WorldWideScience
1

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

3

Studying the internal structure of granular magnetic nanocomposites by ferromagnetic resonance  

British Library Electronic Table of Contents (United Kingdom)

A method for estimating the form of magnetic nanoparticles in composite film structures based on the observation of ferromagnetic resonance phenomenon is offered. Within the model of the effective medium, an explanation is given for experimentally observed concentration and temperature dependences of resonant fields for composite nanosystem (Co45Fe45Z10) f +(Al2O3)100?f .

2010-01-01

13

Models of cardiac electromechanics based on individual hearts imaging data  

British Library Electronic Table of Contents (United Kingdom)

Current multi-scale computational models of ventricular electromechanics describe the full process of cardiac contraction on both the micro- and macro- scales including: the depolarization of cardiac cells, the release of calcium from intracellular stores, tension generation by cardiac myofilaments, and mechanical contraction of the whole heart. Such models are used to reveal basic mechanisms of cardiac contraction as well as the mechanisms of cardiac dysfunction in disease conditions. In this paper, we present a methodology to construct finite element electromechanical models of ventricular contraction with anatomically accurate ventricular geometry based on magnetic resonance and diffusion tensor magnetic resonance imaging of the heart. The electromechanical model couples detailed repres...

2011-01-01

14

Fatty acid distribution in systems modeling the normal and diabetic human circulation. A 13C nuclear magnetic resonance study.  

UK PubMed Central (United Kingdom)

A nonperturbing 13C nuclear magnetic resonance (NMR) method was used to monitor the equilibrium distribution of carboxyl 13C-enriched fatty acids (FA) between distinct binding sites on human serum albumin,...Full Text Available

1991-04-01

15

Monitoring of Tumor Promotion and Progression in a Mouse Model of Inflammation-Induced Colon Cancer with Magnetic Resonance Colonography1  

UK PubMed Central (United Kingdom)

Early detection of precancerous tissue has significantly improved survival of most cancers including colorectal cancer (CRC). Animal models designed to study the early stages of cancer are valuable...Full Text Available

2009-03-01

16

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models  

UK PubMed Central (United Kingdom)

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation....Full Text Available

2009-05-01

17

Nuclear magnetic resonance on oriented XVTa and XXTa  

Energy Technology Data Exchange (ETDEWEB)

XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.

1984-08-01

18

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

29

Crossover of the magnetic levels and adiabatic magnetization of the mesoscopic cluster V15  

British Library Electronic Table of Contents (United Kingdom)

The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...

2006-01-01

30

Current applications of magnetic resonance in coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)

1982-01-01

31

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

32

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

33

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

34

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

35

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

36

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

39

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

42

Influence of resonant US on H-NMR at application of magnetic nanoparticles  

International Nuclear Information System (INIS)

2010 [1 p.] Germany Repp, Felix El-Miladi, Nouri Hoehl, Christian Jahanbakhsh,

2010-03-21

45

Nuclear magnetic resonance on oriented "1"7"5Ta and "1"7"7Ta  

International Nuclear Information System (INIS)

"1"7"5Ta and "1"7"7Ta nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies #nu#="+#mu#B sub(HF)/Ih"+ of the "1"7"5Ta and "1"7"7Ta ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of "1"8"1Ta in Fe, the magneticmoments have been deduced: "+#mu#("1"7"5Ta, 7/2"+)"+=2.270(45) and "+#mu#("1"7"7Ta, 7/2"+)"+=2.250(45)#mu# sub(N). These values of the magnetic moments are discussed in the framework of the rotational model. (author).

46

Spontaneous and stimulated Raman studies of vibrational dephasing in condensed phases  

Energy Technology Data Exchange (ETDEWEB)

Vibrational dephasing in condensed phases is studied from both a theoretical and experimental standpoint. A theory is presented which describes the dynamics of motional or exchange processes in weakly perturbed systems. This general formalism, which has been previously used to describe motional narrowing in magnetic resonance, is applied to vibrational spectroscopy. The model treats the case of a high frequency vibration anharmonically coupled to a low-frequency vibration. Intermolecular exchange of low frequency vibrational quanta results in a temperature dependent broadening and frequency shift of the high frequency vibration. Analysis of experimental data by this model yields both the exchange rates and the anharmonic couplings.

1980-05-01

47

Characterization of proton exchange membrane materials for fuel cells by solid state nuclear magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel ...

2010-03-15

48

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate ...

2010-10-01

49

Electron paramagnetic resonance of nitroxide-doped magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.

2002-11-01

50

Anisotropic magnetism in hybridizing uranium systems  

International Nuclear Information System (INIS)

The isostructural uranium monopnictides and monochalcogenides have become prototype systems in actinide research with respect to their unusual magnetic properties. We have investigated the origins in the electronic structure of the variation in magnetic behavior as the degree of 5f-electron localization changes from localized to itinerant on going up the pnictogen or chalcogen column, thus decreasing the U-U separation. We have applied a synthesis of: (1) A phenomenological theory of orbitally driven magnetic ordering which includes both the hybridization-induced and the RKKY exchange interactions on an equal footing, and (2) Ab initio electronic structure calculations, based on the linear-muffin-tin-orbital method, allowing a first-principles evaluation of the parameters entering the model Hamiltonian. We have investigated systematically characteristic trends and changes of the 5f-state ...

51

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the ...

1985-08-01

52

Towards Resonant-State THz Laser Based on Strained p-Ge ...  

Science.gov (United States)

... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...

2006-07-01

53

Tarlov Cyst and Infertility  

UK PubMed Central (United Kingdom)

Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available

2009-04-01

54

Magnetic resonance imaging in human lymphodemas  

International Nuclear Information System (INIS)

The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).

1989-09-02

56

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

57

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends ...

1995-12-31

58

Moderately heavy, heavy-fermion compound YbPd_2Si_2 at low temperatures  

International Nuclear Information System (INIS)

The available experimental data on the specific heat, magnetic susceptibility, magnetization, valence, NMR Knight shift and relaxation rate, and the quadrupolar moment of YbPd_2Si_2 are examined within the framework of the single-ion Anderson model. Such an analysis has previously given excellent agreement between theory and experiment for numerous other light heavy-fermion compounds, where crystalline fields do not play a dominant role. For YbPd_2Si_2, substantial crystalline-field splittings make difficult a quantitative comparison with existing exact solutions of the Anderson model. Inconsistencies with the interpretation that a nearly degenerate ground quadruplet determines the low-temperature thermodynamics are pointed out. It is concluded that at least three of the four Kramers doublets participate in the low-T properties. These three doublets should have a splitting of the order of the Kondo ...

59

Moderately heavy, heavy-fermion compound YbPd sub 2 Si sub 2 at low temperatures  

Energy Technology Data Exchange (ETDEWEB)

The available experimental data on the specific heat, magnetic susceptibility, magnetization, valence, NMR Knight shift and relaxation rate, and the quadrupolar moment of YbPd{sub 2}Si{sub 2} are examined within the framework of the single-ion Anderson model. Such an analysis has previously given excellent agreement between theory and experiment for numerous other light heavy-fermion compounds, where crystalline fields do not play a dominant role. For YbPd{sub 2}Si{sub 2}, substantial crystalline-field splittings make difficult a quantitative comparison with existing exact solutions of the Anderson model. Inconsistencies with the interpretation that a nearly degenerate ground quadruplet determines the low-temperature thermodynamics are pointed out. It is concluded that at least three of the four Kramers doublets participate in the low-{ital T} properties. These three doublets should have a splitting of ...

1992-07-01

60

Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?  

UK PubMed Central (United Kingdom)

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available

2009-03-01

61

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

62

Nuclear magnetic resonance and the question of 5f electron localization in the actinides  

International Nuclear Information System (INIS)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5f electrons. (author).

63

Nuclear magnetic resonance and the question of 5F electron localization in the actinides  

Science.gov (United States)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5Line integral electrons.

1976-01-01

64

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

65

Magnetic resonance appearance of fibromatosis  

International Nuclear Information System (INIS)

We reviewed retrospectively the magnetic resonance (MR) images of 14 soft-tissue lesions of fibromatosis (desmoid tumors) encountered in 11 patients. The lesions were typically inhomogeneous in texture and round to oval in configuration. Margins were well-defined in 78% of the lesions at presentation and were infiltrating in all recurrences. (orig./DG).

66

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

67

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

68

Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness  

UK PubMed Central (United Kingdom)

BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available

69

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

70

Effect of magnet sorting using a simple resonance cancellation method on the RMS orbit distortion at the APS injector synchrotron  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.

1993-07-01

71

Kondo effect in the systems of magnetic trimers on a metal surface  

International Nuclear Information System (INIS)

Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)

2010-11-01

72

Magnetic flocculation and filtration  

Energy Technology Data Exchange (ETDEWEB)

A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.

1996-10-01

73

Determination of Scaling Parameter and Dynamical Resonances in Complex-Rotated Hamiltonian II: Numerical Analysis  

International Nuclear Information System (INIS)

This paper is concerned with the determination of a unique scaling parameter in complex scaling analysis and with accurate calculation of dynamics resonances. In the preceding paper we have presented a theoretical analysis and provided a formalism for dynamical resonance calculations. In this paper we present accurate numerical results for two non-trivial dynamical processes, namely, models of diatomic molecular predissociation and of barrier potential scattering for resonances. The results presented in this paper confirm our theoretical analysis, remove a theoretical ambiguity on determination of the complex scaling parameter, and provide an improved understanding for dynamical resonance calculations in rigged Hilbert space.

2008-03-15

74

Quantum molecular dynamics and molecular interactions studied by NMR and INS[Nuclear magnetic resonance; Proton tunnelling; Hydrogen bond  

Energy Technology Data Exchange (ETDEWEB)

The wavefunction of a particle extends into the classically forbidden barrier region of the potential energy surface. The consequence of this partial delocalisation is the phenomenon of quantum tunnelling, an effect which enables a particle to penetrate a potential barrier of magnitude greater than the energy of the particle. The tunnelling probability is an exponential function of the particle mass. The effect is therefore an important contribution to the behaviour of light atoms, in particular the proton. The hydrogen bond has long been appreciated to be an essential component of many biological and chemical systems, and the proton transfer reaction in the hydrogen bond is fundamental to many of these processes. The proton behaviour in the hydrogen bonds of benzoic acid, acetylacetone and calix-4-arene has been studied. A variety of techniques, both experimental and computational, were adopted for the study of the three hydrogen bonded systems. The complementary spectroscopic ...

2002-07-01

75

Non-white noise in fMRI: does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what ...

2005-01-01

76

Non-white noise in fMRI: Does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what ...

2006-01-01

77

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

78

The Influence of Moderate Hypercapnia on Neural Activity in the Anesthetized Nonhuman Primate  

UK PubMed Central (United Kingdom)

Hypercapnia is often used as vasodilatory challenge in clinical applications and basic research. In functional magnetic resonance imaging (fMRI), elevated CO2 is applied to derive stimulus-induced...Full Text Available

2008-11-01

79

Teaching electron diffraction and imaging of macromolecules.  

UK PubMed Central (United Kingdom)

Electron microscopic analysis can be used to determine the three-dimensional structures of macromolecules at resolutions ranging between 3 and 30 A. It differs from nuclear magnetic resonance spectroscopy...Full Text Available

1993-05-01

80

Synthesis and characterization of PVP-coated large core iron oxide nanoparticles as an MRI contrast agent  

UK PubMed Central (United Kingdom)

The purpose of this study was to synthesize biocompatible polyvinylpyrrolidone (PVP)-coated iron oxide (PVP-IO) nanoparticles and to evaluate their efficacy as a magnetic resonance imaging (MRI)...Full Text Available

2008-04-01

81

Specialization along the Left Superior Temporal Sulcus for Auditory Categorization  

UK PubMed Central (United Kingdom)

The affinity and temporal course of functional fields in middle and posterior superior temporal cortex for the categorization of complex sounds was examined using functional magnetic resonance imaging...Full Text Available

2010-12-01

82

Solid-state 13C NMR spectroscopy of a 13C carbonyl-labeled polypeptide  

UK PubMed Central (United Kingdom)

High resolution structural elucidation of macromolecular structure by solid-state nuclear magnetic resonance requires the preparation of uniformly aligned samples that are isotopically labeled. In...Full Text Available

1992-06-01

83

Retinal channelrhodopsin-2-mediated activity in vivo evaluated with manganese-enhanced magnetic resonance imaging  

UK PubMed Central (United Kingdom)

PurposeEctopic expression of light-sensitive proteins, such as channelrhodopsin-2, represent a novel approach for restoring light-detection capabilities to degenerated retina. A...Full Text Available

84

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

85

Nylon biodegradation by lignin-degrading fungi.  

UK PubMed Central (United Kingdom)

The biodegradation of nylon by lignin-degrading fungi was investigated. The fungus IZU-154 significantly degraded nylon-66 membrane under ligninolytic conditions. Nuclear magnetic resonance analysis...Full Text Available

1997-01-01

86

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

87

New approach to study fast and slow motions in lipid bilayers: application to dimyristoylphosphatidylcholine-cholesterol interactions.  

UK PubMed Central (United Kingdom)

Natural abundance 13C solid-state nuclear magnetic resonance spectroscopy was used to investigate the effect of the incorporation of cholesterol on the dynamics of dimyristoylphosphatidylcholine (DMPC)...Full Text Available

1995-05-01

88

Neurosarcoidosis--demonstration of meningeal disease by gadolinium enhanced magnetic resonance imaging.  

UK PubMed Central (United Kingdom)

Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available

1991-06-01

89

Measuring the thickness of the human cerebral cortex from magnetic resonance images  

UK PubMed Central (United Kingdom)

Accurate and automated methods for measuring the thickness of human cerebral cortex could provide powerful tools for diagnosing and studying a variety of neurodegenerative and psychiatric disorders....Full Text Available

2000-09-26

90

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

91

MRI Findings of Pericardial Fat Necrosis: Case Report  

UK PubMed Central (United Kingdom)

Pericardial fat necrosis is an infrequent cause of acute chest pain and this can mimic acute myocardial infarction and acute pericarditis. We describe here a patient with the magnetic resonance imaging...Full Text Available

2011-05-01

94

Interictal Functional Connectivity of Human Epileptic Networks Assessed by Intracerebral EEG and BOLD Signal Fluctuations  

UK PubMed Central (United Kingdom)

In this study, we aimed to demonstrate whether spontaneous fluctuations in the blood oxygen level dependent (BOLD) signal derived from resting state functional magnetic resonance imaging (fMRI) reflect...Full Text Available

95

In vivo study of chloroplast volume regulation.  

UK PubMed Central (United Kingdom)

This paper describes a new technique that can be used to study chloroplast volume regulation in vivo. Nuclear magnetic resonance spectroscopy was used to measure relative amounts of chloroplast water...Full Text Available

1992-05-01

96

Energy metabolism of the untrained muscle of elite runners as observed by 31P magnetic resonance spectroscopy: evidence suggesting a genetic endowment for endurance exercise.  

UK PubMed Central (United Kingdom)

The purpose of this study was to investigate whether genetically determined properties of muscle metabolism contribute to the exceptional physical endurance of world-class distance runners. ATP, phosphocreatine,...Full Text Available

1988-12-01

97

Effects of norepinephrine infusion on myocardial high-energy phosphate content and turnover in the living rat.  

UK PubMed Central (United Kingdom)

Using 31P-nuclear magnetic resonance, we studied the relationship between myocardial high-energy phosphate content and flux values for the creatine kinase reaction in the living rat under inotropic...Full Text Available

1987-06-01

98

EXPONENTIAL TENSORS: A FRAMEWORK FOR EFFICIENT HIGHER-ORDER DT-MRI COMPUTATIONS  

UK PubMed Central (United Kingdom)

In Diffusion Tensor Magnetic Resonance Image (DT-MRI) processing a 2nd order tensor has been commonly used to approximate the diffusivity function at each lattice...Full Text Available

2007-05-15

99

Current Role and Future Perspectives of Magnetic Resonance Spectroscopy in Radiation Oncology for Prostate Cancer  

UK PubMed Central (United Kingdom)

Prostatic neoplasms are not uniformly distributed within the prostate volume. With recent developments in three-dimensional intensity-modulated and imageguided radiation therapy, it is possible to treat...Full Text Available

2007-06-01

100

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

101

Cardiovascular magnetic resonance guided electrophysiology studies  

UK PubMed Central (United Kingdom)

Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available

102

Calorimetric and spectroscopic studies of the polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines.  

UK PubMed Central (United Kingdom)

The polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines was investigated by differential scanning calorimetry, 31P-nuclear magnetic resonance, and Fourier...Full Text Available

1993-04-01

103

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

104

Polarized proton acceleration at the Brookhaven AGS  

Energy Technology Data Exchange (ETDEWEB)

At the conclusion of polarized proton commissioning in February 1986, protons with an average polarization of 45%, momentum of 21.7 GeV/c, and intensity of 2 x 10/sup 10/ protons per pulse, were extracted to an external polarimeter at the Brookhaven AGS. In order to maintain this polarization, five intrinsic and nearly forty imperfection depolarizing resonances had to be corrected. An apparent interaction between imperfection and intrinsic resonances occurring at very nearly the same energy was observed and the correction of imperfection resonances using ''beat'' magnetic harmonics discovered in the previous AGS commissioning run was further confirmed.

1986-01-01

105

Inborn Errors of Metabolism Presenting in Childhood  

British Library Electronic Table of Contents (United Kingdom)

Abstract Neurodegenerative and neurometabolic disorders may cause significant morbidity and mortality in children. Imaging is important in early diagnosis of metabolic disorders and in determining the extent of brain injury. Especially after the development of new techniques such as diffusion-weighted magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), neuroimaging plays more important role in the diagnosis and management of these disorders. In these disorders, usually a mutation causes a clinically significant block in one or more metabolic pathways. This blockage usually results in either a deficiency of the product or in an accumulation of substrate with damage induced by either storage or toxicity. The presenting symptoms are usually nonspecific. In some of the ...

2011-01-01

106

In vivo magnetic resonance techniques and drug discovery  

International Nuclear Information System (INIS)

The long and resource intensive process of drug discovery and development is confronted with the basic challenge of providing effective and safe therapies at reasonably low costs. The better the mechanism of a disease is known, the higher the probability to find an appropriate therapy. Also, the better and earlier a disease can be diagnosed and characterized, the higher the chance to be able to interfere in this process with a chemical entity. This reasoning sets the framework for the use of imaging in drug discovery. We discuss the relevance of magnetic resonance imaging and spectroscopy to derive anatomical, functional, metabolic and target-related information in the context of pharmacological research in vivo. (author)

2006-03-01

107

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

108

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

109

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

110

Magnetic resonance studies of photosynthetic reaction centers and porphyrins  

Science.gov (United States)

During the period covered by this report research has been concerned with the study of photo-induced electron transfer reactions from porphyrins to acceptor molecules with time-resolved Electron Paramagnetic Resonance (EPR) methods. Excited-state electron transfer reactions are of importance from a fundamental point of view and in connection with applications in homogeneous and heterogeneous photosensitization, photopolymerization, and solar energy conversions. For this reason, the study of photo-induced electron transfer reactions is of considerable interest.

1989-11-01

111

Nuclear magnetic resonance spectroscopy in biomedicine. Course organized by the Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), September 18-23, 1995; Spettroscopia di risonanza magnetica nucleare in biomedicina. Corso organizzato dall`Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), 18-23 settembre 1995  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di ...

1997-12-01

112

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

113

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

114

Resonance scattering of Lyman-. cap alpha. radiation by hydrogen in the ground state  

Energy Technology Data Exchange (ETDEWEB)

We calculate the cross section for the resonance scattering of Lyman-..cap alpha.. radiation by spinless nonrelativistic hydrogen atoms in the ground state using a two-level model. A generalization of Dirac's resonance scattering theory is used together with the exact matrix elements for the electromagnetic interaction. In contrast to the usual treatments in which only the dipole approximation for the matrix elements are taken, the shift in position of the resonance is finite and has a value of 75% of the Lamb shift of the n=1 state. Whether this latter fact is significant in renormalization calculations is left open.

1980-11-01

115

Phenomena of Time Resonances Explosions for the Compound-Clot Decays in High-Energy Nuclear Reactions  

CERN Document Server

The phenomenon of time resonances (or explosions) can explain the exponential reduction of the energy, which is accompanied for the certain degree by slight fluctuations under some conditions in the range of the energy strongly overlapped compound-resonances. These resonant explosions correspond to formation of several highly-exited non-exponentially decaying nuclear clots (partial compound nuclei consisting of several small groups of projectile nucleons and targets). This paper is a continuation and expansion of theoretical authors' work, which is a more general self-consistent version of the time-evolution approach in comparison with the traditional Izumo-Araseki time compound-nucleus model.

2009-01-01

116

Design of a magnetic braking system  

International Nuclear Information System (INIS)

A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted ...

2006-09-01

117

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

118

Nuclear magnetic resonance study of La_3X compounds and related phases  

International Nuclear Information System (INIS)

Normal state nuclear magnetic resonance studies of the La_3In, La_3Tl compounds have been made in order to investigate the origin of the large temperature-dependent magnetic susceptibility. It is possible to analyse the different contributions to the susceptibility using Knight-shift and relaxation time T_1 measurements of In"1"1"5 and Tl"2"0"5 nuclei. The exchange enhancement of the spin-susceptibility chisub(pd) is of the same order as that found in A-15 compounds and the strong temperature-dependence of chi(T) is attributed to the presence of a peak in the electronic density of states near the Fermi level. The variation of the Knight-shift in the ternary alloys La_3Xsub(1-y)Xsub(y)sup(') is analogous to that observed in the corresponding La_3X phases, on the other hand the Knight-shift in the carbides La_3XC is temperature independent. (author).

119

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were presented as color-coded anatomically-mapped ...

120

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high ...

1999-04-01

121

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower ...

1993-06-01

122

Continuum damping of toroidal Alfven eigenmodes in finite-#beta# tokamak equilibria  

International Nuclear Information System (INIS)

A general theoretical approach for the study of the two-dimensional structure of high-n Toroidal Alfven Eigenmodes (TAE) in finite-#beta#, large aspect ratio (R_o/a much-gt 1) tokamak equilibria is presented. Here, n is the toroidal mode number, #beta# = plasma/magnetic pressure, and a(R_o) is the minor (major) radius of the torus. It is shown how the general pseudo-differential boundary value problem for the radial eigenmode structure can be systematically constructed from the local dispersion relation; which is obtained using the ballooning formalism. The TAE modes are characterized by a broad radial envelope, the width of which is independent on the mode number in the general case of monotonic equilibrium profiles. The results on the two-dimensional eigenmode structure are expected to be applicable to drift-type waves. The ballooning transform is generalized here to handle singular eigenfunctions typical of the continuous shear Alfven spectrum, and, thereby, ...

123

Light liquid hydrocarbons from the catalytic pyrolysis of sewage sludge lipid  

Energy Technology Data Exchange (ETDEWEB)

The lipid obtained by the toluene extraction of a dried raw Atlanta sewage sludge by the Soxhlet method, was pyrolyzed over activated alumina at atmospheric pressure. A range of weight hourly space velocities (WHSV) from 0.22-1.60/h and a range of temperatures from 400-480[degree]C were selected. A 70 wt % yield of light liquid hydrocarbons was obtained at a WHSV of 0.46/h and 450[degree]C. The sulfur and nitrogen contents of the pyrolysis products were much lower than products from direct liquefaction of sludge. Infrared spectra and [sup 13]C nuclear magnetic resonance confirmed the absence of carbonyl groups in the products. Gas chromatography showed a uniform hydrocarbon chain length distribution across the C[sub 7] to C[sub 17] mass range. The gas product consisted mainly of carbon dioxide and hydrocarbons. Lauric acid was used as a model to study the decarboxylation. The effects of catalyst loading and catalyst ...

1993-01-01

124

Early effects of boron neutron capture therapy on rat glioma models  

International Nuclear Information System (INIS)

Early effects of boron neutron capture therapy (BNCT) on malignant glioma are characterized by reduction of the enhancement area and regression of the peritumoral edema radiologically. The aim of this study was to investigate the early histological changes of tumors and inflammatory cells after BNCT in the rat brain. Rats were treated with BNCT using boronophenylalanine (BPA) 7 days after implantation of C6 glioma cells. The tumors were assessed with magnetic resonance imaging and histopathological examination at 4 days after BNCT. The mean tumor volumes were 39#+-#2 mm"3 in the BNCT group and 134#+-#18 mm"3 in the control group. In the BNCT group, tumor cells showed a less pleomorphic appearance with atypical nuclei and mitotic figures. The Ki-67 labeling index was 6.5%#+-#4.7% in the BNCT and 35%#+-#3.8% in the control group. The reactions of the inflammatory cells were examined with ED-1 as macrophage marker and OX42 as microglia marker. ...

125

Determination of left ventricular ejection fraction and wall thickness in magnetic resonance imaging at 1.0 Tesla in comparison to echocardiography and biplanar ventriculography  

International Nuclear Information System (INIS)

We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ventriculography (4.5%#+-#10.1). MRI (1.0 T) accurately measures ventricular wall thickness ...

126

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic ...

2009-02-21

127

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic ...

2009-02-21

128

Calculation of atomic spontaneous emission rate in 1D finite photonic crystal with defects  

CERN Document Server

We derive the expression for spontaneous emission rate in finite one-dimensional photonic crystal with arbitrary defects using the effective resonator model to describe electromagnetic field distributions in the structure. We obtain explicit formulas for contributions of different types of modes, i.e. radiation, substrate and guided modes. Formal calculations are illustrated with a few numerical examples, which demonstrate that the application of effective resonator model simplifies interpretation of results.

2009-01-01

129

Model of blood-brain transfer of oxygen explains nonlinear flow-metabolism coupling during stimulation of visual cortex.  

DEFF Research Database (Denmark)

The coupling between cerebral metabolic rate of oxygen (CMRO2) and blood flow (CBF) in response to visual stimulation was evaluated by means of a model of oxygen delivery. The model predicted a nonlinear relationship between stimulus-evoked changes of oxygen consumption and blood flow. The magnitude of the CMRO2/CBF ratio index (IO2) was used to indicate the degree of flow-metabolism coupling prevailing in specific areas of the brain during physiological stimulation. Therefore, the index provided a measure of the blood oxygenation level dependent (BOLD) magnetic resonance contrast. To evaluate the changes of IO2 in response to visual stimulation, the model was applied to the effect of a changing flicker rate of a visual stimulus on the magnitudes of CBF, CMRO2, and oxygen diffusion capacity, in the human brain. Positron emission tomography (PET) was used to measure the CBF and the ...

2000-01-01

130

Ultrasensitive laser isotope analysis in an ion-storage ring  

Energy Technology Data Exchange (ETDEWEB)

We propose a novel method for ultrasensitive isotope analysis that combines magnetic mass selection, resonant charge-exchange neutralization, and resonant laser ionizaion. Our method attains high isotopic abundance selectivity by means of continuous multistage separation of ions stored in a small ring. For the environmentally interesting case of /sup 90/Sr versus /sup 88/Sr we estimate that sensitivity better than 10/sup -15/ for a throughput of 10/sup 13/ atoms/sec and an efficiency (after the ion source) greater than 10% are readily achievable.

1985-09-01

131

Trapping of neutral atoms with resonant microwave radiation  

Energy Technology Data Exchange (ETDEWEB)

We duscuss a resonant microwave trap for neutral atoms. Because of the long spontaneous radiation time this trap is remarkably different from the optical trap. It also has advantages over static magnetic traps that trap the excited spin state of the lowest electronic level, in that atoms predominantly in the spin ground state can be trapped. We analyze the relaxation-ejection lifetime of atoms in such a trap using the formalism of dressed atomic states. Results are appliedi to atomic hydrogen and the possibility of Bose-Einstein condensation is considered.

1989-05-15

132

AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab  

Energy Technology Data Exchange (ETDEWEB)

Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among ...

1992-09-01

133

Nuclear resonant spectroscopy at Bragg reflections from periodic multilayers: Basic effects and applications  

Science.gov (United States)

A systematic study of the Bragg nuclear resonant reflectivity from periodic multilayers in the energy and time domains is presented. Using the kinematical approach of the general reflectivity theory we describe the basic features of the time evolution of the reflected wave after a pulsed excitation of resonant multilayers by synchrotron radiation. Effects of the collective excitation have been examined such as the shift of quantum beat phases, the interplay between electronic and nuclear subsystem excitations depending on their relative position in a multilayer, the energy and time evolution of standing waves inside a resonant multilayer, and their influence on the reflectivity spectra. The exact expression for the reflectivity by a thin resonant layer placed inside a multilayer structure has been derived. The observed shift of the delayed reflectivity Bragg peak relative to the prompt peak is explained ...

2005-09-15

134

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor ...

2005-02-01

135

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in ...

2009-05-15

136

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

137

Multiple resonances and Coulomb blockade splitting in a quantum dot-DNA composite  

British Library Electronic Table of Contents (United Kingdom)

Inspired by the recent realizations of quantum dot (QD)-DNA conjugation, we study the spectral density of a magnetic impurity coupled to a mesoscopic semiconducting host. Using a combination of exact diagonalization technique and an analytic approach, we demonstrate that various types of resonances occur according to the relative position of impurity levels (IL) with respect to the host levels (HL). While the usual Coulomb peaks appear when the IL lie inside a band gap, with IL approaching HL and hybridization activated, they shift nonlinearly with the repulsion strength and even undergo splitting for a strong hybridization. When IL merge into HL, multiple resonances of a comblike structure are found along with a parity effect.

2011-01-01

138

Application of GIS for the evaluation of human exposure to magnetic field in the vicinity of power lines  

Energy Technology Data Exchange (ETDEWEB)

Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.

1998-10-01

139

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

140

Primary cutaneous Ewing's sarcoma/primitive neuroectodermal tumor manifesting numerous small and huge ulcerated masses: its complete remission by chemotherapy and magnetic resonance imaging findings  

International Nuclear Information System (INIS)

Extraskeletal Ewing's sarcoma (ES) and primitive neuroectodermal tumor (PNET) are widely regarded as clinically and histologically identical tumors which consist of small blue round cells. Extraskeletal ESs/PNETs usually occur in the deep soft tissues of the paraspinal region, chest wall, or lower extremities. However, superficially located cases, so-called cutaneous ESs/PNETs, are exceedingly rare, and the vast majority of the reported cases present as a single small mass. We present magnetic resonance imaging (MRI) findings and clinical course of a unique case of primary cutaneous ES/PNET presenting as numerous huge masses with severe ulceration on them. (orig.)

2010-06-01

141

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

142

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection of joint diseases ...

143

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

144

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line ...

2002-08-01

145

Electron cyclotron current drive at {omega} approx. = {omega}{sub c} with X-mode launched from the low field side  

Energy Technology Data Exchange (ETDEWEB)

The electron cyclotron resonance layer in a tokamak, {omega}={omega}{sub c}(r), is not accessible by the extraordinary wave from the low field side, because it is shielded by a cutoff layer. However, a X-mode launched with a nonzero toroidal angle propagates at the cutoff parallel to the magnetic field and has a circular polarization. Therefore it can already at the cutoff layer interact efficiency with electrons via the Doppler shifted resonance. The driven current can be substantially higher than that driven by the second harmonic X-mode. The applicability of this current drive scheme is limited to rather low values of {omega}{sub p}{sup 2}/{omega}{sub c}{sup 2}, but may be of interest for high magnetic field devices. (author)

2000-02-01

146

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

147

Assessment of GABARAP self-association by its diffusion properties  

Energy Technology Data Exchange (ETDEWEB)

Gamma-aminobutyric acid type A receptor-associated protein (GABARAP) belongs to a family of small ubiquitin-like adaptor proteins implicated in intracellular vesicle trafficking and autophagy. We have used diffusion-ordered nuclear magnetic resonance spectroscopy to study the temperature and concentration dependence of the diffusion properties of GABARAP. Our data suggest the presence of distinct conformational states and provide support for self-association of GABARAP molecules. Assuming a monomer-dimer equilibrium, a temperature-dependent dissociation constant could be derived. Based on a temperature series of {sup 1}H{sup 15}N heteronuclear single quantum coherence nuclear magnetic resonance spectra, we propose residues potentially involved in GABARAP self-interaction. The possible biological significance of these observations is discussed with respect to alternative scenarios of oligomerization.

2010-09-15

148

Strength functions of primary transitions following thermal neutron capture in strontium  

Energy Technology Data Exchange (ETDEWEB)

The primary E1, M1 and E2 ..gamma..-radiation in /sup 87,88,89/Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, ..gamma..) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for /sup 90/Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole ...

1989-04-01

149

Strength functions of primary transitions following thermal neutron capture in strontium  

International Nuclear Information System (INIS)

The primary E1, M1 and E2 #gamma#-radiation in "8"7","8"8","8"9Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, #gamma#) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for "9"0Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole ...

150

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research ...

151

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high ...

2008-06-01

152

Numerical study of Cosmic Ray Diffusion in MHD turbulence  

CERN Document Server

We study diffusion of Cosmic Rays (CRs) in turbulent magnetic fields using test particle simulations. Electromagnetic fields are produced in direct numerical MHD simulations of turbulence and used as an input for particle tracing, particle feedback on turbulence being ignored. Statistical transport coefficients from the test particle runs are compared with earlier analytical predictions. We find qualitative correspondence between them in various aspects of CR diffusion. In the incompressible case, that we consider in this paper, the dominant scattering mechanism occurs to be the non-resonant mirror interactions with the slow-mode perturbations. Perpendicular transport roughly agrees with being produced by magnetic field wandering.

2010-01-01

153

Moxel: A molar tooth voxel model for dosimetric studies  

Energy Technology Data Exchange (ETDEWEB)

Stylized numerical models of the tooth are usually employed in qualification procedure related to Electronic Paramagnetic Resonance in long-term accidental contamination dose reconstruction. In this work a voxel model was developed from the microCT image data set of a human non contaminated molar tooth. A stylized model, reproducing the characteristics of the voxel model, was also created in order to investigate the level of accuracy that can be obtained in this kind of study.

2010-02-15

154

Quark-Hadron Duality: Resonances and the Onset of Scaling  

Energy Technology Data Exchange (ETDEWEB)

We discuss the origin of Bloom-Gilman duality and the relationship between resonances and scaling in deep-inelastic scattering. We present a simple quantum mechanical model which reproduces the essential features of Bloom-Gilman duality at low Q{sup 2}, and describe applications of local duality relating structure functions at x{approximately}1 and elastic electromagnetic form factors.

2001-03-01

155

Roles of the #beta# 146 histidyl residue in the molecular basis of the Bohr Effect of hemoglobin: A proton nuclear magnetic resonance study  

International Nuclear Information System (INIS)

Assessment of the roles of the carboxyl-terminal #beta#146 histidyl residues in the alkaline Bohr effect in human and normal adult hemoglobin by high-resolution proton nuclear magnetic resonance spectroscopy requires assignment of the resonances corresponding to these residues. By a careful spectroscopic study of human normal adult hemoglobin, enzymatically prepared des(His146#beta#)-hemoglobin, and the mutant hemoglobins Cowtown (#beta#146His #-># Leu) and York (#beta#146His #-># Pro), the authors have resolved some of these conflicting results. By a close incremental variation of pH over a wide range in chloride-free 0.1 M N-(2-hydroxyethyl)piperazine-N'-2-ethanesulfonic acid buffer, a single resonance has been found to be consistently missing in the proton nuclear magnetic resonance spectra of these hemoglobin variants. The results indicate that the ...

156

Performance of hole coupling resonator in the presence of asymmetric modes and FEL gain  

Energy Technology Data Exchange (ETDEWEB)

We continue the study of the hole coupling resonator for free electron laser (FEL) application. The previous resonator code is further developed to include the effects of the azimutally asymmetric modes and the FEL gain. The implication of the additional higher order modes is that there are more degeneracies to be avoided in tuning the FEL wavelengths. The FEL interaction is modeled by constructing a transfer map in the small signal regime and incorporating it into the resonator code. The FEL gain is found to be very effective in selecting a dominant mode from the azimuthally symmetric class of modes. Schemes for broad wavelength tuning based on passive mode control via adjustable apertures are discussed. 12 refs., 7 figs., 1 tab.

1991-08-01

157

Recycler model magnet test on temperature compensation for strontium ferrite  

Energy Technology Data Exchange (ETDEWEB)

The Recycler ring magnet will be made of Strontium ferrite permanent magnets. A strontium ferrite permanent magnet without compensation has a temperature coefficient of -0.2 % in dB/dT. To compensate this effect, we are utilizing 30 % Ni 70 % Fe alloy, a temperature compensation ferromagnetic material with a low Curie point. To search for optimum commercially available material and optimum condition, we made a couple of simple model magnets, and tested with several different compensating material. The test results are reported and its optimal conditions are shown. Several different configurations were tested including a possible 2 kG magnet configuration.

1995-10-01

158

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

159

The brain-derived neurotrophic factor Val66Met polymorphism is associated with reduced functional magnetic resonance imaging activity in the hippocampus and increased use of caudate nucleus-dependent strategies in a human virtual navigation task  

UK PubMed Central (United Kingdom)

Multiple memory systems are involved in parallel processing of spatial information during navigation. A series of studies have distinguished between hippocampus-dependent ‘spatial’ navigation,...Full Text Available

2011-03-01

160

Structure of a mycobacterial polysaccharide-fatty acyl-CoA complex: nuclear magnetic resonance studies.  

UK PubMed Central (United Kingdom)

MMP, a linear alpha 1 leads to 4 linked polymer of 3-O-methylmannose, regulates the fatty acid synthetase from Mycobacterium smegmatis by forming stoichiometric complexes with the long-chain acyl-CoA...Full Text Available

1980-05-01

161

Right-sided invasive metastatic thymoma of the heart  

British Library Electronic Table of Contents (United Kingdom)

Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.

2011-01-01

162

Quality control in Nuclear Magnetic Resonance Imaging. Indications et strategies pour le controle de qualite en IRM  

Energy Technology Data Exchange (ETDEWEB)

In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.

1993-01-01

163

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

164

Metastatic Ewing's sarcoma to the skull: CNS involvement excluded by MRI  

International Nuclear Information System (INIS)

A case of metastatic Ewing's sarcoma to the skull is presented, demonstrating the superiority of magnetic resonance imaging over other imaging modalities to exclude CNS involvement. Precise delineation of different tumor components in extradural location contained in an intact dural rim together with compressed cortex showing no signs of tumorous involvement constituted an MRI appearance allowing us to exclude tumor outgrowth into the brain. (orig.).

165

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

166

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

167

MRI and 1H MRS of The Breast: Presence of a Choline Peak as Malignancy Marker is Related to k21 Value of the Tumor in Patients with Invasive Ductal Carcinoma  

UK PubMed Central (United Kingdom)

To assess which specific morphologic features, enhancement patterns, or pharmacokinetic parameters on breast Magnetic Resonance Imaging (MRI) could predict a false-negative outcome of Proton...Full Text Available

2008-01-01

168

MR findings of primary Ewing's sarcoma of greater wing of sphenoid  

International Nuclear Information System (INIS)

Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd

2002-12-01

169

Hyperfine interactions in HCOOD and DCOOH molecules  

Energy Technology Data Exchange (ETDEWEB)

The method of double microwave--radio-frequency resonance has been used to obtain spectra of the 2/sub 11/reverse arrow2/sub 12/ and 3/sub 21/reverse arrow3/sub 22/ transitions in HCOOD, DCOOH, and HCOOH molecules. The constants of the quadrupole bond of the deuterons have been determined, magnetic interactions being taken into acocunt. A comparison with results of previous studies is given.

1986-05-01

170

Electron phonon properties of A-15 compounds and Chevrel phases  

International Nuclear Information System (INIS)

A review of the information on the electron and phonon spectra in the A-15 compounds and Chevrel phase superconductors obtained from nuclear magnetic resonance, heat capacity, and Moessbauer effect experiments is presented. Relationships of the Fermi energy electrons and the soft phonons to the strength of the electron-phonon interaction are discussed.

171

Electron and phonon properties of A-15 compounds and Chevrel phases  

International Nuclear Information System (INIS)

A review of the information on the electron and phonon spectra in the A-15 compounds and Chevrel phase superconductors obtained from nuclear magnetic resonance, heat capacity, and Moessbauer effect experiments is presented. Relationships of the Fermi energy electrons and the soft phonons to the strength of the electron-phonon interaction are discussed.

172

Effect of Elicitation and Changes in Extracellular pH on the Cytoplasmic and Vacuolar pH of Suspension-Cultured Soybean Cells 1  

UK PubMed Central (United Kingdom)

We have employed both 31P nuclear magnetic resonance spectroscopy and two intracellular fluorescent pH indicator dyes to monitor the pH of the vacuole and cytoplasm of suspension-cultured...Full Text Available

1992-02-01

173

Characterization of polymers for microcellular foams  

Energy Technology Data Exchange (ETDEWEB)

We have measured, by {sup 1}H and {sup 13}C nuclear magnetic resonance (NMR), the percent deuteration, the tacticity and the purity of several polymers and one solvent used in the preparation of microcellular foams. The percent deuteration was measured for polystyrene, polyacrylonitrile and polyethylene. The tacticities of polystyrene and polyacrylonitrile were determined. The purity and degradation products of polyacrylonitrile and maleic anhydride were examined. This report documents the experimental procedures and results of these measurements.

1992-03-01

174

31P NMR Observations on the Effect of the External pH on the Intracellular pH Values in Plant Cell Suspension Cultures 1  

UK PubMed Central (United Kingdom)

31P nuclear magnetic resonance (NMR) spectroscopy was used to monitor the response of oil palm (Elaeis guineensis) and carrot (Daucus carota) cell suspensions...Full Text Available

1990-06-01

175

Spatial Damping of Propagating Kink Waves Due to Resonant Absorption: Effect of Background Flow  

CERN Document Server

Observations show the ubiquitous presence of propagating magnetohydrodynamic (MHD) kink waves in the solar atmosphere. Waves and flows are often observed simultaneously. Due to plasma inhomogeneity in the perpendicular direction to the magnetic field, kink waves are spatially damped by resonant absorption. The presence of flow may affect the wave spatial damping. Here, we investigate the effect of longitudinal background flow on the propagation and spatial damping of resonant kink waves in transversely nonuniform magnetic flux tubes. We combine approximate analytical theory with numerical investigation. The analytical theory uses the thin tube (TT) and thin boundary (TB) approximations to obtain expressions for the wavelength and the damping length. Numerically, we verify the previously obtained analytical expressions by means of the full solution of the resistive MHD eigenvalue problem beyond the TT ...

2011-01-01

176

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists ...

1991-09-15

177

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are ...

2004-11-01

178

Magnetic Moments and Electromagnetic Radii of Nucleon and ?(1232) in an Extended Goldstone-Boson-Exchange Model  

International Nuclear Information System (INIS)

We derive the exchange currents of pseudoscalar, vector, and scalar mesons from Feynman diagrams, and use them to calculate the magnetic form factors of nucleon and ?(1232). The magnetic moments and electromagnetic radii are obtained by using those form factors and the parameters determined from the masses of nucleon and ?(1232). We find the magnetic moments and electromagnetic radii of nucleon and ?(1232) can be produced very well in the extended Goldstone-Boson-exchange model in which all of pseudoscalar, vector, and scalar meson nonet are included. The magnetic moments of ?(1232) are closer to experiment values and results from lattice calculation than the results obtained by the model without other mesons except for pion and sigma.

2005-01-15

179

Optical Feshbach Resonances in Alkaline Earth Atoms  

Science.gov (United States)

Recent proposals have shown that a quantum degenerate gas of alkaline earth atoms can be used for a number of novel quantum computing and quantum simulation experiments. Strontium is a good candidate for such experiments because it can be controlled with high precision, as demonstrated in recent atomic clock experiments. Unfortunately, the small scattering length of strontium is not amenable to evaporative cooling techniques that are used to reach quantum degeneracy. Furthermore, increasing the scattering length of alkaline earths with a magnetic Feshbach resonance is not possible due to their spinless electronic ground state configuration. However, recent theoretical and experimental work suggests the possibility of changing scattering lengths in alkaline earths with laser light. Using this optical Feshbach resonance near strontium's narrow ^1S0->^3P1 intercombination transition might allow its scattering length to be ...

2009-10-01

180

The magnetic resonance and its agro-industry applications; a review  

International Nuclear Information System (INIS)

The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage and conservation of ...

181

Modelling fragmentations of amino-acids after resonant electron attachment: quantum evidence of possible direct -OH detachment  

International Nuclear Information System (INIS)

We investigate some aspects of the radiation damage mechanisms in biomolecules, focusing on the modelling of resonant fragmentation caused by the attachment of low-energy electrons (LEEs) initially ejected by biological tissues when exposed to ionizing radiation. Scattering equations are formulated within a symmetry-adapted, single-center expansion of both continuum and bound electrons, and the interaction forces are obtained from a combination of ab initio calculations and a nonempirical model of exchange and correlation effects developed in our group. We present total elastic scattering cross-sections and resonance features obtained for the equilibrium geometries of glycine, alanine, proline and valine. Our results at those geometries of the target molecules are briefly shown to qualitatively explain some of the fragmentation patterns obtained in experiments. We further carry out a one-dimensional ...

2010-10-01

182

Modeling paraxial wave propagation in free-electron laser oscillators  

International Nuclear Information System (INIS)

Modeling free-electron laser (FEL) oscillators requires calculation of both the light-beam interaction within the undulator and the light propagation outside the undulator. We have developed a paraxial optical propagation code that can be combined with various existing models of gain media, for example, Genesis 1.3 for FELs, to model oscillators with full paraxial wave propagation within the resonator. A flexible scripting interface is used both to describe the optical resonator and to control the codes for propagation and amplification. To illustrate its capabilities, we numerically investigate two significantly different FEL oscillators: the free-electron laser for infrared experiments (FELIX) system and the vacuum-ultraviolet (VUV)-FEL oscillator of the proposed high-gain fourth generation light source. For the FELIX system, we find that diffraction losses are a considerable part ...

2006-11-01

183

ESR studies of spin-labeled membranes aligned by isopotential spin-dry ultracentrifugation: lipid-protein interactions.  

UK PubMed Central (United Kingdom)

Electron spin resonance (ESR) studies have been performed on spin-labeled model membranes aligned using the isopotential spin-dry ultracentrifugation (ISDU) method of Clark and Rothschild. This method...Full Text Available

1994-12-01

184

Duality in Neutrino Reactions  

Energy Technology Data Exchange (ETDEWEB)

On the basis of the phenomenological model for baryon resonance production in lepton nucleon and lepton nucleus scattering we investigate to what extent quark hadron duality is applicable to the neutrino structure functions and how it compares with duality in electron scattering.

2007-12-01

185

Frontopolar and anterior temporal cortex activation in a moral judgment task. Preliminary functional MRI results in normal subjects  

International Nuclear Information System (INIS)

The objective was to study the brain areas which are activated when normal subjects make moral judgments. Ten normal adults underwent BOLD functional magnetic resonance imaging (fMRI) during the auditory presentation of sentences that they were instructed to silently judge as either 'right' or 'wrong'. Half of the sentences had an explicit moral content ('We break the law when necessary'), the other half comprised factual statements devoid of moral connotation ('Stones are made of water'). After scanning, each subject rated the moral content, emotional valence, and judgment difficulty of each sentence on Likert-like scales. To exclude the effect of emotion on the activation results, individual responses were hemo dynamically modeled for event-related f MRI analysis. The general linear model was used to evaluate the brain areas activated by moral judgment. Regions activated during moral judgment included ...

2001-09-01

186

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

187

Fitting the fully coupled ORM for the Fermilab Booster  

Energy Technology Data Exchange (ETDEWEB)

The orbit response matrix (ORM) method [1] is applied to model the Fermilab Booster with parameters such as the BPM gains and rolls, and parameters in the lattice model, including the gradient errors and magnets rolls. We found that the gradients and rolls of the adjacent combined-function magnets were deeply correlated, preventing full determination of the model parameters. Suitable constraints of the parameters were introduced to guarantee an unique, equivalent solution. Simulations show that such solution preserves proper combinations of the adjacent parameters. The result shows that the gradient errors of combined-function magnets are within design limits.

2005-05-01

188

Efficient Cartesian-grid-based modeling of rotationally symmetric bodies  

DEFF Research Database (Denmark)

Axially symmetric waveguides, resonators, and scatterers of arbitrary cross section and anisotropy in the cross section can be modeled rigorously with use of 2-D Cartesian-grid based codes by means of mere redefinition of material permittivity and permeability profiles. The method is illustrated by the frequencydomain simulations of resonant modes in a circular-cylinder cavity with perfectly conducting walls, a shielded uniaxial anisotropic dielectric cylinder, and an open dielectric sphere for which, after proper implementation of the perfectly matched layer boundary conditions, the radiation quality factor is also determined.

2007-01-01

189

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which ...

1998-05-01

190

Locally resonant acoustic metamaterials with 2D anisotropic effective mass density  

British Library Electronic Table of Contents (United Kingdom)

A two-dimensional (2D) lattice model with anisotropic resonant microstructures is found to provide an anisotropic band gap structure. A 2D continuum with anisotropic effective mass density is introduced to represent this lattice system. Two methods are proposed to derive the equivalent continuum. In the first method, the effective mass density of the equivalent continuum is obtained by matching the dispersion relations for harmonic waves propagating in the principal directions. The second approach employs an approximate estimation of the effective mass density by volume-averaging an effective mass that represents the resonant microstructure. For both equivalent continuum models, the effective mass density is frequency-dependent and may become negative in certain frequency ranges. Subsequen...

2011-01-01

191

REALISTIC NON-LINEAR MODEL AND FIELD QUALITY ANALYSIS IN RHIC INTERACTION REGIONS.  

Energy Technology Data Exchange (ETDEWEB)

The existence of multipole components in the dipole and quadrupole magnets is one of the factors limiting the beam stability in the RHIC operations. So, a realistic non-linear model is crucial for understanding the beam behavior and to achieve the ultimate performance in RHIC. A procedure is developed to build a non-linear model using the available multipole component data obtained from measurements of RHIC magnets. We first discuss the measurements performed at different stages of manufacturing of the magnets in relation to their current state in RHIC. We then describe the procedure to implement these measurement data into tracking models, including the implementation of the multipole feed down effect due to the beam orbit offset from the magnet center. Finally, the field quality analysis in the RHIC interaction regions (IR) is presented.

2007-06-25

193

Self-simulating motion of an ionized gas expelled by a magnetic piston  

Energy Technology Data Exchange (ETDEWEB)

The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.

1980-01-01

194

Instability of 4f and 3d magnetic moments under high pressure  

International Nuclear Information System (INIS)

The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).

195

Resistivity, Hall effect, and magnetic susceptibility of UPd_2Si_2  

International Nuclear Information System (INIS)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

196

Resistivity, Hall effect, and magnetic susceptibility of UPd[sub 2]Si[sub 2  

Energy Technology Data Exchange (ETDEWEB)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

1993-12-15

197

Nature of the magnetic susceptibility of dysprosium. Paramagnetic susceptibility of dysprosium - yttrium alloys  

International Nuclear Information System (INIS)

The paramagnetic susceptibility of single crystals of dysprosium-yttirum alloys is measured in the basal plane and along the hexagonal axis. It is shown that the susceptibility of the alloys obeys the Curie-Weiss law, the effective magnetic moments allong the different directions being the same and the paramagnetic Curie temperatures being different. The difference between the paramagnetic Curie temperatures in the basal plane and along the hexagonal axis is independent of the dysprosium concentration in the alloy. As a comparison with the theoretical models of magnetic anisotropy shows, this is an indication that the magnetic anisotropy of dysprosium - yttrium alloys is of a single-ion nature.

1976-01-01

198

Structure and magnetic properties of the UNi_1_0_-_xFe_xSi_2 system and "2"9Si nuclear magnetic resonance in UNi_1_0Si_2  

International Nuclear Information System (INIS)

Structure and magnetic properties of UNi_1_0_-_xFe_xSi_2 intermetallics and "2"9Si nuclear magnetic resonance (NMR) in UNi_1_0Si_2 are investigated in a wide temperature range. Solid solutions in the exactly single-phase tetragonal form, ThMn_1_2 type, exist for x<2. The Ni and Fe atoms occupy the 8(f), 8(i) and 8(j) positions statistically, whereas the U atoms occupy the 2(a) and the Si atoms the 8(j) sites. The lattice parameters roughly follow Vegard's law. The magnetic susceptibility does not exhibit Curie-Weiss behaviour and, at about 630 K, an anomaly in the temperature dependence is observed. At low temperature, other anomalies are observed at 32 K and 45 K, for x=0.5 and 1.0 respectively. These low temperature anomalies are probably connected with magnetic ordering of a ferromagnetic character, whereas that at 630 K might result from the superparamagnetic state of Ni. Two ...

1993-09-01

199

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically ...

1997-01-01

200

On the plasma rotation in a straight magnetized filter of a pulsed vacuum arc  

International Nuclear Information System (INIS)

In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is ...

2007-01-21

201

A classical model for the magnetic field-induced Wigner crystallization in quantum dots  

Energy Technology Data Exchange (ETDEWEB)

A classical model is presented for magnetic field-induced Wigner crystallization in electron systems confined within two-dimensional quantum dots. In contrast to other classical models, this one does not treat an electron as a point charge; the electron density is assumed to take a Gaussian form corresponding to the lowest Landau level. Using a Monte Carlo method we have determined the equilibrium configurations as functions of the magnetic field. We have found a classical counterpart of the quantum maximum density droplet (MDD) and studied the breakdown of the MDD into a Wigner molecule as well as the transformations of the Wigner molecule shape induced by the external magnetic field. The phase diagram for the classical Wigner molecules has been presented and its qualitative agreement with previous quantum mechanical calculations has been shown.

2004-03-03

202

A dinuclear Ni(I) system having a diradical Ni2N2 diamond core resting state: synthetic, structural, spectroscopic elucidation, and reductive bond splitting reactions.  

Science.gov (United States)

One-electron reduction of the square-planar nickel precursor (PNP)NiCl ( 1) (PNP (-) = N[2-P(CHMe 2) 2-4-methylphenyl] 2) with KC 8 effects ligand reorganization of the pincer ligand to assemble a Ni(I) dimer, [Ni(mu 2-PNP)] 2 ( 2), containing a Ni 2N 2 core structure, as inferred by its solid-state X-ray structure. Solution magnetization measurements are consistent with a paramagnetic Ni(I) system likely undergoing a monomer dimer equilibrium. The room-temperature and 4 K solid-state X-band electron paramagnetic resonance (EPR) spectra display anisotropic signals. Low-temperature solid-state X-band EPR data at 4 K reveal rhombic values g z = 1.980(4), g x = 2. 380(4), and g y = 2.225(4), as well as a forbidden signal at g = 4.24 for the Delta M S = 2 half field transition, in accord with 2 having two weakly interacting metal centers. Utilizing an S = 1 model, full spin Hamiltonian simulation of the low-temperature EPR ...

2008-10-15

203

Towards a realistic model of Fe-Cu-Fe spin valve systems using tight-binding methods  

Energy Technology Data Exchange (ETDEWEB)

Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.

1996-12-31

204

Magnetic resonance imaging of cerebral anomalies in subjects with resistance to thyroid hormone  

Energy Technology Data Exchange (ETDEWEB)

Resistance to thyroid hormone (RTH) is an autosomal dominant disease caused by mutations in the human thyroid receptor beta gene on chromosome 3. Individuals with RTH have an increased incidence of attention deficit hyperactivity disorder (ADHD). The purpose of this study was to search for developmental brain malformations associated with RTH. Forty-three subjects (20 affected males [AM], 23 affected females [AF]) with resistance to thyroid hormone and 32 unaffected first degree relatives (18 unaffected males [UM], 14 unaffected females [UF]) underwent MRI brain scans with a volumetric acquisition that provided 90 contiguous 2 mm thick sagittal images. Films of six contiguous images beginning at a standard sagittal position lateral to the insula were analyzed by an investigator who was blind with respect to subject characteristics. The presence of extra or missing gyri in the parietal bank of the Sylvian fissure (multimodal association cortex) and multiple Heschl`s transverse gyri ...

1995-06-19

205

X-point model for magnetic susceptibility of A-15 compounds  

Science.gov (United States)

The X-point linear chain model for electronic structure of A-15 compounds is shown to lead to a weakly temperature dependent magnetic susceptibility ?(T) = 3micro2?N(0) tanh (?~ / T) is serious disagreement with experiment. Supported in part by NSF-DMR76-20641; AROD-DAHCO4-75-G-0052; and FRAP-CUNY 11453.

1977-11-01

206

Spin polarization and structure of the sup(181, 182, 187)Re and "1"7"7Ta states  

International Nuclear Information System (INIS)

The properties of "1"7"7Ta and sup(181, 182, 187)Re states are discussed in the framework of the rotational model with the Coriolis coupling. The relations are obtained for calculating magnetic moments by this model in the jlK representation. The valent-nucleon spin polarization found on the basis of a comparison of the experimental values of magnetic moments with the calculated ones, is shown to depend on the number of nucleons of the same type.

1978-03-01

207

Application of a new three-dimensional k.p model for the A-15 crystals to the properties of V3 Si  

Science.gov (United States)

The new three-dimensional k.p model for the electronic structure of A-15 compounds gives satisfactory results for the magnetic susceptibility; shear modulus; tetragonal strain at the transition temperature Tm; and the magnetic field effect on Tm and shear mode sound velocity. Supported by NSF grant # DMR76-02043.

1977-11-01

208

Resonances in gravitational scenario given by deformed branes  

Science.gov (United States)

In this work we examine a five-dimensional brane-world model with brane structure driven by a real scalar field. From the deformation of a kink-like defect we find a new class of brane solutions containing internal structures which have implications for the way the background space-time is constructed and the way its curvature behaves. Initially, for spin 0 scalar field, we find a zero mode which can be localized on the deformed brane. However, this result can change by the gravitational interaction with the brane internal structure. Analyzing the massive modes of the scalar field, using two different methods, we find resonance structures similar to those found in the study of gravity localization. The main objective here is to observe the contributions of the deformation procedure to the resonances and to the well known field localization methods.

2011-08-01

209

New 88Sr(n,g)Astrophysical Reaction Rate from Resonance Analysis of New High-Resolution Neutron Capture and Transmission Data  

Science.gov (United States)

Because of its small cross section, the 88Sr(n,g) reaction is an important bottleneck during s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. We have completed the resonance analysis of our new and improved measurements of the neutron capture and total cross sections for 88Sr made at the Oak Ridge Electron Linear Accelerator (ORELA). We describe our experimental procedures and resonance analysis, compare our results to previous data, and discuss their astrophysical impact.

1999-08-30

210

Description of T/sub greater-than/ giant resonances in spherical nuclei  

Energy Technology Data Exchange (ETDEWEB)

Formulas are obtained for calculation of the energies and B(Elambda) values of T/sub greater-than/ giant resonances in the quasiparticle-phonon model of the nucleus. Characteristics of giant dipole resonances are calculated in several spherical nuclei and the correct location is obtained for T/sub less-than/ and T/sub greater-than/ collective 1/sup -/ states. The calculated ratios sigma/sub -/1(T/sub greater-than/)/sigma/sub -/1(T/sub less-than/) agree with the experimental data for /sup 88/Sr, /sup 90/Zr, and /sup 92/Mo and are 3 times larger than the experimental values for /sup 116,120,124/Sn. The decrease of the cross sections sigma/sub -/1(T/sub greater-than/) in /sup 124/Sn in comparison with /sup 116/Sn is correctly reproduced.

1982-03-01

211

Low-frequency fields - sources and exposure; Niederfrequente Felder - Quellen und Exposition  

Energy Technology Data Exchange (ETDEWEB)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe) [Deutsch] Nach einer kurzen Diskussion der Begriffsdefinitionen und einer Einfuehrung in die Messtechnik werden die Charakteristika verschiedener ...

1993-06-01

212

Disturbance Rejection Control of an Electromagnetic Bearing Spindle  

Energy Technology Data Exchange (ETDEWEB)

The force exerted on the rotor by an active magnetic bearing (AMB) is determined by the current flow in the magnet coils. This force can be controlled very precisely, making magnetic bearings a potential benefit for grinding, where cutting forces act as external disturbances on the shaft, resulting in degraded part finish. It is possible to achieve precise shaft positioning, reduce vibration of the shaft caused by external disturbances, and even damp out resonant modes. Adaptive control is an appealing approach for these systems because the controller can tune itself to account for an unknown periodic disturbance, such as cutting or grinding forces, injected into the system. In this paper the authors show how one adaptive control algorithm can be applied to an AMB system with a periodic disturbance applied to the rotor. An adaptive algorithm was developed and implemented in both simulation and hardware, ...

2000-08-31

213

Time-resolved resonance and linewidth of an ultrafast switched GaAs/AlAs microcavity  

CERN Document Server

We explore a planar GaAs/AlAs photonic microcavity using pump-probe spectroscopy. Free carriers are excited in the GaAs with short pump pulses. The time-resolved reflectivity is spectrally resolved short probe pulses. We show experimentally that the cavity resonance and its width depend on the dynamic refractive index of both the lambda-slab and the lambda/4 GaAs mirrors. We clearly observe a double exponential relaxation of both the the cavity resonance and its width, which is due to the different recombination timescales in the lambda-slab and the mirrors. In particular, the relaxation time due to the GaAs mirrors approaches the photon storage time of the cavity, a regime for which nonlinear effects have been predicted. The strongly non-single exponential behavior of the resonance and the width is in excellent agreement to a transfer-matrix model taking into account two recombination times. The change ...

2009-01-01

214

Acoustic metamaterials for sound focusing and confinement  

Energy Technology Data Exchange (ETDEWEB)

We give a theoretical design for a locally resonant two-dimensional cylindrical structure involving a pair of C-shaped voids in an elastic medium which we term as double 'C' resonators (DCRs) and imbedded thin stiff bars, that displays the negative refraction effect in the low frequency regime. DCRs are responsible for a low frequency band gap which hybridizes with a tiny gap associated with the presence of the thin bars. Using an asymptotic analysis, typical working frequencies are given in closed form: DCRs behave as Helmholtz resonators modeled by masses connected to clamped walls by springs on either side, while thin bars behave as a periodic bi-atomic chain of masses connected by springs. The discrete models give an accurate description of the location and width of the stop band in the case of the DCR and the first two dispersion bands for the periodic thin ...

2007-11-15

215

Acoustic metamaterials for sound focusing and confinement  

International Nuclear Information System (INIS)

We give a theoretical design for a locally resonant two-dimensional cylindrical structure involving a pair of C-shaped voids in an elastic medium which we term as double 'C' resonators (DCRs) and imbedded thin stiff bars, that displays the negative refraction effect in the low frequency regime. DCRs are responsible for a low frequency band gap which hybridizes with a tiny gap associated with the presence of the thin bars. Using an asymptotic analysis, typical working frequencies are given in closed form: DCRs behave as Helmholtz resonators modeled by masses connected to clamped walls by springs on either side, while thin bars behave as a periodic bi-atomic chain of masses connected by springs. The discrete models give an accurate description of the location and width of the stop band in the case of the DCR and the first two dispersion bands for the periodic thin bars. We then ...

2007-11-01

216

New short-range electromagnetic current in the deuteron  

International Nuclear Information System (INIS)

A new model for short-range isoscalar current in the deuteron and NN system is developed and tested on a variety of isoscalar magnetic observables such as the deuteron magnetic moment, magnetic form factor, and the circular polarization of photons at n"#->#p radiative capture at thermal neutron energies. The model for electromagnetic two-nucleon current proposed in the paper is based on generation of an intermediate dibaryon in the short-range NN interaction. This intermediate dibaryon, in turn, is treated within the new model for intermediate and short-range NN interaction recently proposed by the present authors. The transition current model developed here satisfies the current conservation relation by the construction. Our calculations have demonstrated that the new current model, using only one parameter (with a ...

2007-02-01

217

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Science.gov (United States)

The dynamic response characteristics of the VAWT rotor are important factors governing the safety and fatigue life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. This paper will describe and discuss the primary tools now in use at Sandia National Laboratories for rotor analysis. These tools include a lumped springmass model (VAWTDYN) and also finite-element based approaches. The discussion will center on the accuracy and completeness of current capabilities and plans for future research.

1981-01-01

218

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Science.gov (United States)

The dynamic response characteristics of the vertical axis wind turbine (VAWT) rotor are important factors governing the safety and fatigue life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and Coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. The primary tools now in use for rotor analysis are described and discussed. These tools include a lumped spring mass model (VAWTDYN) and also finite-element based approaches. The accuracy and completeness of current capabilities are also discussed.

1981-05-01

219

Test Bed for Superconducting Materials  

Energy Technology Data Exchange (ETDEWEB)

Superconducting rf cavities are increasingly used in accelerators. Gradient is a parameter of particular importance for the ILC. Much progress in gradient has been made over the past decade, overcoming problems of multipacting, field emission, and breakdown triggered by surface impurities. However, the quenching limit of the surface magnetic field for niobium remains a hard limitation on cavity fields sustainable with this technology. Further exploration of materials and preparation may offer a path to surpassing the current limit. For this purpose, we have designed a resonant test cavity. One wall of the cavity is formed by a flat sample of superconducting material; the rest of the cavity is copper or niobium. The H field on the sample wall is 75% higher than on any other surface. Multipacting is avoided by use of a mode with no surface electric field. The cavity will be resonated through a coupling iris with high-power rf ...

2006-01-30

220

Study of praseodymium complexing with ethylenediaminetetraacetic acid by proton magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

The method of proton magnetic resonance (PMR) has been used to study the mechanism of reaction of complexing of paramagnetic Pr/sup 3 +/ ion with ethylenediaminetetra acetic acid (EDTA). The influence of medium acidity (pH5-12), EDTA/Pr ratio varying from 1 to 50, Pr/sup 3 +/ ion concentration (from 5x10/sup -3/ to 3x10/sup -1/ g-ion/l) and temperature (8-98 deg C) on chemical shifts and broadening of signals of EDTA molecule protons is investigated. Data on ratio of components, coordination and stability of forming complexes are obtained. The existence of two types of complexes with the Pr/EDTA ratio equal to 1:1 and 1:2 has been found. Equimolecular complex (1:1) is stable all over the studied temperature interval in contrast to the complex 1:2 for which at 50 deg C fast extrasphere exchange (Pr EDTA)EDTA * + EDTA/sup 0/ reversible (PrEDTA)EDTA/sup 0/ + EDTA * is observed, while at t=98 deg C intrasphere exchange (PrEDTA)EDTA * reversible ...

1983-05-01

221

Proton magnetic resonance spectroscopy reflects cellular proliferative activity in astrocytomas  

International Nuclear Information System (INIS)

We examined whether proton magnetic resonance spectroscopy (MRS) could provide accurate information on histological grade and cell proliferation in astrocytomas. We studied 23 patients with astrocytomas: five grade II, 10 grade III and eight with grade IV (glioblastoma multiforme). We performed proton MRS and determined the Ki-67 labeling index (LI), a tumour proliferation marker, in the same areas of the astrocytomas, and examined the statistical relationship between proton MRS and Ki-67 LI. The N-acetylaspartate (NAA)/creatine-phosphocreatine (Cr) and NAA/choline (Cho)-containing compound ratios were always significantly lower and the Cho/Cr ratios significantly higher than those for normal brain. The Cho/Cr ratio correlated positively and the NAA/Cho ratio inversely with Ki-67 LI. These findings suggest that the Cho signal in proton MRS reflects cellular proliferation. In Kaplan-Meier survival analysis, there was no significant difference ...

2000-05-01

222

Monitoring of the insecticide trichlorfon by phosphorus-31 nuclear magnetic resonance ({sup 31}P NMR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Trichlorfon is an organophosphorus insecticide, which is extensively being used for protection of fruit crops. Trichlorfon is a thermal labile compound, which cannot be easily determined by gas chromatography (GC) and has no suitable group for sensitive detection by high performance liquid chromatography (HPLC). In this study, a {sup 31}P nuclear magnetic resonance ({sup 31}P NMR) has been described for monitoring of trichlorfon without any separation step. The quantitative works of {sup 31}P NMR spectroscopy has been performed in the presence of an internal standard (hexamethylphosphoramide). Limit of detection (LOD) for this method has been found to be 55 mg L{sup -1}, without any sample preparation, and the linear working range was 150-5500 mg L{sup -1}. Relative standard deviation (R.S.D.%) of the method for three replicates within and between days was obtained {<=}9%. The average recovery efficiency was approximately 99-112%. This ...

2006-08-25

223

Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)  

International Nuclear Information System (INIS)

Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...

224

Magnetic resonance imaging of the hip with a pelvic phased-array surface coil: a technical note  

Energy Technology Data Exchange (ETDEWEB)

Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer phased-array surface coils ...

1998-02-01

225

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular regurgitation was easy to differentiate from ...

226

Magnetic resonance appearance of peripheral nerve sheath tumors  

International Nuclear Information System (INIS)

Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship between the lesions and the adjacent neurovascular structures and ...

227

Low field magnetic resonance imaging of femoral neck fractures  

International Nuclear Information System (INIS)

Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).

228

Effect of external pH on the cytoplasmic and vacuolar pHs in Mung bean root-tip cells. A T P nuclear magnetic resonance study  

Energy Technology Data Exchange (ETDEWEB)

The effect of the external pH on the intracellular pH in mung bean (Vigna mungo (L.) Hepper) root-tip cells was investigated with the T P nuclear magnetic resonance (NMR) method. The T P NMR spectra showed three peaks caused by cytoplasmic G-6-P, cytoplasmic Psub(i) and vacuolar Psub(i). The cytoplasmic and vacuolar pHs could be determined by comparing the Psub(i) chemical shifts with the titration curve. When the external pH was changed over a range from pH 3 to 10, the cytoplasmic pH showed smaller changes than the vacuolar pH, suggesting that the former is regulated more strictly than the latter. The H -ATPase inhibitor, DCCD, caused the breakdown of the mechanism that regulates the intracellular pH. H -ATPase appears to have an important part in the regulation of the intracellular pH.

1984-12-01

229

Contrasting Kondo behavior and resonant inverse photoemission spectra of CeTSi{sub 3} and CeTGe{sub 3} (T=Rh and Ir)  

Energy Technology Data Exchange (ETDEWEB)

We have investigated CeTSi{sub 3} and CeTGe{sub 3} (T = Rh and Ir) by measuring the magnetic susceptibility, specific heat, electrical resistivity, the resonant inverse photoemission (RIPES) and M{sub IV,V} x-ray absorption spectra (XAS). The germanides showed a very weak Kondo effect, but the silicides exhibited a negatively large Weiss temperature (approx. = -130 K) and a lnT dependence of magnetic resistivity above 100 K, suggesting that they are a Kondo-lattice compound with a high Kondo temperature T{sub K} (approx. = 100 K). The Curie-Weiss law suggests that Ce atoms in these compounds remain close to 3+ down to about 150 K in spite of their high T{sub K}. In general, both RIPES and M{sub IV,V} XAS support their apparently stable valency. (author)

1999-02-28

230

A proton nuclear magnetic resonance investigation of the anion Bohr effect of human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution proton nuclear magnetic resonance spectroscopy has been used to investigate the molecular mechanism of the Bohr effect of human normal adult hemoglobin in the presence of two allosteric effectors, i.e., chloride and inorganic phosphate ions. The individual hydrogen ion equilibria of 22-26 histidyl residues of hemoglobin have been measured in anion-free 0.1 M HEPES buffer and in the presence of 0.18 M chloride or 0.1 M inorganic phosphate ions in both deoxy and carbonmonoxy forms. The results indicate that the #beta#2-histidyl residues are strong binding sites for chloride and inorganic phosphate ions in hemoglobin. The affinity of the #beta#2-histidyl residues for these anions is larger in the deoxy than in the carbonmonoxy form. Nevertheless, the contribution of these histidyl residues to the anion Bohr effect is small due to their low pK value in deoxyhemoglobin in anion-free solvents. The interactions of chloride and ...

231

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

232

Quantum Computing with an Electron Spin Ensemble  

DEFF Research Database (Denmark)

We propose to encode a register of quantum bits in different collective electron spin wave excitations in a solid medium. Coupling to spins is enabled by locating them in the vicinity of a superconducting transmission line cavity, and making use of their strong collective coupling to the quantized radiation field. The transformation between different spin waves is achieved by applying gradient magnetic fields across the sample, while a Cooper pair box, resonant with the cavity field, may be used to carry out one- and two-qubit gate operations.

2009-01-01

233

Pure NQR quantum computing  

Energy Technology Data Exchange (ETDEWEB)

It is shown that pure NQR can be utilized as a platform for quantum computing without applying a high external magnetic field. By exciting each resonance transition between quadrupole energy levels with two radio-frequency fields differing in phase and direction, the double degeneracy of the spin energy spectrum in an electric field gradient is removed. As an example, in the case of I=7/2 (nuclei {sup 133}Cs or {sup 123}Sb) the energy spectrum has eight levels which can be used as three qubits. (orig.)

2002-07-01

234

Preparation and Properties of New Ester-Linked Cleavable Gemini Surfactants  

British Library Electronic Table of Contents (United Kingdom)

We have prepared a series of novel gemini surfactants having ester bonds in their structures. These surfactants possess two identical hydrophilic polyethylene glycol moieties, two hydrophobic alkyl group moieties, and an anionic spacer. The structures of these compounds were confirmed through infrared and nuclear magnetic resonance spectroscopic and elemental analyses. The novel gemini surfactants exhibit excellent surface activity in terms of their surface tension, low-foaming, wetting power, and fluorescence properties. The presence of the ester linkages made these structures cleavable surfactants.

2011-01-01

235

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

236

Molecular accessibility in solvent swelled coal. Quarterly report  

Energy Technology Data Exchange (ETDEWEB)

To expand the information base on molecular accessibility in solvent swelled coal, Argonne Premium Coal Samples (APCS) were swelled in polar, basic solvents before and after moisture loss and upon air oxidation. So far studies have been reported on the changes in pore size distribution as a function of temperature when polar basic swelling solvents are used. Additional studies employing EPR spin probe techniques performed on the breaking up of the hydrogen bonding between bedding planes were later confirmed by magnetic resonance imaging at Argonne National Lab and the University of Illinois.

1992-11-01

237

Magnetic resonance imaging of the pediatric brain  

International Nuclear Information System (INIS)

The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.

238

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

239

IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT  

British Library Electronic Table of Contents (United Kingdom)

Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.

2011-01-01

240

Enriched lithium collection from lithium plasma flow  

International Nuclear Information System (INIS)

In order to understand the physical processes concerned with the selective heating by ion cyclotron resonance and with the subsequent collection of heated particles, experiments were carried out with the extraction of lithium samples, enriched with "6Li isotopes. Probe and integral extractors allow to collect enriched Li at the end of the selective heating region. Surface density distribution on the collector and local isotopic content of lithium are measured, as a function of the screen height and the retarding potential. Dependence of the collected amount of lithium and of its isotopic content on the value of the magnetic field is also measured. 4 figs., 2 tabs., 5 refs.

241

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

242

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

243

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.  

Science.gov (United States)

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737

2006-12-19

244

Menstrual variation of breast volume and T{sub 2} relaxation times in cyclical mastalgia  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Hormonal activity causes breast volume to change during the menstrual cycle. One possible cause of this volume change is thought to be due to water retention or oedema within the tissues. We used magnetic resonance imaging (MRI) to study the variation in breast volume and {sup 1}H Magnetic Resonance Spectroscopy (MRS) to measure T{sub 2} relaxation times which are known to increase with increasing tissue water content. We hypothesised that an increase in breast volume will elevate T{sub 2} relaxation due to the presence of an increased water content within the breast. T{sub 2} Relaxation time and volume were studied in fifteen control subjects and in a cohort of eight patients with cyclical mastalgia in order to determine whether changes in breast volume and T{sub 2} relaxation times differed in controls and patients during menses, ovulation and premenses. Method: Breast volume was determined ...

2008-02-15

245

"1H and "3"1P nuclear magnetic resonance investigation of the interaction between 2,3-diphosphoglycerate and human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution "1H and "3"1P nuclear magnetic resonance spectroscopy has been used to investigate the binding of 2,3-diphosphoglycerate to human normal adult hemoglobin and the molecular interactions involved in the allosteric effect of the 2,3-diphosphoglycerate molecule on hemoglobin. Individual hydrogen ion NMR titration curves have been obtained for 22-26 histidyl residues of hemoglobin and for each phosphate group of 2,3-diphosphoglycerate with hemoglobin in both the deoxy and carbonmonoxy forms. The results indicate that 2,3-diphosphoglycerate binds to deoxyhemoglobin at the central cavity between the two #beta# chains and the binding involves the #beta#2-histidyl residues. Moreover, the results suggest that the binding site of 2,3-diphosphoglycerate to carbonmonoxyhemoglobin contains the same (or at least some of the same) amino acid residues responsible for binding in the deoxy form. As a result of the specific interactions with ...

246

The Multipoles Factory An Element of the LHC Control  

CERN Document Server

The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the ...

2002-01-01

247

Optical and statistical model calculation of the americium 242m capture cross section  

International Nuclear Information System (INIS)

The capture cross sections of Am 242m can be deduced from resonances analysis at low energy and computed with theoretical models at high energy. In this work, a coherent set of cross sections which reproduced the experimental values of the fission cross sections is computed. These calculations were performed for an energy of the incoming neutron between 1 keV and 1 MeV.

248

Time-varying magnetic fields increase cytosolic free Ca sup 2+ in HL-60 cells  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic fields have been reported to cause a variety of biological effects. It has been hypothesized that many of these phenomena are mediated by a primary effect on the concentration of cytosolic free calcium ((Ca2+)i). We investigated the effects of exposure to electromagnetic fields on (Ca2+)i in HL-60 cells using the Ca2(+)-sensitive fluorescent indicator indo-1. Indo-1-loaded cell samples were exposed to a radiofrequency electromagnetic field, a static magnetic field, and a time-varying magnetic field, which were generated by a magnetic resonance imaging (MRI) unit. We found that a 23-min exposure to all three fields, in combination, induced a significant increase in (Ca2+)i of 31 +/- 8 (SE) nM (P less than 0.01, n = 13) from a basal level of 121 +/- 8 nM. Also, cells exposed to only the time-varying magnetic field had a mean (Ca2+)i that was 34 +/- 10 nM (P less than ...

1990-10-01

249

A MODEL OF THE SPECTRAL EVOLUTION OF PULSAR WIND NEBULAE  

International Nuclear Information System (INIS)

We study the spectral evolution of pulsar wind nebulae (PWNe) taking into account the energy injected when they are young. We model the evolution of the magnetic field inside a uniformly expanding PWN. Considering time-dependent injection from the pulsar and coolings by radiative and adiabatic losses, we solve the evolution of the particle distribution function. The model is calibrated by fitting the calculated spectrum to the observations of the Crab Nebula at an age of a thousand years. The spectral evolution of the Crab Nebula in our model shows that the flux ratio of TeV #gamma#-rays to X-rays increases with time, which implies that old PWNe are faint in X-rays, but not in TeV #gamma#-rays. The increase of this ratio is because the magnetic field decreases with time and is not because the X-ray emitting particles are cooled more rapidly than the TeV #gamma#-ray emitting ...

2010-06-01

250

COLLAPSE AND FRAGMENTATION OF MOLECULAR CLOUD CORES. X. MAGNETIC BRAKING OF PROLATE AND OBLATE CORES  

International Nuclear Information System (INIS)

The collapse and fragmentation of initially prolate and oblate, magnetic molecular clouds is calculated in three dimensions with a gravitational, radiative hydrodynamics code. The code includes magnetic field effects in an approximate manner: magnetic pressure, tension, braking, and ambipolar diffusion are all modeled. The parameters varied for both the initially prolate and oblate clouds are the initial degree of central concentration of the radial density profile, the initial angular velocity, and the efficiency of magnetic braking (represented by a factor f _m_b = 10"-"4 or 10"-"3). The oblate cores all collapse to form rings that might be susceptible to fragmentation into multiple systems. The outcome of the collapse of the prolate cores depends strongly on the initial density profile. Prolate cores with central densities 20 times higher than their boundary densities collapse ...

2009-06-01

251

Phenomenology of a light gluon resonance in top-physics at Tevatron and LHC  

CERN Document Server

We present a phenomenological analysis of the recent Tevatron results on the $t \\bar t$ forward-backward asymmetry and invariant-mass spectrum assuming a new contribution from an s-channel gluon resonance with a mass in the range from 700 to 2500 GeV. In contrast to most of the previous works, this analysis shows that for masses below ~1 TeV resonant New Physics could accommodate the experimental data. In general, we find that axial-like couplings are preferred for light and top quark couplings, and that only top quark couples strongly to New Physics. We find that composite model scenarios arise naturally from only phenomenological analyses of the experimental results. We show that our results are compatible with recent LHC limits in dijet and $t \\bar t$ production, and find some tension for large resonance mass ~2.5 TeV. We indicate as best observables for discriminating a relatively light new gluon ...

2011-01-01

252

Average neutron resonance parameters and radiative capture cross sections for the isotopes of molybdenum  

International Nuclear Information System (INIS)

The neutron capture cross sections of the stable molybdenum isotopes have been measured with high energy resolution (#DELTA#E/E < approximately 0.2%), between 3 and 90 keV neutron energy, at the 40 m station of ORELA. Average resonance parameters are extracted for s- and p-wave resonances. The s-wave neutron strength function is close to 0.5x10"-"4 for all isotopes, but the p-wave strength function exhibits a well defined peak near A approximately 95. Both s- and p-wave radiative widths decrease markedly as further neutrons are added to the closed shell. The p-wave radiative widths are generally greater than the s-wave widths showing the presence of non-statistical #gamma#-decay mechanisms. Valence neutron theory fails to explain the magnitude of the p- to s-wave radiative width disparity and doorway state processes are invoked. In particular, the data for "9"8Mo appear to violate the usual valence theory, since the correlations between ...

253

Absorption Features in Spectra of Magnetized Neutron Stars  

CERN Document Server

The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the ...

2010-01-01

254

Horizontal vibration suppression method suitable for super-high-speed elevators; Chokosoku elevator ni tekishita kago yokoshindo yokusei hoshiki  

Energy Technology Data Exchange (ETDEWEB)

Horizontal vibrations of elevator cars mainly occur because a car swings as roller guides installed at corners of a car frame move on a winding guide rail at high speeds. Rider comfort in high speed elevators is worsened by these vibrations. Conventional active dampers suppressing horizontal vibrations using ac servo motors make cars heavier so driving power becomes larger, and they are not easily applied to existing elevators. An active damping control method suited to super-high-speed elevators is which can solve these problems. The method suppresses vibrations by generating only enough magnetic force needed to suppress them only when vibrations of the car franc are produced. The vibrations are detected using acceleration detectors and magnets installed on left and right sides of the car frame. A computer simulator was made to analyze phenomena of car vibrations and to verify effects of the proposed magnetic damping ...

1998-03-01

255

T{sub 1} and T{sub 2} relaxivities of succimer-coated MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

Energy Technology Data Exchange (ETDEWEB)

Superparamagnetic MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r{sub 2}/r{sub 1}, for MnFe{sub 2}O{sub 4}, Fe{sub 3}O{sub 4} and CoFe{sub 2}O{sub 4} were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T{sub 2} contrast agents for MRI.

2009-12-15

256

T1 and T2 relaxivities of succimer-coated MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

International Nuclear Information System (INIS)

Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.

2009-12-01

257

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

258

Remodeling of the free electron laser with the L-band linac at Osaka University  

International Nuclear Information System (INIS)

The far infrared free electron laser (FEL) has been being developed since 1990 using the L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. The first lasing was obtained in 1994 at wavelengths from 32 to 40 #mu#m. The FEL is now being modified suitable for user experiments. The wiggler with a fixed magnet gap used in the original FEL has been remodeled to make the magnet gap variable. In order to optimize the variable range of the gap, the gain and the diffraction loss were calculated. The peak gain is calculated to be 270% and the diffraction loss to be 22% at 150 #mu#m. The wavelength is expected to be variable from 25 up to at least 150 #mu#m. The two bending magnets in the optical resonator have been remodeled and the vacuum chambers with larger vertical sizes for them have been newly made so that the diffraction loss in these parts becomes smaller than ...

1997-02-28

259

Radio Frequency Plasma Applications for Space Propulsion  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ...

1999-09-13

260

High Voltage Measurements on Nine PFNs for the LHC Injection Kicker Systems  

CERN Document Server

Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions and measurements are ...

2005-01-01

261

Quasienergy description of the driven Jaynes-Cummings model  

CERN Document Server

We analyze the driven resonantly coupled Jaynes-Cummings model in terms of a quasienergy approach by switching to a frame rotating with the external modulation frequency and by using the dressed atom picture. A quasienergy surface in phase space emerges whose level spacing is governed by a rescaled effective Planck constant. Moreover, the well-known multiphoton transitions can be reinterpreted as resonant tunneling transitions from the local maximum of the quasienergy surface. Most importantly, the driving defines a quasienergy well which is nonperturbative in nature. The quantum mechanical quasienergy state localized at its bottom is squeezed. In the Purcell limited regime, the potential well is metastable and the effective local temperature close to its minimum is uniquely determined by the squeezing factor. The activation occurs in this case via dressed spin flip transitions rather than via quantum activation as in other ...

2010-01-01

262

Chaos and bifurcation control of SSR in the IEEE second benchmark model  

International Nuclear Information System (INIS)

Linear and nonlinear state feedback controllers are proposed to control the bifurcation of a phenomenon in power system, this phenomenon of electro-mechanical interaction between the series resonant circuits and torsional mechanical frequencies of the turbine-generator sections, which known as subsynchronous resonance (SSR). The first system of the IEEE second benchmark model is considered. The dynamics of the two axes damper windings, automatic voltage regulator and power system stabilizer are included. The linear controller gives better initial disturbance response than that of the nonlinear, but in a small narrow region of compensation factors. The nonlinear controller not only can be easily implemented, but also it stabilizes the operating point for all values of the bifurcation parameter.

2004-07-01

263

Tidal spin-up and magnetic braking in cataclysmic variables  

International Nuclear Information System (INIS)

Based on proposed models for the tidal spin-up and magnetic braking of stars with a convective outer envelope, it is suggested that the rotation of secondaries in cataclysmic variables is not necessarily synchronized with the orbital revolution. This may provide an explanation for the observed large range in the mass transfer rate (at the same orbital period) of cataclysmic variables above the period gap. (author).

264

One-dimensional numerical simulation of free-electron laser (FEL) amplifier with incorporate variable-parameter wiggler magnets  

International Nuclear Information System (INIS)

A physical model of free-electron laser (FEL) amplifier with variable-parameter wiggler magnets for one-dimensional numerical simulation is presented and a numerical example is given. The wiggler parameters, efficiency of energy conversion between electron beam and laser field, laser intensity, phase-space distributions and energy spectrum of electrons are computed. The period of synchronous oscillation and saturation value of laser intensity agree with estimated one.

265

Nanocrystalline materials: Interfaces and mesoscopic correlations studied by neutron scattering  

International Nuclear Information System (INIS)

Nanocrystalline materials can exhibit properties which are considerably different from their coarse-grained counterparts, making them unique for basic or applied research and also very promising for potential applications. The topics which are addressed in the present paper are magnetic properties and magnetic correlations on the nanometer scale, mechanical properties, in particular the influence of grain boundaries on the elastic and plastic behaviour, and vibration models of grain boundary atoms in nanostructured materials. (author)

2001-09-23

266

Magnetoresistance of Two-Dimensional Tight-Binding Electrons in a Weak Magnetic Field  

International Nuclear Information System (INIS)

We study the Anderson model on a two-dimensional square lattice with an applied weak magnetic field B which causes the hopping matrix elements to have Peierls phase factors. The recursion method is applied and B dependent conductivity ?(B) is calculated from the Kubo formula for different system sizes and degree of disorder W . For large W there is no systematic change of ?(B) with B, it shows a fluctuating behavior.

2008-08-25

267

Isospin-symmetry breaking effects on the strange electric and magnetic form factors of the nucleon  

Science.gov (United States)

We examine the electric and magnetic strange form factors of the nucleon in the pseudoscalar-vector SU(3) Skyrme model, with special emphasis on the effects of isospin symmetry breaking (ISB). It is found that ISB has a nontrivial effect on the strange vector form factors of the nucleon and its contribution to the nucleon strangeness is significantly larger than one might naively expect. Our calculations and discussions may be of some significance for the experimental extraction of the authentic strangeness.

2008-07-15

268

Isospin-symmetry breaking effects on the strange electric and magnetic form factors of the nucleon  

International Nuclear Information System (INIS)

We examine the electric and magnetic strange form factors of the nucleon in the pseudoscalar-vector SU(3) Skyrme model, with special emphasis on the effects of isospin symmetry breaking (ISB). It is found that ISB has a nontrivial effect on the strange vector form factors of the nucleon and its contribution to the nucleon strangeness is significantly larger than one might naively expect. Our calculations and discussions may be of some significance for the experimental extraction of the authentic strangeness.

2008-07-01

269

Indirect evidence for the existence of tachyons; a unified approach to the pion #-># muon #-># electron conversion problem  

International Nuclear Information System (INIS)

Using the experimentally determined cutoff energies of the muon-electron and the pion-electron conversion curves in a tachyon-bradyon model of the electron and the muon, the magnetic moments of these particles have been derived and found to be the Bohr magnetons identically. The tachyons, being bound to the bradyons and unable to drop below the speed of light, cause the bradyons to revolve in an orbit. It is this orbital motion of the charged bradyons that generates the magnetic moments.

270

Propagation of pressure perturbations in bubbly air/water flows  

Energy Technology Data Exchange (ETDEWEB)

The propagation of acoustic pressure perturbations in an adiabatic low-quality air/water flow were investigated both theoretically and experimentally. A linearized dispersion model is correlated with data to extract information on the behavior of interfacial momentum transfer controlled by the virtual volume coefficient. The dispersion model is examined in limiting cases of low and high frequency and related to current models for critical flow velocity. Fourier decomposition techniques are employed to predict the dispersion of measured pressure pulses and to relate data for standing waves and propagating pulses. The dispersion model is based on a two-fluid model and is the most complete model available in the literature at this time. The dispersion data presented herein is also the best available to date for low frequency (i.e., frequencies less than bubble ...

1987-01-01

271

Electron density and collision frequency of microwave resonant cavity produced discharges. [Progress report  

Energy Technology Data Exchange (ETDEWEB)

This progress report consists of an article, the abstract of which follows, and apparently the references and vita from a proposal. A review of perturbation diagnostics applied to microwave resonant cavity discharges is presented. The classical microwave perturbation technique examines the shift in the resonant frequency and cavity quality factor of the resonant cavity caused by low electron density discharges. However, modifications presented here allow the analysis to be applied to discharges with electron densities beyond the limit predicted by perturbation theory. An {open_quote}exact{close_quote} perturbation analysis is presented which models the discharge as a separate dielectric, thereby removing the restrictions on electron density imposed by the classical technique. The {open_quote}exact{close_quote} method also uses measurements of the shifts in the resonant conditions of ...

1992-12-31

272

Pituitary disease in childhood: utility of magnetic resonance; Patologia hipofisaria en la edad pediatrica: unidad de la resonance magnetica  

Energy Technology Data Exchange (ETDEWEB)

To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children with ...

2000-07-01

273

Tuning the spin state of iron phthalocyanine by ligand adsorption  

International Nuclear Information System (INIS)

The future use of single-molecule magnets in applications will require the ability to control and manipulate the spin state and magnetization of the magnets by external means. There are different approaches to this control, one being the modification of the magnets by adsorption of small ligand molecules. In this paper we use iron phthalocyanine supported by an Au(111) surface as a model compound and demonstrate, using x-ray photoelectron spectroscopy and density functional theory, that the spin state of the molecule can be tuned to different values (S #approx# 0, 1/2, 1) by adsorption of ammonia, pyridine, carbon monoxide or nitric oxide on the iron ion. The interaction also leads to electronic decoupling of the iron phthalocyanine from the Au(111) support. (fast track communication)

2010-12-01

274

Spin-polarized Auger-electron diffraction study of the magnetic poisoning of Fe(001) by sulfur  

International Nuclear Information System (INIS)

Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.

275

Numerical modeling of a MEMS actuator considering several magnetic force calculation methods  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The purpose of this paper is to investigate the accuracy of different force calculation methods and their impact on mechanical deformations. For this purpose, a micrometer scaled actuator is considered, which consists of a micro-coil and of a permanent magnet (PM) embedded in a deformable elastomeric layer. Design/methodology/approach - For the magnetic field evaluation a hybrid numerical approach (finite element method/boundary element method (FEM/BEM) coupling and a FEM/BEM/Biot-Savart approach) is used, whereas FEM is implemented for the mechanical deformation analysis. Furthermore, for the magneto-mechanical coupling several force calculation methods, namely the Maxwell stress tensor, the virtual work approach and the equivalent magnetic sources methods, are considered and co...

2011-01-01

276

Magnetism of DyPd_2Si_2 and ErPd_2Si_2  

International Nuclear Information System (INIS)

Neutron diffraction and magnetometric measurements on polycrystalline samples of DyPd_2Si_2 and ErPd_2Si_2 were carried out in the temperature range from 2 to 293 K. Both compounds show tetragonal ThCr_2Si_2 type crystal structure and order at 12 K in a sine modulated magnetic structure with propagation vectors k=[0.609,0,0.155] and [0.575, 0, 0.083] respectively. The oscillatory character of magnetic order found in RPd_2Si_2 (R=Tb-Er) compounds suggests exchange interaction described by the RKKY model to be dominant, but the non-monotonic dependence of respective Neel temperatures on the number of f-electrons indicates the influence of a crystalline electric field (CEF) on the magnetic behaviour in this series. (orig.).

277

Magnetic properties of ErPd_2Si_2 from magnetization Moessbauer and neutron diffraction measurements  

International Nuclear Information System (INIS)

Magnetization, neutron diffraction and "1"6"6Er Moessbauer measurements on ErPd_2Si_2 are reported. Below 4.8 K ErPd_2Si_2 orders AF with complex modulated magnetic structures, where the Er moments are aligned along the c-axis. At 1.5 K a squared structure with #mu#_E_r #approx# 7.8(1)#mu#_B is found while a saturation Er moment of 8.2(2)#mu#_B is inferred from the hyperfine field data. The temperature dependence of the Moessbauer spectra in the paramagnetic region is explained in the framework of a relaxation model implying excited crystal field levels. Its analysis is used to estimate the B"m_n CEF parameters. (orig.).

278

Development of magnet power supply for J-PARC 50-GEV synchrotron  

International Nuclear Information System (INIS)

A new magnet power supply system for J-PARC 50GeV Synchrotron is proposed as solutions both in the power capacity and in the precision at the same time. The developed 10MW class magnet power supply consists of the advanced self-commutated current-source type converter (ACSC) using the new device IEGT rated at 4500V-2100A and the ''hybrid filter'' including the variable impedance filter with the equivalent 16 kHz switching. With 1/16 scale-model system using a prototype bending magnet, the experimental results showed the current ripple less than 1 x 10"-"6 and the tracking error less than #+-#0.5 x 10"-"4. (author)

2004-08-04

279

DFT study of structure?properties correlations in [MnTPP][TCNE] quasi-one-dimensional molecular magnets  

British Library Electronic Table of Contents (United Kingdom)

We report the first band structure calculations of the quasi-one-dimensional [MnTPP][TCNE] compounds (TPP?=?meso-tetraphenylporphyrinato, TCNE?=?tetracyanoethylene), based on Density Functional Theory (DFT) methods, in order to interpret the magnetic ordering in these prototypic systems. We compare and contrast the results of broken-symmetry DFT calculations for extended systems, with periodic boundary conditions, and for finite systems, magnetic dimers modeling the actual molecular magnets. By varying systematically the main angles, we are able to determine the geometry dependence of the exchange interaction. Structure?properties correlations in these charge-transfer salts reveal the determinant role of the Mn-(N?C)TCNE bond angle on the strength of the ferrimagnetic coupling between the ...

2011-01-01

280

Electron Flux - 8.0 keV - ISWA wiki - ISWA - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

281

Electron Flux - 4.7 keV - ISWA wiki - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

282

Electron Flux - 179 keV - ISWA wiki - ISWA - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

283

Algebraic analysis of the electromagnetic wave interaction with the two-level system with two-fold degenerated states  

Energy Technology Data Exchange (ETDEWEB)

Algebraic properties of the analytical model, describing electro-magnetic weak interaction with the two-level system with two-fold degenerate state are considered. The expressions for the coherent states and Green function of the system are obtained.

1989-04-20

284

Validation of the GROMOS force-field parameter set 45A3 against nuclear magnetic resonance data of hen egg lysozyme  

Energy Technology Data Exchange (ETDEWEB)

The quality of molecular dynamics (MD) simulations of proteins depends critically on the biomolecular force field that is used. Such force fields are defined by force-field parameter sets, which are generally determined and improved through calibration of properties of small molecules against experimental or theoretical data. By application to large molecules such as proteins, a new force-field parameter set can be validated. We report two 3.5 ns molecular dynamics simulations of hen egg white lysozyme in water applying the widely used GROMOS force-field parameter set 43A1 and a new set 45A3. The two MD ensembles are evaluated against NMR spectroscopic data NOE atom-atom distance bounds, {sup 3}J{sub NH{alpha}} and {sup 3}J{sub {alpha}}{sub {beta}} coupling constants, and {sup 1}5N relaxation data. It is shown that the two sets reproduce structural properties about equally well. The 45A3 ensemble fulfills the atom-atom distance bounds derived from NMR spectroscopy slightly less well ...

2004-12-15

286

2D modeling and preliminary in vitro investigation of a prototype high gradient magnetic separator for biomedical applications.  

Science.gov (United States)

High gradient magnetic separation (HGMS) of magnetic materials from fluids or waste products has many established industrial applications. However, there is currently no technology employing HGMS for ex-vivo biomedical applications, such as for the removal of magnetic drug- or toxin-loaded spheres from the human blood stream. Importantly, human HGMS applications require special design modifications as, in contrast to conventional use where magnetic elements are permanently imbedded within the separation chambers, medical separators need to avoid direct contact between the magnetic materials and blood to reduce the risk of blood clotting and to facilitate convenient and safe treatment access for many individuals. We describe and investigate the performance of a magnetic separator prototype designed for biomedical applications. First, the capture efficiency of a ...

2007-03-30

287

Summary of the report of the Senior Committee on Environmental, Safety, and Economic Aspects of Magnetic Fusion Energy  

Energy Technology Data Exchange (ETDEWEB)

The Senior Committee on Environmental, Safety, and Economic Aspects of Magnetic Fusion Energy (ESECOM) has assessed magnetic fusion energy's prospects for providing energy with economic, environmental, and safety characteristics that would be attractive compared with other energy sources (mainly fission) available in the year 2015 and beyond. ESECOM gives particular attention to the interaction of environmental, safety, and economic characteristics of a variety of magnetic fusion reactors, and compares them with a variety of fission cases. Eight fusion cases, two fusion-fission hybrid cases, and four fission cases are examined, using consistent economic and safety models. These models permit exploration of the environmental, safety, and economic potential of fusion concepts using a wide range of possible materials choices, power densities, power conversion schemes, and fuel ...

1987-09-10

288

Spin correlations in the frustrated square lattice Pb{sub 2}VO(PO{sub 4}){sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The new frustrated square-lattice system, Pb{sub 2}VO(PO{sub 4}){sub 2}, has been investigated using polarised neutron scattering. From these studies, made on powdered samples, we have determined the nature of the exchange interactions and the magnetic ordering for this novel quantum magnet. Quantum order from disorder occurs at low temperature, and the ground state observed below the Neel temperature T {sub N}{approx}3.7 K is a collinear antiferromagnet. At room temperature there are no magnetic correlations and it is possible to model the scattering with the V{sup 4+} magnetic form factor. However, at T{approx}20 K, a temperature well into the paramagnetic phase, magnetic correlations are observed, and these spin correlations have been modelled using a high-temperature series expansion. Ferromagnetic nearest-neighbour exchange J {sub ...

2007-03-15

289

Magnetic field amplification and generation in hypervelocity meteoroid impacts with application to lunar paleomagnetism  

International Nuclear Information System (INIS)

A one-dimensional numerical model for the expansion of impact-produced vapor clouds is used to investigate magnetic field generation mechanisms in events such as meteor collisions with the moon. The resulting cloud properties, such as ionization fraction, electrical conductivity, radial expansion velocity, mass density, and energy density are estimated. The model is initiated with the peak shock states and pressure thresholds for incipient and complete vaporization of anorthosite lunar surface materials by iron and GA composition meteorites. The expansion of the spherical gas cloud into a vacuum was traced with a one-dimensional explicit lagrangian hydrodynamic code. The hypervelocity impact plasmas produced are found to be significant in the amplitudes and orientations of the magnetic fields generated. An ambient magnetic field could have been provided by the core dynamo, which ...

1984-03-12

290

Physical basis of the effect of hemoglobin on the "3"1P NMR chemical shifts of various phosphoryl compounds  

International Nuclear Information System (INIS)

The marked difference between the intra- and extracellular "3"1P NMR chemical shifts of various phosphoryl compounds when added to a red cell suspension may be largely understood in terms of the effects of hemoglobin on the "3"1P NMR chemical shifts. The presence of [oxy- or (carbonmonoxy)-] hemoglobin inside the red cell causes the bulk magnetic susceptibility of the cell cytoplasm to be significantly less than that of the external solution. This difference is sufficient to account for the difference in the intra- and extracellular chemical shifts of the two phosphate esters trimethyl phosphate and triethyl phosphate. However, in the case of the compounds dimethyl methylphosphonate, diethyl methylphosphonate, and trimethylphosphine oxide as well as the hypophosphite, phenylphosphinate, and diphenylphosphinate ions, hemoglobin exerts an additional, much larger, effect, causing the "3"1P NMR resonances to shift to lower frequency in a manner ...

291

On the disrupted magnetic braking model for the period gap of cataclysmic variables  

International Nuclear Information System (INIS)

The disrupted magnetic braking theory for the period gap of cataclysmic variable systems is used to study the binary evolution of low-mass main-sequence-like stars with white dwarf companions. The model is able to reproduce the observed location and width of the gap provided that the average mass transfer rates above the upper edge of the gap are greater than about 1.9 x 10 to the -9th solar masses/yr. For the case of angular momentum loss by magnetic braking, the slope of the mass transfer rate with respect to orbital period is shown to range from 3.4 to 3.7. For the evolutionary sequences considered, the He-3 abundance at the surface of the secondary exceeds 0.0015 after the complete mixing phase, resulting in modifications in the nuclear burning development of nova explosions. 31 refs.

292

Investigation of the magnetic field response from eddy current inspection of defects  

British Library Electronic Table of Contents (United Kingdom)

Eddy current testing is one of the most widely used methods in non-destructive testing for the inspection of conductive materials. Numerical modelling of eddy current testing has emerged as an important approach alongside experimental studies. This paper investigates an application of numerical modelling and experimental study as a means of the quantitative non-destructive evaluation (QNDE) of defects in conductive samples. There are two methods of measuring eddy current response, more commonly by measuring the change in impedance of the eddy current probe coil, or as used in this work, by measuring the change in magnetic field directly using magnetic field sensors such as superconducting quantum interference devices, giant magneto resistance, or as in this case Hall sensors. Specifically,...

2011-01-01

293

Field-induced valence transition of Eu(Pd_1_-_xPt_x)_2Si_2  

International Nuclear Information System (INIS)

The magnetic susceptibility and high-field magnetization have been measured for the intermediate valence system Eu(Pd_1_-_xPt_x)_2Si_2 with 0#<=#x#<=#0.15. A first-order valence transition is observed for all the compounds under high field of 100 T at low temperatures. This valence transition is of first order accompanied with a large hysteresis, which is in contrast to a continuous valence change against temperature. Based on the interconfigurational fluctuation (ICF) model, the temperature- and field-induced valence transitions are discussed. It is found that a first-order valence transition can be induced by magnetic field, even if the system shows a continuous valence transition against temperature. Metamagnetic behavior at finite temperatures is also understood qualitatively by the ICF model. copyright 1997 The American Physical Society.

294

Structure functions at low Q^2: higher twists and target mass effects  

Energy Technology Data Exchange (ETDEWEB)

We review the physics of structure functions at low Q{sup 2}, focusing on the phenomenon of quark-hadron duality and the resonance-scaling transition, both phenomenologically and in the context of quark models. We also present a new implementation of target mass corrections to nucleon structure functions which, unlike existing treatments, has the correct kinematic threshold behavior at finite Q{sup 2} in the x -> 1 limit.

2006-05-22

295

Realistic level density calculation for heavy nuclei  

Energy Technology Data Exchange (ETDEWEB)

A microscopic calculation of the level density is performed, based on a combinatorial evaluation using a realistic single-particle level scheme. This calculation relies on a fast Monte Carlo algorithm, allowing to consider heavy nuclei (i.e., large shell model spaces) which could not be treated previously in combinatorial approaches. An exhaustive comparison of the predicted neutron s-wave resonance spacings with experimental data for a wide range of nuclei is presented.

1994-12-31

296

Quark-parton picture of the cumulative production  

International Nuclear Information System (INIS)

The quark structure of constituent nucleons is considered by a qualitative comparison of features of different models with experimental data with respect to cumulative meson production. It is shown that the fluctuation of the density of nuclear matter, ie the creation and disintegration of a short lived few-nucleon correlation (flucton), is a type of the quasi-resonance formation in the nucleus which exists without any connection with the incident particle. The cumulative production in the region under investigation is mostly the result of a Regge type dissociation of the flucton. (U.K.).

297

Production of MSSM Higgs bosons in photon-photon collisions  

International Nuclear Information System (INIS)

The heavy neutral Higgs bosons H, A in the minimal supersymmetric extension of the standard model can be produced as single resonances at high-energy #gamma##gamma# colliders. We have studied the prospects of the search for these particles in bb and neutralino-pair final states. The Higgs bosons can be found with masses up to 70-80% of the initial e"#+-#e"- collider energy for medium values of tg#beta#, i.e. in areas of the supersymmetric parameter space not accessible at other colliders. (orig.)

298

Production of MSSM Higgs bosons in #gamma##gamma# collisions  

International Nuclear Information System (INIS)

The heavy Higgs bosons H,A of the minimal supersymmetric extension of the Standard Model can be produced as resonances in high-energy #gamma##gamma# colliders. Prospects of the search for these particles in bb-bar and neutralino-pair final states are studied in this report. Heavy Higgs bosons can be found with masses up to about 70-80% of the initial e"+e"- collider energy for moderate values of tan #beta#, i.e. in areas of the parameter space not accessible at other colliders.

2001-10-11

299

Pion-nucleon charge exchange amplitudes above 2 GeV  

Energy Technology Data Exchange (ETDEWEB)

The amplitudes for the pion-nucleon charge exchange reaction of the Karlsruhe-Helsinki and the George-Washington-University partial-wave analyses are compared with those of a Regge-cut model with the aim to explore the possibility to provide high-energy constraints for theoretical baryon resonance analyses in the energy region above 2 GeV. (orig.)

2009-04-15

300

EXCITATION OF ISOBARIC ANALOG STATES IN $sup 89$Y AND $sup 90$Zr  

Science.gov (United States)

The excitation of compound-nucleus resonances in Y/sup 89/ and Zr/sup 90/ by proton bombardment at 4 to 5.5 Mev of Sr/sup 88/ and Y/sup 89/, respectively, is reported. Shell-model corfigurations were used to interpret the results. (R.E.U.)

1964-02-24

301

Final technical report for ''Frontiers in Plasma Kinetic Theory''  

International Nuclear Information System (INIS)

This report summarizes the results and activities funded by this three-year award. The principal goal of this project was to determine the thermal conductivity in clusters of galaxies. Intracluster plasmas possess chaotic magnetic fields. Since charged particles are constrained to move primarily along magnetic field lines, the topology of intracluster magnetic fields slows particle diffusion relative to the non-magnetized case, thereby reducing the thermal conductivity. Our first approach to this problem was to employ the static-magnetic-field approximation. In reality, intracluster magnetic field lines are constantly moving, since they are advected by turbulent intracluster motions. The turbulent velocities, however, are much smaller than the rapid speeds of thermal electrons, which make the dominant contribution to the thermal conductivity. In the static-field ...

2007-02-01

302

Nuclear magnetic resonance spectroscopy in the structure elucidation and biosynthesis of natural products  

Energy Technology Data Exchange (ETDEWEB)

Examination of a chloroform extract of Dracaena loureiri Gagnep (Agavaceae), a Thia medicinal plant possessing antibacterial activity, has led to the isolation of fifteen flavenoids. The biogenic relationships among these flavenoids isolated were briefly discussed. Definition of the skeleton and the unambiguous assignment of all of the protons of the isolates was achieved through extensive 2D-homonuclear chemical shift correlation, nuclear Overhauser effect (NOE) difference spectroscopy and 2D-NOE experiments. The {sup 1}H and {sup 13}C NMR spectra of staurosporine, a potent biologically active agent from Streptomyces staurosporeus, were unambiguously assigned by using 2D homonuclear chemical shift correlation, NOE, {sup 1}H-detected heteronuclear multiple-quantum coherence via direct coupling and via multiple-bond coupling for resonance assignments of protonated and nonprotonated carbons, respectively. S. Staurosporeus was found to utilize endogenous and exogenous ...

1988-01-01

303

Free electron laser  

International Nuclear Information System (INIS)

The present article outlines major features of the free electron laser (FEL) and reviews research and development of FEL. Relations among the oscillation frequency, electron beam parameters and wiggler parameters, the physical mechanism of amplification and the physical process of saturation are discussed to identify the difference between FEL and other lasers. The report also outlines techniques for accelerators which are used to generate high-quality, high-energy electron beams required for FEL experiments. Techniques to achieve a short wavelength, high output and high efficiency, and applications of FEL are also discussed. FEL consists of an electron accelerator, wiggler and optical resonator. In FEL, electron beams with a relativistic energy interact resonantly with an electromagnetic field to generate coherent electromagnetic waves. Unlike conventional lasers, FEL does not surfer from restrictions on its oscillation frequency associated ...

304

Magnetism of the Ni(110) and Ni(100) surfaces: local-spin-density-functional calculations using the thin-slab linearized augmented-plane-wave method  

International Nuclear Information System (INIS)

Results of self-consistent local-spin-density-functional calculations are reported for the first time for the Ni(110) surface, represented by one-, three-, and five-layer slabs. Calculations for one- and five-layer slabs of Ni(100) are also reported. The behavior of the surface magnetization with varying slab thickness elucidates the nature and origin of the surface magnetic moment. We predict a 13% enhancement of the Ni(110) surface magnetic moment compared to the bulk value. For the Ni(100) surface, we find a smaller surface enhancement about 7%, compared to bulk, which agrees with the results of Jepsen et al. The enhancement of surface magnetic moments on Ni(100) and Ni(110) surfaces is attributed to s-d dehybridization at the surface and to the presence of electrostatic shifts required to maintain layer-by-layer charge neutrality. We find that the total d-electron charge is the same in each layer, ...

305

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission ...

2000-12-01

306

Analysis of the requirements for economic magnetic fusion  

Energy Technology Data Exchange (ETDEWEB)

A generic reactor model is used to examine the economic viability of electricity generation by magnetic fusion. The simple model uses components which are representative of those used in previous reactor studies of deuterium-tritium burning tokamaks, stellarators, bumpy tori, reverse field pinches and tandem mirrors. Conservative costing assumptions are made. The generic reactor is not a tokamak but rather it is intended to emphasize what is common to all magnetic fusion reactors. The reactor uses a superconducting toroidal coil set to produce the dominant magnetic field. To this extent it is a less good approximation to systems, such as the reversed field pinch in which the main field is produced by a plasma current. The main output of the study is the cost of electricity as a function of the weight and size of the fusion core - blanket, shield, structure and coils. The ...

1986-01-01

307

Effects of the alfven wave spectrum in heating experiments in TCA  

International Nuclear Information System (INIS)

Reduction of the metallic impurity concentration in the TCA plasma has enabled us to correlate the observed heating with the calculated position where the rf energy is deposited. In modelling the measured antenna loading due to the presence of Alfven resonance surfaces, and hence inferring the energy deposition profile, both ion cyclotron effects and the toroidal geometry must be considered. In particular, toroidicity couples energy to resonance surfaces that would not be excited in cylindrical geometry. The increase in electron density during a rf pulse changes the positions of these surfaces so that spectrum-related effects may be observed. The appearance of a new surface at the centre of the plasma is seen as a sharp discontinuity on many of the macroscopic parameters, accompanied by evidence of changes in the current density profile. These results, and the predictions of numerical codes, have imposed new constraints on ...

308

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Energy Technology Data Exchange (ETDEWEB)

The dynamic response characteristics of the VAWT rotor are important factors governing the safety and fatique life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and Coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. This paper will describe and discuss the primary tools now in use at Sandia National Laboratories for rotor analysis. These tools include a lumped spring-mass model (VAWTDYN) and also finite-element based approaches. The discussion will center on the accuracy and completeness of current capabilities and plans for future research. As this paper is meant primarily to provide an overview, much of the detail is omitted and will be presented in a follow-on report.

1981-05-01

309

An analytical study on excitation of nuclear-coupled thermal hydraulic instability due to seismically induced resonance in BWR  

Energy Technology Data Exchange (ETDEWEB)

A core-wide in-phase neutron flux oscillation, which took place, for example, at LaSalle-2 in the USA in 1988, is one of the nuclear-coupled thermal hydraulic instabilities in boiling water reactors (BWRs). In this study, an analysis has been performed focusing on the excitation of this type of instability in BWRs due to seismically induced resonance, within the scope of a point kinetics model. For this purpose, the TRAC-BF1 code has been modified to take into account the external acceleration in addition to gravity. As a result of this analysis, it is shown that reactivity insertion can occur accompanied by in-surge of the coolant into the core resulting from excitation. It is also shown that the amount of reactivity inserted largely depends on the degree of stability of the initial state and the amplitude of the seismic wave, whose frequency is the same as the characteristic frequency of the instability. (orig.).

1996-04-01

310

An analytical study on excitation of nuclear-coupled thermal hydraulic instability due to seismically induced resonance in BWR  

International Nuclear Information System (INIS)

A core-wide in-phase neutron flux oscillation, which took place, for example, at LaSalle-2 in the USA in 1988, is one of the nuclear-coupled thermal hydraulic instabilities in boiling water reactors (BWRs). In this study, an analysis has been performed focusing on the excitation of this type of instability in BWRs due to seismically induced resonance, within the scope of a point kinetics model. For this purpose, the TRAC-BF1 code has been modified to take into account the external acceleration in addition to gravity. As a result of this analysis, it is shown that reactivity insertion can occur accompanied by in-surge of the coolant into the core resulting from excitation. It is also shown that the amount of reactivity inserted largely depends on the degree of stability of the initial state and the amplitude of the seismic wave, whose frequency is the same as the characteristic frequency of the instability. (orig.).

1996-01-01

311

Theoretical investigation of the behavior of an acoustic metamaterial with extreme Young's modulus  

British Library Electronic Table of Contents (United Kingdom)

A mechanical model with local resonators is proposed as an acoustic metamaterial that exhibits an unusual frequency-dependent effective stiffness. If treated as an equivalent elastic solid, its effective Young's modulus can become unbounded or vanishingly small at two respective frequencies. Moreover, in a certain frequency range, the effective Young's modulus would become negative, resulting in a band gap that coincides with this frequency range. The wave attenuation behavior and mechanism are studied through numerical simulations on the acoustic metamaterial model. The capability of the metamaterial to selectively block or filter unwanted waves is demonstrated by a numerical simulation example.

2011-01-01

312

Singlet scalars as Higgs imposters at the Large Hadron Collider  

CERN Document Server

An electroweak singlet scalar can couple to pairs of vector bosons through loop-induced dimension five operators. Compared to a Standard Model Higgs boson, the singlet decay widths in the diphotons and Z gamma channels are generically enhanced, while decays into massive final states like WW and ZZ are kinematically disfavored. The overall event rates into gamma gamma and Z gamma can exceed the Standard Model expectations by orders of magnitude. Such a singlet may appear as a resonant signal in the gamma gamma and Z gamma channels, even with a mass above the WW kinematic threshold.

2011-01-01

313

Quasi-landau resonances: analytic treatment of the hydrogenic spectrum in the two-dimensional model and relation to other strong-field problems  

Energy Technology Data Exchange (ETDEWEB)

The two-dimensional WKB model has been the basis for several investigations of the quasi-Landau hydrogenic spectrum. Whereas other authors have used numerical integration, it is shown that the results can be obtained analytically in terms of elliptic integrals. The later are easily generated by even programmable pocket calculators, from which numerical results - which are in good agreement with experiments - are easily obtained. A further advantage of using elliptic integrals is that several strong-field problems can be shown to be special cases of a general potential whose energy and spacing are expressible in terms of them.

1982-11-01

314

Many-Body Rate Limit on Photoassociation of a Bose-Einstein Condensate  

CERN Document Server

We briefly report on zero-temperature photoassociation of a Bose-Einstein condensate, focusing on the many-body rate limit for atom-molecule conversion. An upgraded model that explicitly includes spontaneous radiative decay leads to an unanticipated shift in the position of the photoassociation resonance, which affects whether the rate (constant) maximizes or saturates, as well as the limiting value itself. A simple analytical model agrees with numerical experiments, but only for high density. Finally, an explicit comparison with the two-body unitary limit, set by the size of the condensate, finds that the many-body rate limit is generally more strict.

2010-01-01

315

Results of 3-dimensional structural FE-modeling of the coil end-regions of the LHC main dipoles  

CERN Document Server

The transition region between the straight part and the ends of the coils of the LHC model and prototype dipole magnets are often identified as the origin of training quenches. In order to study how the discontinuities in the material properties of these regions affect coil pre-stress and possibly gain more insight in the quench behavior, a program was set up at CERN to analyze by 3D-FEM these particular regions. The ACCEL team, who performed a similar analysis for the main quadrupoles of the Superconducting Supercollider SSC, is entrusted with this program. In this paper we report on the results of 3D-modeling and analysis of the coil return end region, including the complete coil mass, of a 1-m single bore model magnet. This magnet represents all relevant features of the "two-in-one" LHC main dipole design concerning the winding configuration, the collar pack, ...

2000-01-01

316

Value of MRCP using oral Gd-DTPA as negative contrast materials in diagnosis of atypical juxtapapillary duodenal diverticulum  

British Library Electronic Table of Contents (United Kingdom)

Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imaging findings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...

2009-01-01

317

The role of MRI in the diagnosis of recurrent/persistent carpal tunnel syndrome: A radiological and intra-operative correlation  

British Library Electronic Table of Contents (United Kingdom)

MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...

2011-01-01

318

The influence of normal human ageing on automatic movements  

British Library Electronic Table of Contents (United Kingdom)

There is evidence that aged normal subjects have more difficulty in achieving automaticity than young subjects. The underlying central neural mechanism for this phenomenon is unclear. In the present study, functional magnetic resonance imaging (fMRI) was used to investigate the effect of normal ageing on automaticity. Aged healthy subjects were asked to practice self-initiated, self-paced, memorized sequential finger movements with different complexity until they could perform the tasks automatically. Automaticity was evaluated by having subjects perform a secondary task simultaneously with the sequential movements. Although it took more time, most aged subjects eventually performed the tasks automatically at the same level as the young subjects. Functional MRI results showed that, for bot...

2005-01-01

319

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

320

Study of the cyclotron feature in MXB 0656-072  

CERN Document Server

We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.

2006-01-01

321

Steady particulate flows in a horizontal rotating cylinder  

Energy Technology Data Exchange (ETDEWEB)

Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRI) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio {approximately}7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity field in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit. {copyright} {ital 1998 American Institute of Physics.}

1998-06-01

322

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

323

Primary and multisensory cortical activity is correlated with audiovisual percepts  

British Library Electronic Table of Contents (United Kingdom)

Incongruent auditory and visual stimuli can elicit audiovisual illusions such as the McGurk effect where visual /ka/ and auditory /pa/ fuse into another percept such as/ta/. In the present study, human brain activity was measured with adaptation functional magnetic resonance imaging to investigate which brain areas support such audiovisual illusions. Subjects viewed trains of four movies beginning with three congruent /pa/ stimuli to induce adaptation. The fourth stimulus could be (i) another congruent /pa/, (ii) a congruent /ka/, (iii) an incongruent stimulus that evokes the McGurk effect in susceptible individuals (lips /ka/ voice /pa/), or (iv) the converse combination that does not cause the McGurk effect (lips /pa/ voice/ ka/). This paradigm was predicted to show increased release fro...

2010-01-01

324

Preliminary studies on the chemical characterization and antioxidant properties of acidic polysaccharides from Sargassum fusiforme  

British Library Electronic Table of Contents (United Kingdom)

In order to investigate the antioxidant properties of the polysaccharides from the brown alga Sargassum fusiforme, the crude polysaccharides from S. fusiforme (SFPS) were extracted in hot water, and the lipid peroxidation inhibition assay exhibited that SFPS possessed a potential antioxidant activity. Hence, two purely polymeric fractions, SFPS-1 and SFPS-2 were isolated by the column of DEAE (2-diethylaminoethanol)-Sepharose Fast Flow, with their molecular weights of 51.4 and 30.3 kDa determined by high performance gel permeation chromatography (HPGPC). They were preliminarily characterized using chemical analysis in combination of infrared (IR) and nuclear magnetic resonance (NMR) spectroscopies and found to contain large amounts of uronic acids and ?-glycosidical linkages. The antioxida...

2008-01-01

325

Point defects in dilute nitride III-N-As and III-N-P  

International Nuclear Information System (INIS)

We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.

2006-04-01

326

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the ...

2009-03-01

327

Oxidation of polycaprolactone to induce compatibility with other degradable polyesters  

British Library Electronic Table of Contents (United Kingdom)

Chemical modification of poly(?-caprolactone) PCL by oxidation with potassium permanganate in solution was investigated. According to the data obtained from Fourier transform infrared spectroscopy (FT-IR) and nuclear magnetic resonance 1H NMR, after the oxidation reactions the PCL chains exhibited new functional groups (vinyl and hydroxyl) and possible intermolecular recombination, producing an oxidized-polycaprolactone (PCL-OX). Solution viscometry indicated that degradation also occurred during the oxidation reactions (30% drop in viscosity average molecular weight was detected). Differential scanning calorimetry (DSC) also indicated that PCL was chemically modified and degraded. The successive self-nucleation/annealing (SSA) treatment confirmed that a reduction (or interruption) in line...

2007-01-01

328

Mapping subcortical diffusivity. Application to brain development. Presidential award proceeding  

International Nuclear Information System (INIS)

We studied age-related microstructural changes in the subcortical white matter from adolescence to middle age in 16 healthy male subjects (age range: 12 to 47 years) using diffusion-weighted magnetic resonance (MR) imaging (DWI). Mean diffusivity (MD) of subcortical white matter was mapped onto the overlying cortical surface using our original method. The mean MD values within 76 cortical regions were measured using atlas-based gray matter segmentation and then correlated with age. A significant negative correlation with age was observed in subcortical MD values in several cortical regions, primarily over the bilateral temporal and occipital lobes. Our results demonstrated subcortical microstructural change in postadolescence that may reflect continuing myelination. (author)

2007-01-01

329

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

330

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

331

Influence of attention focus on neural activity in the human spinal cord during thermal sensory stimulation  

British Library Electronic Table of Contents (United Kingdom)

Perceptions of sensation and pain in healthy people are believed to be the net result of sensory input and descending modulation from brainstem and cortical regions depending on emotional and cognitive factors. Here, the influence of attention on neural activity in the spinal cord during thermal sensory stimulation of the hand was investigated with functional magnetic resonance imaging by systematically varying the participants' attention focus across and within repeated studies. Attention states included (1) attention to the stimulus by rating the sensation and (2) attention away from the stimulus by performing various mental tasks of watching a movie and identifying characters, detecting the direction of coherently moving dots within a randomly moving visual field and answering mentally-...

2011-01-01

332

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. MRI ...

2006-06-01

333

Fetal MRI of pathological brain development  

International Nuclear Information System (INIS)

Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)

2006-02-01

334

Experimental parameterization of an energy function for the simulation of unfolded proteins  

DEFF Research Database (Denmark)

The determination of conformational preferences in unfolded and disordered proteins is an important challenge in structural biology. We here describe an algorithm to optimize energy functions for the simulation of unfolded proteins. The procedure is based on the maximum likelihood principle and employs a fast and efficient gradient descent method to find the set of parameters of the energy function that best explain the experimental data. We first validate the method by using synthetic reference data, and subsequently apply the algorithms to data from nuclear magnetic resonance spin-labeling experiments on the Delta 131 Delta fragment of Staphylococcal nuclease. A significant strength of the procedure that we present is that it directly uses experimental data to optimize the energy parameters, without relying on the availability of high resolution structures. The procedure is fully general and can be applied to a range of experimental data and ...

2008-01-01

335

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

336

Episodic Future Thinking Reduces Reward Delay Discounting through an Enhancement of Prefrontal-Mediotemporal Interactions  

British Library Electronic Table of Contents (United Kingdom)

Summary Humans discount the value of future rewards over time. Here we show using functional magnetic resonance imaging (fMRI) and neural coupling analyses that episodic future thinking reduces the rate of delay discounting through a modulation of neural decision-making and episodic future thinking networks. In addition to a standard control condition, real subject-specific episodic event cues were presented during a delay discounting task. Spontaneous episodic imagery during cue processing predicted how much subjects changed their preferences toward more future-minded choice behavior. Neural valuation signals in the anterior cingulate cortex and functional coupling of this region with hippocampus and amygdala predicted the degree to which future thinking modulated individual preference fu...

2010-01-01

337

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

338

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

339

Early diagnosis of skeletal disorders in childhood and adolescence by MRI; Fruehdiagnose orthopaedischer Erkrankungen des Kindes- und Jugendalters mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)

1998-09-18

340

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

341

Characterization of physically vapor deposited AF2400 thin films  

Energy Technology Data Exchange (ETDEWEB)

Anti-reflective coatings made with Teflon AF2400 had the highest damage thresholds recorded for physical vapor deposited coatings at the Lawrence Livermore National Laboratory damage facility. Physical vapor deposited layers of Teflon AF2400, a perfluorinated amorphous polymer, maintained the bulk optical properties of a high transmittance from 200 nm to 1600 nm, and a low refractive index. In addition, the refractive index can be intentionally reduced by control of two common deposition parameters, deposition rate and substrate temperature. Scanning electron microscopy and nuclear magnetic resonance observations indicated that morphological changes caused the variations in the refractive index rather than compositional changes. The coatings adhered to fused silica and silicon wafers under normal laboratory handling conditions.

1993-11-01

342

Brain tumor in childhood. Hjernesvulst hos barn  

Energy Technology Data Exchange (ETDEWEB)

Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.

1990-05-01

343

Biopolymer system for permeability modification in porous media  

Energy Technology Data Exchange (ETDEWEB)

New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were ...

1995-12-31

344

Biochemical monitoring of black raspberry (Rubus coreanus Miquel) fruits according to maturation stage by ^1H NMR using multiple solvent systems  

British Library Electronic Table of Contents (United Kingdom)

Nuclear magnetic resonance (NMR) techniques coupled with multivariate data analysis were used to conduct monitoring of biochemical changes of black raspberry fruits at different stages of maturation and under various extraction and NMR dissolution solvent conditions: extraction with 50% methanol and D"2O as an NMR dissolution solvent, extraction with 50% methanol and 50% methanol-d"4 as an NMR dissolution solvent, and extraction with 100% ethyl acetate and 100% methanol-d"4 as an NMR dissolution solvent. Partial least-squares discriminant analysis reliably distinguished black raspberry fruits according to the maturation stage, whereby the relative levels of various compounds such as amino acids, organic acids, sugars and phenolic compounds were compared using analysis of variance. Sucrose ...

2011-01-01

345

Controlling Charge and Current Neutralization of an Ion Beam Pulse in a Background Plasma by Application of a Solenoidal Magnetic Field I: Weak Magnetic Field Limit  

Energy Technology Data Exchange (ETDEWEB)

Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite- length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to infuence the self-electric and self-magnetic fields when ?ce > ?pe?b, where ?ce = e?/mec is the ...

2008-10-10

346

Simulations of a ring resonator free-electron laser  

International Nuclear Information System (INIS)

In this paper, a relatively high gain (#approx =# 25 to 40 percent) free-electron laser (FEL) with an optical ring resonator is simulated using the code FELEX. The laser system corresponds to the ''burst mode'' FEL scheduled for operation at Boeing Aerospace Company in 1988. The ring consists of paraboloids, grazing incidence by hyperboloids, and a grating rhomb. The wiggler is 5 m in length and has an adjustable taper, while the electron beam is produced by an RF linac. The optical elements of the ring together with the FEL interaction in the wiggler are modeled in three spatial dimensions to investigate the system from start-up to saturation. Both single frequency and finite pulse simulations are performed. The study illustrates the necessity of mode matching the loaded resonator to maximize the extraction efficiency. The mode matching is necessary because the FEL interaction significantly alters the optical beam focus ...

347

Microstructure modifications and modulated piezoelectric responses in PLZT/Al{sub 2}O{sub 3} composites  

Energy Technology Data Exchange (ETDEWEB)

Piezoelectric ceramics for acoustic applications have been prepared by mixing the piezoelectric phase Pb{sub 1-1.5x}La{sub x}{open_square}{sub x/2}(Ti{sub 1-y}Zr{sub y})O{sub 3} (PLZT) with variable fractions of Al{sub 2}O{sub 3}. The samples are in form of pellets and polarized at high temperature. After thermal treatment, X-ray diffraction and scanning electron microscopy have been used to determine the phase and morphological modifications. The morphotropic PLZT initial phase disproportionates into modified PLZT and ZrO{sub 2} phases. Using electrical impedance spectroscopy, the resonance frequencies of the composite system have been determined and analyzed. As the Al{sub 2}O{sub 3} volume fractions increase, the resonance frequency and the amplitude of the electrical response both decrease. An interpretation of the role of Al{sub 2}O{sub 3} additions is proposed in terms of phase and microstructure modifications. Using LRC electrical ...

2003-01-15

348

Evaluation of fetal brain development by magnetic resonance imaging. Subependymal germinal matrix layer and cerebral ventricle  

International Nuclear Information System (INIS)

Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The relation between fetal ages and volume of cerebral ventricle also showed similar pattern. This method will be useful to examine the development of the ...

1999-10-01

349

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that ...

1996-01-01

350

Assembly of Linear Nano-Chains from Iron Oxide Nanospheres with Asymmetric Surface Chemistry  

Science.gov (United States)

Besides the multifunctionality, another equally important aspect of nanoparticles is their engineerability to control the geometrical and chemical properties during fabrication. In this work, we exploited this aspect to define asymmetric surface chemistry of an iron oxide nanosphere by controlling the topology of ligand expression on its surface resulting in a particle with two faces, one displaying only amines and the other only thiols. Specifically, amine-functionalized iron oxide nanospheres were attached on a solid support via a crosslinker containing a disulfide bridge. Liberation of the nanosphere using thiolytic cleavage created thiols on the portion of the particle's surface that interacted with the solid support. Employing a solid-phase strategy and a step-by-step addition of particles, the two unique faces on the same nanosphere served as fittings to assemble them into linear nano-chains. Assembly of chains with various lengths and aspect ratios was controlled by the size and ...

2011-01-06

351

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum control of the radial overlap of the laser/negative ion beam ...

2008-09-01

352

Use of shell model calculations in R-matrix studies of neutron-induced reactions  

Energy Technology Data Exchange (ETDEWEB)

R-matrix analyses of neutron-induced reactions for many of the lightest p-shell nuclei are difficult due to a lack of distinct resonance structure in the reaction cross sections. Initial values for the required R-matrix parameters, E,sub(lambda) and ..gamma..sub(lambdac) for states in the compound system, can be obtained from shell model calculations. In the present work, the results of recent shell model calculations for the lithium isotopes have been used in R-matrix analyses of /sup 6/Li+n and /sup 7/Li+n reactions for E sub(n) < 8 MeV. Consequences of the shell model predictions for the level structure of /sup 7/Li and /sup 8/Li on the /sup 6/Li+n and /sup 7/Li+n reaction mechanisms and cross sections are discussed.

1986-01-01

353

Spectral Modeling of Magnetohydrodynamic Turbulent Flows  

CERN Document Server

We present a dynamical spectral model for Large Eddy Simulation of the incompressible magnetohydrodynamic (MHD) equations based on the Eddy Damped Quasi Normal Markovian approximation. This model extends classical spectral Large Eddy Simulations for the Navier-Stokes equations to incorporate general (non Kolmogorovian) spectra as well as eddy noise. We derive the model for MHD and show that introducing a new eddy-damping time for the dynamics of spectral tensors in the absence of equipartition between the velocity and magnetic fields leads to better agreement with direct numerical simulations, an important point for dynamo computations.

2008-01-01

354

The models of experimental magnetic measurements of various biological samples  

International Nuclear Information System (INIS)

Complete text of publication follows. At the Geomagnetic Institute, in the Laboratory for paleomagnetism and archeomagnetism research and at the Geomagnetic Observatory, Grocka (GCK) during the period from November 2004 to February 2008 the researchers carried out experimental magnetic measurements of the total-intensity gradient of the magnetic field vector (changes in the total magnetisation vector) of various biomaterials. Measurements of the gradient total intensity of the magnetic field vector were carried out by GSM-19 magnetometers of high accuracy and recording resolution (accuracy: #DELTA#F=0.1 nT; sampling rate: 1-5 per second). During these experimental biomagnetic measurements samples of water, tissue, blood, cotton, wool, pitch and magnetite-powder were used. In this study, the part of the biomagnetic measurement results relate to the water, blood and tissue. The results of the measurements of gradient ...

2009-08-23

355

A modular and extensible data acquisition and control system for testing superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into operation. This system utilizes a modular approach that provides both ...

2001-07-20

356

Magnetic properties of Ab initio model of iron-based superconductors LaFeAsO  

International Nuclear Information System (INIS)

By using a variational Monte Carlo method, we examine an effective low-energy model for LaFeAsO derived from an ab initio downfolding scheme. We show that quantum and many-body fluctuations near the antiferromagnetic (AF) quantum critical point largely reduce the antiferromagnetic ordered moment. Our derived model not only quantitatively reproduces the small ordered moment in LaFeAsO, but also accounts for the diversity from LaFePO, BaFe_2As_2 to FeTe. Electron correlation is found to determine the observed material dependence. We also find that LaFeAsO is subject to large orbital fluctuations, sandwiched by the AF Mott insulator and weakly correlated metals. The orbital fluctuations and Dirac-cone dispersion hold keys for the diverse magnetic properties. (author)

2011-02-01

358

Polaron model of electron spectra and superconductivity of A-15 compounds  

Energy Technology Data Exchange (ETDEWEB)

The existence of a narrow peak of electron state density in A-15 is explained by a strong electron-phonon interaction that brings about the polaron narrowing of zone. In the supposition of weak and intermediate bond, the analytical expression for the critical transition temperature is found that corre lates Tsub(c) with phonon spectrum. The model permits to explain Tsub(c) correlation with the number of electrons per atom, temperature direction of resistance, value and temperature dependence of magnetic susceptibility and electron thermal capacity.

1983-02-01

359

Polaron model of electron spectra and superconductivity of A-15 compounds  

International Nuclear Information System (INIS)

The existence of a narrow peak of electron state density in A-15 is explained by a strong electron-phonon interaction that brings about the polaron narrowing of zone. In the supposition of weak and intermediate bond, the analytical expression for the critical transition temperature is found that corre lates Tsub(c) with phonon spectrum. The model permits to explain Tsub(c) correlation with the number of electrons per atom, temperature direction of resistance, value and temperature dependence of magnetic susceptibility and electron tehrmal capacity.

360

M 1 decay rates of heavy quarkonia with a nonsingular potential  

Energy Technology Data Exchange (ETDEWEB)

We use a nonsingular-potential model for heavy quarkonia proposed by Gupta, Repko, and Suchyta to calculate the transition amplitudes for the magnetic-dipole ({ital M}1) one-photon radiative decays of the {ital c{bar c}} and {ital b{bar b}} bound systems. The wave functions of the bound systems are calculated by a nonperturbative treatment. The results are in better agreement with the experimental data than those predicted using other potential models.

1991-09-01

361

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

362

Computer modelling of eddy current probes  

International Nuclear Information System (INIS)

Computer programs have been developed for modelling impedance and transmit-receive eddy current probes in two-dimensional axis-symmetric configurations. These programs, which are based on analytic equations, simulate bobbin probes in infinitely long tubes and surface probes on plates. They calculate probe signal due to uniform variations in conductor thickness, resistivity and permeability. These signals depend on probe design and frequency. A finite element numerical program has been procured to calculate magnetic permeability in non-linear ferromagnetic materials. Permeability values from these calculations can be incorporated into the above analytic programs to predict signals from eddy current probes with permanent magnets in ferromagnetic tubes. These programs were used to test various probe designs for new testing applications. Measurements of magnetic permeability in ...

1992-10-01

363

Anomalous tensor magnetic moments and form factors of the proton in the self-consistent chiral quark-soliton model  

Science.gov (United States)

We investigate the form factors of the chiral-odd nucleon matrix element of the tensor current. In particular, we aim at the anomalous tensor magnetic form factors of the nucleon within the framework of the SU(3) and SU(2) chiral quark-soliton model. We consider 1/N{sub c} rotational corrections and linear effects of SU(3) symmetry breaking with the symmetry-conserving quantization employed. We first obtain the results of the anomalous tensor magnetic moments for the up and down quarks: {kappa}{sub T}{sup u}=3.56 and {kappa}{sub T}{sup d}=1.83, respectively. The strange anomalous tensor magnetic moment is yielded to be {kappa}{sub T}{sup s}=0.2{approx}-0.2, that is compatible with zero. We also calculate the corresponding form factors {kappa}{sub T}{sup q}(Q{sup 2}) up to a momentum transfer Q{sup 2{<=}}1 GeV{sup 2} at a renormalization scale of 0.36 GeV{sup 2}.

2010-09-01

364

High-temperature ferromagnetism in laser-deposited layers of silicon and germanium doped with manganese or iron impurities  

Energy Technology Data Exchange (ETDEWEB)

The paper reports on the results of a study of the synthesis conditions effects on magnetic and transport properties of nanosized layers of high-T{sub c} diluted magnetic semiconductors (DMS), such as Ge:Mn, Si:Mn and Si:Fe, fabricated by laser-plasma deposition over a wide range of the growth temperature, T{sub g}=(20-550) deg. C on single-crystal GaAs or Al{sub 2}O{sub 3} substrates. Ferromagnetism of the layers was detected by measurement data of the magneto-optical Kerr effect, anomalous Hall effect, negative magnetoresistance and ferromagnetic resonance (FMR) at 5-500 K. The optimum growth temperature, T{sub g}, for Si:Mn/GaAs layers with T{sub c}{approx}400 K is shown to be about 400 deg. C. The Si:Mn/Al{sub 2}O{sub 3} layers with 35% of Mn have the metal-type of conductivity with manifestation of magnetization up to room temperature. Different types of uniformly doped structures and digital ...

2009-04-15

367

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal ...

1999-10-01

368

Transverse-field Formula Not Shown SR and magnetic disorder in Formula Not Shown  

British Library Electronic Table of Contents (United Kingdom)

We have carried out transverse-field ( Formula Not Shown ) Formula Not Shown SR experiments in Formula Not Shown for temperatures from 300 down to 2.2K. The muon-decay asymmetry can be fit to a stretched exponential relaxation function: Formula Not Shown . The exponent Formula Not Shown for Formula Not Shown , but drops continuously below this temperature (being Formula Not Shown for Formula Not Shown and reaching Formula Not Shown near 2K). The characteristic relaxation rate Formula Not Shown grows six-fold in the experimental temperature range (from Formula Not Shown for Formula Not Shown to Formula Not Shown for Formula Not Shown ). Independently of theoretical models, the behavior of these parameters is consistent with strong magnetic disorder. Although the magnetic susceptibility of F...

2008-01-01

369

Research and development project for flywheel energy storage system using high-temperature superconducting magnetic bearing  

Energy Technology Data Exchange (ETDEWEB)

Recent progress in yttrium-based oxide high-temperature superconductors has enabled the production of a large diameter bulk with a strong flux-pinning force. A combination of this superconductor and a permanent magnet makes it feasible to fabricate a noncontact, non-controlled superconducting magnetic bearing with a very small rotational loss, applicable to a flywheel energy storage system. A conceptual design of an 8 MWh flywheel energy storage system using the new bearing has been developed, based on measured data on a miniature bearing model, which proved to be potentially capable of achieving a high energy storage efficiency of 84 pc. A 100 W h-class experimental system was then built, which attained a high revolution rate of 17000 rpm, with a rotational loss of about 0.6 W. (authors). 2 refs., 7 figs., 3 tabs.

1995-12-31

370

Combined effect of magnetic field and heat absorption on unsteady free convection and heat transfer flow in a micropolar fluid past a semi-infinite moving plate with viscous dissipation using element free Galerkin method  

British Library Electronic Table of Contents (United Kingdom)

The fully developed electrically conducting micropolar fluid flow and heat transfer along a semi-infinite vertical porous moving plate is studied including the effect of viscous heating and in the presence of a magnetic field applied transversely to the direction of the flow. The Darcy-Brinkman-Forchheimer model which includes the effects of boundary and inertia forces is employed. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. Profiles for velocity, microrotation and temperature are presented for a wide range of plate velocity, viscosity ratio, Darcy number, Forchhimer number, magnetic field parameter, heat absorption ...

2010-01-01

371

Nuclear magnetic moments of "1"7"5Ta and "1"7"7Ta  

International Nuclear Information System (INIS)

"1"7"5Ta and "1"7"7Ta nuclei as dilute impurities in Fe were oriented at low temperatures. Using the technique of NMR/ON the magnetic moments have been measured: "+#mu#("1"7"5Ta, 7/2"+,"+=2.270(45) #mu# sub(N) and "+#mu#("1"7"5Ta, 7/2"+)"+=2.250(45) #mu# sub(N). These values are discussed in the framework of the rotational model. (author).

372

Magnetic susceptibility of the A-15 compound system (Vsub(1-x)Crsub(x))_3Si  

International Nuclear Information System (INIS)

The magnetic susceptibility of single and polycrystalline samples of the A-15 compounds (Vsub(1-x)Crsub(x))_3Si (0 <= x <= 1) is measured at temperatures between 4.2 and 320 K. The magnitude and the temperature dependence of the susceptibility diminish with increasing Cr concentration. Applying a peak model for the density of electronic states it is found that the change of the temperature dependence of the susceptibility with increasing Cr concentration is caused mainly by broadening of the peak in the density of electronic states. (author).

373

Creation of an antiferromagnetic exchange spring  

Science.gov (United States)

We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.

2004-04-06

374

Chiral solitons in nuclei: Electromagnetic form factors  

Science.gov (United States)

We calculate the electromagnetic form factors of a bound proton. The chiral quark-soliton model provides the quark and antiquark substructure of the proton, which is embedded in nuclear matter. This procedure yields significant modifications of the form factors in the nuclear environment. The sea quarks are almost completely unaffected, and serve to mitigate the valence quark effect. In particular, the ratio of the isoscalar electric to the isovector magnetic form factor decreases by 20% at Q{sup 2}=1 GeV{sup 2} at nuclear density, and we do not see a strong enhancement of the magnetic moment.

2004-12-01

375

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...

2003-03-01

376

Magnetic resonance imaging assessment of brain maturation in preterm neonates with punctate white matter lesions  

International Nuclear Information System (INIS)

Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with 22 matched controls with a normal MR appearance. The two groups ...

2007-02-01

377

Magnetic Resonance Perfusion Imaging in Malformations of Cortical Development  

International Nuclear Information System (INIS)

Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side (rCBVRTSC and TTFMTSC) as well as those of the polymicrogyria/contralateral side ...

2007-10-01

378

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with transient ischemic attacks (TIA) and the ...

1997-05-01

379

Hilar cholangiocarcinoma: MR correlation with surgical and histological findings  

International Nuclear Information System (INIS)

Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the ...

2010-10-01

380

Functional magnetic resonance imaging of the normal and abnormal visual system in early life.  

DEFF Research Database (Denmark)

Functional magnetic resonance imaging (fMRI) in young children may provide information about the development of the visual cortex, and may have predictive value for later visual performance. The purpose of this study was to evaluate the usefulness of fMRI for examining cerebral processing of vision in very young infants and in infants with brain damage. We examined 15 preterm infants, 12 children suspected of having a cerebral visual impairment and 10 children with a normal visual system, all of whom were either spontaneously asleep or sedated with chloral hydrate. Cortical response to stroboscopic light stimulation could be demonstrated in all technically acceptable data sets from children with a post-menstrual age (PMA) of > 41 weeks, but not in younger infants. Children < 60 weeks PMA showed either a blood oxygenation level-dependent (BOLD) signal increase or decrease, while all older children showed a signal decrease. The activated ...

2000-01-01

381

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have ...

2008-04-15

382

Detection of Cholangiocarcinoma with Magnetic Resonance Spectroscopy of Bile in Patients with and without Primary Sclerosing Cholangitis  

International Nuclear Information System (INIS)

Background: Early detection of cholangiocarcinoma (CC) is very difficult, especially in patients with primary sclerosing cholangitis (PSC) who are at increased risk of developing CC. Purpose: To evaluate "1H magnetic resonance spectroscopy ("1H-MRS) of bile as a diagnostic marker for CC in patients with and without PSC. Material and Methods: The institutional review board approved the study, and all patients gave informed consent. Bile from 49 patients was sampled and investigated using "1H-MRS. MR spectra of bile samples from 45 patients (18 female; age range 22-87 years, mean age 57 years) were analyzed both conventionally and using computerized multivariate analysis. Sixteen of the patients had CC, 18 had PSC, and 11 had other benign findings. Results: The spectra of bile from CC patients differed from the benign group in the levels of phosphatidylcholine, bile acids, lipid, and cholesterol. It was possible to distinguish CC from benign ...

2008-10-01

383

Characterization of Absolute-Resonant Eddy Current Probes,  

Science.gov (United States)

... Accession Number : ADD335809. Title : Characterization of Absolute-Resonant Eddy Current Probes,. Corporate Author : ...

384

Monitoring noise-resonant effects in cancer growth influenced by spontaneous fluctuations and periodic treatment  

CERN Document Server

In the paper we investigate a mathematical model describing the growth of tumor in the presence of immune response of a host organism. The dynamics of tumour and immune cells is based on the generic Michaelis-Menten kinetics describing interaction and competition between the tumour and the immune system. The appropriate phenomenological equation modeling cell-mediated immune surveillance against cancer is of the predator-prey form and within a given choice of parameters exhibits bistability. Under the influence of spontaneous weak fluctuations, the model may be analyzed in terms of a stochastic differential equation bearing the form of an overdamped Langevin-like dynamics in the external quasi-potential represented by a double well. We analyze properties of the system within the range of parameters for which the potential wells are of the same depth and when the additional perturbation describing a periodic treatment is ...

2007-01-01

385

A Study on A Semi-Submersible Floating Offshore Wind Energy Conversion System  

Energy Technology Data Exchange (ETDEWEB)

A new semi-submersible floating structure is proposed on which three wind turbine towers are installed. This paper presents a basic characteristic of the wave-induced motion of this semi-submersible floating structure via. numerical computations and 1/150 scaled rigid model experiments in a wave tank. In the numerical computations, nonlinear damping effect due to drag forces modeled by the Morison's formula is considered in the equation of motion, where the linear hydrodynamic forces are obtained from the Green's function model. As a result, the response characteristics around the resonant frequency region were successfully improved. In addition to such basic examination, major results of feasibility studies, including the structural stability for severe wave conditions and the long-term fatigue limit state, are presented for a realistic situation.

2007-07-01

386

On the validity of the pseudo-spin concept for axially symmetric deformed nuclei  

International Nuclear Information System (INIS)

The average single-particle field shows a very small pseudo-spin-orbit splitting in the pseudo-spin representation. If this splitting is neglected, pseudo-spin becomes a good quantum number and the resulting scheme (the pseudo-Nilsson model) has a very simple interpretation. The pseudo-spin symmetry embodied in the realistic deformed average field is explored by comparing the single-particle energies and wave functions of the deformed Woods-Saxon model with the corresponding results of the pseudo-Nilsson model. The scheme is used to calculate the magnetic moments of deformed odd-A nuclei of the rare-earth region. (orig.).

387

Moderate Deviations for a Curie-Weiss model with dynamical external field  

CERN Document Server

In the present paper we prove moderate deviations for a Curie-Weiss model with external magnetic field generated by a dynamical system, as introduced by Dombry and Guillotin-Plantard. The results extend those already obtained in the case of a constant external field by Eichelsbacher and L\\"owe. The Curie-Weiss model with dynamic external field is related to the so called dynamic Z-random walks. We also prove a moderate deviation result for the dynamic Z-random walk, completing the list of limit theorems for this object.

2011-01-01

388

Particle Swarm Optimization: An efficient method for tracing periodic orbits in 3D galactic potentials  

CERN Document Server

We propose the Particle Swarm Optimization (PSO) as an alternative method for locating periodic orbits in a three--dimensional (3D) model of barred galaxies. We develop an appropriate scheme that transforms the problem of finding periodic orbits into the problem of detecting global minimizers of a function, which is defined on the Poincar\\'{e} Surface of Section (PSS) of the Hamiltonian system. By combining the PSO method with deflection techniques, we succeeded in tracing systematically several periodic orbits of the system. The method succeeded in tracing the initial conditions of periodic orbits in cases where Newton iterative techniques had difficulties. In particular, we found families of 2D and 3D periodic orbits associated with the inner 8:1 to 12:1 resonances, between the radial 4:1 and corotation resonances of our 3D Ferrers bar model. The main advantages of the proposed algorithm is its ...

2005-01-01

389

Radio-Frequency Beam Conditioner for Fast-Wave Free-Electron Generators of Coherent Radiation  

Energy Technology Data Exchange (ETDEWEB)

A method for conditioning electron beams is proposed, making use of the TM{sub 210} mode of microwave cavities, to reduce the axial velocity spread within the beam, in order to enhance gain in resonant electron beam devices, such as the free-electron laser (FEL). Effectively, a conditioner removes the restriction on beam emittance. The conditioner is analyzed using a simple model for beam transport and ideal RF cavities. Analysis of an FEL is employed to evaluate performance with reduced axial velocity spread. Examples of FELs are presented showing the distinct advantage of conditioning.

1991-07-01

390

Production of MSSM Higgs bosons in {gamma}{gamma} collisions  

Energy Technology Data Exchange (ETDEWEB)

The heavy Higgs bosons H,A of the minimal supersymmetric extension of the Standard Model can be produced as resonances in high-energy {gamma}{gamma} colliders. Prospects of the search for these particles in bb-bar and neutralino-pair final states are studied in this report. Heavy Higgs bosons can be found with masses up to about 70-80% of the initial e{sup +}e{sup -} collider energy for moderate values of tan {beta}, i.e. in areas of the parameter space not accessible at other colliders.

2001-10-11

391

Production of MSSM Higgs bosons in photon-photon collisions  

Energy Technology Data Exchange (ETDEWEB)

The heavy neutral Higgs bosons H, A in the minimal supersymmetric extension of the standard model can be produced as single resonances at high-energy {gamma}{gamma} colliders. We have studied the prospects of the search for these particles in bb and neutralino-pair final states. The Higgs bosons can be found with masses up to 70-80% of the initial e{sup {+-}}e{sup -} collider energy for medium values of tg{beta}, i.e. in areas of the supersymmetric parameter space not accessible at other colliders. (orig.)

2000-12-01

392

Local lattice structure, crystal field and energy level patterns in CsCdBr_3:Tm"3"+ crystals  

International Nuclear Information System (INIS)

In CsCdBr_3, Tm"3"+ substitutes for Cd"2"+. It predominately forms symmetric dimer centers and single-ion centers, both of trigonal symmetry. The energy level schemes of both centers were determined by EPR and site-selective laser spectroscopy. To describe the spectra term dependent crystal-field parameters were deduced on the basis of a microscopic model taking into account the local lattice deformation induced by the impurity centers and the quasi-resonant virtual scattering of intrinsic lattice excitations by the Tm"3"+ ions. (orig.)

1998-07-24

393

Lack of oscillations in Dual-Phase-Lagging heat conduction for a porous slab subject to imposed heat flux and temperature  

Energy Technology Data Exchange (ETDEWEB)

This study shows that the physical conditions necessary for thermal waves to materialize in Dual-Phase-Lagging porous media conduction are not attainable in a porous slab subject to a combination of constant heat flux and temperature (Neumann and Dirichlet) boundary conditions. It is demonstrated that the approximate equivalence between Dual-Phase-Lagging (DuPhlag) heat conduction model and the Fourier heat conduction in porous media subject to Lack of Local Thermal Equilibrium (La Lotheq) that suggested the possibility of thermal oscillations and resonance reveals a condition that cannot be fulfilled because of physical constraints. (author)

2005-07-01

394

Recent activites on electromagnetic processing of materials in Japan  

Energy Technology Data Exchange (ETDEWEB)

Application of electromagnetic forces to materials processing, so-called {open_quotes}electromagnetic processing of materials (EPM){close_quotes} has been recognized as cutting edge technology, especially in the fields of steelmaking and advanced materials processing in Japan. The history of EPM in Japan is mentioned and the background to promote EPM is described. The current status of research and development of EPM is shown briefly introducing several examples. Regarding the application of high-frequency magnetic field, two topics are dealt with. The first is the improvement of the surface quality of cast steel where an alternating magnetic field is imposed on the molten steel from the outside of the mold, and the second is the induction cold crucible where a considerably large amount of molten intermetallic compound is levitated. Examples of the application of DC magnetic field are the control of molten steel flow in a ...

1995-01-01

395

Magnetic field-induced currents in the human body in proximity of power lines  

Energy Technology Data Exchange (ETDEWEB)

Electric currents induced due to 60 Hz magnetic fields in a human body placed in a close proximity of various high voltage transmission lines are computed. A realistic model of the human body from the anatomical and electrical point of view with resolution of 1.3 cm for the body and 0.665 cm for the head is used. The computations are performed using the impedance method. Three representative configurations of high voltage transmission lines, namely 500 kV, 138 kV and 25 kV are analyzed. The results indicate that the maximum current densities of the order of 0.2 {micro}A/cm{sup 2} can be induced in a lineman working on a 500 kV line (0.5 m away from closest conductors). A good correlation can be seen between the computed magnetic field in the location of the human body and the induced current densities. The induced currents computed here and estimated from measured magnetic fields in various power line ...

1996-01-01

396

Magnetic Fields in Massive Stars. II. The Buoyant Rise of Magnetic Flux Tubes Through the Radiative Interior  

CERN Document Server

We present results from an investigation of the dynamical behavior of buoyant magnetic flux rings in the radiative interior of a uniformly rotating early-type star. Our physical model describes a thin, axisymmetric, toroidal flux tube that is released from the outer boundary of the convective core, and is acted upon by buoyant, centrifugal, Coriolis, magnetic tension, and aerodynamic drag forces. We find that rings emitted in the equatorial plane can attain a stationary equilibrium state that is stable with respect to small displacements in radius, but is unstable when perturbed in the meridional direction. Rings emitted at other latitudes travel toward the surface along trajectories that largely parallel the rotation axis of the star. Over much of the ascent, the instantaneous rise speed is determined by the rate of heating by the absorption of radiation that diffuses into the tube from the external medium. Since the time ...

2003-01-01

397

Transformation of the ATOMKI-ECRIS into a Plasma Device  

International Nuclear Information System (INIS)

Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check the components and charge-state of the plasma. A new, large, but ...

2006-01-01

398

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

399

Role of core toroidal rotation on the H-mode radial electric field shear, turbulence, and confinement as studied by magnetic braking in the DIII-D tokamak  

International Nuclear Information System (INIS)

''Magnetic braking'' of the plasma toroidal rotation in the high confinement H mode by applied resonant, low m,n=1 static error fields is used in DIII-D [Nucl. Fusion 31, 875 (1991)] as an independent control to evaluate the E_rxB stabilization of microturbulence in the plasma core. In the core (#rho# approx-lt 0.9) of a tokamak, the radial electric field and its shear are dominated by toroidal rotation. The fundamental quantity for shear stabilization of microturbulence is shear in the velocity of the fluctuations v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#E_rxB/B#centre dot#B which in the core is v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#v_#phi#B_#theta#/ B_#phi#. With magnetic braking greatly decreasing the toroidal rotation and thus reducing the core radial electric field and shear, far infrared (FIR) measurements of density microturbulence show downshifting in frequency near #rho##approx#0.8 as a result of the reduced Doppler shift ...

400

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.  

DEFF Research Database (Denmark)

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global stimulation, ...

2004-01-01

401

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were ...

2011-09-01

402

Analytical model for the dynamic resistivity of electrically-exploded conductors  

Science.gov (United States)

A detailed model for the dynamic resistivity of an exploding conductor presents many difficulties. An electrically-exploded conductor undergoes significant hydrodynamic expansion as it is heated. Resistivity is a function of both the temperature and density of a conductor and realistic models for resistivity over the range of parameter space experienced by an exploding conductor are quite complex. See for example, the model of Lee and More (1984). Calculation of the hydrodynamic expansion of the conductor during and subsequent to the explosion is likewise dependent on detailed knowledge of the equation of state for the conductor in a range where few experimental data exist. A further complication is the strong magnetic field which couples the hydrodynamic expansion to the currents flowing in the expanding material. In spite of the difficulties, progress is being made on detailed ...

1986-10-10

403

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

405

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

406

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

407

R and D for a single-layer Nb{sub 3}Sn common coil dipole using the react-and-wind fabrication technique  

Energy Technology Data Exchange (ETDEWEB)

A dipole magnet based on the common coil design, using prereacted Nb{sub 3}Sn superconductor, is under development at Fermilab, for a future Very Large Hadron Collider. This magnet has some innovative design and technological features such as single layer coils, a 22 mm wide 60-strand Rutherford type cable and stainless steel collars reinforced by horizontal bridges inserted between coil blocks. Both left and right coils are wound simultaneously into the collar structure and then impregnated with epoxy. In order to optimize the design and fabrication techniques an R&D program is underway. The production of cables with the required characteristics was shown possible. Collar laminations were produced, assembled and tested in order to check the effectiveness of the bridges and the validity of the mechanical design. A mechanical model consisting of a 165 mm long section of the magnet straight ...

2002-01-14

408

Images of very high energy cosmic ray sources in the Galaxy: I. A source towards the galactic centre  

Energy Technology Data Exchange (ETDEWEB)

Recent analyses of the anisotropy of cosmic rays at 10{sup 18} eV (the AGASA and SUGAR data) show significant excesses from regions close to the galactic centre and Cygnus. Our aim is to check whether such anisotropies can be caused by single sources of charged particles. We investigate propagation of protons in two models of the galactic regular magnetic field (with the irregular component included) assuming that the particles are injected by a short-lived discrete source lying in the direction of the galactic centre. We show that apart from a prompt image of the source, the regular magnetic field may cause delayed images at quite large angular distances from the actual source direction. The image is strongly dependent on the time elapsed after ejection of particles and it is also very sensitive to their energy. For the most favourable conditions for particle acceleration by a young pulsar, the predicted fluxes are two to ...

2002-08-01

409

Field-induced valence transition of Eu(Pd{sub 1{minus}x}Pt{sub x}){sub 2}Si{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The magnetic susceptibility and high-field magnetization have been measured for the intermediate valence system Eu(Pd{sub 1{minus}x}Pt{sub x}){sub 2}Si{sub 2} with 0{le}x{le}0.15. A first-order valence transition is observed for all the compounds under high field of 100 T at low temperatures. This valence transition is of first order accompanied with a large hysteresis, which is in contrast to a continuous valence change against temperature. Based on the interconfigurational fluctuation (ICF) model, the temperature- and field-induced valence transitions are discussed. It is found that a first-order valence transition can be induced by magnetic field, even if the system shows a continuous valence transition against temperature. Metamagnetic behavior at finite temperatures is also understood qualitatively by the ICF model. {copyright} {ital 1997} {ital The American Physical Society}

1997-05-01

410

TeV gamma-rays from the Northern sky pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We estimate the TeV {gamma}-ray fluxes expected from the population of young pulsars in terms of the self-consistent time-dependent hadronic-leptonic model for the high-energy processes inside the pulsar wind nebulae (PWNe). This radiation model is based on the hypothesis of Arons and collaborators who postulate that leptons are accelerated inside the nebulae as a result of resonant scattering on heavy nuclei, which in turn are accelerated in the pulsar wind region or the pulsar inner magnetosphere. Our aim is to find out which PWNe on the northern hemisphere are the best candidates for detection at energies above 60 GeV and 200 GeV by the next generation of low-threshold Cherenkov telescopes.

2005-12-01

411

Study of the $pp \\to np\\pi^+$ reaction at 1.25 GeV with HADES  

CERN Document Server

In pp collisions at 1.25 GeV kinetic energy, the HADES collaboration aimed at investigating the di-electron production related to $\\Delta$ (1232) Dalitz decay ($\\Delta^+ \\to pe^+e^-$). In order to constrain the models predicting the cross section and the production mechanisms of $\\Delta$ resonance, the hadronic channels have been measured and studied in parallel to the leptonic channels. The analyses of $pp\\to np\\pi^+$ and $pp\\to pp\\pi^0$ channels and the comparison to simulations are presented in this contribution, in particular the angular distributions being sensitive to $\\Delta$ production and decay. The accurate acceptance corrections have been performed as well, which could be tested in all the phase space region thanks to the high statistic data. These analyses result in an overall agreement with the one-$\\pi$ exchange model and previous data.

2009-01-01

412

Forced vibration tests on three types of embedded structures (embedment effect test on soil-structure interaction)  

International Nuclear Information System (INIS)

A series of Model Tests of Embedment Effect on Reactor Buildings has been carried out by the Nuclear Power Engineering Corporation (NUPEC), under the sponsorship of the Ministry of International Trade and Industry (MITI) of Japan. Sinusoidal forced vibration tests were carried out on three types of large-scale models to study the embedment effect on dynamic soil-structure interaction. The differences in the resonance curves and the impedance functions were discussed in relation to the vibration characteristics of the respective structures. The embedment effects on the structural responses vary according to the stiffness of the structure. The responses of the structures can be evaluated by the Axisymmetric FEM analyses. (author)

1993-08-15

413

A neutrino-nucleon interaction generator for the FLUKA Monte Carlo code  

CERN Document Server

Event generators that handle neutrino-nucleon interaction have been developed for the FLUKA code [1]. In earlier FLUKA versions only quasi-elastic (QEL) interactions were included, and the code relied on external event generators for the resonance (RES) and deep inelastic scattering (DIS). The new DIS+RES event generator is fully integrated in FLUKA and uses the same hadronization routines as those used for simulating hadron-nucleon interactions. Nuclear effects in neutrino-nucleus interactions are simulated within the same framework as in the FLUKA hadron-nucleus interaction model (PEANUT), thus profiting from its detailed physics modelling and longstanding benchmarking. The generators are available in the standard FLUKA distribution. They are presently under development and several improvements are planned to be implemented. The physics relevant to the neutrino-nucleon interactions and the results of comparisons with ...

2010-01-01

414

From Sakata Model to Goldberg-Ne'eman Quarks and Nambu QCD Phenomenology and "Right" and "Wrong" experiments  

CERN Document Server

The basic theoretical milestones were the Sakata SU(3) symmetry, the Goldberg-Ne'eman composite model with SU(3) triplets having baryon number (1/3) and the Nambu color gauge Lagrangian. The transition was led in right and wrong directions by experiments interpreted by phenomenology. A "good" experiment on $\\bar p p$ annihilation at rest showed that the Sakata model predictions disagreed with experiment. A "bad" experiment prevented the use of the Goldberg-Ne'eman triplet model to predict the existence and masses of the of the $\\Xi^*$ and $\\Omega^-$. More "good" experiments revealed the existence and mass of the $\\Xi^*$ and the $\\Omega^-$ and the absence of positive strangeness baryon resonances, thus confirming the "tenfold way". Further "good experiments" revealed the existence of the vector meson nonet, SU(3) breaking with singlet-octet mixing and the suppression of the $\\phi \\to \\rho \\pi$ ...

2007-01-01

415

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The process is observed to be dominated by the production and decay of natural spin-parity ...

1988-11-01

416

Gyrokinetic particle simulation model  

Energy Technology Data Exchange (ETDEWEB)

A new type of particle simulation model based on the gyrophase-averaged Vlasov and Poisson equations is presented. The reduced system, in which particle gyrations are removed from the equations of motion while the finite Larmor radius effects are still preserved, is most suitable for studying low frequency microinstabilities in magnetized plasmas. It is feasible to simulate an elongated system (L/sub parallel/ >> L/sub perpendicular/) with a three-dimensional grid using the present model without resorting to the usual mode expansion technique, since there is essentially no restriction on the size of ..delta..x/sub parallel/ in a gyrokinetic plasma. The new approach also enables us to further separate the time and spatial scales of the simulation from those associated with global transport through the use of multiple spatial scale expansion. Thus, the model can be a very efficient tool for studying ...

1986-07-01

417

The magnetopause  

Energy Technology Data Exchange (ETDEWEB)

A review of theoretical and observational research on the magnetopause during 1987-1990. Starting with recent work on magnetic reconnection, the review proceeds to magnetopause surface wave phenomena, including the controversy over the role of solar wind pressure pulses in the coupling process and in the mimicking of flux transfer events signatures, and finishes with the magnetopause structure and associated wave phenomena. Recent advances in computer modeling of the magnetopause and the pertinent processes are also discussed. 108 refs.

1991-01-01

418

Plasma Flow Equilibrium, Confinement Scaling Laws and Fusion Prospects of a Field Reversed Configuration  

International Nuclear Information System (INIS)

Field reversed configuration (FRC) is a prospective high ? magnetic system for high efficiency D- 3He fusion reactor. Self-consistent FRC plasma profiles and static electric field for reactor calculations are discussed in framework of the model including flow equilibrium and collisionless transport equations. The extrapolations to reactor regimes of plasma confinement scaling laws are considered.

2006-01-01

419

On the Uniqueness of Solutions of a Nonlinear Elliptic Problem Arising in the Confinement of a Plasma in a Stellarator Device  

International Nuclear Information System (INIS)

We study the uniqueness of solutions of a semilinear elliptic problem obtained from an inverse formulation when the nonlinear terms of the equation are prescribed in a general class of real functions. The inverse problem arises in the modeling of the magnetic confinement of a plasma in a Stellarator device. The uniqueness proof relies on an L"#infinity# -estimate on the solution of an auxiliary nonlocal problem formulated in terms of the relative rearrangement of a datum with respect to the solution.

420

Loss of light charged particles by nuclear interactions in BaF[sub 2] crystals  

Energy Technology Data Exchange (ETDEWEB)

The nuclear interaction probability of light charged particles in BaF[sub 2] crystals has been studied as a function of the incident particle energy. Light charged particles were identified in charge and mass by measuring their magnetic rigidity and their time-of-flight. The percentage of particles undergoing nuclear interactions has been measured for particles of charge from Z=1 to Z=6 and the experimental data are compared with the results of a model calculation. (orig.)

1993-07-15

421

Local Quark-Hadron Duality and Magnetic Form Factors of Bound Proton  

International Nuclear Information System (INIS)

We discuss the consequence of local duality for elastic scattering, and derive a model-independent equation between structure functions at x ? 1 and elastic electromagnetic form factors. Then the electromagnetic form factors of proton are discussed using the quark-hadron duality theory. We also debate the form factor of proton in a bound state. It may be an effective approach to study the form factor of proton in media.

2005-08-01

422

Investigation of lifetimes in the dipole band of {sup 139}Sm  

Energy Technology Data Exchange (ETDEWEB)

Lifetimes have been measured for a dipole band in {sup 139}Sm using DSAM. The deduced B(M1) and B(E2) values as well as B(M1)/B(E2) ratios are compared with calculations in the framework of the TAC (Tilted Axis Cranking) and SPAC (Shears mechanism with Principal Axis Cranking) models. The dipole band in {sup 139}Sm can be considered as a magnetic rotational band with a prolate or triaxial nuclear deformation. (orig.)

2008-09-15

423

Investigation of lifetimes in dipole bands of {sup 142}Gd  

Energy Technology Data Exchange (ETDEWEB)

Lifetimes have been measured for dipole bands in {sup 142}Gd using DSAM. The deduced B(M1) and B(E2) values as well as B(M1)/B(E2) ratios are compared with calculations in the framework of the TAC (Tilted Axis Cranking) and SPAC (shears mechanism with Principal Axis Cranking) models. The dipole bands DB1 to DB4 can be interpreted as magnetic rotational bands. (orig.)

2005-02-01

424

Fusion technology  

International Nuclear Information System (INIS)

The Fusion Technology task performs analyses and systems studies of conceptual fusion reactors based upon inertial and high-#beta# magnetic confinement schemes. Progress in the areas of theoretical analysis (plasma and neutral-gas blanket models), specific reactor studies (toroidal and linear theta pinches, Z pinches, laser fusion) neutronic and nuclear data assessments, materials (metals and insulators) evaluation, and general engineering design is reported.

1976-12-01

425

Dynamical evolution and molecular abundances of interstellar clouds  

International Nuclear Information System (INIS)

Dynamical models are presented that start with interstellar gas in an initial diffuse state and consider their gravitational collapse and the formation of dense cores. Frozen-in tangled magnetic fields are included to mimic forces that might oppose gravitational contraction and whose effectiveness may increase with increasing core densities. Results suggest the possibility that dense cloud cores may be dynamically evolving ephemeral objects, such that their lifespan at a given core density decreases as that density increases. 66 refs.

426

Four pion decay modes of the f{sub 0}(1500) resonance; Modes de desintegration de la resonance f{sub 0}(1500) en 4 pions  

Energy Technology Data Exchange (ETDEWEB)

We investigate the two-body decay modes {rho}{rho}, {pi}{pi}{sup *} (1300) and {sigma}{sigma} of the f{sub 0}(1500), all leading to the four pion decay channel, in a three-state mixing scheme, where the f{sub 0}(1500) is a mixture of the lowest lying scalar glueball with the nearby isoscalar states of the 0{sup ++}Q Q-bar nonet. In the leading order of this scheme, the decay mechanism of the f{sub 0}(1500) proceeds dominantly via its quarkonium components, which can be described in the framework of the {sup 3}P{sub 0} pair creation model. We predict the hierarchy of decay branching ratios B with B({rho}{rho}) {>=} B({pi}{pi}) {>=} B({sigma}{sigma}) > B({pi}{pi}{sup *}), providing a key signature of the proposed mixing scheme in this leading order approach. (authors)

1999-10-01

427

Separation of variables for the quantum SL(2,R) spin chain  

CERN Document Server

We construct representation of the Separated Variables (SoV) for the quantum SL(2,R) Heisenberg closed spin chain and obtain the integral representation for the eigenfunctions of the model. We calculate explicitly the Sklyanin measure defining the scalar product in the SoV representation and demonstrate that the language of Feynman diagrams is extremely useful in establishing various properties of the model. The kernel of the unitary transformation to the SoV representation is described by the same "pyramid diagram" as appeared before in the SoV representation for the SL(2,C) spin magnet. We argue that this kernel is given by the product of the Baxter Q-operators projected onto a special reference state.

2003-01-01

428

Polaron model of the electronic spectrum and the superconductivity of compounds having the A-15 structure  

Energy Technology Data Exchange (ETDEWEB)

The existence of a narrow peak in the electronic density of states in A-15 compounds is explained by a strong electron--phonon interaction that leads to the polaron narrowing of the band. An analytic expression relating the transition temperature T/sub c/ to the phonon spectrum is derived under the assumption of a weak and an intermediate-strength coupling. The model allows the explanation of the correlation of T/sub c/ with the number of electrons per atom, the temperature dependence of the resistance, the magnitude and temperature dependence of the magnetic susceptibility, and the electronic specific heat.

1983-02-01

429

Nonlinear time-domain modeling of balanced-armature receivers  

DEFF Research Database (Denmark)

Nonlinear distortion added by the loudspeaker in a hearing aid lowers the signal-to-noise ratio and may degrade the hearing aid user's ability to understand speech. The balancedarmature- type loudspeakers, predominantly used in hearing aids, are inherently nonlinear devices, as any displacement of the loudspeaker diaphragm inevitably changes the magnetic and electrical characteristics of the loudspeaker. A numerical time-domain model capable of describing these nonlinearities is presented. By simulation it is demonstrated how the output distortion could potentially be reduced significantly through careful design of the mechanical properties of the armature.

2011-01-01

430

Initial results from 50mm short SSC dipoles at Fermilab  

Energy Technology Data Exchange (ETDEWEB)

Several short model SSC 50 mm bore dipoles are being built and tested at Fermilab. Mechanical design of these magnets has been determined from experience involved in the construction and testing of 40 mm dipoles. Construction experience includes coil winding, curing and measuring, coil end part design and fabrication, ground insulation, instrumentation, collaring and yoke assembly. Fabrication techniques are explained and construction problems are discussed. Similarities and differences from the 40 mm dipole tooling and management components are outlined. Test results from the first models are presented. 19 refs., 12 figs.

1991-03-01

431

A new calculation of the cosmic-ray antiproton spectrum in the Galaxy and heliospheric modulation effects on this spectrum using a drift plus wavy current sheet model  

Energy Technology Data Exchange (ETDEWEB)

The expected interstellar antiproton spectrum arising from cosmic-ray interactions in the Galaxy is recalculated, and the modulation of both antiprotons and protons is calculated using a two-dimensional modulation model incorporating gradient and curvature drifts and a wavy current sheet as well as the usual diffusion, convection, and energy-loss effects. Significant differences in the antiproton/proton ratio for different solar magnetic field polarities are predicted as well as a 'low-energy' component for antiprotons below about 1 GeV. 28 refs.

1989-09-01

432

Modelling of density limit phenomena in toroidal helical plasmas  

Energy Technology Data Exchange (ETDEWEB)

The physics of density limit phenomena in toroidal helical plasmas based on an analytic point model of toroidal plasmas is discussed. The combined mechanism of the transport and radiation loss of energy is analyzed, and the achievable density is derived. A scaling law of the density limit is discussed. The dependence of the critical density on the heating power, magnetic field, plasma size and safety factor in the case of L-mode energy confinement is explained. The dynamic evolution of the plasma energy and radiation loss is discussed. Assuming a simple model of density evolution, of a sudden loss of density if the temperature becomes lower than critical value, then a limit cycle oscillation is shown to occur. A condition that divides the limit cycle oscillation and the complete radiation collapse is discussed. This model seems to explain the density limit oscillation that has been observed on the W7-AS ...

2000-03-01

433

Galactic Cosmic Rays - Clouds Effect and Bifurcation Model of the Earth Global Climate. Part 1. Theory  

CERN Document Server

The possible physical linkage between galactic cosmic rays intensity and the Earth's cloud cover is discussed using the analysis of the first indirect aerosol effect (Twomey effect) and its experimental representation as the dependence of average cloud droplet effective radius on aerosol index characterizing the aerosol concentration in the atmospheric air column of unit section. It is shown that the basic kinetic equation of the Earth's climate energy-balance model is described by the bifurcation equation (with respect to the temperature of the Earth's surface) in the form of fold catastrophe with two governing parameters defining the variations of insolation and Earth's magnetic field (or galactic cosmic rays intensity in the atmosphere), respectively. The principle of hierarchical climatic models construction, which consists in the structural invariance of balance equations of these models evolving ...

2008-01-01

434

Visualization and volumetric structures from MR images of the brain  

Energy Technology Data Exchange (ETDEWEB)

Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet ...

1994-03-01

435

Thermodynamic and kinetic aspects of surface acidity  

Science.gov (United States)

Our research in the general area of acid catalysis involves the characterization of solid acidity and the corresponding assessment of catalytic performance of acidic materials. Acid characterization studies are required to provide essential information about the type of acid site (i.e., Lewis versus Bronsted), the strength of the sites, and the mobility of molecules adsorbed on the acid sites. An accurate measure of acid strength is given by the heat of adsorption of a basic probe molecule on the acid site. A thermodynamic representation of the mobility of adsorbed species on these sites is given by the entropy of adsorption. Important techniques used in these acid site characterization studies include microcalorimetry, thermogravimetric measurements, temperature programmed desorption, infrared spectroscopy and solid state nuclear magnetic resonance. The combination of these acid site characterization studies with reaction kinetics measurements ...

1992-01-01

436

Surgery for acoustic neurinoma treated by gamma-knife radiosurgery. A case report  

Energy Technology Data Exchange (ETDEWEB)

A 52-year-old woman had a history of left hearing loss for 5 years. An acoustic neurinoma with 3.2 cm in diameter was diagnosed and treated with gamma-knife radiosurgery (19 Gy of marginal dose) 1 year and 4 months ago. She developed headache, nausea, and visual disturbance 1 month prior to admission. Slight left facial palsy appeared after radiosurgery. Magnetic resonance imaging demonstrated the tumor with central necrosis in the left cerebellopontine angle cistern, increasing in size to 3.5 cm in diameter, and hydrocephalus. Tumor removal was performed incompletely, because of the fibrous appearance of the tumor and severe adherence with the surrounding cerebellar tissue. Facial palsy did not worsen after surgery. Since the hydrocephalus was not resolved, a right ventriculo-peritoneal shunt was inserted. The clinical course in this case suggests that tumor removal followed by radiosurgery was an approximately effective treatment for large ...

2001-08-01

437

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li{sub 2}S-SiS{sub 2}-Li{sub 3}PO{sub 4} Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li{sub 2}S{center_dot}0.4SiS{sub 2})centre dotxLi{sub 3}PO{sub 4} oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO{sub n}S{sub 4-n} (n=1,2,3) and PO{sub n}S{sub 4-n} (n=1,2,3) present in the glass samples vanished and the SiS{sub 4}, PS{sub 4}, SiO{sub 4} units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S{sup 2-} increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

438

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li[sub 2]S-SiS[sub 2]-Li[sub 3]PO[sub 4] Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li[sub 2]S[center dot]0.4SiS[sub 2])centre dotxLi[sub 3]PO[sub 4] oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO[sub n]S[sub 4-n] (n=1,2,3) and PO[sub n]S[sub 4-n] (n=1,2,3) present in the glass samples vanished and the SiS[sub 4], PS[sub 4], SiO[sub 4] units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S[sup 2-] increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

439

Sorption equilibrium and hydration studies of lysozyme: water activity and 360-MHz proton NMR measurement  

International Nuclear Information System (INIS)

An attempt to determine lysozyme hydration by employing a proton nuclear magnetic resonance (NMR) spin-echo technique and to correlated such measurements with the 20 "0C sorption equilibrium data is made. Determinations of specific site hydration for lysozyme, as well as proton NMR transverse relaxation rates for five different types of water populations in the lysozyme-water system, are presented over the whole range of lysozyme concentrations. The proton spin-echo NMR results are consistent with a three-component analysis of the sorption isotherm up to 70% water content, above which two additional water populations are identified by 360-MHz proton NMR spin-echoes. On the basis of the proton NMR results, a major component (III) of the lysozyme sorption isotherm is assigned to the water trapped between lysozyem molecules, whose relaxation rate is increased by diffusion barriers. The trapped water population dominates the relationship between ...

440

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After surgical treatment, the ...

441

Sol-gel coatings with phosphonate functionalities for surface modification of magnesium alloys  

International Nuclear Information System (INIS)

Hybrid organic-inorganic coatings with phosphonate functionalities have been synthesized and evaluated as prospective surface treatments for magnesium materials. These coatings have been processed via a sol-gel route by hydrolysis and condensation of a mixture of diethylphosphonatoethyltriethoxy-silane and tetraethoxy-silane with variable molar ratios. The coatings morphology and the surface chemistry at the coating/substrate interface have been characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, "3"1P nuclear magnetic resonance spectroscopy, and time-of-flight secondary ion mass spectrometry. The corrosion protection performance of the coatings deposited on magnesium alloy AZ31B has been examined by a group of electrochemical techniques including potentiodynamic polarization and electrochemical impedance spectroscopy. In addition, a scanning Kelvin probe technique has been used to investigate interfacial ...

2006-08-30

442

Soft tissue manifestations of early rheumatic disease. Imaging with MRI  

International Nuclear Information System (INIS)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a ...

2006-08-01

443

Potential anti fungal agents. Synthesis and activity of 2-alkylthiopyridine-4-carbothioamides  

Energy Technology Data Exchange (ETDEWEB)

A series of 2-alkylthiopyrine-4-carbothioamides were synthesized, and their anti-fungal potency was tested. The chemical structures were proved by infrared spectroscopy (IR) and {sup 1}H nuclear magnetic resonance ({sup 1}H-NMR) data and by elemental analysis. The minimal inhibitory concentration (MIC) and minimal fungicidal concentration (MFC) assessment were used for the estimation of potential activity in vitro. The study comprising 21 clinical isolates of fungi showed that two compounds exhibited fair inhibitory activity against some yeasts and dermatophytes. Selective fungistatic activity against non-dermatophytes (MIC = 3.12-25.0 {mu}g/mL) was found also in another compound. None of the above compounds showed inhibitory activity against non-dermatophyte filamentous fungi. Microbiological activity of 2-alkylthiopyridine-4-carbothioamides appears to be mainly related to hydrophobicity of alkyl in position 2. (authors). 10 refs., 8 tabs.

1996-05-01

444

Novel non-discoid chiral copper(II)-salen type [N2O2] donor Schiff base complexes with a cyclohexane diamine spacer: synthesis, electrochemistry, columnar mesomorphism and DFT study  

British Library Electronic Table of Contents (United Kingdom)

A series of new non-discoid chiral copper(ii)-salen type complexes, [Cu((4-CnH2n+1O)2salen)], n = 14, 16, 18 and salen = N,N'-cyclohexane bis (salicylideneiminato), containing 4-substituted alkoxy tails in the side aromatic rings and a cyclohexane spacer, have been prepared and their mesogenic properties investigated. The compounds were characterised by Fourier transform infra-red spectroscopy, 1H and 13C nuclear magnetic resonance spectroscopy, UV-vis spectroscopy and fast atom bombardment mass spectrometry. Mesomorphic properties of these compounds were studied by polarising optical microscopy, differential scanning calorimetry and X-ray diffraction (XRD). The ligands are non-mesogenic but the complexes exhibited enantiotropic rectangular columnar mesophases (Colr) with extended temperat...

2011-01-01

445

Normal and abnormal water diffusion in the brain  

International Nuclear Information System (INIS)

Diffusion magnetic resonance imaging (MRI) has become an important tool in the radiologic diagnosis of diseases of the brain as it measures molecular motion of water that characterizes the microstructure of tissues. Its most important clinical use to date is the early detection of cerebral ischemia by revealing the ischemic injury shortly after vessel occlusion and simultaneously providing therapy-relevant information on the tissue at risk. Furthermore, diffusion MRI is diagnostically promising in other diseases of the brain and is thus increasingly becoming part of routine clinical protocols in the diagnosis of tumors, inflammation, trauma, demyelination, dysmyelination and neurodegeneration. Although abnormalities of diffusion are generally not pathognomonic, diffusion MRI affords information about tissue changes for specific disorders that complements information obtained with standard MR techniques and frequently shows pathology earlier. In ...

2003-10-01

446

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D ...

2008-04-15

447

Mechanism of adenylate kinase. Dose adenosine 5'-triphosphate bind to the adenosine 5'-monophosphate site  

Energy Technology Data Exchange (ETDEWEB)

Although the subtrate binding properties of adenylate kinase (AK) have been studied extensively by various biochemical and biophysical techniques, it remains controversial whether uncomplexed adenosine 5'-triphosphate (ATP) binds to the adenosine 5'-monophosphate (AMP) site of AK. The authors present two sets of experiments which argue against binding of ATP to the AMP site. (a) /sup 31/P nuclear magnetic resonance titration of ATP with AK indicated a 1:1 stoichiometry on the basis of changes in coupling constants and line widths. This ruled out binding of ATP to both sites. (b) ATP and MgATP were found to behave similarly by protecting AK from spontaneous inactivation while AMP showed only a small degree of protection. Such inactivation could also be protected or reversed by dithioerythritol and is most likely due to oxidation of sulfhydryl groups, one of which (cysteine-25) is located near the MgATP site. The results support ...

1987-10-06

448

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der Darstellung der Meningitis beobachtet. Eine ...

1994-12-31

449

MRS of normal and impaired fetal brain development  

International Nuclear Information System (INIS)

Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are ...

2006-02-01

450

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. Contrast MRI study is ...

451

Longitudinal and transverse dynamics of a free electron laser based on a storage ring of second and third generation  

International Nuclear Information System (INIS)

This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a modulation, the FEL can present a periodic or chaotic regime. The ...

452

Kinetic studies of preactivated derivatives of cyclophosphamide by "3"1P NMR spectroscopy  

International Nuclear Information System (INIS)

Selected derivatives of cyclophosphamide (CP) metabolites were synthesized and the solution chemistry of each was studied by "3"1P nuclear magnetic resonance (NMR) spectroscopy under a standard set of reaction conditions at physiological pH (7.4) and temperature (37"0C). Complementary "2H and "1"3C NMR spectral data was obtained using isotopically ("2G and "1"3C) enriched CP metabolites. The CP derivatives were synthesized by the ozonolysis of substituted 3-butenyl phosphorodiamidates, and were isolated as analogues of either cis and trans 4-hydroperoxy-CP or aldophosphamide (AP). The relative ratios of the tautomeric species, 4-hydroxy-CP and AP, and their half-lives (T/sub 1/2/) were measured by "3"1P NMR spectroscopy. The influence of CP metabolites on perfused U-937 cells, a CP-sensitive human lymphoma, was observed by high resolution "3"1P NMR spectroscopy. In this manner, it was possible to measure, for the first time, a rate constant for ...

453

Interaction of cis-diamminediaquoplatinum(II) with adenosylcobalamin and alkylcobalamins  

Energy Technology Data Exchange (ETDEWEB)

The interaction of cis-diamminediaquoplatinum(II) nitrate with adenosylcobalamin and a series of alkylcobalamins was studied by carbon-13 nuclear magnetic resonance spectroscopy and by electronic spectroscopy. With these cobalamins cis-(Pt(NH/sub 3/)/sub 2/(OH/sub 2/)/sub 2/)/sup 2 +/ forms adducts in which N(3) of the 5,6-methylbenzimidazole moiety is co-ordinated to platinum(II) rather than to cobalt(III) of the corrin. The chemical shifts of the 5'-methylene carbon of adenosylcobalamin-platinum adduct and of the Co-methyl carbon of the methylcobalamin-platinum adduct are characteristic of these cobalamins in the base-off form. Furthermore, these cobalamin-platinum complexes have visible spectra identical to those of the cobalamins in acidic solution. The /sup 13/C NMR spectrum of the adenosylcobalamin-platinum complex suggests the presence of a second adduct in which platinum(II) complexes are co-ordinated to both the N(3) of the ...

1980-01-01

454

In vivo phosphorylation of histones H1 and H5 in calf thymus and chicken erythrocytes as studied by /sup 31/P nuclear magnetic resonance spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The /sup 31/P NMR method was first applied to characterize in vivo phosphorylation of H1 and H5 in calf thymus and chicken erythrocytes as well as in vitro phosphorylation of H1 and H5 by cAMP-dependent protein kinase. The amino acid residues phosphorylated in vivo in the histones were exclusively serine residues, and the mole fraction of phosphoserine was estimated to be 0.34 and 0.27 per molecule of calf thymus H1 and chicken erythrocyte H5, respectively. Interestingly, chicken erythrocyte H1 was not phosphorylated in vivo. Three H1 subtypes from calf thymus H1 varied in the /sup 31/P NMR spectra, and the bisected fragments of calf thymus H1 and chicken erythrocyte H5 exhibited characteristic spectral patterns, indicating that there are considerable diversities of the degree of phosphorylation and phosphorylation sites in very-lysine-rich histones. Furthermore, it was found that the microenvironment of phosphoserine residues phosphorylated in vivo in calf thymus H1 and chicken ...

1987-08-01

455

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium ...

1998-06-01

456

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

457

Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis.  

DEFF Research Database (Denmark)

The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly to both the results of the contrast sensitivity test ...

2002-01-01

458

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences  

International Nuclear Information System (INIS)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of ...

459

Enzymatic synthesis and carbon-13 nuclear magnetic resonance conformational studies of disaccharides containing #beta#-D-galactopyranosyl and #beta#-D-[1-"1"3C]Galactopyranosyl residues  

International Nuclear Information System (INIS)

Partially purified UDPgalactosyltransferase (EC 2.4.1.22) from bovine milk has been used to synthesize millimolar amounts of compounds such as Gal#beta#(1#->#4)Glc, Gal#beta#(1#->#4)GlcNAc-#beta#-hexanolamine, and Gal#beta#(1#->#4)-GlcNAc#beta#(1#->#4)GlcNAc. The same method has been used to prepare similar compounds containing "1"3C-enriched galactopyranosyl moieties. Gal#beta#(1#->#4)GlcNAc-#beta#-hexanolamine was also synthesized in a solid-phase system in which the GlcNAc-#beta#-hexanolamine glycoside was covalently linked to agarose beads. At pH 7.0 and at 1 to 5 mM Mn"2"+"+ the yields of the galactosyl saccharides are greater than 90% by using 10% excess of UDPGal donor. The use of a 90% enriched [1-"1"3C]galactosyl residue allowed the determination of the most abundant conformer about the galactopyranosyl-glycoside linkage by analysis of the carbon-carbon coupling constants from Cl to Gal to the C3', C4', and C5' of GlcNAc or Glc. 3 figures, 1 table.

460

Effect of external pH on the cytoplasmic and vacuolar pHs in Mung bean root-tip cells  

International Nuclear Information System (INIS)

The effect of the external pH on the intracellular pH in mung bean (Vigna mungo (L.) Hepper) root-tip cells was investigated with the "3"1P nuclear magnetic resonance (NMR) method. The "3"1P NMR spectra showed three peaks caused by cytoplasmic G-6-P, cytoplasmic Psub(i) and vacuolar Psub(i). The cytoplasmic and vacuolar pHs could be determined by comparing the Psub(i) chemical shifts with the titration curve. When the external pH was changed over a range from pH 3 to 10, the cytoplasmic pH showed smaller changes than the vacuolar pH, suggesting that the former is regulated more strictly than the latter. The H"+-ATPase inhibitor, DCCD, caused the breakdown of the mechanism that regulates the intracellular pH. H"+-ATPase appears to have an important part in the regulation of the intracellular pH. (author).

461

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...

462

Diagnostic difficulties in extraosseous Ewing's sarcoma: A proposal for diagnostic criteria  

International Nuclear Information System (INIS)

Five cases diagnosed as extraosseous Ewing's sarcoma (EES) during a 15 year period, and the relevant literature, were reviewed. The diagnosis in these cases was difficult to confirm, mainly because the distinction between the osseous form of Ewing's sarcoma (OES) and either periosteal reactions or direct tumour invasion into adjacent bone by EES was often unclear. The literature suggests that other authors have also encountered difficulties. The authors believe that many cases reported as EES are likely to have been OES. This distinction has some importance, as the two conditions are usually treated in differing ways. The following criteria are proposed for the diagnosis of primary EES: (i) no evidence of bony involvement on magnetic resonance imaging; (ii) no evidence of increased uptake in bone or periosteum adjacent to the tumour on static isotope bone scan images; (iii) a small round cell tumour with no differentiating features on light ...

463

Crystal growth, structural and optical characterization of a semi-organic single crystal for frequency conversion applications  

International Nuclear Information System (INIS)

Single crystals of semi-organic L-histidine hydrobromide have been grown by slow evaporation technique from a mixture of L-histidine and hydrobromic acid in aqueous solution at ambient temperature. From high-resolution X-ray diffraction analysis, the crystalline perfection of the grown crystal has been studied. Single crystal X-ray diffraction analyses, Nuclear Magnetic Resonance spectral analysis, Thermo-Gravimetry (TG), Differential Thermal Analysis (DTA) and hardness test have been employed to characterize the as-grown crystals. The UV cutoff wavelength of the grown crystal is below 300 nm and has a wide transparency window, which is suitable for second harmonic generation of laser in the blue region. Nonlinear optical characteristics have been studied using Q switched Nd:YAG laser (#lambda#=1064 nm). The second harmonic generation conversion efficiency of the grown crystals confirms their suitability for frequency conversion applications.

2010-12-15

464

Consolidated silica glass from nanoparticles  

International Nuclear Information System (INIS)

A dense silica glass was prepared by consolidating a highly dispersed silicic acid powder (particle size 1H magic-angle spinning (MAS) NMR confirmed an increase in hydroxyl groups in the sample prepared by SPS relative to that of the conventional SiO2 reference glass. Aside from the comparably high water content, we conclude from the similarity of the IR-reflectance and the 29Si MAS NMR spectra of the SPS sample and the corresponding spectra of the conventionally prepared silica glass, that the short- and medium-range order is virtually the same in both materials. Raman spectroscopy, however, suggests that the number of three- and four-membered rings is significantly smaller in the SPS sample compared to the conventionally prepared sample. Based on these results we conclude that it is possible to prepare glasses by compacting amorphous powders by the SPS process. The SPS process may therefore enable the preparation of glasses with compositions inaccessible by conventional methods. - ...

2008-09-01

465

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and cerebello-pontine angle. HRCT best depicts osseous ...

2003-03-01

466

Characterization of systems active in selective catalytic reduction of NO{sub x}  

Energy Technology Data Exchange (ETDEWEB)

This thesis is in the field of gas emission control from automobile and stationary sources. Out of the possible approaches to the elimination of pollutant gases, such as nitrogen oxides (NO{sub x}), one consists in the selective catalytic reduction (SCR) of these NO{sub x} on a suitable heterogeneous catalyst. Ammonia or hydrocarbons are employed as reducing agents. The most important catalysts active in the SCR of NO{sub x} are based on ions of transition metal either supported on several oxides or dispersed in zeolites. The catalysts have been characterized by electron magnetic resonance techniques (EPR, ENDOR, ESEEM) and the interaction of catalysts with nitrogen oxides, with reducing and poisoned agents have been followed with the same techniques. Copper dispersed on alumina and its interaction with both NO and ammonia has been investigated. Also the interaction between both water and ammonia with copper dispersed in zeolite ZSM-5 has been ...

1998-06-01

467

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of PVNS and tendinitis ...

1988-01-01

468

CARM-klystron amplifier for accelerator applications  

International Nuclear Information System (INIS)

We consider the possibility of a cyclotron-autoresonance-maser (CARM) klystron configuration for accelerator applications as an alternative to the gyroklystron amplifier. The potential advantages, compared to gyroklystrons, include: 1) comparable efficiencies at lower values of the electron beam pitch ratio #alpha#, which should improve the beam quality and make the device substantially more stable against the excitation of parasitic mode, 2) operation far from cutoff, which should reduce the fields at cavity walls, allowing higher power operation, and 3) operation at lower magnetic fields for the same cyclotron harmonic number. However, there are two significant issues associated with the design of efficient, high-power CARMs. First, because of the higher value of k_Z, compared to gyroklystrons, CARMs are substantially more sensitive to parallel velocity spread (pitch-angle spread). Second, conventional cavities support a variety of near-cutoff modes, which can ...

2001-05-31

469

Beam-breakup calculations for the Los Alamos free-electron laser (FEL) linac  

International Nuclear Information System (INIS)

In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode acts to deflect the beam, and further assumes that this mode does not couple from one accelerating cavity to the next.

470

Application of spectroscopic techniques for the study of paper documents: A survey  

International Nuclear Information System (INIS)

For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear ...

2009-06-01

471

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...

1998-02-01

472

An availability of brain magnetic resonance imaging (MRI) in the early diagnosis of latent hepatic encephalopathy  

Energy Technology Data Exchange (ETDEWEB)

Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An improvement of this MRI finding was not observed by long-term oral administration of ...

1996-03-01

473

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research ...

2009-03-15

474

A fluorescent aminolipid from a green photosynthetic bacterium  

Energy Technology Data Exchange (ETDEWEB)

A preliminary chemical characterization is presented of phosphate-free aminolipids isolation from Chlorobium limicola f. thiosulfatophilum. The lipid contains no phosphorus, glycerol, sugar, ornithine, or lysine. Ultraviolet absorption and fluorescence spectra indicate that the amino moiety of the lipid is an aromatic heterocyclic compound. Infrared spectra indicate that the lipid is a secondary or tertiary amide, and gas chromatograhic analysis of the hydrolyzed lipid shows that for each 1100 g of lipid, 1 mol of myristic acid (C/sub 14:0/) is linked in an amide bond. Acid hydrolysis of the lipid yields two fluorescent substances, A (ninhydrine positive) and B (negative), in addition to myristic acid. Proton nuclear magnetic resonance (NMR) studies indicate that substance A contains a butyl groups attached to a conjugated ring carbon, two equivalent ethyl groups attached to one or two nitrogen atoms, and two downfield protons (8.4 ppm), ...

1983-04-12

475

#beta#-sialon via carbothermal reduction using brown coal  

International Nuclear Information System (INIS)

There has been a good deal of interest in the sialon system of ceramics in recent years due to their combination of important engineering properties #beta# including strength, hardness, low thermal expansion and good thermal shock resistance. #beta#-sialon (Si_6_-_zAl_zO_zN_8_-_z ;0Magnetic Resonance techniques in determining the nature of intermediate phases which occur. 9 refs., 1 tab., 1 fig.

476

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...

2003-05-01

477

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution in the z-axis. ...

2006-04-15

478

Electron cyclotron heating  

International Nuclear Information System (INIS)

Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented ...

479

Resonance Raman enhancement of phenyl ring vibrational modes in phenyl iron complex of myoglobin.  

UK PubMed Central (United Kingdom)

Resonance Raman spectra are reported for the organometallic phenyl-FeIII complexes of horse heart myoglobin. We observed the resonance enhancement of the ring vibrational modes of the bound phenyl group....Full Text Available

1990-04-01

480

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

Energy Technology Data Exchange (ETDEWEB)

Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

481

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

International Nuclear Information System (INIS)

Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

482

Interference phenomena at the elastic collision of atoms with formation of the Feshbach resonance in the presence of laser radiation field  

British Library Electronic Table of Contents (United Kingdom)

Resonant scattering of atoms with formation of the Feshbach resonance in the presence of a laser radiation coupling the levels of two bound atoms (a molecule) is considered. The laser field leads to a second resonance in scattering and broadening of resonances, which facilitates the possibility of experimental observation of asymmetry of the total scattering cross-section arising because of interference between resonant and potential scatterings. The effects associated with interference of the two channels of decay of a bound system of two atoms (a molecule) in the laser field are studied. An expression is obtained for the scattering length in collision of two cold atoms in the field of laser radiation.

2011-01-01

483

Wave formation mechanism in magnetic pulse welding  

British Library Electronic Table of Contents (United Kingdom)

Wavy interface morphology is observed in Magnetic Pulse Welding (MPW) similarly to that of the Explosion Welding process (EXW). It is recognized that interfacial waves are formed in a periodic manner and have well defined wavelength and amplitude. The phenomenon of wave formation in EXW has been subjected to extensive investigations in which empirical and numerical models have been published. In the present study, a wave formation mechanism for MPW is presented. This wave-creation mechanism was studied by evaluating the influence of sample geometry on wave morphology using stereoscopic optical microscopy. It was found that interfacial waves are formed in a Kelvin-Helmholtz instability mechanism. Reflected shock waves interact with the welding collision point at the weld interface, where in...

2010-01-01

484

Technique for the removal of electrons from an extracted, pulsed, H{sup {minus}} ion beam  

Energy Technology Data Exchange (ETDEWEB)

A small, permanent-magnet insert structure for the removal of electrons from pulsed, extracted, negative ion beams has been developed at Lawrence Berkeley National Laboratory. The device was computer modeled and designed for an extraction field strength of 3 kV/mm. The testing was carried out with a rf driven multicusp ion source optimized for the production of H{sup {minus}} ions and pulsed at a few Hz with pulse widths of several hundreds of {mu}s. It is demonstrated that the insert structure together with a collar can remove over 98{percent} of electrons from the extracted H{sup {minus}} ion beam without any significant deterioration of the H{sup {minus}} ion output. Application to other negative ion beams can be expected from this magnetic collar insert. {copyright} {ital 1996 American Institute of Physics.}

1996-10-01

485

Galaxy rotation curves: the effect of Formula Not Shown force  

British Library Electronic Table of Contents (United Kingdom)

Using the Galaxy as an example, we study the effect of Formula Not Shown force on the rotational curves of gas and plasma in galaxies. Acceptable model for the galactic magnetic field and plausible physical parameters are used to fit the flat rotational curve for gas and plasma based on the observed baryonic (visible) matter distribution and Formula Not Shown force term in the static MHD equation of motion. We also study the effects of varied strength of the magnetic field, its pitch angle and length scale on the rotational curves. We show that Formula Not Shown force does not play an important role on the plasma dynamics in the intermediate range of distances 6?12?kpc from the centre, whilst the effect is sizable for larger r (r?15?kpc), where it is the most crucial.

2011-01-01

486

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

487

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

488

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

489

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

490

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

492

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

493

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

495

Fault detection by Turam TEM survey. Numerical model studies and a case history; TEM ho Turam sokutei haichi ni yoru danso kenshutsu no kokoromi. Model keisan to jisshirei  

Energy Technology Data Exchange (ETDEWEB)

With an objective to detect faults estimated to exist along the Shigesumi valley in the Kamioka mine, discussions were given by using electromagnetic survey, which uses the Turam measurement arrangement based on the TEM method, and three-dimensional model calculations. The Turam measurement arrangement, which installs transmission loop fixedly, is used to identify nature and distribution of electrically conductive objects upon noticing abnormal portions in magnetic fields in the measurement data. In the model calculation, the plate model calculation method and the FDTD method were used, and so was the calculation code TEM3DL. The result revealed that strong topographical influence is seen from steep V-shaped valley existing along the traverse line in the measurement data, but an abnormal resistivity band accompanying remarkable distortion in the curve was detected. According to the result of the ...

1997-05-27

496

Inelastic electron scattering, M1 giant resonances and the quest for subnuclear degrees of freedom  

International Nuclear Information System (INIS)

... electrons fine structure giant resonance inelastic scattering iron 54 iron 54

1983-01-17

497

NMR of a synthetic peptide spanning the triphosphate binding site of adenosine 5'-triphosphate in actin  

Energy Technology Data Exchange (ETDEWEB)

The amino acid residues 114-118 in actin were found to be implicated strongly in the binding of nucleotide, and as would be expected for such an important binding site, they are located in a completely conserved region of the actin sequence. A 19-residue peptide with the actin sequence 106-124 was synthesized in order to span the putative triphosphate binding site. Proton NMR spectra of the actin peptide 114-118 in the presence and absence of ATP indicated that Arg-116 and Lys-118 are particularly involved in binding ATP. A strong binding of ATP to the peptide 106-124 also was measured. Tripolyphosphate bound to the peptide 106-124 somewhat more weakly than ATP. Binding involved residues 115-118 and 121-124, indicating the presence of a reverse turn between these segments. Proton resonances were assigned by using two-dimensional double quantum correlated spectroscopy, one-dimensional spin decoupling techniques, one-dimensional nuclear Overhauser enhancement ...

1987-03-10

498

Isobaric analog resonances in "8"9Y  

International Nuclear Information System (INIS)

Three resonances at the proton energies 7.0, 7.08, and 7.53 MeV on the target "8"8Sr were chosen to investigate the possibility of determining the amplitudes of the weak coupling experimentally. The corresponding "8"9Sr levels under investigation were 1.93 MeV ("5/_2"+), 2.00 MeV ("3/_2"+), and 2.46 MeV ("3/_2"+). Angular distributions were measured on resonance at 7.0, 7.08, and 7.53 MeV from proton inelastic scattering to the 1.84 MeV (2"+) state of "8"8Sr for differential cross section, analyzing power, spin-flip probability, and spin-flip asymmetry. A polarized beam of protons was used to obtain the analyzing power. The spin-flip probability was obtained from the coincidence of the prompt gamma rays from the (p,p'#gamma#) reaction with the scattered protons. With the polarized beam, the gamma coincidence technique was further used to obtain a spin-flip asymmetry measurement. From these measurements, the polarization was calculated, and the ...

499

Launching proton-dominated jets from accreting Kerr black holes: the case of M87  

Science.gov (United States)

A general relativistic model for the formation and acceleration of lowmass-loaded jets from systems containing accreting black holes is presented. The model is based on previous numerical results and theoretical studies in the Newtonian regime, but modified to include the effects of space-time curvature in the vicinity of the event horizon of a spinning black hole. It is argued that the boundary layer between the Keplerian accretion disk and the event horizon is best suited for the formation and acceleration of the accretion-powered jets in active galactic nuclei and micro-quasars. The model presented here is based on matching the solutions of three different regions: i- a weakly magnetized Keplerian accretion disk in the outer part, where the transport of angular momentum is mediated through the magentorotational instability, ii- a strongly magnetized, advection-dominated and ...

2011-07-01