... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...
Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.
The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. ...
The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.
A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a ...
This patent describes an ignition system of an internal combustion engine which consists of: a permanent magnet supported by a rotary member of the engine adapted to rotate in synchronism with a rotary shaft of the engine; a generating coil for generating an electromotive force to produce an electric current as the permanent magnet acts on the generating coil during the rotation of the rotary member; an ignition capacitor charged by the electric current generated by the generating coil; a thyristor caused to turn on by a counter electromotive force generated by the generating coil to thereby cause the ignition capacitor to begin to discharge; and an ignition coil generating a high voltage as the ignition capacitor begins to discharge, to cause a spark discharge to take place in an ignition plug of the internal combustion engine.
has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magneticcoil is placed over a thin aluminum ...
The mapping of the magnetic flux bundle from the center cell to the Plasma Potential Control plates (PPC) on the end fan of the Tandem Mirror Experiment Upgrade (TMX-U), was improved by the addition of trim coils (12,000 amp-turns) on each side of each end fan next to the pump beam magnetic shields. The coils' axes are oriented perpendicular to the machine centerline. These coils made the necessary corrections to the field-line mapping, while keeping the field in the nearby pump beam magnetic shield below the saturation threshold. This paper briefly describes the problem, discusses the design as it evolved, and presents the results of the field testing. A brief description of the improvement in the machine performance is also included.
MAGNETIC FORMING BERYLLIUM COIL ASSEMBLY. By. J. W. Rogers, D. D. Wier, and M. E. Davis. Department of Electrical Engineering. Mississippi State University ...
All MBI bending magnets in each of the two LHC injection transfer lines will be powered in series. The limited output voltage of existing power converters lead to an unusual coil design avoiding external return bus-bars by combining two overlapping half-coils, electrically separated, with 3 1/2 turns each in a monolithic structure. The voltage between turns in one coil can reach up-to 3.6 kV. The coil has been designed with particular care for obtaining high interturn and ground insulation. Flux-free soldering of connections with plug-in cone sleeves is applied, allowing to execute water cooled current connections as prolongation of the coil conductor. Epoxy compound polymerization in the impregnation mould is obtained by passing overheated water in regulated cycles through the water circuit of the coil conductor. We describe the design ...
One of the most complicated tasks during the assembly of the Wendelstein W7-X is the installation of the superconductive coil system. The entire magnet system is enclosed between the Outer Vessel and the plasma vessel in high vacuum at 4 K. The coils are supported by a support structure, the Central Support Structure (CSS). The CSS carries all 70 coils, and it is designed as a closed ring made of 5 modules (10 half modules). The whole structure is supported by 10 Cryolegs which rest on the machine base. This paper describes the final design and manufacture of these Cryolegs.
The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.
The transition region between the straight part and the ends of the coils of the LHC model and prototype dipole magnets are often identified as the origin of training quenches. In order to study how the discontinuities in the material properties of these regions affect coil pre-stress and possibly gain more insight in the quench behavior, a program was set up at CERN to analyze by 3D-FEM these particular regions. The ACCEL team, who performed a similar analysis for the main quadrupoles of the Superconducting Supercollider SSC, is entrusted with this program. In this paper we report on the results of 3D-modeling and analysis of the coil return end region, including the complete coil mass, of a 1-m single bore model magnet. This magnet represents all relevant features of the "two-in-one" LHC main dipole design concerning the winding ...
Coilguns have the ability to provide magnetic pressure to projectiles which results in near constant acceleration. However, to achieve this performance and control projectile hearing, significant constraints are placed on the design of the coils. We are developing coils to produce an effective projectile base pressure of 100 MPa (1kbar) as a step toward reaching base pressures of 200 MPa. The design uses a scalable technology applicable to the entire range of breech to muzzle coils of a multi-stage launcher. This paper presents the design of capacitor-driven coils for launching nominal 50 mm, 350 gram projectiles. Design criteria, constraints, mechanical stress analysis, launcher performance, and test results are discussed.
This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...
The Compact Muon Solenoid (CMS) is one of the experiments which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN. The design field of the CMS magnet is 4 T, the magnetic length is 12.38 m and the aperture is 6.36 m. This is achieved with a 4 layer-5 module superconducting Al-stabilized coil energised at a nominal current of 20 kA. The finite element analysis (FEA) carried out is axisymmetric elasto-plastic. FEA has also been carried out on the suspension system and on the conductor. (8 refs).
Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.
A dipole magnet based on the common coil design, using prereacted Nb{sub 3}Sn superconductor, is under development at Fermilab, for a future Very Large Hadron Collider. This magnet has some innovative design and technological features such as single layer coils, a 22 mm wide 60-strand Rutherford type cable and stainless steel collars reinforced by horizontal bridges inserted between coil blocks. Both left and right coils are wound simultaneously into the collar structure and then impregnated with epoxy. In order to optimize the design and fabrication techniques an R&D program is underway. The production of cables with the required characteristics was shown possible. Collar laminations were produced, assembled and tested in order to check the effectiveness of the bridges and the validity of the mechanical design. A mechanical model consisting of a 165 mm ...
The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy ...
Coilguns have demonstrated their capability to launch projectiles to 1 km/s, and there is interest in their application for long-range precision strike weapons. However, the incorporation of cooling systems for repetitive operation will impact the mechanical design and response of the future coils. To assess the impact of such changes, an evaluation of the ruggedness and reliability of the existing 50 mm bore coil designed in 1993 was made by repeatedly testing at stress levels associated with operation in a coilgun. A two-coil testbed has been built with a static projectile where each coil is energized by its own capacitor bank. Simulation models of the applied forces generated in this testbed have been created with the SLINGSHOT circuit code to obtain loads equivalent to the worst-case anticipated in a 50 mm coilgun that could launch a 236 g projectile to 2 km/s. Bench measurements of the seven ...
Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently ...
number of technical requirements and performance criteria can drive stellarator costs, e.g., tight tolerances, accurate coil positioning, low aspect ratio (compactness), choice of assembly strategy, metrology, and complexity of the stellarator coil geometry. With the completion of a seven-year design and construction effort of the National Compact Stellarator Experiment (NCSX) it is useful to interject the NCSX experience along with the collective experiences of the NCSX stellarator community to improving the stellarator configuration. Can improvements in maintenance be achieved by altering the stellarator magnet configuration with changes in the coil shape or with the combination of trim coils? Can a mechanical configuration be identified that incorporates a partial set of shaped fixed stellarator coils along with some removable coil set to ...
A number of technical requirements and performance criteria can drive stellarator costs, e.g., tight tolerances, accurate coil positioning, low aspect ratio (compactness), choice of assembly strategy, metrology, and complexity of the stellarator coil geometry. With the completion of a seven-year design and construction effort of the National Compact Stellarator Experiment (NCSX) it is useful to interject the NCSX experience along with the collective experiences of the NCSX stellarator community to improving the stellarator configuration. Can improvements in maintenance be achieved by altering the stellarator magnet configuration with changes in the coil shape or with the combination of trim coils? Can a mechanical configuration be identified that incorporates a partial set of shaped fixed stellarator coils along with some removable coil set ...
This paper deal with the research and develop (R and D) on Control Rod Magnetic Suspension Drive Mechanism (MSDM) of CARR. The MSDM is made up of tube, coil, armature, step motor, lead screw etc. The MSDM use electromagnetics as its main principle. The open solenoid electromagnet technique is employed to implement suspension function. It has advantages of high drive precision, high safety feature, good running reliability, easy maintenance and good economical property. The R and D process of MSDM has three phases including single coil electromagnet, principle prototype and engineering prototype. (author)
The concept of the minimum propagating zone (MPZ) is used to examine the causes of quenches in ISABELLE cosine theta superconducting dipole magnets. The size of disturbances large enough to exceed the MPZ and initiate quenches is estimated and compared with the size of disturbances which may be produced in the magnets. A suggestion for reducing the size of these disturbances through individual support of the coil block is outlined.
The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.
Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer ...
The UTST (University of Tokyo Spherical Tokamak) device was constructed for the purpose of exploring the formation of ultra-high beta ST (Spherical Tokamak) plasma using the double null plasma merging method. When two plasmas merge together to form a single plasma, magnetic field lines reconnect, and the magnetic field energy is converted to the plasma kinetic energy, increasing the plasma beta. The merging start-up has been demonstrated in the TS-3/4, START and MAST devices using coils inside the vacuum vessel and TS-3 plasma obtained 50% beta. In order to demonstrate the start-up in a more reactor relevant situation, UTST has all poloidal field coils outside the vacuum vessel. The first plasma experiment on the UTST was performed from December, 2007. In the result, the plasma obtained 10 kA by using only outer PF coils and single ST was generated at the lower area (z=-0.3 - ...
The motivation for this design study has been to identify magnet designs for useful magnetic fusion experiments which minimize capital cost. Some possibly useful novel design features have been identified. 5 refs., 6 figs., 3 tabs.
This report presents the results of a study of the Japanese MLU magnetic-levitation (maglev) system. The development of the MLU system is reviewed, and the dynamic circuit model then is introduced and applied to the figure-eight-shaped null-flux coil suspension system. Three different types of figure-eight-shaped null-flux suspension systems are discussed in detail: (1) the figure-eight-shaped null-flux coil suspension system without cross-connection; (2) the combined suspension and guidance system; and (3) the combined propulsion, levitation, and guidance system. The electrodynamic-suspension maglev systems developed in Japan seem to be very promising and could result in a commercial application in the near future.
Several short model SSC 50 mm bore dipoles are being built and tested at Fermilab. Mechanical design of these magnets has been determined from experience involved in the construction and testing of 40 mm dipoles. Construction experience includes coil winding, curing and measuring, coil end part design and fabrication, ground insulation, instrumentation, collaring and yoke assembly. Fabrication techniques are explained and construction problems are discussed. Similarities and differences from the 40 mm dipole tooling and management components are outlined. Test results from the first models are presented. 19 refs., 12 figs.
Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737
The first essential before embarking on the radiation-hardening of electrical insulation - mostly magnetcoils - in any beam line application is to obtain a reliable estimate of the dose to the components. These are examples ( switchyards at SLAC and LAMPF) where the degree of hardness specified was much higher than was required. Although experience shows that the cost premium for substantial radiation - hardening is of the order of 10%, it has also become clear that well - designed beam line have negligible losses: hardening is required only in the vicinity of targets, collimators or other beam - intercepting devices. Where the beam is deliberately scraped, local shielding will minimize the associated radiation in the surroundings. Electron machines have their own special problems due to synchrotron radiation, so certainly coils and other electrical equipment should be kept away from the beam bend - plane. Because proton ...
Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some ...
It is well known that one of the main advantages of the high speed forming (HSF) processes is the improvement in the forming limits of the used materials.Using the Electromagnetic Forming (EMF) technology two materials have been tested with different mechanical and physical properties: the AA5754 aluminium and the AZ31B magnesium alloys.The EMF process principle can be described as follows: A significant amount of electrical energy is stored in a bank of capacitors which are suddenly discharged releasing all the stored energy. This electric discharge runs through a coil which generates an intense transient magnetic field. At the same time transient Eddy currents are induced in the electrically conductive part placed some millimetres far from the coil. Another intense magnetic field is generated due to those Eddy currents but on the opposite direction as the one generated by the ...
It is well known that one of the main advantages of the high speed forming (HSF) processes is the improvement in the forming limits of the used materials.Using the Electromagnetic Forming (EMF) technology two materials have been tested with different mechanical and physical properties: the AA5754 aluminium and the AZ31B magnesium alloys.The EMF process principle can be described as follows: A significant amount of electrical energy is stored in a bank of capacitors which are suddenly discharged releasing all the stored energy. This electric discharge runs through a coil which generates an intense transient magnetic field. At the same time transient Eddy currents are induced in the electrically conductive part placed some millimetres far from the coil. Another intense magnetic field is generated due to those Eddy currents but on the opposite direction as the one generated by the ...
A generic reactor model is used to examine the economic viability of electricity generation by magnetic fusion. The simple model uses components which are representative of those used in previous reactor studies of deuterium-tritium burning tokamaks, stellarators, bumpy tori, reverse field pinches and tandem mirrors. Conservative costing assumptions are made. The generic reactor is not a tokamak but rather it is intended to emphasize what is common to all magnetic fusion reactors. The reactor uses a superconducting toroidal coil set to produce the dominant magnetic field. To this extent it is a less good approximation to systems, such as the reversed field pinch in which the main field is produced by a plasma current. The main output of the study is the cost of electricity as a function of the weight and size of the fusion core - blanket, shield, structure and coils. The model shows ...
The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and ...
Purpose - The purpose of this paper is to investigate the accuracy of different force calculation methods and their impact on mechanical deformations. For this purpose, a micrometer scaled actuator is considered, which consists of a micro-coil and of a permanent magnet (PM) embedded in a deformable elastomeric layer. Design/methodology/approach - For the magnetic field evaluation a hybrid numerical approach (finite element method/boundary element method (FEM/BEM) coupling and a FEM/BEM/Biot-Savart approach) is used, whereas FEM is implemented for the mechanical deformation analysis. Furthermore, for the magneto-mechanical coupling several force calculation methods, namely the Maxwell stress tensor, the virtual work approach and the equivalent magnetic sources methods, are considered and co...
The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system ...
The plastic deformation behavior of formed CICC for the superconducting Tokamac fusion device was examined and appropriate manufacturing information was provided. A relation between travel of the bending roller and spring back displacement was obtained via virtual manufacturing. The radius of CICC after forming was expressed as a function of the bend-roll travel. The maximum von Mises stress after spring back was also monitored for the SAGBO prediction. Next, the variation of the CICC cross-sectional area was examined during the first turn and during conduit bending with the largest curvature. Finally, the coil radius was measured and compared with the data generated from the virtual manufacturing. The measured data showed similar pattern as predicted one. Using the mapping function found to match with the real data, the data from the virtual manufacturing may facilitate accurate manufacturing.
The plastic deformation behavior of formed CICC for the superconducting Tokamac fusion device was examined and appropriate manufacturing information was provided. A relation between travel of the bending roller and spring back displacement was obtained via virtual manufacturing. The radius of CICC after forming was expressed as a function of the bend-roll travel. The maximum von Mises stress after spring back was also monitored for the SAGBO prediction. Next, the variation of the CICC cross-sectional area was examined during the first turn and during conduit bending with the largest curvature. Finally, the coil radius was measured and compared with the data generated from the virtual manufacturing. The measured data showed similar pattern as predicted one. Using the mapping function found to match with the real data, the data from the virtual manufacturing may facilitate accurate manufacturing.
One of the major achievements of the magnet R&D program for the Superconducting Super Collider (SSC) is the fabrication and test of a series of 20 5-cm aperture, 15-m long dipole magnet prototypes. The ramp rate sensitivity of these magnets appears to fall in at least two categories that can be correlated to the manufacturer and production batch of the strands used for the inner-coil cables. The first category, referred to as type-A, is characterized by a strong quench current degradation at high ramp rates, usually accompanied by large distortions of the multipole fields and large energy losses. The second category, referred to as type-B, is characterized by a sudden drop of quench current at low ramp rates, followed by a much milder degradation at larger rates. The multipole fields of the type-B magnets show little ramp-rate sensitivity, and the energy losses are smaller than ...
The stability of a forced-flow cooled superconducting coil is investigated by use of the numerical simulation. The numerical code to integrate the simultaneous partial differential system composed of the 1 D hydrodynamic equations and the 1 D thermal conduction equation has been developed and stability margins are evaluated as functions of coolant mass flow rate, operation current and imposed magnetic field. The results of computations show that the stability margin is multi-valued with respect to these operation parameters, as expected from the experimental results. It is also shown that the appearance of the first unstable regime is closely related to the existance of the stagnant region located at the upstream side of the heated zone and that the second stable regime appears because the heat transfer is appreciably enhanced by the induced backflow due to the thermal expansion of coolant. 13 refs., 13 figs., 1 tab.
High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel ...
Eddy current testing is one of the most widely used methods in non-destructive testing for the inspection of conductive materials. Numerical modelling of eddy current testing has emerged as an important approach alongside experimental studies. This paper investigates an application of numerical modelling and experimental study as a means of the quantitative non-destructive evaluation (QNDE) of defects in conductive samples. There are two methods of measuring eddy current response, more commonly by measuring the change in impedance of the eddy current probe coil, or as used in this work, by measuring the change in magnetic field directly using magnetic field sensors such as superconducting quantum interference devices, giant magneto resistance, or as in this case Hall sensors. Specifically,...
Over the last year-and-a-half, several 4-cm-aperture, 17-m-long dipole magnet prototypes were built by Brookhaven National Laboratory (BNL) under contract with the Superconducting Super Collider (SSC) Laboratory. These prototypes are the last phase of a half-decade-long R D program, carried out in collaboration with Fermi National Accelerator Laboratory and Lawrence Berkeley Laboratory, and aimed at demonstrating the feasibility of the SSC main ring dipole magnets. They also prepare the way of the 5-cm-aperture dipole magnet program to be started soon. In this paper, we analyze the mechanical behavior of the BNL prototypes during cool-down and excitation, and we attempt to relate this behavior to the magnet features. The data reveal that the mechanical behavior is sensitive to the vertical collar-yoke interference, and that the magnets exhibited somewhat erratic changes in ...
The power source facilities of JT-60 consist of poloidal magneticcoil power source, toroidal magneticcoil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual relating and retrieval by making mounted parts and spare parts into a data base and doing their unified ...
A transient eddy current measurement method is presented to determine the thickness and conductivity of a conductive plate. The conductive plate is induced by an air-cored coil, the magnetic flux density along the axial is measured and the various signals corresponding to plates with different thickness and conductivity are calculated using a 3D transient eddy current simulator. Characteristic features are obtained from the transient response. A similarity-based modeling method is utilized in this study to estimate the thickness and conductivity of the conductive plate. (author)
Magnetic fields can be compensated by opposing fields. This principle can be applied for reducing the magnetic fields emanating from high-voltage transmission lines or found in residential or commercial buildings. The article shows a number of concrete options for reducing magnetic fields in the vicinity of high-voltage lines through appropriate conductor configuration on the one hand, and a novel method using Helmholtz coils for compensating those fields in buildings. (orig.) [Deutsch] Magnetische Felder koennen durch Gegenfelder kompensiert werden. Dieses Prinzip laesst sich sowohl auf Hochspannungsleitungen als auch auf Wohn- und Arbeitsraeume uebertragen. Der Artikel zeigt konkrete Moeglichkeiten, wie einerseits Magnetfelder von Hochspannungsleitungen durch eine geeignete Konfiguration der Leiter reduziert werden koennen, und beschreibt andererseits eine neue Methode zur Reduktion solcher Felder in ...
In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.
Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high {Tc} superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high {Tc} superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is ...
The force exerted on the rotor by an active magnetic bearing (AMB) is determined by the current flow in the magnetcoils. This force can be controlled very precisely, making magnetic bearings a potential benefit for grinding, where cutting forces act as external disturbances on the shaft, resulting in degraded part finish. It is possible to achieve precise shaft positioning, reduce vibration of the shaft caused by external disturbances, and even damp out resonant modes. Adaptive control is an appealing approach for these systems because the controller can tune itself to account for an unknown periodic disturbance, such as cutting or grinding forces, injected into the system. In this paper the authors show how one adaptive control algorithm can be applied to an AMB system with a periodic disturbance applied to the rotor. An adaptive algorithm was developed and implemented in both simulation and hardware, ...
The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures are costly both financially, and from the time to recover from this downstream failure. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers for example, which drastically reduce the mechanical integrity of the strand, and thus the cable itself. But because of the large volume of cable which will be manufactured an automated flaw detection system which can inspect the cable and detect these type of defects will be needed. We have recently done an on-line experiment using an Eddy current system, and specialized Eddy current probes to inspect cable during manufacturing. We will present the results of our inspection demonstrating ...
The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures is costly both financially and because of the time needed to recover from them. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers, which drastically reduce the mechanical integrity of the strand and thus of the cable itself. But because of the large volume of cable that will be manufactured, an automated flaw detection system that can inspect the cable and detect these types of defects will be needed. We have recently done an on-line experiment using an Eddy current system and specialized Eddy current probes to inspect cable during manufacturing. We will present the results of our inspection, demonstrating detection of ...
We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation (CE+)) methods and the lesions using the SPGR (CE+) method after ...
The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to ...
The NRL Long Pulse Induction Linac is being employed in a Free Electron Laser (FEL) experiment. The authors present results of beam transport and focusing experiments as well as measurements of the output radiation generated by various magnetic wigglers. The electron gun of the accelerator presently has a 17-cmdiam. cold cathode which is located in a nearly zero magnetic field (B /SUB z/ less than or equal to 5 G). The gun voltage is flat to within approx. = + or - 5% for 1.5 #mu#sec with this graphite brush cathode. The beam is focused by a series of solenoidal coils as it propagates through the 4-m-long accelerator."2 A solenoidal field which can be varied from 1-10 kG confines the beam in the FEL interaction region. Previous experiments were limited by poor beam transport, focusing, and matching into the relatively large solenoidal field in the FEL region. By smoothing the axial magnetic field ...
The lasing of the first free-electron laser (FEL) in the world was successfully carried out in 1977, so the history of FELs as a light source is not so long. But FELs are now utilized for research in many scientific and engineering fields owing to such characteristics as tunability of the wavelength, and short pulse and high peak power, which is difficult utilizing a common light source. Research for industrial applications has also been carried out in some fields, such as life sciences, semiconductors, nano-scale measurement, and others. The task for the industrial use of FEL is the realization of high energy efficiency and high optical power. As a means of promoting realization, the combining of an FEL and superconducting linac is now under development in order to overcome the thermal limitations of normal-conducting linacs. Further, since tuning the wavelength is carried out by changing the magnetic density of the undulator, which is now induced by moving part ...
Model construction of the laboratory scale superconducting fault current limiter circuit (SFCL) has been performed. The SFCL is fault current limiter and used as electric network security. It mainly consists of a copper coil, a superconducting ring and an iron core that are concentrically arranged. The SFCL circuit is essentially a transformer where the secondary windings are being replaced by the ring of YBa_2Cu_3O_7_-_x superconductor (HTS). The ring has critical transition temperature Tc = 92 K and critical current Ic = 3.61 A. Characterization of the SFCL circuit is simulated by ANSYS version 5.4 software. The SFCL circuit consists of load and transformer impedances. The results show that the inductions of magnet field flux in the iron core of primer windings and ring disappear to one other before fault state. It means that impedance of the transformer is zero. After the condition a superconductivity behavior of the ring is disappear so ...
The existing theoretical and experimental basis for predicting the levels of resonant static error field at different components m,n that stop plasma rotation and produce a locked mode is reviewed. For ITER ohmic discharges, the slow rotation of the very large plasma is predicted to incur a locked mode (and subsequent disastrous large magnetic islands) at a simultaneous weighted error field ({Sigma}{sub 1}{sup 3}w{sub m1}B{sup 2}{sub rm1}){sup {1/2}}/B{sub T} {ge} 1.9 x 10{sup -5}. Here the weights w{sub m1} are empirically determined from measurements on DIII-D to be w{sub 11} = 0. 2, w{sub 21} = 1.0, and w{sub 31} = 0. 8 and point out the relative importance of different error field components. This could be greatly obviated by application of counter injected neutral beams (which adds fluid flow to the natural ohmic electron drift). The addition of 5 MW of 1 MeV beams at 45{degrees} injection would increase the error field limit by a factor of 5; 13 MW would ...
Nanosatellite space launches could significantly benefit from an electrically powered launch complex, based on an electromagnetic coil launcher. This paper presents results of studies to estimate the required launcher parameters and some fixed facility issues. This study is based on electromagnetic launch, or electromagnetic gun technology, which is constrained to a coaxial geometry to take advantage of the efficiency of closely-coupled coils. A baseline configuration for analysis considers a payload mass of 10 kg, launch velocity of 6 km/s, a second stage solid booster for orbital insertion, and a payload fraction of about 0.1. The launch facility is envisioned as an inclined track, 1-2 km in length, mounted on a hillside at 25 degrees aimed in the orbital inclination of interest. The launcher energy and power requirements fall in the range of 2000 MJ and 2 MW electric. This energy would be supplied by 400 modules of energy storage and ...
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fur Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The ...
The ALICE experimental area management team faces various challenges when it comes to sharing scarce resources, indispensable to any efficient installation in a category one worksite. Space, cranes, jigs, and personnel with key competences have to be carefully allocated to activities so as to avoid slowing down work progress. To this intent, a resource loaded planning has been developed that allows highlighting coactivities and prioritizing critical tasks. It uses the built-in capabilities of Microsoft Project. The use of this scheduling tool leads to a more efficient use of time and a safer work environment. The installation sequence resulting from this schedule is presented in this paper. The first part of the sequence focuses on the revision of the coils in the SX2 building. The dipole has then to be installed in the RB26 side of the UX25 cavern. This complex and resource intensive activity has to be performed in parallel with the services installation inside ...
Electromagnetic forming (EMF) is a forming process that relies on the inductive electromagnetic force to deform metallic workpiece at high speed. Calculation of the electromagnetic force is essential to understand the EMF process. However, accurate calculation requires complex numerical solution, in which the coupling between the electromagnetic process and the deformation of workpiece needs be considered. In this paper, an appropriate formula has been developed to calculate the electromagnetic force in metal work-piece in the sheet EMF process. The effects of the geometric size of coil, the material properties, and the parameters of discharge circuit on electromagnetic force are taken into consideration. Through the formula, the electromagnetic force at different time and in different positions of the workpiece can be predicted. The calculated electromagnetic force and magnetic field are in good agreement with the numerical and experimental ...
The effect of 50 Hz and 60 Hz (frequencies of current distribution) and 20 kHz to 50 kHz (frequencies of induction cooktop) magnetic interference on implanted pacemakers have been assessed with the present generation of device technology. Sixty patients implanted in 1998 and 1999 with dual chamber pacemakers from 9 different manufacturers were monitored with telemetry while passing through, and standing between a system of two coils. They generated a 50 Hz or a 60 Hz magnetic field at 50 microT. Then, patients used a cooktop at different power. The recordings were made with the standard setting of "medically correct" sensing parameters chosen for the patients. Then pacemakers were reprogrammed to the unipolar mode, with the highest atrial (A) and ventricular (V) sensitivity that did not induce muscular inhibition while moving. Between each exposure (50 Hz, 60 Hz or 20 kHz to 50 kHz), the pacemaker programmation was ...
In the present paper we estimate the effect of sodium in the in-service inspection of non-magnetic steam generators tubes using eddy current technique and eddy current probes based on a differential double bobbin coil configuration. Experimental measurements of defects signals in steam generator tubes of fast breeder reactor are compared with simulations results of a two-dimensional axisymmetric finite element code to validate a reliable electromagnetic model of the system (eddy current coils, steam generator tube, defect) when there is no sodium on the outer steam generator tube surface. The electromagnetic code is used to evaluate the sodium band and sodium layer signals when a defect is located under steam generator support plate. Using a multi-frequency algorithm, its parameters are determined in the 'no sodium condition' (there is no sodium on the outer steam generator tube surface), defects signal is enhanced during ...
A new foilless diode with a non-magnetically immersed cathode was recently designed and built for the Sandia Recirculating Linear Accelerator (RLA). Because there is also no radial component of electric field at the cathode, the electron beam starts almost parallel and is matched to a solenoidal transport system with minimum increase in divergence and radius. The electrode emission surface is specified by an area covered with felt which undergoes explosive electron emission at low electrical field stresses (60 kV/cm). The 1.7 MV, 4.8-kA produced beam is transported 1.5 meters to the injection region of the racetrack via a system of solenoids and focusing coils. The maximum transverse velocity component at injection point (1.5 m downstream from the cathode surface) is #beta# perpendicular = 0.03 and the radius r = 2.8 cm which give a quite small beam emittance #epsilon# = 0.08 rad-cm. Three- dimensional numerical simulations suggest that ...
MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...
BackgroundCoiled-coil domain containing 115 (Ccdc115) or coiledcoil protein-1 (ccp1) was previously identified as a downstream gene of Fibroblast Growth Factor 2 (FGF2) highly expressed...Full Text Available
In an electromagnetic pump of the present invention for use in circulation of coolants in an LMFBR type reactor, the outer circumference of coil conductors is covered by an insulator retaining cover, and powdery or granular insulator is filled between the coil conductors and the insulator retaining cover. Upon reaching high temperature, elongation of the coil conductors by heat expansion is absorbed by movement of the particles of the powdery insulator thereby preventing excess stresses from exerting on the coil insulator constituted with the insulator retaining cover and the powdery or granular insulator and preventing generation of crackings on the coil insulator. Thus, plant stability is improved. (N.H.).
Future insertion quadrupoles with large apertures and high gradients will be required for the Phase II luminosity upgrade (10{sup 35} cm{sup -2}s{sup -1}) of the Large Hadron Collider (LHC). Although improved designs, based on NbTi, are being considered as an intermediate step for the Phase I upgrade, the Nb{sub 3}Sn conductor is presently the best option that meets the ultimate performance goals for both operating field and temperature margin. As part of the development of Nb{sub 3}Sn magnet technology, the LHC Accelerator Research Program (LARP) developed and tested several 1-meter long, 90-mm aperture Nb{sub 3}Sn quadrupoles. The first two series of magnet used OST MJR 54/61 (TQ01 series) and OST RRP 54/61 (TQ02 series) strands. The third series (TQ03) used OST RRP 108/127 conductor. The larger number of sub-elements and the consequent reduction of the effective filament size, together with an increased fraction of copper and a lower Jc were ...
Kawasaki Steel started the construction of an automatic steel strip coil transportation system in the 1980's. Presently, most of the in-plant transportation of hot-rolled or cold-rolled coils are automated. For establishing the automatic transportation, there were developed various technologies, such as, the optimum handling technology using artificial intelligence, the technology of preventing additional piling of coils on existing coils by using an ultrasonic wave and a laser beam. Through the improvements of these technologies, a full-automated transportation system has been achieved and the system has contributed substantially toward product quality assurance and cost reduction. This paper gives the changes in the automation technology of coil transportation in the automation of No. 3 finishing hot rolling mill, now having the latest automatic system, in Chiba Works. ...
A helical cooling channel (HCC) has been proposed to quickly reduce the six-dimensional phase space of muon beams for muon colliders, neutrino factories, and intense muon sources. The HCC is composed of a series of RF cavities filled with dense hydrogen gas that acts as the energy absorber for ionization cooling and suppresses RF breakdown in the cavities. Magnetic solenoidal, helical dipole, and helical quadrupole coils outside of the RF cavities provide the focusing and dispersion needed for the emittance exchange for the beam as it follows a helical equilibrium orbit down the HCC. In the work presented here, two Monte Carlo programs have been developed to simulate a HCC to compare with the analytic predictions and to begin the process of optimizing practical designs that could be built in the near future. We discuss the programs, the comparisons with the analytical theory, and the prospects for a HCC design with the capability to reduce the ...
The economic prospects for magnetic fusion energy can be dramatically improved if for the same total power output the fusion neutron first-wall (FW) loading and the system power density can be increased by factors of 3 to 5 and 10 to 30, respectively. A number of compact fusion reactor embodiments have been proposed, all of which would operate with increased FW loadings, would use thin (0.5 to 0.6 m) blankets, and would confine quasi-steady-state plasma with resistive, water-cooled copper or aluminum coils. Increased system power density (5 to 15 MWt/m/sup 3/ versus 0.3 to 0.5 MW/m/sup 3/), considerably reduced physical size of the fusion power core (FPC), and appreciably reduced economic leverage exerted by the FPC and associated physics result. The unique materials requirements anticipated for these compact reactors are outlined against the well documented backdrop provided by similar needs for the mainline approaches. Surprisingly, no single ...
Using the ammonia (NH3) plasma generated by a helical antenna surrounded by two magneticcoils, the transition of the discharge mode from low-density plasma to high-density one was observed. At the transition, the emission intensities from the H atoms and NH radicals especially increased in the optical emission spectroscopy, while the intensities of the other emission lines also increased abruptly. The nitridation of gallium arsenide (GaAs) surface was performed using the high-density NH3 plasma, and the properties of the nitrided surface layer were compared with those nitrided by high-density N2 plasma using the same apparatus. From the spectroscopic ellipsometry measurements, the thickness of the nitrided layer was estimated to be 16-18 nm, while that by N2 was 3-4 nm. From the Ga 3d spectra, the contamination with oxygen in the nitridation layer by NH3 plasma was less than that by N2 plasma.
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of ...
This paper presents a mathematical model that calculates eddy current signals from laterally spaced transmit-receive pancake coils. This model was validated by comparing calculations with laboratory measurements and it has been applied to evaluating design variations in X-Probe eddy current array coils. This model was used to quantify detection capabilities of probe designs with different numbers of coils. The current standard X-Probe design for 13 mm (0.5 inch) diameter steam generator tubes uses 3 rows of coils with 8 coils per row. This design is commonly referred to as the '8 coil X-Probe'. A significant improvement in detection capability was predicted for an X-Probe with 12 coils per row (called the '12 coil X-Probe') detecting short circumferential crack-like flaws. Based on ...
We have investigated the growth behaviors of high temperature compatible ZrO_2 insulation coatings on Ag and AgMg sheathed Bi_2Sr_2Ca_1Cu_2O_x superconducting tapes depending on number of dipping and thermal conditions. The coatings were fabricated on long-length superconducting tape substrates using a solution derived from Zr tetrabutoxide, solvent and chelating agent for high magnetic field magnets. The layer-on-layer growth behaviors were characterized by environmental scanning electron microscope (ESEM), energy dispersive spectroscopy (EDS), X-ray maps and X-ray diffraction (XRD). This research showed that the ZrO_2 coatings were regularly grown on Ag-based tape substrates and coating thickness increased with increasing number of dipping. It was found that ceramic oxides formed at temperature range 450 and 550 deg. C. The final coating thickness changed between 6 and 8 #mu#m after annealing process. Resistance of insulation measured from ...
The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were ...
Tropomyosin (Tm) is a conserved dimeric coiled-coil protein, which forms polymers that curl around actin filaments in order to regulate actomyosin function. Acetylation of the Tm N-terminal...Full Text Available
A novel soft commutated direct current (DC) motor is introduced. The current of the commutated coil is intentionally drained before the brush disconnects the coil. This prevents the spark generation that normally occurs in conventional DC motors. A similar principle can be applied for DC generators.
The minimum energy conformations of dApdA have been examined for their suitability as buildings blocks of the single stranded coil form of polynucleotides. Calculations of the characteristic ratio C...Full Text Available
To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader 2:0.818) showed ...
For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a system of 192 beam ...
The use of deuterium-tritium fuel in the Compact Ignition Tokamak will require applying remote handling technology for ex-vessel maintenance and replacement of machine components. Highly activated and contaminated components of the fusion devices auxiliary systems, such as diagnostics and RF heating, must be replaced using remotely operated maintenance equipment in the test cell. In-vessel remote maintenance included replacement of divertor and first wall hardware, faraday shields, and for an in-vessel inspection system. Provision for remote replacement of a vacuum vessel sector, toroidal field coil or poloidal field ring coil was not included in the project baseline. As a result of recent coil failures experienced at a number of facilities, the CIT project decided to reconsider the question of remote recovery from a coil failure and, in January of 1990, initiated a coil replacement ...
In a prior study, we demonstrated that certain disposable coils are contaminated with zinc and release substantial quantities of Zn during hemodialysis, producing high post-dialysis plasma Zn concentrations. The present investigation was designed to monitor plasma and dialysis fluid Zn and copper throughout dialysis and to estimate patient Zn and Cu uptake. Venous plasma, arterial plasma and coil chamber fluid were sampled periodically throughout dialysis; trace metal concentrations were determined by flame atomic absorption spectrophotometry. Release of considerable quantities of Zn from the coils into the dialysis fluid, with uptake into the patient's plasma, was found. Approximately one-half of the plasma Zn uptake occurred in the first 45 minutes. Coils from different lots released significantly different quantities of Zn. Patient uptake of Zn ranged from 3.2 mg-23.0 mg, with a mean of 15.0 ...
Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated ...
A 67-year-old man presented with gastrointestinal bleeding resulting from a fistula between the aortic stump and the fourth part of the duodenum 14 months after an axillobifemoral bypass, graft excision, and aortic stump closure for aortic graft infection. The patient initially refused any attempt at definitive surgical treatment so coil embolization of the aortic stump was performed via a brachial approach. Coil embolization may be a useful adjunct in the management of such difficult problems. This approach may buy time and allow careful planning of a definitive treatment or may serve as a palliative procedure in inoperable patients. PMID:15947052
This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.
Complete text of publication follows. In order to extend the capabilities of the electron cyclotron resonance (ECR) ion source (ECRIS) of ATOMKI it has been transformed into a special plasma facility [1,2]. The transformation is reversible and was simply done by changing several main components of the ion source by new ones, namely: the hexapole magnet, the plasma chamber and the microwave source. The basic requirements of the transformation were: (1) most parts of the present ECRIS should be used in the new assembly in the same way and (2) the transformation time between the two operation modes should not be more than 2-3 days (in both directions). The following sub-systems are used identically in both configurations: solenoid coils, vacuum system, gas dosing system, ovens, probes. The extraction optics and beam transport system can also be used in the new configuration to check the components and charge-state of the plasma. A new, large, but ...
Transcatheter coil embolization for coronary artery to left ventricular fistula was successfully performed in a neonate. At 30 weeks' gestation, fetal echocardiography showed a hypoplastic right ventricle with intact ventricular septum, absent pulmonary valve, tricuspid atresia, and marked distension of the right coronary artery. After birth, the neonate had congestive heart failure and the electrocardiogram showed myocardial ischemic changes in the left ventricular area. Aortography showed a dilated right coronary artery arising from the ascending aorta and draining into the left ventricle. Transcatheter coil embolization was carried out on the 9th day after birth. Since the procedure, no myocardial ischemic changes have been detected. Transcatheter coil embolization is a useful therapy for coronary artery fistula associated with myocardial ischemia. PMID:15564713
A start safety apparatus of an engine adapted for a multipurpose power tool is described which consists of: an engine, an exciter coil generating alternate electromotive force in synchronism with rotation of the engine; an ignition coil having primary and secondary windings; a spark plug connected to the secondary winding of the ignition coil; a capacitor connected to the primary winding of the ignition coil the capacitor being charged with a positive half-cycle of the electromotive force; ignition timing control means for controlling discharge of the capacitor; a throttle control latch for setting a throttle valve of the engine in a predetermined throttle angle; a tool driven by the engine; and a centrifugal clutch transferring engine power to the tool when an engine speed exceeds a clutch-in speed.
BackgroundPublicly available DNA sequence databases such as GenBank are large, and are growing at an exponential rate. The sheer volume of data being dealt with presents serious...Full Text Available
To overcome the limitations of conventional bobbin style eddy-current probes, it has become common practice to perform some portion of a steam generator tube inspection program with array coil probes. Typically, eight surface-riding pancake coils are utilized in a probe head, either as eight independent coils (8 x 1) or in a parallel combination of four serially connected coils (4 x 4). The advantages of the array coils are improved sensitivity to intergranular attack (IGA), reduced interference from tube denting, and improved sensitivity to circumferential cracking. The current status of commercially available probes is such that several weaknesses in array coils have limited the widespread application of this technology. Task S 301-6 was conceived to address each of the weaknesses in order to produce a more reliable and cost-effective probe. The emphasis was ...
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, and during operation ...
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, and during operation ...
The kinetic and guiding center fluid theories of high-..beta.. plasma containment in mirror machines have been developed in a number of self-consistent models. The geometrical effects of magnetic field and ambipolar potential variation have been incorporated in a bounce-averaged Fokker-Planck code which shows that the square-well model somewhat overestimates the n tau and ..beta.. achievable in a mirror field. Simple analytic approximations to the resulting pressure profiles have been incorporated in three-dimensional fluid-equilibrium codes which show the effect of coil geometry on the maximum ..beta... Strongly curved vacuum fields allow higher ..beta.., but short plasmas in weakly curved fields tend to reverse the curvature locally before the mirror-mode limit is reached. Adiabaticity of particle orbits is described in terms of general formulas, applicable in high-..beta.. plasma equilibria, and is shown to break down close to the ...
Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements are used for surface breaking extrusion defect detection and sizing (single frequency technique with ...
The aim of this study was to determine sensitivity and specificity of magnetic resonance angiography (MRA) for the assessment of durable occlusion of intracranial aneurysms with Guglielmi detachable coils (GDC) and to point out the influence of MRA results in re-intervention strategies. Forty-five patients with 54 aneurysms that were previously treated by endovascular occlusion with GDC were selected for this study. All patients underwent digital subtraction angiography (DSA) and MRA examinations on the same day. The time-of-flight MRA studies were performed on a 1-T scanner. The MRA images were first read by radiologists who were not aware of the DSA results. In a second consensus reading by the neuroradiologists who had performed all interventional procedures of this series, the decision was made as to whether re-treatment was necessary. The distribution of aneurysm sizes, configurations and treatment results were sufficient for an unbiased ...
An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} ...
A home-made 3.1 kWh wind turbine that is promising to be the hottest new wind product to appear for home/farm users in some time, is described. The turbine is installed near a farm house in the high wind area of Mount Forest, Ontario. The turbine is hooked up to a four kilowatt Trace inverter charger which is coupled through a DC disconnect and C-60 charge controller to two sets of solar panels (seven panels of 120 W each by Solarex SX 120, and five panels by Sharp, each providing 1600 watt of solar power). The wind turbine and the solar panels, assisted by two 65-year old refurbished wind turbines, one bank of Gel Cell batteries, and an Onan 5 kW gas generator supply the electrical requirements of a seven member family in a 3400 square foot house. The new turbine is mounted on an 80-foot tower, has three eight foot Kevlar blades that produce a 17 foot overall sweep. The turbine weighs 615 lbs., produces 3.1 kW of pure power at just 310 rpms at a low start up wind speed of just 4 mph. ...
Basement membranes contain several proteoglycans, and those bearing heparan sulfate glycosaminoglycans such as perlecan and agrin usually predominate. Most mammalian basement membranes also contain...Full Text Available
A rare, true aneurysm of a branch of the right subclavian artery is described. Transcatheter coil embolization of the feeder artery was successful in obliterating blood flow into the aneurysm and the mass reduced in size. However, the aneurysm reenlarged over the next week of follow-up due to development and enlargement of the collateral vascular network. Extirpation of the aneurysm was performed. Histopathological examination revealed a true aneurysm. PMID:11833847
Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. 2. We could detected, as anticipated, a defect (outer ...
Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available
... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...
in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...
The Segmented Rail Phased Induction Motor (SERAPHIM) is a compact, pulsed linear induction motor (LIM) offering a unique capability for very high speed train propulsion. It uses technology developed for the Sandia coilgun, an electromagnetic launcher designed to accelerate projectiles to several kilometers per second. Both aluminum cylinders and plates were accelerated to a kilometer per second (Mach 3) by passing through a sequence of coils which were energized at the appropriate time. Although this technology was developed for ultra-high velocity, it can be readily adapted to train propulsion for which, at sea level, the power required to overcome air resistance limits the operational speed to a more modest 300 mph. Here, the geometry is reversed. The coils are on the vehicle and the ``projectiles`` are fixed along the roadbed. SERAPHIM operates not by embedding flux in a conductor, but by excluding it. In this propulsion scheme, pairs of ...
Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...
The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the ...
ObjectiveWe describe our clinical experiences and outcomes in patients who had thromboembolic complications occurring during endovascular treatment of intracerebral aneurysms with...Full Text Available
The soil fungus Trichoderma atroviride, a mycoparasite, responds to a number of external stimuli. In the presence of a fungal host, T. atroviride produces...Full Text Available
The augmentation of the heat transfer by inserting different type turbulators into the channels is the conventional passive enhancement method. The coiled wire is one of the common heat transfer enhancement devices. These turbulators generate almost-periodic vortices into the flow while increasing the heat transfer rate. In this study, the properties of these vortices (i.e. the vortex shedding frequency and amplitudes of the pressure fluctuations of the vortices), flow (vortex)-acoustic coupling and the relation between entropy generation and vortex characteristics were investigated experimentally. Strouhal-Re-N_s_,_a and P_r_m_s-Re-N_s_,_a variations were presented graphically. It was observed that as the pitch increases, the vortex shedding frequencies decrease and the maximum amplitudes of pressure fluctuation of vortices produced by coiled wire turbulators occur with small pitches. In addition, the effects of the turbulators on the heat ...
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...
Many genetic processes depend on proteins interacting with specific sequences on DNA. Despite the large excess of nonspecific DNA in the cell, proteins can locate their targets rapidly. After initial...Full Text Available
Jan 20, 1995 ... Jenn-Air dowedraft cooktop, staintess steel, coil. $75; telephone ans mach, $25. Eric, x31917. $295; President & First Lady premier plus ...
A laminated material composed of glass cloth/polyimide film/epoxy resin will be used as an insulating material for superconducting coil of International Thermonuclear Experimental Reactor (ITER). In order to keep safe and stable operation of the superconducting coil system, it is indispensable to evaluate radiation resistance of the material, because the material is exposed to severe environments such as high radiation field and low temperature of 4 K. Especially, it is important to estimate the amount of gases evolved from the insulating material by irradiation, because the gases affect on the purifying system of liquid helium in the superconducting coil system. In this work, the gas evolution from the laminated material by gamma ray irradiation at liquid nitrogen temperature (77 K) was investigated, and the difference of gas evolution behavior due to difference of composition in the epoxy resin was discussed. It was found ...
The aortovenous fistulas are rare, most of them are aortocaval fistula. The non-caval communication of the fistula is sparse. Herein we report a 47-year-old female diagnosed as traumatic aorto-superior mesenteric vein (Ao-SMV) fistula. The abdominal pain, fullness, and frank bruit on abdominal auscultation suggested the diagnosis of an intra-abdominal arteriovenous fistula. The diagnosis of Ao-SMV was further confirmed by the computed tomography (CT) and aortography. The fistula was successfully treated with transcatheter coil embolization. This is the first case of Ao-SMV fistula. It provides an alternative option of treatment other than conventional surgery. PMID:19327940
This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.
Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into consideration the thermal-hydraulics and the engineering requirements to define the shield configuration. A ...
We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).
Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.
The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...
Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.
... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...
This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.
In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of ...
AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...
An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, it is observed that coiled wire turbulence promoters are more effective at Reynolds numbers less than ...
The SONACO experiments are conducted on an electrically heated 37-pin rod bundle, immersed in liquid sodium and contained within a hexagonal wrapper. The rig was designed to investigate natural convection cooling for a geometry representative of fast reactor fuel assemblies. Heat can be removed from the test section in several ways, but in this paper only the axial cooling mode is examined. Above the heated bundle is a plenum, at the top of which is a cooling coil containing a separate, forced sodium flow. Heat transfer from the bundle to this cooling coil is effected by means of buoyancy driven circulatory flow in the sodium, and in the axial cooling mode almost all the heat is removed by the coil. This mode is intended to simulate the natural convection cooling of a blocked fuel assembly by way of thermosyphon coupling to the inner pool. In this paper experimental results are presented, for the temperatures measured under ...
A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted magnetic flux is within ...
A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.
We previously reported that puromycin-insensitive leucyl-specific aminopeptidase (PILSAP) is required for vascular endothelial growth factor (VEGF)- and basic fibroblast growth factor (bFGF)-induced angiogenesis and for endothelial differentiation from embryonic stem (ES) cells via the aminopeptidase activity of PILSAP. In this study, we searched for molecules that function during angiogenesis with PILSAP. We performed proteome analysis of nuclear extracts from embryoid bodies (EBs) made from ES cells transfected with mutant PILSAP lacking aminopeptidase activity and mock EBs. We identified pigpen, a 67-kDa nuclear coiled body component protein. Immunoprecipitation and western blotting demonstrated the binding of PILSAP and pigpen in endothelial cells (ECs), and this interaction was enhanc...
In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. The difficulties associated with the simulation of a heat exchanger augmented with wire-coil inserts are discussed. (author)
Effect of Abdominal Active Can on DFTs. Introduction: Many patients with implantable cardioverter defibrillators (ICDs) have older lead systems, which are usually not replaced at the time of pulse generator replacement unless a malfunction is noted. Therefore, optimization of defibrillation with these lead systems is clinically important. The objective of this prospective study was to determine if an active abdominal pulse generator (Can) affects chronic defibrillation thresholds (DFTs) with a dual-coil, transvenous ICD lead system. Methods and Results: The study population consisted of 39 patients who presented for routine abdominal pulse generator replacement. Each patient underwent two assessments of DFT using a step-down protocol, with the order of testing randomized. The distal right ...
Direct Flame Impingement involves the use of an array of very high-velocity flame jets impinging on a work piece to rapidly heat the work piece. The predominant mode of heat transfer is convection. Because of the locally high rate of heat transfer at the surface of the work piece, the refractory walls and exhaust gases of a DFI furnace are significantly cooler than in conventional radiant heating furnaces, resulting in high thermal efficiency and low NOx emissions. A DFI furnace is composed of a successive arrangement of heating modules through or by which the work piece is conveyed, and can be configured for square, round, flat, and curved metal shapes (e.g., billets, tubes, flat bars, and coiled bars) in single- or multi-stranded applications.
A six-axis active vibration isolation system (AVIS) is designed by using the direct driven guide and ball contact mechanisms in order to have no cross-coupling between actuators. The point contact configuration gives an advantage of having an easy assembly of eight voice coil actuators to an upper and a base plate. A voice coil actuator is used since it can provide a large displacement and sufficient bandwidth required for vibration control. The AVIS is controlled considering the effect of flexible vibration mode in the upper plate and velocity sensor dynamics. A loop shaping technique and phase margin condition are applied to design a vibration controller. The performances of the AVIS are investigated in the frequency domain and finally validated by comparing with the passive isolation system. The scanning profiles of the specimen are compared together by using the atomic force microscope. The robustness of the AVIS is verified by showing the ...
Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)
To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)
Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before ...
Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...
Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We ...
A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)
A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.
An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current probe from manufacturing anomalies, the ...
Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.
Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several studies on the passive techniques of heat transfer augmentation have been reported. The present paper is a review on progress ...
This study by CTES, L.C. meets two main objectives. First, evaluate the feasibility of using coiled tubing (CT) to drill 1.0 inches-2.5 inches diameter directional holes in hard rocks. Second, develop a conceptual design for a micro borehole drilling platform (MBDP) meeting specific size, weight, and performance requirements. The Statement of Work (SOW) in Appendix A contains detailed specifications for the feasibility study and conceptual design.
Acanthamoeba castellanii myosins IA and IB demonstrate the catalytic properties of a myosin and can support analogues of contractile and motile activity in vitro, but their single, low molecular weight heavy chains, roughly globular shapes, and inabilities to self-assemble into filaments make them structurally atypical myosins. The authors present the complete amino acid sequence of the 128-kDa myosin IB heavy chain, which they deduced from the nucleotide sequence of the gene and which reveals that the polypeptide is a fusion of myosin-like and non-myosin-like sequences. Specifically, the amino-terminal approx. 76 kDa of amino acid sequence is highly similar to the globular head sequences of conventional myosins. By contrast, the remaining approx. 51 kDa of sequence shows no similarity to any portion of conventional myosin sequences, contains regions that are rich in glycine, proline, and alanine residues, and lacks the distinctive sequence characteristics of an ..cap alpha..-helical, ...
Acanthamoeba castellanii myosins IA and IB demonstrate the catalytic properties of a myosin and can support analogues of contractile and motile activity in vitro, but their single, low molecular weight heavy chains, roughly globular shapes, and inabilities to self-assemble into filaments make them structurally atypical myosins. The authors present the complete amino acid sequence of the 128-kDa myosin IB heavy chain, which they deduced from the nucleotide sequence of the gene and which reveals that the polypeptide is a fusion of myosin-like and non-myosin-like sequences. Specifically, the amino-terminal #approx# 76 kDa of amino acid sequence is highly similar to the globular head sequences of conventional myosins. By contrast, the remaining #approx# 51 kDa of sequence shows no similarity to any portion of conventional myosin sequences, contains regions that are rich in glycine, proline, and alanine residues, and lacks the distinctive sequence characteristics of an #alpha#-helical, ...
Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.
A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.
The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...
The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.
Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)
Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...
OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available
Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.
The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).
Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...
Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...
It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)
... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...
Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.
Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries
The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...
A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI ...
With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...
From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...
For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...
magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...
The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the ...
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting ...
180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector ...
Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar ...
Three different magnetic regimes; aerial, surface and buried; each with three different forces, have been used to investigate their effects on the water contents and photosynthetic pigments of sweet basil plants (Ocimum basilicum L.). Two groups of sweet basil seeds, Ocimum basilicum L. have been cultivated, one under normal conditions and the second has been subdivided into three portion (aerial, surface and buried) to examine the effect of different magnetic forces coming from the three directions on the resulted plants. At all directions of magnets, water contents have been significantly affected by the magnetic forces. Chlorophyll A and carotene contents have been affected, as well, according to the three magnetic forces coming from soil surface regime only. Chlorophyll B did not significantly affected by differences magnetic forces in the three regimes, but ...
The effects of a moderate-intensity static magnetic field (SMF) on osteoporosis of the lumbar vertebrae were studied in ovariectomized rats. A small disc magnet (maximum magnetic flux density 180 mT)...Full Text Available
Using the full potential linearized augmented plane wave (FLAPW) method, thickness dependent magnetic anisotropy of ultrathin FeCo alloy films in the range of 1 monolayer (ML) to 5 ML coverage on Pd(0 0 1) surface has been explored. We have found that the FeCo alloy films have close to half metallic state and well-known surface enhancement in thin film magnetism is observed in Fe atom, whereas the Co has rather stable magnetic moment. However, the largest magnetic moment in Fe and Co is found at 1 ML thickness. Interestingly, it has been observed that the interface magnetic moments of Fe and Co are almost the same as those of surface elements. The similar trend exists in orbital magnetic moment. This indicates that the strong hybridization between interface FeCo alloy and Pd gives rise to the large magnetic moment. Theoretically calculated ...
In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)
Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.
The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered
The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.
The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...
The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...
This paper reports that only a few years ago superconducting magnetic separation was viewed as the next major market for superconducting magnets. The first commercial units had been installed, worked flawlessly, and demonstrated real economic viability. The potential market was seen as quite large, and many people believed that superconducting magnetic separation would soon show the same rapid growth that MRI had demonstrated after its initial success. These hopes even prompted IGC, one of the top MRI magnet builders, to form a separate division devoted to magnetic separation. Despite the existence of Magstream, IGC has not been overly active in the market. As a technology that has applications from the clay on the Earth to the soil on the moon, superconducting magnetic separation has yet to become widely used.
The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal force balance in the stellarator-like ...
We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and ...
This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.
We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# function shows that ...
We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.
We discuss how magnetic phenomena affect superconductivity in simple metals, transition metals and alloys thereof, and dilute Rare-Earth alloys. It is shown both qualitatively and quantitatively that superconductors are sensitive probes for studying itinerant spin excitations, local spin excitations associated with nearly magnetic impurities, the effect of the atomic environment on the stability of local magnetic moments, and the nature of the spin order in Rare-Earth alloys. Also, we discuss how magnetic impurities can be used to study the electronic configuration which is responsible for superconductivity in Laves-phase crystals like A-15 compounds and ..beta..-W crystals, for example.
The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.
It has been carried out the magnetic properties determination for high iron oxide content glasses series obtained from a geothite red mud waste from the zinc hydrometallurgy and dolomite and glass cullet as main raw materials. It has been determined the magnetic susceptibility and magnetization values for the glasses here investigated. The results suggest that the magnetic behaviour are depending on the glass chemical composition, so that glasses can be differently classified like ferrimagnetic, ferromagnetic, superparamagnetic and paramagnetic. (Author) 6 refs.
Magnetic fluctuations present in the paramagnetic Mn{sub 0.81}Ni{sub 0.19} system have been investigated by measuring inelastic magnetic neutron scattering from a single crystal at temperatures of 450, 585 and 700 K. Antiferromagnetic correlations are observed to be present at all the temperatures studied. The spectral width of the magnetic scattering has been observed to increase with temperature, while the spatial range of the magnetic correlations is seen to decrease as the temperature is raised. The wave-vector-dependent susceptibility is found to follow a Curie-Weiss law near the (1 0 0) position, in agreement with theoretical predictions.
It is suggested that the magnetic Ap stars can be rotationally decelerated to long periods by the braking action of the associated magnetic field on time scales of order 10"7--10"1"0 years depending on whether the star's dipole field is aligned perpendicular or parallel to the rotation axis. Rotation includes a toroidal magnetic field in the plasma surrounding a star, and the accompanying magnetic stresses produce a net torque acting to despin the star. These results indicate that it is not necessary to postulate mass loss or mass accretion for this purely hydromagnetic braking effect.
In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be effective: (1) Removal of the particles, (2) Corrosion proofing of ...
This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil probe designs, ...
This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil probe designs, and ...
Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to prove the detectability of these probes. (author).
CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can inspect each tube for all ...
CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can inspect each tube for all ...
Detection of fatigue damage cracks in aircraft skin structures is an ongoing NDT challenge. Cracks growing rate is difficult to predict, and for this reason, it is important to detect them as soon as possible to avoid a catastrophic break. Eddy current methods are known and well-accepted techniques which are relatively simple to carry out. However, with conventional inspection of airframe structures using standard driver-pickup eddy current probes, it is difficult to detect small fatigue cracks initiated in the second layer of the skin and in the shadow region at fastener holes. Such difficulty is related to fasteners length and their spacing which reduces test sensitivity. This report explains the development of improved eddy current probe/technique to detect and visualize fatigue cracks in fasteners. In this study, an eddy current array probe was evaluated and new coil design was suggested. Several tests were conducted on an A-300 circumferential joint sample ...
As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the ...
Anisotropic Nd{endash}Fe{endash}B magnet powders can be produced by the hydrogenationdecomposition-desorption-recombination (HDDR) process from Nd{endash}Fe@ xnB{endash}Co{endash}M ({ital M}=Ga, Zr, Nb, Hf, and Ta) alloys. The present status of those HDDR powders and the bonded magnets made from them are reviewed with regards to the powder particle size dependence of their magnetic properties, their magnetic thermal stability, and their magnetization behavior. The results of a mechanistic study on the recombination step are also presented. The magnetic properties of the anisotropic HDDR powder depend relatively little on the powder particle size. Bonded magnets with a density of {approximately}6.20 g/cm{sup 3} and a BH{sub max} of 18.5{endash}20.5 MGOe can be produced from anisotropic HDDR powders with particle sizes of below 300 {mu}m diam. ...
A heat pump was tested in the cooling mode under the following conditions: (1) a steady-state test with 95/sup 0/F (35/sup 0/C) outdoor temperature, various indoor conditions, and a dry indoor coil; (2) a steady-state test with 82/sup 0/F (27.8/sup 0/C) outdoor temperature, various indoor conditions, and a dry indoor coil; (3) a cyclic test with an outdoor room temperature of 82/sup 0/F (27.8/sup 0/C), various indoor conditions, and a dry indoor coil. The indoor conditions were varied as follows: (1) indoor temperatures of 75/sup 0/F (23.9/sup 0/C), 80/sup 0/F (26.7/sup 0/C) and 85/sup 0/F (29.4/sup 0/C); (2) volume flowrates over the evaporator coil of 880 cfm (0.47 m/sup 3//s), 1100 cfm (0.52 m/sup 3//s) and 1425 cfm (0.67 m/sup 3//s); (3) during the off-time the dampers were closed in one test series and kept open with a continuously running air handling fan in another test series; (4) the on and off ...
An insulated letter drop plate comprises a back plate having an opening for the mail having two hinges at its upper part to attach a cover to; a frame for retaining a first insulation around its perimeter and around the opening; and suitable insulation. This back plate is also provided with an upper curved extension to cover and conceal said hinges. A cover is provided with two complementary hinges to be articulated with the first hinges on the back plate, and with a frame around the perimeter for the retention of a second insulation. A wire joins the first and second hinges, and a coil spring on the wire keeps the cover normally closed.
New industrial Non Destructive Testing requires the development of new probes: technologies such as high spatial resolution probes for small breaking flaws detection or flexible probes for complex curved surfaces inspection. The CEA/LIST has designed and integrated 2 probes to answer industrial's constraints. The first one is based on Giant Magneto-Resistance and is able to detect 50 ?m3 flaws. The second one is based on micro-coils etched on kapton and its flexibility is adapted to curved surfaces inspection. Both are multi-elements probes, allowing fast inspection. This paper presents those new probes, their design and their performances.
Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface probes. Two-dimensional voltage diagrams showing ...
Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface probes. Two-dimensional voltage diagrams showing ...
Optimum analytical conditions of the aluminium ion were established by flow injection analysis. Eriochrome Cyanine R(ECR) dye reacts with the aluminium ion at pH 6.0 form a complex that exhibits maximum absorption at 535 nm. Reaction condition including the mixing and the reaction coil length, the concentration and the pH of the buffer solution, temperature, and injection loop volume were optimized to introduce this reaction into flow injection analysis. The results were as follows. A mixing coil length of 0.5 m and a reaction coil length of 4.0 m, the pH 6.0 and 1M of acetate buffer solution, the ECR concentration of 0.56 mM, the reaction temperature of 40 .deg. C, the injection loop volume of 300 #mu#L were chosen as optimum conditions. Under these conditions the detection limit of the aluminium ion was less than 0.05 mg/L and the repeatability was better than 1%. A sampling frequency of 24 times for an hour was achieved. ...
Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY ...
The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was ...
Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus simulating the human ...
With "1"5"1Eu-Moessbauer spectroscopy and other methods the complex magnetic properties of Eu_2PdSi_3, arising from the two crystallographically different lattice sites of the Eu"2"+ ions, have been already studied. Here we study the impact of magnetic dilution of the magnetic Eu"2"+ sites by non-magnetic Y"3"+ ions. A previous specific heat study has found reduced magnetic ordering temperatures with strong indication of disorder effects like in magnetic spin glasses. Here we provide from "1"5"1Eu-Moessbauer spectroscopy detailed information of the impact of Y"3"+ substitution on the magnetic properties of the two lattice sites, well distinguishable in the "1"5"1Eu-spectra. Since the substitution of the larger Eu"2"+ ions by the smaller Y"3"+ ions is connected with a lattice contraction, we also applied high pressure to the Eu_2PdSi_3 sample ...
The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.
The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.
The Recycler ring magnet will be made of Strontium ferrite permanent magnets. A strontium ferrite permanent magnet without compensation has a temperature coefficient of -0.2 % in dB/dT. To compensate this effect, we are utilizing 30 % Ni 70 % Fe alloy, a temperature compensation ferromagnetic material with a low Curie point. To search for optimum commercially available material and optimum condition, we made a couple of simple model magnets, and tested with several different compensating material. The test results are reported and its optimal conditions are shown. Several different configurations were tested including a possible 2 kG magnet configuration.
We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large heating power.
The magnetic properties of polycrystalline and single crystalline rare earth transition metal silicides Gd_xLa_1_-_xMSi (M =Fe, Co) were investigated. Magnetic measurements have been made in static magnetic fields up to 13 kOe and in pulsed magnetic fields up to 250 kOe in the temperature range from 4.2 to 350 K. The magnetic susceptibility in the paramagnetic state of all the investigated compounds obeys the Curie-Weiss law except for LaFeSi and LaCoSi. Increase of the La content in Gd_xLa_1_-_xFeSi compounds leads to a decrease of the Curie and Neel temperatures, which can be explained by a decrease of positive exchange interactions. (orig.).
Sensitive and quick-response nonlinear inductance characteristics are found for high Tc superconducting (YBa/sub 2/Cu/sub 3/O/sub 7-chi/) disk cores at 77K in which soft magnetic BH hysteresis loops are observed. Various quick response magnetic devices such as modulators, amplifiers and sensors are built using these cores. The magnetizing frequency can be set to more than 20 MHz, which is difficult for conventional ferromagnetic bulk materials such as Permalloy amorphous alloys and ferrite. New quick-response fluxgate type magnetic-field sensors are made using ac and dc voltage sources. The former is used for second-harmonic type sensors, while the latter is for voltage-output multivibrator type sensors. Stable and quick-response sensor characteristics were obtained for two-core type multivibrators.
The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.
We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...
The Large Hadron Collider (LHC) will be equipped with several thousands of superconducting corrector magnets. Among the largest ones are the superconducting trim quadrupoles (MQTL). These twin-aperture magnets with a total mass of up to 1700 kg have a nominal gradient of 129 T/m at 1.9 K and a magnetic length of 1.3 m. Sixty MQTL are required for the LHC, 36 operating at 1.9 K in and 24 operating at 4.5 K. The paper describes the design features, and reports the measured quench performance and magnetic field quality of the production magnets. The MQTL magnet production is shared between CERN and industry. This sharing is simplified due to the modular construction, common to all twin-aperture correctors.
Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe_7_8Si_9B_1_3 were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe_7_8Si_9B_1_3. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase (#alpha#-Fe(Si), the grain size, 2-10 nm) is 3-7%. The temperature rise ...
This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.
The investigated hybrid nanocomposite consists of a porous silicon template with electrochemically embedded Ni or Co nanostructures and offers magnetic characteristics which can be tailored by the electrochemical process parameters during fabrication. A twofold magnetic behaviour can be observed, a first one due to the spinmagnetism at magnetic fields below the saturation magnetization of the deposited metals and a second non-saturating term at higher fields (>1 T up to 7 T) above the saturation magnetization. In case of Ni deposited within the pores this non-saturating term shows a paramagnetic characteristic and follows exactly the Curie-Weiss law, whereas for Co/porous silicon samples the temperature dependent magnetization shows some deviations from the Curie Weiss law. In this high field region a difference in the temperature dependence between Ni ...
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available
The magnetic susceptibility and the density of human oxy-(HbO2) and carbonmonoxyhemoglobin (HbCO) solutions of various concentrations have been measured at room temperature, with pure water...Full Text Available
OBJECTIVES: This article uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies of residential magnetic field...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
The magnetic properties of as-grown Ga1-xMnxAs have been investigated by the systematic temperature and magnetic field dependent soft x-ray magnetic circular dichroism (XMCD) measurements in the Mn L2,3 absorption edge region. The XMCD intensity at high temperatures obeys the Curie-Weiss law, but residual spin magnetic moment appears already around 100 K, significantly above Curie temperature (Tc), suggesting that short-range ferromagnetic correlations are developed significantly above Tc. The high-field magnetic susceptibility becomes T-independent below TC, indicating that the AF interaction between the substitutional Mn (Mnsub and interstitial Mn (Mnint) ions, which becomes strong as the Mn concentration x increases, exists and that the amount of the Mnint affects Tc. The present experimental findings should give valuable insight into the inhomogeneous ...
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
An in-plane uniaxial magnetic anisotropy has been observed in thin Co films normally deposited onto obliquely sputtered Ta and Pt underlayers. Associated with this anisotropy is an augmented easy axis coercivity. The in-plane easy axis is, in most cases, perpendicular to the incident deposition plane. Microstructural results indicate that grains are well connected along the magnetic easy axis but are separated by long continuous voids along the hard axis, which is ascribed to a geometric shadowing effect due to the oblique incidence deposition of the underlayer. Hence, the magnetic anisotropy mimics the film growth anisotropy. It is therefore believed that the observed magnetic properties are due to magnetostatic shape anisotropy effects. In-plane coercivity and anisotropy field are shown to increase with underlayer deposition angle, underlayer thickness and magnetic layer ...
A considerable amount of chemical knowledge of marine sediments has been acquired in recent years but has not yet been utilized by paleomagnetists. On the other hand, geochemists are often unaware of the usefulness of numerous magnetic techniques. In this review we try to bridge this gap, and in particular, we outline many of the chemical and magnetic principles that should allow paleomagnetists to better identify and undertand chemical changes that affect the magnetic properties of marine sediments. The chemical principles include those for distinguishing the four major sources of sediments (continental, biological, authigenic/hydrogenous, volcanic/hydrothermal) from one another by determining elemental abundance distributions, as well as for investigating the stabilities of mineral phases relative to changes in pE and pH. The magnetic principles include the effects of authigenesis and diagenesis on ...
ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available
Major breakthroughs have recently been reported that can help overcome two inherent drawbacks of NMR: the lack of sensitivity and the limited memory of longitudinal magnetization. Dynamic nuclear polarization...Full Text Available
Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available
OBJECTIVES: To appraise epidemiological evidence of the purported association between residential exposure to power frequency magnetic fields and adult cancers. METHODS: Literature review and epidemiological...Full Text Available
Epidemiologic research concerning electric and magnetic fields in relation to cancer has focused on the potential etiologic roles of residential exposure on childhood cancer and occupational exposure...Full Text Available
Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available
The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load ...
A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available
OBJECTIVES--This case cohort study examines whether there is an association between exposure to electric and magnetic fields and suicide in a population of 21,744 male electrical utility workers from...Full Text Available
Name U.S. Geological Survey A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal Field, Nevada: A Web Site for Distribution of Data by U. S. Geological Survey &...
A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.
... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...
The read/write characteristics for perpendicular magnetic recording media of focused-ion-beam (FIB)-etched recording heads were investigated. It was found that the trailing edge of an FIB-etched head produces a higher gradient in the magnetic field perpendicular to the medium than a head which has not been etched. The signal-to-noise ratio of the medium increased with the FIB-etched write gap. A high-Bs and thin pole increased the magnetic field's gradient in the perpendicular direction, resulting in excellent read/write characteristics.
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.
The paramagnetic susceptibility of single crystals of dysprosium-yttirum alloys is measured in the basal plane and along the hexagonal axis. It is shown that the susceptibility of the alloys obeys the Curie-Weiss law, the effective magnetic moments allong the different directions being the same and the paramagnetic Curie temperatures being different. The difference between the paramagnetic Curie temperatures in the basal plane and along the hexagonal axis is independent of the dysprosium concentration in the alloy. As a comparison with the theoretical models of magnetic anisotropy shows, this is an indication that the magnetic anisotropy of dysprosium - yttrium alloys is of a single-ion nature.
A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.
This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.
The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).
The a.c. susceptibility and high field magnetization of TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} compounds were investigated up to 140 kOe. The (T, x) magnetic phase diagrams were determined. For both systems, an increase in the Pd content causes a decrease in the Neel temperature and changes the magnetization curves. (orig.)
The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.
The effect of elastic and plastic strains on the magnetic properties of ferrite-pearlite steels has been studied. It has been shown that the sensitivity to elastic-tensile and bending strains is four to five times greater for remnant magnetization than for coercive force. In order to determine the degree of cold plastic deformation of high-carbon steels, a two-parametric testing technique based on the use of remnant magnetization and coercive force was suggested. An MMT-2 device was recommended for measurement of the required parameters.
The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).
An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.
The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.
... fields, materials can be subjected to energy densities exceeding those realized in high explosives, a fact which forms the basis for magnetic forming ...
The results of the investigations show that magnetic treatment is a quite practical and effective method of intensifying certain technological processes in the coking industry. Magnetic treatment was utilized for improving the production of ammonium sulfate, refining of the naphthalene fraction, removal of sludge from wash oil in the benzol division, and the treatment of tar before fractionation. 2 references, 3 tables.
The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.
High-spin states in {sup 202}Pb and {sup 203}Pb have been investigated by in-beam {gamma}-ray spectroscopy following the reaction {sup 198}Pt({sup 9}Be,xn). A search for magnetic rotational bands in these isotopes confirmed one of the two bands previously assigned to {sup 202}Pb and revealed a new band in this isotope. No evidence for magnetic rotation has been found in {sup 203}Pb. (orig.)
Plasma confinement by permanent magnets has been studied. An analytic formula for the field of a single bar magnet has been obtained. Generalization to various configurations of multidipole fields has also been found. Any two-dimensional field may now be completely described by a simple function of complex variables in closed form. Vector potential has also been obtained by integrating over a prescribed Riemann surface. The confinement of plasma by multidipole fields then becomes obvious through conservation principles.
Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.
An alternative and graphical representation of the magnetic moment and the effective paramagnetic moment for polycrystalline Ce compounds with tetragonal site symmetry is described. The reduced moments can be calculated by means of standard perturbation theory. The calculated values deduced from the ground states of CeCu_2Si_2, CeRu_2Si_2, and CePd_2Si_2 polycrystals are compared with experimental magnetic moments.
Measurement of the magnetic susceptibility of powder samples of heavy rare-earth (Tb, Dy, Ho, Er, Tm and Yb) tungstates have been reported in the temperature range 300 to 900 K. Curie-Weiss law behaviour has been observed for all samples. The Curie constant, paramagnetic Curie temperature and magneton number for the magnetic ions have also been evaluated for each material. (author).
Results of experimental researches of impurity level crystals Fe1-xCoxSi are presented in this article. Magnetic properties in a temperature range up to T {<=} 1000 K are analyzed. It was established that with Co impurities increasing origin of magnetic ordering exists at low temperatures. At high temperatures a high temperature maximum of susceptibility of nominally pure iron monosilicide crystal is observed.
This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.
We report on solid solution CePd_2_-_xMn_xSi_2 which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.)).
We report on solid solution CePd[sub 2-x]Mn[sub x]Si[sub 2] which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.))
Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)
The gauge-invariant correlation function for the Yang-Mills field strengths is shown to admit a symmetric decomposition into electric and magnetic components. The spectral weights are seen to obey a sum rule of the superconvergence type, owing to asymptotic freedom. The close relation between the dielectric function, electric-magnetic duality, and the algebra of generalized Chern-Simons charges is illustrated for the linearized Yang-Mills-Higgs system.
The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).
Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...
Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...
In this letter we report a clear and unambiguous observation of the out-of-plane quadrupole magnetic field suggested by numerical simulations in the reconnecting current sheet in the Magnetic Reconnection Experiment (MRX). Measurements show that the Hall effect is large in collisionless regime and becomes small as the collisionality increases, indicating that the Hall effect plays an important role in collisionless reconnection.
Annealing of magnetostrictive Metglas foils, subsequently incorporated into laminated Metglas/Pb(Zr, Ti)O3 magnetoelectric (ME) composites, is shown to result in improved magnetic properties, as well as ME coefficients. Annealing of the foils at 350 ?C resulted in partial crystallization, without oxidation or magnetic cluster formation that would reduce the magnetization. Laminate composites made with these annealed Metglas foils had improved ME coefficients.
It is shown that recuperator in which the thermal energy of particles is transformed into electric oue under drift in crossed fields is naturally coupled with dragontype magnetic confinement system, so the recuperation process can be initiated in the dragon magnetic field. A number of questions occuring under analysis of recuperator-dragon system is considered, including the dynamics of particle transfer to the recuperator, the share of particles entering the recuperator, the effect of rotational transform and the recuperation efficiency.
Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)
The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.
Here, we consider a recent paper concerned with magnetic braking by induced currents (Ireson and Twidle 2008 Eur. J. Phys. 29 745-51). Our objective is to elucidate why measurement of speed in which a magnet is dropped through a non-ferromagnetic conductive tube depends on its geometry in a non-monotonic way, which was not clearly explained by the authors. (letters and comments)
Although a large number of studies on effects of magnetic fields on living organisms was reported, no definite results were obtained in many cases because the related conditions are non-uniform and uncertain, such that the uniform magnetic space is smaller than test samples, and temperature control is insufficient. Therefore, the present study developed a microorganism cultivation system that is applied with a 7-T superconducting magnet. This system has the following features: it generates homogeneous magnetic fields of 0.5 to 7 T {plus_minus} 0.5% in the space with a diameter of 100 mm and a length of 200 mm in a normal temperature bore (with a diameter of 160 mm); it can cultivate microorganisms aerobically at temperatures of 10 to 70{degree}C {plus_minus} 0.1{degree}C; it can perform the cultivation simultaneously with a control cultivation in a small magnetic field weaker than ...
We present a formulation of ab initio electronic structure calculations in a finite magnetic field, which retains the simplicity and efficiency of techniques widely used in first principles molecular dynamics simulations, based on plane-wave basis sets and Fourier transforms. In addition we discuss results obtained with this method for the energy spectrum of interacting electrons in quantum wells, and for the electronic properties of dense fluid deuterium in a uniform magnetic field.
A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).
A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).
Recent advances in nanoscience have raised interest in the minimum bit size required for classical information storage. This bit size is determined by the necessity for bistability with suppressed quantum tunnelling and energy barriers that exceed ambient temperatures. In the case of magnetic information storage, much attention has centred on molecular magnets with bits consisting of about 100 atoms, magnetic uniaxial anisotropy energy barriers of about 50?K and very slow relaxation at low temperatures. Here, we draw attention to the remarkable magnetic properties of some transition-metal dimers, which have energy barriers approaching 500?K with only two atoms. The spin dynamics of these ultrasmall nanomagnets is strongly affected by a Berry phase, which arises from quasi-degen...
Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.
Nanocrystalline MnFe"2O"4 ferrite was prepared by using autocombustion technique (flash). The microstructure and magnetic properties are studied. The results of XRD and TEM clarified that, this ferrite is nanosized with particle size (39 nm). Magnetic measurements showed a ferromagnetic behavior with T"C = 613 K, the saturation magnetization M"s = 13.71 emu/g, remanent magnetization M"r = 0.1694 emu/g and, coercivity H"c = 25.6 Oe. Natural material, egg white used as an aqueous medium to extend prepare nanoparticles better than other chemical interesting materials.
Magnetic refrigeration uses the temperature- and field-dependence of the entropy of some magnetic materials to accomplish cooling. Because of the intrinsically high efficiency of the magnetization and demagnetization process and because of the potential for excellent heat transfer between solids and fluids, magnetic refrigerators promise to have higher efficiency than existing gas-cycle refrigerators. Many ground-based and space-based applications could benefit significantly from the cost savings implied by higher efficiency. Other attributes of these devices are high reliability and low volume and mass per unit cooling power. The development of these refrigerators is underway at several places around the world, including the Los Alamos National Laboratory. The progress to date has been encouraging but some problems have been clearly identified. The arguments for high efficiency and the problems that ...
Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is ...
We derive the exchange currents of pseudoscalar, vector, and scalar mesons from Feynman diagrams, and use them to calculate the magnetic form factors of nucleon and ?(1232). The magnetic moments and electromagnetic radii are obtained by using those form factors and the parameters determined from the masses of nucleon and ?(1232). We find the magnetic moments and electromagnetic radii of nucleon and ?(1232) can be produced very well in the extended Goldstone-Boson-exchange model in which all of pseudoscalar, vector, and scalar meson nonet are included. The magnetic moments of ?(1232) are closer to experiment values and results from lattice calculation than the results obtained by the model without other mesons except for pion and sigma.
The switching behavior of magnetic patterns prepared by ion irradiation was investigated. Co/Pt multilayers with perpendicular anisotropy and large out-of-plane coercivities 5-6 kOe were grown on electron transparent SiN windows. Regularly spaced 1 micron sized regions, were magnetically pattered via ion beam irradiation through a stencil mask. Lorentz TEM was used to observe in-situ magnetization reversal processes of irradiated regions under well-defined applied magnetic fields. When the in-plane field was increased, domain wall motion was observed, resulting in the alignment of the patterns with the direction of the applied field. The switching mechanism of the in-plane patterns was by domain wall motion.
RHIC 8 cm aperture dipole magnets and quadrupole cold masses are being built for Brookhaven National Laboratory (BNL) by Northrop Grumman Corporation at a production rate of one dipole magnet and two quadrupole cold masses per day. This work was preceded by a lengthy Technology Transfer effort which is described elsewhere. This paper describes the tooling which is being used for the construction effort, the production operations at each workstation, and also the use of trend plots of critical construction parameters as a tool for monitoring performance in production. A report on the improvements to production labor since the start of the programs is also provided. The magnet and cold mass designs, and magnetic test results are described in more detail in a separate paper.
This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).
The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...
Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.
Magnetic properties of layer ferromagnets against the thickness are investigated. Two new compounds served for studies: Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1. The Moessbauer effect and the magnetic susceptibility measurements were applied in the experiment. The Faraday method was used in magnetic measurements in fields from 1 to 9,5 kOe. The results of Moessbauer measurements show that temperature dependence of the spectra is typical for compounds with superparamagnetic properties. The magnetic fields Hsub(n) on Fe"5"7 nuclei in Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1 are similar and equal to 520+-10 kOe. Therefore it may be concluded that relaxation times of nuclear spins in these compounds are equal or close to each other. The lines of quadrupole splitting appear in spectra together at 20 K. The results of magnetic ...
We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to saturate the ...
The results of x-ray diffraction, dc magnetization, and 61Ni Moessbauer spectroscopy studies of the ternary arsenide CrNiAs are reported. This compound crystallizes in the orthorhombic Fe2P-type structure (space group P6-bar2m) with the lattice parameters a 6.1128(2) A and c = 3.6585(1) A. CrNiAs is a mean-field ferromagnet with Curie temperature TC = 171.9(1) K and the critical exponents ? 0.514(18), ? = 1.010(16), and ? = 2.922(10). The temperature dependence of the magnetic susceptibility above TC follows the modified Curie-Weiss law with a paramagnetic Curie temperature of 176.0(3) K and effective magnetic moment per transition metal atom of 2.42(1) ?B. The magnetic moment per formula unit at 4.2 K is found to be 1.114(33) ?B. The hyperfine magnetic field at 61Ni nuclei at 4.2 K of 41.5(1.0) kOe implies that the Ni atoms carry a magnetic moment of 0.15(3) ...
Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.
The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were ...
DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque on the ...
DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the crystal field torque ...
In this review, we show how advances in the theory of magnetic pseudodifferential operators (magnetic $\\Psi$DO) can be put to good use in space-adiabatic perturbation theory (SAPT). As a particular example, we extend results of [PST03] to a more general class of magnetic fields: we consider a single particle moving in a periodic potential which is subjectd to a weak and slowly-varying electromagnetic field. In addition to the semiclassical parameter $\\eps \\ll 1$ which quantifies the separation of spatial scales, we explore the influence of additional parameters that allow us to selectively switch off the magnetic field. We find that even in the case of magnetic fields with components in $C_b^{\\infty}(\\R^d)$, e. g. for constant magnetic fields, the results of Panati, Spohn and Teufel hold, i.e. to each isolated family of Bloch bands, there exists an ...
Hereditary hemorrhagic telangiectasia (Osler-Rendu-Weber disease) is a genetic disorder with autosomal dominance, variable penetrance, and an estimated prevalence of 1/10,000 inhabitants in France. Diagnosis is based on clinical criteria including epistaxis, telangiectasia, visceral manifestations, and familial occurrence. Pulmonary arteriovenous malformations, present in 15-33% of patients, are its primary visceral complications. The disease may be revealed by infectious and ischemic neurological manifestations due to paradoxical embolism. The high frequency of neurologic complications even in asymptomatic patients justifies systematic screening for pulmonary arteriovenous malformations. Treatment of these malformations is based on percutaneous transcatheter coil embolization of the feeding artery. Pulmonary arterial hypertension is rare in this disease. It may be due to systemic arteriovenous shunting in the liver, which increases cardiac output, or be similar to ...
Inductive electromagnetic launchers, or coilguns, use discrete solenoidal coils to accelerate a coaxial conductive armature. To date, Sandia has been using an internally developed code, SLINGSHOT, as a point-mass lumped circuit element simulation tool for modeling coilgun behavior for design and verification purposes. This code has shortcomings in terms of accurately modeling gun performance under stressful electromagnetic propulsion environments. To correct for these limitations, it was decided to attempt to closely couple two Sandia simulation codes, Xyce and ALEGRA, to develop a more rigorous simulation capability for demanding launch applications. This report summarizes the modifications made to each respective code and the path forward to completing interfacing between them.
A series of modifications which increased the capacity of Canadian Electrolytic Zinc's Valleyfield plant from 220,000 MT/year to 260,000 MT/year during the last decade is discussed, combined with an an overview of the plant's operations. The modifications included modernisation of the waste disposal methods and facilities, such as a new high-density sludge wastewater treatment process, a new process to remove selenium from weak acid solutions and the jarofix process. Roasting capacity also has been improved by recent investments in new cooling coils, rebricking, oxygen enrichment and process automation. In addition to increases in refining capacity, the improvements also enabled the company to minimize its impact on the environment and the community.
The use of POE solid polymer electrolytes in negative lithium electrode batteries allows to reach energy density values close to 150 Wh/kg. The functioning of Li/POE/V{sub 2}O{sub 5} elements has been studied on small capacity elementary cells (about 26 mAh) and the results obtained were confirmed using coiled elements of 1.4 to 1.8 Ah capacity. This work has been carried out for Bollore Technologies (BT) and Electricite de France (EdF) companies. (J.S.)
TIMETAL LCB was introduced more than 10 years ago targeting automotive suspension spring applications. The alloy development aim was to use a low-cost formulation by selecting less expensive raw materials than typical beta titanium alloys. Following the first successful application of TIMETAL LCB suspension springs to series production vehicles, the 2000 Volkswagen Lupo FSI, the springs have been used for Ferrari Challenge Stradale since 2003. The most recent development effort was focused on the generation of metallurgical and mechanical service data for the alloy, and the implementation of efficient low cost processing of coils. This paper will introduce various properties of TIMETAL LCB products that can be useful in the design and the consideration of spring applications. Recent progress in the processing of TIMETAL LCB will also be introduced and discussed.
Serious complications due to coronary artery fistulae have been described. Most authors recommend early intervention at the time of diagnosis. We present a case of a fistula originating from a dilated left coronary artery and draining into the right atrium, which was diagnosed prenatally by color Doppler echocardiography. During pregnancy, the echocardiographic findings remained unchanged, and there were no signs of heart failure. After birth, the fistula was confirmed by angiography. Additionally, a persistent left superior vena cava draining into the coronary sinus and a very small ventricular septal defect were detected. The fistula was closed successfully by transcatheter coil embolization. At 17 months old the child was in good clinical condition. Prenatal diagnosis of coronary artery fistulae may be possible and may improve perinatal management and outcome. PMID:12047543
Premature Failure of a Riata Defibrillator Lead. A 63-year-old woman with a St. Jude Medical Riata 1570 right ventricular lead complained of intermittent hiccups 2 months after implant. Interrogation revealed elevated pacing threshold and diaphragmatic stimulation. Pacing and shock lead impedances remained stable. No inappropriate sensing was noted. Fluoroscopic examination of the lead revealed a thin radio-opaque wire seen between the 2 defibrillator coils away from the main body of the lead. After extraction, a tear in the insulation of the lead was noted allowing the inner wire to protrude. This case illustrates a novel mechanism of insulation failure without inappropriate sensing or impedance change.-(J Cardiovasc Electrophysiol, Vol. 22, pp. 1070-1072, September 2011)
Multiple receivers can be utilized to enhance the spatiotemporal resolution of MRI by employing the parallel imaging technique. Previously, we have reported the L-curve Tikhonov regularization technique to mitigate noise amplification resulting from the geometrical correlations between channels in a coil array. Nevertheless, one major disadvantage of regularized image reconstruction is lengthy computational time in regularization parameter estimation. At a fixed noise level, L-curve regularization parameter estimation was also found not to be robust across repetitive measurements, particularly for low signal-to-noise ratio (SNR) acquisitions. Here we report a computationally efficient and robust method to estimate the regularization parameter by partitioning the variance of the noise-white...
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was ...
A comparative study on the interaction of (PEG-co-P(FA/SC)-co-PEG) triblock copolymer with bovine and human insulins was carried out using isothermal titration calorimetry (ITC), circular dichroism (CD), and fluorescence spectroscopy. ITC data show that the copolymer has a low affinity for both proteins, with an association constant of about 7?9?103?M ?1. Results also show that binding is enthalpically driven, and disfavored by conformational entropy. CD spectroscopy studies reveal a small increase in the helical content and a decrease in ?-structure as well as random coil in both proteins. Acrylamide quenching experiments display reduced accessibility of tyrosines, while intrinsic fluorescence spectra show lower tyrosine emission. Furthermore, thermal unfolding experiments, studied by far...
The alpha-particle confinement of future D-T experiments at JET can be severely degraded by Global Alfven Eigenmodes (AE). Scenarios for the excitation of Alfven Eigenmodes in usual (e.g. D-D) plasmas are proposed, which provide a MHD diagnostic and allow the study of the transport of super-Alfvenic ions. Active studies with separate control of TAE amplitude and energetic particle destabilization, measuring the plasma response, give more information than passive studies, in particular concerning the damping mechanisms. The TAE excitation can be achieved by means of the saddle coil and the ICRH antenna. The experimental method is introduced together with a theoretical model for RF excitation. (authors). 6 refs., 3 figs.
In order to suppress resonance vibrations of a rotor-shaft of rotating machinery, a rotor-shaft system elastically supported by ball bearings which are installed in electromagnetic actuators are proposed and the design method of some compensatory circuits in the controller to control the electromagnetic actuators in the system are explained. These actuators are controlled by the analog PID (proportional, integral, and derivative) controller. The compensation for nonlinearity of electromagnetic force, the negative stiffness of electromagnet, and the time lag of the coil current are discussed and the effective control circuits are proposed. The rotor-shaft system is replaced by the equivalent two-degree-of-freedom system and both impulse and frequency responses are numerically simulated for several parameters of PD-controller gain. By applying the principle of dynamic absorbers, optimum parameters are calculated. The gains of the control circuit are adjusted to give ...
This paper describes research and development presently being conducted on oil-fired space and tap water heating systems by the Advanced Combustion Technology Group, CCRL/ERL/CANMET, in Ottawa, Canada. The presentation will focus on R&D activities at CCRL in support of the Canadian Oil Heat Association (COHA) and of the energy policy initiatives of Natural Resources Canada. Progress will be reported on activities to develop suitable oil-fired integrated systems to satisfy the low energy demands of new homes. The utilization of fuzzy logic-based control heating systems including fan coils for a complete range of old and new North American housing will be discussed. Additional activities to be discussed in the presentation will relate to the development of appropriate seasonal efficiency standards for complex integrated space/water heating systems, as well as an evaluation of alternative sidewall venting technologies and their implications for seasonal energy ...
Using the full potential linearized augmented plane wave (FLAPW) method, the magnetic properties of two-dimensional Ru and Rh monolayers (MLs) on a NiAl(001) surface have been investigated. It has been found that free standing one monolayer Ru and Rh films have ferromagnetic ground state with magnetic moments of 2.21 and 1.48 #mu#_B, respectively. The ferromagnetism is still observed even on a Ni terminated NiAl(001) surface, while no magnetic state is found on an Al terminated surface. The calculated magnetic moments of Ru and Rh atoms are 1.56 and 0.88 #mu#_B, respectively. In addition, an induced magnetic moment in surface Ni is observed. It has been found that the free standing Ru film has perpendicular magnetization to the film surface with a magnetocrystalline anisotropy (MCA) energy of 0.66 meV/atom, while an in-plane MCA energy of 0.37 meV/atom is ...
This report summarizes the results and activities funded by this three-year award. The principal goal of this project was to determine the thermal conductivity in clusters of galaxies. Intracluster plasmas possess chaotic magnetic fields. Since charged particles are constrained to move primarily along magnetic field lines, the topology of intracluster magnetic fields slows particle diffusion relative to the non-magnetized case, thereby reducing the thermal conductivity. Our first approach to this problem was to employ the static-magnetic-field approximation. In reality, intracluster magnetic field lines are constantly moving, since they are advected by turbulent intracluster motions. The turbulent velocities, however, are much smaller than the rapid speeds of thermal electrons, which make the dominant contribution to the thermal conductivity. In the static-field ...
Experimental investigations are presented which demonstrate that the weak ferromagnets are special materials of a larger group of magnets which exhibit two magnetic ordering structures. In weak ferromagnets the main order is antiferromagnetic with a small ferromagnetic component existing in addition. On the other hand, materials in which other combinations of the two basic ordering structures coexist are also known. Common to all these non-collinear spin structures is that the moment components of the two magnetic structures are orthogonal. In the weak ferromagnets this orthogonality manifests already in the paramagnetic phase as a crossover from an isotropic to an anisotropic susceptibility with respect to the applied magnetic field: at high temperatures the antiferromagnetic Curie-Weiss law of the total moment is observed while for T->Tc crossover to a second Curie-Weiss law due to the weak ...
In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is employed in the driving region to quantify the magnitude of the ...
The term ``dynamo'' means different things to the laboratory fusion plasma and astrophysical plasma communities. To alleviate the resulting confusion and to facilitate interdisciplinary progress, we pinpoint conceptual differences and similarities between laboratory plasma dynamos and astrophysical dynamos. We can divide dynamos into three types: 1. magnetically dominated helical dynamos which sustain a large scale magnetic field against resistive decay and drive the magnetic geometry toward the lowest energy state, 2. flow-driven helical dynamos which amplify or sustain large scale magnetic fields in an otherwise turbulent flow, and 3. flow-driven nonhelical dynamos which amplify fields on scales at or below the driving turbulence. We discuss how all three types occur in astrophysics whereas plasma confinement device dynamos are of the first type. Type 3 dynamos requires no ...
The LHC magnet tests operation team developed various innovative techniques, particularly since early 2004, to complete the superconductor magnet tests by Feb. 2007. Overall and cryogenic priority handling, rapid on-bench thermal cycling, rule-based goodness evaluation on round-the-clock basis, multiple, mashed web systems are some of these techniques applied with rigour for successful tests completion in time. This paper highlights these operation empowerment tools which had a pivotal role for success. A priority handling method was put in place to enable maximum throughput from twelve test benches, having many different constraints. For the cryogenics infrastructure, it implied judicious allocation of limited resources to the benches. Rapid On-Bench Thermal Cycle was a key strategy to accelerate magnets tests throughput, saving time and simplifying logistics. First level magnet appraisal was developed ...
Magnetic imaging in the transmission electron microscope (TEM) has been used to examine submicron elements with the aim of discovering down to what element size complex domain patterns can form. The elements were squares, circles, triangles, and pentagons in the size range 100{endash}500 nm and were made from 36 nm Co films or 8 nm Ni{sub 80}Fe{sub 20} (NiFe) with in-plane magnetization. The magnetic domain structures in these elements were imaged at high resolution using the differential phase contrast imaging mode in a TEM. Nonuniform magnetization structures were seen in the images. Vortices were present at remanence in all shapes of 36-nm-thick Co elements down to 100 nm size and in circular NiFe elements down to 116 nm diameter. Triangular NiFe elements did not have a vortex state at remanence, instead the magnetization curved round within the element but did not achieve ...
Ho{sub 2}CuTiO{sub 6} double pervoskite is synthesized by solid state reaction method and the phase formation was confirmed by X-ray diffraction. Ho{sub 2}CuTiO{sub 6} crystallizes in space group P63 cm and are isostructural in AMnO{sub 3} structure. We have investigated the effect of the presence of a magnetic ion (Ho{sup 3+}{approx}10.4{mu}{sub B}) in Ho{sub 2}CuTiO{sub 6}, on the magnetic properties, compared to that of an isostructural double perovskite containing Y-ion (non-magnetic), i.e., Y{sub 2}CuTiO{sub 6}. Magnetization measurements on Ho{sub 2}CuTiO{sub 6} showed paramagnetic moment of 0.026{mu}{sub B}/Ho at room temperature in an applied field of 7 T although no saturation is observed at room temperature, whereas, at 5 K, the paramagnetic moment was 0.3{mu}{sub B}/Ho in the same field. Since this compound is non-centrosymmetric, it is of interest to look into the possibility of realizing ...
We present an x-ray magnetic circular dichroism (XMCD) study performed on both Ho{sub 6}Fe{sub 23} and Y{sub 6}Fe{sub 23} compounds as a function of the temperature. The combined analysis of both Fe K-edge and Ho L{sub 2,3}-edge XMCD spectra recorded through the magnetic compensation transition allows us to disentangle the thermal dependence of both Fe and Ho magnetic moments in Ho{sub 6}Fe{sub 23}. In addition, contributions from Ho ions to the Fe K-edge XMCD signals and, conversely, from Fe ions to the Ho L{sub 2,3}-edge XMCD spectra have been clearly identified. These extra contributions, arising from the strong Fe(3d)-Ho(5d) hybridization, have been isolated from the spectra and correlated with the magnetic state of both Ho and Fe ions surrounding the absorbing site. The influence of these contributions to the values of the orbital and spin moments derived by using sum rule analysis is also shown.
Holmium doped barium based hexaferrites BaFe12-2xHo2xO19 with (x=0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho^3^+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (Ms), remanent magnetization (Mr) and coercivity (Hc) were observed by changing Ho^3^+ content in BaFe12-2xH...
Holmium doped barium based hexaferrites BaFe_1_2_-_2_xHo_2_xO_1_9 with (x = 0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho"3"+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (M_s), remanent magnetization (M_r) and coercivity (H_c) were observed by changing Ho"3"+ content in BaFe_1_2_-_2_xHo_2_xO_1_9 ferrites. Coercivity showed a maximum value of 2230 Oe for (x = ...
The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the observations can be explained by a thin ...
The magnetically fluidized bed (MFB) was used as the reactor in a novel semidry flue gas desulfurization (FGD) process to achieve high desulfurization efficiency. Experiments in a laboratory-scale apparatus were conducted to reveal the effects of approach to adiabatic saturation temperature, Ca/S molar ratio and applied magnetic field intensity on SO(2) removal. Results showed that SO(2) removal efficiency can be obviously enhanced by decreasing approach to adiabatic saturation temperature, increasing Ca/S molar ratio, or increasing applied magnetic field intensity. At a magnetic field intensity of 300Oe and a Ca/S molar ratio of 1.0, the desulfurization efficiency (excluding desulfurization efficiency in the fabric filter) was over 80%, while spent sorbent appeared in the form of dry powder. With the SEM, XRD and EDX research, it can be found that the increase of DC magnetic field ...
Gantries in the proton/carbon cancer therapy machines represent the major cost and are of the largest size. This report explains a new way to the gantry design. The size and cost of the gantries are reduced and their use is simplified by using the fixed magnetic field. The ''new'' gantry is made of a very large momentum acceptance non-scaling Fixed Field Alternating Gradient (FFAG) quarter and half arc beam lines. The gantry is made of combined function magnets with a very strong focusing and small dispersion function. Additional magnets with a fast response are required to allow adjustments of the beam position for different energies at the beginning of the gantry. Additional strong focusing magnets following the gantry have also to be adjustable to provide required spot size and radial scanning above the patients. The fixed field combined function ...
The sharp, temperature induced, continuous valence transition in EuPd/sub 2/Si/sub 2/ is drastically changed by doping with Sn at the Si site up to 5 at.%. Only a first order valence transition occurs for a 3% Sn doped sample and the 2/sup +/ component which survives the valence transition orders magnetically at 4.2 K. No valence transition at all occurs for a 5% Sn doped sample right up to 1.9 K and magnetic ordering sets in around 30 K.
Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.
A total of 50 000 tonnes of low-carbon steel sheet has been ordered for the LHC main magnets. After three years of production, about 10 000 tonnes of steel sheet have been produced by Cockerill-Sambre Groupe Usinor. This paper gives a summary of the manufacturing process and improvements implemented as well as an overview of the difficulties encountered during this production. Preliminary statistics obtained for the mechanical and magnetic steel properties are presented. (6 refs).
Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.
A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.
CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.
We present the synthesis, magnetic and UV spectrometry of NiZn-ferrite nanofiber. The single phase of spinel ferrite was obtained at 600 {sup o}C. The NiZn-ferrite fibers fabricated by an electrospinning process were formed as a polygonal grain growth with firing temperature in fiber matrix. It appeared that the saturation magnetization (M{sub S}) of NiZn-ferrite nanofiber was dependent on Ni/Zn molar ratio which is similar to that of the inverse spinel ferrites. The NiZn-ferrite fibers showed good DNA adsorption efficiency that can be modified and utilized for DNA separation with magnetic nanofiber as a novel material in clinical applications.
The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters. (orig.)
The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters.
The DC magnetic susceptibility of the REBa_2F_7 compounds was measured by a SQUID magnetometer in the temperature range 5-300 K. Except for Eu, the other compounds show either Curie law or Curie-Weiss law with relatively small values of paramagnetic Curie temperature, #theta#_p, with effective magnetic moments in the range expected of electronic ground state of the trivalent rare earth ion with appropriate J value. The behaviour of Eu is complex. (orig.).
The magnetic field strengths of most millisecond pulsars(MSP) are about $10^{8-9}$ Gauss. The accretion induced magnetic field evolution scenario here concludes that the field decay is invesely related to the accreted mass and the minimum field or bottom field stops at about $10^{8}$ Gauss if accreted with the Eddington accretion rate, which is proportionally related with the accretion rate as $\\dot{M}^{1/2}$. The possibility of the low field $\\sim 10^{7}$ Gauss MSPs has been proposed for the future radio observation.
The problem of thermal instability of compressible, electrically conducting couple-stress fluids in the presence of a uniform magnetic field is considered. Following the linearized stability theory and normal mode analysis, the dispersion relation is obtained. For stationary convection, the compressibility, couple-stress, and magnetic field postpone the onset of convection. Graphs have been plotted by giving numerical values of the parameters to depict the stability characteristics. The principle of exchange of stabilities is found to be satisfied. The magnetic field introduces oscillatory modes in the system that were non-existent in its absence. The case of overstability is also studied wherein a sufficient condition for the non-existence of overstability is obtained. (orig.)
Magnetic behavior in three compounds RTa{sub 3}O{sub 9} (R = Nd, Eu and Ho) with defect-perovskite structures has been investigated by DC magnetic susceptibility. The susceptibility of NdTa{sub 3}O{sub 9} shows strong influence of crystal field. For EuTa{sub 3}O{sub 9} a typical Van Vleck paramagnetism has been observed. HoTa{sub 3}O{sub 9} obeys a Curie-Weiss law above 20 K. (orig.) 8 refs.
The results obtained from the magnetization, specific heat and electrical resistivity measurements on a polycrystalline sample of Pr_2Pd_3Si_5 are reported. The temperature dependence of magnetic susceptibility at low field (0.01 T) exhibits pronounced anomaly below 7 K due to antiferromagnetic ordering. The electrical resistivity and specific heat data also exhibit sharp transition at 6.6 K evidencing the onset of antiferromagnetic order. A fit to the electrical resistivity data below 6 K suggests the presence of an energy gap in magnon spectrum in the ordered state. (author)
Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.
The orbit response matrix (ORM) method [1] is applied to model the Fermilab Booster with parameters such as the BPM gains and rolls, and parameters in the lattice model, including the gradient errors and magnets rolls. We found that the gradients and rolls of the adjacent combined-function magnets were deeply correlated, preventing full determination of the model parameters. Suitable constraints of the parameters were introduced to guarantee an unique, equivalent solution. Simulations show that such solution preserves proper combinations of the adjacent parameters. The result shows that the gradient errors of combined-function magnets are within design limits.
Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.
Two new identical insertion devices have been designed for the Daresbury SRS. They are 2T permanent-magnet multipole wigglers that will provide high flux in the X-ray region. This paper describes the magnetic and mechanical design of the arrays of steel pole pieces and permanent-magnet blocks. Also given is the engineering design of the support structure that will cope with the very large forces present while maintaining high levels of precision in gap setting and parallelism. The engineering design has been fully assessed using finite-element techniques to predict the deflections of critical parts of the structure. These two devices are due to be installed into the SRS by the end of 1998.
The ZnO nanorods were used as a template to fabricate nickel nanoclusters by electrodeposition. The ZnO nanorod arrays act as a nano-semiconductor electrode for depositing metallic and magnetic nickel nanoclusters. The growth sites of Ni nanoclusters could be controlled by adjusting the applied potential. Under -1.15 V the Ni nanoclusters could be grown on the tips of ZnO nanorods. On increasing the potential to be more negative the ZnO nanorods were covered by Ni nanoclusters. The magnetic properties of the electrodeposited Ni nanoclusters also evolved with the applied potentials.
Differentiating characteristics of magnetic confinement systems having externally generated magnetic fields that are open'' are listed and discussed in the light of their several potential advantages for fusion power systems. It is pointed out that at this stage of fusion research high-Q'' (as deduced from long energy confinement times) is not necessarily the most relevant criterion by which to judge the potential of alternate fusion approaches for the economic generation of fusion power. An example is given of a hypothetical open-geometry fusion power system where low-Q operation is essential to meeting one of its main objectives (low neutron power flux).
This paper is devoted to investigate the influences of thermal dispersion and magnetic field on a hot semi-infinite vertical porous plate embedded in a saturated Darcy-Forchheimer-Brinkman porous medium. The coefficient of thermal diffusivity has been assumed to be the sum of the molecular diffusivity and the dynamic diffusivity due to mechanical dispersion. The effects of transverse magnetic field parameter (Hartmann number Ha), Reynolds number Re (different velocities), Prandtl number Pr (different types of fluids) and dispersion parameter on the wall shear stress and the heat transfer rate are discussed.
Borrelia burgdorferi sensu lato genospecies were differentiated by PCR-based sequencing of the borrelial flagellin gene. To evaluate the usefulness of KingFisher"T"M magnetic particle processor in PCR product purification, borrelia PCR products were purified with KingFisher"T"M magnetic particle processor prior to cycle sequencing and the quality of the sequence data received was analyzed. KingFisher was found to offer a rapid and reliable alternative for borrelial PCR product purification.
The baseline design for the SSC High Energy Booster (HEB) has dipole bending magnets with a 50 mm aperture. An analysis of the cryogenic heat load due to A.C. losses generated in the HEB ramp cycle are reported for this magnet. Included in this analysis are losses from superconductor hysteresis, yoke hysteresis, strand eddy currents, and cable eddy currents. The A.C. loss impact of 2.5 {mu}m vs. 6 {mu}m filament conductor is presented. A 60 mm aperture design is also investigated. 8 refs., 3 tabs.
... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...
We present results on searches for exotic particles (relativistic magnetic monopoles and WIMPs) and for UHE neutrinos, obtained with the Baikal neutrino telescope NT200.
Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.
... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...
A shipbuilder is using an electro-magnetic forming system (on loan from NASA) in a development program. " A modification in the design of a metal bending ...
The existence of multipole components in the dipole and quadrupole magnets is one of the factors limiting the beam stability in the RHIC operations. So, a realistic non-linear model is crucial for understanding the beam behavior and to achieve the ultimate performance in RHIC. A procedure is developed to build a non-linear model using the available multipole component data obtained from measurements of RHIC magnets. We first discuss the measurements performed at different stages of manufacturing of the magnets in relation to their current state in RHIC. We then describe the procedure to implement these measurement data into tracking models, including the implementation of the multipole feed down effect due to the beam orbit offset from the magnet center. Finally, the field quality analysis in the RHIC interaction regions (IR) is presented.
The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).
Samples of Fe78B13Si9 (Metglas 2605 TCA) and Fe77Cr2B16Si5 (Metglas 2605 S3A) were exposed to pulsed excimer laser irradiation at repetition rates of 15, 25 and 50Hz. The occurrence of out-of-plane magnetic anisotropy, changes in the average hyperfine magnetic field and width of the hyperfine field distribution were evidenced by transmission Mossbauer spectroscopy. The variation of the recoilless fraction with laser processing parameters was derived from the simultaneous recording of Mossbauer spectra using a stainless steel etalon as a dual absorber. Conclusions on the onset of long-range magnetic order were formulated.
The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).
We report electronic and magnetic structure of arsenic-doped manganese clusters from density-functional theory using generalized gradient approximation for the exchange-correlation energy. We find that arsenic stabilizes manganese clusters, though the ferromagnetic coupling between Mn atoms are found only in Mn$_2$As and Mn$_4$As clusters with magnetic moments 9 $\\mu_B$ and 17 $\\mu_B$, respectively. For all other sizes, $x=$ 3, 5-10, Mn$_x$As clusters show ferrimagnetic coupling. It is suggested that, if grown during the low temperature MBE, the giant magnetic moments due to ferromagnetic coupling in Mn$_2$As and Mn$_4$As clusters could play a role on the ferromagnetism and on the variation observed in the Curie temperature of Mn-doped III-V semiconductors.
The current paper continues the analysis of a completely novel method of fluid manipulation technology in micro-fluidics systems, inspired by nature, namely by the mechanisms found in ciliates. More information on this subject can be found at http://www.hitech-projects.com/euprojects/artic/. In order to simulate the drag forces acting on an array of artificial cilia, we have developed a computer code that is based on fundamental solutions of Stokes flow in a semi-infinite domain. The actuation mechanism consists of a bi-directional rotating excitation magnetic field. The magnetization induced by the magnetic field was calculated in a separate routine based on the Integral Nonlinear Equations Approach with 1D discretization of wire (cilium). Time averaged x-coordinate mass flow rates, strea...
... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...
We investigate the effects of the velocity-dependent force on the magnetic form factors and magnetic moments of odd-Z nuclei. The form factors are calculated with the harmonic-oscillator wavefunctions. It is found that the contributions of the velocity-dependent force manifest themselves in the very large momentum transfer region (q?4 fm-1). In the low and medium q region the contributions of the velocity-dependent force are very small compared with those without this force. However, in the high-q region the contributions of the velocity-dependent force are larger than the normal form factors. The diffraction structures beyond the existing experimental data are found after the contributions of the velocity-dependent force are included. The formula of the correction to the single particle magnetic moment due to the velocity-dependent force is reproduced exactly in the long-wavelength limit (q=0) of the M1 form factor. ...
SOME SCIENTISTS ALLEGE that exposure to electric and magnetic fields generated by electric power delivery systems is responsible for certain cancers (particularly among children), reproductive dysfunction,...Full Text Available
To study the nanoscale electronic order in strongly correlated electron systems and vortex states in high-Tc superconductors in high magnetic fields, we have developed scanning tunneling microscopy (STM) for the 18 T cryocooled superconducting magnet (18T-CSM). The test results of the STM operation in the 18T-CSM at room temperature indicate that our STM has a good atomic resolution up to 18 T when we use the nonmagnetic vibration-isolation table which reduce the vibration noise from the cryocoolers of the 18T-CSM. In this paper, we report on the design of the high-field STM system for large-scale magnets and its performance.
High Cycle Fatigue Initiative Workshop -Active Vibration. Control/Engine. Health Monitoring Session December 10,. 1996. The presentation was titled "Active ...