WorldWideScience
1

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

2

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

3

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

4

Magnetic resonance imaging in human lymphodemas  

International Nuclear Information System (INIS)

The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).

1989-09-02

14

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

15

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

26

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

27

Current applications of magnetic resonance in coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)

1982-01-01

28

Numerical study of Cosmic Ray Diffusion in MHD turbulence  

CERN Document Server

We study diffusion of Cosmic Rays (CRs) in turbulent magnetic fields using test particle simulations. Electromagnetic fields are produced in direct numerical MHD simulations of turbulence and used as an input for particle tracing, particle feedback on turbulence being ignored. Statistical transport coefficients from the test particle runs are compared with earlier analytical predictions. We find qualitative correspondence between them in various aspects of CR diffusion. In the incompressible case, that we consider in this paper, the dominant scattering mechanism occurs to be the non-resonant mirror interactions with the slow-mode perturbations. Perpendicular transport roughly agrees with being produced by magnetic field wandering.

2010-01-01

29

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

30

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

31

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

32

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

33

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

34

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

39

Influence of resonant US on H-NMR at application of magnetic nanoparticles  

International Nuclear Information System (INIS)

2010 [1 p.] Germany Repp, Felix El-Miladi, Nouri Hoehl, Christian Jahanbakhsh,

2010-03-21

42

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with ...

1997-01-01

43

Electron paramagnetic resonance of nitroxide-doped magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.

2002-11-01

44

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

45

Studying the internal structure of granular magnetic nanocomposites by ferromagnetic resonance  

British Library Electronic Table of Contents (United Kingdom)

A method for estimating the form of magnetic nanoparticles in composite film structures based on the observation of ferromagnetic resonance phenomenon is offered. Within the model of the effective medium, an explanation is given for experimentally observed concentration and temperature dependences of resonant fields for composite nanosystem (Co45Fe45Z10) f +(Al2O3)100?f .

2010-01-01

46

High Voltage Measurements on Nine PFNs for the LHC Injection Kicker Systems  

CERN Document Server

Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies ...

2005-01-01

47

Effect of external pH on the cytoplasmic and vacuolar pHs in Mung bean root-tip cells. A T P nuclear magnetic resonance study  

Energy Technology Data Exchange (ETDEWEB)

The effect of the external pH on the intracellular pH in mung bean (Vigna mungo (L.) Hepper) root-tip cells was investigated with the T P nuclear magnetic resonance (NMR) method. The T P NMR spectra showed three peaks caused by cytoplasmic G-6-P, cytoplasmic Psub(i) and vacuolar Psub(i). The cytoplasmic and vacuolar pHs could be determined by comparing the Psub(i) chemical shifts with the titration curve. When the external pH was changed over a range from pH 3 to 10, the cytoplasmic pH showed smaller changes than the vacuolar pH, suggesting that the former is regulated more strictly than the latter. The H -ATPase inhibitor, DCCD, caused the breakdown of the mechanism that regulates the intracellular pH. H -ATPase appears to have an important part in the regulation of the intracellular pH.

1984-12-01

48

Steady particulate flows in a horizontal rotating cylinder  

Energy Technology Data Exchange (ETDEWEB)

Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRI) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio {approximately}7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity field in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit. {copyright} {ital 1998 American Institute of Physics.}

1998-06-01

49

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the ...

1985-08-01

50

Towards Resonant-State THz Laser Based on Strained p-Ge ...  

Science.gov (United States)

... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...

2006-07-01

51

Tarlov Cyst and Infertility  

UK PubMed Central (United Kingdom)

Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available

2009-04-01

54

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

55

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at ...

2009-03-01

56

Determination of left ventricular ejection fraction and wall thickness in magnetic resonance imaging at 1.0 Tesla in comparison to echocardiography and biplanar ventriculography  

International Nuclear Information System (INIS)

We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ventriculography ...

57

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends ...

1995-12-31

58

Magnetism of the Ni(110) and Ni(100) surfaces: local-spin-density-functional calculations using the thin-slab linearized augmented-plane-wave method  

International Nuclear Information System (INIS)

Results of self-consistent local-spin-density-functional calculations are reported for the first time for the Ni(110) surface, represented by one-, three-, and five-layer slabs. Calculations for one- and five-layer slabs of Ni(100) are also reported. The behavior of the surface magnetization with varying slab thickness elucidates the nature and origin of the surface magnetic moment. We predict a 13% enhancement of the Ni(110) surface magnetic moment compared to the bulk value. For the Ni(100) surface, we find a smaller surface enhancement about 7%, compared to bulk, which agrees with the results of Jepsen et al. The enhancement of surface magnetic moments on Ni(100) and Ni(110) surfaces is attributed to s-d dehybridization at the surface and to the presence of electrostatic shifts required to maintain layer-by-layer charge neutrality. We find that the total ...

59

Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?  

UK PubMed Central (United Kingdom)

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available

2009-03-01

60

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

61

Nuclear magnetic resonance and the question of 5f electron localization in the actinides  

International Nuclear Information System (INIS)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5f electrons. (author).

62

Nuclear magnetic resonance and the question of 5F electron localization in the actinides  

Science.gov (United States)

Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5Line integral electrons.

1976-01-01

63

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

64

Magnetic resonance appearance of fibromatosis  

International Nuclear Information System (INIS)

We reviewed retrospectively the magnetic resonance (MR) images of 14 soft-tissue lesions of fibromatosis (desmoid tumors) encountered in 11 patients. The lesions were typically inhomogeneous in texture and round to oval in configuration. Margins were well-defined in 78% of the lesions at presentation and were infiltrating in all recurrences. (orig./DG).

65

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

66

Fatty acid distribution in systems modeling the normal and diabetic human circulation. A 13C nuclear magnetic resonance study.  

UK PubMed Central (United Kingdom)

A nonperturbing 13C nuclear magnetic resonance (NMR) method was used to monitor the equilibrium distribution of carboxyl 13C-enriched fatty acids (FA) between distinct binding sites on human serum albumin,...Full Text Available

1991-04-01

67

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

68

Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness  

UK PubMed Central (United Kingdom)

BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available

69

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac ...

2009-03-01

70

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of ...

2006-06-01

71

Biochemical monitoring of black raspberry (Rubus coreanus Miquel) fruits according to maturation stage by ^1H NMR using multiple solvent systems  

British Library Electronic Table of Contents (United Kingdom)

Nuclear magnetic resonance (NMR) techniques coupled with multivariate data analysis were used to conduct monitoring of biochemical changes of black raspberry fruits at different stages of maturation and under various extraction and NMR dissolution solvent conditions: extraction with 50% methanol and D"2O as an NMR dissolution solvent, extraction with 50% methanol and 50% methanol-d"4 as an NMR dissolution solvent, and extraction with 100% ethyl acetate and 100% methanol-d"4 as an NMR dissolution solvent. Partial least-squares discriminant analysis reliably distinguished black raspberry fruits according to the maturation stage, whereby the relative levels of various compounds such as amino acids, organic acids, sugars and phenolic compounds were compared using analysis of variance. Sucrose ...

2011-01-01

72

Effect of magnet sorting using a simple resonance cancellation method on the RMS orbit distortion at the APS injector synchrotron  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.

1993-07-01

73

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a ...

74

CARM-klystron amplifier for accelerator applications  

International Nuclear Information System (INIS)

We consider the possibility of a cyclotron-autoresonance-maser (CARM) klystron configuration for accelerator applications as an alternative to the gyroklystron amplifier. The potential advantages, compared to gyroklystrons, include: 1) comparable efficiencies at lower values of the electron beam pitch ratio #alpha#, which should improve the beam quality and make the device substantially more stable against the excitation of parasitic mode, 2) operation far from cutoff, which should reduce the fields at cavity walls, allowing higher power operation, and 3) operation at lower magnetic fields for the same cyclotron harmonic number. However, there are two significant issues associated with the design of efficient, high-power CARMs. First, because of the higher value of k_Z, compared to gyroklystrons, CARMs are substantially more sensitive to parallel velocity spread (pitch-angle spread). Second, ...

2001-05-31

75

Magnetic resonance imaging assessment of brain maturation in preterm neonates with punctate white matter lesions  

International Nuclear Information System (INIS)

Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with 22 matched controls with a normal MR ...

2007-02-01

76

Magnetic Resonance Perfusion Imaging in Malformations of Cortical Development  

International Nuclear Information System (INIS)

Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side (rCBVRTSC and TTFMTSC) as well as those of the polymicrogyria/contralateral side ...

2007-10-01

77

Kondo effect in the systems of magnetic trimers on a metal surface  

International Nuclear Information System (INIS)

Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)

2010-11-01

78

Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis.  

DEFF Research Database (Denmark)

The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly to both the ...

2002-01-01

79

Consolidated silica glass from nanoparticles  

International Nuclear Information System (INIS)

A dense silica glass was prepared by consolidating a highly dispersed silicic acid powder (particle size 1H magic-angle spinning (MAS) NMR confirmed an increase in hydroxyl groups in the sample prepared by SPS relative to that of the conventional SiO2 reference glass. Aside from the comparably high water content, we conclude from the similarity of the IR-reflectance and the 29Si MAS NMR spectra of the SPS sample and the corresponding spectra of the conventionally prepared silica glass, that the short- and medium-range order is virtually the same in both materials. Raman spectroscopy, however, suggests that the number of three- and four-membered rings is significantly smaller in the SPS sample compared to the conventionally prepared sample. Based on these results we conclude that it is possible to prepare glasses by compacting amorphous powders by the SPS process. The SPS process may therefore enable the preparation of glasses with compositions ...

2008-09-01

80

Nuclear magnetic resonance on oriented XVTa and XXTa  

Energy Technology Data Exchange (ETDEWEB)

XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.

1984-08-01

81

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

82

The Influence of Moderate Hypercapnia on Neural Activity in the Anesthetized Nonhuman Primate  

UK PubMed Central (United Kingdom)

Hypercapnia is often used as vasodilatory challenge in clinical applications and basic research. In functional magnetic resonance imaging (fMRI), elevated CO2 is applied to derive stimulus-induced...Full Text Available

2008-11-01

83

Teaching electron diffraction and imaging of macromolecules.  

UK PubMed Central (United Kingdom)

Electron microscopic analysis can be used to determine the three-dimensional structures of macromolecules at resolutions ranging between 3 and 30 A. It differs from nuclear magnetic resonance spectroscopy...Full Text Available

1993-05-01

84

Synthesis and characterization of PVP-coated large core iron oxide nanoparticles as an MRI contrast agent  

UK PubMed Central (United Kingdom)

The purpose of this study was to synthesize biocompatible polyvinylpyrrolidone (PVP)-coated iron oxide (PVP-IO) nanoparticles and to evaluate their efficacy as a magnetic resonance imaging (MRI)...Full Text Available

2008-04-01

85

Specialization along the Left Superior Temporal Sulcus for Auditory Categorization  

UK PubMed Central (United Kingdom)

The affinity and temporal course of functional fields in middle and posterior superior temporal cortex for the categorization of complex sounds was examined using functional magnetic resonance imaging...Full Text Available

2010-12-01

86

Solid-state 13C NMR spectroscopy of a 13C carbonyl-labeled polypeptide  

UK PubMed Central (United Kingdom)

High resolution structural elucidation of macromolecular structure by solid-state nuclear magnetic resonance requires the preparation of uniformly aligned samples that are isotopically labeled. In...Full Text Available

1992-06-01

87

Retinal channelrhodopsin-2-mediated activity in vivo evaluated with manganese-enhanced magnetic resonance imaging  

UK PubMed Central (United Kingdom)

PurposeEctopic expression of light-sensitive proteins, such as channelrhodopsin-2, represent a novel approach for restoring light-detection capabilities to degenerated retina. A...Full Text Available

88

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

89

Nylon biodegradation by lignin-degrading fungi.  

UK PubMed Central (United Kingdom)

The biodegradation of nylon by lignin-degrading fungi was investigated. The fungus IZU-154 significantly degraded nylon-66 membrane under ligninolytic conditions. Nuclear magnetic resonance analysis...Full Text Available

1997-01-01

90

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

91

New approach to study fast and slow motions in lipid bilayers: application to dimyristoylphosphatidylcholine-cholesterol interactions.  

UK PubMed Central (United Kingdom)

Natural abundance 13C solid-state nuclear magnetic resonance spectroscopy was used to investigate the effect of the incorporation of cholesterol on the dynamics of dimyristoylphosphatidylcholine (DMPC)...Full Text Available

1995-05-01

92

Neurosarcoidosis--demonstration of meningeal disease by gadolinium enhanced magnetic resonance imaging.  

UK PubMed Central (United Kingdom)

Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available

1991-06-01

93

Monitoring of Tumor Promotion and Progression in a Mouse Model of Inflammation-Induced Colon Cancer with Magnetic Resonance Colonography1  

UK PubMed Central (United Kingdom)

Early detection of precancerous tissue has significantly improved survival of most cancers including colorectal cancer (CRC). Animal models designed to study the early stages of cancer are valuable...Full Text Available

2009-03-01

94

Measuring the thickness of the human cerebral cortex from magnetic resonance images  

UK PubMed Central (United Kingdom)

Accurate and automated methods for measuring the thickness of human cerebral cortex could provide powerful tools for diagnosing and studying a variety of neurodegenerative and psychiatric disorders....Full Text Available

2000-09-26

95

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

96

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models  

UK PubMed Central (United Kingdom)

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation....Full Text Available

2009-05-01

97

MRI Findings of Pericardial Fat Necrosis: Case Report  

UK PubMed Central (United Kingdom)

Pericardial fat necrosis is an infrequent cause of acute chest pain and this can mimic acute myocardial infarction and acute pericarditis. We describe here a patient with the magnetic resonance imaging...Full Text Available

2011-05-01

100

Interictal Functional Connectivity of Human Epileptic Networks Assessed by Intracerebral EEG and BOLD Signal Fluctuations  

UK PubMed Central (United Kingdom)

In this study, we aimed to demonstrate whether spontaneous fluctuations in the blood oxygen level dependent (BOLD) signal derived from resting state functional magnetic resonance imaging (fMRI) reflect...Full Text Available

101

In vivo study of chloroplast volume regulation.  

UK PubMed Central (United Kingdom)

This paper describes a new technique that can be used to study chloroplast volume regulation in vivo. Nuclear magnetic resonance spectroscopy was used to measure relative amounts of chloroplast water...Full Text Available

1992-05-01

102

Energy metabolism of the untrained muscle of elite runners as observed by 31P magnetic resonance spectroscopy: evidence suggesting a genetic endowment for endurance exercise.  

UK PubMed Central (United Kingdom)

The purpose of this study was to investigate whether genetically determined properties of muscle metabolism contribute to the exceptional physical endurance of world-class distance runners. ATP, phosphocreatine,...Full Text Available

1988-12-01

103

Effects of norepinephrine infusion on myocardial high-energy phosphate content and turnover in the living rat.  

UK PubMed Central (United Kingdom)

Using 31P-nuclear magnetic resonance, we studied the relationship between myocardial high-energy phosphate content and flux values for the creatine kinase reaction in the living rat under inotropic...Full Text Available

1987-06-01

104

EXPONENTIAL TENSORS: A FRAMEWORK FOR EFFICIENT HIGHER-ORDER DT-MRI COMPUTATIONS  

UK PubMed Central (United Kingdom)

In Diffusion Tensor Magnetic Resonance Image (DT-MRI) processing a 2nd order tensor has been commonly used to approximate the diffusivity function at each lattice...Full Text Available

2007-05-15

105

Current Role and Future Perspectives of Magnetic Resonance Spectroscopy in Radiation Oncology for Prostate Cancer  

UK PubMed Central (United Kingdom)

Prostatic neoplasms are not uniformly distributed within the prostate volume. With recent developments in three-dimensional intensity-modulated and imageguided radiation therapy, it is possible to treat...Full Text Available

2007-06-01

106

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

107

Cardiovascular magnetic resonance guided electrophysiology studies  

UK PubMed Central (United Kingdom)

Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available

108

Calorimetric and spectroscopic studies of the polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines.  

UK PubMed Central (United Kingdom)

The polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines was investigated by differential scanning calorimetry, 31P-nuclear magnetic resonance, and Fourier...Full Text Available

1993-04-01

109

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

110

Polarized proton acceleration at the Brookhaven AGS  

Energy Technology Data Exchange (ETDEWEB)

At the conclusion of polarized proton commissioning in February 1986, protons with an average polarization of 45%, momentum of 21.7 GeV/c, and intensity of 2 x 10/sup 10/ protons per pulse, were extracted to an external polarimeter at the Brookhaven AGS. In order to maintain this polarization, five intrinsic and nearly forty imperfection depolarizing resonances had to be corrected. An apparent interaction between imperfection and intrinsic resonances occurring at very nearly the same energy was observed and the correction of imperfection resonances using ''beat'' magnetic harmonics discovered in the previous AGS commissioning run was further confirmed.

1986-01-01

111

Models of cardiac electromechanics based on individual hearts imaging data  

British Library Electronic Table of Contents (United Kingdom)

Current multi-scale computational models of ventricular electromechanics describe the full process of cardiac contraction on both the micro- and macro- scales including: the depolarization of cardiac cells, the release of calcium from intracellular stores, tension generation by cardiac myofilaments, and mechanical contraction of the whole heart. Such models are used to reveal basic mechanisms of cardiac contraction as well as the mechanisms of cardiac dysfunction in disease conditions. In this paper, we present a methodology to construct finite element electromechanical models of ventricular contraction with anatomically accurate ventricular geometry based on magnetic resonance and diffusion tensor magnetic resonance imaging of the heart. The electromechanical model couples detailed repres...

2011-01-01

112

Inborn Errors of Metabolism Presenting in Childhood  

British Library Electronic Table of Contents (United Kingdom)

Abstract Neurodegenerative and neurometabolic disorders may cause significant morbidity and mortality in children. Imaging is important in early diagnosis of metabolic disorders and in determining the extent of brain injury. Especially after the development of new techniques such as diffusion-weighted magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), neuroimaging plays more important role in the diagnosis and management of these disorders. In these disorders, usually a mutation causes a clinically significant block in one or more metabolic pathways. This blockage usually results in either a deficiency of the product or in an accumulation of substrate with damage induced by either storage or toxicity. The presenting symptoms are usually nonspecific. In some of the ...

2011-01-01

113

In vivo magnetic resonance techniques and drug discovery  

International Nuclear Information System (INIS)

The long and resource intensive process of drug discovery and development is confronted with the basic challenge of providing effective and safe therapies at reasonably low costs. The better the mechanism of a disease is known, the higher the probability to find an appropriate therapy. Also, the better and earlier a disease can be diagnosed and characterized, the higher the chance to be able to interfere in this process with a chemical entity. This reasoning sets the framework for the use of imaging in drug discovery. We discuss the relevance of magnetic resonance imaging and spectroscopy to derive anatomical, functional, metabolic and target-related information in the context of pharmacological research in vivo. (author)

2006-03-01

114

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

115

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

116

Magnetic resonance studies of photosynthetic reaction centers and porphyrins  

Science.gov (United States)

During the period covered by this report research has been concerned with the study of photo-induced electron transfer reactions from porphyrins to acceptor molecules with time-resolved Electron Paramagnetic Resonance (EPR) methods. Excited-state electron transfer reactions are of importance from a fundamental point of view and in connection with applications in homogeneous and heterogeneous photosensitization, photopolymerization, and solar energy conversions. For this reason, the study of photo-induced electron transfer reactions is of considerable interest.

1989-11-01

117

Measurement of the K-shell ionization probability across a wide resonance: /sup 88/Sr(p,p/sub 0/) at 6. 06 MeV  

Energy Technology Data Exchange (ETDEWEB)

We have measured the K-shell ionization probability across the 6.06-MeV resonance in /sup 88/Sr(p,p/sub 0/) where the resonance width is large compared to the energy transferred to the electron. The results are found to agree quantitatively with the theory developed by Blair and Anholt. The effect of the time delay on the ionization probability, introduced by the nuclear scattering at the resonance energy, is discussed.

1982-09-01

118

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.  

DEFF Research Database (Denmark)

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global ...

2004-01-01

119

Sol-gel coatings with phosphonate functionalities for surface modification of magnesium alloys  

International Nuclear Information System (INIS)

Hybrid organic-inorganic coatings with phosphonate functionalities have been synthesized and evaluated as prospective surface treatments for magnesium materials. These coatings have been processed via a sol-gel route by hydrolysis and condensation of a mixture of diethylphosphonatoethyltriethoxy-silane and tetraethoxy-silane with variable molar ratios. The coatings morphology and the surface chemistry at the coating/substrate interface have been characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, "3"1P nuclear magnetic resonance spectroscopy, and time-of-flight secondary ion mass spectrometry. The corrosion protection performance of the coatings deposited on magnesium alloy AZ31B has been examined by a group of electrochemical techniques including potentiodynamic polarization and electrochemical impedance spectroscopy. In addition, a scanning Kelvin probe technique has been used to investigate interfacial ...

2006-08-30

120

Non-white noise in fMRI: does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2005-01-01

121

Non-white noise in fMRI: Does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2006-01-01

122

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI ...

2000-05-01

123

Effect of external pH on the cytoplasmic and vacuolar pHs in Mung bean root-tip cells  

International Nuclear Information System (INIS)

The effect of the external pH on the intracellular pH in mung bean (Vigna mungo (L.) Hepper) root-tip cells was investigated with the "3"1P nuclear magnetic resonance (NMR) method. The "3"1P NMR spectra showed three peaks caused by cytoplasmic G-6-P, cytoplasmic Psub(i) and vacuolar Psub(i). The cytoplasmic and vacuolar pHs could be determined by comparing the Psub(i) chemical shifts with the titration curve. When the external pH was changed over a range from pH 3 to 10, the cytoplasmic pH showed smaller changes than the vacuolar pH, suggesting that the former is regulated more strictly than the latter. The H"+-ATPase inhibitor, DCCD, caused the breakdown of the mechanism that regulates the intracellular pH. H"+-ATPase appears to have an important part in the regulation of the intracellular pH. (author).

124

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of ...

1988-01-01

125

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two ...

1995-10-01

126

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

127

Nuclear magnetic resonance study of La_3X compounds and related phases  

International Nuclear Information System (INIS)

Normal state nuclear magnetic resonance studies of the La_3In, La_3Tl compounds have been made in order to investigate the origin of the large temperature-dependent magnetic susceptibility. It is possible to analyse the different contributions to the susceptibility using Knight-shift and relaxation time T_1 measurements of In"1"1"5 and Tl"2"0"5 nuclei. The exchange enhancement of the spin-susceptibility chisub(pd) is of the same order as that found in A-15 compounds and the strong temperature-dependence of chi(T) is attributed to the presence of a peak in the electronic density of states near the Fermi level. The variation of the Knight-shift in the ternary alloys La_3Xsub(1-y)Xsub(y)sup(') is analogous to that observed in the corresponding La_3X phases, on the other hand the Knight-shift in the carbides La_3XC is temperature independent. (author).

128

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were presented as color-coded anatomically-mapped ...

129

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted images. As for lesions <2 cm, Gd-DTPA ...

1991-01-01

130

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower ...

1993-06-01

131

Crossover of the magnetic levels and adiabatic magnetization of the mesoscopic cluster V15  

British Library Electronic Table of Contents (United Kingdom)

The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...

2006-01-01

132

Resonant frequencies and Q factors of dielectric parallelepipeds by measurement and by FDTD  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the measurement and computation of the resonant frequencies and the associated Q factors of dielectric parallelepipeds made of high-permittivity, low-loss ceramic materials. Each resonance peak is measured separately with a fine frequency step. A curve-fitting method is used to accurately estimate the resonant frequency and 3 dB bandwidth from the somewhat noisy measured data. The finite-difference time-domain method is used to compute the initial portion of the backscattered field due to a Gaussian pulse plane wave. The time response is then extended to zero value by Prony`s method. The measured and computed data is compared for a parallelepiped resonator of permittivity 37.84.

1994-12-31

133

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous ...

2003-07-01

134

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...

1999-04-01

135

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

136

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in ...

2009-05-15

137

The 2s{sup 1}2p{sup 4} autodetachment resonance in the C{sup -} negative ion  

Energy Technology Data Exchange (ETDEWEB)

The calculations of the photodetachment cross section for the C{sup -} negative ion has been performed within the newly-developed many-body theory method, the RPAE interchannel interaction and dynamic relaxation and polarization corrections being included. The 2s{sup 1}2p{sup 4} shape resonance is shifted to a higher photon energy and broadens as compared to the resonance parameters determined earlier within the RPAE, which is consistent with the experimental evidence and the recent R-matrix calculations. (orig.) 18 refs.

1998-08-10

138

Engineering electromagnetic response of composite terahertz metamaterial with broken symmetry  

Science.gov (United States)

We proposed and numerically investigated the influence of spatial symmetry on the terahertz frequency region response of composite planar metamaterials based on deformed split ring resonators. Compared with the original simple structures, the composite metamaterials with different spatial symmetries exhibited exotic electromagnetic properties. The electromagnetic response of a specific configuration with C4 symmetry was identical to the structure with simple lattice. Especially, for configurations with broken symmetry, very sharp Drude-like resonances with high quality factor were observed. The electric field and current distribution associated the resonances were analyzed for deep understanding of the underlying physical properties.

2011-09-01

139

Ultrasensitive laser isotope analysis in an ion-storage ring  

Energy Technology Data Exchange (ETDEWEB)

We propose a novel method for ultrasensitive isotope analysis that combines magnetic mass selection, resonant charge-exchange neutralization, and resonant laser ionizaion. Our method attains high isotopic abundance selectivity by means of continuous multistage separation of ions stored in a small ring. For the environmentally interesting case of /sup 90/Sr versus /sup 88/Sr we estimate that sensitivity better than 10/sup -15/ for a throughput of 10/sup 13/ atoms/sec and an efficiency (after the ion source) greater than 10% are readily achievable.

1985-09-01

140

Trapping of neutral atoms with resonant microwave radiation  

Energy Technology Data Exchange (ETDEWEB)

We duscuss a resonant microwave trap for neutral atoms. Because of the long spontaneous radiation time this trap is remarkably different from the optical trap. It also has advantages over static magnetic traps that trap the excited spin state of the lowest electronic level, in that atoms predominantly in the spin ground state can be trapped. We analyze the relaxation-ejection lifetime of atoms in such a trap using the formalism of dressed atomic states. Results are appliedi to atomic hydrogen and the possibility of Bose-Einstein condensation is considered.

1989-05-15

141

Quasi-ternary nanoparticle superlattices through nanoparticle design  

Energy Technology Data Exchange (ETDEWEB)

Individual nanoscale building blocks exhibit a wide range of size-dependent properties, since their size can be tuned over known characteristic length scales of bulk materials. In the last several years, the possibility of combining different materials in the form of two and three component nanoparticles (NPs) has been extensively explored. Also multi-component materials can be obtained via self-assembly of NPs from their binary colloidal mixtures. These new nanocrystal solids may possess tunable collective properties that originate from interactions between size and composition controlled building blocks. Exchange coupling between neighboring NPs of magnetically soft and hard materials enhances the magnetic energy product of the nanocomposite material. Randomly mixed solids of small and large semiconducting CdSe NPs revealed enhancement of photoluminescence intensity of large semiconductor particles accompanied by quenching of ...

2007-06-19

142

Magnetic resonance imaging of stents. Quantitative in vitro examination at 3 Tesla; Magnetresonanztomographie von Stents. Quantitative MR-Untersuchungen in vitro bei 3 Tesla  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we calculated the apparent vascular lumen within ...

2009-07-01

143

Nuclear resonant spectroscopy at Bragg reflections from periodic multilayers: Basic effects and applications  

Science.gov (United States)

A systematic study of the Bragg nuclear resonant reflectivity from periodic multilayers in the energy and time domains is presented. Using the kinematical approach of the general reflectivity theory we describe the basic features of the time evolution of the reflected wave after a pulsed excitation of resonant multilayers by synchrotron radiation. Effects of the collective excitation have been examined such as the shift of quantum beat phases, the interplay between electronic and nuclear subsystem excitations depending on their relative position in a multilayer, the energy and time evolution of standing waves inside a resonant multilayer, and their influence on the reflectivity spectra. The exact expression for the reflectivity by a thin resonant layer placed inside a multilayer structure has been derived. The observed shift of the delayed reflectivity Bragg peak relative to the prompt peak is explained ...

2005-09-15

144

Multiple resonances and Coulomb blockade splitting in a quantum dot-DNA composite  

British Library Electronic Table of Contents (United Kingdom)

Inspired by the recent realizations of quantum dot (QD)-DNA conjugation, we study the spectral density of a magnetic impurity coupled to a mesoscopic semiconducting host. Using a combination of exact diagonalization technique and an analytic approach, we demonstrate that various types of resonances occur according to the relative position of impurity levels (IL) with respect to the host levels (HL). While the usual Coulomb peaks appear when the IL lie inside a band gap, with IL approaching HL and hybridization activated, they shift nonlinearly with the repulsion strength and even undergo splitting for a strong hybridization. When IL merge into HL, multiple resonances of a comblike structure are found along with a parity effect.

2011-01-01

145

Primary cutaneous Ewing's sarcoma/primitive neuroectodermal tumor manifesting numerous small and huge ulcerated masses: its complete remission by chemotherapy and magnetic resonance imaging findings  

International Nuclear Information System (INIS)

Extraskeletal Ewing's sarcoma (ES) and primitive neuroectodermal tumor (PNET) are widely regarded as clinically and histologically identical tumors which consist of small blue round cells. Extraskeletal ESs/PNETs usually occur in the deep soft tissues of the paraspinal region, chest wall, or lower extremities. However, superficially located cases, so-called cutaneous ESs/PNETs, are exceedingly rare, and the vast majority of the reported cases present as a single small mass. We present magnetic resonance imaging (MRI) findings and clinical course of a unique case of primary cutaneous ES/PNET presenting as numerous huge masses with severe ulceration on them. (orig.)

2010-06-01

146

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

147

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection of joint diseases ...

148

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

149

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line ...

2002-08-01

150

Electron cyclotron current drive at {omega} approx. = {omega}{sub c} with X-mode launched from the low field side  

Energy Technology Data Exchange (ETDEWEB)

The electron cyclotron resonance layer in a tokamak, {omega}={omega}{sub c}(r), is not accessible by the extraordinary wave from the low field side, because it is shielded by a cutoff layer. However, a X-mode launched with a nonzero toroidal angle propagates at the cutoff parallel to the magnetic field and has a circular polarization. Therefore it can already at the cutoff layer interact efficiency with electrons via the Doppler shifted resonance. The driven current can be substantially higher than that driven by the second harmonic X-mode. The applicability of this current drive scheme is limited to rather low values of {omega}{sub p}{sup 2}/{omega}{sub c}{sup 2}, but may be of interest for high magnetic field devices. (author)

2000-02-01

151

Assessment of GABARAP self-association by its diffusion properties  

Energy Technology Data Exchange (ETDEWEB)

Gamma-aminobutyric acid type A receptor-associated protein (GABARAP) belongs to a family of small ubiquitin-like adaptor proteins implicated in intracellular vesicle trafficking and autophagy. We have used diffusion-ordered nuclear magnetic resonance spectroscopy to study the temperature and concentration dependence of the diffusion properties of GABARAP. Our data suggest the presence of distinct conformational states and provide support for self-association of GABARAP molecules. Assuming a monomer-dimer equilibrium, a temperature-dependent dissociation constant could be derived. Based on a temperature series of {sup 1}H{sup 15}N heteronuclear single quantum coherence nuclear magnetic resonance spectra, we propose residues potentially involved in GABARAP self-interaction. The possible biological significance of these observations is discussed with respect to alternative scenarios of oligomerization.

2010-09-15

152

Magnetic response of ultrathin Fe on MgO: A polarized neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.

1994-11-15

153

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research ...

154

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high ...

2008-06-01

155

Duality in Neutrino Reactions  

Energy Technology Data Exchange (ETDEWEB)

On the basis of the phenomenological model for baryon resonance production in lepton nucleon and lepton nucleus scattering we investigate to what extent quark hadron duality is applicable to the neutrino structure functions and how it compares with duality in electron scattering.

2007-12-01

156

Review of the microscopic cross sections for the americium isotopes in the resolved resonance region. [0. 5 eV to 10 keV  

Science.gov (United States)

The differential cross section measurements for /sup 241/Am, /sup 242m/Am and /sup 243/Am are reviewed in the energy range from 0.5 eV to 10 keV. Parameters extracted from resonance analysis, such as the neutron strength function, the average level spacing, the average capture and fission widths, are compared for the various measurements. The average capture and fission cross sections from 100 eV to 10 keV are directly compared. The status of the data set is discussed with suggestions for further measurements. 24 references.

1978-11-16

157

Roles of the #beta# 146 histidyl residue in the molecular basis of the Bohr Effect of hemoglobin: A proton nuclear magnetic resonance study  

International Nuclear Information System (INIS)

Assessment of the roles of the carboxyl-terminal #beta#146 histidyl residues in the alkaline Bohr effect in human and normal adult hemoglobin by high-resolution proton nuclear magnetic resonance spectroscopy requires assignment of the resonances corresponding to these residues. By a careful spectroscopic study of human normal adult hemoglobin, enzymatically prepared des(His146#beta#)-hemoglobin, and the mutant hemoglobins Cowtown (#beta#146His #-># Leu) and York (#beta#146His #-># Pro), the authors have resolved some of these conflicting results. By a close incremental variation of pH over a wide range in chloride-free 0.1 M N-(2-hydroxyethyl)piperazine-N'-2-ethanesulfonic acid buffer, a single resonance has been found to be consistently missing in the proton nuclear magnetic resonance spectra of these hemoglobin variants. The results indicate that the ...

158

On the temperature dependence of the magnetic excitations  

International Nuclear Information System (INIS)

We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# ...

2005-07-15

159

The brain-derived neurotrophic factor Val66Met polymorphism is associated with reduced functional magnetic resonance imaging activity in the hippocampus and increased use of caudate nucleus-dependent strategies in a human virtual navigation task  

UK PubMed Central (United Kingdom)

Multiple memory systems are involved in parallel processing of spatial information during navigation. A series of studies have distinguished between hippocampus-dependent ‘spatial’ navigation,...Full Text Available

2011-03-01

160

Structure of a mycobacterial polysaccharide-fatty acyl-CoA complex: nuclear magnetic resonance studies.  

UK PubMed Central (United Kingdom)

MMP, a linear alpha 1 leads to 4 linked polymer of 3-O-methylmannose, regulates the fatty acid synthetase from Mycobacterium smegmatis by forming stoichiometric complexes with the long-chain acyl-CoA...Full Text Available

1980-05-01

161

Right-sided invasive metastatic thymoma of the heart  

British Library Electronic Table of Contents (United Kingdom)

Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.

2011-01-01

162

Quality control in Nuclear Magnetic Resonance Imaging. Indications et strategies pour le controle de qualite en IRM  

Energy Technology Data Exchange (ETDEWEB)

In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.

1993-01-01

163

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

164

Metastatic Ewing's sarcoma to the skull: CNS involvement excluded by MRI  

International Nuclear Information System (INIS)

A case of metastatic Ewing's sarcoma to the skull is presented, demonstrating the superiority of magnetic resonance imaging over other imaging modalities to exclude CNS involvement. Precise delineation of different tumor components in extradural location contained in an intact dural rim together with compressed cortex showing no signs of tumorous involvement constituted an MRI appearance allowing us to exclude tumor outgrowth into the brain. (orig.).

165

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

166

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

167

MRI and 1H MRS of The Breast: Presence of a Choline Peak as Malignancy Marker is Related to k21 Value of the Tumor in Patients with Invasive Ductal Carcinoma  

UK PubMed Central (United Kingdom)

To assess which specific morphologic features, enhancement patterns, or pharmacokinetic parameters on breast Magnetic Resonance Imaging (MRI) could predict a false-negative outcome of Proton...Full Text Available

2008-01-01

168

MR findings of primary Ewing's sarcoma of greater wing of sphenoid  

International Nuclear Information System (INIS)

Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd

2002-12-01

169

Hyperfine interactions in HCOOD and DCOOH molecules  

Energy Technology Data Exchange (ETDEWEB)

The method of double microwave--radio-frequency resonance has been used to obtain spectra of the 2/sub 11/reverse arrow2/sub 12/ and 3/sub 21/reverse arrow3/sub 22/ transitions in HCOOD, DCOOH, and HCOOH molecules. The constants of the quadrupole bond of the deuterons have been determined, magnetic interactions being taken into acocunt. A comparison with results of previous studies is given.

1986-05-01

170

Electron phonon properties of A-15 compounds and Chevrel phases  

International Nuclear Information System (INIS)

A review of the information on the electron and phonon spectra in the A-15 compounds and Chevrel phase superconductors obtained from nuclear magnetic resonance, heat capacity, and Moessbauer effect experiments is presented. Relationships of the Fermi energy electrons and the soft phonons to the strength of the electron-phonon interaction are discussed.

171

Electron and phonon properties of A-15 compounds and Chevrel phases  

International Nuclear Information System (INIS)

A review of the information on the electron and phonon spectra in the A-15 compounds and Chevrel phase superconductors obtained from nuclear magnetic resonance, heat capacity, and Moessbauer effect experiments is presented. Relationships of the Fermi energy electrons and the soft phonons to the strength of the electron-phonon interaction are discussed.

172

Effect of Elicitation and Changes in Extracellular pH on the Cytoplasmic and Vacuolar pH of Suspension-Cultured Soybean Cells 1  

UK PubMed Central (United Kingdom)

We have employed both 31P nuclear magnetic resonance spectroscopy and two intracellular fluorescent pH indicator dyes to monitor the pH of the vacuole and cytoplasm of suspension-cultured...Full Text Available

1992-02-01

173

Characterization of polymers for microcellular foams  

Energy Technology Data Exchange (ETDEWEB)

We have measured, by {sup 1}H and {sup 13}C nuclear magnetic resonance (NMR), the percent deuteration, the tacticity and the purity of several polymers and one solvent used in the preparation of microcellular foams. The percent deuteration was measured for polystyrene, polyacrylonitrile and polyethylene. The tacticities of polystyrene and polyacrylonitrile were determined. The purity and degradation products of polyacrylonitrile and maleic anhydride were examined. This report documents the experimental procedures and results of these measurements.

1992-03-01

174

31P NMR Observations on the Effect of the External pH on the Intracellular pH Values in Plant Cell Suspension Cultures 1  

UK PubMed Central (United Kingdom)

31P nuclear magnetic resonance (NMR) spectroscopy was used to monitor the response of oil palm (Elaeis guineensis) and carrot (Daucus carota) cell suspensions...Full Text Available

1990-06-01

175

Spatial Damping of Propagating Kink Waves Due to Resonant Absorption: Effect of Background Flow  

CERN Document Server

Observations show the ubiquitous presence of propagating magnetohydrodynamic (MHD) kink waves in the solar atmosphere. Waves and flows are often observed simultaneously. Due to plasma inhomogeneity in the perpendicular direction to the magnetic field, kink waves are spatially damped by resonant absorption. The presence of flow may affect the wave spatial damping. Here, we investigate the effect of longitudinal background flow on the propagation and spatial damping of resonant kink waves in transversely nonuniform magnetic flux tubes. We combine approximate analytical theory with numerical investigation. The analytical theory uses the thin tube (TT) and thin boundary (TB) approximations to obtain expressions for the wavelength and the damping length. Numerically, we verify the previously obtained analytical expressions by means of the full solution of the resistive MHD eigenvalue problem beyond the TT ...

2011-01-01

176

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists ...

1991-09-15

177

Stability of superconducting ISABELLE dipole magnets  

Energy Technology Data Exchange (ETDEWEB)

The concept of the minimum propagating zone (MPZ) is used to examine the causes of quenches in ISABELLE cosine theta superconducting dipole magnets. The size of disturbances large enough to exceed the MPZ and initiate quenches is estimated and compared with the size of disturbances which may be produced in the magnets. A suggestion for reducing the size of these disturbances through individual support of the coil block is outlined.

1981-04-01

178

Mean magnetic moments of polycrystalline Ce compounds in a tetragonal crystal field  

International Nuclear Information System (INIS)

An alternative and graphical representation of the magnetic moment and the effective paramagnetic moment for polycrystalline Ce compounds with tetragonal site symmetry is described. The reduced moments can be calculated by means of standard perturbation theory. The calculated values deduced from the ground states of CeCu_2Si_2, CeRu_2Si_2, and CePd_2Si_2 polycrystals are compared with experimental magnetic moments.

179

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the ...

1998-05-01

180

Nuclear magnetic resonance on oriented "1"7"5Ta and "1"7"7Ta  

International Nuclear Information System (INIS)

"1"7"5Ta and "1"7"7Ta nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies #nu#="+#mu#B sub(HF)/Ih"+ of the "1"7"5Ta and "1"7"7Ta ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of "1"8"1Ta in Fe, the magneticmoments have been deduced: "+#mu#("1"7"5Ta, 7/2"+)"+=2.270(45) and "+#mu#("1"7"7Ta, 7/2"+)"+=2.250(45)#mu# sub(N). These values of the magnetic moments are discussed in the framework of the rotational model. (author).

181

Nodular fasciitis: correlation of MRI findings and histopathology  

Energy Technology Data Exchange (ETDEWEB)

Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had ...

2002-03-01

182

Optical Feshbach Resonances in Alkaline Earth Atoms  

Science.gov (United States)

Recent proposals have shown that a quantum degenerate gas of alkaline earth atoms can be used for a number of novel quantum computing and quantum simulation experiments. Strontium is a good candidate for such experiments because it can be controlled with high precision, as demonstrated in recent atomic clock experiments. Unfortunately, the small scattering length of strontium is not amenable to evaporative cooling techniques that are used to reach quantum degeneracy. Furthermore, increasing the scattering length of alkaline earths with a magnetic Feshbach resonance is not possible due to their spinless electronic ground state configuration. However, recent theoretical and experimental work suggests the possibility of changing scattering lengths in alkaline earths with laser light. Using this optical Feshbach resonance near strontium's narrow ^1S0->^3P1 intercombination transition might allow its scattering length to be ...

2009-10-01

183

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

184

The magnetic resonance and its agro-industry applications; a review  

International Nuclear Information System (INIS)

The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage and conservation of ...

185

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

186

How the Performance of a Superconducting Magnet is affected by theConnection between a small cooler and the Magnet  

Energy Technology Data Exchange (ETDEWEB)

As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the ...

2005-09-08

187

Strength functions of primary transitions following thermal neutron capture in strontium  

Energy Technology Data Exchange (ETDEWEB)

The primary E1, M1 and E2 ..gamma..-radiation in /sup 87,88,89/Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, ..gamma..) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for /sup 90/Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models.

1989-04-01

188

Strength functions of primary transitions following thermal neutron capture in strontium  

International Nuclear Information System (INIS)

The primary E1, M1 and E2 #gamma#-radiation in "8"7","8"8","8"9Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, #gamma#) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for "9"0Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models. ...

189

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...

1996-05-01

190

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well defined in four out of the ...

2005-09-01

191

Patterns of ovarian morphology in polycystic ovary syndrome: a study utilising magnetic resonance imaging  

Energy Technology Data Exchange (ETDEWEB)

To evaluate and compare MRI-based ovarian morphology in groups of women with polycystic ovary syndrome (PCOS) and controls. All PCOS cases (n = 44) had oligo-amenorrhoea and hyperandrogenism irrespective of ovarian morphology, and fulfilled NIH/Rotterdam diagnostic criteria for PCOS. All control women (n = 40) had normal menses and normoandrogenaemia. All subjects were of white British/Irish origin and pre-menopausal. Group comparisons were based on independent-sample t tests. Polycystic ovarian morphology was defined by at least 12 follicles 2-9 mm in diameter and/or an ovarian volume greater than 10 cm{sup 3}. Ovarian morphology differed significantly in PCOS cases and controls (follicle number geometric mean [SD range] 18.6 [9.9, 35.0] vs 6.6 [3.1, 14.2], unadjusted P = 1.3 x 10{sup -16}; calculated ovarian volume 8.8 cm{sup 3} [5.0, 15.5] vs 5.1 cm{sup 3} [2.5, 10.3], unadjusted P = 3.0 x 10{sup -7}; peripheral follicle location in 55% vs 18% of ovaries, P = ...

2010-05-15

192

Monitoring the effect of chemotherapy in Ewing's sarcoma of bone with MR imaging  

International Nuclear Information System (INIS)

Magnetic resonance (MR) imaging was performed in 26 patients with Ewing's sarcoma of bone preceding and following neoadjuvant chemotherapy, to assess tumour response non-invasively prior to surgery. T1- and T2-weighted spin echo images were obtained. Changes including intra- and extramedullary signal intensities, tumour demarcation, tumour volume and the appearance of residual extramedullary tumour were compared with histophathology of the resected specimens. Reduction of tumour volume was significantly higher in good responders. Other single parameters did not correlated with histologic tumour response. However, when several MR parameters summarized in a classification system were combined, a positive correlation with histopathologic response was found. A limited decrease of tumour volume (<25 %) and/or residual soft tissue mass following chemotherapy correlated with a poor response. An inhomogeneous, well-defined cuff ...

193

Magnetic resonance imaging of cerebral anomalies in subjects with resistance to thyroid hormone  

Energy Technology Data Exchange (ETDEWEB)

Resistance to thyroid hormone (RTH) is an autosomal dominant disease caused by mutations in the human thyroid receptor beta gene on chromosome 3. Individuals with RTH have an increased incidence of attention deficit hyperactivity disorder (ADHD). The purpose of this study was to search for developmental brain malformations associated with RTH. Forty-three subjects (20 affected males [AM], 23 affected females [AF]) with resistance to thyroid hormone and 32 unaffected first degree relatives (18 unaffected males [UM], 14 unaffected females [UF]) underwent MRI brain scans with a volumetric acquisition that provided 90 contiguous 2 mm thick sagittal images. Films of six contiguous images beginning at a standard sagittal position lateral to the insula were analyzed by an investigator who was blind with respect to subject characteristics. The presence of extra or missing gyri in the parietal bank of the Sylvian fissure (multimodal association cortex) and multiple Heschl`s transverse gyri ...

1995-06-19

194

MR imaging study on external hydrocephalus in infants: extracerebral space developmental and pathological enlargement  

International Nuclear Information System (INIS)

Objective: To analyze the characteristics of external hydrocephalus in infancy with MR imaging, and to explore the cause of accumulation of extracerebral fluid and the relation with brain development. Methods: Conventional magnetic resonance T_1 weighted imaging (T_1WI) and T_2 weighted imaging (T_2WI) were performed in 46 infants aged 2 years or younger with external hydrocephalus (EH), and the results were analyzed. They were divided into 7 age groups. The width of extractable space was measured on T_2WI and compared with normal standard. Results: EH mainly resulted from infection, subdural hematoma or subarachnoid hemorrhage, HIE, which were 67.4% (31/46 cases) of the cases; EH with unknown cause were 26.1% (12/46 cases). EH was mainly located at the foreside of cerebral convexity, of which 80.4% (37/46 cases )was predominantly in the subarachnoid space, 8.7% (4/46 cases) in subdural space, 10.9% was subdural coexisted ...

2006-05-01

195

Long-Term Follow-Up of Percutaneous Balloon Angioplasty in Adult Aortic Coarctation  

International Nuclear Information System (INIS)

Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly ...

2000-09-01

196

Injuries of the tibio-talar joint and preoperative planning. Verletzungen des oberen Sprunggelenks aus unfallchirurgischer Sicht  

Energy Technology Data Exchange (ETDEWEB)

The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with ...

1991-12-01

197

Evaluation of indexes for tumor growth and effect of radiation therapy using MRS; Experimental studies on SCCVII tumor bearing mice  

Energy Technology Data Exchange (ETDEWEB)

Changes in the phosphate metabolism of the transplanted SCCVII (squamous cell carcinoma VII) tumor were studied before and after irradiation using in vivo [sup 31]P-magnetic resonance spectroscopy (MRS). Phosphocreatine (PCr), [gamma]-, [alpha]-, [beta]-ATP, inorganic phosphate (Pi), phosphomonoester (PME), and phosphodiester (PDE) were detected in [sup 31]P-MR spectra of tumor tissues. The curve fitting method was employed for calculating each peak of [sup 31]P-MR spectra (PCr, [beta]-ATP, Pi, PME, PDE). The values of PCr, PCr/Pi, [beta]-ATP/Pi and pH decreased in proportion to the growth of tumor, whereas that of Pi, PME and PDE increased. But the changes of [beta]-ATP were minimal in degree. Based on the fact that the ratio of PCr/Pi highly correlated with tumor volume and showed the most remarkable change among various parameters, it might be the useful index for the tumor growth. Because the phospholipid metabolite PME was detected in the ...

1992-03-01

198

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic ...

2010-11-21

199

Comparison of stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic neurinomas according to 3-D tumor volume shrinkage and quality of life  

International Nuclear Information System (INIS)

Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% (SRS), and 87.5%/87.2% (SRT). TV shrinkage was 15.1%/40.7% ...

2009-09-01

200

Brain mechanisms supporting the modulation of pain by mindfulness meditation.  

Science.gov (United States)

The subjective experience of one's environment is constructed by interactions among sensory, cognitive, and affective processes. For centuries, meditation has been thought to influence such processes by enabling a nonevaluative representation of sensory events. To better understand how meditation influences the sensory experience, we used arterial spin labeling functional magnetic resonance imaging to assess the neural mechanisms by which mindfulness meditation influences pain in healthy human participants. After 4 d of mindfulness meditation training, meditating in the presence of noxious stimulation significantly reduced pain unpleasantness by 57% and pain intensity ratings by 40% when compared to rest. A two-factor repeated-measures ANOVA was used to identify interactions between meditation and pain-related brain activation. Meditation reduced pain-related activation of the contralateral primary somatosensory cortex. ...

2011-04-01

201

Structure and magnetic properties of the UNi_1_0_-_xFe_xSi_2 system and "2"9Si nuclear magnetic resonance in UNi_1_0Si_2  

International Nuclear Information System (INIS)

Structure and magnetic properties of UNi_1_0_-_xFe_xSi_2 intermetallics and "2"9Si nuclear magnetic resonance (NMR) in UNi_1_0Si_2 are investigated in a wide temperature range. Solid solutions in the exactly single-phase tetragonal form, ThMn_1_2 type, exist for x<2. The Ni and Fe atoms occupy the 8(f), 8(i) and 8(j) positions statistically, whereas the U atoms occupy the 2(a) and the Si atoms the 8(j) sites. The lattice parameters roughly follow Vegard's law. The magnetic susceptibility does not exhibit Curie-Weiss behaviour and, at about 630 K, an anomaly in the temperature dependence is observed. At low temperature, other anomalies are observed at 32 K and 45 K, for x=0.5 and 1.0 respectively. These low temperature anomalies are probably connected with magnetic ordering of a ferromagnetic character, whereas that at 630 K might result from the superparamagnetic state of Ni. Two ...

1993-09-01

202

New 88Sr(n,g)Astrophysical Reaction Rate from Resonance Analysis of New High-Resolution Neutron Capture and Transmission Data  

Science.gov (United States)

Because of its small cross section, the 88Sr(n,g) reaction is an important bottleneck during s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. We have completed the resonance analysis of our new and improved measurements of the neutron capture and total cross sections for 88Sr made at the Oak Ridge Electron Linear Accelerator (ORELA). We describe our experimental procedures and resonance analysis, compare our results to previous data, and discuss their astrophysical impact.

1999-08-30

203

Design and experimental results on a terawatt magnetically controlled plasma opening switch  

Energy Technology Data Exchange (ETDEWEB)

The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at ...

1998-05-01

204

Application of GIS for the evaluation of human exposure to magnetic field in the vicinity of power lines  

Energy Technology Data Exchange (ETDEWEB)

Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.

1998-10-01

205

Low-frequency fields - sources and exposure; Niederfrequente Felder - Quellen und Exposition  

Energy Technology Data Exchange (ETDEWEB)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe) [Deutsch] Nach einer kurzen Diskussion der Begriffsdefinitionen und einer Einfuehrung in die Messtechnik werden die Charakteristika verschiedener ...

1993-06-01

206

Disturbance Rejection Control of an Electromagnetic Bearing Spindle  

Energy Technology Data Exchange (ETDEWEB)

The force exerted on the rotor by an active magnetic bearing (AMB) is determined by the current flow in the magnet coils. This force can be controlled very precisely, making magnetic bearings a potential benefit for grinding, where cutting forces act as external disturbances on the shaft, resulting in degraded part finish. It is possible to achieve precise shaft positioning, reduce vibration of the shaft caused by external disturbances, and even damp out resonant modes. Adaptive control is an appealing approach for these systems because the controller can tune itself to account for an unknown periodic disturbance, such as cutting or grinding forces, injected into the system. In this paper the authors show how one adaptive control algorithm can be applied to an AMB system with a periodic disturbance applied to the rotor. An adaptive algorithm was developed and implemented in both simulation and hardware, ...

2000-08-31

207

Anisotropic magnetism in hybridizing uranium systems  

International Nuclear Information System (INIS)

The isostructural uranium monopnictides and monochalcogenides have become prototype systems in actinide research with respect to their unusual magnetic properties. We have investigated the origins in the electronic structure of the variation in magnetic behavior as the degree of 5f-electron localization changes from localized to itinerant on going up the pnictogen or chalcogen column, thus decreasing the U-U separation. We have applied a synthesis of: (1) A phenomenological theory of orbitally driven magnetic ordering which includes both the hybridization-induced and the RKKY exchange interactions on an equal footing, and (2) Ab initio electronic structure calculations, based on the linear-muffin-tin-orbital method, allowing a first-principles evaluation of the parameters entering the model Hamiltonian. We have investigated systematically characteristic trends and changes of the 5f-state resonance ...

208

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data ...

209

Test Bed for Superconducting Materials  

Energy Technology Data Exchange (ETDEWEB)

Superconducting rf cavities are increasingly used in accelerators. Gradient is a parameter of particular importance for the ILC. Much progress in gradient has been made over the past decade, overcoming problems of multipacting, field emission, and breakdown triggered by surface impurities. However, the quenching limit of the surface magnetic field for niobium remains a hard limitation on cavity fields sustainable with this technology. Further exploration of materials and preparation may offer a path to surpassing the current limit. For this purpose, we have designed a resonant test cavity. One wall of the cavity is formed by a flat sample of superconducting material; the rest of the cavity is copper or niobium. The H field on the sample wall is 75% higher than on any other surface. Multipacting is avoided by use of a mode with no surface electric field. The cavity will be resonated through a coupling iris with high-power rf ...

2006-01-30

210

Study of praseodymium complexing with ethylenediaminetetraacetic acid by proton magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

The method of proton magnetic resonance (PMR) has been used to study the mechanism of reaction of complexing of paramagnetic Pr/sup 3 +/ ion with ethylenediaminetetra acetic acid (EDTA). The influence of medium acidity (pH5-12), EDTA/Pr ratio varying from 1 to 50, Pr/sup 3 +/ ion concentration (from 5x10/sup -3/ to 3x10/sup -1/ g-ion/l) and temperature (8-98 deg C) on chemical shifts and broadening of signals of EDTA molecule protons is investigated. Data on ratio of components, coordination and stability of forming complexes are obtained. The existence of two types of complexes with the Pr/EDTA ratio equal to 1:1 and 1:2 has been found. Equimolecular complex (1:1) is stable all over the studied temperature interval in contrast to the complex 1:2 for which at 50 deg C fast extrasphere exchange (Pr EDTA)EDTA * + EDTA/sup 0/ reversible (PrEDTA)EDTA/sup 0/ + EDTA * is observed, while at t=98 deg C intrasphere exchange (PrEDTA)EDTA * reversible ...

1983-05-01

211

Proton magnetic resonance spectroscopy reflects cellular proliferative activity in astrocytomas  

International Nuclear Information System (INIS)

We examined whether proton magnetic resonance spectroscopy (MRS) could provide accurate information on histological grade and cell proliferation in astrocytomas. We studied 23 patients with astrocytomas: five grade II, 10 grade III and eight with grade IV (glioblastoma multiforme). We performed proton MRS and determined the Ki-67 labeling index (LI), a tumour proliferation marker, in the same areas of the astrocytomas, and examined the statistical relationship between proton MRS and Ki-67 LI. The N-acetylaspartate (NAA)/creatine-phosphocreatine (Cr) and NAA/choline (Cho)-containing compound ratios were always significantly lower and the Cho/Cr ratios significantly higher than those for normal brain. The Cho/Cr ratio correlated positively and the NAA/Cho ratio inversely with Ki-67 LI. These findings suggest that the Cho signal in proton MRS reflects cellular proliferation. In Kaplan-Meier survival analysis, there was no significant difference ...

2000-05-01

212

Monitoring of the insecticide trichlorfon by phosphorus-31 nuclear magnetic resonance ({sup 31}P NMR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Trichlorfon is an organophosphorus insecticide, which is extensively being used for protection of fruit crops. Trichlorfon is a thermal labile compound, which cannot be easily determined by gas chromatography (GC) and has no suitable group for sensitive detection by high performance liquid chromatography (HPLC). In this study, a {sup 31}P nuclear magnetic resonance ({sup 31}P NMR) has been described for monitoring of trichlorfon without any separation step. The quantitative works of {sup 31}P NMR spectroscopy has been performed in the presence of an internal standard (hexamethylphosphoramide). Limit of detection (LOD) for this method has been found to be 55 mg L{sup -1}, without any sample preparation, and the linear working range was 150-5500 mg L{sup -1}. Relative standard deviation (R.S.D.%) of the method for three replicates within and between days was obtained {<=}9%. The average recovery efficiency was approximately 99-112%. This ...

2006-08-25

213

Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)  

International Nuclear Information System (INIS)

Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...

214

Magnetic resonance imaging of the hip with a pelvic phased-array surface coil: a technical note  

Energy Technology Data Exchange (ETDEWEB)

Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer phased-array surface coils ...

1998-02-01

215

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular regurgitation was easy to differentiate from ...

216

Magnetic resonance appearance of peripheral nerve sheath tumors  

International Nuclear Information System (INIS)

Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship between the lesions and the adjacent neurovascular structures and ...

217

Low field magnetic resonance imaging of femoral neck fractures  

International Nuclear Information System (INIS)

Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).

218

Contrasting Kondo behavior and resonant inverse photoemission spectra of CeTSi{sub 3} and CeTGe{sub 3} (T=Rh and Ir)  

Energy Technology Data Exchange (ETDEWEB)

We have investigated CeTSi{sub 3} and CeTGe{sub 3} (T = Rh and Ir) by measuring the magnetic susceptibility, specific heat, electrical resistivity, the resonant inverse photoemission (RIPES) and M{sub IV,V} x-ray absorption spectra (XAS). The germanides showed a very weak Kondo effect, but the silicides exhibited a negatively large Weiss temperature (approx. = -130 K) and a lnT dependence of magnetic resistivity above 100 K, suggesting that they are a Kondo-lattice compound with a high Kondo temperature T{sub K} (approx. = 100 K). The Curie-Weiss law suggests that Ce atoms in these compounds remain close to 3+ down to about 150 K in spite of their high T{sub K}. In general, both RIPES and M{sub IV,V} XAS support their apparently stable valency. (author)

1999-02-28

219

Characterization of proton exchange membrane materials for fuel cells by solid state nuclear magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel model gives the measured S/V ratios in the normal hydration ...

2010-03-15

220

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for ...

2010-10-01

221

A proton nuclear magnetic resonance investigation of the anion Bohr effect of human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution proton nuclear magnetic resonance spectroscopy has been used to investigate the molecular mechanism of the Bohr effect of human normal adult hemoglobin in the presence of two allosteric effectors, i.e., chloride and inorganic phosphate ions. The individual hydrogen ion equilibria of 22-26 histidyl residues of hemoglobin have been measured in anion-free 0.1 M HEPES buffer and in the presence of 0.18 M chloride or 0.1 M inorganic phosphate ions in both deoxy and carbonmonoxy forms. The results indicate that the #beta#2-histidyl residues are strong binding sites for chloride and inorganic phosphate ions in hemoglobin. The affinity of the #beta#2-histidyl residues for these anions is larger in the deoxy than in the carbonmonoxy form. Nevertheless, the contribution of these histidyl residues to the anion Bohr effect is small due to their low pK value in deoxyhemoglobin in anion-free solvents. The interactions of chloride and ...

222

Spontaneous and stimulated Raman studies of vibrational dephasing in condensed phases  

Energy Technology Data Exchange (ETDEWEB)

Vibrational dephasing in condensed phases is studied from both a theoretical and experimental standpoint. A theory is presented which describes the dynamics of motional or exchange processes in weakly perturbed systems. This general formalism, which has been previously used to describe motional narrowing in magnetic resonance, is applied to vibrational spectroscopy. The model treats the case of a high frequency vibration anharmonically coupled to a low-frequency vibration. Intermolecular exchange of low frequency vibrational quanta results in a temperature dependent broadening and frequency shift of the high frequency vibration. Analysis of experimental data by this model yields both the exchange rates and the anharmonic couplings.

1980-05-01

223

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

224

Quantum Computing with an Electron Spin Ensemble  

DEFF Research Database (Denmark)

We propose to encode a register of quantum bits in different collective electron spin wave excitations in a solid medium. Coupling to spins is enabled by locating them in the vicinity of a superconducting transmission line cavity, and making use of their strong collective coupling to the quantized radiation field. The transformation between different spin waves is achieved by applying gradient magnetic fields across the sample, while a Cooper pair box, resonant with the cavity field, may be used to carry out one- and two-qubit gate operations.

2009-01-01

225

Pure NQR quantum computing  

Energy Technology Data Exchange (ETDEWEB)

It is shown that pure NQR can be utilized as a platform for quantum computing without applying a high external magnetic field. By exciting each resonance transition between quadrupole energy levels with two radio-frequency fields differing in phase and direction, the double degeneracy of the spin energy spectrum in an electric field gradient is removed. As an example, in the case of I=7/2 (nuclei {sup 133}Cs or {sup 123}Sb) the energy spectrum has eight levels which can be used as three qubits. (orig.)

2002-07-01

226

Preparation and Properties of New Ester-Linked Cleavable Gemini Surfactants  

British Library Electronic Table of Contents (United Kingdom)

We have prepared a series of novel gemini surfactants having ester bonds in their structures. These surfactants possess two identical hydrophilic polyethylene glycol moieties, two hydrophobic alkyl group moieties, and an anionic spacer. The structures of these compounds were confirmed through infrared and nuclear magnetic resonance spectroscopic and elemental analyses. The novel gemini surfactants exhibit excellent surface activity in terms of their surface tension, low-foaming, wetting power, and fluorescence properties. The presence of the ester linkages made these structures cleavable surfactants.

2011-01-01

227

Molecular accessibility in solvent swelled coal. Quarterly report  

Energy Technology Data Exchange (ETDEWEB)

To expand the information base on molecular accessibility in solvent swelled coal, Argonne Premium Coal Samples (APCS) were swelled in polar, basic solvents before and after moisture loss and upon air oxidation. So far studies have been reported on the changes in pore size distribution as a function of temperature when polar basic swelling solvents are used. Additional studies employing EPR spin probe techniques performed on the breaking up of the hydrogen bonding between bedding planes were later confirmed by magnetic resonance imaging at Argonne National Lab and the University of Illinois.

1992-11-01

228

Magnetic resonance imaging of the pediatric brain  

International Nuclear Information System (INIS)

The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.

229

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

230

IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT  

British Library Electronic Table of Contents (United Kingdom)

Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.

2011-01-01

231

Enriched lithium collection from lithium plasma flow  

International Nuclear Information System (INIS)

In order to understand the physical processes concerned with the selective heating by ion cyclotron resonance and with the subsequent collection of heated particles, experiments were carried out with the extraction of lithium samples, enriched with "6Li isotopes. Probe and integral extractors allow to collect enriched Li at the end of the selective heating region. Surface density distribution on the collector and local isotopic content of lithium are measured, as a function of the screen height and the retarding potential. Dependence of the collected amount of lithium and of its isotopic content on the value of the magnetic field is also measured. 4 figs., 2 tabs., 5 refs.

232

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

233

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

234

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.  

Science.gov (United States)

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737

2006-12-19

235

Summary of the report of the Senior Committee on Environmental, Safety, and Economic Aspects of Magnetic Fusion Energy  

Energy Technology Data Exchange (ETDEWEB)

The Senior Committee on Environmental, Safety, and Economic Aspects of Magnetic Fusion Energy (ESECOM) has assessed magnetic fusion energy's prospects for providing energy with economic, environmental, and safety characteristics that would be attractive compared with other energy sources (mainly fission) available in the year 2015 and beyond. ESECOM gives particular attention to the interaction of environmental, safety, and economic characteristics of a variety of magnetic fusion reactors, and compares them with a variety of fission cases. Eight fusion cases, two fusion-fission hybrid cases, and four fission cases are examined, using consistent economic and safety models. These models permit exploration of the environmental, safety, and economic potential of fusion concepts using a wide range of possible materials choices, power densities, power conversion schemes, and fuel ...

1987-09-10

236

Radiation and thermal analysis of superconducting quadrupoles in the interaction region of linear collider  

Energy Technology Data Exchange (ETDEWEB)

CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.

2008-06-01

237

Quark-Hadron Duality in Spin Structure Functions $g_1^p$ and $g_1^d$  

Energy Technology Data Exchange (ETDEWEB)

New measurements of the spin structure functions of the proton and deuteron g{sub 1}{sup p}(x, Q{sup 2}) and g{sub 1}{sup d}(x, Q{sup 2}) in the nucleon resonance region are compared with extrapolations of target-mass-corrected next-to-leading-order (NLO) QCD fits to higher energy data. Averaged over the entire resonance region (W < 2 GeV), the data and QCD fits are in good agreement in both magnitude and Q{sup 2} dependence for Q{sup 2} > 1.7 GeV{sup 2}/c{sup 2}. This ''global'' duality appears to result from cancellations among the prominent ''local'' resonance regions: in particular strong {sigma}{sub 3/2} contributions in the {Delta}(1232) region appear to be compensated by strong {sigma}{sub 1/2} contributions in the resonance region centered on 1.5 GeV. These results are encouraging for the extension ...

2006-07-25

238

IR double-resonance spectroscopy applied to the 4-aminophenol(H{sub 2}O){sub 1} cluster  

Energy Technology Data Exchange (ETDEWEB)

The IR double-resonance techniques IR/R2PI (infrared/resonant 2-photon ionization), IR/PIRI (infrared-photo-induced Rydberg ionization) and IR-photodissociation spectroscopy are valuable tools to investigate structure, vibrations, and dynamical processes of neutral and ionic hydrogen-bonded clusters containing aromatic molecules. In this paper we report on the application of the IR double-resonance techniques to determine the NH and OH stretching vibrations of 4-aminophenol and 4-aminophenol(H{sub 2}O){sub 1}, both in the neutral (S{sub 0}) and ionic (D{sub 0}) ground state. All vibrational frequencies obtained for 4-aminophenol and the cluster are compared with the values obtained from ab initio and DFT calculations. In the S{sub 0} state, a trans-linear arrangement of 4-aminophenol(H{sub 2}O){sub 1} is obtained containing an O-H. O hydrogen bond. In the D{sub 0} state an overlay of two spectra can be ...

2001-03-01

239

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The ...

2001-04-01

240

Menstrual variation of breast volume and T{sub 2} relaxation times in cyclical mastalgia  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Hormonal activity causes breast volume to change during the menstrual cycle. One possible cause of this volume change is thought to be due to water retention or oedema within the tissues. We used magnetic resonance imaging (MRI) to study the variation in breast volume and {sup 1}H Magnetic Resonance Spectroscopy (MRS) to measure T{sub 2} relaxation times which are known to increase with increasing tissue water content. We hypothesised that an increase in breast volume will elevate T{sub 2} relaxation due to the presence of an increased water content within the breast. T{sub 2} Relaxation time and volume were studied in fifteen control subjects and in a cohort of eight patients with cyclical mastalgia in order to determine whether changes in breast volume and T{sub 2} relaxation times differed in controls and patients during menses, ovulation and premenses. Method: Breast volume was determined ...

2008-02-15

241

"1H and "3"1P nuclear magnetic resonance investigation of the interaction between 2,3-diphosphoglycerate and human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution "1H and "3"1P nuclear magnetic resonance spectroscopy has been used to investigate the binding of 2,3-diphosphoglycerate to human normal adult hemoglobin and the molecular interactions involved in the allosteric effect of the 2,3-diphosphoglycerate molecule on hemoglobin. Individual hydrogen ion NMR titration curves have been obtained for 22-26 histidyl residues of hemoglobin and for each phosphate group of 2,3-diphosphoglycerate with hemoglobin in both the deoxy and carbonmonoxy forms. The results indicate that 2,3-diphosphoglycerate binds to deoxyhemoglobin at the central cavity between the two #beta# chains and the binding involves the #beta#2-histidyl residues. Moreover, the results suggest that the binding site of 2,3-diphosphoglycerate to carbonmonoxyhemoglobin contains the same (or at least some of the same) amino acid residues responsible for binding in the deoxy form. As a result of the specific interactions with ...

242

Time-varying magnetic fields increase cytosolic free Ca sup 2+ in HL-60 cells  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic fields have been reported to cause a variety of biological effects. It has been hypothesized that many of these phenomena are mediated by a primary effect on the concentration of cytosolic free calcium ((Ca2+)i). We investigated the effects of exposure to electromagnetic fields on (Ca2+)i in HL-60 cells using the Ca2(+)-sensitive fluorescent indicator indo-1. Indo-1-loaded cell samples were exposed to a radiofrequency electromagnetic field, a static magnetic field, and a time-varying magnetic field, which were generated by a magnetic resonance imaging (MRI) unit. We found that a 23-min exposure to all three fields, in combination, induced a significant increase in (Ca2+)i of 31 +/- 8 (SE) nM (P less than 0.01, n = 13) from a basal level of 121 +/- 8 nM. Also, cells exposed to only the time-varying magnetic field had a mean (Ca2+)i that was 34 +/- 10 nM (P less than ...

1990-10-01

243

Horizontal vibration suppression method suitable for super-high-speed elevators; Chokosoku elevator ni tekishita kago yokoshindo yokusei hoshiki  

Energy Technology Data Exchange (ETDEWEB)

Horizontal vibrations of elevator cars mainly occur because a car swings as roller guides installed at corners of a car frame move on a winding guide rail at high speeds. Rider comfort in high speed elevators is worsened by these vibrations. Conventional active dampers suppressing horizontal vibrations using ac servo motors make cars heavier so driving power becomes larger, and they are not easily applied to existing elevators. An active damping control method suited to super-high-speed elevators is which can solve these problems. The method suppresses vibrations by generating only enough magnetic force needed to suppress them only when vibrations of the car franc are produced. The vibrations are detected using acceleration detectors and magnets installed on left and right sides of the car frame. A computer simulator was made to analyze phenomena of car vibrations and to verify effects of the proposed magnetic damping ...

1998-03-01

244

Moessbauer investigation of the magnetic anisotropy and electronic structure of a metallic glass  

International Nuclear Information System (INIS)

The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).

245

Independent superconductivity and paramagnetism in HoBa/sub 2/Cu/sub 3/O/sub z/  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of the superconductive materials HoBa/sub 2/Cu/sub 3/O/sub z/ and YBa/sub 2/Cu/sub 3/O/sub z/ have been measured and compared. Both had superconductive transition temperatures T/sub c/ in low magnetic fields near 90 K and exhibited nearly complete magnetic-flux exclusion. The susceptibility of the Ho-based materials followed a Curie-Weiss law both above and below T/sub c/. These results give clear experimental evidence for a nearly complete decoupling of the magnetic and superconductive layers, demonstrating that the superconductivity is highly anisotropic.

1987-07-01

246

High-field magnetization of CeRh{sub 2}Si{sub 2} and CePd{sub 2}Si{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

High-field magnetization properties of single crystalline CeRh{sub 2}Si{sub 2} and CePd{sub 2}Si{sub 2} were investigated. Two-step metamagnetic transition (H{sub c1}=25.4 T and H{sub c2}=26.0 T) was observed in the case of CeRh{sub 2}Si{sub 2}, whereas no anomaly was found in the magnetization process of CePd{sub 2}Si{sub 2} up to 28 T. The mean field analysis has shown that CeRh{sub 2}Si{sub 2} is quite anisotropic compared to CePd{sub 2}Si{sub 2}, which results in the sharp contrast between the magnetization processes of the two compounds.

1998-07-01

247

High-field magnetization of CeRh_2Si_2 and CePd_2Si_2  

International Nuclear Information System (INIS)

High-field magnetization properties of single crystalline CeRh_2Si_2 and CePd_2Si_2 were investigated. Two-step metamagnetic transition (H_c_1=25.4 T and H_c_2=26.0 T) was observed in the case of CeRh_2Si_2, whereas no anomaly was found in the magnetization process of CePd_2Si_2 up to 28 T. The mean field analysis has shown that CeRh_2Si_2 is quite anisotropic compared to CePd_2Si_2, which results in the sharp contrast between the magnetization processes of the two compounds

1997-08-04

248

Effects of velocity-dependent force on the magnetic form factors of odd-Z  

International Nuclear Information System (INIS)

We investigate the effects of the velocity-dependent force on the magnetic form factors and magnetic moments of odd-Z nuclei. The form factors are calculated with the harmonic-oscillator wavefunctions. It is found that the contributions of the velocity-dependent force manifest themselves in the very large momentum transfer region (q?4 fm-1). In the low and medium q region the contributions of the velocity-dependent force are very small compared with those without this force. However, in the high-q region the contributions of the velocity-dependent force are larger than the normal form factors. The diffraction structures beyond the existing experimental data are found after the contributions of the velocity-dependent force are included. The formula of the correction to the single particle magnetic moment due to the velocity-dependent force is reproduced exactly in the long-wavelength limit (q=0) of the ...

2008-03-01

249

DFT study of structure?properties correlations in [MnTPP][TCNE] quasi-one-dimensional molecular magnets  

British Library Electronic Table of Contents (United Kingdom)

We report the first band structure calculations of the quasi-one-dimensional [MnTPP][TCNE] compounds (TPP?=?meso-tetraphenylporphyrinato, TCNE?=?tetracyanoethylene), based on Density Functional Theory (DFT) methods, in order to interpret the magnetic ordering in these prototypic systems. We compare and contrast the results of broken-symmetry DFT calculations for extended systems, with periodic boundary conditions, and for finite systems, magnetic dimers modeling the actual molecular magnets. By varying systematically the main angles, we are able to determine the geometry dependence of the exchange interaction. Structure?properties correlations in these charge-transfer salts reveal the determinant role of the Mn-(N?C)TCNE bond angle on the strength of the ferrimagnetic coupling between the ...

2011-01-01

250

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed ...

2002-05-01

251

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold ...

2003-12-01

252

Spectrograph for free-electron laser experiments  

International Nuclear Information System (INIS)

The design and construction of a Browne-Buechner type round pole face magnetic electron spectrograph is described. The design is based on the first order transfer properties of the bending magnet including the focal surface, dispersion, magnification and resolution. Second order aberrations are compared wit numerical ray tracing results using measured field data to simulate the magnet. The numerical results are also compared with floating wire measurements on the system. Agreement is within one part in 10"4. Data extraction from the instrument is done with an array of copper detectors placed along the focal surface. The spectrograph has been successfully employed in free-electron laser (FEL) experiments for over a year.

1983-03-21

253

Spontaneous Radiation Emission from Short, High Field Strength Insertion Devices  

Energy Technology Data Exchange (ETDEWEB)

Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In ...

2005-09-15

254

T{sub 1} and T{sub 2} relaxivities of succimer-coated MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

Energy Technology Data Exchange (ETDEWEB)

Superparamagnetic MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r{sub 2}/r{sub 1}, for MnFe{sub 2}O{sub 4}, Fe{sub 3}O{sub 4} and CoFe{sub 2}O{sub 4} were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T{sub 2} contrast agents for MRI.

2009-12-15

255

T1 and T2 relaxivities of succimer-coated MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

International Nuclear Information System (INIS)

Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.

2009-12-01

256

Remodeling of the free electron laser with the L-band linac at Osaka University  

International Nuclear Information System (INIS)

The far infrared free electron laser (FEL) has been being developed since 1990 using the L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. The first lasing was obtained in 1994 at wavelengths from 32 to 40 #mu#m. The FEL is now being modified suitable for user experiments. The wiggler with a fixed magnet gap used in the original FEL has been remodeled to make the magnet gap variable. In order to optimize the variable range of the gap, the gain and the diffraction loss were calculated. The peak gain is calculated to be 270% and the diffraction loss to be 22% at 150 #mu#m. The wavelength is expected to be variable from 25 up to at least 150 #mu#m. The two bending magnets in the optical resonator have been remodeled and the vacuum chambers with larger vertical sizes for them have been newly made so that the diffraction loss in these parts becomes smaller than ...

1997-02-28

257

Radio Frequency Plasma Applications for Space Propulsion  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ...

1999-09-13

258

Pion-nucleon charge exchange amplitudes above 2 GeV  

Energy Technology Data Exchange (ETDEWEB)

The amplitudes for the pion-nucleon charge exchange reaction of the Karlsruhe-Helsinki and the George-Washington-University partial-wave analyses are compared with those of a Regge-cut model with the aim to explore the possibility to provide high-energy constraints for theoretical baryon resonance analyses in the energy region above 2 GeV. (orig.)

2009-04-15

259

Light emission from grazing incidence interaction of light ions with clean Cu(110)  

International Nuclear Information System (INIS)

Photon yields were measured from Cu(110) bombarded by H"+, H_2"+ and He"+ with different energies. The energy dependence is different from previous studies at perpendicular incidence. A calculation of the energy dependence of resonant charge capture into the n=3 state of H is compared with experiment. (G.Q.).

1983-02-04

260

Validation of the GROMOS force-field parameter set 45A3 against nuclear magnetic resonance data of hen egg lysozyme  

Energy Technology Data Exchange (ETDEWEB)

The quality of molecular dynamics (MD) simulations of proteins depends critically on the biomolecular force field that is used. Such force fields are defined by force-field parameter sets, which are generally determined and improved through calibration of properties of small molecules against experimental or theoretical data. By application to large molecules such as proteins, a new force-field parameter set can be validated. We report two 3.5 ns molecular dynamics simulations of hen egg white lysozyme in water applying the widely used GROMOS force-field parameter set 43A1 and a new set 45A3. The two MD ensembles are evaluated against NMR spectroscopic data NOE atom-atom distance bounds, {sup 3}J{sub NH{alpha}} and {sup 3}J{sub {alpha}}{sub {beta}} coupling constants, and {sup 1}5N relaxation data. It is shown that the two sets reproduce structural properties about equally well. The 45A3 ensemble fulfills the atom-atom distance bounds derived from NMR spectroscopy slightly less well ...

2004-12-15

261

Inflammatory spine disease as a cause of back pain; Entzuendliche Wirbelsaeulenerkrankungen als Ursache fuer Rueckenschmerzen  

Energy Technology Data Exchange (ETDEWEB)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-{alpha} antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-{alpha} antagonists is based on clinical and laboratory criteria, and signs of ...

2006-06-15

262

In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves  

DEFF Research Database (Denmark)

BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native valves had a significantly lower peakvelocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 ...

2010-01-01

263

Comparison of histological findings and parathyroid scintigraphy in hemodialysis patients with secondary hyperparathyroid glands  

International Nuclear Information System (INIS)

The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. ...

2005-04-01

264

/sup 18/O isotope effect in carbon-13 nuclear magnetic resonance spectroscopy. Part 8. Oxygen exchange of 2,4,6-trimethylpyrylium cation  

Energy Technology Data Exchange (ETDEWEB)

The rate of the oxygen-exchange reaction in an aqueous solution of a heterocyclic oxygen compound, 2,4,6-trimethylpyrylium perchlorate, was quantitated. The /sup 18/O isotope effect in /sup 13/C NMR spectroscopy affords a direct, continuous, and relatively simple analysis of the reaction and was used to obtain data on the incorporation of /sup 18/O from solvent H/sub 2//sup 18/O into the pyrylium salt. Due to the low solubility of this salt in aqueous solutions, 2,4,6-trimethyl(2-/sup 13/C)pyrylium perchlorate and 2,4,6-trimethyl(2,6-/sup 13/C/sub 2/)pyrylium perchlorate were synthesized to facilitate the acquisition of the data on an NTC-200 spectrometer operating at 50.31 MHz. Upon incorporation of /sup 18/O into the pyrylium salt, the /sup 13/C NMR signal of the directly bonded carbon atom is shifted upfield 0.038 ppm. A /sup 13/C isotope effect is also detected in the doubly /sup 13/C-enriched pyrylium salt where the /sup 13/C NMR signal for /sup 13/C-O-/sup 13/C appears 0.011 ppm ...

1984-12-12

265

Ferroelectric and magnetic properties of Ho{sub 2}CuTiO{sub 6} double perovskite  

Energy Technology Data Exchange (ETDEWEB)

Ho{sub 2}CuTiO{sub 6} double pervoskite is synthesized by solid state reaction method and the phase formation was confirmed by X-ray diffraction. Ho{sub 2}CuTiO{sub 6} crystallizes in space group P63 cm and are isostructural in AMnO{sub 3} structure. We have investigated the effect of the presence of a magnetic ion (Ho{sup 3+}{approx}10.4{mu}{sub B}) in Ho{sub 2}CuTiO{sub 6}, on the magnetic properties, compared to that of an isostructural double perovskite containing Y-ion (non-magnetic), i.e., Y{sub 2}CuTiO{sub 6}. Magnetization measurements on Ho{sub 2}CuTiO{sub 6} showed paramagnetic moment of 0.026{mu}{sub B}/Ho at room temperature in an applied field of 7 T although no saturation is observed at room temperature, whereas, at 5 K, the paramagnetic moment was 0.3{mu}{sub B}/Ho in the same field. Since this compound is non-centrosymmetric, it is of interest to look into the ...

2006-08-15

266

Absorption Features in Spectra of Magnetized Neutron Stars  

CERN Document Server

The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the observations can be ...

2010-01-01

267

Pituitary disease in childhood: utility of magnetic resonance; Patologia hipofisaria en la edad pediatrica: unidad de la resonance magnetica  

Energy Technology Data Exchange (ETDEWEB)

To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children with ...

2000-07-01

268

Very high resolution measurements of the total cross section of natural iron  

Energy Technology Data Exchange (ETDEWEB)

The total cross section of natural Fe has been measured with the GELINA pulsed white neutron source with a time-of-flight resolution of about 3.8 ps/m and good statistical precision. Measurements have been performed on three sample thicknesses including one with an average transmission of 0.1, in order to check for consistency and for remaining resolution effects. The cross sections in the {open_quotes}unresolved resonance region{close_quotes} still show rather strong fluctuations. These data will directly be used in shielding benchmark calculations. The resonance region data will be analysed by an R-matrix routine and the parameters be compared to existing compilations.

1994-12-31

269

Transmission nuclear resonance fluorescence measurements of "2"3"8U in thick targets  

International Nuclear Information System (INIS)

Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86g/cm"2. The "2"3"8U content in the targets varied from 0% to 8.5% (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to the average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter "2"3"8U measurements indicates general agreement in observed excited states. Evidence of two new "2"3"8U excited states and possibly a third state have also been observed.

2011-05-15

270

The phase and pole structure of the N{sup *}(1535) in {pi}N{yields}{pi}N and {gamma}N{yields}{pi}N  

Energy Technology Data Exchange (ETDEWEB)

The nature of some baryonic resonances is still an unresolved issue. The case of the N{sup *}(1535) is particularly interesting in this respect due to the nearby {eta} N threshold and interference with the N{sup *}(1650). The N{sup *}(1535) has been described as a threshold effect, as a genuine 3-quark resonance, or as dynamically generated from the interaction of the octet of baryons with the octet of mesons. In the scheme of dynamical generation, predictions for the interaction of the N{sup *}(1535) with the photon can be made. In this study, we simultaneously analyze the role of the N{sup *}(1535) in the {pi}N{yields}{pi}N and {gamma}N{yields}{pi}N reactions and compare to the respective amplitudes from partial-wave analyses. This test is very sensitive to the meson-baryon components of the N{sup *}(1535). (orig.)

2010-01-15

271

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

272

On the performance of surface plasmon resonance based fibre optic sensor with different bimetallic nanoparticle alloy combinations  

Energy Technology Data Exchange (ETDEWEB)

In this work, we have investigated the capability of different bimetallic nanoparticle alloy combinations to be used in fibre optic sensors based on the technique of surface plasmon resonance. The metals considered for this analysis are silver, gold, copper and aluminium. The performance of the sensor with different bimetallic nanoparticle alloy combinations is evaluated and compared numerically. The performance is analysed in terms of three parameters: sensitivity, signal-to-noise ratio (SNR) and operating range for the sensing layer refractive index values. On the basis of the comparison and some logistic criteria, the best possible bimetallic alloy combinations along with a requisite alloy composition ratio are predicted. The bimetallic nanoparticle alloy combination is capable of simultaneously providing larger values of sensitivity, SNR and operating range, which is not possible with any single metallic nanoparticle layer.

2008-03-07

273

Absolute cross sections for near-threshold electron-impact excitation of the 3s"2"1S#->#3s3p"1P and 3s"2"1S#->#3s3p"3P transitions in Si"2"+  

International Nuclear Information System (INIS)

Absolute total cross sections for electron-impact excitation of the 3s"2"1S#->#3s3p"3P and 3s"2"1S#->#3s3p"1P transitions in Si"2"+ were measured using the merged electron-ion beams energy-loss technique. The results are compared to R-matrix close-coupling theory, which predicts a strong resonance enhancement of the cross section near the threshold for excitation of the "3P state and this is confirmed by the experiments. The observed disagreement between theory and experiment for the dipole excitation is suggested to be due to resonance interference. copyright 1997 The American Physical Society.

274

A Simple Scheme for Realizing a Multiqubit Controlled-Phase Gate Through a Resonant Interaction of Three-Level Atoms with a Single-Mode Cavity  

International Nuclear Information System (INIS)

A very simple theoretical scheme is proposed to implement two- and three-qubit controlled-phase gates firstly only using a single resonant interaction between ladder-type three-level atoms and the single-mode cavity. In the presented protocol, the quantum information is encoded on the stable ground states of the atoms (as the controlling qubits) and the zero- and one-photon Fock states of cavity-field (as the target qubit). Under the influence of the atomic spontaneous emission, the decay of the cavity-mode, and deviation of the coupling strength, the three-qubit controlled-phase gate may have a comparatively high fidelity. The experimental feasibility of controlled-phase gate and the case that is extended to realize N-qubit controlled-phase gate are also discussed. (general)

2010-03-15

276

Physical basis of the effect of hemoglobin on the "3"1P NMR chemical shifts of various phosphoryl compounds  

International Nuclear Information System (INIS)

The marked difference between the intra- and extracellular "3"1P NMR chemical shifts of various phosphoryl compounds when added to a red cell suspension may be largely understood in terms of the effects of hemoglobin on the "3"1P NMR chemical shifts. The presence of [oxy- or (carbonmonoxy)-] hemoglobin inside the red cell causes the bulk magnetic susceptibility of the cell cytoplasm to be significantly less than that of the external solution. This difference is sufficient to account for the difference in the intra- and extracellular chemical shifts of the two phosphate esters trimethyl phosphate and triethyl phosphate. However, in the case of the compounds dimethyl methylphosphonate, diethyl methylphosphonate, and trimethylphosphine oxide as well as the hypophosphite, phenylphosphinate, and diphenylphosphinate ions, hemoglobin exerts an additional, much larger, effect, causing the "3"1P NMR resonances to shift to lower frequency in a manner ...

277

Nuclear magnetic resonance spectroscopy in the structure elucidation and biosynthesis of natural products  

Energy Technology Data Exchange (ETDEWEB)

Examination of a chloroform extract of Dracaena loureiri Gagnep (Agavaceae), a Thia medicinal plant possessing antibacterial activity, has led to the isolation of fifteen flavenoids. The biogenic relationships among these flavenoids isolated were briefly discussed. Definition of the skeleton and the unambiguous assignment of all of the protons of the isolates was achieved through extensive 2D-homonuclear chemical shift correlation, nuclear Overhauser effect (NOE) difference spectroscopy and 2D-NOE experiments. The {sup 1}H and {sup 13}C NMR spectra of staurosporine, a potent biologically active agent from Streptomyces staurosporeus, were unambiguously assigned by using 2D homonuclear chemical shift correlation, NOE, {sup 1}H-detected heteronuclear multiple-quantum coherence via direct coupling and via multiple-bond coupling for resonance assignments of protonated and nonprotonated carbons, respectively. S. Staurosporeus was found to utilize endogenous and exogenous ...

1988-01-01

278

Free electron laser  

International Nuclear Information System (INIS)

The present article outlines major features of the free electron laser (FEL) and reviews research and development of FEL. Relations among the oscillation frequency, electron beam parameters and wiggler parameters, the physical mechanism of amplification and the physical process of saturation are discussed to identify the difference between FEL and other lasers. The report also outlines techniques for accelerators which are used to generate high-quality, high-energy electron beams required for FEL experiments. Techniques to achieve a short wavelength, high output and high efficiency, and applications of FEL are also discussed. FEL consists of an electron accelerator, wiggler and optical resonator. In FEL, electron beams with a relativistic energy interact resonantly with an electromagnetic field to generate coherent electromagnetic waves. Unlike conventional lasers, FEL does not surfer from restrictions on its oscillation frequency associated ...

279

Comparative study on the critical current performance of Bi-2223/Ag and YBCO wires in low magnetic fields at liquid nitrogen temperature  

Science.gov (United States)

A comparative study on the critical current performance of Bi-2223/Ag and YBCO coated conductor wires in low magnetic fields at liquid nitrogen temperature was carried out in this work. Five commercial high temperature superconductor wires from different manufacturers were collected. Their critical currents were measured in magnetic fields, ranging from 0 to 0.4 T. On contrary to the common conception, the Bi-2223/Ag samples had better performance than YBCO coated conductor samples in the magnetic fields parallel to the wide surface of superconducting wires within the experimental scope. We also found similar results by collecting the concerned datum from the published literatures to confirm our measurement results. At the present stage, this fact made that the Bi-2223/Ag wires might be the preferred choice for the applications with mainly low parallel fields involved, unless other considerations were ...

2011-05-01

280

Longitudinal impedance and wake from XFEL undulators. Impact on current-enhanced SASE schemes  

British Library Electronic Table of Contents (United Kingdom)

In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to deriv...

2007-01-01

281

S-shaped magnetic macroparticle filter for cathodic arc deposition  

Energy Technology Data Exchange (ETDEWEB)

A new magnetic macroparticle filter design consisting of two 90{sup o} filters forming an S-shape is described. Transport properties of this S-filter are investigated using Langmuir and deposition probes. It is shown that filter efficiency is product of the efficiencies of two 90{sup o} filters and the deposition rate is still acceptably high to perform thin film deposition. Films of amorphous hard carbon have been deposited using a 90{sup o} filter and the S-filter, and macroparticle content of the films are compared.

1996-04-01

282

Operation principle of microsecond plasma opening switches  

International Nuclear Information System (INIS)

Closing and breaking of current in microsecond megaampere plasma opening switches are considered. Conductivity current scaling in the switch due to plasma acceleration by a magnetic piston is discussed and compared with experimental data. Two ways of determining the width of a current channel are taken up. This channel results from the diffusion of the magnetic field in the plane of the piston followed by the convective ejection of the field frozen in the accelerated plasma flow behind the shock wave into the bridge. Based on experimental data, a scaling law for the voltage on the switch according to the switch parameters is derived. The problem of reverse closing, which limits the efficiency of storage energy extraction into the load, is considered

2009-01-01

283

Calculations of the self-amplified spontaneous emission performance of a free-electron laser.  

Energy Technology Data Exchange (ETDEWEB)

The linear integral equation based computer code (RON: Roger Oleg Nikolai), which was recently developed at Argonne National Laboratory, was used to calculate the self-amplified spontaneous emission (SASE) performance of the free-electron laser (FEL) being built at Argonne. Signal growth calculations under different conditions are used for estimating tolerances of actual design parameters. The radiation characteristics are discussed, and calculations using an ideal undulator magnetic field and a real measured magnetic field will be compared and discussed.

1999-04-20

284

Value of MRCP using oral Gd-DTPA as negative contrast materials in diagnosis of atypical juxtapapillary duodenal diverticulum  

British Library Electronic Table of Contents (United Kingdom)

Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imaging findings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...

2009-01-01

285

The role of MRI in the diagnosis of recurrent/persistent carpal tunnel syndrome: A radiological and intra-operative correlation  

British Library Electronic Table of Contents (United Kingdom)

MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...

2011-01-01

286

The influence of normal human ageing on automatic movements  

British Library Electronic Table of Contents (United Kingdom)

There is evidence that aged normal subjects have more difficulty in achieving automaticity than young subjects. The underlying central neural mechanism for this phenomenon is unclear. In the present study, functional magnetic resonance imaging (fMRI) was used to investigate the effect of normal ageing on automaticity. Aged healthy subjects were asked to practice self-initiated, self-paced, memorized sequential finger movements with different complexity until they could perform the tasks automatically. Automaticity was evaluated by having subjects perform a secondary task simultaneously with the sequential movements. Although it took more time, most aged subjects eventually performed the tasks automatically at the same level as the young subjects. Functional MRI results showed that, for bot...

2005-01-01

287

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

288

Study of the cyclotron feature in MXB 0656-072  

CERN Document Server

We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.

2006-01-01

289

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

290

Primary and multisensory cortical activity is correlated with audiovisual percepts  

British Library Electronic Table of Contents (United Kingdom)

Incongruent auditory and visual stimuli can elicit audiovisual illusions such as the McGurk effect where visual /ka/ and auditory /pa/ fuse into another percept such as/ta/. In the present study, human brain activity was measured with adaptation functional magnetic resonance imaging to investigate which brain areas support such audiovisual illusions. Subjects viewed trains of four movies beginning with three congruent /pa/ stimuli to induce adaptation. The fourth stimulus could be (i) another congruent /pa/, (ii) a congruent /ka/, (iii) an incongruent stimulus that evokes the McGurk effect in susceptible individuals (lips /ka/ voice /pa/), or (iv) the converse combination that does not cause the McGurk effect (lips /pa/ voice/ ka/). This paradigm was predicted to show increased release fro...

2010-01-01

291

Preliminary studies on the chemical characterization and antioxidant properties of acidic polysaccharides from Sargassum fusiforme  

British Library Electronic Table of Contents (United Kingdom)

In order to investigate the antioxidant properties of the polysaccharides from the brown alga Sargassum fusiforme, the crude polysaccharides from S. fusiforme (SFPS) were extracted in hot water, and the lipid peroxidation inhibition assay exhibited that SFPS possessed a potential antioxidant activity. Hence, two purely polymeric fractions, SFPS-1 and SFPS-2 were isolated by the column of DEAE (2-diethylaminoethanol)-Sepharose Fast Flow, with their molecular weights of 51.4 and 30.3 kDa determined by high performance gel permeation chromatography (HPGPC). They were preliminarily characterized using chemical analysis in combination of infrared (IR) and nuclear magnetic resonance (NMR) spectroscopies and found to contain large amounts of uronic acids and ?-glycosidical linkages. The antioxida...

2008-01-01

292

Point defects in dilute nitride III-N-As and III-N-P  

International Nuclear Information System (INIS)

We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.

2006-04-01

293

Oxidation of polycaprolactone to induce compatibility with other degradable polyesters  

British Library Electronic Table of Contents (United Kingdom)

Chemical modification of poly(?-caprolactone) PCL by oxidation with potassium permanganate in solution was investigated. According to the data obtained from Fourier transform infrared spectroscopy (FT-IR) and nuclear magnetic resonance 1H NMR, after the oxidation reactions the PCL chains exhibited new functional groups (vinyl and hydroxyl) and possible intermolecular recombination, producing an oxidized-polycaprolactone (PCL-OX). Solution viscometry indicated that degradation also occurred during the oxidation reactions (30% drop in viscosity average molecular weight was detected). Differential scanning calorimetry (DSC) also indicated that PCL was chemically modified and degraded. The successive self-nucleation/annealing (SSA) treatment confirmed that a reduction (or interruption) in line...

2007-01-01

294

Mapping subcortical diffusivity. Application to brain development. Presidential award proceeding  

International Nuclear Information System (INIS)

We studied age-related microstructural changes in the subcortical white matter from adolescence to middle age in 16 healthy male subjects (age range: 12 to 47 years) using diffusion-weighted magnetic resonance (MR) imaging (DWI). Mean diffusivity (MD) of subcortical white matter was mapped onto the overlying cortical surface using our original method. The mean MD values within 76 cortical regions were measured using atlas-based gray matter segmentation and then correlated with age. A significant negative correlation with age was observed in subcortical MD values in several cortical regions, primarily over the bilateral temporal and occipital lobes. Our results demonstrated subcortical microstructural change in postadolescence that may reflect continuing myelination. (author)

2007-01-01

295

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

296

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

297

Influence of attention focus on neural activity in the human spinal cord during thermal sensory stimulation  

British Library Electronic Table of Contents (United Kingdom)

Perceptions of sensation and pain in healthy people are believed to be the net result of sensory input and descending modulation from brainstem and cortical regions depending on emotional and cognitive factors. Here, the influence of attention on neural activity in the spinal cord during thermal sensory stimulation of the hand was investigated with functional magnetic resonance imaging by systematically varying the participants' attention focus across and within repeated studies. Attention states included (1) attention to the stimulus by rating the sensation and (2) attention away from the stimulus by performing various mental tasks of watching a movie and identifying characters, detecting the direction of coherently moving dots within a randomly moving visual field and answering mentally-...

2011-01-01

298

Fetal MRI of pathological brain development  

International Nuclear Information System (INIS)

Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)

2006-02-01

299

Experimental parameterization of an energy function for the simulation of unfolded proteins  

DEFF Research Database (Denmark)

The determination of conformational preferences in unfolded and disordered proteins is an important challenge in structural biology. We here describe an algorithm to optimize energy functions for the simulation of unfolded proteins. The procedure is based on the maximum likelihood principle and employs a fast and efficient gradient descent method to find the set of parameters of the energy function that best explain the experimental data. We first validate the method by using synthetic reference data, and subsequently apply the algorithms to data from nuclear magnetic resonance spin-labeling experiments on the Delta 131 Delta fragment of Staphylococcal nuclease. A significant strength of the procedure that we present is that it directly uses experimental data to optimize the energy parameters, without relying on the availability of high resolution structures. The procedure is fully general and can be applied to a range of experimental data and ...

2008-01-01

300

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

301

Episodic Future Thinking Reduces Reward Delay Discounting through an Enhancement of Prefrontal-Mediotemporal Interactions  

British Library Electronic Table of Contents (United Kingdom)

Summary Humans discount the value of future rewards over time. Here we show using functional magnetic resonance imaging (fMRI) and neural coupling analyses that episodic future thinking reduces the rate of delay discounting through a modulation of neural decision-making and episodic future thinking networks. In addition to a standard control condition, real subject-specific episodic event cues were presented during a delay discounting task. Spontaneous episodic imagery during cue processing predicted how much subjects changed their preferences toward more future-minded choice behavior. Neural valuation signals in the anterior cingulate cortex and functional coupling of this region with hippocampus and amygdala predicted the degree to which future thinking modulated individual preference fu...

2010-01-01

302

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

303

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

304

Early diagnosis of skeletal disorders in childhood and adolescence by MRI; Fruehdiagnose orthopaedischer Erkrankungen des Kindes- und Jugendalters mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)

1998-09-18

305

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

306

Characterization of physically vapor deposited AF2400 thin films  

Energy Technology Data Exchange (ETDEWEB)

Anti-reflective coatings made with Teflon AF2400 had the highest damage thresholds recorded for physical vapor deposited coatings at the Lawrence Livermore National Laboratory damage facility. Physical vapor deposited layers of Teflon AF2400, a perfluorinated amorphous polymer, maintained the bulk optical properties of a high transmittance from 200 nm to 1600 nm, and a low refractive index. In addition, the refractive index can be intentionally reduced by control of two common deposition parameters, deposition rate and substrate temperature. Scanning electron microscopy and nuclear magnetic resonance observations indicated that morphological changes caused the variations in the refractive index rather than compositional changes. The coatings adhered to fused silica and silicon wafers under normal laboratory handling conditions.

1993-11-01

307

Brain tumor in childhood. Hjernesvulst hos barn  

Energy Technology Data Exchange (ETDEWEB)

Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.

1990-05-01

308

Biopolymer system for permeability modification in porous media  

Energy Technology Data Exchange (ETDEWEB)

New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were ...

1995-12-31

309

Transmission electron microscopy characterisation of permalloy elements fabricated by focussed ion beam lithography  

International Nuclear Information System (INIS)

20 nm thick permalloy elements, with dimensions of 500 x 500 nm"2 and 1000 x 200 nm"2, have been fabricated on 50 nm thick silicon nitride substrate by milling using a focussed ion beam (FIB) microscope. The dose of ion beam used for the milling was varied in order to achieve the best definition for the milled areas. The FIB milled elements were characterised physically by atomic force microscopy (AFM) and bright field transmission electron microscopy (TEM) and magnetically by Fresnel imaging on a TEM modified for magnetic imaging. The FIB milled elements were found to have a more irregular edge and lower magnetic fields for events such as vortex annihilation when compared to elements of the same dimensions fabricated by conventional electron beam microscopy (EBL).

2006-02-22

310

Cellular interactions of lauric acid and dextran-coated magnetite nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

In vitro cytocompatibility and cellular interactions of lauric acid and dextran-coated magnetite nanoparticles were evaluated with two different cell lines (mouse fibroblast and human cervical carcinoma). Lauric acid-coated magnetite nanoparticles were less cytocompatible than dextran-coated magnetite nanoparticles and cellular uptake of lauric acid-coated magnetic nanoparticles was more than that of dextran-coated magnetite nanoparticles. Lesser cytocompatibility and higher uptake of lauric acid-coated magnetite nanoparticles as compared to dextran-coated magnetic nanoparticles may be due to different cellular interactions by coating material. Thus, coating plays an important role in modulation of biocompatibility and cellular interaction of magnetic nanoparticles.

2007-04-15

311

Cellular interactions of lauric acid and dextran-coated magnetite nanoparticles  

International Nuclear Information System (INIS)

In vitro cytocompatibility and cellular interactions of lauric acid and dextran-coated magnetite nanoparticles were evaluated with two different cell lines (mouse fibroblast and human cervical carcinoma). Lauric acid-coated magnetite nanoparticles were less cytocompatible than dextran-coated magnetite nanoparticles and cellular uptake of lauric acid-coated magnetic nanoparticles was more than that of dextran-coated magnetite nanoparticles. Lesser cytocompatibility and higher uptake of lauric acid-coated magnetite nanoparticles as compared to dextran-coated magnetic nanoparticles may be due to different cellular interactions by coating material. Thus, coating plays an important role in modulation of biocompatibility and cellular interaction of magnetic nanoparticles.

2007-04-01

312

Moderately heavy, heavy-fermion compound YbPd_2Si_2 at low temperatures  

International Nuclear Information System (INIS)

The available experimental data on the specific heat, magnetic susceptibility, magnetization, valence, NMR Knight shift and relaxation rate, and the quadrupolar moment of YbPd_2Si_2 are examined within the framework of the single-ion Anderson model. Such an analysis has previously given excellent agreement between theory and experiment for numerous other light heavy-fermion compounds, where crystalline fields do not play a dominant role. For YbPd_2Si_2, substantial crystalline-field splittings make difficult a quantitative comparison with existing exact solutions of the Anderson model. Inconsistencies with the interpretation that a nearly degenerate ground quadruplet determines the low-temperature thermodynamics are pointed out. It is concluded that at least three of the four Kramers doublets participate in the low-T properties. These three doublets should have a splitting of the order of the Kondo temperature, i.e., about 100 K. A simple ...

313

Moderately heavy, heavy-fermion compound YbPd sub 2 Si sub 2 at low temperatures  

Energy Technology Data Exchange (ETDEWEB)

The available experimental data on the specific heat, magnetic susceptibility, magnetization, valence, NMR Knight shift and relaxation rate, and the quadrupolar moment of YbPd{sub 2}Si{sub 2} are examined within the framework of the single-ion Anderson model. Such an analysis has previously given excellent agreement between theory and experiment for numerous other light heavy-fermion compounds, where crystalline fields do not play a dominant role. For YbPd{sub 2}Si{sub 2}, substantial crystalline-field splittings make difficult a quantitative comparison with existing exact solutions of the Anderson model. Inconsistencies with the interpretation that a nearly degenerate ground quadruplet determines the low-temperature thermodynamics are pointed out. It is concluded that at least three of the four Kramers doublets participate in the low-{ital T} properties. These three doublets should have a splitting of the order of the Kondo temperature, i.e., ...

1992-07-01

314

Evaluation of fetal brain development by magnetic resonance imaging. Subependymal germinal matrix layer and cerebral ventricle  

International Nuclear Information System (INIS)

Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The relation between fetal ages and volume of cerebral ventricle also showed similar pattern. This method will be useful to examine the development of the ...

1999-10-01

315

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that ...

1996-01-01

316

Assembly of Linear Nano-Chains from Iron Oxide Nanospheres with Asymmetric Surface Chemistry  

Science.gov (United States)

Besides the multifunctionality, another equally important aspect of nanoparticles is their engineerability to control the geometrical and chemical properties during fabrication. In this work, we exploited this aspect to define asymmetric surface chemistry of an iron oxide nanosphere by controlling the topology of ligand expression on its surface resulting in a particle with two faces, one displaying only amines and the other only thiols. Specifically, amine-functionalized iron oxide nanospheres were attached on a solid support via a crosslinker containing a disulfide bridge. Liberation of the nanosphere using thiolytic cleavage created thiols on the portion of the particle's surface that interacted with the solid support. Employing a solid-phase strategy and a step-by-step addition of particles, the two unique faces on the same nanosphere served as fittings to assemble them into linear nano-chains. Assembly of chains with various lengths and aspect ratios was controlled by the size and ...

2011-01-06

317

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum control of the radial overlap of the laser/negative ion beam ...

2008-09-01

318

Supersaturation of antiferromagnetically coupled multilayers: A comparative polarised neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

Reflectometric methods like polarised neutron reflectometry (PNR) and synchrotron Moessbauer reflectometry (SMR) are capable of investigating the plane-perpendicular and lateral magnetic structure of multilayers (MLs). Previously, a variety of domain formation and transformation phenomena was found and systematically studied in a Fe/Cr ML of strong antiferromagnetic coupling by PNR and SMR. Growth of the primary domains on passing the bulk-spin-flop transition was established. The domains were found to revert to their native state only in a field considerably higher than the apparent saturation field, a phenomenon referred to as the supersaturation domain memory effect (SDME). We present a comparative PNR study of two antiferromagnetically coupled Fe/Cr MLs with different magnetisation curves. We show that the distribution of the layer-layer coupling rather than the magnetic structure of the Cr spacer layer is responsible ...

2007-07-15

320

Spin Duality on the Neutron (^3He)  

Energy Technology Data Exchange (ETDEWEB)

Thomas Jefferson National Accelerator Facility experiment E01-012 measured the 3He spin structure functions and virtual photon asymmetries in the resonance region in the momentum transfer range 1.0 < Q2 < 4.0 (GeV/c)2. Our date, when compared with existing deep inelastic scattering data, can be used to test quark-hadron duality in g1 and A1 for 3He and the neutron. Preliminary results for A{sub 1}{sup {sup 3}He} are presented, as well as some details about the experiment.

2007-02-01

321

Singlet scalars as Higgs imposters at the Large Hadron Collider  

CERN Document Server

An electroweak singlet scalar can couple to pairs of vector bosons through loop-induced dimension five operators. Compared to a Standard Model Higgs boson, the singlet decay widths in the diphotons and Z gamma channels are generically enhanced, while decays into massive final states like WW and ZZ are kinematically disfavored. The overall event rates into gamma gamma and Z gamma can exceed the Standard Model expectations by orders of magnitude. Such a singlet may appear as a resonant signal in the gamma gamma and Z gamma channels, even with a mass above the WW kinematic threshold.

2011-01-01

322

2D Electrostatic Simulation of the Modulated Electron Beam Interaction with Inhomogeneous Plasma  

International Nuclear Information System (INIS)

Electrostatic plasma simulation code for 2D rectangular geometry is presented. Main distinguishing feature of the code is its orientation on the beam-plasma interaction. The code and its graphical interface were developed using MATLAB programming language. Simulation results of inhomogeneous plasma interaction with modulated electron beams of different width are compared. In case of wide beam the front of Langmuir waves generated in point of local plasma resonance is planar and in case of thin beam (or ribbon beam) the front has approximately half-circular form.

2006-01-01

323

High-temperature ferromagnetism in laser-deposited layers of silicon and germanium doped with manganese or iron impurities  

Energy Technology Data Exchange (ETDEWEB)

The paper reports on the results of a study of the synthesis conditions effects on magnetic and transport properties of nanosized layers of high-T{sub c} diluted magnetic semiconductors (DMS), such as Ge:Mn, Si:Mn and Si:Fe, fabricated by laser-plasma deposition over a wide range of the growth temperature, T{sub g}=(20-550) deg. C on single-crystal GaAs or Al{sub 2}O{sub 3} substrates. Ferromagnetism of the layers was detected by measurement data of the magneto-optical Kerr effect, anomalous Hall effect, negative magnetoresistance and ferromagnetic resonance (FMR) at 5-500 K. The optimum growth temperature, T{sub g}, for Si:Mn/GaAs layers with T{sub c}{approx}400 K is shown to be about 400 deg. C. The Si:Mn/Al{sub 2}O{sub 3} layers with 35% of Mn have the metal-type of conductivity with manifestation of magnetization up to room temperature. Different types of uniformly doped structures and digital ...

2009-04-15

326

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal ...

1999-10-01

327

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...

2003-03-01

328

Quantum molecular dynamics and molecular interactions studied by NMR and INS[Nuclear magnetic resonance; Proton tunnelling; Hydrogen bond  

Energy Technology Data Exchange (ETDEWEB)

The wavefunction of a particle extends into the classically forbidden barrier region of the potential energy surface. The consequence of this partial delocalisation is the phenomenon of quantum tunnelling, an effect which enables a particle to penetrate a potential barrier of magnitude greater than the energy of the particle. The tunnelling probability is an exponential function of the particle mass. The effect is therefore an important contribution to the behaviour of light atoms, in particular the proton. The hydrogen bond has long been appreciated to be an essential component of many biological and chemical systems, and the proton transfer reaction in the hydrogen bond is fundamental to many of these processes. The proton behaviour in the hydrogen bonds of benzoic acid, acetylacetone and calix-4-arene has been studied. A variety of techniques, both experimental and computational, were adopted for the study of the three hydrogen bonded systems. The complementary spectroscopic ...

2002-07-01

329

Nuclear magnetic resonance spectroscopy in biomedicine. Course organized by the Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), September 18-23, 1995; Spettroscopia di risonanza magnetica nucleare in biomedicina. Corso organizzato dall`Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), 18-23 settembre 1995  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di condizioni imposto dalla ...

1997-12-01

330

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with transient ischemic attacks (TIA) and the ...

1997-05-01

331

Hilar cholangiocarcinoma: MR correlation with surgical and histological findings  

International Nuclear Information System (INIS)

Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the ...

2010-10-01

332

Functional magnetic resonance imaging of the normal and abnormal visual system in early life.  

DEFF Research Database (Denmark)

Functional magnetic resonance imaging (fMRI) in young children may provide information about the development of the visual cortex, and may have predictive value for later visual performance. The purpose of this study was to evaluate the usefulness of fMRI for examining cerebral processing of vision in very young infants and in infants with brain damage. We examined 15 preterm infants, 12 children suspected of having a cerebral visual impairment and 10 children with a normal visual system, all of whom were either spontaneously asleep or sedated with chloral hydrate. Cortical response to stroboscopic light stimulation could be demonstrated in all technically acceptable data sets from children with a post-menstrual age (PMA) of > 41 weeks, but not in younger infants. Children < 60 weeks PMA showed either a blood oxygenation level-dependent (BOLD) signal increase or decrease, while all older children showed a signal decrease. The activated ...

2000-01-01

333

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have ...

2008-04-15

334

Detection of Cholangiocarcinoma with Magnetic Resonance Spectroscopy of Bile in Patients with and without Primary Sclerosing Cholangitis  

International Nuclear Information System (INIS)

Background: Early detection of cholangiocarcinoma (CC) is very difficult, especially in patients with primary sclerosing cholangitis (PSC) who are at increased risk of developing CC. Purpose: To evaluate "1H magnetic resonance spectroscopy ("1H-MRS) of bile as a diagnostic marker for CC in patients with and without PSC. Material and Methods: The institutional review board approved the study, and all patients gave informed consent. Bile from 49 patients was sampled and investigated using "1H-MRS. MR spectra of bile samples from 45 patients (18 female; age range 22-87 years, mean age 57 years) were analyzed both conventionally and using computerized multivariate analysis. Sixteen of the patients had CC, 18 had PSC, and 11 had other benign findings. Results: The spectra of bile from CC patients differed from the benign group in the levels of phosphatidylcholine, bile acids, lipid, and cholesterol. It was possible to distinguish CC from benign ...

2008-10-01

335

Characterization of Absolute-Resonant Eddy Current Probes,  

Science.gov (United States)

... Accession Number : ADD335809. Title : Characterization of Absolute-Resonant Eddy Current Probes,. Corporate Author : ...

336

Electromagnetic structure of decuplet baryons towards the chiral regime  

Science.gov (United States)

The electromagnetic properties of the baryon decuplet are calculated in quenched QCD on a 20{sup 3}x40 lattice with a lattice spacing of 0.128 fm using the fat-link irrelevant clover fermion action with quark masses providing a pion mass as low as 300 MeV. Magnetic moments and charge radii are extracted from the electric and magnetic form factors for each individual quark sector. From these, the corresponding baryon properties are constructed. We present results for the higher-order moments of the spin-3/2 baryons, including the electric-quadrupole moment E2 and the magnetic-octupole moment M3. The world's first determination of a nonzero M3 form factor for the {delta} baryon is presented. With these results we provide a conclusive analysis which shows that decuplet baryons are deformed. We compare the decuplet-baryon results from a similar lattice calculation of the octet baryons. We establish ...

2009-09-01

337

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub ...

2000-05-01

338

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

339

Magnetic liquefier for hydrogen  

Energy Technology Data Exchange (ETDEWEB)

This document summarizes work done at the Astronautics Technology Center of the Astronautics Corporation of America (ACA) in Phase 1 of a four phase program leading to the development of a magnetic liquefier for hydrogen. The project involves the design, fabrication, installation, and operation of a hydrogen liquefier providing significantly reduced capital and operating costs, compared to present liquefiers. To achieve this goal, magnetic refrigeration, a recently developed, highly efficient refrigeration technology, will be used for the liquefaction process. Phase 1 project tasks included liquefier conceptual design and analysis, preliminary design of promising configurations, design selection, and detailed design of the selected design. Fabrication drawings and vendor specifications for the selected design were completed during detailed design. The design of a subscale, demonstration magnetic ...

1992-12-31

340

Magnetic field-induced currents in the human body in proximity of power lines  

Energy Technology Data Exchange (ETDEWEB)

Electric currents induced due to 60 Hz magnetic fields in a human body placed in a close proximity of various high voltage transmission lines are computed. A realistic model of the human body from the anatomical and electrical point of view with resolution of 1.3 cm for the body and 0.665 cm for the head is used. The computations are performed using the impedance method. Three representative configurations of high voltage transmission lines, namely 500 kV, 138 kV and 25 kV are analyzed. The results indicate that the maximum current densities of the order of 0.2 {micro}A/cm{sup 2} can be induced in a lineman working on a 500 kV line (0.5 m away from closest conductors). A good correlation can be seen between the computed magnetic field in the location of the human body and the induced current densities. The induced currents computed here and estimated from measured magnetic fields in various power line environments are ...

1996-01-01

341

Suppression of the transverse scattering amplitude in /sup 207/Pb  

Energy Technology Data Exchange (ETDEWEB)

Transverse form factors have been extracted for the low-lying neutron hole (particle) states of /sup 207/Pb from inelastic-electron-scattering data. A systematic, multipolarity-and momentum-transfer-independent quenching of approx.55% in the transverse amplitude is observed when compared with single particle predictions for both electric and magnetic transitions. The magnitude of the observed effect is not readily explained by our present theoretical understanding of this nucleus.

1980-07-14

342

Loss of light charged particles by nuclear interactions in BaF[sub 2] crystals  

Energy Technology Data Exchange (ETDEWEB)

The nuclear interaction probability of light charged particles in BaF[sub 2] crystals has been studied as a function of the incident particle energy. Light charged particles were identified in charge and mass by measuring their magnetic rigidity and their time-of-flight. The percentage of particles undergoing nuclear interactions has been measured for particles of charge from Z=1 to Z=6 and the experimental data are compared with the results of a model calculation. (orig.)

1993-07-15

343

Investigation of lifetimes in the dipole band of {sup 139}Sm  

Energy Technology Data Exchange (ETDEWEB)

Lifetimes have been measured for a dipole band in {sup 139}Sm using DSAM. The deduced B(M1) and B(E2) values as well as B(M1)/B(E2) ratios are compared with calculations in the framework of the TAC (Tilted Axis Cranking) and SPAC (Shears mechanism with Principal Axis Cranking) models. The dipole band in {sup 139}Sm can be considered as a magnetic rotational band with a prolate or triaxial nuclear deformation. (orig.)

2008-09-15

344

Investigation of lifetimes in dipole bands of {sup 142}Gd  

Energy Technology Data Exchange (ETDEWEB)

Lifetimes have been measured for dipole bands in {sup 142}Gd using DSAM. The deduced B(M1) and B(E2) values as well as B(M1)/B(E2) ratios are compared with calculations in the framework of the TAC (Tilted Axis Cranking) and SPAC (shears mechanism with Principal Axis Cranking) models. The dipole bands DB1 to DB4 can be interpreted as magnetic rotational bands. (orig.)

2005-02-01

345

Transformation of the ATOMKI-ECRIS into a Plasma Device  

International Nuclear Information System (INIS)

Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check the components and charge-state of the plasma. A new, large, but ...

2006-01-01

346

Intracellular monitoring of superoxide dismutase expression in an Escherichia coli fed-batch cultivation using on-line disruption with at-line surface plasmon resonance detection.  

Science.gov (United States)

An on-line cell disruption system for at-line monitoring of the intracellular concentration of recombinant human superoxide dismutase (rhSOD) in a genetically modified Escherichia coli strain, HMS174(DE3) (pET11a/rhSOD), in bioreactor cultivations is described. The sampled bacteria were disrupted on-line by rapid mixing with a nonionic detergent. The recombinant protein content of the lysed bacterial sample was quantitated by a subsequent surface plasmon resonance biosensor with a specific monoclonal antibody. Extraction efficiency of the monitoring system was optimized with respect to the flow rate ratio of the cell suspension and the detergent at relevant cell densities with the aim to attain rapid monitoring. Monitoring was demonstrated for a shake flask culture and a glucose-limited fed-batch cultivation. The results are compared with a traditional enzyme-linked immunosorbent assay method showing a correlation coefficient of R2 = 0.97. ...

2005-07-01

347

Benchmarking of epithermal methods in the lattice-physics code EPRI-CELL  

International Nuclear Information System (INIS)

The epithermal cross section shielding methods used in the lattice physics code EPRI-CELL (E-C) have been extensively studied to determine its major approximations and to examine the sensitivity of computed results to these approximations. The study has resulted in several improvements in the original methodology. These include: treatment of the external moderator source with intermediate resonance (IR) theory, development of a new Dancoff factor expression to account for clad interactions, development of a new method for treating resonance interference, and application of a generalized least squares method to compute best-estimate values for the Bell factor and group-dependent IR parameters. The modified E-C code with its new ENDF/B-V cross section library is tested for several numerical benchmark problems. Integral parameters computed by EC are compared with those obtained with point-cross section Monte Carlo ...

2008-09-21

348

Acidic and neutral polar NSO compounds in Smackover oils of different thermal maturity revealed by electrospray high field Fourier transform ion cyclotron resonance mass spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Negative ion electrospray ionization (ESI) coupled with high field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) allows for the direct detection of acidic NSO compounds in petroleum. The technique requires no chromatographic separation, is able to distinguish 18 different compound classes (e.g., neutral nitrogen, carboxylic acids and oxygenates), and can identify {approx}14,000 distinct masses by ultra-high mass resolution and mass accuracy. We previously studied three crude oils from different geological origins [Organic Geochemistry 33 (2002b) 743-759]. Here, we expand our research by comparing two source-equivalent Smackover oils of different levels of thermal maturity. We observe clear differences in the distribution of NSO compound classes, types (number of rings plus double bonds within a class), and number of alkyl carbons. With increasing thermal stress, the relative amount of sulfur and oxygen containing ...

2004-07-01

349

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

350

Role of core toroidal rotation on the H-mode radial electric field shear, turbulence, and confinement as studied by magnetic braking in the DIII-D tokamak  

International Nuclear Information System (INIS)

''Magnetic braking'' of the plasma toroidal rotation in the high confinement H mode by applied resonant, low m,n=1 static error fields is used in DIII-D [Nucl. Fusion 31, 875 (1991)] as an independent control to evaluate the E_rxB stabilization of microturbulence in the plasma core. In the core (#rho# approx-lt 0.9) of a tokamak, the radial electric field and its shear are dominated by toroidal rotation. The fundamental quantity for shear stabilization of microturbulence is shear in the velocity of the fluctuations v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#E_rxB/B#centre dot#B which in the core is v_p_e_r_p_e_n_d_i_c_u_l_a_r#approx#v_#phi#B_#theta#/ B_#phi#. With magnetic braking greatly decreasing the toroidal rotation and thus reducing the core radial electric field and shear, far infrared (FIR) measurements of density microturbulence show downshifting in frequency near #rho##approx#0.8 as a result of the reduced Doppler shift ...

351

Continuum damping of toroidal Alfven eigenmodes in finite-#beta# tokamak equilibria  

International Nuclear Information System (INIS)

A general theoretical approach for the study of the two-dimensional structure of high-n Toroidal Alfven Eigenmodes (TAE) in finite-#beta#, large aspect ratio (R_o/a much-gt 1) tokamak equilibria is presented. Here, n is the toroidal mode number, #beta# = plasma/magnetic pressure, and a(R_o) is the minor (major) radius of the torus. It is shown how the general pseudo-differential boundary value problem for the radial eigenmode structure can be systematically constructed from the local dispersion relation; which is obtained using the ballooning formalism. The TAE modes are characterized by a broad radial envelope, the width of which is independent on the mode number in the general case of monotonic equilibrium profiles. The results on the two-dimensional eigenmode structure are expected to be applicable to drift-type waves. The ballooning transform is generalized here to handle singular eigenfunctions typical of the continuous shear Alfven spectrum, and, thereby, ...

352

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were ...

2011-09-01

353

TIME EVOLUTION OF CORONAL MAGNETIC HELICITY IN THE FLARING ACTIVE REGION NOAA 10930  

International Nuclear Information System (INIS)

To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through ...

2010-09-10

354

Synthesis of colloidal silver iron oxide nanoparticles--study of their optical and magnetic behavior.  

Science.gov (United States)

Silver iron oxide nanoparticles of fairly small size (average diameter approximately 1 nm) with narrow size distribution have been synthesized by the interaction of colloidal beta- Fe2O3 and silver nanoparticles. The surface morphology and size of these particles have been analyzed by using atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Their structural analysis has been carried out by employing x-ray diffraction (XRD), selected-area electron diffraction (SAED), optical and infrared (IR) spectroscopic techniques. The ageing of these particles exhibits the formation of self-assembly, possibly involving weak supramolecular interactions between Ag(I)O4 and Fe(III)O4 species. These particles display the onset of absorption in the near-infrared region and have higher absorption coefficient in the visible range compared to that of its precursors. Magnetic measurements ...

2009-07-01

355

Structure and magnetic properties of nanostructural strontium ferrite prepared by mechanochemical treatment  

International Nuclear Information System (INIS)

Full text: It was recently-established for hexagonal barium ferrite-industrially important magnetically hard material that refinement of the crystallite dimensions into the nanoscale regime, typically #<=# 10 nm, leads after heat treatment at temperatures 800-1000 deg C to significant coercivity increase of up to 6.5 kOe (#approx#3-4 times) with saturation magnetisation values of 50-55 emu/g (#approx#95% of bulk at room temperature). High-energy mechanochemical processing has been applied to prepare nanostructural (nanocrystalline-amorphous) composites. High resolution electron microscopy studies reveal that the enhancement of the final magnetic properties was due to formation of magnetically noninteracting #approx#l,#mu#m Ba-ferrite particles with 5-10 nm amorphous surface layer - depending on annealing parameters. Similar situation was established also for ball milled strontium ferrite (SrFe_1_2O_1_9) powders where ...

356

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

358

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

359

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

360

Modelling and design of smoothing reactances. Application to air gap length calculation  

Energy Technology Data Exchange (ETDEWEB)

A new method for analysis and design of smoothing reactances utilising two-dimensional planar models is presented in this paper. Inductance and magnetic flux density are calculated, and their results compared with those measured experimentally. The results obtained are good if compared with those measured once the machine have been built. Moreover, the method herein developed is applied to the calculation of air gap lengths in terms of the desired current and inductance. The kind of reactances studied presents windings in both limbs and air gaps in the four corners (joint of limbs and yokes). The main contribution of this paper is the presentation of a method of industrial application, to be easily developed, with a very important reduction in the time of machine calculation (due to the decrease in the number of nodes and elements compared with the three-dimensional model) for the determination of the ...

2000-08-01

361

Unsteady MHD micro polar flow and heat transfer over a vertical porous moving plate with variable suction  

Energy Technology Data Exchange (ETDEWEB)

The unsteady two-dimensional laminar flow of a viscous incompressible electrically conducting micro polar fluid via a porous medium past a semi-infinite vertical porous moving plate in the presence of a transverse magnetic field is studied. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micro polar fluid with a suction velocity varying with time. The effects of material parameters on the velocity and temperature fields across the boundary layer are investigated. The method of solution can be applied for small perturbation approximation. Numerical results of velocity and temperature distributions of micro polar fluids are compared with the corresponding flow problems for a Newtonian fluid. (author)

2001-07-01

362

Synthesis and characterization of Fe3O4Gg nanocomposites and their antibacterial performance  

British Library Electronic Table of Contents (United Kingdom)

We synthesized Fe3O4Gg nanocomposites through a combination of solvothermal, hydrothermal, and chemical redox reactions. Characterization of the resulting samples by X-ray diffraction, Fourier-transform infrared spectroscopy, field-emission scanning and transmission electron microscopy, and magnetic measurement is reported. Compared to Fe3O4g nanocomposites, the Fe3O4Gg nanocomposites showed enhanced antibacterial activity. The Fe3O4Gg nanocomposites were able to almost entirely prevent growth of Escherichia coli when the concentration of Ag nanoparticles was 10mg/mL. Antibacterial activity of the Fe3O4Gg nanocomposites was maintained for more than 40h at 37^oC. The intermediate carbon layer not only protects magnetic core, but also improves the dispersion and antibacterial activity of the...

2011-01-01

363

Starting characteristics of direct current motors powered by solar cells  

Energy Technology Data Exchange (ETDEWEB)

Direct current motors are used in photovoltaic systems. Important characteristics of electric motors are the starting to rated current and the torque ratios. These ratios are dictated by the size of the solar cell array and are different for the various dc motor types. The paper deals with the calculation of the starting to rated current ratio and starting to rated torque ratio of the permanent magnet, separately, series and shunt excited motors when powered by solar cells for the two cases: where (1) the system includes a maximum-power-point-tracker (MPPT) and (2) without an MPPT. Comparing these two cases, one gets a torque magnification of about 3 for the permanent magnet motor and about 7 for other motor types at rated design insolation. The calculation of the torques may assist the PV system designer to determine the advantage of including an MPPT in the system as far as the starting characteristics of the dc motors ...

1993-03-01

364

Saturation of relativistic Weibel instability and the formation of stationary current sheets in collisionless plasma  

International Nuclear Information System (INIS)

We have studied the features of formation and the possible stationary structures of a self-consistent magnetic field in a relativistic collisionless plasma, which are characteristic of a simple geometry of the Weibel instability that is well known in the nonrelativistic case. The universal condition is established, the growth rate is determined, and the criteria of saturation of the Weibel instability are analyzed for a broad class of anisotropic particle distribution functions (for definiteness, in application to an electron-positron plasma). A nonlinear equation of the Grad-Shafranov type describing the potential current structures is derived and its solutions are analytically studied. Special attention is paid to spatially harmonic, nonlinear current configurations with parameters determined by the properties of the initial homogeneous plasma subject to the Weibel instability. It is demonstrated that the magnetic field energy density in the ...

2008-12-01

365

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

366

Magnetic properties and magnetic ordering in the rare earth molybdenum(IV) pyrochlores: R_2Mo_2O_7  

International Nuclear Information System (INIS)

The series of cubic pyrochlore structure compounds, R_2Mo_2O_7 (R = Nd-Yb, Y; R not= Eu), were prepared as single phase materials by solid state reaction between R_2O_3 and MoO_2 at 1400 "0C in a CO/CO_2 = 1 buffer gas atmosphere. Lattice constants obtained from X-ray powder data compare well with results from previous studies. Magnetic susceptibility and magnetization data were obtained for all samples between 300 K and 4.2 K (700 K for R = Gd) and a range of applied fields. For R = Nd, Sm, and Gd magnetic ordering is observed at 97 K, 93 K and 83 K respectively which is assigned to ferromagnetism on the Mo(IV) sublattice. The Mo(IV) moment in the ordered state is about 1 #mu#/sub B/. At low temperatures, the Gd(III) and Mo(IV) moments are apparently coupled feromagnetically in Gd_2Mo_2O_7 yet the high temperature susceptibility data seem to indicate a ferrimagnetic (antiparallel) Gd(III)-Mo(IV) ...

1986-01-01

367

Longitudinal impedance and wake from XFEL undulators. Impact on current-enhanced SASE schemes  

Energy Technology Data Exchange (ETDEWEB)

In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuumchamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to derive an analytical solution for a Gaussian transverse and longitudinal bunch shape. Finally, we study the feasibility of ...

2007-06-15

368

Longitudinal impedance and wake from XFEL undulators. Impact on current-enhanced SASE schemes  

International Nuclear Information System (INIS)

In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to derive an analytical solution for a Gaussian transverse and longitudinal bunch shape. Finally, we study the feasibility ...

2007-12-21

369

Longitudinal impedance and wake from XFEL undulators. Impact on current-enhanced SASE schemes  

CERN Document Server

In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region of interest for practical applications. We calculate a closed expression for impedance and wake function that may be evaluated numerically in the most general case. Such expression allows us to derive an analytical solution for a Gaussian transverse and longitudinal bunch shape. Finally, we study the feasibility ...

2007-01-01

370

Visualization and volumetric structures from MR images of the brain  

Energy Technology Data Exchange (ETDEWEB)

Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet ...

1994-03-01

371

Thermodynamic and kinetic aspects of surface acidity  

Science.gov (United States)

Our research in the general area of acid catalysis involves the characterization of solid acidity and the corresponding assessment of catalytic performance of acidic materials. Acid characterization studies are required to provide essential information about the type of acid site (i.e., Lewis versus Bronsted), the strength of the sites, and the mobility of molecules adsorbed on the acid sites. An accurate measure of acid strength is given by the heat of adsorption of a basic probe molecule on the acid site. A thermodynamic representation of the mobility of adsorbed species on these sites is given by the entropy of adsorption. Important techniques used in these acid site characterization studies include microcalorimetry, thermogravimetric measurements, temperature programmed desorption, infrared spectroscopy and solid state nuclear magnetic resonance. The combination of these acid site characterization studies with reaction kinetics measurements ...

1992-01-01

372

Surgery for acoustic neurinoma treated by gamma-knife radiosurgery. A case report  

Energy Technology Data Exchange (ETDEWEB)

A 52-year-old woman had a history of left hearing loss for 5 years. An acoustic neurinoma with 3.2 cm in diameter was diagnosed and treated with gamma-knife radiosurgery (19 Gy of marginal dose) 1 year and 4 months ago. She developed headache, nausea, and visual disturbance 1 month prior to admission. Slight left facial palsy appeared after radiosurgery. Magnetic resonance imaging demonstrated the tumor with central necrosis in the left cerebellopontine angle cistern, increasing in size to 3.5 cm in diameter, and hydrocephalus. Tumor removal was performed incompletely, because of the fibrous appearance of the tumor and severe adherence with the surrounding cerebellar tissue. Facial palsy did not worsen after surgery. Since the hydrocephalus was not resolved, a right ventriculo-peritoneal shunt was inserted. The clinical course in this case suggests that tumor removal followed by radiosurgery was an approximately effective treatment for large ...

2001-08-01

373

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li{sub 2}S-SiS{sub 2}-Li{sub 3}PO{sub 4} Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li{sub 2}S{center_dot}0.4SiS{sub 2})centre dotxLi{sub 3}PO{sub 4} oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO{sub n}S{sub 4-n} (n=1,2,3) and PO{sub n}S{sub 4-n} (n=1,2,3) present in the glass samples vanished and the SiS{sub 4}, PS{sub 4}, SiO{sub 4} units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S{sup 2-} increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

374

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li[sub 2]S-SiS[sub 2]-Li[sub 3]PO[sub 4] Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li[sub 2]S[center dot]0.4SiS[sub 2])centre dotxLi[sub 3]PO[sub 4] oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO[sub n]S[sub 4-n] (n=1,2,3) and PO[sub n]S[sub 4-n] (n=1,2,3) present in the glass samples vanished and the SiS[sub 4], PS[sub 4], SiO[sub 4] units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S[sup 2-] increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

375

Sorption equilibrium and hydration studies of lysozyme: water activity and 360-MHz proton NMR measurement  

International Nuclear Information System (INIS)

An attempt to determine lysozyme hydration by employing a proton nuclear magnetic resonance (NMR) spin-echo technique and to correlated such measurements with the 20 "0C sorption equilibrium data is made. Determinations of specific site hydration for lysozyme, as well as proton NMR transverse relaxation rates for five different types of water populations in the lysozyme-water system, are presented over the whole range of lysozyme concentrations. The proton spin-echo NMR results are consistent with a three-component analysis of the sorption isotherm up to 70% water content, above which two additional water populations are identified by 360-MHz proton NMR spin-echoes. On the basis of the proton NMR results, a major component (III) of the lysozyme sorption isotherm is assigned to the water trapped between lysozyem molecules, whose relaxation rate is increased by diffusion barriers. The trapped water population dominates the relationship between ...

376

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After surgical treatment, the ...

377

Soft tissue manifestations of early rheumatic disease. Imaging with MRI  

International Nuclear Information System (INIS)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a ...

2006-08-01

378

Potential anti fungal agents. Synthesis and activity of 2-alkylthiopyridine-4-carbothioamides  

Energy Technology Data Exchange (ETDEWEB)

A series of 2-alkylthiopyrine-4-carbothioamides were synthesized, and their anti-fungal potency was tested. The chemical structures were proved by infrared spectroscopy (IR) and {sup 1}H nuclear magnetic resonance ({sup 1}H-NMR) data and by elemental analysis. The minimal inhibitory concentration (MIC) and minimal fungicidal concentration (MFC) assessment were used for the estimation of potential activity in vitro. The study comprising 21 clinical isolates of fungi showed that two compounds exhibited fair inhibitory activity against some yeasts and dermatophytes. Selective fungistatic activity against non-dermatophytes (MIC = 3.12-25.0 {mu}g/mL) was found also in another compound. None of the above compounds showed inhibitory activity against non-dermatophyte filamentous fungi. Microbiological activity of 2-alkylthiopyridine-4-carbothioamides appears to be mainly related to hydrophobicity of alkyl in position 2. (authors). 10 refs., 8 tabs.

1996-05-01

379

Novel non-discoid chiral copper(II)-salen type [N2O2] donor Schiff base complexes with a cyclohexane diamine spacer: synthesis, electrochemistry, columnar mesomorphism and DFT study  

British Library Electronic Table of Contents (United Kingdom)

A series of new non-discoid chiral copper(ii)-salen type complexes, [Cu((4-CnH2n+1O)2salen)], n = 14, 16, 18 and salen = N,N'-cyclohexane bis (salicylideneiminato), containing 4-substituted alkoxy tails in the side aromatic rings and a cyclohexane spacer, have been prepared and their mesogenic properties investigated. The compounds were characterised by Fourier transform infra-red spectroscopy, 1H and 13C nuclear magnetic resonance spectroscopy, UV-vis spectroscopy and fast atom bombardment mass spectrometry. Mesomorphic properties of these compounds were studied by polarising optical microscopy, differential scanning calorimetry and X-ray diffraction (XRD). The ligands are non-mesogenic but the complexes exhibited enantiotropic rectangular columnar mesophases (Colr) with extended temperat...

2011-01-01

380

Normal and abnormal water diffusion in the brain  

International Nuclear Information System (INIS)

Diffusion magnetic resonance imaging (MRI) has become an important tool in the radiologic diagnosis of diseases of the brain as it measures molecular motion of water that characterizes the microstructure of tissues. Its most important clinical use to date is the early detection of cerebral ischemia by revealing the ischemic injury shortly after vessel occlusion and simultaneously providing therapy-relevant information on the tissue at risk. Furthermore, diffusion MRI is diagnostically promising in other diseases of the brain and is thus increasingly becoming part of routine clinical protocols in the diagnosis of tumors, inflammation, trauma, demyelination, dysmyelination and neurodegeneration. Although abnormalities of diffusion are generally not pathognomonic, diffusion MRI affords information about tissue changes for specific disorders that complements information obtained with standard MR techniques and frequently shows pathology earlier. In ...

2003-10-01

381

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D ...

2008-04-15

382

Mechanism of adenylate kinase. Dose adenosine 5'-triphosphate bind to the adenosine 5'-monophosphate site  

Energy Technology Data Exchange (ETDEWEB)

Although the subtrate binding properties of adenylate kinase (AK) have been studied extensively by various biochemical and biophysical techniques, it remains controversial whether uncomplexed adenosine 5'-triphosphate (ATP) binds to the adenosine 5'-monophosphate (AMP) site of AK. The authors present two sets of experiments which argue against binding of ATP to the AMP site. (a) /sup 31/P nuclear magnetic resonance titration of ATP with AK indicated a 1:1 stoichiometry on the basis of changes in coupling constants and line widths. This ruled out binding of ATP to both sites. (b) ATP and MgATP were found to behave similarly by protecting AK from spontaneous inactivation while AMP showed only a small degree of protection. Such inactivation could also be protected or reversed by dithioerythritol and is most likely due to oxidation of sulfhydryl groups, one of which (cysteine-25) is located near the MgATP site. The results support ...

1987-10-06

383

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der Darstellung der Meningitis beobachtet. Eine ...

1994-12-31

384

MRS of normal and impaired fetal brain development  

International Nuclear Information System (INIS)

Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are ...

2006-02-01

385

Longitudinal and transverse dynamics of a free electron laser based on a storage ring of second and third generation  

International Nuclear Information System (INIS)

This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a modulation, the FEL can present a periodic or chaotic regime. The ...

386

Light liquid hydrocarbons from the catalytic pyrolysis of sewage sludge lipid  

Energy Technology Data Exchange (ETDEWEB)

The lipid obtained by the toluene extraction of a dried raw Atlanta sewage sludge by the Soxhlet method, was pyrolyzed over activated alumina at atmospheric pressure. A range of weight hourly space velocities (WHSV) from 0.22-1.60/h and a range of temperatures from 400-480[degree]C were selected. A 70 wt % yield of light liquid hydrocarbons was obtained at a WHSV of 0.46/h and 450[degree]C. The sulfur and nitrogen contents of the pyrolysis products were much lower than products from direct liquefaction of sludge. Infrared spectra and [sup 13]C nuclear magnetic resonance confirmed the absence of carbonyl groups in the products. Gas chromatography showed a uniform hydrocarbon chain length distribution across the C[sub 7] to C[sub 17] mass range. The gas product consisted mainly of carbon dioxide and hydrocarbons. Lauric acid was used as a model to study the decarboxylation. The effects of catalyst loading and catalyst moisture content were ...

1993-01-01

387

Kinetic studies of preactivated derivatives of cyclophosphamide by "3"1P NMR spectroscopy  

International Nuclear Information System (INIS)

Selected derivatives of cyclophosphamide (CP) metabolites were synthesized and the solution chemistry of each was studied by "3"1P nuclear magnetic resonance (NMR) spectroscopy under a standard set of reaction conditions at physiological pH (7.4) and temperature (37"0C). Complementary "2H and "1"3C NMR spectral data was obtained using isotopically ("2G and "1"3C) enriched CP metabolites. The CP derivatives were synthesized by the ozonolysis of substituted 3-butenyl phosphorodiamidates, and were isolated as analogues of either cis and trans 4-hydroperoxy-CP or aldophosphamide (AP). The relative ratios of the tautomeric species, 4-hydroxy-CP and AP, and their half-lives (T/sub 1/2/) were measured by "3"1P NMR spectroscopy. The influence of CP metabolites on perfused U-937 cells, a CP-sensitive human lymphoma, was observed by high resolution "3"1P NMR spectroscopy. In this manner, it was possible to measure, for the first time, a rate constant for ...

388

Interaction of cis-diamminediaquoplatinum(II) with adenosylcobalamin and alkylcobalamins  

Energy Technology Data Exchange (ETDEWEB)

The interaction of cis-diamminediaquoplatinum(II) nitrate with adenosylcobalamin and a series of alkylcobalamins was studied by carbon-13 nuclear magnetic resonance spectroscopy and by electronic spectroscopy. With these cobalamins cis-(Pt(NH/sub 3/)/sub 2/(OH/sub 2/)/sub 2/)/sup 2 +/ forms adducts in which N(3) of the 5,6-methylbenzimidazole moiety is co-ordinated to platinum(II) rather than to cobalt(III) of the corrin. The chemical shifts of the 5'-methylene carbon of adenosylcobalamin-platinum adduct and of the Co-methyl carbon of the methylcobalamin-platinum adduct are characteristic of these cobalamins in the base-off form. Furthermore, these cobalamin-platinum complexes have visible spectra identical to those of the cobalamins in acidic solution. The /sup 13/C NMR spectrum of the adenosylcobalamin-platinum complex suggests the presence of a second adduct in which platinum(II) complexes are co-ordinated to both the N(3) of the ...

1980-01-01

389

In vivo phosphorylation of histones H1 and H5 in calf thymus and chicken erythrocytes as studied by /sup 31/P nuclear magnetic resonance spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The /sup 31/P NMR method was first applied to characterize in vivo phosphorylation of H1 and H5 in calf thymus and chicken erythrocytes as well as in vitro phosphorylation of H1 and H5 by cAMP-dependent protein kinase. The amino acid residues phosphorylated in vivo in the histones were exclusively serine residues, and the mole fraction of phosphoserine was estimated to be 0.34 and 0.27 per molecule of calf thymus H1 and chicken erythrocyte H5, respectively. Interestingly, chicken erythrocyte H1 was not phosphorylated in vivo. Three H1 subtypes from calf thymus H1 varied in the /sup 31/P NMR spectra, and the bisected fragments of calf thymus H1 and chicken erythrocyte H5 exhibited characteristic spectral patterns, indicating that there are considerable diversities of the degree of phosphorylation and phosphorylation sites in very-lysine-rich histones. Furthermore, it was found that the microenvironment of phosphoserine residues phosphorylated in vivo in calf thymus H1 and chicken ...

1987-08-01

390

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium ...

1998-06-01

391

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences  

International Nuclear Information System (INIS)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of ...

392

Enzymatic synthesis and carbon-13 nuclear magnetic resonance conformational studies of disaccharides containing #beta#-D-galactopyranosyl and #beta#-D-[1-"1"3C]Galactopyranosyl residues  

International Nuclear Information System (INIS)

Partially purified UDPgalactosyltransferase (EC 2.4.1.22) from bovine milk has been used to synthesize millimolar amounts of compounds such as Gal#beta#(1#->#4)Glc, Gal#beta#(1#->#4)GlcNAc-#beta#-hexanolamine, and Gal#beta#(1#->#4)-GlcNAc#beta#(1#->#4)GlcNAc. The same method has been used to prepare similar compounds containing "1"3C-enriched galactopyranosyl moieties. Gal#beta#(1#->#4)GlcNAc-#beta#-hexanolamine was also synthesized in a solid-phase system in which the GlcNAc-#beta#-hexanolamine glycoside was covalently linked to agarose beads. At pH 7.0 and at 1 to 5 mM Mn"2"+"+ the yields of the galactosyl saccharides are greater than 90% by using 10% excess of UDPGal donor. The use of a 90% enriched [1-"1"3C]galactosyl residue allowed the determination of the most abundant conformer about the galactopyranosyl-glycoside linkage by analysis of the carbon-carbon coupling constants from Cl to Gal to the C3', C4', and C5' of GlcNAc or Glc. 3 figures, 1 table.

393

Early effects of boron neutron capture therapy on rat glioma models  

International Nuclear Information System (INIS)

Early effects of boron neutron capture therapy (BNCT) on malignant glioma are characterized by reduction of the enhancement area and regression of the peritumoral edema radiologically. The aim of this study was to investigate the early histological changes of tumors and inflammatory cells after BNCT in the rat brain. Rats were treated with BNCT using boronophenylalanine (BPA) 7 days after implantation of C6 glioma cells. The tumors were assessed with magnetic resonance imaging and histopathological examination at 4 days after BNCT. The mean tumor volumes were 39#+-#2 mm"3 in the BNCT group and 134#+-#18 mm"3 in the control group. In the BNCT group, tumor cells showed a less pleomorphic appearance with atypical nuclei and mitotic figures. The Ki-67 labeling index was 6.5%#+-#4.7% in the BNCT and 35%#+-#3.8% in the control group. The reactions of the inflammatory cells were examined with ED-1 as macrophage marker and OX42 as microglia marker. ...

394

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...

395

Diagnostic difficulties in extraosseous Ewing's sarcoma: A proposal for diagnostic criteria  

International Nuclear Information System (INIS)

Five cases diagnosed as extraosseous Ewing's sarcoma (EES) during a 15 year period, and the relevant literature, were reviewed. The diagnosis in these cases was difficult to confirm, mainly because the distinction between the osseous form of Ewing's sarcoma (OES) and either periosteal reactions or direct tumour invasion into adjacent bone by EES was often unclear. The literature suggests that other authors have also encountered difficulties. The authors believe that many cases reported as EES are likely to have been OES. This distinction has some importance, as the two conditions are usually treated in differing ways. The following criteria are proposed for the diagnosis of primary EES: (i) no evidence of bony involvement on magnetic resonance imaging; (ii) no evidence of increased uptake in bone or periosteum adjacent to the tumour on static isotope bone scan images; (iii) a small round cell tumour with no differentiating features on light ...

396

Crystal growth, structural and optical characterization of a semi-organic single crystal for frequency conversion applications  

International Nuclear Information System (INIS)

Single crystals of semi-organic L-histidine hydrobromide have been grown by slow evaporation technique from a mixture of L-histidine and hydrobromic acid in aqueous solution at ambient temperature. From high-resolution X-ray diffraction analysis, the crystalline perfection of the grown crystal has been studied. Single crystal X-ray diffraction analyses, Nuclear Magnetic Resonance spectral analysis, Thermo-Gravimetry (TG), Differential Thermal Analysis (DTA) and hardness test have been employed to characterize the as-grown crystals. The UV cutoff wavelength of the grown crystal is below 300 nm and has a wide transparency window, which is suitable for second harmonic generation of laser in the blue region. Nonlinear optical characteristics have been studied using Q switched Nd:YAG laser (#lambda#=1064 nm). The second harmonic generation conversion efficiency of the grown crystals confirms their suitability for frequency conversion applications.

2010-12-15

397

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and cerebello-pontine angle. HRCT best depicts osseous ...

2003-03-01

398

Characterization of systems active in selective catalytic reduction of NO{sub x}  

Energy Technology Data Exchange (ETDEWEB)

This thesis is in the field of gas emission control from automobile and stationary sources. Out of the possible approaches to the elimination of pollutant gases, such as nitrogen oxides (NO{sub x}), one consists in the selective catalytic reduction (SCR) of these NO{sub x} on a suitable heterogeneous catalyst. Ammonia or hydrocarbons are employed as reducing agents. The most important catalysts active in the SCR of NO{sub x} are based on ions of transition metal either supported on several oxides or dispersed in zeolites. The catalysts have been characterized by electron magnetic resonance techniques (EPR, ENDOR, ESEEM) and the interaction of catalysts with nitrogen oxides, with reducing and poisoned agents have been followed with the same techniques. Copper dispersed on alumina and its interaction with both NO and ammonia has been investigated. Also the interaction between both water and ammonia with copper dispersed in zeolite ZSM-5 has been ...

1998-06-01

399

Beam-breakup calculations for the Los Alamos free-electron laser (FEL) linac  

International Nuclear Information System (INIS)

In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode acts to deflect the beam, and further assumes that this mode does not couple from one accelerating cavity to the next.

400

Application of spectroscopic techniques for the study of paper documents: A survey  

International Nuclear Information System (INIS)

For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear ...

2009-06-01

401

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...

1998-02-01

402

An availability of brain magnetic resonance imaging (MRI) in the early diagnosis of latent hepatic encephalopathy  

Energy Technology Data Exchange (ETDEWEB)

Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An improvement of this MRI finding was not observed by long-term oral administration of ...

1996-03-01

403

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research ...

2009-03-15

404

A fluorescent aminolipid from a green photosynthetic bacterium  

Energy Technology Data Exchange (ETDEWEB)

A preliminary chemical characterization is presented of phosphate-free aminolipids isolation from Chlorobium limicola f. thiosulfatophilum. The lipid contains no phosphorus, glycerol, sugar, ornithine, or lysine. Ultraviolet absorption and fluorescence spectra indicate that the amino moiety of the lipid is an aromatic heterocyclic compound. Infrared spectra indicate that the lipid is a secondary or tertiary amide, and gas chromatograhic analysis of the hydrolyzed lipid shows that for each 1100 g of lipid, 1 mol of myristic acid (C/sub 14:0/) is linked in an amide bond. Acid hydrolysis of the lipid yields two fluorescent substances, A (ninhydrine positive) and B (negative), in addition to myristic acid. Proton nuclear magnetic resonance (NMR) studies indicate that substance A contains a butyl groups attached to a conjugated ring carbon, two equivalent ethyl groups attached to one or two nitrogen atoms, and two downfield protons (8.4 ppm), ...

1983-04-12

405

#beta#-sialon via carbothermal reduction using brown coal  

International Nuclear Information System (INIS)

There has been a good deal of interest in the sialon system of ceramics in recent years due to their combination of important engineering properties #beta# including strength, hardness, low thermal expansion and good thermal shock resistance. #beta#-sialon (Si_6_-_zAl_zO_zN_8_-_z ;0Magnetic Resonance techniques in determining the nature of intermediate phases which occur. 9 refs., 1 tab., 1 fig.

406

Stable atomic structure and magnetism of Pt-Cr binary surface alloys on Pt(0 0 1): First-principle calculations  

International Nuclear Information System (INIS)

The possibility of Pt-Cr surface alloys formation on Pt(0 0 1) was investigated and their magnetism was calculated by the full-potential linearized augmented plane wave (FLAPW) method with eight different atomic configurations. The most stable structure was calculated to be the Pt-segregated L1_2 ferromagnetic surface alloy. A_3B types (L1_2 or D0_2_2) were more stable compared to AB types (L1_0). It implies that the A_3B type surface alloys may be formed when depositing a monolayer of Cr on Pt(0 0 1). It was found from the total energy calculations that there exists a strong tendency of the Pt segregation. The segregation further stabilizes the surface alloy significantly. The work function of the most stable surface alloy was calculated to be 6.02 eV and the magnetic moment of the surface Cr was much enhanced to 3.3 #mu# _B. It is a quite interesting finding that the coupling between Cr and Pt atoms on the surface plane ...

2006-09-01

407

RESOLVING DOPPLER-FACTOR CRISIS IN ACTIVE GALACTIC NUCLEI: NON-STEADY MAGNETIZED OUTFLOWS  

International Nuclear Information System (INIS)

Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission should correlate with the gamma-ray emission, delayed with frequency-dependent time lag ...

2010-10-10

408

Neutron scattering studies of mixed-valence semiconductors  

Energy Technology Data Exchange (ETDEWEB)

Neutron scattering experiments on the mixed-valence (MV) compounds SmB{sub 6} are reported. The inelastic magnetic response of SmB{sub 6} at T = 2 K, measured on a double-isotope single crystal,displays a strongly damped peak at 35 meV corresponding to the inter multiplet transition of Sm{sup 2+}. At lower energies ( h.{omega} {approx_equal} 14 meV), a narrow magnetic excitation is observed, with remarkable scattering-vector and temperature dependences of its intensity. This novel feature is discussed in terms of recent theoretical works describing the formation of an anisotropic local bound state in semiconducting MV materials. If the average samarium valence is decreased by substituting La for Sm, a peak is found to appear at high energies. The elastic magnetic form factor of SmB{sub 6} was determined using polarised neutrons and no significant difference is observed in its Q-dependence with respect to that of pure ...

1994-12-31

409

Negative ion source electrode  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a negative ion source electrode which can be preferably used in a neutral particle injection device using negative ions for a thermonuclear reactor. Negative ion beams are deflected to the direction opposite to the deflecting direction by magnetic fields by using an electron suppression electrode having electrode holes with the position previously displaced before negative ion beams are accelerated to have a high energy by an accelerator thereby correcting the orbit of the negative ion beams easily. In addition, since the deflection correction electrode having the electrode holes is disposed, a proper voltage is applied to the deflection correction electrode to correct the orbit of the negative ion beams conveniently. Since the deflection correction electrode has a simple structure of a thin flat plate having electrode holes, the orbit of negative ion beams can be corrected efficiently by an extremely simple structure without inducing ...

1997-01-17

410

Nanocrystallization of soft magnetic Fe-Co-Zr-Cu-B alloys  

International Nuclear Information System (INIS)

In the present study, Fe_4_1Co_4_1 B_1_0Zr_7Cu_1 alloy has been investigated in order to evaluate its thermal stability and structure after heat treatment, as well as the impact of heat treatment on magnetic properties. X-ray diffractometry, differential scanning calorimetry, chemical composition microanalysis, transmission electron microscopy, and magnetic hysteresis loop measurement techniques were employed. The crystallization temperature of the as-quenched alloy is 490"oC (continuous heating at 5 "oC/min). The melt spun ribbon having 27 #mu#m in thickness was annealed for 1 hour at temperatures from 400 to 700 "oC. The alloy after treatment at about 550"oC underwent primary crystallization, with the average size of crystals under 20 nm. This specimen shows the coercive field of 38 A/m, as compared to about 160 A/m reported for a similar alloy (Fe_4_4Co_4_4B_4Zr_7Cu_1) with a similar structure, annealed at 600"oC. ...

2001-09-23

411

Intensification of harmonic spontaneous radiation with a novel undulator  

International Nuclear Information System (INIS)

We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessivecurrent in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeV electrons taking K1 is greatly enhanced for the approximate square-wave magnetic profile: the ratio of the power emitted at f=5 by the square-wave undulator to that of the ...

1999-07-01

412

Intensification of Harmonic Spontaneous Radiation with a Novel Undulator  

Science.gov (United States)

We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessive current in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeV electrons taking K < 1, for spontaneous radiation emitted along the axis of the system. The emission at harmonics f > 1 is greatly enhanced for the approximate square-wave ...

1998-11-01

413

Does hybrid density functional theory predict a non-magnetic ground state for ?-Pu?  

Science.gov (United States)

Hybrid density functionals, which replace a fraction of density functional theory (DFT) exchange with exact Hartree-Fock (HF) exchange, have been used to study the structural, magnetic, and electronic properties of ?-Pu. The fractions of exact Hartree-Fock exchange used were 25%, 40%, and 55%. Compared to the pure PBE functional, the lattice constants expanded with respect to the experimental value when the PBE-HF hybrid functionals were applied. For pure PBE and hybrid functionals with HF exchanges amounts of 25% and 40%, the ground state structure was anti-ferromagnetic, while for 55% HF contribution the ground state was non-magnetic. The 5f electrons tend to exhibit slight delocalization or itinerancy for the pure PBE functional and well-defined localization for the hybrid functionals, with the degree of 5f electron localization increasing with the amount of HF exchange. Overall, the performance of the hybrid density ...

2009-01-01

414

Does hybrid density functional theory predict a non-magnetic ground state for #delta#-Pu?  

International Nuclear Information System (INIS)

Hybrid density functionals, which replace a fraction of density functional theory (DFT) exchange with exact Hartree-Fock (HF) exchange, have been used to study the structural, magnetic, and electronic properties of #delta#-Pu. The fraction of exact Hartree-Fock exchange used were 25%, 40%, and 55%. Compared to the pure PBE functional, the lattice constants expanded with respect to the experimental value when the PBE-HF hybrid functionals were applied. For pure PBE and hybrid functionals with HF exchanges amounts of 25% and 40%, the ground state structure was anti-ferromagnetic, while for 55% HF contribution the ground state was non-magnetic. The 5f electrons tend to exhibit slight delocalization of itinerancy for the pure PBE functional and well-defined localization for the hybrid functionals, with the degree of 5f electron localization increasing with the amount of HF exchange. Overall, the performance of the hybrid ...

2009-01-01

415

A Wide-Band Electromagnetic Impedance Profiling System forNon-Invasive Subsurface Characterization  

Energy Technology Data Exchange (ETDEWEB)

A non-invasive, wide-band electromagnetic (EM) impedance difference system for shallow subsurface electrical structure characterization in environmental and engineering problems has been developed at the Lawrence Berkeley National Laboratory (LBNL). Electrical parameters of interest are electrical conductivity and dielectric permittivity that are deduced from the impedance difference data. The prototype system includes a magnetic loop transmitter, which operates between 0.1 MHz and 100 MHz, an electrical dipole antenna for observing the electric field, and a loop antenna for measuring the magnetic field.All antennas are mounted on a cart made of non-metallic material for easy movement of the whole array for profiling. Surface EM impedance difference is obtained by taking the difference of the ratios of the electric fields to the magnetic fields at selected frequencies at two different levels. Numerical simulations will be ...

2004-12-17

416

/sup 242/Am/sup m/ fission cross section  

Energy Technology Data Exchange (ETDEWEB)

The neutron-induced fission cross section of /sup 242/Am/sup m/ has been measured over the energy region from 10/sup -3/ eV to approx.20 MeV in a series of experiments utilizing a linac-produced ''white'' neutron source and a monoenergetic source of 14.1 MeV neutrons. The cross section was measured relative to that of /sup 235/U in the thermal (0.001 to approx.3 eV) and high energy (1 keV to approx.20 MeV) regions and normalized to the ENDF/B-V /sup 235/U(n,f) evaluated cross section. In the resonance energy region (0.5 eV to 10 keV) the neutron flux was measured using thin lithium glass scintillators and the relative cross section thus obtained was normalized to the thermal energy measurement. This procedure allowed a consistency check between the thermal and high energy data. The cross section data have a statistical accuracy of approx.0.5% at thermal energies and in the 1-MeV energy region, and a systematic uncertainty of ...

1984-06-01

417

The role of interventional radiology in management of patients with end-stage renal disease  

Energy Technology Data Exchange (ETDEWEB)

The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...

2003-05-01

418

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution in the z-axis. ...

2006-04-15

419

Electron cyclotron heating  

International Nuclear Information System (INIS)

Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented ...

420

Resonance Raman enhancement of phenyl ring vibrational modes in phenyl iron complex of myoglobin.  

UK PubMed Central (United Kingdom)

Resonance Raman spectra are reported for the organometallic phenyl-FeIII complexes of horse heart myoglobin. We observed the resonance enhancement of the ring vibrational modes of the bound phenyl group....Full Text Available

1990-04-01

421

VIS harvesting unsymmetrical squaraine dye for dye-sensitized solar cells  

British Library Electronic Table of Contents (United Kingdom)

An unsymmetrical squaraine dye which contains an arylamino group was synthesized and used in dye-sensitized solar cells. The molar extinction coefficient of the dye is 77793 M-1 cm-1. Because our synthesized molecule may have no diradical character or the contribution of the diradicaloid component to resonance is quite small, the newly designed squaraine dye has a maximum absorption at 546 nm in the visible region compared with the NIR squaraine sensitizers. Cyclic voltammetry and time dependent density function theory calculation were accomplished to scrutinize the sensitized performance of the dye. Meanwhile, the novel sensitizer has been used to sensitize nanocrystalline TiO2-based solar cell. Under standard global AM 1.5 solar conditions, the squaraine dye-sensitized cell gives a short...

2012-01-01

422

The {sup 234}U neutron capture cross section measurement at the n TOF facility  

Energy Technology Data Exchange (ETDEWEB)

The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)

2008-07-01

423

Terahertz time-domain spectroscopy of atmospheric water vapor from 0.4 to 2.7 THz.  

Energy Technology Data Exchange (ETDEWEB)

We conducted broadband absorption measurements of atmospheric water vapor in the ground state, X {sup 1}A{sub 1} (000), from 0.4 to 2.7 THz with a pressure broadening-limited resolution of 6.2 GHz using pulsed, terahertz time-domain spectroscopy (THz-TDS). We measured a total of seventy-two absorption lines and forty-nine lines were identified as H{sub 2}{sup 16}O resonances. All the H{sub 2}{sup 16}O lines identified were confirmed by comparing their center frequencies to experimental values available in the literature.

2005-10-01

424

Studies on ball screw type damper with flyball governor, 1st report  

International Nuclear Information System (INIS)

The forced nonlinear vibration and its stability of a single-degree-of-freedom system with a ball screw type damper which is composed of a ball screw, a flywheel and a flyball governor are discussed theoretically. The results are compared with a linear solution and the experimental results. The effect of vibration isolation of the damper is also discussed. Numerical examples are given for several ratios of the natural frequencies in the primary system to the governor. It is demonstrated that, when the natural frequency ratio is chosen suitably, the damper is effective in suppressing the resonance of the primary system. The amplitude response curve of the primary system is approximately equal to the linear solution except in the vicinities of the natural frequencies of the primary system and the governor, and is stable except in the vicinity of the natural frequency of the governor. (author).

1986-01-01

425

Small hemielliptic dielectric lens antenna analysis in 2-D: boundary integral equations versus geometrical and physical optics  

CERN Document Server

We assess the accuracy and relevance of the numerical algorithms based on the principles of Geometrical Optics (GO) and Physical Optics (PO) in the analysis of reduced-size homogeneous dielectric lenses prone to behave as open resonators. As a benchmark solution, we use the Muller boundary integral equations discretized with trigonometric Galerkin scheme that has guaranteed and fast convergence as well as controllable accuracy. The lens cross-section is chosen typical for practical applications, namely an extended hemiellipse whose eccentricity satisfies the GO focusing condition. The analysis concerns homogeneous lenses made of rexolite, fused quartz, and silicon with the size varying between 3 and 20 wavelengths in free space. We consider the 2-D case with both E- and H-polarized plane waves under normal and oblique incidence, and compare characteristics of the near fields.

2010-01-01

426

Resonant CP violation in MSSM Higgs production and decay at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We study CP-violating phenomena in the production, mixing and decay of a coupled system of CP-violating neutral Higgs bosons at {gamma}{gamma} colliders, assuming a Minimal Supersymmetric Standard Model (MSSM) Higgs sector in which CP violation is radiatively induced by phases in the soft supersymmetry-breaking gaugino masses and third-generation trilinear squark couplings. We discuss CP asymmetries in the production and decays of {mu}{sup +}{mu}{sup -}, {tau}{sup +}{tau}{sup -}, b-bar b and t-bar t pairs. We find large asymmetries when two (or all three) neutral Higgs bosons are nearly degenerate with mass differences comparable to their decay widths, as happens naturally in the CP-violating MSSM for values of tan{beta}-bar 5 (30) and large (small) charged Higgs-boson masses.

2005-07-04

427

Resonant CP violation in MSSM Higgs production and decay at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study CP-violating phenomena in the production, mixing and decay of a coupled system of CP-violating neutral Higgs bosons at #gamma##gamma# colliders, assuming a Minimal Supersymmetric Standard Model (MSSM) Higgs sector in which CP violation is radiatively induced by phases in the soft supersymmetry-breaking gaugino masses and third-generation trilinear squark couplings. We discuss CP asymmetries in the production and decays of #mu#"+#mu#"-, #tau#"+#tau#"-, b-bar b and t-bar t pairs. We find large asymmetries when two (or all three) neutral Higgs bosons are nearly degenerate with mass differences comparable to their decay widths, as happens naturally in the CP-violating MSSM for values of tan#beta#-bar 5 (30) and large (small) charged Higgs-boson masses.

2005-07-04

428

Quantum Particle Swarm Optimization for Electromagnetics  

CERN Document Server

A new particle swarm optimization (PSO) technique for electromagnetic applications is proposed. The method is based on quantum mechanics rather than the Newtonian rules assumed in all previous versions of PSO, which we refer to as classical PSO. A general procedure is suggested to derive many different versions of the quantum PSO algorithm (QPSO). The QPSO is applied first to linear array antenna synthesis, which is one of the standard problems used by antenna engineers. The performance of the QPSO is compared against an improved version of the classical PSO. The new algorithm outperforms the classical one most of the time in convergence speed and achieves better levels for the cost function. As another application, the algorithm is used to find a set of infinitesimal dipoles that produces the same near and far fields of a circular dielectric resonator antenna (DRA). In addition, the QPSO method is employed to find an equivalent circuit model ...

2006-01-01

429

Performance of a diode-pumped laser repetitively Q-switched with a mechanical shutter.  

Science.gov (United States)

Repetitively Q-switched operation of an end-pumped Nd:YAG laser over the range of 200 Hz to 3 kHz using an intracavity chopper is demonstrated. Performance is shown to be comparable to that achieved with an acousto-optic Q switch under similar conditions. The advantages and limitations of the mechanical Q switch are described. Parametric variations of output coupling and pump power lead to an extended empirical description of repetitively Q-switched laser operation. The insertion loss as a function of aperture-edge penetration into the resonator is reported, and a definition of the mechanical Q-switch opening time is provided. Q-switched pulsewidths as short as 35 ns were obtained for the Nd:YAG laser, with a peak power-enhancement factor in excess of 300. PMID:20862099

1994-02-20

430

Optimized chatter resistance of viscoelastic turning bars  

British Library Electronic Table of Contents (United Kingdom)

The regenerative-chatter resistance of a viscoelastic cantilever beam is analyzed and compared to the common dynamic vibration absorber (DVA) system. The beam represents a tool holder for turning operation in machining. The optimum structural parameters are found by maximizing the most negative real part of the frequency response function (FRF). The FRF is found analytically by using an appropriate Greens function. Keeping the cantilever static stiffness constant, further increase in the optimal resistance is achieved by changing the ratio between the two elastic moduli in the 3-parameter solid viscoelastic material model. Three additional chatter resistance indicators are also investigated: the most positive real part of the FRF, the magnitude of the FRF and the resonant frequency. It is ...

2009-01-01

431

On the temperature sensing capability of a fibre optic SPR mechanism based on bimetallic alloy nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

In this work, we have investigated the capability of different bimetallic nanoparticle alloy combinations to be used in fibre optic temperature sensing based on the technique of surface plasmon resonance (SPR). The metals considered for the present analysis are silver, gold and aluminium. The analysis is derived mainly from the thermo-optic effect along with some fundamental concepts of metal optics such as surface scattering, phonon-electron scattering and electron-electron scattering. The performance of the sensor with three different bimetallic nanoparticle alloy combinations is evaluated and compared, numerically, in terms of its sensitivity and accuracy. On the basis of the comparison and some logistic criterion, we predict the best possible bimetallic alloy combination along with a requisite alloy composition ratio that simultaneously provides higher values of both sensitivity and accuracy which is not possible with any single metallic ...

2009-02-21

432

Gluino-Squark Production at the LHC: The Threshold  

CERN Document Server

An analysis of the cross section for hadronic production of gluino-squark pairs close to threshold is presented. Within the framework of non-relativistic QCD a significant enhancement compared to fixed order perturbation theory is observed which originates from the characteristic remnants of the gluino-squark resonances below the nominal pair threshold. The analysis includes all colour configurations of S-wave gluino-squark pairs, i.e. triplet, sextet and 15 representation. Matching coefficients at leading order are separately evaluated for all colour configurations. The dominant QCD corrections, arising from initial- and final-state radiation are included. The non-relativistic dynamics of the gluino pair is solved by calculating the Green's function in Next-to-Leading Order (NLO). The results are applied to benchmark scenarios, based on Snowmass Points and Slopes (SPS). As a consequence of the large decay rate of at least one of the ...

2011-01-01

433

Ge/Si nanowire mesoscopic Josephson junctions  

CERN Document Server

The controlled growth of nanowires (NWs) with dimensions comparable to the Fermi wavelengths of the charge carriers allows fundamental investigations of quantum confinement phenomena. Here, we present studies of proximity-induced superconductivity in undoped Ge/Si core/shell NW heterostructures contacted by superconducting leads. By using a top gate electrode to modulate the carrier density in the NW, the critical supercurrent can be tuned from zero to greater than 100 nA. Furthermore, discrete sub-bands form in the NW due to confinement in the radial direction, which results in stepwise increases in the critical current as a function of gate voltage. Transport measurements on these superconductor-NW-superconductor devices reveal high-order (n = 25) resonant multiple Andreev reflections, indicating that the NW channel is smooth and the charge transport is highly coherent. The ability to create and control coherent superconducting ordered states ...

2006-01-01

434

Gamma-rays and neutrinos from the pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab Nebula.

2005-08-01

435

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

436

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

437

Enhanced inactivation of bacteria by metal-oxide nanoparticles combined with visible light irradiation  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground In recent years nano-metaloxides which easily penetrate into the cells with special interest due to their higher chemical reactivity as compared to that of similar materials in the bulk form. Of particular interest are nano-TiO2 and ZnO, which have been widely used for their bactericidal and anticancerous properties. Purpose The aim of the present study was to examine the bactericidal properties of nano-TiO2 and ZnO combined with visible light on S. aureus and S. epidermitis, known for their high prevalence in infected wounds. Study Using the technique of electron-spin resonance (ESR) coupled with spin trapping, we examined the ability of TiO2 and ZnO nanoparticle suspensions in water to produce reactive oxygen species (ROS) with and without visible light irradiation. Th...

2011-01-01

438

Energy transfer study of europium-tetracycline complexes  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work was to study the energy transfer mechanisms from the ligand to the central lanthanide ion of tetracycline-europium (Tc-Eu) complex. The absorption spectra of a EuCl{sub 3}.H{sub 2}O solution was measured and absorption cross-section of Eu{sup 3+} was estimated. The observed overlap predicts a resonant energy transfer from Tetracycline to Eu{sup 3+}. The microscopic parameter of energy transfer was obtained using the overlap integral calculation considering a dipole-dipole energy transfer mechanism and results were compared considering an energy transfer by exchange. In this work, we report also the optical properties of Tc-Eu complex when urea hydrogen peroxide is added to the aqueous solution.

2007-01-15

439

Dissipative dynamics of circuit-QED in the mesoscopic regime  

CERN Document Server

We investigate the behavior of a circuit QED device when the resonator is initially populated with a mesoscopic coherent field. The strong coupling between the cavity and the qubit produces an entangled state involving mesoscopic quasi-pointer states with respect to cavity dissipation. The overlap of the associated field components results in collapse and revivals for the Rabi oscillation. Although qubit relaxation and dephasing do not preserve these states, a simple analytical description of the dissipative dynamics of the circuit QED device including cavity relaxation as well as qubit dissipation is obtained from the Monte-Carlo approach. Explicit predictions for the spontaneous and induced Rabi oscillation signals are derived and sucessfully compared with exact calculations. We show that these interesting effects could be observed with a 10 photon field in forthcoming circuit QED experiments.

2007-01-01

440

Chiral perturbation theory calculation for pn {yields}d{pi} {pi} at Threshold  

Energy Technology Data Exchange (ETDEWEB)

We investigate the reaction pn {yields}d{pi} {pi} in the framework of Chiral Perturbation Theory (ChPT). For the first time a complete calculation of the leading-order contributions is presented. We identify various diagrams that are of equal importance as compared to those recognized in earlier works. The diagrams at leading order behave as expected by the power counting. Also for the first time the nucleon-nucleon interaction in the initial, intermediate and final state is included consistently and found to be very important. Although the perturbative series for the production operator is expected to converge very slowly, this study provides the theoretical basis for a future evaluation of the non-resonant contributions in two-pion production reactions in nucleon-nucleon collisions. (orig.)

2011-01-15

441

Analysis of recent {eta} photoproduction data  

Energy Technology Data Exchange (ETDEWEB)

Recent data on {eta} -meson photoproduction off a proton target in the energy range 2 {<=}{radical}(s){<=} 3 GeV are analyzed with regard to their overall consistency. Results from the ELSA and CLAS measurements are compared with predictions of a Regge model whose reaction amplitude was fixed via a global fit to pre-2000 measurements of differential cross sections and polarization observables for {gamma}p{yields}{eta}p at higher energies. We find that all recent experimental results on differential cross sections for {eta} -meson photoproduction are in good agreement with each other, except for the CLAS data from 2009. However, the latter can be made consistent with the other data at the expense of introducing an energy-dependent renormalization factor. We point out that there are indications in the data for a possible excitation of baryon resonances with masses around 2.1 and 2.4GeV. (orig.)

2010-12-15

442

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

Energy Technology Data Exchange (ETDEWEB)

Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

443

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

International Nuclear Information System (INIS)

Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

444

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

445

Interference phenomena at the elastic collision of atoms with formation of the Feshbach resonance in the presence of laser radiation field  

British Library Electronic Table of Contents (United Kingdom)

Resonant scattering of atoms with formation of the Feshbach resonance in the presence of a laser radiation coupling the levels of two bound atoms (a molecule) is considered. The laser field leads to a second resonance in scattering and broadening of resonances, which facilitates the possibility of experimental observation of asymmetry of the total scattering cross-section arising because of interference between resonant and potential scatterings. The effects associated with interference of the two channels of decay of a bound system of two atoms (a molecule) in the laser field are studied. An expression is obtained for the scattering length in collision of two cold atoms in the field of laser radiation.

2011-01-01

446

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

447

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

448

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

449

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

450

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

452

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

453

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

455

Inelastic electron scattering, M1 giant resonances and the quest for subnuclear degrees of freedom  

International Nuclear Information System (INIS)

... electrons fine structure giant resonance inelastic scattering iron 54 iron 54

1983-01-17

456

The electronic structure of organometallic complexes of the f elements XXV. Crystal field splitting pattern of the anionic complex [Cp_3Pr. NCS]"-  

International Nuclear Information System (INIS)

The absorption, emission and magnetic circular dichroism spectra of the anionic complex (Cp_3Pr. NCS)"- were measured at room and low temperatures. On the basis of these spectra the electronic structure in the f-f range could be derived. The parameters of an empirical Hamiltonian were fitted to the experimentally determined crystal field splitting pattern. Compared with the previously examined neutral Cp_3 Pr.X complexes the quadratic crystal field parameter B_0"2 is considerably reduced.

457

Spectroscopy of neutron-rich Fe isotopes populated in the "6"4Ni+"2"3"8U reaction  

International Nuclear Information System (INIS)

The neutron-rich Fe isotopes from A=61 to 66 were studied through multinucleon transfer reactions by bombarding a "2"3"8U target with a 400 MeV "6"4Ni beam. Unambiguous identification of prompt #gamma# rays belonging to each nucleus was achieved using coincidence relationships with the ions detected in a high-acceptance magnetic spectrometer. The new data extend our knowledge of the level structure of Fe isotopes, which is discussed in terms of the systematics of the region and compared with large-scale shell-model calculations.

2007-09-01

458

On the validity of the pseudo-spin concept for axially symmetric deformed nuclei  

International Nuclear Information System (INIS)

The average single-particle field shows a very small pseudo-spin-orbit splitting in the pseudo-spin representation. If this splitting is neglected, pseudo-spin becomes a good quantum number and the resulting scheme (the pseudo-Nilsson model) has a very simple interpretation. The pseudo-spin symmetry embodied in the realistic deformed average field is explored by comparing the single-particle energies and wave functions of the deformed Woods-Saxon model with the corresponding results of the pseudo-Nilsson model. The scheme is used to calculate the magnetic moments of deformed odd-A nuclei of the rare-earth region. (orig.).

459

Negative snakes in JET: evidence for negative shear  

Energy Technology Data Exchange (ETDEWEB)

The signature of the negative snakes from the soft X-ray cameras is very similar to the more usual snakes except that the localised region of the snake has, compared with its surroundings, decreased rather than increased emission. Circumstances where negative snakes have been seen are reviewed. The negative snake appears as a region of increased resistance and of increased impurity density. The relationship between the shear and the current perturbation is shown, and it seem probable that the magnetic shear is reversed at the point of the negative snake, i.e. that q is decreasing with radius. 6 refs., 6 figs.

1994-07-01

460

Ion temperature gradient modes in toroidal helical systems  

Energy Technology Data Exchange (ETDEWEB)

Linear properties of ion temperature gradient (ITG) modes in helical systems are studied. The real frequency, growth rate, and eigenfunction are obtained for both stable and unstable cases by solving a kinetic integral equation with proper analytic continuation performed in the complex frequency plane. Based on the model magnetic configuration for toroidal helical systems like the Large Helical Device (LHD), dependences of the ITG mode properties on various plasma equilibrium parameters are investigated. Particularly, relative effects of {nabla}B-curvature drifts driven by the toroidicity and by the helical ripples are examined in order to compare the ITG modes in helical systems with those in tokamaks. (author)

2000-04-01

461

Hybridisation and crystal field in YbPd sub 2 Si sub 2  

Energy Technology Data Exchange (ETDEWEB)

Experimental data in the hybridised compound YbPd{sub 2}Si{sub 2} is compared with the results obtained with a recently proposed hybridisation model, based on the ''large-degeneracy expansion'' approximation, which takes into account the crystal field splittings of the rare earth ion energy levels. With a unique set of parameters, satisfactory agreement is simultaneously obtained for the thermal variation of the electronic specific heat, of the magnetic susceptibility and of the electric field gradient at the Yb site, as well as for the field variation of the low temperature magnetisation. (orig.).

1991-02-01

462

HTSC devices fabricated by selective epitaxial growth  

International Nuclear Information System (INIS)

The use of a selective epitaxial growth technique for fabricating YBCO thin-film microstructures is described. No film post-deposition processing is required; hence damage to the structure is minimized. The technique is compatible with a passivation process to protect the structure without exposure to air. The microbridges, Josephson junctions and rf SQUIDs protected by an amorphous YBCO passivation have long lifetime even after severe accelerated aging tests. Rf SQUIDs fabricated by this technique show a significant reduction of low-frequency noise when operating in weak magnetic fields compared with SQUIDs fabricated by the conventional ion beam etching technique. (author)

1999-04-01

463

Detection of EDM defects under Monju support plate using experimental data from remote field eddy current probes and a multi-frequency algorithm  

International Nuclear Information System (INIS)

This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)

2006-07-01

464

Asymmetric rotor model for decoupled bands in transitional odd-mass nuclei  

International Nuclear Information System (INIS)

The high-spin states in transitional odd-mass nuclei are studied in terms of an odd quasi-particle coupled to an asymmetric rotor with a variable moment of inertia (VMI). In order to take into account the VMI, the basis states are expanded in terms of the core eigenfunctions. Excitation energies, quadrupole moments, magnetic moments, B(E2) values and B(M1) values are calculated and compared with the experimental data for nuclei in Au and La regions. On comparison with other descriptions it is found that the treatment with VMI provides a more satisfactory explanation of the data. (Auth.).

465

A phenomenological Landau theory for electromagnons in cubic spinel multiferroic CoCr_2O_4  

International Nuclear Information System (INIS)

Non-anisotropic free energy is considered which under minimization yields two magnetic phases: a conical spin density wave and a low temperature conical cycloid. Using equations of motion, the excitation spectrum is studied. Knowing the nature of these excitations, the dielectric function as well as the fluctuation specific heat is computed and compared with the experimental spectrum. Due to the electromagnon going soft, the dielectric function (imaginary part) as well as the specific heat capacity show peaks at the temperature where ferroelectricity appears in the system.

2010-06-09

466

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...

2009-03-01

467

Intrinsic magnetism in Fe doped SnO2 nanoparticles  

International Nuclear Information System (INIS)

Iron doped semiconducting nanoparticles Sn1-xFexO2 with x=0, 0.001, 0.002, 0.003, 0.004, 0.01 and 0.03 were prepared by a sol-gel method. The X-ray diffraction, Transmission Electron Microscopy measurements confirm the rutile structure with no impurity phase. The three characteristic lines of electron spin resonance (ESR) are observed in the doped samples for all compositions, which is a clear evidence for rhombic Fe3+ in rutile phase. The line width of ESR increases with increase in Fe concentration due to induced disorder. The spin-pumping effect is observed at temperatures below 250 K for the samples with x=0.01 and 0.03. However, based on the Curie-Weiss susceptibility, iron is in paramagnetic state and is subject to weak antiferromagnetic interaction. Blue shift in the optical band gap is observed with increase in the Fe content. -- Graphical abstract: The ESR spectra reveal that the nature of Fe in Sn1-xFexO2 samples is isolated rhombic Fe3+-ion in rutile ...

2011-01-01

468

Lattice calculation of nonleptonic charm decays  

Energy Technology Data Exchange (ETDEWEB)

The decays of charmed mesons into two body nonleptonic final states are investigated. Weak interaction amplitudes of interest in these decays are extracted from lattice four-point correlation functions using a effective weak Hamiltonian including effects to order G{sub f} in the weak interactions yet containing effects to all orders in the strong interactions. The lattice calculation allows a quantitative examination of non-spectator processes in charm decays helping to elucidate the role of effects such as color coherence, final state interactions and the importance of the so called weak annihilation process. For D {yields} K{pi}, we find that the non-spectator weak annihilation diagram is not small, and we interpret this as evidence for large final state interactions. Moreover, there is indications of a resonance in the isospin {1/2} channel to which the weak annihilation process contributes exclusively. Findings from the lattice calculation are ...

1991-11-01

469

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are ...

2004-11-01

470

Spin resonance strength calculations  

Energy Technology Data Exchange (ETDEWEB)

In calculating the strengths of depolarizing resonances it may be convenient to reformulate the equations of spin motion in a coordinate system based on the actual trajectory of the particle, as introduced by Kondratenko, rather than the conventional one based on a reference orbit. It is shown that resonance strengths calculated by the conventional and the revised formalisms are identical. Resonances induced by radiofrequency dipoles or solenoids are also treated; with rf dipoles it is essential to consider not only the direct effect of the dipole but also the contribution from oscillations induced by it.

2008-10-06

471

Nuclear physics with a free electron laser  

International Nuclear Information System (INIS)

... radiation parity photonuclear reactions polarized beams resonance

474

Free radicals in lysozyme reacted with peroxidizing methyl linoleate  

International Nuclear Information System (INIS)

... electron spin resonance gamma radiation lipids lyophilization lysozyme radicals

480

Global mode analysis of ideal MHD modes in a heliotron/torsatron system. 1. Mercier-unstable equilibria  

Energy Technology Data Exchange (ETDEWEB)

By means of a global mode analysis of ideal MHD modes for Mercier-unstable equilibria in a planar axis L=2/M=10 heliotron/torsatron system with an inherently large Shafranov shift, the conjecture from local mode analysis for Mercier-unstable equilibria given in [N. Nakajima, Phys. Plasmas 3, 4556 (1996)] has been confirmed and the properties of pressure-driven modes, namely, ballooning modes and interchange modes, inherent to such three-dimensional systems have been clarified. The change of the local magnetic shear due to the Shafranov shift, which is related to toroidicity, reduces the field line bending stabilizing effects on ballooning modes. According to the degree of the reduction of the local magnetic shear by the Shafranov shift, the Mercier-unstable equilibria are categorized into toroidicity-dominant (strong reduction) and helicity-dominant (weak reduction) Mercier-unstable equilibria. Since the local magnetic ...

1998-12-01

481

Photon shell game in three-resonator circuit quantum electrodynamics  

CERN Document Server

The generation and control of quantum states of light constitute fundamental tasks in cavity quantum electrodynamics (QED). The superconducting realization of cavity QED, circuit QED, enables on-chip microwave photonics, where superconducting qubits control and measure individual photon states. A long-standing issue in cavity QED is the coherent transfer of photons between two or more resonators. Here, we use circuit QED to implement a three-resonator architecture on a single chip, where the resonators are interconnected by two superconducting phase qubits. We use this circuit to shuffle one- and two-photon Fock states between the three resonators, and demonstrate qubit-mediated vacuum Rabi swaps between two resonators. This illustrates the potential for using multi-resonator circuits as photon quantum registries and for creating multipartite entanglement ...

2010-01-01

482

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...

1981-11-11

484

Magnetic braking of the rotation of molecular cloud cores  

International Nuclear Information System (INIS)

We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).

485

LHC magnet alignment  

CERN Document Server

Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.

2007-01-01

486

Determination of Scaling Parameter and Dynamical Resonances in Complex-Rotated Hamiltonian II: Numerical Analysis  

International Nuclear Information System (INIS)

This paper is concerned with the determination of a unique scaling parameter in complex scaling analysis and with accurate calculation of dynamics resonances. In the preceding paper we have presented a theoretical analysis and provided a formalism for dynamical resonance calculations. In this paper we present accurate numerical results for two non-trivial dynamical processes, namely, models of diatomic molecular predissociation and of barrier potential scattering for resonances. The results presented in this paper confirm our theoretical analysis, remove a theoretical ambiguity on determination of the complex scaling parameter, and provide an improved understanding for dynamical resonance calculations in rigged Hilbert space.

2008-03-15

487

New Forming Limits For Light Alloys By Means Of Electromagnetic Forming And Numerical Simulation Of The Process  

Science.gov (United States)

It is well known that one of the main advantages of the high speed forming (HSF) processes is the improvement in the forming limits of the used materials.Using the Electromagnetic Forming (EMF) technology two materials have been tested with different mechanical and physical properties: the AA5754 aluminium and the AZ31B magnesium alloys.The EMF process principle can be described as follows: A significant amount of electrical energy is stored in a bank of capacitors which are suddenly discharged releasing all the stored energy. This electric discharge runs through a coil which generates an intense transient magnetic field. At the same time transient Eddy currents are induced in the electrically conductive part placed some millimetres far from the coil. Another intense magnetic field is generated due to those Eddy currents but on the opposite direction as the one generated by the coil. A big magnetic repulsion force is ...

2007-04-07

488

New Forming Limits For Light Alloys By Means Of Electromagnetic Forming And Numerical Simulation Of The Process  

International Nuclear Information System (INIS)

It is well known that one of the main advantages of the high speed forming (HSF) processes is the improvement in the forming limits of the used materials.Using the Electromagnetic Forming (EMF) technology two materials have been tested with different mechanical and physical properties: the AA5754 aluminium and the AZ31B magnesium alloys.The EMF process principle can be described as follows: A significant amount of electrical energy is stored in a bank of capacitors which are suddenly discharged releasing all the stored energy. This electric discharge runs through a coil which generates an intense transient magnetic field. At the same time transient Eddy currents are induced in the electrically conductive part placed some millimetres far from the coil. Another intense magnetic field is generated due to those Eddy currents but on the opposite direction as the one generated by the coil. A big magnetic repulsion force is ...

2007-04-07

489

Magnetocaloric effect of Gd{sub 4}(Bi{sub x}Sb{sub 1{minus}x}){sub 3} alloy series  

Energy Technology Data Exchange (ETDEWEB)

Alloys from the Gd{sub 4}(Bi{sub x}Sb{sub 1{minus}x}){sub 3} series were prepared by melting a stoichiometric amounts of pure metals in an induction furnace. The crystal structure is of the anti-Th{sub 3}P{sub 4} type (space group I{bar 4}3d) for all the compounds tested. The linear increase of the lattice parameters with Bi concentration is attributed to the larger atomic radius of Bi than that of Sb. Magnetic measurements show that the alloys order ferromagnetically from 266K to 330K, with the ordering temperature increasing with decreasing Bi concentration. The alloys are soft ferromagnets below their Curie temperatures, and follow the Curie-Weiss law above their ordering temperatures. The paramagnetic effective magnetic moments are low compared to the theoretical value for a free Gd{sup 3+}, while the ordered magnetic moments are close to the theoretical value for Gd. The alloys exhibit a moderate ...

1999-12-01

490

Density separation of materials by using magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...

1980-03-01

491

Physical and optical properties of rare earth cobalt magnets  

Energy Technology Data Exchange (ETDEWEB)

Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.

1980-08-01

493

METHOD OF FORMING THIN MAGNETIC FILM  

J-STORE (Japan)

Full Text Available

2007-10-04

495

Observing Evolution in the Supergranular Length Scale During Periods of Low Solar Activity  

CERN Document Server

We present the initial results of an observational study into the variation of the dominant length-scale of quiet solar emission: supergranulation. This length-scale reflects the radiative energy in the plasma of the upper solar chromosphere and transition region at the magnetic network boundaries forming as a result of the relentless interaction of magnetic fields and convective motions of the Sun's interior. We demonstrate that a net difference of ~0.5Mm in the supergranular emission length-scale occurs when comparing observations cycle 22/23 and cycle 23/24 minima. This variation in scale is reproduced in the datasets of multiple space- and ground-based instruments and using different diagnostic measures. By means of extension, we consider the variation of the supergranular length-scale over multiple solar minima by analyzing a subset of the Mt Wilson Solar Observatory (MWO) Ca II K image record. The observations and ...

2011-01-01

496

Inductive technique for measuring critical current densities in thin-film superconductors  

Energy Technology Data Exchange (ETDEWEB)

A technique and a particular apparatus for an inductive measurement of critical currents as a function of temperature and magnetic field in thin-film superconductors are described. The technique has been found to be particularly useful for high-field A-15 compounds 2 to 3 ..mu..m thick. Samples with lower critical current densities would have to be correspondingly thicker to measure over the same broad range of temperature and field. The design of the apparatus is detailed showing that the film can be taken directly from the deposition chamber and mounted without electrical contacts so samples can be changed easily. The principles of operation are developed based on the Critical State Model. These principles are tested by measurements which verify that the measured value of critical curent is independent of the amplitudes and frequency of the small ac magnetic field which is added to a much larger quasistatic field. The inductive measurements ...

1983-01-01

497

Hybrid Density Functional Studies of ?-Pu  

Science.gov (United States)

Hybrid density functionals, which replaces a fraction of a density functional theory exchange with exact Hartree-Fock (HF) exchange, have been used to study the structural, magnetic, and electronic properties of ?-Pu. The fractions of exact Hartree-Fock exchange used were 25%, 40%, and 55%. Compared to the pure PBE functional, the lattice constants expanded with respect to the experimental value when the PBE-HF hybrid functionals were applied. For pure PBE and hybrids functionals with HF exchange amounts of 25% and 40%, the ground state structure was anti-ferromagnetic, while for 55% HF contribution the ground state was non-magnetic. The 5f electrons tend to exhibit slight delocalization or itinerancy for the pure PBE functional and well-defined localization for the hybrid functionals, with the degree of 5f electron localization increasing with the amount of HF exchange. Overall, the performance of the hybrid density ...

2009-03-01

498

Changes of magnetization transfer ratio according to rat brain development  

International Nuclear Information System (INIS)

We assessed the age-related changes in magnetization transfer ratio (MTR) value and the ratio of water content in rat brain (frontal lobe and pons) during normal development. All studies were done on 42 normal Wistar rats. MTR was calculated by using the equation (M_o_f_f-M_o_n)/M_o_f_f, where M_o_f_f and M_o_n were the measured signal intensities on the conventional and MT-prepared SPGR images, respectively. The ratios of water content were measured by comparing the wet weight with the dry weight of the frontal lobe and the pons, which were extracted from a rat brain soon after MTR measurements. The ratio of water content was calculated by using the equation 100 x (wet weight-dry weight)/wet weight (%). The ratio of water content decreased markedly during the first 30 days, but the decrease was very slight there after both in the frontal lobe and the pons. The change in MTR was similar to that of the ratio of water content, though the ...

499

Atomic spectroscopy study of nuclear properties of francium and cesium isotopes; Etude par spectroscopie atomique de proprietes nucleaires d'isotopes de francium et de cesium  

Energy Technology Data Exchange (ETDEWEB)

This work is based on the study of cesium ({sup 118,146}Cs) and francium ({sup 207-213}Fr,{sup 220-228}Fr) isotopes by hyperfine atomic spectroscopy and on the interpretation of these results from the nuclear physics point of view. The measured nuclear quantities are: the spin, the magnetic moment, the electric quadrupole moment and the mean square charge radius. The experimental method which is based on hyperfine optical pumping with a tunable laser, followed by magnetic analysis of the atoms is described in the first part. Results related to atomic physics are also presented. In the second part, these data are interpreted in the framework of nuclear models. The deformation of light cesium isomers are compared to values obtained from a theoretical self-consistent calculation. Heavy francium isotopes are situated in an area where the existence of static octupole deformations have been predicted. The odd-even staggering ...

1986-04-15