WorldWideScience
1

Imaging magnetic domain structure in sub-500 nm thin film elements  

Energy Technology Data Exchange (ETDEWEB)

Magnetic imaging in the transmission electron microscope (TEM) has been used to examine submicron elements with the aim of discovering down to what element size complex domain patterns can form. The elements were squares, circles, triangles, and pentagons in the size range 100{endash}500 nm and were made from 36 nm Co films or 8 nm Ni{sub 80}Fe{sub 20} (NiFe) with in-plane magnetization. The magnetic domain structures in these elements were imaged at high resolution using the differential phase contrast imaging mode in a TEM. Nonuniform magnetization structures were seen in the images. Vortices were present at remanence in all shapes of 36-nm-thick Co elements down to 100 nm size and in circular NiFe elements down to 116 nm diameter. Triangular NiFe elements did not have a vortex ...

2001-06-01

2

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used ...

2005-04-01

3

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

5

Field driven ferromagnetic phase evolution originating from the domain boundaries in antiferromagnetically coupled perpendicular anitsotropy films  

Energy Technology Data Exchange (ETDEWEB)

Strong perpendicular anisotropy systems consisting of Co/Pt multilayer stacks that are antiferromagnetically coupled via thin Ru or NiO layers have been used as model systems to study the competition between local interlayer exchange and long-range dipolar interactions [1,2]. Magnetic Force Microscopy (MFM) studies of such systems reveal complex magnetic configurations with a mix of antiferromagnetic (AF) and ferromagnetic (FM) phases. However, MFM allows detecting surface stray fields only and can interact strongly with the magnetic structure of the sample, thus altering the original domain configuration of interest [3,4]. In the current study they combine magnetometry and state-of-the-art soft X-ray transmission microscopy (MXTM) to investigate the external field driven FM phase evolution originating from the domain boundaries in such antiferromagnetically coupled perpendicular ...

2008-05-01

14

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

16

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

17

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences  

International Nuclear Information System (INIS)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, ...

18

Domain structure of ferrite-garnet crystalline plates (111) with uniaxial anisotropy  

Energy Technology Data Exchange (ETDEWEB)

Magnetic field, thickness and magnetic forming effect on general mode and quantitative parameters of the domain structure (DS) of ferrite-garnet (EuEr)/sub 3/(FeGa)/sub 5/O/sub 12/ monocrystalline plates (111) is investigated. Field interval of circle (cone) and ring domain stability is determined. It is shown that DS of ferrite-garnet crystals with uniaxial an6sotropy has some peculiarities, that can be explained by cubic anisotropy effect.

1982-03-01

20

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

21

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow ...

2009-03-22

22

Clinical Assessment of Mirror Artifacts in Spectral-Domain Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available

2010-07-01

30

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

Energy Technology Data Exchange (ETDEWEB)

Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, ...

2008-07-15

31

Ordered magnetic nanohole and antidot arrays prepared through replication from anodic alumina templates  

International Nuclear Information System (INIS)

Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of ...

2008-07-01

32

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

33

Domain wall pining in a jointed ferromagnetic nano-wire  

Energy Technology Data Exchange (ETDEWEB)

The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.

2004-05-01

34

Magnetic domains in martensite of Ni-Mg-Ga alloy  

International Nuclear Information System (INIS)

The structural changes attendant on intermartensitic transformation in a Ni-Mg-Ga shape memory alloy are considered using magneto-optical visualization with the help of ferrite-garnet monocrystalline films. It is established that on the intermartensitic transformation the complete reorganization of martensite macrostructure fails. Martensite crystals resulted from the basic transformation change somewhat their sizes on intermartensitic transition. The existence of large-scale labyrinth magnetic domain structure is revealed

2006-05-01

35

Creation of an antiferromagnetic exchange spring  

Science.gov (United States)

We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.

2004-04-06

36

Romantic and Sexual Relationships, Body Image, and Fertility in Adolescent and Young Adult Testicular Cancer Survivors: A Review of the Literature  

UK PubMed Central (United Kingdom)

This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available

2010-08-01

37

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many ...

2010-01-01

38

Supersaturation of antiferromagnetically coupled multilayers: A comparative polarised neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

Reflectometric methods like polarised neutron reflectometry (PNR) and synchrotron Moessbauer reflectometry (SMR) are capable of investigating the plane-perpendicular and lateral magnetic structure of multilayers (MLs). Previously, a variety of domain formation and transformation phenomena was found and systematically studied in a Fe/Cr ML of strong antiferromagnetic coupling by PNR and SMR. Growth of the primary domains on passing the bulk-spin-flop transition was established. The domains were found to revert to their native state only in a field considerably higher than the apparent saturation field, a phenomenon referred to as the supersaturation domain memory effect (SDME). We present a comparative PNR study of two antiferromagnetically coupled Fe/Cr MLs with different magnetisation curves. We show that the distribution of the layer-layer coupling rather than the ...

2007-07-15

39

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

40

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

45

Lorentz transmission electron microscopy investigation of magnetically patterned Co/Pt multilayers  

Energy Technology Data Exchange (ETDEWEB)

The switching behavior of magnetic patterns prepared by ion irradiation was investigated. Co/Pt multilayers with perpendicular anisotropy and large out-of-plane coercivities 5-6 kOe were grown on electron transparent SiN windows. Regularly spaced 1 micron sized regions, were magnetically pattered via ion beam irradiation through a stencil mask. Lorentz TEM was used to observe in-situ magnetization reversal processes of irradiated regions under well-defined applied magnetic fields. When the in-plane field was increased, domain wall motion was observed, resulting in the alignment of the patterns with the direction of the applied field. The switching mechanism of the in-plane patterns was by domain wall motion.

2000-08-01

46

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

47

Extracting mining subsidence land from remote sensing images based on domain knowledge  

Energy Technology Data Exchange (ETDEWEB)

Extracting mining subsidence land from remote sensing (RS) images is one of important research contents for environment monitoring in mining area. The accuracy of traditional extracting models based on spectral features is low. In order to extract subsidence land from RS images with high accuracy, some domain knowledge should be imported and new models should be proposed. This paper, in terms of the disadvantage of traditional extracting models, imports domain knowledge from practice and experience, converts semantic knowledge into digital information, and proposes a new model for the specific task. By selecting the Luan mining area as a study area, this new model is tested based on GIS and related knowledge. The result shows that the proposed method is more precise than traditional methods and can satisfy the demands of land subsidence monitoring in mining area. 10 refs., 4 figs., 1 tab.

2008-06-15

48

Critical superparamagnetic/single-domain grain sizes in interacting magnetite particles: implications for magnetosome crystals  

UK PubMed Central (United Kingdom)

Magnetotactic bacteria contain chains of magnetically interacting crystals (magnetosome crystals), which they use for navigation (magnetotaxis). To improve magnetotaxis efficiency, the magnetosome crystals...Full Text Available

2009-12-06

49

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse ...

50

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the ...

1985-08-01

51

Wave extrapolation in the spatial wavelet domain with application to poststack reverse-time migration  

Energy Technology Data Exchange (ETDEWEB)

A wavelet transformation is performed over each of the spatial coordinates of the scalar wave equation. This transformed equation is solved directly with a finite-difference scheme for both homogeneous and smooth inhomogeneous media. Wavefield extrapolation is performed completely in the spatial wavelet domain without transforming back into the space domain at each time step. The wavelet coefficients are extrapolated, rather than the wavefield itself. The numerical solution of the scalar wave equation in the spatial wavelet domain is closely related to the finite-difference method because of the compact support of the wavelet bases. Poststack reverse-time migration is implemented as an application. The resolution spaces of the wavelet transform provide a natural framework for multigrid analysis. Migrated images are constructed from various resolution spaces.

1998-03-01

52

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

53

Magnetization and magnetostriction curves for highly magnetostrictive materials  

Energy Technology Data Exchange (ETDEWEB)

The macroscopic behavior of magnetostrictive materials results from domain evolutions occurring at a microscopic scale. The author shows how to compute magnetization and magnetostriction curves by appraising the behavior of the underlying microstructures. The method hinges on an averaging device (Young measures), which allows one to pass from the microscopic to the macroscopic scale. He takes into account the kinematical constraints on the accommodation of elastic effects, and he highlights the role of material symmetry in the selection of energetically optimal microstructures.

1994-12-31

54

J/Psi dissociation in parity-odd bubbles  

CERN Document Server

We calculate the quarkonium dissociation rate in the P and CP-odd domains (bubbles) that were possibly created in heavy-ion collisions. In the presence of the magnetic field produced by the valence quarks of colliding ions, parity-odd domains generate electric field. Quarkonium dissociation is the result of quantum tunneling of quark or antiquark through the potential barrier in this electric field. The strength of the electric field in the quarkonium comoving frame depends on the quarkonium velocity with respect to the background magnetic field. We investigate momentum, electric field strength and azimuthal dependence of the dissociation rate. Azimuthal distribution of quarkonia surviving in the electromagnetic field is strongly anisotropic; the form of anisotropy depends on the relation between the electric and magnetic fields and quarkonium momentum. These features can be used to ...

2011-01-01

55

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

56

Tarlov Cyst and Infertility  

UK PubMed Central (United Kingdom)

Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available

2009-04-01

58

Magnetic resonance imaging in human lymphodemas  

International Nuclear Information System (INIS)

The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).

1989-09-02

59

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

60

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

61

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

62

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

63

Determination of Inter-Phase Line Tension in Langmuir Films  

CERN Document Server

A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digital images of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of ...

2007-01-01

64

Nonlinear time-domain modeling of balanced-armature receivers  

DEFF Research Database (Denmark)

Nonlinear distortion added by the loudspeaker in a hearing aid lowers the signal-to-noise ratio and may degrade the hearing aid user's ability to understand speech. The balancedarmature- type loudspeakers, predominantly used in hearing aids, are inherently nonlinear devices, as any displacement of the loudspeaker diaphragm inevitably changes the magnetic and electrical characteristics of the loudspeaker. A numerical time-domain model capable of describing these nonlinearities is presented. By simulation it is demonstrated how the output distortion could potentially be reduced significantly through careful design of the mechanical properties of the armature.

2011-01-01

65

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

66

Circular map for supercavitating flow in a multiply connected domain  

British Library Electronic Table of Contents (United Kingdom)

A nonlinear free boundary-value problem of supercavitating flow past n + 1 hydrofoils is analyzed. To describe the cavities' closure mechanism, the Tulin-Terentev single-spiral-vortex model is employed. The flow domain is considered as the image of an (n + 1)-connected circular domain. The conformal map is constructed in terms of the solutions to two Riemann-Hilbert problems of the theory of symmetric automorphic functions. One of the problems is homogeneous and its coefficients are continuous functions while the second problem is inhomogeneous and has discontinuous coefficients. The exact solutions to the problems are found by using quasiautomorphic and quasimultiplicative analogs of the Cauchy kernel. The case of a single plate is considered in detail and the numerical results are report...

2009-01-01

67

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

68

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

69

Magnetic layer formation on plasma nitrided CoCrMo alloy  

British Library Electronic Table of Contents (United Kingdom)

In this study structural and magnetic character of the expanded austenite phase (gN) layer formed on a medical grade CoCrMo alloy by a low-pressure Radio-Frequency plasma nitriding process was investigated. The formation of the expanded austenite phase is facilitated at a substrate temperature near 400^oC for 1, 2, 4, 6 and 20h under a gas mixture of 60% N2-40% H2. The magnetic state of the gN layers was determined by a surface sensitive technique, magneto-optic Kerr effect (MOKE), and with a scanning probe microscope in magnetic force mode (MFM). Strong evidence for the ferromagnetic nature of the gN-(Co,Cr,Mo) phase is provided by the observation of stripe domain structures and the hysteresis loops. The ferromagnetic state for the gN phase observed here is mainly linked to large lattice ...

2011-01-01

70

Kinematics and flow characteristics of a magnetic actuated multi-cilia configuration  

British Library Electronic Table of Contents (United Kingdom)

The current paper continues the analysis of a completely novel method of fluid manipulation technology in micro-fluidics systems, inspired by nature, namely by the mechanisms found in ciliates. More information on this subject can be found at http://www.hitech-projects.com/euprojects/artic/. In order to simulate the drag forces acting on an array of artificial cilia, we have developed a computer code that is based on fundamental solutions of Stokes flow in a semi-infinite domain. The actuation mechanism consists of a bi-directional rotating excitation magnetic field. The magnetization induced by the magnetic field was calculated in a separate routine based on the Integral Nonlinear Equations Approach with 1D discretization of wire (cilium). Time averaged x-coordinate mass flow rates, strea...

2011-01-01

71

Symbolic image understanding. Final report Sep 87-Aug 90  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the work done at the University of Massachusetts in the area of Image Understanding of static scene domains. The goal of this research project was to demonstrate a practical knowledge-based approach to computer vision that utilized multiple levels of parallel processing. Some problems dealt with included extracting lines, grouping together regions and lines from the same surface, computing pose from geometry, and matching corresponding features in different views. Special attention was also given to the extraction of curved lines and curved surfaces. The static scene domains consisted of both ROAD and HOUSE scenes, each containing approximately fourteen (14) different objects per scene.

1991-11-01

72

Multi-domain, higher order level set scheme for 3D image segmentation on the GPU  

DEFF Research Database (Denmark)

Level set method based segmentation provides an efficient tool for topological and geometrical shape handling. Conventional level set surfaces are only $C^0$ continuous since the level set evolution involves linear interpolation to compute derivatives. Bajaj et al. present a higher order method to evaluate level set surfaces that are $C^2$ continuous, but are slow due to high computational burden. In this paper, we provide a higher order GPU based solver for fast and efficient segmentation of large volumetric images. We also extend the higher order method to multi-domain segmentation. Our streaming solver is efficient in memory usage.

2010-01-01

73

Amplitude preserved VSP reverse time migration for angle-domain CIGs extraction  

Science.gov (United States)

An improved method of generating angle-domain common-image gathers (ADCIGs) by VSP reverse time migration (RTM) is introduced in this paper. The formula which is used to compute the receiver wavefield for VSP RTM is modified by adding an amplitude correction term in order to conveniently output amplitude-preserved ADCIGs. Compared with the surface seismic data, VSP data contains much richer wavefields. However, the direct and downgoing waves can bring about serious imaging artifacts in ADCIGs, especially the direct wave. The feasibility and validity of this method is demonstrated by both numerical and real VSP data from western China. Thus, the ADCIGs from this method can provide reliable basic data for VSP migration velocity analysis, VSP AVO/AVA analysis, and inversion.

2011-06-01

74

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

75

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

76

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

77

Magnetic microstructure of candidates for epitaxial dual Heusler magnetic tunnel junctions  

Energy Technology Data Exchange (ETDEWEB)

Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.

2009-05-15

78

Comparison of stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic neurinomas according to 3-D tumor volume shrinkage and quality of life  

International Nuclear Information System (INIS)

Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% (SRS), and 87.5%/87.2% (SRT). TV shrinkage was 15.1%/40.7% ...

2009-09-01

79

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences; Funktionelle MRT des Pharynx bei obstruktiver Schlafapnoe (OSA) mit schnellen 2D-FLASH-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, ...

1996-03-01

80

Quality control in Nuclear Magnetic Resonance Imaging. Indications et strategies pour le controle de qualite en IRM  

Energy Technology Data Exchange (ETDEWEB)

In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.

1993-01-01

81

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

82

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

83

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system  

International Nuclear Information System (INIS)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).

84

Computer Algebra meets Finite Elements: an Efficient Implementation for Maxwell's Equations  

CERN Document Server

We consider the numerical discretization of the time-domain Maxwell's equations with an energy-conserving discontinuous Galerkin finite element formulation. This particular formulation allows for higher order approximations of the electric and magnetic field. Special emphasis is placed on an efficient implementation which is achieved by taking advantage of recurrence properties and the tensor-product structure of the chosen shape functions. These recurrences have been derived symbolically with computer algebra methods reminiscent of the holonomic systems approach.

2011-01-01

85

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

86

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...

2001-10-01

87

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

88

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The ...

2001-04-01

89

Preparation of Permalloy nanostructures using focused ion beam methods  

International Nuclear Information System (INIS)

Focused ion beam (FIB) milling is a powerful and versatile tool for the maskless fabrication of structures and devices at micro- and nanometer scales. The approach is based on the milling and deposition capabilities of a focused ion beam, where the latter is achieved by ion-beam-assisted decomposition of a metalorganic gas precursor of the specific material that has to be deposited. The combination of FIB and scanning electron microscopy in the same unit (so-called dual-beam unit) further expands the capabilities of the approach by the possibility of performing electron-beam-assisted deposition and inspection. Permalloy nanowires with electrical contacts patterned by FIB-Pt deposition were prepared in the dual-beam unit. Various types of notches to pin magnetic domain walls were additionally fabricated by means of FIB. The fabrication parameters for a structural modification of the Permalloy structures without too strongly affecting the ...

2010-03-21

90

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

91

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

92

Magnetic resonance imaging of the hip with a pelvic phased-array surface coil: a technical note  

Energy Technology Data Exchange (ETDEWEB)

Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution ...

1998-02-01

93

The Influence of Moderate Hypercapnia on Neural Activity in the Anesthetized Nonhuman Primate  

UK PubMed Central (United Kingdom)

Hypercapnia is often used as vasodilatory challenge in clinical applications and basic research. In functional magnetic resonance imaging (fMRI), elevated CO2 is applied to derive stimulus-induced...Full Text Available

2008-11-01

94

Teaching electron diffraction and imaging of macromolecules.  

UK PubMed Central (United Kingdom)

Electron microscopic analysis can be used to determine the three-dimensional structures of macromolecules at resolutions ranging between 3 and 30 A. It differs from nuclear magnetic resonance spectroscopy...Full Text Available

1993-05-01

95

Synthesis and characterization of PVP-coated large core iron oxide nanoparticles as an MRI contrast agent  

UK PubMed Central (United Kingdom)

The purpose of this study was to synthesize biocompatible polyvinylpyrrolidone (PVP)-coated iron oxide (PVP-IO) nanoparticles and to evaluate their efficacy as a magnetic resonance imaging (MRI)...Full Text Available

2008-04-01

96

Specialization along the Left Superior Temporal Sulcus for Auditory Categorization  

UK PubMed Central (United Kingdom)

The affinity and temporal course of functional fields in middle and posterior superior temporal cortex for the categorization of complex sounds was examined using functional magnetic resonance imaging...Full Text Available

2010-12-01

97

Retinal channelrhodopsin-2-mediated activity in vivo evaluated with manganese-enhanced magnetic resonance imaging  

UK PubMed Central (United Kingdom)

PurposeEctopic expression of light-sensitive proteins, such as channelrhodopsin-2, represent a novel approach for restoring light-detection capabilities to degenerated retina. A...Full Text Available

98

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

99

Neurosarcoidosis--demonstration of meningeal disease by gadolinium enhanced magnetic resonance imaging.  

UK PubMed Central (United Kingdom)

Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available

1991-06-01

100

Measuring the thickness of the human cerebral cortex from magnetic resonance images  

UK PubMed Central (United Kingdom)

Accurate and automated methods for measuring the thickness of human cerebral cortex could provide powerful tools for diagnosing and studying a variety of neurodegenerative and psychiatric disorders....Full Text Available

2000-09-26

101

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

102

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models  

UK PubMed Central (United Kingdom)

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation....Full Text Available

2009-05-01

103

MRI Findings of Pericardial Fat Necrosis: Case Report  

UK PubMed Central (United Kingdom)

Pericardial fat necrosis is an infrequent cause of acute chest pain and this can mimic acute myocardial infarction and acute pericarditis. We describe here a patient with the magnetic resonance imaging...Full Text Available

2011-05-01

106

Interictal Functional Connectivity of Human Epileptic Networks Assessed by Intracerebral EEG and BOLD Signal Fluctuations  

UK PubMed Central (United Kingdom)

In this study, we aimed to demonstrate whether spontaneous fluctuations in the blood oxygen level dependent (BOLD) signal derived from resting state functional magnetic resonance imaging (fMRI) reflect...Full Text Available

107

EXPONENTIAL TENSORS: A FRAMEWORK FOR EFFICIENT HIGHER-ORDER DT-MRI COMPUTATIONS  

UK PubMed Central (United Kingdom)

In Diffusion Tensor Magnetic Resonance Image (DT-MRI) processing a 2nd order tensor has been commonly used to approximate the diffusivity function at each lattice...Full Text Available

2007-05-15

108

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

109

Models of cardiac electromechanics based on individual hearts imaging data  

British Library Electronic Table of Contents (United Kingdom)

Current multi-scale computational models of ventricular electromechanics describe the full process of cardiac contraction on both the micro- and macro- scales including: the depolarization of cardiac cells, the release of calcium from intracellular stores, tension generation by cardiac myofilaments, and mechanical contraction of the whole heart. Such models are used to reveal basic mechanisms of cardiac contraction as well as the mechanisms of cardiac dysfunction in disease conditions. In this paper, we present a methodology to construct finite element electromechanical models of ventricular contraction with anatomically accurate ventricular geometry based on magnetic resonance and diffusion tensor magnetic resonance imaging of the heart. The electromechanical model couples detailed repres...

2011-01-01

110

Inborn Errors of Metabolism Presenting in Childhood  

British Library Electronic Table of Contents (United Kingdom)

Abstract Neurodegenerative and neurometabolic disorders may cause significant morbidity and mortality in children. Imaging is important in early diagnosis of metabolic disorders and in determining the extent of brain injury. Especially after the development of new techniques such as diffusion-weighted magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), neuroimaging plays more important role in the diagnosis and management of these disorders. In these disorders, usually a mutation causes a clinically significant block in one or more metabolic pathways. This blockage usually results in either a deficiency of the product or in an accumulation of substrate with damage induced by either storage or toxicity. The presenting symptoms are usually nonspecific. In some of the ...

2011-01-01

111

In vivo magnetic resonance techniques and drug discovery  

International Nuclear Information System (INIS)

The long and resource intensive process of drug discovery and development is confronted with the basic challenge of providing effective and safe therapies at reasonably low costs. The better the mechanism of a disease is known, the higher the probability to find an appropriate therapy. Also, the better and earlier a disease can be diagnosed and characterized, the higher the chance to be able to interfere in this process with a chemical entity. This reasoning sets the framework for the use of imaging in drug discovery. We discuss the relevance of magnetic resonance imaging and spectroscopy to derive anatomical, functional, metabolic and target-related information in the context of pharmacological research in vivo. (author)

2006-03-01

112

Cyberspace Domain: A Warfighting Substantiated Operational ...  

Science.gov (United States)

... CYBERSPACE DOMAIN: A ... 4. TITLE AND SUBTITLE Cyberspace Domain: A Warfighting Substantiated Operational Environment Imperative 5a. ...

2008-03-25

113

Photoreceptor Inner and Outer Segment Defects in Myopic Foveoschisis  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo evaluate pathologic features of the photoreceptors in myopic foveoschisis with the Fourier-domain optical coherence tomography (FD-OCT).DesignObservational case series.MethodsSeventeen eyes of 15 patients with myopic foveoschisis (foveal detachment type, six eyes; foveoschisis type, 11 eyes) were included. We observed the photoreceptor inner and outer segments (IS/OS) and evaluated the morphologic status using FD-OCT. Fundus photographs and time-domain OCT (TD-OCT) images also were obtained.ResultsIS/OS defects, which are uncommon in retinal detachments in eyes with myopia, were seen clearly in five eyes (three eyes [50%] with the foveal detachment type; two eyes [18%] with the foveal schisis type). Fundus photographs showed myopic chorioretinal atrophy in eight study eyes (47%),...

2008-01-01

114

Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?  

UK PubMed Central (United Kingdom)

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available

2009-03-01

115

Preparation and Characterization of Fe3O4/CdTe Magnetic/Fluorescent Nanocomposites and their Applications in Immuno-labeling and Fluorescent Imaging of Cancer Cells  

UK PubMed Central (United Kingdom)

The synthesis of a new kind of magnetic, fluorescent multifunctional nanoparticles (~30 nm in diameter) was demonstrated, where multiple fluorescent CdTe quantum dots (QDs) are covalently linked...Full Text Available

2010-01-19

116

Magnetic resonance appearance of fibromatosis  

International Nuclear Information System (INIS)

We reviewed retrospectively the magnetic resonance (MR) images of 14 soft-tissue lesions of fibromatosis (desmoid tumors) encountered in 11 patients. The lesions were typically inhomogeneous in texture and round to oval in configuration. Margins were well-defined in 78% of the lesions at presentation and were infiltrating in all recurrences. (orig./DG).

117

Metastatic Ewing's sarcoma to the skull: CNS involvement excluded by MRI  

International Nuclear Information System (INIS)

A case of metastatic Ewing's sarcoma to the skull is presented, demonstrating the superiority of magnetic resonance imaging over other imaging modalities to exclude CNS involvement. Precise delineation of different tumor components in extradural location contained in an intact dural rim together with compressed cortex showing no signs of tumorous involvement constituted an MRI appearance allowing us to exclude tumor outgrowth into the brain. (orig.).

118

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to ...

2009-03-01

119

Transmission electron microscopy characterisation of permalloy elements fabricated by focussed ion beam lithography  

International Nuclear Information System (INIS)

20 nm thick permalloy elements, with dimensions of 500 x 500 nm"2 and 1000 x 200 nm"2, have been fabricated on 50 nm thick silicon nitride substrate by milling using a focussed ion beam (FIB) microscope. The dose of ion beam used for the milling was varied in order to achieve the best definition for the milled areas. The FIB milled elements were characterised physically by atomic force microscopy (AFM) and bright field transmission electron microscopy (TEM) and magnetically by Fresnel imaging on a TEM modified for magnetic imaging. The FIB milled elements were found to have a more irregular edge and lower magnetic fields for events such as vortex annihilation when compared to elements of the same dimensions fabricated by conventional electron beam microscopy (EBL).

2006-02-22

120

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

121

Temporal measures and controls in ultrafast laser domain; Mesures et controles temporels dans le domaine des lasers ultrabrefs  

Energy Technology Data Exchange (ETDEWEB)

This work presents the development of a streak camera 'jitter free' sweep unit synchronized on a femtosecond laser. This application of high voltage photoconductive switches ('High voltage Auston switch') yields subpicosecond resolution for accumulated images on streak camera on a few hundreds micro joule femtosecond laser. Two others applications of these photoconductive switches are studied: - ultrafast optical commutation by a Pockels cell directly driven by a photoconductive switch (rising edge < 100 ps and jitter < 2 ps), - laser pulse energy self-stabilization experimentally proving that driving a Pockels cell by a photoconductive switch can increase the stability of the laser pulse energy from 7 % to 0.7 % rms. Additionally, the application of the acoustic-optical programmable dispersive filter (Dazzler) to the self referenced spectral phase measurement is presented. As these measurements require a linear ...

2004-12-15

122

Magnetic resonance imaging of the pediatric brain  

International Nuclear Information System (INIS)

The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.

123

IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT  

British Library Electronic Table of Contents (United Kingdom)

Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.

2011-01-01

124

Nucleon electromagnetic form factors from lattice QCD using 2+1 flavor domain wall fermions on fine lattices and chiral perturbation theory  

Science.gov (United States)

We present a high-statistics calculation of nucleon electromagnetic form factors in N{sub f}=2+1 lattice QCD using domain wall quarks on fine lattices, to attain a new level of precision in systematic and statistical errors. Our calculations use 32{sup 3}x64 lattices with lattice spacing a=0.084 fm for pion masses of 297, 355, and 403 MeV, and we perform an overdetermined analysis using on the order of 3600 to 7000 measurements to calculate nucleon electric and magnetic form factors up to Q{sup 2{approx_equal}}1.05 GeV{sup 2}. Results are shown to be consistent with those obtained using valence domain wall quarks with improved staggered sea quarks, and using coarse domain wall lattices. We determine the isovector Dirac radius r{sub 1}{sup v}, Pauli radius r{sub 2}{sup v} and anomalous magnetic moment {kappa}{sub v}. We also determine connected contributions to the corresponding ...

2010-02-01

125

A novel approach to personal photo album representation and management  

Science.gov (United States)

In this paper we present a novel approach to personal photo album management allowing the end user to efficiently access the collection without any need for tedious manual annotation or indexing of the photos. The proposed work exploits methods and technology from the field of computer vision and pattern recognition for face detection, face representation and image annotation to automatically create description of images useful for content-based searching and retrieval. In fact, even if most of the used techniques are not reliable enough to address the general problem of content-based image retrieval, we show that, in a limited domain such as the one of personal photo album, it is possible to obtain results that improve the browsing capabilities of current photo album management systems. In particular, starting from the observation that most personal photos depict a usually small number of people in a ...

2008-01-01

126

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection ...

127

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system; Interventionelle MR-Tomographie: Klinische Erfahrungen mit einem 1,5 Tesla System  

Energy Technology Data Exchange (ETDEWEB)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)

1997-05-01

128

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

129

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line ...

2002-08-01

130

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The ...

2008-04-15

131

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is ...

132

Structural and magnetic studies on the enhancement of the giant magnetoimpedance by ion irradiation  

British Library Electronic Table of Contents (United Kingdom)

The mechanism of abrupt increase of the giant magneto impedance (GMI) ratio in the ion irradiated Co-based amorphous ribbon has been investigated. The grazing incident X-ray diffraction and transmission electron microscope were used to characterize the samples before and after ion irradiation. The GMI-ratio considerably increased in the ion irradiated samples and the GMI response showed strong dependence on the driving frequencies. The Barkhausen noise (BN) signals are increased for the Ar ion irradiated sample with dose of 1x10^1^7 ion/cm^2. The results are interpreted in terms of GMI variation associated with domain wall dynamics.

2011-01-01

133

RBS Characterization of Yttrium Iron Garnet Thin Films  

International Nuclear Information System (INIS)

Magnetic materials such as yttrium iron garnet (YIG) are of great importance for its magneto-optic properties and for their potential applications in the domain of optical telecommunications. The deposition of thin films of YIG, on quartz or GGG (gadolinium gallium garnet) substrate, was performed using radio frequency non reactive magnetron sputtering, followed by high temperature annealing which is needed to enhance the crystallinity of the layers. Rutherford backscattering spectrometry RBS was used to determine the thickness and stoichiometry of the performed layers in order to investigate correlations between growth conditions and the quality of the final material. RBS measurements showed the influence of the deposition time and the temperature substrate on the film growth and its stoichiometry. (author)

2008-12-13

134

Images of very high energy cosmic ray sources in the Galaxy: I. A source towards the galactic centre  

Energy Technology Data Exchange (ETDEWEB)

Recent analyses of the anisotropy of cosmic rays at 10{sup 18} eV (the AGASA and SUGAR data) show significant excesses from regions close to the galactic centre and Cygnus. Our aim is to check whether such anisotropies can be caused by single sources of charged particles. We investigate propagation of protons in two models of the galactic regular magnetic field (with the irregular component included) assuming that the particles are injected by a short-lived discrete source lying in the direction of the galactic centre. We show that apart from a prompt image of the source, the regular magnetic field may cause delayed images at quite large angular distances from the actual source direction. The image is strongly dependent on the time elapsed after ejection of particles and it is also very sensitive to their energy. For the most favourable conditions for particle acceleration by a ...

2002-08-01

135

Polarised neutron reflectometry study of Co/CoO exchange-biased multilayers  

Energy Technology Data Exchange (ETDEWEB)

We have investigated via SQUID magnetometry and polarised neutron reflectivity the exchange-bias effect in CoO/Co sputtered multilayers. In particular, we studied the magnetisation reversal and the time relaxation of the exchange-bias field close to the coercive field H{sub c1}. Neutron intensities of all four cross sections (I++, I+-, I-+, I-) were recorded at the position of the first multilayer Bragg peak while scanning the magnetic field. From such scans we infer that the magnetisation reversal for the ascending as well as for the descending branch of the magnetic hysteresis occurs not by in-plane rotation but through domain-wall movements. The exchange-bias field, H{sub EB}, is strongly affected by thermal fluctuations. H{sub EB} decreases, following an exponential decay function with a half-life time of about 580 s at T=240 K. (orig.)

2002-07-01

136

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

137

Rotating magnetic tensor gradiometry and a superconducting implementation  

International Nuclear Information System (INIS)

This work describes the theoretical basis for a new concept rotating magnetic tensor gradiometer. The rotating gradiometer consists of an approximately axial or transverse gradiometer which is made to rotate about a perpendicular axis so that the direction of sensitivity is continually changing. It is demonstrated for the first time that the rotation separates gradient components of progressively higher-order in the frequency domain and enables absolute-value measurements of all components of the first-order magnetic gradient tensor, even if the magnetic sensors comprising the gradiometer are intrinsically incapable of absolute-value detection. In addition, the rotating gradiometer concept has a number of other advantages: the gradiometer imbalance is no longer directly determined by the engineering precision, the DC and low-frequency performance of the instrument is not limited by the performance of ...

2009-07-01

138

Shedding light on insight: Priming bright ideas  

British Library Electronic Table of Contents (United Kingdom)

Previous research has characterized insight as the product of internal processes, and has thus investigated the cognitive and motivational processes that immediately precede it. In this research, however, we investigate whether insight can be catalyzed by a cultural artifact, an external object imbued with learned meaning. Specifically, we exposed participants to an illuminating lightbulb - an iconic image of insight - prior to or during insight problem-solving. Across four studies, exposing participants to an illuminating lightbulb primed concepts associated with achieving an insight, and enhanced insight problem-solving in three different domains (spatial, verbal, and mathematical), but did not enhance general (non-insight) problem-solving.

2010-01-01

139

Pre-stack reverse-time migration for elastic waves with application to synthetic offset vertical seismic profiles  

Energy Technology Data Exchange (ETDEWEB)

A pre-stack migration algorithm for elastic waves in two-dimensional variable-velocity media is developed, implemented, and tested. The algorithm operates in the time-space domain and is based on reverse-time finite-difference extrapolation of elastic waves. The algorithm is explained and demonstrated in the context of imaging of elastic vertical seismic profile data, but is applicable to any source-recorder geometry. Synthetic test examples include a point diffractor, laterally homogeneous layers, and the flank of a salt dome.

1986-03-01

140

Development of Intelligent Setting System for Fracture Based on X-Ray Image  

Energy Technology Data Exchange (ETDEWEB)

In order to achieve micro-wound, intelligence and high efficiency for fracture setting, intelligent setting system for fracture is proposed in accordance with biomechanics and fracture therapy theory. In the comprehensive medical system based on C-shape-arm X-machine, image processing and analysis is the core, programmable logical controller and stepping motor are important driving parts controlling mechanical parts. Six degree of freedom dynamics sensor ensures to control accurately force and moment. On the foundation of analyzing X-ray image peculiarities, method of processing and analysis is put forward, combining time domain with frequency domain. After mining domain knowledge in depth, setting actions is quantized into three non-continuous steps and is parameterized into two angles and one distance aiming at femoral-neck fracture. Objective features are extracted by virtue of ...

2006-10-15

141

Scoring of brain maturation in developmentally handicapped children with high-field MR imaging  

International Nuclear Information System (INIS)

A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.

142

The accurate magnetic structure of CeAl{sub 2} at various temperatures in the ordered state  

Energy Technology Data Exchange (ETDEWEB)

The magnetic structure of the cubic compound CeAl{sub 2} is incommensurate and double-k. The moments on the two Ce sites describe two elliptical helices of opposed chiralities and lie in the (11-bar0) plane, with their Fourier components m{sup k} close to the [111] direction. Recent symmetry considerations, including for the first time the inversion center of the crystal, have reduced the number of parameters of this structure and have underlined the existence of a phase difference between the projections m{sub x}{sup k}, m{sub y}{sup k} and m{sub z}{sup k} of m{sup k}. Up to now, although many neutron investigations have been carried out on CeAl{sub 2} single crystals, no set of magnetic intensities was available which was large and good enough to check whether this phase difference exists or not. We have measured such a set of data, taking great care of the instrumental resolution in order to avoid unwanted contributions to the intensities ...

2008-04-02

143

The accurate magnetic structure of CeAl_2 at various temperatures in the ordered state  

International Nuclear Information System (INIS)

The magnetic structure of the cubic compound CeAl_2 is incommensurate and double-k. The moments on the two Ce sites describe two elliptical helices of opposed chiralities and lie in the (11-bar0) plane, with their Fourier components m"k close to the [111] direction. Recent symmetry considerations, including for the first time the inversion center of the crystal, have reduced the number of parameters of this structure and have underlined the existence of a phase difference between the projections m_x"k, m_y"k and m_z"k of m"k. Up to now, although many neutron investigations have been carried out on CeAl_2 single crystals, no set of magnetic intensities was available which was large and good enough to check whether this phase difference exists or not. We have measured such a set of data, taking great care of the instrumental resolution in order to avoid unwanted contributions to the intensities from other domains. As the ...

2008-04-02

144

Optical image storage in ion implanted PLZT ceramics  

International Nuclear Information System (INIS)

We have demonstrated that optical images can be stored in transparent lead-lanthanum-zirconate-titanate (PLZT) ceramics by exposure to near-UV light with photon energies greater than the band gap energy of approx. equal to 3.35 eV. The image storage process relies on optically induced changes in the switching properties of ferroelectric domains (photoferroelectric effect). Stored images are nonvolatile but can be erased by uniform UV illumination and simultaneous application of an electric field. Although high quality images, with contrast variations of >= 100:1 and spatial resolution of approx. equal to 10 #mu#m, can be stored using the photoferroelectric effect, relatively high exposure energies (approx. equal to 100 mJ/cm"2) are required to store these images. This large exposure energy severely limits the range of possible applications of nonvolatile ...

145

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high ...

2008-06-01

146

Microstructure and magnetic properties of nanocrystalline Fe75Si20M5 (M = Al, B, Cr) powders  

International Nuclear Information System (INIS)

Nanocrystalline Fe75Si20M5 (M = Al, B and Cr) powders were synthesized by mechanical alloying in a planetary ball mill from high purity elemental powders. Evolution of non-equilibrium solid solutions of ?-Fe[Si,(Al, B, Cr)] with a nanocrystalline structure was accompanied by the introduction of a large number of dislocation defects in the course of the milling process. Fe sites get substituted by Si and M (M = Al, B, Cr) atoms during the milling process. The structural change and the resulting disorder are reflected in the changes in the lattice parameter and average magnetic moment of the powders milled for various time periods. The effective magnetic anisotropy increases linearly with the milling time. An increase in coercivity with increasing milling time was observed which could be attributed to the introduction of dislocations and the reduction in the powder particle size during milling. The presence of dislocations and grain boundaries ...

2008-08-21

147

Magnetic and superconducting quantum critical points of heavy-fermion systems  

Energy Technology Data Exchange (ETDEWEB)

Two examples of heavy-fermion systems are presented : CePd{sub 2}Si{sub 2}, an antiferromagnet with a quantum critical point at P{sub C}=28 kbar and UGe{sub 2} an itinerant ferromagnet which transits in a paramagnetic phase above P{sub C}=16 kbar. In CePd{sub 2}Si{sub 2} the superconductivity domain is centered on P{sub C}. Special attention was given to the superconducting and magnetic anomalies at their superconducting and Neel temperatures. In UGe{sub 2} superconductivity appears in 9 kbar at a temperature T{sub S}, more than two orders of magnitude lower than the Curie temperature; furthermore, it occurs only on the magnetic border (P<P{sub C}). Another characteristic temperature T{sub X} is detected by resistivity; the zigzag uranium chain of the lattice may favor a supplementary nesting in the majority spin band.

2001-05-01

148

Direct energy conversion for IEC fusion for space applications  

Energy Technology Data Exchange (ETDEWEB)

The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It ...

2000-08-01

149

A Wide-Band Electromagnetic Impedance Profiling System forNon-Invasive Subsurface Characterization  

Energy Technology Data Exchange (ETDEWEB)

A non-invasive, wide-band electromagnetic (EM) impedance difference system for shallow subsurface electrical structure characterization in environmental and engineering problems has been developed at the Lawrence Berkeley National Laboratory (LBNL). Electrical parameters of interest are electrical conductivity and dielectric permittivity that are deduced from the impedance difference data. The prototype system includes a magnetic loop transmitter, which operates between 0.1 MHz and 100 MHz, an electrical dipole antenna for observing the electric field, and a loop antenna for measuring the magnetic field.All antennas are mounted on a cart made of non-metallic material for easy movement of the whole array for profiling. Surface EM impedance difference is obtained by taking the difference of the ratios of the electric fields to the magnetic fields at selected frequencies at two different levels. Numerical simulations will be ...

2004-12-17

150

Primary cutaneous Ewing's sarcoma/primitive neuroectodermal tumor manifesting numerous small and huge ulcerated masses: its complete remission by chemotherapy and magnetic resonance imaging findings  

International Nuclear Information System (INIS)

Extraskeletal Ewing's sarcoma (ES) and primitive neuroectodermal tumor (PNET) are widely regarded as clinically and histologically identical tumors which consist of small blue round cells. Extraskeletal ESs/PNETs usually occur in the deep soft tissues of the paraspinal region, chest wall, or lower extremities. However, superficially located cases, so-called cutaneous ESs/PNETs, are exceedingly rare, and the vast majority of the reported cases present as a single small mass. We present magnetic resonance imaging (MRI) findings and clinical course of a unique case of primary cutaneous ES/PNET presenting as numerous huge masses with severe ulceration on them. (orig.)

2010-06-01

151

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

152

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

153

Magnetic resonance imaging in patients with heart valve prostheses  

International Nuclear Information System (INIS)

Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular regurgitation was easy to differentiate from ...

154

Magnetic resonance appearance of peripheral nerve sheath tumors  

International Nuclear Information System (INIS)

Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship ...

155

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to ...

2010-10-01

156

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks ...

2010-11-21

157

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically ...

1997-01-01

158

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

159

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent ...

2008-04-15

160

Reverse time migration for ground penetrating radar using finite difference time domain method; Jikan ryoiki yugenn sabunho ni yoru chichu reda no ribasu taimu maigureshon  

Energy Technology Data Exchange (ETDEWEB)

The reversion time migration, as one of reflection seismic prospecting migration, reverse propagates a wave equation by reverse promoting the differential time, and conducts the migration. The method has such merits as no limit to the inclined angle of a reflection, correspondence to a complex topography etc. And, there is a finite difference time domain (FDTD) that uses the Maxwell equation as it is and makes a difference approximation in the methods differentiating and resolving electro-magnetic fields. It is also possible to apply the reverse time migration onto it. In this speech, using an explosive reflection face, a slope 2 layer structure and models of its reflection points are synthesized by a ground penetrating radar using the FDTD, and reverse time migration is conducted. As a result, it is clarified that the reverse time migration is valid for the ground penetrating radar recording. And, the cases including a diffusion item in the ...

1999-02-01

161

Representation of uncertainty in computer vision using fuzzy sets  

Energy Technology Data Exchange (ETDEWEB)

Uncertainty in computer vision can arise at various levels. It can occur in the low level in the raw sensor input, and extends all the way through intermediate and higher levels. Ideally, at any level where decisions are being made on the basis of previous processing steps, a computer vision system must have sufficient flexibility for representation of uncertainty in any of these levels. The input cue representation portion of a computer vision system should maintain the information content of the original input images, while at the same time allowing for uncertainty in the identification of attributes required by other parts of the system for decision making. Processes such as edge detection, segmentation, and shape matching yield results which could bias higher level decision making, unless some framework is defined for the representation of uncertainty in the context of fuzzy set theory where membership values associated with the fuzzy sets contain a consistent ...

1986-02-01

162

On the calculation of scattered fields by 3-D structure in the time-domain electromagnetic (TDEM) method; Jikan ryoiki denjiho ni okeru sanjigen kozo kara no sanranba no keisan ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the calculation method of 3-D underground structures in TDME method which measures only field components. Recently, FDTD method was developed as calculation method in time domain difference calculus, and the forward analysis accuracy of 3-D fields was rapidly improved. The survey results using a large-scale loop (600m{times}360m) were numerically analyzed by FDTD method. 16 measuring lines were prepared in both X and Y directions, and measuring points were prepared on intersection points of the measuring lines. Since signal current is staircase one, step and impulse responses of the ground were determined by calculating magnetic field and its time differentiation. The rectangular body (120m{times}120m{times}100m) of 0.2S/m in conductivity (5 ohm m in resistivity) was installed 160m under the ground as 3-D resistivity anomaly. The ground of 0.01S/m (100 ohm m) was assumed. Time variation in horizontal ...

1996-10-01

163

Choosing the Right Solution Approach: The Crucial Role of Situational Knowledge in Electricity and Magnetism  

Science.gov (United States)

Novice problem solvers are rather sensitive to surface problem features, and they often resort to trial and error formula matching rather than identifying an appropriate solution approach. These observations have been interpreted to imply that novices structure their knowledge according to surface features rather than according to problem type categories. However, it may also be the case that novices do know problem types, but cannot map the problem at hand to a known type, because they fail to create a sufficiently well-elaborated problem representation. This study aims to distinguish between these explanations. In this study novice physics students at high and low levels of proficiency completed two problem-sorting tasks from the domain of electricity and magnetism, one with and one without elaboration support. Results confirm that these students do distinguish problem types in accordance with their required solution approaches, and that ...

2010-12-01

164

Ectopic expression of wild-type or a dominant-negative mutant of transcription factor NTF-1 disrupts normal Drosophila development.  

Science.gov (United States)

The Drosophila melanogaster tissue-specific transcription factor NTF-1 was originally identified in vitro as a protein that could bind to and activate transcription from the Dopa decarboxylase (Ddc) gene. A structure-function analysis of NTF-1 led to the identification of a discrete amino-terminal activation domain. Here, we report that an NTF-1 mutant lacking the activation domain acts as a trans-dominant inhibitor of NTF-1 activation in tissue culture cells by forming inactive heterodimers with the full-length protein. Ectopically expressing this dominant-negative protein or the full-length protein in developing Drosophila embryos leads to dire developmental consequences. Overexpressing the trans-dominant NTF-1 leads to lethality, while overexpressing full-length NTF-1 results in both lethality and morphogenetic defects. Our results suggest that both the activity and the regulation of NTF-1 are critical for viability and proper development of ...

1993-11-15

165

Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children  

Energy Technology Data Exchange (ETDEWEB)

Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other ...

1998-11-01

167

A genome-wide study of PDZ-domain interactions in C. elegans reveals a high frequency of non-canonical binding  

UK PubMed Central (United Kingdom)

BackgroundProteins may evolve through the recruitment and modification of discrete domains, and in many cases, protein action can be dissected at the domain level. PDZ domains are...Full Text Available

168

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with ...

1997-05-01

169

THE EFFECT OF VARIABLE THERMAL CONDUCTIVITY ON MICRO-POLAR FLUID FLOW BY CHEBYSHEV COLLOCATION METHOD  

British Library Electronic Table of Contents (United Kingdom)

In this article, the authors analyzed the effect of thermal conductivity on unsteady magnetohydrodynamic (MHD) free convection in a micro-polar fluid past a semi-infinite vertical porous plate. The fluid thermal conductivity is assumed to vary as a linear function of temperature. By using the Chebyshev collocation method in the spatial direction and the Crank-Nicolson method in the time direction, the boundary layer equations are transformed into a linear algebraic system. There are several material parameters whose affect on the flow have been studied, for instance, thermal conductivity, radiation, magnetic, micro-polar, suction (or injection) parameters, and Prandtl number. Boundary layer and Boussineq approximations have been introduced together to describe the flow field. The domain of...

2010-01-01

170

Recent Energy Saving Technologies on Railway Traction Systems  

British Library Electronic Table of Contents (United Kingdom)

Energy saving technologies in the railway vehicle traction field can be mainly categorized into two domains: reducing loss and increasing the regenerative energy. Energy saving technologies for the traction equipment by the use of power converters with less loss and high-efficiency permanent magnet synchronous motors are introduced. The regenerative brake related technologies are also presented as another measure to save the energy, including the improvement of the regenerative brake control and application of energy storage devices. It is concluded that the benefit of the energy saving technology is not only the energy saving itself but also downsizing traction equipments and reducing the maintenance work in the electrical railway system. Copyright Copyright 2010 Institute of Electrical E...

2010-01-01

171

Nano photonic sensors for microdamage detection : an exploratory simulation.  

Energy Technology Data Exchange (ETDEWEB)

Nano photonic materials are synthetically manufactured crystals at the nano scale with the target of creating a microstructure with a special electro-magnetic periodicity. Such nano photonic materials have the ability to control light propagation and thus are capable of creating photonic bandgaps in the frequency domain. We propose using nano photonic crystals as sensors to detect microdamage in composite materials. We demonstrate using a simulation model that a nano photonic sensor attached to a composite bar experiences a significant change in its bandgap profile when damage is induced in the composite bar. The model predicts the frequency response of the nano photonic sensor using the transfer matrix method. A damage metric to evaluate the change in the frequency response is developed. Successful developments of nano photonic sensors allow damage identification at scales not attainable using current sensing technologies.

2005-04-01

172

The brain-derived neurotrophic factor Val66Met polymorphism is associated with reduced functional magnetic resonance imaging activity in the hippocampus and increased use of caudate nucleus-dependent strategies in a human virtual navigation task  

UK PubMed Central (United Kingdom)

Multiple memory systems are involved in parallel processing of spatial information during navigation. A series of studies have distinguished between hippocampus-dependent ‘spatial’ navigation,...Full Text Available

2011-03-01

173

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

174

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

175

MRI and 1H MRS of The Breast: Presence of a Choline Peak as Malignancy Marker is Related to k21 Value of the Tumor in Patients with Invasive Ductal Carcinoma  

UK PubMed Central (United Kingdom)

To assess which specific morphologic features, enhancement patterns, or pharmacokinetic parameters on breast Magnetic Resonance Imaging (MRI) could predict a false-negative outcome of Proton...Full Text Available

2008-01-01

176

MR findings of primary Ewing's sarcoma of greater wing of sphenoid  

International Nuclear Information System (INIS)

Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd

2002-12-01

177

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The ...

2009-03-15

178

The magnetic resonance and its agro-industry applications; a review  

International Nuclear Information System (INIS)

The electromagnetic properties that present hydrogen and other nucleus of agro-alimentary products, have allowed widely use of magnetic resonance (MR) to study the composition and internal structure of these biological materials in a micro and macroscopic scale, in a nondestructive way. In this paper the physical principles, basic equipment to measure the MR signals and the MR imaging of any biological sample, are explained. It is also shown a review of the main agro-alimentary applications, emphasizing in the use of this principle to examine the internal quality of fruits and vegetables. In these products, the MR has been used to detect and follow the evolution of different factors that determine the internal quality after harvesting, during storage and after post harvesting processes. The main studies that have been conducted with MR in harvested products are about physiological disorders that take place during storage and conservation of ...

179

Evaluation of magnetization transfer ratios for breast tissues and breast diseases  

Energy Technology Data Exchange (ETDEWEB)

To determine MTRs for normal structures and benign diseases in the breast two-dimensional magnetization transfer imaging was performed in 62 patients and in 3 young female volunteers. With regard to the MTRs of measurements in the normal breast tissues, fat tissues which is close to simple cysts in MTRs show little transfer of longitudinal magnetization. MTRs of the muscles was 15.15{+-}6.22%, which exceeded those of breast parenchyma. The breast parenchyma didn`t show the change of MTR value due to the difference of patient age and due to variable amount of fat and fibrous tissues. Breast parenchyma in the two young volunteers clearly showed biphasic change of MTR values in accordance with the menstrual cycle; little transfer value was due to hydration in the postovulatory period and high transfer value was due to dehydration in the preovulatory period. In the remaining one volunteer during lactation period, mammary ...

1997-03-01

180

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of ...

1991-09-15

181

Evaluation of fetal brain development by magnetic resonance imaging. Subependymal germinal matrix layer and cerebral ventricle  

International Nuclear Information System (INIS)

Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The relation between fetal ages and volume of cerebral ventricle also showed similar pattern. This method will be ...

1999-10-01

182

Estimation of plasma density by surface plasmons for surface-wave plasmas  

International Nuclear Information System (INIS)

An estimation method of plasma density based on surface plasmons theory for surface-wave plasmas is proposed. The number of standing-wave is obtained directly from the discharge image, and the propagation constant is calculated with the trim size of the apparatus in this methods, then plasma density can be determined with the value of 9.1 x 1017 m-3. Plasma density is measured using a Langmuir probe, the value is 8.1 x 1017 m-3 which is very close to the predicted value of surface plasmons theory. Numerical simulation is used to check the number of standing-wave by the finite-difference time-domain (FDTD) method also. All results are compatible both of theoretical analysis and experimental measurement. (authors)

2008-12-01

183

A Laplacian approach to multi-oriented text detection in video.  

Science.gov (United States)

In this paper, we propose a method based on the Laplacian in the frequency domain for video text detection. Unlike many other approaches which assume that text is horizontally-oriented, our method is able to handle text of arbitrary orientation. The input image is first filtered with Fourier-Laplacian. K-means clustering is then used to identify candidate text regions based on the maximum difference. The skeleton of each connected component helps to separate the different text strings from each other. Finally, text string straightness and edge density are used for false positive elimination. Experimental results show that the proposed method is able to handle graphics text and scene text of both horizontal and nonhorizontal orientation. PMID:20733217

2011-02-01

184

Characterization of proton exchange membrane materials for fuel cells by solid state nuclear magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel model gives the measured S/V ratios in the normal hydration ...

2010-03-15

185

Effect of electron irradiation on domain wall pinning defects in 50-50 NiFe  

International Nuclear Information System (INIS)

A magnetic measuring technique, which sorts out defects according to a distribution function n, was used to study the influence of electron irradiation on 50-50 NiFe. The distribution function is determined in terms of the maximum force f/subm/ that a defect can exert on a forward moving domain wall, or equivalently, the range z_0, which is the distance the mean position of the wall may move past the defect before the wall snaps free from the pinning action of the defect. The range and maximum force are related by a spring constant k, viz., f/subm/=kz_0. The quantity n (z_0) dz_0 gives the number of defects per unit volume having a range between z_0 and z_0+dz_0. Distribution functions were determined before and after electron irradiation. The irradiation was for 100 min with 18-MeV electrons with a dose of 1.1times10"1"7 e/cm"2. Following irradiation, there was a substantial decrease in the number of short-range defects (i.e., defects capable ...

186

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...

2003-03-01

187

New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik  

Energy Technology Data Exchange (ETDEWEB)

Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical studies are needed, they are a promising possibility for improving MR ...

1993-12-31

189

Low-frequency fields - sources and exposure; Niederfrequente Felder - Quellen und Exposition  

Energy Technology Data Exchange (ETDEWEB)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe) [Deutsch] Nach einer kurzen Diskussion der Begriffsdefinitionen und einer Einfuehrung in die Messtechnik werden die Charakteristika verschiedener ...

1993-06-01

190

CuPt-type ordering of MOCVD In{sub 0.49}Al{sub 0.51}P.  

Science.gov (United States)

CuPt-type ordering in In{sub 0.49}Al{sub 0.51}P is studied by TEM. The lattice-matched film was grown by MOCVD on a GaAs substrate oriented 10{sup o} off (001) towards [110], at 650 C and 25 nm/min. TEM [110] and [1{bar 1}0] cross-sections (XS) were made by wedge polishing and 2 kV Ar ion milling. In CuPt-type ordering of In{sub 0.52}Ga{sub 0.48}P, alternating In-Ga-In-Ga {l_brace}111{r_brace} planes of group III atoms produce 1/2 {bar 1}11 and 1/2 1{bar 1}1 order spots in the 110 SADP, while the [1{bar 1}0] SADP shows no order spots [1-3]. A few studies have reported this type of order in In{sub 0.49}Al{sub 0.51}P [4]. The 004 BF image of the [1{bar 1}0] XS in Fig. 1 shows uneven light/dark contrast modulation due to phase separation often observed in In{sub 0.52}Ga{sub 0.48}P. There are also light/dark layers marked ML parallel to the film growth plane; such unintentional multilayers have also been observed [5] but their origin is not understood. Order lamellae ...

2002-03-14

191

PDE-based Non-Linear Diffusion Techniques for Denoising Scientific and Industrial Images: An Empirical Study  

Energy Technology Data Exchange (ETDEWEB)

Removing noise from data is often the first step in data analysis. Denoising techniques should not only reduce the noise, but do so without blurring or changing the location of the edges. Many approaches have been proposed to accomplish this; in this paper, they focus on one such approach, namely the use of non-linear diffusion operators. This approach has been studied extensively from a theoretical viewpoint ever since the 1987 work of Perona and Malik showed that non-linear filters outperformed the more traditional linear Canny edge detector. They complement this theoretical work by investigating the performance of several isotropic diffusion operators on test images from scientific domains. They explore the effects of various parameters such as the choice of diffusivity function, explicit and implicit methods for the discretization of the PDE, and approaches for the spatial discretization of the non-linear operator etc. They also compare ...

2001-12-20

192

Time-varying magnetic fields increase cytosolic free Ca sup 2+ in HL-60 cells  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic fields have been reported to cause a variety of biological effects. It has been hypothesized that many of these phenomena are mediated by a primary effect on the concentration of cytosolic free calcium ((Ca2+)i). We investigated the effects of exposure to electromagnetic fields on (Ca2+)i in HL-60 cells using the Ca2(+)-sensitive fluorescent indicator indo-1. Indo-1-loaded cell samples were exposed to a radiofrequency electromagnetic field, a static magnetic field, and a time-varying magnetic field, which were generated by a magnetic resonance imaging (MRI) unit. We found that a 23-min exposure to all three fields, in combination, induced a significant increase in (Ca2+)i of 31 +/- 8 (SE) nM (P less than 0.01, n = 13) from a basal level of 121 +/- 8 nM. Also, cells exposed to only the time-varying magnetic field had a mean (Ca2+)i that was 34 +/- 10 nM (P less than ...

1990-10-01

193

Soft tissue manifestations of early rheumatic disease. Imaging with MRI  

International Nuclear Information System (INIS)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). ...

2006-08-01

194

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal ...

1998-06-01

195

Magnetic resonance imaging assessment of brain maturation in preterm neonates with punctate white matter lesions  

International Nuclear Information System (INIS)

Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with ...

2007-02-01

196

Value of MRCP using oral Gd-DTPA as negative contrast materials in diagnosis of atypical juxtapapillary duodenal diverticulum  

British Library Electronic Table of Contents (United Kingdom)

Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imaging findings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...

2009-01-01

197

The role of MRI in the diagnosis of recurrent/persistent carpal tunnel syndrome: A radiological and intra-operative correlation  

British Library Electronic Table of Contents (United Kingdom)

MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...

2011-01-01

198

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

199

Magnetic resonanse imaging in otorhinolaryngology. With special reference to the influence of factors upon NMR parameters and differential diagnosis of otorhinolaryngic lesions  

Energy Technology Data Exchange (ETDEWEB)

MRI diagnosis for malignant tumors are made possible by direct comparison to the results obtained by the brain and it seems possible to differentiate malignant tumors from other benign lesions. Cystic lesions, and mycotic sinusitis sometimes resemble malignant tumors in MR Image. In the present report, we investigated the relationships between the biochemical contents of cystic lesions and NMR-parameters to clarify why some inflammatory lesions appeared similar to malignant tumors in MRI. The variation of relaxation time depends upon the amount of protein in the cystic contents and the amount of glucose affects the relaxation time. We conclude that NMR-parameters are useful for the differential diagnosis of malignant tumors, cystic lesions and mycositic sinusitis by using the multiple variation analysis.

1987-07-01

200

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of ...

2006-06-01

201

Fetal MRI of pathological brain development  

International Nuclear Information System (INIS)

Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)

2006-02-01

202

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

203

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

204

Low field magnetic resonance imaging of femoral neck fractures  

International Nuclear Information System (INIS)

Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).

205

PAS Domain Residues Involved in Signal Transduction by the Aer Redox Sensor of Escherichia coli  

UK PubMed Central (United Kingdom)

SummaryPAS domains sense oxygen, redox potential and light, and are implicated in behavior, circadian rhythmicity, development and metabolic regulation. Although PAS domains are...Full Text Available

2000-05-01

206

Genome-wide profiling of forum domains in Drosophila melanogaster  

UK PubMed Central (United Kingdom)

Forum domains are stretches of chromosomal DNA that are excised from eukaryotic chromosomes during their spontaneous non-random fragmentation. Most forum domains are 50–200 kb in length....Full Text Available

2011-05-01

207

A hypothetical model for the peptide binding domain of hsp70 based on the peptide binding domain of HLA.  

UK PubMed Central (United Kingdom)

The sequences of the peptide binding domains of 33 70 kd heat shock proteins (hsp70) have been aligned and a consensus secondary structure has been deduced. Individual members showed no significant...Full Text Available

1991-05-01

208

TIME EVOLUTION OF CORONAL MAGNETIC HELICITY IN THE FLARING ACTIVE REGION NOAA 10930  

International Nuclear Information System (INIS)

To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through ...

2010-09-10

209

Molecular accessibility in solvent swelled coal. Quarterly report  

Energy Technology Data Exchange (ETDEWEB)

To expand the information base on molecular accessibility in solvent swelled coal, Argonne Premium Coal Samples (APCS) were swelled in polar, basic solvents before and after moisture loss and upon air oxidation. So far studies have been reported on the changes in pore size distribution as a function of temperature when polar basic swelling solvents are used. Additional studies employing EPR spin probe techniques performed on the breaking up of the hydrogen bonding between bedding planes were later confirmed by magnetic resonance imaging at Argonne National Lab and the University of Illinois.

1992-11-01

210

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

211

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.  

Science.gov (United States)

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737

2006-12-19

213

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and ...

2011-09-01

214

Some proposed relations among the domains of behavior analysis  

UK PubMed Central (United Kingdom)

The present article examines the nature of and relations among the domains of behavior analysis. It first proposes a set of annotated, descriptive criteria to aid in distinguishing the experimental...Full Text Available

2003-01-01

215

Collaborative systems and multiagent systems  

CERN Document Server

This paper presents some basic elements regarding the domain of the collaborative systems, a domain of maximum actuality and also the multiagent systems, developed as a result of a sound study on the one-agent systems.

2009-01-01

216

T{sub 1} and T{sub 2} relaxivities of succimer-coated MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

Energy Technology Data Exchange (ETDEWEB)

Superparamagnetic MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r{sub 2}/r{sub 1}, for MnFe{sub 2}O{sub 4}, Fe{sub 3}O{sub 4} and CoFe{sub 2}O{sub 4} were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T{sub 2} contrast agents for MRI.

2009-12-15

217

T1 and T2 relaxivities of succimer-coated MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

International Nuclear Information System (INIS)

Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.

2009-12-01

218

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

Energy Technology Data Exchange (ETDEWEB)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the ...

2005-04-01

219

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

International Nuclear Information System (INIS)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the ...

2005-04-01

220

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

221

Cold SQUIDs and hot samples  

Energy Technology Data Exchange (ETDEWEB)

Low transition temperature (low-{Tc}) and high-{Tc} Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-{Tc} superconductors using two low-{Tc} SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise sources, suggesting that the vortices moved as rigid rods. At other ...

1997-05-01

222

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series ...

1999-10-01

223

High-field MR imaging in the follow-up of patients with valvular and composite tubular aortic prostheses  

International Nuclear Information System (INIS)

Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, MRI revealed pseudo-aneurysms (including a thrombosed one) at the ...

224

Pituitary disease in childhood: utility of magnetic resonance; Patologia hipofisaria en la edad pediatrica: unidad de la resonance magnetica  

Energy Technology Data Exchange (ETDEWEB)

To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural ...

2000-07-01

225

Magnetic Resonance Perfusion Imaging in Malformations of Cortical Development  

International Nuclear Information System (INIS)

Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side (rCBVRTSC and TTFMTSC) as well as those of ...

2007-10-01

226

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted ...

1991-01-01

227

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. ...

2001-03-01

228

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der ...

1994-12-31

229

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. ...

230

Determination of left ventricular ejection fraction and wall thickness in magnetic resonance imaging at 1.0 Tesla in comparison to echocardiography and biplanar ventriculography  

International Nuclear Information System (INIS)

We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ventriculography (4.5%#+-#10.1). MRI (1.0 T) accurately measures ...

231

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and cerebello-pontine angle. HRCT ...

2003-03-01

232

Nuclear resonant spectroscopy at Bragg reflections from periodic multilayers: Basic effects and applications  

Science.gov (United States)

A systematic study of the Bragg nuclear resonant reflectivity from periodic multilayers in the energy and time domains is presented. Using the kinematical approach of the general reflectivity theory we describe the basic features of the time evolution of the reflected wave after a pulsed excitation of resonant multilayers by synchrotron radiation. Effects of the collective excitation have been examined such as the shift of quantum beat phases, the interplay between electronic and nuclear subsystem excitations depending on their relative position in a multilayer, the energy and time evolution of standing waves inside a resonant multilayer, and their influence on the reflectivity spectra. The exact expression for the reflectivity by a thin resonant layer placed inside a multilayer structure has been derived. The observed shift of the delayed reflectivity Bragg peak relative to the prompt peak is explained by the developed formalism. Experimental applications are ...

2005-09-15

233

Chapter 14: Seismic imaging using 2- and 3-D migration  

Energy Technology Data Exchange (ETDEWEB)

Development of a number of original 3-D migration methods and algorithms is described. The computational efficiency of these algorithms is demonstrated by implementing them on vector and parallel supercomputers. Two-dimensional post-stack and pre-stack depth migration algorithms in the frequency - space domain using implicit finite difference method were also developed and implemented on a parallel computer, and adapted for applications that range from deep crustal imaging of seismic wavefields that involve wide ranging travel times and frequencies. All implicit finite difference migration algorithms were highly prallelized . The one pass 3-D post-stack depth migration algorithm was extensively used for imaging of seismic monitoring data from Cold Lake, Alberta. Experience shows that it provides the right trade-off between accuracy and computational efficiency. A new formulation of the 3-D reverse-time migration method was ...

1999-09-01

234

Nodular fasciitis: correlation of MRI findings and histopathology  

Energy Technology Data Exchange (ETDEWEB)

Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had homogeneous enhancement. One cellular lesion ...

2002-03-01

235

Numerical study of the impingement of a supersonic, axisymmetric jet on a flat plate  

International Nuclear Information System (INIS)

A numerical method for studying the flow field of an under-expanded axis-symmetric jet created by a converging-diverging nozzle and impinging on a flat plate is presented. The calculation domain of interest is a region that contains all the features of the jet that leaves the nozzle and impinges onto the plate. Axial symmetry of the domain allows a reduced 2-dimensional model to be used. FLUENT software is utilized to solve the continuity, momentum and energy equations using a coupled implicit scheme. The ideal-gas law is used to determine the gas density along with a k-#epsilon# turbulence model with a special modification to account for compressibility effects. In addition, the temperature dependency of viscosity has been taken into consideration. A number of different modeling techniques are investigated including different approximations to account for the flow inside the nozzle. Performance of non-equilibrium wall functions for near-wall ...

236

Development of an efficient parallel FEM analysis program for large structural problems over several millions of DOF  

International Nuclear Information System (INIS)

In order to predict or to evaluate the structural reliability of a variety of nuclear components under actual changing operating conditions, it is necessary to take the detailed geometrical features of components into consideration on one hand, and thermo-mechanical loading conditions with space and time variations during the lifetime, on the other hand. This consideration leads the authors to develop a super large-scale structural analysis program based on a parallel computational FEM with a variable scale of PC cluster architecture, whose prototype system is presented in a companion paper in this Symposium. Development of the PC cluster technology is one of the most important subjects in large-scale structural simulation, reducing computer costs and thus making simulation more acceptable to the engineering community. This paper presents the developmental status of the parallel FEM solver, demonstrating computational capabilities with three dimensional effects taking into ...

2000-09-01

237

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which ...

1998-05-01

241

SnPc on Ag(111) investigated by STM  

Energy Technology Data Exchange (ETDEWEB)

The investigation of interfaces between thin organic films and metal surfaces is a field of highest interest because it represents the basis for future applications of organic electronic devices. In this context, phtalocyanines are of particular interest since repulsive intermolecular interaction was found recently for this group of organic molecules. Tin(II)-phtalocyanine (SnPc) is non-planar and can adsorb in two different geometries: with the Sn atom pointing downwards (Sn down) or upwards (Sn up). In our group different Pc molecules have previously been studied using several experimental techniques like SPA-LEED or XSW. Here we present STM studies of SnPc on Ag(111), taken at different coverages and temperatures, and discuss the results in the context of our previous findings. At low coverages the formation of chains can be observed for Sn down molecules while Sn up molecules tend to stay separated. This originates from a strong interaction with the substrate which leads to a ...

2010-07-01

242

Reduction of nitrogen oxides (NO{sub x}) production in a liquid fuel-oil diffusion flame by acoustic excitation; Reduction de la production des oxydes d`azote (NO{sub x}) dans une flamme de diffusion a fioul liquide par excitation acoustique  

Energy Technology Data Exchange (ETDEWEB)

The control of nitrogen oxides (NO{sub x}) emissions will become a major challenge in the forthcoming years, in the domain of automotive industry or industrial burners. Pulsed combustion offers an imaginative solution which does not affect the combustion efficiency. In this paper, the efficiency of this method is demonstrated using the burner of a 20 kW domestic boiler. The actuator is simply installed on the air intake. Two types of actuators have been tested successfully: a loudspeaker and a rotative valve. Both can produce 100 to 1000 Hz frequencies and can lead to a reduction of 20% of NO{sub x} emissions. The feasibility of the concept is also demonstrated on a 840 kW liquid fuel-oil burner. The mechanisms involved during an excitation are explained using the CH{sup *} radical imaging. Results show an important reorganization of the flow and of the flame structure. During each excitation cycle, an annular swirl occurs at the leading edge ...

1996-12-31

243

Nanoheterostructure Cation Exchange: Anionic Framework Conservation  

Energy Technology Data Exchange (ETDEWEB)

In ionic nanocrystals the cationic sub-lattice can be replaced with a different metal ion via a fast, simple, and reversible place-exchange, allowing post-synthetic modification of the composition of the nanocrystal, while preserving its size and shape. Here, we demonstrate for the first time that during such an exchange, the anionic framework of the crystal is preserved. When applied to nanoheterostructures, this phenomenon ensures that compositional interfaces within the heterostructure are conserved throughout the transformation. For instance, a morphology composed of a CdSe nanocrystal embedded in a CdS rod (CdSe/CdS) was exchanged to a PbSe/PbS nanorod via a Cu2Se/Cu2S structure. During every exchange cycle, the seed size and position within the nanorod were preserved, as evident by excitonic features, Z-contrast imaging, and elemental line-scans. Anionic framework conservation extends the domain of cation exchange to the design of more ...

2010-05-11

244

Gravitational Waves from Collapsing Domain Walls  

CERN Document Server

We study the production of gravitational waves from cosmic domain walls created during phase transition in the early universe. We investigate the process of formation and evolution of domain walls by running three dimensional lattice simulations. If we introduce an approximate discrete symmetry, walls become metastable and finally disappear. We calculate the spectrum of gravitational waves produced by collapsing metastable domain walls. Extrapolating the numerical results, we find the signal of gravitational waves produced by domain walls whose energy scale is around 10^10-10^12GeV will be observable in the next generation gravitational wave interferometers.

2010-01-01

245

A study on the relation between linguistics-oriented and domain-specific semantics  

CERN Document Server

In this paper we dealt with the comparison and linking between lexical resources with domain knowledge provided by ontologies. It is one of the issues for the combination of the Semantic Web Ontologies and Text Mining. We investigated the relations between the linguistics oriented and domain-specific semantics, by associating the GO biological process concepts to the FrameNet semantic frames. The result shows the gaps between the linguistics-oriented and domain-specific semantics on the classification of events and the grouping of target words. The result provides valuable information for the improvement of domain ontologies supporting for text mining systems. And also, it will result in benefits to language understanding technology.

2010-01-01

246

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

247

Vector Velocity Imaging Using Cross-Correlation and Virtual Sources  

DEFF Research Database (Denmark)

Previous investigations have shown promising results in using the directional cross-correlation method to estimate velocity vectors. The velocity vector estimate provides information on both velocity direction and magnitude. The direction is estimated by beamforming signals along directions in the range $[0^{\\circ}; 180^{\\circ}[$ and identifying the direction that produces the largest correlation across emissions. An estimate of the velocity magnitude is obtained from the spatial shift between signals beamformed along the estimated direction. This paper expands these investigations to include estimations of the vector velocities of a larger region by combining the estimations along several scan lines. In combination with a B-mode image, the vector velocities are displayed as an image of the investigated region with a color indicating the magnitude, and arrows showing the direction of the flow. Using the RASMUS experimental ultrasound scanner, ...

2006-01-01

248

Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, ...

2009-03-01

249

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. ...

2005-09-01

250

MR imaging study on external hydrocephalus in infants: extracerebral space developmental and pathological enlargement  

International Nuclear Information System (INIS)

Objective: To analyze the characteristics of external hydrocephalus in infancy with MR imaging, and to explore the cause of accumulation of extracerebral fluid and the relation with brain development. Methods: Conventional magnetic resonance T_1 weighted imaging (T_1WI) and T_2 weighted imaging (T_2WI) were performed in 46 infants aged 2 years or younger with external hydrocephalus (EH), and the results were analyzed. They were divided into 7 age groups. The width of extractable space was measured on T_2WI and compared with normal standard. Results: EH mainly resulted from infection, subdural hematoma or subarachnoid hemorrhage, HIE, which were 67.4% (31/46 cases) of the cases; EH with unknown cause were 26.1% (12/46 cases). EH was mainly located at the foreside of cerebral convexity, of which 80.4% (37/46 cases )was predominantly in the subarachnoid space, 8.7% (4/46 cases) in subdural space, 10.9% was ...

2006-05-01

251

Magnetic Levitation of MC3T3 Osteoblast Cells as a Ground-Based Simulation of Microgravity  

UK PubMed Central (United Kingdom)

Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available

2009-11-01

252

Menstrual variation of breast volume and T{sub 2} relaxation times in cyclical mastalgia  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Hormonal activity causes breast volume to change during the menstrual cycle. One possible cause of this volume change is thought to be due to water retention or oedema within the tissues. We used magnetic resonance imaging (MRI) to study the variation in breast volume and {sup 1}H Magnetic Resonance Spectroscopy (MRS) to measure T{sub 2} relaxation times which are known to increase with increasing tissue water content. We hypothesised that an increase in breast volume will elevate T{sub 2} relaxation due to the presence of an increased water content within the breast. T{sub 2} Relaxation time and volume were studied in fifteen control subjects and in a cohort of eight patients with cyclical mastalgia in order to determine whether changes in breast volume and T{sub 2} relaxation times differed in controls and patients during menses, ovulation and premenses. Method: Breast volume was determined by the Cavalieri ...

2008-02-15

253

Refining the Magnetic Forming Capability.  

Science.gov (United States)

... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...

1972-04-01

255

BIOMAGNETIC RESPONSE OF SIMPLE BIOLOGICAL ...  

Science.gov (United States)

... Examples include magnetic forming tools, magnetic shielding, magnetohydrodynamic propulsion systems, and various magnetic containment ...

1970-01-01

256

/22k : - NASA Technical Reports Server  

Science.gov (United States)

in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...

257

The magnetic spectrometer PAMELA for the study of cosmic antimatter in space  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.

1995-09-01

258

Observing Evolution in the Supergranular Length Scale During Periods of Low Solar Activity  

CERN Document Server

We present the initial results of an observational study into the variation of the dominant length-scale of quiet solar emission: supergranulation. This length-scale reflects the radiative energy in the plasma of the upper solar chromosphere and transition region at the magnetic network boundaries forming as a result of the relentless interaction of magnetic fields and convective motions of the Sun's interior. We demonstrate that a net difference of ~0.5Mm in the supergranular emission length-scale occurs when comparing observations cycle 22/23 and cycle 23/24 minima. This variation in scale is reproduced in the datasets of multiple space- and ground-based instruments and using different diagnostic measures. By means of extension, we consider the variation of the supergranular length-scale over multiple solar minima by analyzing a subset of the Mt Wilson Solar Observatory (MWO) Ca II K image record. The observations and ...

2011-01-01

259

Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)  

International Nuclear Information System (INIS)

Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They certainly indicate early ...

260

Changes of magnetization transfer ratio according to rat brain development  

International Nuclear Information System (INIS)

We assessed the age-related changes in magnetization transfer ratio (MTR) value and the ratio of water content in rat brain (frontal lobe and pons) during normal development. All studies were done on 42 normal Wistar rats. MTR was calculated by using the equation (M_o_f_f-M_o_n)/M_o_f_f, where M_o_f_f and M_o_n were the measured signal intensities on the conventional and MT-prepared SPGR images, respectively. The ratios of water content were measured by comparing the wet weight with the dry weight of the frontal lobe and the pons, which were extracted from a rat brain soon after MTR measurements. The ratio of water content was calculated by using the equation 100 x (wet weight-dry weight)/wet weight (%). The ratio of water content decreased markedly during the first 30 days, but the decrease was very slight there after both in the frontal lobe and the pons. The change in MTR was similar to that of the ratio of water content, though the ...

261

Assembly of Linear Nano-Chains from Iron Oxide Nanospheres with Asymmetric Surface Chemistry  

Science.gov (United States)

Besides the multifunctionality, another equally important aspect of nanoparticles is their engineerability to control the geometrical and chemical properties during fabrication. In this work, we exploited this aspect to define asymmetric surface chemistry of an iron oxide nanosphere by controlling the topology of ligand expression on its surface resulting in a particle with two faces, one displaying only amines and the other only thiols. Specifically, amine-functionalized iron oxide nanospheres were attached on a solid support via a crosslinker containing a disulfide bridge. Liberation of the nanosphere using thiolytic cleavage created thiols on the portion of the particle's surface that interacted with the solid support. Employing a solid-phase strategy and a step-by-step addition of particles, the two unique faces on the same nanosphere served as fittings to assemble them into linear nano-chains. Assembly of chains with various lengths and aspect ratios was controlled by the size and ...

2011-01-06

262

The influence of normal human ageing on automatic movements  

British Library Electronic Table of Contents (United Kingdom)

There is evidence that aged normal subjects have more difficulty in achieving automaticity than young subjects. The underlying central neural mechanism for this phenomenon is unclear. In the present study, functional magnetic resonance imaging (fMRI) was used to investigate the effect of normal ageing on automaticity. Aged healthy subjects were asked to practice self-initiated, self-paced, memorized sequential finger movements with different complexity until they could perform the tasks automatically. Automaticity was evaluated by having subjects perform a secondary task simultaneously with the sequential movements. Although it took more time, most aged subjects eventually performed the tasks automatically at the same level as the young subjects. Functional MRI results showed that, for bot...

2005-01-01

263

Steady particulate flows in a horizontal rotating cylinder  

Energy Technology Data Exchange (ETDEWEB)

Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRI) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio {approximately}7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity field in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit. {copyright} {ital 1998 American Institute of Physics.}

1998-06-01

264

Primary and multisensory cortical activity is correlated with audiovisual percepts  

British Library Electronic Table of Contents (United Kingdom)

Incongruent auditory and visual stimuli can elicit audiovisual illusions such as the McGurk effect where visual /ka/ and auditory /pa/ fuse into another percept such as/ta/. In the present study, human brain activity was measured with adaptation functional magnetic resonance imaging to investigate which brain areas support such audiovisual illusions. Subjects viewed trains of four movies beginning with three congruent /pa/ stimuli to induce adaptation. The fourth stimulus could be (i) another congruent /pa/, (ii) a congruent /ka/, (iii) an incongruent stimulus that evokes the McGurk effect in susceptible individuals (lips /ka/ voice /pa/), or (iv) the converse combination that does not cause the McGurk effect (lips /pa/ voice/ ka/). This paradigm was predicted to show increased release fro...

2010-01-01

265

Mapping subcortical diffusivity. Application to brain development. Presidential award proceeding  

International Nuclear Information System (INIS)

We studied age-related microstructural changes in the subcortical white matter from adolescence to middle age in 16 healthy male subjects (age range: 12 to 47 years) using diffusion-weighted magnetic resonance (MR) imaging (DWI). Mean diffusivity (MD) of subcortical white matter was mapped onto the overlying cortical surface using our original method. The mean MD values within 76 cortical regions were measured using atlas-based gray matter segmentation and then correlated with age. A significant negative correlation with age was observed in subcortical MD values in several cortical regions, primarily over the bilateral temporal and occipital lobes. Our results demonstrated subcortical microstructural change in postadolescence that may reflect continuing myelination. (author)

2007-01-01

266

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

267

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

268

Influence of attention focus on neural activity in the human spinal cord during thermal sensory stimulation  

British Library Electronic Table of Contents (United Kingdom)

Perceptions of sensation and pain in healthy people are believed to be the net result of sensory input and descending modulation from brainstem and cortical regions depending on emotional and cognitive factors. Here, the influence of attention on neural activity in the spinal cord during thermal sensory stimulation of the hand was investigated with functional magnetic resonance imaging by systematically varying the participants' attention focus across and within repeated studies. Attention states included (1) attention to the stimulus by rating the sensation and (2) attention away from the stimulus by performing various mental tasks of watching a movie and identifying characters, detecting the direction of coherently moving dots within a randomly moving visual field and answering mentally-...

2011-01-01

269

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may be employed to ...

1991-10-02

270

Episodic Future Thinking Reduces Reward Delay Discounting through an Enhancement of Prefrontal-Mediotemporal Interactions  

British Library Electronic Table of Contents (United Kingdom)

Summary Humans discount the value of future rewards over time. Here we show using functional magnetic resonance imaging (fMRI) and neural coupling analyses that episodic future thinking reduces the rate of delay discounting through a modulation of neural decision-making and episodic future thinking networks. In addition to a standard control condition, real subject-specific episodic event cues were presented during a delay discounting task. Spontaneous episodic imagery during cue processing predicted how much subjects changed their preferences toward more future-minded choice behavior. Neural valuation signals in the anterior cingulate cortex and functional coupling of this region with hippocampus and amygdala predicted the degree to which future thinking modulated individual preference fu...

2010-01-01

271

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

272

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

273

Early diagnosis of skeletal disorders in childhood and adolescence by MRI; Fruehdiagnose orthopaedischer Erkrankungen des Kindes- und Jugendalters mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)

1998-09-18

274

Brain tumor in childhood. Hjernesvulst hos barn  

Energy Technology Data Exchange (ETDEWEB)

Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.

1990-05-01

275

Biopolymer system for permeability modification in porous media  

Energy Technology Data Exchange (ETDEWEB)

New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were ...

1995-12-31

276

Visualization and volumetric structures from MR images of the brain  

Energy Technology Data Exchange (ETDEWEB)

Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet ...

1994-03-01

277

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After ...

278

Normal and abnormal water diffusion in the brain  

International Nuclear Information System (INIS)

Diffusion magnetic resonance imaging (MRI) has become an important tool in the radiologic diagnosis of diseases of the brain as it measures molecular motion of water that characterizes the microstructure of tissues. Its most important clinical use to date is the early detection of cerebral ischemia by revealing the ischemic injury shortly after vessel occlusion and simultaneously providing therapy-relevant information on the tissue at risk. Furthermore, diffusion MRI is diagnostically promising in other diseases of the brain and is thus increasingly becoming part of routine clinical protocols in the diagnosis of tumors, inflammation, trauma, demyelination, dysmyelination and neurodegeneration. Although abnormalities of diffusion are generally not pathognomonic, diffusion MRI affords information about tissue changes for specific disorders that complements information obtained with standard MR techniques and frequently shows pathology earlier. In ...

2003-10-01

279

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI ...

2000-05-01

280

Diagnostic difficulties in extraosseous Ewing's sarcoma: A proposal for diagnostic criteria  

International Nuclear Information System (INIS)

Five cases diagnosed as extraosseous Ewing's sarcoma (EES) during a 15 year period, and the relevant literature, were reviewed. The diagnosis in these cases was difficult to confirm, mainly because the distinction between the osseous form of Ewing's sarcoma (OES) and either periosteal reactions or direct tumour invasion into adjacent bone by EES was often unclear. The literature suggests that other authors have also encountered difficulties. The authors believe that many cases reported as EES are likely to have been OES. This distinction has some importance, as the two conditions are usually treated in differing ways. The following criteria are proposed for the diagnosis of primary EES: (i) no evidence of bony involvement on magnetic resonance imaging; (ii) no evidence of increased uptake in bone or periosteum adjacent to the tumour on static isotope bone scan images; (iii) a small round cell tumour with no differentiating ...

281

Diagnosis of breast cancer with MR imaging using the magnetization transfer contrast and a newly-developed breast surface coil for the supine position  

Energy Technology Data Exchange (ETDEWEB)

We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation (CE+)) methods and the lesions using the SPGR (CE+) method after ...

1998-09-01

282

An availability of brain magnetic resonance imaging (MRI) in the early diagnosis of latent hepatic encephalopathy  

Energy Technology Data Exchange (ETDEWEB)

Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An improvement of this MRI finding was not observed by long-term oral ...

1996-03-01

283

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it ...

1998-02-01

284

Functional domain analysis of glass, a zinc-finger-containing transcription factor in Drosophila.  

Science.gov (United States)

The glass gene is required for proper photo-receptor differentiation during development of the Drosophila eye glass codes for a DNA-binding protein containing five zinc fingers that we show is a transcriptional activator. A comparison of the sequences of the glass genes from two species of Drosophila and a detailed functional domain analysis of the Drosophila melanogaster glass gene reveal that both the DNA-binding domain and the transcriptional-activation domain are highly conserved between the two species. Analysis of the DNA-binding domain of glass indicates that the three carboxyl-terminal zinc fingers alone are necessary and sufficient for DNA binding. We also show that a deletion mutant of glass containing only the DNA-binding domain can behave in a dominant-negative manner both in vivo and in a cell culture assay that measures transcriptional activation. PMID:7604032

1995-07-01

285

Preliminary studies of tunnel interface response modeling using test data from underground storage facilities.  

Energy Technology Data Exchange (ETDEWEB)

In attempting to detect and map out underground facilities, whether they be large-scale hardened deeply-buried targets (HDBT's) or small-scale tunnels for clandestine border or perimeter crossing, seismic imaging using reflections from the tunnel interface has been seen as one of the better ways to both detect and delineate tunnels from the surface. The large seismic impedance contrast at the tunnel/rock boundary should provide a strong, distinguishable seismic response, but in practice, such strong indicators are often lacking. One explanation for the lack of a good seismic reflection at such a strong contrast boundary is that the damage caused by the tunneling itself creates a zone of altered seismic properties that significantly changes the nature of this boundary. This report examines existing geomechanical data that define the extent of an excavation damage zone around underground tunnels, and the potential impact on rock properties such as P-wave and ...

2010-11-01

286

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto ...

2004-12-01

287

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for ...

2006-04-15

288

Monitoring the effect of chemotherapy in Ewing's sarcoma of bone with MR imaging  

International Nuclear Information System (INIS)

Magnetic resonance (MR) imaging was performed in 26 patients with Ewing's sarcoma of bone preceding and following neoadjuvant chemotherapy, to assess tumour response non-invasively prior to surgery. T1- and T2-weighted spin echo images were obtained. Changes including intra- and extramedullary signal intensities, tumour demarcation, tumour volume and the appearance of residual extramedullary tumour were compared with histophathology of the resected specimens. Reduction of tumour volume was significantly higher in good responders. Other single parameters did not correlated with histologic tumour response. However, when several MR parameters summarized in a classification system were combined, a positive correlation with histopathologic response was found. A limited decrease of tumour volume (<25 %) and/or residual soft tissue mass following chemotherapy correlated with a poor response. An inhomogeneous, well-defined cuff ...

289

Specification of the steel sheet for the 300 GeV magnet system  

CERN Document Server

Specification of the steel sheet for the 300 GeV magnet system

1971-01-01

290

Radial Halbach Magnetic Bearings  

Science.gov (United States)

Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly

2009-01-01

291

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

292

Magnetic forming of resistive materials  

Science.gov (United States)

Necessary theoretical foundation is given for the treatment of magnetic stresses applied to

1969-01-01

293

Magnetic forming coil design and development summary report  

Science.gov (United States)

Magnetic forming coil design and development

1964-01-01

295

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

296

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

298

Optical Images Due to Lenses and Mirrors  

Science.gov (United States)

... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...

299
300

The human peripheral subunit-binding domain folds rapidly while overcoming repulsive Coulomb forces  

UK PubMed Central (United Kingdom)

Peripheral subunit binding domains (PSBDs) are integral parts of large multienzyme complexes involved in carbohydrate metabolism. PSBDs facilitate shuttling of prosthetic groups between different catalytic...Full Text Available

2010-09-01

301

Structure of the Taz2 domain of p300: insights into ligand binding  

UK PubMed Central (United Kingdom)

CBP and its paralog p300 are histone acetyl transferases that regulate gene expression by interacting with multiple transcription factors via specialized domains. The structure...Full Text Available

2009-12-01

302

Structural formulae for some classes of analytic functions in a finitely connected domain  

Science.gov (United States)

Several central results of the method of structural formulae for some classes of analytic functions, which were known before for a disc and an annulus, are generalized to analytic functions in a finitely connected circular domain.

1997-12-01

303

Solution structure of two molecular motor domains: nonclaret disjunctional and kinesin.  

UK PubMed Central (United Kingdom)

The effects of selected ligands on the structure of the truncated heavy-chain chemomechanical motor domains of Drosophila ncd and human kinesin were compared using the technique of transient electric...Full Text Available

1995-04-01

304

ReplicationDomain: a visualization tool and comparative database for genome-wide replication timing data  

UK PubMed Central (United Kingdom)

BackgroundEukaryotic DNA replication is regulated at the level of large chromosomal domains (0.5–5 megabases in mammals) within which replicons are activated relatively synchronously....Full Text Available

305

Rearrangement of a common cellular DNA domain on chromosome 4 in human primary liver tumors.  

UK PubMed Central (United Kingdom)

Hepatitis B virus (HBV) DNA integration has been shown to occur frequently in human hepatocellular carcinomas. We have investigated whether common cellular DNA domains might be rearranged, possibly...Full Text Available

1988-02-01

306

Novel structural features in two ZHX homeodomains derived from a systematic study of single and multiple domains  

UK PubMed Central (United Kingdom)

BackgroundZhx1 to 3 (zinc-fingers and homeoboxes) form a set of paralogous genes encoding multi-domain proteins. ZHX proteins consist of two zinc fingers followed...Full Text Available

307

Initial Report of the Cancer PROMIS Supplement Sexual Function Committee: Review of Sexual Function Measures and Domains Used in Oncology  

UK PubMed Central (United Kingdom)

ObjectiveThis report describes initial activities of the Cancer Patient-Reported Outcomes Measurement Information System (PROMIS) Sexual Function domain group (CaPS-SF),...Full Text Available

2009-03-15

308

Fourth Order Accurate Discretization for the Laplace and Heat Equations on Arbitrary Domains, with Applications to the Stefan Problem.  

Science.gov (United States)

In this paper, the authors first describe a fourth order accurate finite difference discretization for both the Laplace equation and the heat equation with Dirichlet boundary conditions on irregular domains. In the case of the heat equation, they use an i...

2004-01-01

309

Dimeric subunit stoichiometry of the human voltage-dependent proton channel Hv1  

UK PubMed Central (United Kingdom)

In voltage-gated Na+, K+, and Ca2+ channels, four voltage-sensor domains operate on a central pore domain in response to membrane voltage. In contrast, the voltage-gated...Full Text Available

2008-06-03

310

Comparative Structural Analysis of Lipid Binding START Domains  

UK PubMed Central (United Kingdom)

BackgroundSteroidogenic acute regulatory (StAR) protein related lipid transfer (START) domains are small globular modules that form a cavity where lipids and lipid hormones bind....Full Text Available

311

Antibodies to synthetic peptides from the tubulin regulatory domain interact with tubulin and microtubules.  

UK PubMed Central (United Kingdom)

The carboxyl-terminal region of tubulin alpha and beta subunits plays a major role in regulating its assembly into microtubules and constitutes an essential domain for the selective interaction of microtubule-associated...Full Text Available

1988-09-01

312

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...

2009-03-01

313

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung  

Energy Technology Data Exchange (ETDEWEB)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...

2003-03-01

314

Application of photogrammetry, remote sensing and GIS in the environmental monitoring of the Deutsche Steinkohle AG; Einsatz von Photogrammetrie, Fernerkundung und GIS im Umweltmonitoring der Deutschen Steinkohle AG  

Energy Technology Data Exchange (ETDEWEB)

Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent scatterer technology (here: the use of the ...

2006-03-15

315

The Calculation and Measurement of Flexural and ...  

Science.gov (United States)

... Verheij (1980) described how the frequency domain could be exploited using cross spectral density measurements to measure the flexural ...

1996-02-01

317

Intelligent Analyst Digital Video Library Prototype  

Science.gov (United States)

... type. Sonic's digital libraries will provide a cross mapping between the narrative (speech and text) and imagery domains. ...

2002-10-01

318

Nuclear magnetic resonance spectroscopy in biomedicine. Course organized by the Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), September 18-23, 1995; Spettroscopia di risonanza magnetica nucleare in biomedicina. Corso organizzato dall`Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), 18-23 settembre 1995  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di condizioni imposto dalla ...

1997-12-01

319

Magnetic resonance imaging of stents. Quantitative in vitro examination at 3 Tesla; Magnetresonanztomographie von Stents. Quantitative MR-Untersuchungen in vitro bei 3 Tesla  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we calculated the apparent ...

2009-07-01

320

Hilar cholangiocarcinoma: MR correlation with surgical and histological findings  

International Nuclear Information System (INIS)

Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the ...

2010-10-01

321

Functional magnetic resonance imaging of the normal and abnormal visual system in early life.  

DEFF Research Database (Denmark)

Functional magnetic resonance imaging (fMRI) in young children may provide information about the development of the visual cortex, and may have predictive value for later visual performance. The purpose of this study was to evaluate the usefulness of fMRI for examining cerebral processing of vision in very young infants and in infants with brain damage. We examined 15 preterm infants, 12 children suspected of having a cerebral visual impairment and 10 children with a normal visual system, all of whom were either spontaneously asleep or sedated with chloral hydrate. Cortical response to stroboscopic light stimulation could be demonstrated in all technically acceptable data sets from children with a post-menstrual age (PMA) of > 41 weeks, but not in younger infants. Children < 60 weeks PMA showed either a blood oxygenation level-dependent (BOLD) signal increase or decrease, while all older children showed a signal decrease. The activated ...

2000-01-01

322

The YTH Domain Is a Novel RNA Binding Domain*  

UK PubMed Central (United Kingdom)

The YTH (YT521-B homology) domain was identified by sequence comparison and is found in 174 different proteins expressed in eukaryotes. It is characterized by 14 invariant residues within an α-helix/β-sheet...Full Text Available

2010-05-07

323

The Na+/H+ Exchanger NHE6 in the Endosomal Recycling System Is Involved in the Development of Apical Bile Canalicular Surface Domains in HepG2 Cells  

UK PubMed Central (United Kingdom)

Polarized epithelial cells develop and maintain distinct apical and basolateral surface domains despite a continuous flux of membranes between these domains. The Na+/H+exchanger...Full Text Available

2010-04-01

324

Structural Chemistry of Human SET Domain Protein Methyltransferases  

Science.gov (United States)

There are about fifty SET domain protein methyltransferases (PMTs) in the human genome, that transfer a methyl group from S-adenosyl-L-methionine (SAM) to substrate lysines on histone tails or other peptides. A number of structures in complex with cofactor, substrate, or inhibitors revealed the mechanisms of substrate recognition, methylation state specificity, and chemical inhibition. Based on these structures, we review the structural chemistry of SET domain PMTs, and propose general concepts towards the development of selective inhibitors.

2011-08-22

325

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently ...

2003-12-01

326

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.  

DEFF Research Database (Denmark)

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global stimulation, ...

2004-01-01

327

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and the variations in uniformity were unique ...

1984-06-05

330

Java Image I/O for VICAR, PDS, and ISIS  

Science.gov (United States)

This library, written in Java, supports input and output of images and metadata (labels) in the

2011-01-01

331

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can ...

2003-07-01

332

Magnetic resonance imaging of cerebral anomalies in subjects with resistance to thyroid hormone  

Energy Technology Data Exchange (ETDEWEB)

Resistance to thyroid hormone (RTH) is an autosomal dominant disease caused by mutations in the human thyroid receptor beta gene on chromosome 3. Individuals with RTH have an increased incidence of attention deficit hyperactivity disorder (ADHD). The purpose of this study was to search for developmental brain malformations associated with RTH. Forty-three subjects (20 affected males [AM], 23 affected females [AF]) with resistance to thyroid hormone and 32 unaffected first degree relatives (18 unaffected males [UM], 14 unaffected females [UF]) underwent MRI brain scans with a volumetric acquisition that provided 90 contiguous 2 mm thick sagittal images. Films of six contiguous images beginning at a standard sagittal position lateral to the insula were analyzed by an investigator who was blind with respect to subject characteristics. The presence of extra or missing gyri in the parietal bank of the Sylvian fissure (multimodal association cortex) ...

1995-06-19

333

Injuries of the tibio-talar joint and preoperative planning. Verletzungen des oberen Sprunggelenks aus unfallchirurgischer Sicht  

Energy Technology Data Exchange (ETDEWEB)

The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with ...

1991-12-01

334

Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy  

International Nuclear Information System (INIS)

High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 ...

2008-11-21

335

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal ...

2000-08-01

336

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...

1981-11-11

338

Magnetic braking of the rotation of molecular cloud cores  

International Nuclear Information System (INIS)

We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).

339

LHC magnet alignment  

CERN Document Server

Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.

2007-01-01

340

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

341

Density separation of materials by using magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...

1980-03-01

342

The low-frequency spectral behavior of cosmic ray intensity  

Energy Technology Data Exchange (ETDEWEB)

Power spectral analysis of cosmic ray intensity recorded by neutron monitors at Calgary and Deep River, Alberta, was carried out over a wide range of frequencies from 3 {times} 10{sup {minus}9} Hz to 6 {times} 10{sup {minus}6} Hz during the epoch 1965-1989 and revealed different behavior of the power spectral density for the three ranges of frequency domains. At low frequencies corresponding to the periodicity T {approx} 20 months the power spectrum shows an abrupt change in the level and profile of power spectral density (PSD). This indicates that the processes responsible for the long period variations are different from the one which causes short-period variations. At middle frequencies corresponding to periodicities between 6 and 18 months, the PSD indicates that the periodicities are not stable and show a transient character over the entire epochy of analysis. The PSD for periods T {approx} 27 days indicates an 11 year recurring tendency related to solar ...

1991-09-01

343

FORMATION EPOCHS, STAR FORMATION HISTORIES, AND SIZES OF MASSIVE EARLY-TYPE GALAXIES IN CLUSTER AND FIELD ENVIRONMENTS AT z = 1.2: INSIGHTS FROM THE REST-FRAME ULTRAVIOLET  

International Nuclear Information System (INIS)

We derive stellar masses, ages, and star formation histories (SFHs) of massive early-type galaxies in the z = 1.237 RDCS1252.9-2927 cluster and compare them with those measured in a similarly mass-selected sample of field contemporaries drawn from the Great Observatories Origin Deep Survey South Field. Robust estimates of these parameters are obtained by comparing a large grid of composite stellar population models with 8-9 band photometry in the rest-frame near-ultraviolet, optical, and IR, thus sampling the entire relevant domain of emission of the different stellar populations. Additionally, we present new, deep U-band photometry of both fields, giving access to the critical far-ultraviolet rest frame, in order to empirically constrain the dependence of the most recent star formation processes on the environment. We also analyze the morphological properties of both samples to examine the dependence of their scaling relations on their mass and environment. We ...

2010-01-20

344

Durability of cement-based materials: modeling of the influence of physical and chemical equilibria on the microstructure and the residual mechanical properties; Durabilite des materiaux cimentaires: modelisation de l'influence des equilibres physico-chimiques sur la microstructure et les proprietes mecaniques residuelles  

Energy Technology Data Exchange (ETDEWEB)

A large part of mechanical and durability characteristics of cement-based materials comes from the performances of the hydrated cement, cohesive matrix surrounding the granular skeleton. Experimental studies, in situ or in laboratory, associated to models, have notably enhanced knowledge on the cement material and led to adapted formulations to specific applications or particularly aggressive environments. Nevertheless, these models, developed for precise cases, do not permit to specifically conclude for other experimental conclusions. To extend its applicability domain, we propose a new evolutive approach, based on reactive transport expressed at the microstructure scale of the cement. In a general point of view, the evolution of the solid compounds of the cement matrix, by dissolutions or precipitations, during chemical aggressions can be related to the pore solution evolution, and this one relied to the ionic exchanges with the external environment. By the ...

2004-09-15

345

Physical and optical properties of rare earth cobalt magnets  

Energy Technology Data Exchange (ETDEWEB)

Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.

1980-08-01

347

METHOD OF FORMING THIN MAGNETIC FILM  

J-STORE (Japan)

Full Text Available

2007-10-04

349

NASA TECH BRIEF  

Science.gov (United States)

Magnetic Forming Studies. The use of transient high magnetic-field devices has made possible the generation of very large accurately ...

351

Magnetic properties of single crystalline RE_2PdSi_3 intermetallic compounds  

International Nuclear Information System (INIS)

... susceptibility magnetization magnetoresistance monocrystals order-disorder

352

Finite Element Analysis of Magnetoelastic Plate Problems.  

Science.gov (United States)

... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...

1981-08-01

353

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

354

An investigation of the decoupling effects in a magnetic forming beryllium coil assembly.  

Science.gov (United States)

Decoupling force exerted by magnetic forming Be coil assembly on metallic plate during forming

1968-01-01

355

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance ...

2000-12-01

356

Progress of magnetic-suspension systems and magnetic bearings in the USSR  

International Nuclear Information System (INIS)

This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.

1992-05-01

357

International Symposium on Magnetic Suspension Technology. Part 2  

International Nuclear Information System (INIS)

In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.

1991-08-19

358

View larger image for ISS022-E-26137 - Earth Sciences and Image ...  

Science.gov (United States)

The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...

359

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

360

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

361

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

362

3 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...

363

(Hadamard transform imaging)  

Science.gov (United States)

This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)

1990-01-01

364

Surgery for acoustic neurinoma treated by gamma-knife radiosurgery. A case report  

Energy Technology Data Exchange (ETDEWEB)

A 52-year-old woman had a history of left hearing loss for 5 years. An acoustic neurinoma with 3.2 cm in diameter was diagnosed and treated with gamma-knife radiosurgery (19 Gy of marginal dose) 1 year and 4 months ago. She developed headache, nausea, and visual disturbance 1 month prior to admission. Slight left facial palsy appeared after radiosurgery. Magnetic resonance imaging demonstrated the tumor with central necrosis in the left cerebellopontine angle cistern, increasing in size to 3.5 cm in diameter, and hydrocephalus. Tumor removal was performed incompletely, because of the fibrous appearance of the tumor and severe adherence with the surrounding cerebellar tissue. Facial palsy did not worsen after surgery. Since the hydrocephalus was not resolved, a right ventriculo-peritoneal shunt was inserted. The clinical course in this case suggests that tumor removal followed by radiosurgery was an approximately effective treatment for large ...

2001-08-01

365

Oil-shale Fischer assay analysis from selected coreholes in the Piceance Creek Basin, Colorado. Data file  

Energy Technology Data Exchange (ETDEWEB)

A magnetic tape consisting of oil-shale Fischer assay data for selected well cores in the Piceance Creek Basin was prepared as a supplement to NTIS tape PB-230 607/AS. Both tapes serve as a data base for calculating oil-shale resources (Pitman, 1981). The tape is in standard IBM format and has the following specifications: EBCDIC (IBM standard), card-image, blocksize 1720 (blocked 20 to 1), record length 86, odd parity, 1,600 bpi, 9-track, no label tape. Each data file on the tape consists of records containing oil-shale analyses for one well core. The first record in a data file consists of a well-core identifier which is a three-digit number preceded by the character 'C'. The second record contains the well name and location, and the remaining records contain Fischer assay data.

1981-01-01

366

Non-white noise in fMRI: does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2005-01-01

367

Non-white noise in fMRI: Does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...

2006-01-01

368

Multiple-element eddy current probes for enhanced inspection  

Energy Technology Data Exchange (ETDEWEB)

Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe design is multiple ...

1993-07-01

369

MRS of normal and impaired fetal brain development  

International Nuclear Information System (INIS)

Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are ...

2006-02-01

370

Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis.  

DEFF Research Database (Denmark)

The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly to both the results of the contrast sensitivity test ...

2002-01-01

371

Early effects of boron neutron capture therapy on rat glioma models  

International Nuclear Information System (INIS)

Early effects of boron neutron capture therapy (BNCT) on malignant glioma are characterized by reduction of the enhancement area and regression of the peritumoral edema radiologically. The aim of this study was to investigate the early histological changes of tumors and inflammatory cells after BNCT in the rat brain. Rats were treated with BNCT using boronophenylalanine (BPA) 7 days after implantation of C6 glioma cells. The tumors were assessed with magnetic resonance imaging and histopathological examination at 4 days after BNCT. The mean tumor volumes were 39#+-#2 mm"3 in the BNCT group and 134#+-#18 mm"3 in the control group. In the BNCT group, tumor cells showed a less pleomorphic appearance with atypical nuclei and mitotic figures. The Ki-67 labeling index was 6.5%#+-#4.7% in the BNCT and 35%#+-#3.8% in the control group. The reactions of the inflammatory cells were examined with ED-1 as macrophage marker and OX42 as microglia marker. ...

372

Calculating ac/dc resistance ratios for high-pressure oil-filled cable Designs. Volume 1. Designer's guide. Final report  

Energy Technology Data Exchange (ETDEWEB)

Using electromatic field theory, a new method is developed for calculating alternating current in power cables installed in pipes of carbon steel (magnetic pipes). The technique for evaluating these losses is based on the method of images which replaces complicated distribution of currents in the system with a sequence of thin conductors. The method not only gives a mathematical framework for the solution of alternating current losses, but it also gives the underlying physical picture of effects contributing to these losses. Skin effect, proximity effect and losses due to the pipe are calculated separately. For the first time, the increase of losses in the conductors, when the cables are placed in a magetic pipe, are analyzed mathematically. Good agreement is obtained between the result of calculations and the experimentally determined ac-dc resistance ratios for pipe-type cables with concentric stranded copper conductors and also for cables ...

1985-04-01

373

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of PVNS and tendinitis ...

1988-01-01

374

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...

1998-02-01

375

A new measurement of the antiproton-to-proton flux ratio up to 100 GeV in the cosmic radiation  

CERN Document Server

A new measurement of the cosmic ray antiproton-to-proton flux ratio between 1 and 100 GeV is presented. The results were obtained with the PAMELA experiment, which was launched into low-earth orbit on-board the Resurs-DK1 satellite on June 15th 2006. PAMELA is equipped with a silicon-microstrip magnetic spectrometer and a silicon-tungsten imaging calorimeter and has been collecting data since July 2006. During 500 days of data collection a total of about 1000 antiprotons have been identified, including 100 above an energy of 20 GeV. The high-energy results are a ten-fold improvement in statistics with respect to all previously published data. The antiproton-to-proton flux ratio increases smoothly with energy up to about 10 GeV, in agreement with previous experiments, and then levels off. The data follow the trend expected from secondary production calculations and significantly constrain contributions from exotic sources, e.g. dark matter ...

2008-01-01

376

UHRF1, a modular multi-domain protein, regulates replication-coupled crosstalk between DNA methylation and histone modifications  

Science.gov (United States)

Cytosine methylation in DNA is a major epigenetic signal, and plays a central role in propagating chromatin status during cell division. However the mechanistic links between DNA methylation and histone methylation are poorly understood. A multi-domain protein UHRF1 (ubiquitin-like, containing PHD and RING finger domains 1) is required for DNA CpG maintenance methylation at replication forks, and mouse UHRF1-null cells show enhanced susceptibility to DNA replication arrest and DNA damaging agents. Recent data demonstrated that the SET and RING associated (SRA) domain of UHRF1 binds hemimethylated CpG and flips 5-methylcytosine out of the DNA helix, whereas its tandom tudor domain and PHD domain bind the tail of histone H3 in a highly methylation sensitive manner. We hypothesize that UHRF1 brings the two components (histones and DNA) carrying appropriate markers (on the tails of H3 ...

2009-01-01

377

Time-domain dynamic opto-rheology study of polymer films using step-scan FTIR time-resolved spectroscopy (S{sup 2}FTIR TRS)  

Energy Technology Data Exchange (ETDEWEB)

Step-scan Fourier transform infrared spectroscopy in conjunction with impulse stress on polymer films has been used to monitor dynamic rheological responses in real time. A novel piezo-electrically-driven polymer microrheometer was employed to apply repetitive impulses to the polymer sample while time-domain spectra were recorded. Recent results include the study of both semi-crystalline polymers such as isotactic polypropylene (iPP) and elastomers such as Estane polyester/polyurethane copolymer and Kraton tri-block copolymer. The spectral changes of iPP are consistent with frequency-domain results. For iPP at room temperature, large differences in the response times of different absorption bands are not seen. However, the orientation response of the CH{sub 3} rocking mode is slightly slower than the responses of the backbone modes. To the authors` knowledge, this is the first reported successful step-scan FTIR time-domain ...

1998-07-01

378

Design of a magnetic braking system  

International Nuclear Information System (INIS)

A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted magnetic flux is within ...

2006-09-01

379

The influence of tertiary structural restraints on conformational transitions in superhelical DNA.  

UK PubMed Central (United Kingdom)

This paper examines theoretically the effects that restraints on the tertiary structure of a superhelical DNA domain exert on the energetics of linking and the onset of conformational transitions. The...Full Text Available

1987-12-10

380

Telomeres in cancer and ageing  

UK PubMed Central (United Kingdom)

Telomeres protect the chromosome ends from unscheduled DNA repair and degradation. Telomeres are heterochromatic domains composed of repetitive DNA (TTAGGG repeats) bound to an array of specialized...Full Text Available

2011-01-12

381

Research of time-domain equivalent circuit method in solving dispersion of coupled-cavity traveling-wave tube  

International Nuclear Information System (INIS)

In this paper, a time-domain equivalent circuit method is applied to solve dispersion of coupled-cavity travelling-wave tube (CCTWT). First, the time-domain circuit equations of CCTWT coupled-cavity chain are deduced from the equivalent circuit model. Then, the equations are solved numerically by fourth-order Runge-Kutta method and a program CTTDCP is developed using MATLAB. Last, a L-band CCTWT is calculated using CTTDCP and the cavity pass-band of this tube is computed to be 1.08-1.48 GHz, which is consistent with the experimental results and the simulation results of electromagnetic code and demonstrates the validity of the time-domain equivalent circuit method. In addition, a new design method which uses the equivalent circuit method and electromagnetic simulation together to optimize the cold cavity characteristics of CCTWT is proposed. (authors)

2008-09-01

382

Magnetohydrodynamic structure of a plasmoid in fast ... - NASA  

Science.gov (United States)

We set a symmetric boundary at x=200 and a conducting wall at z=150. The domain of 0200. 0150 is resolved by 60004500 grid cells. Harris sheet ...

383

Frequency-Domain Optical Mammogram  

Science.gov (United States)

... where i is the wavelength index (ranging from 1 to 4), while Esb and FHb02 are the molar extinction coefficients of deoxy-hemoglobin and oxy ...

2002-10-01

384

Fractional domain walls from on-site softening in dipolar bosons  

CERN Document Server

We study dipolar bosons in a 1D optical lattice and identify a region in parameter space---strong coupling but relatively weak on-site repulsion---hosting a series of stable CDW states whose low-energy excitations, built from "fractional domain walls", are remarkably similar to those of non-abelian fractional quantum Hall states. Here, a conventional domain wall between translated CDW's may split by inserting strings of degenerate, but inequivalent, CDW states. Outside these insulating regions, we find numerous supersolids as well as a superfluid regime. The mentioned phases should be accessible experimentally, and in particular, the fractional domain walls can be created in the ground state using single-site addressing, i.e. by locally changing the chemical potential.

2011-01-01

385

Characterization of radon penetration of different structural domains of concrete. Final project report  

International Nuclear Information System (INIS)

This report documents the research activities by Rogers and Associates Engineering Corporation on grant DE-FG03-93ER61600 during the funded project period from August 1993 to April 1996. The objective of this research was to characterize the mechanisms and rates of radon gas penetration of the different structural domains of the concrete components of residential floor slabs, walls, and associated joints and penetrations. The research was also to characterize the physical properties of the concretes in these domains to relate their radon resistance to their physical properties. These objectives support the broader goal of characterizing which, if any, concrete domains and associated properties constitute robust barriers to radon and which permit radon entry, either inherently or in ways that could be remediated or avoided.

386

Characterization of and Concepts for Metroplex Operations  

Science.gov (United States)

7.5.6 Conclusions of the Generic Metroplex Queueing Simulation . ...... the systemwide arrival delays incurred at the metroplex terminal-area ...... assignment rules, estimated nominal transit speeds or times by domain, and stochastic ...

387

Bayesian models for multiple outcomes nested in domains  

UK PubMed Central (United Kingdom)

SummaryWe consider the problem of estimating the effect of exposure on multiple continuous outcomes, when the outcomes are measured on different scales and are nested within multiple...Full Text Available

2009-12-01

389

Aeroelastic Analysis by Coupled Non-linear Time Domain ... - NASA  

Science.gov (United States)

and shock induced flow separation may significantly affect the flutter ...... Aerodynamic and Aeroelastic Simulation, AGARD Report 822, 10-1 10-20. ...

390
392

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

393
396

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

397

Image Engine: an object-oriented multimedia database for storing, retrieving and sharing medical images and text.  

UK PubMed Central (United Kingdom)

This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available

1993-01-01

402

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

403

Magnetic fluctuation measurement in Sino United Spherical Tokamak plasma  

International Nuclear Information System (INIS)

To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)

2007-07-01

404

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ...

2003-11-01

405

Patterns of ovarian morphology in polycystic ovary syndrome: a study utilising magnetic resonance imaging  

Energy Technology Data Exchange (ETDEWEB)

To evaluate and compare MRI-based ovarian morphology in groups of women with polycystic ovary syndrome (PCOS) and controls. All PCOS cases (n = 44) had oligo-amenorrhoea and hyperandrogenism irrespective of ovarian morphology, and fulfilled NIH/Rotterdam diagnostic criteria for PCOS. All control women (n = 40) had normal menses and normoandrogenaemia. All subjects were of white British/Irish origin and pre-menopausal. Group comparisons were based on independent-sample t tests. Polycystic ovarian morphology was defined by at least 12 follicles 2-9 mm in diameter and/or an ovarian volume greater than 10 cm{sup 3}. Ovarian morphology differed significantly in PCOS cases and controls (follicle number geometric mean [SD range] 18.6 [9.9, 35.0] vs 6.6 [3.1, 14.2], unadjusted P = 1.3 x 10{sup -16}; calculated ovarian volume 8.8 cm{sup 3} [5.0, 15.5] vs 5.1 cm{sup 3} [2.5, 10.3], unadjusted P = 3.0 x 10{sup -7}; peripheral follicle location in 55% vs 18% of ovaries, P = 7.9 x 10{sup -6}; ...

2010-05-15

406

Extension of adrenal tumors into the vena cava: results of magnetic resonance angiography; Kavazapfen bei Nebennierentumoren: Kernspintomographische Befunde  

Energy Technology Data Exchange (ETDEWEB)

In rare cases, large adrenal masses with a suspicion of malignancy exhibit tumor extension into the adrenal vein and inferior vena cava. When planning surgery, the relationship of the extension to the inferior vena cava is of decisive improtance. We describe in two cases on the detection of a tumor thrombus in the inferior vena cava arising from a malignant adrenal mass by means of MR angiography (TOF, coronary 2D GRE images [FLASH], 3 slices acquired during 15 second apnea). The angiograms correlated well with the results of DSA venacavography and with the intraoperative findings. Thus, MRA has been demonstrated to be suitable for the certain proof of a venous tumor thrombus not only in cases of renal cell carcinomas but also in cases of malignant adrenal masses. The method should be applied whenever there is evidence of a venous involvement in the adrenal MR images. (orig.) [Deutsch] Grosse malignomverdaechtige Nebennierentumoren zeigen in ...

1995-11-01

407

Diffusion and perfusion MR imaging in stroke; MR-Diffusion und -Perfusion beim Schlaganfall  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) in stroke makes it possible to visualize the initial infarct in cases of acute cerebral ischemia. Perfusion MRI serves to determine which tissues are additionally at risk of infarction due to persistent hypoperfusion. MRI also allows those examiners with limited experience to reliably confirm an infarct. The most important differential diagnosis of cerebral ischemia, intracerebral hemorrhage, can likewise be recognized with certainty using MRI. Although diffusion and perfusion MRI only demonstrate the pathophysiology of cerebral ischemia approximately, the method is suited for identifying those patients who would profit from reperfusion therapy. Whether MRI is also appropriate as an aid to reaching a prognosis on the risk of secondary hemorrhage has not yet been resolved. (orig.) [German] Die Schlaganfall-MRT ermoeglicht es, bei akuter zerebraler Ischaemie den bereits initial entstandenen Infarkt darzustellen. ...

2005-05-01

408

3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the intracranial ...

2004-11-01

409

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-15

410

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-01

411

Functional imaging of neurocognitive dysfunction in attention deficit hyperactivity disorder; Bildgebende Darstellung neurokognitiver Dysfunktionen bei der Aufmerksamkeitsdefizit-/Hyperaktivitaetsstoerung  

Energy Technology Data Exchange (ETDEWEB)

Attention Deficit Hyperactivity Disorder (ADHD) is a neurobiological disorder of early childhood onset. Defining symptoms are chronic impairments of attention, impulse control and motor hyperactivity that frequently persist until adulthood. Miscellaneous causes of the disorder have been discussed. Accumulating evidence from imaging- and molecular genetic studies strengthened the theory of ADHS being a predominantly inherited disorder of neurobiological origin. In the last 15 years, non-invasive brain imaging methods were successfully implemented in pediatric research. Functional magnetic resonance imaging studies gave major insight into the neurobiological correlates of executive malfunction, inhibitory deficits and psychomotoric soft signs. These findings are in good accordance with brain morphometric data indicating a significant volumetric decrease of major components of striato-thalamo-cortical ...

2005-02-01

412

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed ...

2002-05-01

413

Esters useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

1981-08-18

414

Esters useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

415

Amides useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula

1981-07-21

416

Amides useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.

417

Primary Ewing's sarcoma of the vertebral column  

International Nuclear Information System (INIS)

To determine the demographics, imaging findings, clinical symptoms, and prognosis of primary vertebral Ewing's sarcoma (PVES). A retrospective review of medical records and radiological studies of patients diagnosed with PVES from 1936 through 2001 in our institution and Department of Pathology consultation files was undertaken. Metastatic and soft tissue Ewing's sarcoma cases were excluded. From a total of 1,277 cases of Ewing's sarcoma, 125 (9.8%) had a primary vertebral origin. There were 48 females and 76 males. Patient ages ranged from 4 to 54 (mean 19.3, standard deviation 10.7, median 16) years. Vertebral column distribution was four cervical (3.2%), 13 thoracic (10.5%), 31 lumbar (25%), and 67 sacrum (53.2%). More than one vertebral segment was involved in ten cases (8%). Satisfactory imaging studies were available in 51 patients: 49 radiographs, 27 computerized tomography (CT), and 23 magnetic resonance ...

2004-09-01

418

In vitro investigation of biological and technical prosthetic heart valves in MRI: evaluation of possible deflection and heating of the implants; In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung moeglicher Anziehung und Erhitzung der Implantate  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: Patients with the tested ...

2000-02-01

419

Comparison of histological findings and parathyroid scintigraphy in hemodialysis patients with secondary hyperparathyroid glands  

International Nuclear Information System (INIS)

The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and ...

2005-04-01

420

Image-enhancement applications at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.

1982-06-01

421

Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...

1999-04-01

422

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

423

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...

2009-02-21

424

Magnetic properties of materials  

Energy Technology Data Exchange (ETDEWEB)

A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)

2000-08-15

425

Magnetic flocculation and filtration  

Energy Technology Data Exchange (ETDEWEB)

A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.

1996-10-01

426

Rin-like, a novel regulator of endocytosis, acts as guanine nucleotide exchange factor for Rab5a and Rab22  

UK PubMed Central (United Kingdom)

RIN proteins serve as guanine nucleotide exchange factors for Rab5a. They are characterized by the presence of a RIN homology domain and a C-terminal Vps9 domain. Currently three family members have...Full Text Available

2011-06-01

427

Numerical methods for determining the inhomogeneity boundary in a boundary value problem for Laplace?s equation in a piecewise homogeneous medium  

British Library Electronic Table of Contents (United Kingdom)

A boundary value problem for Laplace?s equation in a bounded two-dimensional domain filled with a piecewise homogeneous medium is considered. The boundary of the inhomogeneity is assumed to be unknown. The inverse problem of determining the inhomogeneity boundary and the solution of the equation given the solution and its normal derivative on the boundary of the domain is discussed. Numerical methods are proposed for solving the inverse problem, and the results of numerical experiments are presented.

2011-01-01

428

Mutations Affecting Motifs of Unknown Function in the Central Domain of Nitrogen Regulatory Protein C  

UK PubMed Central (United Kingdom)

The positive control function of the bacterial enhancer-binding protein NtrC resides in its central domain, which is highly conserved among activators of ς54 holoenzyme. Previous...Full Text Available

1999-09-01

429

Hepatitis C Virus RNA Replication Requires a Conserved Structural Motif within the Transmembrane Domain of the NS5B RNA-Dependent RNA Polymerase ?  

UK PubMed Central (United Kingdom)

Hepatitis C virus (HCV) nonstructural protein 5B (NS5B), the viral RNA-dependent RNA polymerase (RdRp), is a tail-anchored protein with a highly conserved C-terminal transmembrane domain (TMD) that...Full Text Available

2010-11-01

430

Cauchy problem for the Mathieu equation away from parametric resonance  

British Library Electronic Table of Contents (United Kingdom)

Four solutions of the Cauchy problem for Mathieu?s equation away from parametric resonance domains are analytically constructed using an asymptotic averaging method in the fourth approximation. Three solutions occur near fractional parameter values at which slow combination phases exist. The fourth solution occurs in the absence of slow phases away from parametric resonance domains and the fractional parameter values.

2011-01-01

431

An Effective Method of Image Retrieval using Image Mining Techniques  

CERN Document Server

The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...

2010-01-01

432

Lipid domain formation modulates activities of snake venom phospholipase A(2) enzymes.  

Science.gov (United States)

The goal of the present study is to elucidate the effect of lipid domain formation on activities of Naja naja atra and Bungarus multicinctus phospholipase A(2) (PLA(2)) enzymes. Sphingomyelin inhibited enzymatic activity and membrane-damaging activity of PLA(2) against egg yolk phosphatidylcholine (EYPC), while cholesterol and cholesterol sulfate abrogated the inhibitory effect of sphingomyelin. The ability of cholesterol and cholesterol sulfate to abolish the inhibitory effect of sphingomyelin was closely related to their capacity to induce domain formation in EYPC/sphingomyelin vesicles. Laurdan fluorescence measurement revealed that membrane packing of EYPC/sphingomyelin vesicles was differently affected by cholesterol and cholesterol sulfate. Unlike cholesterol, cholesterol sulfate was unable to promote domain formation in dipalmitoylphosphatidylcholine (DPPC) vesicles. Cholesterol increased but cholesterol sulfate ...

2010-08-10

433

Accident knowledge and emergency management  

Energy Technology Data Exchange (ETDEWEB)

The report contains an overall frame for transformation of knowledge and experience from risk analysis to emergency education. An accident model has been developed to describe the emergency situation. A key concept of this model is uncontrolled flow of energy (UFOE), essential elements are the state, location and movement of the energy (and mass). A UFOE can be considered as the driving force of an accident, e.g., an explosion, a fire, a release of heavy gases. As long as the energy is confined, i.e. the location and movement of the energy are under control, the situation is safe, but loss of confinement will create a hazardous situation that may develop into an accident. A domain model has been developed for representing accident and emergency scenarios occurring in society. The domain model uses three main categories: status, context and objectives. A domain is a group of activities with allied goals and elements and ten ...

1997-03-01

434

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...

2007-04-15

435

The effective longitudinal dielectric constant for plasmas in inhomogeneous magnetic fields  

Scientific Electronic Library Online (English)

Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.

2004-09-01

436

Magnetic mirror fusion systems: Characteristics and distinctive features  

Energy Technology Data Exchange (ETDEWEB)

A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.

1987-08-10

437

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

438

Magnetic excitations studied with time-of-flight spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.

1996-11-01

439

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

440

Active magnetic regenerator  

Energy Technology Data Exchange (ETDEWEB)

The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.

1982-01-01

441

Nanocrystalline permanent magnets with enhanced properties  

International Nuclear Information System (INIS)

Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

2001-09-23

442

Stent placement under real-time MR control: first experience in an animal model; Stentplazierung unter Echtzeit-MR-Kontrolle: erste tierexperimentalle Erfahrungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored ...

1998-12-01

443

Soft tissue manifestations of early rheumatic disease. Imaging with MRI; Fruehmanifestationen rheumatischer Gelenkerkrankungen an den Weichgewebestrukturen der Hand. Nachweis mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema ...

2006-08-15

444

Untitled - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...

445

Symptoms of the musculoskeletal system and exposure to magnetic fields in an aluminium plant.  

UK PubMed Central (United Kingdom)

OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available

1995-08-01

446

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be ...

2009-10-19

447

Possible observation of the coexistence of superconductivity and long-range magnetic order in NdRh_4B_4  

International Nuclear Information System (INIS)

The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).

1979-01-01

448

PLASMA JET WELDING, COATING, AND CUTTING: AN ...  

Science.gov (United States)

... 31. New electric forming methods offer potentials for light metals; magnetic forming and plasma forming. ... 3, 25 Magnetic Forming ..... ...

1963-02-01

449

Mechanism of viscosity effect on magnetic island rotation  

Energy Technology Data Exchange (ETDEWEB)

It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)

2000-04-01

450

Magnetic Properties of Ni Nanoparticles Embedded in ...  

Science.gov (United States)

... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...

2011-05-14

451

Localization of small magnets against a noisy background  

Science.gov (United States)

Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.

2001-05-01

452

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

453

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...

2005-02-01

454
455

Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system  

Energy Technology Data Exchange (ETDEWEB)

A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI ...

2009-05-15

456

Evaluation of Commercial Magnetic Descalers.  

Science.gov (United States)

With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...

1984-01-01

457

Develop Magnetic Coil Design and Manufacturing Capability.  

Science.gov (United States)

... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...

1974-11-01

459

CONTRACT: NAS 8-11811 DESIGN, DEVELOPMENT, MANUFACTURE, AND ...  

Science.gov (United States)

has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magnetic coil is placed over a thin aluminum ...

460

Application of the grazing angle polarized neutron reflectometry to study the magnetism in thin films and stratified media  

Energy Technology Data Exchange (ETDEWEB)

From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...

1992-12-01

461

Anisotropic forming of magnetic powders mixed with ultraviolet resin; Shigaisen koka jushi wo mochiita jisei funmatsu no haiko seikei  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...

1999-01-15

462

An Advance in Superconducting Magnet Technology Opens the Door...  

Science.gov (United States)

magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...

2011-08-20

463

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-07-01

464

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

465

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

466

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

467

Magnetic properties of a SmNiSn single crystal  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the ...

2003-04-01

468

Development of magnetic drive packless valves for commercial purpose  

Energy Technology Data Exchange (ETDEWEB)

A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting ...

1995-09-01

469

Challenges in fabrication of 180deg magnet chamber  

International Nuclear Information System (INIS)

180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector ...

2006-11-01

470

AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab  

Energy Technology Data Exchange (ETDEWEB)

Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar ...

1992-09-01

471

Students' general and physics epistemological beliefs: a twofold phenomenon  

British Library Electronic Table of Contents (United Kingdom)

Background: Although research on epistemological beliefs has expanded over the past two decades, there are still some issues that need to be explored, such as whether epistemological beliefs are domain general or domain specific. Purpose: One of the purposes of this research was to determine if high school students' general epistemological beliefs were different from their epistemological beliefs in the domain of physics. Sample: The research was conducted with 15 grade nine students studying in an urban all-boys school. Their average age was 16. Their previous school experiences were traditional oriented. Design and methods: A case study design with qualitative methods was used for the research. Two questionnaires were developed and used in semi-structured interview protocols two times, w...

2011-01-01

472

Numerical evaluation of effective unsaturated hydraulic properties for fractured rocks  

Energy Technology Data Exchange (ETDEWEB)

To represent a heterogeneous unsaturated fractured rock by its homogeneous equivalent, Monte Carlo simulations are used to obtain upscaled (effective) flow properties. In this study, we present a numerical procedure for upscaling the van Genuchten parameters of unsaturated fractured rocks by conducting Monte Carlo simulations of the unsaturated flow in a domain under gravity-dominated regime. The simulation domain can be chosen as the scale of block size in the field-scale modeling. The effective conductivity is computed from the steady-state flux at the lower boundary and plotted as a function of the averaging pressure head or saturation over the domain. The scatter plot is then fitted using van Genuchten model and three parameters, i.e., the saturated conductivity K{sub s}, the air-entry parameter {alpha}, the pore-size distribution parameter n, corresponding to this model are considered as the effective K{sub s}, ...

2009-01-01

473

Mechanism of Dephosphorylation of the SR Protein ASF/SF2 by Protein Phosphatase 1  

British Library Electronic Table of Contents (United Kingdom)

SR proteins are essential splicing factors whose function is controlled by multi-site phosphorylation of a C-terminal domain rich in arginine-serine repeats (RS domain). The protein kinase SRPK1 has been shown to polyphosphorylate the N-terminal portion of the RS domain (RS1) of the SR protein ASF/SF2, a modification that promotes nuclear entry of this splicing factor and engagement in splicing function. Later, dephosphorylation is required for maturation of the spliceosome and other RNA processing steps. While phosphates are attached to RS1 in a sequential manner by SRPK1, little is known about how they are removed. To investigate factors that control dephosphorylation, we monitored region-specific mapping of phosphorylation sites in ASF/SF2 as a function of the protein phosphatase PP1. W...

2010-01-01

474

Knowledge Encapsulation Framework for Collaborative Social Modeling  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the Knowledge Encapsulation Framework (KEF), a suite of tools to enable knowledge inputs (relevant, domain-specific facts) to modeling and simulation projects, as well as other domains that require effective collaborative workspaces for knowledge-based task. This framework can be used to capture evidence (e.g., trusted material such as journal articles and government reports), discover new evidence (covering both trusted and social media), enable discussions surrounding domain-specific topics and provide automatically generated semantic annotations for improved corpus investigation. The current KEF implementation is presented within a wiki environment, providing a simple but powerful collaborative space for team members to review, annotate, discuss and align evidence with their modeling frameworks. The novelty in this approach lies in the combination of automatically tagged and user-vetted resources, ...

2009-03-24

475

Insight into Thyroid-Stimulating Autoantibody Interaction with the Thyrotropin Receptor N-Terminus Based on Mutagenesis and Re-Evaluation of Ambiguity in This Region of the Receptor Crystal Structure  

British Library Electronic Table of Contents (United Kingdom)

Background: Thyroid-stimulating autoantibodies (TSAb) bind to the thyrotropin receptor (TSHR) extracellular domain, or ectodomain (ECD), comprising a leucine-rich repeat domain (LRD) linked by a hinge region to the transmembrane domain (TMD). The LRD (residues 22???260; signal peptide 1???21) contains two disulfide-bonded loops at its N-terminus. In the crystal structure of the isolated LRD complexed with human TSAb monoclonal antibody (mAb) M22, N-terminal disulfide loop 1 (residues 22???30) could not be determined because of crystal disorder. Nevertheless, present crystal structure data are interpreted to exclude a role for the LRD N-terminal disulfide loops in the TSAb epitope(s), contradicting prior functional evidence of a role for these loops in TSAb function. Materials and Methods: ...

2011-01-01

476

Bacteriophage P22 capsid size determination: Roles for the coat protein telokin-like domain and the scaffolding protein amino-terminus  

British Library Electronic Table of Contents (United Kingdom)

Assembly of icosahedral capsids of proper size and symmetry is not understood. Residue F170 in bacteriophage P22 coat protein is critical for conformational switching during assembly. Substitutions at this site cause assembly of tubes of hexamerically arranged coat protein. Intragenic suppressors of the ts phenotype of F170A and F170K coat protein mutants were isolated. Suppressors were repeatedly found in the coat protein telokin-like domain at position 285, which caused coat protein to assemble into petite procapsids and capsids. Petite capsid assembly strongly correlated to the side chain volume of the substituted amino acid. We hypothesize that larger side chains at position 285 torque the telokin-like domain, changing flexibility of the subunit and intercapsomer contacts. Thus, a sing...

2011-01-01

477

A multidimensional hybrid intelligent method for gear fault diagnosis  

British Library Electronic Table of Contents (United Kingdom)

Identifying gear damage categories, especially for early faults and combined faults, is a challenging task in gear fault diagnosis. This paper proposes a new multidimensional hybrid intelligent diagnosis method to identify different categories and levels of gear damage automatically. In this method, Hilbert transform, wavelet packet transform (WPT) and empirical mode decomposition (EMD) are performed on gear vibration signals to extract additional fault characteristic information. Then, multidimensional feature sets including time-domain, frequency-domain and time-frequency-domain features are generated to reveal gear health conditions. Multiple classifiers based on several classification algorithms and input features are combined with genetic algorithm (GA). Because of the use of multidim...

2010-01-01

478

Magnetic resonance imaging of the urogenital diaphragma in comparison with conventional histomorphological findings (the controversy about the deep transverse muscle of perineum); Kernspintomographische Untersuchungen des Diaphragma urogenitale im Vergleich mit korrespondierenden histomorphologischen Befunden (der Streit um den Misculus transversus perinei profundus)  

Energy Technology Data Exchange (ETDEWEB)

The transversus perinei profundus muscle is a well known structure in found anatomical textbook. Fibres of this muscle are believed to form the so-called external urethral sphincter (musculus sphincter urethrae). Recently histomorphologic investigations have shown that there is no muscular connection between the musculus sphincter urethrae (external sphincter) and the muscle system of the pelvic floor. Furthermore, the external sphincter was found to be divided into parts: The transversely striated part (musculus sphincter urethrae transversostriatus) and the smooth part (musculus sphincter urethrae glaber). Similar to histomorphologic investigations, contrast-enhanced MR imaging has shown the musculus sphincter urethrae to be surrounded by fatty and connective tissue only. Neither in MRI nor in anatomical slices can any connection between the urethral sphincter and the muscle system of the pelvic floor be found. Thus, on the basis of the results presented in this ...

1997-01-01

479

Inflammatory spine disease as a cause of back pain; Entzuendliche Wirbelsaeulenerkrankungen als Ursache fuer Rueckenschmerzen  

Energy Technology Data Exchange (ETDEWEB)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-{alpha} antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-{alpha} antagonists is based on clinical and laboratory criteria, and signs of ...

2006-06-15

480

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...

1992-01-01

481

The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries  

UK PubMed Central (United Kingdom)

The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available

2010-01-01

482

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

483

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

484

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

485

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

486

Nonnegative Factorization of Diffusion Tensor Images and Its Applications  

UK PubMed Central (United Kingdom)

This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available

2011-01-01

487

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

488

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

489

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

490

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

491

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

492

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

493

Comprehensive Quantification of Signal-to-Noise Ratio and g-Factor for Image-Based and k-Space-Based Parallel Imaging Reconstructions  

UK PubMed Central (United Kingdom)

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available

2008-10-01

494

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...

2007-09-21

495

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

496

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-01-01

497

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

498

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01