WorldWideScience
1

Tritium bioassay and dosimetry at a CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.

1996-07-01

2

Korea's Team CANDU  

International Nuclear Information System (INIS)

KEPCO (Korean Electric Power Corp.) with the support of AECL and other Korean and Canadian subcontractors has created a strong multi-company team to execute design and construction of the Wolsung-2 CANDU 6 power plant. Key concepts of the project team are: 1. KEPCO is the project manager, and AECL is the major engineering and supply contractor; 2. Significant participation by Korean companies in design work in Canada and Korea; 3. Significant manufacturing in both Canada and Korea; 4. Construction by Korean contractors. Key concepts of the Wolsung 2 design are: 1. Evolutionary improvement of the Wolsung-1 plant which balances proven technology and necessary design improvements including current codes and standards. 2. Sharing some structures with the Wolsung-1 plant. This paper describes the successful establishment and operation of the complex project interfaces along with the ...

1992-06-07

3

A study for good regulation of the CANDU's in Korea  

Energy Technology Data Exchange (ETDEWEB)

The objective of project is to derive the policy recommendations to improve the efficiency of CANDU plants regulation. These policy recommendations will eventually contribute to the upgrading of Korean nuclear regulatory system and safety enhancement. During the second phase of this 2 years study, following research activities were done. Review the technical basis and framework of the new Canadian Regulation System and IAEA. Analysis on the interview of Wolsung operation staffs to identify important safety issues and regulation problems experienced at operation. Providing a plan of CANDU regulation system enhancement program.

2002-03-15

4

Assessment of radiological safety of Wolsung site at site boundary considering crack impact  

British Library Electronic Table of Contents (United Kingdom)

The number of spent fuel storage facilities in the world continues to increase because of "Wait and See" policies and delay of a permanent disposal plan. The temporary spent fuel storage concept is changing to a pre-disposal storage concept. Strengthened safety concepts are required for expanded spent fuel storage facilities and sites. The Korea Hydro and Nuclear Power Company is planning to construct a reinforced concrete MACSTOR-400 facility at Wolsung. In concrete dry spent fuel storage structures, cracks can occur due to radiant heat and environmental chloride. The likelihood of cracking increases over time. Research on changes in shielding performance from one collinear crack in the surface of a concrete facility has been carried out. However there is no research about public radiolog...

2010-01-01

5

CANDU licensing in Korea : status review and future requirements  

International Nuclear Information System (INIS)

The licensing status and procedures, regulatory framework, and current safety issues of CANDU type reactors, Wolsong units 2, 3 and 4 are examined. Licensing difficulties and lessons learned during the safety review of Wolsong 2, 3 and 4 and future requirements are also summarized. The review was conducted, not only to confirm the design adequacy with respect to the domestic atomic laws and regulatory requirements of the vendor country, Canada, but also to reflect into the design the lessons learned from the regulatory experiences of operating Wolsong I to enhance the safety as high as practically possible. Safety issues observed during the licensing review, such as containment integrity, fuel channel integrity, etc., are summarized. Several efforts have been conducted to harmonize the Canadian regulations with the Korean ones by establishing domestic regulatory positions and guidelines. For example, the utility was requested to produce the ...

1998-05-03

6

Integrated plant information technology design support functionality  

Energy Technology Data Exchange (ETDEWEB)

This technical report was written as a result of Integrated Plant Information System (IPIS) feasibility study on CANDU 9 project which had been carried out from January, 1994 to March, 1994 at AECL (Atomic Energy Canada Limited) in Canada. From 1987, AECL had done endeavour to change engineering work process from paper based work process to computer based work process through CANDU 3 project. Even though AECL had a lot of good results form computerizing the Process Engineering, Instrumentation Control and Electrical Engineering, Mechanical Engineering, Computer Aided Design and Drafting, and Document Management System, but there remains the problem of information isolation and integration. On this feasibility study, IPIS design support functionality guideline was suggested by evaluating current AECL CAE tools, analyzing computer aided engineering task and work flow, investigating request for implementing integrated computer aided engineering ...

1996-06-01

7

Development of PHWR fuel fabrication in Korea  

Energy Technology Data Exchange (ETDEWEB)

Korea Advanced Energy Research Institute (KAERI) started a research project to develop the PHWR (CANDU) nuclear fuel fabrication technology in 1981. Based on the results of the intensive developmental work, several prototype fuel bundles were fabricated and tested in the Hot Test Loop at KAERI continuously in 1983 and 1984. After that, irradiation test and post-irradiation examination were carried out for two KAERI-made fuel bundles at Chalk River Nuclear Laboratories in Canada in 1984. Since the results of in-pile and out-of-pile tests with prototype fuel bundles proved to be satisfactory, 48 additional fuel bundles were loaded in Wolsung reactor (CANDU) in 1984 and 1985, and all of them were discharged without a defect after excellent performance in the power reactor. In 1985, the Korean government decided that KAERI supplies all the fuel necessary for the Wolsung reactor. For the mass production of nuclear fuel bundle, ...

1988-01-01

8

Experience of HWR nuclear fuel fabrication technology development in Korea  

Energy Technology Data Exchange (ETDEWEB)

Since January, 1981, the project of development of nuclear fuel fabrication technology for Wolsung reactor (CANDU type) was undertaken by KAERI(Korea Advanced Energy Research Institute) and successfully fulfilled with loading 24 fuel bundles made by KAERI in Wolsung reactor in September, 1984. On the basis of this accumulated technology and experience, mass production plan to supply all the nuclear fuels for Wolsung reactor is under way. In this presentation, the Korean experience in the development of the nuclear fuel fabrication technology, safety and performance evaluation of KAERI fuel and the results of irradiation of KAERI fuels in Wolsung reactor will be described.

1985-07-01

9

Experience of HWR nuclear fuel fabrication technology development in Korea  

International Nuclear Information System (INIS)

Since January, 1981, the project of development of nuclear fuel fabrication technology for Wolsung reactor (CANDU type) was undertaken by KAERI(Korea Advanced Energy Research Institute) and successfully fulfilled with loading 24 fuel bundles made by KAERI in Wolsung reactor in September, 1984. On the basis of this accumulated technology and experience, mass production plan to supply all the nuclear fuels for Wolsung reactor is under way. In this presentation, the Korean experience in the development of the nuclear fuel fabrication technology, safety and performance evaluation of KAERI fuel and the results of irradiation of KAERI fuels in Wolsung reactor will be described.

1985-10-29

10

N-Nitrosamine in Korean Beer  

KoreaScience (Korea)

Full Text Available

1996-06-01

11

Development of QA/QC technology in Korea  

International Nuclear Information System (INIS)

KAERI (Korea Advanced Energy Research Institute) has performed research to develop the fabrication technology of CANDU nuclear fuel since 1981. Based on the satisfactory results of in-pile and out-of-pile tests of prototype nuclear fuel and the outstanding performance of 48 KAERI-made nuclear fuels in Wolsung(CANDU) power reactor, Korean government decided KAERI to supply all the nuclear fuels for Wolsung from 1988. In order to guarantee the safety and performance of nuclear fuel manufactured in mass production scale, well-organized quality assurance system and appropriate quality control techniques should be established. To establish the QA system, KAERI reviewed various QA standards and decided to establish QA system based on the 10 CFR 50 Appendix B. Quality control techniques was also revised to fit the mass production even though quality inspection techniques have already been developed during research period. By ...

1986-10-06

13

An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)  

International Nuclear Information System (INIS)

Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 streams; and in the third step the tritium is packaged for ...

2007-11-07

14

The development of PHWR fuel fabrication in Korea  

International Nuclear Information System (INIS)

Korea Advanced Energy Research Institute (KAERI) started a research project to develop the PHWR (CANDU) nuclear fuel fabrication technology in 1981. Based on the results of the intensive developmental work, several prototype fuel bundles were fabricated and tested in the Hot Test Loop at KAERI continuously in 1983 and 1984. After that, irradiation test and post-irrradiation examination were carried out for two KAERI-made fuel bundles at Chalk River Nuclear Laboratories in Canada in 1984. Since the results of in-pile and out-of-pile tests with prototype fuel bundles proved to be satisfactory, 48 additional fuel bundles were loaded in Wolsung reactor (CANDU) in 1984 and 1985, and all of them were discharged without a defect after excellent performance in the power reactor. In 1985, the Korean government decided that KAERI supplies all the fuel necessary for the Wolsung reactor. For the mass production of nuclear fuel bundle, ...

1987-09-07

18

Korean experience in CANDU-PHWR operation  

Science.gov (United States)

Among KEPCO's 9 nuclear power units, Korea Nuclear Unit No. 3, the Wolsung Nuclear Power Plant is the only CANDU-PHWR Unit, while the rest of 8 others are PWR units. The unit was designed by Atomic Energy of Canada, Ltd. of Canada, who also performed overall project management for the plant construction under the provisions and arrangement of the relevant contracts. The gross electrical output of the plant is 678.7 MWe and thermal output of the reactor is 2061 MWth. While these figures lead to lower plant efficiency than LWR counterparts, unit energy cost for fuel is more favorable than LWRs because natural uranium is utilized for the fuel bundles, some of which are already being fabricated domestically. Annual capacity factors for 1983 and 1984 could have been improved, if two major planned outages for the modification works on steam generator internals and one major forced outage from the heavy water spill incident could be eliminated. The heavy water ...

1988-01-01

19

Clinical Characteristics and Outcomes of Cataract Surgery in Highly Myopic Koreans  

UK PubMed Central (United Kingdom)

PurposeTo evaluate the clinical characteristics and outcomes of cataract surgery in highly myopic Korean subjects.MethodsWe retrospectively reviewed...Full Text Available

2011-04-01

42

CANDU year in review  

Energy Technology Data Exchange (ETDEWEB)

The commissioning of four CANDU-600 reactors is discussed, with mention of some design features. The four are Point Lepreau, Gentilly-2, Wolsung and Cordoba reactors. The commissioning of Pickering-5 is also mentioned, and so are some events affecting other CANDU reactors.

1983-01-01

43

Regulatory experience on safety system instrument uncertainty of Wolsong units  

International Nuclear Information System (INIS)

This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by ...

2001-05-01

44

Systems analysis of the CANDU 3 Reactor  

International Nuclear Information System (INIS)

This report presents the results of a systems failure analysis study of the CANDU 3 reactor design; the study was performed for the US Nuclear Regulatory Commission. As part of the study a review of the CANDU 3 design documentation was performed, a plant assessment methodology was developed, representative plant initiating events were identified for detailed analysis, and a plant assessment was performed. The results of the plant assessment included classification of the CANDU 3 event sequences that were analyzed, determination of CANDU 3 systems that are ''significant to safety,'' and identification of key operator actions for the analyzed events.

45

A study to develop the domestic functional requirements of the specific safety systems of CANDU  

Energy Technology Data Exchange (ETDEWEB)

The present research has been made to develop and review critically the functional requirements of the specific safety systems of CANDU such as SDS-1, SDS2, ECCS, and containment. Based on R documents for this, a systematic study was made to develop the domestic regulation statements. Also, the conventional laws are carefully reviewed to see the compatibility to CANDU. Also, the safety assessment method for CANDU was studied by reviewing C documents and recommendation of IAEA. Through the present works, the vague policy in the CANDU safety regulation is cleaning up in a systematic form and a new frame to measure the objective risk of nuclear power plants was developed.

2003-03-15

46

A study to develop the domestic functional requirements of the specific safety systems of CANDU  

Energy Technology Data Exchange (ETDEWEB)

The present research has been made to develop and review critically the functional requirements of the specific safety systems of CANDU such as SOS-1, SOS-2, ECCS and containment. Based on R documents for this, a systematic study was made to develop the domestic regulation statements. Also, the conventional laws are carefully reviewed to see the compatibility to CANDU. Also, the safety assessment method for CANDU was studied by reviewing C documents and recommendation of IAEA. Through the present works, the vague policy in the CANDU safety regulation is cleaning up in a systematic form and a new frame to measure the objective risk of nuclear power plants was developed.

2001-03-15

47

Non-invasive Parameters Predicting Bladder Outlet Obstruction in Korean Men with Lower Urinary Tract Symptoms  

UK PubMed Central (United Kingdom)

The goal of this study was to evaluate the clinical and urodynamic features in Korean men with lower urinary tract symptoms (LUTS) and to determine non-invasive parameters for predicting bladder outlet...Full Text Available

2010-02-01

48

Identifying barriers to Papanicolaou smear screening in Korean women: Korean National Health and Nutrition Examination Survey 2005  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to provide a nationwide analysis on barriers to cervical cancer screening in Korea.MethodsData used for this study...Full Text Available

2010-06-01

49

Theater Combat Search and Rescue  

Science.gov (United States)

... Also introduced was the SA- 16 Albatross, an amphibian seaplane used to rescue aviators who ditched in the seas around the Korean peninsula. ...

1993-05-06

58

Effects of gamma irradiation on physiological effectiveness of Korean medicinal herbs  

Energy Technology Data Exchange (ETDEWEB)

Effects of gamma irradiation on the physiological effectiveness of Korean medicinal herbs were investigated. The physiological effectiveness including antioxidant and anticomplement function, nitrite scavenging and electron donating ability of Korean medicinal herbs by gamma irradiation at 10 kGy did not differ from that of the nonirradiated control.

1999-03-01

59

General requirements for concrete containment structures for CANDU nuclear power plants  

International Nuclear Information System (INIS)

This standard provides the general requirements used in the design, construction, testing, and commissioning of concrete containment structures for CANDU nuclear power plants designated as class containment and is directed to the owners, designers, manufacturers, fabricators, and constructors of the concrete components and parts.

2006-02-01

60

Final Report of ''On-the-Job Training'' on the CANDU Reactor.  

Science.gov (United States)

This is the final Report for the technical ''on-the-job traning'' for the Wolsung CANDU nuclear power plant which is the first Pressurized Heavy Water Reactor setting up in Korea. The technical ''on-the-job traning'' was established to increase the capabi...

1983-01-01

61

CANDU 6 operating experience  

International Nuclear Information System (INIS)

The CAMDU 6 reactor has an international reputation as one of the world's best performing and safe reactors. CANDU 6 reactors are consistently ranked in the world's top 10 for annual and lifetime performance. Six CANDU 6 units are currently in operation in four continents; in Quebec, New Brunswick, South Korea, Argentina and Romania. There are another two CANDU 6 units currently under construction at wolsong, in Korea which ore scheduled to go into service in 1998 and 1999 respectively. A second CANDU 6 unit is currently being considered for Romania. The construction of two CANDU 6 units at Qinshan, in China, is now underway. The performance of the four first-generation CANDU 6 plants, which have now been in service for 15 years, continue to show very good performance, with capacity factors on average since in-service of over 85%. The annual capacity factor of ...

1998-03-23

62

Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event  

International Nuclear Information System (INIS)

In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. ...

2001-10-01

63

The ageing of CANDU steam generator due to localized corrosion  

International Nuclear Information System (INIS)

The principal types of corrosion are presented which can occur in CANDU steam generator. There are also presented the operation conditions, the specifications referring to the water chemistry and the construction materials of Steam Generator, the factors that have a great influence on the corrosion behaviour during the whole exploitation period of this equipment. The most important elements of CANDU Steam Generator ageing management program are also discussed. (R. P.)

2001-09-17

64

Review on the status of solid radwaste management in Korean NPPs  

International Nuclear Information System (INIS)

To minimize the low and intermediate-level solid radwaste volume, the reduction efforts were persisted in Korean NPPs. As a result, annual average waste volumes were reduced to 194 drums per unit at last year. In this paper we confirmed 250 drums/unit-yr, EPRI URD management goal, and management condition for solid radwaste volume. Also, through the sample assessment of specific Korean NPP opened to the public, we could make sure that the prediction of saturation year for interim storage facility is fully suitable.

2003-10-01

65

The advanced CANDU reactor: The next step in safety and economics  

International Nuclear Information System (INIS)

The Advanced CANDU Reactor (ACR"T"M) is the 'Next Generation' CANDU"R reactor, aimed at safe, reliable power production at a capital cost significantly less than that of current reactors such as the very successful CANDU 6 reactors (e.g., Wolsong 1-4). The Wolsong 1-4 units are being joined by the Qinshan Phase 3 units in China as the current successful examples of CANDU technology. The ACR design builds on this knowledge base, adding a selected group of innovations to obtain substantial cost reduction while retaining a proven design basis. The ACR maximizes the use of components and equipment applications that are well proven through CANDU and other nuclear experience. Joint development of equipment designs and specifications with manufactures has been emphasized. Similarly, the ACR design emphasizes constructability, and takes advantage of inherent CANDU ...

2003-04-01

66

CANDU 9 - the CANDU product to meet customer and regulator requirements now and in the future  

Energy Technology Data Exchange (ETDEWEB)

CANDU reactors developed under Canadian licensing regulations that placed the primary responsibility for safety on the licensee. The Atomic Energy Control Board (AECB), Canada's nuclear regulatory agency, state in their regulations what is expected in terms of safety performance so that designers are free to propose the best means of meeting this performance. This goal-oriented approach, besides encouraging innovation, allowed CANDU to be licensed in other jurisdictions. The latest design - the large, single unit, CANDU 9 - explicitly incorporates licensability in Canada through a formal AECB review of the design; lessons learned from licensing CANDU 6 in Asian countries, particularly with Wolsong 2, 3 and 4 in Korea, and more recently with Qinshan in China; utility requirements for modem evolutionary plants; and emerging international standards for safety, sponsored or issued by the IAEA. By ...

1998-07-01

67

CANDU 9 - the CANDU product to meet customer and regulator requirements now and in the future  

International Nuclear Information System (INIS)

CANDU reactors developed under Canadian licensing regulations that placed the primary responsibility for safety on the licensee. The Atomic Energy Control Board (AECB), Canada's nuclear regulatory agency, state in their regulations what is expected in terms of safety performance so that designers are free to propose the best means of meeting this performance. This goal-oriented approach, besides encouraging innovation, allowed CANDU to be licensed in other jurisdictions. The latest design - the large, single unit, CANDU 9 - explicitly incorporates licensability in Canada through a formal AECB review of the design; lessons learned from licensing CANDU 6 in Asian countries, particularly with Wolsong 2, 3 and 4 in Korea, and more recently with Qinshan in China; utility requirements for modem evolutionary plants; and emerging international standards for safety, sponsored or issued by the IAEA. By combining ...

1998-05-03

68

The Epidemiology of Cosmetic Treatments for Corneal Opacities in a Korean Population  

UK PubMed Central (United Kingdom)

PurposeTo describe etiologies and clinical characteristics of corneal opacities leading patients to seek cosmetic treatments.MethodsThe medical records...Full Text Available

2010-06-01

71

The Small Rice Bowl-Based Meal Plan was Effective at Reducing Dietary Energy Intake, Body Weight, and Blood Glucose Levels in Korean Women with Type 2 Diabetes Mellitus  

UK PubMed Central (United Kingdom)

BackgroundThe typical Korean diet includes rice, which is usually served in a rice bowl. We investigated the effects of a meal plan using rice bowls of varying sizes on dietary energy...Full Text Available

2010-12-01

72

The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients  

UK PubMed Central (United Kingdom)

ObjectiveWe wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients.Materials...Full Text Available

2011-03-01

73

Effects of gamma irradiation on microbial contamination and extraction yields of Korean medicinal herbs  

Energy Technology Data Exchange (ETDEWEB)

Effects of gamma irradiation on hygienic quality and extraction yields in twenty-one kinds of Korean medicinal herbs were investigated. Gamma irradiation at 5-10 kGy inactivated contaminating microorganisms. The total extraction yield in fifteen kinds of the investigated medicinal herbs increased by 5-25% by a dose of 10 kGy. (author)

2000-01-01

74

Comparison of the Standards applied to Instrumentation and Control Systems for Nuclear Power Stations in Korea and Russia  

Energy Technology Data Exchange (ETDEWEB)

This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions and requirements in ...

2005-04-15

75

Development of a best estimate auditing code for CANDU thermal hydraulic safety analysis  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicted with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model ...

2001-03-01

76

Leak sealing on ancillary cooling circuits of CANDU reactors  

International Nuclear Information System (INIS)

This paper discusses the remote plugging of leaks in inaccessible pipework, with main reference to small leaks which frequently appear in ancillary cooling water circuits of nuclear reactors. Initially developed to cure problems of the pre-stressed concrete pressure vessels of UK reactors, the ZORIC sealant has been used to repair leaking biological shield pipework on six CANDU reactors. ZORIC is based on a water-soluble epoxy resin and an aqueous suspension of a refined mineral clay. This paper describes the evolution of the sealant, the qualification and testing program, and their application to CANDU reactor systems. 2 refs., 6 figs.

1992-11-22

77

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

78

Review of calculational models for the performance of CANDU-type nuclear fuel element and parametic study on the fuel performance  

International Nuclear Information System (INIS)

The LWR fuel performance analysis computer code, FRAPCON-1, are evaluated to investigate the performance of CANDU fuel elements loaded in Wolsung-1 reactor. The FRAPCON-1 models of neutron flux depression in fuel and of fuel-to-cladding heat transfer are modified, and the validity of fission gas release model for CANDU fuel is evaluated. And the heavy water properties are provided in calculating the heat transfer coefficient between cladding and coolant. By using the modified code, FRAPCON-1-CSK, the sensitivity studies are carried out for Wolsung-1 fuel element design parameters. The performance analysis is also performed for Wolsung-1 fuel elements. The calculated results are discussed in terms of LWR fuel design criteria because of unavailability of CANDU fuel design criteria. (Author).

1983-01-01

79

A bibliography of AECL publications on reactor safety  

International Nuclear Information System (INIS)

AECL Publications on Reactor Safety in CANDU Reactors are listed in this bibliography. The listing is chronological and the accompanying index is by subject. The bibliography will be brought up to date annually. (auth).

1995-05-08

80

The relationship between periodontitis and metabolic syndrome among a Korean nationally representative sample of adults  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aims: The aim of this study was to examine whether metabolic syndrome (MS) is associated with periodontitis in a representative sample of Korean adults, who were involved in the Fourth Korea National Health and Nutrition Examination Survey (KNHANES). Materials and Methods: A total of 7178 subjects over the age of 19 years who participated in KNHANES were examined. MS was defined as the definition proposed by the National Cholesterol Education Program Adult Treatment Panel III and the abdominal obesity cut-off line based on Korean Society for the Study of Obesity. The periodontal status was assessed by the Community Periodontal Index. Multivariate logistic regression analysis was carried out adjusting for the sociodemographics, oral health behaviours and status, and health behaviou...

2011-01-01

81

Recent strategy and progress in Korean nuclear PLIM program  

International Nuclear Information System (INIS)

The strategy for the Korean nuclear power plant lifetime management (PLIM) program, which has been developed over the last 3 years, is introduced, together with descriptions of recent events and related maintenance activities. This leading Korean PLIM project has been focused on such areas as a plant data survey, screening and prioritization of systems, structures and components (SSCs), aging evaluation of major components, economic analysis and regulatory issues. The current status is outlined in terms of major tasks including aging evaluation of 13 major components. The future long-term plan which eventually aims at maximizing the economic benefit for both the utility and its customers is presented. Also described is the technical development required for plant life extension. (orig.).

1996-05-08

82

Discrimination of Korean ginseng (Panax ginseng) roots using rapid resolution LC-QTOF/MS combined by multivariate statistical analysis  

British Library Electronic Table of Contents (United Kingdom)

Korean ginseng (Panax ginseng C.A. Meyer) contains several types of saponins and ginsenosides, which are usually considered the major active components of ginseng. The types and quantities of saponins found in ginseng may differ depending on the region of cultivation. As a result, ginsengs produced in different areas of Korea have been unintentionally mislabeled and/or confused by Korean herbal markets owing to their complicated plant sources. Another concern is that 4- and 6-year-old ginseng roots, traditionally prescribed for different medicinal purposes, can vary in total saponin contents. Therefore, it is necessary to establish a reliable method for distinguishing different cultivation regions and ages of ginseng roots. A rapid resolution liquid chromatography-quadruple time of flight ...

2011-01-01

83

Wolsung-1 nuclear power plant  

International Nuclear Information System (INIS)

The Wolsung-1 CANDU 600 MWe plant is now in operation. This paper provides an update on the design, construction and commissioning progress reported at last year's conference. The accomplishments of the past year are highlighted with emphasis on how the station has been commissioned in preparation for commercial service and on the skills that were dedicated to the completion of the project. The paper also deals with some of the features of the CANDU 600 MWe Nuclear Power Plant that make it viable for export.

1977-06-05

84

Two dimensional analysis for equilibrium core of CANDU-PHWR  

Energy Technology Data Exchange (ETDEWEB)

The WBURN (2-D, 2-group, coarse mesh) code is developed to analyze the equilibrium core characteristics of CANDU-PHWR. The equilibrium characteristics of Wolsung reactor computed by using WBURN are compared with the values given in the Wolsung FSR. The changes of equilibrium core characteristics caused by the variation of design parameters for operating conditions are also investigated. The numerical results indicate that the average discharge irradiation in the Wolsung reactor can be increased up to about 5%.

1983-06-01

85

Two dimensional analysis for equilibrium core of CANDU-PHWR  

International Nuclear Information System (INIS)

The WBURN (2-D, 2-group, coarse mesh) code is developed to analyze the equilibrium core characteristics of CANDU-PHWR. The equilibrium characteristics of Wolsung reactor computed by using WBURN are compared with the values given in the Wolsung FSR. The changes of equilibrium core characteristics caused by the variation of design parameters for operating conditions are also investigated. The numerical results indicate that the average discharge irradiation in the Wolsung reactor can be increased up to about 5%. (Author).

1983-01-01

86

Nuclear Fuel Element Design and Thermal-Hydraulic Analysis of Wolsung-1, 600 MWe CANDU-PHWR (Part II). Thermal-Hydraulic Analysis.  

Science.gov (United States)

The main objective of the present thermal hydraulic analysis is to determine the thermal hydraulic characteristics of Wolsung-1 600 MWe CANDU-PHW reactor under normal operation. This is to verify and expedite the development of the nuclear fuel design and...

1982-01-01

87

FMDP Reactor Alternative Summary Report: Volume 2 - CANDU heavy water reactor alternative  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy Office of Fissile Materials Disposition (DOE/MD) initiated a detailed analysis activity to evaluate each of ten plutonium disposition alternatives that survived an initial screening process. This document, Volume 2 of a four volume report, summarizes the results of these analyses for the CANDU reactor based plutonium disposition alternative.

1996-09-01

88

The experience of obsolete item identification and solution in CANDU NPPs  

International Nuclear Information System (INIS)

Design and procurement of equipment for nuclear power plant took place in late 1970's. A large number of originally installed equipment is obsolete. The manufacturer's do not support their products or have discontinued their production due to technological evolutions or lack of product demand. Lack of spares affects the performance of obsolete equipment and has a negative impact on plant safety and plant production. A proactive approach to address obsolescence is necessary to ensure critical spares are always available when needed. This is an ongoing effort and requires a program to be in place to resolve immediate and longterm issues. A cross-functional team with adequate external exposure is needed to administer the obsolescence program. CANDU utilities and CANDU Owners Group(COG) has taken initiatives to identify lack of equipment spares in the members' plant. The equipment replacement information collected from each ...

2010-10-01

89

Progress of the DUPIC Fuel Compatibility Analysis (IV) - Fuel Performance  

International Nuclear Information System (INIS)

This study describes the mechanical compatibility of the direct use of spent pressurized water reactor (PWR) fuel in Canada deuterium uranium (CANDU) reactors (DUPIC) fuel, when it is loaded into a CANDU reactor. The mechanical compatibility can be assessed for the fuel management, primary heat transport system, fuel channel, and the fuel handling system in the reactor core by both the experimental and analytic methods. Because the physical dimensions of the DUPIC fuel bundle adopt the CANDU flexible (CANFLEX) fuel bundle design which has already been demonstrated for a commercial use in CANDU reactors, the experimental compatibility analyses focused on the generation of material property data and the irradiation tests of the DUPIC fuel, which are used for the computational analysis. The intermediate results of the mechanical compatibility analysis have shown that the integrity of the DUPIC fuel is ...

1995-06-04

90

Fuel bundle geometry and composition influence on coolant void reactivity reduction in ACR and CANDU reactors  

International Nuclear Information System (INIS)

It is very well known that the CANDU reactor has positive Coolant Void Reactivity (CVR), which is most important criticisms about CANDU. The most recent innovations based on using a thin absorbent Hafnium shell in the central bundle element were successfully been applied to the Advanced CANDU Reactor (ACR) project. The paper's objective is to analyze elementary lattice cell effects in applying such methods to reduce the CVR. Three basic fuel designs in their corresponding geometries were chosen to be compared: the ACR-1000TM, the RU-43 (developed in INR Pitesti) and the standard CANDU fuel. The bundle geometry influence on void effect was also evaluated. The WIMS calculations proved the Hafnium absorber suitability (in the latest 'shell design') to achieve the negative CVR target with great accuracy for the ACR-1000 fuel bundle design than for the other two projects. (authors)

2009-05-27

91

Evaluation of Stress in Korean Patients with Diabetes Mellitus Using the Problem Areas in Diabetes-Korea Questionnaire  

UK PubMed Central (United Kingdom)

BackgroundIt is known that diabetes and stress are directly or indirectly related, and that it is important to evaluate stress in patients with diabetes. The relationship between...Full Text Available

2011-04-01

92

Evaluating the Nickel Content in Metal Alloys and the Threshold for Nickel-Induced Allergic Contact Dermatitis  

UK PubMed Central (United Kingdom)

Many patients are currently suffering from nickel (Ni)-induced allergic contact dermatitis (ACD). There have been few Korean studies dealing with the threshold of Ni-induced ACD and quantifying the...Full Text Available

2008-04-01

93

Dietary factors related to body weight in adult Vietnamese in the rural area of Haiphong, Vietnam: the Korean Genome and Epidemiology Study (KoGES)  

UK PubMed Central (United Kingdom)

The objectives of this study were to examine the association between dietary factors and underweight and overweight adult Vietnamese living in the rural areas of Vietnam. A cross-sectional study of...Full Text Available

2010-06-01

94

Development of Korean Academy of Medical Sciences Guideline Rating the Physical Impairment; Kidney, Bladder, Urethra, Male and Female Reproductive Systems (Preliminary Report)  

UK PubMed Central (United Kingdom)

For the evaluation of the kidney impairment, serum creatinine concentrations or glomerular filtration rates are mainly used, and the conditions of solitary or transplanted kidney and chronic dialysis...Full Text Available

2009-05-01

95

CANFLEX-NU fuel licensing status and issues in Korea  

International Nuclear Information System (INIS)

The CANFLEX-NU Fuel Design Report (FDR) for Wolsung 1,2,3,4 was submitted for licensing review in July 1996. The FDR contains sections of fuel rod design, fuel bundle design, nuclear design and thermal-hydraulic design. Each section describes the design bases, design methodology and design evaluation results showing that the design bases are met. The CANFLEX-NU fuel design is not finalized yet in Korean licensing point of view. For example, among others, new Xc-BL correlation is needed to be developed, fuel rod gap reduction effect is to be considered in the Critical Heat Flux, more information for power ramp defect of fuel rod especially in the end-cap weld region is needed in the fuel rod design, and enough data are not available in irradiated conditions in the fuel rod and bundle designs. The specific detailed technical licensing issues and their backgrounds are explained for the CANFLEX-NU FDR in Korea. The Korean nuclear regulation ...

1999-09-26

96

Association of Paraoxonase 1 (PON1) polymorphisms with osteoporotic fracture risk in postmenopausal Korean women  

UK PubMed Central (United Kingdom)

There is increasing evidence of a biochemical link between lipid oxidation and bone metabolism. Paraoxonase 1 (PON1) prevents the oxidation of low-density lipoprotein (LDL) and metabolizes biologically...Full Text Available

2011-02-28

97

Association between hair mineral and age, BMI and nutrient intakes among Korean female adults  

UK PubMed Central (United Kingdom)

This study was performed to investigate the association between hair mineral levels and nutrient intakes, age, and BMI in female adults who visited a woman's clinic located in Seoul. Dietary intakes...Full Text Available

2009-01-01

98

Analysis of the Development of the Nasal Septum according to Age and Gender Using MRI  

UK PubMed Central (United Kingdom)

ObjectivesThis study was designed to evaluate the normal development of the nasal septum in Koreans using sagittal MRI for the valuable clinical information on septal procedures.MethodsTwo...Full Text Available

2008-03-01

99

A study on multi-cultural family wives adapting to Korean cuisine and dietary patterns  

UK PubMed Central (United Kingdom)

With the increase in multi-cultural families, Korea is seeing a rapid increase in immigrated housewives, who are closely related to food culture. However, studies for the diet of multi-cultural families,...Full Text Available

2010-10-01

100

Seismic Design of Korean Next Generation Reactor  

Energy Technology Data Exchange (ETDEWEB)

The objective of the Korean Next Generation Reactor(KNGR) seismic design is to develop a standard design that can cover most of site characteristics in the world with the possible exception of areas of high seismicity. This seismic design was based on the current state-of-the-art as well as the current Nuclear Regulatory guidance. This paper provides a summary on the design parameters used in the KNGR seismic design. In addition, this paper discusses seismic design requirements, selection of generic soil sites, selection of design control motions, and soil-structure interaction(SSI) analyses for the KNGR Nuclear Island(NI) structures. (author). 16 refs., 8 figs.

1999-07-01

101

Development of Tsunami PSA method for Korean NPP site  

International Nuclear Information System (INIS)

A methodology of tsunami PSA was developed in this study. A tsunami PSA consists of tsunami hazard analysis, tsunami fragility analysis and system analysis. In the case of tsunami hazard analysis, evaluation of tsunami return period is major task. For the evaluation of tsunami return period, numerical analysis and empirical method can be applied. The application of this method was applied to a nuclear power plant, Ulchin 56 NPP, which is located in the east coast of Korean peninsula. Through this study, whole tsunami PSA working procedure was established and example calculation was performed for one of real nuclear power plant in Korea

2010-10-01

102

Development of RCM analysis software for Korean nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

A software called KEPCO RCM workstation (KRCM) has been developed to optimize the maintenance strategies of Korean nuclear power plants. The program modules of the KRCM were designed in a manner that combines EPRI methodologies and KEPRI analysis technique. The KRCM is being applied to the three pilot system, chemical and volume control system, main steam system, and compressed air system of Yonggwang Units 1 and 2. In addition, the KRCM can be utilized as a tool to meet a part of the requirements of maintenance rule (MR) imposed by U.S. NRC. 3 refs., 4 figs. (Author)

1998-12-31

103

Review of SCDAP/RELAP5 Code Application to severe accident analysis of CANDU Reactors  

International Nuclear Information System (INIS)

SCDAP/RELAP5 code has been developed in US for best-estimate simulation of light water reactors transients during nuclear accidents. The code models the coupled behaviour of the cooling system, reactor core and fission products release during the accident. It is the result of the coupling between RELAP5, modelling thermal hydraulic, control system, reactor kinetics and the transport of noncondensable gases, and SCDAP code modelling the behaviour of the reactor core during severe accidents. The paper briefly presents the application of SCDAP/RELAP5 code to CANDU severe accident analysis. Also, the paper proposes a summary of the needs for development that could enhance the quality of the severe accidents related predictions in CANDU reactors. (authors)

2009-10-12

104

PSA for CANDU-6 pressurized heavy water reactors: Wolson Units 2,3 and 4 of Korea  

International Nuclear Information System (INIS)

Level 1 and 2 probabilistic safety assessments (PSAs) for both internal and external events are being performed to meet one of the conditions for a construction permit for Wolsong units 2, 3, and 4 in Korea. These units are CANDU-6 Pressurized Heavy Water Reactors (PHWRs), and the study is the first comprehensive level 1 and 2 PSAs for CANDU type plants in the world. The detailed PSA includes and extensive fault tree, event tree analysis, human reliability analysis, and common cause failure analysis. Event trees have been developed for 35 internal initiating event groups. The preliminary results show that the total core damage frequency for Wolsong units 2, 3, and 4 each is similar to that for a typical PWR plant. (author).

1997-06-01

105

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through the CANDU flux ...

1992-01-01

106

Learning from a mouse - how adoption of Disney methods could assist development of CANDU control centres  

Energy Technology Data Exchange (ETDEWEB)

Many organizations are challenged with the tasks of identifying customer needs and expectations for their products, anticipating future product needs, communicating a future product vision to clients, and designing with today's technology to bring a future vision to successful realization. The design evolution of plant control centres is one aspect of CANDU development that faces such challenges. The Disney Corporation is an example of an organization that has been successful in consistently meeting these challenges for over fifty years; and some of the design practices proven in moviemaking, theme park and resort layout, and vacation experience organization may be helpful and effective when applied in other domains. This paper summarizes the findings from an examination of Disney Corporation design practices, and suggests how some practices could be used to simplify and enhance the design of future CANDU control centres. (author)

2005-07-01

107

Development of linear sensitivity matrix method for fast evaluation of CANDU refuelling schemes  

International Nuclear Information System (INIS)

In order to develop a numerical tool for the fast evaluation of CANDU refuelling schemes, a Linear Sensitivity Matrix method (LSM) is developed. It assumes that all the effects caused by various perturbations to the core state are independent to each other and the core response to a perturbation is proportional to its magnitude. In this way, the main core parameters of a refuelling scheme can be derived by simple algebraic operations with the use of pre-calculated sensitivity matrices, without resorting to the complicated and time-consuming 3D core calculation. Verification against the Qinshan CANDU reactor operation history demonstrates that LSM is capable of generating accurate results and running very fast for evaluating a refuelling scheme. (authors)

2009-06-01

108

Canadian fuel development program in 1997/98  

International Nuclear Information System (INIS)

This paper describes the CANDU fuel development activities in Canada during 1997 through 1998. The activities include those of the Fuel Technology Program sponsored by the CANDU Owners Group. The goal of the Fuel Technology Program is to maintain and improve the reliability, economics and safety of CANDU fuel in operating reactors. These activities, therefore, concentrate on the present designs of 28-element and 37-element fuel bundles. The Canadian fuel development activities also include those of the Advanced Fuel and Fuel Cycle Technology Program at AECL. These activities concentrate on the development of advanced fuel designs and advanced fuel cycles, which among other advantages, can reduce the capital and fuelling costs, maintain operating margins in aging reactors, improve natural-uranium utilization, and reduce the amount of spent fuel. (author)

1997-09-21

109

CANDU 6 fuel behaviour in power ramp conditions  

International Nuclear Information System (INIS)

The facilities in the Institute for Nuclear Research at Pitesti allow the testing, handling and examination of nuclear fuel and irradiated materials. The most important facilities are the TRIGA Steady State Research and Material Test Reactor and the Post-Irradiation Examination Laboratory (PIEL). The purpose of this work is to determine by post-irradiation examination, the behavior of CANDU fuel, irradiated in 14 MW TRIGA reactor. The fuel was irradiated in power ramp conditions. The results of post-irradiation examination are: - Visual inspection and photography of the outer appearance of sheath; - Profilometry (diameter, bending, ovality) and length measuring; - Determination of axial and radial distribution of the fusion products activity by gamma scanning and tomography; - Microstructural characterization by metallographic and ceramographic analyzes; - Mechanical properties determination. The data obtained from the post-irradiation examination are used to ...

2009-10-12

110

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-07-01

111

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-06-01

112

Wolsung-1 nuclear power plant. Update report, 1983 June.  

Science.gov (United States)

The Wolsung-1 CANDU 600 MWe plant is now in operation. This paper provides an update on the design, construction and commissioning progress reported at last year's conference. The accomplishments of the past year are highlighted with emphasis on how the s...

1983-01-01

113

Validation of WIMS-AECL reactivity device calculations for CANDU reactor  

Energy Technology Data Exchange (ETDEWEB)

An important component of the overall program to validate WIMS-AECL for use with RFSP in the analysis of CANDU-6 reactors for design and safety analysis calculations is the validation of calculations of incremental cross sections used to represent reactivity devices. A method has been developed for the calculation of the three-dimensional neutron flux distribution in and around CANDU reactor fuel channels and reactivity control devices. The methods is based on one- and two dimensional transport calculations with the WIMS-AECL lattice cell code, SPH homogenization, and three-dimensional flux calculations with finite-difference diffusion theory using the MULTICELL code. Simulations of Wolsung 1 Phase-B commissioning measurements and Point Lepreau restart tests have been performed, as a part of the program to validate WIMS-AECL lattice cell calculations for application to CANDU reactor simulations in RFSP. The incremental ...

1997-06-01

114

New intelligent monitor for CANDU type NPP  

International Nuclear Information System (INIS)

Nuclear energy provides a third of Europe's electricity with nearly no greenhouse-gas emissions. Sustained efforts are now being conducted to harmonize regulations all over Europe through WENRA and to converge on technical nuclear safety practices within the TSO network ETSON (European Technical Safety Organizations Network). In CANDU type NPP the tritiated water occurs by the neutron bombardment of deuterium. The tritiated water vapors imply health hazard (in the critical organs of the body the water presents a 10 day average biological half-life) and the early detection in nuclear plants of tritium emissions is important because the tritiated water vapors have the same characteristics as of atmospheric water vapors. By detecting tritiated vapors, the monitoring system ensures the following objectives: (a) indicates levels of tritium generally due to heavy water leakage, (b) reduces the possibility of health hazard. In order to attain this goal of safety function, ...

2009-10-12

115

Manufacturing Process of UO sub 2 Pellets.  

Science.gov (United States)

To perform the localization project of WOLSUNG reactor fuel, mass-production system of irradiation-stable and sound fuel pellet must be established. The following subjects have been carried out to set up CANDU fuel fabrication process for continuous produ...

1981-01-01

116

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The rods in the bundle may act as a dampener to the vertical flow and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential ...

1997-12-31

117

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The rods in the bundle may act as a dampener to the vertical flow and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential ...

1997-10-04

118

Incident report: spillage of reactor coolant at Wolsung  

Energy Technology Data Exchange (ETDEWEB)

Late last year the Wolsung Candu in Korea suffered an incident which resulted in heavy water being released from the primary system into the containment. With the unit now back at full power, this article examines the causes of the incident and the action which is being taken to prevent it happening again.

1985-05-01

119

Improvement of top shield analysis technology for CANDU 6 reactor.  

Science.gov (United States)

As for Wolsung NPP unit 1, radiation shielding analysis was performed by using neutron diffusion codes, one-dimensional discrete ordinates code ANISN, and analytical methods. But for Wolsung NPP unit 2, 3, and 4, two-dimensional discrete ordinates code DO...

1996-01-01

120

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can inspect each tube for all degradation ...

2006-07-01

121

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can inspect each tube for all degradation ...

2005-11-20

122

Development on the core technologies for tritium removal processes (I).  

Science.gov (United States)

At Wolsung NPP, three more CANDU reactors will be operated soon, and the tritium accumulation in the moderator and coolant systems was estimated to be greatly increased. In order to reduce tritium exposure for nuclear safety at Wolsung, a study was carrie...

1993-01-01

123

Development of CANDU Void Reactivity Uncertainty Evaluation Methodology  

International Nuclear Information System (INIS)

One of inherent characteristics of CANDU reactor is positive void reactivity in contrast to other pressurized light water reactors. During the large break loss of coolant accident, power pulse will be occurred during short time of early phase of accident due to positive void reactivity. However the duration of this power pulse is short, energy due to power pulse would be accumulated in the cladding material and will affect the peak cladding temperature or number of failed fuel elements. Recently, Canadian Nuclear Safety Commission (CNSC) indicated that the amount of void reactivity might be larger than the assumed values in safety analysis and this indication was based on the experimental data from ZED-2 facility. Based on that, the estimation of uncertainties due to the void reactivity during LBLOCA is the most important issue for CANDU safety analysis. In this study, a framework of uncertainty evaluation methodology for ...

2010-10-01

124

Design and construction progress on Gentilly 2, Cordoba, Point Lepreau, and Wolsung projects  

International Nuclear Information System (INIS)

Gentilly 2, Point Lepreau, Cordoba and Wolsung are the first 600 MW CANDU nuclear generating stations to be built. Progress in their construction and in the remaining design work for these stations is discussed. (LL).

1980-06-18

125

Cordoba and Wolsung Projects: A Progress Report.  

Science.gov (United States)

The Cordoba and Wolsung projects mark the entry into the international sales arena of the standardized Canadian 600 MWe CANDU-PHW reactor design. The Cordoba station experienced a setback in the early stages when severe inflation in Argentina led to a ren...

1977-01-01

126

Canada in the world power market  

Energy Technology Data Exchange (ETDEWEB)

Canadian power and industrial projects world-wide are highlighted in this annual feature. A short section on the CANDU Wolsung Reactor in the Republic of Korea mentions that it went critical in November 1982 after taking only 60 months to complete.

1983-01-01

127

Atomic Energy of Canada Limited-Chemical Company Annual Review of Operations, 1980-81.  

Science.gov (United States)

Record production of heavy water was achieved: the plants at Glace Bay and Port Hawkesbury, Nova Scotia, produced a total of 560 megagrams. A shipment of 500 Mg was delivered on time to the Wolsung CANDU reactor in Korea. Energy conservation and waste hea...

1981-01-01

128

A study on the fuel handling control system in CANDU 6 nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The Fuel Handling(F/H) System in existing CANDU 6 nuclear power plants was designed in the early 1960`s, utilizing the technology available at that time. The design for the F/H control system has been proven to be excellent in meeting the functional requirements through more than 20 CANDU units in service or under construction. The significant advance in electrical and electronic engineering area in a few decades motivates the design changes to reduce costs for engineering, construction and operation as well as to improve performance, reliability and safety based on the latest technology. This report outlines the current design of the F/H system, especially for the F/H control system, introduces some topics in research and development projects being carried out by AECL or other institutes, and presents several potential design improvement items for the better CANDU system with brief explanation about implementation. 29 ...

1994-06-01

129

Thermal-hydraulics performance optimization of Candu fuel using Assert subchannel code  

Energy Technology Data Exchange (ETDEWEB)

An optimization of fuel bundle geometry using the subchannel code ASSERT is performed in support of Candu fuel design to enhance the thermohydraulics performance. The new bundle design is based on a reference CANFLEX bundle with changes to the centre and inner-ring element diameters and pitch-circle diameters (PCDs) of various element rings. Different methods of varying the PCDs for reaching the optimized geometry are considered in an attempt to minimize the optimization effort. The optimized geometry in the present analysis is the one that maximizes the dryout power and that has simultaneous CHF (critical heat flux) initiation involving more than one subchannel rings. (authors)

2007-07-01

130

Nuclear design analysis of wolsung-1 CANDU-PHW nuclear generating station  

International Nuclear Information System (INIS)

A combination of computer codes such as LATREP, HWRAXAV and CITATION is utilized in an attempt to analyze the nuclear design characteristics of the CAXDU-PHWR of the Wolsung Unit 1. The major nuclear properties to be computed are the lattice properties of CANDU fuel channel and the core channel power distribution. The computed results are compared with the preliminary safety reports documentation for the Wolsung reactor. The observed discrepancies between our computations and the preliminary safety reports values are discussed in terms of incomplete information on the description of the core configuration in the preliminary safety reports and the different calculation methods. (author).

1978-01-01

131

Input modelling for subchannel analysis of CANFLEX fuel bundle  

Energy Technology Data Exchange (ETDEWEB)

This report describs the input modelling for subchannel analysis of CANFLEX fuel bundle using CASS(Candu thermalhydraulic Analysis by Subchannel approacheS) code which has been developed for subchannel analysis of CANDU fuel channel. CASS code can give the different calculation results according to users' input modelling. Hence, the objective of this report provide the background information of input modelling, the accuracy of input data and gives the confidence of calculation results. (author). 11 refs., 3 figs., 4 tabs.

1998-06-01

132

Canadian nuclear review  

International Nuclear Information System (INIS)

Progress in the construction of Candu reactors at home and abroad is surveyed. Some A.E.C.L. research projects are also mentioned. During 1979, Candu reactors again showed their superior capacity factors, four of them being among the ten most reliable reactors in the world. Progress in construction at Pickering B, Bruce B, Point Lepreau, Gentilly-2, Darlington, Wolsung (Korea), Cordoba (Argentina), and Cernavoda (Romania) is recounted. In 1979, it was unfortunately necessary to replace installed steam generators at Pickering B, Bruce B, Point Lepreau and Gentilly-2. At Wolsung, the reactor was pre-assembled before installation, which is a new technique. (N.D.H.).

1979-01-01

133

A CANDU-6 versus ACR-1000 SDS1 performance comparison during some LOCA scenarios  

International Nuclear Information System (INIS)

According to the Romanian Nuclear Strategy, the third and fourth units of the Cernavoda NPP will be commissioned by 2015. Improvements in operation and safety are expected to be applied for these CANDU-6 based units. On the other side, the need for innovation determined AECL to promote the ACR -1000 - an evolutionary Generation III+ power reactor design and a necessary step towards Generation IV inherently safe nuclear energy systems. CANDU-6 is recognized for having two independent fully capable shutdown systems. ACR-1000 also benefits for this strong safety feature. Two major achievements i.e. using of light water as coolant and using Low Enriched Uranium (LEU) as fuel in a compact heavy water moderated lattice allowed the obtaining of a slightly negative Coolant Void Reactivity (CVR) for the first time in a CANDU-type reactor. The main goal of the paper is to compare the response of SDS1 action during some LOCAs supposed ...

2009-10-12

134

TIG of Reduced Activation Ferrite/Martensitic Steel for the Korean ITER-TBM  

International Nuclear Information System (INIS)

Test Blanket Modules (TBM) will be tested in ITER to verify the capability of tritium breeding and recovery and the extraction of thermal energy suitable for the production of electricity. A Helium Cooled Solid Breeder (HCSB) TBM has been developed in Korea to accomplish these goals. Reduced Activation Ferritic/Martensitic (RAFM) steel has been chosen as the primary candidate structural material for Korean TBM. Due to the complexity of the First wall (FW) and Side wall (SW), it is necessary to develop various joining technologies, such as Hot Isostatic Pressing (HIP), Electron Beam Welding (EBW) and Tungsten Inert Gas (TIG) welding, for the successful fabrication of TBM. In this study, the mechanical properties of TIG welded RAFM steel were investigated. Various mechanical tests of TIG-welded RAFM steel were performed to obtain the optimized TIG welding process for RAFM steel

2010-10-01

135

Seismic qualification method of equipment for nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Safety related equipment installed in Korean Nuclear Power Plants are required to perform a safety function during and after a seismic event. To accomplish this safety function, they must be seismically qualified in accordance with the intent and requirements of the USNRC Reg. Guide 1.100 Rev. 02 and IEEE Std. 344-1987. This paper defines and summarizes acceptable criteria and procedures, based on the Korean experience, for seismic qualification of purchased equipment to be installed in a nuclear power plant. As such the paper is intended to be a concise reference by equipment designers, architectural engineering company and plant owners in uniform implementation of commitments to nuclear regulatory agencies such as the USNRC or Korea Institute of Nuclear Safety (KINS) relating to adequacy of seismic Category 1 equipment. Thus, the paper provides the methodologies which can be used for qualifying equipment for safely related service in Nuclear ...

1995-12-31

136

Regulations on health/functional foods in Korea  

International Nuclear Information System (INIS)

The term 'health/functional food' (HFF) refers to food supplements containing nutrients or other substances (in a concentrated form) that have a nutritional or physiological effect whose purpose is to supplement the normal diet. The Korean Health/Functional Food Act that came into effect in 2004 requires these products to be marketed in measured doses, such as in pills, tablets, capsules, and liquids. HFFs are of two types: generic and product-specific. There are 37 ingredients listed in the act for generic HFFs, and if an HFF contains a new active ingredient that is not included in the generic 37 products, it is considered a product-specific HFF. The standardization, safety, and efficacy of a new active ingredient are reviewed by the Korean Food and Drug Administration in order to receive approval as a product-specific HFF. Conforming with international standards and protecting public health requires constant upgrading of the Health/Functional ...

2006-04-03

137

Green tea consumption, abdominal obesity as related factors of lacunar infarction in Korean women  

British Library Electronic Table of Contents (United Kingdom)

Objectives Our purpose was to evaluate interaction of green tea consumption and abdominal obesity as related factors for lacunar infarction in Korean women. Designs A hospital-based, incident case-control study. Settings The Prevention and Managements of Stroke in Women study. Participants Cases (n=233) of first incident lacunar infarction were enrolled and matched by age to stroke-free hospital controls (n=204). Measurements The data were collected through face-to-face interviews by well trained research assistants to assess demographic, medical, lifestyle, marital status, religions status, green tea consumptions, family history of stroke, smoking status, alcohol consumption, meat and vegetable intake frequency, and past history of hypertension. Biochemical analysis, fasting blood specime...

2011-01-01

138

Experimental study on display-control stereotype and development of human factors guidelines  

Energy Technology Data Exchange (ETDEWEB)

It is very important to develop the design guidelines which can be applicable for Korean operators for the purpose of designing the KSNP more safely. The objective of this project is to provide the standards, guidelines and bases applicable for HF-010 through the within-subject experiment for obtaining Korean operators' population stereotype for direction-of-movement of controls associated with displays on the control panels. Through the survey of researches on display compatibility and the classification of types of displays and controls in the main control room of Uljin units 3 and 4, methods for an experiment on the stereotype were established. Experimental interface prototypes for a total of 108 combinations of display and control types were implemented. Experimental data collection and analysis system was built in association with the interface prototypes. The experiment was performed with participation of 250 students as ...

2003-01-01

139

Evaluation on codes to estimate the number of failed rods using Korean PWR activity data  

International Nuclear Information System (INIS)

The coolant activity analysis to obtain the information about the fuel failure has been studied long before. And several codes have been developed to estimate the number of fuel failures through evaluating volatile and inert fission products release in coolant from the defective fuel. These codes use a fission product diffusion model coupled with a mass balance in the gap and coolant. But each code has a different model to assess fuel failure. In order to develop the model to estimate the number of fuel failures we analysis well-known code's models such as CHIRON, CADE, IODYNE, and CAAP and compare accuracy through Korean PWR activity data

2010-10-01

140

Circulating fluidized bed combustion of Korean anthracite  

Energy Technology Data Exchange (ETDEWEB)

Combustion characteristics of Korean anthracite in a circulating fluidized bed and freeboard were investigated. A test coal was selected with heating value of 4,429kcal/kg and ash content of 38%. Characteristics of combustion, sorbent effect on desulphurisation and emission of SO{sub x} and NO{sub x} were monitored by varying process variables such as feed rate, (Ca+K)/S ratio, and excess air ratio at the given properties of coal. Optimum operating conditions were studied by analysing: axial profiles of temperature, effect of excess air ratio, characteristics of loopseal and bag filter ashes, and emission of toxic gases. 9 refs., 9 figs., 3 tabs.

1994-12-31

141

Jet flow analysis of liquid poison injection in a CANDU reactor using source term  

Energy Technology Data Exchange (ETDEWEB)

For the performance analysis of Canadian deuterium uranium (CANDU) reactor shutdown system number 2 (SDS2), a computational fluid dynamics model of poison jet flow has been developed to estimate the flow field and poison concentration formed inside the CANDU reactor calandria. As the ratio of calandria shell radius over injection nozzle hole diameter is so large (1055), it is impractical to develop a full-size model encompassing the whole calandria shell. In order to reduce the model to a manageable size, a quarter of one-pitch length segment of the shell was modeled using symmetric nature of the jet; and the injected jet was treated as a source term to avoid the modeling difficulty caused by the big difference of the hole sizes. For the analysis of an actual CANDU-6 SDS2 poison injection, the grid structure was determined based on the results of two-dimensional real- and source-jet simulations. The maximum injection ...

2001-01-01

142

The national nuclear material tracking system. A Korea's countermeasure against nuclear terrorism  

International Nuclear Information System (INIS)

Since nuclear terrorism has been identified as a real threat, the Korean government has earnestly developed elementary technologies and sub-systems for establishing an integrated defensive system against nuclear terrorism, which is based on the concept of defense-in-depth. This paper introduces the gist and implications of the studies that have been conducted in building the national nuclear material tracking system for preventing and intercepting the illicit trafficking and transporting of nuclear material in Korea. (orig.)

2011-07-01

143

The market efficiency in the stock markets  

CERN Document Server

We study the temporal evolution of the market efficiency in the stock markets using the complexity, entropy density, standard deviation, autocorrelation function, and probability distribution of the log return for Standard and Poor's 500 (S&P 500), Nikkei stock average index, and Korean composition stock price index (KOSPI). Based on the microscopic spin model, we also find that these statistical quantities in stock markets depend on the market efficiency.

2007-01-01

144

Study on institutionalization of risk-informed performance-based regulation  

International Nuclear Information System (INIS)

In this study, for the institutionalization of risk informed and performance based regulation in Korea, the latest technical movements of overseas countries are examined and reviewed. And the issues that was found when license change petition using risk information was submitted in Korean regulatory body are reviewed. Based on these review, the applicable areas to domestic situation will be found and proposed. This study can contribute to setting up the proper direction for the institutionalization of risk informed and performance based regulation

2007-04-22

145

Study on institutionalization of risk-informed performance-based regulation  

Energy Technology Data Exchange (ETDEWEB)

In this study, for the institutionalization of risk informed and performance based regulation in Korea, the latest technical movements of overseas countries are examined and reviewed. And the issues that was found when license change petition using risk information was submitted in Korean regulatory body are reviewed. Based on these review, the applicable areas to domestic situation will be found and proposed. This study can contribute to setting up the proper direction for the institutionalization of risk informed and performance based regulation.

2003-02-15

146

Low Birth Weight, Very Low Birth Weight Rates and Gestational Age-Specific Birth Weight Distribution of Korean Newborn Infants  

UK PubMed Central (United Kingdom)

To obtain the low birth weight (LBW) rate, the very low birth weight (VLBW) rate, and gestational age (GA)-specific birth weight distribution based on a large population in Korea, we collected and analyzed...Full Text Available

2005-04-01

147

First Outbreak of Multidrug-Resistant Klebsiella pneumoniae Producing both SHV-12-Type Extended-Spectrum ?-Lactamase and DHA-1-Type AmpC ?-Lactamase at a Korean Hospital  

UK PubMed Central (United Kingdom)

PurposeCoexistence of different classes of β-lactamases in a single bacterial isolate may pose diagnostic and therapeutic challenges. We investigated a spread of Klebsiella...Full Text Available

2008-02-29

148

Chorea-ballism associated with nonketotic hyperglycaemia or diabetic ketoacidosis: Characteristics of 25 patients in Korea  

British Library Electronic Table of Contents (United Kingdom)

Chorea-ballism is a rare form of movement disorder complicated by severe hyperglycaemia and in association with a contralateral basal ganglia lesion. We analysed the clinical characteristics of 25 Korean patients with chorea-ballism associated with nonketotic hyperglycaemia or diabetic ketoacidosis. Possible mechanisms of disease are also discussed.

2011-01-01

149

An identity on the $2m$-th power mean value of the generalized Gauss sums  

CERN Document Server

In this paper, using combinatorial and analytic methods, we prove an exact calculating formula on the $2m$-th power mean value of the generalized quadratic Gauss sums for $m\\geq 2$. This solves a conjecture of He and Zhang [`On the $2k$-th power mean value of the generalized quadratic Gauss sums', Bull. Korean Math. Soc. 48 (2011), No.1, 9-15].

2011-01-01

150

A management scheme for reducing pollution at air discharge facility in advance  

Energy Technology Data Exchange (ETDEWEB)

The developed countries are implementing a policy minimizing damage from environmental pollution by reducing discharge in advance as well as the aftermath of a pollutant. The typical example is to use BAT (Best Available Technology). This is to prevent environmental damage by reducing the discharge of pollutants with available technology and to secure environmental margin to enable industrial activities of future generation. Therefore, the feasibility of introducing BAT requirement system was reviewed by considering foreign examples and Korean situation. 38 refs., 8 figs., 69 tabs.

1998-12-01

151

Spent Fuel Transfer to Dry Storage Using Unattended Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

There are 4 CANDU reactors at Wolsung site together with a spent fuel dry storage associated with unit 1. These CANDU reactors, classified as On-Load Reactor (OLR) for Safeguards application, change 16- 24 fuel bundles with fresh fuel in everyday. Especially, the spent fuel bundles are transferred from spent fuel bays to dry storage throughout a year because of the insufficient capacity of spent fuel pond. Safeguards inspectors verify the spent fuel transfer to meet safeguards purposes according to the safeguards criteria by means of inspector's presence during the transfer campaign. For the verification, 60-80 person-days of inspection (PDIs) are needed during approximately 3 months for each unit. In order to reduce the inspection effort and operators' burden, an Unattended Monitoring System (UMS) was designed and developed by the IAEA for the verification of spent fuel bundles transfers from wet storage to dry storage. Based ...

2009-05-15

152

Leak-before-break strategy for CANDU primary piping systems  

Energy Technology Data Exchange (ETDEWEB)

Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other jurisdictions (particularly those in the United States and the Federal Republic of ...

1986-01-01

153

CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25  

International Nuclear Information System (INIS)

The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled using applicable ...

1986-06-09

154

A simplified two step thermal analysis method for Wolsung (CANDU) spent fuel dry storage canister  

Science.gov (United States)

A simplified two step thermal analysis method has been develop to evaluate (1) the mean temperature of the CANDU fuel bundles within a fuel basket in a given spent fuel dry storage canister by HEATING5 code with additional input data and heat transfer correlations in the step-1 analysis and (2) the maximum fuel rod temperature within a CANDU 37-element fuel bundle by MAXROT code developed here for step-2 analysis. In addition, the results of sample analysis is performed to examine the parametric effects of the site-specific ambient conditions on the maximum fuel temperature within a canister are presented. The comparison between the results of step-1 analysis and the mock-up test, in particular, is quite satisfactory. In essence, the two-step thermal analysis method proposed here is a code package that used the HEATING5 and MAXROT codes, respectively, for step-1 and step-2 calculations in series.

1993-03-01

155

A simplified two step thermal analysis method for Wolsung (CANDU) spent fuel dry storage canister  

International Nuclear Information System (INIS)

A simplified two step thermal analysis method has been develop to evaluate (1) the mean temperature of the CANDU fuel bundles within a fuel basket in a given spent fuel dry storage canister by HEATING5 code with additional input data and heat transfer correlations in the step-1 analysis and (2) the maximum fuel rod temperature within a CANDU 37-element fuel bundle by MAXROT code developed here for step-2 analysis. In addition, the results of sample analysis is performed to examine the parametric effects of the site-specific ambient conditions on the maximum fuel temperature within a canister are presented. The comparison between the results of step-1 analysis and the mock-up test, in particular, is quite satisfactory. In essence, the two-step thermal analysis method proposed here is a code package that used the HEATING5 and MAXROT codes, respectively, for step-1 and step-2 calculations in series.

1993-01-01

156

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation on ...

2009-10-15

157

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation on ...

2009-10-01

158

The ageing of CANDU steam generator due to localized corrosion  

International Nuclear Information System (INIS)

The Steam Generator (SG) tubing degradation caused by corrosion and other age-related mechanisms continues to be a significant safety and cost concern for many Nuclear Power Plants (NPP). The understanding of the steam generator ageing mechanisms is the key to effective management of steam generator ageing and consists of the knowledge of steam generator materials and these one properties, stressors and operating conditions, like degradation sites and wear mechanisms. The principal types of corrosion are presented which can occur in CANDU steam generator. There are also presented the operation conditions, the specifications referring to the water chemistry and the construction materials of Steam Generator, the factors that have a great influence on the corrosion behaviour during the whole exploitation period of this equipment. (R.P.)

2001-09-17

159

Support required from Canada in the operation and maintenance of CANDU stations overseas  

International Nuclear Information System (INIS)

The long-term support required from Canada in the operation and maintenance of overseas CANDU nuclear generating stations after commercial operation has commenced is described, with reference entirely to the KANUPP reactor. This includes: technical support to station staff to increase plant reliability and maintainability; assistance with plant improvements; procurement of spares and consumables; and assistance with training programmes. This technical support may be provided by a small number of Canadian staff actually resident at the power station; by short-term visits of Canadian specialists to site and by technical and procurement services provided from Canada. Examples of technical problems experienced are given, showing typical services required from Canada.

160

Optimization of decontamination strategy for CANDU-PHW reactors  

International Nuclear Information System (INIS)

Theoretical models of the decontamination process are developed and combined with an existing model of "6"0Co production in CANDU PHW reactors to predict the effects of decontamination on long term "6"0Co build-up in reactor primary heat transport systems. The effects of decontamination interval, decontamination factor, and post-decontamination corrosion release are calculated. An optimum decontamination strategy for a Pickering G.S. type reactor is developed on the basis of a cost-benefit analysis. This study indicates that the optimum decontamination interval is approximately six years. This optimum interval is relatively insensitive to variations in the costs of personnel exposure, the cost of a decontamination, the decontamination factor, and the post-decontamination corrosion model used. (author).

161

Mode shape and natural frequency identification for seismic analysis from background vibration  

International Nuclear Information System (INIS)

Background vibration in a CANDU plant can be used to determine the dynamic characteristics of major items of equipment, such as calandria, the fuelling machines and the primary heat transport pumps. These dynamic characteristics can then be used to verify the seismic response of the equipment which, at present, is based on theoretical models only. The feasibility and basic theory of this new approach (which uses accelerations measured at several points on a structure and does not require knowledge of the source of excitation) was established in Phase I of the study. This report is based on Phase II in which the methods of analysis developed in Phase I were improved and verified experimentally. A Fast Fourier Transform (FFT) algorithm was incorporated and an interactive curve fitting technique was developed to obtain the dynamic characteristics in the form of natural frequencies, mode shapes and damping ratios. The method is now available for use at a ...

1984-02-06

162

Korea's experience and program on CANDU fuel R and D and fabrication  

International Nuclear Information System (INIS)

In Korea, a manufacturing process for the fabrication of CANDU 37-element fuel bundles was successfully developed between 1981 and 1986. At Korea Atomic Energy Research Institute (KAERI), more than 20,000 fuel bundles were produced up to May 1992, for use in Wolsung-1 power reactor. At the time of the conference, about 15,000 of these fuel bundles had been irradiated in Wolsung-1, and almost all of them had performed well. From 1995, the commercial fuel production program will be transferred to Korea Nuclear Fuel Company, which is building a plant with a capacity of 400 tons of uranium per year. So-called CANFLEX fuel, more appropriate to advanced fuel cycles, is being developed jointly by AECL and KAERI. The paper includes a listing of the current status of the Republic of Korea's nuclear power plants, with planning projections up to the year 2006. 2 tabs.

1992-10-04

163

Fuel cost analysis of CANDU-PHWR Wolsung Nuclear Power Plant unit 1  

International Nuclear Information System (INIS)

Being based on the Segal method, calculation was carried out for the natural uranium nuclear fuel cost with Zircaloy-4 cladding having design parameters of Wolsung Nuclear Power Plant, CANDU-PHWR (Unit 1), currently under construction in Korea aiming at its completion in 1982. An attempt was also made for the sensitivity analysis of each fuel component; i.e., depreciation of fuel manufacturing plant caused by its life time, its load factor, production scale expansion of plant facilities, variations of construction and operating costs of fuel manufacturing plant, fluctuation of interest rates, extent of uranium ore price increases and effect of learning factor. (author).

1977-01-01

164

Development of technology on the material surveillance of CANDU pressure tubes  

International Nuclear Information System (INIS)

Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test equipments and test (DHCV, hydriding, grip and tensile specimen etc). 23 figs, 6 tabs, 59 refs. (Author).

1997-05-21

165

Design principles for CANDU control centres in response to evolving utility business needs  

Energy Technology Data Exchange (ETDEWEB)

Nuclear generation operators are facing a challenging business environment at the beginning of the new millennium. Evolving changes in business context, competitive commercial pressures, and changes in technology have dictated recurring evaluation of operational practices and the adequacy of supporting tools, and the pursuit of opportunities for operational improvement. A key area of utility operations that has been impacted by these changes is the nuclear plant control centre. Changes to workspace layout, equipment provisions, staffing, and work organization are examples of some of the adjustments being introduced to improve operational and safety effectiveness. This paper discusses some of the key factors influencing these changes and identifies additional design principles for CANDU control centres that will enable new control centre designs and retrofits of existing control centres to remain relevant and responsive to utility needs. (author)

2002-07-01

166

Demonstration drop test and design enhancement of the CANDU spent fuel storage basket in dry storage facility  

British Library Electronic Table of Contents (United Kingdom)

A dry interim storage facility has been constructed at the Wolsung power plant in Korea. This dry storage facility has seven separated modules. There are 40 long slender cylinders in one module. In one cylinder, ten baskets where sixty CANDU spent fuel bundles are loaded are stacked and stored. For this dry storage facility, analyses and tests for hypothetical accident conditions that might occur while moving and storing the baskets into a cylinder were performed. In a demonstration test, one of test basket models did not satisfy one of the safety-related requirements. Thus, the revised basket designs were generated using a structural evaluation based on finite element analyses and specimen tests. Among these revised designs, one design was chosen as a final revised basket design. The fina...

2011-01-01

167

Steam generator design improvements for the candu wolsung nuclear power plant  

International Nuclear Information System (INIS)

Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.

1978-01-01

168

Modification of fuel bundles and associated optimization of fuel handling equipment  

Energy Technology Data Exchange (ETDEWEB)

This is a continuation of research that started in July 2007 at the Deep River Science Academy. The research was related to the effects of endplate thickness and misalignment of fuel bundles in the fuel channel on pressure losses of reactor coolant. Based on this research, a new approach to refueling of the CANDU reactor has been developed. It greatly simplifies fuel handling equipment and increases its reliability. It also reduces required staffing, as well as operating and maintenance costs associated with fuel handling. (author)

2008-07-01

169

Incident report: spillage of reactor coolant at Wolsung  

International Nuclear Information System (INIS)

Late last year the Wolsung Candu in Korea suffered an incident which resulted in heavy water being released from the primary system into the containment. With the unit now back at full power, this article examines the causes of the incident and the action which is being taken to prevent it happening again. (author).

1985-01-01

170

Improvement of top shield analysis technology for CANDU 6 reactor  

Energy Technology Data Exchange (ETDEWEB)

As for Wolsung NPP unit 1, radiation shielding analysis was performed by using neutron diffusion codes, one-dimensional discrete ordinates code ANISN, and analytical methods. But for Wolsung NPP unit 2, 3, and 4, two-dimensional discrete ordinates code DOT substituted for neutron diffusion codes. In other words, the method of analysis and computer codes used for radiation shielding of CANDU 6 type reactor have been improved. Recently Monte Carlo MCNP code has been widely utilized in the field of radiation physics and other radiation related areas because it can describe an object sophisticately by use of three-dimensional modelling and can adopt continuous energy cross-section library. Nowadays Monte Carlo method has been reported to be competitive to discrete ordinate method in the field of radiation shielding and the former has been known to be superior to the latter for complex geometry problem. However, Monte Carlo method had not been used for radiation ...

1996-07-01

171

Getting to grips with remote handling and robotics  

International Nuclear Information System (INIS)

A report on the Canadian Nuclear Society Conference on robotics and remote handling in the nuclear industry, September 1984. Remote handling in reactor operations, particularly in the Candu reactors is discussed, and the costs and benefits of use of remote handling equipment are considered. Steam generator inspection and repair is an area in which practical application of robotic technology has made a major advance. (U.K.).

172

Fuel management optimization in CANDU reactors cooled with light water; Optimisation de la gestion du combustible dans les reacteurs CANDU refroidis a l'eau lege  

Energy Technology Data Exchange (ETDEWEB)

This research has two main goals. First, we wanted to introduce optimization tools in the diffusion code DONJON, mostly for fuel management. The second objective is more practical. The optimization capabilities are applied to the fuel management problem for different CANDU reactors at refueling equilibrium state. Two kinds of approaches are considered and implemented in this study to solve optimization problems in the code DONJON. The first methods are based on gradients and on the quasi-linear mathematical programming. The method initially developed in the code OPTEX is implemented as a reference approach for the gradient based methods. However, this approach has a major drawback. Indeed, the starting point has to be a feasible point. Then, several approaches have been developed to be more general and not limited by the initial point choice. Among the different methods we developed, two were found to be very efficient: the multi-step method and the mixte method. ...

2006-07-01

173

Efficiency of preliminary transmutation of actinides before ultimate storage  

International Nuclear Information System (INIS)

The concept of preliminary transmutation of minor actinides before placement to the long-term storage is considered. The purpose of such preliminary transmutation before ultimate storage is to incinerate a part of actinides and to transform another part into new actinides providing low level of radiotoxicity accumulated in the storage. Modes of transmutation in reactors of PWR, PHWR (CANDU), and Superfenix types are compared. Among power reactors, heavy-water PHWR type reactor is most acceptable for preliminary transmutation. (author)

2003-04-20

174

An experimental plan for improvement of failed fuel monitoring system in CANDU reactor  

Energy Technology Data Exchange (ETDEWEB)

An experimental plan for improving the problems of failed fuel location system in Wolsung Unit-2 reactors was established. It is not possible to make an experiment on the failed fuel monitoring nuclides in the cold laboratories because they have very short half life. Therefore, the experiments can be only carried out at the existing monitoring system under reactor operation. For that reason, an experimental plan was drawn up for installing the radiation detection system on reactor site.

2003-10-01

175

Pressure drop variation as a function of axial and radial power distribution in CANDU fuel channel with standard and CANFLEX 43 bundles  

International Nuclear Information System (INIS)

CANDU 600 nuclear reactors are usually fuelled with STANDARD (STD), 37 rods fuel bundles. Natural uranium (NU) dioxide (UO_2), is used as fuel composition. A new fuel bundle geometry called CANFLEX (CFX) with 43 rods is proposed and some new fuel composition are considered. Flexibility is the key word for the attempt to use some different fuel geometries and compositions for CANDU 600 nuclear reactors as well as for innovative ACR-700/1000 nuclear reactors. The fuel bundle considered in this paper is CFX-RU-0.90 that encodes the CANFLEX geometry, recycled dioxide uranium (RU) with 0.90% enrichment. The goal of this proposal is ambitious: a higher average discharge burn-up up to 14000 MWd/tU and, for the same amount of generated electric power, reduction in nuclear fuel fabrication, reduction of spent nuclear fuel radioactive waste and reduction of refueling operational work by using fewer bundles. An improved sub-channel approach for ...

2007-11-22

176

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

Energy Technology Data Exchange (ETDEWEB)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. ...

1995-07-01

177

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

International Nuclear Information System (INIS)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements ...

1346-01-01

178

Wall thinning trend analyses for secondary side piping of Korean NPPs  

International Nuclear Information System (INIS)

Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the site application feasibility for secondary side piping management. The site ...

2003-08-17

179

The automatic programming for safety-critical software in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

We defined the Korean unique safety-critical software development methodology by modifying Dr. Harel`s statechart-based on formal methods in order to digitalized the reactor protection system. It is suggested software requirement specification guideline to specify design specification which is basis for requirement specification and automatic programming by the caused by shutdown parameter logic of the steam generator water level for Wolsung 2/3/4 unit SDS no.1 and simulated it by binding the Graphic User Interface (GUI). We generated the K and R C code automatically by utilizing the Statemate MAGNUM Sharpshooter/C code generator. Auto-generated K and R C code is machine independent code and has high productivity, quality and provability. The following are the summaries of major research and development. - Set up the Korean unique safety-critical software development methodology - Developed software requirement specification guidelines - ...

1998-06-01

180

The application of irradiation techniques for food preservation and processing improvement  

Energy Technology Data Exchange (ETDEWEB)

This project has intended to develop alternative techniques to be used in food industry for food processing and utilization by safe irradiation methods. For improvement of rheology and processing in corn starch by irradiation, the production of modified starch with low viscosity as well as with excellent viscosity stability became feasible by the control of gamma irradiation dose levels and the amount of added inorganic peroxides to starch. Also, this project was developed the improvement methods of hygienic quality and long-term storage of dried red pepper by gamma irradiation. And, in Korean medicinal plants, 10 kGy gamma irradiation was effective for improving sanitary quality and increasing extraction yield of major components. For the sanitization of health and convenience foods, gamma irradiation was more effective than ozone treatment in decontamination of microorganisms, with minimal effect on the physicochemical properties analysed. In evaluation of ...

1997-09-01

181

Systematic Failure in a Stem Cell Fraud Case by a Poor Quality Culture  

International Nuclear Information System (INIS)

In the years 2004 and 2005, Korea became a prospective nation noteworthy in the world through the epochal development of genetic engineering in our country. Obstinate or incurable diseases were expected to be healed in a few years by a Korean geneticist. So many worldwide patients of obstinate or incurable diseases took notice of the research outcomes and organized an aid association to collect supporting funds. World renowned journals such as 'Nature' and 'Science' published Dr. Hwang's theses. A long and distant way remedy to obstinate diseases seemed to be closer at hand so early. However, a stem cell fraud case emerged throughout the world in late 2005, the pride of the Korean people was destroyed. With this as a momentum, voices of self reflection by scientific circles were raised. The purpose of this study is not in finding the truth of the stem cell research but to propose an effective management and control measures for the future in ...

2006-05-25

182

Improving PSA quality of KSNP PSA model  

Energy Technology Data Exchange (ETDEWEB)

In the RIR (Risk-informed Regulation), PSA (Probabilistic Safety Assessment) plays a major role because it provides overall risk insights for the regulatory body and utility. Therefore, the scope, the level of details and the technical adequacy of PSA, i.e. the quality of PSA is to be ensured for the successful RIR. To improve the quality of Korean PSA, we evaluate the quality of the KSNP (Korean Standard Nuclear Power Plant) internal full-power PSA model based on the 'ASME PRA Standard' and the 'NEI PRA Peer Review Process Guidance.' As a working group, PSA experts of the regulatory body and industry also participated in the evaluation process. It is finally judged that the overall quality of the KSNP PSA is between the ASME Standard Capability Category I and II. We also derive some items to be improved for upgrading the quality of the PSA up to the ASME Standard Capability Category II. In this paper, we ...

2004-07-01

183

An analysis of PZR and related system design features for KNGR  

Energy Technology Data Exchange (ETDEWEB)

The development of KNGR (Korean Next Generation Reactor) is now in progress. KAERI is developing KNGR which is a advanced active PWR (pressurized water reactor) and 1350 MW electric capacities and is by based on UCN(Ulchin) 3 and 4 nuclear power plant which is a Korean standard PWR. In this report, the PZR (pressurizer) and Related System Design Features for KNGR which include PZR volume, PPCS (pressurizer safety valve)were analyzed. First, the Design Parameters between KNGR compared to UCH 3 and 4 were compared, and second, advanced design features of KNGR compared to UCN 3 and 4 were analyzed. After the present analysis, it has been concluded that the safety margins for the PZR level and pressure of KNGR were more increased by the larger PZR volume than those of UCN 3 and 4, for PZR minimum water level at reactor/turbine trip and PZR maximum pressure at LOCV(loss of condenser vacuum) of KNGR were higher and lower, respectively than those of ...

1995-12-01

184

Structural integrity evaluation of fuel test loop submerged in water subjected to postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

The structural integrity of the Fuel Test Loop(FTL) in a Korean experimental reactor is evaluated when the FTL, submerged in a water environment, is subjected to a postulated pipe rupture. The analyses are performed under static and dynamic conditions, imposing the thrust force history at each postulated pipe rupture section. Through analysis the following results are found: 1) A double ended guillotine can not be expected based on the toughness of the material, 2) the structural integrity of the chimney surrounding the FTL would not impede the structural integrity by the pipe whip. All analyses are performed by finite element methods.

2000-02-01

185

Glocalisation or globalisation? Travelling discourses of child poverty policy in South Korea  

British Library Electronic Table of Contents (United Kingdom)

This article examines the interplay between globalising and localising forces occurring in a child welfare reform project in South Korea. Focusing especially on care and education services for children and families provided by the Korean 'Dream Start' programme, which provides comprehensive health, parental involvement and welfare services to low-income children and their families, I discuss its involvement in the process of 'glocalisation'. Drawing on Foucaultian ideas, I conducted a critical discourse analysis of the policy documents of Dream Start. The article concludes by discussing local resistance to the creation of a cosmopolitan child and the dual qualities of inclusion/exclusion inscribed in the Dream Start project.

2011-01-01

186

Sensitivity Study for CFD Analysis on Debris Transport to ECCS Sump for CANDU Type Plant in Korea  

International Nuclear Information System (INIS)

Once containment recirculation pumps are activated and emergency core cooling (ECC) flow is supplied from the recirculation sump during loss of coolant accident (LOCA), various insulations and coatings on a pipe, equipments and structures damaged by LOCA break jet as well as additional debris sources are transported to recirculation sump screen by the break flow and containment spray flow drainage. This debris may result in loss of net pressure suction head (NPSH) of the recirculation pumps, and have a threat to long term cooling and containment heat removal capacity. In this case, flow patterns of containment pool are important to confirm behaviors of debris transport for predicting various flow paths to the recirculation sump screen. In this paper, models using commercial computational fluid dynamics (CFD) software CFX are developed for containment pool simulation during recirculation mode. The specific plant used for this analysis is CANDU type plant, in Korea

2010-10-01

187

Parametric effects of ambient conditions on thermal safety of Wolsung (CANDU) unit 1 spent fuel dry storage canister  

Energy Technology Data Exchange (ETDEWEB)

To resolve the central thermal safety issue for spent fuel dry storage concrete canister design or Wolsung (CANDU) nuclear power plant unit 1, a thermal analysis method has been developed for the complicated geometry of rod bundles and the multi-dimensional and multi-mode heat transfer phenomena. The canister geometry is simplified and combined heat transfer by conduction, convection, and radiation is considered through effective heat transfer coefficients. Mean temperature distributions of the fuel bundles within the fuel basket are obtained by solving the heat transfer problem using an existing computer code HEATING5. The measured steady state temperature distribution within a mock-up of a storage basket is compared to the calculated result. Steady state and/or transient fuel temperature distributions have been calculated for various ambient conditions at the canister exterior surface.

1992-07-01

188

Parametric effects of ambient conditions on thermal safety of Wolsung (CANDU) unit 1 spent fuel dry storage canister  

International Nuclear Information System (INIS)

To resolve the central thermal safety issue for spent fuel dry storage concrete canister design or Wolsung (CANDU) nuclear power plant unit 1, a thermal analysis method has been developed for the complicated geometry of rod bundles and the multi-dimensional and multi-mode heat transfer phenomena. The canister geometry is simplified and combined heat transfer by conduction, convection, and radiation is considered through effective heat transfer coefficients. Mean temperature distributions of the fuel bundles within the fuel basket are obtained by solving the heat transfer problem using an existing computer code HEATING5. The measured steady state temperature distribution within a mock-up of a storage basket is compared to the calculated result. Steady state and/or transient fuel temperature distributions have been calculated for various ambient conditions at the canister exterior surface.

1992-10-31

189

Drop Test of the Candu Spent Fuel Storage Basket in MACSTOR/KN-400  

International Nuclear Information System (INIS)

The MACSTOR/KN-400 of Wolsung power plant in Korea is a dry interim storage facilities. There are 400 long slender cylinders in MACSTOR/KN-400. In one cylinder, ten baskets where Candu spent fuels are loaded are stacked and stored. For this MACSTOR/KN-400 facilities, analyses and tests for the hypothetical accident conditions that might happen during moving and storing baskets into a cylinder were performed. The hypothetical accident conditions to be considered are two cases. One is the case of basket dropping onto the bottom plate of a cylinder. The other is the case of basket dropping onto the other basket top plate stored in the cylinder. For the drop analyses, the case of hanging cylinder and the case of cylinder on the unyielding target surface were considered. Based on the dropping analysis, testing condition was determined as the latter case that is for the cylinder on the target surface. In a basket, 60 dummy fuel bundles are loaded which have the same ...

2009-06-01

190

Different aspects of safety in Nuclear Fuel Plant at Pitesti, Romania  

International Nuclear Information System (INIS)

Nuclear Fuel Plant (FCN) is a facility that produces fuel bundles of CANDU-6 type for the CANDU nuclear power plant. Only natural and depleted uranium in bulk and itemized form are present as nuclear materials in this facility. Uranium and wastes from the plant are handled, processed, treated and stored throughout the entire facility. The nuclear materials with natural and depleted uranium are entirely under nuclear safeguards. The amount of uranium present in the plant in different forms and activities together with zircaloy, beryllium and other hazardous substances, wastes, explosive materials at high temperatures, etc. lead to special measures undertaken by Nuclear Safety Department (DNS) to ensure nuclear safety. Different aspects of safety are continuously monitored in the plant: operational safety, industrial safety, radiological safety, labour safety, informational safety. The emergency preparedness and response, physical protection and ...

2009-10-12

191

Control room monitoring of process conditions and identification of improvements to Darlington monitoring displays  

Energy Technology Data Exchange (ETDEWEB)

In supervising CANDU plant operation, Operations staff must routinely monitor plant status using information from several information systems. One key source of plant status information are the CRT displays at console workstations and panel locations. At Darlington, as at most CANDU plants, Operations staff have adopted a reference set of displays for use in monitoring during Full Power Steady State conditions. The display set employed was chosen from the available suite of displays, and operational experience has demonstrated that the current displays could be improved. For Outages, no reference display set has been defined, and for Upset conditions, the current Transient display set does not provide the information needed by operations staff, and consequently is not used. This paper describes the basis for and findings from a COG project [1] undertaken in 1997 to characterize monitoring practice and develop improvements to control room ...

1999-07-01

192

An analysis of thinning status for CANDU feeder pipes  

Energy Technology Data Exchange (ETDEWEB)

The degradation status of outlet feeders in Wolsung unit 1 is analyzed using feeder thickness measurement data during overhaul period in 2000. DBs related to feeder thinning are made for parameters affecting dissolution rate and parameters affecting mass transfer rate. The initial thickness of feeder in Wolsung unit 1 is analyzed using initial thickness data of Wolsung unit 2, 3 and 4 as there are no initial thickness data of Wolsung unit 1. The initial thickness is varied as feeder diameter and bending degree, and CANDU feeders can be divided as 3 types for 2.5'' feeders and 3 types for 2'' feeders. The average initial thickness value for each type is defined as the initial thickness value of the type for Wolsung unit 1 feeders. Thinning rate is evaluated as the value dividing difference between initial thickness and minimum measured thickness by operation time. It is found that the distribution of thinning rate for flow ...

2000-10-01

193

The regional control of the canadian energy production; Le contraste provincial de la production energetique canadienne  

Energy Technology Data Exchange (ETDEWEB)

This document provides information and presents data on the energy situation in many regions of Canada. The first part deals with the petroleum and the bitumen shales of Alberta (reserves, exploitation and production, environmental impacts), the second part discusses with the hydroelectricity choice of Quebec and the 2004 crisis. The nuclear situation of Ontario is presented in the third part (nuclear park, programs, uranium reserves, research and development on Candu reactors), while the fourth part deals with the renewable energies (wind power and biomass). The canadian situation facing the Kyoto protocol is discussed in the last part. (A.L.B.)

2004-12-01

194

Some studies on physics parameters of Wolsung unit no. 1  

International Nuclear Information System (INIS)

Nuclear physics parameters of the Wolsung CANDU-PHW reactor are computed by use of the PHWCELL computer code that is an improved version of LATREP. The PHWCELL code mainly computes cell parameters of heavy water moderated reactors, and modeling scheme of heavy water reactor cell calculations has been developed with the PHWCELL computer code. The reactor operating conditions considered in the study are cold zero power (CZP) and hot full power (HFP) with equilibrium poison. The cell parameters are also computed as a function of fuel burnup and the numerical results are compared with the results in PSR of the Wolsung unit and in the previous study. (author).

1980-01-01

195

Safety design guide for pipe rupture protection for CANDU 9  

Energy Technology Data Exchange (ETDEWEB)

This safety design guide for pipe rupture protection identifies high-energy systems in which pipe ruptures must be postulated to occur, as well as systems that must be protected from the dynamic effects of such ruptures. Dynamic effects considered in this SDG consist of pipe whip (including missiles generated by pipe ruptures, if any) and jet impingement, Requirements for protection against the dynamic effects of a postulated pipe rupture and method of protection of essential structures, systems and components are specified for these effects. The change status for the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 2 tabs., 5 refs. (Author) .new.

1996-03-01

196

Proceedings of the third international conference on containment design and operation. v.1  

International Nuclear Information System (INIS)

The second international conference on containment design and operation included sessions on the following topics: performance and regulatory requirements; radionuclide behaviour; severe accident design and analysis; operation, maintenance, leaking and aging of containment systems; thermal hydraulic behaviour of containment systems; hydrogen mixing and mitigation; design methods and concepts; code validation; structural analysis and response tests; passive safety systems; aerosol behaviour; containment reliability, integrity, and risk assessment; hydrogen deflagration and detonation. Due prominence was given to CANDU and other PHWR reactors. The individual papers have been abstracted separately.

1994-10-19

197

Nondestructive Detection Techniques of Garter Springs from CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.

2004-04-15

198

NPD Canada's first nuclear power station  

Energy Technology Data Exchange (ETDEWEB)

This talk reviews the history of the Canadian nuclear-electric program highlighting Canada's first nuclear power station, the Nuclear Power Demonstration or NPD. NPD was commissioned and delivered electricity to Canadian consumers for the first time on june 4, 1962. The Canadian nuclear-electric program is based on the CANDU-PHW (Canadian Deuterium Uranium - Pressurized Heavy Water) concept which was conceived between 1955 and 1958 at the Chalk River Nuclear Laboratory (CRNL) of AECL, located a few miles from Deep River. This talk covers the history of the Canadian nuclear-electric activities dating back to 1939.

2002-07-01

199

CRC handbook of nuclear reactors calculations. Vol. II  

International Nuclear Information System (INIS)

This handbook breaks down the complex field of nuclear reactor calculations into major steps. Each step presents a detailed analysis of the problems to be solved, the parameters involved, and the elaborate computer programs developed to perform the calculations. This book bridges the gap between nuclear reactor theory and the implementation of that theory, including the problems to be encountered and the level of confidence that should be given to the methods described. Volume II: Monte Carlo Calculations for Nuclear Reactors. In-Core Management of Four Reactor Types. In-Core Management in CANDU-PHW Reactors. Reactor Dynamics. The Theory of Neutron Leakage in Reactor Lattices. Index.

200

Response strategy and hierarchy of Wolsong 2, 3, and 4 nuclear power plant abnormal operating manuals  

International Nuclear Information System (INIS)

Wolsong 2, 3, and 4 are CANDU 6 pressurized heavy water nuclear power plants, each with a gross electrical output of 715 MW(e). The plants were constructed in the Republic of Korea during the 1990s. The three Wolsong units are based on the previous CANDU Wolsong Unit 1, declared in service in 1983. All four units are presently in commercial service. The Wolsong abnormal operating manuals were developed in a cooperative effort between Atomic Energy of Canada Limited, Korea Power Engineering Company staff, and Korea Electric Power Corporation. The role of Atomic Energy of Canada Limited in performing risk assessment studies and supporting CANDU stations for the preparation of emergency operating procedures has greatly benefited the Wolsong abnormal operating manual program. Korea Electric Power Corporation provided training and supervision, Korea Power Engineering Company Inc. prepared the documentation, and Korea Electric ...

201

Mitigating aging in CANDU plants  

Energy Technology Data Exchange (ETDEWEB)

Aging degradation is a phenomenon we all experience throughout life, both on a personal basis and in business. Many industries have been successful in postponing the inevitable impact on their related systems and components through programs to maintain long-term reliability, maintainability and safety. However, this has not always been the case for nuclear power. While all power plants are experiencing the world trend of increasing operating costs with age, few (if any) have been able to fully define the parameters that solve the aging equation, particularly in relation to major components. Inspection and preventive maintenance have not been effective in predicting life-limiting degradation and failure. In CANDU nuclear plants, utilities are taking a comprehensive approach in dealing with the aging problem. Programs have been established to identify the current condition and degradation mechanisms of critical components, the failure of which would impact negatively ...

1995-07-01

202

Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis  

International Nuclear Information System (INIS)

As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points and by -10% for the corner of the calandria ...

2009-07-01

203

Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests  

Energy Technology Data Exchange (ETDEWEB)

The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy ...

1998-10-01

204

Analysis of log rate noise in Ontario's CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. It was found that ...

2007-07-01

205

Studies on application of radiation and radioisotopes -The application of irradiation techniques for food preservation and process improvement-  

Energy Technology Data Exchange (ETDEWEB)

The project was designed to solve the infra structural problem required for commercialization of food irradiation. In improvement of physical properties of corn starch, gamma irradiation was effective for increasing glucose productivity and for substituting traditional modified starches (acid modified starch, oxidized starch). In immobilization of microorganisms, the mass production method of natural red pigment was developed by using immobilized mold pellets. In Korean medicinal plants, 10 kGy gamma irradiation was effective for improving sanitary quality and increasing extraction yield. In evaluation of wholesomeness, gamma irradiated red ginseng could be safe on the genotoxic point of view. And also, six items of irradiated foods approved for human consumption from Korea ministry of health and welfare in May 19, 1995. 30 figs, 20 tabs, 54 refs. (Author).

1995-07-01

206

Review of Regulatory Quality Assurance Requirements for the Operation of Nuclear R and D Facilities  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation, including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently, nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/ contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. In this paper, the context of amended Atomic Energy laws were reviewed to confirm quality assurance measures and identify additional QA activities, if any, that is required by the amendment

2005-10-27

207

Preliminary seismic safety evaluation of the Uljin nuclear power plant site regarding the offshore Uljin earthquake on the 29 May 2004 as an empirical Green's function  

International Nuclear Information System (INIS)

The moderate earthquake of magnitude 5.2 was occurred at the offshore Uljin on the 29 May 2004. The magnitude of the event is the largest one which is equal to that of the Sokrisan earthquake on the 16 September 1978 since the beginning of the instrumental recording by the Korean Metrological Administration (KMA) in 1978. The magnitude of the event was large enough to be felt in a wide area of the southern Korea. It did not affect the safety of the Uljin nuclear power plant (NPP) site which is about 80 km away from the epicenter. In this article, we estimate source parameters of the event and evaluate preliminary seismic safety of the Uljin NPP site regarding the event as an empirical Green's function (EGF)

2010-10-01

208

Electricity demand for South Korean residential sector  

Energy Technology Data Exchange (ETDEWEB)

This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment.

2009-12-15

209

Electricity demand for South Korean residential sector  

Energy Technology Data Exchange (ETDEWEB)

This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment. (author)

2009-12-15

210

Electricity demand for South Korean residential sector  

British Library Electronic Table of Contents (United Kingdom)

This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement...

2009-01-01

211

Effects of Scutellaria baicalensis on chronic cerebral hypoperfusion-induced memory impairments and chronic lipopolysaccharide infusion-induced memory impairments  

British Library Electronic Table of Contents (United Kingdom)

Ethnopharmacological relevance: Extracts of the roots of Scutellaria baicalensis Georgi (Labiatae) have been widely used to relieve fever related to bacterial infection and inflammatory diseases in traditional Korean medicine and have been reported to be effective in brain diseases. These experiments were conducted to examine the effects of oral administration of Scutellaria baicalensis extracts on the rescue of memory impairments induced by chronic cerebral hypoperfusion or chronic lipopolysaccharide (LPS) infusion. In addition, the underlying mechanisms of these effects were investigated. Materials and methods: In the first experiment, chronic cerebral hypoperfusion was induced in male Wister rats by bilateral common carotid artery occlusion (BCCAo). Daily administration of Scutellaria b...

2011-01-01

212

Bulk trade and maritime transport costs: the evolution of global markets  

Energy Technology Data Exchange (ETDEWEB)

Since the 1950s a transport revolution has occurred comparable to events in the late nineteenth century when sailing ships were replaced by steam vessels. Freight rates for bulk products have decreased 65-70% due to improved maritime technology, and formerly separate markets for bulk products have been unified globally. It is suggested that the low freight rates since the early 1980s will level out in future. Price peaks caused by political and military crises like the Korean war, the Suez crisis, OPEC I and OPEC II also seem to be of diminishing importance over time. The world market has become much less sensitive to external shocks due to alternative sources of supply and alternative transport routes. Examples are given from the coal, grain and iron ore international market. 62 refs., 24 figs., 4 tabs.

1996-03-01

213

The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...

2011-04-15

214

Recent Korean R&D in Satellite Communications  

Science.gov (United States)

The R&D in satellite communications in Korea has been driven mainly by KCC (Korea Communications Commission) but in a small scale compared to Korea space development program organized by MEST (Ministry of Education, Science and Technology). Public and civilian satcom sector R&D has been led mainly by ETRI with small/medium companies contrary to rare investment in private sector while military sector R&D has been orchestrated by ADD with defense industry. By the COMS (Communication, Ocean and Meteorological Satellite) experimental Ka-band payload, Korea pursues a space qualification of own technology for national infrastructure evolution as well as industrialization of space R&D results. Once COMS launched and space qualified in 2009, subsequent application experiments and new technology R&D like UHDTV will entail service and industry promotion. The payload technology is expected for the next Korean commercial satellites or for new OBP ...

2009-01-01

215

Load-following operation of PWR plants  

Energy Technology Data Exchange (ETDEWEB)

The load-following operation of nuclear power plants will become inevitable due to the increased nuclear share in the total electricity generation. As a groundwork for the load-following capability of the Korean next generation PWRs, the state-of-the-art has been reviewed. The core control principles and methods are the main subject in this review as well as the impact of load-following operations on the fuel performance and on the mechanical integrity of components. To begin with, it was described what the load-following operation is and in what view point the technology should be reviewed. Afterwards the load-following method, performance and problems in domestic 900 MWe class PWRs were discussed, and domestic R and D works were summarized. Foreign technologies were also reviewed. They include Mode G and Mode X of Foratom, D and L bank method of KWU, the method using PSCEA of ABB-CE, and MSHIM of Westinghouse. The load-following related special features of ...

1993-12-01

216

Cobalt and organics removal effect using fiber filter/reverse osmosis combination process for LLRW from korean PWR NPP  

Energy Technology Data Exchange (ETDEWEB)

Evaporation system for liquid radioactive waste process has been used in Korean PWR nuclear power plants. The system is the most desirable process for decontamination factor (DF) theoretically. However, during the operation of the system, various problems have been arising such as scaling, carry over, etc. Because these problems make DF low, advanced technologies for liquid radwaste process have been world widely developed instead of keeping evaporation system. The main goal of new technologies is ALARA, ease of operation, cost effectiveness and minimization of environmental effect. Korea Electric Power Corporation is currently developing a combined treatment process for liquid radwaste using Micro-filter, Ultra-filter, Reverse Osmosis (RO) membrane, etc for the purpose of partly enhancement of evaporator and of having an alternative liquid radwaste process system for new reactors. As a part of the above project, the feasibility study using the Rolled Fiber-Filter ...

2001-07-01

217

A lateral cephalometric study of the size of tongue and intermaxillary space in Korean  

International Nuclear Information System (INIS)

A study was performed to investigate the size of tongue area and intermaxillary space area, and compare the sexual differences between normal Korean children and adults by introducing planimetric and linear analysis of the lateral cephalograms. The cephalograms were composed of 41 child male aged 10.8, 40 child female aged 10.5, 38 adult male aged 21.3 , and 40 adult female aged 20.8 respectively. In order to study and measure the intermaxillary space area, the following were selected, as reference items: occlusal plane, anterior intermaxillary space height, posterior intermaxillary space height, length of intermaxillary space. Among those reference items anterior intermaxillary space height and posterior intermaxillary space height were perpendicular to the maxillary plane. An index, (Anterior intermaxillary space height + posterior intermaxillary space height )/2 Length of intermaxillary space, was introduced for the calculation of intermaxillary space area. ...

1977-11-01

218

A lateral cephalometric study of pharyngeal cavity in Korean adults  

International Nuclear Information System (INIS)

A study was performed to investigate the size of pharyngeal cavity and sexual differences between Korean adult mal e and female by introducing linear analysis of the lateral cephalogram. The radiograms were composed of 46 adult male aged 24.64 and 52 adult female aged 22.74 respectively. In order to study and measure the pharyngeal area, the following skeletal landmarks were selected: S,N,A,Ptm, B,H,H', M ,S-N, FH and CV, and the angle CV-FH was measured to provide a factor for correction of error resulting from improper he ad positioning of subjects, especially in the relative positions of A and H, while radiography. All points to be measured were projected at right angles to the Frankfort plane. For the purpose of measuring the anteroposterior dimensions of pharyngeal cavity the distances were measured in A-Ptm, A-S, S-Ptm and CV-H, and vertical measurements were made in SN-A, SN-PNS, SN-H' and M-H. The obtained results were as follows: 1. The pharyngeal cavity ...

1976-11-01

219

A lateral cephalometric study of craniofacial variation in Korean child twins  

International Nuclear Information System (INIS)

A study was performed to investigate the degree of similarities and differences in components of craniofacial complex between Korean twins and normal children by lateral cephalometric analysis. Dimensions of S-N, S-Ba, N-Ba, Go-Me, Ar-Go and Ar-Me were plotted against linear measurement and angles of N-S-Ba and gonial against angular measurement in twins and control groups. The lateral cephalograms of twin were composed of 88 twins aged from 7 to 12:44 males aged 10.65 and 44 females aged 9. 55, while those of 50 normalities were composed of 25 male and 25 female aged 10.9 respectively. In order to analyze growth proportion and sexual differences, twins were divided into 3 groups according to two year age intervals and the author compared male with female in 3 groups. For the purpose of observing similarities and differences in twins and normalities by sex, total twins were compared with normalities. The obtained results were as follows: 1. There was no difference ...

1974-11-01

220

Reconsidering the site requirements for NPP on Olt River  

International Nuclear Information System (INIS)

Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation water cooling circuit system was ...

2009-10-12

221

Evaluation of SCC susceptibility of alloy 800 under CANDU SG secondary-side conditions  

Energy Technology Data Exchange (ETDEWEB)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified with the respect of stress corrosion cracking susceptibility. The effects of lead contamination on the ...

2006-07-01

222

Evaluation of SCC susceptibility of alloy 800 under CANDU SG secondary-side conditions  

International Nuclear Information System (INIS)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified with the respect of stress corrosion cracking susceptibility. The effects of lead contamination on the ...

2006-11-26

223

Thermalhydraulic Characteristics for Wolsung-1 after retubing  

International Nuclear Information System (INIS)

The ROP margin in a CANDU reactor is decreasing over time due to the Primary Heat-Transport System (PHTS) aging effect. Adjustment of the ROP trip setpoint is required to maintain a high trip-probability and ROP trip effectiveness. Especially, for Wolsong-1, which is scheduled to change the old pressure tubes in 2009, the trend of ROPT after the retubing should be reevaluated. Before setting a ROPT, the main thermal characteristics including Critical Channel Power (CCP) should be calculated by the NUCIRC code. In this paper, the thermalhydraulic evaluation for Wolsung-1 was conducted with the updated Wolsung-1 PHTS data. Specifically, for the case of 0 EFPY (Effective Full Power Year) and 11 EFPY after the retubing, the distribution of the channel flow rate, channel exit quality, critical channel power, and critical power ratio (CPR) of the Wolsong-1 aged plant are calculated

2009-05-01

224

The Status of Korea-IAEA Enhanced Cooperation on the Spent Fuel Transfer to Dry Storage in CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

Based on the enhanced cooperation between Republic of Korea (ROK) and International Atomic Energy Agency (IAEA), IAEA installed new safeguards equipment (Unattended Monitoring System, UMS) at Wolsung unit 2 on January, 2005. The UMS was utilized in parallel with traditional human surveillance during the transfer campaign of Wolsung unit 2 (7 March - 22 July). Installation of UMS at all Wolsung units will be decided on the basis of the result of this test. The transfer campaign with UMS at Wolsung units 2 and 4 was started from September 1, 2006 at the same time. Implementation of UMS to the transfer campaign in Wolsung site will be considerably reduced the IAEA's inspection effort and burden of operator.

2006-07-01

225

The Status of Korea-IAEA Enhanced Cooperation on the Spent Fuel Transfer to Dry Storage in CANDU Reactors  

International Nuclear Information System (INIS)

Based on the enhanced cooperation between Republic of Korea (ROK) and International Atomic Energy Agency (IAEA), IAEA installed new safeguards equipment (Unattended Monitoring System, UMS) at Wolsung unit 2 on January, 2005. The UMS was utilized in parallel with traditional human surveillance during the transfer campaign of Wolsung unit 2 (7 March - 22 July). Installation of UMS at all Wolsung units will be decided on the basis of the result of this test. The transfer campaign with UMS at Wolsung units 2 and 4 was started from September 1, 2006 at the same time. Implementation of UMS to the transfer campaign in Wolsung site will be considerably reduced the IAEA's inspection effort and burden of operator.

2006-11-02

226

Technical Standards for Wolsong Unit 1 Nuclear Power Plant  

International Nuclear Information System (INIS)

More than twenty years after commencing commercial operation in 1983, Wolsong Unit 1(W1- NPP), the first CANDU Pressurized Heavy Water Reactor (PHWR) in Korea, has been undergoing refurbishment. Safety analyses were required to evaluate the safety of W1-NPP because significant amount of equipment has been refurbished. To evaluate the effectiveness of W1-NPP after these upgrades, new safety analyses were performed using the same technical standards of Wolsong Units 2, 3, 4 (W234-NPP) for Design Basis Accidents (DBA). The refurbished W1- NPP is expected to be licensed for full power operation based on the verified safety analysis results that are obtained by using the upgraded computer codes and newly adopted technical standards of W234-NPP

2010-10-01

227

Severe accident analysis for Wolsung nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

Severe accident analysis has been performed for the Wolsung nuclear power= plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks (LOAH) which is caused by loss of off-site power, diesel generators, and DC power. ISAAC (Integrated Severe Accident Analysis Code) computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanisms of calandria vessel and containment. In addition, some insights for accident management program (AMP) are also given. (Author) 5 refs., 1 tab., 12 figs.

1997-05-01

228

Severe accident analysis for Wolsung nuclear power  

Energy Technology Data Exchange (ETDEWEB)

Severe accident analysis has been performed for the Wolsung nuclear power plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks (LOAH) which is caused by loss of off-site power, diesel generators, and DC power, ISAAC(Integrated Severe Accident Analysis Code) computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanisms of calandria vessel and containment. In addition, some insights for accident management program (AMP) are also given.

1997-05-01

229

Real-time neutron radiography for visualisation of interfacial geometry and phase distribution in two-phase flow  

International Nuclear Information System (INIS)

Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).

1989-10-01

230

Overview of nuclear power plant equipment qualification issues and practices  

International Nuclear Information System (INIS)

This report presents a view of and commentary on the current status of equipment qualification (EQ) in nuclear industries of the major western nations. The introductory chapters discuss the concepts of EQ, the elements of EQ process and highlight some of the key issues in EQ. A brief review of industry practices and some of the prevalent industrial standards is presented, followed by an overview of current regulatory positions in the USA, France, Germany and Sweden. A summary and commentary on the latest research findings on issues relating to accident simulation, to aging simulation and some special topics related to EQ, has been contributed by Franklin Research Centre of Philadelphia. The last part of the report deals with equipment qualification in Canada and gives recommendations on EQ for new plants as well as currently operational CANDU nuclear power plants.

1984-05-15

231

Hydrogen absorption behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

The deuterium uptake behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1 was analyzed in terms of longitudinal location, operation time, and coolant temperature. The results were compared with those obtained from Canadian CANDU reactors. The amount of deuterium uptake was higher at the outlet part than at the inlet part and was also higher when subjected to a longer operation time and a higher coolant temperature. The hydrogen uptake of Zr-2.5Nb in a hydrogen gas atmosphere was dependent on the microstructure of the alloy. The aged Zr-2.5Nb consisting of {alpha}-Zr and {beta}-Zr phases. The hydrogen in the alloy decreased the rate of oxidation. This could be explained in terms of the cathodic controlled reaction of Zr-2.5Nb oxidation. (author)

1998-08-01

232

Development and validation of a CATHENA fuel channel model for a post-blowdown analysis of the high temperature thermal-chemical experiment CS28-1  

British Library Electronic Table of Contents (United Kingdom)

To form a licensing basis for a new methodology for a fuel channel safety analysis code for CANDU-6 nuclear reactor, a CATHENA model for a post-blowdown fuel channel analysis has been developed, and tested for a high temperature thermal-chemical experiment CS28-1 [Lei, Q.M., 1993. Post-test analysis of the 28-element high-temperature thermal-chemical experiment CS28-1. In: 4th International Conference on Simulation Methods in Nuclear Engineering, Montreal, PQ, 1993]. Pursuant to the objective of this investigation, the current study has focused on understanding the involved phenomena, their interrelations, and how to maintain a good accuracy of the temperature and H2 generation rate prediction without losing the important physics of the involved phenomena. The transient simulation results ...

2009-01-01

233

Design on SDS2 on-line poison concentration monitoring in CANDU  

Energy Technology Data Exchange (ETDEWEB)

At the reference plant (Wolsung unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsung unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low. 8 refs., 1 fig. (author).

1996-10-01

234

A task-based usage strategy for control centre wall displays  

Energy Technology Data Exchange (ETDEWEB)

This paper summarizes the findings from an exploratory definition of a usage strategy for multiple control centre wall displays in CANDU nuclear power plants. Wall displays are defined as large sized, vertically oriented display surfaces that may be positioned in various locations about a control room to support user information needs. The paper begins by discussing the need for a usage strategy for all control room information resources, and then reviews the history in wall display implementation and usage in nuclear power plant control rooms. The balance of the paper discusses the approach used in characterization and review of control room task information needs and definition of a wall display usage strategy. The paper concludes by outlining some of the possible impacts on future control room design and operations that the introduction of wall displays may imply. (author)

2005-07-01

235

Visual inspection technology of the narrow and small confined area for monitoring feederpipe support of pressure tube in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post-Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And ultrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughly because of narrow and confined accessibility, that is , an inspection space between the pressure tube channels is less than 100 mm and pipes in feederpipe support area ...

1999-12-01

236

Validation of the Canadian atmospheric dispersion model for small exclusion area boundaries  

International Nuclear Information System (INIS)

AECL is undertaking the validation of ADDAM, an atmospheric dispersion and dose code based on the Canadian Standards Association model CSA N288.2. The key component of the validation program involves the comparison of air concentrations predicted by the model with measured values. Measurements are available from field studies at two Canadian reactor sites and from a wind tunnel study of the CANDU site at Wol song, Korea. The measurements were obtained close enough to the release points to test the model for exclusion area boundaries as small as 500 m. Model predictions were higher than the observations almost 75 percent of the time and the magnitude of the over predictions was typically much larger than the magnitude of the under predictions. The effect of the topography at the Wol song site was limited to small changes in plume trajectory due to channeling in valleys and a small reduction in the lateral spread of the plume. The terrain did not substantially ...

1999-11-04

237

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

Energy Technology Data Exchange (ETDEWEB)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface probes. Two-dimensional voltage diagrams showing ...

1996-01-01

238

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

International Nuclear Information System (INIS)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface probes. Two-dimensional voltage diagrams showing ...

1992-01-01

239

On the development of the METAR family of inspection tools  

Energy Technology Data Exchange (ETDEWEB)

Since 1998, Hydro Quebec Research Centre (IREQ), in collaboration with Gentilly-2, has been working on the development of inspection devices for the feeder tubes of CANDU power plants. The first tool to come out of this work was the Metar bracelet, now used throughout the CANDU utilities, consisting of 14 ultrasonic probes held in place in a rigid bracelet to measure the thickness of the pipes and moved around manually along the pipe. Following the success of the Metar, a motorized version, i.e. the Crawler, has been developed to inspect beyond the operator arm's reach to access hard to reach place or further down the pipes in the reactor. This new system has been tested at 3 different stations and will be commercially available soon. Finally, the same technology was used to develop a motorized 2-axis crack detection device to answer new concerns about the feeder. Other configurations, depending on the demands from the industry, could ...

2003-07-01

240

Internal dose from tritium at Wolsung nuclear power plant  

International Nuclear Information System (INIS)

Tritium is produced in large quantities at heavy water nuclear power reactors via the neutron activation reaction "2H(n,#gamma#)"3H. At Wolsung nuclear power plant which has a CANDU reactor, the tritium concentrations in coolant and in moderator systems are 1.5 Ci/Kg-D_2O and 35 Ci/kg-D_2O, respectively, after 12 years of operation. The airborne tritium concentration in main access area is normally less than 5 MPCa except short-term peaks. The average tritium concentrations in main access controlled areas are normally less than 100 MPCa. Tritium is mainly present in the air of workplace of CANDU reactors as a tritiated water vapour. Airborne tritiated water vapour enters the workers body via inhalation and absorption through skin and can result in a significant dose. The occupational doses from tritium at Wolsung NPP have been maintained below 1 man-Sv per year so far. The tritium contribution to the total plant man-Sv changes between 30 ...

1995-02-01

241

Estimation of source term release during SGTR sequences at Wolsong plants  

International Nuclear Information System (INIS)

Source term release characteristics are analyzed for the severe SGTR (Steam Generator Tube Rupture) sequences beyond the design basis accidents in Wolsong 2/3/4 plants which are of CANDU6 type reactor. In PWRs, SGTR sequences have long been recognized to be important and are distinctly different from the non-bypass sequences since there is a direct fission product release path from the primary system to the environment bypassing the containment gas volume. Meanwhile, a SGTR in a CANDU reactor is analyzed not to provide a complete and direct path into the environment for the source term resulting from a severe accident. This is because the majority of the fission product released arises from heatup and interactions of the disassembled fuel channel segments and debris in the calandria tank rather than from fuel heatup in the fuel channel. These fission products are released from the calandria tank into the containment atmosphere through the four ...

1998-10-21

242

Development of video probe system for inspection of feeder pipe support in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post- Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And untrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughlv because of narrow and confined accessibility, that is, an inspection space between the pressure tube channels is less than 100mm and pipes in feederpipe support area are congested. And also, workers involved in inspecting feederpipe support area ...

2000-07-01

243

Delayed Hydride Cracking Mechanism in Zirconium Alloys and Technical Requirements for In-Service Evaluation of Zr-2.5Nb Tubes with Flaws  

International Nuclear Information System (INIS)

In association with periodic inspection of CANDU nuclear power plant components, Canadian Standards Association issued CSA N285.8 in 2005 as technical requirements for in-service evaluation of zirconium alloy pressure tubes in CANDU reactors. This first version, CSA N285.8 involves procedures for, firstly, the evaluation of pressure tube flaws, secondly, the evaluation of pressure tube to calandria tube contact and, thirdly, the assessment of a reactor core, and material properties and derived quantities. The evaluation of pressure tube flaws includes delayed hydride cracking evaluation the procedures of which are stipulated based on the existing delayed hydride cracking models. For example, the evaluation of flaw-tip hydride precipitation during reactor cooldown involves a procedure to calculate the equilibrium hydrogen equivalent concentration in solution at the flaw tip, Htipas follows: Htip=Hfexp[- (VH delta no.)/RT], where Hf is the total ...

2007-05-10

244

Characteristics of U-tube assembly design for CANDU 6 type steam generators  

Energy Technology Data Exchange (ETDEWEB)

Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator tubes can potentially be subject to adverse environmental conditions which will cause damages to U-tube ...

1996-06-01

245

The KSNPP risk-effect analysis of the digital safety-critical systems  

Energy Technology Data Exchange (ETDEWEB)

The study was performed for evaluating the risk effect of digital systems on the total plant. Based on risk monitor, a fault tree model for the Korean Standard Nuclear Power Plants (KSNPP), we integrate the fault-tree models for Digital Plant Protection System (DPPS) and Digital Engineered SaFety Actuation System (DESFAS) which are the most important safety-critical I and C systems in the KSNPP. In this study, however, three important factors (the probabilities of manual actuation failure, the software failure probability, and the watchdog timer fault coverage) are treated as the variables of the sensitivity study because quantification methodologies for these factors are not developed yet. Not only the unavailability of digital safety-critical system itself, but also the risk effect of digital systems on the total plant should be assessed to prove the safety of digital systems. The result of sensitivity study shows that the Anticipated-Transient-Without-Scram ...

2004-02-01

246

Carbon pools and flux in the forests of Korea  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the estimated the rate of carbon accumulation in the woody biomass and total carbon storage in the forests including trees, soil and litter in Korea. The relevant data come from the Statistical Yearbook of Forestry and major results of the studies on forest biomass in Korea. Most of the forests, which has been denuded or degraded during the 2nd World War and the Korean War, were recovered through ``Reforestation Project(1973-1987)`` and natural regeneration. So, now they are mostly young secondary forests and grow rapidly. Total carbon removal by forests is estimated at 8.1 million tonnes of carbon(MtC) and the carbon emission by commercial harvesting at 0.9 MtC. therefore, the forests in Korea play an essential role as a net carbon sink. The annul net carbon removal is 7.2 MtC and accounts for about 11.0% of total carbon emissions in energy sector of Korea. The carbon storage in the forests is 589.9 MtC, 22.4% of that stored in trees, 64.1% in ...

1998-04-01

247

Assimilation and Segregation of Imperial Subjects: "Educating" the Colonised during the 1910-1945 Japanese Colonial Rule of Korea  

Science.gov (United States)

This study looks at how education policies in colonial Korea changed over time in order to accommodate the needs of the colonial authorities during the period of Japanese colonial rule in Korea (1910-1945). The colonial experience can be divided into four different periods according to the four Educational Ordinances issued in 1911, 1922, 1938, and 1943 by the colonial government with each period corresponding to a historic event or context. The constitutive relevance of colonial discourse for an understanding of education can be found in the gradual transformation of the education sector in Korea under colonial rule. It is evident that Japanese colonial policy was inherently contradictory in principle and in practice. On the one hand it sought the assimilation of the Koreans, while on the other it maintained its discriminatory and exploitative practices. Such contradiction was obvious within the colonial education system. As the principal instrument of ...

2010-12-01

248

A study on the relevance and influence of the existing regulation and risk informed/performance based regulation  

Energy Technology Data Exchange (ETDEWEB)

The goal of this study is to estimate the relevance and Influence of the Existing Regulation and the RI-PBR to the institutionalization of the regulatory system. This study reviews the current regulatory system and the status of the RI-PBR implementation of the US NRC and Korea based upon SECY Papers, Risk Informed Regulation Implementation Plan (RIRIP) of the US NRC and other domestic studies. In order to investigate the perceptions, knowledge level, ground for the regulatory change, a survey was performed to Korean nuclear utilities, researchers and regulators on the perception on the RIR. The questionnaire was composed of 50 questions regarding personal details on work experience, level of education and specific field of work ; level of knowledge on the risk informed performance based regulation (RI-PBR); the perception of the current regulation, the effectiveness, level of procedure, flexibility, dependency on the regulator and personal view, and the perception ...

2003-02-15

249

A study on the planning to promote the advanced nuclear technology development project  

Energy Technology Data Exchange (ETDEWEB)

Korea has participated in GIF from early stage, and played an important role in GIF as an original signatory of the GIF Charter. Korea has dispatched two representatives of GIF Policy Group and Expert Group respectively. Korea submitted 10 concepts of Gen IV for Gen IV technology roadmap. Korea's KALIMER and SMART concepts have stood higher in technological evaluation. 7 Korean experts were dispatched for Gen IV technology roadmap (4 from institution, 3 from industry and 1 form academia). Furthermore, USA's NTD (Near term Deployment) will be expanded to I-NTD (International NTD). This study suggested that Korea should propose APR-1400 as I-NTD concept for I-NTD discussion in GIF. Finally, Korea and USA jointly decided to fund 2 million dollars respectively for 2001 I-ERI program and selected 6 projects for the program, which are composed of 4 for LWR area and 2 for I and C area. 27 refs., 6 figs., 11 tabs. (Author)

2002-03-01

250

A Demonstration of Level-2 Risk Uncertainty Decreasing Efforts for a Phenomenological Accident Progression Prediction  

International Nuclear Information System (INIS)

An uncertainty decrease is an very important issue for enhancing risk-informed (RI) activities worldwide. Especially, a relatively large uncertainty in a level-2 (L2) PSA risk compared with level-1 internal PSA risk has been a bottleneck problem in the RI application to the extent of a severe accident management. According to the ASME PRA standard in which sources of an uncertainty to capture a category-II RI (= Option 2) capability are listed, an uncertainty analysis which identifies the key sources of an uncertainty and includes sensitivity studies for dominant contributors to LERF (Large Early Release Frequency) needs to be provided. To solve these problems, USNRC have developed the 'SPAR-LERF' model related to the L2 RI application and 'L2 uncertainty assessment and improvement' work is being taken as a main PSA2 topic of the SARNET (Severe Accident Research Network of Excellence) program in Europe by OECD/NEA. Domestically, a mid/long-term R and D is being started this year to ...

2007-05-10

251

International nuclear liability as an element of nuclear safety; Internationales Atomhaftungsrecht als Element der nuklearen Sicherheit  

Energy Technology Data Exchange (ETDEWEB)

The main objective of nuclear liability law is the compensation of victims of a possible nuclear incident. However, an adequate nuclear liability law is just as important for nuclear industry, in particular the supply industry - including suppliers of know-how and consultants. Without such a law, the liability risk would be incalculable and industry would not be ready to supply to nuclear installations or nuclear activities. This applies especially to programmes which aim at improving nuclear safety in Eastern Europe. Key elements are the exclusive concentration of liability onto the operator of a nuclear installation (channelling of liability) and the channelling of lawsuits onto one single competent court in one single country. There are recent examples: The negotiations on the management of nuclear waste, including submarines, in Northern Russia and the negotiations within the framework of the East Asian project of the Korean Peninsula Energy Development ...

2002-09-01

252

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves based on ...

1997-11-16

253

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves based on ...

1997-07-01

254

Theoretical and scaling factors methods to calculate the radioactivity in operational waste streams from Unit 1 at Cernavoda NPP  

International Nuclear Information System (INIS)

The main goal of this paper is to present a methodology for calculating the radioactivity in the moderator and heat transport systems of Cernavoda NPP Unit 1, with the intention to improve the knowledge on the radionuclides inventories in the operational waste streams, and to aid the licensing process of new near surface repository. In the present paper we describe our methodology for estimating H-3 and C-14 production rates in the heavy-water moderator and heat transport systems using the capacity factors from 1997 to 2007 years. The radioactivity of the difficult-to-measure nuclides is predicted by scaling method using measured concentration in reference CANDU 6 reactor Gentilly-2. The difficult-to-measure radionuclides of primary interest in this study were those with long half-lives which have a significant role for post-closure safety assessment. The equation used to scale fission products (parents and daughters) is based on the equilibrium solution of the ...

2009-05-27

255

The Experience of Cooperation with IAEA new approach for Spent Fuel Transfer Campaign at CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

It was agreed that both of the Republic Of Korea (ROK) and the International Atomic Energy Agency (IAEA) cooperate with the new approach using the Unattended Monitoring Systems (UMS), the mailbox declaration and the short notice inspections, which can decrease the agency inspection efforts and operator' s burden. As a result of the positive cooperation of ROK for applying new approach, the IAEA could accomplish a successful implementation of new safeguards approach during last transfer campaigns at Wolsung site. As of the end of Feb. 2007, the IAEA installed the UMS at Wolsung units 2, 3 and 4. The transfer campaigns at Wolsung units 2 and 4 are performing from April, 2007. The IAEA will install the UMS at Wolsung unit 1 by the end of 2007. Then agency will inspect all of transfer campaign at Wolsung units by using new approach with UMS, mailbox declaration and SNI. It is based on the SSAC full cooperation with IAEA to meet agency safeguards goals.

2007-07-01

256

The Experience of Cooperation with IAEA new approach for Spent Fuel Transfer Campaign at CANDU Reactors  

International Nuclear Information System (INIS)

It was agreed that both of the Republic Of Korea (ROK) and the International Atomic Energy Agency (IAEA) cooperate with the new approach using the Unattended Monitoring Systems (UMS), the mailbox declaration and the short notice inspections, which can decrease the agency inspection efforts and operator' s burden. As a result of the positive cooperation of ROK for applying new approach, the IAEA could accomplish a successful implementation of new safeguards approach during last transfer campaigns at Wolsung site. As of the end of Feb. 2007, the IAEA installed the UMS at Wolsung units 2, 3 and 4. The transfer campaigns at Wolsung units 2 and 4 are performing from April, 2007. The IAEA will install the UMS at Wolsung unit 1 by the end of 2007. Then agency will inspect all of transfer campaign at Wolsung units by using new approach with UMS, mailbox declaration and SNI. It is based on the SSAC full cooperation with IAEA to meet agency safeguards goals.

2007-05-10

257

Spectral dependence of ultrasonic attenuation for hydrided Zr-2.5%Nb Alloy  

International Nuclear Information System (INIS)

The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructive testing technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is determined by the energy losses in ...

2009-10-12

258

Nuclear power plant support activities in reactors chemistry at CNEA  

International Nuclear Information System (INIS)

Argentina has two operating PHWR nuclear power plants. Atucha I NPP is a pressure vessel type heavy water reactor of 360 MW e with 25 years of operation and Embalse NPP is a pressure tube type CANDU-600 reactor of 640 MW e. Atucha II, a third plant of 600 MW e of the pressure vessel type similar to Atucha I, is being constructed. NASA (Nucleoelectrica Argentina S.A.) currently operates both nuclear power plants. The National Atomic Energy Commission (Comision Nacional de Energia Atomica - CNEA) provides operational support to the plants, including research and development assistance, and actual technical services and maintenance work in different areas. The Chemistry Department, formerly the Reactor Chemistry Department has carried out project and support activities to the plants during the past 20 years. The aim of this work is to describe the present organization and the activities in reactor chemistry of the Chemistry Department. In particular, the projects to ...

1999-10-15

259

New developments in dry spent fuel storage  

International Nuclear Information System (INIS)

As shown in various new examples, HABOG facility (Netherlands), CERNAVODA (Candu - Romania), KOZLODUY (WWER - Bulgaria), CHERNOBYL ( RMBK - Ukraine), MAYAK (Spent Fuel from submarine and Icebreakers - Russia), recent studies allow to confirm the flexibility and performances of the CASCAD system proposed by SGN, both in safety and operability, for the dry storage of main kinds of spent fuel. The main features are: A multiple containment barrier system: as required by international regulation, 2 independent barriers are provided (tight canister and storage pit); Passive cooling, while the Fuel Assemblies are stored in an inert atmosphere and under conditions of temperature preventing from degradation of rod cladding; Sub-criticality controlled by adequate arrangements in any conditions; Safe facility meeting ICPR 60 Requirements as well as all applicable regulations (including severe weather conditions and earthquake); Safe handling operations; Retrievability of the ...

2001-06-18

260

Licensing experiences of safety critical software systems in nuclear applications a case study  

Energy Technology Data Exchange (ETDEWEB)

This paper summarizes results of reviews on the safety, critical software performed during the licensing process for the new Wolsung units. Each of these CANDU-type nuclear power plants has two micro-computerized shutdown systems. The SDS No. 1 program is graphically programmed in such a manner that its development process does not essentially differ from the design process of the conventional analog counterpart. This approach is understandable even to a reviewer in the regulatory agency without additional training in software engineering. The confidence in the reliability of this system is strengthened by the reverse verification and increased by extensive testing such as the reliability test. Concerning SDS No. 2, the development process is significantly influenced by the {open_quotes}software cost reduction project{close_quotes} of the U.S. naval research laboratory, and is, as a whole, clear and well structured except for the modules related to the operation of ...

1997-12-01

261

Licensing experiences of safety critical software systems in nuclear applications a case study  

International Nuclear Information System (INIS)

This paper summarizes results of reviews on the safety, critical software performed during the licensing process for the new Wolsung units. Each of these CANDU-type nuclear power plants has two micro-computerized shutdown systems. The SDS No. 1 program is graphically programmed in such a manner that its development process does not essentially differ from the design process of the conventional analog counterpart. This approach is understandable even to a reviewer in the regulatory agency without additional training in software engineering. The confidence in the reliability of this system is strengthened by the reverse verification and increased by extensive testing such as the reliability test. Concerning SDS No. 2, the development process is significantly influenced by the software cost reduction project of the U.S. naval research laboratory, and is, as a whole, clear and well structured except for the modules related to the operation of the computer itself. These ...

1997-06-01

262

Irradiation characteristics examination technology development of irradiated nuclear material and high burn-up fuels  

Energy Technology Data Exchange (ETDEWEB)

The research and development for the first year of the project are performed through specialization of researchers, information from aborad and international cooperation, securement of advanced nuclear technology, development and installation of test equipment, application of external man-power, establishment of advanced test techniques, and certified test method. 1. Absolute efficiency measurement examination technology development of gamma scanning system 2. Sample preparation technology development of SEM and EPMA for micro-structural observation and chemical composition analysis 3. Irradiated high burn-up nuclear fuel transportation and test for PWR 4. Development of hot cell examination techniques and equipment 5. Acquirement of KOLAS system. In addition to the project, the following activities are carried out as follows; - PIE of Hanaro fuel(KH99H-001) - PIE of U-Mo advanced nuclear fuel irradiated at Hanaro - PIE of Hi-MET advanced nuclear fuel irradiated at Hanaro - PIE of ...

2002-12-01

263

Investigation of natural circulation two-phase flow behaviour in header manifold using CFD code  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional (3-D), multiphase, computational fluid dynamic (CFD) code FLUENT is used to simulated two-phase flow behaviour in a CANDU header manifold under low (natural circulation) flow conditions. This behaviour was previously inferred from experimental data. The CFD simulations reported here are being used to support these inferences and to obtain a better understanding of phase distribution in the header manifold. The simulations seem to show that the vapor-water mixture models in the FLUENT code do not capture properly phase separation in the header and proper phase branching at the header-feeder connections that have been observed in experiments at low flows. The simulations using discrete-phase model in FLUENT, which tracks the pathlines of the individual vapor bubbles in the water continuum phase, show interesting, complicated and, in some cases, unexpected bubble trajectories from the point of injection of the bubbles at a feeder connection to ...

2006-07-01

264

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a cylindrical 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the cylindrical rod bundles. A new flow regime is observed and designated large amplitude stratified wavy (LASW) flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occuring in the bundle. The rods in the bundle may act as a dampener to the vertical flow component and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential direction. The effect of ...

2000-08-01

265

Historical development of alloy 800  

International Nuclear Information System (INIS)

Alloy 800 was developed in 1949 by The International Nickel Company, Inc. The basic composition, nominally 32wt.%Ni, 20.5wt.%Cr and 46wt.%Fe, was designed to provide a stable, fully austenitic structure and to impart high strength combined with resistance to oxidation, carburization and corrosion in a wide variety of aggressive industrial environments at elevated temperatures. In the short span of twenty-five years, alloy 800 has earned a unique position in the family of heat- and corrosion-resistant materials. Established uses include a wide range of applications in the industrial heating field, in the petro-chemical industry, in domestic appliances and in food processing equipment. The good performance of alloy 800 in these applications has led to its use as boiler tube material both in fossil-fired plants and in HTGR and PWR nuclear power systems. Recently, it was specified for a PHW CANDU reactor and it is now being considered as heat exchanger tube material ...

266

Experimental investigation on the fretting wear of alloy 800 in room remperature water  

Energy Technology Data Exchange (ETDEWEB)

Fretting wear test in room temperature water was performed to evaluate the wear coefficient of CANDU (CANadian Deuterium Uranium) steam generator (SG) tube material (Alloy 800) against 410 type martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel 690. Test conditions are 10{approx}30N of normal load, 200{approx}450mm of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between ...

2002-05-01

267

Experimental investigation on the fretting wear of alloy 800 in room remperature water  

International Nuclear Information System (INIS)

Fretting wear test in room temperature water was performed to evaluate the wear coefficient of CANDU (CANadian Deuterium Uranium) steam generator (SG) tube material (Alloy 800) against 410 type martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel 690. Test conditions are 10#approx#30N of normal load, 200#approx#450mm of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between ...

2002-05-01

268

Evaluation of ROP Margin Effectiveness by REFORM Region  

Energy Technology Data Exchange (ETDEWEB)

In CANDU reactors, the Regional Overpower Protection Trip (ROPT) system protects the reactor against overpowers in the reactor fuel, whether due to localized peaking within the core or a general increase in core power levels. Due to Primary Heat-Transport System (PHTS) aging the ROP trip setpoint is decreasing over time. Reductions in ROP trip setpoints are required to maintain the required trip-probability and ROP trip effectiveness, and results in a decrease of the ROP margin-to-trip during normal operation. In addition, full power operation can be threatened. In this point, to recover ROPT margin, channel power needs to be redistributed. ROPT setpoint is very conservative in normal operation because distortion of regional overpower is over 1.2 times as nominal power in slow loss of regulation (SLOR). Channel power ratio (CPR) is enough low except the limiting channel of which worst case of design basis flux shape. If the outer channel power is slightly increased ...

2007-07-01

269

Display concepts for maintaining alarm state overview during unit evolutions  

Energy Technology Data Exchange (ETDEWEB)

Control room operators rely on the plant annunciation system to alert them to abnormal operating conditions and changes in plant configuration. A key determinant in annunciation system effectiveness is how well the annunciation system displays support Operations staff to staff to maintain a full understanding of the alarm state and ongoing changes under all operating situations. During unit evolutions, current CANDU alarm generation rates can frequently exceed 10 alarms per minute. With existing annunciation displays that list individual alarm changes, the rapid changes in display presentation can exceed an operator's ability to recognize the changes and maintain a full and up-to-date awareness of unit alarm state. This paper describes annunciation display features and concepts for alternative presentation of unit alarm state and changes that can provide improved support to Operations staff during unit evolutions. (author)

2009-07-01

270

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

Energy Technology Data Exchange (ETDEWEB)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The reason is because the content of Cr in the material of feeder pipes of Wolsung units 2, 3 ...

2007-07-01

271

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

International Nuclear Information System (INIS)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The reason is because the content of Cr in the material of feeder pipes of Wolsung units 2, 3 ...

2007-05-10

272

CFD Analysis of a Dry Storage System for MACSTOR/KN-400  

International Nuclear Information System (INIS)

There are four nuclear power plants in operation at Wolsong and, annually, more than 5,000 assemblies of spent nuclear fuels are released from each plant. Thus the concrete silo type dry storage system was constructed from '90. However, after 2006, another dry storage facility is required to accept the all amount of spent nuclear fuels from the plants. Instead of the concrete silo type, MACSTOR/KN-400 was developed to store the CANDU spent nuclear fuel more densely. In this study, computational fluid dynamics (CFD) analysis of the MACSTOR/KN-400 model was performed to confirm the thermal integrity of the facility, especially for the concrete structure, using the commercial CFD code, FLUENT. The MACSTOR/KN-400 which has Thermal Insulation Panel (TIP) and IAEA Re-verification Pipe (RVP) was modeled and analyzed in the view point of the thermal integrity of the concrete structure.

2007-10-01

273

An analysis of initial thickness and thinning status of feeder pipes in Wolsung unit 1  

Energy Technology Data Exchange (ETDEWEB)

The initial thichnesses of feeder pipes in Wolsung-1 are analyzed to estimate status of feeder thinning. The assumption of the estimation is that feeders of same type are decreased to same thickness by bending and have same thickness after bending. Following three methods are used to estimated thicknesses of the remains besides 52 feeders with initial thickness data in Wolsung-1. First is the estimating initial thickness of same type in Wolsung-1 from initial thickness data of Wolsung-2, -3 and -4. Second is the finding average value of each type from 52 initial thickness data of Wolsung-1. Last is the finding the thickness-after-bending of Wolsung-1 from thickness decrease rate of each type by bending in Wolsung-2, -3 and -4. The first method is eliminated by thickness-before-bending of Wolsung-1 lower than that of Wolsung 2, 3 and 4. The thinning rates of 2nd and 3rd method are compared with the {sup C}ANDU Feeder FAC Rate Analysis model' developed by ...

2001-05-01

274

An analysis of initial thickness and thinning status of feeder pipes in Wolsung unit 1  

International Nuclear Information System (INIS)

The initial thichnesses of feeder pipes in Wolsung-1 are analyzed to estimate status of feeder thinning. The assumption of the estimation is that feeders of same type are decreased to same thickness by bending and have same thickness after bending. Following three methods are used to estimated thicknesses of the remains besides 52 feeders with initial thickness data in Wolsung-1. First is the estimating initial thickness of same type in Wolsung-1 from initial thickness data of Wolsung-2, -3 and -4. Second is the finding average value of each type from 52 initial thickness data of Wolsung-1. Last is the finding the thickness-after-bending of Wolsung-1 from thickness decrease rate of each type by bending in Wolsung-2, -3 and -4. The first method is eliminated by thickness-before-bending of Wolsung-1 lower than that of Wolsung 2, 3 and 4. The thinning rates of 2nd and 3rd method are compared with the "CANDU Feeder FAC Rate Analysis model' developed by KEPRI and AECL. ...

2001-05-01

275

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

Energy Technology Data Exchange (ETDEWEB)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described in this paper. This approach is expected to assist utilities ...

2007-07-01

276

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

International Nuclear Information System (INIS)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described in this paper. This approach is expected to assist utilities respond to ...

2007-08-19

277

The THIRST chemistry module as a tool to determine optimal steam generator corrosion control strategies  

Energy Technology Data Exchange (ETDEWEB)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified with the respect of stress corrosion cracking susceptibility. The effects of lead contamination on the ...

2006-07-01

278

A study on the management of spent fuel storage capacity in South Korea  

International Nuclear Information System (INIS)

The saturation of South Korea's at-reactor (AR) spent fuel storage pools will create a necessity for additional spent fuel storage capacity. Because the South Korean government has the plan to increase the number of nuclear power plants from 20 units (end of 2005) to 27 units by 2015, the increase of spent nuclear fuel generation will be accelerated. Because there is no clear national plan for spent nuclear fuel storage and disposal, the utility company (Korea Hydraulic Nuclear Power company) is planning to construct a spent fuel storage facility with 11 000 tHM capacity for Pressurised Water Reactor (PWR). This study is intended to predict the maximum allowable periods when the storage facility will be fully occupied with respect to the already fixed re-racking plan of spent fuel storage pools and construction of new nuclear power plants. The result from this study will be used as fundamental data for an efficient management of the spent fuel storage capacity up ...

2006-06-19

279

Regulatory quality assurance requirements for the operation of nuclear R and D facilities in Korea  

International Nuclear Information System (INIS)

Full text: Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation. including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently. nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. All provisions on nuclear safety regulation and radiation protection are entrusted to the Atomic Energy Act(AEA). The Act is enacted as the main law concerning the safety regulation of nuclear installations, and is supplemented by the Enforcement ...

2006-10-15

280

Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test  

Energy Technology Data Exchange (ETDEWEB)

The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring ...

1999-03-01

281

Optical Fiber Sensor Package Development for the SIT of Containment Structure  

International Nuclear Information System (INIS)

Various types of nuclear power plants are being constructed and operated in Korea, and in terms of regulatory control, a method of examining and evaluating the structural integrity of containment structure is being used. Generally, after the construction has been completed, all containment structure go through a Structural Integrity Test(hereinafter SIT) in which the displacement occurring in a structure under greater internal pressure than it was designed for is measured and the result is comparatively assessed with the allowed criteria. Most of the nuclear power plants in Korea are American type plants and their SIT uses the Invar-wire and Extensometer methods. These existing methods are expected to be used for the APR1400 plant currently being built unless some other reliable alternative technique is presented. This tendency can be observed in other countries, such as Japan, and there is thus insufficient effort to enhance the reliability of SIT through the implementation of the ...

2010-10-01

282

Laser Sensor Package Development for the SIT of Containment Structure  

International Nuclear Information System (INIS)

Various types of nuclear power plants are being constructed and operated in Korea, and in terms of regulatory control, a method of examining and evaluating the structural integrity of containment structure is being used. Generally, after the construction has been completed, all containment structure go through a Structural Integrity Test(hereinafter SIT) in which the displacement occurring in a structure under greater internal pressure than it was designed for is measured and the result is comparatively assessed with the allowed criteria. Most of the nuclear power plants in Korea are American type plants and their SIT uses the Invar-wire and Extensometer methods. These existing methods are expected to be used for the APR1400 plant currently being built unless some other reliable alternative technique is presented. This tendency can be observed in other countries, such as Japan, and there is thus insufficient effort to enhance the reliability of SIT through the implementation of the ...

2010-10-01

283

Korea-Japan joint research on development of seismic capacity evaluation and enhancement technology considering near-fault effect (annual report 2004)  

Energy Technology Data Exchange (ETDEWEB)

In Chapter 2 the evaluation methods of input ground motions for seismic design are summarized and especially the empirical and/or stochastic Green's function method is introduced in order to calculate the broadband strong motions based on the physically reliable fault model. Then the evaluation procedure is applied to the Ulsan fault system near which Wolsung nuclear power plant is located. In chapter3, the PSHA case studies for Wolsung NPP site are performed, in which multi attenuation equations of earthquake motions are adopted. Moreover, the results of seismic hazard evaluation for eight sites in Korea are shown. In addition, the contents of two literatures on seismic hazard evaluation are introduced. In chapter 4, isolation devices for emergency diesel generator have been studied. The models for friction-pendulum system, high damping rubber bearing and natural rubber bearing are developed and implemented in the TDAP-III. Then, the rubber bearings as the isolation system ...

2004-12-01

284

Korea-Japan Joint Research on Development of Seismic Capacity Evaluation and Enhancement Technology Considering Near-Fault Effect (Final Report)  

Energy Technology Data Exchange (ETDEWEB)

We compiled the results of the source analysis obtained under the collaboration research. Recent construction scheme for source modeling adopted in Japan is described, and strong-motion prediction is performed assuming the scenario earthquakes occurring in the Ulsan fault system, Korea. Finally Qs values beneath the Korean inland crust are estimated using strong-motion records in Korea from the 2005 Off West Fukuoka earthquake (M7.0). Probabilistic seismic hazard for four NPP sites in Korea are evaluated, in which the site specific attenuation equations with Index SA developed for NPP sites are adopted. Furthermore, the uniform hazard spectra for the four NPP sites in Korea are obtained by conducting the PSHA by using the attenuation equations with the index of response spectra and seismic source model cases with maximum weights. The supporting tools for seismic response analysis, the evaluation tool for evaluating annual probability of failure, and system analysis ...

2006-12-15

285

Korea-Japan Joint Research on Development of Seismic Capacity Evaluation and Enhancement Technology Considering Near-Fault Effect  

Energy Technology Data Exchange (ETDEWEB)

Several recent improved methods for the EGFM are introduced in order to avoid artificial holes seen in the synthetic acceleration spectrum. Furthermore evaluation of input ground motions at Wolsung NPP are performed by varying the source parameters that may control the high-frequency wave radiation and the deviation of the synthetic motions are revealed. The PSHA case studies for four NPP sites (Wolsung, Kori, Uljin, Younggwang) are performed. In the analysis, site-specific attenuation equations developed for Korean NPP sites are employed, and the seismic hazards for the target sites are evaluated in the case where the four kind of seismic source models are considered. Moreover, the PSHA for Wolsung and Younggwang are conducted by using the site-specific attenuation equation with the index of response spectra and the uniform hazard spectra are evaluated for the two sites. The supporting tool for seismic response analysis and the evaluation tool for evaluating ...

2005-12-15

286

Estimation of the Alpha Factor Parameters for the Emergency Diesel Generators of Ulchin Unit 3  

Science.gov (United States)

Up to the present, the generic values of the Common cause failure (CCF) event parameters have been used in most PSA projects for the Korean NPPs. However, the CCF analysis should be performed with plant specific information to meet Category II of the ASME PRA Standard. Therefore, we estimated the Alpha factor parameters of the emergency diesel generator (EDG) for Ulchin Unit 3 by using the International Common-Cause Failure data Exchange (ICDE) database. The ICDE database provides the member countries with only the information needed for an estimation of the CCF parameters. The Ulchin Unit A3, pressurized water reactor, has two onsite EDGs and one alternate AC (AAC) diesel generator. The onsite EDGs of Unit 3 and 4 and the AAC are manufactured by the same company, but they are designed differently. The estimation procedure of the Alpha factor used in this study follows the approach of the NUREG/CR-5485. Since we did not find any qualitative difference between the ...

2006-07-01

287

Estimation of the Alpha Factor Parameters for the Emergency Diesel Generators of Ulchin Unit 3  

International Nuclear Information System (INIS)

Up to the present, the generic values of the Common cause failure (CCF) event parameters have been used in most PSA projects for the Korean NPPs. However, the CCF analysis should be performed with plant specific information to meet Category II of the ASME PRA Standard. Therefore, we estimated the Alpha factor parameters of the emergency diesel generator (EDG) for Ulchin Unit 3 by using the International Common-Cause Failure data Exchange (ICDE) database. The ICDE database provides the member countries with only the information needed for an estimation of the CCF parameters. The Ulchin Unit A3, pressurized water reactor, has two onsite EDGs and one alternate AC (AAC) diesel generator. The onsite EDGs of Unit 3 and 4 and the AAC are manufactured by the same company, but they are designed differently. The estimation procedure of the Alpha factor used in this study follows the approach of the NUREG/CR-5485. Since we did not find any qualitative difference between the ...

2006-07-17

288

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, the PGS system was ...

2007-09-21

289

Depositional environments and tectonic controls on the coal-bearing Lower to Middle Jurassic Yan'an Formation, southern Ordos Basin, China  

Energy Technology Data Exchange (ETDEWEB)

The Ordos Basin of north-central China is well known for vast energy resources. This nonmarine interior basin developed on the North China-Korean platform following the Late Triassic Indochina orogeny and, for a time, contained a large freshwater lake prior to being uplifted into its present form at the close of the Mesozoic. Lower to Middle Jurassic coal occurs in the fluviolacustrine Yan'an Formation along the southern margin of the basin in the Huanglong coalfield. In the northeast part of the field, the formation ranges from 0 to 180 m in thickness and is divided into five fining-upward members, each representing a regressive-transgressive lacustrine cycle. Low-sulfur, high-volatile bituminous coal is complexly distributed in the lowest member of the Yan'an Formation. Deposition of this member was influenced by two tectonic events that controlled coal occurrence. First, regional uplifts were produced by the Late Triassic Indochina orogeny and ...

1989-12-01

290

A study on the regulatory approach of KNGR multiple failure events  

Energy Technology Data Exchange (ETDEWEB)

This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in establishing regulatory requirements are ...

2001-01-15

291

A Demonstration of Level-2 Risk Uncertainty Decreasing Efforts for a Phenomenological Accident Progression Prediction  

Energy Technology Data Exchange (ETDEWEB)

An uncertainty decrease is an very important issue for enhancing risk-informed (RI) activities worldwide. Especially, a relatively large uncertainty in a level-2 (L2) PSA risk compared with level-1 internal PSA risk has been a bottleneck problem in the RI application to the extent of a severe accident management. According to the ASME PRA standard in which sources of an uncertainty to capture a category-II RI (= Option 2) capability are listed, an uncertainty analysis which identifies the key sources of an uncertainty and includes sensitivity studies for dominant contributors to LERF (Large Early Release Frequency) needs to be provided. To solve these problems, USNRC have developed the 'SPAR-LERF' model related to the L2 RI application and 'L2 uncertainty assessment and improvement' work is being taken as a main PSA2 topic of the SARNET (Severe Accident Research Network of Excellence) program in Europe by OECD/NEA. Domestically, a mid/long-term R and ...

2007-07-01

292

Alloy 800 SG tubing: current status and future challenges  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio ({>=}12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those that can arise as a ...

2007-07-01

293

Alloy 800 SG tubing: current status and future challenges  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio (#>=#12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those that can arise as a ...

2007-08-19

294

Transmutations of nuclear waste. Progress report RAS programme 1995: Recycling and transmutation of actinides and fission products  

Energy Technology Data Exchange (ETDEWEB)

This report describes the progress of the Dutch RAS programme on `Recycling and Transmutation of Actinides and Fission Products` over the year 1995, which is the second year of the 4-year programme 1994-1997. An extensive listing of reports and publications from 1991 to 1995 is given. Highlights in 1995 were: -The completion of the European Strategy Study on Nuclear Waste Transmutation as a result of which the understanding of transmutation of plutonium, minor actinides and long-lived fission products in thermal and fast reactors has been increased significantly. Important ECN contributions were given on Am, {sup 99}Tc and {sup 129}I transmutation options. Follow-up contracts have been obtained for the study of 100% MOX cores and accelerator-based transmutation. - Important progress in the evaluation of CANDU reactors for burning very large amounts of transuranium mixtures in inert matrices. - The first RAS irradiation experiment in the HFR, in which the ...

1996-04-01

295

Third RAAN conference: RAAN as Support of Nuclear Power  

International Nuclear Information System (INIS)

The proceedings of the third RAAN conference, titled 'RAAN as Support of Nuclear Power', held in Drobeta Turnu-Severin, Romania on 6-7 Nov 2003, are structured on three sections covering the following issues: - Section 1. Energy and Environment (19 papers); - Section 2. Isotopic products (3 papers); - Section 3. Prospects of Nuclear Power development in Romania (17 papers). Nuclear power in Romania was initiated on the basis of CANDU reactor type technology, an option found able to fulfill the requirements for a sustainable economic development, to support the electric energy demand of the country and to ensure the population and environment protection. The construction of the Cernavoda NPP was heavily based on the Romanian industry participation and basic and applied nuclear research national resources. The experience acquired from Cernavoda NPP Unit 1 will be fruitfully used in construction of the Units 2-5 to be built. Lately Romania's economy recorded a ...

2004-11-06

296

Steam generator access modification and waterlance cleaning for Wolsong and other nuclear plants  

International Nuclear Information System (INIS)

Steam generators for nuclear plants require access to the primary and secondary side for various inspection, cleaning and repair procedures and upon achieving access various inspection and cleaning tasks must be carried out. Steam generators currently at manufacture are therefore provided with; primary side access via the primary manways, steam drum access via the steam drum manway, U-bend region access via the secondary manway and drum-internals access passages, tubesheet secondary side access via tubesheet level inspection ports and tube support plate access via tube support level access ports. Many CANDU steam generators were built with only primary and drum manways and either no tubesheet ports or ports which were located ineffectively. The steam generators at Wolsong 1 were built with secondary side inspection ports that provided only limited access away from the no-tube-lane. In addition they have very difficult internal no-tube-lane access. Likewise, Units ...

2002-05-05

297

RAAN Conference. Support of Nuclear Power. Opening talk  

International Nuclear Information System (INIS)

Nuclear power in Romania was initiated on the basis of CANDU reactor type technology, an option found to fulfill the requirements for a sustainable economic development, to support the electric energy demand of the country and to ensure the population and environment protection. The construction of the Cernavoda NPP was heavily based on the Romanian industry participation and basic and applied nuclear research national resources. The experience acquired from Cernavoda NPP Unit 1 will be fructified in the construction of Units 2-5 to be built. The Romanian Ministry of Education and Research implemented a nuclear national program for research and development taking into account the European Union requirements and recommendations, the cooperation with the IAEA - Vienna and the Romanian government policy on short and medium terms in the nuclear field. The research-development program targeted: the reactor physics and nuclear fuel management; the operation safety of ...

2002-09-06

298

Pipe whip experiments involving impacts between pipes  

International Nuclear Information System (INIS)

Dynamic pipe impact tests were performed in order to determine the impact conditions for which a 2 inch Schedule 80 carbon steel target pipe would not be broken if it were impacted during a pipe whip event created by a postulated break of an adjacent larger parallel pipe. Such pipe/pipe impact scenarios are of special interest for the feeder pipes of a CANDU reactor because the large number of closely spaced parallel feeder pipes that carry coolant between large primary system pipes and individual fuel channels in the reactor core makes it impractical to consider providing feeder pipe whip restraints. The testing which was performed involved simulating the behaviour of 3 inch and larger whipping pipes in order to study their impact with 2 inch target pipes pressurized at about 9 MPa with water at a temperature of about 290"0C. In a conservative simulation of the worst pipe/pipe impact event which it has been predicted could occur for adjacent parallel feeder pipes ...

299

Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66{approx}8.91 x 1025 n/m{sup 2}) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4{approx}6 times faster DHC velocity(5.298E-0.8{approx}7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was seen DHC fracture surface at irradiated specimen showed much ...

2003-10-01

300

Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube  

International Nuclear Information System (INIS)

The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66#approx#8.91 x 1025 n/m"2) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4#approx#6 times faster DHC velocity(5.298E-0.8#approx#7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was seen DHC fracture surface at irradiated specimen showed much smaller ...

2003-10-01

301

Effect of lead and silicon on localized corrosion of Alloy 800 in steam generator crevice environments  

Energy Technology Data Exchange (ETDEWEB)

The Alloy 800 tubes used in CANDU 6 steam generators have not experienced significant corrosion damage to date, which may be attributed to successful water chemistry control strategies. However, it is known that Alloy 800, like other steam generator (SG) tubing materials, is not immune to corrosion, especially pitting, under some plausible but off-specification operating scenarios. Electrochemical measurements provide information on corrosion susceptibility and rate, which are known to be a function of water chemistry. Using laboratory data in combination with chemistry monitoring and diagnostic software it is possible to assess the impact of plant operating conditions on SG tube corrosion for plant life management (PLIM). In this context, this paper discusses the results of electrochemical measurements made to elucidate the corrosion behaviour of Alloy 800 SG tubes under conditions simulating those plausible in SG crevices. In addition to crevice pH, the influence ...

2001-09-01

302

Effect of design improvements in heavy water management systems to reduce heavy water losses and tritium releases at Wolsong 2,3 and 4  

International Nuclear Information System (INIS)

Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of expected heavy water and tritium releases has been performed for Wolsong 2, 3 and 4. CANDU 6 plants continue to perform well in that heavy water losses are small and ...

1994-03-01

303

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

Energy Technology Data Exchange (ETDEWEB)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second bends with similar ...

2006-07-01

304

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

International Nuclear Information System (INIS)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second bends with similar ...

2005-11-20

305

Development on the technologies for tritium removal processes  

Energy Technology Data Exchange (ETDEWEB)

While tritium exposure to the site-workers in Wolsung NPP is upto about 40 % of the total personnel exposure, Korea Institute of Nuclear Safety has asked tritium removal facility, as one of the requirements for post reactor construction, after operation of four CANDU reactors in Wolsung site. For the purpose of essential removal of tritium from the heavy water system of the heavy water reactors, an experiment of Ar-N{sub 2} cryogenic distillation tower was carried out as a preliminary study for development of liquid-phase catalytic exchange - cryogenic hydrogen distillation process. The steady-state reached after 50 minutes under 90 K in the Ar-N{sub 2} distillation column (inner diameter 20 mm, height 500 mm) packed with Dixon ring ({phi} 3 mm x H 3 mm), and the ratios of Ar-concentration at the top and at the bottom measured by gas chromatography within {+-}1 % relative error was approximately 93 : 3. This value was distillation performances quite higher than ...

1994-12-01

306

Development of a numerical methodology to simulate the roller expansion forming process  

International Nuclear Information System (INIS)

A distinguishing design feature of CANDU nuclear reactors is the use of horizontal fuel channels housed in a horizontal vessel called a calandria, which is made of stainless steel 304L. Each channel consists of a Zr-2.5%Nb alloy pressure tube and an externally concentric Zr-2 calandria tube. The calandria tubes are joined to the end plates (tubesheets) of the calandria vessel by joints formed by roller expansion. The bores in the tubesheets are grooved. Roller expanded joints provide a cost effective means of joining dissimilar materials, require minimal space and no maintenance. The quality of these roller expanded joints is important from a sealing, strength and stress corrosion point of view. The roller expansion process consists of expanding the calandria tubes to deform them plastically against the bores and into the grooves of the tubesheets. Therefore, understanding the effect of the number, geometry and the pitch of the grooves on the quality of a roller ...

2006-04-03

307

Bitumen immobilization of aqueous radwaste by thin-film evaporation  

International Nuclear Information System (INIS)

In the early 1980s, AECL built a Waste Treatment Centre (WTC) for managing low-level solid and aqueous liquid wastes for converting CANDU wastes. At present, two liquid waste streams are being treated at the WTC. The liquid waste streams are volume-reduced by a combination of continuous crossflow microfiltration (MF), spiral wound reverse osmosis (SWRO) and tubular reverse osmosis (TRO) membrane technologies. The concentrate produced from the TRO system and the volume-reduced MF backwash solutions are evaporated while simultaneously adding bitumen in a thin-film evaporator. A water-free product of chemical and radiochemical salts and bitumen is removed in 200-L galvanized steel drums for storage. The radiation field of product drums on contact typically has a value of 0.5 to 3 R/h depending upon the feed concentration of radioactivity to the evaporator. The total solids content in the 200-L drum ranges from 25 to 35%. Encapsulated in the bitumen matrix are a ...

1996-02-25

308

Annual report on heavy water reactor fuel fabrication  

Energy Technology Data Exchange (ETDEWEB)

The CANDU-type nuclear fuel localization project started in 1981, and mass-production system completed in 1987 through the pilot scale demonstration of fuel manufacturing. Since the completion of the mass-production system, about 24,000 fuel bundles (450 ton-U) had been delivered to Wolsung Nuclear Power Plant by the end of 1992, according to the fuel supply contracts with KEPCO. The superiority of KAERI-made nuclear fuel has been demonstrated by having achieved the highest utilization factor in the world in 1992. In 1993, as contracted, 4,824 fuel bundles well fabricated and delivered to Wolsung Nuclear Power Plant. The process improvement, quality control, safety management, safeguards of nuclear materials and various kinds of audits have also been performed in the course for fuel manufacturing. Especially in 1993, the difficulties of the reduction of participating work-force were overcome by improving the manufacturing techniques, and raising the efficiency of ...

1994-03-01

309

Development of Guide System for a Reactor Head Maintenance Robot  

Energy Technology Data Exchange (ETDEWEB)

The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been developed to address CRD nozzle inspection and repair issues. ...

2005-07-01

310

Multivariate statistics in the identification of unknown nuclear material  

International Nuclear Information System (INIS)

The identification, and hence origin determination, of unknown nuclear material that might be found undeclared away from designated locations in the nuclear fuel cycle, is an important task in the frame of nuclear forensics. Material with forensic importance can be found at the microscopic level as particles in environmental samples indicating possible clandestine production of fissile material, and as bulky samples in the case of illicit trafficking of nuclear material. The objective of this work is to present, at a theoretical level, an isotopic finger-printing methodology which would determine the origin of unknown nuclear material with forensic importance. This is demonstrated for the case when the unknown nuclear material is spent nuclear fuel. The methodology is based on multivariate statistics, such as cluster and factor analysis, complemented by spent fuel isotopic composition simulations using the zero-dimensional depletion computer code ORIGEN2. A major source of error in the ...

2004-10-25

311

Case studies: Experience in China [Factors affecting public and political acceptance for the implementation of geological disposal  

International Nuclear Information System (INIS)

China operates 10 nuclear power reactors and has 5 more under construction. A large extension of nuclear power is expected by 2020. Nuclear generated electricity accounts for 2% of the total electric power generation. The Chinese policy is to have spent fuel reprocessed in China. So, final disposal include vitrified waste and some CANDU spent fuel for direct disposal. There is a legal framework in place in China to manage HLW. The China Atomic Energy Authority (CAEA) has the responsibility for setting policy on HLW disposal and implementing the disposal programme, while the National Nuclear Safety Administration (NNSA) and the State Environment Protection Agency (SEPA) are the regulatory bodies, which are responsible for licensing and reviewing of environment impact assessment report. The China National Nuclear Corporation (CNNC) is considered to be the actual implementer, conducting the major activities for HLW management. In the 1980's, China started generic ...

2007-10-01