WorldWideScience
1

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation ...

1985-08-01

2

A preliminary design for a one GHz NMR spectrometer magnet  

International Nuclear Information System (INIS)

The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.

1993-09-20

3

Magnetic liquefier for hydrogen  

Energy Technology Data Exchange (ETDEWEB)

This document summarizes work done at the Astronautics Technology Center of the Astronautics Corporation of America (ACA) in Phase 1 of a four phase program leading to the development of a magnetic liquefier for hydrogen. The project involves the design, fabrication, installation, and operation of a hydrogen liquefier providing significantly reduced capital and operating costs, compared to present liquefiers. To achieve this goal, magnetic refrigeration, a recently developed, highly efficient refrigeration technology, will be used for the liquefaction process. Phase 1 project tasks included liquefier conceptual design and analysis, preliminary design of promising configurations, design selection, and detailed design of the selected design. Fabrication drawings and vendor specifications for the selected design were completed during detailed design. The design of ...

1992-12-31

4

Magnetic refrigeration: the promise and the problems  

Energy Technology Data Exchange (ETDEWEB)

Magnetic refrigeration uses the temperature- and field-dependence of the entropy of some magnetic materials to accomplish cooling. Because of the intrinsically high efficiency of the magnetization and demagnetization process and because of the potential for excellent heat transfer between solids and fluids, magnetic refrigerators promise to have higher efficiency than existing gas-cycle refrigerators. Many ground-based and space-based applications could benefit significantly from the cost savings implied by higher efficiency. Other attributes of these devices are high reliability and low volume and mass per unit cooling power. The development of these refrigerators is underway at several places around the world, including the Los Alamos National Laboratory. The progress to date has been encouraging but some problems have ...

1984-01-01

5

Development of large-capacity refrigeration at 1.8 K for the Large Hadron Collider at CERN  

CERN Document Server

CERN, the European Laboratory for Particle Physics, is working towards the construction of the Large Hadron Collider (LHC), a high-energy, high-luminosity particle accelerator and collider [1] of 26.7 km circumference, due to start producing frontier physics, by bringing into collision intense proton and ion beams with centre-of-mass energies in the TeV-per-constituent range, at the beginning of the next century. The key technology for achieving this ambitious scientific goal at economically acceptable cost is the use of high-field superconducting magnets using Nb-Ti conductor operating in superfluid helium [2]. To maintain the some 25 km of bending and focusing magnets at their operating temperature of 1.9 K, the LHC cryogenic system will have to produce an unprecedented total refrigeration capacity of about 20 kW at 1.8 K, in eight cryogenic plants distributed around the machine ...

1996-01-01

6

Active magnetic regenerator  

Energy Technology Data Exchange (ETDEWEB)

The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.

1982-01-01

7

Investigation and improvement of ejector refrigeration system using computational fluid dynamics technique  

Energy Technology Data Exchange (ETDEWEB)

Ejector refrigeration systems are usually designed to utilize low grade energy for driving the cycle. They also have low maintenance cost because they operate without a compressor. Mainly, the ejector performance directly affects the refrigerating performance. Therefore, an investigation on the characteristics and an efficient design of the ejector are important to improve ejector refrigeration systems. In this study, the computational fluid dynamics (CFD) code, FLUENT, is employed to predict the flow phenomena and performance of CPM and CMA steam ejectors. The ejector refrigeration system, using water as the working fluid, is operated at 120-140 C boiler temperature and 5-15 C evaporator temperature. CFD can predict ejector performance very well and reveal the effect of operating conditions on an effective area that is directly related to ...

2007-09-15

8

Presentations from 2nd Cryogenic Operations Workshop (CRYO 2006) , May 9-11, 2006, Menlo Park, California  

Science.gov (United States)

This workshop covered the latest practical engineering and operational management applications and techniques that have been found to enhance operational costs, reliability, and flexibility, with topics such as establishing the optimal refrigeration design cycle and operating design points; utility management; manpower scheduling; plant control philosophy and automation; short and long term maintenance scheduling; refrigerant loss detection and control; system contamination; component reliability; and equipment technical performance issues.

2006-11-10

9

Energy saver A-sector power test results  

Energy Technology Data Exchange (ETDEWEB)

The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied by three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.

1982-09-15

10

Nomographs for the optimum solar pond driven LiBr/ZnBr sub 2 /CH sub 3 OH absorption-refrigeration system  

Energy Technology Data Exchange (ETDEWEB)

The paper presents a procedure for the calculation of an absorption-refrigeration plant that uses an LiBr/ZnBr{sub 2}/CH{sub 3}OH solution and is driven throughout the year by heat received from a solar pond. The calculations for the solar pond are based on a finite-difference solution of the transient heat conduction differential equation during the year, and the operation of the refrigeration unit is simulated by the use of functions describing the thermodynamic behaviour of the working medium. On the basis of the procedure devised, correlations and nomographs are developed that describe the seasonally optimum operation of the proposed composite system. The nomographs may be employed for a first estimation in the design of such systems. (Author).

1992-07-01

11

Solar-powered cooling systems: Technical and economic analysis on industrial refrigeration and air-conditioning applications  

British Library Electronic Table of Contents (United Kingdom)

In the last years, the growing demand for air conditioning has caused a significant increase in demand for primary energy resources. Solar-powered cooling is one of the technologies which allows to obtain, by using the renewable solar source, an important energy saving compared to traditional air conditioning plants. The paper describes different technical installations for solar cooling, their way of operation, advantages and limits. The objective of the present study has been to analyze the technical and economic feasibility of solar absorption cooling systems, designed for two different application fields: industrial refrigeration and air conditioning. The possibility to replace or integrate the existing plants is studied, by considering the refrigeration requirements of a company, whic...

2009-01-01

12

Design and performance of a solar-powered air-conditioning system in a green building  

Energy Technology Data Exchange (ETDEWEB)

A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the solar-powered ...

2008-05-15

13

Upgrade of X-ray Magnetic Diffraction Experimental System and Its Application to Ferromagnetic Material  

International Nuclear Information System (INIS)

We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to ...

2007-01-19

14

Progress of magnetic-suspension systems and magnetic bearings in the USSR  

International Nuclear Information System (INIS)

This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.

1992-05-01

15

Venus surface power and cooling systems  

British Library Electronic Table of Contents (United Kingdom)

A mission to the surface of Venus would have high scientific value, but most electronic devices and sensors cannot operate at the 450degreeC ambient surface temperature of Venus. Power and cooling systems were analyzed for Venus surface operation. A radioisotope power and cooling system was designed to provide electrical power for a probe operating on the surface of Venus. For a mission duration of substantial length, the use of thermal mass to maintain an operable temperature range is likely impractical, and active refrigeration may be required to keep components at a temperature below ambient. Due to the high thermal convection of the high-density atmosphere, the heat rejection temperature was assumed to be at a 500degreeC radiator temperature, 50degreeC above ambient. The radioisotope S...

2007-01-01

16

Twenty Years of Tevatron Operation  

Energy Technology Data Exchange (ETDEWEB)

The superconducting Tevatron accelerator at Fermi National Accelerator Laboratory (Fermilab) has surpassed twenty years of operation. The Tevatron is still the highest energy particle accelerator in the world and will remain so until the commissioning of the LHC in Europe later this decade. The Tevatron has operated in a Fixed Target mode, accelerating a proton beam into stationary targets/detectors, as well as a Colliding Beam mode, continuously colliding counter rotating beams of protons and antiprotons. Upon completion, the Tevatron cryogenic system became the world's largest helium refrigeration system. In 1993, the Tevatron cryogenic system was given the designation of International Historic Mechanical Engineering Landmark by the American Society of Mechanical Engineers. The operational history, experiences and statistics of the Tevatron, with an emphasis on the cryogenic system, is ...

2004-07-15

17

LUCIFER, a potentially background-free approach to the search for neutrinoless double beta decay  

British Library Electronic Table of Contents (United Kingdom)

LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.

2011-01-01

18

Cardiac arrhythmia in refrigerator repairmen exposed to fluorocarbons.  

UK PubMed Central (United Kingdom)

A field study of 89 refrigerator repairmen was carried out to ascertain whether occupational exposure to fluorocarbons induces cardiac arrhythmia. The concentrations of fluorocarbons in the breathing...Full Text Available

1990-03-01

19

An investigation into flow regimes for two-phase helium flow  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron accelerator at Fermilab incorporates long two-phase helium passages. During magnet design, the generalized flow map of Baker was used to predict homogeneous flow. Longer than expected magnet time constants led to this investigation. The importance of predicting the flow regime has been amplified with the advent of non-horizontal accelerator designs. A test setup was constructed at Fermilab to investigate two-phase helium flow regimes for conditions practical in accelerator designs. The setup consisted of a standard Tevatron satellite refrigerator, subcooling dewar, heater, 35 m long transfer line, and a specialized end box. A knife blade on the midplane of the transfer line diverted the flow from the upper and lower halves of the pipe to separate vessels in the end box. The amount of liquid above and below the plane was measured at various total mass flow rates and liquid percentages. The results show that ...

1987-10-01

20

ADVANCED UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE  

Energy Technology Data Exchange (ETDEWEB)

Limited demand and high cost has prevented the construction of hard rock caverns in this country for a number of years. The storage of natural gas in mined caverns may prove technically feasible if the geology of the targeted market area is suitable; and economically feasible if the cost and convenience of service is competitive with alternative available storage methods for peak supply requirements. It is believed that mined cavern storage can provide the advantages of high delivery rates and multiple fill-withdrawal cycles in areas where salt cavern storage is not possible. In this research project, PB-KBB merged advanced mining technologies and gas refrigeration techniques to develop conceptual designs and cost estimates to demonstrate the commercialization potential of the storage of refrigerated natural gas in hard rock caverns. Five regions of the U.S.A. were studied for underground storage development and PB-KBB reviewed the literature ...

1998-09-01

22

A progress for the health of south countries. The solar refrigerator; Un progres pour la sante dans les pays du Sud. Le refrigerateur solaire  

Energy Technology Data Exchange (ETDEWEB)

In order to conserve vaccines in hot countries a solar refrigerator has been made by a French university. It is a photothermal refrigerator without batteries. It uses two gases: ammonia and calcium chloride. The refrigerator is autonomous and can work eleven days without sun. (N.C.)

1998-05-01

23

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These ...

2009-10-19

24

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

25

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

26

Visualization and void fraction measurements of refrigerant flow in a refrigerator by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)

2000-07-01

27

Correlation between Magnetic Field Quality and mechanical components of the Large Hadron Collider Main Dipoles  

CERN Document Server

The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.

2006-01-01

28

Design, Performance and Series Production of Superconducting Trim Quadrupoles for the Large Hadron Collider  

CERN Document Server

The Large Hadron Collider (LHC) will be equipped with several thousands of superconducting corrector magnets. Among the largest ones are the superconducting trim quadrupoles (MQTL). These twin-aperture magnets with a total mass of up to 1700 kg have a nominal gradient of 129 T/m at 1.9 K and a magnetic length of 1.3 m. Sixty MQTL are required for the LHC, 36 operating at 1.9 K in and 24 operating at 4.5 K. The paper describes the design features, and reports the measured quench performance and magnetic field quality of the production magnets. The MQTL magnet production is shared between CERN and industry. This sharing is simplified due to the modular construction, common to all twin-aperture correctors.

2006-01-01

29

Study of solution for issues of an optimum operating plan in heat storing system; Chikunetsu system ni okeru saiteki un`yo keikaku mondai no kaiho ni taisuru ichikosatsu  

Energy Technology Data Exchange (ETDEWEB)

An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating cost compared with the latter. A case where the operating cost of the resolving ...

1996-02-01

30

Preliminary Calculations of the Radiation Damage of the Permanent Magnets for TRADE (TRiga Accelerator Driven Experiment)  

CERN Document Server

Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part ...

2002-01-01

31

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC ...

1980-03-01

32

Effect of magnet sorting using a simple resonance cancellation method on the RMS orbit distortion at the APS injector synchrotron  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.

1993-07-01

33

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

34

Methods and instruments for nondestructive testing of the anisotropy of the magnetic properties of ferromagnetic sheet materials (review)  

Energy Technology Data Exchange (ETDEWEB)

This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.

1995-04-01

35

Solar-powered refrigerator unit with solar module and transport equipment as stand-alone compact system. Solarkuehlgeraet mit Solarmodul und Transportvorrichtung als autonomes Kompaktsystem  

Energy Technology Data Exchange (ETDEWEB)

A compact and energy independent solar-powered refrigeration unit was to be developed to store and transport small quantities of high-quality commodities needing refrigeration. This unit comprises the following matched components: thermo-electrical refrigerator unit, solar generator and transport equipment. The solar generator is a specially developed panel with 36 cells. This unit may best be used in human medicine, veterinary medicine, environmental protection analysis, laboratories and leisure time activities. (BWI)

1994-01-01

36

A b s t r a c t Vo l u m e  

Wastenet

deodorants and sportswear and silver in washing ma- chines, refrigerators, health care products,

37

Utilization of cold in LNG baseload and peakshaving plants  

Science.gov (United States)

This report presents the results of a survey of the uses of the refrigeration available from vaporizing liquefied natural gas. The major emphasis of the study is on peakshaving plants, which liquefy and regasify domestic gas; the minor emphasis is on base-load terminals, which gasify imported LNG continuously. There are 54 full-scale LNG peakshaving plants in the US and several others under construction. The US has three operating base-load import terminals. One more is under construction and several more large terminals have been proposed. There are at least 12 foreign base-load import terminals in operation, and more are under construction or are proposed. The report presents a survey of operating conditions for about 15 large domestic peakshaving plants. It also presents published design data for the existing US import terminals, for the major proposed import terminals, and for the major overseas ...

1979-10-15

38

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

39

LHC Magnet Tests Operational Techniques and Empowerment for Successful Completion  

CERN Document Server

The LHC magnet tests operation team developed various innovative techniques, particularly since early 2004, to complete the superconductor magnet tests by Feb. 2007. Overall and cryogenic priority handling, rapid on-bench thermal cycling, rule-based goodness evaluation on round-the-clock basis, multiple, mashed web systems are some of these techniques applied with rigour for successful tests completion in time. This paper highlights these operation empowerment tools which had a pivotal role for success. A priority handling method was put in place to enable maximum throughput from twelve test benches, having many different constraints. For the cryogenics infrastructure, it implied judicious allocation of limited resources to the benches. Rapid On-Bench Thermal Cycle was a key strategy to accelerate magnets tests throughput, saving time and simplifying logistics. First level ...

2007-01-01

40

Design and experimental results on a terawatt magnetically controlled plasma opening switch  

Energy Technology Data Exchange (ETDEWEB)

The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at ...

1998-05-01

41

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The ...

1995-12-31

42

Industrial production of RHIC magnets  

Energy Technology Data Exchange (ETDEWEB)

RHIC 8 cm aperture dipole magnets and quadrupole cold masses are being built for Brookhaven National Laboratory (BNL) by Northrop Grumman Corporation at a production rate of one dipole magnet and two quadrupole cold masses per day. This work was preceded by a lengthy Technology Transfer effort which is described elsewhere. This paper describes the tooling which is being used for the construction effort, the production operations at each workstation, and also the use of trend plots of critical construction parameters as a tool for monitoring performance in production. A report on the improvements to production labor since the start of the programs is also provided. The magnet and cold mass designs, and magnetic test results are described in more detail in a separate paper.

1996-07-01

43

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower ...

1993-06-01

44

Energy efficient fuzzy based combined variable refrigerant volume and variable air volume air conditioning system for buildings  

Energy Technology Data Exchange (ETDEWEB)

Energy conservative building design has triggered greater interests in developing flexible and sophisticated air conditioning systems capable of achieving enhanced energy-savings potential without sacrificing the desired thermal comfort and indoor air quality (IAQ). This research work greatly aimed at achieving enhanced energy conservation, good thermal comfort and better IAQ for space conditioning with the application of combined variable refrigerant volume (VRV) and variable air volume (VAV) air conditioning (A/C) systems. Experimental investigation on the proposed combined air conditioning system with the application of intelligent fuzzy logic controller was performed for summer and winter climatic conditions to substantiate the energy-savings capability. The proposed system experimentally analyzed under fixed ventilation, demand controlled ventilation (DCV) and combined DCV and economizer cycle (EC) ventilation techniques effectively conserved 44% and 63% of ...

2010-04-15

45

Spontaneous radiation of an electron beam in a free-electron laser with a quadrupole wiggler  

Energy Technology Data Exchange (ETDEWEB)

A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.

1986-09-01

46

Comments on open-ended magnetic systems for fusion  

Energy Technology Data Exchange (ETDEWEB)

Differentiating characteristics of magnetic confinement systems having externally generated magnetic fields that are open'' are listed and discussed in the light of their several potential advantages for fusion power systems. It is pointed out that at this stage of fusion research high-Q'' (as deduced from long energy confinement times) is not necessarily the most relevant criterion by which to judge the potential of alternate fusion approaches for the economic generation of fusion power. An example is given of a hypothetical open-geometry fusion power system where low-Q operation is essential to meeting one of its main objectives (low neutron power flux).

1990-09-24

47

Applications of Magnetic PsiDO Techniques to Space-adiabatic Perturbation Theory  

CERN Document Server

In this review, we show how advances in the theory of magnetic pseudodifferential operators (magnetic $\\Psi$DO) can be put to good use in space-adiabatic perturbation theory (SAPT). As a particular example, we extend results of [PST03] to a more general class of magnetic fields: we consider a single particle moving in a periodic potential which is subjectd to a weak and slowly-varying electromagnetic field. In addition to the semiclassical parameter $\\eps \\ll 1$ which quantifies the separation of spatial scales, we explore the influence of additional parameters that allow us to selectively switch off the magnetic field. We find that even in the case of magnetic fields with components in $C_b^{\\infty}(\\R^d)$, e. g. for constant magnetic fields, the results of Panati, Spohn and Teufel hold, i.e. to each isolated family of Bloch bands, ...

2010-01-01

48

Dimensional metrology and positioning operations: basics for a spatial layout analysis of measurement systems  

CERN Document Server

Dimensional metrology and positioning operations are used in many fields of particle accelerator projects. This lecture gives the basic tools to designers in the field of measure by analysing the spatial layout of measurement systems since it is central to dimensional metrology as well as positioning operations. In a second part, a case study dedicated to a synchrotron storage ring is proposed from the detection of the magnetic centre of quadrupoles to the orbit definition of the ring.

2010-01-01

49

Demonstration and Evaluation of Magnetic Descalers.  

Science.gov (United States)

Mineral scale formation in water distribution piping impedes flow, resulting in pressure and volume reduction and increasing operational costs. Chemical cleaning is both costly and time consuming, and there are health concerns when chemically cleaning pot...

2001-01-01

50

Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows  

Energy Technology Data Exchange (ETDEWEB)

Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture interphase is accounted for by using the stagnant film model, and closure relations ...

1995-01-01

51

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...

2009-09-14

52

Resistive cryogenic cable economic-viability evaluation. Final report, Volume I  

Energy Technology Data Exchange (ETDEWEB)

This report presents a reassessment of the design of Resistive Cryogenic Cable Systems with regard to dielectric material selection, thermal insulation selection, conductor design, and refrigeration subsystem design. An algorithm using test data generated as part of the program and available from the literature was developed and used to assess the driving parameters for system cost analysis. The results of this cost sensitivity analysis are presented. An electric utility, Public Service Electric and Gas of New Jersey (PSE and G), performed an economic viability evaluation comparing two selected Resistive Cryogenic Cable Systems to a conventional cable system (high pressure oil-filled). The comparison was made for a 35-mile network application on the PSE and G transmission system scheduled to be placed in service in 1995. Consideration was given to equipment capital, installation, and operating costs. It was concluded that a Multilayer Vacuum ...

1980-03-31

53

High-efficiency pump for space helium transfer. Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

A centrifugal pump was developed for the efficient and reliable transfer of liquid helium in space. The pump can be used to refill cryostats on orbiting satellites which use liquid helium for refrigeration at extremely low temperatures. The pump meets the head and flow requirements of on-orbit helium transfer: a flow rate of 800 L/hr at a head of 128 J/kg. The overall pump efficiency at the design point is 0.45. The design head and flow requirements are met with zero net positive suction head, which is the condition in an orbiting helium supply Dewar. The mass transfer efficiency calculated for a space transfer operation is 0.99. Steel ball bearings are used with gas fiber-reinforced teflon retainers to provide solid lubrication. These bearings have demonstrated the longest life in liquid helium endurance tests under simulated pumping conditions. Technology developed in the project also has application for liquid helium circulation in ...

1991-12-01

54

Effects of microwaves on cell survival at elevated temperatures  

Energy Technology Data Exchange (ETDEWEB)

Since microwaves are used in human cancer therapy, information on specific biological effects of microwaves at elevated temperatures is important. To help supply this information, we exposed mammalian cells (CHO) and bacteria (Serratia marcescens) to hyperthermal temperatures (43, 44, and 45/sup o/C for CHO and 48, 49, and 50/sup o/C for the bacteria) with and without microwave irradiation. Temperature control was maintained by a refrigeration-reheat system and high-velocity water recirculation. The 2450-MHz microwave source was operated in a pulsed mode with power density up to 500 mW/cm/sup 2/. As expected, the survival curve slopes for both cell types increased rapidly with temperature, doubling for each degree Celsius. Microwave irradiation produced no significant change in extrapolation number for either cell type. However, survival curves of CHO cells which received microwaves were steeper by a factor of 1.25 than their sham-irradiated ...

1981-12-01

55

Application of neutron radiography to a diagnosis of refrigerator  

International Nuclear Information System (INIS)

A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).

1996-07-01

56

REALISTIC NON-LINEAR MODEL AND FIELD QUALITY ANALYSIS IN RHIC INTERACTION REGIONS.  

Energy Technology Data Exchange (ETDEWEB)

The existence of multipole components in the dipole and quadrupole magnets is one of the factors limiting the beam stability in the RHIC operations. So, a realistic non-linear model is crucial for understanding the beam behavior and to achieve the ultimate performance in RHIC. A procedure is developed to build a non-linear model using the available multipole component data obtained from measurements of RHIC magnets. We first discuss the measurements performed at different stages of manufacturing of the magnets in relation to their current state in RHIC. We then describe the procedure to implement these measurement data into tracking models, including the implementation of the multipole feed down effect due to the beam orbit offset from the magnet center. Finally, the field quality analysis in the RHIC interaction regions (IR) is presented.

2007-06-25

57

Development of high-field STM for 18 T cryocooled superconducting magnet  

International Nuclear Information System (INIS)

To study the nanoscale electronic order in strongly correlated electron systems and vortex states in high-Tc superconductors in high magnetic fields, we have developed scanning tunneling microscopy (STM) for the 18 T cryocooled superconducting magnet (18T-CSM). The test results of the STM operation in the 18T-CSM at room temperature indicate that our STM has a good atomic resolution up to 18 T when we use the nonmagnetic vibration-isolation table which reduce the vibration noise from the cryocoolers of the 18T-CSM. In this paper, we report on the design of the high-field STM system for large-scale magnets and its performance.

2009-02-01

58

On-line nuclear orientation  

Energy Technology Data Exchange (ETDEWEB)

This report discusses: shape coexistence in {sup 184}Pt; nuclear structure of {sup 187}Ir; g-factors of excited states; OLNO-2; and refrigerator development.

1992-01-01

59

On-line nuclear orientation  

International Nuclear Information System (INIS)

This report discusses: shape coexistence in "1"8"4Pt; nuclear structure of "1"8"7Ir; g-factors of excited states; OLNO-2; and refrigerator development.

60

Design and optimization of thermoacoustic devices  

International Nuclear Information System (INIS)

Thermoacoustics deals with the conversion of heat energy into sound energy and vice versa. It is a new and emerging technology which has a strong potential towards the development of sustainable and renewable energy systems by utilizing waste heat or solar energy. Although simple to fabricate, the designing of thermoacoustic devices is very challenging. In the present study, a comprehensive design and optimization algorithm is developed for designing thermoacoustic devices. The unique feature of the present algorithm is its ability to design thermoacoustically-driven thermoacoustic refrigerators that can serve as sustainable refrigeration systems. In addition, new features based on the energy balance are also included to design individual thermoacoustic engines and acoustically-driven thermoacoustic refrigerators. As a case study, a thermoacoustically-driven thermoacoustic refrigerator has been designed ...

2008-12-01

61

A modular and extensible data acquisition and control system for testing superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into operation. This system utilizes a modular approach that provides both ...

2001-07-20

63

Desiccant cooling: parametric energy study  

Energy Technology Data Exchange (ETDEWEB)

Desiccants have been used in many applications to provide dehumidification. This paper describes an application of desiccants which provide both dehumidification and sensible cooling, with little or no use of conventional vapour-compression refrigeration plant. Through a parametric study, the energy consumption and costs of a desiccant cooling system are compared with those of a conventional vapour-compression refrigeration-based air-conditioning system. (author)

1998-12-31

64

Design and operating experience of a 40 MW, highly-stabilized power supply  

Energy Technology Data Exchange (ETDEWEB)

Four 10 MW, highly-stabilized power supply modules have been installed at the National High Magnetic Field Laboratory in Tallahassee, FL, to energize water-cooled, resistive, high-field research magnets. The power supply modules achieve a long term current stability if 10 ppM over a 12 h period with a short term ripple and noise variation of <10 ppM over a time period of one cycle. The power supply modules can operate independently, feeding four separate magnets, or two, three or four modules can operate in parallel. Each power supply module consists of a 12.5 kV vacuum circuit breaker, two three-winding, step-down transformers, a 24-pulse rectifier with interphase reactors, and a passive and an active filter. Two different transformer tap settings allow rated dc supply output voltages of 400 and 500 V. The rated current of a supply module is 17 kA and each supply module has a ...

1995-07-01

65

An implicit curve-fitting method for fast calculation of thermal properties of pure and mixed refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Calculations of refrigerant thermal properties are desired to be very fast and stable in cases of simulation of refrigeration system, etc. The traditional method based on equation of state cannot meet such requirement because of unavoidable iterations in calculation. In this paper, a new calculation method for refrigerant thermal properties is presented. Low order implicit polynomial equations are got by using curve-fitting method at first, and then explicit formulae for calculating refrigerant thermal properties quickly are obtained by getting the analytical solution of these implicit equations. Explicit fast calculation formulae for thermal properties of R22 and R407C, covering the saturated temperature of -60{approx}80 {sup o}C and superheat of 0-65 {sup o}C, are presented as examples. The calculation speeds of the formulae of R22 are about 140 times faster than those of REFPROP 6.01 while the ...

2005-09-01

66

The Bevatron liquid nitrogen circulation system  

Science.gov (United States)

A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.

1987-03-01

67

Operation principle of microsecond plasma opening switches  

International Nuclear Information System (INIS)

Closing and breaking of current in microsecond megaampere plasma opening switches are considered. Conductivity current scaling in the switch due to plasma acceleration by a magnetic piston is discussed and compared with experimental data. Two ways of determining the width of a current channel are taken up. This channel results from the diffusion of the magnetic field in the plane of the piston followed by the convective ejection of the field frozen in the accelerated plasma flow behind the shock wave into the bridge. Based on experimental data, a scaling law for the voltage on the switch according to the switch parameters is derived. The problem of reverse closing, which limits the efficiency of storage energy extraction into the load, is considered

2009-01-01

68

Dynamics of a H(n) atom in time-dependent electric and magnetic fields  

International Nuclear Information System (INIS)

The symmetry properties of the Coulomb potential allow for a dynamical spin-1/2 description of any fixed n level of a hydrogenlike atom in a time-dependent sufficiently weak electric and/or magnetic field. An explicit expression for the time dependence of the l,m amplitudes pertaining to a general n level is derived. The derivation follows on purely algebraic operations. Based on the derivation, we give analytical n-independent solutions to established and proposed schemes for driving the atom into a high angular-momentum state.

2002-05-01

69

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a ...

1346-01-01

70

The impact of solar flares and magnetic storms on humans  

International Nuclear Information System (INIS)

Three classes of solar emanations, namely, photon radiation from solar flares, solar energetic particles, and inhomogeneities in the solar wind that drive magnetic storms, are examined, and their effects on humans and technological systems are discussed. Solar flares may disrupt radio communications in the HF and VLF ranges. Energetic particles pose a special hazard at low-earth orbit and above, where they can penetrate barriers such as spacesuits and aluminum and destroy cells and solid state electronics. Energetic solar particles also influence terrestrial radio waves propagating through polar regions. Magnetic storms may disturb the operation of navigation instruments, power lines and pipelines, and satellites; they give rise to ionospheric storms which affect radio communication at all latitudes. There is also a growing body of evidence that changes in the geomagnetic field affect biological systems. 3 refs.

71

A soft x-ray free electron laser (FEL) using a two-beam elliptical pill-box wake-field cavity  

International Nuclear Information System (INIS)

Stimulated bremsstrahlung in an undulating electric field in the lasing beam direction (electric wiggler) was shown to be possible from the quantum- mechanical viewpoint. Herein, this possibility is scrutinized from the viewpoint of classical electrodynamics. It is found that if stimulated bremsstrahlung in a transverse undulating magnetic field (magnetic wiggler) occurs, stimulated bremsstrahlung in the electric wiggler must also occur. We further show that a free electron laser (FEL) using a magnetic wiggler to provide a catalyzer field for stimulated bremsstrahlung cannot serve as a practical FEL operating in the soft x-ray region from both theoretical and experimental viewpoints. On the other hand, the authors demonstrate that the FEL using a traveling wake field in a two-beam elliptical pill-box cavity is well suited as a source of coherent radiation in the soft x-ray region.

1988-01-14

72

A principle of charged particle trapping by RF electromagnetic field in the spherical cavity  

Energy Technology Data Exchange (ETDEWEB)

A new principle of particle trapping in the simple spherical cavity using both electric and magnetic components of radiofrequency electromagnetic field is proposed. The electric component of H {sub 12} oscillating mode drives the fast particle oscillations, while the magnetic component synchronously bends the trajectories to the cavity center. A specially developed theory of particle stability predicts dense and energetic electron cluster in the trap. Numerical simulations of particle dynamics in the complete electromagnetic field taking into account both space charge and particle-induced magnetic field are in good agreement with the analytic results, giving a density of 2.6*10{sup 1} electrons/cm{sup 3} and an average kinetic energy of around 30 keV at an operating frequency of 3 GHz. Being used at lower frequency, spherical cavity can trap protons and heavier ions too, but with lower density and ...

2005-11-21

73

The metrology of the LHC project: what news?  

Energy Technology Data Exchange (ETDEWEB)

The Large Hadron Collider (LHC), under construction at CERN, uses superconducting magnets operating at a temperature of 1.9 K to guide the circulating particles. A specific feature of the main magnets (dipoles and quadrupoles) is the two-in-one design with two magnetic channels in one common retaining structure. Indeed, the accelerator is made of two rings, mechanically linked, that have to be simultaneously aligned during the installation in the already existing LEP tunnel. The assembly tolerances of the LHC main magnets have been reconsidered to take into account the tight constraints on geometry. The dipoles are bent to follow closely the curvature of the circulating particles and to make a larger mechanical aperture available for the circulating particles. In order to minimise the geometrical errors the dipole assembly procedure is assisted by high precision survey measurements ...

1999-07-01

74

Post-CHF Heat Transfer characteristics in one rod bundle geometry  

Energy Technology Data Exchange (ETDEWEB)

In the present paper, experimental study of forced convection boiling were performed to investigate the post-CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100-600 kg/m{sup 2}s, and inlet temperatures of 25-51 .deg. C. The parametric trend of the post-CHF data was well consistent with previous studies. The two phase flow regime in tube flow occurring downstream of the CHF has been called post-CHF, dispersed flow, liquid-deficient flow, mist flow and film boiling. This regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. This regime has a considerable importance in the areas of light water reactor(LWR) accident analysis and other film boiling applications. The post-CHF region occurs by design in heat exchangers operating ...

2006-07-01

75

Post-CHF Heat Transfer characteristics in one rod bundle geometry  

International Nuclear Information System (INIS)

In the present paper, experimental study of forced convection boiling were performed to investigate the post-CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100-600 kg/m2s, and inlet temperatures of 25-51 .deg. C. The parametric trend of the post-CHF data was well consistent with previous studies. The two phase flow regime in tube flow occurring downstream of the CHF has been called post-CHF, dispersed flow, liquid-deficient flow, mist flow and film boiling. This regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. This regime has a considerable importance in the areas of light water reactor(LWR) accident analysis and other film boiling applications. The post-CHF region occurs by design in heat exchangers operating in the ...

2006-11-02

76

EHD enhancement of pool and in-tube boiling of alternate refrigerants. Final report, 15 January 1993--15 June 1993  

Energy Technology Data Exchange (ETDEWEB)

The Electrohydrodynamic (EHD) is an active heat transfer augmentation technique which utilizes the effect of secondary motions generated through the application of an electrostatic potential to a dielectric fluid. Net result is better momentum and heat transfer between the fluid and the heat transfer wall through destabilization of the thermal boundary layer and better mixing of the fluid adjacent to the heat transfer surface. EHD enhancement of refrigerant/refrigerant oil mixtures heat transfer using the Electrohydrodynamic (EHD) technique is the subject of a three-year experimental investigation in a project funded by the US Department of Energy, effective June 1, 1993. For the interim period between November 1992 and June 1993 when the DOE funds became available, the Air-Conditioning and Refrigeration Technology Institute (ARTI) provided partial funding for our EHD research program with the aim of accomplishing three major tasks: (1) conduct ...

1993-08-01

78

Extension of the implicit curve-fitting method for fast calculation of thermodynamic properties of refrigerants in supercritical region  

Energy Technology Data Exchange (ETDEWEB)

The implicit curve-fitting method has been used for fast and stable calculations of thermodynamic properties of subcritical refrigerants, and it has to use the saturated liquid or vapor state as the reference state. In order to extend the application range of this method in supercritical region, an isothermal state in the supercritical region is used as the reference state, and the implicit equations for supercritical refrigerants in this state and out of this state are established, respectively. The new calculation method can be used in the entire supercritical region. With the new method, thermodynamic properties of supercritical CO{sub 2} and R410A are predicted and compared with REFPROP 8. It shows that the total mean relative deviations of the fast calculation formulae from REFPROP 8 are less than 1%, while the mean calculation speeds of the fast calculation formulae are more than 100 times faster than those of REFPROP 8. (author)

2009-11-15

79

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research ...

80

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high ...

2008-06-01

81

Magnetic nanoparticle detection using nano-SQUID sensors  

International Nuclear Information System (INIS)

We demonstrate detection of a single core-shell magnetite-silica nanoparticle (outer diameter #approx#120 nm, moment #approx#10"4#mu#_B) using an Nb dc superconducting quantum interference device (SQUID) with the loop size of 350 nm operational at T < 10 K. The system noise was minimized down to 0.2 #mu##PHI#_0 Hz"-"1"/"2 using a cryogenic SQUID series array pre-amplifier. Initial measurements of an individual magnetic nanoparticle were performed and a clear change of the noise spectra of the nano-SQUID was detected at low frequencies in the presence of the nanoparticle. Similar behaviour was confirmed with an FePt nanoparticle with a larger magnetic moment (diameter #approx#150 nm, moment #approx#10"6#mu#_B). Thus, we demonstrate a magnetic sensor based on a dc nano-SQUID and enabling detection of small moments (potentially down to a few electron spins). Such a sensor is of considerable significance ...

2010-12-01

82

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were presented as color-coded anatomically-mapped ...

83

The future of refrigeration and air conditioning. The master shows in restriction. Expert discussion on the work of the UNEP Technology and Economics Assessment Panel. Zur Zukunft der Kaelte und Klimatechnik. In der Beschraenkung zeigt sich der Meister. Ein Fachgespraech zur Arbeit des UNEP Technology and Economics Assessment Panels  

Energy Technology Data Exchange (ETDEWEB)

On behalf of the United Nations Environment Programme (UNEP) a study has been established by the Refrigeration, Air Conditioning and Heat Pump Technical Options Committee in which famous experts of refrigeration technology compiled facts which allow for a reliable prospect of real possibilities of changing from fluorine hydrogen to ozone innoxious substitutes and substitute technologies. With regard to the organization, a division into 6 committees for the establishment of the study has been made: 1. Refrigeration Options Committee, 2. Foams Options Committee, 3. Solvents, Coatings and Adhesives Options Committee, 4. Aerosols, Sterilants and Miscellaneous Uses Options Committee, 5. Halons Technical Options Committee and 6. Economic Options Committee. (BWI).

1992-09-01

84

On-line nuclear orientation. Progress report, April 1, 1991--March 31, 1992  

Energy Technology Data Exchange (ETDEWEB)

This report discusses: shape coexistence in {sup 184}Pt; nuclear structure of {sup 187}Ir; g-factors of excited states; OLNO-2; and refrigerator development.

1992-06-01

85

Mutagenicity of stemphyltoxin III, a metabolite of Alternaria alternata.  

UK PubMed Central (United Kingdom)

Some common decay organisms of vegetables and ripened fruits are Alternaria species. Even fruits and vegetables kept under refrigeration can be spoiled by Alternaria species because the mold grows at...Full Text Available

1991-01-01

86

Global residential appliance standards  

Energy Technology Data Exchange (ETDEWEB)

In most countries, residential electricity consumption typically ranges from 20% to 40% of total electricity consumption. This energy is used for heating, cooling, refrigeration and other end-uses. Significant energy savings are possible if new appliance purchases are for models with higher efficiency than that of existing models. There are several ways to ensure or encourage such an outcome, for example, appliance rebates, innovative procurement, and minimum efficiency standards. This paper focuses on the latter approach. At the present time, the US is the only country with comprehensive appliance energy efficiency standards. However, many other countries, such as Australia, Canada, the European Community (EC), Japan and Korea, are considering enacting standards. The greatest potential impact of minimum efficiency standards for appliances is in the developing countries (e.g., China and India), where saturations of household appliances are relatively low but ...

1993-03-01

87

Evaluation of energy-conservation technologies for the citrus-processing industry  

Energy Technology Data Exchange (ETDEWEB)

The following manual chapters are outlined and described: overview, boilers, juice evaporators, feed mills, refrigeration, additional energy savings potentials, emerging technologies, optimization of integrated plant energy systems, and economics. (MHR)

1980-01-01

88

The state of the art: Appliances  

Energy Technology Data Exchange (ETDEWEB)

This original volume of the Appliances Atlas includes discussion of residential appliances, commercial refrigeration and cooking, and office equipment. (The residential appliances section has since been updated in the E Source 1994 Residential Appliances Technology Atlas.) The commercial refrigeration section contains details on efficiency opportunities through load reduction and mechanical system improvements, while commercial cooking covers improvements to electric and gas fryers, griddles, ovens, cooktops, broilers, and steam equipment. The office equipment section offers discussion of trends and energy use of computers and their components, imaging technologies, and communication equipment. (Published under the former name, Competitek.)

1990-12-31

89

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

90

Revolutionary news on superconductivity  

Energy Technology Data Exchange (ETDEWEB)

A brief article gives an update on the commercial exploitation of superconductivity by the American Superconductor Corporation. Potential applications include transmission and distribution, motors, magnetic storage systems, current limiters and transport. The company have produced a kilometre long, ''wrappable'' cable capable of carrying thousands of amps when operating at a temperature of below -140[sup o]C. (UK)

1994-09-01

91

Thermal performance of automotive aluminium plate radiator  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to manufacture a wide range of heat exchanger configurations that can help augment heat transfer whilst reducing pressure drops. ...

2005-06-01

92

Flow patterns and heat transfer coefficients in flow-boiling and convective condensation of R22 inside a micro fin of new design  

International Nuclear Information System (INIS)

Saturated flow boiling and convective condensation experiments for oil-free refrigerant R22 been carried out with a micro fin tube of new design and with a smooth tube. Both tube have the same outer diameter of 9.52 mm and are horizontally operated. Two-phase flow pattern data have been obtained in addition of heat transfer coefficient and pressure drops; more-over, adiabatic tests have been also performed in order for flow pattern map to cover even adiabatic flows. Data are for mass fluxes ranging from about 90 to 400 Kg/s m"2. In boiling tests, the nominal saturation temperature is 5 degree C, with inlet quality varying from 0.2 to 0.6 and the quality change ranging from 0.1 to 0.5. In condensation, results are for saturation temperature equal to 35 degree C, with inlet quality between 0.8 and 0.4, and quality change within 0.6 and 0.2. The comparison shows a large heat transfer augmentation with a moderate increment of pressure drops, ...

1998-01-01

93

Adaptation of the low-cost and low-power tactical split Stirling cryogenic cooler for aerospace applications  

Science.gov (United States)

Cryogenic coolers are often used in modern spacecraft in conjunction with sensitive electronics and sensors of military, commercial and scientific instrumentation. The typical space requirements are: power efficiency, low vibration export, proven reliability, ability to survive launch vibration/shock and long-term exposure to space radiation. A long-standing paradigm of exclusively using "space heritage" equipment has become the standard practice for delivering high reliability components. Unfortunately, this conservative "space heritage" practice can result in using outdated, oversized, overweight and overpriced cryogenic coolers and is becoming increasingly unacceptable for space agencies now operating within tough monetary and time constraints. The recent trend in developing mini and micro satellites for relatively inexpensive missions has prompted attempts to adapt leading-edge tactical cryogenic coolers for suitability in the space environment. The primary ...

2011-05-01

94

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, an aluminum target ...

2010-05-01

95

Gamma irradiation in the control of pathogenic bacteria in refrigerated ground chicken meat; Irradiacao gama no controle de bacterias patogenicas em carne de frango refrigerada  

Energy Technology Data Exchange (ETDEWEB)

This work evaluated the effect of gamma radiation on reducing the population of Staphylococcus aureus, Escherichia coli nd Salmonella typhimurium in ground chicken breast stored under refrigeration. The experiment included a control and 4 doses of gamma radiation ( 2.0, 4.0, 6.0 and 8.0 kGy) along with 5 periods of storage under refrigeration ( 1, 7 14, 21 and 28 days). Samples of ground chicken breast were inoculated with Staphylococcus aureus (ATCC 14458), Escherichia coli (ATCC 11105) and Salmonella typhimurium (ATCC 0626), irradiated at temperatures between 4 and 8 deg C and stored under refrigeration (5 deg C) for 28 days. The increased radiation dose and period of storage under refrigeration caused a reduction of Staphylococcus aureus, Escherichia coli and Salmonella typhimurium populations in the ground chicken breast. Mean radiation D values determined for Staphylococcus aureus and Escherichia ...

2000-09-01

96

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

97

[Effects of 50 to 60 Hz and of 20 to 50 kHz magnetic fields on the operation of implanted cardiac pacemakers].  

Science.gov (United States)

The effect of 50 Hz and 60 Hz (frequencies of current distribution) and 20 kHz to 50 kHz (frequencies of induction cooktop) magnetic interference on implanted pacemakers have been assessed with the present generation of device technology. Sixty patients implanted in 1998 and 1999 with dual chamber pacemakers from 9 different manufacturers were monitored with telemetry while passing through, and standing between a system of two coils. They generated a 50 Hz or a 60 Hz magnetic field at 50 microT. Then, patients used a cooktop at different power. The recordings were made with the standard setting of "medically correct" sensing parameters chosen for the patients. Then pacemakers were reprogrammed to the unipolar mode, with the highest atrial (A) and ventricular (V) sensitivity that did not induce muscular inhibition while moving. Between each exposure (50 Hz, 60 Hz or 20 kHz to 50 kHz), the pacemaker programmation was controlled. At the end of the ...

2003-04-01

98

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

100

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

101

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

102

The role of MRI in the diagnosis of recurrent/persistent carpal tunnel syndrome: A radiological and intra-operative correlation  

British Library Electronic Table of Contents (United Kingdom)

MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...

2011-01-01

103

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

104

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

105

World`s longest and fasted inclined mine winder using permanent magnet synchronous motor; Eikyu jishaku doki dendoki wo shiyoshita sekai saicho saikosoku no shako makiage setsubi  

Energy Technology Data Exchange (ETDEWEB)

The latest inclined mine winder started operation in April, 1995 at the Kushiro Mining Station of Taiheiyo Coal Mining Co. A permanent magnet synchronous motor, a cycloconverter, and H{sub {infinity}} control are employed to complete the latest inclined mine winder. The winder is the world`s longest and fastest inclined mine winder, and the torque of the permanent magnet synchronous motor is the largest in the world. A report is made on the driving system placing emphasis on the points considered in the design. The gallery has the length of world`s longest 6,626m and the average gentle inclination of 6 degree. The worker transport car runs at the world`s fastest speed of 420m/min from the mouth to the bottom of the pit, making a round trip in 40 minutes. Speed is adjusted smoothly by the cycloconverter, and the car arrives at the destination safely in a short time due H{sub {infinity}} controlling. By the application of ...

1996-09-30

106

Direct energy conversion for IEC fusion for space applications  

Energy Technology Data Exchange (ETDEWEB)

The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It ...

2000-08-01

107

Cold SQUIDs and hot samples  

Energy Technology Data Exchange (ETDEWEB)

Low transition temperature (low-{Tc}) and high-{Tc} Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-{Tc} superconductors using two low-{Tc} SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise sources, suggesting that the vortices moved as ...

1997-05-01

108

A Wide-Band Electromagnetic Impedance Profiling System forNon-Invasive Subsurface Characterization  

Energy Technology Data Exchange (ETDEWEB)

A non-invasive, wide-band electromagnetic (EM) impedance difference system for shallow subsurface electrical structure characterization in environmental and engineering problems has been developed at the Lawrence Berkeley National Laboratory (LBNL). Electrical parameters of interest are electrical conductivity and dielectric permittivity that are deduced from the impedance difference data. The prototype system includes a magnetic loop transmitter, which operates between 0.1 MHz and 100 MHz, an electrical dipole antenna for observing the electric field, and a loop antenna for measuring the magnetic field.All antennas are mounted on a cart made of non-metallic material for easy movement of the whole array for profiling. Surface EM impedance difference is obtained by taking the difference of the ratios of the electric fields to the magnetic fields at selected frequencies at two different levels. Numerical ...

2004-12-17

109

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

110

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

111

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

112

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

113

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

115

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

116

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

118

H{sup -} ion source using a localized virtual magnetic filter in the plasma electrode: type I LV magnetic filter  

Energy Technology Data Exchange (ETDEWEB)

A new multicusp H{sup -} ion source using a Localized Virtual magnetic filter of type I [Ref.6] in the plasma electrode is investigated. A multipole (MP) arrangement with a spacing of 10 mm of the magnet bars holds an extraction hole, optimizing the efficient production of high H{sup -} current, and at the same time only a small electron component was co-extracted with the H{sup -} ions. The local filter arrangement separates the beam electrons at a low energy. It is shown that the co-extracted total electron current is determined principally by the integrated magnetic field flux (Gcm) of the local filter with an extraction system at a constant extraction voltage. When the value of the Gcm is increased, the total electron component is reduced, while the H{sup -} electrical efficiency had a broad maximum around the optimized value of the Gcm. A thicker plasma electrode should be necessary for sufficient reduction of electron ...

1999-12-01

119

Managing system for mounted parts and spare parts of power source facilities  

Energy Technology Data Exchange (ETDEWEB)

The power source facilities of JT-60 consist of poloidal magnetic coil power source, toroidal magnetic coil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual relating and retrieval by making mounted parts and spare parts into a data base and doing their unified ...

1995-07-01

120

Long-term reliability of amorphous alloy wound core distribution transformers  

Energy Technology Data Exchange (ETDEWEB)

In order to verify long-term reliability of amorphous alloy wound core distribution transformers, accelerated aging tests and field trials used by actual transformers were practiced. As for accelerated aging tests, short-circuit tests were added to imitate mechanical stress in operation on a utility's distribution system. As a result, even after the equivalent of 30 years, which was the normal expected transformer's life, magnetic characteristic was unchanged, so these transformers could be operated. Also, about field trials, two hundred transformers of four kinds were installed on a utility's distribution system to look into no-load characteristics. They were equipped with a mechanism to measure load current, background vibration and lightning surge current, so the influence for magnetic characteristic could be inspected. As a result, remarkable change wasn't seen ...

1994-01-01

121

Refrigeration loads in a freezer due to hot gas defrost and their associated costs  

Energy Technology Data Exchange (ETDEWEB)

The build-up of frost on unit cooler surfaces, if not periodically cleared, will eventually cause impairment of the unit's performance, eventually rendering it useless. Thus it is necessary, in spaces below freezing, to provide an external supply of heat to warm the unit sufficiently to melt the frost and remove it. In large central-plant-type systems the most common method employed for supplying heat is from the high-pressure side of the refrigeration system, referred to as hot gas defrost. Although the heat thus captured for use in melting frost would otherwise be rejected external to the system, the defrosting process is not free of cost. There are significant losses associated with the process the magnitude of which have not heretofore been fully identified. This paper looks at the heat and mass transfer and fluid flow mechanisms involved in the hot gas defrost process in large commercial freezers. It suggests some mathematical models for analysis of ...

1989-01-01

122

Prediction of refrigerant void fraction in horizontal tubes using probabilistic flow regime maps  

Energy Technology Data Exchange (ETDEWEB)

A state of the art review of two-phase void fraction models in smooth horizontal tubes is provided and a probabilistic two-phase flow regime map void fraction model is developed for refrigerants under condensation, adiabatic, and evaporation conditions in smooth, horizontal tubes. Time fraction information from a generalized probabilistic two-phase flow map is used to provide a physically based weighting of void fraction models for different flow regimes. The present model and void fraction models in the literature are compared to data from multiple sources including R11, R12, R134a, R22, R410A refrigerants, 4.26-9.58 mm diameter tubes, mass fluxes from 70 to 900 kg/m{sup 2} s, and a full quality range. The present model has a mean absolute deviation of 3.5% when compared to the collected database. (author)

2008-04-15

123

Separation of variables for the quantum SL(2,R) spin chain  

CERN Document Server

We construct representation of the Separated Variables (SoV) for the quantum SL(2,R) Heisenberg closed spin chain and obtain the integral representation for the eigenfunctions of the model. We calculate explicitly the Sklyanin measure defining the scalar product in the SoV representation and demonstrate that the language of Feynman diagrams is extremely useful in establishing various properties of the model. The kernel of the unitary transformation to the SoV representation is described by the same "pyramid diagram" as appeared before in the SoV representation for the SL(2,C) spin magnet. We argue that this kernel is given by the product of the Baxter Q-operators projected onto a special reference state.

2003-01-01

124

Quantum Computing with an Electron Spin Ensemble  

DEFF Research Database (Denmark)

We propose to encode a register of quantum bits in different collective electron spin wave excitations in a solid medium. Coupling to spins is enabled by locating them in the vicinity of a superconducting transmission line cavity, and making use of their strong collective coupling to the quantized radiation field. The transformation between different spin waves is achieved by applying gradient magnetic fields across the sample, while a Cooper pair box, resonant with the cavity field, may be used to carry out one- and two-qubit gate operations.

2009-01-01

125

In-beam #gamma#-ray spectroscopy of fast beams at the NSCL  

International Nuclear Information System (INIS)

With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.

2004-04-05

126

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

127

HTSC devices fabricated by selective epitaxial growth  

International Nuclear Information System (INIS)

The use of a selective epitaxial growth technique for fabricating YBCO thin-film microstructures is described. No film post-deposition processing is required; hence damage to the structure is minimized. The technique is compatible with a passivation process to protect the structure without exposure to air. The microbridges, Josephson junctions and rf SQUIDs protected by an amorphous YBCO passivation have long lifetime even after severe accelerated aging tests. Rf SQUIDs fabricated by this technique show a significant reduction of low-frequency noise when operating in weak magnetic fields compared with SQUIDs fabricated by the conventional ion beam etching technique. (author)

1999-04-01

128

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...

2009-03-01

129

Thermal loads on tokamak plasma-facing components during normal operation and disruptions  

Energy Technology Data Exchange (ETDEWEB)

Power loadings experienced by tokamak plasma-facing components during normal operation and during off-normal events are discussed. A model for power and particle flow in the tokamak boundary layer is presented and model predictions are compared to infrared measurements of component heating. The inclusion of the full three-dimensional geometry of the components and of the magnetic flux surface is very important in the modeling. Experimental measurements show that misalignment of component armour tile surfaces by only a millimeter can lead to significant localized heating. An application to the design of plasma-facing components for future machines is presented. Finally, thermal loads expected during tokamak disruptions are discussed. The primary problems are surface melting and vaporization due to localized intense heating during the disruption thermal quench and volumetric heating of the component armour and structure due to localised impact of ...

1990-01-01

130

Air conditioning in high rise buildings; conditionnement d'air dans les immeubles de grande hauteur  

Energy Technology Data Exchange (ETDEWEB)

This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; air quality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)

2000-07-01

131

Protocol to the 1994 Co-operation Agreement between The Government of the Islamic Republic of Pakistan and CERN concerning a Special Contribution by Pakistan towards the Construction of the LHC  

CERN Document Server

CERN signed a Co-operation Agreement with the Government of Pakistan in 1994, which was followed in 1997 by a Protocol signed with the Pakistan Atomic Energy Commission (PAEC) concerning CMS magnet supports. CERN and PAEC then signed in 1998 a Memorandum of Understanding for collaboration in the construction of the CMS detector. The participation by Pakistani scientists and engineers in the CERN programme is channelled through the National Centre of Physics (NCP) established at the Quaid-i-Azzam University in Islamabad, under the terms of a 1999 Protocol to the 1994 Co-operation Agreement. The engineering and detector construction work performed under these Agreements has been of high quality, and the Pakistani participation is valued highly by the CMS collaboration. In continuation of this co-operation, Pakistan, represented by PAEC as funding agency, has now proposed to make in-kind contributions to ...

2003-01-01

132

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...

2008-04-15

133

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...

1981-11-11

135

Magnetic braking of the rotation of molecular cloud cores  

International Nuclear Information System (INIS)

We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).

136

LHC magnet alignment  

CERN Document Server

Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.

2007-01-01

137

Test results of TQS03: a LARP shell-based Nb3Sn quadrupole using 108/127 conductor  

Energy Technology Data Exchange (ETDEWEB)

Future insertion quadrupoles with large apertures and high gradients will be required for the Phase II luminosity upgrade (10{sup 35} cm{sup -2}s{sup -1}) of the Large Hadron Collider (LHC). Although improved designs, based on NbTi, are being considered as an intermediate step for the Phase I upgrade, the Nb{sub 3}Sn conductor is presently the best option that meets the ultimate performance goals for both operating field and temperature margin. As part of the development of Nb{sub 3}Sn magnet technology, the LHC Accelerator Research Program (LARP) developed and tested several 1-meter long, 90-mm aperture Nb{sub 3}Sn quadrupoles. The first two series of magnet used OST MJR 54/61 (TQ01 series) and OST RRP 54/61 (TQ02 series) strands. The third series (TQ03) used OST RRP 108/127 conductor. The larger number of sub-elements and the consequent reduction of the effective filament size, together with an increased fraction of ...

2009-09-13

138

The European volcanic ash crisis: Between international and European law | EurActiv  

Wastenet

... Carbon capture and storage Waste Prevention and Recycling EU clean air strategy Environmental liability: Applying the 'polluter pays' principle What goes around ...comes around: Recycling and climate change Behind closed doors: Air quality in buildings Keeping cool with refrigerants: The F-gas review Regions fighting climate ...

139

ORNL `90  

Energy Technology Data Exchange (ETDEWEB)

This overview of research conducted at ORNL in 1991 presents information on the subjects of biology, physics, and the environment. Specific topics include gene mutations in kidney disease, technology assessments in thermonuclear fusion, submarine hunting technology, ozone-safe refrigerants, optical data storage via surface enhanced raman spectroscopy, and waste mitigating microbes. (GHH)

1990-12-31

140

ORNL '90  

Energy Technology Data Exchange (ETDEWEB)

This overview of research conducted at ORNL in 1991 presents information on the subjects of biology, physics, and the environment. Specific topics include gene mutations in kidney disease, technology assessments in thermonuclear fusion, submarine hunting technology, ozone-safe refrigerants, optical data storage via surface enhanced raman spectroscopy, and waste mitigating microbes. (GHH)

1990-01-01

141

Evaluation of synergistic effect in vacuum pack, refrigeration and irradiated treatments of minimally processed cassava; Avaliacao do efeito sinergistico da embalagem a vacuo, irradiacao e refrigeracao da mandioca minimamente processada  

Energy Technology Data Exchange (ETDEWEB)

Cassava is cultivated almost all over the world and it is considered one of the most important nutritious sources of calories in the human diet. Cassava is a viable food against starvation in several poor areas of the world because it is an extremely resistant culture and may reach satisfactory economical yield. We utilized vacuum packed industrialized cassava irradiated with 0,1 kGy, 3kGy and 5kGy and stored under refrigeration for 1, 21, 30 and 50 days. Our objective was to analyse the synergistic effect of vacuum packing, irradiation and refrigeration on the preservation of minimally processed cassava. The samples were analyzed for pH, acidity, weight, humidity, texture and color. The irradiation did not affect the chemical characteristics of the cassava. Neither the pH nor the acidity, the most relevant variables to verify deterioration in cassava, presented significant alterations during the period of storage. Comparing the irradiated ...

2005-07-01

142

Adsorption capability of charcoal: a comparison study of some activated and non-activated charcoal samples  

Energy Technology Data Exchange (ETDEWEB)

Experiments were carried out to determine the adsorption capability of some commercial activated and non-activated charcoal samples with methanol to select the most favourable pair to be used in a solar adsorption refrigeration system. The results obtained are presented. A simple method has been used to enhance the adsorption capability of the lumpwood charcoal. (Author)

1994-01-01

143

Density separation of materials by using magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...

1980-03-01

144

NATIONAL HIGH MAGENTIC FIELD LABORATORY FEL INJECTOR DESIGN CONSIDERATION  

Energy Technology Data Exchange (ETDEWEB)

A Numerical study of beam dynamics was performed for two injector systems for the proposed National High Magnetic Field Laboratory at the Florida State University (FSU) Free Electron Laser (FEL) facility. The first considered a system consisting of a thermionic DC gun, two buncher cavities operated at 260 MHz and 1.3 GHz and two TESLA type cavities, and is very similar to the injector of the ELBE Radiation Source. The second system we studied uses a DC photogun (a copy of JLab FEL electron gun), one buncher cavity operated at 1.3 GHz and two TESLA type cavities. The study is based on PARMELA simulations and takes into account operational experience of both the JLab FEL and the Radiation Source ELBE. The simulations predict the second system will have a much smaller longitudinal emittance. For this reason the DC photo gun based injector is preferred for the proposed FSU FEL facility.

2007-06-25

145

Design of the ZTH vacuum liner  

Energy Technology Data Exchange (ETDEWEB)

The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between ...

1987-01-01

146

CARM-klystron amplifier for accelerator applications  

International Nuclear Information System (INIS)

We consider the possibility of a cyclotron-autoresonance-maser (CARM) klystron configuration for accelerator applications as an alternative to the gyroklystron amplifier. The potential advantages, compared to gyroklystrons, include: 1) comparable efficiencies at lower values of the electron beam pitch ratio #alpha#, which should improve the beam quality and make the device substantially more stable against the excitation of parasitic mode, 2) operation far from cutoff, which should reduce the fields at cavity walls, allowing higher power operation, and 3) operation at lower magnetic fields for the same cyclotron harmonic number. However, there are two significant issues associated with the design of efficient, high-power CARMs. First, because of the higher value of k_Z, compared to gyroklystrons, CARMs are substantially more sensitive to parallel velocity spread (pitch-angle spread). Second, ...

2001-05-31

147

A high-intensity plasma-sputter heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A multicusp magnetic field plasma surface ion source, normally used for H/sup /minus//ion beam formation, has been modified for the generation of high-intensity, pulsed, heavy negative ion beams suitable for a variety of uses. To date, the source has been utilized to produce mA intensity pulsed beams of more than 24 species. A brief description of the source, and basic pulsed-mode operational data, (e.g., intensity versus cesium oven temperature, sputter probe voltage, and discharge pressure), are given. In addition, illustrative examples of intensity versus time and the mass distributions of ion beams extracted from a number of samples along with emittance data, are also presented. Preliminary results obtained during dc operation of the source under low discharge power conditions suggest that sources of this type may also be used to produce high-intensity (mA) dc beams. The results of these investigations are given, as ...

1989-01-01

148

Inductive technique for measuring critical current densities in thin-film superconductors  

Energy Technology Data Exchange (ETDEWEB)

A technique and a particular apparatus for an inductive measurement of critical currents as a function of temperature and magnetic field in thin-film superconductors are described. The technique has been found to be particularly useful for high-field A-15 compounds 2 to 3 ..mu..m thick. Samples with lower critical current densities would have to be correspondingly thicker to measure over the same broad range of temperature and field. The design of the apparatus is detailed showing that the film can be taken directly from the deposition chamber and mounted without electrical contacts so samples can be changed easily. The principles of operation are developed based on the Critical State Model. These principles are tested by measurements which verify that the measured value of critical curent is independent of the amplitudes and frequency of the small ac magnetic field which is added to a much larger quasistatic field. The ...

1983-01-01

149

Physical and optical properties of rare earth cobalt magnets  

Energy Technology Data Exchange (ETDEWEB)

Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.

1980-08-01

155

METHOD OF FORMING THIN MAGNETIC FILM  

J-STORE (Japan)

Full Text Available

2007-10-04

161

NASA TECH BRIEF  

Science.gov (United States)

Magnetic Forming Studies. The use of transient high magnetic-field devices has made possible the generation of very large accurately ...

163

Magnetic properties of single crystalline RE_2PdSi_3 intermetallic compounds  

International Nuclear Information System (INIS)

... susceptibility magnetization magnetoresistance monocrystals order-disorder

164

Finite Element Analysis of Magnetoelastic Plate Problems.  

Science.gov (United States)

... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...

1981-08-01

165

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

166

An investigation of the decoupling effects in a magnetic forming beryllium coil assembly.  

Science.gov (United States)

Decoupling force exerted by magnetic forming Be coil assembly on metallic plate during forming

1968-01-01

168

International Symposium on Magnetic Suspension Technology. Part 2  

International Nuclear Information System (INIS)

In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.

1991-08-19

169

Seven years of operating experience with amorphous metal transformers  

Energy Technology Data Exchange (ETDEWEB)

Amorphous metals have an atomic structure resembling that of glass, and have high strength, toughness, and excellent magnetic properties for transformer applications. This type of metal has the potential to reduce the core losses of electromagnetic apparatus by 70-75% compared to the best grain-oriented silicon iron currently used. If all 4 million distribution transformers now in service in Canada were replaced by the more efficient amorphous units, it is estimated that over 5.25 billion kWh of energy could be saved annually. The experience of the General Electric (GE) Company and other researchers with operation of amorphous transformers is described. GE first tried operating amorphous metal transformers on a utility distribution system in April 1982. The shell-type cruciform design showed stable, low-loss performance over eight years of service. GE and the Electric Power Research Institute cooperated on manufacturing and ...

1991-05-01

170

FEA Analysis of AP-0 Target Hall Collection Lens (Current Design)  

Energy Technology Data Exchange (ETDEWEB)

The AP-0 Target Hall Collection Lens is a pulsed device which focuses anti-protons just downstream of the Target. Since the angles at which the anti-protons depart the Target can be quite large, a very high focusing strength is required to maximize anti-proton capture into the downstream Debuncher Ring. The current design of the Collection Lens was designed to operate with a focusing gradient of 1,000 T/m. However, multiple failures of early devices resulted in lowering the normal operating gradient to about 750 T/m. At this gradient, the Lens design fares much better, lasting several million pulses, but ultimately still fails. A Finite Element Analysis (FEA) has been performed on this Collection Lens design to help determine the cause and/or nature of the failures. The Collection Lens magnetic field is created by passing high current through a central conductor cylinder. A uniform current distribution through the cylinder ...

2001-06-22

171

{delta}f simulation of ion neoclassical transport  

Energy Technology Data Exchange (ETDEWEB)

Ion neoclassical transport with finite orbit width dynamics is calculated over whole poloidal cross section by using accurate {delta}f method which employs an improved like-particle collision operator and an accurate weighting scheme to solve drift kinetic equation. Ion thermal transport near magnetic axis shows a great reduction from its conventional neoclassical level due to non-standard orbit topology, like that of previous {delta}f simulation. On other hand, the direct particle loss from confinement region may strongly increase ion energy transport near the edge. It is found that ion parallel flow near the axis is also largely reduced due to non-standard orbit topology. In the presence of steep density gradient, ion thermal conductivity is significantly reduced, and an ion particle flux is driven by self-collision alone. (author)

1999-07-01

172

Two dimensional NMR and NMR relaxation studies of coal structure  

Energy Technology Data Exchange (ETDEWEB)

This report covers the progress made on the title project for the project period. Four major areas of inquiry are being pursued. Advanced solid state NMR methods are being developed to assay the distribution of the various important functional groups that determine the reactivity of coals. Special attention is being paid to methods that are compatible with the very high magic angle sample spinning rates needed for operation at the high magnetic field strengths available today. Polarization inversion methods utilizing the difference in heat capacities of small groups of spins are particularly promising. Methods combining proton-proton spin diffusion with [sup 13]C CPMAS readout are being developed to determine the connectivity of functional groups in coals in a high sensitivity relay type of experiment. Additional work is aimed at delineating the role of methyl group rotation in the proton NMR relaxation behavior of coals.

1992-11-25

173

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

174

Stabilizing effect of the electron-beam self-fields on the phase-space trajectory in a self-amplified spontaneous emission free-electron laser operating in ultraviolet and x-ray spectral ranges  

International Nuclear Information System (INIS)

A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction grows exponentially.

2004-02-28

175

Spallation and 14-MeV neutron irradiation of stabilized NbTi superconductors  

Energy Technology Data Exchange (ETDEWEB)

The results on 5 K irradiation available so far may be summarized as follows. (1) Increases of j/sub c/ following neutron irradiation occur only in conductors which are far from the optimal metallurgical treatments. (2) The changes of j/sub c/ following neutron irradiation and a thermal cycle to room temperature are small and in most cases comparable to the results obtained after 77 K irradiation. (3) The data available so far indicate that the degradation of j/sub c/ at 8 T is larger by about 5 to 10% than the corresponding changes at 5 T at a neutron fluence of 1.3 x 10/sup 22/ m/sup -2/ (E > 0.1 MeV). (4) The increase of Cu-resistivity is significant even after a thermal cycle to room temperature and requires design changes for a stable magnet operation.

1983-08-01

176

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

177

Results from Amanda  

Energy Technology Data Exchange (ETDEWEB)

In this report we present an update on the results from the Amanda-B10 detector which operated in 1997 at depths of 1500 to 2000 meters in the deep Antarctic ice. The goal of Amanda project is to search for extra-terrestrial neutrinos. As a precursor to such a search we have studied atmospheric neutrinos which act as a calibration source for the detector. The observation of atmospheric neutrinos at a rate consistent with Monte-Carlo predictions establishes Amanda-B10 as a neutrino telescope. The Amanda-B10 data has been searched for evidence of several classes of neutrinos and for magnetic monopoles. Searches for a diffuse high energy neutrino flux and for neutrinos in coincidence with gamma-ray bursts have been conducted. Preliminary data analyses show no excess of neutrinos has been found. (A.C.)

2001-07-01

178

Overview of industrial applications of induction; L'induction au service de l'industrie: panorama des applications industrielles  

Energy Technology Data Exchange (ETDEWEB)

Because power requirements in induction heating applications are largely dependent on the physical properties of the product to be heated, inducting, heating is mainly used in steelwork applications, for the manufacture of finished or semi-finished parts. Applications here cover five main types of steelworks operation: smelting, heating prior to forming, heat treatment, surface treatment, and assembly process. At the same time, technological progress has opened up innovative applications in sectors such as chemical and agro-food industries. Other emerging applications for induction include direct forming of liquid metal, wholly or partially replacing mechanical transformations on solid metal. Techniques include electromagnetic forming, continuous cold-crucible casting, electromagnetic mixing, flow control by continuous magnetic field, and production of intense sliding fields (pumps, flow regulation). (author)

2004-05-01

179

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

180

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the ...

2010-11-11

181

Los Alamos Advanced Free-Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

At Los Alamos, we are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact in size, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported using permanent-magnet quadrupoles and dipoles. They will form an electron beam with an excellent instantaneous beam quality of 10 {pi} mm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends form 3.7 {mu}m to 0.4 {mu}m. In this paper, we will describe the project and the programs to date. 10 refs., 10 figs., 1 tab.

1991-01-01

182

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may be employed to ...

1991-10-02

183

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

184

Brain tumor in childhood. Hjernesvulst hos barn  

Energy Technology Data Exchange (ETDEWEB)

Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.

1990-05-01

185

Design of a magnetic braking system  

International Nuclear Information System (INIS)

A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted magnetic flux is within ...

2006-09-01

186

The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type  

Energy Technology Data Exchange (ETDEWEB)

There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the chamber to readout the voltage. For operation conditions of the apparatus, observation ...

1999-09-01

187

Measurement of magnetic fields in the Area Metropolitana  

International Nuclear Information System (INIS)

The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which were chosen because are areas with high population density and also in proximity to antennas that emit electromagnetic waves. ...

188

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

189

Magnetic fluctuation measurement in Sino United Spherical Tokamak plasma  

International Nuclear Information System (INIS)

To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)

2007-07-01

190

Transformation of the ATOMKI-ECRIS into a Plasma Device  

International Nuclear Information System (INIS)

Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check the components and charge-state of the plasma. A new, large, but ...

2006-01-01

191

The magnetoresonance operation of microwiggler on the piezoelectrics with a strong magnetic guide field  

Energy Technology Data Exchange (ETDEWEB)

We proposed that a new type of the electrostatic microwiggler with a wiggler period (0.1 mm {le}1{sub w}{le}1 mm) and the wiggler field strength (E{sub w}{le} 100 kV/m) can be produced on the surface of a PZT when a high power and high frequency ultrasonic wave travels through a PZT bar. Numerical simulations in the linear and nonlinear gain regime show that a weak microwiggler (E{sub w}100 kV/m,{lambda}{sub w}{approx}100 periods), operating in magnetoresonance with a strong guide field (B{sub o}{approx} 3.6T), can generate a millimeter and submillimeter radiations with medium electronic efficiency of few percents. It is shown that the maximum output power of the compact FEL using the wiggler system generated on the surface of the piezoelectric material may be upto a few Watts with a relatively low energy and low current electron beam (Ew {approx}100 keV and I{sub b}1 mA).

1995-12-31

192

Stability analysis of forced-flow cooled superconducting coil; Numerical simulation on multiple stability. Kyosei reikyaku gata chodendo coil no anteisei kaiseki; Taju anteisei no simulation  

Energy Technology Data Exchange (ETDEWEB)

The stability of a forced-flow cooled superconducting coil is investigated by use of the numerical simulation. The numerical code to integrate the simultaneous partial differential system composed of the 1 D hydrodynamic equations and the 1 D thermal conduction equation has been developed and stability margins are evaluated as functions of coolant mass flow rate, operation current and imposed magnetic field. The results of computations show that the stability margin is multi-valued with respect to these operation parameters, as expected from the experimental results. It is also shown that the appearance of the first unstable regime is closely related to the existance of the stagnant region located at the upstream side of the heated zone and that the second stable regime appears because the heat transfer is appreciably enhanced by the induced backflow due to the thermal expansion of coolant. 13 refs., 13 figs., 1 tab.

1990-06-25

193

Simulation of electromechanical and thermomechanical loads on first wall mock-ups  

International Nuclear Information System (INIS)

During the operation of a tokamak, the first wall elements suffer very high heat fluxes. Heat is removed by internal cooling by means of water, helium or fluid metal. The resulting inhomogeneous temperature field cause internal stresses which, due to the pulsed operation are of cyclic nature. Additional mechanical stresses in the first wall may be caused by disruptions or vertical plasma movements. During theses events high currents are induced in the metallic part of the first wall which by their interaction with the magnetic field of the tokamak lead to mechanical forces. These electromechanical stresses may lie beyond the yield stress of the structural material. From the interaction of thermal and mechanical forces, a complex stress state is achieved which under certain circumstances may lead to premature failure and/or to progressive plastic deformations (ratcheting). In order to study the boundary conditions for the ...

194

Front-End-Electronics Communication software for multiple detectors in the ALICE experiment  

Energy Technology Data Exchange (ETDEWEB)

In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps that were taken to fulfill the imposed ...

2006-02-15

195

Electron flow in the SABRE linear induction adder in positive polarity  

International Nuclear Information System (INIS)

In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated Transmission Line (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first cavities was greater than in the simulations. The authors have ...

1993-05-17

196

Stirling cooler ILK 15 - refrigeration of 15 W at 80 W; Stirlingkuehler ILK 15 - Kaeltemaschine fuer 15 W bei 80 K  

Energy Technology Data Exchange (ETDEWEB)

The stirling cryocooler ILK 15 is a machine with simple drive concept. This machine works with a conventional built-in electric motor and crank drive and needs a power input of about 500 W. The refrigerating capacity is 15 W at 80 K with a cooldown time of 12 minutes. The cooler is somehow a replacement for the Gifford-McMahon cycle coolers, which are bigger and heavier. The Stirling cryocooler was designed to cool HTSC-components. (orig.) [Deutsch] Der Stirlingkuehler ILK 15 ist eine Kaeltemaschine mit einfachem Antriebskonzept. Die Maschine arbeitet mit einem konventionellen Elektroeinbaumotor und Kurbeltrieb. Sie benoetigt eine Antriebsleistung von 500 W und hat eine Kaelteleistung von 15 W bis 80 K und eine Einkuehlzeit von 12 Minuten. Die Maschine kann als Alternative zur wesentlich groesseren und schweren Gifford-McMahon-Maschine gesehen und bei der Kuehlung von HTSL-Komponenten eingesetzt werden. (orig.)

1998-11-01

197

Performance characteristics of a natural circulation cooling/latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As a result of a 48 hour simulation experiment with load conditions set basing on the ...

1987-09-25

198

Boiling heat transfer in a small horizontal rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Compact heat exchangers have traditionally found wide application in the transportation industry, where they are used as evaporators and condensers in vapor compression cycles for air conditioning and refrigeration. Such heat exchangers possess numerous attractive features including high thermal effectiveness, small size, low weight, design flexibility, and pure counterflow, and they can accommodate multiple streams. Today, there is a widespread interest in expanding the range of application of compact heat exchangers to include phase-change heat transfer in the process industries, among others. An overall objective of this effort is to provide the basis for establishing design technology in this area. In the present study, small channel flow boiling heat transfer was extended to a rectangular channel (4.06 {times} 1.70 mm) using refrigerant 12 (R-12). As with the circular tube studies, the flow channel wall was electrically heated providing a ...

1993-08-01

199

Active packaging of ground beef patties by edible zein films incorporated with partially purified lysozyme and Na2EDTA  

British Library Electronic Table of Contents (United Kingdom)

Summary In this study, antimicrobial activity of zein films incorporated with partially purified lysozyme and disodium ethylenediaminetetraacetic acid (Na2EDTA) has been tested on selected pathogenic bacteria and refrigerated ground beef patties. The developed films containing 700-g-cm-2 lysozyme and 300-g-cm-2 Na2EDTA showed antimicrobial activity on Listeria monocytogenes, Escherichia coli O157:H7, and Salmonella typhimurium. The application of lysozyme and Na2EDTA incorporated zein films on beef patties significantly decreased total viable counts (TVC) and total coliform counts after 5-days of storage compared to those of control patties (P-2EDTA or Na2EDTA alone significantly slowed down the oxidative changes in patties during storage (P-P-2EDTA for active packaging of refrigerated mea...

2011-01-01

200

Use and disposal of large home electronic appliances in Vietnam  

British Library Electronic Table of Contents (United Kingdom)

In this study, e-waste flows of five large home appliances (color televisions, refrigerators, washing machines, personal computers, and air conditioners) in Vietnam are investigated. A social survey was performed to investigate the situation on using appliances in households as well as on the disposal of appliances by the first users. Future quantities of e-waste were estimated using a model that combines use of the Weibull distribution, the logistic function, and the population balance model. It was forecast that about 3.86 million appliances, or 114 000 tons, will be discarded in 2010, and about 17.2 million appliances, or 567 000 tons, in 2025, showing a rapid increase of e-waste in the near future.

2009-01-01

201

On the thermal stabilization of the residual austenite in the cold upsetting steel 100Cr6  

Energy Technology Data Exchange (ETDEWEB)

Once again residual austenite as one component of the microstructure of steels is the basis for discussion among experts. Very often the phenomen of the stabilisation of residual austenite is the focus of interest. In this paper the influence of ageing on residual austenite transformations is discussed, with ageing taking place in a temperature range between ambient and M/sub s/-temperature after quenching from different austenitizing temperatures by means of subzero refrigeration. Results which are typical for 100Cr6 steel are presented and discussed.

1988-07-01

202

Heat transfer equipment design  

Energy Technology Data Exchange (ETDEWEB)

A comprehensive presentation is made of state-of-the-art configurations and design methodologies for heat transfer devices applicable to industrial processes, automotive systems, air conditioning/refrigeration, cryogenics, and petrochemicals refining. Attention is given to topics in heat exchanger mechanical design, single-phase convection processes, thermal design, two-phase exchanger thermal design, heat-transfer augmentation, and rheological effects. Computerized analysis and design methodologies are presented for the range of heat transfer systems, as well as advanced methods for optimization and performance projection.

1988-01-01

203

Compact heat exchangers for condensation applications: Yesterday, today and tomorrow  

Energy Technology Data Exchange (ETDEWEB)

Compact heat exchangers are being increasingly considered for condensation applications in the process, cryogenic, aerospace, power and refrigeration industries. In this paper, different configurations available for condensation applications are analyzed and the current state-of-the-knowledge for the design of compact condensers is evaluated. The key technical issues for the design and development of compact heat exchangers for condensation applications are analyzed and major advantages are identified. The experimental data and performance prediction methods reported in the literature are analyzed to evaluate the present design capabilities for different compact heat-exchanger configurations. The design flexibility is evaluated for the development of new condensation applications, including integration with other process equipment.

1993-07-01

204

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...

1999-04-01

205

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

206

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

207

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -I. 6. Neutronics Analyses for Beamline Upgrades to the High Flux Isotope Reactor  

International Nuclear Information System (INIS)

The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...

2001-06-17

208

Vacuum arc ignition by penning discharge in a strong magnetic field  

Energy Technology Data Exchange (ETDEWEB)

Vacuum arc with cathode spots on the cold electrode is widely used as a plasma generator in a such kind of devices like metal ion sources, plasma cathode electron guns, thing films deposition facilities and others. Most vacuum arc devices utilize a high voltage discharge across an insulator surface to provide a trigger plasma which in turn initiates the main arc discharge. Operation of vacuum arc in a repetitively pulsed mode required a stable triggering system for the long time. But with a discharge across the insulators the number of stable pulses is limited by 100,000 or little bit more. The better method for vacuum arc ignition is low pressure discharge. As shown in this paper it is possible to increase the lifetime of the ignition system in 10 times at least, but negative characteristic of this system is a relatively high pressure (about 0.1 mtorr). In some kinds of vacuum arc applications it is impermissible because it leads to the ...

1995-12-31

209

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We ...

2005-04-01

210

Magnetic properties of materials  

Energy Technology Data Exchange (ETDEWEB)

A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)

2000-08-15

211

Magnetic flocculation and filtration  

Energy Technology Data Exchange (ETDEWEB)

A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.

1996-10-01

212

Advanced Underground Gas Storage Concepts: Refrigerated-Mined Cavern Storage, Final Report  

Energy Technology Data Exchange (ETDEWEB)

Over the past 40 years, cavern storage of LPG's, petrochemicals, such as ethylene and propylene, and other petroleum products has increased dramatically. In 1991, the Gas Processors Association (GPA) lists the total U.S. underground storage capacity for LPG's and related products of approximately 519 million barrels (82.5 million cubic meters) in 1,122 separate caverns. Of this total, 70 are hard rock caverns and the remaining 1,052 are caverns in salt deposits. However, along the eastern seaboard of the U.S. and the Pacific northwest, salt deposits are not available and therefore, storage in hard rocks is required. Limited demand and high cost has prevented the construction of hard rock caverns in this country for a number of years. The storage of natural gas in mined caverns may prove technically feasible if the geology of the targeted market area is suitable; and economically feasible if the cost and convenience of service is competitive with alternative available ...

1998-09-30

213

Extension of improved particle and energy confinement regime in the core of LHD plasma  

International Nuclear Information System (INIS)

Recent two major topics of Large Helical Device (LHD) towards fusion relevant conditions, high-density operation and high-ion-temperature operation, are reported. Super dense core plasma was obtained by the combination of repetitive hydrogen ice pellet injection and high power neutral beam injection (NBI) heating. A very peaked density profile with the highest central density of 1.1x1021 m-3 was produced showing that the particle transport was suppressed very well in the plasma core. The spatial density varies as the position of magnetic axis (Rax), and the steepest profile is obtained at Rax=3.95 m. The highest central ion temperature of 5.6 keV was obtained in hydrogen plasma at electron density of 1.6 x 1019 m-3 by NBI, where a peaked ion-temperature profile with internal ion energy transport barrier was observed. The profile of electron temperature did not change much and was broad even when the ion temperature had a ...

2009-06-01

214

The effective longitudinal dielectric constant for plasmas in inhomogeneous magnetic fields  

Scientific Electronic Library Online (English)

Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.

2004-09-01

215

Magnetic mirror fusion systems: Characteristics and distinctive features  

Energy Technology Data Exchange (ETDEWEB)

A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.

1987-08-10

216

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

217

Magnetic excitations studied with time-of-flight spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.

1996-11-01

218

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

219

Nanocrystalline permanent magnets with enhanced properties  

International Nuclear Information System (INIS)

Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

2001-09-23

220

Spacer grid effects on post-CHF heat transfer in an annulus geometry  

Energy Technology Data Exchange (ETDEWEB)

The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased safety margins. For ...

2005-07-01

221

Spacer grid effects on post-CHF heat transfer in an annulus geometry  

International Nuclear Information System (INIS)

The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased safety margins. For instance, advanced PWRs ...

2005-05-26

222

Untitled - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...

223

Symptoms of the musculoskeletal system and exposure to magnetic fields in an aluminium plant.  

UK PubMed Central (United Kingdom)

OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available

1995-08-01

224

Possible observation of the coexistence of superconductivity and long-range magnetic order in NdRh_4B_4  

International Nuclear Information System (INIS)

The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).

1979-01-01

225

PLASMA JET WELDING, COATING, AND CUTTING: AN ...  

Science.gov (United States)

... 31. New electric forming methods offer potentials for light metals; magnetic forming and plasma forming. ... 3, 25 Magnetic Forming ..... ...

1963-02-01

226

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

Energy Technology Data Exchange (ETDEWEB)

Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-15

227

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

International Nuclear Information System (INIS)

Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-01

228

Mechanism of viscosity effect on magnetic island rotation  

Energy Technology Data Exchange (ETDEWEB)

It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)

2000-04-01

229

Magnetic Properties of Ni Nanoparticles Embedded in ...  

Science.gov (United States)

... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...

2011-05-14

230

Localization of small magnets against a noisy background  

Science.gov (United States)

Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.

2001-05-01

231

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

232

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...

2005-02-01

233
234

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI ...

2009-05-15

235

Evaluation of Commercial Magnetic Descalers.  

Science.gov (United States)

With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...

1984-01-01

236

Develop Magnetic Coil Design and Manufacturing Capability.  

Science.gov (United States)

... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...

1974-11-01

238

CONTRACT: NAS 8-11811 DESIGN, DEVELOPMENT, MANUFACTURE, AND ...  

Science.gov (United States)

has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magnetic coil is placed over a thin aluminum ...

239

Application of the grazing angle polarized neutron reflectometry to study the magnetism in thin films and stratified media  

Energy Technology Data Exchange (ETDEWEB)

From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...

1992-12-01

240

Anisotropic forming of magnetic powders mixed with ultraviolet resin; Shigaisen koka jushi wo mochiita jisei funmatsu no haiko seikei  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...

1999-01-15

241

An Advance in Superconducting Magnet Technology Opens the Door...  

Science.gov (United States)

magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...

2011-08-20

242

Magnetic properties of a SmNiSn single crystal  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the ...

2003-04-01

243

Development of magnetic drive packless valves for commercial purpose  

Energy Technology Data Exchange (ETDEWEB)

A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting ...

1995-09-01

244

Challenges in fabrication of 180deg magnet chamber  

International Nuclear Information System (INIS)

180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector ...

2006-11-01

245

AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab  

Energy Technology Data Exchange (ETDEWEB)

Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar ...

1992-09-01

247

Optimal capacity of the battery energy storage system in a power system  

Energy Technology Data Exchange (ETDEWEB)

Due to the cyclical human life, utility loads appear to be cyclical too. During daytime when most factories are in operation, the electricity demand is very high. On the contrary, when most people are sleeping from midnight to daybreak, the electric load is very low, usually only half of the peak load amount. To meet this large gap between peak load and light load, utilities must idle many generation plants during light load period while operating all generation plants during peak load period no matter how expensive they are. This low utilization factor of generation plants and uneconomical operation have sparked utilities to invest in energy storage devices such as pumped storage plants, compressed air energy storage plants, battery energy storage systems (BES) and superconducting magnetic energy storage systems (SMES) etc. Among these, pumped storage is already commercialized and is the most widely ...

1993-12-01

248

Observations of plasma wave turbulence generated around large ionospheric spacecraft: Effects of motionally induced EMF and of electron beam emission  

International Nuclear Information System (INIS)

The authors report on observations of plasma wave turbulence generated during electron beam injections, spacecraft potential variations, and neutral gas emissions of the CHARGE 2 sounding rocket experiment. The payload was flown in a mother/daughter configuration, with the two sub-payloads electrically connected by an insulated, conducting tether. While tethered, the two platforms were separated, drifting apart in a direction perpendicular to both the magnetic field and to the spacecraft velocity, reaching a maximum distance of 426 m at the end of the flight. The mother carried a high-voltage (HV) system (0-460 V), biasing the mother negative relative to the daughter. The operation of the HV bias system simulated the motional emf induced in larger orbiting space structures like the Tethered Satellite System 1 (TSS 1) space shuttle mission scheduled for the spring of 1992. In addition, the mother carried an electron beam accelerator (1 keV, 0-46 ...

249

Simplified fusion power plant costing. A general prognosis and call for `new think`  

Energy Technology Data Exchange (ETDEWEB)

A top-level costing model is developed and used to project the cost of electricity (COE) (in mills per kilo watt-hour) expected from conceptual fusion power plants. Application is restricted to magnetic fusion energy (MFE) concepts. These costs are estimated parametrically in terms of the mass of the fusion-power-core (FPC) heater, the power required to sustain a reacting deuterium-tritium plasma, the heat transport/transfer system that delivers the fusion power to the balance of plant (BOP), and the BOP needed to convert the fusion heat to electrical power. Although the highly integrated (simplified) cost-estimating relationships (CERs) used to express COE in terms of FPC mass power density (MPD) [in kilowatt(electric) per tonne] and the engineering gain Q{sub E} (inverse of fraction of gross electric power recirculated to the fusion power plant) apply primarily to MFE approaches to fusion power, the costing gauge thus results is generally independent of ...

1995-03-01

250

Implications of high temperature superconductors for power generation  

International Nuclear Information System (INIS)

Superconducting generators for high power applications have been of interest for a number of years. Superconducting generators using low temperature superconductors (LTS) have been manufactured to produce up to 20 MW of electrical power and have been configured in either synchronous alternators which have an AC output that may be subsequently rectified to produce DC and homopolar generators which produce low voltage DC. Typically these generators require scrupulous attention to vacuum integrity for cryogenic insulation at 4.2K and tend to be somewhat fragile because of extensive thermal and magnetic shields that are not required in conventional power generators. Recently, high purity aluminum composites have been developed for a high power AC generator that is cooled by cryogenic hydrogen at 21K. This aluminum generator is very compact and lightweight and is much more robust than a generator made with LTS because extensive thermal and magnetic ...

1991-08-03

251

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have been well without ...

2008-04-15

254

The Effect of Static Magnetic Forces on Water Contents and Photosynthetic Pigments in Sweet Basil Ocimum basilicum L. (Lamiaceae)  

International Nuclear Information System (INIS)

Three different magnetic regimes; aerial, surface and buried; each with three different forces, have been used to investigate their effects on the water contents and photosynthetic pigments of sweet basil plants (Ocimum basilicum L.). Two groups of sweet basil seeds, Ocimum basilicum L. have been cultivated, one under normal conditions and the second has been subdivided into three portion (aerial, surface and buried) to examine the effect of different magnetic forces coming from the three directions on the resulted plants. At all directions of magnets, water contents have been significantly affected by the magnetic forces. Chlorophyll A and carotene contents have been affected, as well, according to the three magnetic forces coming from soil surface regime only. Chlorophyll B did not significantly affected by differences magnetic forces in the three regimes, but ...

255

THE APPLICATION OF STEEP PULSE CURRENTS TO THE ...  

Science.gov (United States)

... Title : THE APPLICATION OF STEEP PULSE CURRENTS TO THE ELECTROHYDRAULIC AND MAGNETIC FORMING OF METALS. ...

1966-04-01

262

Recovery Effects of a 180?mT Static Magnetic Field on Bone Mineral Density of Osteoporotic Lumbar Vertebrae in Ovariectomized Rats  

UK PubMed Central (United Kingdom)

The effects of a moderate-intensity static magnetic field (SMF) on osteoporosis of the lumbar vertebrae were studied in ovariectomized rats. A small disc magnet (maximum magnetic flux density 180 mT)...Full Text Available

2011-01-01

263

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

264

Perpendicular magnetic anisotropy of ultrathin FeCo alloy films on Pd(0 0 1) surface: First principles study  

International Nuclear Information System (INIS)

Using the full potential linearized augmented plane wave (FLAPW) method, thickness dependent magnetic anisotropy of ultrathin FeCo alloy films in the range of 1 monolayer (ML) to 5 ML coverage on Pd(0 0 1) surface has been explored. We have found that the FeCo alloy films have close to half metallic state and well-known surface enhancement in thin film magnetism is observed in Fe atom, whereas the Co has rather stable magnetic moment. However, the largest magnetic moment in Fe and Co is found at 1 ML thickness. Interestingly, it has been observed that the interface magnetic moments of Fe and Co are almost the same as those of surface elements. The similar trend exists in orbital magnetic moment. This indicates that the strong hybridization between interface FeCo alloy and Pd gives rise to the large magnetic moment. Theoretically calculated ...

2009-06-01

266

Optimization of soft magnetic properties in Fe-B and Fe-B-Si amorphous alloys obtained by melt spinning method  

International Nuclear Information System (INIS)

In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)

2001-09-23

267

NASA Technical Reports Server - Magnetic forming coil design and ...  

Science.gov (United States)

Site Error There's a problem with your browser or settings. ...

272

Magnetic forming studies  

Science.gov (United States)

Elastodynamic approach to measuring stress-strain relationship of uniaxially stressed wire, and

1967-01-01

274

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

275

Magnetic electronic lenses, quadrupole and octupole for microsystem electron beam techniques  

International Nuclear Information System (INIS)

The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered

2006-09-01

279

Influence of rotation and magnetic field on the minimum mass of a main-sequence star  

Energy Technology Data Exchange (ETDEWEB)

The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.

1980-11-01

296

A STUDY TO DETERMINE THE DEFORMATION ...  

Science.gov (United States)

... crystals and polycrystals. Nevertheless, explosive forming, magnetic forming, etc., are all high-strain-rate processes that ...

1963-04-01

297

A HELICAL MAGNET DESIGN FOR RHIC.  

Energy Technology Data Exchange (ETDEWEB)

Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.

1997-05-12

298

Two dimensional NMR and NMR relaxation studies of coal structure. Progress report, July 1, 1992--September 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

This report covers the progress made on the title project for the project period. Four major areas of inquiry are being pursued. Advanced solid state NMR methods are being developed to assay the distribution of the various important functional groups that determine the reactivity of coals. Special attention is being paid to methods that are compatible with the very high magic angle sample spinning rates needed for operation at the high magnetic field strengths available today. Polarization inversion methods utilizing the difference in heat capacities of small groups of spins are particularly promising. Methods combining proton-proton spin diffusion with {sup 13}C CPMAS readout are being developed to determine the connectivity of functional groups in coals in a high sensitivity relay type of experiment. Additional work is aimed at delineating the role of methyl group rotation in the proton NMR relaxation behavior of coals.

1992-11-25

299

Time-Dependent 2D Modeling of Magnetron Plasma Torch in Turbulent Flow  

International Nuclear Information System (INIS)

A theoretical model is presented to describe the electromagnetic, heat transfer and fluid flow phenomena within a magnetron plasma torch and in the resultant plume, by using a commercial computational fluid dynamics (CFD) code FLUENT. Specific calculations are presented for a pure argon system (i.e., an argon plasma discharging into an argon environment), operated in a turbulent mode. An important finding of this work is that the external axial magnetic field (AMF) may have a significant effect on the behavior of arc plasma and thus affects the resulting plume. The AMF impels the plasma to retract axially and expand radially. As a result, the plasma intensity distribution on the cross section of torch seems to be more uniform. Numerical results also show that with AMF, the highest plasma temperature decreases and the anode arc root moves upstream significantly, while the current density distribution at the anode is more concentrated with a ...

2008-06-01

300

Performance of distance relays in a 150 kV grid in case of cross-country faults. Gedrag van distantiebeveiligingen in een 150 kV-net bij cross-country fouten  

Energy Technology Data Exchange (ETDEWEB)

In the 150 kV power system of the Dutch energy utility MEGA Limburg cross-country faults have caused problems in the protection of high voltage transmission lines. A cross-country fault is the simultaneous presence of two single-phase earth connections in different phases and places within the grid. These cross-country faults can lead to the incorrect operation of a number of distance relays, which could result in the faulty disconnection of high voltage transmission lines. To gain an insight into these problems, the transient phenomenon in the power system during cross-country faults were studied. For this purpose, the simulation program EMTP (ElectroMagnetic Transients Program) has been used. Simulation models of the 150 kV power system and the measuring system of a distance relay were developed within EMTP. 7 figs., 1 ill.

1994-11-01

301

Materials needs for compact fusion reactors  

Energy Technology Data Exchange (ETDEWEB)

The economic prospects for magnetic fusion energy can be dramatically improved if for the same total power output the fusion neutron first-wall (FW) loading and the system power density can be increased by factors of 3 to 5 and 10 to 30, respectively. A number of compact fusion reactor embodiments have been proposed, all of which would operate with increased FW loadings, would use thin (0.5 to 0.6 m) blankets, and would confine quasi-steady-state plasma with resistive, water-cooled copper or aluminum coils. Increased system power density (5 to 15 MWt/m/sup 3/ versus 0.3 to 0.5 MW/m/sup 3/), considerably reduced physical size of the fusion power core (FPC), and appreciably reduced economic leverage exerted by the FPC and associated physics result. The unique materials requirements anticipated for these compact reactors are outlined against the well documented backdrop provided by similar needs for the mainline approaches. Surprisingly, no single ...

1983-01-01

302

MRS of normal and impaired fetal brain development  

International Nuclear Information System (INIS)

Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are ...

2006-02-01

303

Longitudinal and transverse dynamics of a free electron laser based on a storage ring of second and third generation  

International Nuclear Information System (INIS)

This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a modulation, the FEL can present a periodic or chaotic regime. The ...

304

Diagnosing mechanical changes: A test of the machine condition monitoring concept  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro recently conducted a demonstration test of a bearing condition monitor. The test, at the 529-MW Kootenay Canal project, proved the ability of the monitor to detect machine condition faults. The capability to detect changing conditions during normal operation of hydroelectric machines gives hydro plant owners the opportunity to anticipate needed maintenance and ultimately to reduce the number of equipment failures. BC Hydro intends to install bearing condition monitors, as well as windings monitors, brushgear monitors, environmental monitors, and other selected systems in as many as 46 of its hydro generators. BC Hydro analyzed forced outages between 1985 and 1989 in its hydro system to identify which parts of a generating unit resulted in the highest number of hours of outage. From there, the utility has formulated a concept for a machine condition monitoring system. To keep the system cost effective, it will be developed in modules. In this way, users can ...

1993-05-01

305

Authentication via wireless networks  

CERN Document Server

Personal authentication is an important process we encounter almost every day; when we are logging on a computer, entering a company where we work, or a restricted area, when we are using our plastic credit cards to pay for a service or to complete some other financial transaction, etc. In each of these processes of personal authentication some kind of magnetic or optical token is required. But by using novel technologies like mobile computing and wireless networking, it is possible to avoid carrying multitude of ID cards or remembering a number of PIN codes. Article shows how to efficiently authenticate users via Personal Area Networks (PAN) like Bluetooth or IrDA using commonplace AES (Rijndel) or MD5 encryption. This method can be implemented on many types of mobile devices like Pocket PC PDA with Windows CE (Windows Mobile 2003) real-time operating system, or any other customized OS, so we will explain all components and key features of ...

2007-01-01

306

An economic assessment of the application of superconductor technology to magnetic-levitation trains in Oklahoma  

International Nuclear Information System (INIS)

Specific objectives were to: (1) develop and refine a methodology that can be used to evaluate the feasibility of MAG-LEV trains; (2) apply this methodology to the state of Oklahoma. The methodology is based on an aggregate econometric demand model and mathematical programming. A city-pair network is constructed to evaluate alternative MAG-LEV routes between Oklahoma City and nine other cites in and out of the state of Oklahoma. Results obtained from the aggregate econometric demand model indicates that MAG-LEV trains would attract significant ridership along different types of origin-destination routes. All nine corridors exhibit induced demand for MAG-LEV trains as well as attracting riderships from other modes. Based on the results of both single and multiobjective LP models, fixed-capital-cost requirements and annual operating cost for each of the above corridors are estimated, and by using different scenarios for discount rates, both costs and revenue were ...

307

A search for electron cyclotron maser emission from compact binaries  

CERN Document Server

Unipolar induction (UI) is a fundamental physical process, which occurs when a conducting body transverses a magnetic field. It has been suggested that UI is operating in RX J0806+15 and RX J1914+24, which are believed to be ultra-compact binaries with orbital periods of 5.4 min and 9.6 min respectively. The UI model predicts that those two sources may be electron cyclotron maser sources at radio wavelengths. Other systems in which UI has been predicted to occur are short period extra-solar terrestrial planets with conducting cores. If UI is present, circularly polarised radio emission is predicted to be emitted. We have searched for this predicted radio emission from short period binaries using the VLA and ATCA. In one epoch we find evidence for a radio source, coincident in position with the optical position of RX J0806+15. Although we cannot completely exclude that this is a chance alignment between the position of RX J0806+15 and an ...

2007-01-01

308

A conceptual design study of superconducting proton linac for Neutron Science Project. 1  

Energy Technology Data Exchange (ETDEWEB)

The Neutron Science Project at Japan Atomic Energy Research Institute has been proposed for the research of nuclear transmutation technology and the basic science with a spallation neutron source. The project calls for an 8MW proton linac which accelerates 5.3mA average current cw and pulsed beams up to 1.5GeV. The superconducting (SC) rf-cavity is the main option for the energy part from 100MeV to 1.5GeV because by using the SC structure, less power is consumed in cw operation than by using a normal conducting (NC) structure. A conceptual design study of the superconducting proton linac is reported. The SC linac is composed of 8 {beta} sections. Each section has the identical 5-cell cavities with the surface peak field of 16MV/m. The total number of cavities is 284, and the length of the SC linac is 690m. The lattice design is determined with the equipartitioned condition and the matched envelope equations for the minimum emittance growth. The transverse and ...

1998-09-01

309

Magnetocaloric and magnetoresistance studies of GdPd{sub 2}Si  

Energy Technology Data Exchange (ETDEWEB)

The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...

2001-01-22

310

Magnetocaloric and magnetoresistance studies of GdPd_2Si  

International Nuclear Information System (INIS)

The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...

2001-01-22

311

Magnetic separation anxiety  

International Nuclear Information System (INIS)

This paper reports that only a few years ago superconducting magnetic separation was viewed as the next major market for superconducting magnets. The first commercial units had been installed, worked flawlessly, and demonstrated real economic viability. The potential market was seen as quite large, and many people believed that superconducting magnetic separation would soon show the same rapid growth that MRI had demonstrated after its initial success. These hopes even prompted IGC, one of the top MRI magnet builders, to form a separate division devoted to magnetic separation. Despite the existence of Magstream, IGC has not been overly active in the market. As a technology that has applications from the clay on the Earth to the soil on the moon, superconducting magnetic separation has yet to become widely used.

1992-01-01

312

High-mode-number ballooning modes in a heliotron/torsatron system: 1, Local magnetic shear  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal force balance in the stellarator-like ...

1996-05-01

313

Effect of the induced magnetic field on peristaltic flow of a couple stress fluid  

Science.gov (United States)

We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and ...

2008-06-01

314

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

315

On the temperature dependence of the magnetic excitations  

International Nuclear Information System (INIS)

We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# function shows that ...

2005-07-15

316

Theory of zwitterionic molecular-based organic magnets  

British Library Electronic Table of Contents (United Kingdom)

We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.

2011-01-01

317

Occurrence of magnetism in superconductors  

Science.gov (United States)

We discuss how magnetic phenomena affect superconductivity in simple metals, transition metals and alloys thereof, and dilute Rare-Earth alloys. It is shown both qualitatively and quantitatively that superconductors are sensitive probes for studying itinerant spin excitations, local spin excitations associated with nearly magnetic impurities, the effect of the atomic environment on the stability of local magnetic moments, and the nature of the spin order in Rare-Earth alloys. Also, we discuss how magnetic impurities can be used to study the electronic configuration which is responsible for superconductivity in Laves-phase crystals like A-15 compounds and ..beta..-W crystals, for example.

1970-12-14

318

Magnetic response of ultrathin Fe on MgO: A polarized neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.

1994-11-15

319

Magnetic properties of glasses from geothite industrial wastes recycling (FeOOH)  

International Nuclear Information System (INIS)

It has been carried out the magnetic properties determination for high iron oxide content glasses series obtained from a geothite red mud waste from the zinc hydrometallurgy and dolomite and glass cullet as main raw materials. It has been determined the magnetic susceptibility and magnetization values for the glasses here investigated. The results suggest that the magnetic behaviour are depending on the glass chemical composition, so that glasses can be differently classified like ferrimagnetic, ferromagnetic, superparamagnetic and paramagnetic. (Author) 6 refs.

320

Magnetic fluctuations in paramagnetic Mn{sub 0.81}Ni{sub 0.19}  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluctuations present in the paramagnetic Mn{sub 0.81}Ni{sub 0.19} system have been investigated by measuring inelastic magnetic neutron scattering from a single crystal at temperatures of 450, 585 and 700 K. Antiferromagnetic correlations are observed to be present at all the temperatures studied. The spectral width of the magnetic scattering has been observed to increase with temperature, while the spatial range of the magnetic correlations is seen to decrease as the temperature is raised. The wave-vector-dependent susceptibility is found to follow a Curie-Weiss law near the (1 0 0) position, in agreement with theoretical predictions.

2006-11-15

321

Hydromagnetic rotational braking of magnetic stars  

International Nuclear Information System (INIS)

It is suggested that the magnetic Ap stars can be rotationally decelerated to long periods by the braking action of the associated magnetic field on time scales of order 10"7--10"1"0 years depending on whether the star's dipole field is aligned perpendicular or parallel to the rotation axis. Rotation includes a toroidal magnetic field in the plasma surrounding a star, and the accompanying magnetic stresses produce a net torque acting to despin the star. These results indicate that it is not necessary to postulate mass loss or mass accretion for this purely hydromagnetic braking effect.

322

How the Performance of a Superconducting Magnet is affected by theConnection between a small cooler and the Magnet  

Energy Technology Data Exchange (ETDEWEB)

As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the ...

2005-09-08

323

Anisotropic Nd{endash}Fe{endash}B bonded magnets made from HDDR powders (invited)  

Energy Technology Data Exchange (ETDEWEB)

Anisotropic Nd{endash}Fe{endash}B magnet powders can be produced by the hydrogenationdecomposition-desorption-recombination (HDDR) process from Nd{endash}Fe@ xnB{endash}Co{endash}M ({ital M}=Ga, Zr, Nb, Hf, and Ta) alloys. The present status of those HDDR powders and the bonded magnets made from them are reviewed with regards to the powder particle size dependence of their magnetic properties, their magnetic thermal stability, and their magnetization behavior. The results of a mechanistic study on the recombination step are also presented. The magnetic properties of the anisotropic HDDR powder depend relatively little on the powder particle size. Bonded magnets with a density of {approximately}6.20 g/cm{sup 3} and a BH{sub max} of 18.5{endash}20.5 MGOe can be produced from anisotropic HDDR powders with particle sizes of below 300 {mu}m diam. ...

1996-04-01

324

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

325

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

326

Part I: Experimental investigation of the boiling of binary mixtures of Freon-11 and refrigeration lube oils  

Energy Technology Data Exchange (ETDEWEB)

Several experimental runs have been carried out to study nucleate boiling of binary mixtures consisting of Freon-11 and lube oils such as SUNISO 3GS and 4GS in oil concentrations ranging from 0 to 24% by volume. The effect of the heating source temperature on the rate of boiling at various pressures has been studied and the boiling curves at different oil concentrations and pressures have been investigated at an excess temperature of up to 80/sup 0/C. The experimental data have been used to find the effect of pressure, oil concentration and excess temperature on the boiling heat transfer coefficient. The P-T relations for both kinds of mixtures have been measured at different oil concentrations. The heat lost to the atmosphere have also been studied as a function of oil concentration for both kinds of mixtures.

1986-01-01

327

Modelling and simulation of a solar cooler based on physical adsorption; Modelagem e simulacao de um refrigerador solar por adsorcao fisica  

Energy Technology Data Exchange (ETDEWEB)

This study describes the construction of a simple mathematical model its validation through the simulation in transient state of a real cycle performed by a solar refrigerator based on physical adsorption using an activated carbon/methanol pair. The deviation from experimental results was 4% for the cycled mass of methanol, 2.2 % for maximum collector average temperature, and 3 x 10{sup -3} for the theoretical cycle coefficient of performance. Additional simulations of the same cycle inputting values representing different types and larger amounts of activated carbon showed the possibility of increasing the cycled methanol mass up to about 150%. (author) 26 refs., 16 figs., 9 tabs.

1993-12-31

328

Experimental assessment of energy storage via variable speed compressor  

British Library Electronic Table of Contents (United Kingdom)

In this study, usage of a variable speed refrigeration system in latent heat thermal energy storage (LHTES) system is investigated to increase energy storage efficiency. Four different compressor speed control cases are compared to obtain a constant heat transfer fluid (HTF) temperature at the inlet of the energy storage tank. These control cases are (i) control with evaporation temperature, (ii) control with ethylene glycol temperature at the outlet section of evaporator, (iii) control with suction pressure of the compressor and (iv) on/off control. By means of the experimental analysis the best control strategy is obtained as control with Case (ii), in terms of stability of inlet temperature of heat transfer fluid, variations of energy efficiency of LHTES and coefficient of performance (...

2011-01-01

329

Economic thickness for industrial insulation  

Energy Technology Data Exchange (ETDEWEB)

This manual is presented in 8 chapters plus appendices. Chapters 1 and 2 are included as background information. The economic insulation thickness is found using the following chapters: Chapter 3, cost of energy (heat and refrigeration); Chapter 4, cost of insulation, and Chapter 5, economic thickness determination. Each of these chapters contains a worksheet, which provides a step-by-step procedure for solving the problem. Nomographs are included in each section for simplifying the required calculations. For subambient temperature systems, the economic insulation thickness calculated with Chapters 3 to 5 should be compared to the thickness required to prevent condensation (sweating), as calculated with Chapter 6. Chapter 7 presents the procedure for calculating economic insulation for retrofit situations. Sample problems are included in Chapter 8.

1983-01-01

330

Comparison of media and methods for detecting and enumerating Listeria monocytogenes in refrigerated cabbage.  

Science.gov (United States)

Direct plating, selective enrichment, and cold enrichment followed by secondary selective enrichment procedures were compared for detecting and enumerating Listeria monocytogenes in chopped cabbage stored at 5 degrees C for up to 64 days. Addition of Fe3+ to solid media enhanced detection of the organism. Cold enrichment (5 degrees C) in nutrient broth and brain heart infusion broth followed by secondary enrichment (48 h, 30 degrees C) in Trypticase soy-yeast extract-antibiotic broth and thiocyanate-nalidixic acid broth and plating on selective agar media (Doyle and Schoeni selective enrichment agar [minus acriflavin hydrochloride, supplemented with 5 micrograms of Fe3+/ml] and McBride Listeria agar) resulted in the detection of highest populations. PMID:3111369

1987-05-01

331

Air conditioning in high rise buildings; Conditionnement d'air dans les immeubles de grande hauteur  

Energy Technology Data Exchange (ETDEWEB)

This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)

1997-07-01

332

Aerogels: the leading edge in thermal insulation  

Energy Technology Data Exchange (ETDEWEB)

Banning CFCs in foamed insulations has led to an intensive search for alternatives which do not incur the penalty of increased thickness. The most promising of these are silica aerogels, which have proven to be the leading material, when it comes to thermal insulation and environmental protection. Refrigerators insulated with aerogels have been tested and compared to conventionally insulated ones. Results showed a substantial contribution to the energy performance. Boiler manufacturers using aerogel have been able to reduce energy consumption of water heaters by 20%. Float glass elements evacuated and filled with aerogel as well as aerogel insulated polyester lightwalls and bubble skylights yield excellent U-values and significantly reduced energy losses in buildings. (author)

1995-01-01

333

Kondo effect and impurity-impurity interaction in (La, Ce)B_6 alloys  

International Nuclear Information System (INIS)

Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY ...

1978-01-01

334

Development of magnetic separation system of magnetoliposomes  

Energy Technology Data Exchange (ETDEWEB)

The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was ...

2009-10-15

335

Anti-cancer drug loaded iron-gold core-shell nanoparticles (Fe@Au) for magnetic drug targeting.  

Science.gov (United States)

Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus simulating the human ...

2010-09-01

336

"1"5"1Eu-Moessbauer study of complex magnetism in Eu_2PdSi_3: Effect of Eu"2"+ substitution by Y"3"+ and of high pressure  

International Nuclear Information System (INIS)

With "1"5"1Eu-Moessbauer spectroscopy and other methods the complex magnetic properties of Eu_2PdSi_3, arising from the two crystallographically different lattice sites of the Eu"2"+ ions, have been already studied. Here we study the impact of magnetic dilution of the magnetic Eu"2"+ sites by non-magnetic Y"3"+ ions. A previous specific heat study has found reduced magnetic ordering temperatures with strong indication of disorder effects like in magnetic spin glasses. Here we provide from "1"5"1Eu-Moessbauer spectroscopy detailed information of the impact of Y"3"+ substitution on the magnetic properties of the two lattice sites, well distinguishable in the "1"5"1Eu-spectra. Since the substitution of the larger Eu"2"+ ions by the smaller Y"3"+ ions is connected with a lattice contraction, we also applied high pressure to the Eu_2PdSi_3 sample ...

2010-03-01

337

Resistivity, Hall effect, and magnetic susceptibility of UPd_2Si_2  

International Nuclear Information System (INIS)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

338

Resistivity, Hall effect, and magnetic susceptibility of UPd[sub 2]Si[sub 2  

Energy Technology Data Exchange (ETDEWEB)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

1993-12-15

339

Recycler model magnet test on temperature compensation for strontium ferrite  

Energy Technology Data Exchange (ETDEWEB)

The Recycler ring magnet will be made of Strontium ferrite permanent magnets. A strontium ferrite permanent magnet without compensation has a temperature coefficient of -0.2 % in dB/dT. To compensate this effect, we are utilizing 30 % Ni 70 % Fe alloy, a temperature compensation ferromagnetic material with a low Curie point. To search for optimum commercially available material and optimum condition, we made a couple of simple model magnets, and tested with several different compensating material. The test results are reported and its optimal conditions are shown. Several different configurations were tested including a possible 2 kG magnet configuration.

1995-10-01

340

Large specific absorption rates in the magnetic hyperthermia properties of metallic iron nanocubes  

CERN Document Server

We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large heating power.

2010-01-01

341

Itinerant magnetism of Gd_xLa_1_-_xMSi (M=Fe, Co) compounds  

International Nuclear Information System (INIS)

The magnetic properties of polycrystalline and single crystalline rare earth transition metal silicides Gd_xLa_1_-_xMSi (M =Fe, Co) were investigated. Magnetic measurements have been made in static magnetic fields up to 13 kOe and in pulsed magnetic fields up to 250 kOe in the temperature range from 4.2 to 350 K. The magnetic susceptibility in the paramagnetic state of all the investigated compounds obeys the Curie-Weiss law except for LaFeSi and LaCoSi. Increase of the La content in Gd_xLa_1_-_xFeSi compounds leads to a decrease of the Curie and Neel temperatures, which can be explained by a decrease of positive exchange interactions. (orig.).

1995-09-01

342

High Tc superconducting magnetic multivibrators for fluxgate magnetic-field sensors  

Science.gov (United States)

Sensitive and quick-response nonlinear inductance characteristics are found for high Tc superconducting (YBa/sub 2/Cu/sub 3/O/sub 7-chi/) disk cores at 77K in which soft magnetic BH hysteresis loops are observed. Various quick response magnetic devices such as modulators, amplifiers and sensors are built using these cores. The magnetizing frequency can be set to more than 20 MHz, which is difficult for conventional ferromagnetic bulk materials such as Permalloy amorphous alloys and ferrite. New quick-response fluxgate type magnetic-field sensors are made using ac and dc voltage sources. The former is used for second-harmonic type sensors, while the latter is for voltage-output multivibrator type sensors. Stable and quick-response sensor characteristics were obtained for two-core type multivibrators.

1989-09-01

343

Effect of On-Chip Magnetic Shielding for TES Microcalorimeters  

British Library Electronic Table of Contents (United Kingdom)

We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...

2008-01-01

344

Smith-Purcell free-electron laser  

International Nuclear Information System (INIS)

The term Smith-Purcell free electron laser can be employed generally to describe any coherent radiation source in which a diffraction grating is used to couple an electron beam with the electromagnetic field. To date, most practical developments of this concept have focused on devices which operate in the millimeter spectral regime. In this paper construction of a Smith-Purcell free-electron laser operating in the far-infrared (FIR) region using a novel resonator cavity design and the electron beam from a low energy (0.5-5 MeV) radio-frequency accelerator will be discussed. A tunable source in this region would have many applications and since the beam energy is low, the small size and low overall cost of such a device would make it a laboratory instrument. Current projects which are progressing towards developing a FIR source are the programs at Stanford and CREOL. Both of these projects are using permanent magnet ...

1995-08-21

345

Reliability data to improve high magnetic field coil design for high velocity coilguns.  

Energy Technology Data Exchange (ETDEWEB)

Coilguns have demonstrated their capability to launch projectiles to 1 km/s, and there is interest in their application for long-range precision strike weapons. However, the incorporation of cooling systems for repetitive operation will impact the mechanical design and response of the future coils. To assess the impact of such changes, an evaluation of the ruggedness and reliability of the existing 50 mm bore coil designed in 1993 was made by repeatedly testing at stress levels associated with operation in a coilgun. A two-coil testbed has been built with a static projectile where each coil is energized by its own capacitor bank. Simulation models of the applied forces generated in this testbed have been created with the SLINGSHOT circuit code to obtain loads equivalent to the worst-case anticipated in a 50 mm coilgun that could launch a 236 g projectile to 2 km/s. Bench measurements of the seven remaining coils built in 1993 have been used to ...

2003-09-01

346

Edge biasing in the WEGA stellarator  

Energy Technology Data Exchange (ETDEWEB)

The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gas discharges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise measurement of the radial electric field. The focus of this work is ...

2009-02-27

347

Charge distribution analysis of catalysts under simulated reaction conditions. Second quarterly technical progress report, January 1, 1993--March 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

New furnaces were built based on fused silica with NiChrome heating elements custom-wound on alumina ceramic to self-compensate for induced magnetic fields during operation. During tests these furnaces failed due to thermal stresses caused by the high temperature cement used to hold the alumina ceramic in place. As a third solution pieces of boron nitride have been procured from which new furnace bodies will be machined during the third quarter. In order to increase the in-house capacity for machining ceramic parts a small lathe was ordered. The implementation of the LabView data acquisition software from National Instruments, Inc. took more time than anticipated and is still not completed. Major difficulties had to be overcome during the integration of the separate positive and negative high voltage supplies ({plus_minus}1000V). It became apparent that a custom-designed switch had to be installed to safeguard the data acquisition modules and ...

1993-11-01

348

Two-phase flow patterns and frictional pressure gradients in a small, horizontal, rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Two-phase flow patterns and frictional pressure gradients in flow in small, rectangular channels are being studies as part of a larger research program addressing phase-change heat transfer of pure refrigerants and refrigerant mixtures in plate-fin heat exchangers. Small rectangular flow channels were selected as representative of plain fin geometries. The particular channel reported herein has dimensions of 19.05 {times} 3.18 mm. Adiabatic flows of air/water mixtures, with the flow channel horizontal and the channel exit at near-atmospheric conditions, were utilized in the experiments. Analysis and interpretation of the pressure data relative to observed flow pattern transitions led to an objective method for determining the plug/bubble-to-slug flow transition. This method, together with visual observations, supplemented with photographic data, was used to develop a flow pattern man. A comparison of existing flow pattern maps for circular ...

1990-05-01

349

European Space Agency announces contest to "Name the Cluster Quartet"  

Science.gov (United States)

1. Contest rules The European Space Agency (ESA) is launching a public competition to find the most suitable names for its four Cluster II space weather satellites. The quartet, which are currently known as flight models 5, 6, 7 and 8, are scheduled for launch from Baikonur Space Centre in Kazakhstan in June and July 2000. Professor Roger Bonnet, ESA Director of Science Programme, announced the competition for the first time to the European Delegations on the occasion of the Science Programme Committee (SPC) meeting held in Paris on 21-22 February 2000. The competition is open to people of all the ESA member states (*). Each entry should include a set of FOUR names (places, people, or things from history, mythology, or fiction, but NOT living persons). Contestants should also describe in a few sentences why their chosen names would be appropriate for the four Cluster II satellites. The winners will be those which are considered most suitable and relevant for the Cluster II mission. ...

2000-02-01

350

Operation Overlord: An Example of the Command and Control ...  

Science.gov (United States)

... where they discussed Montgomery's failure to pursue Operation Goodwood, ... Operation Goodwood, Montgomery's 18 July attack on Caen ...

1986-02-26

351

Mass: Evolving Tool of the US Operational Artist  

Science.gov (United States)

... ire examples of successive operations, as are the breakout operations GOODWOOD and COBRA. Also, for the first time, ...

1993-05-14

352

How Can Surprise Be Achieved Today at the Operational ...  

Science.gov (United States)

... Then came Montgomery's Operation GOODWOOD in the Caen section. ... the attack during Operation GOODWOOD. The "speed" of ...

1989-06-02

353

Treatment of low-frequency pulsating magnetic field on amorphous alloy Fe_7_8Si_9B_1_3  

International Nuclear Information System (INIS)

Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe_7_8Si_9B_1_3 were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe_7_8Si_9B_1_3. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase (#alpha#-Fe(Si), the grain size, 2-10 nm) is 3-7%. The temperature rise ...

2007-07-15

354

The possible detection of magnetic monopoles and monopole tachyons  

International Nuclear Information System (INIS)

This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.

355

Temperature dependence of a twofold magnetic behaviour of a nanoscopic metal/silicon hybrid system - a comparison between Ni/Si and Co/Si  

Energy Technology Data Exchange (ETDEWEB)

The investigated hybrid nanocomposite consists of a porous silicon template with electrochemically embedded Ni or Co nanostructures and offers magnetic characteristics which can be tailored by the electrochemical process parameters during fabrication. A twofold magnetic behaviour can be observed, a first one due to the spinmagnetism at magnetic fields below the saturation magnetization of the deposited metals and a second non-saturating term at higher fields (>1 T up to 7 T) above the saturation magnetization. In case of Ni deposited within the pores this non-saturating term shows a paramagnetic characteristic and follows exactly the Curie-Weiss law, whereas for Co/porous silicon samples the temperature dependent magnetization shows some deviations from the Curie Weiss law. In this high field region a difference in the temperature dependence between Ni ...

2009-10-15

356

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

357

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

358

Room-temperature magnetic properties of oxy- and carbonmonoxyhemoglobin  

UK PubMed Central (United Kingdom)

The magnetic susceptibility and the density of human oxy-(HbO2) and carbonmonoxyhemoglobin (HbCO) solutions of various concentrations have been measured at room temperature, with pure water...Full Text Available

1978-10-01

359

Residential magnetic fields and childhood leukemia: a meta-analysis.  

UK PubMed Central (United Kingdom)

OBJECTIVES: This article uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies of residential magnetic field...Full Text Available

1998-12-01

360

Print sec333photoindex (256 pages)  

Science.gov (United States)

Electro-Magnet. Antenna Panels Types Simulated Hail Stone Damage A.Panel ...... X-Band Klystron Electro Magnet. 11. I I. 333-6104 AcBc. 333-6105 Color ...

361

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

362

Nature of magnetic coupling between Mn ions in as-grown Ga1-xMnxAs studied by x-ray magnetic circular dichroism  

International Nuclear Information System (INIS)

The magnetic properties of as-grown Ga1-xMnxAs have been investigated by the systematic temperature and magnetic field dependent soft x-ray magnetic circular dichroism (XMCD) measurements in the Mn L2,3 absorption edge region. The XMCD intensity at high temperatures obeys the Curie-Weiss law, but residual spin magnetic moment appears already around 100 K, significantly above Curie temperature (Tc), suggesting that short-range ferromagnetic correlations are developed significantly above Tc. The high-field magnetic susceptibility becomes T-independent below TC, indicating that the AF interaction between the substitutional Mn (Mnsub and interstitial Mn (Mnint) ions, which becomes strong as the Mn concentration x increases, exists and that the amount of the Mnint affects Tc. The present experimental findings should give valuable insight into the inhomogeneous ...

2009-07-01

363

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

364

Magnetic and structural investigation of magnetic thin films with obliquely deposited underlayers  

CERN Document Server

An in-plane uniaxial magnetic anisotropy has been observed in thin Co films normally deposited onto obliquely sputtered Ta and Pt underlayers. Associated with this anisotropy is an augmented easy axis coercivity. The in-plane easy axis is, in most cases, perpendicular to the incident deposition plane. Microstructural results indicate that grains are well connected along the magnetic easy axis but are separated by long continuous voids along the hard axis, which is ascribed to a geometric shadowing effect due to the oblique incidence deposition of the underlayer. Hence, the magnetic anisotropy mimics the film growth anisotropy. It is therefore believed that the observed magnetic properties are due to magnetostatic shape anisotropy effects. In-plane coercivity and anisotropy field are shown to increase with underlayer deposition angle, underlayer thickness and magnetic layer ...

2002-01-01

365

Magnetic and chemical changes in marine sediments  

Energy Technology Data Exchange (ETDEWEB)

A considerable amount of chemical knowledge of marine sediments has been acquired in recent years but has not yet been utilized by paleomagnetists. On the other hand, geochemists are often unaware of the usefulness of numerous magnetic techniques. In this review we try to bridge this gap, and in particular, we outline many of the chemical and magnetic principles that should allow paleomagnetists to better identify and undertand chemical changes that affect the magnetic properties of marine sediments. The chemical principles include those for distinguishing the four major sources of sediments (continental, biological, authigenic/hydrogenous, volcanic/hydrothermal) from one another by determining elemental abundance distributions, as well as for investigating the stabilities of mineral phases relative to changes in pE and pH. The magnetic principles include the effects of authigenesis and diagenesis on ...

1980-05-01

366

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

367

Long-lived states to sustain hyperpolarized magnetization  

UK PubMed Central (United Kingdom)

Major breakthroughs have recently been reported that can help overcome two inherent drawbacks of NMR: the lack of sensitivity and the limited memory of longitudinal magnetization. Dynamic nuclear polarization...Full Text Available

2009-11-03

368

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

369

Epidemiological appraisal of studies of residential exposure to power frequency magnetic fields and adult cancers.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To appraise epidemiological evidence of the purported association between residential exposure to power frequency magnetic fields and adult cancers. METHODS: Literature review and epidemiological...Full Text Available

1996-08-01

370

Epidemiologic studies of electric and magnetic fields and cancer: strategies for extending knowledge.  

UK PubMed Central (United Kingdom)

Epidemiologic research concerning electric and magnetic fields in relation to cancer has focused on the potential etiologic roles of residential exposure on childhood cancer and occupational exposure...Full Text Available

1993-12-01

371

Energetic constraints on the creation of cell membrane pores by magnetic particles.  

UK PubMed Central (United Kingdom)

Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available

1996-08-01

372

Electric and magnetic field exposures for people living near a 735-kilovolt power line.  

UK PubMed Central (United Kingdom)

The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available

1995-09-01

373

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

374

Design of modular coils for a quasi-axisymmetric stellarator with a flexible control of the magnetic field configuration  

Energy Technology Data Exchange (ETDEWEB)

A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a flexibility of the magnetic field configuration is realized. For the case that the rotational transform ...

2002-08-01

375

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

376

A case cohort study of suicide in relation to exposure to electric and magnetic fields among electrical utility workers.  

UK PubMed Central (United Kingdom)

OBJECTIVES--This case cohort study examines whether there is an association between exposure to electric and magnetic fields and suicide in a population of 21,744 male electrical utility workers from...Full Text Available

1996-01-01

377

A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal...  

Science.gov (United States)

Name U.S. Geological Survey A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal Field, Nevada: A Web Site for Distribution of Data by U. S. Geological Survey &...

2011-08-20

378

Stretch-out operation and extended low power operation in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Stretch-Out and Extended Low Power Operation is two particular operating modes applied for nuclear electricity generation. The relevant safety analysis and the impacts on plant operation are well illustrated, as well as some operation experiences earned in Daya Bay nuclear power station. The safety analysis and plant practice show that Stretch-Out operation and Extended Low Power Operation are operable in Daya Bay nuclear power station

2002-10-01

379

Monthly report of activities: APRIL 1, 1969  

Science.gov (United States)

This is the first of a series of monthly reports summarizing the status of the work of the National Accelerator Laboratory. This first report will cover developments since the publication of the Design Report in January. Authorization hearings were held before the Joint Committee on Atomic Energy on February 21, 1968. Dr. Wilson described the plans and designs of the Laboratory. The present plan of the Laboratory is that the Village of Weston will be utilized for office, laboratory, and shop space during construction. The Laboratory business office is already occupying several houses. The linac section is occupying three houses for offices and construction of an 8,000 sq ft laboratory building for linac work is almost complete. Another house is being used and a 4,500 sq ft inflatable building is being constructed for model-magnet and vacuum testing. Other temporary buildings will be constructed for use by other sections. We plan to move into the village as rapidly ...

1968-04-01

380

Untitled - NASA Technical Reports Server  

Science.gov (United States)

the techniques employed at present, some of which, like magnetic forming and hotdrape forming, are in experimental stages. Published October 1965. ...

381

Thermal-physical analysis of low-radioactive thermonuclear plasma in the magnetic fusion device  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

383

The Effect of the Temperature to Which the Material is Heated ...  

Science.gov (United States)

... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...

1980-09-01

386

SELECTED LISTING OF ECHNOLOGY UTILIZATION PUBLICATIONS  

Science.gov (United States)

as magnetic forming and hot-drape forming. Details about the 25 techniques discussed incorporate the most recent improvements and ...

389

Read/write characteristics of focused-ion-beam-etched heads for perpendicular magnetic recording media  

International Nuclear Information System (INIS)

The read/write characteristics for perpendicular magnetic recording media of focused-ion-beam (FIB)-etched recording heads were investigated. It was found that the trailing edge of an FIB-etched head produces a higher gradient in the magnetic field perpendicular to the medium than a head which has not been etched. The signal-to-noise ratio of the medium increased with the FIB-etched write gap. A high-Bs and thin pole increased the magnetic field's gradient in the perpendicular direction, resulting in excellent read/write characteristics.

2001-10-01

390

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

391

Nuclear moments of the 11/2"- isomer in "1"8"7Ir  

International Nuclear Information System (INIS)

... excited states iridium 187 isomeric nuclei magnetic fields nuclear electric

392

Nuclear moments and changes in rms-radii of neutron-deficient silver isotopes  

International Nuclear Information System (INIS)

... nuclear electric moments nuclear magnetic moments nuclear radii quadrupole

1987-03-23

393

Nuclear magnetic resonance on oriented XVTa and XXTa  

Energy Technology Data Exchange (ETDEWEB)

XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.

1984-08-01

394

Nature of the magnetic susceptibility of dysprosium. Paramagnetic susceptibility of dysprosium - yttrium alloys  

International Nuclear Information System (INIS)

The paramagnetic susceptibility of single crystals of dysprosium-yttirum alloys is measured in the basal plane and along the hexagonal axis. It is shown that the susceptibility of the alloys obeys the Curie-Weiss law, the effective magnetic moments allong the different directions being the same and the paramagnetic Curie temperatures being different. The difference between the paramagnetic Curie temperatures in the basal plane and along the hexagonal axis is independent of the dysprosium concentration in the alloy. As a comparison with the theoretical models of magnetic anisotropy shows, this is an indication that the magnetic anisotropy of dysprosium - yttrium alloys is of a single-ion nature.

1976-01-01

395

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

397

Magnetic structure of Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2  

International Nuclear Information System (INIS)

The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).

399

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

400

Magnetic properties of oxovanadium(IV) complexes with bidentate on donor Schiff bases  

International Nuclear Information System (INIS)

(Feb 1977). Japan Syamal, A. Bombay Univ. (India). Univ. Dept. of Chemical

1977-01-01

401

Magnetic phase diagrams of the TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} systems  

Energy Technology Data Exchange (ETDEWEB)

The a.c. susceptibility and high field magnetization of TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} compounds were investigated up to 140 kOe. The (T, x) magnetic phase diagrams were determined. For both systems, an increase in the Pd content causes a decrease in the Neel temperature and changes the magnetization curves. (orig.)

1995-12-01

402

Magnetic braking in weakly ionized media  

International Nuclear Information System (INIS)

The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.

403

Magnetic Tape Pulse Width to Digital Convertor.  

Science.gov (United States)

... This is achieved by the use of a unique logic circuit employing a plurality of flip-flop devices, multivibrators and AND gates. ...

1976-12-07

404

Magnetic Properties of a Material Used to Estimate Elastic and Plastic Strains of Ferrite?Pearlite Steels  

British Library Electronic Table of Contents (United Kingdom)

The effect of elastic and plastic strains on the magnetic properties of ferrite-pearlite steels has been studied. It has been shown that the sensitivity to elastic-tensile and bending strains is four to five times greater for remnant magnetization than for coercive force. In order to determine the degree of cold plastic deformation of high-carbon steels, a two-parametric testing technique based on the use of remnant magnetization and coercive force was suggested. An MMT-2 device was recommended for measurement of the required parameters.

2005-01-01

405

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

409

Injection and extraction magnets: septa  

CERN Document Server

An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.

2010-01-01

410

Influence of resonant US on H-NMR at application of magnetic nanoparticles  

International Nuclear Information System (INIS)

2010 [1 p.] Germany Repp, Felix El-Miladi, Nouri Hoehl, Christian Jahanbakhsh,

2010-03-21

411

From Rodinia to Gondwana: few paleo magnetic constraints; many speculations  

International Nuclear Information System (INIS)

... Trama; Montevideo (Uruguay) 70 p. GEOSCIENCES geologic history geologic

2001-11-12

415

Domain wall pining in a jointed ferromagnetic nano-wire  

Energy Technology Data Exchange (ETDEWEB)

The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.

2004-05-01

419

Conceptual design of a compact medical synchrotron with a hybrid magnet  

International Nuclear Information System (INIS)

English 2001 p. 178 China Iwashita, Y. Kumada, M. National Institute

2001-09-17

420

CAPACITOR DISCHARGE METAL FORMING  

Science.gov (United States)

... Report Date : JUL 1961. Pagination or Media Count : 39. Abstract : Open-ende Terms: Electrohydraulic forming, Magnetic forming. ...

1961-07-01

421

A Profile of Defense Manufacturing Costs and Enabling ...  

Science.gov (United States)

... Casting Explosive forming Forging Electrohydraulic forming Extruding Magnetic forming Rolling Electroforming Drawing Powdered metal forming ...

1992-01-01

422

A GENERAL STUDY OF PROCESSES FOR THE ...  

Science.gov (United States)

... fields, materials can be subjected to energy densities exceeding those realized in high explosives, a fact which forms the basis for magnetic forming ...

1962-11-01

423

Use of magnetic treatment to intensify certain processes in the refining of chemical products of coking  

Energy Technology Data Exchange (ETDEWEB)

The results of the investigations show that magnetic treatment is a quite practical and effective method of intensifying certain technological processes in the coking industry. Magnetic treatment was utilized for improving the production of ammonium sulfate, refining of the naphthalene fraction, removal of sludge from wash oil in the benzol division, and the treatment of tar before fractionation. 2 references, 3 tables.

1983-01-01

424

Stability of superconducting ISABELLE dipole magnets  

Energy Technology Data Exchange (ETDEWEB)

The concept of the minimum propagating zone (MPZ) is used to examine the causes of quenches in ISABELLE cosine theta superconducting dipole magnets. The size of disturbances large enough to exceed the MPZ and initiate quenches is estimated and compared with the size of disturbances which may be produced in the magnets. A suggestion for reducing the size of these disturbances through individual support of the coil block is outlined.

1981-04-01

425

Self-simulating motion of an ionized gas expelled by a magnetic piston  

Energy Technology Data Exchange (ETDEWEB)

The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.

1980-01-01

426

Search for magnetic rotation in {sup 202}Pb and {sup 203}Pb  

Energy Technology Data Exchange (ETDEWEB)

High-spin states in {sup 202}Pb and {sup 203}Pb have been investigated by in-beam {gamma}-ray spectroscopy following the reaction {sup 198}Pt({sup 9}Be,xn). A search for magnetic rotational bands in these isotopes confirmed one of the two bands previously assigned to {sup 202}Pb and revealed a new band in this isotope. No evidence for magnetic rotation has been found in {sup 203}Pb. (orig.)

2000-11-01

427

Multidipole magnetic fields for plasma confinement  

Energy Technology Data Exchange (ETDEWEB)

Plasma confinement by permanent magnets has been studied. An analytic formula for the field of a single bar magnet has been obtained. Generalization to various configurations of multidipole fields has also been found. Any two-dimensional field may now be completely described by a simple function of complex variables in closed form. Vector potential has also been obtained by integrating over a prescribed Riemann surface. The confinement of plasma by multidipole fields then becomes obvious through conservation principles.

1983-07-01

428

Methods of reducing magnetic field near the transmission lines  

International Nuclear Information System (INIS)

Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.

2003-01-01

429

Mean magnetic moments of polycrystalline Ce compounds in a tetragonal crystal field  

International Nuclear Information System (INIS)

An alternative and graphical representation of the magnetic moment and the effective paramagnetic moment for polycrystalline Ce compounds with tetragonal site symmetry is described. The reduced moments can be calculated by means of standard perturbation theory. The calculated values deduced from the ground states of CeCu_2Si_2, CeRu_2Si_2, and CePd_2Si_2 polycrystals are compared with experimental magnetic moments.

430

Magnetic properties of heavy rare-earth tungstates  

International Nuclear Information System (INIS)

Measurement of the magnetic susceptibility of powder samples of heavy rare-earth (Tb, Dy, Ho, Er, Tm and Yb) tungstates have been reported in the temperature range 300 to 900 K. Curie-Weiss law behaviour has been observed for all samples. The Curie constant, paramagnetic Curie temperature and magneton number for the magnetic ions have also been evaluated for each material. (author).

1978-12-01

431

Magnetic properties of FeSi with cobalt impurities  

Energy Technology Data Exchange (ETDEWEB)

Results of experimental researches of impurity level crystals Fe1-xCoxSi are presented in this article. Magnetic properties in a temperature range up to T {<=} 1000 K are analyzed. It was established that with Co impurities increasing origin of magnetic ordering exists at low temperatures. At high temperatures a high temperature maximum of susceptibility of nominally pure iron monosilicide crystal is observed.

2010-01-01

432

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

433

Magnetic and valence transitions in CePd_2_-_xMn_xSi_2:L_I_I_I edge study  

International Nuclear Information System (INIS)

We report on solid solution CePd_2_-_xMn_xSi_2 which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.)).

434

Magnetic and valence transitions in CePd[sub 2-x]Mn[sub x]Si[sub 2]:L[sub III] edge study  

Energy Technology Data Exchange (ETDEWEB)

We report on solid solution CePd[sub 2-x]Mn[sub x]Si[sub 2] which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.))

1994-04-01

435

Kondo effect in the systems of magnetic trimers on a metal surface  

International Nuclear Information System (INIS)

Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)

2010-11-01

436

Invariant correlation functions, superconvergence sum rules, and electric-magnetic duality  

Energy Technology Data Exchange (ETDEWEB)

The gauge-invariant correlation function for the Yang-Mills field strengths is shown to admit a symmetric decomposition into electric and magnetic components. The spectral weights are seen to obey a sum rule of the superconvergence type, owing to asymptotic freedom. The close relation between the dielectric function, electric-magnetic duality, and the algebra of generalized Chern-Simons charges is illustrated for the linearized Yang-Mills-Higgs system.

1988-01-01

437

Instability of 4f and 3d magnetic moments under high pressure  

International Nuclear Information System (INIS)

The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).

438

Heat transfer augmentation using a magnetic fluid under the influence of a line dipole  

Energy Technology Data Exchange (ETDEWEB)

Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...

2004-04-01

439

Heat transfer augmentation using a magnetic fluid under the influence of a line dipole  

International Nuclear Information System (INIS)

Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...

2004-04-01

440

Experimental Verification of the Hall Effect during Magnetic Reconnection in a Laboratory Plasma  

Energy Technology Data Exchange (ETDEWEB)

In this letter we report a clear and unambiguous observation of the out-of-plane quadrupole magnetic field suggested by numerical simulations in the reconnecting current sheet in the Magnetic Reconnection Experiment (MRX). Measurements show that the Hall effect is large in collisionless regime and becomes small as the collisionality increases, indicating that the Hall effect plays an important role in collisionless reconnection.

2005-06-16

441

Effect of heat treatment on the properties of Metglas foils, and laminated magnetoelectric composites made thereof  

British Library Electronic Table of Contents (United Kingdom)

Annealing of magnetostrictive Metglas foils, subsequently incorporated into laminated Metglas/Pb(Zr, Ti)O3 magnetoelectric (ME) composites, is shown to result in improved magnetic properties, as well as ME coefficients. Annealing of the foils at 350 ?C resulted in partial crystallization, without oxidation or magnetic cluster formation that would reduce the magnetization. Laminate composites made with these annealed Metglas foils had improved ME coefficients.

2011-01-01

442

Direct conversion of fusion energy into the electric one in the 'Dragon' magnetic confinement system  

International Nuclear Information System (INIS)

It is shown that recuperator in which the thermal energy of particles is transformed into electric oue under drift in crossed fields is naturally coupled with dragontype magnetic confinement system, so the recuperation process can be initiated in the dragon magnetic field. A number of questions occuring under analysis of recuperator-dragon system is considered, including the dynamics of particle transfer to the recuperator, the share of particles entering the recuperator, the effect of rotational transform and the recuperation efficiency.

443

Current applications of magnetic resonance in coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)

1982-01-01

444

Conductance quantization in ferromagnetic Ni nano-constriction  

Energy Technology Data Exchange (ETDEWEB)

The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.

2002-02-01

445

Comment on 'Magnetic braking revisited: activities for the undergraduate laboratory'  

International Nuclear Information System (INIS)

Here, we consider a recent paper concerned with magnetic braking by induced currents (Ireson and Twidle 2008 Eur. J. Phys. 29 745-51). Our objective is to elucidate why measurement of speed in which a magnet is dropped through a non-ferromagnetic conductive tube depends on its geometry in a non-monotonic way, which was not clearly explained by the authors. (letters and comments)

2009-03-01

446

Bacterial cultivation in high magnetic fields by 7-tesla superconducting magnet; 7T chodendo magnet ni yori hasseishita kojiba ni okeru biseibutsu no baiyo  

Energy Technology Data Exchange (ETDEWEB)

Although a large number of studies on effects of magnetic fields on living organisms was reported, no definite results were obtained in many cases because the related conditions are non-uniform and uncertain, such that the uniform magnetic space is smaller than test samples, and temperature control is insufficient. Therefore, the present study developed a microorganism cultivation system that is applied with a 7-T superconducting magnet. This system has the following features: it generates homogeneous magnetic fields of 0.5 to 7 T {plus_minus} 0.5% in the space with a diameter of 100 mm and a length of 200 mm in a normal temperature bore (with a diameter of 160 mm); it can cultivate microorganisms aerobically at temperatures of 10 to 70{degree}C {plus_minus} 0.1{degree}C; it can perform the cultivation simultaneously with a control cultivation in a small magnetic field weaker than ...

1994-12-20

447

Ab initio calculations in a uniform magnetic field using periodic supercells  

Energy Technology Data Exchange (ETDEWEB)

We present a formulation of ab initio electronic structure calculations in a finite magnetic field, which retains the simplicity and efficiency of techniques widely used in first principles molecular dynamics simulations, based on plane-wave basis sets and Fourier transforms. In addition we discuss results obtained with this method for the energy spectrum of interacting electrons in quantum wells, and for the electronic properties of dense fluid deuterium in a uniform magnetic field.

2003-10-21

448

X-ray magnetic form factor of UTe  

Energy Technology Data Exchange (ETDEWEB)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

1995-07-01

449

X-ray magnetic form factor of UTe  

International Nuclear Information System (INIS)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

450

Transition-metal dimers and physical limits on magnetic anisotropy  

British Library Electronic Table of Contents (United Kingdom)

Recent advances in nanoscience have raised interest in the minimum bit size required for classical information storage. This bit size is determined by the necessity for bistability with suppressed quantum tunnelling and energy barriers that exceed ambient temperatures. In the case of magnetic information storage, much attention has centred on molecular magnets with bits consisting of about 100 atoms, magnetic uniaxial anisotropy energy barriers of about 50?K and very slow relaxation at low temperatures. Here, we draw attention to the remarkable magnetic properties of some transition-metal dimers, which have energy barriers approaching 500?K with only two atoms. The spin dynamics of these ultrasmall nanomagnets is strongly affected by a Berry phase, which arises from quasi-degen...

2007-01-01

451

The addition of trim coils to the Tandem Mirror Experiment magnet system to improve the magnetic field mapping  

International Nuclear Information System (INIS)

The mapping of the magnetic flux bundle from the center cell to the Plasma Potential Control plates (PPC) on the end fan of the Tandem Mirror Experiment Upgrade (TMX-U), was improved by the addition of trim coils (12,000 amp-turns) on each side of each end fan next to the pump beam magnetic shields. The coils' axes are oriented perpendicular to the machine centerline. These coils made the necessary corrections to the field-line mapping, while keeping the field in the nearby pump beam magnetic shield below the saturation threshold. This paper briefly describes the problem, discusses the design as it evolved, and presents the results of the field testing. A brief description of the improvement in the machine performance is also included.

452

Novelty, preparation, characterization and enhancement of magnetic properties of Mn nanoferrites using safety binder (egg white)  

British Library Electronic Table of Contents (United Kingdom)

Nanocrystalline MnFe"2O"4 ferrite was prepared by using autocombustion technique (flash). The microstructure and magnetic properties are studied. The results of XRD and TEM clarified that, this ferrite is nanosized with particle size (39 nm). Magnetic measurements showed a ferromagnetic behavior with T"C = 613 K, the saturation magnetization M"s = 13.71 emu/g, remanent magnetization M"r = 0.1694 emu/g and, coercivity H"c = 25.6 Oe. Natural material, egg white used as an aqueous medium to extend prepare nanoparticles better than other chemical interesting materials.

2011-01-01

453

Magnetic Moments and Electromagnetic Radii of Nucleon and ?(1232) in an Extended Goldstone-Boson-Exchange Model  

International Nuclear Information System (INIS)

We derive the exchange currents of pseudoscalar, vector, and scalar mesons from Feynman diagrams, and use them to calculate the magnetic form factors of nucleon and ?(1232). The magnetic moments and electromagnetic radii are obtained by using those form factors and the parameters determined from the masses of nucleon and ?(1232). We find the magnetic moments and electromagnetic radii of nucleon and ?(1232) can be produced very well in the extended Goldstone-Boson-exchange model in which all of pseudoscalar, vector, and scalar meson nonet are included. The magnetic moments of ?(1232) are closer to experiment values and results from lattice calculation than the results obtained by the model without other mesons except for pion and sigma.

2005-01-15

454

Lorentz transmission electron microscopy investigation of magnetically patterned Co/Pt multilayers  

Energy Technology Data Exchange (ETDEWEB)

The switching behavior of magnetic patterns prepared by ion irradiation was investigated. Co/Pt multilayers with perpendicular anisotropy and large out-of-plane coercivities 5-6 kOe were grown on electron transparent SiN windows. Regularly spaced 1 micron sized regions, were magnetically pattered via ion beam irradiation through a stencil mask. Lorentz TEM was used to observe in-situ magnetization reversal processes of irradiated regions under well-defined applied magnetic fields. When the in-plane field was increased, domain wall motion was observed, resulting in the alignment of the patterns with the direction of the applied field. The switching mechanism of the in-plane patterns was by domain wall motion.

2000-08-01

455

Development of the SSC (Superconducting Super Collider) trim coil beam tube assembly  

Energy Technology Data Exchange (ETDEWEB)

The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.

1987-01-01

456

Crossover of the magnetic levels and adiabatic magnetization of the mesoscopic cluster V15  

British Library Electronic Table of Contents (United Kingdom)

The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...

2006-01-01

457

Application of GIS for the evaluation of human exposure to magnetic field in the vicinity of power lines  

Energy Technology Data Exchange (ETDEWEB)

Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.

1998-10-01

458

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have ...

2002-07-01

460

Sustaining Operational Maneuver in the Twenty-First Century  

Science.gov (United States)

... and the Commonwealth forces launched Operation GOODWOOD in an attempt to break through the German lines. In the ...

2010-05-13

461

Safe operation of research reactors and critical assemblies code of practice and annexes  

CERN Document Server

Safe operation of research reactors and critical assemblies

1984-01-01

462

Magnetic properties of laminated perovskite-like ferroelectromagnetics  

International Nuclear Information System (INIS)

Magnetic properties of layer ferromagnets against the thickness are investigated. Two new compounds served for studies: Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1. The Moessbauer effect and the magnetic susceptibility measurements were applied in the experiment. The Faraday method was used in magnetic measurements in fields from 1 to 9,5 kOe. The results of Moessbauer measurements show that temperature dependence of the spectra is typical for compounds with superparamagnetic properties. The magnetic fields Hsub(n) on Fe"5"7 nuclei in Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1 are similar and equal to 520+-10 kOe. Therefore it may be concluded that relaxation times of nuclear spins in these compounds are equal or close to each other. The lines of quadrupole splitting appear in spectra together at 20 K. The results of magnetic ...

1975-01-01

463

Ramp-rate sensitivity of SSC dipole magnet prototypes  

Energy Technology Data Exchange (ETDEWEB)

One of the major achievements of the magnet R&D program for the Superconducting Super Collider (SSC) is the fabrication and test of a series of 20 5-cm aperture, 15-m long dipole magnet prototypes. The ramp rate sensitivity of these magnets appears to fall in at least two categories that can be correlated to the manufacturer and production batch of the strands used for the inner-coil cables. The first category, referred to as type-A, is characterized by a strong quench current degradation at high ramp rates, usually accompanied by large distortions of the multipole fields and large energy losses. The second category, referred to as type-B, is characterized by a sudden drop of quench current at low ramp rates, followed by a much milder degradation at larger rates. The multipole fields of the type-B magnets show little ramp-rate sensitivity, and the energy losses are smaller than for the type-A ...

1994-07-01

464

Magnetization and 61Ni Moessbauer effect study of the ternary arsenide CrNiAs  

International Nuclear Information System (INIS)

The results of x-ray diffraction, dc magnetization, and 61Ni Moessbauer spectroscopy studies of the ternary arsenide CrNiAs are reported. This compound crystallizes in the orthorhombic Fe2P-type structure (space group P6-bar2m) with the lattice parameters a 6.1128(2) A and c = 3.6585(1) A. CrNiAs is a mean-field ferromagnet with Curie temperature TC = 171.9(1) K and the critical exponents ? 0.514(18), ? = 1.010(16), and ? = 2.922(10). The temperature dependence of the magnetic susceptibility above TC follows the modified Curie-Weiss law with a paramagnetic Curie temperature of 176.0(3) K and effective magnetic moment per transition metal atom of 2.42(1) ?B. The magnetic moment per formula unit at 4.2 K is found to be 1.114(33) ?B. The hyperfine magnetic field at 61Ni nuclei at 4.2 K of 41.5(1.0) kOe implies that the Ni atoms carry a magnetic moment of 0.15(3) ...

2008-08-13

465

Magnetic microstructure of candidates for epitaxial dual Heusler magnetic tunnel junctions  

Energy Technology Data Exchange (ETDEWEB)

Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.

2009-05-15

466

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were ...

2001-04-01

467

Low-temperature properties of ternary magnetic rare-earth transition-metal germanides with the Sc sub 5 Co sub 4 Ge sub 10 -type structure  

Energy Technology Data Exchange (ETDEWEB)

DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque on the ...

1988-01-01

468

Low temperature properties of ternary magnetic rare earth transition metal germanides with the Sc/sub 5/Co/sub 4/Ge/sub 10/-type structure  

Energy Technology Data Exchange (ETDEWEB)

DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the crystal field torque ...

1988-07-01

469

Visualization of direct contact heat transfer between water and molten alloy  

Energy Technology Data Exchange (ETDEWEB)

We have been developing an innovative Steam Generator concept of Fast Breeder Reactors by using liquid-liquid direct contact heat transfer. In this concept, the SG shell is filled with a molten alloys, which is heated by primary sodium. Water is fed into the high temperature molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information to discuss the heat transfer mechanisms of the direct contact between the water and the alloy, this phenomenon was visualized by real-time neutron radiography. JRR-3M real-time thermal neutron radiography in Japan Atomic Energy Research Institute was used. Followings are main results. (1) The vigorous evaporation occurs in the molten alloy. This phenomena is different from the known phenomenon such as the evaporation of refrigerant R-113 in the water. (2) The evaporation in the bubble has finished in a moment due to high heat transfer performance between the liquid and molten alloy. (3) It is ...

1996-06-01

470

USE OF A CONTROLLED CHLORINE DIOXIDE (CLO2) RELEASE SYSTEM IN COMBINATION WITH MODIFIED ATMOSPHERE PACKAGING (MAP) TO CONTROL THE GROWTH OF PATHOGENS  

British Library Electronic Table of Contents (United Kingdom)

Abstract Salmonella Typhimurium and Listeria monocytogenes are major bacterial pathogens associated with poultry products. A controlled released ClO2 sachet applied with modified atmosphere packaging (MAP) was evaluated for its ability to control the growth of S. Typhimurium and L. monocytogenes on raw chicken breast during refrigerated storage. The fresh chicken samples were inoculated with one or the other of the pathogens at 104-cfu/g, and the packages (with and without ClO2 sachet) were flushed with ambient air or 30% CO2/70% N2 before sealing, and then stored at 4C for up to 21 days. The maximum reduction in MAP plus ClO2 (compared with MAP alone) was 0.68-log-cfu/g for S. Typhimurium and 1.87-log-cfu/g for L. monocytogenes. Color and pH changes of the chicken breast were observed at ...

2011-01-01

471

Time-Resolved Aerosol Collector for CCSEM/EDX Single Particle Analysis  

Energy Technology Data Exchange (ETDEWEB)

An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 Air Quality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the relative contribution of non-volatile ...

2003-01-02

472

The national plan of fight against greenhouse effect; Le plan national de lutte contre l'effet de serre  

Energy Technology Data Exchange (ETDEWEB)

France has committed herself to keep in 2010 the same levels of greenhouse gas emissions as those of 1990, i.e. 144 millions of tons of carbon equivalent (MtCe). However, taking into account the existing pollution abatement measures and the measurements performed so far, the greenhouse gases level should reach 160 MtCe in 2010. Therefore, the inter-ministry commission on greenhouse effect decided on November 27, 1998 to elaborate a new national plan of fight against greenhouse effect. The elaboration of the new plan has fallen under the responsibility of the inter-ministry mission of greenhouse effect (MIES). The new plan was presented by the prime minister, L. Jospin, on January 19, 2000. This document summarises the content of the new plan: architecture (modalities of elaboration, content), measures for the reduction of greenhouse gas emissions (industry, transportation sector, buildings, agriculture-forestry, wastes valorization, development of renewable energies, ...

2000-07-01

473

System suitable for use in neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate thermal neutrons from ...

1990-02-07

474

System suitable for use in neutron radiography  

International Nuclear Information System (INIS)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate thermal neutrons from ...

1988-07-20

475

Synchrotron resource of the Howard Hughes Medical Institute  

Energy Technology Data Exchange (ETDEWEB)

The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to first serve as a monitor of the white ...

1989-07-01

476

Pumps and compressors - buyers` guide 1996/`97; Pumpen und Kompressoren - Einkaufsfuehrer 1996/97  

Energy Technology Data Exchange (ETDEWEB)

The 1996/`97 buyers` guide comprises ten chapters: 1. List of suppliers; 2. Waste management, effluents, sewage systems; 3. Water supply, hydroengineering; 4. Chemistry, petrochemistry; 5. Chemical engineering; 6. Food industry, biotechnology; 7. Paper and cellulose industry; 8. Natural gas industry, natural gas supply; 9. Power plant engineering, power systems, district heating; 10. Air conditioning and refrigeration engineering. (orig.) [Deutsch] Der vorliegende Einkaufsfuehrer 1996/97 ist in zehn Kapiteln gegliedert. Diese sind: 1. Firmenverzeichnis 2-11 2. Entsorgungs-/Abwassertechnik, Klaeranlagen 12-15 3. Wasserversorgung, Wassertechnik 16-18 4. Chemie, Petrochemie 19-22 5. Verfahrenstechnik 23-26 6. Lebensmittelindustrie, Biotechnik 27-29 7. Papier-, Zeluloseindustrie 30-31 8. Erdgasindustrie, -versorgung 32 9. Kraftwerkstechnik, Energieanlagen, Fernwaerme 33-34 10. Kaelte-/Klimatechnik 35-36. (orig.)

1996-12-01

477

Prediction of critical properties of mixtures from the PRSV-2 equation of state: A correction for predicted critical volumes  

Energy Technology Data Exchange (ETDEWEB)

Critical properties of a fluid or fluid mixtures are important for describing fluid phase behavior, predicting physical properties, developing equations of state, and designing supercritical-fluid extraction processes, and compression and refrigeration units. The predictive capability of the Peng-Robinson-Styjek-Vera (PRSV-2) equation of state (1986) for critical properties of binary mixtures was investigated. The procedure adopted by Heidemann and Khalil (1980) and discussed by Abu-Eishah et al. (1998) was followed. An optimized value for the binary interaction parameter based on minimization of error between experimental and predicted critical temperatures was used. The standard and the average of the absolute relative deviations in critical properties are included. The predicted critical temperature and pressure for several nonpolar and polar systems agree well with experimental data and are always better than those predicted by the group-contribution method. A ...

1999-09-01

478

Performance analysis on a hybrid air-conditioning system of a green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system at a latent load of 30% and this improving can be achieved by 73.8% at a 42% latent load. The optimal ratio of adsorption ...

2006-05-15

479

Irradiation of spices, packaging materials and luncheon to improve the storability of the end product  

International Nuclear Information System (INIS)

Spices and packaging materials were exposed to gamma irradiation at a dose of 10 KGy. Luncheon was prepared with irradiated or non-irradiated spices. Prepared luncheon was packaged in irradiated or non-irradiated packaging materials. Packaged luncheon was treated with 2 KGy. Treated and untreated packaged luncheon were kept in a refrigerator (1-4 Centigrade) for 12 months. Microbiological, nutritive and chemical characteristics of luncheon were evaluated after processing and during storage; whereas, sensory quality was evaluated only after irradiation. Gamma irradiation decreased the microorganisms counts of spices, packaging materials and packed luncheon and increased the shelf-life of packaged luncheon products. No major differences in moisture, protein, fat, ph value, total acidity, lipid peroxide and volatile basic nitrogen were observed due to irradiation. Sensory evaluation showed that all the combination treated luncheon were acceptable regarding sensory ...

480

Integration and Testing of the Micro-X Rocket Payload  

Science.gov (United States)

The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets include the core of the Virgo cluster and ...

2011-05-01

481

Influence of gamma irradiation and storage on the microbial load, chemical and sensory quality of chicken kabab  

Energy Technology Data Exchange (ETDEWEB)

Influence of gamma irradiation and storage on the microbial load, chemical and sensory quality of chicken kabab was investigated. Chicken kabab was treated with 0, 2, 4 or 6 kGy doses of gamma irradiation. Treated and untreated samples were kept in a refrigerator (1-4 deg. C). Microbiological, chemical and sensory characteristics of chicken kabab were evaluated at 0-5 months of storage. Gamma irradiation decreased the microbial load and increased the shelf-life of chicken kabab. Irradiation did not influence the major constituents of chicken kabab (moisture, protein and fats). No significant differences (p>0.05) were observed for total acidity between non-irradiated (control) and irradiated chicken kabab. Thiobarbitric acid (TBA) values (expressed as mg malonaldehyde (MDA)/kg chicken kabab) and volatile basic nitrogen (VBN) in chicken kabab were not affected by the irradiation. Sensory evaluation showed no significant differences between irradiated and ...

2010-08-15

482

Development and Application of Subchannel Analysis Code Technology for Advanced Reactor Systems  

Energy Technology Data Exchange (ETDEWEB)

A study has been performed for the development and assessment of a subchannel analysis code which is purposed to be used for the analysis of advanced reactor conditions with various configurations of reactor core and several kinds of reactor coolant fluids. The subchannel analysis code was developed on the basis of MATRA code which is being developed at KAERI. A GUI (Graphic User Interface) system was adopted in order to reduce input error and to enhance user convenience. The subchannel code was complemented in the property calculation modules by including various fluids such as heavy liquid metal, gas, refrigerant,and supercritical water. The subchannel code was applied to calculate the local thermal hydraulic conditions inside the non-square test bundles which was employed for the analysis of CHF. The applicability of the subchannel code was evaluated for a high temperature gas cooled reactor condition and supercritical pressure conditions with water and Freon. A ...

2006-01-15

483

Analyses of mixed-hydrocarbon binary thermodynamic cycles for moderate-temperature geothermal resources  

Energy Technology Data Exchange (ETDEWEB)

A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately-low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5 MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. These fluorocarbons, ...

1981-02-01

484

Activity of Citrus Essential Oils against-Escherichia coli-O157:H7 and-Salmonella-spp. and Effects on Beef Subprimal Cuts under Refrigeration  

British Library Electronic Table of Contents (United Kingdom)

Abstract:- Escherichia coli-O157:H7 and-Salmonella-spp. are bacterial pathogens often associated with beef, and cause many cases of foodborne illness each year in the United States. During beef slaughter and processing, these bacteria may spread from the hide or intestines to the carcass. The objective of this research was to investigate the use of naturally occurring compounds citrus essential oils (CEOs) extracted from orange peel to reduce or eliminate these pathogens at the chilling stage of processing, or during fabrication. Brisket flats (used to simulate beef subprimals) were spot inoculated with approximately 6 log of surrogate generic-E. coli-cocktail (previously shown to be identical in growth and survival parameters to-E. coli-O157:H7 and-Salmonella-spp.). Following drying, CEOs...

2011-01-01

485

Kootenai River Nutrient Dosing System and N-P Consumption: Year 2008.  

Science.gov (United States)

In early 2006 we designed and built low energy consumption, pump-operated system, for dosing of the liquid nutrient in the summer 2006 season. This operated successfully, and the system was used again during the 2007 and 2008 seasons for dosing. During the early winter period, 2008, laboratory tests were made of the liquid nutrient pump system, and it was noted that small amounts of air were being entrained on the suction side of the pump, during conditions when the inlet pressure was low. It was believed that this was the cause of diurnal fluctuations in the flow supplied, characteristic of the 2007 year flow data. Replacement of '0' rings on the inlet side of the pumps was the solution to this problem, and when tested in the field during the summer season, the flow supplied was found to be stable. A decision was made by the IKERT committee at the meeting of 20th to 21st May 2008 (held in Coeur d'Alene, Idaho) to use ...

2009-02-19

486

Weld integrity of the superconducting cable aluminium jackets of W7-X  

Energy Technology Data Exchange (ETDEWEB)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, and during operation ...

2009-06-15

487

Weld integrity of the superconducting cable aluminium jackets of W7-X  

International Nuclear Information System (INIS)

The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, and during operation ...

2009-06-01

488

The use of short-echo-time {sup 1}H MRS for childhood cerebellar tumours prior to histopathological diagnosis  

Energy Technology Data Exchange (ETDEWEB)

Proton magnetic resonance spectroscopy (MRS) measures concentrations of metabolites in vivo and provides a powerful method for identifying tumours. MRS has not entered routine clinical use partly due to the difficulty of analysing the spectra. To create a straightforward method for interpreting short-echo-time MRS of childhood cerebellar tumours. Single-voxel MRS (1.5-T Siemens Symphony NUM4, TR/TE 1,500/30 ms) was performed at presentation in 30 children with cerebellar tumours. The MRS results were analysed for comparison with histological diagnosis. Peak heights for N-acetyl aspartate (NAA), creatine (Cr), choline (Cho) and myo-inositol (mIns) were determined and receiver operator characteristic curves used to select ratios that best discriminated between the tumour types. The method was implemented by a group of clinicians and scientists, blinded to the results. A total of 27 MRS studies met the quality control criteria. NAA/Cr >4.0 ...

2007-11-15

489

The electrical measurement of AC losses in a three-phase tri-axial superconducting cable  

International Nuclear Information System (INIS)

In a three-phase tri-axial cable, the magnetic interaction between the phases makes the loss measurement by an electromagnetic method very complex. We developed the theoretical background showing that three-phase AC loss measurements by the electromagnetic method are, in principle, possible. We then implemented this theory in practical measurements on a 3 m long, tri-axial cable fabricated from RABiTS (rolling-assisted biaxially textured substrate) coated conductor. Initially, the proposed measurement technique was implemented in the simpler cases when the three cable phases are 180"0 out of phase, i.e. (0"0, 180"0, 360"0) or (0"0, 360"0, 180"0) rather than (0"0, 120"0, 240"0) as in a traditional three-phase system. For these cases, the currents in the phases are either in phase (360"0 phase difference) or anti-phase (180"0 phase difference). These are essentially single-phase measurements with only one transport current used as the supply for all three phases. ...

2010-09-01

490

Resolution studies of a GEM-based TPC  

Energy Technology Data Exchange (ETDEWEB)

Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the hodoscope allows systematic studies of the homogeneity of the ...

2006-12-15

491

Radiation testing of organic ion exchange resins  

International Nuclear Information System (INIS)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total absorbed dose ...

1983-04-11

492

Radiation testing of organic ion exchange resins  

Energy Technology Data Exchange (ETDEWEB)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup 60}Co source to a total ...

1995-09-01

493

Methods and results for calibration and track separation of a GEM based TPC using an UV-laser  

Energy Technology Data Exchange (ETDEWEB)

In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to be able to identify ...

2008-12-15

494

Hybrid apparatus for Bose-Einstein condensation and cavity quantum electrodynamics: Single atom detection in quantum degenerate gases  

International Nuclear Information System (INIS)

We present and characterize an experimental system in which we achieve the integration of an ultrahigh finesse optical cavity with a Bose-Einstein condensate (BEC). The conceptually novel design of the apparatus for the production of BECs features nested vacuum chambers and an in vacuo magnetic transport configuration. It grants large scale spatial access to the BEC for samples and probes via a modular and exchangeable ''science platform.'' We are able to produce 87Rb condensates of 5x106 atoms and to output couple continuous atom lasers. The cavity is mounted on the science platform on top of a vibration isolation system. The optical cavity works in the strong coupling regime of cavity quantum electrodynamics and serves as a quantum optical detector for single atoms. This system enables us to study atom optics on a single particle level and to further develop the field of quantum atom optics. We describe the technological modules and the ...

2006-06-01

495

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic reference deviations between phantoms and ...

2010-11-21

496

Design of a propulsion system with double-layer power capacitors and soft-switched converters for a hybrid automobile  

Energy Technology Data Exchange (ETDEWEB)

This thesis examines the design of a propulsion system for a series hybrid vehicle and includes the study of an energy storage unit using double-layer capacitors and a lightweight soft-switched converter system, and two new components in series hybrid vehicles. The development of environmentally sustainable vehicles is more urgent now given the fact that pollution levels are ever increasing. No electric vehicle has yet been developed that can compete with a normal vehicle based only on internal combustion engines. The dilemma lies in the difficulty of storing the amount of energy needed and supply it a high power levels. An attractive and viable option to reducing pollution and maintaining good performance may lie in hybrid electric-powered vehicles. The double-layer power capacitors are an interesting option because of their high power density and long lifetime. The devices are new and assembling large energy storage units must be thoroughly examined before using them in actual ...

2001-07-01

497

A high-power millimeter-wave sheet beam free-electron laser amplifier  

International Nuclear Information System (INIS)

The results of experiments with a short period (9.6 mm) wiggler sheet electron beam (1.0 mm x 2.0 cm) millimeter-wave free electron laser (FEL) amplifier are presented. This FEL amplifier utilized a strong wiggler field for sheet beam confinement in the narrow beam dimension and an offset-pole side-focusing technique for the wide dimension beam confinement. The beam analysis herein includes finite emittance and space-charge effects. High-current beam propagation was achieved as a result of extensive analytical studies and experimental optimization. A design optimization resulted in a low sensitivity to structure errors and beam velocity spread, as well as a low required beam energy. A maximum gain of 24 dB was achieved with a 1-kW injected signal power at 86 GHz, a 450-kV beam voltage, 17-A beam current, 3.8-kG wiggler magnetic field, and a 74-period wiggler length. The maximum gain with a one-watt injected millimeter-wave power was observed to be over 30 dB. The ...