WorldWideScience
1

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes ...

1995-12-31

3

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. ...

2007-06-15

5

High Tc superconducting magnetic multivibrators for fluxgate magnetic-field sensors  

Science.gov (United States)

Sensitive and quick-response nonlinear inductance characteristics are found for high Tc superconducting (YBa/sub 2/Cu/sub 3/O/sub 7-chi/) disk cores at 77K in which soft magnetic BH hysteresis loops are observed. Various quick response magnetic devices such as modulators, amplifiers and sensors are built using these cores. The magnetizing frequency can be set to more than 20 MHz, which is difficult for conventional ferromagnetic bulk materials such as Permalloy amorphous alloys and ferrite. New quick-response fluxgate type magnetic-field sensors are made using ac and dc voltage sources. The former is used for second-harmonic type sensors, while the latter is for voltage-output multivibrator type sensors. Stable and quick-response sensor characteristics were obtained for two-core type multivibrators.

1989-09-01

6

International Symposium on Magnetic Suspension Technology. Part 2  

International Nuclear Information System (INIS)

In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.

1991-08-19

7

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

8

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

9

Design of the electromagnetic fluctuations diagnostic for MFTF-B  

Energy Technology Data Exchange (ETDEWEB)

The Electromagnetic Fluctuations (EMF) diagnostic will be used to monitor ion fluctuations which could be unstable in MFTF-B. Each probe assembly includes a high impedance electrostatic probe to measure potential fluctuations, and a group of nested, single turn loops to measure magnetic fluctuations in three directions. Eventually, more probes and loops will be added to each probe assembly for making more detailed measurements. The sensors must lie physically close to the plasma edge and are radially positionable. Also, probes at separate axial locations can be positioned to connect along the same magnetic field line. These probes are similar in concept to the rf probes used on TMX, but the high thermal load for 30-second shots on MFTF-B requires a water-cooled design along with temperature monitors. Each signal channel has a bandwidth of .001 to 150 MHz and is monitored by up to four different data ...

1983-11-28

10

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

11

Nano photonic sensors for microdamage detection : an exploratory simulation.  

Energy Technology Data Exchange (ETDEWEB)

Nano photonic materials are synthetically manufactured crystals at the nano scale with the target of creating a microstructure with a special electro-magnetic periodicity. Such nano photonic materials have the ability to control light propagation and thus are capable of creating photonic bandgaps in the frequency domain. We propose using nano photonic crystals as sensors to detect microdamage in composite materials. We demonstrate using a simulation model that a nano photonic sensor attached to a composite bar experiences a significant change in its bandgap profile when damage is induced in the composite bar. The model predicts the frequency response of the nano photonic sensor using the transfer matrix method. A damage metric to evaluate the change in the frequency response is developed. Successful developments of nano photonic sensors allow damage identification at scales not ...

2005-04-01

12

Development of in-vessel type control rod drive mechanism for marine reactor  

Energy Technology Data Exchange (ETDEWEB)

A highly reliable control rod drive mechanism (CRDM) installed inside the reactor vessel has developed for use of an advanced marine reactor. This CRDM contributes to compactness and simplicity of the reactor system, and it can eliminate the possibility of a rod ejection accident. The CRDM works in the high temperature and high pressure water - 310degC and 12 MPa, the same atmosphere as the primary loop. Driving force is produced by a synchronous motor with the rotor of a permanent magnet, which has been developed. An innovative latch mechanism using separable ball nuts can latch driving shaft connecting the control rod and de-latch it for scram. The rod position detector using a magnetostrictive wire type sensor on the principle of Wiedeman effect has been developed, accuracy of which is verified to have a detecting error within 1.2 mm. Ball bearings for thrust and radial supports in rotation have been developed to be ...

2001-07-01

13

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were ...

2011-09-01

14

Toll-like receptor 2 polymorphism and gram-positive bacterial infections after liver transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract Toll-like receptor 2 (TLR2) is an immune sensor for gram-positive bacterial cell wall components. Single-nucleotide polymorphisms (SNPs) in the TLR2 gene that impair its function may, therefore, influence the risk and outcomes of gram-positive bacterial infections. In a cohort of 694 liver transplant recipients, we assessed the TLR2 SNP that is translated into an amino acid substitution of arginine for glutamine at position 753 (R753Q), and we found that its presence was associated with the clinical characteristics and outcomes of gram-positive bacterial infections. The proportions of patients with the TLR2 R753Q SNP did not significantly differ between those with gram-positive bacterial infections and those without gram-positive bacterial infections (9.6% versus 9.6%, P = 0.999)....

2011-01-01

15

Investigation of the magnetic field response from eddy current inspection of defects  

British Library Electronic Table of Contents (United Kingdom)

Eddy current testing is one of the most widely used methods in non-destructive testing for the inspection of conductive materials. Numerical modelling of eddy current testing has emerged as an important approach alongside experimental studies. This paper investigates an application of numerical modelling and experimental study as a means of the quantitative non-destructive evaluation (QNDE) of defects in conductive samples. There are two methods of measuring eddy current response, more commonly by measuring the change in impedance of the eddy current probe coil, or as used in this work, by measuring the change in magnetic field directly using magnetic field sensors such as superconducting quantum interference devices, giant magneto resistance, or as in this case Hall sensors. Specifically,...

2011-01-01

16

Functionalized magnetic nanoparticle with poly(3-thiopheneacetic acid) and its application for electrogenerated chemiluminescence sensor  

British Library Electronic Table of Contents (United Kingdom)

Polymer-coated magnetic nanoparticles (MNPs) have been prepared and used as an immobilization matrix for the fabrication of solid-state tris(2,2prime-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor. The pre-synthesized maghemite (g-Fe2O3) MNPs were coated with poly(3-thiopheneacetic acid) based on an oxidative polymerization method using KMnO4. The poly(3-thiopheneacetic acid)-coated MNPs have formed the clusters with average diameter of 200-500nm. The multilayer films of poly(3-thiopheneacetic acid)-coated MNPs were uniformly formed on the surface of a Pt electrode by an external magnet. The Ru(bpy)32+ was rapidly incorporated into the multilayer films within 5min through the electrostatic interaction between the Ru(bpy)32+ and the negatively charged c...

2009-01-01

17

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We ...

2005-04-01

18

Magnetic nanoparticle detection using nano-SQUID sensors  

International Nuclear Information System (INIS)

We demonstrate detection of a single core-shell magnetite-silica nanoparticle (outer diameter #approx#120 nm, moment #approx#10"4#mu#_B) using an Nb dc superconducting quantum interference device (SQUID) with the loop size of 350 nm operational at T < 10 K. The system noise was minimized down to 0.2 #mu##PHI#_0 Hz"-"1"/"2 using a cryogenic SQUID series array pre-amplifier. Initial measurements of an individual magnetic nanoparticle were performed and a clear change of the noise spectra of the nano-SQUID was detected at low frequencies in the presence of the nanoparticle. Similar behaviour was confirmed with an FePt nanoparticle with a larger magnetic moment (diameter #approx#150 nm, moment #approx#10"6#mu#_B). Thus, we demonstrate a magnetic sensor based on a dc nano-SQUID and enabling detection of small moments (potentially down to a few electron spins). Such a sensor is of ...

2010-12-01

19

Freeze protection valve for solar heaters  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a solar heater freeze protection valve apparatus comprising in combination: a valve housing; a remote sensor operatively connected to the valve housing from a remote position, the remote sensor including a bulb containing a liquid adapted to compress and expand with the temperature adjacent the bulb; a piston located in the valve body and slidable responsive to expansion and contraction of the liquid in the remote sensor; a first valve element located in the valve housing and attached to the valve piston for movement; a second valve element located in the valve housing and attached to the housing; a first valve seat in the second valve element forming an opening; a second valve seat positioned in a water passageway to allow the flow of fluid when the second valve element is in an open position and to cut off the flow of fluid when the ...

1987-07-21

20

Nondestructive Technique Survey for Assessing Integrity of Composite Firing Vessel  

Energy Technology Data Exchange (ETDEWEB)

The repeated use and limited lifetime of a composite tiring vessel compel a need to survey techniques for monitoring the structural integrity of the vessel in order to determine when it should be retired. Various nondestructive techniques were researched and evaluated based on their applicability to the vessel. The methods were visual inspection, liquid penetrant testing, magnetic particle testing, surface mounted strain gauges, thermal inspection, acoustic emission, ultrasonic testing, radiography, eddy current testing, and embedded fiber optic sensors. It was determined that embedded fiber optic sensor is the most promising technique due to their ability to be embedded within layers of composites and their immunity to electromagnetic interference.

2000-08-01

21

Sensor test facilities and capabilities at the Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories has recently developed two major field test capabilities for unattended ground sensor systems at the Department of energy`s Nevada Test Site (NTS). The first capability utilizes the NTS large area, varied terrain, and intrasite communications systems for testing sensors for detecting and tracking vehicular traffic. Sensor and ground truth data can be collected at either of two secure control centers. This system also includes an automated ground truth capability that consists of differential Global Positioning Satellite (GPS) receivers on test vehicles and live TV coverage of critical road sections. Finally there is a high-speed, secure computer network link between the control centers and the Air Force`s Theater Air Command and Control Simulation Facility in Albuquerque NM. The second capability is Bunker 2-300. It is a facility for evaluating advanced ...

1996-12-31

22

Reborn quadrant anode image sensor  

International Nuclear Information System (INIS)

We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50?m and count rates up to one million events per second.

2009-06-01

23

Reborn quadrant anode image sensor  

British Library Electronic Table of Contents (United Kingdom)

We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial...

2009-01-01

24

Magnetic fluctuations in paramagnetic Mn{sub 0.81}Ni{sub 0.19}  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluctuations present in the paramagnetic Mn{sub 0.81}Ni{sub 0.19} system have been investigated by measuring inelastic magnetic neutron scattering from a single crystal at temperatures of 450, 585 and 700 K. Antiferromagnetic correlations are observed to be present at all the temperatures studied. The spectral width of the magnetic scattering has been observed to increase with temperature, while the spatial range of the magnetic correlations is seen to decrease as the temperature is raised. The wave-vector-dependent susceptibility is found to follow a Curie-Weiss law near the (1 0 0) position, in agreement with theoretical predictions.

2006-11-15

25

Correlation between Magnetic Field Quality and mechanical components of the Large Hadron Collider Main Dipoles  

CERN Document Server

The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.

2006-01-01

26

Rotating magnetic tensor gradiometry and a superconducting implementation  

International Nuclear Information System (INIS)

This work describes the theoretical basis for a new concept rotating magnetic tensor gradiometer. The rotating gradiometer consists of an approximately axial or transverse gradiometer which is made to rotate about a perpendicular axis so that the direction of sensitivity is continually changing. It is demonstrated for the first time that the rotation separates gradient components of progressively higher-order in the frequency domain and enables absolute-value measurements of all components of the first-order magnetic gradient tensor, even if the magnetic sensors comprising the gradiometer are intrinsically incapable of absolute-value detection. In addition, the rotating gradiometer concept has a number of other advantages: the gradiometer imbalance is no longer directly determined by the engineering precision, the DC and low-frequency performance of the instrument is not limited by the performance of ...

2009-07-01

27

Multiple-element eddy current probes for enhanced inspection  

Energy Technology Data Exchange (ETDEWEB)

Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe ...

1993-07-01

28

Adaptive and mobile ground sensor array.  

Energy Technology Data Exchange (ETDEWEB)

The goal of this LDRD was to demonstrate the use of robotic vehicles for deploying and autonomously reconfiguring seismic and acoustic sensor arrays with high (centimeter) accuracy to obtain enhancement of our capability to locate and characterize remote targets. The capability to accurately place sensors and then retrieve and reconfigure them allows sensors to be placed in phased arrays in an initial monitoring configuration and then to be reconfigured in an array tuned to the specific frequencies and directions of the selected target. This report reviews the findings and accomplishments achieved during this three-year project. This project successfully demonstrated autonomous deployment and retrieval of a payload package with an accuracy of a few centimeters using differential global positioning system (GPS) signals. It developed an autonomous, multisensor, temporally aligned, radio-frequency ...

2003-12-01

29

High-mode-number ballooning modes in a heliotron/torsatron system: 1, Local magnetic shear  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal force balance in the ...

1996-05-01

30

Position-sensitive spectroscopy of 252Cf fission fragments  

International Nuclear Information System (INIS)

The fission fragments from spontaneous fission of 252Cf have been measured with the spectrometric and position-sensitive semiconductor pixel detector Medipix2. Fragments are identified by pattern recognition of clusters generated in the Medipix2 pixel matrix sensor upon heavy particle hit. From analysis of cluster area, the distribution of kinetic energy of fission fragments is obtained. Together with a novel USB readout interface, the Medipix2/USB system operates as active nuclear emulsion in single-quantum and on-line tracking mode.

2007-05-11

31

Improved quadrant anode image sensor with microchannel plates  

Energy Technology Data Exchange (ETDEWEB)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-15

32

An improved quadrant anode image sensor with microchannel plates  

International Nuclear Information System (INIS)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).

1987-11-01

33

An improved quadrant anode image sensor with microchannel plates  

Science.gov (United States)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-01

34

Dimensional metrology and positioning operations: basics for a spatial layout analysis of measurement systems  

CERN Document Server

Dimensional metrology and positioning operations are used in many fields of particle accelerator projects. This lecture gives the basic tools to designers in the field of measure by analysing the spatial layout of measurement systems since it is central to dimensional metrology as well as positioning operations. In a second part, a case study dedicated to a synchrotron storage ring is proposed from the detection of the magnetic centre of quadrupoles to the orbit definition of the ring.

2010-01-01

35

Quantum locking of mirrors in interferometric measurements  

International Nuclear Information System (INIS)

We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.

2004-03-07

36

Itinerant magnetism of Gd_xLa_1_-_xMSi (M=Fe, Co) compounds  

International Nuclear Information System (INIS)

The magnetic properties of polycrystalline and single crystalline rare earth transition metal silicides Gd_xLa_1_-_xMSi (M =Fe, Co) were investigated. Magnetic measurements have been made in static magnetic fields up to 13 kOe and in pulsed magnetic fields up to 250 kOe in the temperature range from 4.2 to 350 K. The magnetic susceptibility in the paramagnetic state of all the investigated compounds obeys the Curie-Weiss law except for LaFeSi and LaCoSi. Increase of the La content in Gd_xLa_1_-_xFeSi compounds leads to a decrease of the Curie and Neel temperatures, which can be explained by a decrease of positive exchange interactions. (orig.).

1995-09-01

37

Automatic beam position control at Los Alamos Spallation Radiation Effects Facility (LASREF)  

Energy Technology Data Exchange (ETDEWEB)

Historically the Los Alamos Spallation Radiation Effects Facility (LASREF) has used manual methods to control the position of the 800 kW, 800 MeV proton beam on targets. New experiments, however, require more stringent position control more frequently than can be done manually for long periods of time. Data from an existing harp is used to automatically adjust steering magnets to maintain beam position to required tolerances.

1997-08-01

38

Powertrain and apparatus using a continuously variable ratio transmission to improve fuel economy  

Energy Technology Data Exchange (ETDEWEB)

An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are ...

1981-07-28

39

Development of the SSC (Superconducting Super Collider) trim coil beam tube assembly  

Energy Technology Data Exchange (ETDEWEB)

The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.

1987-01-01

40

Crossover of the magnetic levels and adiabatic magnetization of the mesoscopic cluster V15  

British Library Electronic Table of Contents (United Kingdom)

The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...

2006-01-01

41

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

42

Nondestructive Detection Techniques of Garter Springs from CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.

2004-04-15

43

Tunneling magnetoresistance from a symmetry filtering effect  

International Nuclear Information System (INIS)

This paper provides a brief overview of the young, but rapidly growing field of spintronics. Its primary objective is to explain how as electrons tunnel through simple insulators such as MgO, wavefunctions of certain symmetries are preferentially transmitted. This symmetry filtering property can be converted into a spin-filtering property if the insulator is joined epitaxially to a ferromagnetic electrode with the same two-dimensional symmetry parallel to the interface. A second requirement of the ferromagnetic electrodes is that a wavefunction with the preferred symmetry exists in one of the two spin channels but not in the other. These requirements are satisfied for electrons traveling perpendicular to the interface for Fe-MgO-Fe tunnel barriers. This leads to a large change in the resistance when the magnetic moment of one of the electrodes is rotated relative to those of the other electrode. This large tunneling magnetoresistance effect is being used as the ...

2008-04-01

44

Giant magnetoresistance sensing technologies for detecting small defects in metallic structures  

Science.gov (United States)

Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.

2008-01-01

45

Giant magnetoimpedance effect and voltage response in meander shape Co-based ribbon  

British Library Electronic Table of Contents (United Kingdom)

Field-annealed Co-based amorphous ribbon (Metglas? 2705M) with a meander structure is fabricated by MEMS technology and the giant magnetoimpedance (GMI) effects are studied at different magnetic fields and frequencies. The maximum longitudinal GMI ratio of the ribbon is 193.7% and the magnetic field sensitivity is 17.4%/Oe. The maximum GMI ratio of the meander ribbon is much larger than the single strip ribbon mainly due to the larger change ratio of inductance L. The sensitivity of an output U reach up to 10 V/A and U thermal fluctuation is less than 15 mV in the temperature range of ?20 to 40?C. This meander shape ribbon can be considered as a good candidate for the GMI-based sensor fabrication.

2010-01-01

46

Laser ray-tracing method for optical testing.  

Science.gov (United States)

We have developed a novel laser ray-tracing method to measure aberrations in optical systems. It consists of delivering narrow laser pencils (by a laser scanner), recording the spots that are formed on the image plane (with a CCD camera), and computing the position of each centroid. This approach could be considered an experimental (approximate) implementation of standard numerical ray tracing. Several tests and experiments, including a direct comparison with a Hartmann-Shack wave-front sensor, provided highly satisfactory results that confirmed the validity of the method and revealed potential advantages. PMID:18073906

1999-07-15

47

Quadrant anode image sensor  

Science.gov (United States)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)

1976-11-01

48

Quadrant anode image sensor  

International Nuclear Information System (INIS)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.

9472-01-01

49

Low-temperature properties of ternary magnetic rare-earth transition-metal germanides with the Sc sub 5 Co sub 4 Ge sub 10 -type structure  

Energy Technology Data Exchange (ETDEWEB)

DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque ...

1988-01-01

50

Low temperature properties of ternary magnetic rare earth transition metal germanides with the Sc/sub 5/Co/sub 4/Ge/sub 10/-type structure  

Energy Technology Data Exchange (ETDEWEB)

DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the ...

1988-07-01

51

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

52

Advances in sensor technology  

Energy Technology Data Exchange (ETDEWEB)

During thirty years the techniques used for sensing the environment have changed dramatically. This paper describes the latest generation of sensors available. This new generation of sensors includes those two most critical gas sensors for methane and carbon monoxide and new sensors for airflow and air temperature. When these sensors are combined with the new sensors for machine condition monitoring it forms the heart of the Sentex system. 2 figs.

1989-06-01

53

Tunnel Sensors Equipment on Environmental Expert  

Wastenet

... Tunnel Sensors Equipment on Environmental Expert Find and compare a variety of tunnel sensors equipment on the world's largest environmental industry portal. View ...

54

The magnetic resonance and its agro-industry applications; a review  

International Nuclear Information System (INIS)

The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage and conservation of fruits in controlled and ...

55

Equivalent magnetic noise in magnetoelectric Metglas/Pb(Mg1/3Nb2/3)O3-PbTiO3 laminate composites  

British Library Electronic Table of Contents (United Kingdom)

Abstract We have experimentally and theoretically investigated the equivalent magnetic noise in a magnetoelectric Metglas/ 0.7Pb(Mg1/3Nb2/3)O3-0.3PbTiO3 laminate sensor unit by considering the constituent noise sources of dielectric loss (NDE) and DC leakage resistance (NR). In the low frequency range (f = 1 Hz), theory predicts that NR dominates the noise charge (1.6 times larger than NDE), with a 1 Hz noise of 9.1\\;{\\rm pt}/\\sqrt {\\rm Hz}. The experimental equivalent magnetic noise was 10.8\\;{\\rm pt}/\\sqrt {\\rm Hz}. This observed value is slightly higher than the predicted one, which might be due to an oversimplification of the theoretical model in terms of electrical charge amplifier and external vibration noise sources. ( 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

2011-01-01

56

A DRAMATICALLY REDUCED SIZE IN THE GANTRY DESIGN FOR THE PROTON-CARBON THERAPY.  

Energy Technology Data Exchange (ETDEWEB)

Gantries in the proton/carbon cancer therapy machines represent the major cost and are of the largest size. This report explains a new way to the gantry design. The size and cost of the gantries are reduced and their use is simplified by using the fixed magnetic field. The ''new'' gantry is made of a very large momentum acceptance non-scaling Fixed Field Alternating Gradient (FFAG) quarter and half arc beam lines. The gantry is made of combined function magnets with a very strong focusing and small dispersion function. Additional magnets with a fast response are required to allow adjustments of the beam position for different energies at the beginning of the gantry. Additional strong focusing magnets following the gantry have also to be adjustable to provide required spot size and radial scanning above the patients. The fixed field combined ...

2006-06-23

57

Use of Computer Vision and Force Sensors for Tight ...  

Science.gov (United States)

... Accession Number : ADD811953. Title : Use of Computer Vision and Force Sensors for Tight Tolerance Assembly. Descriptive ...

1993-05-01

58

REVIEW OF US METEOROLOGICAL ROCKET NETWORK ...  

Science.gov (United States)

... more and better sensors to be ... all the continuously incoming data, which ... RANGE RECEIVER THERMAL CONDUCTIVITY ,# PRESSURE SENSOR ...

2011-05-14

59

Iao: The New Adaptive Optics Visible Imaging and ...  

Science.gov (United States)

... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...

2008-09-01

60

Biology-Inspired Distributed Consensus in Massively-Deployed Sensor Networks  

Science.gov (United States)

Promises of ubiquitous control of the physical environment by large-scale wireless sensor networks

2005-01-01

61

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a ...

2002-01-01

62

Direct energy recovery with ac electric power output  

Energy Technology Data Exchange (ETDEWEB)

A concept of direct energy recovery system applying an alternating or rotating magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. Nearly same amounts of residual positive and negative hydrogen-isotope ion beams with beam energy of {approx}1 MeV are produced in an NNB using a gas neutralizing cell. Consequently, a recovered energy is obtained directly in the form of ac electric power, if these positive- and negative-ion beams are alternated or rotated and introduced to two or more recovery electrodes in turn by an alternating or rotating magnetic field. This concept will greatly reduce a technological difficulty in regeneration of a recovered electric energy with such a very high voltage. (author).

1994-12-31

63

Mechanical variations of diffused plasma parameters in a double plasma device  

International Nuclear Information System (INIS)

Experimentally it is shown that a movable grounded metallic plate placed inside a multi-dipole magnetic cage can vary the diffused plasma parameters such as density, plasma potential and electron temperature. Plasma is solely produced in the source section of a double plasma device by a dc hot filament discharge and a low-density plasma is produced in the target section by local ionization of neutral gas by the high energetic electrons coming from the source section. A grounded movable stainless steel plate is inserted in the target section of the device. The floating potential of the plate also changes depending on the position of the plate inside the magnetic cage.

2007-06-21

64

Implantation of single-impurity Fe and its magnetic coupling in Er studied by TDPAD  

Energy Technology Data Exchange (ETDEWEB)

Single Fe impurities were implanted in an Er single crystal and found to occupy both substitutional and interstitial sites, below a temperature of 200 K. The local susceptibility of Fe on both sites follows a Curie-Weiss law and exhibits a positive local Curie constant, indicating an antiferromagnetic coupling between the Fe and the surrounding Er moments. The corresponding nuclear spin relaxation rates follow a Korringa law as a function of temperature, confirming the dominance of local magnetism and the formation of local moments on each of the sites occupied by Fe.

2004-05-01

65

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, the authors are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. They are actively developing improved DC iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. They are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. They are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1988-03-01

66

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, we are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. We are actively developing improved dc iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. We are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. We are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1987-01-01

67

A simple route to a tunable electromagnetic gateway  

CERN Document Server

Transformation optics is used to design a gateway that can block electromagnetic waves but allows the passage of other entities. Our conceptual device has the advantage that it can be realized with simple materials and structural parameters and can have a reasonably wide bandwidth. In particular, we show that our system can be implemented by using a magnetic photonic crystal structure that employs a square ray of ferrite rods, and as the field response of ferrites can be tuned by external magnetic fields, we end up with an electromagnetic gateway that can be open or shut using external fields. The functionality is also robust against the positional disorder of the rods that made up the photonic crystal.

2009-01-01

68

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

69

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

70

Creation of nitrogen-vacancy centres in diamond with high resolution  

International Nuclear Information System (INIS)

Nowadays, diamond and the nitrogen-vacancy (NV) colour centres constitute the best solid-state system in view of quantum-computing applications. It has also been shown recently that single NV centres could be used as nanoscale magnetic sensors. Such applications require the creation of single NV centres with very high resolution and with a high efficiency. The nano-implanter at the university of Bochum provides low energy nitrogen ions which can be implanted through a hole pierced in the tip of an atomic force microscope. Ultrapure diamond samples have been implanted with spot sizes of 50nm and less. Stimulated Emission Depletion (STED) microscopy has been used to characterise and resolve the implanted spots.

2010-03-21

71

Ceramic Materials and Devices  

Science.gov (United States)

Course website from Cambridge on ceramic materials. This site contains eight lectures in PDF format (Adobe Reader required), two question sheets, five practicals (including answers), digital movies and further useful links. "There is a strong relationship between the structure of a material and its physical properties. The properties of a material whether mechanical, electrical, optical or magnetic, determine how it can be used in practical applications. In this course, the focus is on the structure / property relationship for ionic materials with electrical properties utilised in various transducer devices. The materials considered include perovskites, which have special polarisation properties exploited in ferroelectric, pyroelectric and piezoelectric devices. Other oxides, such as zirconia, have structures permitting rapid diffusion of ions, making them suitable for use in sensors, fuel cells and batteries. The scientific principles ...

2007-02-01

72

Advances in amorphous and nanocrystalline magnetic materials  

International Nuclear Information System (INIS)

Recent advances made in the area of amorphous and nanocrystalline alloys exhibiting high saturation inductions are reviewed. A new chemical composition was identified that achieves a saturation induction of 1.64 T in an iron-based amorphous alloy. This alloy, when used in electrical transformers, shows a much improved performance over the existing amorphous alloy. Nanocrystalline FeCoCuNbSiB alloys are found to have saturation induction levels reaching 1.7 T. These materials are suited for use in sensors and inductors carrying large currents. Some of these nanocrystalline alloys show a BH squareness ratio exceeding 90%, which can be utilized in pulse power devices. Recent developments in the applications of these materials are also pointed out.

2006-09-01

73

Crystal electric field excitations in the cerium compound CeRh{sub 3}B{sub 2} studied by inelastic neutron scattering  

Energy Technology Data Exchange (ETDEWEB)

We have performed inelastic neutron scattering (INS) experiments on CeRh{sub 3}B{sub 2} at various temperatures to obtain direct information on the crystal electric field (CEF) in this compound, which exhibits some very peculiar magnetic properties for a Ce system: it is ferromagnetic with an unusually high Curie temperature (115 K), which contrasts with a strongly reduced and anisotropic magnetization (0.4 {mu}{sub B}/fu within the c-plane of the hexagonal structure). Measurements with high incident energies show only one well defined magnetic excitation around 150 meV, its exact position varying with the temperature. These results, combined with our previous data of magnetization and magnetic form factor, have permitted us to determine the CEF energy level scheme taking into account the two J multiplets of the Ce{sup 3+} ion. Information on the ground state ...

2007-12-19

74

Crystal electric field excitations in the cerium compound CeRh_3B_2 studied by inelastic neutron scattering  

International Nuclear Information System (INIS)

We have performed inelastic neutron scattering (INS) experiments on CeRh_3B_2 at various temperatures to obtain direct information on the crystal electric field (CEF) in this compound, which exhibits some very peculiar magnetic properties for a Ce system: it is ferromagnetic with an unusually high Curie temperature (115 K), which contrasts with a strongly reduced and anisotropic magnetization (0.4 #mu#_B/fu within the c-plane of the hexagonal structure). Measurements with high incident energies show only one well defined magnetic excitation around 150 meV, its exact position varying with the temperature. These results, combined with our previous data of magnetization and magnetic form factor, have permitted us to determine the CEF energy level scheme taking into account the two J multiplets of the Ce"3"+ ion. Information on the ground state (quasielastic ...

2007-12-19

75

Three-dimensional, three-component wall-PIV  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set simulating a rotating sphere. (orig.)

2010-06-15

76

Robotic drilling system for titanium structures  

British Library Electronic Table of Contents (United Kingdom)

Manual drilling in titanium structures is a tedious and labor-intensive work. To reduce man-hour requirements while concurrently improving hole quality, we developed a robotic drilling system for this application. The lean system contains the product holding fixture, the industrial robot, the end effector, the control and sensor system, and the offline programming. The system functions include locating workpiece with a calibration stick or the vision system, weld mark inspection, one-sided clamping, drilling and reaming hole in material stack combinations of titanium and aluminum, and real-time thrust force feedback. The positional accuracy and the repeatability of the system have successfully been placed within the specification?s 0.3?mm tolerance and 0.2?mm tolerance, respectively. The d...

2011-01-01

77

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

78

Destabilization of the hot-electron precessional mode in tandem mirrors and bumpy tori  

International Nuclear Information System (INIS)

The high-frequency precessional mode of a hot-electron-stabilized magnetic configuration has previously been shown to be stable in a window of core-plasma mass. Under conditions of frequency matching, the resulting stable negative-energy precessional wave can be destabilized by coupling to positive-energy shear-Alfven waves. Coupling is avoided when the hot-electron precession frequency exceeds the core-plasma ion gyrofrequency.

79

The magnetic spectrometer PAMELA for the study of cosmic antimatter in space  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.

1995-09-01

80

Effects of transverse magnetic field, Prandtl number and Reynolds number on non-Darcy mixed convective flow of an incompressible viscous fluid past a porous vertical flat plate in a saturated porous medium  

Energy Technology Data Exchange (ETDEWEB)

The effect of transverse magnetic field parameter (Hartmann number, Ha) Reynolds number (Re) and Prandtl number (Pr) on the mixed convection flow past a semi-infinite vertical porous plate in a non-Darcian porous medium with variable viscosity and porosity, viscous dissipation and fluid-solid thermal conductivity ratio in the presence of plate transpiration (lateral mass flux) is investigated theoretically and numerically using Keller`s implicit finite difference scheme. It is shown that the Harmann number acts as a retarding force and increases the momentum boundary layer thickness, analogous to the flow against a positive pressure gradient, simultaneously decreasing local skin friction (shear stress). The heat transfer rate is however enhanced by the magnetic field (for positive values of the Eckert number) since the fluid is heated and temperature gradients become reduced between the fluid and the ...

1997-01-01

81

HORIZON SENSING  

Energy Technology Data Exchange (ETDEWEB)

With the aid of a DOE grant (No. DE-FC26-01NT41050), Stolar Research Corporation (Stolar) developed the Horizon Sensor (HS) to distinguish between the different layers of a coal seam. Mounted on mining machine cutter drums, HS units can detect or sense the horizon between the coal seam and the roof and floor rock, providing the opportunity to accurately mine the section of the seam most desired. HS also enables accurate cutting of minimum height if that is the operator's objective. Often when cutting is done out-of-seam, the head-positioning function facilitates a fixed mining height to minimize dilution. With this technology, miners can still be at a remote location, yet cut only the clean coal, resulting in a much more efficient overall process. The objectives of this project were to demonstrate the feasibility of horizon sensing on mining machines and demonstrate that Horizon Sensing can allow coal to be cut cleaner and more ...

2003-03-18

82

Integrated Analysis of Environment-driven Operational Effects in Sensor Networks  

Energy Technology Data Exchange (ETDEWEB)

There is a rapidly growing need to evaluate sensor network functionality and performance in the context of the larger environment of infrastructure and applications in which the sensor network is organically embedded. This need, which is motivated by complex applications related to national security operations, leads to a paradigm fundamentally different from that of traditional data networks. In the sensor networks of interest to us, the network dynamics depend strongly on sensor activity, which in turn is triggered by events in the environment. Because the behavior of sensor networks is sensitive to these driving phenomena, the integrity of the sensed observations, measurements and resource usage by the network can widely vary. It is therefore imperative to accurately capture the environmental phenomena, and drive the simulation of the sensor network operation ...

2007-07-01

83

TIME EVOLUTION OF CORONAL MAGNETIC HELICITY IN THE FLARING ACTIVE REGION NOAA 10930  

International Nuclear Information System (INIS)

To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through the surface. (2) The ...

2010-09-10

84

Disturbance Rejection Control of an Electromagnetic Bearing Spindle  

Energy Technology Data Exchange (ETDEWEB)

The force exerted on the rotor by an active magnetic bearing (AMB) is determined by the current flow in the magnet coils. This force can be controlled very precisely, making magnetic bearings a potential benefit for grinding, where cutting forces act as external disturbances on the shaft, resulting in degraded part finish. It is possible to achieve precise shaft positioning, reduce vibration of the shaft caused by external disturbances, and even damp out resonant modes. Adaptive control is an appealing approach for these systems because the controller can tune itself to account for an unknown periodic disturbance, such as cutting or grinding forces, injected into the system. In this paper the authors show how one adaptive control algorithm can be applied to an AMB system with a periodic disturbance applied to the rotor. An adaptive algorithm was developed and implemented in both simulation and hardware, ...

2000-08-31

86

Ranger 8 - NASA - NSSDC - Spacecraft - Details  

Science.gov (United States)

5 days ago... Sun sensors, 2 secondary Sun sensors, and an Earth sensor. ... This continued intermittently until the rocket burn, at which time ... with incoming asymptotic direction at an angle of -13.6 degrees from the lunar equator. ...

87

A micromachined high pressure stable mass flow sensor for common-rail injection systems; Ein mikromechanisch gefertigter hochdruckstabiler Massenflusssensor fuer Common-Rail(CR)-Einspritzsysteme  

Energy Technology Data Exchange (ETDEWEB)

We report for the first time about a micromachined mass flow sensor directly integrated between the double guidance and the needle seat into the body of a Common Rail (CR) injection nozzle. The thermal measurement principle was chosen because gaseous as well as liquid mass flows can be determined fast and precisely. Additionally, with glass-ceramic materials fabricated in a low cost batch process, a high temperature and especially pressure stable substrate can be used. The flow sensitive thin film is realized by an e-beam evaporated 110 nm thick molybdenum (Mo) layer. The latter is electrically characterized by the resistivity of {rho} = 8.2 x 10{sup -7} {omega} m ({+-}2%) at room temperature as well as by the first {alpha}=4.5 x 10{sup -4} K{sup -1} ({+-}5%) and second {beta}=3.0 x 10{sup -6} K{sup -2} ({+-}12%) temperature coefficients of resistance up to 300 C. The static temperature field at and around the thin film sensor on the ...

2001-05-01

88

The metrology of the LHC project: what news?  

Energy Technology Data Exchange (ETDEWEB)

The Large Hadron Collider (LHC), under construction at CERN, uses superconducting magnets operating at a temperature of 1.9 K to guide the circulating particles. A specific feature of the main magnets (dipoles and quadrupoles) is the two-in-one design with two magnetic channels in one common retaining structure. Indeed, the accelerator is made of two rings, mechanically linked, that have to be simultaneously aligned during the installation in the already existing LEP tunnel. The assembly tolerances of the LHC main magnets have been reconsidered to take into account the tight constraints on geometry. The dipoles are bent to follow closely the curvature of the circulating particles and to make a larger mechanical aperture available for the circulating particles. In order to minimise the geometrical errors the dipole assembly procedure is assisted by high precision survey measurements based on laser ...

1999-07-01

89

USGS Scientists Installing Temperature Sensor  

USGS Gallery

USGS scientists Laura Clor and Tim Moloney installing a temperature sensor under a public boardwalk in Norris Geyser Basin, Yellowstone National Park....

2010-09-29

90

Sensor for monitoring the angle of rotation of a drag  

Energy Technology Data Exchange (ETDEWEB)

The operating principle is examined for an optical sensor for the angle of rotation of the drag ODUP-1 developed and manufactured by the VNII-1. Basic technical data are presented for the experimental model.

1980-01-01

91

Optical sensor for temperature measurement using bimetallic concept  

British Library Electronic Table of Contents (United Kingdom)

In this paper, we report an optical fiber sensor for measuring temperature based on bimetallic concept. The sensor is designed by following the basic principle of Fabry-Perot interferometer and theoretical detail of the sensor has been outlined here with a numerical study. An important feature of the proposed sensor is that the fabrication will be done on a commercial multimode optical fiber. The Micro-Electro-Mechanical Systems (MEMS) based fabrication process could be performed directly on a multimode optical fiber end face which will eliminate the need for adhesive in packaging. The sensor could be fabricated as sensor arrays for micro level applications. The potential application of the proposed optical sensor includes biomedical applications, nano research, microfluidics, and other ME...

2011-01-01

92

Improving The Science Returns on Coastal Sensor Webs Using  

Science.gov (United States)

UUV coordination. Event Estimation. Threat assessment. (environment, intel). Adaptive Predictive. Controller. Mobile robot tasking. Static sensor operation ...

93

Using Multimedia Learning Modules in a Hybrid-Online Course in Electricity and Magnetism  

Science.gov (United States)

We have been piloting web-based multimedia learning modules (MLMs), developed by the Physics Education Research Group at the University of Illinois at Urbana Champaign (UIUC), as a "prelecture assignment" in several introductory physics courses at California State Polytechnic University at Pomona. In this study, we report the results from a controlled study utilizing modules on electricity and magnetism as a part of a blended hybrid-online course. We asked students in the experimental section to view the MLMs prior to attending the face-to-face class, and to make sure this would not result in additional instructional time, we reduced the weekly class time by one-third. We found that despite reduced class time, student-learning outcomes were not hindered; in fact, the implementation of the UIUC MLMs resulted in a positive effect on student performance on conceptual tests and classroom discussion questions. (Contains 4 figures and 1 table.)

2010-12-01

94

Polarized neutron diffraction study of CePd{sub 3}  

Energy Technology Data Exchange (ETDEWEB)

We have performed polarized neutron diffraction measurements on the intermediate valence compound CePd{sub 3} using the D3 spectrometer at the ILL. The results show that at low temperatures, 1.7 K, as well as at 100 K, the field-induced magnetic amplitudes measured in a field of 4.6 T could be interpreted in terms of two contributions: a 4f-type contribution with a Ce{sup 3+} form factor, and an extra delocalized contribution (relatively narrow in q-extent). In particular, we find that the values of the 4f moment deduced from the extrapolation of the neutron data to Q=0 are systematically lower than the values deduced from bulk magnetization measurements performed on the same sample. This difference can be ascribed to a possible positive polarization of the conduction band which is similar at both temperatures.

2004-07-15

95

Polarised neutron reflectometry study of Co/CoO exchange-biased multilayers  

Energy Technology Data Exchange (ETDEWEB)

We have investigated via SQUID magnetometry and polarised neutron reflectivity the exchange-bias effect in CoO/Co sputtered multilayers. In particular, we studied the magnetisation reversal and the time relaxation of the exchange-bias field close to the coercive field H{sub c1}. Neutron intensities of all four cross sections (I++, I+-, I-+, I-) were recorded at the position of the first multilayer Bragg peak while scanning the magnetic field. From such scans we infer that the magnetisation reversal for the ascending as well as for the descending branch of the magnetic hysteresis occurs not by in-plane rotation but through domain-wall movements. The exchange-bias field, H{sub EB}, is strongly affected by thermal fluctuations. H{sub EB} decreases, following an exponential decay function with a half-life time of about 580 s at T=240 K. (orig.)

2002-07-01

96

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

97

Fundamental limits on beam stability at the advanced photon source  

International Nuclear Information System (INIS)

Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.

1998-12-10

98

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

99

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

100

HINS Linac front end focusing system R&D  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes current status of an R&D program to develop a focusing system for the front end of a superconducting RF linac. Superconducting solenoids will be used as focusing lenses in the low energy accelerating sections of the front end. The development of focusing lenses for the first accelerating section is in the production stage, and lens certification activities are in preparation at FNAL. The report contains information about the focusing lens design and performance, including solenoid, dipole corrector, and power leads, and about cryogenic system design and performance. It also describes the lens magnetic axis position measurement technique and discusses scope of an acceptance/certification process.

2008-08-01

101

Electron collisional detachment processes for a 250 keV D/sup -/ ion beam in a partially ionized hydrogen target  

Energy Technology Data Exchange (ETDEWEB)

Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.

1980-09-01

102

Structure and magnetic properties of the UNi_1_0_-_xFe_xSi_2 system and "2"9Si nuclear magnetic resonance in UNi_1_0Si_2  

International Nuclear Information System (INIS)

Structure and magnetic properties of UNi_1_0_-_xFe_xSi_2 intermetallics and "2"9Si nuclear magnetic resonance (NMR) in UNi_1_0Si_2 are investigated in a wide temperature range. Solid solutions in the exactly single-phase tetragonal form, ThMn_1_2 type, exist for x<2. The Ni and Fe atoms occupy the 8(f), 8(i) and 8(j) positions statistically, whereas the U atoms occupy the 2(a) and the Si atoms the 8(j) sites. The lattice parameters roughly follow Vegard's law. The magnetic susceptibility does not exhibit Curie-Weiss behaviour and, at about 630 K, an anomaly in the temperature dependence is observed. At low temperature, other anomalies are observed at 32 K and 45 K, for x=0.5 and 1.0 respectively. These low temperature anomalies are probably connected with magnetic ordering of a ferromagnetic character, whereas that at 630 K might result from the superparamagnetic state of Ni. Two ...

1993-09-01

103

Magnetic properties and low temperature X-ray studies of the weak ferromagnetic monoclinic and trigonal chromium tellurides Cr_5Te_8  

International Nuclear Information System (INIS)

Monoclinic and trigonal Cr_5Te_8 show a transition into the ferromagnetic state with a Curie temperature T_c, which sensitively depends on the actual composition. Monoclinic samples exhibit a lower T_c despite their higher Cr content. This observation is explained on the basis of less effective ferromagnetic superexchange in the monoclinic compounds and the larger number of Cr atoms being antiferromagnetically coupled. Magnetization experiments performed at 5 K demonstrate that the compounds saturate already at rather low magnetic fields. In addition, small values are estimated for the coercitive field H_c as well as for the remanence magnetization both being typical for weak ferromagnetic materials. The values for the saturation magnetization amount to about 72% and 65% for monoclinic and trigonal Cr_5Te_8, respectively. These low values can partially be explained on the basis of antiferromagnetically ...

2004-03-01

104

Electromagnetic structure of decuplet baryons towards the chiral regime  

Science.gov (United States)

The electromagnetic properties of the baryon decuplet are calculated in quenched QCD on a 20{sup 3}x40 lattice with a lattice spacing of 0.128 fm using the fat-link irrelevant clover fermion action with quark masses providing a pion mass as low as 300 MeV. Magnetic moments and charge radii are extracted from the electric and magnetic form factors for each individual quark sector. From these, the corresponding baryon properties are constructed. We present results for the higher-order moments of the spin-3/2 baryons, including the electric-quadrupole moment E2 and the magnetic-octupole moment M3. The world's first determination of a nonzero M3 form factor for the {delta} baryon is presented. With these results we provide a conclusive analysis which shows that decuplet baryons are deformed. We compare the decuplet-baryon results from a similar lattice calculation of the octet baryons. We establish that the environment ...

2009-09-01

109

Application of wireless sensor system to maintenance of steel construction  

International Nuclear Information System (INIS)

... Engineering, Kitakyushu, Fukuoka (Japan) Hattanda, Takumi NTT Advanced

2009-09-01

110

Turbulence in the positive column of a glow discharge  

CERN Document Server

Turbulence in the positive column of a glow discharge

1969-01-01

111

FY 1999 project on the development of new industry support type international standards. Standardization of evaluation testing method of thermal properties of polymer materials; 1999 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Kobunshi zairyo no netsutokusei hyoka shiken hoho no hyojunka  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of proposing it to ISO, the R and D were conducted of a new evaluation method of thermal properties of polymer materials. The FY 1999 results were summarized. In this fiscal year, the development of the ac Joule heating equipment was proceeded with based on the study at the technical committee, and the measuring device was installed. In the comparative measurement with conventional methods, study was proceeded with of the laser flash method, AC calorimetry method and specific heat measurement. In the technical survey, the developmental state of the ac method, especially, was examined as a testing method of thermal properties of polymer materials. It is in the stage of the basic research by keyword selection, and the search for literature is to be made in full scale. As to the needs in the industrial circle, as a result of the questionnaire survey made, it was found out that there were a wide variety of the needs for general-purpose/functional film materials, forming ...

2000-03-01

112

Negative ion source electrode  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a negative ion source electrode which can be preferably used in a neutral particle injection device using negative ions for a thermonuclear reactor. Negative ion beams are deflected to the direction opposite to the deflecting direction by magnetic fields by using an electron suppression electrode having electrode holes with the position previously displaced before negative ion beams are accelerated to have a high energy by an accelerator thereby correcting the orbit of the negative ion beams easily. In addition, since the deflection correction electrode having the electrode holes is disposed, a proper voltage is applied to the deflection correction electrode to correct the orbit of the negative ion beams conveniently. Since the deflection correction electrode has a simple structure of a thin flat plate having electrode holes, the orbit of negative ion beams can be corrected efficiently by an extremely simple ...

1997-01-17

114

Sensors to detect CO based in SnO. Sensores para detectar CO basados en SnO  

Energy Technology Data Exchange (ETDEWEB)

The development of solid state chemical sensors, and more specifically of gas sensors, is carried out with great strength in the present time since the environmental pollution and the security in work and domestic ambient are problems of great interest and social impact. The main fields of application, are: automobile, domestic sensors, control of industrial process, bio medicine, environment. These chemical sensors are experimenting a great advance because of the advantages they offer, as low cost, simple operation, possibility of measure continuous and ''In situ'' and small size, in contrast with analytical techniques that need complex instrumentation and large size equipments. In the present work, a sensor for CO detecting concentrations as low as 50 p.p.m., is studied showing great interest since this gas is highly toxic even to such a low ...

1993-01-01

115

Study of modal parameters and vibration signatures of notched concrete prisms  

International Nuclear Information System (INIS)

In the present study, vibration tests have been carried out on notched concrete prisms. The tests have been conducted to study modal parameters and vibration signatures in order to enhance the knowledge of monitoring concrete structures. Notch (artificially introduced crack) of constant widths and varying depths has been introduced in the concrete prisms at different locations. The specimens have been subjected to impact excitations by dropping a specific weight from a fixed height and at a particular location. The natural frequencies of notched and intact prisms have been experimentally measured. The frequency response functions (FRF) as obtained from multichannel pulse analyzer have been synthesized to evaluate the fundamental mode shape of vibration of the prisms by a curve fitting method. These curves have been further post-processed to obtain the modal curvature values. Pattern Recognition Scheme is applied to synthesize vibration signatures for the evaluation of the curvature ...

2006-03-01

116

Electron flow in the SABRE linear induction adder in positive polarity  

International Nuclear Information System (INIS)

In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated Transmission Line (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first cavities was greater than in the simulations. The authors have ...

1993-05-17

117

A search for electron cyclotron maser emission from compact binaries  

CERN Document Server

Unipolar induction (UI) is a fundamental physical process, which occurs when a conducting body transverses a magnetic field. It has been suggested that UI is operating in RX J0806+15 and RX J1914+24, which are believed to be ultra-compact binaries with orbital periods of 5.4 min and 9.6 min respectively. The UI model predicts that those two sources may be electron cyclotron maser sources at radio wavelengths. Other systems in which UI has been predicted to occur are short period extra-solar terrestrial planets with conducting cores. If UI is present, circularly polarised radio emission is predicted to be emitted. We have searched for this predicted radio emission from short period binaries using the VLA and ATCA. In one epoch we find evidence for a radio source, coincident in position with the optical position of RX J0806+15. Although we cannot completely exclude that this is a chance alignment between the ...

2007-01-01

118

The year 2000 embedded systems problem to maintain the safety of nuclear installations  

International Nuclear Information System (INIS)

The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors or, by operating a valve, may control the flow of cooling system to reactor core. Embedded systems in our organization are also ...

1999-02-01

119

The Development of a Neutral Particle Detector for Observations of the Thermosphere  

Science.gov (United States)

One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight instrument uses ...

2006-12-01

120

Growth of Cr-Nitrides on commercial Ni-Cr and Fe-Cr base alloys to protect PEMFC bipolar plates  

Energy Technology Data Exchange (ETDEWEB)

Nitridation of Cr-bearing alloys can yield low interfacial contact resistance (ICR), electrically conductive and corrosion-resistant CrN or Cr{sub 2}N base surfaces of interest for a range of electrochemical devices, including fuel cells, batteries, and sensors. This paper presents results of exploratory studies of the nitridation of commercially available, high Cr (30-35 wt%) Ni-Cr alloys and a ferritic high Cr (29 wt%) stainless steel for proton exchange membrane fuel cell (PEMFC) bipolar plates. A high degree of corrosion resistance in sulfuric acid solutions designed to simulate bipolar plate conditions and low ICR values were achieved. Oxygen impurities in the nitriding environment were observed to play a significant role in the nitrided surface structures that formed, with detrimental effects for the Ni-Cr base alloys, but beneficial effects for the stainless steel alloy. Positive results from single-cell fuel cell testing are also ...

2007-11-15

121

Development of swing-free / shock free crane  

Energy Technology Data Exchange (ETDEWEB)

To develop the automatized crane and to apply the relevant technology to nuclear power plants, in this project and automatized crane control system is developed along with a swing and shock crane. Also, this technology has been transferred to Bando Machinery Co. Ltd. The drive mechanism of crane is designed by adopting vector drives which provide soft acceleration and deceleration characteristics. Also, radio modems and a long-range laser displacement sensor which are commercially available are introduced to accommodate the large scaled crane systems. Also, several devices are developed for the automation of crane system. These are a crane controller, a supervisory controller, a angle measuring device, and laser localizer, a drum grapple device, and crane supervisory program. The performance of developed crane system is revealed to rapidly reduce the residual swingof the transported object and precisely controls the object position in any case. ...

1999-04-01

122

Critical current measurements of high Tc superconductors in a scanning low temperature cryostat  

Energy Technology Data Exchange (ETDEWEB)

Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high {Tc} superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high {Tc} superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is ...

1991-01-01

123

Design of inductive sensors for tongue control system for computers and assistive devices  

British Library Electronic Table of Contents (United Kingdom)

Purpose. The paper introduces a novel design of air-core inductive sensors in printed circuit board (PCB) technology for a tongue control system. The tongue control system provides a quadriplegic person with a keyboard and a joystick type of mouse for interaction with a computer or for control of an assistive device. Method. Activation of inductive sensors was performed with a cylindrical, soft ferromagnetic material (activation unit). Comparative analysis of inductive sensors in PCB technology with existing hand-made inductive sensors was performed with respect to inductance, resistance, and sensitivity to activation when the activation unit was placed in the center of the sensor. Optimisation of the activation unit was performed in a finite element model. Results. PCBs with air-core indu...

2010-01-01

124

Beam direct converter with varying magnetic field  

Energy Technology Data Exchange (ETDEWEB)

The concept of a direct energy recovery system that applies a varying magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. The output beam energy and power of such an NNB will be {approximately}1 MeV and {approximately}1- MW/beam-line, respectively, and nearly the same amounts of positive- and negative-ion beams remain unneutralized in an NNB by using a gas-neutralizing cell. Therefore, the output of a beam direct convertor in an NNB is a bipolar direct current (dc) electric power with close to {plus_minus} 1 MV and several amperes if a conventional electrostatic or magnetostatic field is applied for ion beam separation. However, such high-voltage dc power is difficult to handle at the point of the regeneration of the power back to a commercial electric line because a very high voltage inverter tough enough to withstand occasional sparkdowns ...

1994-12-01

125

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

126

Viral RNA testing and automation on the bead-based CBNE detection microsystem.  

Energy Technology Data Exchange (ETDEWEB)

We developed prototype chemistry for nucleic acid hybridization on our bead-based diagnostics platform and we established an automatable bead handling protocol capable of 50 part-per-billion (ppb) sensitivity. We are working towards a platform capable of parallel, rapid (10 minute), raw sample testing for orthogonal (in this case nucleic acid and immunoassays) identification of biological (and other) threats in a single sensor microsystem. In this LDRD we developed the nucleic acid chemistry required for nucleic acid hybridization. Our goal is to place a non-cell associated RNA virus (Bovine Viral Diarrhea, BVD) on the beads for raw sample testing. This key pre-requisite to showing orthogonality (nucleic acid measurements can be performed in parallel with immunoassay measurements). Orthogonal detection dramatically reduces false positives. We chose BVD because our collaborators (UC-Davis) can supply samples from persistently infected animals; ...

2008-09-01

127

Focused ion beam lithography for rapid prototyping of metallic films  

International Nuclear Information System (INIS)

We present FIB-lithography methods for rapid and cost-effective prototyping of metal structures covering the deep-submicron- to the millimeter-range in a single lithography cycle. Focused ion beam (FIB) systems are widely used in semiconductor industry and research facilities for both analytical testing and prototyping. A typical application is to apply electrical contact to micron-sized sensors/particles by FIB induced metal deposition. However, as for E-beam lithography, patterning times for large area bonding pads are unacceptably long, resulting in cost-intensive prototyping. In this work, we optimized FIB lithography processing for negative and positive imaging mode to form metallic structures for large-areas down do the sub-100 nm range. For negative lithography features are defined by implanting Ga"+-ions into a commercial photo resist, without affecting the underlying structures by impinging ions. The structures are highly suitable for ...

2010-03-21

128

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

130

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

131

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

132

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

133

ch6-1 - NASA's History Office  

Science.gov (United States)

Composed of Sun sensors, the Canopus sensor, the inertial reference unit, ... The heart of the system was a 100-pound-thrust rocket whose hypergolic, ... The spacecraft's low-gain antenna picked up all incoming signals from the NASA-JPL ...

134

Roller Bearing Hot Box Sensor.  

Science.gov (United States)

A roller bearing hot box sensor utilizing a metallic temperature sensitive elongated wire element. The wire element contacts at temperatures in the range of about 125 F to about 225 F so that when the contraction movement of the wire is attached to a conn...

1982-01-01

135

PAS Domain of the Aer Redox Sensor Requires C-Terminal Residues for Native-Fold Formation and Flavin Adenine Dinucleotide Binding  

UK PubMed Central (United Kingdom)

The Aer protein in Escherichia coli is a membrane-bound, FAD-containing aerotaxis and energy sensor that putatively monitors the redox state of the electron transport system. Binding...Full Text Available

2004-10-01

136

N A S A T'ECHNICAL, - NASA Technical Reports Server  

Science.gov (United States)

Four temperature sensors were provided instead of the previous two sensors. 4. ... Incoming signals from either one or two ground stations at a frequency of .... The propulsion subsystem consists of a single solid-propellant rocket motor. ...

137

Microfluidic Devices Integrating Microcavity Surface-Plasmon-Resonance Sensors: Glucose Oxidase Binding-Activity Detection  

UK PubMed Central (United Kingdom)

We have developed miniature (≈1 μm diameter) microcavity surface-plasmon-resonance sensors (MSPRS), integrated them with microfluidics and tested...Full Text Available

2010-01-01

138

In-Space Propulsion Program Advanced Sensor Project - NASA  

Science.gov (United States)

Aug 25, 2004 ... Current Developments in Future Planetary Probe Sensors: .... Data: Outgoing and incoming EIA RS-422 interface for serial data transmission (for electrical purposes only, .... Milos, et. al, Journal of Spacecraft & Rockets 1999 ...

139

Structural, electronic and magnetic properties of splat-quenched FeCsub(x) alloys (x<0.05)  

International Nuclear Information System (INIS)

The results of a combined investigation of splat-quenched Fe-Csub(x) (x<0.05) alloys by resistivity, X-ray diffraction and Moessbauer spectroscopy are presented. The residual resistivity increases linearly with the carbon content (#DELTA#rho=5#mu##OMEGA#cm/at.%) with a slope identical to that observed in the dilute ferritic phase. X-ray diffraction reveals the presence of a martensite structure in addition to a small fraction of residual austenite; the dependence of the a and c lattice parameters on xsub(c) agrees with earlier measurements. A detailed investigation of the relative reflexion intensities shows that the as-quenched martensites consist of a mixing of massive martensite and tetragonal martensite for low carbon content and of tetragonal martensite only for xsub(c) approximately 0.05. The Moessbauer spectra reveal 3 or 4 magnetically non equivalent iron sites. From a detailed analysis of the intensity dependence of the subspectra on carbon content the ...

2006-01-01

140

Proton magnetic resonance spectroscopy reflects cellular proliferative activity in astrocytomas  

International Nuclear Information System (INIS)

We examined whether proton magnetic resonance spectroscopy (MRS) could provide accurate information on histological grade and cell proliferation in astrocytomas. We studied 23 patients with astrocytomas: five grade II, 10 grade III and eight with grade IV (glioblastoma multiforme). We performed proton MRS and determined the Ki-67 labeling index (LI), a tumour proliferation marker, in the same areas of the astrocytomas, and examined the statistical relationship between proton MRS and Ki-67 LI. The N-acetylaspartate (NAA)/creatine-phosphocreatine (Cr) and NAA/choline (Cho)-containing compound ratios were always significantly lower and the Cho/Cr ratios significantly higher than those for normal brain. The Cho/Cr ratio correlated positively and the NAA/Cho ratio inversely with Ki-67 LI. These findings suggest that the Cho signal in proton MRS reflects cellular proliferation. In Kaplan-Meier survival analysis, there was no significant difference ...

2000-05-01

141

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be ...

2004-01-01

142

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists ...

1991-09-15

145

Joint Sensor: Security Test and Evaluation Embedded in a ...  

Science.gov (United States)

... from theory to practice will be significantly reduced while intrinsically revolutionizing the approach to engineering network security architectures. ...

2010-12-01

146

Glory. - Glory - NASA  

Science.gov (United States)

based sensors, and a host of other scientific ... and change the balance between incoming and outgoing energy. ..... have launched on a larger rocket, flown in ...

147

Fundamentals for remote structural health monitoring of wind turbine blades - a pre-project. Annex B - Sensors and non-destructive testing methods for damage detection in wind turbine blades  

Energy Technology Data Exchange (ETDEWEB)

This annex provides a description of the sensor schemes and the non-destructive testing (NDT) methods that have been investigated in this project. Acoustic emission and fibre optic sensors are described in some detail whereas only the key features of well-established NDT methods are presented. Estimates of the cost of different sensor systems are given and the advantages and disadvantages of the different schemes is discussed. (au)

2002-05-01

148

FURTHER DEVELOPMENT OF THE AN/DMQ-9 ...  

Science.gov (United States)

... is disengaged from the spent rocket motor by a ... of the outbound and incoming modu- ... meteorological sensor and reference resistor is accomplished ...

1965-06-01

149

Conception, realization and test of an electronic Si-LiF-Si sensor for neutron spectrometry and dosimetry  

International Nuclear Information System (INIS)

The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)

1998-01-01

150

CRO-A, -B, -C Quicklook  

Science.gov (United States)

... and airborne sensors to track incoming ICBMs. The experiment was designed to determine how the intentional release of rocket propellants from an incoming ...

151

High-temperature ferromagnetism in laser-deposited layers of silicon and germanium doped with manganese or iron impurities  

Energy Technology Data Exchange (ETDEWEB)

The paper reports on the results of a study of the synthesis conditions effects on magnetic and transport properties of nanosized layers of high-T{sub c} diluted magnetic semiconductors (DMS), such as Ge:Mn, Si:Mn and Si:Fe, fabricated by laser-plasma deposition over a wide range of the growth temperature, T{sub g}=(20-550) deg. C on single-crystal GaAs or Al{sub 2}O{sub 3} substrates. Ferromagnetism of the layers was detected by measurement data of the magneto-optical Kerr effect, anomalous Hall effect, negative magnetoresistance and ferromagnetic resonance (FMR) at 5-500 K. The optimum growth temperature, T{sub g}, for Si:Mn/GaAs layers with T{sub c}{approx}400 K is shown to be about 400 deg. C. The Si:Mn/Al{sub 2}O{sub 3} layers with 35% of Mn have the metal-type of conductivity with manifestation of magnetization up to room temperature. Different types of uniformly doped structures and digital alloys have been ...

2009-04-15

152

First principle calculation on the electronic structure of the copper (II)-azido compound [#left brace#Cu(L)(N_3)_2#right brace#_n] (L=benzylamine)  

International Nuclear Information System (INIS)

Cu"2"+ ions are alternatively bridged by end-on and asymmetrical end-to-end (EE) azido groups in copper (II)-azido compound [#left brace#Cu(L)(N_3)_2#right brace#_n] (L=benzylamine). The electronic structure of its ferromagnetic ground state has been calculated using the self-consistent full-potential linearized augmented plane wave method based on the density functional theory. The spin populations have been found to be strongly positive on the Cu"2"+ ions, weakly positive on the terminal nitrogen atoms of the azido groups as well as on the nitrogen atoms of the benzylamine, and feeble on the central nitrogen atoms of the azido groups. Based on the spin distribution obtained from calculation, the ferromagnetic coupling through the azido groups has been analyzed as resulting from a spin delocalization from the Cu"2"+ ions toward the azido groups. But the result also indicates that the spin polarization effect may also take part in the ...

2005-03-01

153

Diagnosis of breast cancer with MR imaging using the magnetization transfer contrast and a newly-developed breast surface coil for the supine position  

Energy Technology Data Exchange (ETDEWEB)

We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation (CE+)) methods and the lesions using the SPGR (CE+) method after ...

1998-09-01

154

Design of the ZTH vacuum liner  

Energy Technology Data Exchange (ETDEWEB)

The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between pairs of the 16 diagnostic stations to ...

1987-01-01

155

Construction and Calibration of the Laser Alignment System for the CMS Tracker  

CERN Document Server

The CMS detector (Compact Muon Solenoid) is under construction at one of the four proton-proton interaction points of the LHC (Large Hadron Collider) at CERN, the European Organization for Nuclear Research (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 m and a length of 5.4 m representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 m2 to detect charged particles from proton collisions. They are placed on a rigid carbon fibre structure, providing stability within the working conditions of a 4 T solenoid magnetic field at ?10oC. Knowledge of the position of the silicon detectors at the level of 100 ?m is needed for an efficient pattern recognition of charged particle tracks. Metrology methods are used to survey tracker subdetectors and the integrated Laser Alignment System (LAS) provides absolute ...

2006-01-01

156

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

157

Real-time orbit feedback at the APS.  

Energy Technology Data Exchange (ETDEWEB)

A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the underlying orbit ...

1998-06-18

158

Multiple resonances and Coulomb blockade splitting in a quantum dot-DNA composite  

British Library Electronic Table of Contents (United Kingdom)

Inspired by the recent realizations of quantum dot (QD)-DNA conjugation, we study the spectral density of a magnetic impurity coupled to a mesoscopic semiconducting host. Using a combination of exact diagonalization technique and an analytic approach, we demonstrate that various types of resonances occur according to the relative position of impurity levels (IL) with respect to the host levels (HL). While the usual Coulomb peaks appear when the IL lie inside a band gap, with IL approaching HL and hybridization activated, they shift nonlinearly with the repulsion strength and even undergo splitting for a strong hybridization. When IL merge into HL, multiple resonances of a comblike structure are found along with a parity effect.

2011-01-01

159

Calculation of electromagnetic force in electromagnetic forming process of metal sheet  

International Nuclear Information System (INIS)

Electromagnetic forming (EMF) is a forming process that relies on the inductive electromagnetic force to deform metallic workpiece at high speed. Calculation of the electromagnetic force is essential to understand the EMF process. However, accurate calculation requires complex numerical solution, in which the coupling between the electromagnetic process and the deformation of workpiece needs be considered. In this paper, an appropriate formula has been developed to calculate the electromagnetic force in metal work-piece in the sheet EMF process. The effects of the geometric size of coil, the material properties, and the parameters of discharge circuit on electromagnetic force are taken into consideration. Through the formula, the electromagnetic force at different time and in different positions of the workpiece can be predicted. The calculated electromagnetic force and magnetic field are in good agreement with the numerical and experimental ...

2010-06-15

160

A low-temperature calorimetric study of synthetic (forsterite+fayalite) {(Mg2SiO4+Fe2SiO4)} solid solutions: An analysis of vibrational, magnetic, and electronic contributions to the molar heat capacity and entropy of mixing  

International Nuclear Information System (INIS)

The molar heat capacities (Cp,m) of a series of synthetic forsterite (Fo)-fayalite (Fa), (Mg2SiO4+Fe2SiO4), olivines have been measured between 5K and 300K on milligram-sized samples with the Physical Properties Measurement System (Quantum Design(R)). Sharp, ?-type heat capacity anomalies are observed in the Fe-rich compositions fayalite, Fo10Fa90, Fo20Fa80, Fo30Fa70, and Fo40Fa60. The corresponding Neel temperatures TN decrease linearly from 64.5K in fayalite to 32.8K in Fo40Fa60 following the relationship TN=79.02.xFa-14.07. Fo50Fa50 and Mg-richer olivines show weak broad features in the heat capacity data around 15K to 20K that decrease in magnitude with increasing forsterite content. In order to derive and separate molar electronic, magnetic and vibrational heat capacity contributions, Cel,m, Cmag,m, and Cvib,m from the experimental heat capacities (Ctot,m), we used a single-parametric phonon dispersion model to calculate Cvib,m for the solid-solution members ...

2007-06-01

161

Extended range chemical sensing apparatus  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for sensing chemicals over extended range of concentrations. In particular, first and second sensors each having separate, but overlapping ranges for sensing concentrations of hydrogen are provided. Preferably, the first sensor is a MOS solid state device wherein the metal electrode or gate is a nickel alloy. The second sensor is a chemiresistor comprising a nickel alloy.

1994-01-01

162

Gas sensor arrays (electronic noses) and their combination with trap techniques  

Energy Technology Data Exchange (ETDEWEB)

In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)

2001-07-01

163

Electrogenerated Chemiluminescence Sensor Based on Tris(2,2prime-bipyridine)ruthenium(II)-Immobilized Natural Clay and Ionic Liquid  

British Library Electronic Table of Contents (United Kingdom)

A novel electrogenerated chemiluminescence (ECL) sensor based on natural clay and ionic liquid was fabricated. Tris(2,2prime-bipyridine)ruthenium(II) (Ru(bpy)32+) was immobilized on natural clay surface through simple adsorption. An ECL sensor was prepared by mixing Ru(bpy)32+-incorporated clay, graphite powder and an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) as the binder. The electrochemical behavior and ECL of the immobilized Ru(bpy)32+ was investigated. It was observed that the ECL of immobilized Ru(bpy)32+ was activated by the ionic liquid. The proposed ECL sensor showed high sensitivity to tri-n-propylamine (TPrA) and the detection limit was found to be 20 pM. In addition, the ECL sensor displayed good stability for TPrA detection and long-term storage stability.

2010-01-01

164

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

165

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

166

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

167

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

168

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

170

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

171

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

173

Development of a system for the observation of the stable operation in multi stage axial compressors. Final report; Erprobung und Weiterentwicklung eines Messsystems zur Stabilitaetsueberwachung im Verdichter einer HTGT. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

This report describes work carried out in the context of TurboTech Interim for the development of a system for monitoring stationary gas turbines for approaching the stability limit of the compressor. The requirements for the system components were defined and the suitability of different types and positions of pressure sensors were examined and evaluated. It was found very early in the work that, due to the complexity of the object being monitored, one would not succeed in finding a simple criterion for monitoring the pump limit. Rather, apart from the selection of suitable sensors and optimum positions, one must analyse the present signals in different ways and create a decision matrix from this. Existing work on this subject is mostly concerned with the phenomena in the context of experiments on experimental compressors or is not suitable for the requirements of stationary industrial gas turbines. ...

1996-12-31

174

Bootstrapping Key Pre-Distribution: Secure, Scalable and User-Friendly Initialization of Sensor Nodes  

CERN Document Server

To establish secure (point-to-point and/or broadcast) communication channels among the nodes of a wireless sensor network is a fundamental task. To this end, a plethora of (socalled) key pre-distribution schemes have been proposed in the past. All these schemes, however, rely on shared secret(s), which are assumed to be somehow pre-loaded onto the sensor nodes. In this paper, we propose a novel method for secure initialization of sensor nodes based on a visual out-of-band channel. Using the proposed method, the administrator of a sensor network can distribute keys onto the sensor nodes, necessary to bootstrap key pre-distribution. Our secure initialization method requires only a little extra cost, is efficient and scalable with respect to the number of sensor nodes. Moreover, based on a usability study that we conducted, the method turns out to be quite ...

2008-01-01

175

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...

2009-03-01

176

Resolution studies of a GEM-based TPC  

Energy Technology Data Exchange (ETDEWEB)

Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the hodoscope allows systematic studies of ...

2006-12-15

177

Self-consistent full-potential linearized-augmented-plane-wave local-density electronic-structure studies of magnetism and superconductivity in C15 compounds: ZrZn_2 and ZrV_2  

International Nuclear Information System (INIS)

The electronic structure and properties of the cubic Laves phase (C15) compounds ZrZn_2 and ZrV_2 have been determined using our all-electron full-potential linearized-augmented-plane-wave (FLAPW) method for bulk solids. The computations were performed in two stages: (i) self-consistent warped muffin tin and (ii) self-consistent full potential. Spin-orbit coupling was included after either stage. The effects of the inclusion of the nonspherical terms inside the muffin tins on the eigenvalues is found to be small (of order 1 mRy). However, due to the fact that some of the bands near the Fermi level are flat, this effect leads to a much higher value of the density of states at E/sub F/ in ZnZr_2. The most important difference between the materials ZrZn_2 and ZrV_2 is the position of the d bands derived from the Zr and V atoms. Consequently, these materials have completely different Fermi surfaces. We have investigated the magnetic properties of ...

178

Self-consistent full-potential linearized-augmented-plane-wave local-density electronic-structure studies of magnetism and superconductivity in C15 compounds: ZrZn/sub 2/ and ZrV/sub 2/  

Energy Technology Data Exchange (ETDEWEB)

The electronic structure and properties of the cubic Laves phase (C15) compounds ZrZn/sub 2/ and ZrV/sub 2/ have been determined using our all-electron full-potential linearized-augmented-plane-wave (FLAPW) method for bulk solids. The computations were performed in two stages: (i) self-consistent warped muffin tin and (ii) self-consistent full potential. Spin-orbit coupling was included after either stage. The effects of the inclusion of the nonspherical terms inside the muffin tins on the eigenvalues is found to be small (of order 1 mRy). However, due to the fact that some of the bands near the Fermi level are flat, this effect leads to a much higher value of the density of states at E/sub F/ in ZnZr/sub 2/. The most important difference between the materials ZrZn/sub 2/ and ZrV/sub 2/ is the position of the d bands derived from the Zr and V atoms. Consequently, these materials have completely different Fermi surfaces. We have investigated the ...

1988-03-01

179

On the calculation of scattered fields by 3-D structure in the time-domain electromagnetic (TDEM) method; Jikan ryoiki denjiho ni okeru sanjigen kozo kara no sanranba no keisan ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the calculation method of 3-D underground structures in TDME method which measures only field components. Recently, FDTD method was developed as calculation method in time domain difference calculus, and the forward analysis accuracy of 3-D fields was rapidly improved. The survey results using a large-scale loop (600m{times}360m) were numerically analyzed by FDTD method. 16 measuring lines were prepared in both X and Y directions, and measuring points were prepared on intersection points of the measuring lines. Since signal current is staircase one, step and impulse responses of the ground were determined by calculating magnetic field and its time differentiation. The rectangular body (120m{times}120m{times}100m) of 0.2S/m in conductivity (5 ohm m in resistivity) was installed 160m under the ground as 3-D resistivity anomaly. The ground of 0.01S/m (100 ohm m) was assumed. Time variation in horizontal magnetic field vector ...

1996-10-01

180

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and the variations in uniformity were unique ...

1984-06-05

181

Monthly report of activities: APRIL 1, 1969  

Science.gov (United States)

This is the first of a series of monthly reports summarizing the status of the work of the National Accelerator Laboratory. This first report will cover developments since the publication of the Design Report in January. Authorization hearings were held before the Joint Committee on Atomic Energy on February 21, 1968. Dr. Wilson described the plans and designs of the Laboratory. The present plan of the Laboratory is that the Village of Weston will be utilized for office, laboratory, and shop space during construction. The Laboratory business office is already occupying several houses. The linac section is occupying three houses for offices and construction of an 8,000 sq ft laboratory building for linac work is almost complete. Another house is being used and a 4,500 sq ft inflatable building is being constructed for model-magnet and vacuum testing. Other temporary buildings will be constructed for use by other sections. We plan to move into the village as rapidly ...

1968-04-01

182

Global orbit corrections  

Energy Technology Data Exchange (ETDEWEB)

There are various reasons for preferring local (e.g., three bump) orbit correction methods to global corrections. One is the difficulty of solving the mN equations for the required mN correcting bumps, where N is the number of superperiods and m is the number of bumps per superperiod. The latter is not a valid reason for avoiding global corrections, since, we can take advantage of the superperiod symmetry to reduce the mN simultaneous equations to N separate problems, each involving only m simultaneous equations. Previously, I have shown how to solve the general problem when the machine contains unknown magnet errors of known probability distribution; we made measurements of known precision of the orbit displacements at a set of points, and we wish to apply correcting bumps to minimize the weighted rms orbit deviations. In this report, we will consider two simpler problems, using similar methods. We consider the case when we make M beam ...

1987-11-01

183

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...

1981-11-11

185

Magnetic braking of the rotation of molecular cloud cores  

International Nuclear Information System (INIS)

We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).

186

LHC magnet alignment  

CERN Document Server

Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.

2007-01-01

187

Using fiber optic sensors to protect intake, outflow, and other environmentally exposed openings  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on the protection of opening that are exposed to the environment in nuclear facilities which presents an almost overwhelming engineering challenge. Intakes and outflows must permit the passage of large volumes of air or water without impeding their flow, and they are often exposed to corrosive salt and chemicals. An intrusion detection sensor that is intended to protect these openings must be capable of operating reliably under environmentally harsh conditions, and at the same time either provide a physical delay barrier or attach to an existing barrier. A new fiber optic sensor technology has now been developed specifically for protecting environmentally exposed openings. This sensor uses a fiber optic cable embedded in a neoprene rubber frame which is reinforced with Kevlar threads or braided steel cable. The sensor is configured in a mesh pattern with openings sufficiently large to ...

1991-01-01

188

The design and performance of a capacitance sensor for two-phase flow concentration measurements in a square duct  

Energy Technology Data Exchange (ETDEWEB)

The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good ...

1995-12-31

189

Rotation seismic sensor and its calibration; Kaiten seibun jishinkei no shisaku to kando no kentei  

Energy Technology Data Exchange (ETDEWEB)

Sensor has been developed for the measurement of seismic wave rotary components. The vertical axis rotary component sensor is constituted of four L22Ds, similar to each other in performance, fixed in a ring formation on a metal bed. The ring is 22cm in diameter, and the four coils are connected so that their outputs will be added up. A horizontal axis rotary component sensor is built in the similar way. The rotary component sensors are all connected to a spectrum analyzer for the measurement of micromotions. It is found that the four-L22D combination can detect a rotary component of 335mV/deg/s. The sensor can detect both vertical and horizontal components with roughly the same sensitivity. A ring-form combination of conventional electromagnetic seismometers, though only as a temporary expedient, can perform high-resolution detection of rotary components and determine the absolute ...

1997-05-27

190

Life Under Your Feet: An End-to-End Soil Ecology Sensor Network, Database, Web Server, and Analysis Service  

CERN Document Server

Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented temporal precision. ...

2007-01-01

191

Differential pressure measurement using a free-flying insect-like ornithopter with an MEMS sensor  

International Nuclear Information System (INIS)

This paper presents direct measurements of the aerodynamic forces on the wing of a free-flying, insect-like ornithopter that was modeled on a hawk moth (Manduca sexta). A micro differential pressure sensor was fabricated with micro electro mechanical systems (MEMS) technology and attached to the wing of the ornithopter. The sensor chip was less than 0.1% of the wing area. The mass of the sensor chip was 2.0 mg, which was less than 1% of the wing mass. Thus, the sensor was both small and light in comparison with the wing, resulting in a measurement system that had a minimal impact on the aerodynamics of the wing. With this sensor, the 'pressure coefficient' of the ornithopter wing was measured during both steady airflow and actual free flight. The maximum pressure coefficient observed for steady airflow conditions was 1.4 at an angle of attack of 30"0. In flapping flight, the ...

2010-09-01

192

A Risk-Based Sensor Placement Methodology  

Energy Technology Data Exchange (ETDEWEB)

A risk-based sensor placement methodology is proposed to solve the problem of optimal location of sensors or detectors to protect population against the exposure to and effects of known and/or postulated chemical, biological, and/or radiological threats. Risk is calculated as a quantitative value representing population at risk from exposure against standard exposure levels. Historical meteorological data are used to characterize weather conditions as the frequency of wind speed and direction pairs. The meteorological data drive atmospheric transport and dispersion modeling of the threats, the results of which are used to calculate risk values. Sensor locations are determined via an iterative dynamic programming algorithm whereby threats captured or detected by sensors placed in prior stages are removed from consideration in subsequent stages. In addition to the risk-based placement algorithm, the ...

2008-10-01

193

Density separation of materials by using magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...

1980-03-01

194

On the Generation of a Robust Residual for Closed-loopControl systems that Exhibit Sensor Faults  

DEFF Research Database (Denmark)

This paper presents a novel design methodology, based on shaping the system frequency response, for the generation of an appropriate residual signal that is sensitive to sensor faults in the presence of model uncertainty and exogenous unknown (unmeasured) disturbances. An integrated feedback controller design and robust frequency-based fault detection approach is proposed for Single-Input/Single-Output systems. The effciency of the proposed method is demonstrated on a Single Machine Innite Bus (SMIB) power system that achieves a coordinate power system stabilizer with satisfactory sensor fault detection capabilities.

2007-01-01

195

entityTools 1.0  

Science.gov (United States)

Systems MEMS sensors C11-20 Lifetime Distributions of Aluminum Electrolytic Capacitors C11-22 Adhesion Strength of Advanced Polymer Films for Flexible and Rigid...

2011-03-15

196

chapter 5 - NASA's History Office  

Science.gov (United States)

Ever-present water vapor and dust distort or block incoming radiations. ... were among the first scientific sensors to be attached to the earliest space rockets. ...

197

ch4  

Science.gov (United States)

Earlier studies had concluded that the preferred direction of the rocket nozzle should ..... Center had to redesign the sensor canisters, brackets and cable supports. ... depending on inspection of the quality of the incoming pictures in real-time. ...

198

Tris(2,2prime-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films  

British Library Electronic Table of Contents (United Kingdom)

A highly sensitive and stable tris(2,2prime-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)32+ immobilized in the ECL sensor by adsorption of Ru(bpy)32+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-...

2006-01-01

199

Tightly Integrating Optical And Inertial Sensors For Navigation ...  

Science.gov (United States)

... 13 2.4 Inertial Navigation Error Model . . . . . ... sources such as electrical noise, thermal noise, etc. 2.4 Inertial Navigation Error Model ...

2008-03-01

200

Surface and Interface Study of PdCr/SiC Schottky Diode Gas Sensor ...  

Science.gov (United States)

indications of the formation of palladium silicides. 2, 4. It has been reported .... At room temperature, palladium silicides formed in a relatively narrow interface ...

201

Space shuttle Discovery scheduled to launch Aug. 25 from Kennedy ...  

Science.gov (United States)

Aug 20, 2009 ... gratings, used to precisely determine the energies of incoming ..... The rocket is wired throughout with more than 700 sensors ...

202

Space Science - NASA Headquarters  

Science.gov (United States)

Canada will provide telescope baffles and fine error sensor assemblies. ..... ( Ongoing) Flight tests aboard sounding rockets and balloon planned for FY 1995. .... the effects of incoming energetic particles and solar radiation on the ...

203

Sigma-Point Kalman Filter Based Sensor Integration ...  

Science.gov (United States)

... is the extended Kalman filter (EKF ... Kalman filters called sigma-point Kalman filters ... INFERENCE, *KALMAN FILTERING, *DRONES, *SITUATIONAL ...

2004-10-25

204

Satellite Calibration Data. Annual Data Report - 1977  

Science.gov (United States)

... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...

1979-08-01

205

SPASE Resource Description - the VHO - NASA  

Science.gov (United States)

The potentials of the spherical sensor and nearby conductors are controlled by ... Incoming data are continuously monitored by algorithms in the software to ... launched together with FM5 (Rumba) by a Soyuz-Fregat rocket from Baikonur. ...

206

Remote Sensor Systems for Unmanned Planetary Missions  

Science.gov (United States)

instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...

207

Remote Sensing Tutorial ... - The Remote Sensing Tutorial - NASA  

Science.gov (United States)

The first space photographs were obtained from V-2 rockets fired upwards from the ..... Some fraction of the incoming solar radiation is reflected towards a sensor ...

208

Real-Time Diagnostics for a Reusable Rocket Engine - NASA ...  

Science.gov (United States)

of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...

209

NOx Sensor Development  

Energy Technology Data Exchange (ETDEWEB)

NO{sub x} compounds, specifically NO and NO{sub 2}, are pollutants and potent greenhouse gases. Compact and inexpensive NO{sub x} sensors are necessary in the next generation of diesel (CIDI) automobiles to meet government emission requirements and enable the more rapid introduction of more efficient, higher fuel economy CIDI vehicles. Because the need for a NO{sub x} sensor is recent and the performance requirements are extremely challenging, most are still in the development phase. Currently, there is only one type of NO{sub x} sensor that is sold commercially, and it seems unlikely to meet more stringent future emission requirements. Automotive exhaust sensor development has focused on solid-state electrochemical technology, which has proven to be robust for in-situ operation in harsh, high-temperature environments (e.g., the oxygen stoichiometric sensor). Solid-state ...

2010-11-01

210

NEX - Analysis of ENSO Dynamics and ThermoDynamics in the ... - NASA  

Science.gov (United States)

Analysis of ENSO Dynamics and ThermoDynamics in the Western Pacific Warm Pool - An Application of Multi-Sensor Satellite Observations. ...

211

Measured Temperatures of Solid Rocket Motors Dump Stored ...  

Science.gov (United States)

... TARGET SENSOR-MK 80 SERIES BOMBS ... 5-inch-, and 2.75-inch- diameter rocket motors that ... balance when compared to incoming solar radiation ...

1989-07-01

212

Information Fusion and Extraction Priorities for Australia's ...  

Science.gov (United States)

... the open source OpenMap Java toolkit from BBN ... 2001), Handbook of Multisensor Data Fusion ... Oxenham (2002), Sensor Registration Using Airlanes ...

2004-03-01

213

Fusion of Imaging and Inertial Sensors for Navigation  

Science.gov (United States)

... 2.5.6 Development of Observation Equations . . . . . 25 2.6 Inertial Navigation Error Model . . . . . ... 2 , as expected. 2.6 Inertial Navigation Error Model ...

2006-09-01

214

Development of a Transpondersonde for the Super-LOKI ...  

Science.gov (United States)

... The three meteorological rocket systems, in order of ... IC3 and IC4 divides the incoming clock pulses f ... at the junction of the temperature sensor and R ...

1972-02-02

215

Desensitized Optimal Filtering and Sensor Fusion Tool Kit  

Science.gov (United States)

Sep 18, 2009 ... It is proposed to develop desensitized optimal filtering ... in robust and/or adaptive generalized Kalman and Sigma-Point filters for ...

216

Deep Space Probe Science Experiment  

Science.gov (United States)

Briefly, 48 MOS microparticle sensors (essentially the same as those flown on .... at the Naval Research Lab to interpret the polarization of the incoming radio .... Adapter Satellite, to be published in Journal of Spacecraft and Rockets, 1994. ...

217

Data Sets for Data Group PEM - Mirador - NASA  

Science.gov (United States)

Nov 5, 2010 ... PEM. The Particle Environment Monitor measures the type, amount, energy, ... info, Daily PEM HEPS and MEPS data at the original sensor ...

218

Data - SPASE Resource Description  

Science.gov (United States)

Feb 23, 2011 ... The potentials of the spherical sensor and nearby conductors are ... Incoming data are continuously monitored by algorithms in the software to ..... together with FM6 (Salsa) by a Soyuz-Fregat rocket from Baikonur. ...

219

DMSP Special Sensor Microwave/Imager Calibration ...  

Science.gov (United States)

... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...

2011-05-14

220

Common aperture multispectral sensor flight test program  

Energy Technology Data Exchange (ETDEWEB)

This paper will provide an overview of the Common Aperture Multispectral Sensor (CAMS) Hardware Demonstrator. CAMS is a linescanning sensor that simultaneously collected digital imagery over the Far-IR (8 to 12 {mu}m) and visible spectral (0.55 to 1.1 PM) spectral bands, correlated at the pixel level. CAMS was initially sponsored by the U.S. Naval Air System Commands F/A-18 program office (PMA-265). The current CAMS field tests are under the direction of Northrop-Grumman for the Defense Nuclear Agency (DNA) in support of the Follow-On Open Skies Sensor Evaluation Program (FOSEP) and are scheduled to be conducted in April 1996. 8 figs., 4 tabs.

1996-11-01

221

Center for Advanced Sensors Year Two Funding (FY2006)  

Science.gov (United States)

... a Networked Embedded Sensing Toolkit (MSR Sense ... edging due to mis-registration than the ... Langrebe, Signal theory in multisensor remote sensing ...

2008-02-26

222

April 15 02 - NASA  

Science.gov (United States)

Nov 13, 2006 ... Indicator Experiment (TIE) consists of a wideband sensor to gather radar, ... November 10 at Shore Memorial. Hospital in Nassawadox, Va. ...

223

An Optical Fiber Infrasound Sensor  

Science.gov (United States)

... We use a compliant, sealed tube helically wrapped with an optical fiber. ... 2.5 cm diameter compliant, sealed tube 10 m < length < 120 m ...

2000-09-01

225

Physical and optical properties of rare earth cobalt magnets  

Energy Technology Data Exchange (ETDEWEB)

Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.

1980-08-01

231

METHOD OF FORMING THIN MAGNETIC FILM  

J-STORE (Japan)

Full Text Available

2007-10-04

236

NASA TECH BRIEF  

Science.gov (United States)

Magnetic Forming Studies. The use of transient high magnetic-field devices has made possible the generation of very large accurately ...

238

Magnetic properties of single crystalline RE_2PdSi_3 intermetallic compounds  

International Nuclear Information System (INIS)

... susceptibility magnetization magnetoresistance monocrystals order-disorder

239

Finite Element Analysis of Magnetoelastic Plate Problems.  

Science.gov (United States)

... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...

1981-08-01

240

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

241

An investigation of the decoupling effects in a magnetic forming beryllium coil assembly.  

Science.gov (United States)

Decoupling force exerted by magnetic forming Be coil assembly on metallic plate during forming

1968-01-01

243

Progress of magnetic-suspension systems and magnetic bearings in the USSR  

International Nuclear Information System (INIS)

This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.

1992-05-01

244

Synthesis, characterization and biological evaluation of mononuclear Co(II), Ni(II), Cu(II) and Pd(II) complexes with new N2O2 Schiff base ligands.  

Science.gov (United States)

New tetradentate N(2)O(2) donor Schiff bases and their mononuclear Co(II), Ni(II), Cu(II), and Pd(II) complexes were synthesized and characterized extensively by IR, (1)H-, (13)C-NMR, mass, ESR, conductivity measurements, elemental and thermal analysis. Specifically the magnetic and electronic spectral measurements demonstrate the octahedral structures of cobalt(II), nickel(II) complexes and square planar geometries of copper(II), palladium(II) complexes. All the ligands and complexes were screened for their in vitro antibacterial activity against two gram-positive bacteria (Bacillus subtilis, Staphylococcus aureus) and two gram-negative bacteria (Escherichia coli, Klebsiella pneumonia). In this study, Pd(II) complexes exhibited potent antibacterial activity against B. subtilis, S. aureus whereas other metal complexes also exerted good activity towards all tested strains even than standard drugs streptomycin and ampicillin. PMID:21297294

2011-02-01

245

Results of Compact Stellarator Engineering Trade Studies  

Energy Technology Data Exchange (ETDEWEB)

number of technical requirements and performance criteria can drive stellarator costs, e.g., tight tolerances, accurate coil positioning, low aspect ratio (compactness), choice of assembly strategy, metrology, and complexity of the stellarator coil geometry. With the completion of a seven-year design and construction effort of the National Compact Stellarator Experiment (NCSX) it is useful to interject the NCSX experience along with the collective experiences of the NCSX stellarator community to improving the stellarator configuration. Can improvements in maintenance be achieved by altering the stellarator magnet configuration with changes in the coil shape or with the combination of trim coils? Can a mechanical configuration be identified that incorporates a partial set of shaped fixed stellarator coils along with some removable coil set to enhance the overall machine maintenance? Are there other approaches that will simplify the concepts, ...

2009-05-27

246

Results of Compact Stellarator Eengineering Trade Studies  

Energy Technology Data Exchange (ETDEWEB)

A number of technical requirements and performance criteria can drive stellarator costs, e.g., tight tolerances, accurate coil positioning, low aspect ratio (compactness), choice of assembly strategy, metrology, and complexity of the stellarator coil geometry. With the completion of a seven-year design and construction effort of the National Compact Stellarator Experiment (NCSX) it is useful to interject the NCSX experience along with the collective experiences of the NCSX stellarator community to improving the stellarator configuration. Can improvements in maintenance be achieved by altering the stellarator magnet configuration with changes in the coil shape or with the combination of trim coils? Can a mechanical configuration be identified that incorporates a partial set of shaped fixed stellarator coils along with some removable coil set to enhance the overall machine maintenance? Are there other approaches that will simplify the concepts, ...

2009-09-25

247

Potential anti fungal agents. Synthesis and activity of 2-alkylthiopyridine-4-carbothioamides  

Energy Technology Data Exchange (ETDEWEB)

A series of 2-alkylthiopyrine-4-carbothioamides were synthesized, and their anti-fungal potency was tested. The chemical structures were proved by infrared spectroscopy (IR) and {sup 1}H nuclear magnetic resonance ({sup 1}H-NMR) data and by elemental analysis. The minimal inhibitory concentration (MIC) and minimal fungicidal concentration (MFC) assessment were used for the estimation of potential activity in vitro. The study comprising 21 clinical isolates of fungi showed that two compounds exhibited fair inhibitory activity against some yeasts and dermatophytes. Selective fungistatic activity against non-dermatophytes (MIC = 3.12-25.0 {mu}g/mL) was found also in another compound. None of the above compounds showed inhibitory activity against non-dermatophyte filamentous fungi. Microbiological activity of 2-alkylthiopyridine-4-carbothioamides appears to be mainly related to hydrophobicity of alkyl in position 2. (authors). 10 refs., 8 tabs.

1996-05-01

248

Positive pulsed corona discharge process for simultaneous removal of SO{sub 2} and NO{sub x} from iron-ore sintering flue gas  

Energy Technology Data Exchange (ETDEWEB)

The authors investigated the application of pulsed corona discharge process to the removal of SO{sub 2} and NO{sub x} from industrial flue gas of an ioron-ore sintering plant. This study was performed on a pilot scale, which is the most advanced demonstration of this process. The flow rate of 5000 m{sup 3}/h of the flue gas was successfully treated. The electrode structure of the corona reactor is the same with that of conventional electrostatic precipitator. The authors made use of magnetic pulse compression technology to produce repetitive high voltage pulse. Pulse width (full width at half maximum) was reduced to less than 1 {micro}s by connecting a resister in parallel with the corona reactor. An inductor was added to the resister in series to minimize the loss by restricting the current flowing through the resister. By this way, they were able to deliver pulse power with peak voltage of 110 kV and peak current of 2.3 kA to the corona reactor. Chemical ...

1999-08-01

249

Nuclear resonant spectroscopy at Bragg reflections from periodic multilayers: Basic effects and applications  

Science.gov (United States)

A systematic study of the Bragg nuclear resonant reflectivity from periodic multilayers in the energy and time domains is presented. Using the kinematical approach of the general reflectivity theory we describe the basic features of the time evolution of the reflected wave after a pulsed excitation of resonant multilayers by synchrotron radiation. Effects of the collective excitation have been examined such as the shift of quantum beat phases, the interplay between electronic and nuclear subsystem excitations depending on their relative position in a multilayer, the energy and time evolution of standing waves inside a resonant multilayer, and their influence on the reflectivity spectra. The exact expression for the reflectivity by a thin resonant layer placed inside a multilayer structure has been derived. The observed shift of the delayed reflectivity Bragg peak relative to the prompt peak is explained by the developed formalism. Experimental applications are ...

2005-09-15

250

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D ...

2008-04-15

251

Electromagnetic fields and cancer: how ICNIRP has dealt with the issue  

International Nuclear Information System (INIS)

Whether exposure to electromagnetic fields (EMFs) cause cancer has been vigorously debated for many years and has been the most vexing issue with which ICNIRP has had to deal during its short existence. There have been three parts of the electromagnetic spectrum that the issue of cancer has raised: static (0 Hz) magnetic fields, extremely low frequency (ELF) fields (defined as > 0-300 Hz, but concerns have been raised almost exclusively at the power frequencies of 50/60 Hz), and radiofrequency (RF) fields (300 Hz -300 GHz). By far the major problems have arisen during the construction of new high voltage transmission lines and mobile telephone systems. Actions by protest groups concerned with possible health effects, especially with cancer in children, has now reached such a scale that it is costing electrical utilities and communications companies billions of dollars annually world-wide. With such high stakes, ICNIRP has had to be extremely careful in its ...

1996-04-01

252

Early effects of boron neutron capture therapy on rat glioma models  

International Nuclear Information System (INIS)

Early effects of boron neutron capture therapy (BNCT) on malignant glioma are characterized by reduction of the enhancement area and regression of the peritumoral edema radiologically. The aim of this study was to investigate the early histological changes of tumors and inflammatory cells after BNCT in the rat brain. Rats were treated with BNCT using boronophenylalanine (BPA) 7 days after implantation of C6 glioma cells. The tumors were assessed with magnetic resonance imaging and histopathological examination at 4 days after BNCT. The mean tumor volumes were 39#+-#2 mm"3 in the BNCT group and 134#+-#18 mm"3 in the control group. In the BNCT group, tumor cells showed a less pleomorphic appearance with atypical nuclei and mitotic figures. The Ki-67 labeling index was 6.5%#+-#4.7% in the BNCT and 35%#+-#3.8% in the control group. The reactions of the inflammatory cells were examined with ED-1 as macrophage marker and OX42 as microglia marker. ED-1- and ...

253

Active SWD using monochromatic source wavelet; Tan`itsu shuhasu no shingen hakei wo mochiita active SWD  

Energy Technology Data Exchange (ETDEWEB)

As part of developing efforts for physical exploration technologies for oil reservoirs, this paper describes development of an active seismic while drilling (SWD). The SWD is a seismic exploration method to acquire records equivalent to VSP using seismic waves generated from a bit executing excavation, and is capable of detection and control on a real time basis during the excavation. However, the drawback is that it is subjected to a limitation in the bit. To eliminate this limitation, an artificial seismic source method was devised. In other words, this is an SWD utilizing an artificial seismic source. The contrivance is such that a shot sub containing a magnetic distortion oscillator is attached directly above a bit to generate vibration artificially, and try to utilize larger seismic energy by combining this vibration with that generated from the excavating bit. Frequency band in the seismic source is as narrow as nearly a single frequency waveform. Preparing a ...

1997-05-27

254

A fluorescent aminolipid from a green photosynthetic bacterium  

Energy Technology Data Exchange (ETDEWEB)

A preliminary chemical characterization is presented of phosphate-free aminolipids isolation from Chlorobium limicola f. thiosulfatophilum. The lipid contains no phosphorus, glycerol, sugar, ornithine, or lysine. Ultraviolet absorption and fluorescence spectra indicate that the amino moiety of the lipid is an aromatic heterocyclic compound. Infrared spectra indicate that the lipid is a secondary or tertiary amide, and gas chromatograhic analysis of the hydrolyzed lipid shows that for each 1100 g of lipid, 1 mol of myristic acid (C/sub 14:0/) is linked in an amide bond. Acid hydrolysis of the lipid yields two fluorescent substances, A (ninhydrine positive) and B (negative), in addition to myristic acid. Proton nuclear magnetic resonance (NMR) studies indicate that substance A contains a butyl groups attached to a conjugated ring carbon, two equivalent ethyl groups attached to one or two nitrogen atoms, and two downfield protons (8.4 ppm), ...

1983-04-12

255

Tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films  

International Nuclear Information System (INIS)

A highly sensitive and stable tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)_3 "2"+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)_3 "2"+ immobilized in the ECL sensor by adsorption of Ru(bpy)_3 "2"+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on ...

2006-04-13

256

Tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films  

Energy Technology Data Exchange (ETDEWEB)

A highly sensitive and stable tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy){sub 3} {sup 2+}) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy){sub 3} {sup 2+} immobilized in the ECL sensor by adsorption of Ru(bpy){sub 3} {sup 2+} onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL ...

2006-04-13

257

Strain-gage for mining instruments  

Energy Technology Data Exchange (ETDEWEB)

The proposed device incorporates an axle which has a roller bearing support mounted upon it. This support uses a cylindrical sleeve that comes in contact with the housing, the sensors, and the bearing support component. Metering accuracy is improved by placing roller bearing supports into grooves running through the protruding center sections of the sensor elements. These roller bearing supports interface with the cylindrical sleeve.

1982-01-01

258

Signal processing methods for MFE plasma diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The application of various signal processing methods to extract energy storage information from plasma diamagnetism sensors occurring during physics experiments on the Tandom Mirror Experiment-Upgrade (TMX-U) is discussed. We show how these processing techniques can be used to decrease the uncertainty in the corresponding sensor measurements. The algorithms suggested are implemented using SIG, an interactive signal processing package developed at LLNL.

1985-02-01

259

Piezoelectric biosensor with a ladder polymer substrate coating  

Energy Technology Data Exchange (ETDEWEB)

A piezoelectric biosensor substrate useful for immobilizing biomolecules in an oriented manner on the surface of a piezoelectric sensor has a ladder polymer of polyacrylonitrile. To make the substrate, a solution of an organic polymer, preferably polyacrylonitrile, is applied to the surface of a piezoelectric sensor. The organic polymer is modifying by heating the polymer in a controlled fashion in air such that a ladder polymer is produced which, in turn, forms the attachment point for the biomolecules comprising the piezoelectric biosensor. 3 figs.

1998-09-29

260

Optical Fiber Sensors from Laboratory to Field Trials: Applications and Trends at CEA LIST  

British Library Electronic Table of Contents (United Kingdom)

Fiber optic metrology developed at the CEA LIST laboratories involves fiber Bragg grating sensors, distributed Brillouin optical time domain reflectometry and optically stimulated luminescence dosimetry. Recent activities in optical fiber sensing are reviewed from laboratory experiments to field trials.

2009-01-01

261

Nanoparticle-assisted chemiluminescence and its applications in analytical chemistry  

British Library Electronic Table of Contents (United Kingdom)

This comprehensive, critical review summarizes the use of nanoparticles in enhanced and amplified chemiluminescence detection, illustrated by different reaction strategies, electrogenerated chemiluminescence sensors, immunoassay or hybridization labels and electrogenerated chemiluminescence immunoassay or hybridization sensors. We discuss the analytical applications on the basis of validity, range and sensitivity, and draw some useful conclusions about the most sensitive approach in each type of application.

2010-01-01

262

Mobile and Marine Robotics  

Science.gov (United States)

University research group with research areas: * Land based and submersible autonomous robots, (UUVs: AUVs and ROVs); * Controllers, electronics, sensor design and fusion, motion control; * Guidance and navigation of underwater vehicles; * AI, neural networks, fuzzy logic, subsumption control, behaviour based control; * Optical fibre and ultrasonic sensors for proximal object detection; * Robot arm control, visual servoing; * Imaging sonar applications; * Simulator development: UUV simulator; imaging sonar simulator; Aircraft/flight simulator.

2007-07-01

263

HORIZON SENSING (PROPOSAL NO.51)  

Energy Technology Data Exchange (ETDEWEB)

Real-time horizon sensing on continuous mining machines is becoming an industry tool. Installation and testing of production-grade Horizon Sensor (HS) systems continued this quarter at Monterey Coal Company (ExxonMobil), Mountain Coal Company West Elk Mine (Arch), and Ohio Valley Coal Company (OVC). Monitoring of system function, user experience, and mining benefits is ongoing. All horizon sensor components have finished MSHA (U.S.) and IEC (International) certification.

2003-07-01

264

Fibre optic grating sensors for biofuels  

Science.gov (United States)

Biofuels will have more intense impact on the energetic grid of the planet, because known fossil fuels reserves are being exhausted. The biofuel production relies on the transformation process of some organic material in the desired hydrocarbon product. Because of the natural characteristics of the related processes, fibre optic sensors appear to be adequate candidates to be used.

2010-09-01

265

Airborne hyperspectral data for the assessment of open cast lignite mining impacts in central Germany  

Energy Technology Data Exchange (ETDEWEB)

The application of airborne sensors for providing environmental assessment and monitoring of a test site in an open cast mining area that is part of a lignite deposit in central Germany is described. Hyperspectral remote sensing data from three different sensors were tested. The hyperspectral scanner data was suitable for classification of different sediments and vegetation types and the water chemistry of residual mining lakes. Summary form only. 1 tab.

1999-07-01

266

AERONAUTICAL ENGINEERING - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Topics addressed include future trends in IR sensors, IR observer performance modeling ... steer a sensor platform with a thermal camera or an air-to-air missile system. .... Skyship and Sentinel series airships. It also outlines the current .... A layout schematic of the UPS is given. AIAA. A93-55494 ...

268

Design of a magnetic braking system  

International Nuclear Information System (INIS)

A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted magnetic flux is within ...

2006-09-01

269

Selection study of self actuated shutdown system for a large scale FBR  

International Nuclear Information System (INIS)

The Self Actuated Shutdown System (SASS) is now under development for use in a large scale FBR, in order to establish the passive shutdown capability against the postulated ATWS events, i.e. ULOF, UTOP and ULOHS. The function of SASS makes use of the safety characteristics of a liquid metal cooled FBRs such as a large subcooling and low pressure system. The insertion of the control rods insertion is assured even in the most conservative seismic design condition by employing articulate rods and the SASS will be installed into the detaching mechanism employing a curie point the magnet alloy. ULOF analysis of the present FBR shows that coolant boiling inception is prevented if a control rod of the SASS is detached at the uppermost temperature of 680degC for the Curie point magnet, and after the reactor shutdown the coolant temperature is kept below 600degC by the pony motor flow. Therefore the SASS will establish passive shutdown capability ...

1995-04-23

270

Preliminary investigation of the magnetostratigraphy of the Ringold Formation  

International Nuclear Information System (INIS)

The Ringold Formation consists of lacustrine and fluvial deposits overlying the Columbia River Basalt. The Ringold Formation, because of its thickness, extent, and age, is an excellent unit in which to detect and possibly data the deformation that has occurred since deposition of the basalt. One objective of this study was to investigate the paleomagnetism of the upper Ringold unit exposed at one location in the White Bluffs in enough detail to resolve, with reasonable confidence, the magnetostratigraphy of the rock units sampled. The other objective was to evaluate, in a preliminary manner, the paleomagnetic favorability and magnetostratigraphy of the subsurface Ringold Formation in the Pasco Basin and at selected exposures outside the Pasco Basin. The scope of this study was the collection of 300 paleomagnetic samples, their measurement, and analysis. Samples were collected from the White Bluffs, from core recovered from six drill holes on the Hanford Site, and from two surface ...

271

Hilar cholangiocarcinoma: MR correlation with surgical and histological findings  

International Nuclear Information System (INIS)

Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the left main branch of ...

2010-10-01

272

Preparation, characterization and electrical properties of SnO{sub 2} based liquid petroleum gas sensor  

Energy Technology Data Exchange (ETDEWEB)

The present investigation deals with the fabrication of liquid petroleum gas (LPG) sensor based on semiconducting oxide SnO{sub 2}. The gas sensor elements have been prepared by conventional solid state route. Addition of noble metal sensitizer, palladium and grain growth inhibitor, aluminum silicate to the base material SnO{sub 2}, not only improved the sensitivity towards LPG but also the selectivity in the presence of CO and CH{sub 4} gases. Out of various sensor compositions, SnO{sub 2}:Al{sub 2}Si{sub 2}O{sub 7} (35 wt.%):Pd (1.5 wt.%) sintered at 800 C for 5 h has shown high sensitivity (0.97) towards LPG at an operating temperature of 350 C. Different characterization techniques have been employed, such as differential thermal analysis (DTA), surface area analyzer, X-ray diffraction (XRD), to study the formation of SnO{sub 2}, surface area and crystallite size, respectively. The results suggested the possibility of ...

1999-03-25

273

Development and application of bio-sensor. Production of ammonia sensor  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this study are to make a biosensor on a trial basis which can instantaneously measure the nitrogen in wastewater, and to develop a wastewater treatment system which is capable of on-line measurement and controlling. The system provides easier operational control relating to such a high efficient treatment as the removal of nitrogen content in wastewater, serving as a solution to the eutrophication problem. It can be applied also to the analysis of fertilizer components for agriculture. Ammonia oxidizing bacteria were immobilized with cellulose acetate film, which is mounted on a diaphragm type oxygen electrode to make a sensor, and its responsibility was studied. The gradient is slow in high concentration but sharp in low concentration, and it seems possible to use it for the measurement for less than 20 ppm nitrogen concentration. The dependence of the sensor including electrodes and activity of bacteria on temperature is ...

1989-08-01

274

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

275

Magnetic fluctuation measurement in Sino United Spherical Tokamak plasma  

International Nuclear Information System (INIS)

To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)

2007-07-01

276

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...

1999-04-01

277

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

278

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

279

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated ...

1999-10-01

280

Magnetic properties of materials  

Energy Technology Data Exchange (ETDEWEB)

A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)

2000-08-15

281

Magnetic flocculation and filtration  

Energy Technology Data Exchange (ETDEWEB)

A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.

1996-10-01

282

A REAL-TIME COAL CONTENT/ORE GRADE (C2OC) SENSOR  

Energy Technology Data Exchange (ETDEWEB)

This is the final report of a three year DOE funded project titled ''A real-time coal content/ore grade (C{sub 2}OG) sensor''. The sensor, which is based on hyperspectral imaging technology, was designed to give a machine vision assay of ore or coal. Sensors were designed and built at Resonon, Inc., and then deployed at the Stillwater Mining Company core room in southcentral Montana for analyzing platinum/palladium ore and at the Montana Tech Spectroscopy Lab for analyzing coal and other materials. The Stillwater sensor imaged 91' of core and analyzed this data for surface sulfides which are considered to be pathfinder minerals for platinum/palladium at this mine. Our results indicate that the sensor could deliver a relative ore grade provided tool markings and iron oxidation were kept to a minimum. Coal, talc, and titanium sponge samples ...

2005-04-01

283

Use of a point-of-care beta-hydroxybutyrate sensor for detection of ketonemia in dogs.  

Science.gov (United States)

The urine test strip is the most common test used to detect ketones in veterinary patients, but it can underestimate the degree of ketonuria and hence, ketonemia. Additionally, adequate urine samples for analysis may be difficult to obtain from dehydrated animals. The standard method used to detect and monitor ketonemia in human medicine is measurement of serum or whole blood beta-hydroxybutyrate (?HOB). A point-of-care (POC) analyzer has been validated for this purpose in humans. This study compared the accuracy of the POC device to an enzymatic reaction laboratory method for measurement of ?HOB in dogs. Although the POC sensor tended to overestimate ?HOB concentrations, there was good correlation (R(2) = 0.96) and good agreement between the 2 methods with a bias +/- precision of 0.0860 +/- 0.3410 mmol/L ?HOB. The POC ?HOB sensor can be useful for assessing ketonemia in dogs. PMID:21119867

2010-09-01

284

Tris(2,2prime-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Platinized Carbon Nanotube-Zirconia-Nafion Composite Films  

British Library Electronic Table of Contents (United Kingdom)

Mesoporous films of platinized carbon nanotube-zirconia-Nafion composite have been used for the immobilization of tris(2,2prime-bipyridyl)ruthenium (II) (Ru(bpy)32+) on an electrode surface to yield a solid-state electrogenerated chemiluminescence (ECL) sensor. The composite films of Pt-CNT-zirconia-Nafion exhibit much larger pore diameter (3.55 nm) than that of Nafion (2.82 nm) and thus leading to much larger ECL response for tripropylamine (TPA) because of the fast diffusion of the analyte within the films. Due to the conducting and electrocatalytic features of CNTs and Pt nanoparticles, their incorporation into the zirconia-Nafion composite films resulted in the decreased electron transfer resistance within the films. The present ECL sensor based on the Pt-CNT-zirconia-Nafion gave a lin...

2010-01-01

285

Significance of microstructure for a MOCVD-grown YSZ thin film gas sensor  

Energy Technology Data Exchange (ETDEWEB)

The authors report the fabrication and characterization of a low temperature (200--400 C) thin film gas sensor constructed from a MOCVD-grown yttria-stabilized zirconia (YSZ) layer sandwiched between two platinum thin film electrodes. A reproducible gas-sensing response is produced by applying a cyclic voltage which generates voltammograms with gas-specific current peaks and shapes. Growth conditions are optimized for preparing YSZ films having dense microstructures, low leakage currents, and maximum ion conductivities. In particular, the effect of growth temperature on film morphology and texture is discussed and related to the electrical and gas-sensing properties of the thin film sensor device.

1996-11-01

286

On the performance of surface plasmon resonance based fibre optic sensor with different bimetallic nanoparticle alloy combinations  

Energy Technology Data Exchange (ETDEWEB)

In this work, we have investigated the capability of different bimetallic nanoparticle alloy combinations to be used in fibre optic sensors based on the technique of surface plasmon resonance. The metals considered for this analysis are silver, gold, copper and aluminium. The performance of the sensor with different bimetallic nanoparticle alloy combinations is evaluated and compared numerically. The performance is analysed in terms of three parameters: sensitivity, signal-to-noise ratio (SNR) and operating range for the sensing layer refractive index values. On the basis of the comparison and some logistic criteria, the best possible bimetallic alloy combinations along with a requisite alloy composition ratio are predicted. The bimetallic nanoparticle alloy combination is capable of simultaneously providing larger values of sensitivity, SNR and operating range, which is not possible with any single metallic nanoparticle layer.

2008-03-07

287

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

Energy Technology Data Exchange (ETDEWEB)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy){sub 3}{sup 2+} and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy){sub 3}{sup 2+}-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy){sub 3}{sup 2+} could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-09-20

288

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

International Nuclear Information System (INIS)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy)_3"2"+ and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy)_3"2"+-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy)_3"2"+ could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-09-20

289

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

British Library Electronic Table of Contents (United Kingdom)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy)32+ and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy)32+-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy)32+ could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-01-01

290

Layer Oriented Wavefront sensor for MAD on Sky operations  

CERN Document Server

The Multiconjugate Adaptive optics Demonstrator (MAD) has successfully demonstrated on sky both Star Oriented (SO) and Layer Oriented (LO) multiconjugate adaptive optics techniques. While SO has been realized using 3 Shack-Hartmann wavefront sensors (WFS), we designed a multi-pyramid WFS for the LO. The MAD bench accommodates both WFSs and a selecting mirror allows choosing which sensor to use. In the LO approach up to 8 pyramids can be placed on as many reference stars and their light is co-added optically on two different CCDs conjugated at ground and to an high layer. In this paper we discuss LO commissioning phase and on sky operations.

2009-01-01

291

Evaluation of soil moisture derived from passive microwave remote sensing over agricultural sites in Canada using ground-based soil moisture monitoring networks  

British Library Electronic Table of Contents (United Kingdom)

Passive microwave soil moisture datasets can be used as an input to provide an integrated assessment of climate variability as it relates to agricultural production. The objective of this research was to examine three passive microwave derived soil moisture datasets over multiple growing seasons in contrasting Canadian agricultural environments. Absolute and relative soil moisture was evaluated from two globally available datasets from the Advanced Microwave Scanning Radiometer for EOS (AMSR-E) sensor using different retrieval algorithms, as well as relative soil wetness at a weekly scale from the Special Sensor Microwave/Imager (SSM/I) sensor. At a daily scale, the Land Parameter Retrieval Model (LPRM) provides a better estimate of surface soil moisture conditions than the National Snow a...

2010-01-01

292

Electrogenerated chemiluminescence sensor for itopride with Ru(bpy)32+-doped silica nanoparticles/chitosan composite films modified electrode  

British Library Electronic Table of Contents (United Kingdom)

A electrogenerated chemiluminescence (ECL) sensor for itopride was developed based on tris(2,2-bipyridyl)ruthenium(II) (Ru(bpy)32+)-doped silica (RuDS) nanoparticles/biopolymer chitosan composites membrane modified glassy carbon electrode (GCE). The RuDS nanoparticles (52+-5nm) were prepared by a modified Stber synthesis method and were characterized by electrochemical, fluorometric and transmission electron microscopy technology. The Ru(bpy)32+ encapsulation interior of the silica nanoparticle maintains its electrochemical activities and also reduces Ru(bpy)32+ leaching from the silica matrix when immersed in water due to the electrostatic interaction. The ECL analytical performances of this ECL sensor for itopride based on its enhancement ECL emission of Ru(bpy)32+ were investigated in d...

2008-01-01

293

Design and performance analysis of MAC schemes for Wireless Sensor Networks Powered by Ambient Energy Harvesting  

British Library Electronic Table of Contents (United Kingdom)

Energy consumption is a perennial issue in the design of wireless sensor networks (WSNs) which typically rely on portable sources like batteries for power. Recent advances in ambient energy harvesting technology have made it a potential and promising alternative source of energy for powering WSNs. By using energy harvesters with supercapacitors, WSNs are able to operate perpetually until hardware failure and in places where batteries are hard or impossible to replace. In this paper, we study the performance of different medium access control (MAC) schemes based on CSMA and polling techniques for WSNs which are solely powered by ambient energy harvesting using energy harvesters. We base the study on (i) network throughput (S), which is the rate of sensor data received by the sink, (ii) fair...

2011-01-01

294

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

295

Calorimetric sensors for energy deposition measurements  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.

1998-12-31

296

Autonomous multi-sensor micro-system for measurement of ocean water salinity  

British Library Electronic Table of Contents (United Kingdom)

This paper describes the design, fabrication and application of a micro-fabricated salinity sensor system. The theoretical electrochemical behaviour is described using electrical equivalent diagrams and simple scaling properties are investigated analytically and numerically using finite element method (FEM). The chip design and fabrication is described and measurement results of two different electrode designs are presented. The 4mm Formula Not Shown 4mm multi-sensor allows for salinity determination with an accuracy of Formula Not Shown 0.5psu through determination of the electrical conductivity, temperature and pressure with accuracies of Formula Not Shown 0.6mS, Formula Not Shown 0.065 Formula Not Shown C and Formula Not Shown 0.05bar, respectively.

2008-01-01

297

Application of Vertically Integrated Electronics to Intelligent Trackers  

CERN Document Server

At Super-LHC luminosity it is expected that the standard suite of L1 triggers for CMS will saturate. Information from the tracker will be needed to reduce trigger rates to satisfy the L1 bandwidth. Tracking trigger modules which correlate information from closely-spaced sensor layers to form an on-detector momentum filter are being developed by several groups. We report on a trigger module design which utilizes three dimensional IC technology to incorporate chips which are connected both to the top and bottom sensor, providing the ability to filter information locally. A demonstration chip, the VICTR, has been submitted to the Chartered/Tezzaron two-tier 3D run coordinated by Fermilab. We report on the 3D design concept, the status of the VICTR chip and associated sensor integration utilizing oxide bonding.

2010-01-01

298

A program for passively tracking a target using an array of sensors  

Energy Technology Data Exchange (ETDEWEB)

The problem of passively tracking a moving signal source has importance in a variety of applications such as radar, sonar, seismology, and radio astronomy. In many applications, only limited information is available about the signal source. It will be assumed here that only the signals which are detected by the sensors and the velocity of the source signal are known. The objective of this document is to present a program which passively tracks a target using an array of sensors. This program is available in MATLAB, version 3.5. The algorithm which is implemented consists of three main parts: time delay estimation, passive localization, and data post processing. Each of these parts are discussed, and the mathematical foundation for their solution given. Following, this the organization of the program is presented, and an example of its usage is given.

1993-01-01

299

A novel electrogenerated chemiluminescence sensor for pyrogallol with core-shell luminol-doped silica nanoparticles modified electrode by the self-assembled technique  

British Library Electronic Table of Contents (United Kingdom)

The core-shell luminol-doped SiO2 nanoparticles were synthesized and immobilized on the surface of chitosan film coating graphite electrode by the self-assembled technique. Then, a novel electrogenerated chemiluminescence (ECL) sensor for pyrogallol was developed based on its ECL enhancing effect for the core-shell luminol-doped silica nanoparticles. The ECL analytical performances and the sensing mechanism of this ECL sensor for pyrogallol were investigated in detail. The corresponding results showed that: compared with the conventional ECL reaction procedures by luminol ECL reaction system, the electrochemical (EC) reaction of pyrogallol and its subsequent chemiluminescence (CL) reaction occurred in the different spatial region whilst offering a high efficiency to couple the EC with the ...

2006-01-01

300

A mobile remote sensing laboratory for water vapor, trace gas, aerosol, and wind speed measurements  

Energy Technology Data Exchange (ETDEWEB)

The Lawrence Livermore National Laboratory has developed a mobile field laboratory for remote measurement of atmospheric processes and observables that are important in global climate change, dispersal of hazardous materials, and atmospheric pollution. Specific observables of interest are water vapor, trace gases, aerosol size and density, wind, and temperature. The goal is to study atmospheric processes continuously for extended periods in remote field locations. This laboratory has just reached field ready status with sensors for aerosol and trace gas measurement based on established techniques. A development program is underway to enhance the sensor suite with several new techniques and instruments that are expected to significantly extend the state of the art in remote trace gas analysis. The new sensors will be incorporated into the lab during the next two years.

1993-03-19

301

A MAC protocol for cognitive wireless sensor body area networking  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this paper, a Cognitive Radio Based Medium Access Control (CR-MAC) protocol for Wireless Sensor Body Area Networks (WSBAN) that utilizes cognitive radio transmission is proposed. In this proposal, the sensor nodes are classified into nodes of life-critical health information and nodes of non-critical health information. The CR-MAC protocol prioritizes the critical packets access to the transmission medium by transmitting them with higher power while transmitting lower priority packets using lower transmission power. At the receiver, a higher priority packet experiences collision only when there are more than one critical packet transmission at the same transmission slot while non critical packets experience collision when there are more than one transmission at the same transmi...

2010-01-01

302

Stent placement under real-time MR control: first experience in an animal model; Stentplazierung unter Echtzeit-MR-Kontrolle: erste tierexperimentalle Erfahrungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were ...

1998-12-01

303

The effective longitudinal dielectric constant for plasmas in inhomogeneous magnetic fields  

Scientific Electronic Library Online (English)

Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.

2004-09-01

304

Magnetic mirror fusion systems: Characteristics and distinctive features  

Energy Technology Data Exchange (ETDEWEB)

A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.

1987-08-10

305

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

306

Magnetic excitations studied with time-of-flight spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.

1996-11-01

307

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

308

Active magnetic regenerator  

Energy Technology Data Exchange (ETDEWEB)

The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.

1982-01-01

309

Nanocrystalline permanent magnets with enhanced properties  

International Nuclear Information System (INIS)

Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

2001-09-23

310

Untitled - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...

311

Symptoms of the musculoskeletal system and exposure to magnetic fields in an aluminium plant.  

UK PubMed Central (United Kingdom)

OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available

1995-08-01

312

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.

1985-08-01

313

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be ...

2009-10-19

314

Possible observation of the coexistence of superconductivity and long-range magnetic order in NdRh_4B_4  

International Nuclear Information System (INIS)

The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).

1979-01-01

315

PLASMA JET WELDING, COATING, AND CUTTING: AN ...  

Science.gov (United States)

... 31. New electric forming methods offer potentials for light metals; magnetic forming and plasma forming. ... 3, 25 Magnetic Forming ..... ...

1963-02-01

316

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

Energy Technology Data Exchange (ETDEWEB)

Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-15

317

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

International Nuclear Information System (INIS)

Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...

2008-07-01

318

Mechanism of viscosity effect on magnetic island rotation  

Energy Technology Data Exchange (ETDEWEB)

It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)

2000-04-01

319

Magnetic Properties of Ni Nanoparticles Embedded in ...  

Science.gov (United States)

... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...

2011-05-14

320

Localization of small magnets against a noisy background  

Science.gov (United States)

Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.

2001-05-01

321

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

322

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...

2005-02-01

323
324

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI ...

2009-05-15

325

Evaluation of Commercial Magnetic Descalers.  

Science.gov (United States)

With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...

1984-01-01

326

Develop Magnetic Coil Design and Manufacturing Capability.  

Science.gov (United States)

... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...

1974-11-01

328

CONTRACT: NAS 8-11811 DESIGN, DEVELOPMENT, MANUFACTURE, AND ...  

Science.gov (United States)

has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magnetic coil is placed over a thin aluminum ...

329

Application of the grazing angle polarized neutron reflectometry to study the magnetism in thin films and stratified media  

Energy Technology Data Exchange (ETDEWEB)

From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...

1992-12-01

330

Anisotropic forming of magnetic powders mixed with ultraviolet resin; Shigaisen koka jushi wo mochiita jisei funmatsu no haiko seikei  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...

1999-01-15

331

An Advance in Superconducting Magnet Technology Opens the Door...  

Science.gov (United States)

magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...

2011-08-20

332

hysics Facility - NASA  

Science.gov (United States)

vehicles including the H2-A rocket and the space shuttle. .... The vacuum can's main function is to provide a high vacuum so that the science experiment and its sensors ... EMI-shielded power conversion from the incoming ISS power supply. 4. ...

333

ch3 - NASA History Office  

Science.gov (United States)

Incoming solar energy had to be assimilated to sustain it. .... Roll stability was achieved with an Earth sensor mounted on the directional antenna. .... Once more a rocket becomes the means of producing a vector change in velocity. ...

334

Urethral sleeve sensor: a non-withdrawal method to measure maximum urethral pressure  

UK PubMed Central (United Kingdom)

Introduction and hypothesisThis study seeks to evaluate axial variation, comparisons with current technology, performance during dynamic conditions, and patient tolerability of the...Full Text Available

2010-06-01

335

The selection and definition of targeted work-related conditions for surveillance under SENSOR.  

UK PubMed Central (United Kingdom)

Lists of reportable conditions and case definitions are important tools for epidemiologic surveillance. As part of an initiative to encourage occupational disease surveillance systems linked to intervention...Full Text Available

1989-12-01

336

The Goddard Library - Goddard Projects Directory - NASA  

Science.gov (United States)

Oct 2, 2007 ... The Payload combines some of the most sensitive particle sensors .... provide state-of-the-art measurements of incoming x-ray, ultraviolet, .... It will be launched into a low-Earth orbit on a Delta 7320 rocket in September 2004. ...

337

The Cytokinin Receptors of Arabidopsis Are Located Mainly to the Endoplasmic Reticulum1[W][OA]  

UK PubMed Central (United Kingdom)

The plant hormone cytokinin is perceived by membrane-located sensor histidine kinases. Arabidopsis (Arabidopsis thaliana) possesses three cytokinin receptors: ARABIDOPSIS HISTIDINE...Full Text Available

2011-08-01

338

The Atmospheric Trace ... - NASA Langley Science Directorate  

Science.gov (United States)

Trace gas molecules absorb specific wavelengths of incoming solar ... These data(with information collected from similar experiments carried on balloons, rockets, ... The ATMOS sensor instrumentis a state-of-the-art version of a 19th century ...

339

Tarantula Huwentoxin-IV Inhibits Neuronal Sodium Channels by Binding to Receptor Site 4 and Trapping the Domain II Voltage Sensor in the Closed Configuration*S?  

UK PubMed Central (United Kingdom)

Peptide toxins with high affinity, divergent pharmacological functions, and isoform-specific selectivity are powerful tools for investigating the structure-function relationships of voltage-gated...Full Text Available

2008-10-03

340

THEMIS-D - SPASE Resource Description  

Science.gov (United States)

Feb 23, 2011 ... THEMIS-D: The Solid State Telescope (SST) measures the incoming ... Each single sensor covers an angle of 36 degrees. .... The five small satellites were launched together on a Delta II rocket and they carry identical ...

341

Spacecraft and Instruments - NASA  

Science.gov (United States)

Aerosol Polarimetry Sensor (APS) + Continuous along-track scanning ... side of the spacecraft and faces outward, measures the intensity of incoming solar ... on a larger rocket, and faced slightly different conditions in spaceinto Glory wasn't ...

342

Site Error There's a problem with ... - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Bending moments recorded by sensors on the aluminum tube. ... the escape rocket motor, tests also were made with the escape tower and rocket .... Incoming photographic data will be electronically converted and processed ...

343

Serotype- and strain- dependent contribution of the sensor kinase CovS of the CovRS two-component system to Streptococcus pyogenes pathogenesis  

UK PubMed Central (United Kingdom)

BackgroundThe Streptococcus pyogenes (group A streptococci, GAS) two-component signal transduction system CovRS has been described to be important for pathogenesis...Full Text Available

344

Sandia microelectronics development  

Energy Technology Data Exchange (ETDEWEB)

An overview of the operations of Sandia`s Microelectronics Development Lab (MDL) is to develop radiation hardened IC, but techniques used for IC processing have been applied to a variety of related technologies such as micromechanics, smart sensors, and packaging.

1997-02-01

345

SPASE Resource Description - the VMO - NASA  

Science.gov (United States)

THEMIS-A: The Solid State Telescope (SST) measures the incoming intensity ... units (heads), each SST unit has two pairs of opposing ion and electron sensors. .... The five small satellites were launched together on a Delta II rocket and they ...

346

Remote environmental monitoring at No. 26 Colliery  

Energy Technology Data Exchange (ETDEWEB)

The author describes the layout of the environmental monitoring scheme at Devco's No. 26 Colliery in Canada, which includes wall face ventilation, fan performance, and methane drainage monitoring. He gives details of the sensors, outstations, and the surface control room.

1982-03-01

347

Rapid Responding Palladium-Silver Surface Modified Microsensor for Hydrogen  

Science.gov (United States)

Most palladium thin film based hydrogen gas sensors have response and recovery times that are too long to make them useful in vehicular and stationary gas leak detection applications. In contrast, a palladium-silver thin film based microcantilever (MC) hydrogen gas microsensor is reported herein with near ideal response characteristics for use in these hydrogen economy related applications. Specifically, 3-10 second response and recovery times have been measured for these sensors in contrast to previous sensor response measurements of several to tens of minutes using Pd thin film and MC based sensing techniques. The much reduced response times observed in the present study are attributed to a wet chemical Pd-Ag thin film deposition technique and a gas conditioning protocol that produces a highly nanostructured, porous film that rapidly adsorbs and desorbs H2, allowing rapid equilibration with the H2 concentration in the ...

2010-01-01

348

Proposal to negotiate an amendment to an existing contract for the supply of thick 6 inch silicon micro-strip sensors for the CMS tracker  

CERN Document Server

This document concerns the proposal to negotiate an amendment to an existing contract for the supply of thick 6 inch silicon micro-strip sensors for the CMS tracker. For the reasons explained in this document, the Finance Committee is invited to approve an amendment to an existing contract with HAMAMATSU PHOTONICS (CH) for the supply of 7 000 thick 6 inch silicon micro-strip sensors for the CMS tracker, for an amount of 3 248 000 euros (5 131 840 Swiss francs), not subject to revision, with an option for up to 11 000 additional sensors, for a maximum amount of 4 708 000 euros (7 438 640 Swiss francs), not subject to revision, bringing the total maximum amount of the amendment to 7 956 000 euros (12 570 480 Swiss francs) not subject to revision. This total maximum amount will be added to the initial contract amount of 415 835 000 Japanese yen (4 879 824 Swiss francs), not subject to revision. The amounts in Swiss francs have ...

2004-01-01

349

Programs Automate Complex Operations Monitoring - NASA  

Science.gov (United States)

Mar 2, 2011 ... CCT's software is capable of simultaneously handling incoming ... has been using CCTK to automate its remote control rocket cryogenic fueling systems. ... seismic, infrared, and proximity sensor data with auto-tracking ...

350

PAS Domain Residues Involved in Signal Transduction by the Aer Redox Sensor of Escherichia coli  

UK PubMed Central (United Kingdom)

SummaryPAS domains sense oxygen, redox potential and light, and are implicated in behavior, circadian rhythmicity, development and metabolic regulation. Although PAS domains are...Full Text Available

2000-05-01

352

Observatory: Cluster FM5 (Rumba) - SPASE Resource Description  

Science.gov (United States)

Feb 7, 2011 ... The potentials of the spherical sensor and nearby conductors are controlled ... Incoming data are continuously monitored by algorithms in the software ... together with FM8 (Tango) by a Soyuz-Fregat rocket from Baikonur. ...

353

NASA 2005 STTR Phase 1 Solicitation - NASA's SBIR & STTR Programs  

Science.gov (United States)

Advanced aerospace vehicles and system components tend to be slim and elastic, ...... In the manufacturing sector, semiconductor manufacturing requires ... The energy generation and storage for modern-day sensor networks, ...... Current NASA roadmaps point towards development of new hydrocarbon fueled engines. ...

354

Membrane protein biosensing with plasmonic nanopore arrays and pore-spanning lipid membranes  

UK PubMed Central (United Kingdom)

Integration of solid-state biosensors and lipid bilayer membranes is important for membrane protein research and drug discovery. In these sensors, it is critical that the solid-state sensing...Full Text Available

2010-01-01

355

Meet the NASA Scientists and Engineers Andrea ... - Aura - NASA  

Science.gov (United States)

Equipped with terahertz sensors, the Aura mission will see far more ... We introduce you to a few amazing individuals, all sharing the dubious title of rocket scientist . And a ..... similar thing happens with incoming light. Astronomers call it the ...

356

March 2007 - Discovery Program - NASA  

Science.gov (United States)

The NS together with a gamma ray sensor make up the Gamma- Ray and ... A simplified view of the interactions between incoming cosmic rays and the .... held in Huntsville, Alabama, at the U.S. Space and Rocket Center on January 2830. ...

357

METEOROLOGICAL SATELLITES - NASA's History Office  

Science.gov (United States)

Study of cloud pictures taken from rockets, such as figure 1, indicates that it is .... One might visualize a "Satellite Weather Data Center" where incoming data would ... about 300 miles; satellite packaging, containing the sensors, storage, power, ...

358

Involvement of AMP-activated-protein-kinase (AMPK) in neuronal amyloidogenesis  

UK PubMed Central (United Kingdom)

AMP-activated-protein-kinase (AMPK) is a key sensor and regulator of cellular and whole-body energy metabolism and plays a key role in regulation of lipid metabolism. Since lipid metabolism...Full Text Available

2010-09-03

359

International Space Station Overview - NASA  

Science.gov (United States)

(accumulates & stores brine for disposal). Separator. (separates water from purge gases). ? Purge pump periodically vent ... Reactor Health. Sensor. ( verifies reactor is operating w/n limits) ... Waste and Hygiene Compartment ...

360

Human Performance Studies for Control of Multiple Remote ...  

Science.gov (United States)

... 1 8.53 1.5448 2 12.45 2.1944 3 16.59 2.5224 Sensor Mobility fixed 8.92 1.9312 mobile 12.15 2.3625 Display Configuration conv. 10.92 1.7981 ...

1994-07-01

361

Geophysical Remote Sensing - The Remote Sensing Tutorial - NASA  

Science.gov (United States)

It was thus actually the fourth stage of the rocket assembly. ... package, and several temperature sensors - was mounted in the cross-lattice frame. ... Earth's geomagnetic field and incoming charged particles from the Sun and extra-solar space. ...

362

Epilogue - GES DISC - NASA  

Science.gov (United States)

Sep 9, 2009... a French Ariane rocket successfully launched a new Earth-observing satellite ... The payload is a pair of identical sensors known as "high-resolution ... the resulting image) are activated simultaneously by incoming radiation; ...

363

Discovery Dispatch - Discovery Program - NASA  

Science.gov (United States)

funded these sensors as the first Discovery Mission of. Opportunity, part of the ... aboard a Russian Soyuz rocket. .... the Swedes on other projects, mainly sounding rocket projects. ..... incoming applications for the Fellowship Program, fielding ...

364

Dimeric subunit stoichiometry of the human voltage-dependent proton channel Hv1  

UK PubMed Central (United Kingdom)

In voltage-gated Na+, K+, and Ca2+ channels, four voltage-sensor domains operate on a central pore domain in response to membrane voltage. In contrast, the voltage-gated...Full Text Available

2008-06-03

365

Development of micro capacitive accelerometer for subsurface microseismic measurement; Micromachining ni yoru chika danseiha kenshutsu no tame no silicon yoryogata kasokudo sensor no seisaku  

Energy Technology Data Exchange (ETDEWEB)

A silicon capacitive accelerometer was fabricated to detect subsurface elastic waves by using micromachining technology. Characteristics required for it call for capability of detecting acceleration with amplitudes from 0.1 to 1 gal and flat amplitude characteristics in frequency bands of 10 Hz to several kHz. For the purpose of measuring transition phenomena, linear phase characteristics in the required bands must be guaranteed, cross sensitivity must be small, and resistance to water, pressure and heat is demanded. Sensitivity of the sensor is determined finally by noise level in a detection circuit. The sensor`s minimum detection capability was 40 mgal in the case of the distance between a weight and an electrode being 3 {mu}m. This specification value is a value realizable by the current micromachining technology. Dimensions for the weight and other members were decided with the natural frequency to make band width 2 kHz set to 4 kHz. ...

1997-05-27

366

Analysis of Energy Consumption for Ad Hoc Wireless Sensor ...  

Science.gov (United States)

Aug 15, 2002 ... In Section II, we describe the routing and transceiver power model used ... In our power model, we assume a certain non-zero minimum level of ...

367

AMP-Activated Protein Kinase: A Stress-Responsive Kinase with Implications for Cardiovascular Disease  

UK PubMed Central (United Kingdom)

AMP-activated protein kinase (AMPK) was initially viewed as energy sensor and activated by increased intracellular concentrations of AMP following nutrient deprivation. Physiological or pathological...Full Text Available

2010-04-01

368

AICAR inhibits adipocyte differentiation in 3T3L1 and restores metabolic alterations in diet-induced obesity mice model  

UK PubMed Central (United Kingdom)

BackgroundObesity is one of the principal causative factors involved in the development of metabolic syndrome. AMP-activated protein kinase (AMPK) is an energy sensor that regulates...Full Text Available

369

A Review on Sensor, Signal, and Information Processing ...  

Science.gov (United States)

... Rep. ISIS-04-504, Institute for Software Integrated Systems (2004). [59] G. Simon, M. Maroti, A. Ledeczi, G. Balogh, B. Kusy, A. Nadas, G. Pap, J ...

2011-05-15

370

5 - NASA Technical Reports Server  

Science.gov (United States)

The mission includes a reflected solar instrument retrieving at-sensor .... incoming solar radiation. This direct aerosol radiative forcing (DARF) ... examining the behavior of geosynchronous rocket bodies and non-stabilized payloads as ...

371

*1-Front Piece - NASA Aqua  

Science.gov (United States)

properties such as effective particle size, thermody- namic phase (water, ice), cloud-top properties ...... Green, R.O., and J.E. Conel, 1995: Movement of ..... vertical hydrometeor profiles from passive micro- wave sensors. IEEE Trans. ...

372

Unified requirements for monitoring of ventilation of drifts in coal and shale mines  

Energy Technology Data Exchange (ETDEWEB)

Ventilation of blind drifts in the Karaganda Basin because of the high release of methane is a very important task. As indicated by measurements in 116 blind drifts, on the average the magnitude of air velocity in the pipelines VPM is in limits of 15-25 m/sec. The DPV-1 sensor encompasses almost the entire range of velocities of air motion. Operation of the DPV-1 sensors at mines of the production association ''Karaganda-ugol''' confirmed their high reliability and convenience for operation.

1982-01-01

373

Scale-dependent errors in the estimation of land-cover proportions. Implications for global land-cover datasets  

Energy Technology Data Exchange (ETDEWEB)

Aggregation of fine-resolution land-cover maps to coarser scales indicates that estimates of the proportions of land-cover types vary as a function of spatial resolution. The magnitude of these proportional errors in a forested area in northern California increase significantly as resolution exceeds a 90-m threshold. These errors could pose difficulties for the use of land-cover products generated from coarse-resolution sensors such as the NOAA-AVHRR and the MODIS sensor planned for the EOS program. The magnitude of the errors appears to be a function of the spatial resolution of the map, the original size of the land-cover classes, and the spatial patterns of the classes.

1994-05-01

374

New coumarin-based sensor molecule for magnesium and calcium ions  

British Library Electronic Table of Contents (United Kingdom)

A new coumarin-based sensor molecule (L1) has been synthesized and this was found to bind calcium and magnesium ions more effectively as compared to other alkali/alkaline earth/lanthanide and certain transition metal ions. A significant enhancement in fluorescence intensity was observed on binding to Ca2+ and Mg2+ ions; while a minor quenching was observed for weakly bound Hg2+, Ni2+, Fe3+, and Co2+ ions. PET process, coupled with the ICT process, is proposed to explain the observed spectral response.

2009-01-01

375

Development of a motion analysis system using acceleration sensors for tennis and its evaluations  

British Library Electronic Table of Contents (United Kingdom)

The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.

2011-01-01

376

A truly commercial product  

International Nuclear Information System (INIS)

In one of the first uses of high Tc superconductors in an end-use product, Lake Shore Cryotronics and a Swiss lab have developed a liquid nitrogen level sensor using a high Tc thin film. The probe is manufactured using a seamless stainless steel tube with an yttrium-based zirconium oxide flame-sprayed on the tube. A plasma-sprayed superconductor compound is deposited on top of that. The probe is coated with a sealant that protects the superconducting film from the atmosphere. This manufacturing method has yielded an extremely durable product. Unaffected by ice formation and related mechanical problems, the superconducting level sensor can be kept in the dewar for long periods of time.

377

Magnetic properties of a SmNiSn single crystal  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the ...

2003-04-01

378

Development of magnetic drive packless valves for commercial purpose  

Energy Technology Data Exchange (ETDEWEB)

A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting ...

1995-09-01

379

Challenges in fabrication of 180deg magnet chamber  

International Nuclear Information System (INIS)

180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector ...

2006-11-01

380

AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab  

Energy Technology Data Exchange (ETDEWEB)

Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar ...

1992-09-01

381

Aurivillius phases of PbBi4Ti4O15 doped with Mn3+ synthesized by molten salt technique: Structure, dielectric, and magnetic properties  

International Nuclear Information System (INIS)

Doping of manganese (Mn3+/Mn4+) into the Aurivillius phase Pb1-xBi4+xTi4-xMnxO15 was carried out using the molten salt technique for various Mn concentrations (x=0, 0.2, 0.4, 0.6, 0.8, and 1). Single phase samples could be obtained in the composition range with x up to 0.6 as confirmed by X-ray and neutron diffraction analysis. Dielectric measurements show a peak at 801, 803, 813 and 850 K for samples with x=0, 0.2, 0.4, and 0.6, respectively, related to the ferroelectric transition temperature (Tc). The main contribution of the in-plane polarization for x?0.2 which was calculated from the atomic positions obtained by the structure analysis is the dipole moment in the Ti(1)O6 layer; however, for x?0.4 the polarization originates from the dipole moment in the Ti(2)O6 layer. Mn doping in the Pb1-xBi4+xTi4-xMnxO15 does not show any long range magnetic ordering. -- Graphical abstract: The dipole moment of TiO6 dependence of x in ...

2011-05-01

382

Optical chemical sensors for atmospheric pollutants based on nano porous materials: application to the formaldehyde and the other carbonyl compounds; Capteurs chimiques a transduction optique de polluants atmospheriques a base de materiaux nanoporeux: application au formaldehyde et autres composes carbonyles  

Energy Technology Data Exchange (ETDEWEB)

Formaldehyde, a well-identified indoor pollutant, was recently classified as carcinogenic. New regulations for the air quality are expected and therefore there is a need for low-cost sensors, sensitive and selective with a fast response time for the detection of formaldehyde at ppb level. In the present work, we had developed a chemical sensor based on nano-porous matrices doped with Fluoral-P and optical methods of detection. The nano-porous matrices, elaborated via the Sol-Gel process, display nano-pores whose cavity is tailored for the trapping of the targeted pollutant. They provide a first selectivity with the discrimination of the pollutants by their size. A second selectivity is obtained with a molecular probe, Fluoral-P, which reacts specifically with formaldehyde leading to the 3,5- di-acetyl-1,4-dihydro-lutidine (DDL). The kinetics of formation of DDL was studied as function of many parameters such as the concentration of Fluoral-P in ...

2006-12-15

383

Change in HER-2/neu Status from Negative to Positive following Treatment in Breast Cancer: A Case Report  

UK PubMed Central (United Kingdom)

IntroductionApproximately 25–30% of breast cancers are assumed to be HER-2/neu positive. It is well known that HER-2/neu-positive cancers after treatment with trastuzumab...Full Text Available

384

Capacity of staphylococci to grow in the presence of ovotransferrin or CrCl3 as a character of potential pathogenicity.  

UK PubMed Central (United Kingdom)

A total of 150 strains of staphylococci, clinically isolated, were tested for sensitivity to ovotransferrin (conalbumin). Among these, all the 50 coagulase-positive, mannitol-positive, and deoxyribonuclease-positive...Full Text Available

1980-05-01

385

Truth Breakers  

British Library Electronic Table of Contents (United Kingdom)

Philosophical semantics requires an ontology that includes negative as well as positive states of affairs as truth-makers and truth-breakers. Theories that try to do without negative states of affairs while interpreting propositional truth as positive correspondence with existent states of affairs are inherently inadequate and incomplete. A semantics and ontology of negative states of affairs can also do justice to positive states of affairs, since the iterated negative state of affairs that a negative state of affairs exists describes a positive state of affairs, but the iterated positive state of affairs that a positive state of affairs exists never describes a negative state of affairs. Negative states of affairs are not only essential to semantics, but to a complete description of the ...

2010-01-01

386

Polyurethane - positioning aids in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders.

1985-06-01

389

The Effect of Static Magnetic Forces on Water Contents and Photosynthetic Pigments in Sweet Basil Ocimum basilicum L. (Lamiaceae)  

International Nuclear Information System (INIS)

Three different magnetic regimes; aerial, surface and buried; each with three different forces, have been used to investigate their effects on the water contents and photosynthetic pigments of sweet basil plants (Ocimum basilicum L.). Two groups of sweet basil seeds, Ocimum basilicum L. have been cultivated, one under normal conditions and the second has been subdivided into three portion (aerial, surface and buried) to examine the effect of different magnetic forces coming from the three directions on the resulted plants. At all directions of magnets, water contents have been significantly affected by the magnetic forces. Chlorophyll A and carotene contents have been affected, as well, according to the three magnetic forces coming from soil surface regime only. Chlorophyll B did not significantly affected by differences magnetic forces in the three regimes, but ...

390

THE APPLICATION OF STEEP PULSE CURRENTS TO THE ...  

Science.gov (United States)

... Title : THE APPLICATION OF STEEP PULSE CURRENTS TO THE ELECTROHYDRAULIC AND MAGNETIC FORMING OF METALS. ...

1966-04-01

397

Recovery Effects of a 180?mT Static Magnetic Field on Bone Mineral Density of Osteoporotic Lumbar Vertebrae in Ovariectomized Rats  

UK PubMed Central (United Kingdom)

The effects of a moderate-intensity static magnetic field (SMF) on osteoporosis of the lumbar vertebrae were studied in ovariectomized rats. A small disc magnet (maximum magnetic flux density 180 mT)...Full Text Available

2011-01-01

398

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

399

Perpendicular magnetic anisotropy of ultrathin FeCo alloy films on Pd(0 0 1) surface: First principles study  

International Nuclear Information System (INIS)

Using the full potential linearized augmented plane wave (FLAPW) method, thickness dependent magnetic anisotropy of ultrathin FeCo alloy films in the range of 1 monolayer (ML) to 5 ML coverage on Pd(0 0 1) surface has been explored. We have found that the FeCo alloy films have close to half metallic state and well-known surface enhancement in thin film magnetism is observed in Fe atom, whereas the Co has rather stable magnetic moment. However, the largest magnetic moment in Fe and Co is found at 1 ML thickness. Interestingly, it has been observed that the interface magnetic moments of Fe and Co are almost the same as those of surface elements. The similar trend exists in orbital magnetic moment. This indicates that the strong hybridization between interface FeCo alloy and Pd gives rise to the large magnetic moment. Theoretically calculated ...

2009-06-01

401

Optimization of soft magnetic properties in Fe-B and Fe-B-Si amorphous alloys obtained by melt spinning method  

International Nuclear Information System (INIS)

In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)

2001-09-23

402

NASA Technical Reports Server - Magnetic forming coil design and ...  

Science.gov (United States)

Site Error There's a problem with your browser or settings. ...

407

Magnetic forming studies  

Science.gov (United States)

Elastodynamic approach to measuring stress-strain relationship of uniaxially stressed wire, and

1967-01-01

409

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

410

Magnetic electronic lenses, quadrupole and octupole for microsystem electron beam techniques  

International Nuclear Information System (INIS)

The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered

2006-09-01

414

Influence of rotation and magnetic field on the minimum mass of a main-sequence star  

Energy Technology Data Exchange (ETDEWEB)

The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.

1980-11-01

431

A STUDY TO DETERMINE THE DEFORMATION ...  

Science.gov (United States)

... crystals and polycrystals. Nevertheless, explosive forming, magnetic forming, etc., are all high-strain-rate processes that ...

1963-04-01

432

A HELICAL MAGNET DESIGN FOR RHIC.  

Energy Technology Data Exchange (ETDEWEB)

Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.

1997-05-12

433

Magnetocaloric and magnetoresistance studies of GdPd{sub 2}Si  

Energy Technology Data Exchange (ETDEWEB)

The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...

2001-01-22

434

Magnetocaloric and magnetoresistance studies of GdPd_2Si  

International Nuclear Information System (INIS)

The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...

2001-01-22

435

Magnetic separation anxiety  

International Nuclear Information System (INIS)

This paper reports that only a few years ago superconducting magnetic separation was viewed as the next major market for superconducting magnets. The first commercial units had been installed, worked flawlessly, and demonstrated real economic viability. The potential market was seen as quite large, and many people believed that superconducting magnetic separation would soon show the same rapid growth that MRI had demonstrated after its initial success. These hopes even prompted IGC, one of the top MRI magnet builders, to form a separate division devoted to magnetic separation. Despite the existence of Magstream, IGC has not been overly active in the market. As a technology that has applications from the clay on the Earth to the soil on the moon, superconducting magnetic separation has yet to become widely used.

1992-01-01

436

Effect of the induced magnetic field on peristaltic flow of a couple stress fluid  

Science.gov (United States)

We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and ...

2008-06-01

437

Phase I Report: DARPA Exoskeleton Program  

Science.gov (United States)

The Defense Advanced Research Projects Agency (DARPA) inaugurated a program addressing research and development for an Exoskeleton for Human Performance Augmentation in FY!2001. A team consisting of Oak Ridge National Laboratory, the prime contractor, AeroVironment, Inc., the Army Research Laboratory, the University of Minnesota, and the Virginia Polytechnic Institute has recently completed an 18-month Phase I effort in support of this DARPA program. The Phase I effort focused on the development and proof-of-concept demonstrations for key enabling technologies, laying the foundation for subsequently building and demonstrating a prototype exoskeleton. The overall approach was driven by the need to optimize energy efficiency while providing a system that augmented the operator in as transparent manner as possible (non-impeding). These needs led to the evolution of two key distinguishing features of this team's approach. The first is the ''no knee ...

2004-01-21

438

On the temperature dependence of the magnetic excitations  

International Nuclear Information System (INIS)

We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# function shows that ...

2005-07-15

439

Theory of zwitterionic molecular-based organic magnets  

British Library Electronic Table of Contents (United Kingdom)

We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.

2011-01-01

440

Occurrence of magnetism in superconductors  

Science.gov (United States)

We discuss how magnetic phenomena affect superconductivity in simple metals, transition metals and alloys thereof, and dilute Rare-Earth alloys. It is shown both qualitatively and quantitatively that superconductors are sensitive probes for studying itinerant spin excitations, local spin excitations associated with nearly magnetic impurities, the effect of the atomic environment on the stability of local magnetic moments, and the nature of the spin order in Rare-Earth alloys. Also, we discuss how magnetic impurities can be used to study the electronic configuration which is responsible for superconductivity in Laves-phase crystals like A-15 compounds and ..beta..-W crystals, for example.

1970-12-14

441

Magnetic response of ultrathin Fe on MgO: A polarized neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.

1994-11-15

442

Magnetic properties of glasses from geothite industrial wastes recycling (FeOOH)  

International Nuclear Information System (INIS)

It has been carried out the magnetic properties determination for high iron oxide content glasses series obtained from a geothite red mud waste from the zinc hydrometallurgy and dolomite and glass cullet as main raw materials. It has been determined the magnetic susceptibility and magnetization values for the glasses here investigated. The results suggest that the magnetic behaviour are depending on the glass chemical composition, so that glasses can be differently classified like ferrimagnetic, ferromagnetic, superparamagnetic and paramagnetic. (Author) 6 refs.

443

Hydromagnetic rotational braking of magnetic stars  

International Nuclear Information System (INIS)

It is suggested that the magnetic Ap stars can be rotationally decelerated to long periods by the braking action of the associated magnetic field on time scales of order 10"7--10"1"0 years depending on whether the star's dipole field is aligned perpendicular or parallel to the rotation axis. Rotation includes a toroidal magnetic field in the plasma surrounding a star, and the accompanying magnetic stresses produce a net torque acting to despin the star. These results indicate that it is not necessary to postulate mass loss or mass accretion for this purely hydromagnetic braking effect.

444

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake corresponding to ...

2003-11-01

445

Thermal and tectonic history of the Ordos Basin, China: Evidence from apatite fission track analysis, vitrinite reflectance, and K-Ar dating  

Energy Technology Data Exchange (ETDEWEB)

Apatite fission track analysis, vitrinite reflectance data, and K-Ar dating of Permian-Carboniferous and Mesozoic core samples have been successfully integrated to reconstruct the thermal and tectonic history of the Ordos basin, China. Apatite fission track ages of Carboniferous-Jurassic sedimentary rocks range between 3 and 137 Ma, and are significantly younger than the stratigraphic ages. Confined fission track lengths demonstrate exclusively mixed length distribution, indicating complex thermal history. The data suggest that the samples must have all experienced higher paleotemperatures in the past. Mean virtinite reflectance values (R{sub o}) of the Triassic rocks range from 0.61 to 1.06%, giving a high coalification gradient of 0.36%/km and suggesting a high paleothermal gradient of 57{degrees}C/km. Permian-Carboniferous rocks have R{sub o} values on the order of 1.0-3.0%, and locally up to 4.0-6.0%. Some high R{sub o} values coincide with positive gravity and ...

1996-07-01

446

Monitoring the effect of chemotherapy in Ewing's sarcoma of bone with MR imaging  

International Nuclear Information System (INIS)

Magnetic resonance (MR) imaging was performed in 26 patients with Ewing's sarcoma of bone preceding and following neoadjuvant chemotherapy, to assess tumour response non-invasively prior to surgery. T1- and T2-weighted spin echo images were obtained. Changes including intra- and extramedullary signal intensities, tumour demarcation, tumour volume and the appearance of residual extramedullary tumour were compared with histophathology of the resected specimens. Reduction of tumour volume was significantly higher in good responders. Other single parameters did not correlated with histologic tumour response. However, when several MR parameters summarized in a classification system were combined, a positive correlation with histopathologic response was found. A limited decrease of tumour volume (<25 %) and/or residual soft tissue mass following chemotherapy correlated with a poor response. An inhomogeneous, well-defined cuff of abnormal tissue ...

447

Magnetic resonance imaging of cerebral anomalies in subjects with resistance to thyroid hormone  

Energy Technology Data Exchange (ETDEWEB)

Resistance to thyroid hormone (RTH) is an autosomal dominant disease caused by mutations in the human thyroid receptor beta gene on chromosome 3. Individuals with RTH have an increased incidence of attention deficit hyperactivity disorder (ADHD). The purpose of this study was to search for developmental brain malformations associated with RTH. Forty-three subjects (20 affected males [AM], 23 affected females [AF]) with resistance to thyroid hormone and 32 unaffected first degree relatives (18 unaffected males [UM], 14 unaffected females [UF]) underwent MRI brain scans with a volumetric acquisition that provided 90 contiguous 2 mm thick sagittal images. Films of six contiguous images beginning at a standard sagittal position lateral to the insula were analyzed by an investigator who was blind with respect to subject characteristics. The presence of extra or missing gyri in the parietal bank of the Sylvian fissure (multimodal association cortex) and multiple Heschl`s ...

1995-06-19

448

GOCE, Satellite Gravimetry and Antarctic Mass Transports  

Science.gov (United States)

In 2009 the European Space Agency satellite mission GOCE (Gravity Field and Steady-State Ocean Circulation Explorer) was launched. Its objectives are the precise and detailed determination of the Earth's gravity field and geoid. Its core instrument, a three axis gravitational gradiometer, measures the gravity gradient components V xx , V yy , V zz and V xz (second-order derivatives of the gravity potential V) with high precision and V xy , V yz with low precision, all in the instrument reference frame. The long wavelength gravity field is recovered from the orbit, measured by GPS (Global Positioning System). Characteristic elements of the mission are precise star tracking, a Sun-synchronous and very low (260 km) orbit, angular control by magnetic torquing and an extremely stiff and thermally stable instrument environment. GOCE is complementary to GRACE (Gravity Recovery and Climate Experiment), another satellite gravity mission, ...

2011-03-01

449

Extension of improved particle and energy confinement regime in the core of LHD plasma  

International Nuclear Information System (INIS)

Recent two major topics of Large Helical Device (LHD) towards fusion relevant conditions, high-density operation and high-ion-temperature operation, are reported. Super dense core plasma was obtained by the combination of repetitive hydrogen ice pellet injection and high power neutral beam injection (NBI) heating. A very peaked density profile with the highest central density of 1.1x1021 m-3 was produced showing that the particle transport was suppressed very well in the plasma core. The spatial density varies as the position of magnetic axis (Rax), and the steepest profile is obtained at Rax=3.95 m. The highest central ion temperature of 5.6 keV was obtained in hydrogen plasma at electron density of 1.6 x 1019 m-3 by NBI, where a peaked ion-temperature profile with internal ion energy transport barrier was observed. The profile of electron temperature did not change much and was broad even when the ion temperature had a peaked profile. The ...

2009-06-01

450

Effect of electron irradiation on domain wall pinning defects in 50-50 NiFe  

International Nuclear Information System (INIS)

A magnetic measuring technique, which sorts out defects according to a distribution function n, was used to study the influence of electron irradiation on 50-50 NiFe. The distribution function is determined in terms of the maximum force f/subm/ that a defect can exert on a forward moving domain wall, or equivalently, the range z_0, which is the distance the mean position of the wall may move past the defect before the wall snaps free from the pinning action of the defect. The range and maximum force are related by a spring constant k, viz., f/subm/=kz_0. The quantity n (z_0) dz_0 gives the number of defects per unit volume having a range between z_0 and z_0+dz_0. Distribution functions were determined before and after electron irradiation. The irradiation was for 100 min with 18-MeV electrons with a dose of 1.1times10"1"7 e/cm"2. Following irradiation, there was a substantial decrease in the number of short-range defects (i.e., defects capable ...

451

Charge distribution analysis of catalysts under simulated reaction conditions. Second quarterly technical progress report, January 1, 1993--March 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

New furnaces were built based on fused silica with NiChrome heating elements custom-wound on alumina ceramic to self-compensate for induced magnetic fields during operation. During tests these furnaces failed due to thermal stresses caused by the high temperature cement used to hold the alumina ceramic in place. As a third solution pieces of boron nitride have been procured from which new furnace bodies will be machined during the third quarter. In order to increase the in-house capacity for machining ceramic parts a small lathe was ordered. The implementation of the LabView data acquisition software from National Instruments, Inc. took more time than anticipated and is still not completed. Major difficulties had to be overcome during the integration of the separate positive and negative high voltage supplies ({plus_minus}1000V). It became apparent that a custom-designed switch had to be installed to safeguard the data acquisition modules and ...

1993-11-01

452

How the Performance of a Superconducting Magnet is affected by theConnection between a small cooler and the Magnet  

Energy Technology Data Exchange (ETDEWEB)

As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the ...

2005-09-08

453

Anisotropic Nd{endash}Fe{endash}B bonded magnets made from HDDR powders (invited)  

Energy Technology Data Exchange (ETDEWEB)

Anisotropic Nd{endash}Fe{endash}B magnet powders can be produced by the hydrogenationdecomposition-desorption-recombination (HDDR) process from Nd{endash}Fe@ xnB{endash}Co{endash}M ({ital M}=Ga, Zr, Nb, Hf, and Ta) alloys. The present status of those HDDR powders and the bonded magnets made from them are reviewed with regards to the powder particle size dependence of their magnetic properties, their magnetic thermal stability, and their magnetization behavior. The results of a mechanistic study on the recombination step are also presented. The magnetic properties of the anisotropic HDDR powder depend relatively little on the powder particle size. Bonded magnets with a density of {approximately}6.20 g/cm{sup 3} and a BH{sub max} of 18.5{endash}20.5 MGOe can be produced from anisotropic HDDR powders with particle sizes of below 300 {mu}m diam. ...

1996-04-01

459

An Explanation for Positive Differential dc Voltage-Current Characteristics in Weakly Ionized, Low-Pressure Positive Column Gas Discharge Plasmas  

Energy Technology Data Exchange (ETDEWEB)

A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}

1996-07-01

460

Transmutations in fusion test facilities  

Science.gov (United States)

Using an expanded nuclear data base, the transmutation of PCA, AMCR33 (a reduced activation austenitic steel), HT-9, Rafer2 (a reduced activation ferritic steel), V-15%Cr-5%Ti alloy, and SiAlON (a ceramic) were calculated for two positions in the Fast Flux Test Facility (FFTF), three positions in the High Flux Isotope Reactor (HFIR), and the first wall position of both the STARFIRE and MARS conceptual fusion reactors. The peripheral test (PTP) position, and to a lesser extent the radial beryllium (RB) position, of HFIR show significant transmutations which are often in the opposite direction to the transmutations in the fusion conceptual designs. The positions in FFTF, as well as the hafnium covered location in the HFIR RB position show relative minor transmutations.

1986-04-01

461

Kondo effect and impurity-impurity interaction in (La, Ce)B_6 alloys  

International Nuclear Information System (INIS)

Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY ...

1978-01-01

462

Development of magnetic separation system of magnetoliposomes  

Energy Technology Data Exchange (ETDEWEB)

The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was ...

2009-10-15

463

Anti-cancer drug loaded iron-gold core-shell nanoparticles (Fe@Au) for magnetic drug targeting.  

Science.gov (United States)

Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus simulating the human ...

2010-09-01

464

"1"5"1Eu-Moessbauer study of complex magnetism in Eu_2PdSi_3: Effect of Eu"2"+ substitution by Y"3"+ and of high pressure  

International Nuclear Information System (INIS)

With "1"5"1Eu-Moessbauer spectroscopy and other methods the complex magnetic properties of Eu_2PdSi_3, arising from the two crystallographically different lattice sites of the Eu"2"+ ions, have been already studied. Here we study the impact of magnetic dilution of the magnetic Eu"2"+ sites by non-magnetic Y"3"+ ions. A previous specific heat study has found reduced magnetic ordering temperatures with strong indication of disorder effects like in magnetic spin glasses. Here we provide from "1"5"1Eu-Moessbauer spectroscopy detailed information of the impact of Y"3"+ substitution on the magnetic properties of the two lattice sites, well distinguishable in the "1"5"1Eu-spectra. Since the substitution of the larger Eu"2"+ ions by the smaller Y"3"+ ions is connected with a lattice contraction, we also applied high pressure to the Eu_2PdSi_3 sample ...

2010-03-01

465

Resistivity, Hall effect, and magnetic susceptibility of UPd_2Si_2  

International Nuclear Information System (INIS)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

466

Resistivity, Hall effect, and magnetic susceptibility of UPd[sub 2]Si[sub 2  

Energy Technology Data Exchange (ETDEWEB)

The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.

1993-12-15

467

Recycler model magnet test on temperature compensation for strontium ferrite  

Energy Technology Data Exchange (ETDEWEB)

The Recycler ring magnet will be made of Strontium ferrite permanent magnets. A strontium ferrite permanent magnet without compensation has a temperature coefficient of -0.2 % in dB/dT. To compensate this effect, we are utilizing 30 % Ni 70 % Fe alloy, a temperature compensation ferromagnetic material with a low Curie point. To search for optimum commercially available material and optimum condition, we made a couple of simple model magnets, and tested with several different compensating material. The test results are reported and its optimal conditions are shown. Several different configurations were tested including a possible 2 kG magnet configuration.

1995-10-01

468

Large specific absorption rates in the magnetic hyperthermia properties of metallic iron nanocubes  

CERN Document Server

We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large heating power.

2010-01-01

469

Effect of magnet sorting using a simple resonance cancellation method on the RMS orbit distortion at the APS injector synchrotron  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.

1993-07-01

470

Effect of On-Chip Magnetic Shielding for TES Microcalorimeters  

British Library Electronic Table of Contents (United Kingdom)

We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...

2008-01-01

471

Design, Performance and Series Production of Superconducting Trim Quadrupoles for the Large Hadron Collider  

CERN Document Server

The Large Hadron Collider (LHC) will be equipped with several thousands of superconducting corrector magnets. Among the largest ones are the superconducting trim quadrupoles (MQTL). These twin-aperture magnets with a total mass of up to 1700 kg have a nominal gradient of 129 T/m at 1.9 K and a magnetic length of 1.3 m. Sixty MQTL are required for the LHC, 36 operating at 1.9 K in and 24 operating at 4.5 K. The paper describes the design features, and reports the measured quench performance and magnetic field quality of the production magnets. The MQTL magnet production is shared between CERN and industry. This sharing is simplified due to the modular construction, common to all twin-aperture correctors.

2006-01-01

472

XPS study on the correlation between chemical state and oxygen-sensing properties of an iron oxide thin film  

International Nuclear Information System (INIS)

We have studied the correlation between the chemical state and the oxygen-sensing properties of an iron oxide thin film using a setup that allows simultaneous sensor resistance measurements and X-ray photoelectron spectroscopy (XPS) data acquisition. The gas exposures were performed at the highest operating pressure of the XPS spectrometer at a controlled sample temperature which allows direct comparison between the sensor response and the chemical state of the surface. The iron oxide film was modified by a sequence of argon ion sputtering steps and the induced changes in the chemical state, resistance, and sensitivity to oxygen were investigated. The sputtering was found to reduce the iron from the Fe"3"+ to the Fe"2"+ state and to decrease the sensor resistance. The measured sensitivity to oxygen first increased by a factor of two but then collapsed to its original level. The mechanism for oxygen sensing was found to be ...

2007-10-15

473

Tris(2,2prime-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Sol-Gel-Derived V2O5/Nafion Composite Films  

British Library Electronic Table of Contents (United Kingdom)

Mesoporous V2O5/Nafion composite films have been used for the immobilization of tris(2,2prime-bipyridyl)ruthenium (II) (Ru(bpy)$\\rm{ {_{3}^{2+}}}$) on an electrode surface to yield a solid-state electrogenerated chemiluminescence (ECL) sensor. The electrochemical and ECL behavior of Ru(bpy)$\\rm{ {_{3}^{2+}}}$ ion-exchanged into the composite films has been characterized as a function of the amount of Nafion incorporated into the V2O5/Nafion composite. The composite film with 80% Nafion content has the largest pore diameter (4.19 nm) and yields the maximum ECL response for tripropylamine (TPA) because of the fast diffusion of analyte into the film with large pores. Due to the enlarged pore size and enhanced conductivity of the V2O5/Nafion composite, the present ECL sensor based on the compo...

2006-01-01

474

Optoelectronic multipoint liquid level sensor for light petrochemical products  

Science.gov (United States)

In this article we describe an optoelectronic sensor for assessing the level of light petrochemical products in technological tanks at the oil refineries. This sensor employs the multi-element vertical array of discrete micro- optical refractometric transducers. The transducers are made of silica glass and have the conical shape. In the air, each transducer operates as a tiny retro-reflector that optically couple together two multimode optical fibers. The optical coupling in the transducer is due to the internal reflection at the conical surface. The amount of the coupling depends on the refractive index of the surrounding media. In a fluid, the total internal reflection vanishes and the coupling becomes negligibly small. The number of immersed transducers is a measure of the fluid level in the reservoir. Because of the significance of the transducer transmission function, it is evaluated in detail under various combinations of the geometrical ...

2000-06-01

475

Low-Cost, Robust, Threat-Aware Wireless Sensor Network for Assuring the Nation's Energy Infrastructure  

Energy Technology Data Exchange (ETDEWEB)

Eaton, in partnership with Oak Ridge National Laboratory and the Electric Power Research Institute (EPRI) has completed a project that applies a combination of wireless sensor network (WSN) technology, anticipatory theory, and a near-term value proposition based on diagnostics and process uptime to ensure the security and reliability of critical electrical power infrastructure. Representatives of several Eaton business units have been engaged to ensure a viable commercialization plan. Tennessee Valley Authority (TVA), American Electric Power (AEP), PEPCO, and Commonwealth Edison were recruited as partners to confirm and refine the requirements definition from the perspective of the utilities that actually operate the facilities to be protected. Those utilities have cooperated with on-site field tests as the project proceeds. Accomplishments of this project included: (1) the design, modeling, and simulation of the anticipatory wireless sensor ...

2007-03-31

476

Fire detection for conveyor-belt entries. Rept. of Investigations/1991  

Energy Technology Data Exchange (ETDEWEB)

The report details the results of a series of large-scale experiments where small coal fires were used to ignite conveyor belting at air velocities ranging from 0.76 m/s to 6.1 m/s. In the tests, electrical strip heaters imbedded within a pile of coal were used to heat the coal to a point of flaming ignition. The flaming coal subsequently ignited conveyor belting located approximately 5 to 10 cm above the coal pile. During the tests, temperature, CO, and smoke levels were continuously measured in order to determine both alarm time and level as the fire intensity progressed through the stages of smoldering coal, flame coal, and flaming coal plus flaming belt. Analysis of the data leads to certain conditions of air velocity and sensor alarm levels that are required for early detection of conveyor belt entry fires. Two nomographs are presented which define sensor alarm levels and sensor spacings as a function of belt entry ...

1991-01-01

477

Effect of gasoline octane quality on vehicle acceleration performance  

Energy Technology Data Exchange (ETDEWEB)

A study was conducted under the auspices of the Coordinating Research Council, Inc. (CRC) to assess the potential effects of gasoline octane quality on vehicle acceleration performance. Twelve participating laboratories, representing both the oil and the automotive industries, tested a total of 182 vehicles as part of the 1989 CRC Octane Number Requirement Survey. The vehicles consisted of 78 with electronic knock control systems and 104 without. All testing was performed using the 1989/1990 CRC FBRU fuel series. The results showed that acceleration performance of vehicles with knock sensors was significantly affected by gasoline octane quality. Octane effects on acceleration performance were most pronounced at maximum-throttle (detent) conditions and at octane levels below the vehicles' octane requirements; however, some knock-sensor vehicles did show improved acceleration performance with fuels at octane levels above the octane ...

1991-07-01

478

The concept of power correction techniques and its use in the reactor regulation and protection systems in Indian PHWRs  

International Nuclear Information System (INIS)

Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)

2010-02-01

479

The Authenticated Tracking and Monitoring System (ATMS) concept  

Energy Technology Data Exchange (ETDEWEB)

The Authenticated Tracking and Monitoring System (ATMS) has been designed to address the need for global monitoring of the status and location of proliferation-sensitive items. Conceived to utilize the proposed Global Verification and Location System (GVLS) satellite link, ATMS could use the existing International Maritime Satellite commercial communication system until GVLS is operational. The ATMS concept uses sensor packs to monitor items and environmental conditions, collects a variety of events data through a sensor processing unit, and transmits the data to a satellite, which then sends data to ground stations. Authentication and encryption algorithms will be used to secure the data. A typical ATMS application would be to track and monitor the safety and security of a number of items in transit along a scheduled shipping route. This paper also discusses a possible proof-of-concept system demonstration.

1993-08-01

480

Real-time monitoring of moisture levels in wound dressings in vitro: An experimental study  

British Library Electronic Table of Contents (United Kingdom)

Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time.A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate f...

2007-01-01

481

Oil-filled cable surveillance system using newly developed optical fiber gas sensor  

Energy Technology Data Exchange (ETDEWEB)

A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.

1996-04-01

482

Kolmogoroff constants at the 1976 ITCE  

Energy Technology Data Exchange (ETDEWEB)

The high-frequency data from 12 sensors at the ITCE 1976 are analyzed to determine the Kolmogoroff constants for velocity, temperature and humidity fluctuations, ..cap alpha../sub u/, ..cap alpha../sub T/, and ..cap alpha../sub q/. The occurrence of aliasing in the spectral analysis in some cases together with the limited response of some sensors at the higher frequencies introduces some uncertainties into the analysis. The Soviet sonic anemometer, fine-wire thermometer and infrared hygrometer and the Australian infrared hygrometer provide the best information, namely that: ..cap alpha../sub u/ = 0.59 +/- 0.01, ..cap alpha../sub T/ = 0.68 +/- 0.02, ..cap alpha../sub q/ = 0.76 +/- 0.03, where the errors quoted refer solely to statistical errors. The other instruments provide general support to these values. The technique of using spectral density measurements to determine eddy fluxes is illustrated.

1982-01-01

483

Inspection pig for gas pipeline  

Energy Technology Data Exchange (ETDEWEB)

The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory capacities to permit them to cope with in increased number of ...

1992-12-31

484

Focused ion beam fabrication and properties of nanoscale Josephson junctions for sensors and other applications  

International Nuclear Information System (INIS)

The methods of superconducting device fabrication by lithography and multilevel processing usually require a number of processing steps with lithographic resolution and alignment adequate for the scale of the device be fabricated. As an alternative, the focused ion beam (FIB) microscope is increasingly being used directly to fabricate devices. A major advantage of using a FIB compared to other lithography methods is its flexibility and high resolution. It allows in-situ, milling (#propor to#5 nm at a beam current of 1 pA) to a variety of depths, and imaging (2 nm) of the sample. In this paper we describe our development of junction fabrication techniques using the FIB and their application in creating a range of potential sensor devices and quantum electronics applications. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2005-03-01

485

Flood scour monitoring system using fiber Bragg grating sensors  

Science.gov (United States)

The exposure and subsequent undermining of pier/abutment foundations through the scouring action of a flood can result in the structural failure of a bridge. Bridge scour is one of the leading causes of bridge failure. Bridges subject to periods of flood/high flow require monitoring during those times in order to protect the traveling public. In this study, an innovative scour monitoring system using button-like fiber Bragg grating (FBG) sensors was developed and applied successfully in the field during the Aere typhoon period in 2004. The in situ FBG scour monitoring system has been demonstrated to be robust and reliable for real-time scour-depth measurements, and to be valid for indicating depositional depth at the Dadu Bridge. The field results show that this system can function well and survive a typhoon flood.

2006-12-01

486

Flexible, all-organic ammonia sensor based on dodecylbenzene sulfonic acid-doped polyaniline films  

International Nuclear Information System (INIS)

A stable chlorobenzene dispersion of conducting polyaniline (PANI) has been obtained by doping emeraldine base with dodecylbenzene sulfonic acid (DBSA) and studied by spectrophotometric measurements in the UV-vis-IR range. The electrical properties of PANI: DBSA films obtained from the above dispersion have been investigated under different temperature and relative humidity conditions. All-organic chemoresistive devices have been developed by spin-coating the PANI: DBSA dispersion on flexible substrates, and then by depositing electrodes on the top, from a carbon nanotube conducting ink. Sensing tests performed under exposition to calibrated amounts of ammonia reveal that these simple and inexpensive sensors are able to detect ammonia at room temperature in a reliable way, with a sensitivity linearly related to concentration in the range between 5 ppm and 70 ppm.

2010-09-30

487

Explosives sensor  

Energy Technology Data Exchange (ETDEWEB)

A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this device's construction and advantages are discussed in ...

1987-01-01

488

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

489

Application of remote sensing and geophysics to the detection and monitoring of acid mine drainage  

Energy Technology Data Exchange (ETDEWEB)

The results of a study on the application of remote sensing and geophysical methods for the detection and monitoring of acid mine drainage (AMD) are summarized, with emphasis on those that appear most suitable. The study consisted of a literature review, an information survey of users and suppliers, and discussions with various experts. Space-borne sensors, airborne sensors, airborne videography and digital frame cameras, spectroradiometers, radar, and photographic data are considered. Geophysical methods are effective for measurement of sulphides, areas of active chemical oxidation, acid mine drainage, and contaminated ground water movement. The popularity and effectiveness of various geophysical methods are rated for AMD applications. 25 refs., 1 fig., 3 tabs.

1995-06-01

490

Treatment of low-frequency pulsating magnetic field on amorphous alloy Fe_7_8Si_9B_1_3  

International Nuclear Information System (INIS)

Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe_7_8Si_9B_1_3 were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe_7_8Si_9B_1_3. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase (#alpha#-Fe(Si), the grain size, 2-10 nm) is 3-7%. The temperature rise ...

2007-07-15

491

The possible detection of magnetic monopoles and monopole tachyons  

International Nuclear Information System (INIS)

This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.

492

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

493

Room-temperature magnetic properties of oxy- and carbonmonoxyhemoglobin  

UK PubMed Central (United Kingdom)

The magnetic susceptibility and the density of human oxy-(HbO2) and carbonmonoxyhemoglobin (HbCO) solutions of various concentrations have been measured at room temperature, with pure water...Full Text Available

1978-10-01

494

Residential magnetic fields and childhood leukemia: a meta-analysis.  

UK PubMed Central (United Kingdom)

OBJECTIVES: This article uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies of residential magnetic field...Full Text Available

1998-12-01

495

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

496

Epidemiological appraisal of studies of residential exposure to power frequency magnetic fields and adult cancers.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To appraise epidemiological evidence of the purported association between residential exposure to power frequency magnetic fields and adult cancers. METHODS: Literature review and epidemiological...Full Text Available

1996-08-01

497

Electric and magnetic field exposures for people living near a 735-kilovolt power line.  

UK PubMed Central (United Kingdom)

The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available

1995-09-01

498

Design and experimental results on a terawatt magnetically controlled plasma opening switch  

Energy Technology Data Exchange (ETDEWEB)

The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load ...

1998-05-01

499

A case cohort study of suicide in relation to exposure to electric and magnetic fields among electrical utility workers.  

UK PubMed Central (United Kingdom)

OBJECTIVES--This case cohort study examines whether there is an association between exposure to electric and magnetic fields and suicide in a population of 21,744 male electrical utility workers from...Full Text Available

1996-01-01