01

230

Monitoring of the insecticide trichlorfon by phosphorus-31 nuclear magnetic resonance ({sup 31}P NMR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Trichlorfon is an organophosphorus insecticide, which is extensively being used for protection of fruit crops. Trichlorfon is a thermal labile compound, which cannot be easily determined by gas chromatography (GC) and has no suitable group for sensitive detection by high performance liquid chromatography (HPLC). In this study, a {sup 31}P nuclear magnetic resonance ({sup 31}P NMR) has been described for monitoring of trichlorfon without any separation step. The quantitative works of {sup 31}P NMR spectroscopy has been performed in the presence of an internal standard (hexamethylphosphoramide). Limit of detection (LOD) for this method has been found to be 55 mg L{sup -1}, without any sample preparation, and the linear working range was 150-5500 mg L{sup -1}. Relative standard deviation (R.S.D.%) of the method for three replicates within and between days was obtained {<=}9%. The average recovery efficiency was approximately 99-112%. This ...

2006-08-25

231

Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)  

International Nuclear Information System (INIS)

Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...

232

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular regurgitation was easy to differentiate from ...

233

Magnetic resonance appearance of peripheral nerve sheath tumors  

International Nuclear Information System (INIS)

Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship between the lesions and the adjacent neurovascular structures and ...

234

Low field magnetic resonance imaging of femoral neck fractures  

International Nuclear Information System (INIS)

Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).

235

Effect of external pH on the cytoplasmic and vacuolar pHs in Mung bean root-tip cells. A T P nuclear magnetic resonance study  

Energy Technology Data Exchange (ETDEWEB)

The effect of the external pH on the intracellular pH in mung bean (Vigna mungo (L.) Hepper) root-tip cells was investigated with the T P nuclear magnetic resonance (NMR) method. The T P NMR spectra showed three peaks caused by cytoplasmic G-6-P, cytoplasmic Psub(i) and vacuolar Psub(i). The cytoplasmic and vacuolar pHs could be determined by comparing the Psub(i) chemical shifts with the titration curve. When the external pH was changed over a range from pH 3 to 10, the cytoplasmic pH showed smaller changes than the vacuolar pH, suggesting that the former is regulated more strictly than the latter. The H -ATPase inhibitor, DCCD, caused the breakdown of the mechanism that regulates the intracellular pH. H -ATPase appears to have an important part in the regulation of the intracellular pH.

1984-12-01

236

Contrasting Kondo behavior and resonant inverse photoemission spectra of CeTSi{sub 3} and CeTGe{sub 3} (T=Rh and Ir)  

Energy Technology Data Exchange (ETDEWEB)

We have investigated CeTSi{sub 3} and CeTGe{sub 3} (T = Rh and Ir) by measuring the magnetic susceptibility, specific heat, electrical resistivity, the resonant inverse photoemission (RIPES) and M{sub IV,V} x-ray absorption spectra (XAS). The germanides showed a very weak Kondo effect, but the silicides exhibited a negatively large Weiss temperature (approx. = -130 K) and a lnT dependence of magnetic resistivity above 100 K, suggesting that they are a Kondo-lattice compound with a high Kondo temperature T{sub K} (approx. = 100 K). The Curie-Weiss law suggests that Ce atoms in these compounds remain close to 3+ down to about 150 K in spite of their high T{sub K}. In general, both RIPES and M{sub IV,V} XAS support their apparently stable valency. (author)

1999-02-28

237

Characterization of proton exchange membrane materials for fuel cells by solid state nuclear magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel model gives the measured S/V ratios in the normal hydration ...

2010-03-15

238

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for ...

2010-10-01

239

A proton nuclear magnetic resonance investigation of the anion Bohr effect of human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution proton nuclear magnetic resonance spectroscopy has been used to investigate the molecular mechanism of the Bohr effect of human normal adult hemoglobin in the presence of two allosteric effectors, i.e., chloride and inorganic phosphate ions. The individual hydrogen ion equilibria of 22-26 histidyl residues of hemoglobin have been measured in anion-free 0.1 M HEPES buffer and in the presence of 0.18 M chloride or 0.1 M inorganic phosphate ions in both deoxy and carbonmonoxy forms. The results indicate that the #beta#2-histidyl residues are strong binding sites for chloride and inorganic phosphate ions in hemoglobin. The affinity of the #beta#2-histidyl residues for these anions is larger in the deoxy than in the carbonmonoxy form. Nevertheless, the contribution of these histidyl residues to the anion Bohr effect is small due to their low pK value in deoxyhemoglobin in anion-free solvents. The interactions of chloride and ...

240

Superconductivity on the threshold of magnetism in CePd{sub 2}Si{sub 2} and CeIn{sub 3}  

Energy Technology Data Exchange (ETDEWEB)

The magnetic ordering temperature of some rare-earth-based heavy-fermion compounds is strongly pressure dependent and can be completely suppressed at a critical pressure, p{sub c}, making way for novel correlated electron states close to this quantum critical point. We have studied the clean heavy-fermion antiferromagnets CePd{sub 2}Si{sub 2} and CeIn{sub 3} in a series of resistivity measurements at high pressures up to 3.2 GPa and down to temperatures in the mK region. In both materials, superconductivity appears in a small window of a few tenths of a GPa on either side of p{sub c}. We present detailed measurements of the superconducting and magnetic temperature-pressure phase diagram, which indicate that superconductivity in these materials is enhanced, rather than suppressed, by the closeness to magnetic order. (author)

2001-03-26

241

Superconductivity on the threshold of magnetism in CePd_2Si_2 and CeIn_3  

International Nuclear Information System (INIS)

The magnetic ordering temperature of some rare-earth-based heavy-fermion compounds is strongly pressure dependent and can be completely suppressed at a critical pressure, p_c, making way for novel correlated electron states close to this quantum critical point. We have studied the clean heavy-fermion antiferromagnets CePd_2Si_2 and CeIn_3 in a series of resistivity measurements at high pressures up to 3.2 GPa and down to temperatures in the mK region. In both materials, superconductivity appears in a small window of a few tenths of a GPa on either side of p_c. We present detailed measurements of the superconducting and magnetic temperature-pressure phase diagram, which indicate that superconductivity in these materials is enhanced, rather than suppressed, by the closeness to magnetic order. (author)

2001-03-26

242

Magnetic properties of B and AB-spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Ni, Mg) materials  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of diluted spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) systems have been studied by mean field theory, probability law and high-temperature series expansions method in the range 0 {<=} x {<=} 1. The exchange interactions are calculated by the first and second theory, respectively. The magnetic phase diagrams of Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) are calculated by the high-temperature series expansions, combined with the Pade approximants method. The critical exponent associated with the magnetic susceptibility ({gamma}) is deduced.

2010-08-06

243

Magnetic and superconducting phases of CePd{sub 2}Si{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The cross-over from a magnetically ordered to a non-magnetic spin liquid state has been investigated in a series of resistance measurements under hydrostatic pressures of up to 30 kbar and at temperatures down to below 200 mK in the heavy fermion antiferromagnet CePd{sub 2}Si{sub 2}. The electrical resistivity changes dramatically with increasing pressure. Near the critical pressure, at which the magnetic ordering temperature is extrapolated to zero, it exhibits a quasi-linear variation over two orders of magnitude in temperature. This non-Fermi liquid form of {rho}(T) extends down to the onset of a new superconducting transition below 430 mK. (orig.).

1996-07-01

244

Magnetic and superconducting phases of CePd_2Si_2  

International Nuclear Information System (INIS)

The cross-over from a magnetically ordered to a non-magnetic spin liquid state has been investigated in a series of resistance measurements under hydrostatic pressures of up to 30 kbar and at temperatures down to below 200 mK in the heavy fermion antiferromagnet CePd_2Si_2. The electrical resistivity changes dramatically with increasing pressure. Near the critical pressure, at which the magnetic ordering temperature is extrapolated to zero, it exhibits a quasi-linear variation over two orders of magnitude in temperature. This non-Fermi liquid form of #rho#(T) extends down to the onset of a new superconducting transition below 430 mK. (orig.).

245

Magnetic Order and Crystal Field Excitations in Er2Ru2O7: A Neutron Scattering Study  

Energy Technology Data Exchange (ETDEWEB)

The magnetic pyrochlore Er{sub 2}Ru{sub 2}O{sub 7} has been studied with neutron scattering and susceptibility measurements down to a base temperature of 270 mK. For the low temperature phase in which the Er sublattice orders, new magnetic Bragg peaks are reported which can be indexed with integer (hkl) for a face centered cubic cell. Inelastic measurements reveal a wealth of crystal field levels of the Er ion and a copious amount of magnetic scattering below 15 meV. The three lowest groups of crystal field levels are at 6.7, 9.1 and 18.5 meV.

2009-10-01

246

A classical model for the magnetic field-induced Wigner crystallization in quantum dots  

Energy Technology Data Exchange (ETDEWEB)

A classical model is presented for magnetic field-induced Wigner crystallization in electron systems confined within two-dimensional quantum dots. In contrast to other classical models, this one does not treat an electron as a point charge; the electron density is assumed to take a Gaussian form corresponding to the lowest Landau level. Using a Monte Carlo method we have determined the equilibrium configurations as functions of the magnetic field. We have found a classical counterpart of the quantum maximum density droplet (MDD) and studied the breakdown of the MDD into a Wigner molecule as well as the transformations of the Wigner molecule shape induced by the external magnetic field. The phase diagram for the classical Wigner molecules has been presented and its qualitative agreement with previous quantum mechanical calculations has been shown.

2004-03-03

247

Spin correlations in the frustrated square lattice Pb{sub 2}VO(PO{sub 4}){sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The new frustrated square-lattice system, Pb{sub 2}VO(PO{sub 4}){sub 2}, has been investigated using polarised neutron scattering. From these studies, made on powdered samples, we have determined the nature of the exchange interactions and the magnetic ordering for this novel quantum magnet. Quantum order from disorder occurs at low temperature, and the ground state observed below the Neel temperature T {sub N}{approx}3.7 K is a collinear antiferromagnet. At room temperature there are no magnetic correlations and it is possible to model the scattering with the V{sup 4+} magnetic form factor. However, at T{approx}20 K, a temperature well into the paramagnetic phase, magnetic correlations are observed, and these spin correlations have been modelled using a high-temperature series expansion. Ferromagnetic nearest-neighbour exchange J {sub 1}{approx}-2 K and ...

2007-03-15

248

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

Energy Technology Data Exchange (ETDEWEB)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a ...

1995-03-01

249

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

International Nuclear Information System (INIS)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a ...

250

Magnetic liquefier for hydrogen  

Energy Technology Data Exchange (ETDEWEB)

This document summarizes work done at the Astronautics Technology Center of the Astronautics Corporation of America (ACA) in Phase 1 of a four phase program leading to the development of a magnetic liquefier for hydrogen. The project involves the design, fabrication, installation, and operation of a hydrogen liquefier providing significantly reduced capital and operating costs, compared to present liquefiers. To achieve this goal, magnetic refrigeration, a recently developed, highly efficient refrigeration technology, will be used for the liquefaction process. Phase 1 project tasks included liquefier conceptual design and analysis, preliminary design of promising configurations, design selection, and detailed design of the selected design. Fabrication drawings and vendor specifications for the selected design were completed during detailed design. The design of a subscale, ...

1992-12-31

251

Low-temperature phase transitions and magnetic susceptibilities of low-dimensional uranium fluorides  

International Nuclear Information System (INIS)

Measurements have been made on the magnetic susceptibilities of the quasi-one-dimensional magnetic #approx#-UF_5 and the cluster magnetic U_2F_9 (a four-nuclear type) over the range 4.2-300 K. The Curie-Weiss law applies for #approx#-UF_5 above 200 K, with #mu#ef = 2.37#mu#B, theta = -148 K; that law also applies to U_2F_9 above 150 K, with #mu#ef = 2.9#mu#B and theta = 118 K. The antiferromagnetic ordering is discussed for the one-dimensional chains in #approx#-UF_5 together with the phase transition observed in U_2F_9 at 6 K. It is assumed that the U"4"+ and U"5"+ valency states are stabilized below the phase-transition point, and only then can U_2F_9 be considered as the compound UF_4 x UF_5.

1987-01-01

252

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

253

Quantum Computing with an Electron Spin Ensemble  

DEFF Research Database (Denmark)

We propose to encode a register of quantum bits in different collective electron spin wave excitations in a solid medium. Coupling to spins is enabled by locating them in the vicinity of a superconducting transmission line cavity, and making use of their strong collective coupling to the quantized radiation field. The transformation between different spin waves is achieved by applying gradient magnetic fields across the sample, while a Cooper pair box, resonant with the cavity field, may be used to carry out one- and two-qubit gate operations.

2009-01-01

254

Preparation and Properties of New Ester-Linked Cleavable Gemini Surfactants  

British Library Electronic Table of Contents (United Kingdom)

We have prepared a series of novel gemini surfactants having ester bonds in their structures. These surfactants possess two identical hydrophilic polyethylene glycol moieties, two hydrophobic alkyl group moieties, and an anionic spacer. The structures of these compounds were confirmed through infrared and nuclear magnetic resonance spectroscopic and elemental analyses. The novel gemini surfactants exhibit excellent surface activity in terms of their surface tension, low-foaming, wetting power, and fluorescence properties. The presence of the ester linkages made these structures cleavable surfactants.

2011-01-01

255

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

256

Molecular accessibility in solvent swelled coal. Quarterly report  

Energy Technology Data Exchange (ETDEWEB)

To expand the information base on molecular accessibility in solvent swelled coal, Argonne Premium Coal Samples (APCS) were swelled in polar, basic solvents before and after moisture loss and upon air oxidation. So far studies have been reported on the changes in pore size distribution as a function of temperature when polar basic swelling solvents are used. Additional studies employing EPR spin probe techniques performed on the breaking up of the hydrogen bonding between bedding planes were later confirmed by magnetic resonance imaging at Argonne National Lab and the University of Illinois.

1992-11-01

257

Magnetic resonance imaging of the pediatric brain  

International Nuclear Information System (INIS)

The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.

258

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

259

IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT  

British Library Electronic Table of Contents (United Kingdom)

Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.

2011-01-01

260

Enriched lithium collection from lithium plasma flow  

International Nuclear Information System (INIS)

In order to understand the physical processes concerned with the selective heating by ion cyclotron resonance and with the subsequent collection of heated particles, experiments were carried out with the extraction of lithium samples, enriched with "6Li isotopes. Probe and integral extractors allow to collect enriched Li at the end of the selective heating region. Surface density distribution on the collector and local isotopic content of lithium are measured, as a function of the screen height and the retarding potential. Dependence of the collected amount of lithium and of its isotopic content on the value of the magnetic field is also measured. 4 figs., 2 tabs., 5 refs.

261

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

262

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

263

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.  

Science.gov (United States)

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737

2006-12-19

264

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed ...

2002-05-01

265

Magnetic properties of laminated perovskite-like ferroelectromagnetics  

International Nuclear Information System (INIS)

Magnetic properties of layer ferromagnets against the thickness are investigated. Two new compounds served for studies: Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1. The Moessbauer effect and the magnetic susceptibility measurements were applied in the experiment. The Faraday method was used in magnetic measurements in fields from 1 to 9,5 kOe. The results of Moessbauer measurements show that temperature dependence of the spectra is typical for compounds with superparamagnetic properties. The magnetic fields Hsub(n) on Fe"5"7 nuclei in Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1 are similar and equal to 520+-10 kOe. Therefore it may be concluded that relaxation times of nuclear spins in these compounds are equal or close to each other. The lines of quadrupole splitting appear in spectra together at 20 K. The results of magnetic ...

1975-01-01

266

Menstrual variation of breast volume and T{sub 2} relaxation times in cyclical mastalgia  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Hormonal activity causes breast volume to change during the menstrual cycle. One possible cause of this volume change is thought to be due to water retention or oedema within the tissues. We used magnetic resonance imaging (MRI) to study the variation in breast volume and {sup 1}H Magnetic Resonance Spectroscopy (MRS) to measure T{sub 2} relaxation times which are known to increase with increasing tissue water content. We hypothesised that an increase in breast volume will elevate T{sub 2} relaxation due to the presence of an increased water content within the breast. T{sub 2} Relaxation time and volume were studied in fifteen control subjects and in a cohort of eight patients with cyclical mastalgia in order to determine whether changes in breast volume and T{sub 2} relaxation times differed in controls and patients during menses, ovulation and premenses. Method: Breast volume was determined ...

2008-02-15

267

"1H and "3"1P nuclear magnetic resonance investigation of the interaction between 2,3-diphosphoglycerate and human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution "1H and "3"1P nuclear magnetic resonance spectroscopy has been used to investigate the binding of 2,3-diphosphoglycerate to human normal adult hemoglobin and the molecular interactions involved in the allosteric effect of the 2,3-diphosphoglycerate molecule on hemoglobin. Individual hydrogen ion NMR titration curves have been obtained for 22-26 histidyl residues of hemoglobin and for each phosphate group of 2,3-diphosphoglycerate with hemoglobin in both the deoxy and carbonmonoxy forms. The results indicate that 2,3-diphosphoglycerate binds to deoxyhemoglobin at the central cavity between the two #beta# chains and the binding involves the #beta#2-histidyl residues. Moreover, the results suggest that the binding site of 2,3-diphosphoglycerate to carbonmonoxyhemoglobin contains the same (or at least some of the same) amino acid residues responsible for binding in the deoxy form. As a result of the specific interactions with ...

268

Twinning mechanism in PrCo_2C_x magnetic phase  

International Nuclear Information System (INIS)

A magnetic rhombohedral PrCo_2C_x (x = 0.05 #approx#0.25) phase (space group Rbar 3m), which is heavily twinned along the #left brace#110#right brace# and #left brace#211#right brace# planes, was identified. The twinning mechanism was explored by analyzing the reduction of crystal symmetry due to the cubic-rhombohedral phase transformation. The origin of the twinning and the formation of four twin variants were attributed to the insertion of carbon interstitials into Co_4 tetrahedrons along the bar 3 axis in the rhombohedral lattice, which corresponds to one of the four equivalent axes of its parent PrCo_2 cubic-lattice.

1997-04-04

269

Comparison of histological findings and parathyroid scintigraphy in hemodialysis patients with secondary hyperparathyroid glands  

International Nuclear Information System (INIS)

The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. ...

2005-04-01

270

Weak ferromagnets with integer and half-integer spin quantum numbers  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigations are presented which demonstrate that the weak ferromagnets are special materials of a larger group of magnets which exhibit two magnetic ordering structures. In weak ferromagnets the main order is antiferromagnetic with a small ferromagnetic component existing in addition. On the other hand, materials in which other combinations of the two basic ordering structures coexist are also known. Common to all these non-collinear spin structures is that the moment components of the two magnetic structures are orthogonal. In the weak ferromagnets this orthogonality manifests already in the paramagnetic phase as a crossover from an isotropic to an anisotropic susceptibility with respect to the applied magnetic field: at high temperatures the antiferromagnetic Curie-Weiss law of the total moment is observed while for T->Tc crossover to a second Curie-Weiss ...

2005-01-31

271

Status of 4-cm-aperture, 17-m-long SSC dipole magnet R D program at BNL  

Energy Technology Data Exchange (ETDEWEB)

Over the last year-and-a-half, several 4-cm-aperture, 17-m-long dipole magnet prototypes were built by Brookhaven National Laboratory (BNL) under contract with the Superconducting Super Collider (SSC) Laboratory. These prototypes are the last phase of a half-decade-long R D program, carried out in collaboration with Fermi National Accelerator Laboratory and Lawrence Berkeley Laboratory, and aimed at demonstrating the feasibility of the SSC main ring dipole magnets. They also prepare the way of the 5-cm-aperture dipole magnet program to be started soon. In this paper, we analyze the mechanical behavior of the BNL prototypes during cool-down and excitation, and we attempt to relate this behavior to the magnet features. The data reveal that the mechanical behavior is sensitive to the vertical collar-yoke interference, and that the magnets exhibited somewhat erratic ...

1991-06-01

272

Imaging magnetic domain structure in sub-500 nm thin film elements  

Energy Technology Data Exchange (ETDEWEB)

Magnetic imaging in the transmission electron microscope (TEM) has been used to examine submicron elements with the aim of discovering down to what element size complex domain patterns can form. The elements were squares, circles, triangles, and pentagons in the size range 100{endash}500 nm and were made from 36 nm Co films or 8 nm Ni{sub 80}Fe{sub 20} (NiFe) with in-plane magnetization. The magnetic domain structures in these elements were imaged at high resolution using the differential phase contrast imaging mode in a TEM. Nonuniform magnetization structures were seen in the images. Vortices were present at remanence in all shapes of 36-nm-thick Co elements down to 100 nm size and in circular NiFe elements down to 116 nm diameter. Triangular NiFe elements did not have a vortex state at remanence, instead the magnetization curved round within the element but ...

2001-06-01

273

Ferroelectric and magnetic properties of Ho{sub 2}CuTiO{sub 6} double perovskite  

Energy Technology Data Exchange (ETDEWEB)

Ho{sub 2}CuTiO{sub 6} double pervoskite is synthesized by solid state reaction method and the phase formation was confirmed by X-ray diffraction. Ho{sub 2}CuTiO{sub 6} crystallizes in space group P63 cm and are isostructural in AMnO{sub 3} structure. We have investigated the effect of the presence of a magnetic ion (Ho{sup 3+}{approx}10.4{mu}{sub B}) in Ho{sub 2}CuTiO{sub 6}, on the magnetic properties, compared to that of an isostructural double perovskite containing Y-ion (non-magnetic), i.e., Y{sub 2}CuTiO{sub 6}. Magnetization measurements on Ho{sub 2}CuTiO{sub 6} showed paramagnetic moment of 0.026{mu}{sub B}/Ho at room temperature in an applied field of 7 T although no saturation is observed at room temperature, whereas, at 5 K, the paramagnetic moment was 0.3{mu}{sub B}/Ho in the same field. Since this compound is non-centrosymmetric, it is of interest to look into the ...

2006-08-15

274

Effect of Ho^3^+ substitutions on the structural and magnetic properties of BaFe12O19 hexaferrites  

British Library Electronic Table of Contents (United Kingdom)

Holmium doped barium based hexaferrites BaFe12-2xHo2xO19 with (x=0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho^3^+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (Ms), remanent magnetization (Mr) and coercivity (Hc) were observed by changing Ho^3^+ content in BaFe12-2xH...

2010-01-01

275

Effect of Ho"3"+ substitutions on the structural and magnetic properties of BaFe_1_2O_1_9 hexaferrites  

International Nuclear Information System (INIS)

Holmium doped barium based hexaferrites BaFe_1_2_-_2_xHo_2_xO_1_9 with (x = 0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho"3"+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (M_s), remanent magnetization (M_r) and coercivity (H_c) were observed by changing Ho"3"+ content in BaFe_1_2_-_2_xHo_2_xO_1_9 ferrites. Coercivity showed a maximum value ...

2010-04-09

276

A novel semidry flue gas desulfurization process with the magnetically fluidized bed reactor.  

Science.gov (United States)

The magnetically fluidized bed (MFB) was used as the reactor in a novel semidry flue gas desulfurization (FGD) process to achieve high desulfurization efficiency. Experiments in a laboratory-scale apparatus were conducted to reveal the effects of approach to adiabatic saturation temperature, Ca/S molar ratio and applied magnetic field intensity on SO(2) removal. Results showed that SO(2) removal efficiency can be obviously enhanced by decreasing approach to adiabatic saturation temperature, increasing Ca/S molar ratio, or increasing applied magnetic field intensity. At a magnetic field intensity of 300Oe and a Ca/S molar ratio of 1.0, the desulfurization efficiency (excluding desulfurization efficiency in the fabric filter) was over 80%, while spent sorbent appeared in the form of dry powder. With the SEM, XRD and EDX research, it can be found that the increase of DC magnetic field ...

2009-03-18

277

Time-varying magnetic fields increase cytosolic free Ca sup 2+ in HL-60 cells  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic fields have been reported to cause a variety of biological effects. It has been hypothesized that many of these phenomena are mediated by a primary effect on the concentration of cytosolic free calcium ((Ca2+)i). We investigated the effects of exposure to electromagnetic fields on (Ca2+)i in HL-60 cells using the Ca2(+)-sensitive fluorescent indicator indo-1. Indo-1-loaded cell samples were exposed to a radiofrequency electromagnetic field, a static magnetic field, and a time-varying magnetic field, which were generated by a magnetic resonance imaging (MRI) unit. We found that a 23-min exposure to all three fields, in combination, induced a significant increase in (Ca2+)i of 31 +/- 8 (SE) nM (P less than 0.01, n = 13) from a basal level of 121 +/- 8 nM. Also, cells exposed to only the time-varying magnetic field had a mean (Ca2+)i that was 34 +/- 10 nM (P less than ...

1990-10-01

278

The electrical measurement of AC losses in a three-phase tri-axial superconducting cable  

International Nuclear Information System (INIS)

In a three-phase tri-axial cable, the magnetic interaction between the phases makes the loss measurement by an electromagnetic method very complex. We developed the theoretical background showing that three-phase AC loss measurements by the electromagnetic method are, in principle, possible. We then implemented this theory in practical measurements on a 3 m long, tri-axial cable fabricated from RABiTS (rolling-assisted biaxially textured substrate) coated conductor. Initially, the proposed measurement technique was implemented in the simpler cases when the three cable phases are 180"0 out of phase, i.e. (0"0, 180"0, 360"0) or (0"0, 360"0, 180"0) rather than (0"0, 120"0, 240"0) as in a traditional three-phase system. For these cases, the currents in the phases are either in phase (360"0 ...

2010-09-01

279

The accurate magnetic structure of CeAl{sub 2} at various temperatures in the ordered state  

Energy Technology Data Exchange (ETDEWEB)

The magnetic structure of the cubic compound CeAl{sub 2} is incommensurate and double-k. The moments on the two Ce sites describe two elliptical helices of opposed chiralities and lie in the (11-bar0) plane, with their Fourier components m{sup k} close to the [111] direction. Recent symmetry considerations, including for the first time the inversion center of the crystal, have reduced the number of parameters of this structure and have underlined the existence of a phase difference between the projections m{sub x}{sup k}, m{sub y}{sup k} and m{sub z}{sup k} of m{sup k}. Up to now, although many neutron investigations have been carried out on CeAl{sub 2} single crystals, no set of magnetic intensities was available which was large and good enough to check whether this phase difference exists or not. We have measured such a set of data, taking great care of the instrumental resolution in order to avoid ...

2008-04-02

280

The accurate magnetic structure of CeAl_2 at various temperatures in the ordered state  

International Nuclear Information System (INIS)

The magnetic structure of the cubic compound CeAl_2 is incommensurate and double-k. The moments on the two Ce sites describe two elliptical helices of opposed chiralities and lie in the (11-bar0) plane, with their Fourier components m"k close to the [111] direction. Recent symmetry considerations, including for the first time the inversion center of the crystal, have reduced the number of parameters of this structure and have underlined the existence of a phase difference between the projections m_x"k, m_y"k and m_z"k of m"k. Up to now, although many neutron investigations have been carried out on CeAl_2 single crystals, no set of magnetic intensities was available which was large and good enough to check whether this phase difference exists or not. We have measured such a set of data, taking great care of the instrumental resolution in order to avoid unwanted contributions to the intensities from other ...

2008-04-02

281

The phase and pole structure of the N{sup *}(1535) in {pi}N{yields}{pi}N and {gamma}N{yields}{pi}N  

Energy Technology Data Exchange (ETDEWEB)

The nature of some baryonic resonances is still an unresolved issue. The case of the N{sup *}(1535) is particularly interesting in this respect due to the nearby {eta} N threshold and interference with the N{sup *}(1650). The N{sup *}(1535) has been described as a threshold effect, as a genuine 3-quark resonance, or as dynamically generated from the interaction of the octet of baryons with the octet of mesons. In the scheme of dynamical generation, predictions for the interaction of the N{sup *}(1535) with the photon can be made. In this study, we simultaneously analyze the role of the N{sup *}(1535) in the {pi}N{yields}{pi}N and {gamma}N{yields}{pi}N reactions and compare to the respective amplitudes from partial-wave analyses. This test is very sensitive to the meson-baryon components of the N{sup *}(1535). (orig.)

2010-01-15

282

Quasienergy description of the driven Jaynes-Cummings model  

CERN Document Server

We analyze the driven resonantly coupled Jaynes-Cummings model in terms of a quasienergy approach by switching to a frame rotating with the external modulation frequency and by using the dressed atom picture. A quasienergy surface in phase space emerges whose level spacing is governed by a rescaled effective Planck constant. Moreover, the well-known multiphoton transitions can be reinterpreted as resonant tunneling transitions from the local maximum of the quasienergy surface. Most importantly, the driving defines a quasienergy well which is nonperturbative in nature. The quantum mechanical quasienergy state localized at its bottom is squeezed. In the Purcell limited regime, the potential well is metastable and the effective local temperature close to its minimum is uniquely determined by the squeezing factor. The activation occurs in this case via dressed spin flip transitions rather than via quantum activation as in other ...

2010-01-01

283

Direct observation of polymerization in the oleic acid-ozone heterogeneous reaction system by photoelectron resonance capture ionization aerosol mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

High molecular weight products of the ozonolysis reaction of particle-phase 9-octadecenoic acid (oleic acid) have been studied by photoelectron resonance capture ionization (PERCI) mass spectrometry (MS). Oleic acid particles ( Formula Not Shown , Formula Not Shown ) were reacted with ozone (1.8x10-4atm) in a flow reactor at reaction times of 8 and 23s. Particles were sampled on-line with a differentially pumped particle inlet and chemically analyzed by PERCI-MS. PERCI is a soft ionization method that permits the direct measurement of relatively high molecular weight compounds, facilitating molecular identification. In addition to cyclic oxygenates, such as secondary ozonides and geminal diperoxides that were reported previously, we demonstrate the formation of polymers at the particle sur...

2006-01-01

284

Detection of free amino acids in proxies of marine aerosol by photoelectron resonance capture ionization aerosol mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Photoelectron resonance capture ionization aerosol mass spectrometry (PERCI-AMS) has been applied to the analysis of proxies for marine aerosols with and without ozone; proxies used were mixed oleic acid-amino acid particles. The mechanism of ion formation for serine (104 m/z), glutamic acid (146 m/z), and phenylalanine (164 m/z) was dissociative electron attachment. This corresponds to loss of the hydrogen atom only, allowing for straightforward identification of the free amino acids. No ozonolysis products for the free amino acids were observed, even at high concentrations of ozone (500 ppm for 19 s). The direct detection of a novel gas-phase hydrated anion, [serine + H2O-H]-, is described. These preliminary results suggest that PERCI-AMS may provide an effective, simple and direct onlin...

2008-01-01

285

An analytical study on excitation of nuclear-coupled thermal hydraulic instability due to seismically induced resonance in BWR  

Energy Technology Data Exchange (ETDEWEB)

A core-wide in-phase neutron flux oscillation, which took place, for example, at LaSalle-2 in the USA in 1988, is one of the nuclear-coupled thermal hydraulic instabilities in boiling water reactors (BWRs). In this study, an analysis has been performed focusing on the excitation of this type of instability in BWRs due to seismically induced resonance, within the scope of a point kinetics model. For this purpose, the TRAC-BF1 code has been modified to take into account the external acceleration in addition to gravity. As a result of this analysis, it is shown that reactivity insertion can occur accompanied by in-surge of the coolant into the core resulting from excitation. It is also shown that the amount of reactivity inserted largely depends on the degree of stability of the initial state and the amplitude of the seismic wave, whose frequency is the same as the characteristic frequency of the instability. (orig.).

1996-04-01

286

An analytical study on excitation of nuclear-coupled thermal hydraulic instability due to seismically induced resonance in BWR  

International Nuclear Information System (INIS)

A core-wide in-phase neutron flux oscillation, which took place, for example, at LaSalle-2 in the USA in 1988, is one of the nuclear-coupled thermal hydraulic instabilities in boiling water reactors (BWRs). In this study, an analysis has been performed focusing on the excitation of this type of instability in BWRs due to seismically induced resonance, within the scope of a point kinetics model. For this purpose, the TRAC-BF1 code has been modified to take into account the external acceleration in addition to gravity. As a result of this analysis, it is shown that reactivity insertion can occur accompanied by in-surge of the coolant into the core resulting from excitation. It is also shown that the amount of reactivity inserted largely depends on the degree of stability of the initial state and the amplitude of the seismic wave, whose frequency is the same as the characteristic frequency of the instability. (orig.).

1996-01-01

287

Treatment of low-frequency pulsating magnetic field on amorphous alloy Fe{sub 78}Si{sub 9}B{sub 13}  

Energy Technology Data Exchange (ETDEWEB)

Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe{sub 78}Si{sub 9}B{sub 13} were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe{sub 78}Si{sub 9}B{sub 13}. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase ...

2007-07-15

288

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

289

Remodeling of the free electron laser with the L-band linac at Osaka University  

International Nuclear Information System (INIS)

The far infrared free electron laser (FEL) has been being developed since 1990 using the L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. The first lasing was obtained in 1994 at wavelengths from 32 to 40 #mu#m. The FEL is now being modified suitable for user experiments. The wiggler with a fixed magnet gap used in the original FEL has been remodeled to make the magnet gap variable. In order to optimize the variable range of the gap, the gain and the diffraction loss were calculated. The peak gain is calculated to be 270% and the diffraction loss to be 22% at 150 #mu#m. The wavelength is expected to be variable from 25 up to at least 150 #mu#m. The two bending magnets in the optical resonator have been remodeled and the vacuum chambers with larger vertical sizes for them have been newly made so that the diffraction loss in these parts becomes smaller than ...

1997-02-28

290

Radio Frequency Plasma Applications for Space Propulsion  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ...

1999-09-13

291

High Voltage Measurements on Nine PFNs for the LHC Injection Kicker Systems  

CERN Document Server

Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions and measurements are ...

2005-01-01

292

R and D on Control Rod Magnetic Suspension Drive Mechanism of CARR  

Energy Technology Data Exchange (ETDEWEB)

This paper deal with the research and develop (R and D) on Control Rod Magnetic Suspension Drive Mechanism (MSDM) of CARR. The MSDM is made up of tube, coil, armature, step motor, lead screw etc. The MSDM use electromagnetics as its main principle. The open solenoid electromagnet technique is employed to implement suspension function. It has advantages of high drive precision, high safety feature, good running reliability, easy maintenance and good economical property. The R and D process of MSDM has three phases including single coil electromagnet, principle prototype and engineering prototype. (author)

2011-07-01

293

Phase separation, transport and magnetic properties of La2/3A1/3Mn1-xCoxO3, A=Ca, Sr (0.5x1)  

British Library Electronic Table of Contents (United Kingdom)

We present the low-temperature physical properties of the polycrystalline perovskite systems La2/3A1/3Mn1-xCoxO3, A=Ca, Sr (0.5x1) including electrical resistance, magnetization, ac and dc susceptibilities. The experimental data suggest the presence of correlated ferromagnetic clusters embedded in some non-ferromagnetic matrix. The systems show semiconducting behavior and negative magnetoresistance.

2008-01-01

294

An investigation into flow regimes for two-phase helium flow  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron accelerator at Fermilab incorporates long two-phase helium passages. During magnet design, the generalized flow map of Baker was used to predict homogeneous flow. Longer than expected magnet time constants led to this investigation. The importance of predicting the flow regime has been amplified with the advent of non-horizontal accelerator designs. A test setup was constructed at Fermilab to investigate two-phase helium flow regimes for conditions practical in accelerator designs. The setup consisted of a standard Tevatron satellite refrigerator, subcooling dewar, heater, 35 m long transfer line, and a specialized end box. A knife blade on the midplane of the transfer line diverted the flow from the upper and lower halves of the pipe to separate vessels in the end box. The amount of liquid above and below the plane was measured at various total mass flow rates and liquid percentages. The ...

1987-10-01

295

Pituitary disease in childhood: utility of magnetic resonance; Patologia hipofisaria en la edad pediatrica: unidad de la resonance magnetica  

Energy Technology Data Exchange (ETDEWEB)

To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children with ...

2000-07-01

296

Magnetic properties of Y_2Cu_2O_5, Y_2BaCuO_5, and Y_2Ba_2O_5 compounds  

International Nuclear Information System (INIS)

The magnetic susceptibility of Y_2Cu_2O_5, Y_2BaCuO_5, and Y_2Ba_2O_5 single-phase compounds in weak magnetic fields (H_0=0.1--20 Oe) and moderate magnetic fields (H_0#=#0.2 Oe it converts into a paramagnetic maximum #chi#(T) which corresponds to an antiferromagnetic transition. In a moderate magnetic field H=500 Oe a normal Curie-Weiss law, #chi##approx##mu#"2_e_f_f (T-#theta#) is observed. At temperatures T=150--300 K, #theta#=38 K and #mu#_e_f_f#approx#2.2 #mu#_B/at. Cu. At T<150 k the temperature dependence of #chi# is described by a simple Curie law with #theta##approx#0. Although the paramagnetic signal is extremely weak, in the Y_2Ba_2O_5 compound the curve of #chi#(T, H_0=100 Oe) for a Y_2ba_2O_5 sample exhibits a slightly smeared maximum at a temperature T#approx#13 K.

1989-01-01

297

On the disrupted magnetic braking model for the period gap of cataclysmic variables  

International Nuclear Information System (INIS)

The disrupted magnetic braking theory for the period gap of cataclysmic variable systems is used to study the binary evolution of low-mass main-sequence-like stars with white dwarf companions. The model is able to reproduce the observed location and width of the gap provided that the average mass transfer rates above the upper edge of the gap are greater than about 1.9 x 10 to the -9th solar masses/yr. For the case of angular momentum loss by magnetic braking, the slope of the mass transfer rate with respect to orbital period is shown to range from 3.4 to 3.7. For the evolutionary sequences considered, the He-3 abundance at the surface of the secondary exceeds 0.0015 after the complete mixing phase, resulting in modifications in the nuclear burning development of nova explosions. 31 refs.

298

Energy saver A-sector power test results  

Energy Technology Data Exchange (ETDEWEB)

The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied by three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.

1982-09-15

299

Electric and magnetic properties of Yb-(Pt, Pd)-(GeSi) intermetallides  

International Nuclear Information System (INIS)

New ternary compounds on the ytterbium base YbPd_2Ge, YbPd_2Si, YbPdGe, YbPdSi, YbPtGe, YbPd_2Ge_2 and known compound YbPdSi_2 were obtained and investigated. Results of measuring the electric resistivity and magnetic susceptibility in the 4.2-300 K range are presented. It is found that YbPdGe, YbPtGe, YbPd_2Ge at low temperatures have magnetic phase transitions, investigations of which testify to dominant contribution of ferromagnetic ordering. The investigation results testify also to substantial effect of ytterbium crystalline environment on the physical properties of compounds under study.

300

Bulk properties and photoelectron spectroscopy of the z-U-Pu phase  

British Library Electronic Table of Contents (United Kingdom)

The z-phase, existing between 35% and 70% U in Pu, belongs to the high-density phases seen from the point of view of systematics of allotropic modifications of Pu metal. Despite the volume per actinide atom only slightly higher than for a-Pu, it magnetic susceptibility is much higher than for a-Pu and exceeds even the d-Pu value. Similarly, the Sommerfeld coefficient g>40mJ/mol Pu K2 exceeds the experimental d-Pu value. The data confirm that the volume is not the primary control parameter affecting the situation around the Fermi level of common Pu phases and they point against the traditional belief that they are essentially narrow 5f band systems. Electronic structure calculations suggest that the 5f states of Pu have slightly lower occupancy comparing with d-Pu. A tendency to the 5f loca...

2011-01-01

302

The role of surfactant in synthesis of magnetic nanocrystalline powder of NiFe2O4 by sol-gel auto-combustion method  

British Library Electronic Table of Contents (United Kingdom)

In this work, a new sol-gel auto-combustion method has been performed to synthesize single phase nickel ferrite nanocrystalline powders by using n-cetyltrimethylammonium bromide, as a cationic surfactant. The gels were prepared from ferric and nickel nitrates and citric acid. Ammonia was used as pH adjusting agent as well. The effects of the surfactant on the after combustion calcination process and the reduction of the resulting powder crystallite size which affects the magnetic properties of the material were investigated by XRD and DTA/TGA techniques. The results showed that the ignition of the gels in air have a self-propagating behavior. Addition of surfactant to the starting solution affected the crystallite size of the synthesized powders and their phase constitution. The crystallit...

2008-01-01

303

The lost heat capacity and entropy in the helical magnet MnSi  

Science.gov (United States)

We report results of measurements and analysis of the heat capacity of MnSi. The measurements included data collection at a magnetic field of 4T, which suppresses strongly the longitudinal spin fluctuations and the phase transition. To analyze the experimental data, calculations of the phonon spectrum and phonon density of states in MnSi were performed. Inelastic neutron scattering with a polycrystalline sample of MnSi was used to validate the computational results. The combination of the experimental and theoretical data turned out to be decisive in revealing some hidden features of the thermal excitations in MnSi. In particular, the analysis of the available data led conclusively to the existence of a negative contribution to the heat capacity and entropy in MnSi at T>Tc, implying that a specific spin ordering process did occur in the paramagnet phase of MnSi.

2011-03-01

304

Collisionless driven reconnection in an open system  

Energy Technology Data Exchange (ETDEWEB)

Particle simulation studies of collisionless driven reconnection in an open system are presented. Collisionless reconnection evolves in two steps in accordance with the formation of two current layers, i.e., an ion current layer in the early ion phase and an electron current layer in the late electron phase. After the electron current layer is formed inside the ion current layer, the system relaxes gradually to a steady state when convergent plasma flow is driven by an external electric field with a narrow input window. On the other hand, when the convergent plasma flow is driven from the wide input window, magnetic reconnection takes place in an intermittent manner, due to the frequent formation of magnetic islands in the vicinity of neutral sheet. (author)

2000-06-01

305

A study on rf plasma nitriding at a constant power in different H_2-N_2 mixtures at different temperatures  

International Nuclear Information System (INIS)

Austenitic stainless steel AISI 304 has been nitrided by radio frequency (rf) plasma containing various nitrogen-hydrogen gas mixtures, in order to study the effect of hydrogen on structure and magnetic properties of the formed compound layer. The thermal temperature has been measured at the vicinity of the samples. The compound layer thus produced has been characterized using, X-ray diffractometer and vibration sample magnetometer. Providing the total pressure of nitrogen and hydrogen is held constant, the addition of hydrogen up to 50% gives new structural phases. The magnetization values of the plasma treated samples are strongly dependent on the percentage of H_2 in the gas phase. An excessive amount of hydrogen (#approx#75%) on the other hand, retards the nitriding process. The surface temperature of the sample and plasma condition is crucial factors for nitriding process.

2006-04-15

306

Physical basis of the effect of hemoglobin on the "3"1P NMR chemical shifts of various phosphoryl compounds  

International Nuclear Information System (INIS)

The marked difference between the intra- and extracellular "3"1P NMR chemical shifts of various phosphoryl compounds when added to a red cell suspension may be largely understood in terms of the effects of hemoglobin on the "3"1P NMR chemical shifts. The presence of [oxy- or (carbonmonoxy)-] hemoglobin inside the red cell causes the bulk magnetic susceptibility of the cell cytoplasm to be significantly less than that of the external solution. This difference is sufficient to account for the difference in the intra- and extracellular chemical shifts of the two phosphate esters trimethyl phosphate and triethyl phosphate. However, in the case of the compounds dimethyl methylphosphonate, diethyl methylphosphonate, and trimethylphosphine oxide as well as the hypophosphite, phenylphosphinate, and diphenylphosphinate ions, hemoglobin exerts an additional, much larger, effect, causing the "3"1P NMR resonances to shift to lower frequency in a manner ...

307

Study of radiation chemistry in solids using solid hydrogen  

Energy Technology Data Exchange (ETDEWEB)

Having simple and highly symmetric structure, solid hydrogen is a useful matrix on the study of radiation-chemical processes in solid phase which have been less understood in previous studies. We have found three outstanding findings: resonance effects on the tunneling reaction H+H{sub 2} {yields} H{sub 2} + H, effects of pressure on the dissociation and recombination of H{sub 2} molecules in solid hydrogen, and high-resolution ESR spectroscopy using a solid parahydrogen matrix. (author)

2002-03-01

308

Nuclear magnetic resonance spectroscopy in the structure elucidation and biosynthesis of natural products  

Energy Technology Data Exchange (ETDEWEB)

Examination of a chloroform extract of Dracaena loureiri Gagnep (Agavaceae), a Thia medicinal plant possessing antibacterial activity, has led to the isolation of fifteen flavenoids. The biogenic relationships among these flavenoids isolated were briefly discussed. Definition of the skeleton and the unambiguous assignment of all of the protons of the isolates was achieved through extensive 2D-homonuclear chemical shift correlation, nuclear Overhauser effect (NOE) difference spectroscopy and 2D-NOE experiments. The {sup 1}H and {sup 13}C NMR spectra of staurosporine, a potent biologically active agent from Streptomyces staurosporeus, were unambiguously assigned by using 2D homonuclear chemical shift correlation, NOE, {sup 1}H-detected heteronuclear multiple-quantum coherence via direct coupling and via multiple-bond coupling for resonance assignments of protonated and nonprotonated carbons, respectively. S. Staurosporeus was found to utilize endogenous and exogenous ...

1988-01-01

309

Free electron laser  

International Nuclear Information System (INIS)

The present article outlines major features of the free electron laser (FEL) and reviews research and development of FEL. Relations among the oscillation frequency, electron beam parameters and wiggler parameters, the physical mechanism of amplification and the physical process of saturation are discussed to identify the difference between FEL and other lasers. The report also outlines techniques for accelerators which are used to generate high-quality, high-energy electron beams required for FEL experiments. Techniques to achieve a short wavelength, high output and high efficiency, and applications of FEL are also discussed. FEL consists of an electron accelerator, wiggler and optical resonator. In FEL, electron beams with a relativistic energy interact resonantly with an electromagnetic field to generate coherent electromagnetic waves. Unlike conventional lasers, FEL does not surfer from restrictions on its oscillation frequency associated ...

310

The effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system  

Energy Technology Data Exchange (ETDEWEB)

The CALPHAD (calculations of phase diagrams) method is used to examine the effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system in the paramagnetic state. The reported susceptibility data for pure Fe is first re-evaluated. The contributions to the total Gibbs energy of the ferrite ({alpha}) and austenite ({gamma}) from the external fields are calculated based on the Curie-Weiss law and the re-evaluated susceptibility data. The Fe-Si phase diagram on the Fe-rich side as a function of applied field is calculated using the Thermo-Calc(TM) package. With increasing field strength, the {gamma} loop shrinks monotonically; that is, the {alpha}/{gamma}-Fe transition temperature increases while that for {gamma}/{delta}-Fe transition decreases, albeit more slowly. Finally, in conformance with the existing CALPHAD databank, Redlich-Kister polynomials are proposed to account ...

2006-07-21

311

Magnetism of the Ni(110) and Ni(100) surfaces: local-spin-density-functional calculations using the thin-slab linearized augmented-plane-wave method  

International Nuclear Information System (INIS)

Results of self-consistent local-spin-density-functional calculations are reported for the first time for the Ni(110) surface, represented by one-, three-, and five-layer slabs. Calculations for one- and five-layer slabs of Ni(100) are also reported. The behavior of the surface magnetization with varying slab thickness elucidates the nature and origin of the surface magnetic moment. We predict a 13% enhancement of the Ni(110) surface magnetic moment compared to the bulk value. For the Ni(100) surface, we find a smaller surface enhancement about 7%, compared to bulk, which agrees with the results of Jepsen et al. The enhancement of surface magnetic moments on Ni(100) and Ni(110) surfaces is attributed to s-d dehybridization at the surface and to the presence of electrostatic shifts required to maintain layer-by-layer charge neutrality. We find that the total d-electron charge is the same in each layer, ...

312

Experimental and theoretical study of periodic intensity bursts in the start-up phase of a free-electron laser oscillator  

International Nuclear Information System (INIS)

In this paper experimental observations and a theoretical analysis of periodic radiation bursts and macropulse formation in the start-up phase of a free-electron laser (FEL) oscillator are presented. This microwave FEL uses a long pulse electron beam with a slowly decaying voltage. The output radiation consists of a superposition of bell-shaped macropulses, each of which is composed of a periodic sequence of short micropulses. The micropulses are separated by a cavity round-trip time. Each bell-shaped macropulse has a random start-up time and amplitude. The startup of the radiation macropulses is correlated with random current spikes on the continuous electron beam. The observed macropulse signal agrees with a theoretical calculation of the impulse response of the FEL oscillator when the shift in the FEL resonance frequency arising from the slow voltage drop of the electron beam is included in the analysis. Possible applications of the ...

313

Value of MRCP using oral Gd-DTPA as negative contrast materials in diagnosis of atypical juxtapapillary duodenal diverticulum  

British Library Electronic Table of Contents (United Kingdom)

Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imaging findings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...

2009-01-01

314

The role of MRI in the diagnosis of recurrent/persistent carpal tunnel syndrome: A radiological and intra-operative correlation  

British Library Electronic Table of Contents (United Kingdom)

MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...

2011-01-01

315

The influence of normal human ageing on automatic movements  

British Library Electronic Table of Contents (United Kingdom)

There is evidence that aged normal subjects have more difficulty in achieving automaticity than young subjects. The underlying central neural mechanism for this phenomenon is unclear. In the present study, functional magnetic resonance imaging (fMRI) was used to investigate the effect of normal ageing on automaticity. Aged healthy subjects were asked to practice self-initiated, self-paced, memorized sequential finger movements with different complexity until they could perform the tasks automatically. Automaticity was evaluated by having subjects perform a secondary task simultaneously with the sequential movements. Although it took more time, most aged subjects eventually performed the tasks automatically at the same level as the young subjects. Functional MRI results showed that, for bot...

2005-01-01

316

Steady particulate flows in a horizontal rotating cylinder  

Energy Technology Data Exchange (ETDEWEB)

Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRI) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio {approximately}7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity field in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit. {copyright} {ital 1998 American Institute of Physics.}

1998-06-01

317

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

318

Primary and multisensory cortical activity is correlated with audiovisual percepts  

British Library Electronic Table of Contents (United Kingdom)

Incongruent auditory and visual stimuli can elicit audiovisual illusions such as the McGurk effect where visual /ka/ and auditory /pa/ fuse into another percept such as/ta/. In the present study, human brain activity was measured with adaptation functional magnetic resonance imaging to investigate which brain areas support such audiovisual illusions. Subjects viewed trains of four movies beginning with three congruent /pa/ stimuli to induce adaptation. The fourth stimulus could be (i) another congruent /pa/, (ii) a congruent /ka/, (iii) an incongruent stimulus that evokes the McGurk effect in susceptible individuals (lips /ka/ voice /pa/), or (iv) the converse combination that does not cause the McGurk effect (lips /pa/ voice/ ka/). This paradigm was predicted to show increased release fro...

2010-01-01

319

Preliminary studies on the chemical characterization and antioxidant properties of acidic polysaccharides from Sargassum fusiforme  

British Library Electronic Table of Contents (United Kingdom)

In order to investigate the antioxidant properties of the polysaccharides from the brown alga Sargassum fusiforme, the crude polysaccharides from S. fusiforme (SFPS) were extracted in hot water, and the lipid peroxidation inhibition assay exhibited that SFPS possessed a potential antioxidant activity. Hence, two purely polymeric fractions, SFPS-1 and SFPS-2 were isolated by the column of DEAE (2-diethylaminoethanol)-Sepharose Fast Flow, with their molecular weights of 51.4 and 30.3 kDa determined by high performance gel permeation chromatography (HPGPC). They were preliminarily characterized using chemical analysis in combination of infrared (IR) and nuclear magnetic resonance (NMR) spectroscopies and found to contain large amounts of uronic acids and ?-glycosidical linkages. The antioxida...

2008-01-01

320

Point defects in dilute nitride III-N-As and III-N-P  

International Nuclear Information System (INIS)

We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.

2006-04-01

321

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the ...

2009-03-01

322

Oxidation of polycaprolactone to induce compatibility with other degradable polyesters  

British Library Electronic Table of Contents (United Kingdom)

Chemical modification of poly(?-caprolactone) PCL by oxidation with potassium permanganate in solution was investigated. According to the data obtained from Fourier transform infrared spectroscopy (FT-IR) and nuclear magnetic resonance 1H NMR, after the oxidation reactions the PCL chains exhibited new functional groups (vinyl and hydroxyl) and possible intermolecular recombination, producing an oxidized-polycaprolactone (PCL-OX). Solution viscometry indicated that degradation also occurred during the oxidation reactions (30% drop in viscosity average molecular weight was detected). Differential scanning calorimetry (DSC) also indicated that PCL was chemically modified and degraded. The successive self-nucleation/annealing (SSA) treatment confirmed that a reduction (or interruption) in line...

2007-01-01

323

Mapping subcortical diffusivity. Application to brain development. Presidential award proceeding  

International Nuclear Information System (INIS)

We studied age-related microstructural changes in the subcortical white matter from adolescence to middle age in 16 healthy male subjects (age range: 12 to 47 years) using diffusion-weighted magnetic resonance (MR) imaging (DWI). Mean diffusivity (MD) of subcortical white matter was mapped onto the overlying cortical surface using our original method. The mean MD values within 76 cortical regions were measured using atlas-based gray matter segmentation and then correlated with age. A significant negative correlation with age was observed in subcortical MD values in several cortical regions, primarily over the bilateral temporal and occipital lobes. Our results demonstrated subcortical microstructural change in postadolescence that may reflect continuing myelination. (author)

2007-01-01

324

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

325

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

326

Influence of attention focus on neural activity in the human spinal cord during thermal sensory stimulation  

British Library Electronic Table of Contents (United Kingdom)

Perceptions of sensation and pain in healthy people are believed to be the net result of sensory input and descending modulation from brainstem and cortical regions depending on emotional and cognitive factors. Here, the influence of attention on neural activity in the spinal cord during thermal sensory stimulation of the hand was investigated with functional magnetic resonance imaging by systematically varying the participants' attention focus across and within repeated studies. Attention states included (1) attention to the stimulus by rating the sensation and (2) attention away from the stimulus by performing various mental tasks of watching a movie and identifying characters, detecting the direction of coherently moving dots within a randomly moving visual field and answering mentally-...

2011-01-01

327

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. MRI ...

2006-06-01

328

Fetal MRI of pathological brain development  

International Nuclear Information System (INIS)

Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)

2006-02-01

329

Experimental parameterization of an energy function for the simulation of unfolded proteins  

DEFF Research Database (Denmark)

The determination of conformational preferences in unfolded and disordered proteins is an important challenge in structural biology. We here describe an algorithm to optimize energy functions for the simulation of unfolded proteins. The procedure is based on the maximum likelihood principle and employs a fast and efficient gradient descent method to find the set of parameters of the energy function that best explain the experimental data. We first validate the method by using synthetic reference data, and subsequently apply the algorithms to data from nuclear magnetic resonance spin-labeling experiments on the Delta 131 Delta fragment of Staphylococcal nuclease. A significant strength of the procedure that we present is that it directly uses experimental data to optimize the energy parameters, without relying on the availability of high resolution structures. The procedure is fully general and can be applied to a range of experimental data and ...

2008-01-01

330

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

331

Episodic Future Thinking Reduces Reward Delay Discounting through an Enhancement of Prefrontal-Mediotemporal Interactions  

British Library Electronic Table of Contents (United Kingdom)

Summary Humans discount the value of future rewards over time. Here we show using functional magnetic resonance imaging (fMRI) and neural coupling analyses that episodic future thinking reduces the rate of delay discounting through a modulation of neural decision-making and episodic future thinking networks. In addition to a standard control condition, real subject-specific episodic event cues were presented during a delay discounting task. Spontaneous episodic imagery during cue processing predicted how much subjects changed their preferences toward more future-minded choice behavior. Neural valuation signals in the anterior cingulate cortex and functional coupling of this region with hippocampus and amygdala predicted the degree to which future thinking modulated individual preference fu...

2010-01-01

332

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

333

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

334

Early diagnosis of skeletal disorders in childhood and adolescence by MRI; Fruehdiagnose orthopaedischer Erkrankungen des Kindes- und Jugendalters mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)

1998-09-18

335

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

336

Characterization of physically vapor deposited AF2400 thin films  

Energy Technology Data Exchange (ETDEWEB)

Anti-reflective coatings made with Teflon AF2400 had the highest damage thresholds recorded for physical vapor deposited coatings at the Lawrence Livermore National Laboratory damage facility. Physical vapor deposited layers of Teflon AF2400, a perfluorinated amorphous polymer, maintained the bulk optical properties of a high transmittance from 200 nm to 1600 nm, and a low refractive index. In addition, the refractive index can be intentionally reduced by control of two common deposition parameters, deposition rate and substrate temperature. Scanning electron microscopy and nuclear magnetic resonance observations indicated that morphological changes caused the variations in the refractive index rather than compositional changes. The coatings adhered to fused silica and silicon wafers under normal laboratory handling conditions.

1993-11-01

337

Brain tumor in childhood. Hjernesvulst hos barn  

Energy Technology Data Exchange (ETDEWEB)

Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.

1990-05-01

338

Biopolymer system for permeability modification in porous media  

Energy Technology Data Exchange (ETDEWEB)

New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were ...

1995-12-31

339

Biochemical monitoring of black raspberry (Rubus coreanus Miquel) fruits according to maturation stage by ^1H NMR using multiple solvent systems  

British Library Electronic Table of Contents (United Kingdom)

Nuclear magnetic resonance (NMR) techniques coupled with multivariate data analysis were used to conduct monitoring of biochemical changes of black raspberry fruits at different stages of maturation and under various extraction and NMR dissolution solvent conditions: extraction with 50% methanol and D"2O as an NMR dissolution solvent, extraction with 50% methanol and 50% methanol-d"4 as an NMR dissolution solvent, and extraction with 100% ethyl acetate and 100% methanol-d"4 as an NMR dissolution solvent. Partial least-squares discriminant analysis reliably distinguished black raspberry fruits according to the maturation stage, whereby the relative levels of various compounds such as amino acids, organic acids, sugars and phenolic compounds were compared using analysis of variance. Sucrose ...

2011-01-01

340

Structure and magnetic properties of nanostructural strontium ferrite prepared by mechanochemical treatment  

International Nuclear Information System (INIS)

Full text: It was recently-established for hexagonal barium ferrite-industrially important magnetically hard material that refinement of the crystallite dimensions into the nanoscale regime, typically #<=# 10 nm, leads after heat treatment at temperatures 800-1000 deg C to significant coercivity increase of up to 6.5 kOe (#approx#3-4 times) with saturation magnetisation values of 50-55 emu/g (#approx#95% of bulk at room temperature). High-energy mechanochemical processing has been applied to prepare nanostructural (nanocrystalline-amorphous) composites. High resolution electron microscopy studies reveal that the enhancement of the final magnetic properties was due to formation of magnetically noninteracting #approx#l,#mu#m Ba-ferrite particles with 5-10 nm amorphous surface layer - depending on annealing parameters. Similar situation was established also for ball milled strontium ferrite (SrFe_1_2O_1_9) powders where ...

341

Magnetic and thermal properties of cubic single-crystal PrCu_4Ag  

International Nuclear Information System (INIS)

We succeeded in synthesizing a new cubic intermetallic compound PrCu_4Ag in a fcc structure. Measurements of X-ray diffraction, magnetic susceptibility, magnetization, specific heat, electrical resistivity, thermal expansion, and elastic constants have been performed on single crystals of PrCu_4Ag. A maximum value of #chi#(T) with a corresponding peak in C(T) suggests that an antiferromagnetic phase transition occurs at T_N=2.4 K, where a sudden decrease in #rho#_4_f(T) and a sharp peak in the thermal expansion coefficient #alpha#(T) were observed. Characteristic Curie-type softening was observed in the temperature dependence of the transverse mode for (C_1_1 - C_1_2)/2 and C_4_4 from 70 K down to T_N, which implies that the crystalline electric field (CEF) ground state is the magnetic triplet #GAMMA#_5. The anisotropic properties in M(T,H) and C(T,H) are studied when the external ...

2010-11-01

342

UAl/sub 2/: Fine structure of the f bands  

Energy Technology Data Exchange (ETDEWEB)

The electronic structure of the C15, or cubic-Laves-phase material, UAl/sub 2/ has been calculated using the linearized relativistic augmented-plane-wave method. The anomalous behavior of the electrical resistivity, specific heat, and magnetic susceptibility can be explained by the fine structure of the density of states near the Fermi energy alone, without the necessity of the introduction of drastic spin fluctuations or many-body effects.

1985-08-15

343

Relativistic effects on chaos. Loss mechanism of runaway electrons in a tokamak  

Energy Technology Data Exchange (ETDEWEB)

The relativistic motion of an electron is numerically analyzed in a tokamak having macroscopic magnetic turbulence. Stochasticity induced by the relativistic motion overwhelms the phase averaging effect, which provides a tokamak with an effective loss mechanism for the avoidance/suppression of runaway electron generation at a major disruption. On the other hand, electrons in the KAM (Kolmogorov-Arnold-Moser) region will be observed as a runaway snake. (author)

2001-12-01

344

Formation of iron oxides during mechanical activation in water  

International Nuclear Information System (INIS)

It has been shown that mechanical milling of iron in water results in formation of nanocrystalline magnetite Fe3O4 with an average particle size of 0.6 ?m, saturation magnetization of 77 Am2/kg and coercivity of ?150 A/cm. Along with magnetite, an antiferromagnetic Fe-O phase (?10 wt%), which is an aggregate of small iron-oxygen clusters forms.

2007-05-21

345

Structure and magnetic properties of nanocrystalline Fe-Mo alloys prepared by mechanosynthesis  

International Nuclear Information System (INIS)

Nanocrystalline samples of Fe_8_0Mo_2_0 and Fe_5_0Mo_5_0 alloys were prepared by the mechanical milling method. The structure, lattice parameters, and crystallite size were determined by the X-ray diffraction. The magnetic properties of the milled products were determined by the Moessbauer spectroscopy. It was observed that in the case of the Fe_8_0Mo_2_0 alloy a solid solution of Mo in Fe was formed with the lattice parameters of the Fe increasing from 0.28659 nm to 0.29240 nm and the crystallite size decreasing from 250 nm to 20 nm. In the case of the Fe_5_0Mo_5_0 alloy there were no clear changes in values of the lattice parameters of Fe and Mo during the milling process, but the crystallite size decreased from 200 to 15 nm. Moessbauer spectra revealed different magnetic phases in the machanosynthesized Fe_Mo samples. In the case of the Fe_8_0Mo_2_0 alloy, the spectrum for the milled mixture indicated the formation of ...

2001-09-23

346

Evaluation of fetal brain development by magnetic resonance imaging. Subependymal germinal matrix layer and cerebral ventricle  

International Nuclear Information System (INIS)

Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The relation between fetal ages and volume of cerebral ventricle also showed similar pattern. This method will be useful to examine the development of the ...

1999-10-01

347

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that ...

1996-01-01

348

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum control of the radial overlap of the laser/negative ion beam ...

2008-09-01

349

Magnetic properties of Pr_2PdSi_3 single crystals  

International Nuclear Information System (INIS)

Ternary R_2TSi_3 intermetallic compounds (R=Rare Earth, T=Transition Metal) with hexagonal AlB_2-type crystallographic structure are known because of their interesting physical properties. Pr_2PdSi_3 single crystals were grown by a vertical floating zone method. The compound exhibits congruent melting behavior at a liquidus temperature of about 1770 C. Single crystalline samples show a huge anisotropy at low temperatures due to the crystal electric field effect and order antiferromagnetically below the Neel temperature T_N=2.17 K. This value approximately obeys the linear de Gennes scaling for this class of compounds. The [001] orientation was identified as the magnetic easy axis at room temperature. At lower temperature (#approx#20 K) magnetic easy and hard axes interchange with each other. Two additional magnetic phase transitions were observed at temperatures below 1 K.

2010-03-21

350

Density of states model for the lattice transformation in A-15 compounds  

International Nuclear Information System (INIS)

The cubic-tetragonal lattice transformation in A-15 compounds is described by an empirical model in which the density of states function near the Fermi energy is characterized by a two-parametric peak in addition to the constant part. Two types of peak splitting under tetragonal deformation are considered, leading to qualitatively different results about the phase transition. Results are given for the order parameter, the phase stability, the soft elastic modulus, and the paramagnetic spin susceptibility. Comparing with measurements of the magnetic susceptibility of V_3Si single crystals near the phase transition a better agreement is obtained for a twofold degenerate density of states peak than for a threefold degenerate one. (author).

351

Field driven ferromagnetic phase evolution originating from the domain boundaries in antiferromagnetically coupled perpendicular anitsotropy films  

Energy Technology Data Exchange (ETDEWEB)

Strong perpendicular anisotropy systems consisting of Co/Pt multilayer stacks that are antiferromagnetically coupled via thin Ru or NiO layers have been used as model systems to study the competition between local interlayer exchange and long-range dipolar interactions [1,2]. Magnetic Force Microscopy (MFM) studies of such systems reveal complex magnetic configurations with a mix of antiferromagnetic (AF) and ferromagnetic (FM) phases. However, MFM allows detecting surface stray fields only and can interact strongly with the magnetic structure of the sample, thus altering the original domain configuration of interest [3,4]. In the current study they combine magnetometry and state-of-the-art soft X-ray transmission microscopy (MXTM) to investigate the external field driven FM phase evolution originating from the domain boundaries in such antiferromagnetically coupled perpendicular ...

2008-05-01

352

Magnetic properties and magnetic ordering in the rare earth molybdenum(IV) pyrochlores: R_2Mo_2O_7  

International Nuclear Information System (INIS)

The series of cubic pyrochlore structure compounds, R_2Mo_2O_7 (R = Nd-Yb, Y; R not= Eu), were prepared as single phase materials by solid state reaction between R_2O_3 and MoO_2 at 1400 "0C in a CO/CO_2 = 1 buffer gas atmosphere. Lattice constants obtained from X-ray powder data compare well with results from previous studies. Magnetic susceptibility and magnetization data were obtained for all samples between 300 K and 4.2 K (700 K for R = Gd) and a range of applied fields. For R = Nd, Sm, and Gd magnetic ordering is observed at 97 K, 93 K and 83 K respectively which is assigned to ferromagnetism on the Mo(IV) sublattice. The Mo(IV) moment in the ordered state is about 1 #mu#/sub B/. At low temperatures, the Gd(III) and Mo(IV) moments are apparently coupled feromagnetically in Gd_2Mo_2O_7 yet the high temperature susceptibility data seem to indicate a ferrimagnetic (antiparallel) Gd(III)-Mo(IV) ...

1986-01-01

353

Magnetic braking in differentially rotating, relativistic stars  

International Nuclear Information System (INIS)

We study the magnetic braking and viscous damping of differential rotation in incompressible, uniform density stars in general relativity. Differentially rotating stars can support significantly more mass in equilibrium than nonrotating or uniformly rotating stars, according to general relativity. The remnant of a binary neutron star merger or supernova core collapse may produce such a 'hypermassive' neutron star. Although a hypermassive neutron star may be stable on a dynamical time scale, magnetic braking and viscous damping of differential rotation will ultimately alter the equilibrium structure, possibly leading to delayed catastrophic collapse. Here we treat the slow-rotation, weak-magnetic field limit in which E_r_o_t<magnetic energy, and W is the gravitational binding energy of the star. We assume the system ...

2004-02-15

355

High-temperature ferromagnetism in laser-deposited layers of silicon and germanium doped with manganese or iron impurities  

Energy Technology Data Exchange (ETDEWEB)

The paper reports on the results of a study of the synthesis conditions effects on magnetic and transport properties of nanosized layers of high-T{sub c} diluted magnetic semiconductors (DMS), such as Ge:Mn, Si:Mn and Si:Fe, fabricated by laser-plasma deposition over a wide range of the growth temperature, T{sub g}=(20-550) deg. C on single-crystal GaAs or Al{sub 2}O{sub 3} substrates. Ferromagnetism of the layers was detected by measurement data of the magneto-optical Kerr effect, anomalous Hall effect, negative magnetoresistance and ferromagnetic resonance (FMR) at 5-500 K. The optimum growth temperature, T{sub g}, for Si:Mn/GaAs layers with T{sub c}{approx}400 K is shown to be about 400 deg. C. The Si:Mn/Al{sub 2}O{sub 3} layers with 35% of Mn have the metal-type of conductivity with manifestation of magnetization up to room temperature. Different types of uniformly doped structures and digital ...

2009-04-15

358

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal ...

1999-10-01

359

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...

2003-03-01

360

Quantum molecular dynamics and molecular interactions studied by NMR and INS[Nuclear magnetic resonance; Proton tunnelling; Hydrogen bond  

Energy Technology Data Exchange (ETDEWEB)

The wavefunction of a particle extends into the classically forbidden barrier region of the potential energy surface. The consequence of this partial delocalisation is the phenomenon of quantum tunnelling, an effect which enables a particle to penetrate a potential barrier of magnitude greater than the energy of the particle. The tunnelling probability is an exponential function of the particle mass. The effect is therefore an important contribution to the behaviour of light atoms, in particular the proton. The hydrogen bond has long been appreciated to be an essential component of many biological and chemical systems, and the proton transfer reaction in the hydrogen bond is fundamental to many of these processes. The proton behaviour in the hydrogen bonds of benzoic acid, acetylacetone and calix-4-arene has been studied. A variety of techniques, both experimental and computational, were adopted for the study of the three hydrogen bonded systems. The complementary spectroscopic ...

2002-07-01

361

Nuclear magnetic resonance spectroscopy in biomedicine. Course organized by the Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), September 18-23, 1995; Spettroscopia di risonanza magnetica nucleare in biomedicina. Corso organizzato dall`Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), 18-23 settembre 1995  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di condizioni imposto dalla ...

1997-12-01

362

Magnetic resonance imaging assessment of brain maturation in preterm neonates with punctate white matter lesions  

International Nuclear Information System (INIS)

Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with 22 matched controls with a normal MR appearance. The two groups ...

2007-02-01

363

Magnetic Resonance Perfusion Imaging in Malformations of Cortical Development  

International Nuclear Information System (INIS)

Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side (rCBVRTSC and TTFMTSC) as well as those of the polymicrogyria/contralateral side ...

2007-10-01

364

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with transient ischemic attacks (TIA) and the ...

1997-05-01

365

Hilar cholangiocarcinoma: MR correlation with surgical and histological findings  

International Nuclear Information System (INIS)

Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the ...

2010-10-01

366

Functional magnetic resonance imaging of the normal and abnormal visual system in early life.  

DEFF Research Database (Denmark)

Functional magnetic resonance imaging (fMRI) in young children may provide information about the development of the visual cortex, and may have predictive value for later visual performance. The purpose of this study was to evaluate the usefulness of fMRI for examining cerebral processing of vision in very young infants and in infants with brain damage. We examined 15 preterm infants, 12 children suspected of having a cerebral visual impairment and 10 children with a normal visual system, all of whom were either spontaneously asleep or sedated with chloral hydrate. Cortical response to stroboscopic light stimulation could be demonstrated in all technically acceptable data sets from children with a post-menstrual age (PMA) of > 41 weeks, but not in younger infants. Children < 60 weeks PMA showed either a blood oxygenation level-dependent (BOLD) signal increase or decrease, while all older children showed a signal decrease. The activated ...

2000-01-01

367

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have ...

2008-04-15

368

Detection of Cholangiocarcinoma with Magnetic Resonance Spectroscopy of Bile in Patients with and without Primary Sclerosing Cholangitis  

International Nuclear Information System (INIS)

Background: Early detection of cholangiocarcinoma (CC) is very difficult, especially in patients with primary sclerosing cholangitis (PSC) who are at increased risk of developing CC. Purpose: To evaluate "1H magnetic resonance spectroscopy ("1H-MRS) of bile as a diagnostic marker for CC in patients with and without PSC. Material and Methods: The institutional review board approved the study, and all patients gave informed consent. Bile from 49 patients was sampled and investigated using "1H-MRS. MR spectra of bile samples from 45 patients (18 female; age range 22-87 years, mean age 57 years) were analyzed both conventionally and using computerized multivariate analysis. Sixteen of the patients had CC, 18 had PSC, and 11 had other benign findings. Results: The spectra of bile from CC patients differed from the benign group in the levels of phosphatidylcholine, bile acids, lipid, and cholesterol. It was possible to distinguish CC from benign ...

2008-10-01

369

Characterization of Absolute-Resonant Eddy Current Probes,  

Science.gov (United States)

... Accession Number : ADD335809. Title : Characterization of Absolute-Resonant Eddy Current Probes,. Corporate Author : ...

370

Studies of weak hcp "3He-"4He solution decomposition and magnetic properties of decomposed samples  

International Nuclear Information System (INIS)

The information is reported on the kinetics of decomposition of weak hcp "3He-"4He solutions with the starting "3He concentration 0.5#+-#0.1% and 1.20#+-#0.2% under the sample pressure 3.5 to 3.8 MPa before the decomposition. The NMR technique of the prompt control of the phase separation process is developed. To accelerate the metastable phase decomposition, the samples were thermally cycled at temperatures below 100 mK. Using the pulse NMR method, the magnetic susceptibility of "3He nuclei and the spin-lattice T_1 and spin-spin T_2 relaxation times were measured on three samples of the decomposed solid solutions with the starting "3He concentration 0.5% at the pressures 3.53, 3.71 and 3.78 MPa. Above 10 mK the Curie-Weiss constant was two to three times higher than the values typical of bulk bcc "3He of the corresponding density. Below 10 mK the magnetic susceptibility was observed to deviate from the ...

371

Magnetic and transport properties of Ba_2Co_9O_1_4 and Ba_1_._9A_0_._1Co_9O_1_4 (A=La or Na)  

International Nuclear Information System (INIS)

The valence and spin-state distributions of Co ions and the complex structure of antiferromagnetic Ba_2Co_9O_1_4 have led to the suggestion that doped Ba_2Co_9O_1_4 compounds may be good thermoelectric materials. We have checked this suggestion by measuring the magnetic properties as well as the transport properties of nominal Ba_1_._9A_0_._1Co_9O_1_4 (A=La or Na). We show that although all compounds are indicated to be single phase by powder X-ray diffraction analysis, they are all p-type polaronic conductors with low mobile-hole concentrations. Magnetic-susceptibility data of the parent and La-doped compounds give evidence of a second magnetic phase with ferromagnetic order setting in below 215 K; but this second phase is not seen in the Na-doped sample. We conclude that the structure is stabilized by oxidation and that cation exolution from the Ba_2Co_9O_1_4 ...

2010-11-01

372

Low energy photoelectron resonance capture ionization aerosol mass spectrometry of small peptides with cysteine residues: Cys-Gly, g-Glu-Cys, and glutathione (g-Glu-Cys-Gly)  

British Library Electronic Table of Contents (United Kingdom)

The photoelectron resonance capture ionization (PERCI) of cysteine (Cys) and small gas-phase neutral peptides that contain the Cys residue (Cys-Gly, g-Glu-Cys, and glutathione (g-Glu-Cys-Gly)) is reported. At an ionization energy less than 1eV two types of dissociative electron attachment ionization were observed for Cys: hydrogen atom loss, resulting in formation of the ion [Cys-H]-, and dissociation of the CH2-SH bond, resulting in formation of the ion [SH]-. The presence of these ions suggests that both the p*(-CO2H) and *(C-S) orbitals can act as low energy electrophores on Cys. This ionization trend was observed for the dipeptides Cys-Gly and g-Glu-Cys as well as glutathione, with evidence that dissociation of the CH2-SH bond in these peptides can also result in ions of the form [M-SH...

2009-01-01

373

Analysis of S-adenosylmethionine and related sulfur metabolites in bacterial isolates of Pseudomonas aeruginosa (BAA-47) by liquid chromatography/electrospray ionization coupled to a hybrid linear quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

A comprehensive and highly selective method for detecting in bacterial supernatants a modified sulfur nucleoside, S-adenosyl-L-methionine (SAM), and its metabolites, i.e., S-adenosylhomocysteine (SAH), adenosine (Ado), 5prime-deoxy-5prime-methylthioadenosine (MTA), adenine (Ade), S-adenosyl-methioninamine (dcSAM), homocysteine (Hcy) and methionine (Met), was developed. The method is based on reversed-phase liquid chromatography with positive electrospray ionization (ESI+) coupled to a hybrid linear quadrupole ion trap (LTQ) and 7-T Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). A gradient elution was employed with a binary solvent of 0.05 M ammonium formate at pH 4 and acetonitrile. The assay involves a simultaneous cleanup of cell-free bacterial broths by solid-pha...

2009-01-01

374

Magnetic susceptibility and electrical properties of Ln/sub 2/3+x/TiO/sub 3+y/ (Ln = Ce, Nd) at 77-450/sup 0/K  

Energy Technology Data Exchange (ETDEWEB)

The magnetic susceptibility and electrical resistivity in cerium and neodymium titanate bronzes in Ln/sub 2/3+x/TiO/sub 3+y/ of the perovskite structure were investigated in the temperature range 77-450/sup 0/K. The deviation of the 1/x = f(T) dependence from the Curie-Weiss law, found for a majority of the compositions, was interpreted from the crystal-field effect based on the state of the Ce/sup 3 +/ and Nd/sup 3 +/ cations. For a number of the phases, a transition from metallic conductivity at high temperatures to semiconducting conductivity was detected at temperatures below 200-250/sup 0/K, which agrees well with the conclusion about the temperature dependence of x, related to the subsystem of Ti/sup 3 +/ cations.

1987-01-01

375

Magnetic properties of RPd_2Si ternary compounds with (R = Gd, Tb, Dy, Ho and Er)  

International Nuclear Information System (INIS)

Magnetic properties of polycrystalline samples of RPd_2Si compounds (R = Gd, Tb, Dy, Ho and Er) are presented. The Gd and Tb based compounds are antiferromagnetic with Neel temperatures of 13.5 and 21 K respectively. For both compounds a metamagnetic transition is observed in low field. Moreover, in TbPd_2Si a transition between two different antiferromagnetic phases is observed at 8.5 K. The Dy, Ho and Er based compounds are ferromagnetic with Curie temperatures of 9, 3.5 ad 2.8 K respectively. The observed properties result from indirect exchange interactions and crystal field effects acting on rare earth ions which lie in a very low symmetry site. (author).

376

Magnetic properties of RPd/sub 2/Si ternary compounds with (R = Gd, Tb, Dy, Ho and Er)  

Energy Technology Data Exchange (ETDEWEB)

Magnetic properties of polycrystalline samples of RPd/sub 2/Si compounds (R = Gd, Tb, Dy, Ho and Er) are presented. The Gd and Tb based compounds are antiferromagnetic with Neel temperatures of 13.5 and 21 K respectively. For both compounds a metamagnetic transition is observed in low field. Moreover, in TbPd/sub 2/Si a transition between two different antiferromagnetic phases is observed at 8.5 K. The Dy, Ho and Er based compounds are ferromagnetic with Curie temperatures of 9, 3.5 ad 2.8 K respectively. The observed properties result from indirect exchange interactions and crystal field effects acting on rare earth ions which lie in a very low symmetry site.

1984-01-01

377

Ion temperature anisotropy in high power helium neutral beam fuelling experiments in JET  

Energy Technology Data Exchange (ETDEWEB)

During helium beam fuelling experiments in JET, distinctive anisotropic features have been observed in the velocity distribution function describing both fast and thermal alpha particle populations. During the initial fuelling phase the central helium ion temperature observed perpendicular to the magnetic field is higher than the central electron temperature, while the central helium ion temperature observed parallel to the magnetic field is lower than or equal to the central electron temperature. In order to verify temperature measurements of both perpendicular and parallel lines of sight, other independent methods of deducing the ion temperature are investigated: deuterium ion temperature, deuterium density, comparison with neutron rates and profiles (influence of a possible metastable population of helium). 6 refs., 7 figs.

1994-07-01

378

Electrical and magnetic properties of Er_2(WO_4)_3  

International Nuclear Information System (INIS)

Measurements of the electrical conductivity, dielectric constant and magnetic susceptibility of pellets of erbium tungstate are reported for the temperature range 300 to 1000 K. The known phase transition near 600 K is in evidence in all these measurements. The conductivity data for T>600 K have been analysed in terms of an exponential relation sigma=sigmasub(0)exp(-Esub(g)/2kT), giving sigma_0=8.892x10"2ohm"-"1cm"-"1 and Esub(g)=1.52eV. There is a weak dispersion in the dielectric constant at around 10"4Hz and a rapid increase above 600 K. The high-temperature data for the susceptibility obey a Curie-Weiss law that gives a value of 9.50 Bohr magneton for Er"3"+ ions and a (ferromagnetic) Curie temperature of 160 K. (author).

1975-09-01

379

Antiferromagnetic Kondo lattice: CePdSi_2  

International Nuclear Information System (INIS)

The compounds CePdSi_2, CeIrSi_2 and CeRhSn_2 have been synthesized and studied by X-ray diffraction, electrical resistivity and magnetic susceptibility. The magnetic susceptibility of CePdSi_2 exhibits two peaks at 6.8 K and 2.5 K, respectively, indicating two antiferromagnetic phase transitions, while that of CeIrSi_2 shows a broad maximum at 150 K, characteristic of valence fluctuating Ce-compounds. CeRhSn_2 remains paramagnetic down to 5 K. The resistivity of CeIrSi_2 exhibits a T"2 dependence at low temperatures, indicating a Fermi-liquid ground state, while those of CePdSi_2 and CeRhSn_2 shows the presence of Kondo and crystal field effects. (orig.).

1996-08-19

380

Half-Heusler phase related structural perturbations near stoichiometric composition FeZnSb  

International Nuclear Information System (INIS)

Half-Heusler phases XYZ (Pearson symbol cF12) are chemically versatile and rich in physical properties. The half-Heusler phase in the Fe-Zn-Sb ternary system was reported in the year 2000. In this work, two new ternary phases are identified in the vicinity of the equiatomic composition FeZnSb in the same system: Fe1-xZnSb (tetragonal, space group P4/nmm, Pearson symbol tP6-?, Z=2: a=4.1113(6) A, c=6.0127(12) A for x=0.08 (1), and a=4.1274(6) A, c=6.0068(12) A for x=0.12 (2)); and Fe7.87Zn6.72Sb8 (Fe0.98Zn0.84Sb) (3) (cubic, space group Fm-3m, Pearson symbol cF96-?, Z=4, a=11.690(13) A). 1 and 2 crystallize in the PbFCl-type structure, and 3 adopts a unique 2x2x2 supercell of a normal half-Heusler structure. The structures of both the tetragonal and cubic phases can be described as assemblies of half-Heusler structure related subunits. Electrical resistivity measurement on the pure sample of 2 shows it ...

2011-05-01

381

Effect of Ho{sup 3+} substitutions on the structural and magnetic properties of BaFe{sub 12}O{sub 19} hexaferrites  

Energy Technology Data Exchange (ETDEWEB)

Holmium doped barium based hexaferrites BaFe{sub 12-2x}Ho{sub 2x}O{sub 19} with (x = 0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho{sup 3+} acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (M{sub s}), remanent magnetization (M{sub r}) and coercivity (H{sub c}) were observed by changing Ho{sup 3+} content in BaFe{sub 12-2x}Ho{sub 2x}O{sub 19} ...

2010-04-09

382

Design and operating experience of a 40 MW, highly-stabilized power supply  

Energy Technology Data Exchange (ETDEWEB)

Four 10 MW, highly-stabilized power supply modules have been installed at the National High Magnetic Field Laboratory in Tallahassee, FL, to energize water-cooled, resistive, high-field research magnets. The power supply modules achieve a long term current stability if 10 ppM over a 12 h period with a short term ripple and noise variation of <10 ppM over a time period of one cycle. The power supply modules can operate independently, feeding four separate magnets, or two, three or four modules can operate in parallel. Each power supply module consists of a 12.5 kV vacuum circuit breaker, two three-winding, step-down transformers, a 24-pulse rectifier with interphase reactors, and a passive and an active filter. Two different transformer tap settings allow rated dc supply output voltages of 400 and 500 V. The rated current of a supply module is 17 kA and each supply module has a one-hour overload capability of 20 kA. The ...

1995-07-01

383

High-efficiency Resonant rf Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams  

Energy Technology Data Exchange (ETDEWEB)

High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on adiabatic fast passage. We discuss the design of the spin rotator and describe two types of transmission-based neutron ...

2008-08-01

384

Quantitative analysis of spinal CSF dynamics using magnetic resonance imaging: experimental and clinical studies; MR-tomographische Liquorflussmessungen am Spinalkanal mit einem optimierten MRT-Protokoll: experimentelle und klinische Untersuchungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Measurement of the oscillating CSF flow in the spinal canal (SC) of healthy volunteers and in patients with post-traumatic syringomyelia (PTS) using an optimized MRI protocol as well as to determine whether stenosis induced velocity changes are detectable using MRI. Methods: In 68 healthy volunteers quantitative studies of CSF flow in the cervical, thoracic, and lumbar regions were performed. First, an optimized sequence was developed and tested in 19 volunteers using four different flow-encoding velocities (4, 8, 12, 16 cm/s). Secondly, the optimized sequence was employed in 49 volunteers to measure the different CSF patterns in the cervical, thoracic, and lumbar spinal canals (CSC, TSC, LSC). Part three of the study, in which patients with PTS are being examined is still underway. We measured the maximum velocity (cm/s), the pixel area (mm{sup 2}), and the stroke volume (ml/s). Using a flow model the velocities prior to and after compression with 5 different power levels ...

2001-04-01

385

Study of the $pp \\to np\\pi^+$ reaction at 1.25 GeV with HADES  

CERN Document Server

In pp collisions at 1.25 GeV kinetic energy, the HADES collaboration aimed at investigating the di-electron production related to $\\Delta$ (1232) Dalitz decay ($\\Delta^+ \\to pe^+e^-$). In order to constrain the models predicting the cross section and the production mechanisms of $\\Delta$ resonance, the hadronic channels have been measured and studied in parallel to the leptonic channels. The analyses of $pp\\to np\\pi^+$ and $pp\\to pp\\pi^0$ channels and the comparison to simulations are presented in this contribution, in particular the angular distributions being sensitive to $\\Delta$ production and decay. The accurate acceptance corrections have been performed as well, which could be tested in all the phase space region thanks to the high statistic data. These analyses result in an overall agreement with the one-$\\pi$ exchange model and previous data.

2009-01-01

386

Resonant CP violation in MSSM Higgs production and decay at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We study CP-violating phenomena in the production, mixing and decay of a coupled system of CP-violating neutral Higgs bosons at {gamma}{gamma} colliders, assuming a Minimal Supersymmetric Standard Model (MSSM) Higgs sector in which CP violation is radiatively induced by phases in the soft supersymmetry-breaking gaugino masses and third-generation trilinear squark couplings. We discuss CP asymmetries in the production and decays of {mu}{sup +}{mu}{sup -}, {tau}{sup +}{tau}{sup -}, b-bar b and t-bar t pairs. We find large asymmetries when two (or all three) neutral Higgs bosons are nearly degenerate with mass differences comparable to their decay widths, as happens naturally in the CP-violating MSSM for values of tan{beta}-bar 5 (30) and large (small) charged Higgs-boson masses.

2005-07-04

387

Resonant CP violation in MSSM Higgs production and decay at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study CP-violating phenomena in the production, mixing and decay of a coupled system of CP-violating neutral Higgs bosons at #gamma##gamma# colliders, assuming a Minimal Supersymmetric Standard Model (MSSM) Higgs sector in which CP violation is radiatively induced by phases in the soft supersymmetry-breaking gaugino masses and third-generation trilinear squark couplings. We discuss CP asymmetries in the production and decays of #mu#"+#mu#"-, #tau#"+#tau#"-, b-bar b and t-bar t pairs. We find large asymmetries when two (or all three) neutral Higgs bosons are nearly degenerate with mass differences comparable to their decay widths, as happens naturally in the CP-violating MSSM for values of tan#beta#-bar 5 (30) and large (small) charged Higgs-boson masses.

2005-07-04

388

Isomeric states and spin polarization in A approx. 90 nuclei  

Energy Technology Data Exchange (ETDEWEB)

The observed inhibition of M4 transitions in A approx. 90 nuclei has represented a long standing theoretical problem. In particular by calculating first- and second-order configuration mixing contributions to the inhibited M4 lifetimes of /sup 89/Y and /sup 87/Sr, it is found that the first-order perturbative treatment of the residual interaction usually used in shell-model calculations is unjustified in this case. Using random-phase approximation techniques, the renormalization effects of collective (''giant'') M4 resonances in /sup 88/Sr on the low energy M4 transitions in /sup 89/Y and /sup 87/Sr are investigated. It is concluded that the observed retardation of M4 lifetimes in these nuclei is consistent with the manifestation of nuclear spin polarization.

1980-04-01

389

Coupled two-component atomic gas in an optical lattice  

CERN Document Server

We study the ground state of an ideal coupled two-component gas of ultracold atoms in a one dimensional optical lattice, either bosons or fermions. Due to the internal two-level structure of the atoms, the Brillouin zone is twice as large as imposed by the periodicity of the lattice potential. This is reflected in the Bloch dispersion curves, where the energy bands regularly possess several local minima. As a consequence, when the system parameters are tuned across a resonance condition, a non-zero temperature topological first order phase transition occurs which arises from an interplay between initernal and kinetic atomic energies. It is shown that these phenomena are also captured for two and three dimensional optical lattices.

2008-01-01

390

Automated bead-positioning system for measuring impedances of R-F cavity modes  

Energy Technology Data Exchange (ETDEWEB)

We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.

1993-05-01

391

A fluid structure coupling of the Ariane-5 nozzle section during start phase by detached eddy simulation  

British Library Electronic Table of Contents (United Kingdom)

Concerning the requirements of future rocket technologies, providing a cost-efficient access to orbit as well as an increase in system reliability, a deeper insight into the unsteady phenomena during ascent of modern launchers is essential. Unsteady interactions and resonances of the turbulent separated launcher wake and the nozzle structure play an important role for the design of future main stage propulsion systems. The so-called buffeting coupling phenomenon is one of the main challenges during ascent. In the present study, a coupled simulation of the afterbody of the Ariane-5 launcher with a realistic structural and aerodynamic representation of different nozzle configurations is carried out. On the computational fluid dynamics side, unsteady detached eddy simulations are coupled with...

2011-01-01

392

5 GHz GaAs monolithic astable multivibrator type voltage controlled oscillator  

Science.gov (United States)

A 5 GHz GaAs monolithic astable multivibrator-type voltage-controlled oscillator has been developed. The monolithic oscillator uses 2 micron long self-aligned TiW-silicide gate MESFETs as well as GaAs Schottky diodes for capacitance. Good agreement between the experiment and calculations for oscillation frequency characteristics versus control voltage is obtained by assuming donor density in the FET active layer to be a Gaussian distribution. This oscillator is useful for monolithic front ends and phase-locked oscillators used in microwave signal processing. X-band oscillation frequency can be obtained with 1 micron long gate FET and low loss resonance inductors.

1984-03-01

393

Transformation of the ATOMKI-ECRIS into a Plasma Device  

International Nuclear Information System (INIS)

Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check the components and charge-state of the plasma. A new, large, but ...

2006-01-01

394

Physical properties of high-temperature superconductors  

International Nuclear Information System (INIS)

The authors have measured the magnetization of single-phase 90-K superconductors, GdBa_2Cu_3O/sub 6+#delta#/, EuBa_2Cu_3O/sub 6+#delta#/, and SmBa_2Cu_3O/sub 6+#delta#/ with a SQUID magnetometer. They have shown that, in the superconducting state, each magnetization-field curve exhibits a maximum at #approx# 100 G, followed by a linear increase of the magnetization with a slope only approximately one-fifth of the slope for a field smaller than 50 G. They have also investigated the effect of #gamma#-irradiation on YBa_2Cu_3O/sub 6+#delta#/, SmBa_2Cu_3O/sub 6+#delta#/, and have found that the radiation damage results in the appearance of a tail in the superconducting transition. They have also shown that the normal resistance decreases with increasing radiation exposure up to a dose of 10 Mrad.

395

Neutron scattering studies of mixed-valence semiconductors  

Energy Technology Data Exchange (ETDEWEB)

Neutron scattering experiments on the mixed-valence (MV) compounds SmB{sub 6} are reported. The inelastic magnetic response of SmB{sub 6} at T = 2 K, measured on a double-isotope single crystal,displays a strongly damped peak at 35 meV corresponding to the inter multiplet transition of Sm{sup 2+}. At lower energies ( h.{omega} {approx_equal} 14 meV), a narrow magnetic excitation is observed, with remarkable scattering-vector and temperature dependences of its intensity. This novel feature is discussed in terms of recent theoretical works describing the formation of an anisotropic local bound state in semiconducting MV materials. If the average samarium valence is decreased by substituting La for Sm, a peak is found to appear at high energies. The elastic magnetic form factor of SmB{sub 6} was determined using polarised neutrons and no significant difference is observed in its Q-dependence with respect to that of pure ...

1994-12-31

396

Magnetic and superconducting quantum critical points of heavy-fermion systems  

Energy Technology Data Exchange (ETDEWEB)

Two examples of heavy-fermion systems are presented : CePd{sub 2}Si{sub 2}, an antiferromagnet with a quantum critical point at P{sub C}=28 kbar and UGe{sub 2} an itinerant ferromagnet which transits in a paramagnetic phase above P{sub C}=16 kbar. In CePd{sub 2}Si{sub 2} the superconductivity domain is centered on P{sub C}. Special attention was given to the superconducting and magnetic anomalies at their superconducting and Neel temperatures. In UGe{sub 2} superconductivity appears in 9 kbar at a temperature T{sub S}, more than two orders of magnitude lower than the Curie temperature; furthermore, it occurs only on the magnetic border (P<P{sub C}). Another characteristic temperature T{sub X} is detected by resistivity; the zigzag uranium chain of the lattice may favor a supplementary nesting in the majority spin band.

2001-05-01

397

High field ESR of P-doped Si for Quantum Computing Application  

Energy Technology Data Exchange (ETDEWEB)

We measured ESR of phosphorous-doped silicon with a low concentration of P, n, at high magnetic fields and low temperatures to investigate the states of nuclear spin. A sample with n = 6.52 x 10{sup 16} /cm{sup 3} was studied at 2.85 T (80 GHz) from 30 K to 2.3 K by field-modulating cw-ESR for a fixed 0 dB power. As the temperature was lowered, the out-of-phase signal appeared around 18 K, reached at a maximum intensity at 13 K, and disappeared around 6 K. The out-of-phase signal is referred to the field modulation. The in-phase signal started to change from the derivative of absorption spectrum at high temperatures to absorption-like shape around 15 K and asymmetry of intensity for two peaks of hyperfine-separated signals increased as temperatures was lowered. Below 10 K, the saturation of the in-phase signal started to appear. We speculate that the asymmetry is caused by ...

2009-02-01

398

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

399

Role of core toroidal rotation on the H-mode radial electric field shear, turbulence, and confinement as studied by magnetic braking in the DIII-D tokamak  

International Nuclear Information System (INIS)

''Magnetic braking'' of the plasma toroidal rotation in the high confinement H mode by applied resonant, low m,n=1 static error fields is used in DIII-D [Nucl. Fusion 31, 875 (1991)] as an independent control to evaluate the E_rxB stabilization of microturbulence in the plasma core. In the core (#rho# approx-lt 0.9) of a tokamak, the radial electric field and its shear are dominated by toroidal rotation. The fundamental quantity for shear stabilization of microturbulence is shear in the velocity of the fluctuations v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#E_rxB/B#centre dot#B which in the core is v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#v_#phi#B_#theta#/ B_#phi#. With magnetic braking greatly decreasing the toroidal rotation and thus reducing the core radial electric field and shear, far infrared (FIR) measurements of density microturbulence show downshifting in frequency near #rho##approx#0.8 as a result of the reduced Doppler shift ...

400

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.  

DEFF Research Database (Denmark)

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global stimulation, ...

2004-01-01

401

Continuum damping of toroidal Alfven eigenmodes in finite-#beta# tokamak equilibria  

International Nuclear Information System (INIS)

A general theoretical approach for the study of the two-dimensional structure of high-n Toroidal Alfven Eigenmodes (TAE) in finite-#beta#, large aspect ratio (R_o/a much-gt 1) tokamak equilibria is presented. Here, n is the toroidal mode number, #beta# = plasma/magnetic pressure, and a(R_o) is the minor (major) radius of the torus. It is shown how the general pseudo-differential boundary value problem for the radial eigenmode structure can be systematically constructed from the local dispersion relation; which is obtained using the ballooning formalism. The TAE modes are characterized by a broad radial envelope, the width of which is independent on the mode number in the general case of monotonic equilibrium profiles. The results on the two-dimensional eigenmode structure are expected to be applicable to drift-type waves. The ballooning transform is generalized here to handle singular eigenfunctions typical of the continuous shear Alfven spectrum, and, thereby, ...

402

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were ...

2011-09-01

403

Stabilizing effect of the electron-beam self-fields on the phase-space trajectory in a self-amplified spontaneous emission free-electron laser operating in ultraviolet and x-ray spectral ranges  

International Nuclear Information System (INIS)

A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction ...

2004-02-28

404

Planar QED at finite temperature and density: Hall conductivity, Berry's phases and minimal conductivity of graphene  

CERN Document Server

We study 1-loop effects for massless Dirac fields in two spatial dimensions, coupled to homogeneous electromagnetic backgrounds, both at zero and at finite temperature and density. In the case of a purely magnetic field, we analyze the relationship between the invariance of the theory under large gauge transformations, the appearance of Chern-Simons terms and of different Berry's phases. In the case of a purely electric background field, we show that the effective Lagrangian is independent of the chemical potential and of the temperature. More interesting: we show that the minimal conductivity, as predicted by the quantum field theory, is the right multiple of the conductivity quantum and is, thus, consistent with the value measured for graphene, with no extra factor of pi in the denominator.

2009-01-01

405

Test results of TQS03: a LARP shell-based Nb3Sn quadrupole using 108/127 conductor  

Energy Technology Data Exchange (ETDEWEB)

Future insertion quadrupoles with large apertures and high gradients will be required for the Phase II luminosity upgrade (10{sup 35} cm{sup -2}s{sup -1}) of the Large Hadron Collider (LHC). Although improved designs, based on NbTi, are being considered as an intermediate step for the Phase I upgrade, the Nb{sub 3}Sn conductor is presently the best option that meets the ultimate performance goals for both operating field and temperature margin. As part of the development of Nb{sub 3}Sn magnet technology, the LHC Accelerator Research Program (LARP) developed and tested several 1-meter long, 90-mm aperture Nb{sub 3}Sn quadrupoles. The first two series of magnet used OST MJR 54/61 (TQ01 series) and OST RRP 54/61 (TQ02 series) strands. The third series (TQ03) used OST RRP 108/127 conductor. The larger number of sub-elements and the consequent reduction of the effective filament size, together with an ...

2009-09-13

406

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

408

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

409

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

410

Studies of nuclear processes at the Triangle Universities Nuclear Laboratory. Progress report, 1 September 1995--31 August 1996  

Energy Technology Data Exchange (ETDEWEB)

The Triangle Universities Nuclear Laboratory (TUNL)--a collaboration of Duke University, North Carolina State University, and the University of North Carolina at Chapel Hill--has had a very productive year. This report covers parts of the second and third year of a three-year grant between the US Department of Energy and the three collaborating universities. The TUNL research program focuses on the following areas: precision test of parity-invariance violation in resonance neutron scattering at LANSCE/LANL; parity violation measurements using charged-particle resonances in A = 20--40 targets and the A = 4 system at TUNL; chaotic behavior in the nuclei {sup 30}P and {sup 34}Cl from studies of eigenvalue fluctuations in nuclear level schemes; search for anomalies in the level density (pairing phase transition) in 1f-2p shell nuclei using GEANIE at LANSCE/LANL; parity-conserving time-reversal noninvariance tests using {sup ...

1996-09-01

411

Progress in construction of the LHC  

CERN Document Server

The Large Hadron Collider (LHC) project, approved by the CERN Council in December 1994, has now fully entered its construction phase, with the detailed technical definition of the major systems, and the adjudication of a number of large procurement contracts. We first recall the main features and characteristics of the LHC, report on the advances in definition of the layout and optics as well as on preparation of the injector complex, and review recent progress in the key technical systems of the main ring: magnets, cryogenics and vacuum, as well as civil construction, which has started following acceptance by authorities in the Host States.

1998-01-01

412

Physics with Polarized Antiprotons  

Energy Technology Data Exchange (ETDEWEB)

Polarized antiprotons produced by spin filtering with an internal polarized gas target provide access to a wealth of single- and double-spin observables, thereby opening a window to physics uniquely accessible with the HESR at FAIR. This includes a first measurement of the transversity distribution of the valence quarks in the proton, and a first measurement of the moduli and the relative phase of the time-like electric and magnetic form factors G{sub E,M} of the proton. In polarized and unpolarized pp-bar elastic scattering open questions like the contribution from the odd charge-symmetry Landshoff-mechanism at large |t| and spin-effects in the extraction of the forward scattering amplitude at low |t| can be addressed.

2006-04-15

413

A phenomenological Landau theory for electromagnons in cubic spinel multiferroic CoCr_2O_4  

International Nuclear Information System (INIS)

Non-anisotropic free energy is considered which under minimization yields two magnetic phases: a conical spin density wave and a low temperature conical cycloid. Using equations of motion, the excitation spectrum is studied. Knowing the nature of these excitations, the dielectric function as well as the fluctuation specific heat is computed and compared with the experimental spectrum. Due to the electromagnon going soft, the dielectric function (imaginary part) as well as the specific heat capacity show peaks at the temperature where ferroelectricity appears in the system.

2010-06-09

414

Magnetic properties of Ni/sub 100-2x/Mn/sub x/Sb/sub x/-alloys (5less than or equal toxless than or equal to50) - solid and liquid state  

Energy Technology Data Exchange (ETDEWEB)

Magnetothermal measurements up to 1600 K have been made on alloys in the ternary Ni-Mn-Sb system with a constant ratio Mn/Sb=1/1, to which belong the two ferromagnetic Heusler phases Ni/sub 2/MnSb with L2/sub 1/ structure and NiMnSb with C1/sub b/ structure. The susceptibility-temperature curves show the constitution of the vertical section. At high temperatures the susceptibilities obey a Curie-Weiss law. In the solid state the effective magneton number decreases with increasing Mn concentration from 4.9 (Ni/sub 2/MnSb) to 3.8 (NiMnSb). Simultaneously, on the transition from Ni/sub 2/MnSb to NiMnSb there is a strong increase of the susceptibility and of the Curie temperature from 292 to 686 K. In the heterogeneous range between 10 and 20 at.% Mn another phase part appears which is ferromagnetic at room temperature. By a heat treatment it undergoes a distinct development. In the liquid phase, the alloys can be characterized ...

1989-02-01

415

The Mechanical Properties of Alumina Films Formed by Plasma Deposition and by Ion Irradiation of Sapphire  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the correlation between mechanical properties and the density, phase, and hydrogen content of deposited alumina layers, and compares them to those of sapphire and amorphous alumina synthesized through ion-beam irradiation of sapphire. Alumina films were deposited using electron beam evaporation of aluminum and co-bombardment with O{sub 2}{sup +} ions (30-230 eV) from an electron cyclotron resonance (ECR) plasma. The H content and phase were controlled by varying the deposition temperature and the ion energy. Sapphire was amorphized at 84 K by irradiation with Al and O ions (in stoichiometric ratio) to a defect level of 4 dpa in order to form an amorphous layer 370 nm thick. Nanoindentation was performed to determine the elastic modulus, yield strength and hardness of all materials. Sapphire and amorphized sapphire have a higher density and exhibit superior mechanical properties in comparison to the ...

1999-07-16

416

Synthesis, structure and characterisation of the n=4 Aurivillius phase Bi5Ti3CrO15  

International Nuclear Information System (INIS)

The n=4 Aurivillius phase, Bi5Ti3CrO15, was synthesised by solid state reaction. Rietveld analysis of high resolution neutron diffraction data demonstrated this material to adopt the polar space group A21am at room temperature, transforming to the aristotype I4/mmm structure above 650 oC. This phase transition is coincident with an anomaly in DSC signal and relative permittivity, which are characteristic of a ferroelectric-paraelectric phase transition. Bi5Ti3CrO15 exhibits paramagnetic behaviour at low temperature, with short range antiferromagnetic interactions, but no evidence for long range magnetic ordering. This is considered a consequence of significant disorder of Ti and Cr over the available octahedral sites, as demonstrated by analysis of neutron diffraction data. -- Graphical abstract: We report here the synthesis, structure and characterisation of the n=4 Aurivillius ...

2011-02-01

417

Solid-state NMR and XRD study of #alpha#-SiAlON powders prepared by combustion synthesis  

International Nuclear Information System (INIS)

"2"7Al and "2"9Si solid-state NMR spectra and X-ray diffraction (XRD) patterns were obtained for #alpha#-SiAlON powders prepared by combustion synthesis, according to which the phase transformation and structure evolution of #alpha#-SiAlON were studied. It was found that in #alpha#-SiAlON "2"9Si chemical shift values (-48 < #delta# _S_i < -47) were close to those in #beta#-Si_3N_4 and #alpha#-Si_3N_4, indicating that Si atoms kept SiN_4 coordination to a large extent in #alpha#-SiAlON despite the presence of O atoms. Dissimilarly, "2"7Al chemical shift values in #alpha#-SiAlON deviated clearly from that corresponding to AlN_4 coordination (#delta# _A_l #approx# 112) and occurred in a range from #delta# _A_l 95.5 to 99.9, which should be assigned to tetrahedral AlO _xN_4_-_x (0 #<=# x #<=# 4) coordination. The broadening effect of AlO _xN_4_-_x peaks was noticed, which was suggested to induced by slight dispersion of #alpha#-SiAlON compositions. "2"7Al ...

2007-07-31

418

Visualization and volumetric structures from MR images of the brain  

Energy Technology Data Exchange (ETDEWEB)

Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet ...

1994-03-01

419

Thermodynamic and kinetic aspects of surface acidity  

Science.gov (United States)

Our research in the general area of acid catalysis involves the characterization of solid acidity and the corresponding assessment of catalytic performance of acidic materials. Acid characterization studies are required to provide essential information about the type of acid site (i.e., Lewis versus Bronsted), the strength of the sites, and the mobility of molecules adsorbed on the acid sites. An accurate measure of acid strength is given by the heat of adsorption of a basic probe molecule on the acid site. A thermodynamic representation of the mobility of adsorbed species on these sites is given by the entropy of adsorption. Important techniques used in these acid site characterization studies include microcalorimetry, thermogravimetric measurements, temperature programmed desorption, infrared spectroscopy and solid state nuclear magnetic resonance. The combination of these acid site characterization studies with reaction kinetics measurements ...

1992-01-01

420

Surgery for acoustic neurinoma treated by gamma-knife radiosurgery. A case report  

Energy Technology Data Exchange (ETDEWEB)

A 52-year-old woman had a history of left hearing loss for 5 years. An acoustic neurinoma with 3.2 cm in diameter was diagnosed and treated with gamma-knife radiosurgery (19 Gy of marginal dose) 1 year and 4 months ago. She developed headache, nausea, and visual disturbance 1 month prior to admission. Slight left facial palsy appeared after radiosurgery. Magnetic resonance imaging demonstrated the tumor with central necrosis in the left cerebellopontine angle cistern, increasing in size to 3.5 cm in diameter, and hydrocephalus. Tumor removal was performed incompletely, because of the fibrous appearance of the tumor and severe adherence with the surrounding cerebellar tissue. Facial palsy did not worsen after surgery. Since the hydrocephalus was not resolved, a right ventriculo-peritoneal shunt was inserted. The clinical course in this case suggests that tumor removal followed by radiosurgery was an approximately effective treatment for large ...

2001-08-01

421

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li{sub 2}S-SiS{sub 2}-Li{sub 3}PO{sub 4} Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li{sub 2}S{center_dot}0.4SiS{sub 2})centre dotxLi{sub 3}PO{sub 4} oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO{sub n}S{sub 4-n} (n=1,2,3) and PO{sub n}S{sub 4-n} (n=1,2,3) present in the glass samples vanished and the SiS{sub 4}, PS{sub 4}, SiO{sub 4} units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S{sup 2-} increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

422

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li[sub 2]S-SiS[sub 2]-Li[sub 3]PO[sub 4] Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li[sub 2]S[center dot]0.4SiS[sub 2])centre dotxLi[sub 3]PO[sub 4] oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO[sub n]S[sub 4-n] (n=1,2,3) and PO[sub n]S[sub 4-n] (n=1,2,3) present in the glass samples vanished and the SiS[sub 4], PS[sub 4], SiO[sub 4] units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S[sup 2-] increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

423

Sorption equilibrium and hydration studies of lysozyme: water activity and 360-MHz proton NMR measurement  

International Nuclear Information System (INIS)

An attempt to determine lysozyme hydration by employing a proton nuclear magnetic resonance (NMR) spin-echo technique and to correlated such measurements with the 20 "0C sorption equilibrium data is made. Determinations of specific site hydration for lysozyme, as well as proton NMR transverse relaxation rates for five different types of water populations in the lysozyme-water system, are presented over the whole range of lysozyme concentrations. The proton spin-echo NMR results are consistent with a three-component analysis of the sorption isotherm up to 70% water content, above which two additional water populations are identified by 360-MHz proton NMR spin-echoes. On the basis of the proton NMR results, a major component (III) of the lysozyme sorption isotherm is assigned to the water trapped between lysozyem molecules, whose relaxation rate is increased by diffusion barriers. The trapped water population dominates the relationship between ...

424

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After surgical treatment, the ...

425

Sol-gel coatings with phosphonate functionalities for surface modification of magnesium alloys  

International Nuclear Information System (INIS)

Hybrid organic-inorganic coatings with phosphonate functionalities have been synthesized and evaluated as prospective surface treatments for magnesium materials. These coatings have been processed via a sol-gel route by hydrolysis and condensation of a mixture of diethylphosphonatoethyltriethoxy-silane and tetraethoxy-silane with variable molar ratios. The coatings morphology and the surface chemistry at the coating/substrate interface have been characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, "3"1P nuclear magnetic resonance spectroscopy, and time-of-flight secondary ion mass spectrometry. The corrosion protection performance of the coatings deposited on magnesium alloy AZ31B has been examined by a group of electrochemical techniques including potentiodynamic polarization and electrochemical impedance spectroscopy. In addition, a scanning Kelvin probe technique has been used to investigate interfacial ...

2006-08-30

426

Soft tissue manifestations of early rheumatic disease. Imaging with MRI  

International Nuclear Information System (INIS)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a ...

2006-08-01

427

Potential anti fungal agents. Synthesis and activity of 2-alkylthiopyridine-4-carbothioamides  

Energy Technology Data Exchange (ETDEWEB)

A series of 2-alkylthiopyrine-4-carbothioamides were synthesized, and their anti-fungal potency was tested. The chemical structures were proved by infrared spectroscopy (IR) and {sup 1}H nuclear magnetic resonance ({sup 1}H-NMR) data and by elemental analysis. The minimal inhibitory concentration (MIC) and minimal fungicidal concentration (MFC) assessment were used for the estimation of potential activity in vitro. The study comprising 21 clinical isolates of fungi showed that two compounds exhibited fair inhibitory activity against some yeasts and dermatophytes. Selective fungistatic activity against non-dermatophytes (MIC = 3.12-25.0 {mu}g/mL) was found also in another compound. None of the above compounds showed inhibitory activity against non-dermatophyte filamentous fungi. Microbiological activity of 2-alkylthiopyridine-4-carbothioamides appears to be mainly related to hydrophobicity of alkyl in position 2. (authors). 10 refs., 8 tabs.

1996-05-01

428

Novel non-discoid chiral copper(II)-salen type [N2O2] donor Schiff base complexes with a cyclohexane diamine spacer: synthesis, electrochemistry, columnar mesomorphism and DFT study  

British Library Electronic Table of Contents (United Kingdom)

A series of new non-discoid chiral copper(ii)-salen type complexes, [Cu((4-CnH2n+1O)2salen)], n = 14, 16, 18 and salen = N,N'-cyclohexane bis (salicylideneiminato), containing 4-substituted alkoxy tails in the side aromatic rings and a cyclohexane spacer, have been prepared and their mesogenic properties investigated. The compounds were characterised by Fourier transform infra-red spectroscopy, 1H and 13C nuclear magnetic resonance spectroscopy, UV-vis spectroscopy and fast atom bombardment mass spectrometry. Mesomorphic properties of these compounds were studied by polarising optical microscopy, differential scanning calorimetry and X-ray diffraction (XRD). The ligands are non-mesogenic but the complexes exhibited enantiotropic rectangular columnar mesophases (Colr) with extended temperat...

2011-01-01

429

Normal and abnormal water diffusion in the brain  

International Nuclear Information System (INIS)

Diffusion magnetic resonance imaging (MRI) has become an important tool in the radiologic diagnosis of diseases of the brain as it measures molecular motion of water that characterizes the microstructure of tissues. Its most important clinical use to date is the early detection of cerebral ischemia by revealing the ischemic injury shortly after vessel occlusion and simultaneously providing therapy-relevant information on the tissue at risk. Furthermore, diffusion MRI is diagnostically promising in other diseases of the brain and is thus increasingly becoming part of routine clinical protocols in the diagnosis of tumors, inflammation, trauma, demyelination, dysmyelination and neurodegeneration. Although abnormalities of diffusion are generally not pathognomonic, diffusion MRI affords information about tissue changes for specific disorders that complements information obtained with standard MR techniques and frequently shows pathology earlier. In ...

2003-10-01

430

Non-white noise in fMRI: does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2005-01-01

431

Non-white noise in fMRI: Does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2006-01-01

432

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D ...

2008-04-15

433

Mechanism of adenylate kinase. Dose adenosine 5'-triphosphate bind to the adenosine 5'-monophosphate site  

Energy Technology Data Exchange (ETDEWEB)

Although the subtrate binding properties of adenylate kinase (AK) have been studied extensively by various biochemical and biophysical techniques, it remains controversial whether uncomplexed adenosine 5'-triphosphate (ATP) binds to the adenosine 5'-monophosphate (AMP) site of AK. The authors present two sets of experiments which argue against binding of ATP to the AMP site. (a) /sup 31/P nuclear magnetic resonance titration of ATP with AK indicated a 1:1 stoichiometry on the basis of changes in coupling constants and line widths. This ruled out binding of ATP to both sites. (b) ATP and MgATP were found to behave similarly by protecting AK from spontaneous inactivation while AMP showed only a small degree of protection. Such inactivation could also be protected or reversed by dithioerythritol and is most likely due to oxidation of sulfhydryl groups, one of which (cysteine-25) is located near the MgATP site. The results support ...

1987-10-06

434

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der Darstellung der Meningitis beobachtet. Eine ...

1994-12-31

435

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. Contrast MRI study is ...

436

Longitudinal and transverse dynamics of a free electron laser based on a storage ring of second and third generation  

International Nuclear Information System (INIS)

This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a modulation, the FEL can present a periodic or chaotic regime. The ...

437

Light liquid hydrocarbons from the catalytic pyrolysis of sewage sludge lipid  

Energy Technology Data Exchange (ETDEWEB)

The lipid obtained by the toluene extraction of a dried raw Atlanta sewage sludge by the Soxhlet method, was pyrolyzed over activated alumina at atmospheric pressure. A range of weight hourly space velocities (WHSV) from 0.22-1.60/h and a range of temperatures from 400-480[degree]C were selected. A 70 wt % yield of light liquid hydrocarbons was obtained at a WHSV of 0.46/h and 450[degree]C. The sulfur and nitrogen contents of the pyrolysis products were much lower than products from direct liquefaction of sludge. Infrared spectra and [sup 13]C nuclear magnetic resonance confirmed the absence of carbonyl groups in the products. Gas chromatography showed a uniform hydrocarbon chain length distribution across the C[sub 7] to C[sub 17] mass range. The gas product consisted mainly of carbon dioxide and hydrocarbons. Lauric acid was used as a model to study the decarboxylation. The effects of catalyst loading and catalyst moisture content were ...

1993-01-01

438

Kinetic studies of preactivated derivatives of cyclophosphamide by "3"1P NMR spectroscopy  

International Nuclear Information System (INIS)

Selected derivatives of cyclophosphamide (CP) metabolites were synthesized and the solution chemistry of each was studied by "3"1P nuclear magnetic resonance (NMR) spectroscopy under a standard set of reaction conditions at physiological pH (7.4) and temperature (37"0C). Complementary "2H and "1"3C NMR spectral data was obtained using isotopically ("2G and "1"3C) enriched CP metabolites. The CP derivatives were synthesized by the ozonolysis of substituted 3-butenyl phosphorodiamidates, and were isolated as analogues of either cis and trans 4-hydroperoxy-CP or aldophosphamide (AP). The relative ratios of the tautomeric species, 4-hydroxy-CP and AP, and their half-lives (T/sub 1/2/) were measured by "3"1P NMR spectroscopy. The influence of CP metabolites on perfused U-937 cells, a CP-sensitive human lymphoma, was observed by high resolution "3"1P NMR spectroscopy. In this manner, it was possible to measure, for the first time, a rate constant for ...

439

Interaction of cis-diamminediaquoplatinum(II) with adenosylcobalamin and alkylcobalamins  

Energy Technology Data Exchange (ETDEWEB)

The interaction of cis-diamminediaquoplatinum(II) nitrate with adenosylcobalamin and a series of alkylcobalamins was studied by carbon-13 nuclear magnetic resonance spectroscopy and by electronic spectroscopy. With these cobalamins cis-(Pt(NH/sub 3/)/sub 2/(OH/sub 2/)/sub 2/)/sup 2 +/ forms adducts in which N(3) of the 5,6-methylbenzimidazole moiety is co-ordinated to platinum(II) rather than to cobalt(III) of the corrin. The chemical shifts of the 5'-methylene carbon of adenosylcobalamin-platinum adduct and of the Co-methyl carbon of the methylcobalamin-platinum adduct are characteristic of these cobalamins in the base-off form. Furthermore, these cobalamin-platinum complexes have visible spectra identical to those of the cobalamins in acidic solution. The /sup 13/C NMR spectrum of the adenosylcobalamin-platinum complex suggests the presence of a second adduct in which platinum(II) complexes are co-ordinated to both the N(3) of the ...

1980-01-01

440

In vivo phosphorylation of histones H1 and H5 in calf thymus and chicken erythrocytes as studied by /sup 31/P nuclear magnetic resonance spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The /sup 31/P NMR method was first applied to characterize in vivo phosphorylation of H1 and H5 in calf thymus and chicken erythrocytes as well as in vitro phosphorylation of H1 and H5 by cAMP-dependent protein kinase. The amino acid residues phosphorylated in vivo in the histones were exclusively serine residues, and the mole fraction of phosphoserine was estimated to be 0.34 and 0.27 per molecule of calf thymus H1 and chicken erythrocyte H5, respectively. Interestingly, chicken erythrocyte H1 was not phosphorylated in vivo. Three H1 subtypes from calf thymus H1 varied in the /sup 31/P NMR spectra, and the bisected fragments of calf thymus H1 and chicken erythrocyte H5 exhibited characteristic spectral patterns, indicating that there are considerable diversities of the degree of phosphorylation and phosphorylation sites in very-lysine-rich histones. Furthermore, it was found that the microenvironment of phosphoserine residues phosphorylated in vivo in calf thymus H1 and chicken ...

1987-08-01

441

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium ...

1998-06-01

442

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

443

Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis.  

DEFF Research Database (Denmark)

The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly to both the results of the contrast sensitivity test ...

2002-01-01

444

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences  

International Nuclear Information System (INIS)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of ...

445

Effect of external pH on the cytoplasmic and vacuolar pHs in Mung bean root-tip cells  

International Nuclear Information System (INIS)

The effect of the external pH on the intracellular pH in mung bean (Vigna mungo (L.) Hepper) root-tip cells was investigated with the "3"1P nuclear magnetic resonance (NMR) method. The "3"1P NMR spectra showed three peaks caused by cytoplasmic G-6-P, cytoplasmic Psub(i) and vacuolar Psub(i). The cytoplasmic and vacuolar pHs could be determined by comparing the Psub(i) chemical shifts with the titration curve. When the external pH was changed over a range from pH 3 to 10, the cytoplasmic pH showed smaller changes than the vacuolar pH, suggesting that the former is regulated more strictly than the latter. The H"+-ATPase inhibitor, DCCD, caused the breakdown of the mechanism that regulates the intracellular pH. H"+-ATPase appears to have an important part in the regulation of the intracellular pH. (author).

446

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...

447

Diagnostic difficulties in extraosseous Ewing's sarcoma: A proposal for diagnostic criteria  

International Nuclear Information System (INIS)

Five cases diagnosed as extraosseous Ewing's sarcoma (EES) during a 15 year period, and the relevant literature, were reviewed. The diagnosis in these cases was difficult to confirm, mainly because the distinction between the osseous form of Ewing's sarcoma (OES) and either periosteal reactions or direct tumour invasion into adjacent bone by EES was often unclear. The literature suggests that other authors have also encountered difficulties. The authors believe that many cases reported as EES are likely to have been OES. This distinction has some importance, as the two conditions are usually treated in differing ways. The following criteria are proposed for the diagnosis of primary EES: (i) no evidence of bony involvement on magnetic resonance imaging; (ii) no evidence of increased uptake in bone or periosteum adjacent to the tumour on static isotope bone scan images; (iii) a small round cell tumour with no differentiating features on light ...

448

Determination of left ventricular ejection fraction and wall thickness in magnetic resonance imaging at 1.0 Tesla in comparison to echocardiography and biplanar ventriculography  

International Nuclear Information System (INIS)

We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ventriculography (4.5%#+-#10.1). MRI (1.0 T) accurately measures ventricular wall thickness and ejection fraction, ...

449

Crystal growth, structural and optical characterization of a semi-organic single crystal for frequency conversion applications  

International Nuclear Information System (INIS)

Single crystals of semi-organic L-histidine hydrobromide have been grown by slow evaporation technique from a mixture of L-histidine and hydrobromic acid in aqueous solution at ambient temperature. From high-resolution X-ray diffraction analysis, the crystalline perfection of the grown crystal has been studied. Single crystal X-ray diffraction analyses, Nuclear Magnetic Resonance spectral analysis, Thermo-Gravimetry (TG), Differential Thermal Analysis (DTA) and hardness test have been employed to characterize the as-grown crystals. The UV cutoff wavelength of the grown crystal is below 300 nm and has a wide transparency window, which is suitable for second harmonic generation of laser in the blue region. Nonlinear optical characteristics have been studied using Q switched Nd:YAG laser (#lambda#=1064 nm). The second harmonic generation conversion efficiency of the grown crystals confirms their suitability for frequency conversion applications.

2010-12-15

450

Consolidated silica glass from nanoparticles  

International Nuclear Information System (INIS)

A dense silica glass was prepared by consolidating a highly dispersed silicic acid powder (particle size 1H magic-angle spinning (MAS) NMR confirmed an increase in hydroxyl groups in the sample prepared by SPS relative to that of the conventional SiO2 reference glass. Aside from the comparably high water content, we conclude from the similarity of the IR-reflectance and the 29Si MAS NMR spectra of the SPS sample and the corresponding spectra of the conventionally prepared silica glass, that the short- and medium-range order is virtually the same in both materials. Raman spectroscopy, however, suggests that the number of three- and four-membered rings is significantly smaller in the SPS sample compared to the conventionally prepared sample. Based on these results we conclude that it is possible to prepare glasses by compacting amorphous powders by the SPS process. The SPS process may therefore enable the preparation of glasses with compositions inaccessible by conventional methods. - ...

2008-09-01

451

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and cerebello-pontine angle. HRCT best depicts osseous ...

2003-03-01

452

Characterization of systems active in selective catalytic reduction of NO{sub x}  

Energy Technology Data Exchange (ETDEWEB)

This thesis is in the field of gas emission control from automobile and stationary sources. Out of the possible approaches to the elimination of pollutant gases, such as nitrogen oxides (NO{sub x}), one consists in the selective catalytic reduction (SCR) of these NO{sub x} on a suitable heterogeneous catalyst. Ammonia or hydrocarbons are employed as reducing agents. The most important catalysts active in the SCR of NO{sub x} are based on ions of transition metal either supported on several oxides or dispersed in zeolites. The catalysts have been characterized by electron magnetic resonance techniques (EPR, ENDOR, ESEEM) and the interaction of catalysts with nitrogen oxides, with reducing and poisoned agents have been followed with the same techniques. Copper dispersed on alumina and its interaction with both NO and ammonia has been investigated. Also the interaction between both water and ammonia with copper dispersed in zeolite ZSM-5 has been ...

1998-06-01

453

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of PVNS and tendinitis ...

1988-01-01

454

CARM-klystron amplifier for accelerator applications  

International Nuclear Information System (INIS)

We consider the possibility of a cyclotron-autoresonance-maser (CARM) klystron configuration for accelerator applications as an alternative to the gyroklystron amplifier. The potential advantages, compared to gyroklystrons, include: 1) comparable efficiencies at lower values of the electron beam pitch ratio #alpha#, which should improve the beam quality and make the device substantially more stable against the excitation of parasitic mode, 2) operation far from cutoff, which should reduce the fields at cavity walls, allowing higher power operation, and 3) operation at lower magnetic fields for the same cyclotron harmonic number. However, there are two significant issues associated with the design of efficient, high-power CARMs. First, because of the higher value of k_Z, compared to gyroklystrons, CARMs are substantially more sensitive to parallel velocity spread (pitch-angle spread). Second, conventional cavities support a variety of near-cutoff modes, which can ...

2001-05-31

455

Beam-breakup calculations for the Los Alamos free-electron laser (FEL) linac  

International Nuclear Information System (INIS)

In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode acts to deflect the beam, and further assumes that this mode does not couple from one accelerating cavity to the next.

456

Application of spectroscopic techniques for the study of paper documents: A survey  

International Nuclear Information System (INIS)

For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear ...

2009-06-01

457

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...

1998-02-01

458

An availability of brain magnetic resonance imaging (MRI) in the early diagnosis of latent hepatic encephalopathy  

Energy Technology Data Exchange (ETDEWEB)

Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An improvement of this MRI finding was not observed by long-term oral administration of ...

1996-03-01

459

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research ...

2009-03-15

460

A fluorescent aminolipid from a green photosynthetic bacterium  

Energy Technology Data Exchange (ETDEWEB)

A preliminary chemical characterization is presented of phosphate-free aminolipids isolation from Chlorobium limicola f. thiosulfatophilum. The lipid contains no phosphorus, glycerol, sugar, ornithine, or lysine. Ultraviolet absorption and fluorescence spectra indicate that the amino moiety of the lipid is an aromatic heterocyclic compound. Infrared spectra indicate that the lipid is a secondary or tertiary amide, and gas chromatograhic analysis of the hydrolyzed lipid shows that for each 1100 g of lipid, 1 mol of myristic acid (C/sub 14:0/) is linked in an amide bond. Acid hydrolysis of the lipid yields two fluorescent substances, A (ninhydrine positive) and B (negative), in addition to myristic acid. Proton nuclear magnetic resonance (NMR) studies indicate that substance A contains a butyl groups attached to a conjugated ring carbon, two equivalent ethyl groups attached to one or two nitrogen atoms, and two downfield protons (8.4 ppm), ...

1983-04-12

461

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...

2003-05-01

462

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution in the z-axis. ...

2006-04-15

463

Electron cyclotron heating  

International Nuclear Information System (INIS)

Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented ...

464

Resonance Raman enhancement of phenyl ring vibrational modes in phenyl iron complex of myoglobin.  

UK PubMed Central (United Kingdom)

Resonance Raman spectra are reported for the organometallic phenyl-FeIII complexes of horse heart myoglobin. We observed the resonance enhancement of the ring vibrational modes of the bound phenyl group....Full Text Available

1990-04-01

465

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

Energy Technology Data Exchange (ETDEWEB)

Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

466

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

International Nuclear Information System (INIS)

Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

467

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

468

Interference phenomena at the elastic collision of atoms with formation of the Feshbach resonance in the presence of laser radiation field  

British Library Electronic Table of Contents (United Kingdom)

Resonant scattering of atoms with formation of the Feshbach resonance in the presence of a laser radiation coupling the levels of two bound atoms (a molecule) is considered. The laser field leads to a second resonance in scattering and broadening of resonances, which facilitates the possibility of experimental observation of asymmetry of the total scattering cross-section arising because of interference between resonant and potential scatterings. The effects associated with interference of the two channels of decay of a bound system of two atoms (a molecule) in the laser field are studied. An expression is obtained for the scattering length in collision of two cold atoms in the field of laser radiation.

2011-01-01

469

Oxygen stabilization induced enhancement in superconducting characteristics of high-Tc oxides  

International Nuclear Information System (INIS)

In an attempt to enhance the electrical and mechanical properties of the high temperature superconducting oxides, high T(sub c) composites were prepared composed of the 123 compounds and AgO. The presence of extra oxygen due to the decomposition of AgO at high temperature is found to stabilize the superconducting 123 phase. Ag is found to serve as clean flux for grain growth and precipitates as pinning center. Consequently, almost two orders of magnitude enhancement in critical current densities were also observed in these composites. In addition, these composites also show much improvement in workability and shape formation. On the other hand, proper oxygen treatment of Y5Ba6Cu11Oy was found to possibly stabilize superconducting phase with T(sub c) near 250 K. I-V, ac susceptibility, and electrical resistivity measurements indicate the existence of this ultra high T(sub c) phase in this compound. Detailed structure, ...

1991-01-01

470

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

471

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

472

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

473

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

475

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

476

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

478

Inelastic electron scattering, M1 giant resonances and the quest for subnuclear degrees of freedom  

International Nuclear Information System (INIS)

... electrons fine structure giant resonance inelastic scattering iron 54 iron 54

1983-01-17

479

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...

2009-03-01

480

Revisit to the helicity and the generalized self-organization theory  

Energy Technology Data Exchange (ETDEWEB)

It is clarified that the so-caned 'helicity conservation law' is never the conservation equation of the helicity K itself', but is merely 'the time change rate equation of K', which is passively and resultantly determined by the mutually independent volume and surface integral terms. It is shown that since the total helicity K can never be conserved in the real experimental systems, the conjecture of the total helicity invariance is not physically available to real magnetized plasmas in an exact sense. The well-known relaxation theory by Dr. J. B. Taylor is clarified to be neither the variational principle nor the energy principle, but be merely a mathematical calculation, using the variational calculus in order to find the minimum magnetic energy solution from the set of solutions having the same value of K. With the use of auto-correlations for physical quantities, it is presented that a novel ...

2000-09-01

481

Floating zone crystal growth of selected R2PdSi3 ternary silicides  

Energy Technology Data Exchange (ETDEWEB)

Substitution of various rare earths R within the class of R2PdSi3 single crystals with hexagonal AlB2-type crystallographic structure reveals the systematic dependence of anisotropic magnetic properties governed by the interplay of crystal-electric field effects and magnetic two-ion interactions. Here we compare the floating zone (FZ) crystal growth with radiation heating of compounds with R = Tb, Tm, Pr, and Gd. The congruent melting behavior enabled moderate growth velocities of 3 to 5 mmh-1. The preferred growth directions are close to the basal plane of the hexagonal unit cell. The composition of the crystals, except of Tb2PdSi3, is slightly Pd-depleted with respect to the nominal composition 16.7 at.% Pd. Thin precipitates of RSi secondary phases were detected in the crystal matrix. Their phase fraction can be diminished by growth from Pd-rich melt compositions and annealing treatments. The ...

2011-06-01

482

Quasi-ternary nanoparticle superlattices through nanoparticle design  

Energy Technology Data Exchange (ETDEWEB)

Individual nanoscale building blocks exhibit a wide range of size-dependent properties, since their size can be tuned over known characteristic length scales of bulk materials. In the last several years, the possibility of combining different materials in the form of two and three component nanoparticles (NPs) has been extensively explored. Also multi-component materials can be obtained via self-assembly of NPs from their binary colloidal mixtures. These new nanocrystal solids may possess tunable collective properties that originate from interactions between size and composition controlled building blocks. Exchange coupling between neighboring NPs of magnetically soft and hard materials enhances the magnetic energy product of the nanocomposite material. Randomly mixed solids of small and large semiconducting CdSe NPs revealed enhancement of photoluminescence intensity of large semiconductor particles accompanied by quenching of ...

2007-06-19

483

Magnetic resonance imaging of stents. Quantitative in vitro examination at 3 Tesla; Magnetresonanztomographie von Stents. Quantitative MR-Untersuchungen in vitro bei 3 Tesla  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we calculated the apparent vascular lumen within ...

2009-07-01

484

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted images. As for lesions <2 cm, Gd-DTPA ...

1991-01-01

485

Van Der Pol model of a Cerenkov maser  

Energy Technology Data Exchange (ETDEWEB)

A non-linear analysis of a Cerenkov maser is presented. The system consists of a ring configuration of a cylindrical waveguide filled with a dielectric material. A single transverse-magnetic mode is assumed to propagate in the system. A low-density pencil electron beam travels in part of the ring, confined by a strong axial magnetic field. Using the single-particle description for the beam and the wave equation for the field, we obtain a set of two coupled non-linear differential equations describing the slowly varying amplitude and phase of the electromagnetic mode. The gain per path is assumed to be small and the spatial growth of the field is neglected. The resulting time dependent amplitude includes the exponential gain of the linear stage and the saturation to its maximum value. The time dependent frequency is also calculated. The two equations are combined to a single Van Der Pol equation with a non-linear restoring ...

1995-12-31

486

Structure and magnetic properties of polymer matrix nanocomposites  

International Nuclear Information System (INIS)

Structure and magnetic properties of the thermal decomposition products of Fe(III(Co(II) acrylate complex were analysed. The crystalline phases, which were found in the fully processed material, at 643 K, were Fe_3O_4, CoFe_2O_4 and CoO and had a mean particle size of about 30 nm. In the intermediate stages of the thermolysis iron was present in a form of Fe"I"I"I (trivalent low-spin iron), Fe"2"+ (divalent high-spin iron), and Fe_3O_4. The coercivity and remanence were measured versus temperature in the range of 5-300 K, in 1.1 T applied field. Both _MH_c and M_r, decreased showing room temperature values of 0.038 T and 7.49 mT, for coercivity and remanence, respectively. At temperatures below 200 K the hysteresis loops were asymmetrical, opened and shifted towards negative field values. (author)

2001-09-23

487

Structural, electronic and magnetic properties of splat-quenched FeCsub(x) alloys (x<0.05)  

International Nuclear Information System (INIS)

The results of a combined investigation of splat-quenched Fe-Csub(x) (x<0.05) alloys by resistivity, X-ray diffraction and Moessbauer spectroscopy are presented. The residual resistivity increases linearly with the carbon content (#DELTA#rho=5#mu##OMEGA#cm/at.%) with a slope identical to that observed in the dilute ferritic phase. X-ray diffraction reveals the presence of a martensite structure in addition to a small fraction of residual austenite; the dependence of the a and c lattice parameters on xsub(c) agrees with earlier measurements. A detailed investigation of the relative reflexion intensities shows that the as-quenched martensites consist of a mixing of massive martensite and tetragonal martensite for low carbon content and of tetragonal martensite only for xsub(c) approximately 0.05. The Moessbauer spectra reveal 3 or 4 magnetically non equivalent iron sites. From a detailed analysis of the intensity dependence of the subspectra ...

2006-01-01

488

Structural and magnetic properties of barium-gadolinium hexaferrites  

Energy Technology Data Exchange (ETDEWEB)

A series of Gd-substituted M-type barium hexaferrites has been prepared by the ceramic route, according to the formula (Ba{sub 1-x}Gd{sub x})O.5.25Fe{sub 2}O{sub 3} (x=0-0.30). XRD analysis revealed that all the samples present primarily an M-type structure. Samples x=0 and x=0.05 are single-phase. Hematite (Fe{sub 2}O{sub 3}) and GdFeO{sub 3} were detected in the remaining samples. Coercivity (H{sub c}) shows remarkably high values, {approx}293kA/m for x=0.20 and 0.30 with a maximum of 322kA/m for x=0.25. Specific saturation magnetization ({sigma}{sub sat}) of the samples presents a small increase up to x=0.10. The microstructure examination indicates that Gd may act as a grain growth inhibitor.

2007-03-15

489

Structural and magnetic properties of barium-gadolinium hexaferrites  

International Nuclear Information System (INIS)

A series of Gd-substituted M-type barium hexaferrites has been prepared by the ceramic route, according to the formula (Ba_1_-_xGd_x)O.5.25Fe_2O_3 (x=0-0.30). XRD analysis revealed that all the samples present primarily an M-type structure. Samples x=0 and x=0.05 are single-phase. Hematite (Fe_2O_3) and GdFeO_3 were detected in the remaining samples. Coercivity (H_c) shows remarkably high values, #approx#293kA/m for x=0.20 and 0.30 with a maximum of 322kA/m for x=0.25. Specific saturation magnetization (#sigma#_s_a_t) of the samples presents a small increase up to x=0.10. The microstructure examination indicates that Gd may act as a grain growth inhibitor.

2007-03-01

490

Recent trends in heavy-fermion physics  

Energy Technology Data Exchange (ETDEWEB)

We discuss recent results obtained for the heavy-fermion metals UPd{sub 2}Al{sub 3} and YbRh{sub 2}Si{sub 2}. UPd{sub 2}Al{sub 3} is the first among all superconductors for which tunneling and inelastic neutron-scattering data highlight a non-phononic, i.e., magnetic-exciton mediated, pair state. YbRh{sub 2}Si{sub 2} represents a model system exhibiting pronounced non-Fermi liquid effects above a weak antiferromagnetic phase transition at T{sub N}=70 mK. Upon approaching the quantum critical point (T{sub N}{yields}0), by low doping with Ge, one observes for T<0.3 K disparate behavior in the temperature dependences of both the electrical resistivity and the electronic specific heat as well as a Curie-Weiss law in the uniform magnetic susceptibility, implying uncompensated large 4f moments. These observations indicate a break up of the composite quasiparticles into their local f-spin and itinerant conduction-electron ...

2003-05-01

491

New correlated electron physics from new materials  

International Nuclear Information System (INIS)

Many important advances in the physics of strongly correlated electron systems have been driven by the development of new materials: for instance the filled skutterudites MT4X12 (M=alkali metal, alkaline earth, lanthanide, or actinide; T=Fe, Ru, or Os; X=P, As, or Sb), certain lanthanide and actinide intermetallic compounds such as URu2-xRexSi2 and CeTIn5 (T=Co, Rh, or Ir), and layered oxypnictides and related materials. These types of complex multinary d- and f-electron compounds have proven to be a vast reservoir of novel strongly correlated electron ground states and phenomena. In these materials, the occurrence of such a wide range of ground states and phenomena arises from a delicate interplay between competing interactions that can be tuned by partial or complete substitution of one element for another, as well as the application of pressure, and magnetic fields, resulting in rich and complex electronic phase diagrams in the hyperspace of ...

2009-10-15

492

Neutron diffraction study of quasi-one-dimensional spin-chain compounds Ca3Co2-xFexO6  

International Nuclear Information System (INIS)

We report the results of the DC magnetization, neutron powder diffraction and neutron depolarization studies on the spin-chain compounds Ca3Co2-xFexO6 (x = 0, 0.1, 0.2 and 0.4). Rietveld refinement of neutron powder diffraction patterns at room temperature confirms the single-phase formation for all the compounds in rhombohedral structure with space group R3-barc. Rietveld refinement also confirms that Fe was doped at the trigonal prism site, 6a (0, 0, 1/4) of Co. The high temperature magnetic susceptibility obeys the Curie-Weiss law; the value of the paramagnetic Curie temperature (?p) decreases as the concentration of iron increases and it becomes negative for x = 0.4. No extra Bragg peak as well as no observable enhancement in the intensity of the fundamental (nuclear) Bragg peaks has been observed in the neutron diffraction patterns down to 30 K. No depolarization of neutron beam has been observed down to 3 K confirming ...

2008-11-01

493

High Magnetic Field NMR Studies of LiVGe$_2$O$_6$, a quasi 1-D Spin $S = 1$ System  

CERN Document Server

We report $^{7}$Li pulsed NMR measurements in polycrystalline and single crystal samples of the quasi one-dimensional S=1 antiferromagnet LiVGe$_2$O$_6$, whose AF transition temperature is $T_{\\text{N}}\\simeq 24.5$ K. The field ($B_0$) and temperature ($T$) ranges covered were 9-44.5 T and 1.7-300 K respectively. The measurements included NMR spectra, the spin-lattice relaxation rate ($T_1^{-1}$), and the spin-phase relaxation rate ($T_2^{-1}$), often as a function of the orientation of the field relative to the crystal axes. The spectra indicate an AF magnetic structure consistent with that obtained from neutron diffraction measurements, but with the moments aligned parallel to the c-axis. The spectra also provide the $T$-dependence of the AF order parameter and show that the transition is either second order or weakly first order. Both the spectra and the $T_1^{-1}$ data show that $B_0$ has at most a small effect on the alignment of the AF ...

2001-01-01

494

Design of APhF-IH Linac for a Compact Medical Accelerator  

CERN Document Server

The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage ...

2003-01-01

495

Antiferromagnetic Kondo lattice: CePdSi{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The compounds CePdSi{sub 2}, CeIrSi{sub 2} and CeRhSn{sub 2} have been synthesized and studied by X-ray diffraction, electrical resistivity and magnetic susceptibility. The magnetic susceptibility of CePdSi{sub 2} exhibits two peaks at 6.8 K and 2.5 K, respectively, indicating two antiferromagnetic phase transitions, while that of CeIrSi{sub 2} shows a broad maximum at 150 K, characteristic of valence fluctuating Ce-compounds. CeRhSn{sub 2} remains paramagnetic down to 5 K. The resistivity of CeIrSi{sub 2} exhibits a T{sup 2} dependence at low temperatures, indicating a Fermi-liquid ground state, while those of CePdSi{sub 2} and CeRhSn{sub 2} shows the presence of Kondo and crystal field effects. (orig.). 5 refs.

1997-02-01

496

Study of nanocrystallization in FINEMET alloy by active screen plasma nitriding  

International Nuclear Information System (INIS)

The nanocrystallization process of amorphous Fe_7_3_._5Si_1_3_._5B_9Nb_3Cu_1 was investigated by active screen plasma nitriding (ASPN) treatment at temperatures ranging from 410 "oC to 560 "oC for 3 h in two gas mixtures of 75% N_2-25% H_2 and 25% N_2-75% H_2 at 5 mbar atmosphere. The amorphous ribbons were then annealed under vacuum at the same time and temperatures mentioned above. The structure of the samples was analyzed using various techniques such as X-ray diffraction (XRD), atomic force microscopy (AFM) and differential scanning calorimetry (DSC). Microhardness measurements, electrical resistivity and Vibrating Sample Magnetometer (VSM) were used to study mechanical, electrical and magnetic properties of the samples, respectively. It was observed that the ASPN treatment leads to finer grain size and higher crystalline volume fraction and modifies the structural features of Fe(Si) phase. The Fe(Si) lattice parameter for the nitrided ...

2010-02-18

497

Spin freezing in the re-entrant spin glass FeNiMn close to the frustration limit  

Energy Technology Data Exchange (ETDEWEB)

In the invar alloy (Fe{sub 0.65}Ni{sub 0.35}){sub 1-} {sub x} Mn {sub x} we measured the magnetic form factor s(Q) and the intermediate scattering function s(Q,t) for a sample close to the critical Mn concentration (x {sub c}=0.139), at which the sample turns to a re-entrant spin glass phase. The aim was to check whether the magnetic behaviour would approach the Q-independent relaxation behaviour of a classical spin glass when x=x {sub c}. The experiment showed a quite similar spin freezing as for a more ferromagnetic sample with x=0.113. The intermediate scattering function and the form factor were determined by paramagnetic NSE. The normalized scattering function S(Q,t)=s(Q,t)/s(Q)=exp[(-{gamma}t) {sup n}] was fitted by stretched exponential decay. As a function of temperature T<200 K the inverse time constant {gamma} showed the change of more than four orders of magnitude from frozen spin glass (T=60 K to T=100 ...

2007-07-15

498

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are ...

2004-11-01