... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...
A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.
This patent describes an ignition system of an internal combustion engine which consists of: a permanent magnet supported by a rotary member of the engine adapted to rotate in synchronism with a rotary shaft of the engine; a generating coil for generating an electromotive force to produce an electric current as the permanent magnet acts on the generating coil during the rotation of the rotary member; an ignition capacitor charged by the electric current generated by the generating coil; a thyristor caused to turn on by a counter electromotive force generated by the generating coil to thereby cause the ignition capacitor to begin to discharge; and an ignition coil generating a high voltage as the ignition capacitor begins to discharge, to cause a spark discharge to take place in ...
A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted ...
SOME SCIENTISTS ALLEGE that exposure to electric and magnetic fields generated by electric power delivery systems is responsible for certain cancers (particularly among children), reproductive dysfunction,...Full Text Available
Differentiating characteristics of magnetic confinement systems having externally generatedmagnetic fields that are open'' are listed and discussed in the light of their several potential advantages for fusion power systems. It is pointed out that at this stage of fusion research high-Q'' (as deduced from long energy confinement times) is not necessarily the most relevant criterion by which to judge the potential of alternate fusion approaches for the economic generation of fusion power. An example is given of a hypothetical open-geometry fusion power system where low-Q operation is essential to meeting one of its main objectives (low neutron power flux).
In the current wind turbine generation system, there are substantial problems such as the maximum power of the wind turbine cannot be obtained under the fluctuating wind speed, high in cost and low in annual net electricity production (due to mismatch between a generator and a wind turbine). A new wind turbine generator optimized for the wind turbine output is presented in order to solve such problems. This wind turbine generator consists of a permanent magnetgenerator, a reactor and a rectifier, and uses neither a control circuit which requires standby electricity nor a PWM converter having a switching element. By selecting most appropriate combination of the permanent magnetgenerator having multiple windings and the reactor connected in series with each winding, the maximum output of the wind turbine can be obtained ...
MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...
We study the spin dependence of accretion onto rotating Kerr black holes using analytic techniques. In its linear regime, angular momentum transport in MHD turbulent accretion flow involves the generation of radial magnetic field connecting plasma in a differentially rotating flow. We take a first principles approach, highlighting the constraint that limits the generation and amplification of radial magnetic fields, stemming from the transfer of energy from mechanical to magnetic form. Because the energy transferred in magnetic form is ultimately constrained by gravitational potential energy or Killing energy, the spin dependence of the latter allows us to derive spin-dependent constraints on the success of the accreting plasma to expel its angular momentum. We find an inverse relationship between this ability and black hole spin. If this radial ...
A one-dimensional numerical model for the expansion of impact-produced vapor clouds is used to investigate magnetic field generation mechanisms in events such as meteor collisions with the moon. The resulting cloud properties, such as ionization fraction, electrical conductivity, radial expansion velocity, mass density, and energy density are estimated. The model is initiated with the peak shock states and pressure thresholds for incipient and complete vaporization of anorthosite lunar surface materials by iron and GA composition meteorites. The expansion of the spherical gas cloud into a vacuum was traced with a one-dimensional explicit lagrangian hydrodynamic code. The hypervelocity impact plasmas produced are found to be significant in the amplitudes and orientations of the magnetic fields generated. An ambient magnetic field could have been provided by the core dynamo, which ...
The baseline design for the SSC High Energy Booster (HEB) has dipole bending magnets with a 50 mm aperture. An analysis of the cryogenic heat load due to A.C. losses generated in the HEB ramp cycle are reported for this magnet. Included in this analysis are losses from superconductor hysteresis, yoke hysteresis, strand eddy currents, and cable eddy currents. The A.C. loss impact of 2.5 {mu}m vs. 6 {mu}m filament conductor is presented. A 60 mm aperture design is also investigated. 8 refs., 3 tabs.
Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.
Using the experimentally determined cutoff energies of the muon-electron and the pion-electron conversion curves in a tachyon-bradyon model of the electron and the muon, the magnetic moments of these particles have been derived and found to be the Bohr magnetons identically. The tachyons, being bound to the bradyons and unable to drop below the speed of light, cause the bradyons to revolve in an orbit. It is this orbital motion of the charged bradyons that generates the magnetic moments.
Superconducting generators for high power applications have been of interest for a number of years. Superconducting generators using low temperature superconductors (LTS) have been manufactured to produce up to 20 MW of electrical power and have been configured in either synchronous alternators which have an AC output that may be subsequently rectified to produce DC and homopolar generators which produce low voltage DC. Typically these generators require scrupulous attention to vacuum integrity for cryogenic insulation at 4.2K and tend to be somewhat fragile because of extensive thermal and magnetic shields that are not required in conventional power generators. Recently, high purity aluminum composites have been developed for a high power AC generator that is cooled by cryogenic hydrogen at 21K. This aluminum generator ...
In this review, we show how advances in the theory of magnetic pseudodifferential operators (magnetic $\\Psi$DO) can be put to good use in space-adiabatic perturbation theory (SAPT). As a particular example, we extend results of [PST03] to a more general class of magnetic fields: we consider a single particle moving in a periodic potential which is subjectd to a weak and slowly-varying electromagnetic field. In addition to the semiclassical parameter $\\eps \\ll 1$ which quantifies the separation of spatial scales, we explore the influence of additional parameters that allow us to selectively switch off the magnetic field. We find that even in the case of magnetic fields with components in $C_b^{\\infty}(\\R^d)$, e. g. for constant magnetic fields, the results of Panati, Spohn and Teufel hold, i.e. to each isolated family of Bloch bands, there exists an ...
Although a large number of studies on effects of magnetic fields on living organisms was reported, no definite results were obtained in many cases because the related conditions are non-uniform and uncertain, such that the uniform magnetic space is smaller than test samples, and temperature control is insufficient. Therefore, the present study developed a microorganism cultivation system that is applied with a 7-T superconducting magnet. This system has the following features: it generates homogeneous magnetic fields of 0.5 to 7 T {plus_minus} 0.5% in the space with a diameter of 100 mm and a length of 200 mm in a normal temperature bore (with a diameter of 160 mm); it can cultivate microorganisms aerobically at temperatures of 10 to 70{degree}C {plus_minus} 0.1{degree}C; it can perform the cultivation simultaneously with a control cultivation in a small ...
In this article a production method of a magnetorheological suspension composed with silicon steel particles of size 0.1-0.15 mm and 4% silicon content is described. Steel particles were dispersed in a conducting carrier of a by mixture of graphite particles with size 2-5 {mu}m and cedar wood oil. The filling factor of the suspension with the silicon steel particles and with graphite particles amounted to 0.25-0.40. Samples of this suspension were placed in a rectangular vessel with electrodes and used for the investigation of the Hall effect in magnetic field with induction 0-8 T, generated by Bitter-type magnet. A non-linear dependence of Hall voltage on the induction of the applied magnetic field and a hysteresis loop of this voltage in the shape of inclined digit eight were found. The causes of the observed effects is the ordering of silicon steel particles and graphite particles along the side of ...
Magnetic fields appear to be a generic feature of the early universe and are a natural source of secondary CMB non-Gaussianity. In recent years the statistical nature of the stresses of a primordial magnetic field has been well studied. In this paper we confirm and extend these studies at one- and two-point level, and present analytical results for a wide range of power-law spectra. We also consider two non-power law cases of interest: a blue spectrum with an extended damping tail on small scales, which could be generated by the non-linear mixing of density and vorticity; and a red spectrum with a damping tail on large scales. We then briefly consider the CMB impacts that result from such fields. While this paper focuses on the one- and two-point moments, the techniques we employ are designed to ease the analysis of the full bispectra induced by primordial magnetic fields.
We show that the generating function of all amplitudes with N twisted and M untwisted states, i.e. the Reggeon vertex for magnetized branes on R^2 can be computed once the correlator of N non excited twisted states and the corresponding Green function are known and we give an explicit expression as a functional of the these objects
In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.
In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.
A stable, accurate, and efficient implementation of MacCormack's explicit algorithm for the Parabolized Navier-Stokes equations is demonstrated. The familiar problem of decoding the conservative axialflux vector is solved, resulting in accurate, smooth dependent variable profiles through the viscous-layer sonic line. Source terms due to transformation of the parabolized governing equations into the computational plane and the equations into the computational plane and the resulting metric differencing have been identified and eliminated through inclusion of appropriate geometric conservation law terms. Test cases computed include two- and three-dimensional supersonic and hypersonic flow at laminar and turbulent Reynolds numbers. The computed results demonstrate very good agreement with experiment and with solutions of the full Navier-Stokes equations. Computational times required for the MacCormack explicit PNS code are approximately ...
The authors address the question of the limitations on voltage and current transfer to loads in magnetic storage systems utilizing microsecond conduction time plasma opening switches. They propose that the limitation of performance results from neutral atoms that are not entrained into the ionized material that is driven by the magnetic field of the rising generator current. Evidence in support of this proposition is gathered from experiments performed on the Ace-4 and Hawk generators. They set forth a theory to describe the effect of neutrals on the electrical performance of plasma opening switches. The neutral gas is assumed to be present in the region between the moving plasma mass and the generator, primarily in the region in which the plasma is injected initially. The essential elements of the theory are a weak photoionization source to seed the gas with a low concentration of ...
In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is employed in the driving region to quantify ...
This paper describes the design of a high-voltage negative ion source based on a magnetically insulated diode and generating microsecond pulses. Plane an cylindrical cathodes have been tested. The spatial and angular distributions of negative ions in the beam have been measured. The content of negative ions with different masses in the beam are given. The ion current density measured by a Faraday cup was up to 1 A/cm{sup 2} for the radial beam and 30-40 A/cm{sup 2}.
Current multi-scale computational models of ventricular electromechanics describe the full process of cardiac contraction on both the micro- and macro- scales including: the depolarization of cardiac cells, the release of calcium from intracellular stores, tension generation by cardiac myofilaments, and mechanical contraction of the whole heart. Such models are used to reveal basic mechanisms of cardiac contraction as well as the mechanisms of cardiac dysfunction in disease conditions. In this paper, we present a methodology to construct finite element electromechanical models of ventricular contraction with anatomically accurate ventricular geometry based on magnetic resonance and diffusion tensor magnetic resonance imaging of the heart. The electromechanical model couples detailed repres...
Starting with two supersymmetric dual theories, we imagine adding a chiral perturbation that breaks supersymmetry dynamically. At low energy we then get two theories with soft supersymmetry-breaking terms that are generated dynamically. With a canonical K{umlt a}hler potential, some of the scalars of the ``magnetic`` theory typically have negative mass-squared, and the vector-like symmetry is broken. Since for large supersymmetry breaking the ``electric`` theory becomes ordinary QCD, the two theories are then incompatible. For small supersymmetry breaking, if duality still holds, the magnetic theory analysis implies specific patterns of chiral symmetry breaking in supersymmetric QCD with small soft masses.
Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general ...
A new model for short-range isoscalar current in the deuteron and NN system is developed and tested on a variety of isoscalar magnetic observables such as the deuteron magnetic moment, magnetic form factor, and the circular polarization of photons at n"#->#p radiative capture at thermal neutron energies. The model for electromagnetic two-nucleon current proposed in the paper is based on generation of an intermediate dibaryon in the short-range NN interaction. This intermediate dibaryon, in turn, is treated within the new model for intermediate and short-range NN interaction recently proposed by the present authors. The transition current model developed here satisfies the current conservation relation by the construction. Our calculations have demonstrated that the new current model, using only one parameter (with a clear physical meaning), is able to describe, in very good agreement with the ...
Relativistic strongly magnetized winds outflowing from fast-rotating compact objects like millisecond pulsars with surface magnetic fields of $\\sim 10^{15}-10^{16}$ G are plausible sources of cosmological $\\gamma$-ray bursts. In such winds, there are at least three regions where extremely powerful X-ray and $\\gamma$-ray emission may be generated. The first radiating region is the wind photosphere that is at a distance of $\\sim 10^9$ cm from the compact object. The second radiating region is at a distance of $\\sim 10^{13}-10^{14}$ cm. In this region, the striped component of the wind field is transformed into large-amplitude electromagnetic waves. The third radiating region is at a distance of $\\sim 10^{16}-10^{17}$ cm, where deceleration of the wind due to its interaction with an ambient medium becomes important. Radiation from all these regions is considered.
We calculate the quarkonium dissociation rate in the P and CP-odd domains (bubbles) that were possibly created in heavy-ion collisions. In the presence of the magnetic field produced by the valence quarks of colliding ions, parity-odd domains generate electric field. Quarkonium dissociation is the result of quantum tunneling of quark or antiquark through the potential barrier in this electric field. The strength of the electric field in the quarkonium comoving frame depends on the quarkonium velocity with respect to the background magnetic field. We investigate momentum, electric field strength and azimuthal dependence of the dissociation rate. Azimuthal distribution of quarkonia surviving in the electromagnetic field is strongly anisotropic; the form of anisotropy depends on the relation between the electric and magnetic fields and quarkonium momentum. These features can be used to explore the ...
Magnetite nanoparticles with high self-heating capacity and low toxicity characteristics are a promising candidate for cancer hyperthermia treatment. In order to achieve minimum dosage to a patient, magnetic nanoparticles with high heating capacity are needed. In addition, the influence of physiological factors on the heat capacity of a material should be investigated in order to determine the feasibility. In this study, magnetite nanoparticles coated with lauric acid were prepared by co-precipitation of Fe{sup 3+}:Fe{sup 2+} in a ratio of 2:1, 5:3, 3:2, and 4:3, and the pH was controlled using NaOH. Structural and magnetization characterization by means of X-ray diffractometry (XRD) and a superconducting quantum interference device (SQUID) revealed that the main species was Fe{sub 3}O{sub 4} and further showed that most of the nanoparticles exhibited superparamagnetic properties. All of the magnetic nanoparticles showed a ...
Based on a detailed analysis of the inter-relationship in the current, voltage, electromagnetic torque and ratio of the difference between the speed of rotor and the speed of rotary magnetic field to the later in the motor, the root cause was point out, which leads to the protection fuses' failure of the motor in the starting stage, which drives the turbine-generator set to rotate at low speed before its startup. Two solutions to avoid the situation are proposed, too. (authors)
The effect of 50 Hz and 60 Hz (frequencies of current distribution) and 20 kHz to 50 kHz (frequencies of induction cooktop) magnetic interference on implanted pacemakers have been assessed with the present generation of device technology. Sixty patients implanted in 1998 and 1999 with dual chamber pacemakers from 9 different manufacturers were monitored with telemetry while passing through, and standing between a system of two coils. They generated a 50 Hz or a 60 Hz magnetic field at 50 microT. Then, patients used a cooktop at different power. The recordings were made with the standard setting of "medically correct" sensing parameters chosen for the patients. Then pacemakers were reprogrammed to the unipolar mode, with the highest atrial (A) and ventricular (V) sensitivity that did not induce muscular inhibition while moving. Between each exposure (50 Hz, 60 Hz or 20 kHz to 50 kHz), the pacemaker ...
Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.
Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).
The relativistic motion of an electron is numerically analyzed in a tokamak having macroscopic magnetic turbulence. Stochasticity induced by the relativistic motion overwhelms the phase averaging effect, which provides a tokamak with an effective loss mechanism for the avoidance/suppression of runaway electron generation at a major disruption. On the other hand, electrons in the KAM (Kolmogorov-Arnold-Moser) region will be observed as a runaway snake. (author)
The suggestion has been made that stars with collapsing iron cores may be unable to explode, and hence may generate black holes. The situation when the collapsing core is rotating and magnetized is investigated and it is tentatively concluded that these effects make the situation even more conducive to the formation of black holes. (auth)
Here we show that self-propulsion in quantum vacuum may be achieved by rotating or aggregating magneto-electric nano-particles. The back-action follows from changes in momentum of electro-magnetic zero-point fluctuations, generated in magneto-electric materials. This effect may provide new tools for investigation of the quantum nature of our world. It might also serve in the future as a "quantum wheel" to correct satellite orientation in space.
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer ...
Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. Nondestructive flaw detection tests was ...
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were presented as color-coded anatomically-mapped ...
A generic reactor model is used to examine the economic viability of electricity generation by magnetic fusion. The simple model uses components which are representative of those used in previous reactor studies of deuterium-tritium burning tokamaks, stellarators, bumpy tori, reverse field pinches and tandem mirrors. Conservative costing assumptions are made. The generic reactor is not a tokamak but rather it is intended to emphasize what is common to all magnetic fusion reactors. The reactor uses a superconducting toroidal coil set to produce the dominant magnetic field. To this extent it is a less good approximation to systems, such as the reversed field pinch in which the main field is produced by a plasma current. The main output of the study is the cost of electricity as a function of the weight and size of the fusion core - blanket, shield, structure and coils. The model shows that a 1200 MW/sub ...
Electromagnetic fields have been reported to cause a variety of biological effects. It has been hypothesized that many of these phenomena are mediated by a primary effect on the concentration of cytosolic free calcium ((Ca2+)i). We investigated the effects of exposure to electromagnetic fields on (Ca2+)i in HL-60 cells using the Ca2(+)-sensitive fluorescent indicator indo-1. Indo-1-loaded cell samples were exposed to a radiofrequency electromagnetic field, a static magnetic field, and a time-varying magnetic field, which were generated by a magnetic resonance imaging (MRI) unit. We found that a 23-min exposure to all three fields, in combination, induced a significant increase in (Ca2+)i of 31 +/- 8 (SE) nM (P less than 0.01, n = 13) from a basal level of 121 +/- 8 nM. Also, cells exposed to only the time-varying magnetic field had a mean (Ca2+)i that was 34 +/- 10 nM (P less than ...
We study the magnetic braking and viscous damping of differential rotation in incompressible, uniform density stars in general relativity. Differentially rotating stars can support significantly more mass in equilibrium than nonrotating or uniformly rotating stars, according to general relativity. The remnant of a binary neutron star merger or supernova core collapse may produce such a 'hypermassive' neutron star. Although a hypermassive neutron star may be stable on a dynamical time scale, magnetic braking and viscous damping of differential rotation will ultimately alter the equilibrium structure, possibly leading to delayed catastrophic collapse. Here we treat the slow-rotation, weak-magnetic field limit in which E_r_o_t<magnetic energy, and W is the gravitational binding energy of the star. We assume the system ...
This paper presents some situations, in which measurements of electromagnetic fields generated by transmission lines and substations should be performed. The range of measurements may differ, but maximum values of electric and magnetic fields and flux density must be identified in all situations. The area with electric field exceeding 1 kV/m should be identified as well. The author also presents basic requirements to be met by the measurement technique. These requirements are specified according to the national standard. Special attention should be paid to the identification of the spatial distribution of electric field and flux density generated in the vicinity of high voltage transmission lines. To verify the measurement results, it is necessary to calculate the distribution of both aforesaid field components. For environmental protection purposes, it is also proposed that the report should include measurements of ...
In the present paper we estimate the effect of sodium in the in-service inspection of non-magnetic steam generators tubes using eddy current technique and eddy current probes based on a differential double bobbin coil configuration. Experimental measurements of defects signals in steam generator tubes of fast breeder reactor are compared with simulations results of a two-dimensional axisymmetric finite element code to validate a reliable electromagnetic model of the system (eddy current coils, steam generator tube, defect) when there is no sodium on the outer steam generator tube surface. The electromagnetic code is used to evaluate the sodium band and sodium layer signals when a defect is located under steam generator support plate. Using a multi-frequency algorithm, its parameters are determined in the 'no sodium condition' (there is no sodium on the outer ...
It is well known that one of the main advantages of the high speed forming (HSF) processes is the improvement in the forming limits of the used materials.Using the Electromagnetic Forming (EMF) technology two materials have been tested with different mechanical and physical properties: the AA5754 aluminium and the AZ31B magnesium alloys.The EMF process principle can be described as follows: A significant amount of electrical energy is stored in a bank of capacitors which are suddenly discharged releasing all the stored energy. This electric discharge runs through a coil which generates an intense transient magnetic field. At the same time transient Eddy currents are induced in the electrically conductive part placed some millimetres far from the coil. Another intense magnetic field is generated due to those Eddy currents but on the opposite direction as the one generated by the ...
It is well known that one of the main advantages of the high speed forming (HSF) processes is the improvement in the forming limits of the used materials.Using the Electromagnetic Forming (EMF) technology two materials have been tested with different mechanical and physical properties: the AA5754 aluminium and the AZ31B magnesium alloys.The EMF process principle can be described as follows: A significant amount of electrical energy is stored in a bank of capacitors which are suddenly discharged releasing all the stored energy. This electric discharge runs through a coil which generates an intense transient magnetic field. At the same time transient Eddy currents are induced in the electrically conductive part placed some millimetres far from the coil. Another intense magnetic field is generated due to those Eddy currents but on the opposite direction as the one generated by the ...
A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.
Full text: It was recently-established for hexagonal barium ferrite-industrially important magnetically hard material that refinement of the crystallite dimensions into the nanoscale regime, typically #<=# 10 nm, leads after heat treatment at temperatures 800-1000 deg C to significant coercivity increase of up to 6.5 kOe (#approx#3-4 times) with saturation magnetisation values of 50-55 emu/g (#approx#95% of bulk at room temperature). High-energy mechanochemical processing has been applied to prepare nanostructural (nanocrystalline-amorphous) composites. High resolution electron microscopy studies reveal that the enhancement of the final magnetic properties was due to formation of magnetically noninteracting #approx#l,#mu#m Ba-ferrite particles with 5-10 nm amorphous surface layer - depending on annealing parameters. Similar situation was established also for ball milled strontium ferrite (SrFe_1_2O_1_9) powders where ...
Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available
Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ...
Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission should correlate with the gamma-ray emission, delayed with ...
The NRL Long Pulse Induction Linac is being employed in a Free Electron Laser (FEL) experiment. The authors present results of beam transport and focusing experiments as well as measurements of the output radiation generated by various magnetic wigglers. The electron gun of the accelerator presently has a 17-cmdiam. cold cathode which is located in a nearly zero magnetic field (B /SUB z/ less than or equal to 5 G). The gun voltage is flat to within approx. = + or - 5% for 1.5 #mu#sec with this graphite brush cathode. The beam is focused by a series of solenoidal coils as it propagates through the 4-m-long accelerator."2 A solenoidal field which can be varied from 1-10 kG confines the beam in the FEL interaction region. Previous experiments were limited by poor beam transport, focusing, and matching into the relatively large solenoidal field in the FEL region. By smoothing the axial magnetic field ...
The effect of transverse magnetic field parameter (Hartmann number, Ha) Reynolds number (Re) and Prandtl number (Pr) on the mixed convection flow past a semi-infinite vertical porous plate in a non-Darcian porous medium with variable viscosity and porosity, viscous dissipation and fluid-solid thermal conductivity ratio in the presence of plate transpiration (lateral mass flux) is investigated theoretically and numerically using Keller`s implicit finite difference scheme. It is shown that the Harmann number acts as a retarding force and increases the momentum boundary layer thickness, analogous to the flow against a positive pressure gradient, simultaneously decreasing local skin friction (shear stress). The heat transfer rate is however enhanced by the magnetic field (for positive values of the Eckert number) since the fluid is heated and temperature gradients become reduced between the fluid and the plate, with important potential applications ...
... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...
in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...
The UTST (University of Tokyo Spherical Tokamak) device was constructed for the purpose of exploring the formation of ultra-high beta ST (Spherical Tokamak) plasma using the double null plasma merging method. When two plasmas merge together to form a single plasma, magnetic field lines reconnect, and the magnetic field energy is converted to the plasma kinetic energy, increasing the plasma beta. The merging start-up has been demonstrated in the TS-3/4, START and MAST devices using coils inside the vacuum vessel and TS-3 plasma obtained 50% beta. In order to demonstrate the start-up in a more reactor relevant situation, UTST has all poloidal field coils outside the vacuum vessel. The first plasma experiment on the UTST was performed from December, 2007. In the result, the plasma obtained 10 kA by using only outer PF coils and single ST was generated at the lower area (z=-0.3 - -1.0[m]) close to a washer gun. This result ...
Horizontal vibrations of elevator cars mainly occur because a car swings as roller guides installed at corners of a car frame move on a winding guide rail at high speeds. Rider comfort in high speed elevators is worsened by these vibrations. Conventional active dampers suppressing horizontal vibrations using ac servo motors make cars heavier so driving power becomes larger, and they are not easily applied to existing elevators. An active damping control method suited to super-high-speed elevators is which can solve these problems. The method suppresses vibrations by generating only enough magnetic force needed to suppress them only when vibrations of the car franc are produced. The vibrations are detected using acceleration detectors and magnets installed on left and right sides of the car frame. A computer simulator was made to analyze phenomena of car vibrations and to verify effects of the proposed ...
Apart from conventional phase transitions driven by the thermal effects, quantum phase transitions generated by quantum fluctuations have their own mechanisms that are reflected in critical phenomena. Quantum phase transitions have an origin from spontaneous symmetry breaking commonly to thermal phase transitions. Even in this case, inherent quantum fluctuations substantially modify and yield new aspects. Quantum phase transitions have, however, another mechanism caused by topology changes, which gives completely new characters. Recently, a mechanism which connects these two has been found. Proimities from first-order transitions and phase separatins as well as from multiphase coexistence also generate characteristic and unconventional quantum criticalities. Understanding novel quantum criticalities offers a firm basis of recent active researches on fields such as magnetism, ferroelectricity and metal-insulator transitions ...
An analysis is presented for the effects of chemical reaction and thermal radiation on hydromagnetic free convection heat and mass transfer for a micropolar fluid via a porous medium bounded by a semi-infinite vertical porous plate in the presence of heat generation. The plate moves with a constant velocity in the longitudinal direction and the free stream velocity follows an exponentially small perturbation law. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micropolar fluid with a suction velocity varying with time. Analytical expressions are computed numerically. Numerical calculations are carried out the purpose of the discussion of the results which are shown on graphs and the effects of the various dimensionless parameters entering into the p...
In the present paper we prove moderate deviations for a Curie-Weiss model with external magnetic field generated by a dynamical system, as introduced by Dombry and Guillotin-Plantard. The results extend those already obtained in the case of a constant external field by Eichelsbacher and L\\"owe. The Curie-Weiss model with dynamic external field is related to the so called dynamic Z-random walks. We also prove a moderate deviation result for the dynamic Z-random walk, completing the list of limit theorems for this object.
The process of miniemulsification allows the generation of small, homogeneous, and stable droplets containing monomer or polymer precursors and magnetite which are then transferred by polymer reactions to the final polymer latexes, keeping their particular identity without serious exchange kinetics involved. It is shown that the miniemulsion process can excellently be used for the formulation of polymer-coated magnetic nanoparticles which can further be used for biomedical applications. The use of high shear, appropriate surfactants, and the addition of a hydrophobe in order to suppress the influence of Ostwald ripening are key factors for the formation of the small and stable droplets in miniemulsion and will be discussed. Two different approaches based on miniemulsion processes for the encapsulation of magnetite into polymer particles will be presented in detail.
This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)
Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high {Tc} superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high {Tc} superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is ...
The present article outlines major features of the free electron laser (FEL) and reviews research and development of FEL. Relations among the oscillation frequency, electron beam parameters and wiggler parameters, the physical mechanism of amplification and the physical process of saturation are discussed to identify the difference between FEL and other lasers. The report also outlines techniques for accelerators which are used to generate high-quality, high-energy electron beams required for FEL experiments. Techniques to achieve a short wavelength, high output and high efficiency, and applications of FEL are also discussed. FEL consists of an electron accelerator, wiggler and optical resonator. In FEL, electron beams with a relativistic energy interact resonantly with an electromagnetic field to generate coherent electromagnetic waves. Unlike conventional lasers, FEL does not surfer from restrictions on its oscillation frequency associated ...
As part of developing efforts for physical exploration technologies for oil reservoirs, this paper describes development of an active seismic while drilling (SWD). The SWD is a seismic exploration method to acquire records equivalent to VSP using seismic waves generated from a bit executing excavation, and is capable of detection and control on a real time basis during the excavation. However, the drawback is that it is subjected to a limitation in the bit. To eliminate this limitation, an artificial seismic source method was devised. In other words, this is an SWD utilizing an artificial seismic source. The contrivance is such that a shot sub containing a magnetic distortion oscillator is attached directly above a bit to generate vibration artificially, and try to utilize larger seismic energy by combining this vibration with that generated from the excavating bit. Frequency band in the seismic source ...
Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...
Magnetic fields correlated on several kiloparsec scales are seen in spiral galaxies. Their origin could be due to the winding up of a primordial cosmological field or due to amplification of a small seed field by a turbulent galactic dynamo. Both options have difficulties: There is no known battery mechanism for producing the required primordial field. Equally the turbulent dynamo may self destruct before being able to produce the large scale field, due to excess generation of small scale power. The current status of these difficulties is discussed. The resolution could depend on the nature of the saturated field produced by the small scale dynamo. We argue that the small scale fields do not fill most of the volume of the fluid and instead concentrate into intermittent ropes, with their peak value of order equipartition fields, and radii much smaller than their lengths. In this case these fields neither drain significant energy from the ...
The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to workers and the general public. The action ...
The power source facilities of JT-60 consist of poloidal magnetic coil power source, toroidal magnetic coil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual relating and retrieval by making mounted parts and spare parts into a data base and doing their unified management with a ...
The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage ...
A general relativistic model for the formation and acceleration of lowmass-loaded jets from systems containing accreting black holes is presented. The model is based on previous numerical results and theoretical studies in the Newtonian regime, but modified to include the effects of space-time curvature in the vicinity of the event horizon of a spinning black hole. It is argued that the boundary layer between the Keplerian accretion disk and the event horizon is best suited for the formation and acceleration of the accretion-powered jets in active galactic nuclei and micro-quasars. The model presented here is based on matching the solutions of three different regions: i- a weakly magnetized Keplerian accretion disk in the outer part, where the transport of angular momentum is mediated through the magentorotational instability, ii- a strongly magnetized, advection-dominated and turbulent-free boundary layer (BL) between the outer cold accretion ...
This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...
We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).
Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.
The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...
Generation of anomalous resistivity and dynamical development of collisionless reconnection in the vicinity of a magnetically neutral sheet are investigated by means of a three-dimensional particle simulation. For no external driving source, two different types of plasma instabilities are excited in the current layer. The lower hybrid drift instability (LHDI) is observed to grow in the periphery of current layer in an early period, while a drift kink instability (DKI) is triggered at the neutral sheet in a late period as a result of the nonlinear deformation of the current sheet by the LHDI. A reconnection electric field grows at the neutral sheet in accordance with the excitation of the DKI. When an external driving field exists, the convective electric field penetrates into the current layer through the particle kinetic effect and collisionless reconnection is triggered by the convective electric field earlier than the DKI is excited. It is ...
This Report includes copies of transparencies and notes from the presentations made at the Center for Accelerator Physics at Brookhaven National Laboratory Editing and changes to the authors` contributions in this Report were made only to fulfill the publication requirements. This volume includes notes and transparencies on nine presentations: ``The Energy Exchange and Efficiency Consideration in Klystrons``, ``Some Properties of Microwave RF Sources for Future Colliders + Overview of Microwave Generation Activity at the University of Maryland``, ``Field Quality Improvements in Superconducting Magnets for RHIC``, ``Hadronic B-Physics``, ``Spiking Pulses from Free Electron Lasers: Observations and Computational Models``, ``Crystalline Beams in Circular Accelerators``, ``Accumulator Ring for AGS & Recent AGS Performance``, ``RHIC Project Machine Status``, and ``Gamma-Gamma Colliders.``
A backward wave oscillator (BWO) filled with a strongly magnetized plasma supports TM and Trivel-piece-Gould (TG) modes. At large amplitudes these modes may act as wigglers for generating millimeter waves via free electron laser instability. The nonlinear coupling between the wiggler, the beam space charge mode, and the high frequency free electron laser wave is dominated by parallel motions. In the Raman regime the growth rate of instability goes as #approx##omega#_p_b"1"/"2/#gamma#_o"9"/"4, where #omega#_p_b is the beam plasma frequency and #gamma#_o is the relativistic gamma factor.
We propose an extension of the su(2,2|4) superalgebra to incorporate the F1/D1 string charges in type IIB string theory on the AdS_5 X S^5 background, or the electro-magnetic charges in the dual super Yang-Mills theory. With the charges introduced, the superalgebra inevitably undergoes a noncentral extension, as noted recently in [1]. After developing a group theoretical method of obtaining the noncentral extension, we show that the charges form a certain nonunitary representation of the original unextended superalgebra, subject to some constraints. We solve the constraints completely and show that, apart from the su(2,2|4) generators, there exist 899 complex brane charges in the extended algebra. Explicitly we present all the super-commutators among them.
An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may be employed to ...
The plastic deformation behavior of formed CICC for the superconducting Tokamac fusion device was examined and appropriate manufacturing information was provided. A relation between travel of the bending roller and spring back displacement was obtained via virtual manufacturing. The radius of CICC after forming was expressed as a function of the bend-roll travel. The maximum von Mises stress after spring back was also monitored for the SAGBO prediction. Next, the variation of the CICC cross-sectional area was examined during the first turn and during conduit bending with the largest curvature. Finally, the coil radius was measured and compared with the data generated from the virtual manufacturing. The measured data showed similar pattern as predicted one. Using the mapping function found to match with the real data, the data from the virtual manufacturing may facilitate accurate manufacturing.
The plastic deformation behavior of formed CICC for the superconducting Tokamac fusion device was examined and appropriate manufacturing information was provided. A relation between travel of the bending roller and spring back displacement was obtained via virtual manufacturing. The radius of CICC after forming was expressed as a function of the bend-roll travel. The maximum von Mises stress after spring back was also monitored for the SAGBO prediction. Next, the variation of the CICC cross-sectional area was examined during the first turn and during conduit bending with the largest curvature. Finally, the coil radius was measured and compared with the data generated from the virtual manufacturing. The measured data showed similar pattern as predicted one. Using the mapping function found to match with the real data, the data from the virtual manufacturing may facilitate accurate manufacturing.
Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.
Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.
Superconducting magnetic energy storage (SMES) is an emerging technology with features that are potentially attractive in electric utility applications. This study evaluates the potential for SMES technology in the generation, transmission, distribution, and use of electric energy; the time frame of the assessment is through the year 2030. Comparisons are made with other technology options, including both commercially available and advanced systems such as various peaking generation technologies, transmission stability improvement technologies, and power quality enhancement devices. The methodology used for this study focused on the needs of the market place, the capabilities of S and the characteristics of the competing technologies. There is widespread interest within utilities for the development of SMES technology, but there is no general consensus regarding the most attractive size. Considerable uncertainty exists ...
We proposed that a new type of the electrostatic microwiggler with a wiggler period (0.1 mm {le}1{sub w}{le}1 mm) and the wiggler field strength (E{sub w}{le} 100 kV/m) can be produced on the surface of a PZT when a high power and high frequency ultrasonic wave travels through a PZT bar. Numerical simulations in the linear and nonlinear gain regime show that a weak microwiggler (E{sub w}100 kV/m,{lambda}{sub w}{approx}100 periods), operating in magnetoresonance with a strong guide field (B{sub o}{approx} 3.6T), can generate a millimeter and submillimeter radiations with medium electronic efficiency of few percents. It is shown that the maximum output power of the compact FEL using the wiggler system generated on the surface of the piezoelectric material may be upto a few Watts with a relatively low energy and low current electron beam (Ew {approx}100 keV and I{sub b}1 mA).
This document reports on the work done by the Separations Science and Technology Programs of the Chemical Technology Division, Argonne National Laboratory, in the period April-September 1993. This effort is mainly concerned with developing the TRUEX process for removing and concentrating actinides from acidic waste streams contaminated with transuranic (TRU) elements. The objectives of TRUEX processing are to recover valuable TRU elements and to lower disposal costs for the nonTRU waste product of the process. Other projects are underway with the objective of developing (1) evaporation technology for concentrating radioactive waste and product streams such as those generated by the TRUEX process, (2) treatment schemes for liquid wastes stored or being generated at Argonne, (3) a process based on sorbing modified TRUEX solvent on magnetic beads to be used for separation of contaminants from radioactive and hazardous waste ...
Low-temperature #gamma# radiolysis and photolysis of crystalline 2,4,6-triazido-3,5-dichloropyridine (TAP) were studied by means of the ESR technique. It was found that the long-term irradiation of TAP at 77 K leads to the appearance of characteristic signals of quintet 2,6-dinitreno-4-azido-3,5-dichloropyridine and 2,4-dinitreno-6-azido-3,5-dichloropyridine; the radiation-chemical yield was 0.035 and 0.012 molecule/100 eV, respectively. The photolysis of crystalline 2,4,6-triazido-3,5-dichloropyridine proceeded less effectively, producing only quintet 2,6 dinitrene with a quantum yield of #approx#4.5 x 10"-"4. The study showed that the generation of high-spin nitrenes via radiolysis of crystalline azides is much superior to the photochemical technique in efficiency and may be of practical importance for the preparation of magnetically active organic materials
This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a modulation, the FEL can present a periodic or chaotic regime. The analysis of these ...
We study the time evolution of a brane construction that is holographically dual to a strongly coupled gauge theory that dynamically breaks a global symmetry through the generation of an effective composite Higgs vev. The D3/D7 system with a background magnetic field or non-trivial gauge coupling (dilaton) profile displays the symmetry breaking. We study motion of the D7 brane in the background of the D3 branes. For small field inflation in the field theory the effective Higgs vev rolls from zero to the true vacuum value. We study what phenomenological dilaton profile generates the slow rolling needed, hence learning how the strongly coupled gauge theory's coupling must run. We note that evolution of our configuration in the holographic direction, representing the phyiscs of the strong interactions, can provide additional slowing of the roll time. Inflation seems to be favoured if the coupling changes by only a small amount ...
Using the ammonia (NH3) plasma generated by a helical antenna surrounded by two magnetic coils, the transition of the discharge mode from low-density plasma to high-density one was observed. At the transition, the emission intensities from the H atoms and NH radicals especially increased in the optical emission spectroscopy, while the intensities of the other emission lines also increased abruptly. The nitridation of gallium arsenide (GaAs) surface was performed using the high-density NH3 plasma, and the properties of the nitrided surface layer were compared with those nitrided by high-density N2 plasma using the same apparatus. From the spectroscopic ellipsometry measurements, the thickness of the nitrided layer was estimated to be 16-18 nm, while that by N2 was 3-4 nm. From the Ga 3d spectra, the contamination with oxygen in the nitridation layer by NH3 plasma was less than that by N2 plasma.
BC Hydro recently conducted a demonstration test of a bearing condition monitor. The test, at the 529-MW Kootenay Canal project, proved the ability of the monitor to detect machine condition faults. The capability to detect changing conditions during normal operation of hydroelectric machines gives hydro plant owners the opportunity to anticipate needed maintenance and ultimately to reduce the number of equipment failures. BC Hydro intends to install bearing condition monitors, as well as windings monitors, brushgear monitors, environmental monitors, and other selected systems in as many as 46 of its hydro generators. BC Hydro analyzed forced outages between 1985 and 1989 in its hydro system to identify which parts of a generating unit resulted in the highest number of hours of outage. From there, the utility has formulated a concept for a machine condition monitoring system. To keep the system cost effective, it will be developed in modules. ...
Single crystals of semi-organic L-histidine hydrobromide have been grown by slow evaporation technique from a mixture of L-histidine and hydrobromic acid in aqueous solution at ambient temperature. From high-resolution X-ray diffraction analysis, the crystalline perfection of the grown crystal has been studied. Single crystal X-ray diffraction analyses, Nuclear Magnetic Resonance spectral analysis, Thermo-Gravimetry (TG), Differential Thermal Analysis (DTA) and hardness test have been employed to characterize the as-grown crystals. The UV cutoff wavelength of the grown crystal is below 300 nm and has a wide transparency window, which is suitable for second harmonic generation of laser in the blue region. Nonlinear optical characteristics have been studied using Q switched Nd:YAG laser (#lambda#=1064 nm). The second harmonic generation conversion efficiency of the grown crystals confirms their suitability for frequency ...
The generation of fusion power from the Fast-Liner Reactor (FLR) concept envisages the implosion of a thin (3-mm) metallic cylinder (0.2-m radius by 0.2-m length) onto a preinjected plasma. This plasma would be heated to thermonuclear temperatures by adiabatic compression, pressure confinement would be provided by the liner inertia, and thermal insulation of the wall-confined plasma would be established by an embedded azimuthal magnetic field. A 2- to 3-mu s burn would follow the approx. 10"4 m/s radial implosion and would result in a thermonuclear yield equal to 10 to 15 times the energy initially invested into the liner kinetic energy. For implosions occurring once every 10 s a gross thermal power of 430 MWt would be generated. The results of a comprehensive systems study of both physics and technology (economics) optima are presented. Despite unresolved problems associated with both the physics and technology of the FLR, ...
This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.
In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.
Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals ...
The authors report on observations of plasma wave turbulence generated during electron beam injections, spacecraft potential variations, and neutral gas emissions of the CHARGE 2 sounding rocket experiment. The payload was flown in a mother/daughter configuration, with the two sub-payloads electrically connected by an insulated, conducting tether. While tethered, the two platforms were separated, drifting apart in a direction perpendicular to both the magnetic field and to the spacecraft velocity, reaching a maximum distance of 426 m at the end of the flight. The mother carried a high-voltage (HV) system (0-460 V), biasing the mother negative relative to the daughter. The operation of the HV bias system simulated the motional emf induced in larger orbiting space structures like the Tethered Satellite System 1 (TSS 1) space shuttle mission scheduled for the spring of 1992. In addition, the mother carried an electron beam accelerator (1 keV, 0-46 ...
For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a system of 192 beam lines, each focused by ...
Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)
To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)
Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...
Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We ...
A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)
A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.
Due to the cyclical human life, utility loads appear to be cyclical too. During daytime when most factories are in operation, the electricity demand is very high. On the contrary, when most people are sleeping from midnight to daybreak, the electric load is very low, usually only half of the peak load amount. To meet this large gap between peak load and light load, utilities must idle many generation plants during light load period while operating all generation plants during peak load period no matter how expensive they are. This low utilization factor of generation plants and uneconomical operation have sparked utilities to invest in energy storage devices such as pumped storage plants, compressed air energy storage plants, battery energy storage systems (BES) and superconducting magnetic energy storage systems (SMES) etc. Among these, pumped storage is already commercialized and is the most widely ...
Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.
The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...
The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.
Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)
A multicusp magnetic field plasma surface ion source, normally used for H/sup -/ ion beam formation, has been utilized for the generation of high intensity, pulsed, heavy negative ion beams suitable for a variety of uses including tandem electrostatic accelerator/synchrotron injection applications. Sputter probe voltage limited total ion currents of 5.5, 8.2, 5.1 and 4.5 mA (peak intensity) have been produced from Au, Cu, Ni and CuO sputter probes, respectively. The mass distributions of these ion beams are found to be dominated by Au/sup -/, Cu/sup -/, Ni/sup -/ and O/sup -/ atomic species, respectively. The source offers the interesting prospect of providing cw negative ion beams at mA intensity levels of the commonly used semiconducting material dopants (e.g. B/sup -/, P/sup -/, As/sup -/ and Sb/sup -/) as well as O/sup -/ for isolation barrier formation. Illustrative examples of intensity versus time and the mass distribution of ion beams ...
Recent preliminary results from the PAMELA satellite indicate the presence of a large flux of positrons (relative to electrons) in the cosmic ray spectrum between approximately 10 and 50 GeV. As annihilating dark matter particles in many models are predicted to contribute to the cosmic ray positron spectrum in this energy range, a great deal of interest has resulted from this observation. Here, we consider pulsars (rapidly spinning, magnetized neutron stars) as an alternative source of this signal. After calculating the contribution to the cosmic ray positron and electron spectra from pulsars, we find that the spectrum observed by PAMELA could plausibly originate from such sources. In particular, a significant contribution is expected from the sum of all mature pulsars throughout the Milky Way, as well as from the most nearby mature pulsars (such as Geminga and B0656+14). The signal from nearby pulsars is expected to generate a small but ...
Burnable poisons are used in nuclear reactors to produce a more level distribution of power in the reactor core and to reduce to necessity for a large control system. An ideal burnable poison would burn at the same rate as the fuel. In this study, separation of neutron-absorbing isotopes was investigated in order to eliminate isotopes that remain as absorbers at the end of fuel life, thus reducing useful fuel life. The isotopes Gd-157, Dy-164, and Er-167 were found to have desirable properties. These isotopes were separated from naturally occurring elements by means of plasma separation to evaluate feasibility and cost. It was found that pure Gd-157 could save approximately $6 million at the end of four years. However, the cost of separation, using the existing facility, made separation cost- ineffective. Using a magnet with three times the field strength is expected to reduce the cost by a factor of ten, making isotopically separated burnable poisons a favorable ...
The COBE data on cosmic background radiation (CBR) isotropy and spectrum are generally considered to be explicable only in the context of the Big Bang theory and to be confirmation of that theory. However, this data can also be explained by an alternative, non-Big Bang model which hypothesizes an intergalactic radio-absorbing and scattering medium. Dense, force-free magnetic filaments generated by quasars, active galactic nuclei and Herbig-Haro objects can remain stable in the intergalactic medium for many Gy. They will be opaque to radiation with wavelengths longer than 100--400 microns, and essentially transparent to shorter wavelengths. They are thus capable of thermalizing and isotropizing the cosmic background radiation, and of accounting for the observed decrease of radio luminosity of galaxies within increasing distance from earth. A simple, inhomogeneous model of such an absorbing medium can reproduce both the isotropy and spectrum of ...
The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it ...
A multicusp magnetic field plasma surface ion source, normally used for H/sup /minus//ion beam formation, has been modified for the generation of high-intensity, pulsed, heavy negative ion beams suitable for a variety of uses. To date, the source has been utilized to produce mA intensity pulsed beams of more than 24 species. A brief description of the source, and basic pulsed-mode operational data, (e.g., intensity versus cesium oven temperature, sputter probe voltage, and discharge pressure), are given. In addition, illustrative examples of intensity versus time and the mass distributions of ion beams extracted from a number of samples along with emittance data, are also presented. Preliminary results obtained during dc operation of the source under low discharge power conditions suggest that sources of this type may also be used to produce high-intensity (mA) dc beams. The results of these investigations are given, as well, and the technical ...
The tidal motion of the ocean water through the ambient magnetic field, generates secondary electric field. This motionally induced electric field can be detected in the sea or inland and has a potential for electrical soundings of the Earth. A first goal of the paper is to gain an understanding of the global distribution of the electric signal due to tidal ocean flow. We simulate the electric signals for two tidal constituents - lunar semidiurnal (M2) and diurnal (O1) tides. We assume a realistic Earth's conductivity model with a surface thin shell and 1-D mantle underneath. Simulations demonstrate that in some coastal regions the amplitudes of the electric field can reach 100 mV/km and 10 mV/km for M2 and O1 tides respectively. The changes of lithosphere resistance produce detectable changes in the tidal electric signals. We show that our predictions are in a good agreement with observations.
Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...
OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available
Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.
The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be ...
The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).
Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...
Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...
It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)
... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...
Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.
Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries
The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...
A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI ...
With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...
... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...
has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magnetic coil is placed over a thin aluminum ...
From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...
For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...
magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...
Vacuum arc with cathode spots on the cold electrode is widely used as a plasma generator in a such kind of devices like metal ion sources, plasma cathode electron guns, thing films deposition facilities and others. Most vacuum arc devices utilize a high voltage discharge across an insulator surface to provide a trigger plasma which in turn initiates the main arc discharge. Operation of vacuum arc in a repetitively pulsed mode required a stable triggering system for the long time. But with a discharge across the insulators the number of stable pulses is limited by 100,000 or little bit more. The better method for vacuum arc ignition is low pressure discharge. As shown in this paper it is possible to increase the lifetime of the ignition system in 10 times at least, but negative characteristic of this system is a relatively high pressure (about 0.1 mtorr). In some kinds of vacuum arc applications it is impermissible because it leads to the ...
A top-level costing model is developed and used to project the cost of electricity (COE) (in mills per kilo watt-hour) expected from conceptual fusion power plants. Application is restricted to magnetic fusion energy (MFE) concepts. These costs are estimated parametrically in terms of the mass of the fusion-power-core (FPC) heater, the power required to sustain a reacting deuterium-tritium plasma, the heat transport/transfer system that delivers the fusion power to the balance of plant (BOP), and the BOP needed to convert the fusion heat to electrical power. Although the highly integrated (simplified) cost-estimating relationships (CERs) used to express COE in terms of FPC mass power density (MPD) [in kilowatt(electric) per tonne] and the engineering gain Q{sub E} (inverse of fraction of gross electric power recirculated to the fusion power plant) apply primarily to MFE approaches to fusion power, the costing gauge thus results is generally independent of ...
The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the ...
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting ...
180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector ...
Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar ...
Three different magnetic regimes; aerial, surface and buried; each with three different forces, have been used to investigate their effects on the water contents and photosynthetic pigments of sweet basil plants (Ocimum basilicum L.). Two groups of sweet basil seeds, Ocimum basilicum L. have been cultivated, one under normal conditions and the second has been subdivided into three portion (aerial, surface and buried) to examine the effect of different magnetic forces coming from the three directions on the resulted plants. At all directions of magnets, water contents have been significantly affected by the magnetic forces. Chlorophyll A and carotene contents have been affected, as well, according to the three magnetic forces coming from soil surface regime only. Chlorophyll B did not significantly affected by differences magnetic forces in the three regimes, but ...
The effects of a moderate-intensity static magnetic field (SMF) on osteoporosis of the lumbar vertebrae were studied in ovariectomized rats. A small disc magnet (maximum magnetic flux density 180 mT)...Full Text Available
Using the full potential linearized augmented plane wave (FLAPW) method, thickness dependent magnetic anisotropy of ultrathin FeCo alloy films in the range of 1 monolayer (ML) to 5 ML coverage on Pd(0 0 1) surface has been explored. We have found that the FeCo alloy films have close to half metallic state and well-known surface enhancement in thin film magnetism is observed in Fe atom, whereas the Co has rather stable magnetic moment. However, the largest magnetic moment in Fe and Co is found at 1 ML thickness. Interestingly, it has been observed that the interface magnetic moments of Fe and Co are almost the same as those of surface elements. The similar trend exists in orbital magnetic moment. This indicates that the strong hybridization between interface FeCo alloy and Pd gives rise to the large magnetic moment. Theoretically calculated ...
In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)
Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.
The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered
The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.
Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.
Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the photocathode RF gun injection system. ...
A home-made 3.1 kWh wind turbine that is promising to be the hottest new wind product to appear for home/farm users in some time, is described. The turbine is installed near a farm house in the high wind area of Mount Forest, Ontario. The turbine is hooked up to a four kilowatt Trace inverter charger which is coupled through a DC disconnect and C-60 charge controller to two sets of solar panels (seven panels of 120 W each by Solarex SX 120, and five panels by Sharp, each providing 1600 watt of solar power). The wind turbine and the solar panels, assisted by two 65-year old refurbished wind turbines, one bank of Gel Cell batteries, and an Onan 5 kW gas generator supply the electrical requirements of a seven member family in a 3400 square foot house. The new turbine is mounted on an 80-foot tower, has three eight foot Kevlar blades that produce a 17 foot overall sweep. The turbine weighs 615 lbs., produces 3.1 kW of pure power at just 310 rpms at a low start up wind ...
The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...
The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...
This paper reports that only a few years ago superconducting magnetic separation was viewed as the next major market for superconducting magnets. The first commercial units had been installed, worked flawlessly, and demonstrated real economic viability. The potential market was seen as quite large, and many people believed that superconducting magnetic separation would soon show the same rapid growth that MRI had demonstrated after its initial success. These hopes even prompted IGC, one of the top MRI magnet builders, to form a separate division devoted to magnetic separation. Despite the existence of Magstream, IGC has not been overly active in the market. As a technology that has applications from the clay on the Earth to the soil on the moon, superconducting magnetic separation has yet to become widely used.
The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal force balance in the stellarator-like ...
We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and ...
This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.
We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# function shows that ...
We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.
We discuss how magnetic phenomena affect superconductivity in simple metals, transition metals and alloys thereof, and dilute Rare-Earth alloys. It is shown both qualitatively and quantitatively that superconductors are sensitive probes for studying itinerant spin excitations, local spin excitations associated with nearly magnetic impurities, the effect of the atomic environment on the stability of local magnetic moments, and the nature of the spin order in Rare-Earth alloys. Also, we discuss how magnetic impurities can be used to study the electronic configuration which is responsible for superconductivity in Laves-phase crystals like A-15 compounds and ..beta..-W crystals, for example.
The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.
It has been carried out the magnetic properties determination for high iron oxide content glasses series obtained from a geothite red mud waste from the zinc hydrometallurgy and dolomite and glass cullet as main raw materials. It has been determined the magnetic susceptibility and magnetization values for the glasses here investigated. The results suggest that the magnetic behaviour are depending on the glass chemical composition, so that glasses can be differently classified like ferrimagnetic, ferromagnetic, superparamagnetic and paramagnetic. (Author) 6 refs.
Magnetic fluctuations present in the paramagnetic Mn{sub 0.81}Ni{sub 0.19} system have been investigated by measuring inelastic magnetic neutron scattering from a single crystal at temperatures of 450, 585 and 700 K. Antiferromagnetic correlations are observed to be present at all the temperatures studied. The spectral width of the magnetic scattering has been observed to increase with temperature, while the spatial range of the magnetic correlations is seen to decrease as the temperature is raised. The wave-vector-dependent susceptibility is found to follow a Curie-Weiss law near the (1 0 0) position, in agreement with theoretical predictions.
It is suggested that the magnetic Ap stars can be rotationally decelerated to long periods by the braking action of the associated magnetic field on time scales of order 10"7--10"1"0 years depending on whether the star's dipole field is aligned perpendicular or parallel to the rotation axis. Rotation includes a toroidal magnetic field in the plasma surrounding a star, and the accompanying magnetic stresses produce a net torque acting to despin the star. These results indicate that it is not necessary to postulate mass loss or mass accretion for this purely hydromagnetic braking effect.
The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.
As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the ...
Anisotropic Nd{endash}Fe{endash}B magnet powders can be produced by the hydrogenationdecomposition-desorption-recombination (HDDR) process from Nd{endash}Fe@ xnB{endash}Co{endash}M ({ital M}=Ga, Zr, Nb, Hf, and Ta) alloys. The present status of those HDDR powders and the bonded magnets made from them are reviewed with regards to the powder particle size dependence of their magnetic properties, their magnetic thermal stability, and their magnetization behavior. The results of a mechanistic study on the recombination step are also presented. The magnetic properties of the anisotropic HDDR powder depend relatively little on the powder particle size. Bonded magnets with a density of {approximately}6.20 g/cm{sup 3} and a BH{sub max} of 18.5{endash}20.5 MGOe can be produced from anisotropic HDDR powders with particle sizes of below 300 {mu}m diam. ...
Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY ...
The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was ...
Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus simulating the human ...
With "1"5"1Eu-Moessbauer spectroscopy and other methods the complex magnetic properties of Eu_2PdSi_3, arising from the two crystallographically different lattice sites of the Eu"2"+ ions, have been already studied. Here we study the impact of magnetic dilution of the magnetic Eu"2"+ sites by non-magnetic Y"3"+ ions. A previous specific heat study has found reduced magnetic ordering temperatures with strong indication of disorder effects like in magnetic spin glasses. Here we provide from "1"5"1Eu-Moessbauer spectroscopy detailed information of the impact of Y"3"+ substitution on the magnetic properties of the two lattice sites, well distinguishable in the "1"5"1Eu-spectra. Since the substitution of the larger Eu"2"+ ions by the smaller Y"3"+ ions is connected with a lattice contraction, we also applied high pressure to the Eu_2PdSi_3 sample ...
The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.
The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.
The Recycler ring magnet will be made of Strontium ferrite permanent magnets. A strontium ferrite permanent magnet without compensation has a temperature coefficient of -0.2 % in dB/dT. To compensate this effect, we are utilizing 30 % Ni 70 % Fe alloy, a temperature compensation ferromagnetic material with a low Curie point. To search for optimum commercially available material and optimum condition, we made a couple of simple model magnets, and tested with several different compensating material. The test results are reported and its optimal conditions are shown. Several different configurations were tested including a possible 2 kG magnet configuration.
We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large heating power.
The magnetic properties of polycrystalline and single crystalline rare earth transition metal silicides Gd_xLa_1_-_xMSi (M =Fe, Co) were investigated. Magnetic measurements have been made in static magnetic fields up to 13 kOe and in pulsed magnetic fields up to 250 kOe in the temperature range from 4.2 to 350 K. The magnetic susceptibility in the paramagnetic state of all the investigated compounds obeys the Curie-Weiss law except for LaFeSi and LaCoSi. Increase of the La content in Gd_xLa_1_-_xFeSi compounds leads to a decrease of the Curie and Neel temperatures, which can be explained by a decrease of positive exchange interactions. (orig.).
Sensitive and quick-response nonlinear inductance characteristics are found for high Tc superconducting (YBa/sub 2/Cu/sub 3/O/sub 7-chi/) disk cores at 77K in which soft magnetic BH hysteresis loops are observed. Various quick response magnetic devices such as modulators, amplifiers and sensors are built using these cores. The magnetizing frequency can be set to more than 20 MHz, which is difficult for conventional ferromagnetic bulk materials such as Permalloy amorphous alloys and ferrite. New quick-response fluxgate type magnetic-field sensors are made using ac and dc voltage sources. The former is used for second-harmonic type sensors, while the latter is for voltage-output multivibrator type sensors. Stable and quick-response sensor characteristics were obtained for two-core type multivibrators.
The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.
We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...
The Large Hadron Collider (LHC) will be equipped with several thousands of superconducting corrector magnets. Among the largest ones are the superconducting trim quadrupoles (MQTL). These twin-aperture magnets with a total mass of up to 1700 kg have a nominal gradient of 129 T/m at 1.9 K and a magnetic length of 1.3 m. Sixty MQTL are required for the LHC, 36 operating at 1.9 K in and 24 operating at 4.5 K. The paper describes the design features, and reports the measured quench performance and magnetic field quality of the production magnets. The MQTL magnet production is shared between CERN and industry. This sharing is simplified due to the modular construction, common to all twin-aperture correctors.
Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe_7_8Si_9B_1_3 were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe_7_8Si_9B_1_3. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase (#alpha#-Fe(Si), the grain size, 2-10 nm) is 3-7%. The temperature rise ...
This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.
The investigated hybrid nanocomposite consists of a porous silicon template with electrochemically embedded Ni or Co nanostructures and offers magnetic characteristics which can be tailored by the electrochemical process parameters during fabrication. A twofold magnetic behaviour can be observed, a first one due to the spinmagnetism at magnetic fields below the saturation magnetization of the deposited metals and a second non-saturating term at higher fields (>1 T up to 7 T) above the saturation magnetization. In case of Ni deposited within the pores this non-saturating term shows a paramagnetic characteristic and follows exactly the Curie-Weiss law, whereas for Co/porous silicon samples the temperature dependent magnetization shows some deviations from the Curie Weiss law. In this high field region a difference in the temperature dependence between Ni ...
The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system besides the ...
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available
The magnetic susceptibility and the density of human oxy-(HbO2) and carbonmonoxyhemoglobin (HbCO) solutions of various concentrations have been measured at room temperature, with pure water...Full Text Available
OBJECTIVES: This article uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies of residential magnetic field...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
The magnetic properties of as-grown Ga1-xMnxAs have been investigated by the systematic temperature and magnetic field dependent soft x-ray magnetic circular dichroism (XMCD) measurements in the Mn L2,3 absorption edge region. The XMCD intensity at high temperatures obeys the Curie-Weiss law, but residual spin magnetic moment appears already around 100 K, significantly above Curie temperature (Tc), suggesting that short-range ferromagnetic correlations are developed significantly above Tc. The high-field magnetic susceptibility becomes T-independent below TC, indicating that the AF interaction between the substitutional Mn (Mnsub and interstitial Mn (Mnint) ions, which becomes strong as the Mn concentration x increases, exists and that the amount of the Mnint affects Tc. The present experimental findings should give valuable insight into the inhomogeneous ...
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
An in-plane uniaxial magnetic anisotropy has been observed in thin Co films normally deposited onto obliquely sputtered Ta and Pt underlayers. Associated with this anisotropy is an augmented easy axis coercivity. The in-plane easy axis is, in most cases, perpendicular to the incident deposition plane. Microstructural results indicate that grains are well connected along the magnetic easy axis but are separated by long continuous voids along the hard axis, which is ascribed to a geometric shadowing effect due to the oblique incidence deposition of the underlayer. Hence, the magnetic anisotropy mimics the film growth anisotropy. It is therefore believed that the observed magnetic properties are due to magnetostatic shape anisotropy effects. In-plane coercivity and anisotropy field are shown to increase with underlayer deposition angle, underlayer thickness and magnetic layer ...
A considerable amount of chemical knowledge of marine sediments has been acquired in recent years but has not yet been utilized by paleomagnetists. On the other hand, geochemists are often unaware of the usefulness of numerous magnetic techniques. In this review we try to bridge this gap, and in particular, we outline many of the chemical and magnetic principles that should allow paleomagnetists to better identify and undertand chemical changes that affect the magnetic properties of marine sediments. The chemical principles include those for distinguishing the four major sources of sediments (continental, biological, authigenic/hydrogenous, volcanic/hydrothermal) from one another by determining elemental abundance distributions, as well as for investigating the stabilities of mineral phases relative to changes in pE and pH. The magnetic principles include the effects of authigenesis and diagenesis on ...
ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available
Major breakthroughs have recently been reported that can help overcome two inherent drawbacks of NMR: the lack of sensitivity and the limited memory of longitudinal magnetization. Dynamic nuclear polarization...Full Text Available
Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available
OBJECTIVES: To appraise epidemiological evidence of the purported association between residential exposure to power frequency magnetic fields and adult cancers. METHODS: Literature review and epidemiological...Full Text Available
Epidemiologic research concerning electric and magnetic fields in relation to cancer has focused on the potential etiologic roles of residential exposure on childhood cancer and occupational exposure...Full Text Available
Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available
The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a flexibility of the magnetic field configuration is realized. For the case that the rotational transform ...
The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load ...
A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available
OBJECTIVES--This case cohort study examines whether there is an association between exposure to electric and magnetic fields and suicide in a population of 21,744 male electrical utility workers from...Full Text Available
Name U.S. Geological Survey A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal Field, Nevada: A Web Site for Distribution of Data by U. S. Geological Survey &...
A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.
... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...
The read/write characteristics for perpendicular magnetic recording media of focused-ion-beam (FIB)-etched recording heads were investigated. It was found that the trailing edge of an FIB-etched head produces a higher gradient in the magnetic field perpendicular to the medium than a head which has not been etched. The signal-to-noise ratio of the medium increased with the FIB-etched write gap. A high-Bs and thin pole increased the magnetic field's gradient in the perpendicular direction, resulting in excellent read/write characteristics.
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.
The paramagnetic susceptibility of single crystals of dysprosium-yttirum alloys is measured in the basal plane and along the hexagonal axis. It is shown that the susceptibility of the alloys obeys the Curie-Weiss law, the effective magnetic moments allong the different directions being the same and the paramagnetic Curie temperatures being different. The difference between the paramagnetic Curie temperatures in the basal plane and along the hexagonal axis is independent of the dysprosium concentration in the alloy. As a comparison with the theoretical models of magnetic anisotropy shows, this is an indication that the magnetic anisotropy of dysprosium - yttrium alloys is of a single-ion nature.
A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.
This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.
The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).
The a.c. susceptibility and high field magnetization of TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} compounds were investigated up to 140 kOe. The (T, x) magnetic phase diagrams were determined. For both systems, an increase in the Pd content causes a decrease in the Neel temperature and changes the magnetization curves. (orig.)
The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.
The effect of elastic and plastic strains on the magnetic properties of ferrite-pearlite steels has been studied. It has been shown that the sensitivity to elastic-tensile and bending strains is four to five times greater for remnant magnetization than for coercive force. In order to determine the degree of cold plastic deformation of high-carbon steels, a two-parametric testing technique based on the use of remnant magnetization and coercive force was suggested. An MMT-2 device was recommended for measurement of the required parameters.
The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).
An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.
The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.
The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.
... fields, materials can be subjected to energy densities exceeding those realized in high explosives, a fact which forms the basis for magnetic forming ...
The results of the investigations show that magnetic treatment is a quite practical and effective method of intensifying certain technological processes in the coking industry. Magnetic treatment was utilized for improving the production of ammonium sulfate, refining of the naphthalene fraction, removal of sludge from wash oil in the benzol division, and the treatment of tar before fractionation. 2 references, 3 tables.
The concept of the minimum propagating zone (MPZ) is used to examine the causes of quenches in ISABELLE cosine theta superconducting dipole magnets. The size of disturbances large enough to exceed the MPZ and initiate quenches is estimated and compared with the size of disturbances which may be produced in the magnets. A suggestion for reducing the size of these disturbances through individual support of the coil block is outlined.
The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.
High-spin states in {sup 202}Pb and {sup 203}Pb have been investigated by in-beam {gamma}-ray spectroscopy following the reaction {sup 198}Pt({sup 9}Be,xn). A search for magnetic rotational bands in these isotopes confirmed one of the two bands previously assigned to {sup 202}Pb and revealed a new band in this isotope. No evidence for magnetic rotation has been found in {sup 203}Pb. (orig.)
Plasma confinement by permanent magnets has been studied. An analytic formula for the field of a single bar magnet has been obtained. Generalization to various configurations of multidipole fields has also been found. Any two-dimensional field may now be completely described by a simple function of complex variables in closed form. Vector potential has also been obtained by integrating over a prescribed Riemann surface. The confinement of plasma by multidipole fields then becomes obvious through conservation principles.
Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.
An alternative and graphical representation of the magnetic moment and the effective paramagnetic moment for polycrystalline Ce compounds with tetragonal site symmetry is described. The reduced moments can be calculated by means of standard perturbation theory. The calculated values deduced from the ground states of CeCu_2Si_2, CeRu_2Si_2, and CePd_2Si_2 polycrystals are compared with experimental magnetic moments.
Measurement of the magnetic susceptibility of powder samples of heavy rare-earth (Tb, Dy, Ho, Er, Tm and Yb) tungstates have been reported in the temperature range 300 to 900 K. Curie-Weiss law behaviour has been observed for all samples. The Curie constant, paramagnetic Curie temperature and magneton number for the magnetic ions have also been evaluated for each material. (author).
Results of experimental researches of impurity level crystals Fe1-xCoxSi are presented in this article. Magnetic properties in a temperature range up to T {<=} 1000 K are analyzed. It was established that with Co impurities increasing origin of magnetic ordering exists at low temperatures. At high temperatures a high temperature maximum of susceptibility of nominally pure iron monosilicide crystal is observed.
This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.
We report on solid solution CePd_2_-_xMn_xSi_2 which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.)).
We report on solid solution CePd[sub 2-x]Mn[sub x]Si[sub 2] which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.))
Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)
The gauge-invariant correlation function for the Yang-Mills field strengths is shown to admit a symmetric decomposition into electric and magnetic components. The spectral weights are seen to obey a sum rule of the superconvergence type, owing to asymptotic freedom. The close relation between the dielectric function, electric-magnetic duality, and the algebra of generalized Chern-Simons charges is illustrated for the linearized Yang-Mills-Higgs system.
The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).
Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...
Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...
In this letter we report a clear and unambiguous observation of the out-of-plane quadrupole magnetic field suggested by numerical simulations in the reconnecting current sheet in the Magnetic Reconnection Experiment (MRX). Measurements show that the Hall effect is large in collisionless regime and becomes small as the collisionality increases, indicating that the Hall effect plays an important role in collisionless reconnection.
Annealing of magnetostrictive Metglas foils, subsequently incorporated into laminated Metglas/Pb(Zr, Ti)O3 magnetoelectric (ME) composites, is shown to result in improved magnetic properties, as well as ME coefficients. Annealing of the foils at 350 ?C resulted in partial crystallization, without oxidation or magnetic cluster formation that would reduce the magnetization. Laminate composites made with these annealed Metglas foils had improved ME coefficients.
It is shown that recuperator in which the thermal energy of particles is transformed into electric oue under drift in crossed fields is naturally coupled with dragontype magnetic confinement system, so the recuperation process can be initiated in the dragon magnetic field. A number of questions occuring under analysis of recuperator-dragon system is considered, including the dynamics of particle transfer to the recuperator, the share of particles entering the recuperator, the effect of rotational transform and the recuperation efficiency.
Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)
The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.
Here, we consider a recent paper concerned with magnetic braking by induced currents (Ireson and Twidle 2008 Eur. J. Phys. 29 745-51). Our objective is to elucidate why measurement of speed in which a magnet is dropped through a non-ferromagnetic conductive tube depends on its geometry in a non-monotonic way, which was not clearly explained by the authors. (letters and comments)
We present a formulation of ab initio electronic structure calculations in a finite magnetic field, which retains the simplicity and efficiency of techniques widely used in first principles molecular dynamics simulations, based on plane-wave basis sets and Fourier transforms. In addition we discuss results obtained with this method for the energy spectrum of interacting electrons in quantum wells, and for the electronic properties of dense fluid deuterium in a uniform magnetic field.
Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and vapour pressure of ...
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from ...
Coilguns have demonstrated their capability to launch projectiles to 1 km/s, and there is interest in their application for long-range precision strike weapons. However, the incorporation of cooling systems for repetitive operation will impact the mechanical design and response of the future coils. To assess the impact of such changes, an evaluation of the ruggedness and reliability of the existing 50 mm bore coil designed in 1993 was made by repeatedly testing at stress levels associated with operation in a coilgun. A two-coil testbed has been built with a static projectile where each coil is energized by its own capacitor bank. Simulation models of the applied forces generated in this testbed have been created with the SLINGSHOT circuit code to obtain loads equivalent to the worst-case anticipated in a 50 mm coilgun that could launch a 236 g projectile to 2 km/s. Bench measurements of the seven remaining coils built in 1993 have been used to evaluate which coils ...
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total absorbed dose ...
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup 60}Co source to a total ...
Gyrokinetic particle simulation of edge pedestal formation and plasma rotation dynamics will be presented, and compared with experimental observations. Realistic tokamak edge geometry is used which include separatrix/X-point and material wall from EFIT g-eqdsk data. In order to handle adequately the spatially inhomogeneous electric potential in the scrape-off region, the full-f electron technique is used, in addition to the full-f ions. Monte Carlo neutral particles with wall recycling coefficient will be included self-consistently with the plasma kinetics. Ion-ion Coulomb collisions will be particle, momentum and energy conserving. Energy source for the pedestal and scrape-off plasmas is the heat flow from the core plasma, and the particle source is the ionization of the neutral atoms which are either wall recycled and/or gas puffed. The simulation will be self-consistent with the first principles nonlinear neoclassical and (electrostatic so far) turbulence interactions. Plasma ions ...
An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} ...
In 2009 the European Space Agency satellite mission GOCE (Gravity Field and Steady-State Ocean Circulation Explorer) was launched. Its objectives are the precise and detailed determination of the Earth's gravity field and geoid. Its core instrument, a three axis gravitational gradiometer, measures the gravity gradient components V xx , V yy , V zz and V xz (second-order derivatives of the gravity potential V) with high precision and V xy , V yz with low precision, all in the instrument reference frame. The long wavelength gravity field is recovered from the orbit, measured by GPS (Global Positioning System). Characteristic elements of the mission are precise star tracking, a Sun-synchronous and very low (260 km) orbit, angular control by magnetic torquing and an extremely stiff and thermally stable instrument environment. GOCE is complementary to GRACE (Gravity Recovery and Climate Experiment), another satellite gravity mission, launched in 2002. While ...
Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the analysis of CH{sub 2}, ...
Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented by heating in the vicinity of the q = 1 ...
Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall`s resistivity requirement ({sigma}*t = 2E5 {Omega}{sup {minus}1}). For a 4.2 K beam tube the Cu thickness is 100 {mu}m (RRR=30,6.7 T, {sigma}=2E9{Omega}{sup {minus}1}m{sup {minus}1}). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam tube subjected to eddy current load in a quenching dipole requires an optimum diameter design to provide ...
Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall's resistivity requirement ([sigma]*t = 2E5 [Omega][sup [minus]1]). For a 4.2 K beam tube the Cu thickness is 100 [mu]m (RRR=30,6.7 T, [sigma]=2E9[Omega][sup [minus]1]m[sup [minus]1]). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam tube subjected to eddy current load in a quenching dipole requires an optimum diameter design to ...
Nanosatellite space launches could significantly benefit from an electrically powered launch complex, based on an electromagnetic coil launcher. This paper presents results of studies to estimate the required launcher parameters and some fixed facility issues. This study is based on electromagnetic launch, or electromagnetic gun technology, which is constrained to a coaxial geometry to take advantage of the efficiency of closely-coupled coils. A baseline configuration for analysis considers a payload mass of 10 kg, launch velocity of 6 km/s, a second stage solid booster for orbital insertion, and a payload fraction of about 0.1. The launch facility is envisioned as an inclined track, 1-2 km in length, mounted on a hillside at 25 degrees aimed in the orbital inclination of interest. The launcher energy and power requirements fall in the range of 2000 MJ and 2 MW electric. This energy would be supplied by 400 modules of energy storage and magnetic coils. With a prime ...
A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).
A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).
Recent advances in nanoscience have raised interest in the minimum bit size required for classical information storage. This bit size is determined by the necessity for bistability with suppressed quantum tunnelling and energy barriers that exceed ambient temperatures. In the case of magnetic information storage, much attention has centred on molecular magnets with bits consisting of about 100 atoms, magnetic uniaxial anisotropy energy barriers of about 50?K and very slow relaxation at low temperatures. Here, we draw attention to the remarkable magnetic properties of some transition-metal dimers, which have energy barriers approaching 500?K with only two atoms. The spin dynamics of these ultrasmall nanomagnets is strongly affected by a Berry phase, which arises from quasi-degen...
The mapping of the magnetic flux bundle from the center cell to the Plasma Potential Control plates (PPC) on the end fan of the Tandem Mirror Experiment Upgrade (TMX-U), was improved by the addition of trim coils (12,000 amp-turns) on each side of each end fan next to the pump beam magnetic shields. The coils' axes are oriented perpendicular to the machine centerline. These coils made the necessary corrections to the field-line mapping, while keeping the field in the nearby pump beam magnetic shield below the saturation threshold. This paper briefly describes the problem, discusses the design as it evolved, and presents the results of the field testing. A brief description of the improvement in the machine performance is also included.
Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.
Nanocrystalline MnFe"2O"4 ferrite was prepared by using autocombustion technique (flash). The microstructure and magnetic properties are studied. The results of XRD and TEM clarified that, this ferrite is nanosized with particle size (39 nm). Magnetic measurements showed a ferromagnetic behavior with T"C = 613 K, the saturation magnetization M"s = 13.71 emu/g, remanent magnetization M"r = 0.1694 emu/g and, coercivity H"c = 25.6 Oe. Natural material, egg white used as an aqueous medium to extend prepare nanoparticles better than other chemical interesting materials.
Magnetic refrigeration uses the temperature- and field-dependence of the entropy of some magnetic materials to accomplish cooling. Because of the intrinsically high efficiency of the magnetization and demagnetization process and because of the potential for excellent heat transfer between solids and fluids, magnetic refrigerators promise to have higher efficiency than existing gas-cycle refrigerators. Many ground-based and space-based applications could benefit significantly from the cost savings implied by higher efficiency. Other attributes of these devices are high reliability and low volume and mass per unit cooling power. The development of these refrigerators is underway at several places around the world, including the Los Alamos National Laboratory. The progress to date has been encouraging but some problems have been clearly identified. The arguments for high efficiency and the problems that ...
Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is ...
We derive the exchange currents of pseudoscalar, vector, and scalar mesons from Feynman diagrams, and use them to calculate the magnetic form factors of nucleon and ?(1232). The magnetic moments and electromagnetic radii are obtained by using those form factors and the parameters determined from the masses of nucleon and ?(1232). We find the magnetic moments and electromagnetic radii of nucleon and ?(1232) can be produced very well in the extended Goldstone-Boson-exchange model in which all of pseudoscalar, vector, and scalar meson nonet are included. The magnetic moments of ?(1232) are closer to experiment values and results from lattice calculation than the results obtained by the model without other mesons except for pion and sigma.
The switching behavior of magnetic patterns prepared by ion irradiation was investigated. Co/Pt multilayers with perpendicular anisotropy and large out-of-plane coercivities 5-6 kOe were grown on electron transparent SiN windows. Regularly spaced 1 micron sized regions, were magnetically pattered via ion beam irradiation through a stencil mask. Lorentz TEM was used to observe in-situ magnetization reversal processes of irradiated regions under well-defined applied magnetic fields. When the in-plane field was increased, domain wall motion was observed, resulting in the alignment of the patterns with the direction of the applied field. The switching mechanism of the in-plane patterns was by domain wall motion.
RHIC 8 cm aperture dipole magnets and quadrupole cold masses are being built for Brookhaven National Laboratory (BNL) by Northrop Grumman Corporation at a production rate of one dipole magnet and two quadrupole cold masses per day. This work was preceded by a lengthy Technology Transfer effort which is described elsewhere. This paper describes the tooling which is being used for the construction effort, the production operations at each workstation, and also the use of trend plots of critical construction parameters as a tool for monitoring performance in production. A report on the improvements to production labor since the start of the programs is also provided. The magnet and cold mass designs, and magnetic test results are described in more detail in a separate paper.
This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).
The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.
The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...
Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.
Magnetic properties of layer ferromagnets against the thickness are investigated. Two new compounds served for studies: Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1. The Moessbauer effect and the magnetic susceptibility measurements were applied in the experiment. The Faraday method was used in magnetic measurements in fields from 1 to 9,5 kOe. The results of Moessbauer measurements show that temperature dependence of the spectra is typical for compounds with superparamagnetic properties. The magnetic fields Hsub(n) on Fe"5"7 nuclei in Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1 are similar and equal to 520+-10 kOe. Therefore it may be concluded that relaxation times of nuclear spins in these compounds are equal or close to each other. The lines of quadrupole splitting appear in spectra together at 20 K. The results of magnetic ...
We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to saturate the ...
One of the major achievements of the magnet R&D program for the Superconducting Super Collider (SSC) is the fabrication and test of a series of 20 5-cm aperture, 15-m long dipole magnet prototypes. The ramp rate sensitivity of these magnets appears to fall in at least two categories that can be correlated to the manufacturer and production batch of the strands used for the inner-coil cables. The first category, referred to as type-A, is characterized by a strong quench current degradation at high ramp rates, usually accompanied by large distortions of the multipole fields and large energy losses. The second category, referred to as type-B, is characterized by a sudden drop of quench current at low ramp rates, followed by a much milder degradation at larger rates. The multipole fields of the type-B magnets show little ramp-rate sensitivity, and the energy losses are smaller than for the type-A ...
The results of x-ray diffraction, dc magnetization, and 61Ni Moessbauer spectroscopy studies of the ternary arsenide CrNiAs are reported. This compound crystallizes in the orthorhombic Fe2P-type structure (space group P6-bar2m) with the lattice parameters a 6.1128(2) A and c = 3.6585(1) A. CrNiAs is a mean-field ferromagnet with Curie temperature TC = 171.9(1) K and the critical exponents ? 0.514(18), ? = 1.010(16), and ? = 2.922(10). The temperature dependence of the magnetic susceptibility above TC follows the modified Curie-Weiss law with a paramagnetic Curie temperature of 176.0(3) K and effective magnetic moment per transition metal atom of 2.42(1) ?B. The magnetic moment per formula unit at 4.2 K is found to be 1.114(33) ?B. The hyperfine magnetic field at 61Ni nuclei at 4.2 K of 41.5(1.0) kOe implies that the Ni atoms carry a magnetic moment of 0.15(3) ...
Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.
The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were ...
DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque on the ...
DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the crystal field torque ...
ABS>A horizontal steam generator design for the SM-2 was lysis to determine the per formance of such a steam generator under steady state operating conditions and during load transients, The configuration for this design is a two- drum unit consisting of a heat exchanger unit and separator drum interconnected by integral riser and downcomer. An analog computer was used to analyze the steam generator behavior Wring load transients. The effect of various design changes on the response of the steam generator to step chages in load was determined. The horizontal steam generator design was compared to the existing vertical steam generator design for weight, size, price, and performance. (auth)
Using the full potential linearized augmented plane wave (FLAPW) method, the magnetic properties of two-dimensional Ru and Rh monolayers (MLs) on a NiAl(001) surface have been investigated. It has been found that free standing one monolayer Ru and Rh films have ferromagnetic ground state with magnetic moments of 2.21 and 1.48 #mu#_B, respectively. The ferromagnetism is still observed even on a Ni terminated NiAl(001) surface, while no magnetic state is found on an Al terminated surface. The calculated magnetic moments of Ru and Rh atoms are 1.56 and 0.88 #mu#_B, respectively. In addition, an induced magnetic moment in surface Ni is observed. It has been found that the free standing Ru film has perpendicular magnetization to the film surface with a magnetocrystalline anisotropy (MCA) energy of 0.66 meV/atom, while an in-plane MCA energy of 0.37 meV/atom is ...
Design process of steam generator and condenser at Russian nuclear power plant type WWER-1000 is identified. The four chapter of the books are organized as nuclear power plant, types of steam generators specially horizontal steam generator, process of steam generator design and the description of condenser and its process design.
This report summarizes the results and activities funded by this three-year award. The principal goal of this project was to determine the thermal conductivity in clusters of galaxies. Intracluster plasmas possess chaotic magnetic fields. Since charged particles are constrained to move primarily along magnetic field lines, the topology of intracluster magnetic fields slows particle diffusion relative to the non-magnetized case, thereby reducing the thermal conductivity. Our first approach to this problem was to employ the static-magnetic-field approximation. In reality, intracluster magnetic field lines are constantly moving, since they are advected by turbulent intracluster motions. The turbulent velocities, however, are much smaller than the rapid speeds of thermal electrons, which make the dominant contribution to the thermal conductivity. In the static-field ...
Experimental investigations are presented which demonstrate that the weak ferromagnets are special materials of a larger group of magnets which exhibit two magnetic ordering structures. In weak ferromagnets the main order is antiferromagnetic with a small ferromagnetic component existing in addition. On the other hand, materials in which other combinations of the two basic ordering structures coexist are also known. Common to all these non-collinear spin structures is that the moment components of the two magnetic structures are orthogonal. In the weak ferromagnets this orthogonality manifests already in the paramagnetic phase as a crossover from an isotropic to an anisotropic susceptibility with respect to the applied magnetic field: at high temperatures the antiferromagnetic Curie-Weiss law of the total moment is observed while for T->Tc crossover to a second Curie-Weiss law due to the weak ...
Over the last year-and-a-half, several 4-cm-aperture, 17-m-long dipole magnet prototypes were built by Brookhaven National Laboratory (BNL) under contract with the Superconducting Super Collider (SSC) Laboratory. These prototypes are the last phase of a half-decade-long R D program, carried out in collaboration with Fermi National Accelerator Laboratory and Lawrence Berkeley Laboratory, and aimed at demonstrating the feasibility of the SSC main ring dipole magnets. They also prepare the way of the 5-cm-aperture dipole magnet program to be started soon. In this paper, we analyze the mechanical behavior of the BNL prototypes during cool-down and excitation, and we attempt to relate this behavior to the magnet features. The data reveal that the mechanical behavior is sensitive to the vertical collar-yoke interference, and that the magnets exhibited somewhat erratic changes in coil ...
The term ``dynamo'' means different things to the laboratory fusion plasma and astrophysical plasma communities. To alleviate the resulting confusion and to facilitate interdisciplinary progress, we pinpoint conceptual differences and similarities between laboratory plasma dynamos and astrophysical dynamos. We can divide dynamos into three types: 1. magnetically dominated helical dynamos which sustain a large scale magnetic field against resistive decay and drive the magnetic geometry toward the lowest energy state, 2. flow-driven helical dynamos which amplify or sustain large scale magnetic fields in an otherwise turbulent flow, and 3. flow-driven nonhelical dynamos which amplify fields on scales at or below the driving turbulence. We discuss how all three types occur in astrophysics whereas plasma confinement device dynamos are of the first type. Type 3 dynamos requires no ...
The LHC magnet tests operation team developed various innovative techniques, particularly since early 2004, to complete the superconductor magnet tests by Feb. 2007. Overall and cryogenic priority handling, rapid on-bench thermal cycling, rule-based goodness evaluation on round-the-clock basis, multiple, mashed web systems are some of these techniques applied with rigour for successful tests completion in time. This paper highlights these operation empowerment tools which had a pivotal role for success. A priority handling method was put in place to enable maximum throughput from twelve test benches, having many different constraints. For the cryogenics infrastructure, it implied judicious allocation of limited resources to the benches. Rapid On-Bench Thermal Cycle was a key strategy to accelerate magnets tests throughput, saving time and simplifying logistics. First level magnet appraisal was developed ...
Magnetic imaging in the transmission electron microscope (TEM) has been used to examine submicron elements with the aim of discovering down to what element size complex domain patterns can form. The elements were squares, circles, triangles, and pentagons in the size range 100{endash}500 nm and were made from 36 nm Co films or 8 nm Ni{sub 80}Fe{sub 20} (NiFe) with in-plane magnetization. The magnetic domain structures in these elements were imaged at high resolution using the differential phase contrast imaging mode in a TEM. Nonuniform magnetization structures were seen in the images. Vortices were present at remanence in all shapes of 36-nm-thick Co elements down to 100 nm size and in circular NiFe elements down to 116 nm diameter. Triangular NiFe elements did not have a vortex state at remanence, instead the magnetization curved round within the element but did not achieve ...
Ho{sub 2}CuTiO{sub 6} double pervoskite is synthesized by solid state reaction method and the phase formation was confirmed by X-ray diffraction. Ho{sub 2}CuTiO{sub 6} crystallizes in space group P63 cm and are isostructural in AMnO{sub 3} structure. We have investigated the effect of the presence of a magnetic ion (Ho{sup 3+}{approx}10.4{mu}{sub B}) in Ho{sub 2}CuTiO{sub 6}, on the magnetic properties, compared to that of an isostructural double perovskite containing Y-ion (non-magnetic), i.e., Y{sub 2}CuTiO{sub 6}. Magnetization measurements on Ho{sub 2}CuTiO{sub 6} showed paramagnetic moment of 0.026{mu}{sub B}/Ho at room temperature in an applied field of 7 T although no saturation is observed at room temperature, whereas, at 5 K, the paramagnetic moment was 0.3{mu}{sub B}/Ho in the same field. Since this compound is non-centrosymmetric, it is of interest to look into the possibility of realizing ...
We present an x-ray magnetic circular dichroism (XMCD) study performed on both Ho{sub 6}Fe{sub 23} and Y{sub 6}Fe{sub 23} compounds as a function of the temperature. The combined analysis of both Fe K-edge and Ho L{sub 2,3}-edge XMCD spectra recorded through the magnetic compensation transition allows us to disentangle the thermal dependence of both Fe and Ho magnetic moments in Ho{sub 6}Fe{sub 23}. In addition, contributions from Ho ions to the Fe K-edge XMCD signals and, conversely, from Fe ions to the Ho L{sub 2,3}-edge XMCD spectra have been clearly identified. These extra contributions, arising from the strong Fe(3d)-Ho(5d) hybridization, have been isolated from the spectra and correlated with the magnetic state of both Ho and Fe ions surrounding the absorbing site. The influence of these contributions to the values of the orbital and spin moments derived by using sum rule analysis is also shown.
Holmium doped barium based hexaferrites BaFe12-2xHo2xO19 with (x=0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho^3^+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (Ms), remanent magnetization (Mr) and coercivity (Hc) were observed by changing Ho^3^+ content in BaFe12-2xH...
Holmium doped barium based hexaferrites BaFe_1_2_-_2_xHo_2_xO_1_9 with (x = 0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho"3"+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (M_s), remanent magnetization (M_r) and coercivity (H_c) were observed by changing Ho"3"+ content in BaFe_1_2_-_2_xHo_2_xO_1_9 ferrites. Coercivity showed a maximum value of 2230 Oe for (x = ...
The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the observations can be explained by a thin ...
The magnetically fluidized bed (MFB) was used as the reactor in a novel semidry flue gas desulfurization (FGD) process to achieve high desulfurization efficiency. Experiments in a laboratory-scale apparatus were conducted to reveal the effects of approach to adiabatic saturation temperature, Ca/S molar ratio and applied magnetic field intensity on SO(2) removal. Results showed that SO(2) removal efficiency can be obviously enhanced by decreasing approach to adiabatic saturation temperature, increasing Ca/S molar ratio, or increasing applied magnetic field intensity. At a magnetic field intensity of 300Oe and a Ca/S molar ratio of 1.0, the desulfurization efficiency (excluding desulfurization efficiency in the fabric filter) was over 80%, while spent sorbent appeared in the form of dry powder. With the SEM, XRD and EDX research, it can be found that the increase of DC magnetic field ...
Gantries in the proton/carbon cancer therapy machines represent the major cost and are of the largest size. This report explains a new way to the gantry design. The size and cost of the gantries are reduced and their use is simplified by using the fixed magnetic field. The ''new'' gantry is made of a very large momentum acceptance non-scaling Fixed Field Alternating Gradient (FFAG) quarter and half arc beam lines. The gantry is made of combined function magnets with a very strong focusing and small dispersion function. Additional magnets with a fast response are required to allow adjustments of the beam position for different energies at the beginning of the gantry. Additional strong focusing magnets following the gantry have also to be adjustable to provide required spot size and radial scanning above the patients. The fixed field combined function ...
Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.
Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.
The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.
1. Nitric oxide generation is important in the regulation of resistance vessel tone. Until now, however, there has been no evidence of such a role for basal generation of nitric oxide in the skin microcirculation...Full Text Available
IntroductionThe aim of the study was to assess and classify incidents of electromagnetic interference (EMI) by second-generation and third-generation mobile phones on critical care...Full Text Available
Statistical data on experience gained from operation of steam generators around the world are presented, problems arising in vertical and horizontal steam generators are described, and the conditions of heattransfer tubes used in them are compared.
Results are described of a study and of the characteristics of sources of a non-equilibrium gas-discharge plasma. The plasma generators considered include glow, high frequency, and arc discharge generators. Thermodynamic, ionic, and electronic processes occurring in the plasmas are evaluated.
The general objective of the International Seminars of Horizontal Steam Generator Modelling has been the improvement in understanding of realistic thermal hydraulic behaviour of the generators when performing safety analyses for VVER reactors. The main to...
The main problems encountered during the operation of horizontal steam generators are considered. Design features of the new PGV-1000MK and PGV-1500 steam generators are analyzed.
The sharp, temperature induced, continuous valence transition in EuPd/sub 2/Si/sub 2/ is drastically changed by doping with Sn at the Si site up to 5 at.%. Only a first order valence transition occurs for a 3% Sn doped sample and the 2/sup +/ component which survives the valence transition orders magnetically at 4.2 K. No valence transition at all occurs for a 5% Sn doped sample right up to 1.9 K and magnetic ordering sets in around 30 K.
Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.
A total of 50 000 tonnes of low-carbon steel sheet has been ordered for the LHC main magnets. After three years of production, about 10 000 tonnes of steel sheet have been produced by Cockerill-Sambre Groupe Usinor. This paper gives a summary of the manufacturing process and improvements implemented as well as an overview of the difficulties encountered during this production. Preliminary statistics obtained for the mechanical and magnetic steel properties are presented. (6 refs).
Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.
A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.
CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.
We present the synthesis, magnetic and UV spectrometry of NiZn-ferrite nanofiber. The single phase of spinel ferrite was obtained at 600 {sup o}C. The NiZn-ferrite fibers fabricated by an electrospinning process were formed as a polygonal grain growth with firing temperature in fiber matrix. It appeared that the saturation magnetization (M{sub S}) of NiZn-ferrite nanofiber was dependent on Ni/Zn molar ratio which is similar to that of the inverse spinel ferrites. The NiZn-ferrite fibers showed good DNA adsorption efficiency that can be modified and utilized for DNA separation with magnetic nanofiber as a novel material in clinical applications.
The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters. (orig.)
The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters.
The DC magnetic susceptibility of the REBa_2F_7 compounds was measured by a SQUID magnetometer in the temperature range 5-300 K. Except for Eu, the other compounds show either Curie law or Curie-Weiss law with relatively small values of paramagnetic Curie temperature, #theta#_p, with effective magnetic moments in the range expected of electronic ground state of the trivalent rare earth ion with appropriate J value. The behaviour of Eu is complex. (orig.).
The magnetic field strengths of most millisecond pulsars(MSP) are about $10^{8-9}$ Gauss. The accretion induced magnetic field evolution scenario here concludes that the field decay is invesely related to the accreted mass and the minimum field or bottom field stops at about $10^{8}$ Gauss if accreted with the Eddington accretion rate, which is proportionally related with the accretion rate as $\\dot{M}^{1/2}$. The possibility of the low field $\\sim 10^{7}$ Gauss MSPs has been proposed for the future radio observation.
The problem of thermal instability of compressible, electrically conducting couple-stress fluids in the presence of a uniform magnetic field is considered. Following the linearized stability theory and normal mode analysis, the dispersion relation is obtained. For stationary convection, the compressibility, couple-stress, and magnetic field postpone the onset of convection. Graphs have been plotted by giving numerical values of the parameters to depict the stability characteristics. The principle of exchange of stabilities is found to be satisfied. The magnetic field introduces oscillatory modes in the system that were non-existent in its absence. The case of overstability is also studied wherein a sufficient condition for the non-existence of overstability is obtained. (orig.)
Magnetic behavior in three compounds RTa{sub 3}O{sub 9} (R = Nd, Eu and Ho) with defect-perovskite structures has been investigated by DC magnetic susceptibility. The susceptibility of NdTa{sub 3}O{sub 9} shows strong influence of crystal field. For EuTa{sub 3}O{sub 9} a typical Van Vleck paramagnetism has been observed. HoTa{sub 3}O{sub 9} obeys a Curie-Weiss law above 20 K. (orig.) 8 refs.
The results obtained from the magnetization, specific heat and electrical resistivity measurements on a polycrystalline sample of Pr_2Pd_3Si_5 are reported. The temperature dependence of magnetic susceptibility at low field (0.01 T) exhibits pronounced anomaly below 7 K due to antiferromagnetic ordering. The electrical resistivity and specific heat data also exhibit sharp transition at 6.6 K evidencing the onset of antiferromagnetic order. A fit to the electrical resistivity data below 6 K suggests the presence of an energy gap in magnon spectrum in the ordered state. (author)
Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.
The orbit response matrix (ORM) method [1] is applied to model the Fermilab Booster with parameters such as the BPM gains and rolls, and parameters in the lattice model, including the gradient errors and magnets rolls. We found that the gradients and rolls of the adjacent combined-function magnets were deeply correlated, preventing full determination of the model parameters. Suitable constraints of the parameters were introduced to guarantee an unique, equivalent solution. Simulations show that such solution preserves proper combinations of the adjacent parameters. The result shows that the gradient errors of combined-function magnets are within design limits.
The Compact Muon Solenoid (CMS) is one of the experiments which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN. The design field of the CMS magnet is 4 T, the magnetic length is 12.38 m and the aperture is 6.36 m. This is achieved with a 4 layer-5 module superconducting Al-stabilized coil energised at a nominal current of 20 kA. The finite element analysis (FEA) carried out is axisymmetric elasto-plastic. FEA has also been carried out on the suspension system and on the conductor. (8 refs).
Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.
Two new identical insertion devices have been designed for the Daresbury SRS. They are 2T permanent-magnet multipole wigglers that will provide high flux in the X-ray region. This paper describes the magnetic and mechanical design of the arrays of steel pole pieces and permanent-magnet blocks. Also given is the engineering design of the support structure that will cope with the very large forces present while maintaining high levels of precision in gap setting and parallelism. The engineering design has been fully assessed using finite-element techniques to predict the deflections of critical parts of the structure. These two devices are due to be installed into the SRS by the end of 1998.
The ZnO nanorods were used as a template to fabricate nickel nanoclusters by electrodeposition. The ZnO nanorod arrays act as a nano-semiconductor electrode for depositing metallic and magnetic nickel nanoclusters. The growth sites of Ni nanoclusters could be controlled by adjusting the applied potential. Under -1.15 V the Ni nanoclusters could be grown on the tips of ZnO nanorods. On increasing the potential to be more negative the ZnO nanorods were covered by Ni nanoclusters. The magnetic properties of the electrodeposited Ni nanoclusters also evolved with the applied potentials.
This paper is devoted to investigate the influences of thermal dispersion and magnetic field on a hot semi-infinite vertical porous plate embedded in a saturated Darcy-Forchheimer-Brinkman porous medium. The coefficient of thermal diffusivity has been assumed to be the sum of the molecular diffusivity and the dynamic diffusivity due to mechanical dispersion. The effects of transverse magnetic field parameter (Hartmann number Ha), Reynolds number Re (different velocities), Prandtl number Pr (different types of fluids) and dispersion parameter on the wall shear stress and the heat transfer rate are discussed.
Borrelia burgdorferi sensu lato genospecies were differentiated by PCR-based sequencing of the borrelial flagellin gene. To evaluate the usefulness of KingFisher"T"M magnetic particle processor in PCR product purification, borrelia PCR products were purified with KingFisher"T"M magnetic particle processor prior to cycle sequencing and the quality of the sequence data received was analyzed. KingFisher was found to offer a rapid and reliable alternative for borrelial PCR product purification.
The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author)
The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author).
... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...
We present results on searches for exotic particles (relativistic magnetic monopoles and WIMPs) and for UHE neutrinos, obtained with the Baikal neutrino telescope NT200.
The magnetic ordering temperature of some rare-earth-based heavy-fermion compounds is strongly pressure dependent and can be completely suppressed at a critical pressure, p{sub c}, making way for novel correlated electron states close to this quantum critical point. We have studied the clean heavy-fermion antiferromagnets CePd{sub 2}Si{sub 2} and CeIn{sub 3} in a series of resistivity measurements at high pressures up to 3.2 GPa and down to temperatures in the mK region. In both materials, superconductivity appears in a small window of a few tenths of a GPa on either side of p{sub c}. We present detailed measurements of the superconducting and magnetic temperature-pressure phase diagram, which indicate that superconductivity in these materials is enhanced, rather than suppressed, by the closeness to magnetic order. (author)
The magnetic ordering temperature of some rare-earth-based heavy-fermion compounds is strongly pressure dependent and can be completely suppressed at a critical pressure, p_c, making way for novel correlated electron states close to this quantum critical point. We have studied the clean heavy-fermion antiferromagnets CePd_2Si_2 and CeIn_3 in a series of resistivity measurements at high pressures up to 3.2 GPa and down to temperatures in the mK region. In both materials, superconductivity appears in a small window of a few tenths of a GPa on either side of p_c. We present detailed measurements of the superconducting and magnetic temperature-pressure phase diagram, which indicate that superconductivity in these materials is enhanced, rather than suppressed, by the closeness to magnetic order. (author)
Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.
... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...
A shipbuilder is using an electro-magnetic forming system (on loan from NASA) in a development program. " A modification in the design of a metal bending ...
The existence of multipole components in the dipole and quadrupole magnets is one of the factors limiting the beam stability in the RHIC operations. So, a realistic non-linear model is crucial for understanding the beam behavior and to achieve the ultimate performance in RHIC. A procedure is developed to build a non-linear model using the available multipole component data obtained from measurements of RHIC magnets. We first discuss the measurements performed at different stages of manufacturing of the magnets in relation to their current state in RHIC. We then describe the procedure to implement these measurement data into tracking models, including the implementation of the multipole feed down effect due to the beam orbit offset from the magnet center. Finally, the field quality analysis in the RHIC interaction regions (IR) is presented.
Noncollinear (NC) magnetism is common in nature, especially when there exist geometrical frustration and chemical imparity in the system. In this work we studied the NC magnetism and the response to external magnetic fields in surfaces and interfaces of transition metals by using an semi-empirical tight-binding (TB) method that parameterized to the ab initio TB-LMTO calculations. We implemented this method to study two systems. The first one is the system of 6 Mn monolayers on Fe(001) substrate. Due to the complex structure and magnetic properties of Mn, we found 23 collinear magnetic configurations but only one NC configuration. The collinear ground state has a layered antiferromagnetic (AFM) coupling which agrees with previous experiments and calculations. In the NC configuration the local AFM coupling in the Mn layers is preserved, but the surface is 90 degree coupled to the ...
The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).
Neutron diffraction and magnetometric measurements on polycrystalline samples of DyPd_2Si_2 and ErPd_2Si_2 were carried out in the temperature range from 2 to 293 K. Both compounds show tetragonal ThCr_2Si_2 type crystal structure and order at 12 K in a sine modulated magnetic structure with propagation vectors k=[0.609,0,0.155] and [0.575, 0, 0.083] respectively. The oscillatory character of magnetic order found in RPd_2Si_2 (R=Tb-Er) compounds suggests exchange interaction described by the RKKY model to be dominant, but the non-monotonic dependence of respective Neel temperatures on the number of f-electrons indicates the influence of a crystalline electric field (CEF) on the magnetic behaviour in this series. (orig.).
Samples of Fe78B13Si9 (Metglas 2605 TCA) and Fe77Cr2B16Si5 (Metglas 2605 S3A) were exposed to pulsed excimer laser irradiation at repetition rates of 15, 25 and 50Hz. The occurrence of out-of-plane magnetic anisotropy, changes in the average hyperfine magnetic field and width of the hyperfine field distribution were evidenced by transmission Mossbauer spectroscopy. The variation of the recoilless fraction with laser processing parameters was derived from the simultaneous recording of Mossbauer spectra using a stainless steel etalon as a dual absorber. Conclusions on the onset of long-range magnetic order were formulated.
The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).
Magnetization, neutron diffraction and "1"6"6Er Moessbauer measurements on ErPd_2Si_2 are reported. Below 4.8 K ErPd_2Si_2 orders AF with complex modulated magnetic structures, where the Er moments are aligned along the c-axis. At 1.5 K a squared structure with #mu#_E_r #approx# 7.8(1)#mu#_B is found while a saturation Er moment of 8.2(2)#mu#_B is inferred from the hyperfine field data. The temperature dependence of the Moessbauer spectra in the paramagnetic region is explained in the framework of a relaxation model implying excited crystal field levels. Its analysis is used to estimate the B"m_n CEF parameters. (orig.).
Magnetic characteristics of the ternary alloys TCu_2Si_2 (T = Nd, Dy, Ho, Er, and Tm) have been investigated. Magnetic susceptibility measurements were carried out between 4.2 and 150 K and in magnetic fields of 1 to 18 kOe, using a vibrating sample magnetometer. The Curie-Weiss law is followed by NdCu_2Si_2 above 30 K, by DyCu_2Si_2 and HoCu_2Si_2 above 50 K, and by ErCu_2Si_2 and TmCu_2Si_2 above 9 K. Furthermore, the Curie paramagnetic temperatures are given.
The cross-over from a magnetically ordered to a non-magnetic spin liquid state has been investigated in a series of resistance measurements under hydrostatic pressures of up to 30 kbar and at temperatures down to below 200 mK in the heavy fermion antiferromagnet CePd{sub 2}Si{sub 2}. The electrical resistivity changes dramatically with increasing pressure. Near the critical pressure, at which the magnetic ordering temperature is extrapolated to zero, it exhibits a quasi-linear variation over two orders of magnitude in temperature. This non-Fermi liquid form of {rho}(T) extends down to the onset of a new superconducting transition below 430 mK. (orig.).
The cross-over from a magnetically ordered to a non-magnetic spin liquid state has been investigated in a series of resistance measurements under hydrostatic pressures of up to 30 kbar and at temperatures down to below 200 mK in the heavy fermion antiferromagnet CePd_2Si_2. The electrical resistivity changes dramatically with increasing pressure. Near the critical pressure, at which the magnetic ordering temperature is extrapolated to zero, it exhibits a quasi-linear variation over two orders of magnitude in temperature. This non-Fermi liquid form of #rho#(T) extends down to the onset of a new superconducting transition below 430 mK. (orig.).
The magnetic and magnetostrictive properties of polycrystalline Co1-xMnxFe2O4 (0 ? x ? 0.4) have been studied. Although the Curie temperature decreases continuously with increasing concentration of Mn, the magnetization remains high up to x = 0.3 and unexpectedly low coercivity is observed for this composition showing an unusual magnetostrictive behaviour. This composition shows a relatively larger magnetostriction at low fields. Moreover, the strain derivative which is the slope of the magnetostriction curve at low magnetic fields is almost doubled and the field at which maximum magnetostriction is observed is reduced to almost half for 30% of Mn substitution. The results show that x ? 0.3 in Co1-xMnxFe2O4 is an optimum composition with superior magnetostrictive properties for many applications.
We present a systematic study of the magnetization, Hall effect and specific heat on single crystals of Mn{sub 4}Si{sub 7}. Curie-Weiss law is observed above 43 K. At low-temperature moments order in an anisotropic helical state and are aligned above 1 T. We observe an anomalous Hall effect in both {rho}{sub H} vs. B and in R{sub H} vs. T curves and a field dependence of the low T specific heat due to spin fluctuations. The magnetic moments (p{sub eff} and p{sub sat}) are the lowest reported for similar itinerant magnetic systems, this suggests that Mn{sub 4}Si{sub 7} is a good candidate to observe critical quantum fluctuations expected for a marginal Fermi liquid.
We report electronic and magnetic structure of arsenic-doped manganese clusters from density-functional theory using generalized gradient approximation for the exchange-correlation energy. We find that arsenic stabilizes manganese clusters, though the ferromagnetic coupling between Mn atoms are found only in Mn$_2$As and Mn$_4$As clusters with magnetic moments 9 $\\mu_B$ and 17 $\\mu_B$, respectively. For all other sizes, $x=$ 3, 5-10, Mn$_x$As clusters show ferrimagnetic coupling. It is suggested that, if grown during the low temperature MBE, the giant magnetic moments due to ferromagnetic coupling in Mn$_2$As and Mn$_4$As clusters could play a role on the ferromagnetism and on the variation observed in the Curie temperature of Mn-doped III-V semiconductors.
The current paper continues the analysis of a completely novel method of fluid manipulation technology in micro-fluidics systems, inspired by nature, namely by the mechanisms found in ciliates. More information on this subject can be found at http://www.hitech-projects.com/euprojects/artic/. In order to simulate the drag forces acting on an array of artificial cilia, we have developed a computer code that is based on fundamental solutions of Stokes flow in a semi-infinite domain. The actuation mechanism consists of a bi-directional rotating excitation magnetic field. The magnetization induced by the magnetic field was calculated in a separate routine based on the Integral Nonlinear Equations Approach with 1D discretization of wire (cilium). Time averaged x-coordinate mass flow rates, strea...
These notes present a pedagogical introduction to magnetic monopoles, supersymmetry and dualities in gauge theories. They are based on lectures given at the X Jorge Andre Swieca Summer School on Particles and Fields. (author)
The magnetic properties of the superconductive materials HoBa/sub 2/Cu/sub 3/O/sub z/ and YBa/sub 2/Cu/sub 3/O/sub z/ have been measured and compared. Both had superconductive transition temperatures T/sub c/ in low magnetic fields near 90 K and exhibited nearly complete magnetic-flux exclusion. The susceptibility of the Ho-based materials followed a Curie-Weiss law both above and below T/sub c/. These results give clear experimental evidence for a nearly complete decoupling of the magnetic and superconductive layers, demonstrating that the superconductivity is highly anisotropic.
... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...
High-field magnetization properties of single crystalline CeRh{sub 2}Si{sub 2} and CePd{sub 2}Si{sub 2} were investigated. Two-step metamagnetic transition (H{sub c1}=25.4 T and H{sub c2}=26.0 T) was observed in the case of CeRh{sub 2}Si{sub 2}, whereas no anomaly was found in the magnetization process of CePd{sub 2}Si{sub 2} up to 28 T. The mean field analysis has shown that CeRh{sub 2}Si{sub 2} is quite anisotropic compared to CePd{sub 2}Si{sub 2}, which results in the sharp contrast between the magnetization processes of the two compounds.
High-field magnetization properties of single crystalline CeRh_2Si_2 and CePd_2Si_2 were investigated. Two-step metamagnetic transition (H_c_1=25.4 T and H_c_2=26.0 T) was observed in the case of CeRh_2Si_2, whereas no anomaly was found in the magnetization process of CePd_2Si_2 up to 28 T. The mean field analysis has shown that CeRh_2Si_2 is quite anisotropic compared to CePd_2Si_2, which results in the sharp contrast between the magnetization processes of the two compounds
MAGNETIC FORMING BERYLLIUM COIL ASSEMBLY. By. J. W. Rogers, D. D. Wier, and M. E. Davis. Department of Electrical Engineering. Mississippi State University ...
We investigate the effects of the velocity-dependent force on the magnetic form factors and magnetic moments of odd-Z nuclei. The form factors are calculated with the harmonic-oscillator wavefunctions. It is found that the contributions of the velocity-dependent force manifest themselves in the very large momentum transfer region (q?4 fm-1). In the low and medium q region the contributions of the velocity-dependent force are very small compared with those without this force. However, in the high-q region the contributions of the velocity-dependent force are larger than the normal form factors. The diffraction structures beyond the existing experimental data are found after the contributions of the velocity-dependent force are included. The formula of the correction to the single particle magnetic moment due to the velocity-dependent force is reproduced exactly in the long-wavelength limit (q=0) of the M1 form factor. ...
To study the nanoscale electronic order in strongly correlated electron systems and vortex states in high-Tc superconductors in high magnetic fields, we have developed scanning tunneling microscopy (STM) for the 18 T cryocooled superconducting magnet (18T-CSM). The test results of the STM operation in the 18T-CSM at room temperature indicate that our STM has a good atomic resolution up to 18 T when we use the nonmagnetic vibration-isolation table which reduce the vibration noise from the cryocoolers of the 18T-CSM. In this paper, we report on the design of the high-field STM system for large-scale magnets and its performance.
The crystal structure of R/sub 6/Cu/sub 8/Sn/sub 8/ compounds (R=Gd, Tb, Dy, Ho, Er, Tm) is determined and their magnetic susceptibility is measured in the temperature range 78-293 K. The structure of the compounds is isotypical with the Gd/sub 6/Cu/sub 8/Ge/sub 8/ type (space group Immm, Z=1). The magnetic susceptibility of the R/sub 6/Cu/sub 8/Sn/sub 8/ compounds is described by the Curie-Weiss law. Effective magnetic moments of R/sub 6/Cu/sub 8/Sn/sub 8/ compounds (R=Gd, Tb, Dy, Ho, Er, Tm) are in good agreement with theoretical values for free R/sup 3 +/ ions.
High Cycle Fatigue Initiative Workshop -Active Vibration. Control/Engine. Health Monitoring Session December 10,. 1996. The presentation was titled "Active ...