WorldWideScience
1

Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki  

Energy Technology Data Exchange (ETDEWEB)

A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)

2000-01-10

2

Analysis of exhaust gas visibility in iron ore sintering plant  

Energy Technology Data Exchange (ETDEWEB)

Visible smoke of exhaust gas from iron ore sintering plants spoil the scenery around the works. In this paper, the mechanism of formation of visible smoke is discussed by detailed analysis of the exhaust gas components and dust in the Oita No. 1 sintering plant. The main substance of visible smoke was mist condensing in the air during the cooling of exhaust gas that contained 0.1 ppm of sulfuric acid. Sulfuric acid is considered to raise the dew point and so facilitate mist condensation, and to lower the vaporization of visible mist containing sulfuric acid solution. Dust in the exhaust gas is also considered to act as nucleation sites for mist condensation. This proposed mechanism was confirmed by the test remixing SOx-rich gas with desulfurization gas in the Nagoya No. 3 sintering plant. Long trails of visible smoke were observed by remixing SOx-rich gas with exhaust gas. In conclusion, in order to make exhaust gas ...

2006-07-01

4

Hazards of explosives dusts  

Energy Technology Data Exchange (ETDEWEB)

The Bureau of Mines has investigated the hazards of military explosives dispersed as dust clouds in a 20-L test chamber. For purposes of personnel safety, the spark ignitability of the explosives in the form of unconfined dust layers was also studied. The 20-L data show that most of the explosives dusts were capable of sustaining explosions as dust clouds dispersed in air and some dusts were even capable of sustaining explosions when dispersed in nitrogen. The finest sizes of explosives dusts were less reactive than the larger sizes; this is opposite to the particle size effect observed previously for the pure fuel dusts. The data for the explosives dusts were compared to those for pure fuel dusts. 27 refs., 47 figs.

1989-01-01

5

Cloud Formation and Dynamics in Cool Dwarf and Hot Exoplanetary Atmospheres  

CERN Document Server

The lowest-mass stars, brown dwarfs and extrasolar planets present challenges and opportunities for understanding dynamics and cloud formation processes in low-temperature atmospheres. For brown dwarfs, the formation, variation and rapid depletion of photospheric clouds in L- and T-type dwarfs, and spectroscopic evidence for non-equilibrium chemistry associated with vertical mixing, all point to a fundamental role for dynamics in vertical abundance distributions and cloud/grain formation cycles. For exoplanets, azimuthal heat variations and the detection of stratospheric and exospheric layers indicate multi-layered, asymmetric atmospheres that may also be time-variable (particularly for systems with highly elliptical orbits). Dust and clouds may also play an important role in the thermal energy balance of exoplanets through albedo effects. For all of these cases, 3D atmosphere models are becoming an increasingly essential tool for understanding spectral and ...

2009-01-01

6

Tests with cleaned and uncleaned gas on a pilot plant. Final report  

Energy Technology Data Exchange (ETDEWEB)

The possibilities for heat recovery in a cast iron melting furnace were studied. A cupola furnace which produces 40 tonnes steel per hour, produces 25,000 Nm/sup 3//h of flue gases which contain 16-22% CO. Taking into account the heat losses at the chimney where fumes are cooled to 200/sup 0/C the recoverable heat is about 12.4-10/sup 6/ kcal/h which mainly consists of combustion heat in CO. This study showed that the heat can be used for the production of electricity, which will be used in the plant. Recovery of 87 kWh of electricity per tonne of steel produced is possible. A steam turbine driven generator of 3.5 MW will be required. The combustion of the low calorific gas (approximately 400 kcal/Nm/sup 3/) has been studied and gave positive results: wet CO gas can be burnt without addition of methane and preheating of air is not required. The pilot plant consisting of a thermic system (combustion chamber and equipment to produce and condense steam without turbine ...

1986-01-01

7

Dynamics of southwest Asian dust particle size characteristics with ...  

Science.gov (United States)

dust measured in the Arabian Gulf region during UAE2 and examine the hypothesis that ... [8] UAE2 took place in the southern Arabian Gulf region in August and ...

8

Compaction of dust clumps in a protostellar cloud  

Energy Technology Data Exchange (ETDEWEB)

Necessary conditions are derived for compact aggregates of solid matter to develop from loose local clumps of dust grains in a contracting protostellar cloud.

1984-01-01

9

Aluminum-Zinc (Al-Zn) Dust Analyses for Recycling Purposes  

Science.gov (United States)

... Accession Number : ADA547552. Title : Aluminum-Zinc (Al-Zn) Dust Analyses for Recycling Purposes. Descriptive Note : Technical rept. ...

2011-08-01

10

Rocks, minerals, and a dusty world  

Energy Technology Data Exchange (ETDEWEB)

The Earth`s troposphere and hydrosphere contain abundant naturally generated dust. The ultimate source materials from which the terrestrially produced dust is generated are the various rock types exposed at the Earth`s surface. Natural dust is a composite of (1) lithic, primary mineral grains; (2) mineral grains formed by secondary chemical reactions; (3) volcanic ash and dust; (4) salts from sea sprays; (5) extra-terrestrial dust; and (6) biologic materials. In this paper the various pathways to the natural generation of dust (via the hydrologic cycle) will be discussed, and two geologically well-known natural dust sources will be described, paying particular attention to quantitative measurements of the dusts from these areas. General dust studies that provide data on possibly global background ...

1993-12-31

11

Imaging-based dust sensors: equipment and methods  

Science.gov (United States)

Dust detection and control in real time, represent one of the most challenging problem in all those environments where fine and ultrafine airborne particulate solids products are present. The presence of such products can be linked to several factors, often directly related and influenced by the working-production actions performed. Independently from the causes generating dust, airborne contaminants are an occupational problem of increasing interest as they are related to a wide number of diseases. In particular, airborne dusts are well known to be associated with several classical occupational lung diseases, such as the pneumoconiosis, especially at high levels of exposure. Nowadays there is also an increasing interest in other dust related diseases, from the most serious as cancer and asthma, to those related with allergies or irritation and other illnesses, also occurring at lower levels of ...

2004-05-01

12

Direct Stellar Radiation Pressure at the Dust Sublimation Front in Massive Star Formation: Effects of a Dust-free Disk  

Science.gov (United States)

In massive star formation (gsim 40 M sun) by core accretion, the direct stellar radiation pressure acting on the dust particles exceeds the gravitational force and interferes with mass accretion at the dust sublimation front, the first absorption site. Ram pressure generated by high accretion rates of 10-3 M sun yr-1 is thought to be required to overcome the direct stellar radiation pressure. We investigate the direct stellar irradiation on the dust sublimation front, including the inner accretion disk structure. We show that the ram pressure of the accretion disk is lower than the stellar radiation pressure at the dust sublimation front. Thus, another mechanism must overcome the direct stellar radiation pressure. We suggest that the inner hot dust-free region is optically thick, shielding the dust sublimation front from direct stellar irradiation. Thus, ...

2011-10-01

13

Complex plasma: dusts in plasma  

International Nuclear Information System (INIS)

Dust particles in a plasma are charged negatively and are subject to various types of forces, including a drag force by plasma particles and a force due to the collective nature of a plasma. Dust particles are found in a sheath in laboratories balanced by the gravitational force and the electric force, while dust particles in space are ubiquitous, including planetary magnetospheres and interstellar space. Because of the novel nature of a complex system involving plasma particles and dust particles in a collective way, the dusty plasma is often called a complex plasma. The complex plasma is characterized by two distinctly different scales in time and in space. The plasma with electrons, ions and neutrals is characterized by the collective motion with a fast time scale and a short wavelength, while the dust particles move in a slow time scale and a long spatial scale. Some fundamental ...

2007-04-21

14

The dust distribution in edge-on galaxies. Radiative transfer fits of V and K'-band images  

CERN Document Server

Aims: I have analyzed a sample of seven nearby edge-on galaxies observed in the V and K'-band, in order to infer the properties of the dust distribution. Methods: A radiative transfer model, including scattering, have been used to decompose each image into a stellar disk, a bulge, and a dust disk. The parameters describing the distributions have been obtained through standard X^2 minimization techniques. Results: The dust disks fitted to the V-band images are consistent with previous work in literature: the radial scalelength of dust is larger than that for stars (h_d/h_s ~ 1.5); the dust disk has a smaller vertical scalelength than the stellar (z_d/z_s ~ 1/3); the dust disk is almost transparent when seen face-on (central, face-on, optical depth tau_0 =0.5-1.5). Faster radiative transfer models which neglect scattering can produce equivalent fits, with changes ...

2007-01-01

15

The Structure of the Dust Mite Allergen Der p 7 Reveals Similarities to Innate Immune Proteins  

UK PubMed Central (United Kingdom)

BackgroundSensitization to house dust mite allergens is strongly correlated with asthma. Der p 7 elicits strong IgE antibody and T-cell responses in mite allergic...Full Text Available

2010-04-01

16

Species-specific Fungal DNA in Airborne Dust as Surrogate for Occupational Mycotoxin Exposure?  

UK PubMed Central (United Kingdom)

Possible health risks associated with occupational inhalation of mycotoxin-containing dust remain largely unknown, partly because methods for mycotoxin detection are not sensitive enough for the small...Full Text Available

17

El Roque de Los Muchachos Site Characteristics. III. Analysis of Atmospheric Dust and Aerosol Extinction  

CERN Document Server

Canary Islands are normally interested by dominant North-East winds that, in some meteorological conditions, can transport sand at high altitude from the Sahara desert. The dust may affect the efficiency of the telescopes and decreases the transparency of the sky. In order to maximize the scientific return of the telescopes located at the ORM, we present an analysis of the atmospheric dust content and its effects on astronomical observations. B, V and I dust aerosol astronomical extinction are derived. Using a 5 years series database of data taken from the four channel TNG dust monitor, we compute a mean hourly and daily values of the dust content. We have detected particles having size 0.3, 0.5, 1.0 and 5.0 um. Using a power law we have derived the content of 10.0 um particles. We found a typical local dust concentration ranging from 3x10^6 particles per cubic ...

2008-01-01

18

EF Cha: Warm Dust Orbiting a Nearby 10 Myr Old Star  

CERN Document Server

Most Vega-like stars have far-infrared excess (60micron or longward in IRAS, ISO, or Spitzer MIPS bands) and contain cold dust (~ 4% of the stars in nearby young stellar associations.

2007-01-01

19

Decrease in dust content and removal of sludge during drilling ascending shafts in coal  

Energy Technology Data Exchange (ETDEWEB)

Results are presented of analysis of the dust content of air and the resources for removing sludge at the mines of the Kuzbass during drilling of ascending shafts. A design is proposed for sludge removing devices with automatic opening and closing of the valve hinges.

1983-01-01

20

APOD: 2011 January 26 - The Whirlpool Galaxy in Infrared Dust  

Science.gov (United States)

Clicking on the image will bring up the highest resolution version available. The Whirlpool Galaxy in Infrared Dust Credit: Infrared: NASA, ESA, M. Regan & B. Whitmore (STScI),...

2011-10-07

21

APOD: 2004 September 5 - M51: The Whirlpool Galaxy in Dust and...  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy in Dust and Stars Credit: Credit: N. Scoville (Caltech), T. Rector (U....

2011-10-07

22

APOD: 2001 April 10 - M51: The Whirlpool Galaxy in Dust and Stars  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy in Dust and Stars Credit: N. Scoville (Caltech), T. Rector ( (NOAO) et al.,...

2011-10-07

23

A Controlled Challenge Study on Di(2-ethylhexyl) Phthalate (DEHP) in House Dust and the Immune Response in Human Nasal Mucosa of Allergic Subjects  

UK PubMed Central (United Kingdom)

BackgroundFew studies have yet addressed the effects of di(2-ethylhexyl) phthalate (DEHP) in house dust on human nasal mucosa.ObjectivesWe investigated...Full Text Available

2008-11-01

25

Fungi of the house dust in Riyadh, Saudi Arabia.  

Science.gov (United States)

30 species belonging to 18 genera were isolated from floor dust of 30 homes in Riyadh. Out of them 16 species and 10 genera were isolated from dust of air conditioners of the same homes. The most common genera in floor dust were Aspergillus, Penicillium and Cladosporium. Aspergillus repens, A. amstelodami, A. versicolor, A. fumigatus, Penicillium purpurogenum, P. crustosum, Cladosporium cladosporoides and C. herbarum were frequently isolated. The most abundant genera in air conditioner dust were Aspergillus and Penicillium. Aspergillus fumigatus, A. ochraceus, A. terreus, Penicillium oxalicium and P. crustosum were most frequent species. PMID:2330766

1990-01-01

26

Structures in the Universe and Origin of Galaxies  

CERN Document Server

The analysis of images (of obtained in various ranges of the lengths of waves) of luminous objects in the Universe by means of a method of multilevel dynamic contrasting led author to the conclusions: a) the structures of all observable galaxies represents a complicated constructions which have the tendency to self-similarity and made of separate (basic) blocks, which are a coaxially tubular structures and a cartwheel-like structures; b) the majority of observable objects in the Universe are luminous butt-ends of almost invisible (of almost completely transparent) of filamentary formations which structures are seen only near to their luminous butt-ends; c) the result of analysis of images of cosmic objects show the structure of many pairs of cooperating galaxies point to opportunity of their formation at butt-ends generated in a place of break of the similar filament; d) the interacting galaxies (M 81 and M 82) show they are butt-ends of sawed ...

2005-01-01

27

On the properties of plasma crystals  

Energy Technology Data Exchange (ETDEWEB)

When a plasma becomes contaminated by foreign particles, generically referred to as dust, the result is called a dusty plasma. At the present time there is a great deal of interest in dusty plasmas because of their roles in terrestrial and extra-terrestrial processes - semiconductor processing, high temperature fusion experiments, stellar formation and the rings of Saturn. This thesis is concerned with the role of dust in processing type plasmas. In the following experiments, artificial dust is introduced into a parallel electrode plasma chamber. Ions and electrons in the plasma charge the dust particles and they become suspended in the plasma due to the balancing of electric and gravitational forces. By illuminating the suspended dust with laser light and using an extremely high speed camera fitted with a macro lens to look at the scattered light, the dust ...

1999-07-01

28

Dust resuspension and transport modeling for loss of vacuum accidents  

Energy Technology Data Exchange (ETDEWEB)

Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, ...

2007-07-01

29

Dust resuspension and transport modeling for loss of vacuum accidents  

International Nuclear Information System (INIS)

Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, ...

2007-10-05

30

Cooling facility for reactor container  

International Nuclear Information System (INIS)

Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the ...

1993-05-07

31

Short rotation coppice harvesting: an evaluation of the Salix Maskiner Bender III  

Energy Technology Data Exchange (ETDEWEB)

Version III of the Salix Maskiner ``Bender`` coppice harvester was used to successfully harvest 11.2 hectares of short rotation poplar and willow coppice in February 1997. On a wide range of typical UK crop and site conditions, the Swedish harvester was shown to have productivity rates ranging from 4.28 to 7.97 odt/smh. Based on a total system cost of Pound 81.26 per scheduled machine hour, the Bender III is able to produce wood chip for between Pound 10.20 and pound 18.97 per dry tonne. The variation in machine productivity is dependent on crop productivity and working method, emphasising the importance of site design in optimising system efficiency. In willow crops the wood chip produced by the Bender III contained a significant amount of material greater than 75mm in length. The bulk of the chips however, fell into the 5-45mm category with only a very limited amount of fine materials less than 5mm in length. The chips from poplar crops were more uniform with the majority of material ...

1997-12-31

32

Preparation of immission dust samples for the analysis of toxic substances in dust by atomic emission spectroscopy with inductively coupled plasma  

International Nuclear Information System (INIS)

Samples of air-dust-concentration- and air-dust-deposit measurements were digested by a standardized wet digestion procedure and the amounts of substances in the dust according to class I TA Luft by Atomic Emission Spectroscopy with Inductively Coupled Plasma (AES-ICP). The characteristic values for procedures according to VDI 2449, sheet 1, were determined for lead, vanadium, cadmium, chromium, copper, nickel and zinc. By partial automatic control of the digestion procedure the personel expenditure of work could be reduced by a factor 13. Dust filter samples were analysed without sample preparation by evaporating the material with a solid state laser. The absolute detection limit was between 1 and 100 ng/cm"2 for the elements arsenic, cadmium, cobalt, chromium, mercury, antimony, selen and thallium. For sampling by means of the Beta-Staubmeter the relative detection limits for the laser-ICP were ...

33

Physico-chemical behaviour of a barrier composed of cement kiln dust and fly ash; Comportement physico-chimique d'une barriere a base de poussieres de four de cimenterie et de cendres volantes  

Energy Technology Data Exchange (ETDEWEB)

Controlling acid mine drainage is one of the most important challenges facing the mining industry. One of the solutions to this problem is the use of soil covers. In this poster presentation, the author described the development of a soil barrier composed of cement kiln dust and fly ash. In the study, four different cement kiln dust were associated to three different fly ash types, for a total of twelve different mix. The objective was to develop a stable environmental barrier. The origin of the cement kiln dust was described, followed by the characterization and preparation of the different mix, and the monitoring of the hydration process. The results were discussed, and indicated that a barrier composed of cement kiln dust and fly ash seemed to have great potential. The results also indicated that the fly ash improve the properties of the cement kiln dust, but that the improvement ...

2000-07-01

34

Design and analysis of a dust extraction system  

Energy Technology Data Exchange (ETDEWEB)

A dust extraction system removes the contaminated air at source by means of a hood. The extraction system for dust is essentially a ducted air system that prevents excessive employee exposure to dust in the working zone. The four major mechanisms that remove the contaminants in an extraction system are: - capture of contaminants by hoods - transport of contaminated air in duct network - separation of dust in the collector - exhaust of clean air through stack. The current methods of design are based on empirical relations, multi-variable tables, graphs and nomographs that have been derived from the principle of fluid mechanics and particle dynamics. However, the empirical formulae, tables and graphs are used in different geographical locations of the world having different environmental conditions and geo-characteristics of dust particles. Therefore, it is required to establish a ...

2006-07-01

35

Origin of binary stars  

Energy Technology Data Exchange (ETDEWEB)

Results of analytical study of early stages of a single star evolution are used investigation of the rotational fragmentation of the collapsing gas-dust cloud which leads to formation of two types of binaries. Wide ..cap alpha..-systems (Psub(orb) > or approximately 100 yrs) with usually unequal masses of components are formed before the formation of gas-dust core in hydrostatical equilibrium. Close ..beta..-systems (Psub(orb) < or approximation 100 yrs) with usually nearly equal masses of components are formed in the course of the collapse of gas-dust core.

1983-03-01

36

chapter 5 - NASA's History Office  

Science.gov (United States)

Ever-present water vapor and dust distort or block incoming radiations. ... were among the first scientific sensors to be attached to the earliest space rockets. ...

37

Waste and dust utilisation in shaft furnaces  

Energy Technology Data Exchange (ETDEWEB)

Wastes and dusts from steel industry, non-ferrous metallurgy and other branches can be utilised e.g. in agglomeration processes (sintering, pelletising or briquetting) and by injection into shaft furnaces. This paper deals with the second way. Combustion and reduction behaviour of iron- and carbon-rich metallurgical dusts and sludges containing lead, zinc and alkali as well as other wastes with and without pulverised coal (PC) has been studied when injecting into shaft furnaces. Following shaft furnaces have been examined: blast furnace, cupola furnace, OxiCup furnace and imperial-smelting furnace. Investigations have been done at laboratory and industrial scale. Some dusts and wastes under certain conditions can be not only reused but can also improve combustion efficiency at the tuyeres as well as furnace performance and productivity.

2005-07-01

38

Toward finding an optimal stockpile geometry to reduce dust emissions  

Energy Technology Data Exchange (ETDEWEB)

Fugitive dust emissions from stockpiles in the open storage yards of industrial zones and the subsequent atmospheric dust dispersion have brought about many ecological and economical problems. This paper introduces a new approach to reduce pollutant emissions by simply changing pile configuration and without affecting the operational activity on these parks. Flow around piles of different geometries and for various wind conditions was studied using previously validated Computational Fluid Dynamic (CFD) simulations. Different pile height scenarios were investigated corresponding to a constant material volume and a fixed angle of repose under various wind magnitudes. The results obtained were integrated in order to evaluate the rate of dust emissions for the various configurations considered. It was found that, for the range of wind conditions and pile dimensions tested, an optimal geometry exists which corresponds to the ...

2006-07-01

40

NASA - Spitzer Sees Spider Web of Stars  

Science.gov (United States)

star formation. To either side of the center, a small bar of dust and gas is helping to fuel the new stars. NASA's Jet Propulsion Laboratory, Pasadena, Calif., manages the...

2011-07-20

41

Lung cancer in rats exposed to fibrogenic dusts  

Energy Technology Data Exchange (ETDEWEB)

Fischer-344 rats were exposed to quartz dusts and to quartz-bearing oil shale dusts in long-term inhalation studies. Aerosol concentrations of 12 mg/m/sup 3/ and 152-176 mg/m/sup 3/ for quartz and shale dusts, respectively, were used in exposure regimens lasting up to two years. Pulmonary fibrosis was observed in most animals surviving beyond 400 days. Adenocarcinomas and epidermoid carcinomas of the lung were observed in animals from all exposure groups, including those exposed to quartz alone. The pulmonary tumors were a late effect, with the earliest lung tumor being observed after 651 days. 13 references, 10 figures, 4 tables.

1984-01-01

42

GALAXY EVOLUTION EXPLORER (GALEX) GUEST ... - GALEX - NASA  

Science.gov (United States)

star evolution, globular cluster structure and evolution, massive stars, supernova remnants, reflection nebulae, interstellar dust, structure of the ISM, ...

43

Comparative toxicity in rats vs hamsters of inhaled radon daughters with and without uranium ore dust  

International Nuclear Information System (INIS)

Simultaneous exposures of rats and hamsters to inhaled radon daughters, with and without uranium ore dust, were performed daily for five months. Pulmonary pathology developing in 6 to 13 mo after cessation of daily exposures included interstitial fibrosis, emphysema, epithelial hyperplasia, squamous metaplasia, and malignant neoplasia. Rats showed a greater variety and more severe response to these uranium mine inhalation exposures than did hamsters. Inhalation of radon daughters with uranium ore dust displayed the site of greatest damage, including squamous carcinoma, from the nasopharynx to the lungs. Sixty percent of the rats exposed to radon daughters with ore dust developed primary pulmonary carcinomas, providing an appropriate short-term experimental animal model for investigation of respiratory tract carcinogenesis in uranium miners.

1977-05-01

44

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

45

Evaluation of Two Microclimate Cooling Air Vests on a Heated ...  

Science.gov (United States)

... If the MCAV is used in conjunction with a cooling system designed for the CVC air vest, the wearer would receive more cooling due entirely to the ...

1992-12-01

46

The biokinetics of four sup 239 Pu/ sup 241 Am dioxide bearing dusts in the rat after inhalation: the implications for occupational exposure  

Energy Technology Data Exchange (ETDEWEB)

The aims of the work described here were to provide an experimental basis for evaluating the committed effective dose equivalent per unit intake together with the ALI for four industrial oxide bearing dusts, and to assess the extent to which {sup 241}Am could be used for estimating the {sup 239}Pu content of the lung after an accidental intake of these materials. (author).

1991-01-01

47

Rotational modes of oscillation of rodlike dust grains in a plasma  

CERN Document Server

Three dimensional rotatory modes of oscillations in a one-dimensional chain of rodlike charged particles or dust grains in a plasma are investigated. The dispersion characteristics of the modes are analyzed. The stability of different equilibrium orientations of the rods, phase transitions between the different equilibria, and a critical dependence on the relative strength of the confining potential are analyzed. The relations of these processes with liquid crystals, nanotubing, and plasma coating are discussed.

2003-01-01

48

Non-neoplastic pulmonary disease from inhaled radon daughters with uranium ore dust in beagle dogs  

International Nuclear Information System (INIS)

Daily exposures of adult beagle dogs to inhaled radon daughters plus uranium ore dust, with and without concurrent cigarette smoking, for 2 to 5-1/2 yr have produced massive pulmonary fibrosis and severe emphysema. The cumulative exposure doses are similar to those associated with a 5-fold or greater increase in death rate of uranium miners due to chronic respiratory insufficiency, including pneumoconiosis, pulmonary fibrosis, and emphysema.

1977-05-01

49

Mineralogy of clay and zeolite dusts (exclusive of 1:1 layer silicates)  

Energy Technology Data Exchange (ETDEWEB)

Clays and zeolites are among the most important of natural dusts by virtue of their occurrence through out the world on the earth`s surface and their important industrial uses. (The 1:1 layer silicates, including the serpentine and kaolin minerals, are not addressed in this chapter.) This chapter provides basic information on a variety of important aspects of each mineral, including crystal structure diagrams of each and references to more detailed discussions. 110 refs., 20 figs.

1993-12-31

50

Engineering health and safety in coal mining  

Energy Technology Data Exchange (ETDEWEB)

This book presents the papers given at a symposium on occupational safety in coal mines. Topics considered at the symposium included human factors, causes and prevention of personal injuries, remote sensing for ground control, respirable dust generation by continuous miners, accident analysis, hazard analysis of mining equipment, coal mine blasting accidents, coal mine respirable dust sampling, and noise in the mining industry.

1986-01-01

51

Dust and waterfree technology for demolition works in nuclear environments and other sensitive areas  

International Nuclear Information System (INIS)

At the University of Karlsruhe experiments were carried out from 1997 to 1999 to get fundamentals of flow characteristics of pneumatic extracted materials. The results could be used to develop a concept for demolition suitable for extraction and removing high-density concrete. The concept fulfills all demands of a closed nuclear area, especially of dust abatement. (orig.)

52

Changes in the Lung Lipids of Rabbits and Guinea-pigs Exposed to the Inhalation of Silica Dust  

UK PubMed Central (United Kingdom)

Eight rabbits and 24 guinea-pigs were exposed to a silica dust cloud of about 40,000 pp./ml. (0·3-3·0 μ) and killed at four-weekly intervals up to 30 weeks. The guinea-pigs showed...Full Text Available

1960-01-01

53

Carcinogenesis of inhaled radio daughters with uranium ore dust in beagle dogs  

International Nuclear Information System (INIS)

Daily exposures of adult beagle dogs to inhaled radon daughters and to uranium ore dust for 4-1/2 to 6 yr have produced respiratory tract carcinomas, at similar cumulative working level months (WLM) of exposures to those which induced carcinomas in uranium miners. Biological data from the beagle-dog experiments can therefore be used for prediction of carcinogenic risk under changing exposure conditions in future uranium miners.

1977-05-01

54

[Pilot-plant testing for flue gas desulfurization and dust removal by activated coke].  

Science.gov (United States)

A developed flue gas desulfurization and dust removal process with a cross-flow moving bed filled with activated coke (AC) was tested on a pilot scale with the gas treatment capacity of 1000 mg x h(-t). The results show that a easy-operating and stable-running pilot-scale testing equipment can be reached, and under the conditions of testing space velocity, the feed gas temperature of 120 degrees C, SO2 concentrations of 3232-6006 mg x m(-3) and dust concentration of 89.3-1599.7 mg x m(-3), the high efficiency of flue gas desulfurization and dust removal is reached with the purity of dust less than 50 mg x m(-3). In the technology, the spent AC was regenerated by heating, and the SO2 concentration in the desorption gas is about 40.1%, which can be efficiently recovered as a sulfur resource. Favorable economy benefit can be reached by using the process. PMID:16850821

2006-05-01

55

The photophoretic sweeping of dust in transient protoplanetary disks  

CERN Document Server

Protoplanetary disks start their lives with a dust free inner region where the temperatures are higher than the sublimation temperature of solids. As the star illuminates the innermost particles, which are immersed in gas at the sublimation edge, these particles are subject to a photophoretic force. We examine the motion of dust particles at the inner edge of protoplanetary disks due to photophoretic drag. We find that, in a laminar disk, photophoretic drag increases the size of the inner hole after accretion onto the central body has become subdued. This region within the hole becomes an optically transparent zone containing gas and large dusty particles (>>10 cm), but devoid of, or strongly depleted in, smaller dust aggregates. Photophoresis can clear the inner disk of dust out to 10 AU in less than 1 Myr. At late times, the edge reaches a stable equilibrium between inward drift and ...

2006-01-01

56

HST/ACS observations of shell galaxies: inner shells, shell colours and dust  

CERN Document Server

AIM:Learn more about the origin of shells and dust in early type galaxies. METHOD: V-I colours of shells and underlying galaxies are derived, using HST Advanced Camera for Surveys (ACS) data. A galaxy model is made locally in wedges and subtracted to determine shell profiles and colours. We applied Voronoi binning to our data to get smoothed colour maps of the galaxies. Comparison with N-body simulations from the literature gives more insight to the origin of the shell features. Shell positions and dust characteristics are inferred from model galaxy subtracted images. RESULT: The ACS images reveal shells well within the effective radius in some galaxies (at 1.7 kpc in the case of NGC 5982). In some cases, strong nuclear dust patches prevent detection of inner shells. Most shells have colours which are similar to the underlying galaxy. Some inner shells are redder than the galaxy. All six shell galaxies show out of dynamical ...

2007-01-01

57

MR-6 Type Fuel Elements Cooling in Natural Convection Conditions after Reactor Shutdown  

International Nuclear Information System (INIS)

... Natural convection cooling of the channel type reactor performed with the fuel

1992-08-03

58

Impingement-Film Heat Transfer Investigation.  

Science.gov (United States)

... Abstract : This report covers the investigation of an impingement-film cooling system designed to cool the exhaust ducts of turboshaft engines ...

1973-12-01

59

Design and performance tests of flap value for HANARO natural circulation cooling  

International Nuclear Information System (INIS)

... [2] Hee Taek Chae, et al., "On the Natural Convection Cooling in HANARO;

1999-09-06

60

Battery Thermal Management System Design Modeling  

Energy Technology Data Exchange (ETDEWEB)

Looks at the impact of cooling strategies with air and both direct and indirect liquid cooling for battery thermal management.

2006-11-01

61

The effects of various cooling strategies on surface roughness and tool wear during soft materials milling  

British Library Electronic Table of Contents (United Kingdom)

This work is focused on effect of various cooling strategies on surface roughness and tool wear during computer aided milling of soft workpiece materials. These milling operations were selected as dry milling, cool air cooling milling and fluid cooling milling. A cool air cooling system was designed and produced to cool end milling tools. Cool air was produced by a vortex tube. Annealed AISI 1050 was used as the workpiece material and cutting tool material was selected as HSS-Co8 DIN 844/BN. Optimal cutting parameters were selected according to workpiece hardness from reference catalog and kept for all tests. Tool wear and surface quality were measured for three different cooling types changing from ten minute machining time to thirty minute machining time. As a result, the surface roughne...

2009-01-01

62

Properties of dust particles sampled from windboxes of an iron ore sintering plant: Surface structures of unburned carbon  

Energy Technology Data Exchange (ETDEWEB)

Aiming to understand the formation mechanism of dioxins in the iron ore sintering process, dust samples obtained from some windboxes of a commercial iron ore sintering plant have been characterized with a powder X-ray diffraction (XRD), by the transmission electron microscope (TEM) equipped with an electron energy loss spectroscopy (EELS), and by the temperature-programmed desorption (TPD) and temperature-programmed oxidation (TPO) techniques. The elemental and XRD analyses reveal that the content of the Cl present in the samples ranges from 0.075 mass%-dry to 5.1 mass%-dry and tends to be higher at smaller dust particles, and that some of the Cl exists as KCl with the average crystalline size between 40 nm and 50 nm. Dust samples also contain a significant amount of unburned carbon, and the smallest dust particles, < 500 {mu}m, show the highest C contents in many cases and consist partly of C, ...

2006-07-01

63

Development of materials resistant to metal dusting degradation.  

Energy Technology Data Exchange (ETDEWEB)

Metal dusting corrosion has been a serious problem in the petroleum and petrochemical industries, such as reforming and syngas production systems. This form of deterioration has led to worldwide material loss for 50 years. For the past three years, we have studied the mechanism of metal dusting for Fe- and Ni-base alloys. In this report, we present a correlation between the weight loss and depth of pits that form in Ni-base alloys. Nickel-base alloys were also tested at 1 and 14.8 atm (210 psi), in a high carbon activity environment. Higher system pressure was found to accelerate corrosion in most Ni-base alloys. To reduce testing time, a pre-pitting method was developed. Mechanical scratches on the alloy surface led to fast metal dusting corrosion. We have also developed preliminary data on the performance of weldments of several Ni-base alloys in a metal dusting environment. Finally, Alloy 800 tubes ...

2006-04-24

64

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

65

Safety designs for sludge ducts in brown coal briquetting plants  

Energy Technology Data Exchange (ETDEWEB)

Studies technological safety of installing a water spray pressure vessel between electrostatic dedusters and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption; about 8/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer.

1987-06-01

66

Safe design of mud ditches in briquetting factories  

Energy Technology Data Exchange (ETDEWEB)

The authors study technological safety of installing a water spray pressure vessel between electrostatic deduster and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption: about 8 m/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer. (MOS).

1987-06-01

67

Observation of dust stream formation produced by low current, high voltage cathode spots  

International Nuclear Information System (INIS)

Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic macroparticles formed during this process.

2004-04-01

68

Metal dusting behaviour of welded Ni-base alloys with different surface finish  

Energy Technology Data Exchange (ETDEWEB)

Welded Ni-base alloys and Alloy 800 were exposed under metal dusting conditions at 600 C and 650 C for up to 6000 hours. Alloy 800 was attacked very strongly already in the first days and Alloy 600 also rather soon and widespread, on both materials attack started mainly in the heat affected zone. Several surface states of Alloy 600: brushed, ground, sand-blasted and pickled were tried only grinding caused a modest delay and decrease of metal dusting attack. Generally the attack was less widespread but deeper at 650 C than at 600 C, also for Alloy 601 and 602. The latter alloys show minor, mainly local attack, but especially the welds are affected. TIG welding led to better resistance than hand-welding. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

2003-10-01

69

In vitro evaluation of mineral cytotoxicity and inflammatory activity  

Energy Technology Data Exchange (ETDEWEB)

Health risks associated with inhalation of mineral dusts have been identified to a great extent through epidemiology studies, but also have been assessed by conducting subchronic and chronic inhalation studies typically on rodents. However, in vivo studies are softly, time-consuming, requiring complex technologies, and may not yield information on cellular and molecular mechanisms of response. As a result, the use of in vitro cell culture systems has played an important role in studying the toxicology of mineral dusts and providing insight into action mechanisms. This article reviews selected in vitro approaches that are used to investigate the cytotoxic and inflammatory properties of mineral particles and fibers. In addition key findings as they relate to understanding the toxicology of mineral dusts are presented. 165 refs., 1 fig., 5 tab.

1993-12-31

70

FG Sge at the stage of dust shell ejection  

British Library Electronic Table of Contents (United Kingdom)

New photometric observations of the variable star FG Sge, a rapidly evolving planetary nebula nucleus, were performed in 2003?2008. On 230 nights, we obtained 86 UBV and 155 BV RI (or R c , I c ) magnitude estimates. The maximum amplitude of the V-band light variations was >8 m . Six deep minima and four high maxima were observed. Analysis of the light curve has shown that the pulsation period of the star remained constant since 1991 and was P = 115 days. We have studied the wavelength dependence of the extinction at various phases of the light curve. The blueing of the B-V color at deep minima is interpreted as the result of light scattering in the circumstellar dust shell of the star formed by preceding dust ejections since 1992. Our spectroscopic observations performed on nine nights in...

2009-01-01

71

Design of a modern hot-blast cupola furnace  

Energy Technology Data Exchange (ETDEWEB)

Georg Fischer GmbH operates a melting plant with several cupola furnaces in Mettmann. The plant supplies two casting plants for production of castings from nodular cast iron or malleable cast iron. It is now planned to convert one of the existing hot-blast cupola furnaces to the latest state of the art. Under special consideration are clear reduction of dust emission by use of a filtering separator below the permissible mass concentration according to the Clean Air Regulations; reduction of the current level of dumped waste by application of a new dust (residue) utilisation method; improvement of the total thermal efficiency of the cupola furnace melting plant by extensive, advanced utilisation of waste heat; and use of low-cost dust-like alternative fuels. (author).

1990-01-01

72

Coal liquefaction catalysis by industrial metallic wastes  

Energy Technology Data Exchange (ETDEWEB)

Catalytic activity of industrial metallic wastes in coal liquefaction was examined in a 100lb/day continuous coal processing development unit. Red mud, a waste material from the aluminium industry, and an electric furnace flue dust containing Ni, Mo, Co and Fe showed a pronounced effect on the conversion of a Kentucky bituminous coal. Coal conversion and oil production increased significantly with the addition of red mud and flue dust. Comparison of the catalytic activity of pyrite, red mud, and flue dust, based on selectivity analysis, showed that red mud was the most desirable disposable catalyst. However, if the primary goal of coal liquefaction is high oil production, irrespective of hydrogen consumption, pyrite is the most active catalyst among those discussed in the paper.

1985-01-01

73

A novel approach to the dynamics of Szekeres dust models  

CERN Document Server

We obtain an elegant and useful description of the dynamics of Szekeres dust models (in their full generality) by means of "quasi--local" scalar variables constructed by suitable integral distributions that can be interpreted as weighed proper volume averages of the local covariant scalars. In terms of these variables, the field equations and basic physical and geometric quantities are formally identical to their corresponding expressions in the spherically symmetric LTB dust models. Since we can map every Szekeres model to a unique LTB model, rigorous results valid for the latter models can be readily generalized to a non--spherical Szekeres geometry. The new variables lead naturally to an initial value formulation in which all scalars are expressed as scaling laws in terms of their values at an arbitrary initial space slice. These variables also yield a significant simplification of numerical work, since the fluid flow evolution equations ...

2011-01-01

74

The cometary activity of Centaur P/2004 A1 (LONEOS)  

British Library Electronic Table of Contents (United Kingdom)

Abstract P/2004 A1 (LONEOS) is one of the few active objects in the dynamical class of Centaurs. It has been recently injected into an inner orbit with a perihelion distance-q-= 5.5 au. The aim of this paper is to characterize the dust coma of this peculiar object, 2.5 yr after its first -new- perihelion passage inside the Solar system. Broad-band visible images taken at the TNG telescope in 2007 February were analysed in order to characterize the dust coma of the Centaur: it was still quite active at-rh-= 6.5 au post-perihelion, with a coma and a well-developed wide tail-like structure, with a measured-R-Af= 162 10-cm in an aperture radius = 104 km. The (V---R) colour and the reddening values depict a scenario of a slightly red dust coma. A dust mass-loss rate of--= 133 kg-s-1 is derived ...

2011-01-01

75

Standardization of rules for manufacturing normal electrical equipment for mining  

Energy Technology Data Exchange (ETDEWEB)

Information is provided about standardization and unification of rules for manufacturing normal electrical equipment designed for operating in underground shafts when there is no danger of explosion of gas, dust or steam. An analysis is made of the requirements included in the CEMA standard and in the state standard.

1983-01-01

76

Observations of late-type young stars in the Rho Oph dark cloud  

Energy Technology Data Exchange (ETDEWEB)

We present photoelectric BVRI photometry for 16 T Tau and related stars in the Rho Oph dark cloud, as well as vidicon spectroscopic observations for nine stars. The color excesses of these stars favor circumstellar dust shells as the source of the observed infrared excesses.

1980-04-01

77

Intergalactic dust and its photoelectric heating  

CERN Document Server

We have examined the dust photoelectric heating in the intergalactic medium (IGM). The heating rate in a typical radiation field of the IGM is represented by $\\Gamma_{\\rm pe} = 1.2\\times10^{-34}$ erg s$^{-1}$ cm$^{-3}$ $({\\cal D}/10^{-4})(n_{\\rm H}/10^{-5} {\\rm cm^{-3}})^{4/3} (J_{\\rm L}/10^{-21} {\\rm erg s^{-1} cm^{-2} Hz^{-1} sr^{-1}})^{2/3} (T/10^4 {\\rm K})^{-1/6}$, where ${\\cal D}$ is the dust-to-gas mass ratio, $n_{\\rm H}$ is the hydrogen number density, $J_{\\rm L}$ is the mean intensity at the hydrogen Lyman limit of the background radiation, and $T$ is the gas temperature, if we assume the new X-ray photoelectric yield model by Weingartner et al. (2006) and the dust size distribution in the Milky Way by Mathis, Rumpl, & Nordsieck (1977). This heating rate dominates the HI and HeII photoionization heating rates when the hydrogen number density is less than $\\sim10^{-6}$ cm$^{-3}$ if ${\\cal ...

2008-01-01

78

IgE antibodies to D. pteronyssinus in atopic patients.  

UK PubMed Central (United Kingdom)

An aqueous house dust mite extract was separated by SDS-PAGE and transferred to nitrocellulose membranes by Western Blotting. Two major allergens, Der pI and Der pII associated with the mite faeces...Full Text Available

1988-06-01

79

Exposure of cotton workers in an experimental cardroom with reference to airborne endotoxins.  

UK PubMed Central (United Kingdom)

Workers from cotton mills were exposed to cotton dust during carding in an experimental cardroom. Cotton from different geographical locations with varying amounts of endotoxin were used. Exposure levels...Full Text Available

1986-04-01

80

Development of a Coke-Free Cupola Furnace. Energy Conserving Shaft Furnace for Iron Materials. Final Report.  

Science.gov (United States)

Coke-fired cupola furnaces were improved and made suitable for the production of high-quality casting melts by numerous additional devices. Moreover, they were equipped with environmental protection systems with numerous dust separation devices and afterb...

1986-01-01

81

Deaths and tumours among workers grinding stainless steel: a follow up.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To study cause specific mortality and cancer morbidity in workers exposed to the dust of grinding materials, grinding agents, and stainless steel, especially with regard to a possibly increased...Full Text Available

1997-11-01

82

APOD: 2011 January 25 - The Rippled Red Ribbons of SNR 0509  

Science.gov (United States)

blast should have passed the Earth? Like: Follow APOD on Facebook Tomorrow's picture: whirlpool dust < | Archive | Index | Search | Calendar | RSS | Education | About APOD |...

2011-10-07

83

Tidd experience prepares hot gas cleaning technology for commercialization  

Energy Technology Data Exchange (ETDEWEB)

Pressurized fluidized bed combustion (PFBC) is an emerging coal-fired, combined-cycle power generation technology nearing commercial status through several operating and planned demonstration plants throughout the world. Current-generation PFBC plants use ``ruggedized`` gas turbines that can tolerate dust loading common with conventional cyclone gas cleaning. The next generation of PFBC will apply advanced hot gas cleaning systems that will reuse the dust loading to low levels acceptable to high performance, industrial gas turbines. These advances should result in performance and cost advantages. This article examines the demonstration of PFBC technology at Tidd power station.

1995-09-01

84

Thermal treatment of dusts from non ferrous metallurgical industries  

Energy Technology Data Exchange (ETDEWEB)

Three samples of dusts generated by the non ferrous metallurgical industries are treated between 200 and 800 degree centigree in controlled oxidizing and reducing atmospheres. The objective of this study is to recover the valuable metals from these wastes. The treatments of these solids under oxidizing conditions at 700 degree centigree are well adapted for two samples. The totality of valuable elements are concentrated in the treatments residues. The use of hydrogen at 600 degree centigree, permits the removal of up to 100 % of valuable metals contained in the treated industrial wastes. The recovery rate of valuable metals (Pb, Zn, Cu) as well as the Global Decontamination Factor are reported. (Author) 9 refs.

2000-07-01

85

Metastable carbon in two chondritic porous interplanetary dust particles  

International Nuclear Information System (INIS)

An analytical electron microscope study is presented on carbonaceous material in two chondritic porous aggregates, W7029* A and W7010* A2, from the Johnson Space Center Cosmic Dust Collection. The finding of well-ordered carbon-2H (lonsdaleite) in the two aggregates suggests that a record of hydrocarbon carbonization may be preserved in these materials. This carbon is a metastable phase resulting from hydrous pyrolysis below 300-350"0C and may be a precursor to poorly graphitized carbons in primitive extra terrestrial materials. (UK).

86

Kinetics of reduction of iron oxides using microwaves as power source  

Energy Technology Data Exchange (ETDEWEB)

This work deals with kinetic description of carbothermic reduction of iron oxides using microwaves as power source. Previous researches show that it is possible to conduct this kind of process successfully, but real kinetic comparisons between conventional and microwaves procedure have been presented partially. The aim of this work is to describe reduction kinetics, taking into account how the iron oxide is reduced by microwaves compared with conventional energy supply. In this study the authors used iron ore in pellet shape and dust. They found that both, pellet and dust reduction stops when it reaches approximately 40%, even at whole power.

1996-12-31

87

Asbestos: Industrial applications and precautions. (Latest citations from Information Services in Mechanical Engineering data base). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the properties, industrial uses and federal regulation of asbestos. The references explore advantages and disadvantages associated with use of industrial robots in areas containing high concentrations of asbestos dust, the use of water as a cutting tool to control the generation of asbestos dust, and governmental policies and attitudes relative to the health and welfare of workers subjected to asbestos. Thermal insulation properties, wear characteristics, high temperature capabilities, use as a reinforcement in composite materials, and asbestos substitutes are included. (Contains a minimum of 69 citations and includes a subject term index and title list.)

1992-07-01

88

A multi-wavelength scattered light analysis of the dust grain population in the GG Tau circumbinary ring  

Energy Technology Data Exchange (ETDEWEB)

We present the first 3.8 {micro}m image of the dusty ring surrounding the young binary system GG Tau, obtained with the W. M. Keck II 10m telescope's adaptive optics system. THis is the longest wavelength at which the ring has been detected in scattered light so far, allowing a multi-wavelength analysis of the scattering proiperties of the dust grains present in this protoplanetary disk in combination with previous, shorter wavelengths, HST images. We find that the scattering phase function of the dust grains in the disk is only weakly dependent on the wavelength. This is inconsistent with dust models inferred from observations of the interstellar medium or dense molecular clouds. In particular, the strongly forward-throwing scattering phase function observed at 3.8 {micro}m implies a significant increase in the population of large ({approx}> 1 {micro}m) grains, which provides direct evidence for grain ...

2004-02-04

89

Wind tunnel tests of biodegradable fugitive dust suppressants being considered to reduce soil erosion by wind at radioactive waste construction sites  

International Nuclear Information System (INIS)

Wind tunnel tests were performed of three fugitive dust control agents derived from potato and sugar beet products. These materials are being considered for use as dust suppressants to reduce the potential for transport of radioactive materials by wind from radioactive waste construction and remediation sites. Soil and dust control agent type, solution concentrations, application quantities, aging (or drying) conditions, surface disturbance, and wind and saltating sand eolian erosive stresses were selected and controlled to simulate application and exposure of excavated soil surfaces in the field. A description of the tests, results, conclusions, and recommendations are presented in this report. The results of this study indicate that all three dust control agents can protect exposed soil surfaces from extreme eolian stresses. It is also clear that the interaction and performance of each agent with ...

1993-01-01

90

Investigation of techniques to improve continuous air monitors under conditions of high dust loading in environmental setting. 1998 annual progress report  

Energy Technology Data Exchange (ETDEWEB)

'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and 1.0 \\265m Corning FNMB filters. ...

1998-06-01

91

3D Time-Dependent Model Of The Dusty-Gas Atmosphere Of Comet 67P/Churyumov-Gerasimenko: Recent Improvements.  

Science.gov (United States)

Under support from the French Space Agency (CNES), a 3D+t dusty-gas model of Comet 67P/Churyumov-Gerasimenko is being developed, to compute, from the first 2014 Rosetta orbital data, the aerodynamic forces exerted on the Rosetta orbiter and on the descent lander. We report the recently developed dust dynamics part of the code. The multi-species (presently H2O and CO) gas code is optimized in terms of computational speed owing to the use of two complementary methods: (a) 3D+t Direct Simulation Monte Carlo (DSMC) runs in the non-equilibrium regions adjacent to the surface and very distant from it, and (b) solutions of the Navier-Stokes equations in-between. The model is used presently using Lamy et al. (Space Sci. Rev., 2007, 128, 23) coarse information on 67P nucleus shape and rotation, and a range of possible gas production rates Q for the early Rosetta observations at rh 3 AU (Q 1026 - 1027 s-1). In the interim version, simplifying assumptions are made with ...

2010-10-01

92

A theoretical evaluation of solar-powered desiccant cooling in the United Kingdom  

Energy Technology Data Exchange (ETDEWEB)

Desiccant cooling is a potentially environmentally friendly technology that can be used to condition the internal environment of buildings. Unlike conventional air conditioning systems, which rely on electrical energy to drive the cooling cycle, desiccant cooling is a heat-driven cycle. This paper follows on from an initial study by the authors, and uses real meteorological data to evaluate the potential in the United Kingdom of using solar energy to drive the desiccant cooling cycle. Through the use of parametric studies, the paper investigates the energy consumption and costs associated with desiccant cooling. (author)

1999-07-01

93

DESIGN OF A CONVECTIVE COOLING SYSTEM FOR A MACH 6 - NASA ...  

Science.gov (United States)

Figure 23 presented detailed layout of the cooling system designed for the Mach 6 hypersonic- transport. The distribution system consisted of thin-wall ...

94

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the ...

1983-08-26

95

Theoretical investigations on improving performance of cooling systems for fuel cell vehicles; Theoretische Untersuchungen zur Kuehlleistungssteigerung durch innovative Kuehlsysteme fuer Brennstoffzellen-Elektrofahrzeuge  

Energy Technology Data Exchange (ETDEWEB)

In this work theoretical investigations are carried out for cooling systems, which are used in fuel cell vehicles. This work focuses mainly on the capability of increasing the heat rejection rate by using new alternative cooling systems and by improving the conventional cooling system. Fuel cell vehicles have a higher demand of heat rejection to the ambient than comparable vehicles with combustion engine. The performance of conventional liquid cooling systems, especially at high loads and high ambient temperatures, is often not sufficient anymore. Hence, cooling systems with improved performance are necessary for fuel cell vehicles. The investigations in this work are based on DaimlerChrysler's ''A-Class'' having a PEM-Fuel Cell system integrated. Specific computational models are developed for radiators and condensers to evaluate the ...

2008-04-01

97

Fast cooling of steam turbines. Schnellabkuehlen von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).

1987-01-01

98

Chalk Point Cooling Tower Project. Volume 2. Cooling Tower Drift Dye Tracer Experiment, June 16 and 17, 1977.  

Science.gov (United States)

A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aero...

1977-01-01

100

Achieving more reliable operation of turbine generators at nuclear power plants by improving the water chemistry of the generator stator cooling system  

British Library Electronic Table of Contents (United Kingdom)

Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.

2011-01-01

101

Observation of Spontaneous Brillouin Cooling  

CERN Document Server

While radiation-pressure cooling is well known, the Brillouin scattering of light from sound is considered an acousto-optical amplification-only process. It was suggested that cooling could be possible in multi-resonance Brillouin systems when phonons experience lower damping than light. However, this regime was not accessible in traditional Brillouin systems since backscattering enforces high acoustical frequencies associated with high mechanical damping. Recently, forward Brillouin scattering in microcavities has allowed access to low-frequency acoustical modes where mechanical dissipation is lower than optical dissipation, in accordance with the requirements for cooling. Here we experimentally demonstrate cooling via such a forward Brillouin process in a microresonator. We show two regimes of operation for the Brillouin process: acoustical amplification as is traditional, but also for the first time, ...

2011-01-01

102

Aerosol Physical, Optical and Chemical Properties during African Dust Events at Cape San Juan (CPR)  

Science.gov (United States)

Large amounts of atmospheric dust are lifted from the North African deserts and are transported by the trade winds over the Caribbean region, especially during the summer months. How African dust particles influence the earth's radiative budget is not well understood because these particles are highly variable and their physical, optical, and chemical properties are poorly characterized, especially when they are atmospherically processed as are those that travel from Africa to the Caribbean region. Here we present results of aerosol measurements performed at Cape San Juan (CPR), a ground-based station located at the northeastern tip of the Caribbean island of Puerto Rico. We used a condensation particle counter to determine the particle number concentration, a sunphotometer (part of the AErosol RObotical NETwork, AERONET, aeronet.gsfc.nasa.gov) to determine volume size distributions and aerosol optical thickness, and a 3-wavelength ...

2008-12-01

103

Economic evaluation of four types of dry/wet cooling applied to the 5-MWe Raft River geothermal power plant  

Energy Technology Data Exchange (ETDEWEB)

A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had ...

1982-07-01

104

HANARO cooling features: design and experience  

International Nuclear Information System (INIS)

In order to achieve the safe core cooling during normal operation and upset conditions, HANARO adopted an upward forced convection cooling system with dual containment arrangements instead of the forced downward flow system popularly used in the majority of forced convection cooling research reactors. This kind of upward flow system was selected by comparing the relative merits of upward and downward flow systems from various points of view such as safety, performance, maintenance. However, several operational matters which were not regarded as serious at design come out during operation. In this paper are presented the design and operational experiences on the unique cooling features of HANARO. (author)

1999-08-01

105

Closed loop air cooling system for combustion turbines  

Energy Technology Data Exchange (ETDEWEB)

Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts.

1998-01-01

106

Stellar and Dust Properties of Local Elliptical Galaxies: Clues to the Onset of Nuclear Activity  

CERN Document Server

We study the stellar and dust properties of a well-defined sample of local elliptical galaxies to investigate the relationship between host galaxy properties and nuclear activity. We select a complete sample of 45 ellipticals from the Palomar spectroscopic survey of nearby galaxies, which includes 20 low-luminosity active galactic nuclei classified as LINERs and 25 inactive galaxies. Using a stellar population synthesis method, we compare the derived stellar population properties of the LINER versus the inactive subsamples. We also study the dust and stellar surface brightness distributions of the central regions of these galaxies using high-resolution images obtained with the {\\it Hubble Space Telescope}. Relative to the inactive subsample, ellipticals hosting LINERs share similar total optical and near-infrared luminosity, central stellar velocity dispersions, and nuclear stellar populations as judged from their luminosity-weighted ages and ...

2008-01-01

107

Standards for limits of air pollutant emission in the GDR  

Energy Technology Data Exchange (ETDEWEB)

Activities of the Referenzlaboratorium Reinhaltung der Luft at Magdeburg as well as existing air pollution standards in the German Democratic Republic are reviewed. The laboratroy coordinates research and standardization in the field of industrial air pollution for the Ministry of Health. The standards provide orientation for emission control by state district health inspectorates. Emission limits (in g/m/sup 3/) which are international standards for 15 selected industries are listed. Emission limits (in g/m/sup 3/) of GDR standards, issued between 1971 and 1984 are also provided. They concern emission of brown coal dust from coal preparation plants, dust and chemical compound emission from metallurgical plants, dust emission from plants of the limestone and cement industry as well as from cupola furnace plants, boiler plants, plants of the wood industry and road asphalt mixing. Six additional standards which entered effect ...

1986-01-01

108

Management of storage rot in onion through gamma irradiation and chemicals  

International Nuclear Information System (INIS)

Pre-harvest sprays of bavistin (50% carbendazim) at 100, 200 and 400 g a.i/ha were ineffective in the control of Aspergillus niger van Tieghem in onion. The combination of gamma irradiation (0.1 kGy) with bavistin dust (0.33g a.i/kg bulbs) was effective to an extent of about 79% in reducing storage losses due to sprouting and rottage. This combination treatment was better than dust treatment alone and highly cost effective. Bavistin, when used as pre-harvest spray, did not leave any residue in the tissues, whereas the compound was seen to move deep into the tissues, when used as post-harvest dust treatment. Higher concentrations of carbendazim residues (2.1-3.4 mg/kg bulb) were detected in the outer scales of the bulbs, as compared to that of inner scales (0.6-1.6 mg/kg), and the residue decreased slightly with passage of storage time. (author). 19 refs., 2 tabs.

109

Injection of recyclable byproducts into a cupola furnace via natural gas/O{sub 2} burners; Einblasen von wiederverwertbaren Reststoffen ueber Erdgas/O{sub 2}-Brenner in einen Kupolofen  

Energy Technology Data Exchange (ETDEWEB)

Disposal of fine-particled byproducts via injection into a capola furnace using natural gas/O{sub 2} burners is a cost-efficient alternative to landfill dumping. Tests conducted in a foundry demonstrated that dusts collected there can be injected without detriment to melt-down rate and iron quality. The replacement of FeSi pellets with FeSi dust in addition reduced the slag content, while injection of coal dust permitted a decrease in coke consumption. (orig.) [Deutsch] Die Entsorgung von feinkoernigen Reststoffen durch Einblasen in einen Kupolofen ueber Erdgas/O{sub 2}-Brenner ist eine wirtschaftliche Alternative zur Deponierung. Anhand von Versuchen in einer Giesserei konnte aufgezeigt werden, dass hier anfallende Staeube ohne nachteilige Auswirkungen auf Schmelzleistung und Eisenqualitaet einzublasen sind. Die Substitution von FeSi-Formlingen durch FeSi-Staub brachte zudem eine Reduzierung des Schlackeanteils und das ...

1997-07-01

110

H_2 emission arises outside photodissociation regions in ultra-luminous infrared galaxies  

CERN Document Server

Ultra-luminous infrared galaxies are among the most luminous objects in the local universe and are thought to be powered by intense star formation. It has been shown that in these objects the rotational spectral lines of molecular hydrogen observed at mid-infrared wavelengths are not affected by dust obscuration, leaving unresolved the source of excitation of this emission. Here I report an analysis of archival Spitzer Space Telescope data on ultra-luminous infrared galaxies and demonstrate that star formation regions are buried inside optically thick clouds of gas and dust, so that dust obscuration affects star-formation indicators but not molecular hydrogen. I thereby establish that the emission of H_2 is not co-spatial with the buried starburst activity and originates outside the obscured regions. This is rather surprising in light of the standard view that H_2 emission is directly associated with star-formation ...

2010-01-01

111

Episodic mass loss in binary evolution to the Wolf-Rayet phase: Keck and HST proper motions of RY Scuti's nebula  

CERN Document Server

Binary mass transfer via Roche-lobe overflow (RLOF) is a key channel for producing stripped-envelope Wolf-Rayet (WR) stars and may be critical to account for SN Ib/c progenitors. RY Scuti is an extremely rare example of a massive binary star caught in this brief but important phase. Its toroidal nebula indicates equatorial mass loss during RLOF, while the mass-gaining star is apparently embedded in an opaque accretion disk. RY Scuti's toroidal nebula has two components: an inner ionised double-ring system, and an outer dust torus that is twice the size of the ionised rings. We present two epochs of Lband Keck NGS-AO images of the dust torus, plus three epochs of HST images of the ionised gas rings. Proper motions show that the inner ionised rings and the outer dust torus came from two separate ejection events roughly 130 and 250 yr ago. This suggests that RLOF in massive contact binaries can be accompanied by eruptive and ...

2011-01-01

112

Combined Scanning Electron Microscope and Micro-InfraRed measurements on Interplanetary Dust Particles  

CERN Document Server

Laboratory characterization of Interplanetary Dust Particles (IDPs) collected in the lower stratosphere represents a concrete analysis of cosmic dust properties which played a fundamental role in the origin and evolution of Solar System. The IDPs were characterized by Field Emission Scanning Electron Microscope (FESEM) analyses and by InfraRed (IR) micro-spectroscopy. We present the FESEM images of six IDPs: three smooth grains, two porous and one a compact sphere. We also show the results of micro-IR transmission measurements on four IDPs that allowed us to identify their spectral class according to the criteria defined by Sandford and Walker. Only three of the analyzed particles show IR transmission spectra with a dominant "silicate absorption feature" so that they could be assigned to the three IR spectral classes: one has been classified as "amorphous olivine", one appears to be a mixture of "olivines" and "pyroxenes" and one belongs to the ...

2007-01-01

113

Briquetting of self-reducing blendings of waste iron oxide mixtures. Final report  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this project were to develop technologies to manufacture self-reducing briquettes out of waste iron oxides and to recycle them in an electric arc furnace or a cupola furnace. CRM has investigated and determined the optimal characteristics (binder, size, grain size, compositions and activator for the reduction reaction) for briquettes containing mixtures of mill scales, mill sludges, electric arc furnace (EAF) dust and coal as reduction agent. The goal of obtaining briquettes, in which iron oxides are totally reduced when these briquettes are loaded with the scrap into an electric arc furnace, was achieved. Trials at ProfilARBED have shown that it is possible to recycle mill and EAF by-products conditioned in self-reducing briquettes in an electric arc furnace without influence on the performance and on the environment. The iron content of the slag does not increase as the iron of the by-product is almost completely reduced. Zinc is completely ...

2002-07-01

114

RADIAL DISTRIBUTION OF STARS, GAS AND DUST IN SINGS GALAXIES. I. SURFACE PHOTOMETRY AND MORPHOLOGY  

International Nuclear Information System (INIS)

We present ultraviolet through far-infrared (FIR) surface brightness profiles for the 75 galaxies in the Spitzer Infrared Nearby Galaxies Survey (SINGS). The imagery used to measure the profiles includes Galaxy Evolution Explorer UV data, optical images from Kitt Peak National Observatory, Cerro Tololo Inter-American Observatory, and Sloan Digital Sky Survey, near-IR data from Two Micron All Sky Survey, and mid- and FIR images from Spitzer. Along with the radial profiles, we also provide multi-wavelength asymptotic magnitudes and several nonparametric indicators of galaxy morphology: the concentration index (C 42), the asymmetry (A), the Gini coefficient (G), and the normalized second-order moment of the brightest 20% of the galaxy's flux (M-bar20). In this paper, the first of a series, we describe the technical aspects regarding the surface photometry, and present a basic analysis of the global and structural properties of the SINGS galaxies at different wavelengths. The homogeneity ...

2009-10-01

115

Tar removal with a wet ElectroStatic Precipitator (ESP). A parametric study  

Energy Technology Data Exchange (ETDEWEB)

The ElectroStatic Precipitator (ESP) removes dust and tar droplets very efficiently from biomass product gas. Dust was removed for more than 99%. The tar dewpoint was reduced from 130C to 21C, which is sufficient for the application of the product gas in a gas engine. Tar removal is not sensitive to the voltage or fluctuations in the gas residence time . The voltage was varied between 28 to 37 kV{sub arith} and the gas residence time between 4 and 11s. Fouling of the ESP collector plates was negligible, which was concluded from visual inspection after 200 hours of operation. A reduction in the residence time reduces the size of the ESP and has a significant impact on the investment costs of the ESP. Keywords: electrostatic filter, tar removal, circulating fluidised bed (CFB)

2004-05-01

116

Problematic of atmospheric pollution in Lebanon: the better stake is apprehended, the best acts are taken  

International Nuclear Information System (INIS)

The document presents an overview on atmospheric pollution in Lebanon, with an analysis of sources of pollution, their impact on local and global environment and their control.Local causes of pollution are mainly: -Thermal power plants of electric power production which produce 75% SO_2 emission and 60% dust - Industries, especially cement industry - Land transportation which produces 70% NOX emission and 50% CO_2 A description of air pollution caused by these three sectors is revealed. Pollutants derived from fuel combustion are analyzed. It is estimated that in 2010, Co_2 emission will reach 5204450 tons, SO_2 emission will be 136470 tons, NOX emissions 96870 and dust estimated to 4130 tons. CFC consumption and measures of control according to Montreal Protocol are described. Recommendations for control of air pollution in Lebanon within a national policy are presented.

117

In-depth survey report of Scoular Elevator, Salina, Kansas  

Science.gov (United States)

An in/depth industrial hygiene survey of exposures to phosphine during the use of aluminum phosphide was conducted as part of a survey on exposure to grain fumigants. Area monitoring and breathing-zone sampling for phosphine were conducted during the addition of aluminum phosphide to grain during turning operations; source samples and peak personal exposures were also analyzed. Major sources of personal exposure included the escape of air from the bin headspace during filling with treated grain, filling and emptying of the phosphide pellet dispenser, and infiltration from the treated grain bin and from the pellet dispenser itself into adjacent air space. Relatively good dust control was indicated by the total dust samples collected during the survey. Measures recommended by the author are in the report.

1987-06-01

118

Homoclinic chaos and energy condition violation  

International Nuclear Information System (INIS)

In this letter we discuss the connection between so-called homoclinic chaos and the violation of energy conditions in locally rotationally symmetric Bianchi type IX models, where the matter is assumed to be nontilted dust and a positive cosmological constant. We show that homoclinic chaos in these models is an artifact of unphysical assumptions: it requires that there exist solutions with positive matter energy density #rho#>0 that evolve through the singularity and beyond as solutions with negative matter energy density #rho#<0. Homoclinic chaos is absent when it is assumed that the dust particles always retain their positive mass. In addition, we discuss more general models: for solutions that are not locally rotationally symmetric we demonstrate that the construction of extensions through the singularity, which is required for homoclinic chaos, is not possible in general.

2006-09-15

119

Use of a temperature-initiated passive cooling system (TIPACS) for the modular high-temperature gas-cooled reactor cavity cooling system (RCCS)  

Energy Technology Data Exchange (ETDEWEB)

A new type of passive cooling system has been invented (Forsberg 1993): the Temperature-Initiated Passive Cooling System (TIPACS). The characteristics of the TIPACS potentially match requirements for an improved reactor-cavity-cooling system (RCCS) for the modular high-temperature gas-cooled reactor (MHTGR). This report is an initial evaluation of the TIPACS for the MHTGR with a Rankines (steam) power conversion cycle. Limited evaluations were made of applying the TIPACS to MHTGRs with reactor pressure vessel temperatures up to 450 C. These temperatures may occur in designs of Brayton cycle (gas turbine) and process heat MHTGRs. The report is structured as follows. Section 2 describes the containment cooling issues associated with the MHTGR and the requirements for such a cooling system. Section 3 describes TIPACS in nonmathematical terms. Section 4 describes ...

1994-04-01

120

User's guide for the BNW-III optimization code for modular dry/wet-cooled power plants  

Energy Technology Data Exchange (ETDEWEB)

This user's guide describes BNW-III, a computer code developed by the Pacific Northwest Laboratory (PNL) as part of the Dry Cooling Enhancement Program sponsored by the US Department of Energy (DOE). The BNW-III code models a modular dry/wet cooling system for a nuclear or fossil fuel power plant. The purpose of this guide is to give the code user a brief description of what the BNW-III code is and how to use it. It describes the cooling system being modeled and the various models used. A detailed description of code input and code output is also included. The BNW-III code was developed to analyze a specific cooling system layout. However, there is a large degree of freedom in the type of cooling modules that can be selected and in the performance of those modules. The costs of the modules are input to the code, giving the user a great deal of flexibility.

1984-09-01

121

Spectroscopy of a narrow-line laser cooling transition in atomic dysprosium  

CERN Document Server

The laser cooling and trapping of ultracold neutral dysprosium has been recently demonstrated using the broad, open 421-nm cycling transition. Narrow-line magneto-optical trapping of Dy on longer wavelength transitions would enable the preparation of ultracold Dy samples suitable for loading optical dipole traps and subsequent evaporative cooling. We have identified the closed 741-nm cycling transition as a candidate for the narrow-line cooling of Dy. We present experimental data on the isotope shifts, the hyperfine constants A and B, and the decay rate of the 741-nm transition. In addition, we report a measurement of the 421-nm transition's linewidth, which agrees with previous measurements. We summarize the laser cooling characteristics of these transitions as well as other narrow cycling transitions that may prove useful for cooling Dy.

2010-01-01

122

Full-scale model of cooling and heating system for JT-60 vacuum vessel  

Science.gov (United States)

A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature regulation.

1981-01-01

123

Control of quench distortion for steel parts  

Energy Technology Data Exchange (ETDEWEB)

There are two types in quench distortion of steel parts: thermal distortion and transformation distortion. Quench distortion is caused mainly by uneven cooling rate of steel parts from Austenitising temperature. The rapid cooled side is lengthened (convex deformation); the slow cooled side is shortened (concave deformation). So, to control the quench distortion, it is necessary to regulate the cooling rate of steel parts during quenching. TWO COMPONENTS produce the quench distortion of steel parts: the thermal stress and transformation stress. Generally, the effect of the thermal stress on the quench distortion is stronger than the transformation stress. The quench distortion is caused by uneven cooling rate of the steel parts, from Austenitising temperature to Ms point and Ms-Mf range. So, to control the quench distortion, it is very important to regulate the ...

1996-12-31

124

Control of cooling during spray forming of bearing steel billets  

Energy Technology Data Exchange (ETDEWEB)

In an effort to minimize the distortion of bearing steel rings during the production process, 100Cr6 steel billets are spray formed with a unique cooling control system to control the cooling and solidification behavior of the deposits. Effects of heating around the deposits, gas cooling at the substrate bottom and the gas flow over the deposits are investigated both by numerical simulation and experiment. Porosity profiles and microstructures of spray formed bearing steel are examined and evaluated. The investigation results show that the thermal boundary conditions of the deposits play important roles on the cooling and solidification behavior of the deposits, especially at the deposit periphery. Porosity in the 100Cr6 bearing steel deposit can be reduced significantly with the special cooling control system.

2004-10-10

125

Chalk Point cooling tower project. Volume 2. Cooling tower drift dye tracer experiment, June 16 and 17, 1977. Final report 1 July 1976--30 June 1977  

Science.gov (United States)

A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aerosol deposition from other sources and to provide a data base for use in cooling tower salt loading and model validation. Prior to the experiment, laboratory tests showed that Rhodamine (WT) was inexpensive, safe and controllable when used as a drift dye tracer. Positive identification and separation of cooling tower drift can be made among other sources using a dye tracer.

1977-08-01

126

A Single Laser System for Ground State Cooling of 25-Mg+  

CERN Document Server

We present a single solid-state laser system to cool, coherently manipulate and detect $^{25}$Mg$^+$ ions. Coherent manipulation is accomplished by coupling two hyperfine ground state levels using a pair of far-detuned Raman laser beams. Resonant light for Doppler cooling and detection is derived from the same laser source by means of an electro-optic modulator, generating a sideband which is resonant with the atomic transition. We demonstrate ground-state cooling of one of the vibrational modes of the ion in the trap using resolved-sideband cooling. The cooling performance is studied and discussed by observing the temporal evolution of Raman-stimulated sideband transitions. The setup is a major simplification over existing state-of-the-art systems, typically involving up to three separate laser sources.

2010-01-01

127

Waterjet-assisted cutting nears commercialization  

Energy Technology Data Exchange (ETDEWEB)

Water-assisted mining machinery is beginning to be considered in the US, although it has been in use in Europe for some time. A waterjet roof bolter is currently under test and should greatly increase drilling rate with longer bit life and no dust. Water-assisted roadheaders and longwall winning machines under development in Europe and the US are described.

1984-12-01

128

The method for iron removal from cadmium in the course of refining process; Sposob usuwania zelaza z kadmu w procesie jego rafinacji  

Energy Technology Data Exchange (ETDEWEB)

The pyrometallurgic method consisting in introduction of refining agent into the liquid cadmium has been presented. The refining agent consisting of silicon nitride, carbon dust and sodium hydroxide has been added in several portion into the liquid cadmium. Iron has been removed from the cadmium surface in the form of floating slag.

1992-10-30

129

The chemical properties of silica particle surface in relation to silica-cell interactions  

Energy Technology Data Exchange (ETDEWEB)

Although silicosis has been studied extensively, the mechanism is still not fully understood. Experiments do provide evidence that the actions of unique properties of silica surface on the cell membrane are the starting point of silicotic processes. This paper summarizes literature on chemical properties of silica surface, and the effect of particle size on silica toxicity. This paper also discusses the ways in which silica dusts are though to interact with the cell membrane, with emphasis on freshness, hydrogen bonding, and free-radical interactions.

1989-01-01

130

Surface photometry and the structure of elliptical galaxies  

International Nuclear Information System (INIS)

Surface photometry of bulges and elliptical galaxies is reviewed. The properties of cores and nuclei as revealed by improvements in seeing and the use of CCDs are examined, and newly discovered structural details such as dust, shells, and dynamical subsystems which show the importance of accretion events in galactic evolution are addressed. Improved constraints on galaxy formation resulting from better measurements of parameter scaling laws are discussed, and accurate measurements of departures from elliptical isophotes and of color gradients obtained with CCDs are considered.

131

Silica, silicosis and tuberculosis.  

Science.gov (United States)

Exposure to crystalline silica dust causes multiple diseases, but silicosis and silica dust-associated tuberculosis (TB), in particular, are the two diseases that remain high on the list of occupational health priorities in low-income countries and that still occur in some high-income countries. The prevalence of silica-related TB is exacerbated by the human immunodeficiency virus (HIV) epidemic in low-income countries. This review describes the morphology of silica and the variable potency of the different forms. Sources of crystalline silica are discussed, with emphasis on less commonly recognised sources, such as small-scale mining operations and agriculture. Trends in the prevalence of silicosis are also presented. Although efforts have been made for many years in most countries to reduce silica dust levels, silicosis continues to occur even in young people. The clinical and pathological features and diagnosis of ...

2007-05-01

132

Shale oil explosives  

Energy Technology Data Exchange (ETDEWEB)

Ammonium nitrate shale oil explosives are provided which are effective, powerful, inexpensive, and safe. The explosives contain about 2% to 10% by weight shale oil and about 90% to 98% by weight ammonium nitrate. The shale oil can be whole shale oil or heavy shale oil containing from 0.1% to 65% by weight oil shale dust. The ammonium nitrate is preferably in the form of explosive grade ammonium nitrate prills.

1984-10-09

133

Polycyclic aromatic hydrocarbon emission profiles and removal efficiency by electrostatic precipitator and wetfine scrubber in an iron ore sintering plant  

Energy Technology Data Exchange (ETDEWEB)

A monitoring campaign of polychlorinated dibenzo-p-dioxins and dibenzofurans, polyaromatic hydrocarbons (PAHs), and polychlorinated biphenyl was carried out in an Italian iron ore sintering plant by sampling the combustion gases at the electrostatic precipitator (ESP) outlet, at the Wetfine scrubber (WS) outlet, and by collecting the ESP dust. Few data are available on these micropollutants produced in iron ore sintering plants, particularly from Italian plants. This study investigates the PAH emission profiles and the removal efficiency of ESPs and WS. PAHs were determined at the stack, ESP outlet flue gases, and in ESP dust to characterize the emission profiles and the performance of the ESP and the WS for reducing PAH emission. The 11 PAHs monitored are listed in the Italian legislative decree 152/2006. The mean total PAH sum concentration in the stack flue gases is 3.96 {mu}g/N m{sup 3}, in ESP outlet flue gases is 9.73 {mu}g/N m{sup 3}, ...

2008-11-15

134

Metabolomics in Lung Inflammation: A High Resolution 1H NMR Study of Mice Exposed to Silica Dust  

UK PubMed Central (United Kingdom)

Here we report the first 1H NMR metabolomics studies on excised lungs and bronchoalveolar lavage fluid (BALF) from mice exposed to crystalline silica. High resolution 1H...Full Text Available

2008-01-01

135

ELECTRON MICROSCOPE PREPARATIONS OF RADIOACTIVELY LABELED AEROSOLS  

Science.gov (United States)

A method is described to smear extremely thin layers of nuclear emulsion on labeled electron microscope preparations and to measure the thicknesses of these layers, Without further separation, preparation and emulsion can be observed after exposure and development in an electron microscope. The source of the tracks formed in the emulsion can be exactly identified and the size and structure determined. This method finds applications in dust research and also in the analysis of medical and biological sections. Further information can be obtained about properties of different emulsions. (auth)

1963-04-01

136

An Investigation of the Coastal Circulations and Aerosol Transport in the Arabian Gulf region during Unified Aerosol Experiment (2004)  

Science.gov (United States)

An observational and modeling study was performed over the Arabian Gulf region to investigate the coastal circulations and aerosol transport in the area. Climatological data and observations from the United Arab Emirates' Unified Aerosol Experiment were used to develop a better understanding of the complex meteorological processes in the Arabian Gulf region. Climatological data suggests that sea breezes occur on more than 77 percent of days in all months of the year and land breezes occur on more than 70 percent of the days. The occurrence of the sea and land breeze circulations are higher (90-99 percent) during the summer months when large-scale weather patterns are quiescent. Measurements of aerosol concentrations taken during the Unified Aerosol Experiment(2004) experiment are used to investigate aerosols, namely dust, transported in the Arabian Gulf region. Vertical profiles of dust concentration along with vertical profiles of potential ...

2005-12-01

137

An ADP proposal to study the formation and evolution of dust-embedded clusters. Final report  

International Nuclear Information System (INIS)

Using high resolution and high sensitivity IRAS data at 12 and 25 microns low mass stars were studied which have recently formed in the Ophiuchus, Corona Australis, and IC1396 dark clouds. The successful application of these techniques to the Rho Ophiuchi infrared cluster is briefly described. The status of research performed is also presented.

138

APERTURE SYNTHESIS IMAGING OF V892 Tau AND PV Cep: DISK EVOLUTION  

International Nuclear Information System (INIS)

I present a study of two Herbig Ae stars that are in completely different evolutionary stages: V892 Tau and PV Cep. Using sub-arcsecond interferometric observations obtained with the Combined Array for Research in Millimeter-wave Astronomy at #lambda# = 1.3 and 2.7 mm, I have for the first time resolved their disks. I deduce that the 5 Myr old V892 Tau has a low dust opacity index #beta# = 1.1 and a disk mass of #approx#0.03 M_s_u_n. These values correspond to the growth of its dust into large, up to centimeters size, structures. In contrast, the very young (a few x10"5 yr) PV Cep has a quite high opacity index #beta# = 1.75 and a more massive disk 0.8 M_s_u_n. PV Cep has the youngest resolved disk around any Herbig Ae star. Unlike the youngest T Tauri and Class 0 stars, which contain large and processed grains, the young Herbig Ae star, PV Cep, disk contains interstellar-medium-like unprocessed dust. This suggests that PV ...

2010-10-10

139

User's manual for the BNW-I optimization code for dry-cooled power plants. [MFCIRI Code  

Science.gov (United States)

This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)

1977-01-01

140

Roof slab cooling device in a FBR type reactor  

International Nuclear Information System (INIS)

Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power ...

1986-05-16

141

RF tumor ablation with internally cooled electrodes and saline infusion: what is the optimal location of the saline infusion?  

UK PubMed Central (United Kingdom)

BackgroundRadiofrequency ablation (RFA) of tumors by means of internally cooled electrodes (ICE) combined with interstitial infusion of saline may improve clinical results. To date,...Full Text Available

142

Quality assurance requirements for packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants (Revision 1) - October 1976  

International Nuclear Information System (INIS)

This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.

143

Quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems  

International Nuclear Information System (INIS)

The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.

144

Legionella fairfieldensis sp. nov. isolated from cooling tower waters in Australia.  

UK PubMed Central (United Kingdom)

Three Legionella-like organisms were isolated from water from the cooling towers of two Australian institutions. The strains grew on buffered charcoal-yeast extract (BCYE) agar but not on BCYE agar...Full Text Available

1991-03-01

145

Doublet III vacuum vessel neutral beam armor  

Science.gov (United States)

The evolution of the Doublet III neutral beam armor is followed from the initial design of a radiation cooled metallic tile to the present actively cooled graphite design. Results of the thermal and stress analyses that dictated the present design are reviewed.

1979-11-01

146

A comprehensive approach to cooling tower design  

Energy Technology Data Exchange (ETDEWEB)

In this paper, a mathematical model for a counterflow wet cooling tower is derived, which is based on one-dimensional heat and mass balance equations using the measured heat transfer coefficient. The balance equations are solved numerically to predict the temperature change of air and water, as well as the humidity as a function of the cooling tower high. Experimental measurements on two pilot-scale cooling towers were carried out in order to analyze the performance of different cooling tower filling materials. Also, the performance of other cooling tower elements, such as droplet separators and water spray nozzles, was investigated in the pilot experiments. The flow distribution, i.e. the velocity field, upstream to the filling material was predicted using the three-dimensional version of the computational fluid dynamics (CFD) code Fluent/UNS, version 4.2. The calculated flow ...

2001-06-01

147

A Multi-Method Process Evaluation for a Skin Cancer Prevention Diffusion Trial  

UK PubMed Central (United Kingdom)

This article describes process evaluation methods for the Pool Cool Diffusion Trial across four years. Pool Cool is a skin cancer prevention program that was...Full Text Available

2009-06-01

148
150

Natural convection cooling for offshore nuclear power plants  

International Nuclear Information System (INIS)

(May 1974). United States Klystra, CD Univ. of Florida, Gainesville v.

151

Natural convection cooling for offshore nuclear power plants  

International Nuclear Information System (INIS)

(1973). United States Kylstra, CD West Palm Beach, Florida, USA. 25 Apr 1973.

1973-04-25

152

MAY 1988. - NASA Technical Reports Server  

Science.gov (United States)

disciplinary methods were used to independently determine the aerodynamic loads, the thermal response, and strardural performance of the hydrogen cooled ...

153

MASER"'\\ - NASA Technical Report Server (NTRS)  

Science.gov (United States)

cooling system designed to reject waste heat producedwithin the alternatorand. To other equipment operatingat much lower tempera- ...

154

Integrated Reconfigurable Intelligent Systems (IRIS) for ...  

Science.gov (United States)

... They comprise of a power model for the representation of the electric system, a fluid model that represents the cooling fluid flow, three layers of ...

2009-10-31

155

Fuel cycle of reactor SVBR-100  

International Nuclear Information System (INIS)

... fast reactors fbr type reactors fuels liquid metal cooled reactors materials nuclear

156

Development of radial-flow type internally oil-cooled oil-filled cable  

Energy Technology Data Exchange (ETDEWEB)

A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.

1988-01-01

157

Behavior of the cooling towers as a function of the time  

International Nuclear Information System (INIS)

In the scope of the nuclear plants lifetime study, the behavior of the cooling towers is discussed. The main geometrical characteristics of the cooling towers in the French nuclear power plants, are presented. The surveyance program, the risks of accident, the research and development actions are considered. The results of the investigations of the cooling tower structure show that it is a multidiciplinary problem and needs the development of experimental and theoretical methods. Concerning the regenerators, the surveyance actions under operating conditions, the accelerated aging tests, and some aspects of the mechanical resistance, are underlined. It is shown that mainly the creep tests will allow the lifetime estimation of the materials developed for the regenerators.

1988-12-01

158

Advanced Gas Cooling Study for the Hospital at Davis ...  

Science.gov (United States)

... The performance at reduced condenser water temper- atures was assumed to be the same as that of the single-effect unit. ...

1999-01-01

159

Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.

1995-05-01

160

Natural Circulation Cooling Capability in the AHR  

International Nuclear Information System (INIS)

An AHR (Advanced HANARO Reactor) based on the HANARO has been conceptually developed for the future needs of research reactors. Generally, a natural convection cooling in nuclear installations is an ultimate heat removal mechanism as an inherent safety feature. This paper presents the preliminary thermal hydraulic characteristics and safety margins for a natural convection cooling in the AHR.

2007-10-01

161

Effect of cooling conditions during heat treatment on mechanical properties of titanium alloy VT3-1  

International Nuclear Information System (INIS)

Effect of cooling rates within the wide range (0.003-45 grad/s) on the complex of mechanical properties of (#alpha#-#beta#)-titanium alloy VT3-1 is studied in the process of heat treatment. Cooling conditions of semifinished product made of this alloy with a different structure providing optimum combination of strength, ductility fracture toughness, heat resistance, and endurance are determined.

162

Doublet III limiter/armor update  

Energy Technology Data Exchange (ETDEWEB)

The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.

1983-12-01

163

Desiccant cooling: parametric energy study  

Energy Technology Data Exchange (ETDEWEB)

Desiccants have been used in many applications to provide dehumidification. This paper describes an application of desiccants which provide both dehumidification and sensible cooling, with little or no use of conventional vapour-compression refrigeration plant. Through a parametric study, the energy consumption and costs of a desiccant cooling system are compared with those of a conventional vapour-compression refrigeration-based air-conditioning system. (author)

1998-12-31

164

Cooling of nuclear power stations with high temperature reactors and helium turbine cycles  

International Nuclear Information System (INIS)

On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable ...

165

Cooling device for rotors of multistage axial steam turbines  

International Nuclear Information System (INIS)

The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).

166

Chalk Point Cooling Tower Project. Environmental Systems Corporation's FY77 final report, July 1, 1976--August 31, 1977. Volume II. Cooling Tower Drift Dye Tracer Experiment. [Dye tests of vapor plume dispersion in coastal regions  

Science.gov (United States)

Results are reported from dye tests of the dispersion of the vapor plume from the natural draft cooling tower of a fossil-fuel power plant located in the coastal region of Maryland.

1977-12-01

167

A study of the importance of occupancy to building cooling load in prediction by intelligent approach  

International Nuclear Information System (INIS)

Research highlights: #-># The building occupancy affecting the cooling load prediction is studied. #-># PENN model is adopted in this study for predicting the building cooling load. #-># Statistical approach is adopted to result a less prejudice prediction performance. #-># Results show that occupancy data can significantly improve the prediction. -- Abstract: Building cooling load prediction is one of the key factors in the success of energy-saving measures. Many computational models available in the industry today have been developed from either forward or inverse modeling approaches. However, most of these models require extensive computer resources and involve lengthy computation. This paper discusses the use of data-driven intelligent approaches, a probabilistic entropy-based neural (PENN) model to predict the cooling load of a building. Although it is common knowledge that the presence ...

2011-07-01

168

Using Floor Cooling as an Approach to improve the Thermal Environment in the Sleeping Area in an Open Pig House  

British Library Electronic Table of Contents (United Kingdom)

In order to provide pigs a comfortable sleeping area in hot weather, a floor cooling system was designed and applied to production buildings. Experiments were conducted to compare the floor temperatures and to observe the lying behaviour of pigs in the sleeping area of the buildings with and without floor cooling system. The results showed that, without the floor cooling system, the floor temperature was nearly the same as the air temperature in the open pig house. With the floor cooling system, the floor temperature of the sleeping area was controlled at 22-26degreeC, even though the air temperature was as high as 34degreeC, which improved the comfort of the pigs in the sleeping area. The pig lying behaviour was greatly affected by the floor temperature. More than 85% of the pigs were lyi...

2006-01-01

169

Thermal-hydraulic performance of the GETR emergency cooling system: experimental and analytical considerations  

International Nuclear Information System (INIS)

The General Electric Test Reactor emergency cooling system performance was tested by intentionally scramming the reactor and then terminating the power to the primary pump. Certain transient thermal-hydraulic data were obtained preceding and during the established natural convection cooling loop composed of the upward flow through the core and the downward flow through the pool. An analysis was performed to permit the data to be extrapolated to obtain distributed fuel element flow rates and bulk temperature rises during the established cooling loop. The earliest time for the quasi-steady natural cooling loop to develop is about 2.5 min following scram. The cladding hot-spot temperature does not exceed the local saturation temperature after quasi-steady flow is established. Data are presented to assist in the modeling of the GETR natural convection loop. Semi-empirical relationships for friction factor ...

170

The effect of thermal pretreatment on the structure and creep behaviour of the alloy 800 H. Zum Einfluss der thermischen Vorbehandlung auf Struktur und Kriechverhalten des Werkstoffs Alloy 800 H  

Energy Technology Data Exchange (ETDEWEB)

Different cooling speeds after previous solution annealing at 1130deg C for 0.5 hour were simulated in laboratory experiments. The following conditions were examined: (1) Direct water quenching, (2) cooling in air for 0.5 min to 950deg C/water quenching, (3) cooling in air for 1.5 min to 750deg C/water quenching, (4) cooling in furnace for 5 min to 750deg C/water quenching. The results of the investigations have shown that a variation of the cooling conditions causes considerable changes in the creep behaviour. (orig.).

1987-01-01

171

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

172

Is cold better ? - exploring the feasibility of liquid-helium-cooled optics.  

Energy Technology Data Exchange (ETDEWEB)

Both simulations and recent experiments conducted at the Advanced Photon Source showed that the performance of liquid-nitrogen-cooled single-silicon crystal monochromators can degrade in a very rapid nonlinear fashion as the power and for power density is increased. As a further step towards improving the performance of silicon optics, we propose cooling with liquid helium, which dramatically improves the thermal properties of silicon beyond that of liquid nitrogen and brings the performance of single silicon-crystal-based synchrotrons radiation optics up to the ultimate limit. The benefits of liquid helium cooling as well as some of the associated technical challenges will be discussed, and results of thermal and structural finite elements simulations comparing the performance of silicon monochromators cooled with liquid nitrogen and helium will be given.

1999-09-30

173

High thermal load receiving heat plate  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.).

1993-09-28

174

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an ...

175

Construction progress of the cooling & ventilation in the LHC project  

CERN Document Server

After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.

2002-01-01

176

Construction Progress of the Cooling and Ventilation in the LHC Project  

CERN Document Server

The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. ...

2001-01-01

177

A comparative design study of PB-BI cooled reactor cores with forced and natural convection cooling  

International Nuclear Information System (INIS)

A comparative core design study is performed on Pb-Bi cooled reactors with forced and natural convection (FC and NC) cooling. Major interests of the study are core performance and core safety features. The designed core concepts with nitride fuel achieve reasonable breeding capability. The results of unprotected event analyses such as UTOP and ULOF show that both of concepts have possible features to withstand unprotected events due to negative reactivity feedback by Doppler effect, control rod drive line expansion, etc. These results lead to a conclusion that both of concepts have possible capability as one of future promising core concepts. A FC cooling core concept has more advantage if fuel recycle viewpoint is emphasized. (author)

2003-04-20

178

Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider  

Energy Technology Data Exchange (ETDEWEB)

Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread ...

2005-09-18

179

Nomographs for H[sub 2]O-LiBr absorption-panel cooling systems  

Energy Technology Data Exchange (ETDEWEB)

Panel cooling of buildings offers energy savings over conventional space-cooling systems. We present a procedure for calculating the performance of H[sub 2]O-LiBr absorption-panel cooling systems, in which the evaporator is the panel itself. Nomographs have been developed for this approach. Under the conditions examined, the H[sub 2]O-LiBr absorption unit operates with a theoretical performance coefficient of about 90% and with a practically constant specific cooling capacity of 2394 kJ/kg H[sub 2]O. For common values of the parameters involved, the panel cooling power varies from 25 to 175 W/m[sup 2] and the cooling water mass-flow through the panel is 40-260 g/m[sup 2]h. The thermal power needed to drive the system varies from 27 to 200 W/m[sup 2] and the associated temperatures from 70 to 100[sup o]C; thus, the system may be operated on solar energy. ...

1992-11-01

180

Calculation of current-carrying capacity of forced cooled high-voltage cable lines  

Energy Technology Data Exchange (ETDEWEB)

The current-carrying capacity of oil-filled cables is increased by forced cooling, which is accomplished by three methods: direct, surface and internal, depending on the relative positions of the cable and the cooling agent. The surface and indirect methods are the simplest and are sufficiently effective methods of cooling and make it possible to improve the current-carrying capacity of cables already mastered by the USSR's industry. A calculation method is suggested for the proper determination of the permissible load on lines of these sorts. A procedure is presented whereby equations are derived which make it possible to calculate the temperature of elements of the system and by means of an iteration calculation a determination is made of the total heat flow from the cable with which the temperature of the conductor along the line does not exceed the permissible value. The permissible current is calculated once ...

1982-01-01

181

Ultra-high pressure water jet: Baseline report  

International Nuclear Information System (INIS)

The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is recommended because of ...

1997-07-01

182

The Herschel revolution: unveiling the morphology of the high mass star formation sites N44 and N63 in the LMC  

CERN Document Server

We study the structure of the medium surrounding sites of high-mass star formation to determine the interrelation between the HII regions and the environment from which they were formed. The density distribution of the surroundings is key in determining how the radiation of the newly formed stars interacts with the surrounds in a way that allows it to be used as a star formation tracer. We present new Herschel/SPIRE 250, 350 and 500 mum data of LHA 120-N44 and LHA 120-N63 in the LMC. We construct average spectral energy distributions (SEDs) for annuli centered on the IR bright part of the star formation sites. The annuli cover ~10-~100 pc. We use a phenomenological dust model to fit these SEDs to derive the dust column densities, characterise the incident radiation field and the abundance of polycyclic aromatic hydrocarbon molecules. We see a factor 5 decrease in the radiation field energy density as a function of radial distance around N63. ...

2010-01-01

183

Standardizing regulations on production of mining electrical equipment  

Energy Technology Data Exchange (ETDEWEB)

The paper evaluates standardization of regulations on safety of electrical equipment for underground coal mines in the USSR. Factors increasing hazards of electrical failures of equipment in underground coal mines are analyzed: reduced lighting, increased humidity and dusts, damage caused by falling rocks or damage during haulage in underground workings, installation of electrical equipment in places easily accessible to untrained personnel. Standards on safety of electrical equipment for underground coal mining valid in the USSR are reviewed: the PIRNEh regulations on production of electrical equipment for coal mines developed by the VNIIVEh Institute, and the GOST national standards. International cooperation within the COMECON on safety of mining electrical equipment (the Interelectro Committee of the COMECON) is described. Certification of electrical equipment for coal mines is discussed on the example of electrical insulation types used in underground coal ...

1983-02-01

184

Fixed time and fixed point observation of environmental radioactivities in Tokyo  

Energy Technology Data Exchange (ETDEWEB)

A measurement of environmental radioactivity in Tokyo was started from 1974. We have been executing fixed time and fixed point observation since 1983 in Tokyo continuously. Measurement item is rain water, airborne dust, activated sludge at sewage treatment plants and external dose rate. Measurement data from 1983 to 1995 is reported in this paper. Moreover, we have been carried out the measurement of radon concentration in air from 1988 to 1991 in different types of residental buildings. The measurement results of rain water, airborne dust, external dose rate were approximately a background level respectively except for the Chernobyl nuclear power plant accident. Radionuclides used as radiopharmaceuticals were detected in the activated sludge at every sewage treatment plant but its concentration was lower than concentration limit in Japan. From a result of radon concentration measurements, there were no place which exceeds a radon concentration ...

1997-03-01

185

Effect of primary air content on formation of nitrogen oxides during combustion of Ehkibastuz coal  

Energy Technology Data Exchange (ETDEWEB)

Investigations are discussed carried out in a pilot plant at the Kaz. Power Engineering Scientific Research Institute into the effect of the amount of primary air in coal-dust flame on the final concentration of nitrogen oxides in flue gases. The tests were carried out in a 7500 mm high, 1600 mm dia vertical cylindrical combustion chamber having type P-57 burner, and air dispersed fuel plus additional air supplies located at the top. Amounts of coal dust fed by a drum feeder along the air pipe varied from 100-600 kg/h. The required air was supplied by 5000 m/sup 3//h Type TK-700/5 blowers at 0.04 MPa. Ehkibastuz coal samples contained: 1.3% moisture; 48.1% ash; 38.02% carbon; 2.56% hydrogen; 0.73% sulfur; 0.60% nitrogen; heat of combustion was 14.3 MJ/kg. Results obtained indicate that variations in the amount of primary air in swirl flow burners affect formation of fuel nitrogen; there is an optimum volume at which minimum quantities of ...

1986-01-01

186

Column leaching test to evaluate the use of alkaline industrial wastes to neutralize acid mine tailings  

Energy Technology Data Exchange (ETDEWEB)

Acid mine drainage is a serious environmental problem caused by the oxidation of sulfide minerals that releases highly acidic, sulfate, and metals-rich drainage. In this study, alkaline industrial wastes were mixed with acid mine tailings in order to obtain neutral conditions. A series of column leaching tests were performed to evaluate the behavior of reactive mine tailings amended with alkaline-additions under dynamic conditions. Column tests were conducted of oxidized mine tailings combined with cement kiln dust, red mud bauxite, and mixtures of cement kiln dust with red mud bauxite. The pH results show the addition of 10% of alkaline materials permits the maintenance of near neutral conditions. In the presence of 10% alkaline material, the concentration of toxic metals such as Al, Cu, Fe, Zn are significantly reduced as well as the number of viable cells (Thiobacillus ferrooxidans) compared to control samples.

2005-08-01

187

Abrasion wear studies with abrasives from brown coal beneficiation  

Energy Technology Data Exchange (ETDEWEB)

This paper evaluates abrasive jet wear tests, carried out on the ZUK-3M abrasion apparatus according to the GOSF 23.201-78 industrial standard. As abrasive material, brown coal coke dust, brown coal dust, power plant fly ash and quartz sand (for the purpose of comparison) were employed. Seventeen types of materials were blasted with abrasive jets, including a selection of steels, glass, rubber, SYS-pur plastics, cast basalt, Kawenit and vitroceramics. The test apparatus produced abrasive jet velocities between 12 and 130 ms/SUP/-/SUP/1 at rotor revolutions of 1,000 to 10,000 min/SUP/-/SUP/1. Blasted material samples were arranged at angles between 15 and 90 degrees. Various tables and graphs present abrasivity results. These results were employed for technical modifications of dedusting equipment in briquetting and coking plants, which led to a threefold increase in service life of abrasion endangered equipment parts. (8 refs.) (In German)

1983-01-01

188

Renovation of air-conditioning at La Defense; Renovation de la climatisation a La Defense  

Energy Technology Data Exchange (ETDEWEB)

Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better air quality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)

1997-05-01

189

Quality engineering and control. Semiannual progress report, May-October 1979  

International Nuclear Information System (INIS)

The following are reported: colorimetric determination of Ti in Cr, decontamination of metals by anodic dissolution, computer code for x-ray peak identification, gel-permeation chromatography of CoRezyn 1664 polyester resin, infrared monitoring of gases and vapors, particle size analysis of dusts, nondestructive analysis of Oralloy for removable alpha contamination, dissolution (digestion) of high-fired oxides, assay of U in a Pu-U alloy, measurement of oxide thickness on Pu metal by x-ray diffraction, analysis of precipitated Pu peroxide, differentiation of Dowex SBR and 11 resins, and determination of Pu solubility in simulated lung fluid.

190

Problematic of atmospheric pollution in Lebanon: the better stake is apprehended, the best acts are taken  

International Nuclear Information System (INIS)

The article is an overview on atmospheric pollution in Lebanon. It presents an analysis of sources of pollution in the country and their impacts on local and global environment and describes their control. Air pollution is mainly due to the industrial, electrical and transportation sectors. Pollutants from fuel combustion are analyzed. It is estimated that in 2010, CO_2 emissions will reach 5987250 tons, SO_2 emissions is estimated to be 182950 tons, Nox to 105180 and dusts to 4965 tons. CFC consumption and measures of control according to Montreal protocol are described. Consumption of primary energy, consumption of petroleum products, quantity of petroleum in refineries and production of cement in Lebanon are also presented in tables

2000-02-01

191

Microwave drying of fine coal  

Energy Technology Data Exchange (ETDEWEB)

Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.

1989-03-01

192

Method for treating red mud  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the handling capability of red mud, it is mixed with fine-grain coal material such as brown coal or lignite in dust form, in a ratio by weight of between 0.5-10:1. The liquid present in the red mud is bound by the very fine coal admixed therewith so that the resulting mixture can be stored in a silo and even pneumatically conveyed, and the oily properties of the red mud are removed by the treatment. The mixture is particularly suitable for use in connection with the hydrogenating liquefaction of coal in which the red mud is used as a catalyst.

1984-08-07

193

Flue gas desulfurization. Rauchgasentschwefelung  

Energy Technology Data Exchange (ETDEWEB)

Low-dust flue gases can be washed efficiently of SO/sub 2/, and the flue gas heat can be utilized. The residual heat fraction still required by the process is characterized by a temperature of 15/sup 0/K above the temperature of the purified flue gas. Marketable crystalline ammonium sulfate is produced. The high efficiency and low heat consumption are achieved by combining all process stages in a single, fully integrated cycle process free of heat and materials losses. The process is characterized by high efficiency, low investment and operating costs, recovery of thermal energy, and production of an ammonium sulfate fertilizer.

1983-04-07

194

Confrontation between stellar pulsation and evolution; Proceedings of the Conference (ASP Series, Vol. 11), Bologna, Italy, May 28-31, 1990  

International Nuclear Information System (INIS)

Attention is given to the folowing topics: population I and II variable stars; LP variables, the sun, and mass determination; and predegenerate and degenerate variables. Particular papers are presented on alternative evolutionary approaches to the absolute magnitude of the RR Lyrae variables; the evolution of the Cepheid stars; nonradial pulsations in rapidly rotating Delta Scuti stars; dynamical models of dust shells around Mira variables; and pulsations of central stars of planetary nebulae.

1990-05-28

195

Clean Technology Application : Kupola Model Burner for Increasing the Performance of Spent Accu Recycle  

International Nuclear Information System (INIS)

Recycling of used battery for recovering lead done by either small household/small scale industries has been identified as a source of air pollution, especially by heavy metal (Pb). This condition give an adverse impact toward workers and societies. Technological aspect is one of the causal. The process apply an open system. Therefore, a lot of energy, as well as dust wasted to the air without prior treatment. For overcoming this condition, closed system by utilizing Cupola furnace will be offered as one of the alternatives clean technology application and to increase the recovering performance in order to set an effective and efficient result. (author)

2000-02-01

196

Atomic power of Germany and ecology  

International Nuclear Information System (INIS)

The NPPs safety system in Germany is discussed. It is shown that there exists no threat for the German NPPs at the peace times. They release insignificant quantities of radioactive substances into the water and atmosphere. The average equivalent dose constitutes 0.0005 mSv annually. The annual equivalent dose for the personnel is equal to 4.4 mSv. At the same time, the NPPs contribute to a certain degree to the environmental medium improvement, preventing the ingress therein of the sulfur and carbon dioxide, dust and nitrogen oxides by application of fossil fuels. Attention is also paid to reprocessing facilities and also to the nuclear fuel wastes disposal. The advantages of the nuclear power engineering in comparison with the fossil fuel power engineering are enumerated

197

Aspiration cover for the loading site of a belt conveyer  

Energy Technology Data Exchange (ETDEWEB)

An aspiration cover is proposed for the site of loading a belt conveyer including a housing arranged above the belt conveyer in whose cover there is an aspiration sleeve and a discharge chute from the upper wall and a guide having a cushioning plate on the lower end. It is distinguished by the fact that in order to improve the effectiveness of removing dust by decreasing the volume of aspirated air, the cover between the aspiration sleeve and the upper wall of the loading chute is convex in the inside of the housing and has a smooth connection to the upper wall of the discharge chute turned towards the cushioning plate.

1982-01-01

198

Safety-technical characteristics of biomass, coal and straw. Final report  

Energy Technology Data Exchange (ETDEWEB)

Safety-technical factors related to spontaneous ignition and dust explosions of biomasses were investigated. Parametres of dust explosions and effect of inertisation on the maximum pressure (pmax) and the maximum rate of pressure rise (Kstmax) were studied at elevated initial pressure (1-9 bar). The level of inertisation required to prevent dust explosions totally was determined at different initial pressures. The sensitivity of fuels to spontaneous ignition and the effect of pressure on the sensitivity to and temperature of spontaneous ignition were studied on a pressurised dynamic self-ignition equipment. The effect of inertisation on the self-ignition temperature and alternatives of preventing spontaneous ignition by effective inertisation in the pressure ranges of 1 and 25 bar were investigated. As an example of application, results obtained with the laboratory test equipment were extrapolated to bin sizes used in ...

1995-12-31

199

Production of ultra high strength steels by turbulent water cooling equipment (TWICE); Production d'aciers haute resistance par un dispositif de refroidissement a turbulence controlee  

Energy Technology Data Exchange (ETDEWEB)

A new industrial process allowing to reach very high cooling rates in the cooling section after soaking of a continuous annealing line for steel sheets is presented. This process constitutes the successful conclusion of a long term research programme, jointly carried out at CRM and Arcelor Cockerill-Sambre for three years, including laboratory experiments, pilot scale trials and several industrial campaigns. It is running on from developments performed in the framework of the HOWAQ (Hot Water Quench) process. The process successively combines a moderate cooling step (600 deg C/s for 0.8 mm thick strips), in boiling water, and a faster cooling step (above 700 deg C/s), by impinging turbulent cold water in a box. Its main features are simplicity, resulting from advanced developments, soundness, flexibility and cooling homogeneity. As treated steel products are characterized by ...

2003-08-01

200

Low-temperature brown rice storage by using renewable energy from snow  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study that was conducted in Japan to determine whether renewable energy generated from snow can be used to replace the cooling system and electricity used for cooling a rice storehouse that maintained the grain temperature below 15 degrees C. However, the low-temperature storage system required a cooling system and electricity to cool rice in summer. In this study, a snow pile using 890 t of snow was made at the beginning of March next to the rice storehouse. The shape of the snow pile was a trapezium, 17 x 23 m at the bottom and 4 x 10 m at the top and 5 m in height. The snow pile was covered with 200 to 300 mm of wood chips to act as an insulation layer. Approximately 27 per cent of the energy for cooling the rice storehouse could be replaced by using the snow pile in summer. The quality of stored rice was almost similar to that of freshly harvested rice. ...

2010-07-01

201

Influence of suspended solids on pitting corrosion of carbon steel in cooling water. Tansoko no koshoku ni oyobosu reikyaku suichu no kendaku busshitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion enlarging the rust due to its deposition near the ...

1993-08-15

202

Heat-driven liquid metal cooling device for the thermal management of a computer chip  

International Nuclear Information System (INIS)

The tremendous heat generated in a computer chip or very large scale integrated circuit raises many challenging issues to be solved. Recently, liquid metal with a low melting point was established as the most conductive coolant for efficiently cooling the computer chip. Here, by making full use of the double merits of the liquid metal, i.e. superior heat transfer performance and electromagnetically drivable ability, we demonstrate for the first time the liquid-cooling concept for the thermal management of a computer chip using waste heat to power the thermoelectric generator (TEG) and thus the flow of the liquid metal. Such a device consumes no external net energy, which warrants it a self-supporting and completely silent liquid-cooling module. Experiments on devices driven by one or two stage TEGs indicate that a dramatic temperature drop on the simulating chip has been realized without the aid of any fans. The higher the ...

2007-08-07

203

Comparisons between experimental results and numerical simulations for the Sonaco sodium natural convection experiments  

International Nuclear Information System (INIS)

The SONACO experiments are conducted on an electrically heated 37-pin rod bundle, immersed in liquid sodium and contained within a hexagonal wrapper. The rig was designed to investigate natural convection cooling for a geometry representative of fast reactor fuel assemblies. Heat can be removed from the test section in several ways, but in this paper only the axial cooling mode is examined. Above the heated bundle is a plenum, at the top of which is a cooling coil containing a separate, forced sodium flow. Heat transfer from the bundle to this cooling coil is effected by means of buoyancy driven circulatory flow in the sodium, and in the axial cooling mode almost all the heat is removed by the coil. This mode is intended to simulate the natural convection cooling of a blocked fuel assembly by way of thermosyphon coupling to the inner pool. In this paper ...

204

Strong Convergence towards homogeneous cooling states for dissipative Maxwell models  

CERN Document Server

We show the propagation of regularity, uniformly in time, for the scaled solutions of the inelastic Maxwell model for small inelasticity. This result together with the weak convergence towards the homogenous cooling state present in the literature implies the strong convergence in Sobolev norms and in the $L^1$ norm towards it depending on the regularity of the initial data. The strategy of the proof is based on a precise control of the growth of the Fisher information for the inelastic Boltzmann equation. Moreover, as an application we obtain a bound in the $L^1$ distance between the homogeneous cooling state and the corresponding Maxwellian distribution vanishing as the inelasticity goes to zero.

2008-01-01

205

Steady-state neutronic investigations to the accident of water ingress in systems with pebble-bed high-temperature gas-cooled reactor fuel  

Energy Technology Data Exchange (ETDEWEB)

For light water reactors, loss of coolant is an important point in safety analysis, whereas for gas-cooled reactors the ingress of water into the core region is an incident of safety relevance. The applicability of the computer code system GAMTEREX to pebble beds of spherical high-temperature gas-cooled reactor fuel elements with simulated water ingress is verified by experiment. The measurements were performed at a Siemens-Argonaut reactor, using its ring core as a driver zone for a pebble-bed core in the center of the reactor.

1987-09-01

206

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

207

Pressure drop and heat transfer in gas-cooled rod bundles  

International Nuclear Information System (INIS)

Extensive experimental and analytical investigations of fluid flow and heat transfer in gas-cooled rod bundles have been carried out. Different bundle geometries with partially or fully roughened rod surfaces were tested in a carbon dioxide loop. An advanced and comprehensive measuring control and instrumentation are important design features of this experiment. Comprehensive thermal hydraulic subchannel analysis computer codes have been developed in order to assist fuel element design calculation for gas-cooled reactors. The experiments, codes and their verification procedure are described and the results of comparisons between measured and calculated pressure and temperature distributions are given. (orig.).

208

Nuclear reactor with external structure cooling by natural convection  

International Nuclear Information System (INIS)

The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.

209

Neutron star evolution with internal heating  

Energy Technology Data Exchange (ETDEWEB)

The thermal evolution predicted by current models of the superfluid-crust interaction is noted to differ substantially from the thermal evolution predicted by models without internal heating as well as previous models of heating. Heating rates approaching the maximum predicted by current models enhance the photon luminosity of the star in the neutrino cooling era, and dramatically alter the thermal evolution in the photon cooling era. Standard cooling models are consistent with current pulsar temperature estimates and upper limits, except those for the Vela pulsar, which are lower than predicted. 77 refs.

1989-11-01

210

Mixed structures in continuously cooled low-carbon automotive steels  

Energy Technology Data Exchange (ETDEWEB)

Mixed microstructures have been studied in low- carbon microalloyed steels suitable for automotive applications, after continuous cooling from the hot-rolled condition. Microstructural features such as polygonal ferrite, bainitic and acicular ferrite and microphase constituent are identified using transmission electron microscopy. The influence of these mixed structures on the tensile strength, impact toughness and fracture behaviour is examined. It is found that improvements in impact toughness as compared with microalloyed medium- carbon ferrite/pearlite steels can be achieved from these predominantly acicular structures developed by controlling alloy composition and continuous cooling of these lower carbon steels. (orig.).

1993-11-01

211

Mixed structures in continuously cooled low-carbon automotive steels  

International Nuclear Information System (INIS)

Mixed microstructures have been studied in low- carbon microalloyed steels suitable for automotive applications, after continuous cooling from the hot-rolled condition. Microstructural features such as polygonal ferrite, bainitic and acicular ferrite and microphase constituent are identified using transmission electron microscopy. The influence of these mixed structures on the tensile strength, impact toughness and fracture behaviour is examined. It is found that improvements in impact toughness as compared with microalloyed medium- carbon ferrite/pearlite steels can be achieved from these predominantly acicular structures developed by controlling alloy composition and continuous cooling of these lower carbon steels. (orig.).

1993-06-01

212

Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides  

Energy Technology Data Exchange (ETDEWEB)

The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)

2004-07-01

213

HPOF transmission-system economic-evaluation program. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.

1983-01-01

214

Experimental 1 kW 20 cell PEFC stack  

Energy Technology Data Exchange (ETDEWEB)

A 20-cell PEFC stack was designed and built. Resin impregnated graphite was used as bipolar plate material. The air cooling of the stack was optimized by introducing high surface structures into the open space of the cooling plates. At {eta} (H{sub 2} LHV) = 0.5 a power of 880 W was obtained under conditions of low gas-pressures of 1.15 bar{sub a}. The auxiliary power for process air supply and cooling at 880 W power is less than 7% of the power output, indicating that the described system may be operated at a high efficiency. (author) 5 figs., 2 refs.

1999-08-01

215

Enhanced LMR core cooling utilizing passive vortex devices  

International Nuclear Information System (INIS)

This paper reports several design options for improved passive circulation flow investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.

1988-05-01

216

Enhanced LMR [liquid metal reactors] core cooling utilizing passive vortex devices  

International Nuclear Information System (INIS)

Several design options for improved passive circulation flow have been investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.

1988-05-01

217

Emergency core cooling device for a reactor  

International Nuclear Information System (INIS)

Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).

1982-01-24

218

Convection in the cavity between two rollers: The effect of thermal boundary conditions  

Energy Technology Data Exchange (ETDEWEB)

In this study the authors examine the convective cooling provided by fluid trapped in the cavity between two consecutive rollers in a roller bearing. In order to calculate the steady-state temperature of the roller, the designer must know nor only the rolling-contact heat input received by the roller but also the convection cooling effect of the surrounding fluid. Until recently, this lateral convection cooling effect was modeled by assuming a certain (constant) heat transfer coefficient h at the roller surface, and then calculating the steady-state temperature distribution around the roller.

1991-02-01

219

Chalk Point Cooling Tower Project. Environmental systems corporation's comprehensive project status report for FY75, July 1, 1974--October 1, 1975. [Environmental effects of natural draft cooling towers of oil-fired power plant  

Science.gov (United States)

Results are reported from initial characterization tests on the environmental effects of the natural draft cooling tower of the Chalk Point Unit 3 oil-fired power plant located on the shore of Chesapeake Bay. Data are included on updraft air velocity, plume drift, and sea salt deposition in relation to meteorological conditions.

1976-05-01

220

Assessment of cooling effects on extending the maximum operating time for the Syrian Miniature Neutron Source Reactor  

International Nuclear Information System (INIS)

Various schemes of cooling have been investigated for the purpose of assessing potential benefits on the operational characteristics of the Syrian MNSR reactor. A detailed thermal hydraulic model for the analysis of MNSR has been developed. The analysis shows that an auxiliary cooling system, installed in the pool which surrounds the lower section of the reactor vessel, will significantly offset the consumption of excess reactivity due to the negative reactivity temperature coefficient, Hence, the maximum operating time of the reactor is extended. Compared with experimental data, the suggested model proves to be valid for the analysis of MNSR behavior under both steady state and transient conditions. (author)

2007-01-01

221

Weather - Hanford Site  

Science.gov (United States)

to Cool Spots Hanford Fun Facts Classroom Projects Famous People of Hanford Counterintelligence Home Employee Responsibilities CI Information CI Resources Points of Contact...

2011-10-01

222

Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems  

Energy Technology Data Exchange (ETDEWEB)

In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

2006-03-01

223

Traveling Wave RF Systems for Helical Cooling Channels  

Energy Technology Data Exchange (ETDEWEB)

The great advantage of the helical ionization cooling channel (HCC) is its compact structure that enables the fast cooling of muon beam 6-dimensional phase space. This compact aspect requires a high average RF gradient, with few places that do not have cavities. Also, the muon beam is diffuse and requires an RF system with large transverse and longitudinal acceptance. A traveling wave system can address these requirements. First, the number of RF power coupling ports can be significantly reduced compared with our previous pillbox concept. Secondly, by adding a nose on the cell iris, the presence of thin metal foils traversed by the muons can possibly be avoided. We show simulations of the cooling performance of a traveling wave RF system in a HCC, including cavity geometries with inter-cell RF power couplers needed for power propagation.

2009-05-01

224

Thermo-economic analysis of solar powered adsorption heat pump  

British Library Electronic Table of Contents (United Kingdom)

The economic feasibility of the residential solar thermal (ST) cooling system designed in the companion article [1] is ascertained by comparing it with a solar electric (SE) cooling system, and also with the baseline (i.e., control case), a grid dependent, highest efficiency COPC=5.66 heat pump. The economic scenario is analyzed for 24 cities across the southern USA, south of the 37degreeN. The SE cooling system provides lifecycle (20 year) savings to the homeowner only where electric rates are high and it is heavily subsidized. The overall societal effect (sum of taxpayer funded rebate and homeowner savings) is actually an increased cost everywhere except the California Central Valley, where the net savings is $1500. In the same valley, The ST cooling system provides greater lifecycle sav...

2007-01-01

225

Thermal control of electric vehicle batteries  

Energy Technology Data Exchange (ETDEWEB)

The need to operate electric vehicles in warm, summer conditions and also provide for long periods of standby in cold climates is a challenging problem for any battery system. All advanced batteries of high specific energy require active cooling systems because adiabatic heating will raise the temperature to a level that is deleterious to cycle life. This cooling requires efficient paths for escape of heat to cooled surfaces; cooling the exterior of modules is insufficient. If a battery is heated by its own energy, and insulated to withstand exposure to a cold climate, only vacuum insulation will afford an appreciable reduction (>10{degrees}C) in the ambient temperature that can be tolerated. Standard insulations are of little use for this purpose because the heat loss rate causes too high a drain on the battery energy even for near-ambient temperature batteries.

1995-07-01

226

The Goddard Library - Goddard Projects Directory - NASA  

Science.gov (United States)

Oct 2, 2007 ... Other payloads included the Orbiter Experiments Autonomous Supporting Instrumentation System-1 (OASIS-1), a cooling system designed for ...

227

Solar-powered cooling systems: Technical and economic analysis on industrial refrigeration and air-conditioning applications  

British Library Electronic Table of Contents (United Kingdom)

In the last years, the growing demand for air conditioning has caused a significant increase in demand for primary energy resources. Solar-powered cooling is one of the technologies which allows to obtain, by using the renewable solar source, an important energy saving compared to traditional air conditioning plants. The paper describes different technical installations for solar cooling, their way of operation, advantages and limits. The objective of the present study has been to analyze the technical and economic feasibility of solar absorption cooling systems, designed for two different application fields: industrial refrigeration and air conditioning. The possibility to replace or integrate the existing plants is studied, by considering the refrigeration requirements of a company, whic...

2009-01-01

229

RESEARCH MEMORANDUM - NASA Technical Report Server (NTRS)  

Science.gov (United States)

lytical Comparison of Turbine-Blade Cooling System Designed for a. TurboJet Engine Operat- at Supersonic Speed and Altitude. I1 -. Air-C~Oling Systems. ...

231

Numerical simulations of nucleate boiling in impinging jets: Applications in power electronics cooling  

Energy Technology Data Exchange (ETDEWEB)

Boiling jet impingement cooling is currently being explored to cool power electronics components. In hybrid vehicles, inverters are used for DC-AC conversion. These inverters involve a number of insulated-gate bipolar transistors (IGBTs), which are used as on/off switches. The heat dissipated in these transistors can result in heat fluxes of up to 200 W/cm{sup 2}, which makes the thermal management problem quite important. In this paper, turbulent jet impingement involving nucleate boiling is explored numerically. The framework for these computations is the CFD code FLUENT. For nucleate boiling, the Eulerian multiphase model is used. The numerical results for boiling water and R113 jets (submerged) are validated against existing experimental data in the literature. Some representative IGBT package simulations that use R134a as the cooling fluid are also presented. (author)

2008-01-15

232

Liquid level control system of fast reactor secondary cooling system  

International Nuclear Information System (INIS)

Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).

233

Introduction & Overview to Symposium 240: Binary Stars as ...  

Science.gov (United States)

... CVn) consisting of a dM3 star and a cool white dwarf that must have evolved through the common-envelope stage of binary star evolution (Else van ...

2011-05-14

234

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

235

Hanford Speakers Bureau - Hanford Site  

Science.gov (United States)

to Cool Spots Hanford Fun Facts Classroom Projects Famous People of Hanford Counterintelligence Home Employee Responsibilities CI Information CI Resources Points of Contact...

2011-10-02

236

FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...  

Science.gov (United States)

was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...

237

Cryogenic trick for enhanced cooling using liquid nitrogen  

International Nuclear Information System (INIS)

The thermal transpiration method has been employed to replace the temperature of liquid nitrogen by #approx#12 K. This is done by bubbling He (g) through the liquid nitrogen.

1993-01-01

238

Collisional Cooling of Negative Ion Beams  

Science.gov (United States)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

239

Collisional Cooling of Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

240

Alpha/Beta Heat Treatment of a Titanium Alloy with a Non ...  

Science.gov (United States)

... transformed at 705°C. The cooling rate and temperature dependence of matrix decomposition for Ti6242 was thus similar to that for Ti64 x [9]. ...

2006-08-01

241

System behavior after a loss of electric power in HANARO  

International Nuclear Information System (INIS)

A LOss of Electric Power(LOEP) experiment was conducted after a 30MW full power operation as one of the reactor performance tests to verify the design characteristics of the HANARO. The objective of LOEP test was to investigate the integral behaviors of the system and the components as well as the cooling characteristics when the electric power was lost unexpectedly. Through the test, it was confirmed that the residual heat from the core was safely removed by the natural convection cooling and the assistant power systems operated normally

2005-04-11

242

Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976  

International Nuclear Information System (INIS)

A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).

1994-10-18

243

SUSTAINABLE H/C SYSTEMS FOR CHICKEN FARMS IN SYRIA  

Energy Technology Data Exchange (ETDEWEB)

Space heating/cooling systems account for approximately 30% of the global energy consumption. Such systems contribute to global warming by emitting 0.39.1011 MWh of heat and 2.9.1010 tons of CO{sub 2}. There is a general understanding that the way to reduce global warming is a more efficient use of energy and increased use of renewable energy in all fields of the society. The poultry industry in the Mid East is an important business. There are e.g. 13000 chicken farms in Syria producing 172,000 ton of meat. This industry employs directly almost 150,000 people. The total investment in chicken farming is 130 BSP. Even though, the annual mean temperature in Syria is {approx}15-18 C the winter temperatures are close to freezing for two months. Since the chickens need a temperature of 21-35 C, depending on age, approximately 168.103 tons of coal (1170 GWh) is consumed for heating these plants. The chicken farms have no cooling systems since ...

2008-09-30

244

Rural residential application of geothermal heat pump. Final grant report  

Energy Technology Data Exchange (ETDEWEB)

A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)

1982-07-30

245

Regional spinal cord blood flow during local cooling  

Energy Technology Data Exchange (ETDEWEB)

We used the tissue distribution of ({sup 14}C)butanol to quantitate regional blood flow in the spinal cord (RSCBF) of pentobarbital-anesthetized, normothermic rats in which segmental local cooling pentobarbital-anesthetized, normothermic rats in which segmental local cooling of the spinal cord (to 25-28{degrees}C) at vertebral levels C4-C6 (n = 6) or T13-L1 (n = 6) was induced. Thirty minutes later, blood flow measurements were made at seven levels of the spinal cord and in the sciatic nerve trunks and biceps femoris muscles. Sham-cooled rats served as controls (n = 12). In control rats, RSCBF varied between 41.5 +/- 2.4 and 65.1 +/- 3.2 ml.min-1.100 g-1. Local cooling of the C4-C6 cord segment reduced RSCBF by 32%, from 65.1 +/- 3.2 to 44.4 +/- 3.5 ml.min-1.100 g-1 (P less than 0.01). Tissue vascular resistance (R) in the cooled C4-C6 segment was elevated versus control. There were ...

1990-06-01

246

Numerical simulation of the unsteady and turbulent flow in a high-pressure turbine stage; Simulation numerique de l'ecoulement instationnaire et turbulent dans un etage de turbine haute pression  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study concerns the use of numerical methods for the resolution of the Reynolds Averaged Navier Stokes equations adapted to the simulation of the cooling of the trailing edge of a stator in a high pressure turbine. These methods, based on the elsA solver developed at ONERA, use a four steps Runge Kutta time discretization scheme and a Jameson centered space discretization scheme. The scheme is applied through a finite volume approach on control volume centered on the cells of a multi-block structured mesh. Turbulence is simulated either through the algebraic Michel model, or through the one-transport-equation Spalart-Allmaras model, or through the two-transport-equations k 1, k {omega} and k {epsilon} models, and through ASM model. A simulation of the flow in a bidimensional stator, without cooling, is carried out. The cooling, which is realized with trailing edge slots, is then simulated on a bidimensional ...

2004-09-15

247

MR-6 type fuel elements cooling in natural convection conditions after the reactor shut down  

International Nuclear Information System (INIS)

Natural cooling conditions of the nuclear fuel in the channel type reactor after its shut down are commonly determined with relatively high uncertainty. This is not only to he lack of adequate measurements of thermal parameters i.e. the residual power generation, the coolant flow and temperatures, but also due to indeterminate model of convection mechanism. The numerical simulation of natural convection in multitube fuel assembly in the fuel channel leads to various convection modes including evidently chaotic behaviour. To determine the real cooling conditions in the MARIA research reactor a series of experiments has been performed with fuel assembly equipped with a set of thermocouples. After some forced cooling period (the shortest was half an hour after the reactor shut down) the reactor was left with the only natural convection. Two completely different cooling modes have been observed. The MARIA ...

2002-03-17

248

Local analysis of three-dimensional air cooled condenser using a two-phase flow diagram  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with the development and application of an analytical method for the performance prediction of air cooled condensers. A local analysis is employed in which the condenser is considered as a matrix of small basic heat transfer modules. For each element, local film coefficients for both the air and the condensing fluid are determined according to the existing local conditions, including the two-phase flow regime. The paper considers an application of the method to heat pump condensing.

1983-07-01

249

Liquid metal cooled fast breeder reactor comprising electromagnetic braking systems of the coolant flow  

International Nuclear Information System (INIS)

The liquid-metal-cooled fast breeder reactor presented includes a fuel assembly made up of several long sub-assemblies rising side by side. Each of the sub-assemblies of an external area of the fuel assembly comprises an electromagnetic braking system for regulating the flow of coolant in the sub-assembly, the magnetic fields of the braking systems being temperature sensitive.

250

Investigation on natural convection decay heat removal for the EFR: Status of the program  

International Nuclear Information System (INIS)

The European Research and Development Program on decay heat removal by natural convection for the European Fast Reactor (EFR) covers the calculational methods and the model experiments performed for code validation. The studies concentrate on important physical effects of the cooling modes within the primary system and the direct reactor cooling circuits and include fundamental tests as well as reactor experiments. (author)

1991-11-05

251

Heat pipe cooled piston - feasibility study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating heat pipe, in which the return of the condensate to the ...

2004-07-01

252

Dry storage concepts and their thermodynamic layout  

International Nuclear Information System (INIS)

The two favourable dry storage concepts being under consideration in the Federal Republic of Germany are presented and the physical behaviour or natural convection cooling with air is explained. With the three examples cask store, vault storage horizontally and vertically arranged the main thermodynamical design parameters and their influence on the efficiency of the cooling system and on the temperature distribution inside the store and of the stored material are discussed. Moreover, the importance of the fulfilment and the harmony of all safety criteria and the difficulties while to do so are carried out especially with the vault store.

253

Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report  

Energy Technology Data Exchange (ETDEWEB)

This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as ...

1984-07-01

254

Combined-cycle cogen plant a successful good neighbor  

Energy Technology Data Exchange (ETDEWEB)

This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.

1993-04-01

255

Chalk Point Cooling Tower Project: Cooling Tower Effects on Crops and Soils. Preoperational Report, Appendix.  

Science.gov (United States)

This report contains data collected on a monthly basis over the period April, 1973 - April, 1975 for dustfall particulates, sodium and chloride and SO2 levels obtained from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO and ...

1976-01-01

256

Chalk Point Cooling Tower Project: Cooling Tower Effects on Crops and Soils. Post Operational Report No. 2.  

Science.gov (United States)

This report contains a summary of monthly dustfall, SO2, rainfall, crops and soils information obtained over the period May, 1976 to March, 1977 from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO which is located 65 km sout...

1977-01-01

257

Thermal analysis of spent fuel in shuttle station during dry transfer under abnormal cooling conditions for TAPS - 4  

International Nuclear Information System (INIS)

A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle ...

2006-11-13

258

System Analysis for Decay Heat Removal in Lead-Bismuth Cooled Natural Circulated Reactors  

Science.gov (United States)

Decay heat removal analyses for lead-bismuth cooled natural circulation reactors are described in this paper. A combined multi-dimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural circulation reactors. For the preliminary study, transient analysis has been performed for a 100 MWe lead-bismuth-cooled reactor designed by Argonne National Laboratory (ANL). In addition, decay heat removal characteristics of a 400 MWe lead-bismuth-cooled natural circulation reactor designed by Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. PRACS (Primary Reactor Auxiliary Cooling System) is prepared for the JNC's concept to get sufficient heat removal capacity. During 2000 sec after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 Centigrade, because the buoyancy force in ...

2002-07-01

259

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

Energy Technology Data Exchange (ETDEWEB)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular ...

1995-03-01

260

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

International Nuclear Information System (INIS)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular ...

261

Status of he-cooled divertor development (PPCS subtask TW4-TRP-001-D2)  

International Nuclear Information System (INIS)

Within the framework of the EU power plant conceptual study (PPCS), helium-cooled modular divertor concepts have been investigated in detail at the Forschungszentrum Karlsruhe during the past few years. The first conceptual design proposed was based on convective cooling with the use of flow promoters in the form of pin and/or slot arrays (HEMP/HEMS) to increase the cooling surface and, hence, enhance the heat transfer capacity. While continuing the design optimisation, an advanced multiple-jet design (HEMJ) was introduced, which is based on direct jet-to-wall impinging cooling and offers advantages in terms of simple construction and manufacturing. Main emphasis of the 2004 work program (TW4-TRP-001) lay on experiments for the concepts HEMJ and HEMS, which were mainly performed at the Efremov Institute in St. Petersburg, Russia. For experiment preparation, detailed test programs were worked out and ...

262

Performance characteristics of a natural circulation cooling/latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As a result of a 48 hour simulation experiment with load ...

1987-09-25

263

Performance analysis on a hybrid air-conditioning system of a green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system at a latent load of 30% and this improving can be achieved by ...

2006-05-15

264

Parametric study of radiative cooling of solid antihydrogen. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is localized and hydrogen's ...

1989-03-01

265

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses therefrom; a gravity driven cooling water pond-containing space, the gravity ...

1991-10-22

266

Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is ...

1994-07-01

267

Emergency reactor core cooling device  

International Nuclear Information System (INIS)

The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the structure. Accordingly, a ...

1993-03-16

268

Emergency core cooling device  

International Nuclear Information System (INIS)

In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, ...

1990-10-29

269

Chalk point cooling tower project: effects of simulated saline cooling tower drift on woody species. Master's thesis  

Science.gov (United States)

Cooling towers of power plants are used to dissipate waste heat into the atmosphere. If saline water is used for cooling, a saline aerosol known as drift is released into the atmosphere. Drift effects on vegetation are not well known. To simulate drift for a field study, cooling tower basin water was sprayed thirty separate times during a 46-day period in 1975 on Virginia pine (Pinus virginiana), flowering dogwood (Cornus florida), tulip tree (Liriodendron tulipfera), and California privet (Ligustrum ovalifolium), Norway spruce (Picea abies), and white ash (Fraxinus americana) were added in 1976 and all trees were sprayed 43 times during a 59-day period. Only dogwood leaves showed significant injury. Absence of injury on other species was probably due to the ability of their leaves to exclude, or reduce absorption of, toxic concentrations of the ions supplied.

1977-07-01

270

Ab initio Stellar Astrophysics: Reliable Modeling of Cool White Dwarf Atmospheres  

CERN Document Server

Over the last decade {\\it ab initio} modeling of material properties has become widespread in diverse fields of research. It has proved to be a powerful tool for predicting various properties of matter under extreme conditions. We apply modern computational chemistry and materials science methods, including density functional theory (DFT), to solve lingering problems in the modeling of the dense atmospheres of cool white dwarfs ($T_{\\rm eff}\\rm <7000 \\, K$). Our work on the revision and improvements of the absorption mechanisms in the hydrogen and helium dominated atmospheres resulted in a new set of atmosphere models. By inclusion of the Ly-$\\rm \\alpha$ red wing opacity we successfully fitted the entire spectral energy distributions of known cool DA stars. In the subsequent work we fitted the majority of the coolest stars with hydrogen-rich models. This finding challenges our understanding of the spectral evolution of ...

2010-01-01

271

Aerosol Properties Over the United Arab Emirates and Arabian Gulf from MISR Multi-angle Satellite Imaging  

Science.gov (United States)

The MISR instrument aboard NASA's Terra satellite participated in the UAE-2 campaign, August-October 2004. This campaign represented a unique opportunity to study the complex aerosol situation in the Arabian Gulf region, in the context of a first-rate collection of aircraft and surface-based instruments, giving us the opportunity to do some groundbreaking satellite aerosol validation work. We aimed (1) to validate MISR aerosol retrieval results for dust and pollution particles over dark and light surfaces, and (2) to contribute regional maps of aerosol optical thickness (AOT) and particle micro-physical properties, giving spatial context to the field-instrument measurements, and moving toward a satellite-based regional aerosol climatology. The validation effort benefited from the combination of an instrumented aircraft and a regional network of surface-based sun photometers. We obtained high-quality sub-orbital data coincident with MISR overpasses on three days: ...

2005-12-01

272

Spitzer Mid-infrared Study of Compact HII Regions in the Magellanic Clouds  

CERN Document Server

We present a study of the mid-infrared properties and dust content of a sample of 27 HII ``blobs'', a rare class of compact HII regions in the Magellanic Clouds. A unique feature of this sample is that even though these HII regions are of high and low excitation they have nearly the same physical sizes ~1.5-3 pc. We base our analysis on archival 3-8 microns infrared imagery obtained with the Infrared Array Camera (IRAC) on board the Spitzer Space Telescope. We find that despite their youth, sub-solar metallicity and varied degrees of excitation, the mid-infrared colors of these regions are similar to those of typical HII regions. Higher excitation ``blobs'' (HEBs) display stronger 8 micron emission and redder colors than their low-excitation counterparts (LEBs).

2008-01-01

273

Spitzer Imaging of Herschel-ATLAS Gravitationally Lensed Submillimeter Sources  

CERN Document Server

We present physical properties of two submillimeter selected gravitationally lensed sources, identified in the Herschel Astrophysical Terahertz Large Area Survey. These submillimeter galaxies (SMGs) have flux densities > 100 mJy at 500 um, but are not visible in existing optical imaging. We fit light profiles to each component of the lensing systems in Spitzer IRAC 3.6 and 4.5 um data and successfully disentangle the foreground lens from the background source in each case, providing important constraints on the spectral energy distributions (SEDs) of the background SMG at rest-frame optical-near-infrared wavelengths. The SED fits show that these two SMGs have high dust obscuration with Av ~4 to 5 and star formation rates of ~100 M_sun/yr. They have low gas fractions and low dynamical masses compared to 850 um selected galaxies.

2010-01-01

274

Problematic of atmospheric pollution in Lebanon: the better stake is apprehended, the best acts are taken  

International Nuclear Information System (INIS)

Lebanon has imported in 1996 5000 Kt of carburants causing about 80 Kt of SO_x; 40 Kt of NO_x; 3 Kt of dusts and 3.5 million tons of CO_2. The atmospheric pollution in Lebanon is due to three main sources: - Thermal central of electric production - Industries (cement) - Transportation sector The document describes in tables: the inventory of pollutants and pollutant emissions in 1993 and 2010; industrial and heating gas oil; liquified petroleum gas commercial propane; fuel oil for EDL; consumption of energy in 1996; sectorial distribution of pollutants PPM; emissions of CO_2 per tons per habitant in 1993; consumption in 1993 broken down by use and application. Finally, three projects concerning public transportation were presented

1999-06-02

275

Potentially pathogenic free-living amoebae isolated from hospital wards with immunodeficient patients in Tehran, Iran  

British Library Electronic Table of Contents (United Kingdom)

This study investigated the occurrence of free-living amoebae (FLA) in immunodeficiency wards of hospitals in Tehran, Iran. A total of 70 dust and biofilm samples from wards serving transplant, pediatric (malignancies), HIV, leukemia and oncology patients of five university hospitals were collected and examined for the presence of FLA using culturing and molecular approaches. Based on the morphology of the amoebae in plate cultures, primer sets were applied for molecular identification of Acanthamoeba, vahlkampfiid amoebae and Hartmannella. Out of 70 samples, 37 (52.9%) were positive for FLA. Acanthamoeba belonged to the T4 genotype was the most prevalent isolate. Presence of the T4 genotype on medical instruments, including an oxygen mask in an isolation room of an immunodeficiency pediat...

2011-01-01

276

Pilot project ''measurement of efficacy'' - biological monitoring of antimony pollution in the Munich test area using a standardized grass culture  

International Nuclear Information System (INIS)

This pilot project was carried out for the purpose of testing methods for active biological monitoring. It covered a period of three years (until September 1994), including two years of exposure. The measurements served to determine pollutant levels in plants used as animal fodder and dust-borne heavy metal concentrations in different sites and, on this basis, to obtain indirect information on human exposure. Among others, the pilot project investigated the suitability of Italian rye-grass as a biological indicator for aluminium, arsenic, cadmium, cobalt, chromium, copper, iron, mercury, magnesium, manganese, nickel, lead, platinum, antimony, titanium, and zinc. (orig./GL).

277

Photoluminescence Decay of Irradiated Herbs  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt){sup -P}. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)

1999-07-01

278

Photoluminescence Decay of Irradiated Herbs  

International Nuclear Information System (INIS)

Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt)"-"P. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)

1998-07-05

279

Natural gas and quality of fuels for the reduction of atmospheric pollution  

International Nuclear Information System (INIS)

The production of atmospheric pollutants in combustion processes depends on plant characteristic, combustion conditions and fuel quality. The influence of fuel quality on the emission of sulphur oxides, nitrogen oxides, carbon monoxide, dust and carbon dioxide and on the emission of some toxic pollutants, such as heavy metals and polycyclic aromatic hydrocarbons, is analysed. The comparison between the emission limits, fixed by the Italian legislation, and the uncontrolled pollutant emissions, produced by fossil fuel combustion in power plants and industrial use, shows that, in order to comply with the limits, a reduction of pollutant emissions is required through the use of abatement systems and cleaner fuels where natural gas has a primary role. The use of cleaner fuels is particularly required in heating plants and appliances for the residential sector, where the development of new gas technologies further increases the environmental advantages of natural gas in ...

1998-01-01

280

Lead content of fetal tissues after maternal intoxication  

Energy Technology Data Exchange (ETDEWEB)

A female employee was exposed to lead dust for 8 h daily from 4.5.1982 to 20.5.1982. During this time conception occurred (1st day of last menses 4.5.82). Acute symptoms of lead intoxication were not observed in this subject but were in other employees. Measurements of lead content were started after the end of exposure and continued for 6 months until normal values were obtained. Because of the half-life of nearly 20 days for lead elimination from blood the estimated body burden at the end of exposure was about 1200 ppb. The fetal tissue samples contained between 0.4 (brain) and 7.9 (liver) ..mu..g lead/g dry weight. The fetal lead was mainly stored in bone, blood and liver. From the results given a delayed elimination of fetal lead is suggested.

1986-02-01

281

Junction conditions in General Relativity with spin sources  

CERN Document Server

The junction conditions for General Relativity in the presence of domain walls with intrinsic spin are derived in three and higher dimensions. A stress tensor and a spin current can be defined just by requiring the existence of a well defined volume element instead of an induced metric, so as to allow for generic torsion sources. In general, when the torsion is localized on the domain wall, it is necessary to relax the continuity of the tangential components of the vielbein. In fact it is found that the spin current is proportional to the jump in the vielbein and the stress-energy tensor is proportional to the jump in the spin connection. The consistency of the junction conditions implies a constraint between the direction of flow of energy and the orientation of the spin. As an application, we derive the circularly symmetric solutions for both the rotating string with tension and the spinning dust string in three dimensions. The rotating string with tension ...

2006-01-01

282

Interferometer Observations of Subparsec-scale Infrared Emission in the Nucleus of NGC 4151  

CERN Document Server

We report novel, high-angular resolution interferometric measurements that imply the near-infrared nuclear emission in NGC 4151 is unexpectedly compact. We have observed the nucleus of NGC 4151 at 2.2 microns using the two 10-meter Keck telescopes as an interferometer and find a marginally resolved source ~0.1 pc in diameter. Our measurements rule out models in which a majority of the K band nuclear emission is produced on scales larger than this size. The interpretation of our measurement most consistent with other observations is that the emission mainly originates directly in the central accretion disk. This implies that AGN unification models invoking hot, optically thick dust may not be applicable to NGC 4151.

2003-01-01

283

Grain mantles: The impact on grain evolution and selective extinction  

International Nuclear Information System (INIS)

Depletion studies are used to infer the presence of mantles and to constrain grain evolutionary models in the diffuse interstellar medium. The presence of these mantles appears to be important in the evolution of the grains inside diffuse as well as dense clouds. In dense clouds where the element-to-element abundances sometimes differ from those found in diffuse clouds, empirical relationships are starting to emerge between gas abundances and various types of peculiar selective extinction. These peculiar extinction curves may be the results of nonvolatile mantle formation on grain cores or may reflect chemical differences due to variations in the intrinsic metalicity from one cloud to another. A simple model of the time evolution of a parcel of gas and dust as observed by the depletion of two elements is presented. Different studies of grain evolution and selective extinction are discussed and compared.

1989-12-01

284

Flame propagation characteristics and flame structures of zirconium particle cloud in a small-scale chamber  

British Library Electronic Table of Contents (United Kingdom)

Flame propagating through zirconium particle cloud in a small-scale vertical rectangle chamber was investigated experimentally. In the experiments, the zirconium quoted 99% purity was used and the diameter of particles was distributed 1?22 ?m. The zirconium dust was dispersed into the chamber by air flow and ignited by an electrode spark. A high-speed video camera was used to record the images of the propagating flame. Micro-thermocouples, schlieren optical system and microscopic lens were used to obtain temperature profiles and flame structure, respectively. Based on the experimental results, flame propagation characteristics and flame structure of zirconium particle cloud were analyzed. The propagation velocity of the flame is quite slow in the initial 14 ms and then accelerates to maxim...

2010-01-01

285

Engine use of producer gas, experiences and requirements  

Energy Technology Data Exchange (ETDEWEB)

The most effective way to generate electricity out of biomass is the gasification and the use of the gas in a gas engine. The conversion of the organic carbon with the gasification of biomass is higher than 95 %. Depending on the gasification concept, the efficiency of gasifiers is found between 70 and 90 %. If the pyrolysis gas is used in a gas engine, an electric efficiency of about 26 % referring to the primary amount of energy can be obtained. With efficient gas cleaning (cleaning for tar and dust), pyrolysis gas is well qualified for engine combustion. Through modern state of engine controlling there are ways to have complete control of the fluctuations in the gas composition. Furthermore, the minor calorific value of offered wood gas poses no problem for turbo charged lean-burn gas engines. (orig.)

1999-07-01

286

Dismantling by explosives  

Energy Technology Data Exchange (ETDEWEB)

Explosives have rarely been used in decommissioning of nuclear reactors. Nevertheless, controlled blasting can be used advantageously during careful destruction of nuclear power plants for removal of concrete, pipe systems, and other components. Experiments performed within a former nuclear power plant demonstrate the feasibility of this method, employing explosive masses up to 15 kg per blast. The loadings of the components and the total plant structure were measured and compared with code predictions. The experiments show a response of the containment predominantly in frequency ranges above 100 Hz, thus keeping the building and components below German regulation limits for shock excitation. The blast wave pressures are reduced drastically within short distances in the building. Dust and debris can be contained with simple methods such as curtains. Use of this method seems to be applicable to actual dismantling projects.

1989-08-01

287

Decontamination factor of an incinerator for radioactive solid wastes  

International Nuclear Information System (INIS)

An incinerator for the treatment of low-level radioactive solid wastes was installed in Tokai Research Establishment, JAERI, 1966. The incinerator was equipped with a scrubber, cyclone, electrostatic precipitator and HEPA filter. The retention factor (R.F.) of the furnace as well as the decontamination factors (D.F.) of each dust collector were measured using "3"2P as a tracer under various conditions. It was found that the overall D.F. of the incinerator was improved by the increase of the temperature in the furnace, decrease of the off gas flowrate, increase of the charged voltage of the electrostatic precipitator and by the increase of the liquid gas ratio of the scrubber. The overall D.F. of the incinerator (including the R.F. in the furnace) on the standard operating conditions was 9.1x10"6. (auth.).

288

Closed-form solutions for some metric perturbations from a closed Friedmann model and the distortion of the universe  

International Nuclear Information System (INIS)

We consider perturbations of a particular type (homogeneous of Bianchi type IX) from a closed Friedmann-Robertson-Walker model. By considering a perfect fluid, we obtain closed-form solutions for the perturbations in three interesting cases: stiff matter, radiation, and dust. As a cosmological application, we obtain an upper limit on the relative shear, (sigma/theta)_0 < b/sub 0exp/, if the microwave background radiation was last scattered at a mean red-shift element of [7,10"3] and the density parameter is #OMEGA# element of (1,10), where b/sub 0exp/ is the relative root-mean-square deviation of the temperature over the whole sky.

289

Brane-world cosmology with black strings  

CERN Document Server

We consider the simplest scenario when black strings (cigars) penetrate the cosmological brane. As a result, the brane has a Swiss-cheese structure, with Schwarzschild black holes immersed in a Friedmann-Lema\\^{\\i}tre-Robertson-Walker brane. There is no dark radiation in the model, the cosmological regions of the brane are characterized by a cosmological constant $\\Lambda$ and flat spatial sections. Regardless of the value of $\\Lambda$, these brane-world universes forever expand and forever decelerate. The totality of source terms in the modified Einstein equation sum up to a dust, establishing a formal equivalence with the general relativistic Einstein-Straus model. However in this brane-world scenario with black strings the evolution of the cosmological fluid strongly depends on $\\Lambda$. For $\\Lambda$ less or equal to zero it has positive energy density $\\rho$ and negative pressure $p$ and at late times it behaves as in the Einstein-Straus model. For ...

2006-01-01

290

Application research on three-dimensional virtual mine in the framework of internet of things  

British Library Electronic Table of Contents (United Kingdom)

Based on the information system characteristics of mine, proposed network architecture design of the mine property. And in this framework based on the design of three-dimensional virtual mine described the application of intelligent management platform. Three-dimensional virtual underground mine that shows the situation, the core application is through remote monitoring system of information exchange between devices (material object communication). Internet of things in the framework of mining three-dimensional virtual reconstruction of mine. On coal mine safety in the production process of human, machine and environment, control elements and their harmony and unity. 3D virtual mine management platform integrates personnel positioning, dust control, gas monitoring, roof pressure monitoring...

2011-01-01

291

Air pollution in Berlin and its surroundings in 1989. Luftverschmutzung in Berlin und Umgebung im Jahr 1989  

Energy Technology Data Exchange (ETDEWEB)

The report presents details of the distributions of air pollution in the Berlin area and the developments of the past 20 years. Highly polluted areas are indicated in which air pollution reduction measures are particularly urgent. The report therefore intends not only to inform but also to point out the deficiencies of air pollution abatement measures, so that political consequences can be derived and measures can be taken. In all, data were recorded by 39 measuring stations in West Berlin, 16 in East Berlin, and 7 in Potsdam and Frankfurt/Oder. In most stations, sulphur dioxide and airborne dust were measured; 14 stations in West Berlin and one in East Berlin measured carbon monoxide and nitric oxides; 8 stations in West Berlin recorded ozone concentrations. (orig./KW).

1990-10-01

292

ARIES-AT safety design and analysis  

British Library Electronic Table of Contents (United Kingdom)

ARIES-AT is a 1000MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of ...

2006-01-01

293

Options for passive containment cooling in next-generation nuclear plant designs  

International Nuclear Information System (INIS)

A design for passive cooling of large containment structures has progressed sufficiently to move forward into the detailed design stage necessary for plant construction. For such application, a safety analysis report has already been submitted to the US Nuclear Regulatory Commission. The design considers an annulus between the inner steel containment vessel and outer, thick-walled concrete shield building with chimney-like natural convection cooling driven only by a density gradient relative to the atmosphere. Air within the annulus is heated as internal containment temperature rises and heat is transferred through the steel containment shell. The resulting air density gradient between the annulus and the environment causes the heated air to rise, producing a natural convection flow through inlets in the shield building, past the steel shell, and out an exit chimney. Several options for enhancing passive heat removal of large containment ...

1993-11-01

294

Dynamics and developing of natural circulation cooling from vertical upflow and downflow conditions  

International Nuclear Information System (INIS)

Several research programs have been conducted to evaluate the capability of natural circulation cooling of reactors following a loss of cooling accident. Both experimental and RELAP5 simulation results were obtained for these studies in a facility with vertical heated tube(s) and a unheated bypass channel. The analytical results showed that, under a certain power level, a natural circulation pattern can be developed from both initial upflow and downflow conditions, and maintained for a significant cooling period. This power level, for the discussion of this paper, is defined as the natural circulation cooling (NCC) power limit. Two import factors, namely the pump coastdown rate and the initial flow direction, are examined in this paper. In the benchmark case, as compared to the experimental results, the RELAP5 simulation program accurately predicted the transient phenomena from forced convection through ...

1994-04-05

295

Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools: Repair, Service, and Corrective Actions  

Energy Technology Data Exchange (ETDEWEB)

The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB ...

1999-06-19

296

A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom  

Energy Technology Data Exchange (ETDEWEB)

A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a ...

2008-02-21

297

Venus surface power and cooling systems  

British Library Electronic Table of Contents (United Kingdom)

A mission to the surface of Venus would have high scientific value, but most electronic devices and sensors cannot operate at the 450degreeC ambient surface temperature of Venus. Power and cooling systems were analyzed for Venus surface operation. A radioisotope power and cooling system was designed to provide electrical power for a probe operating on the surface of Venus. For a mission duration of substantial length, the use of thermal mass to maintain an operable temperature range is likely impractical, and active refrigeration may be required to keep components at a temperature below ambient. Due to the high thermal convection of the high-density atmosphere, the heat rejection temperature was assumed to be at a 500degreeC radiator temperature, 50degreeC above ambient. The radioisotope S...

2007-01-01

298

Transformation kinetics and microstructures of Ti17 titanium alloy during continuous cooling  

International Nuclear Information System (INIS)

We have investigated the microstructure evolutions in the Ti17 near #beta# titanium alloy during heat treatments. The phase transformation has first been studied experimentally by combining X-ray diffraction analysis, electrical resistivity and microscopy observations. From a series of isothermal treatments, a IT diagram has been determined, which takes into account the different morphologies. Then, a Johnson-Mehl-Avrami-Kolmogorov (JMAK) model has been successfully used to describe the phase transformation kinetics during either isothermal or cooling treatments. Finally, the coupling of the JMAK model to the finite element software ZeBuLoN allowed us to investigate the evolution of the spatial distribution of the different morphologies during the cooling of an aircraft engine shaft disk after forging.

2007-03-15

299

Thermal-hydraulic analysis following a safety flapper valve's fault for a pool-type research reactor  

International Nuclear Information System (INIS)

One of the characteristic safety features of a pool type research reactor is a safety flapper valve. The valve enables natural convection cooling mechanism in one of the following events. (a) Opening flapper valve promote decay heat removal following reactor's shutdown. (b) Also the valve is gravity driven. There is a possibility that the valve fails to open when it is required to do so. In the present paper the cooling characteristics of the core are analyzed for this event. A steady state study was performed for 5 MW power and 18 FE following a reactor shutdown. It is shown that enough margin exists to assure adequate reactor core cooling should the safety flapper valve fails to open. (authors)

300

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative process is described for ...

1982-12-14

301

Thermal and radiation losses in a linear device  

Energy Technology Data Exchange (ETDEWEB)

An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high plug-plasma density ratio provides a ...

1980-11-01

302

System for cooling primary gas coolers using return water stabilized by means of ammonium sulfate  

Energy Technology Data Exchange (ETDEWEB)

Discusses scaling of closed systems for cooling coal gas from black coal coking. Scaling rate and factors that influence scaling are analyzed. Physical and chemical properties of scale buildup on the inner walls of pipe cooling systems are evaluated. Water pH value and its effects on scaling and solubility of chemical compounds that form scale are discussed. Use of ammonium sulfate for scale control is analyzed. Consumption rate of ammonium sulfate depends on ambient temperature, water pH value and chloride content in return water. Formulae for calculating optimum content of ammonium sulfates for scale control are derived. 3 refs.

1989-08-01

303

Study of phosphonate addition and hydrodynamic conditions on ordinary steel corrosion inhibition in simulated cooling water  

British Library Electronic Table of Contents (United Kingdom)

The effect of phosphonate anion (PHOS) on the corrosion of ordinary steel in simulated cooling water has been studied using weight loss, polarization curves and electrochemical impedance spectroscopy measurements. PHOS was studied in the concentration range from 7.5x10^-^5 to 10^-^3M. The results obtained reveal that PHOS perform excellently as corrosion inhibitor for ordinary steel in simulated cooling water. The inhibition efficiency of PHOS was increased with increasing both its concentration and water circulation velocity. These two factors seem to promote the adsorption of phosphorus and oxygen ions on the metal surface, leading to the formation of a protective layer with a greater charge transfer resistance and lower permeability. The inhibition efficiency decreased slightly with tem...

2010-01-01

304

Soft cooling with concrete: A simple system ensures a comfortable room climate; Sanfte Kuehlung aus Beton: Behagliches Raumklima mit einfachem System  

Energy Technology Data Exchange (ETDEWEB)

After cooling ceilings and source ventilation, simple air conditioning systems like thermal activation of concrete cores are gaining general acceptance. Parallel to this, ground source cooling systems are reducing the need for cold generation. Air conditioning systems of this type are favoured by producers of floor heating systems looking for a new market segment. [German] Nach Kuehldecken und Quellueftung gewinnen jetzt einfach aufgebaute Raumklimaanlagen, wie die thermische Betonkernaktivierung, immer mehr Anhaenger. Parallel dazu werden Verfahren zur Erdkaeltenutzung entwickelt, die den Anteil kuenstlich erzeugter Kaelte weiter zurueckdraengen. Forciert wird diese Art der Klimatisierung insbesondere durch die Hersteller von Fussbodenheizungen, fuer die sich hier ein neues Marktsegment eroeffnet. (orig.)

1999-10-01

305

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

Energy Technology Data Exchange (ETDEWEB)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10{sup -4} M to 10{sup -1} M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhibitor.

2008-06-15

306

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

British Library Electronic Table of Contents (United Kingdom)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10-4M to 10-1M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhi...

2008-01-01

307

Safety considerations of active process water system shutdown for TAPP - 3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)

2005-12-01

308

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be cooled using a pair 1.5 W (at 4.2 K) pulse tube coolers.

2009-10-19

309

Process development for continuous crystallization of fat under laminar shear  

British Library Electronic Table of Contents (United Kingdom)

A novel continuous laminar shear structuring crystallizer with a suitable cooling system was designed and built. This is a new method to continuously crystallize edible fat in the desirable polymorphic form from the melt while being uniformly sheared.The machine consists of four main sections: Feed unit, shearing mechanism, cooling system and power unit. In each of these sections specific design considerations are taken into account which makes the process controllable and continuous. The shearing unit is made of two concentric cylinders. The internal cylinder is stationary and has a cooling system inside for temperature control. The outer cylinder rotates to produce a uniform shear in the sample fluid placed in the 1.5mm gap between the cylinders. The sample's feed rate is controlled whil...

2008-01-01

310

Post-operative hilotherapy in SMAS-based facelift surgery: A prospective, randomised, controlled trial  

British Library Electronic Table of Contents (United Kingdom)

Background: Ecchymosis, oedema, haematoma and pain after SMAS-based facelift surgery are all the direct result of the physical trauma of surgery and subsequent inflammatory response. Hilotherapy is a novel form of cryotherapy that purports to minimise these events through single-use face masks circulating cooled, sterile water. This study was performed to assess the validity of Hilotherapy in this population of patients. Methods: Over 14 weeks fifty consecutive patients were randomised to post-operative facial cooling with Hilotherapy or management with standard dressings alone, while fifteen subsequent, consecutive patients were randomised to cooling of one side of the face but not the other. Assessment of ecchymosis, oedema, haematoma and pain was performed independently by clinical staf...

2011-01-01

311

Natural convection cooling of the IFMIF target and test cell  

International Nuclear Information System (INIS)

The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.

2007-10-01

312

Liquid metal reactor cover gas purification and analysis in the USA  

International Nuclear Information System (INIS)

Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.

1986-09-24

313

Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation  

CERN Document Server

An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.

2010-01-01

314

Horizontal ground coupled heat pump: Thermal-economic modeling and optimization  

Energy Technology Data Exchange (ETDEWEB)

The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters with the climatic conditions, ...

2010-12-15

315

Helium-cooling in fusion power plants  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews different helium-cooled first wall and blanket designs; and compares the selection of structural materials. The authors found that the solid breeder, SiC-composite material option generates the lowest amount of induced radioactivity and afterheat and has the highest temperature capability. When combined with the direct cycle gas turbine system, it has the potential to be the most economical fusion system and can compete with advanced fission reactors. When compared to martensitic steel and V-alloy, SiC-composite is the least developed of these three structural materials, a focused development effort will be needed. Fundamental research has begun in addressing the issues of optimized composite materials, irradiation effects, leak tightness and low activation braze materials. Development of helium-cooled high heat flux components and further development of the direct cycle gas turbine system will also be needed.

1994-11-01

316

Heat and fluid flow during the formation of metallic glasses by splat cooling  

Science.gov (United States)

A model is presented for heat and fluid flow during hammer and anvil splat cooling. Predictions are made for the effects of superheat and hammer speed on splat thickness, cooling rate, and subsequent glass formation. The regime of Newtonian heat flow is extended well beyond the previously accepted limiting value of Nusselt number. Measurements of the structure, stability, and thickness of Fe{sub 80}B{sub 20} and Pd{sub 80}Si{sub 20} hammer and anvil splats qualitatively confirm the model prediction. Variations of superheat in shock tube splats produced similar trends to those observed in the hammer and anvil device. In an attempt to vary the equivalent of hammer speed in a shock tube device, an orifice producing a supersonic shock wave was utilized. Significant splat flake thickness reductions resulted as compared to subsonic orifices.

317

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

318

Effect of convective wall currents on the air quality of source ventilation. Einfluss konvektiver Wandstroemungen auf die Luftqualitaet bei Quellueftung  

Energy Technology Data Exchange (ETDEWEB)

With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)

1993-07-01

319

Cooling/heating augmentation during turbine startup/shutdown using a seal positioned by thermal response of turbine parts and consequent relative movement thereof  

Energy Technology Data Exchange (ETDEWEB)

In a turbine rotor, a thermal mismatch between various component parts of the rotor occurs particularly during transient operations such as shutdown and startup. A thermal medium flows past and heats or cools one part of the turbine which may have a deleterious thermal mismatch with another part. By passively controlling the flow of cooling medium past the one part in response to relative movement of thermally responsive parts of the turbine, the flow of thermal medium along the flow path can be regulated to increase or reduce the flow, thereby to regulate the temperature of the one part to maintain the thermal mismatch within predetermined limits.

2000-01-01

320

Containment closure time following loss of cooling under shutdown conditions of YGN units 3 and 4  

Energy Technology Data Exchange (ETDEWEB)

The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling. The thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior. From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. These data provide useful information to the abnormal procedure to cope with the event. 6 refs., 7 figs., 2 tabs. (Author)

1998-12-31

321

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

322

Combining satellite data and models to estimate cloud radiative effect at the surface and in the atmosphere  

British Library Electronic Table of Contents (United Kingdom)

Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...

2011-01-01

323

Characterizing the time variability in magnetized neutrino--cooled accretion disks: signatures of the gamma-ray burst central engine  

CERN Document Server

The central engine of Gamma Ray Bursts is hidden from direct probing with photons mainly due to the high densities involved. Inferences on their properties are thus made from their cosmological setting, energetics, low-energy counterparts and variability. If GRBs are powered by hypercritical accretion onto compact objects, on small spatial scales the flow will exhibit fluctuations, which could in principle be reflected in the power output of the central engine and ultimately in the high energy prompt emission. Here we address this issue by characterizing the variability in neutrino cooled accretion flows through local shearing box simulations with magnetic fields, and then convolving them on a global scale with large scale dynamical simulations of accretion disks. The resulting signature is characteristic, and sensitive to the details of the cooling mechanism, providing in principle a discriminant for GRB central engine properties.

2010-01-01

324

COSY synchrotron and storage ring for medium energy physics  

Energy Technology Data Exchange (ETDEWEB)

At present the cooler synchrotron COSY a synchrotron and storage ring for medium energy physics is being commissioned at Juelich. The construction of the ring was finished during September 1992. The cooler ring will deliver protons in the momentum range from 270 to 3300 MeV/c. The phase density of the circulating protons will be increased with electron cooling at injection and with stochastic cooling at momenta between 1500 and 3300 MeV/c. High luminosity internal experiments as well as high resolution external experiments will be possible. Details of the lattice, to match the different ion optical requirements for cooling, acceleration, internal experiments and ultra-slow extraction will be discussed. An overview of the performance of the ion sources, the injector cyclotron, the ring, the injection beamline are given. The realization status of the extraction beamlines to the external experimental area is given. The ...

1993-01-01

325

Building design using the energy nomographs  

Energy Technology Data Exchange (ETDEWEB)

Today's building industry is promoting the use of renewable sources of energy to heat, cool, and illuminate commercial buildings. Societies such as the International Solar Energy Society sponsor conferences such as this one to share knowledge and experience in the area of solar energy. However, the technologies presented here assume a need for heating, cooling or illumination. A simple technique is presented for determining the actual heating, cooling, and lighting requirements for commercial buildings, and for reducing those requirements through proper building design before applying solar technologies. The energy nomographs are a graphic energy design tool developed to aid designers in making cost effective decisions about energy alternatives early in the design process. Reducing loads at this point can help reduce the expense of a passive or active solar system which is usually sized to meet a certain percentage ...

1983-06-01

326

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

327

The German uranium miners cohort study (Wismut cohort), 1946-2003. Technical report  

International Nuclear Information System (INIS)

From 1946 - 1990, i.e. from shortly after the end of World War II and the rise of the cold war until the German reunification, there had been extensive uranium mining both in Saxony and Thuringia, which formed the southern parts of the former German Democratic Republic. Mining activities started in Saxony in the Ore Mountains (German: Erzgebirge). Mining was conducted by a Soviet, since 1954 by a Soviet- German Incorporated Company named Wismut. It is estimated that about 400,000 persons may have worked in this time period with the company, most of them underground or in uranium ore processing facilities. In the early years, exposure to radiation and dust was particularly high for underground workers. After introduction of several ventilation measures and wet drilling from 1955 onwards, the levels of exposures to the various agents steadily decreased. After German reunification, it was decided by the German Federal Ministry for the Environment to save health data ...

328

Relative correlation of Jet-REMPI monitoring with adsorption tube sampling followed by TDS-CIS-GC/MS  

Energy Technology Data Exchange (ETDEWEB)

During earlier work rapid and highly sensitive Jet-REMPI (resonance-enhanced multiphoton ionization) mass spectrometry was applied for monitoring the effluent from thermal treatment of a filter dust during a de novo test under laboratory conditions. The sample, from ESP-Field 2 of an iron ore sintering plant, was already loaded with dioxins ({sigma}PCDD/F = 132 ng/g), their precursors (PCBz, PCPh) and other products of incomplete combustion. Heating filter dust in a temperature window 200-350 C under a flow of air results in further formation of these pollutants. As described elsewhere, on-line detection was mostly carried out using a non-selective ionization mode, to measure a wide range of compounds simultaneously. The changes of output suggest that the reaction products increase in chlorination level with time. Another explanation is that higherchlorinated compounds appear later as a consequence of lower volatility and stronger adsorption. ...

2004-09-15

329

Probing the Early Stages of Low-Mass Star Formation in LDN 1689N: Dust and Water in IRAS 16293-2422A, B, and E  

CERN Document Server

We present deep images of dust continuum emission at 450, 800, and 850 micron of the dark cloud LDN 1689N which harbors the low-mass young stellar objects (YSOs) IRAS 16293-2422A and B (I16293A and I16293B) and the cold prestellar object I16293E. Toward the positions of I16293A and E we also obtained spectra of CO-isotopomers and deep submillimeter observations of chemically related molecules with high critical densities. To I16293A we report the detection of the HDO 1_01 - 0_00 and H2O 1_10 - 1_01 ground-state transitions as broad self-reversed emission profiles with narrow absorption, and a tentative detection of H2D+ 1_10 - 1_11. To I16293E we detect weak emission of subthermally excited HDO 1_01 - 0_00. Based on this set of submillimeter continuum and line data we model the envelopes around I16293A and E. The density and velocity structure of I16293A is fit by an inside-out collapse model, yielding a sound speed of a=0.7 km/s, an age of t=(0.6--2.5)e4 yr, and a ...

2004-01-01

330

Health hazard evaluation report No. HHE-80-033-815, Asarco, Inc. , Hayden, Arizona  

Energy Technology Data Exchange (ETDEWEB)

Worker exposures to arsenic (7440382) (As), cadmium (7440439) (Cd), copper (7440508) (Cu), lead (7439921) (Pb) and sulfur-dioxide (7446095) (SO2) were surveyed at ASARCO, Incorporated (SIC-3331) in Hayden, Arizona on April 23 and 24, 1980. The evaluation was requested by an authorized representative of the United Steel Workers, Local 886, on behalf of an unspecified number of workers. Personal and area air samples were collected in the pug mill department, and workers were tested for blood Pb and urinary As concentrations. All four personal samples for As exceeded the OSHA standard of 10 micrograms per cubic meter, one sample exceeded the Cu dust standard of 1 milligram per cubic meter (mg/cu m), and one sample exceeded the Pb standard of 50 micrograms per cubic meter. Exposures to Cd fume, Cd dust, and SO2 were below the respective OSHA standard of 0.2mg/cu m, 1.0mg/cu m, and 5 parts per million. One worker had a urinary As concentration that ...

1981-02-01

331

EVIDENCE FOR EVOLUTION AMONG PRIMORDIAL DISKS IN THE 5 Myr OLD UPPER SCORPIUS OB ASSOCIATION  

International Nuclear Information System (INIS)

Moderate-resolution, near-infrared spectra between 0.8 and 5.2 #mu#m were obtained for 12 late-type (K0-M3) disk-bearing members of the #approx#5 Myr old Upper Scorpius OB association using SpeX on the NASA Infrared Telescope Facility. For most sources, continuum excess emission first becomes apparent between #approx#2.2 and 4.5 #mu#m and is consistent with that produced by single-temperature blackbodies having characteristic temperatures ranging from #approx#500 to 1300 K. The near-infrared spectra for 5 of 12 Upper Scorpius sources exhibit Pa#gamma#, Pa#beta#, and Br#gamma# emission, indicators of disk accretion. Using a correlation between Pa#beta# and Br#gamma# emission line luminosity and accretion luminosity, mass accretion rates ( M-dot ) are derived for these sources that range from M-dot = 3.5x10"-"1"0 to 1.5 x 10"-"8 M_s_u_n yr"-"1. Merging the SpeX observations with Spitzer Space Telescope mid-infrared (5.4-37.0 #mu#m) spectroscopy and 24 and 70 #mu#m broadband photometry, ...

2010-11-01

332

Turbine air intake treatment  

Energy Technology Data Exchange (ETDEWEB)

Gas turbine component protection remains essential but environmental regulations emphasize the gas-turbine efficiency. Heating and cooling are features often integrated into the GI air intake packages to provide the optimum operating conditions. This paper describes modern inlet air treatment systems and discusses their effectiveness. (author)

1999-07-01

333

Toxicity of radioactive wastes generated from PEACER spent fuel  

Energy Technology Data Exchange (ETDEWEB)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially {sup 90}Sr and {sup 137}Cs are dominant contributor nuclides until 30 years and especially {sup 90}Sr and {sup 137}Cs have the highest activity and decay heat than other LLFP. In this study, recovery of {sup 90}Sr and {sup 137}Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 ...

2003-10-01

334

Toxicity of radioactive wastes generated from PEACER spent fuel  

International Nuclear Information System (INIS)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 after 1000 years ...

2003-10-01

335

Toxicity of Radioactive Wastes Generated from PEACER in Korea  

International Nuclear Information System (INIS)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyro-processing. In the assessment of long-lived fission products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02 E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26 E+05 after 100 years cooling, 1.97 E+04 after 300 years cooling, 9.52 E+03 after 1000 years ...

2006-06-04

336

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive waste water and low temperature cooling ...

337

The influence of the explosion of the conductor of an electric cable on the dielectric properties of the polymer insulator  

British Library Electronic Table of Contents (United Kingdom)

The electric explosion of a conductor being part of an electric cable is studied. It is ascertained that the electric properties of a polymeric dielectric depend nonlinearly on the maintenance of the ultradisperse metal filler. In the course of the numerous heating-cooling processes of an insulator, a streamlining of the structure of a polymeric composite occurs.

2010-01-01

338

Telephone, mail, and personal questionnaires for data collection. [For heating and cooling  

Energy Technology Data Exchange (ETDEWEB)

Forms used in conducting a national survey about solar energy are presented. Forms for representatives from the domestic, commercial, and industrial sectors, owners and non-owners of solar equipment, are shown. Participants were to be contacted by telephone, mail, and personal visits. (MCW)

1980-02-20

339

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system besides the magnets and control dewar; (3) the control dewar and ...

1980-03-01

340

Study of the Energy Efficiency of the Melting Unit at the Rockwool Company Mineral Wool Process in Skoevde, Sweden.  

Science.gov (United States)

The melting unit, consisting of a water-cooled cupola furnace, afterburner, heat exchanger, air preheater, consumes most of the supplied energy in the rockwool process. The report maps the energy flows and defines factors of merit according to thermodynam...

1979-01-01

341

Simplified procedure for sizing and analyzing thermal energy storage in commercial and institutional buildings and generation of plots for North Carolina  

Energy Technology Data Exchange (ETDEWEB)

The objective of the project was to provide a readily understandable and usable methodology for preliminary analysis of the economic benefit that can accrue from the use of thermal energy storage for building heating and cooling. The procedure was to be capable of providing an estimate of cooling plant and storage size, as well as the monthly savings that can be saved. The research focused on the development of a procedure for a limited class of commercial and institutional buildings in North Carolina. A simplified procedure for analyzing the potential for using thermal energy storage (TES) in such buildings in North Carolina was developed. The procedure developed consists of charts and nomographs that can be used for estimating the size of TES systems, and for estimating the monthly demand savings. The monthly demand savings can be combined with the applicable rate schedule to determine the annual cost savings. An overview of the procedure and ...

1981-06-30

342

Precipitation during controlled cooling of magnesia-partially-stabilized zirconia  

Energy Technology Data Exchange (ETDEWEB)

A study has been made of the precipitation and growth processes which occur during cooling from solution treatment and under isothermal hold conditions in a magnesia-partially-stabilized zirconia alloy. Three types of precipitate have been identified which develop during cooling or during isothermal hold treatments just above and below the eutectoid temperature. These precipitate forms are termed (i) primary, (ii) large random, and (iii) secondary. Further precipitation, slow growth of existing precipitates, and subeutectoid decomposition result when an additional 1100/sup 0/C aging treatment is given to the previously cooled material. It is shown that type (iii) secondary precipitates from rapidly within the temperature range of 1300/sup 0/ to 1375/sup 0/C. The secondary precipitates are largely responsible for the improved room-temperature strength properties of the heat-treated samples. The formation and effects on ...

1986-07-01

343

Precipitation during controlled cooling of magnesia-partially-stabilized zirconia  

International Nuclear Information System (INIS)

A study has been made of the precipitation and growth processes which occur during cooling from solution treatment and under isothermal hold conditions in a magnesia-partially-stabilized zirconia alloy. Three types of precipitate have been identified which develop during cooling or during isothermal hold treatments just above and below the eutectoid temperature. These precipitate forms are termed (i) primary, (ii) large random, and (iii) secondary. Further precipitation, slow growth of existing precipitates, and subeutectoid decomposition result when an additional 1100"0C aging treatment is given to the previously cooled material. It is shown that type (iii) secondary precipitates from rapidly within the temperature range of 1300"0 to 1375"0C. The secondary precipitates are largely responsible for the improved room-temperature strength properties of the heat-treated samples. The formation and effects on mechanical ...

344

Policy implications of funding DOE's K Reactor Cooling tower Project  

Energy Technology Data Exchange (ETDEWEB)

This report has reviewed the construction of a cooling tower for the K reactor at the DOE Savannah River Site in Aiken, South Carolina. It has been found that the cooling tower would prevent further destruction of cypress and tupelo trees, would maintain a more consistent flow from site streams, and would allow earlier recovery of stream corridors inside a portion of the site. About 630 acres of wetlands have already been affected by the hot water discharged by the K reactor during the past 35 years. GAO believes that about 10 to 12 acres of additional damage would be prevented by the tower for every year the reactor is operated, and if current plans for re-start and retirement of the reactor are followed, less than 100 acres would be preserved. As requested, GAO also identified an example of a project that could be funded as compensation to the public for the damage the K reactor would do if Congress exempted it from the Clean Water Act and ...

1989-10-01

345

On the natural convection cooling in HANARO (Hi-flux Advanced Neutron Application Reactor). Experiment and RELAP5/KMRR simulation  

International Nuclear Information System (INIS)

The natural circulation experiments were conducted to confirm the cooling capability and the flow characteristics of the natural convection in the HANARO (Hi-flux Advanced Neutron Application Reactor). The tests were done at the power levels of 2%, 3% and 4% (1.2MW_t_h) of full power. The flow rates and temperatures at various locations of the primary and secondary cooling loops were measured at each power level. The temperature distributions in the chimney and the pool were also obtained. Through tests, the flow paths of the natural circulation and the cooling capability of the reactor were confirmed as designed. In addition, the simulation for the natural circulation tests was made by using RELAP5/KMRR, which was modified from RELAP5/MOD2 for applying to the HANARO conditions. The simulation results show that RELAP5/KMRR gives reasonable predictions for the flow rate and the coolant temperature during natural circulation ...

346

Natural convection cooling of a close-packed array of AGR fuel pins surrounded by graphite debris  

International Nuclear Information System (INIS)

Certain postulated faults during refuelling of AGRs may give rise to compacted fuel and graphite sleeve debris. This debris must be maintained below some safe limiting temperature. As part of a programme to assess the benefits of natural convection in cooling such debris in a region experiencing no forced cooling, a simple geometry incorporating typical debris has been studied both experimentally and by prediction. The experiment comprised an array of electrically heated fuel rods mounted co-axially in a closed cylindrical vessel and surrounded by fragments of graphite. The vessel was cooled on its cylindrical surface, the ends being insulated. Rods and vessel wall were thermocoupled. Tests covered a range of temperature and pressures in both CO_2 and N_2. Significant natural convection heat removal was demonstrated, particularly at high pressure. Predictions utilising the PHOENICS code agreed well with measured ...

347

Natural circulation cooling in US Pressurized Water Reactors  

International Nuclear Information System (INIS)

This document is a synthesis of data and analysis concerning natural circulation cooling in US Pressurized Water Reactors during off-normal operation and accident transients. Its objective is the integration of important research findings concerning PWR natural circulation phenomena into a single reference document. Sources of information include the Nuclear Regulatory Commission, reactor vendors, utility sponsored research groups, utilities, national laboratories, research reports, meeting papers, archival literature, and foreign sources. Three modes of natural circulation are discussed: single-phase, two-phase, and reflux/boiling condensation. General characteristics, analytical expressions, noncondensible gas effects, secondary effects, and nonuniform flow are described with regard to each of the natural circulation modes. Plant operational data, tests in scaled experimental facilities, and analysis with thermal hydraulic system codes have demonstrated the ...

348

Mound Facility explosives incinerator  

Energy Technology Data Exchange (ETDEWEB)

The design and performance of small incinerators used at the Mound Laboratory for the disposal of explosives are described. These units, which cost less than $1000 each, are about the size of a 55-gal drum, have water jackets for cooling, and have provided a flexible, efficient, and clean burning explosives disposal unit. (LCL)

1980-01-01

349

Measured impact of neighborhood tree cover on microclimate  

Energy Technology Data Exchange (ETDEWEB)

In this paper we present results of our investigation into the relationship between urban microclimate and the local density of tree cover as measured in Sacramento, California. These results were obtained through analysis of data collected in a two-month long monitoring program with automatic weather stations installed at 15 residential locations throughout the city. Measured wind speeds showed a highly negative correlation with respect to tree cover. Daily peak air temperatures showed significant variation often differing from site to site by 2 to 4{degrees}C ({approx}3.5 to 7{degrees}F). A complex interaction between several competing factors is discussed leading to the conclusion that additional tree cover may actually increase urban air temperatures on synoptically cool days. It is suggested that this does not have a significant adverse affect in terms of overall summer urban cooling load. This is supported by an integrated analysis of the ...

1992-08-01

350

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...

1992-01-01

351

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...

1992-11-15

352

Heating and cooling with geothermal energy: trends and accomplishments; Solutions de chauffage et de climatisation utilisant l`energie geothermique: tendances et realisations  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet the heating and cooling needs of public buildings at considerable cost reductions, besides offering ...

1996-03-01

353

Heat Transfer Augmentation in Turbulent Impinging Jets.  

Science.gov (United States)

Heating and cooling by impinging jets is widely used in various engineering applications, due to the high heat transfer rates prevailing in the vicinity of the stagnation point. The authors have been able to utilize acoustically excited turbulence for the...

1979-01-01

354

Gas-Cooled Fast Breeder Reactor preliminary safety information document, Amendment 9. GCFR fuel cladding PC-5 (faulted) temperature limit  

Energy Technology Data Exchange (ETDEWEB)

Information is presented concerning GCFR design and limiting faulted events; selection of PC-5 temperature limit; and verification test programs.

1980-02-01

355

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...

1981-05-01

356

Experimental Study of a Method of Mechanical Augmentation of Convective Heat Transfer Coefficients in Air.  

Science.gov (United States)

Scraped-surface heat transfer augmentation is proposed as a possible technique for use in improved air-cooling designs. Although it has been in common use with liquids, the technique has apparently never been used with gases. An experimental investigation...

1974-01-01

357

Experience with fully operational solar-driven 10-ton LiBr/H2O single-effect absorption cooling system in Thailand  

British Library Electronic Table of Contents (United Kingdom)

A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...

2008-01-01

358

Evaluation of advanced technologies for power transformers. Final report  

Energy Technology Data Exchange (ETDEWEB)

The high insulating strength of certain gases, such as sulfur hexafluoride, when used at high pressure, suggests that there may be advantages to compressed gases as the insulating fluid in power transformers. However, simply exchanging the oil for compressed gas in an otherwise conventional transformer design will not yield a significant overall advantage. Compressed gases present the engineer with properties which are quite different from mineral oil. If gases are to be used as the major insulating fluid in power transformers, then virtually all aspects of the insulation and cooling of the apparatus must be reconsidered, affording an opportunity to introduce new design concepts, new materials, and new construction techniques. In this program, the feasibility of using the following principal design concepts has been explored: sheet conductors for the windings; a system of sealed, self-contained, annular cooling ducts containing circulating ...

1981-01-01

359

Emergency core cooling device  

International Nuclear Information System (INIS)

Purpose: To effectively cool the reactor core in a steam atmosphere by upwardly directing several of spray nozzles attached to a ring header thereby increasing the flying distance of the spray. Constitution: Ring headers in two upper and lower stages are disposed above the outer circumference of a reactor core and each of the ring headers is mounted with spray nozzles. Among the spray nozzles, at least several nozzles mounted to the ring header at the lower stage are directed such that the center axis for each of the nozzle is raised above the horizontal axis and other several nozzles are mounted with the nozzle center axis directed downwardly from the horizontal axis. Accordingly, even if collapsing phenomenon occurs in the jetting stream due to the condensation in the steams that forms the operation atmosphere of the reactor core spray cooling device, a sufficient amount of emergency cooling water can be distributed over ...

1983-03-09

360

ELECTRONIC COMPONENT COOLING ALTERNATIVES: COMPRESSED AIR AND LIQUID NITROGEN  

Science.gov (United States)

The goal of this study was to evaluate topics used to troubleshoot circuit boards with known or suspected thermally intermittent components. Failure modes for thermally intermittent components are typically mechanical defects, such as cracks in solder paths or joints, or broken b...

361

Cylindrical stretched flame  

Energy Technology Data Exchange (ETDEWEB)

For sufficiently cool remote gases, the cylindrical stretched flame shows classical ignition-extinction behavior. For remote gas temperatures close to the adiabatic flame temperature, the flame response is qualitatively different, with negative flame speed solutions which may be physically accessible.

1984-06-01

362

Conceptual design of a medium scale lead-bismuth cooled fast reactor  

International Nuclear Information System (INIS)

To seek for a promising concept of a heavy liquid metal coolant (HLMC) fast reactor plant, Japan Nuclear Cycle Development Institute and the electric utilities conducted conceptual design study on various types of plant concepts and compared these concepts based on technical feasibility and economical perspective. A comparative design study is performed on Lead-Bismuth cooled reactors with forced and natural convection cooling. Eliminating an intermediate cooling system makes the heat transport system simple and can decrease the amount of the weight of NSSS. Based on the estimation of the amount materials, the plant internal load etc., a construction cost of these plants are evaluated approximately 2/3 times of that of LWRs at present. And, the nitride fuel makes breeding ratio of 1.2 with 150 GWd/t of burnup. The results of unprotected event analyses such as UTOP and ULOF show that both of concepts have possible features ...

2003-09-15

363

Conceptual design for accelerator-driven sodium-cooled sub-critical transmutation reactors using scale laws  

Energy Technology Data Exchange (ETDEWEB)

The feasibility study on conceptual design methodology for accelerator-driven sodium-cooled sub-critical transmutation reactors has been conducted to optimize the design parameters from the scale laws and validates the reactor performance with the integrated code system. A 1000 MWth sodium-cooled sub-critical transmutation reactor has been scaled and verified through the methodology in this paper, which is referred to Advanced Liquid Metal Reactor (ALMR). A Pb-Bi target material and a partitioned fuel are the liquid phases, and they are cooled by the circulation of secondary Pb-Bi coolant and by primary sodium coolant, respectively. Overall key design parameters are generated from the scale laws and they are improved and validated by the integrated code system. Integrated Code System (ICS) consists of LAHET, HMCNP, ORIGEN2, and COMMIX codes and some files. Through ICS the target region, the core region, and ...

1998-12-31

364

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that ...

2002-01-01

365

Chalk Point Cooling Tower Project: Drift Salinity Experiments.  

Science.gov (United States)

Results of feasibility experiments for determining the mineral content of individual stains on special Sensitized Paper are presented. The stains were formed on the paper by the impaction of laboratory generated salt water droplets. Of the techniques exam...

1979-01-01

366

Chalk Point Cooling Tower Project: Chalk Point Meteorological Station Report. Volume II.  

Science.gov (United States)

This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...

1979-01-01

367

Biogenic carbon and anthropogenic pollutants combine to form a cooling haze over the southeastern United States  

UK PubMed Central (United Kingdom)

Remote sensing data over North America document the ubiquity of secondary aerosols resulting from a combination of primary biogenic and anthropogenic emissions. The spatial and temporal distribution...Full Text Available

2009-06-02

368

Air conditioning of future small urban electric cars by thermoelectricity  

Energy Technology Data Exchange (ETDEWEB)

Air conditioning of urban electric cars by Peltier effect is simulated. Advantages (noise, simplicity of construction and of regulation, good heating performances...) and disadvantages (cooling performances lower than actual compressors, actual costs...) are presented. (A.B.). 8 refs., 5 figs.

1994-01-01

369

A statistically-selected Chandra sample of 20 galaxy clusters -- II. Gas properties and cool-core/non-cool core bimodality  

CERN Document Server

We investigate the thermodynamic and chemical structure of the intracluster medium (ICM) across a statistical sample of 20 galaxy clusters analysed with the Chandra X-ray satellite. In particular, we focus on the scaling properties of the gas density, metallicity and entropy and the comparison between clusters with and without cool cores (CCs). We find marked differences between the two categories except for the gas metallicity, which declines strongly with radius for all clusters (Z ~ r^{-0.31}), outside ~0.02 r500. The scaling of gas entropy is non-self-similar and we find clear evidence of bimodality in the distribution of logarithmic slopes of the entropy profiles. With only one exception, the steeper sloped entropy profiles are found in CC clusters whereas the flatter slope population are all non-CC clusters. We explore the role of thermal conduction in stabilizing the ICM and conclude that this mechanism alone is sufficient to balance ...

2009-01-01

370

A rare case of neuroleptic malignant syndrome presenting with serious hyperthermia treated with a non-invasive cooling device: a case report  

UK PubMed Central (United Kingdom)

IntroductionA rare side effect of antipsychotic medication is neuroleptic malignant syndrome, mainly characterized by hyperthermia, altered mental state, haemodynamic dysregulation,...Full Text Available

371

A New Efficient Method of Topical Cooling and Rewarming of the Myocardium  

UK PubMed Central (United Kingdom)

Profound myocardial hypothermia (below 17° C, and more often around 12° C) is imperative in myocardial protection while the aorta is cross-clamped. Based on our experience in...Full Text Available

1985-12-01

372

10:10 - progress on our pledges | Environment | The Guardian  

Wastenet

... At the Vintage at Goodwood festival we're curating this summer, we intend to demonstrate how sustainability can be cool without being hippy in 2010. It really can - I'm the living embodiment of that . . .\\

373

The onset conditions of enhancement of ice accumulation associated with heat-conducting plates located perpendicularly to heat-transfer surfaces; Part 1: Analysis for still water  

Energy Technology Data Exchange (ETDEWEB)

An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.

1994-07-01

374

The natural convection cooling with vaporizing deuterium for the horizontally arranged cold neutron source of the HFR - Grenoble  

International Nuclear Information System (INIS)

Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.

1991-08-01

375

Reconsidering the site requirements for NPP on Olt River  

International Nuclear Information System (INIS)

Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation water cooling ...

2009-10-12

376

Production of blast furnace coke via novel briquetting system  

Science.gov (United States)

A method of making high strength coke briquettes suitable for use as blast furnace coke comprising, (A) providing coal, (B) heating the coal at a temperature at or above the softening point of the coal to form partially carbonized char, (C) cooling the partially carbonized char below the softening point of the coal, (D) mixing the cooled partially carbonized char and tar to form a mixture of tar and partially carbonized char, (E) briquetting the mixture of tar and partially carbonized char to form briquettes of tar and partially carbonized char, (F) calcinating the briquettes to form high strength briquettes.

1982-12-07

377

Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.

2002-08-01

378

Natural convection cooling of circumferentially finned transport casks  

International Nuclear Information System (INIS)

It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.

1983-12-01

379

More iPhone Cool Projects  

CERN Document Server

Everyone is developing iPhone applications, and it's clear why. The iPhone is the coolest mobile device available, and the App Store makes it simple to get an application out into the unstoppable iPhone app market. With hundreds of thousands of app developers entering the game, it's crucial to learn from those who have actually succeeded. This book shows you how some of the most innovative and creative iPhone application developers have developed cool, best-selling apps. Not only does every successful application have a story, but behind every great app is excellent code. In this book, you'll

2010-01-01

380

Loss of flow accident analysis of a water-cooled fusion reactor  

International Nuclear Information System (INIS)

Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)

2003-08-25

381

Leak sealing on ancillary cooling circuits of CANDU reactors  

International Nuclear Information System (INIS)

This paper discusses the remote plugging of leaks in inaccessible pipework, with main reference to small leaks which frequently appear in ancillary cooling water circuits of nuclear reactors. Initially developed to cure problems of the pre-stressed concrete pressure vessels of UK reactors, the ZORIC sealant has been used to repair leaking biological shield pipework on six CANDU reactors. ZORIC is based on a water-soluble epoxy resin and an aqueous suspension of a refined mineral clay. This paper describes the evolution of the sealant, the qualification and testing program, and their application to CANDU reactor systems. 2 refs., 6 figs.

1992-11-22

382

Heating and cooling  

Energy Technology Data Exchange (ETDEWEB)

Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.

1998-05-01

383

Fast starting cold shield cooling circuit for superconducting generators  

Energy Technology Data Exchange (ETDEWEB)

An apparatus is provided for rapidly restarting the flow of coolant through the cold electromagnetic shield of a superconducting rotor following a thermal transient episode. A vortex diode inhibits coolant flow in the undesirable reverse direction and encourages the reestablishment of a normal thermosyphon cooling loop flow quickly following the termination of a thermal transient such as that caused by transmission line faults. The present invention requires no moving parts and may therefore be permanently sealed in the superconducting rotor without risk of costly repair efforts caused by components failure.

1982-12-21

384

Experiments to investigate the effects of radiative cooling on plasma jet collimation  

CERN Document Server

Preliminary experiments have been performed to investigate the effects of radiative cooling on plasma jets. Thin (3 um - 5 um) conical shells were irradiated with an intense laser, driving jets with velocities > 100 km/s. Through use of different target materials - aluminium, copper and gold - the degree of radiative losses was altered, and their importance for jet collimation investigated. A number of temporally resoved optical diagnostics was used, providing information about the jet evolution. Gold jets were seen to be narrower than those from copper targets, while aluminium targets produced the least collimated flows.

2010-01-01

385

Experimental study of beam optics and energy recovery for high-energy electron cooling device  

International Nuclear Information System (INIS)

The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.

386

Development of commercial high temperature gas-cooled reactor in China  

Energy Technology Data Exchange (ETDEWEB)

The high temperature gas-cooled test reactor HTR-10 achieved the first criticality in last December in Institute of Nuclear Energy Technology of Tsinghua University in Beijing. Fuji Electric and Nissho Iwai have a cooperative information exchange agreement on the commercialization of the HTGRs with INET, and held an information exchange meeting in last March in INET. INET has started a study on the modification of the HTR-10 to couple with gas turbine system and a pre-feasibility study on the commercial HTGR under the cooperation with China State Power Company. The experiences and abilities of INET in the field of the HTGR and the aggressive plan for commercialization of the HTGR in China are summarized and discussed. (author)

2001-07-01

387

Development of a helium-cooled divertor concept: design-related requirements on materials and fabrication technology  

International Nuclear Information System (INIS)

Within the framework of the EU power plant conceptual study (PPCS), a modular He-cooled divertor concept with integrated pin array (HEMP) is being developed at the Forschungszentrum Karlsruhe. The design goal is to achieve a high heat flux of at least about 10-15 MW/m"2, which is proposed for a near-term reactor model like DEMO. The development and optimization of the divertor concept require a close link between the main issues: design, analyses, materials and fabrication technology, and experiments with feedbacks between them to be accounted for. Design-specific requirements on materials and fabrication issues will be discussed.

2004-08-01

388

Deterministic loading of individual atoms to a high-finesse optical cavity  

CERN Document Server

Individual laser cooled atoms are delivered on demand from a single atom magneto-optic trap to a high-finesse optical cavity using an atom conveyor. Strong coupling of the atom with the cavity field allows simultaneous cooling and detection of individual atoms for time scales exceeding 15 s. The single atom scatter rate is studied as a function of probe-cavity detuning and probe Rabi frequency, and the experimental results are in good agreement with theoretical predictions. We demonstrate the ability to manipulate the position of a single atom relative to the cavity mode with excellent control and reproducibility.

2007-01-01

389

Cogeneration and beyond: The need and opportunity for high efficiency, renewable community energy systems  

International Nuclear Information System (INIS)

The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.

2007-10-15

390

BNES materials conference a status review of alloy 800  

International Nuclear Information System (INIS)

Existing applications of Alloy 800 are summarized, with particular reference to its use in various types of reactor. The need for a co-ordinated research and development programme is stressed, and the variables to be explored are outlined. The papers relating to the problem of corrosion and cracking in water and steam are considered. the strength and ductility of Alloy 800 is considered. Finally, sections of the summary deal with the use of Alloy 800 for (a) sodium cooled fast reactor boiler tubes; (b) the high temperature gas cooled reactor; and (c) PWR steam generator tubes. (U.K.).

391

Thermal performance of phase change wallboard for residential cooling application  

Energy Technology Data Exchange (ETDEWEB)

Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the ...

1997-04-01

392

Natural convection cooling of a vertical channel  

International Nuclear Information System (INIS)

An experimental program has been conducted to determine the feasibility of natural convection cooling of a reactor following a beyond-design-based accident. The particular application under consideration was the heavy-water new production reactor. The questions to be resolved include the verification that a natural convection cooling pattern would be established and the determination of the power limit for which convective cooling will occur for a significant period of time. In the experiment, the reactor configuration was simulated using small-diameter vertical heated tubes in parallel with a large-diameter bypass line. Following a loss-of-flow event, the flow in the bypass line will reverse direction and pass through the heated channel by means of natural convection. If, however, the channel power is too high, void formation will block the channel and prevent the reverse flow pattern from occurring. The test procedure ...

1993-11-14

393

Study on core cooling of hybrid safety system for next-generation PWR during LOCA  

International Nuclear Information System (INIS)

Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of noncondensable gas is presented. The integral thermal-hydraulic tests simulate the small LOCA ...

1995-04-23

394

Study on Control of Brain Temperature for Brain Hypothermia Treatment  

Science.gov (United States)

The brain hypothermia treatment is an attractive therapy for the neurologist because of its neuroprotection in hypoxic-ischemic encephalopathy patients. The present paper deals with the possibility of controlling the brain and other viscera in different temperatures from the viewpoint of system control. It is theoretically attempted to realize the special brain hypothermia treatment to cool only the head but to warm the body by using the simple apparatus such as the cooling cap, muffler and warming blanket. For this purpose, a biothermal system concerning the temperature difference between the brain and the other thoracico-abdominal viscus is synthesized from the biothermal model of hypothermic patient. The output controllability and the asymptotic stability of the system are examined on the basis of its structure. Then, the maximum temperature difference to be realized is shown dependent on the temperature range of the apparatus and also on ...

2003-01-01

395

Simulation of natural convection cooling phenomena for research reactors using the code PARET  

International Nuclear Information System (INIS)

This study deals with testing the capability of the code PARET to simulate natural convection cooling phenomena under different boundary conditions. In addition to applying and testing some new options related to simulation of the control rod movement and studying the reactivity effect of thermal expansion fuel elements. The experiments of the simple thermal hydraulic loop of Missouri university about natural cooling phenomena in two narrow paralled channels were used to validate the code. The study indicate good results regarding the distribution of coolant flux velocity and clad temperature. In particular the heat transfer coefficient of natural convection has been calculated in good agreement with the experiment. On the other hand, the core of MNSR reactor has been modelled to simulate the reactor dynamic behaviour under natural convection cooling conditions for different initial power level. The observed oscillation ...

396

Numerical analysis of a natural convection cooling system for radioactive canisters storage  

International Nuclear Information System (INIS)

This paper describes the use of numerical analysis for studying natural convection cooling systems for long term storage of heat producing radioactive materials, including special nuclear materials and nuclear waste. The paper explains the major design philosophy, and shares the experiences of numerical modeling. The strategy of storing radioactive material is to immobilize nuclear high-level waste by a vitrification process, convertion it into borosilicate glass, and cast the glass into stainless steel canisters. These canisters are seal welded, decontaminated, inspected, and temporarily stored in an underground vault until they can be sent to a geologic repository for permanent storage. These canisters generate heat by nuclear decay of radioactive isotopes. The function of the storage facility ventilation system is to ensure that the glass centerline temperature does not exceed the glass transition temperature during storage and the vault concrete temperatures ...

1995-02-01

397

Inherent safe heat removal in advanced medium-sized high-temperature reactors  

International Nuclear Information System (INIS)

One of the main points for the inherent safety of a pebble bed high temperature reactor (HTR) is to guarantee the safe removal of the after-heat in case of a break-down of all active cooling systems like heat-exchangers or liner-cooling. This will be necessary because it is well known today that graphite pebble bed fuel elements stay intact, if the accident temperature is below 1600 deg. C. Therefore the heat must be taken out of the reactor system by passive, natural law heat-transfer mechanism so that the maximum fuel temperature stays below the specified limit. Today medium-sized HTRs with a power of 750 MW_t_h and more (TGTR-300, HTR 500) reach temperatures of more than 2400 deg. C in small parts of the core in such hypothetical accidents. A possible way to realize the inherent safe heat removal in advanced medium-sized HTRs is to change the form of the core. Instead of employing the standard cylindrical geometry a plate shaped core should ...

1990-04-01

398

A cryocondensation pump for the DIII-D Advanced Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A cryocondensation pump was designed for the baffle chamber of General Atomics DIII-D tokamak and will be installed in the fall of 1992. The purpose of the pump is to study plasma density control by pumping the divertor. The pump is toroidally continuous, approximately 10 m long and located in the lower outer corner of the vacuum chamber of the machine. It consists of a 1 m{sup 2} liquid helium-cooled surface surrounded by a liquid nitrogen-cooled shield to limit the heat load on the helium-cooled surface. The liquid nitrogen-cooled surface is surrounded by a radiation/particle shield to prevent energetic particles from impacting and releasing condensed water molecules. A thermal enhancement coating was applied to the nitrogen shell to lower the maximum temperature of the shell. The coating is non-continuous to keep the toroidal electrical resistance high. The whole pump is supported off the ...

1992-03-01

399

WR 104: Are We Looking Down The Gun Barrel of a Future GRB?  

Science.gov (United States)

WR 104 is the prototype for a small but growing group of stars that present the remarkably striking appearance of pinwheels. High resolution images of WR 104 show the (apparently) face-on spiral turning with an 8 month period. The pinwheel is assumed to be composed of dust produced via colliding winds in a low-inclination WR+OB binary. These assumptions have been very successful in modeling the imaging, but remain largely untested by spectroscopy. Strong motivation for further study of this system has emerged. Recent theory suggests that some gamma-ray bursts (GRB's) are core-collapse supernovae viewed nearly pole-on. The WC class Wolf-Rayet star in WR 104 is the type of star thought to be a possible GRB progenitor. If the orbit (and thus stellar rotation axes) are pole-on, the effects on Earth's biosphere could be significant. Confrontation of the face-on colliding-wind binary model with eight years of spectroscopy, offering full phase coverage of WR 104, is ...

2009-01-01

400

Use of neutron activation analysis for the control of air pollution of Algiers; Utilisation de l'analyse par activation neutronique pour le controle de la pollution de l'air d'Alger  

Energy Technology Data Exchange (ETDEWEB)

The urban zone needs clean air to assure public health. To achieve this goal several filter samples were collected in different sites in Algiers city. Toxic elements such as: Na, Mg, Cl, Sc, Cr, Ti, V, Fe, Co, Cu, Zn, Se, Br, Ag, Sb, Ce, La, Hf, Ta and Hg have been measured in the filters using neutron activation analysis technique. Irradiation of filter samples and standards were carried out in Es-Salem reactor. The experimental procedure and the results are discussed. We noted during this work that the upper limit values for suspended dusts and the high concentrations for some toxic elements found are due to the weather conditions and intense road traffic around collecting sites. (authors)

2010-07-15

401

Time-Resolved Aerosol Collector for CCSEM/EDX Single Particle Analysis  

Energy Technology Data Exchange (ETDEWEB)

An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 Air Quality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the relative contribution of non-volatile particles such as ammonium ...

2003-01-02

402

The Origin of Life from Primordial Planets  

CERN Document Server

The origin of life and the origin of the universe represent two of the most important problems of science. Both are resolved by hydro-gravitational dynamics (HGD) cosmology (Gibson 1996, Schild 1996, Gibson 2009ab), which predicts frozen primordial hydrogen-helium gas planets in clumps as the dark matter of galaxies. Merging Earth-mass planets formed stars, moons and comets to incubate and cosmically seed the first life. Cometary panspermia (Hoyle and Wickramasinghe 1981, 1982; Wickramasinghe et al. 2009) occurs naturally by HGD mechanisms. Comets and moons are fragments from mergers of stardust covered frozen gas planets in their step-wise growth to star mass. Supernovae from stellar over-accretion of planets produce stardust (C, N, O, P etc.) chemical fertilizer. Planets collect this infected radioactive dust gravitationally, to provide liquid water domains in contact with life nutrients seeded with life prototypes. The first mutating, evolving, life from HGD ...

2010-01-01

403

The Local Environment of the FUor-like Objects AR 6A and 6B  

CERN Document Server

We present new 12CO J=3-2 and HCN J=3-2 molecular line maps of the region surrounding the young star AR 6 using the 15 metre James Clerk Maxwell Telescope. AR 6 was previously found to be a double source with both components exhibiting several characteristics of FU Orionis (FUor) eruptive variable stars. Our data indicates that AR 6, like FU Orionis itself, does not possess a CO outflow and likewise, does not show evidence for large amounts of molecular g as in its circumstellar environment. We conclude that from the near-IR to the sub-mm, AR 6 is similar to FU Orionis in several respects. We interpret the lack of significant dust and molecular gas in the circumstellar environment of AR 6, together with the large near-IR thermal excess, as evidence that the sources have exhausted their natal envelopes, that they have at least small hot circumstellar disks, and that they are more evolved than Class I protostars. This, in itself, suggests that, since FUor eruptions ...

2008-01-01

404

Terrestrial Planet Formation in Extra-Solar Planetary Systems  

CERN Document Server

Terrestrial planets form in a series of dynamical steps from the solid component of circumstellar disks. First, km-sized planetesimals form likely via a combination of sticky collisions, turbulent concentration of solids, and gravitational collapse from micron-sized dust grains in the thin disk midplane. Second, planetesimals coalesce to form Moon- to Mars-sized protoplanets, also called "planetary embryos". Finally, full-sized terrestrial planets accrete from protoplanets and planetesimals. This final stage of accretion lasts about 10-100 Myr and is strongly affected by gravitational perturbations from any gas giant planets, which are constrained to form more quickly, during the 1-10 Myr lifetime of the gaseous component of the disk. It is during this final stage that the bulk compositions and volatile (e.g., water) contents of terrestrial planets are set, depending on their feeding zones and the amount of radial mixing that occurs. The main factors that influence ...

2008-01-01

405

THE EVOLUTION OF CLOUD CORES AND THE FORMATION OF STARS  

International Nuclear Information System (INIS)

For a number of starless cores, self-absorbed molecular line and column density observations have implied the presence of large-amplitude oscillations. We examine the consequences of these oscillations on the evolution of the cores and the interpretation of their observations. We find that the pulsation energy helps support the cores and that the dissipation of this energy can lead toward instability and star formation. In this picture, the core lifetimes are limited by the pulsation-decay timescales, dominated by non-linear mode-mode coupling, and on the order of #approx =# few x 10"5-10"6 yr. Notably, this is similar to what is required to explain the relatively low rate of conversion of cores into stars. For cores with large-amplitude oscillations, dust continuum observations may appear asymmetric or irregular. As a consequence, some of the cores that would be classified as super-critical may be dynamically stable when oscillations are taken into account. Thus, ...

2010-09-20

406

Superfund Record of Decision (EPA Region 10): Commencement Bay Nearshore/Tideflats Site, operable unit 4, Ruston/North Tacoma Study Area, WA, June 1993  

Energy Technology Data Exchange (ETDEWEB)

This decision document presents the selected remedial action for the Ruston/North Tacoma Study Area, in Ruston and Tacoma, Washington. The EPA has divided the Commencement Bay/Nearshore Tideflats Superfund site into seven operable units (OU's) in order to facilitate the investigation, analysis, and cleanup of this very large site. Four of these OU's are associated with the Asarco smelter: OU 02 - Asarco Tacoma Smelter; OU 04 - Asarco Off-Property (Ruston/North Tacoma Study Area); OU 06 - Asarco Sediments; and OU 07 - Asarco Demolition. The remedy described in this ROD addresses OU 04 and involves the cleanup of arsenic and lead contaminated soils and slag in the Study Area, the residential community surrounding the smelter. This remedy will address the principal threat posed by conditions at the site, which is the ingestion of contaminated soil and dust.

1993-06-01

407

Structure and kinematics of edge-on galaxy discs - I. Observations of the stellar kinematics  

CERN Document Server

We present deep optical long-slit spectra of 17 edge-on spiral galaxies of intermediate to late morphological type, mostly parallel to their major axes and in a few cases parallel to the minor axes.The line-of-sight stellar kinematics are obtained from the stellar absorption lines using the improvedc ross-correlation technique. In general, the stellar kinematics are regular and can be traced well into the disc-dominated region. The mean stellar velocity curves are far from solid-body, indicating that the effect of dust extinction is not large. The line-of-sight stellar disc velocity dispersion correlates with the galaxy maximum rotational velocity, but detailed modeling is necessary to establish whether this represents a physical relation. In four spirals with a boxy- or peanut-shaped bulge we are able to detect asymmetric velocity distributions, having a common signature with projected radius in the mean line-of-sight velocity and the $h_{3}$ and $h_{4}$ curves. ...

2004-01-01

408

Stripping a debris disk by close stellar encounters in an open stellar cluster  

CERN Document Server

A debris disk is a constituent of any planetary system surrounding a main sequence star. We study whether close stellar encounters can disrupt and strip a debris disk of its planetesimals in the expanding open cluster of its birth. Such stripping would affect the dust production and hence detectability of the disk. We tabulated the fractions of planetesimals stripped off during stellar flybys of miss distances between 100 and 1000 AU and for several mass ratios of the central to passing stars. We then estimated the numbers of close stellar encounters over the lifetime of several expanding open clusters characterized by their initial star densities. We found that a standard disk, with inner and outer radii of 40 and 100 AU, suffers no loss of planetesimals around a star born in a common embedded cluster with star density 20 000 pc^-3. In this environment, a disk loses >97% of its planetesimals around an M-dwarf, >63% around a solar-type star, and >42% ...

2011-01-01

409

Silylation of low-density silica and bridged polysilsesquioxane aerogels  

Energy Technology Data Exchange (ETDEWEB)

Silica and bridged polysilsesquioxane aerogels are low-density materials that are attractive for applications such as thermal insulation, porous separation media or catalyst supports, adsorbents, and cometary dust capture agents. However, aerogels are notoriously weak and brittle making it difficult to handle and machine monoliths into desired forms. This complication prevents the development of many applications that would otherwise benefit from the use of the low-density materials. Here, we will describe our efforts to chemically modify and mechanically enhance silica-based aerogels using chemical vapor techniques without sacrificing their characteristic low densities. Monolithic silica and organic-bridged polysilsesquioxane aerogels were prepared by sol-gel polymerization of the respective methoxysilane monomers followed by supercritical carbon dioxide drying of the gels. Then the gels were reactively modified with silylating agents to demonstrate the viability ...

2004-01-01

410

Review of Central Research Institute of Electric Power Industry. Coal utilization technology harmonious with the environment. Kankyou ni yasashii sekitann riyo gijyutu. Kankyo ni yasashii sekitan riyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Studies are made on coal in terms of its effective utilization, coal cleaning, fluidization and production of new fuel, and issues globally raised. Coal is abundant in reserves and high in supply stability and economic efficiency. However, it is much in CO2 emission per calorific value. To control as much CO2 emission as possible, effective utilization such as increasing of power generation efficiency has been proceeded with. In addition to ultra supercritical pressure and fluidized bed combustion, cited are coal gasification combined cycle power generation and high temperature type fuel cell. Coal has 5-20% ash and impurities like sulfur/nitrogen. Coal should be used clean by pollution abatement measures such as dust collecting, desulfurization and denitrification. Japan is at a world top level of these technologies. Coal is solid, and therefore, is more difficult to handle than liquid fuel. To use it easily, coal is liquefied into slurry such as COM and CWM, and ...

1994-04-25

411

Research and development of new coal based combined cycle power plant concept  

Energy Technology Data Exchange (ETDEWEB)

Out of concern for the global environment, technologies for coal-fired combined cycle power generation are under development throughout the world today, aiming at highly efficient use of coal. Under these circumstances, the authors and others, with the intention of producing a coal-fired combined cycle power generation system with higher plant efficiency, lower construction cost, and higher reliability than conventional systems, proposed a new gasification combined cycle power generation system that differs from the conventional IGCC system. The authors studied system configuration and conducted elementary research necessary for implementing the system. This report deals with the basic concepts of the system and the results of basic studies carried out to realize of the concepts, including a study on alkali metal vapour concentration in relation to heat corrosion; the relation between gas de-dusting temperature and gas alkali metal vapour concentration; and basic ...

1997-12-31

412

Problems of waste disposal in the handling of natural radioactive material not subject to authorisation  

International Nuclear Information System (INIS)

With the exception of some minerals, the specific activity of natural radioactive material is below 370 Bq/g, their handling thus not being subject to authorization or the duty of reporting according to section 4 para. 2 of the Radiological Protection Ordinance. Moreover, there is required no handling license for prospecting, mining and processing of radioactive minerals; they are subject to the procedures for the plans of operation of the mining laws of the Federal States. License-free handling of natural radioactive material may result in the production of radioactive waste, the disposal of which must be authorized according to sect. 47 of the Radiological Protection Ordinance if the specific activity exceeds the free amounts of column 4 in Table IV of Appendix IV by a factor of 10"-"4/g. This inconsistency is discussed by means of the following examples: (1) fly ash and slag from coal power plants, (2) flue dust from sintering plants, (3) red mud from aluminium ...

1980-05-01

413

Paleo-botanical evidence for ecosystem disruption at the Cretaceous-Tertiary boundary from Wood Mountain, Saskatchewan, Canada  

Energy Technology Data Exchange (ETDEWEB)

A continuous, subsurface Cretaceous-Tertiary boundary section, including the boundary clay within an 87 cm thick lignite, has been recovered from a core hole near Wood Mountain, Saskatchewan, Canada. The lignite-encompassed clay layer with geochemical anomaly indicates that peat deposition was continuous across the boundary. Core data indicate that, locally, a pre-boundary, conifer-dominated swamp was abruptly replaced by an angiosperm-dominated, herbaceous wetland. Sudden extermination of the dominant forest elements indicates mass kill at the level of the boundary and supports the theory of extraterrestrial impact accompanied by catastrophic destruction. Devastation of the standing vegetation may have been caused by one or more of the killing agents predicted to have accompanied impact, including freezing temperatures caused by atmospheric dust, acid rain, thermal pulse, and shock waves. There is no evidence supporting wildfires as a killing agent. Vegetational ...

1999-05-01

414

Multi-wavelength observations of the young binary system Haro 6-10: The case of misaligned discs  

CERN Document Server

Context. We present a multi-wavelength, high-resolution observational survey of the young binary system Haro 6-10 (GV Tau, IRAS 04263+2426), which is harbouring one of the few known infrared companions. Aims. The primary goal of this project is to determine the physical and geometrical properties of the circumstellar and circumbinary material in the Haro 6-10 system. Methods. High-resolution optical (HST/WFPC2) and near-infrared (VLT/NACO) images in different bands were analysed to investigate the large-scale structures of the material around the binary.Mid-infrared interferometry (VLTI/MIDI) and spectroscopy (TIMMI2 at the 3.6m ESO telescope) were carried out to determine the structure and optical depth of the circumstellar material around the individual components. Results. The multi-wavelength observations suggest that both components of the binary system Haro 6-10 are embedded in a common envelope. The measured extinction indicates a dust composition of the ...

2011-01-01

415

Mulled coal - a beneficiation coal form for use as a fuel or fuel intermediate. Technical progress report No. 9, April 1, 1992--June 30, 1992  

Science.gov (United States)

Under the auspices of the DOE and private industry, considerable progress has been made in: preparation of coal-water fuels; combustion of low-ash coal-based fuel forms; processes to provide deeply-cleaned coal. Developments in advanced beneficiation of coal to meet stringent requirements for low ash and low sulfur can be anticipated to further complicate the problem areas associated with this product. This is attributable to the beneficiated coal being procured in very fine particles with high surface areas, modified surface characteristics, reduced particle size distribution range, and high inherent moisture. Experience in the storage, handling, and transport of highly beneficiated coal has been limited. This is understandable, as quantities of such product are only now becoming available in meaningful quantities. During this reporting period the authors have: developed a suite of empirical tests covering water retention, rewetting, mull stability, angle of repose, ...

1993-01-01

416

Modeling the Galactic CV Distribution for the ChaMPlane Survey  

CERN Document Server

For purposes of designing targeted cataclysmic variable (CV) detection surveys and interpreting results of other projects with many CV detections such as the ChaMPlane Survey, we have created a model of the CV distribution in the Galaxy. It is modeled as a warped, flared exponential disk with a gaussian vertical distribution. Extinction is based on a detailed Galactic dust and gas model. A luminosity function for CVs is also incorporated, based on a smoothed version of published data. We calculate predicted field detection rates as a function of the limiting magnitude expected for the detecting system (i.e. WIYN/Hydra or NOAO 4m/Mosaic). Monte-Carlo techniques are used to assess statistical fluctuations in these rates. We have created maps of the expected CV distribution for the full non-bulge Galactic plane (20

2007-01-01

417

Microbeam analysis of heavy element phases in polished sections of particulate material -- An improved insight into origin and bioavailability  

Energy Technology Data Exchange (ETDEWEB)

The contamination of environmental materials (soil and dust) by heavy elements is of concern in assessing environmental pollution. Characterization of samples is performed in order to provide information that can be used to assess the potential hazard of the material, to assess remediation strategies, and to determine the source of the heavy element-bearing material. Microbeam analysis using a scanning electron microscope (SEM) or electron microprobe on polished particle mounts allows the size, internal morphology and chemical composition to be determined on a particle-by-particle basis. Computer controlled SEM allows all factors except internal structure to be acquired in an automated fashion. The authors present examples of two studies using microbeam techniques. In the first example, they illustrate how cadmium associated with sphalerite in soils can be quantified at levels down to a few parts per million (ppm) using computer controlled SEM techniques. In the ...

1996-12-31

418

Ly-alpha emitters: blue dwarfs or supermassive ULIRGs? Evidence for a transition with redshift  

CERN Document Server

The traditional view that Ly-alpha emission and dust should be mutually exclusive has been questioned more and more often, notably the observations of Ly-alpha emission from ULIRGs seems to counter this view. In this paper we seek to address the reverse question: How large a fraction of Ly-alpha selected galaxies are ULIRGs? Using two samples of 24/25 Ly-alpha emitting galaxies at z = 0.3/2.3 we perform this test, also including results at z = 3.1, and find that whereas the ULIRG fraction at z = 3.1 is very small, it systematically increases towards lower redshifts. There is a hint that this evolution may be quite sudden and that it happens around a redshift of z ~ 2.5. Measuring the infrared luminosities of the Ly-alpha emitters, we find that they are in the normal to ULIRG range in the lower redshift sample, whereas the higher redshift galaxies all have luminosities in the ULIRG category. The Ly-alpha escape fractions for these infrared bright galaxies are in the ...

2009-01-01

419

Investigation of natural radionuclides in selected NORM-samples  

International Nuclear Information System (INIS)

A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different densities, and the analysis of low-energy ...

2005-09-20

420

Investigating the complex X-ray spectrum of a broad-line 2MASS red quasar: XMM-Newton observation of FTM 0830+3759  

CERN Document Server

We report results from a 50 ks XMM-Newton observation of the dust-reddened broad-line quasar FTM 0830+3759 (z=0.413) selected from the FIRST/2MASS Red Quasar survey. For this AGN, a very short 9 ks Chandra exposure had suggested a feature-rich X-ray spectrum and HST images revealed a very disturbed host galaxy morphology. Contrary to classical, optically-selected quasars, the X-ray properties of red (i.e. with J-Ks> 1.7 and R-Ks> 4) broad line quasars are still quite unexplored, although there is a growing consensus that, due to moderate obscuration, these objects can offer a unique view of spectral components typically swamped by the AGN light in normal, blue quasars. The XMM-Newton observation discussed here has definitely confirmed the complexity of the X-ray spectrum revealing the presence of a cold (or mildly-ionized) absorber with Nh ~10^{22} cm^-2 along the line of sight to the nucleus and a Compton reflection component accompanied by an intense Fe K ...

2010-01-01

421

Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics  

Energy Technology Data Exchange (ETDEWEB)

This paper reports thermal comfort and indoor air quality (IAQ) studies of an under-floor air-conditioning (UFAC) system in a hot and humid climate. Thermal comfort parameters were measured at pre-determined grid points within an imaginary plane to predict the air flow pattern of the supply air jet as well as to determine the occurrence of thermal stratification in the office space. Fanger's thermal comfort index was also computed to detect the occupants' thermal sensation. Besides, the concentration levels of dust and carbon dioxide were recorded with the intention to examine the quality of the indoor air. Statistical methods were applied to derive the relationship between air velocity and the other parameters as mentioned earlier. The main findings from the study revealed reasonable level of acceptability of IAQ associated with the UFAC system. However, occupants are likely to experience localised thermal discomfort near the supply diffusers due ...

2002-07-01

422

In-depth survey report of Early and Daniel Co. , Inc. , Louisville, Kentucky  

Science.gov (United States)

An in-depth industrial hygiene survey was conducted to evaluate worker exposures to phosphine during fumigation of grain at the Early and Daniel Co. grain elevator in Louisville, Kentucky. Stored grain was fumigated using aluminum phosphide. Aluminum-phosphide pellets were also added directly to the grain by the blender as it was poured into the storage containers. Local exhaust ventilation was used at points in the grain-moving system where grain dust was generated. Air samples were taken during full-shift periods at the breathing zone of the weighmaster, two bin floormen, and the blender. Area monitoring samples were also taken. If the operators spend considerable time in the vicinity of a bin which is being filled with grain, there is a likelihood of far greater exposure levels being noted. According to the author, further studies of the use of phosphide products at other elevators should be conducted to determine the effect of environmental and process ...

1986-09-01

423

In-depth industrial-hygiene survey report of the Bunge Corporation, Kansas City, Kansas  

Science.gov (United States)

Potential exposure of workers to phosphide was examined during an in-depth industrial hygiene survey at the Bunge Corporation, in Kansas City, Kansas, where the gas was used as a grain fumigant. During the study, 14 men were employed at the facility. Tablets of aluminum phosphide were added to the grain mass for fumigation. General dilution ventilation resulted from outside air entering the work areas through ventilation louvers; there was also a local-exhaust ventilation system. Air samples revealed that, when the fumigant dispensers were being filled, workers in the area had significant exposure. At the time of the survey the relative humidity in the facility was high, permitting the reaction to phosphide to occur more readily. The levels of phosphide and respirable dust were reasonably low in the elevators, suggesting that the ventilation system was adequate. The author recommends that workers filling the dispenser with the aluminum phosphide be required to wear ...

1986-09-01

424

IC 4767 (the X-galaxy) - the missing link for understanding galaxies with peanut-shaped bulges?  

International Nuclear Information System (INIS)

Photometric and kinematic observations of the peculiar S0 galaxy IC 4767, the X-galaxy, are presented. At various intensities the bulge of this galaxy looks like a normal spheroidal system with elliptical isophotes, a well-defined rectangle, and a peanut-shaped or X-shaped structure with components aligned at oblique angles to the major axis. The observations reveal a rapidly rotating inner disk of gas and dust which is nearly aligned with the major axis. The presence of gaseous emission alone suggests an accretion event. The stars in the outer regions of the X-component are rotating nearly as rapidly as the gas in the main disk, indicating that they are in relatively circular orbits. The five most prominent peanut-shaped bulges all have several nearby companions, evidence that the peanut deformity is due to interaction between galaxies. An analogy with the formation mechanism proposed for polar-ring galaxies suggests how an X-shaped component could develop from ...

1988-01-01

425

Homoclinic chaos in the dynamics of a general Bianchi type-IX model  

International Nuclear Information System (INIS)

The dynamics of a general Bianchi type-IX model with three scale factors is examined. The matter content of the model is assumed to be comoving dust plus a positive cosmological constant. The model presents a critical point of saddle-center-center type in the finite region of phase space. This critical point engenders in the phase space dynamics the topology of stable and unstable four dimensional tubes RxS"3, where R is a saddle direction and S"3 is the manifold of unstable periodic orbits in the center-center sector. A general characteristic of the dynamical flow is an oscillatory mode about orbits of an invariant plane of the dynamics which contains the critical point and a Friedmann-Robertson-Walker (FRW) singularity. We show that a pair of tubes (one stable, one unstable) emerging from the neighborhood of the critical point towards the FRW singularity have homoclinic transversal crossings. The homoclinic intersection manifold has topology RxS"2 and is ...

2002-04-15

426

Health-hazard evaluation report HETA 85-354-1872, Asarco, Denver, Colorado  

Science.gov (United States)

An evaluation was made of possible hazardous working conditions at the ASARCO Globe facility, Denver, Colorado. The facility was involved in the recovery of cadmium from baghouse dust, a waste byproduct of nonferrous smelters. A medical study of kidney function was conducted in 45 current or former cadmium production workers; results were compared to those for 35 hospital workers. Kidney abnormalities were more common and more severe in the cadmium workers than in the hospital workers. Abnormalities of proximal tubular function included reduced reabsorption of beta-2-microglobulin, retinol binding protein, calcium and phosphate. Glomerular dysfunction was evidenced as elevated serum creatinine. As length of exposure to cadmium increased, changes became more apparent in workers. No reversal of the conditions was noted in workers who had ceased to be exposed to cadmium some time before the study. The authors conclude that occupational overexposure to cadmium caused ...

1988-02-01

427

Formation of methyl formate and other organic species in the warm-up phase of hot molecular cores  

CERN Document Server

Aims: The production of saturated organic molecules in hot cores and corinos is not well understood. The standard approach is to assume that, as temperatures heat up during star formation, methanol and other species evaporate from grain surfaces and undergo a warm gas-phase chemistry at 100 K or greater to produce species such as methyl formate, dimethyl ether, and others. But a series of laboratory results shows that protonated ions, typical precursors to final products in ion-molecule schemes, tend to fragment upon dissociative recombination with electrons rather than just ejecting a hydrogen atom. Moreover, the specific proposed reaction to produce protonated methyl formate is now known not to occur at all. Methods: We utilize a gas-grain chemical network to probe the chemistry of the relatively ignored stage of hot core evolution during which the protostar switches on and the temperature of the surrounding gas and dust rises from 10 K to over 100 K. During this ...

2006-01-01

428

Discovery of a strong Baldwin effect in mid-infrared AGN lines  

CERN Document Server

We present the discovery of a Baldwin effect in 8 nearby Seyfert galaxies for the three most prominent mid-infrared forbidden emission lines observable from the ground that are commonly found in AGN, [ArIII](8.99 micron), [SIV](10.51 micron), and [NeII](12.81 micron). The observations were carried out using the VLT/VISIR imager and spectroraph at the ESO/Paranal observatory. The bulk of the observed line emission comes from the inner <0.4 arcsec which corresponds to spatial scales <100 pc in our object sample. The correlation index is approximately -0.6 without significant difference among the lines. This is the strongest anti-correlation between line equivalent width and continuum luminosity found so far. In the case of Circinus, we show that despite the use of mid-infrared lines, obscuration by either the host galaxy or the circumnuclear dust torus might affect the equivalent widths. Given the small observed spatial scales from which most of the line ...

2008-01-01

429

Decontamination factor of air filter against /sup 198/Au aerosol particles  

Energy Technology Data Exchange (ETDEWEB)

DF (decontamination factor) of two types of air filter was investigated against /sup 198/Au aerosol particles with AMAD (activity median aerodynamic diameter) = 1.2 ..mu..m and sigmag (geometric standard deviation) = 2.0. One of the filters, SO filter, is HEPA (high efficiency particulate air) filter media with 46 mmphi, and the other is HE-40T (cellulose-glass fiber filter for dust sampling) filter media with 40 mmphi. DF of the SO filter was found to be over 5 x 10/sup 4/ at air flow rate of 1 lmin. And DF of HE-40 T filter was determined to be 94+-4 at the same airflow rate. In the multistage HE-40 T filter system, DF decreased at each succeeding stage. It was confirmed by numerical simulation that the decrease of DF was not inconsistent with the decrease of collection performance in each successive filter. It was also confirmed that DF could be predicted by the numerical simulaiton, if particle penetration function of filter and size distribution function of ...

1987-12-01

430

Decontamination factor of air filter against "1"9"8Au aerosol particles  

International Nuclear Information System (INIS)

DF (decontamination factor) of two types of air filter was investigated against "1"9"8Au aerosol particles with AMAD (activity median aerodynamic diameter) = 1.2 #mu#m and #sigma#g (geometric standard deviation) = 2.0. One of the filters, SO filter, is HEPA (high efficiency particulate air) filter media with 46 mm#phi#, and the other is HE-40T (cellulose-glass fiber filter for dust sampling) filter media with 40 mm#phi#. DF of the SO filter was found to be over 5 x 10"4 at air flow rate of 1 l/min. And DF of HE-40 T filter was determined to be 94#+-#4 at the same airflow rate. In the multistage HE-40 T filter system, DF decreased at each succeeding stage. It was confirmed by numerical simulation that the decrease of DF was not inconsistent with the decrease of collection performance in each successive filter. It was also confirmed that DF could be predicted by the numerical simulaiton, if particle penetration function of filter and size distribution function of ...

431

Collection and analysis of particulate from the DIII-D Tokamak  

International Nuclear Information System (INIS)

Particulate (i.e. tokamak dust) has been collected from the DIII-D tokamak located at General Atomics in San Diego, CA, USA. Two methods were used to collect particulate with the goal of preserving the particle size distribution and physical characteristics of the particulate. Vacuum collection on substrates and adhesion removal with metallurgical replicating tape were chosen as non-intrusive sampling methods. Sampling was completed in four toroidal locations of the machine; the 0-90 area, the 90-180 area, the 180-270 area, and the 270-360 area. The 0 direction designates the north side of the DIII-D machine. Four tiles in each area were sampled; the first vertical tile above the floor on the centerpost, a floor tile next to the center post, a tile on the isolated ring, and the first tile up from the isolated ring on the divertor. In addition, samples were collected from underneath the floor tiles at the 275 and the 75 locations. The count median diameter of the ...

1998-09-01

432

Coal power stations in 2000/2015; Kohlenkraftwerke im Jahr 2000/2015  

Energy Technology Data Exchange (ETDEWEB)

Developments in the past 10 -15 years in the fiels of `steel`, `boilers`, `steam turbines` and `environmental protection` show that the advanced coal dust furnace technology is another option of clean coal technology. The contribution discusses some of the current problems facing the main partners of the coal sector, e.g. coal producers, public utilities and suppliers of steel, boilers and turbines. (orig./GL) [Deutsch] Die Entwicklung der vergangenen 10-15 Jahre in den Bereichen `Stahl`, `Kessel`, `Dampfturbinen` und `umweltschutztechnische Anlagen` verdeutlicht, dass die fortgeschrittene Kohlestaubfeuerungstechnologie ebenfalls eine Option der `Clean Coal Technologies` ist. Im Rahmen dieses kurzen Aufsatzes wird nun versucht, einige zeitgemaesse Problemkreise der Hauptakteure des Strommarktes, wie z.B. des Kohlefoerderers, der Stromproduzenten und der Stahl-, Kessel- sowie Turbinenhersteller anzudeuten. (orig./GL)

1996-12-31

433

COLLISIONAL AND LUMINOSITY EVOLUTION OF A DEBRIS DISK: THE CASE OF HD 12039  

International Nuclear Information System (INIS)

Extrasolar debris disks that are bright enough to be observed are dense enough to be collision-dominated; i.e., the small grains that produce their infrared excess have collisional lifetimes shorter than their Poynting-Robertson decay times. This paper describes a numerical code for the modeling of such disks, including accretion and gravitational stirring as well as disruptive collisions. A constraint relating the mass of a debris disk and the sizes of the largest embedded bodies to its luminosity is demonstrated. The collisional code is applied to the debris disk around HD 12039, which has been intensively observed by the Spitzer Space Telescope. The evolution in time of the disk's luminosity is computed for a range of initial disk masses and planetesimal sizes. The luminosity at a given age depends on both the initial disk mass and the initial size of the planetesimals. Luminosity decays more rapidly for massive disks due to the combination of collisional depletion of small bodies ...

2010-10-20

434

Application of fluidized-bed combustion plants in the field of energy technology; Einsatz von Wirbelschichtfeuerungsanlagen in der Energietechnik  

Energy Technology Data Exchange (ETDEWEB)

In the future fossil fuelled power plants are realised/laid down as combined cycle power plants with high current generation efficiencies. The method of pressure fluidized-bed combustion with downstream hot gas cleaning is going to compete with methods combined with a pressure coal gasification or a pressure dust combustion. The advantages of the pressure fluidized bed combustion are the simpler method set-up and consequently lower investment costs. (orig./CD) [Deutsch] Kohlegefeuerte Kraftwerke werden zukuenftig als kombinierte Gas/Dampfturbinen-Kraftwerke mit hohen Stromerzeugungswirkungsgraden ausgefuehrt werden. Das Verfahren der Druckwirbelschichtverbrennung mit nachgeschalteter Heissgasreinigung und Rauchgasturbine wird dabei mit Verfahren mit einer vorgeschalteten Kohledruckvergasung oder mit einer Druckstaubfeuerung konkurrieren. Die Vorteile der Druckwirbelschichtverbrennung liegen dabei auf dem insgesamt einfacheren Verfahrensaufbau und damit wohl auch ...

1993-12-31

435

ARIES-AT safety design and analysis  

Energy Technology Data Exchange (ETDEWEB)

ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under average weather conditions. We also provide ...

2006-01-15

436

ARIES-AT safety design and analysis  

International Nuclear Information System (INIS)

ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under average weather conditions. We also provide ...

2006-01-01

437

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak luminosity of CXOGC J174540.0-290031 was >2e36 erg/s. We suggest that the relatively small observed ...

2005-01-01

438

Energy from wood - part 3: automatic wood furnaces; Holzenergie, Teil 3: automatische Holzfeuerungen - Energie du bois, Partie 3: installations automatiques de chauffage au bois  

Energy Technology Data Exchange (ETDEWEB)

The paper gives an overview on the technologies and applications of automatic wood furnaces. The combustion systems are defined by the flow condition: With increasing gas velocity, fixed bed, stationary fluidized bed (SFB), circulating fluidized bed (CFB), and entrained flow reactors are distinguished. The furnace design and typical applications are described. Further, a comparison is presented which gives data of the typical size range and fuel types for the different combustion systems. The most common fixed bed reactors are under-stoker and grate furnaces. While under-stoker furnaces are applied in the size range from 20 kW to 2.5 MW, grate furnaces cover the size range from a few 100 kW up to more than 50 MW. Under-stoker furnaces are well suited for wood fuel with low ash content, moderate water content and limited fuel size. Grate furnaces are also suited for fuel with high ash and water content and large fuel sizes. Hence grate furnaces are nowadays most common. Due to the ...

2001-07-01

439

The cascad spent fuel dry storage facility  

International Nuclear Information System (INIS)

France has a wide variety of experimental spent fuels different from LWR spent fuel discharged from commercial reactors. Reprocessing such fuels would thus require the development and construction of special facilities. The French Atomic Energy Commission (CEA) has consequently opted for long-term interim storage of these spent fuels over a period of 50 years. Comparative studies of different storage concepts have been conducted on the basis of safety (mainly containment barriers and cooling), economic, modular design and operating flexibility criteria. These studies have shown that dry storage in a concrete vault cooled by natural convection is the best solution. A research and development program including theoretical investigations and mock-up tests confirmed the feasibility of cooling by natural convection and the validity of design rules applied for fuel storage. A facility called CASCAD was built at the CEA's ...

1991-04-14

440

Solar expriment begins at Atlanta school. [George A. Towns Elementary School  

Science.gov (United States)

The largest solar heating and cooling system undertaken to date is now operating at the George A. Towns Elementary School in Atlanta, Georgia. It is expected to provide more than 60 percent of the building's heating and cooling requirements, using commercially available components and techniques. The Towns project is a United States Energy Research and Development Administration-sponsored experiment. The principal components of the solar heating and cooling system designed for the school--the solar collector array, the existing gas-fired boiler, the absorption chiller, and hot and cold water underground tanks to provide thermal storage--are described. To derive maximum benefit from the experiment, the system is fully instrumented for accurate measurement of performance. Environmental data, including insolation and ambient temperture, humidity, and wind conditions will be recorded. The inlet temperatures, outlet ...

1976-03-01

441

Simulations of a Gas-Filled Helical Muon Beam Cooling Channel  

Energy Technology Data Exchange (ETDEWEB)

A helical cooling channel (HCC) has been proposed to quickly reduce the six-dimensional phase space of muon beams for muon colliders, neutrino factories, and intense muon sources. The HCC is composed of a series of RF cavities filled with dense hydrogen gas that acts as the energy absorber for ionization cooling and suppresses RF breakdown in the cavities. Magnetic solenoidal, helical dipole, and helical quadrupole coils outside of the RF cavities provide the focusing and dispersion needed for the emittance exchange for the beam as it follows a helical equilibrium orbit down the HCC. In the work presented here, two Monte Carlo programs have been developed to simulate a HCC to compare with the analytic predictions and to begin the process of optimizing practical designs that could be built in the near future. We discuss the programs, the comparisons with the analytical theory, and the prospects for a HCC design with the capability to reduce the ...

2005-05-16

442

Simulation of electromechanical and thermomechanical loads on first wall mock-ups  

International Nuclear Information System (INIS)

In order to study the boundary conditions for the occurrence of ratcheting, a testing rig was erected. In this rig, small-scale mock-ups of the first wall were tested under mechanical conditions similar to those expected during disruptions. These mock-ups were made of stainless steel AISI 316. They were heated on the surface and water cooled from inside. Disruption forces were simulated by a high-speed hydraulic bending system by impact loads. The mock-ups were heated by a high-frequency generator and cooled by water through two cooling channels.In addition to the experimental work, simplified analytical analysis and numerical calculations were carried out using the finite element program ABAQUS. In these calculations, the temperature and stress fields in the mock-ups were investigated and the influence of the different constitutive equations was studied.The experimental results confirm the ratcheting behaviour predicted by ...

443

Reflood experiments with simultaneous upper and lower plenum injection in the REWET-II rod bundle facility  

International Nuclear Information System (INIS)

A series of 27 reflood experiments has been carried out in a full-length electrically heated rod bundle facility. The primary objective of these tests was to study the effects of a simultaneous upper plenum and downcomer coolant injection and to provide data for the verification of computer codes. The experimental results indicate that an upper plenum injection alone cools the test rods slowly, a simultaneous coolant injection to the downcomer improves cooling significantly, and a downcomer injection alone cools the test rod bundle best if the total value of the coolant flow rate is the same in these three different cases. If the coolant injected to the upper plenum increases the total flow rate, the quench time of the test rods decreases at all elevations. Quenching time and clad temperature histories calculated with the computer codes NORCOOL-I and FLOOD4 are in a reasonable quantitative agreement with experiments in the ...

1983-02-01

444

Precooling techniques and applications for horticultural products - a review  

Energy Technology Data Exchange (ETDEWEB)

One of the most important factors affecting the postharvest life and quality of horticultural crops is temperature. Quality loss after harvest occurs as a result of physiological and biological processes, the rates of which are influenced primarily by product temperature. As the maintenance of market quality is of vital importance to the success of the horticultural industry, it is necessary not only to cool the product but to cool it as quickly as possible after harvest. The process of precooling is the removal of field heat which arrest the deteriorative and senescence processes so as to maintain a high level of quality that ensures customer satisfaction. This paper provides a critical review to portray precooling as an intricate part of temperature management and to highlight the importance of its utilisation for extending the shelf life and maintaining the quality of horticultural products with emphasis on cut flowers. Various different ...

2001-07-01

445

Phytoplankton primary production in a eutrophic cooling water pond  

Energy Technology Data Exchange (ETDEWEB)

The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for photosynthesis in the spring. The phytoplankton biomass starts to increase early in the spring when the ...

1984-01-01

446

Neutrino-Cooled Accretion Disks around Spinning Black Hole  

CERN Document Server

We calculate the structure of accretion disks around Kerr black holes for accretion rates 0.001 - 10 M_sun/s. Such disks are plausible candidates for the central engine of gamma-ray bursts. Our disk model is fully relativistic and treats accurately microphysics of the accreting matter: neutrino emissivity, opacity, electron degeneracy, and nuclear composition. The neutrino-cooled disk forms above a critical accretion rate that depends on the black hole spin. The disk has the ``ignition'' radius r_ign where neutrino flux rises dramatically, cooling becomes efficient, and the proton-to-nucleon ratio Y_e drops. Other characteristic radii are r_alpha where most of alpha-particles are disintegrated, r_nu where the disk becomes neutrino-opaque, and r_trap where neutrinos get trapped and advected into the black hole. We find r_alpha, r_ign, r_nu, r_trap and show their dependence on the accretion rate. We discuss the qualitative picture of accretion ...

2006-01-01

447

Multipass laser mass spectrometer with extreme jet-cooled pulsed gas  

International Nuclear Information System (INIS)

We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution ...

2006-09-01

448

Multi-Objective Optimization of Cooling Channel Roughened by Dimples  

Science.gov (United States)

Shape optimization of heat transfer augmentation device employed in turbine blade internal cooling passage has been performed numerically using single as well as multi-objective optimization procedures. Polynomial response surface approximation method and multi-objective genetic algorithm are used for single and multi-objective optimizations, respectively. Problem to enhance heat transfer rate considering staggered dimples on single surface of cooling passage has been formulated, and Reynolds-averaged Navier-Stokes equations are solved to analyze the flow field and the heat transfer. Three design variables defining channel and dimple dimensions, and two objective functions related to Nusselt number and friction drag are employed. Latin hypercube sampling is used to generate sampling points in design space, and the evaluated objectives are used to generate a set of optimal designs. Optimal shapes show higher heat transfer rates in the case of ...

2008-01-01

449

Method for controlling a coolant liquid surface of cooling system instruments in an atomic power plant  

International Nuclear Information System (INIS)

Object: To prevent coolant inventory within a cooling system loop in an atomic power plant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic power plant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which is provided with an overflow pipe in its ...

450

Management of pitfalls for the successful clinical use of hypothermia treatment.  

Science.gov (United States)

Therapeutic hypothermia is a promising method for controlling intracranial pressure (ICP) in severely brain-injured patients. However, clinical data regarding the effect of brain hypothermia on overall outcome of these patients is limited. This may be because there are specific pitfalls associated with the clinical management of induced hypothermia in patients with severe traumatic brain injury (TBI). These pitfalls may be avoided by preventing specific risk factors when cooling is induced and with rewarming. However, these risk factors have not been well systematically discussed in the literature. In this paper, three categories of clinical issues regarding the management of brain hypothermia are discussed: (1) stress-induced secondary brain injury mechanisms; (2) technical aspects of intensive care unit (ICU) cooling management; and (3) rewarming rates and methods. For patients with a Glasgow Coma Scale (GCS) score of less than 8, management ...

2009-03-01

451

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water ...

2006-03-01

452

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water ...

2006-03-01

453

Improvement of local air coolers model in ISAAC  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to assess a new local air coolers model in ISAAC 2.0, as ISAAC 1.0 could model local air coolers only at two locations. In the new model, local air coolers up to twelve locations could be handled. Large LOCA and loss of feed water sequences were selected for the model comparison. Two cases were analyzed with ISAAC 2.0: one with 6 local air coolers in one of the fueling machine room and in the steam generator room, respectively, and the other with 3 local air coolers at both fueling machine room and 6 local air coolers in the steam generator room. The study assumes that the safety systems such as emergency core cooling system, shield cooling system and moderator cooling system are unavailable. According to the ISAAC 2.0 results, the new local air coolers model showed almost no difference between two cases. Also it was found that as the location of LACs increased, the new model worked properly and ...

2004-02-01

454

Free and forced convective cooling of pipe-type electric cables. Volume 2: electrohycrodynamic pumping. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...

1981-05-01

455

Fluid dynamics analysis of a Ranque-Hilsch vortex tube  

International Nuclear Information System (INIS)

Fluid dynamic analysis of a commercial, counter-flow Ranque-Hilsch Vortex Tube (Rh vt), Ex air 25 s cfm, has been performed in this work both experimentally and numerically; in particular Rh vt cooling power and temperature separation performances have been tested in both direct cooling employment (jet impingement) and indirect cooling employment (supplying cold plates). Experimental techniques, used in this work, revealed several difficulties to produce detailed information about velocity and temperature fields inside the tube and at both the exits. Hence numerical simulation of the flow inside the tube has been conducted using the commercial Cfd code Fluent 6.3.26. Compressible, turbulent, high swirling flow inside Rh vt has been simulated by using both Rans and Les approaches. In particular several turbulence closures have been used in the Rans simulations and results have been compared with Les ones. Large Eddy ...

2008-05-01

456

Experiments on liquid immersion natural convection cooling of leadless chip carriers mounted on ceramic substrate  

Science.gov (United States)

An experimental investigation of natural convection heat transfer from a commercially available semiconductor device package is presented. The package was centrally mounted on a ceramic substrate. The package-substrate assembly formed one surface of a dielectric-filled cubical enclosure of aspect ratio one. The top surface of the enclosure was maintained at prescribed temperature. Surface temperature measurements were made at various locations on the substrate, the package lid, as well as the chip center. These measurements are reported for three dielectric fluids and three enclosures top surface temperatures, both with the substrate oriented horizontally as well as vertically. The results indicate that the maximum input power without exceeding a chip junction temperature of 80 C is 2.58 watts with FC-75 as the cooling fluid and the upper boundary maintained at 15 C. This is significantly larger than the maximum of 1.21 watts allowable with the natural convection ...

1989-09-01

457

Experimental simulation of heat transfer augmentation by break-jets in passive containment cooling system  

International Nuclear Information System (INIS)

The studies of forced jet augmentation of natural convection heat transfer are introduced. It investigates experimentally mixed convection and heat transfer augmentation by forced jets in a large rectangular enclosure with a vertical cooling surface. The experiment is designed to measure the key parameters governing the heat transfer augmentation by a forced jet, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio, on conditions simulating those of actual passive containment cooling systems and scales approaching those of actual containment buildings or compartments. The tests that cover a variety of injection modes will contribute to reveal the nature of mixing and stratification phenomena under accident conditions to a new generation of inherently safe reactors. With similarity considerations on governing equations, the heat transfer of ...

2010-02-01

458

Chalk Point cooling tower project native vegetation study. Final report 1979  

Science.gov (United States)

The Potomac Electric Power Company generating station at Chalk Point, MD, utilizes brackish water in its natural draft cooling tower and, consequently, releases saline aerosol into the atmosphere. A research and monitoring project was established in 1974 to evaluate the effects of this drift on native perennial vegetation. Leaf samples have been collected form dogwood, Cornys florida, Virginia pine, Pinus virginiana, black locust, Robinia pseudoacacia, and sassafras, Sassafras albidum, located at 12 different sites in the vicinity of the power plant. Sampling was begun prior to the operation of the cooling tower, 1974, and continued through 1978. Complete results from monthly monitoring of foliar chloride in the four native tree species is documented for May through September 1978. Results from salt spray experiments indicate chloride and sodium concentrations in the wood of dogwood trees increases with increased spraying levels.

1979-06-01

459

Three-dimensional laminar and turbulent natural convection cooling of heated blocks  

International Nuclear Information System (INIS)

Results of three-dimensional laminar and standard K-#epsilon# turbulent numerical simulations of natural convection cooling of ten cubic aluminum blocks mounted on an insulated plate, facing a shrouding wall, are presented. This geometry is chosen so that comparison with experimental results is possible. The considered problem is of great practical importance because it simulates the case of heated electronic chips, mounted on printed board assemblies, which are frequently encountered in electronic industry applications. The problem is mathematically modeled by the three-dimensional conservation differential equations of mass, momentum, energy and turbulent kinetic energy and dissipation (for the turbulent flow model). IN this paper, these equations are numerically solved by a finite volume method and the laminar and turbulent results are compared to the experimental results obtained with similar parameters.

1990-06-18

460

Thermohydraulic study of a MTR fuel element aimed at the construction of an irradiation facility; Estudo termohidraulico de um elemento combustivel tipo MTR visando a construcao de um dispositivo de irradiacao  

Energy Technology Data Exchange (ETDEWEB)

A thermohydraulic study of MTR fuel element is presented as a basic requirement for the development of an irradiation facility for testing fuel elements. A computer code named 'Thermo' has been developed for this purpose, which can stimulate different working conditions, such as, cooling, power elements and neutron flux, performing all pertinent thermohydraulic calculations. Thermocouples were used to measure the temperature gradients of the cooling fluid throughout the IEAR-1 reactor core. All experimental data are in good agreement with the theoretical model applied in this work. Finally, a draft of the proposed facility and its safety system is presented. (author)

1980-07-01

461

Thermoelectrically cooled water trap  

Energy Technology Data Exchange (ETDEWEB)

A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.

2006-02-21

462

Thermal impact analysis of discharge of circulating cooling water at Daya Bay Nuclear Power Station (GNPS) and Ling'ao Nuclear Power Station (LNPS)  

International Nuclear Information System (INIS)

The circulating cooling water flowrate of GNPS and LNPS is totally about 190 m"3/s. Both stations are located on the western coast of semi-closed Daya Bay. A lot of studies concerning thermal impact of GNPS and LNPS have been carried out since 1987, including mathematical model, physical model, on-site survey and satellite remote sensing, etc. This paper describes the hydrological features of Daya Bay and discharge characteristics of circulating water of GNPS and LNPS, estimates the actual thermal impact of GNPS and LNPS, and indicates that it is advantageous for the dilution of circulating water while the two discharge channels of GNPS and LNPS are combined together towards east

2004-05-01

463

The development of open-pore multi-layer systems for steam turbines operating with 700 C technology; Die Entwicklung offenporoeser Mehrschichtsysteme fuer Dampfturbinen der 700 C-Technologie  

Energy Technology Data Exchange (ETDEWEB)

In the context of the special research area 561 (Thermally highly loaded, open-porous and cooled multi-layer systems for combined-cycle power stations), the actual technical and scientific realizations are to be extended and new scientific bases are to be created in order to realize total efficiencies of 65 %. In addition, innovative material solutions and new concepts must be compiled for the cooling and drainage. Under this aspect, the author of the contribution under consideration reports on the development of open-porous multi-layer systems for steam turbines of the 700 C technology. It results an efficiency potential of 12 % and a potential of 15 % with the reduction of CO{sub 2} in relation to the actual state of the art. Thereby, the potential of future combined-cycle power stations is not yet exhausted.

2008-07-01

464

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979  

International Nuclear Information System (INIS)

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).

1994-10-18

465

Sodium monocarboxylates as inhibitors of AZ31 alloy corrosion in a synthetic cooling water  

Energy Technology Data Exchange (ETDEWEB)

This research investigated the inhibiting effects that sodium salts of linear monocarboxylic acids displayed towards the corrosion process of AZ31 Mg alloy in ASTM D 1387 saline solution (a synthetic industrial cooling water). The length of the aliphatic chain of the acids ranged between 7 and 15 carbon atoms. The inhibiting action of these salts can be related to the precipitation of an insoluble magnesium salt, which mainly affected the anodic reaction. The aliphatic chain length controlled the anion solubility and the reaction rate of magnesium carboxylate formation. For all the salts, an optimum concentration was experienced: 10{sup -2} M for sodium decanoate (caprate), 10{sup -3} M for sodium dodecanoate (laurate), 10{sup -4} M for sodium tetradecanoate (myristate); when this concentration was exceeded, a diminution (even a disappearance) in the inhibiting action was found. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

2009-03-15

466

Science at the Theater: Hot Technology, Cool Science  

ScienceCinema

...global warming um ? know he's been right into our our ...who was a little bit about global warming and cooling ...global warming ...america uh we can help ? global warming and reduce the demand for electricity and and ...now means that those who immediately combat global warming ? ...global warming ...global warming ...global warming by ...we ? in terms of the contribution to global warming is a small i mean anything else ...global warming and ...among scientists are speaking out about global warming the only thing they really talk about a year to ...the other factors that affect global warming and i i just feel that ...problem of global warming would have to ...global warming ...global warming ...

467

Production of radioisotopes in the ORNL 86-inch cyclotron  

Energy Technology Data Exchange (ETDEWEB)

The radioisotope production facilities and programs of the 86-Inch Cyclotron are reviewed in this presentation. The 86-Inch Cyclotron is designed to accelerate protons to a maximum energy of 22 MeV for internal targets. These protons are used to bombard metals that are electroplated, potted or soldered to water-cooled plates. Additionally, metals and inorganic compounds are bombarded in water-cooled tube targets. High radioisotope production rates are obtained by beam currents as large as 3 mA. Production rates for /sup 11/C, /sup 57/Co, /sup 67/Ga, /sup 68/Ge, /sup 109/Cd, and other isotopes are presented. The production of /sup 11/C for the carboxyl labeling of amino acids in cooperation with Oak Ridge Associated Universities is discussed. The 86-Inch Cyclotron is used for those programs requiring a larger beam current than is available from commercial cyclotrons.

1981-04-01

468

Presence of pathogenic microorganisms in power-plant cooling waters. Report for October 1, 1979-September 30, 1981  

Energy Technology Data Exchange (ETDEWEB)

Cooling waters from eleven geographically disparate power plants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.

1982-10-01

469

Prediction of thermal conductivity of ethylene glycol-water solutions by using artificial neural networks  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study is to develop an artificial neural network (ANN) model to predict the thermal conductivity of ethylene glycol-water solutions based on experimentally measured variables. The thermal conductivity of solutions at different concentrations and various temperatures was measured using the cylindrical cell method that physical properties of the solution are being determined fills the annular space between two concentric cylinders. During the experiment, heat flows in the radial direction outwards through the test liquid filled in the annual gap to cooling water. In the steady state, conduction inside the cell was described by the Fourier equation in cylindrical coordinates, with boundary conditions corresponding to heat transfer between the solution and cooling water. ...

2009-01-01

470

Neutron physical investigations on the shutdown effect of small boronated absorbing spheres for pebble-bed high-temperature gas-cooled reactors  

Energy Technology Data Exchange (ETDEWEB)

An emergency shutdown system for high-temperature gas-cooled pebble-bed reactors is proposed in addition to the common absorber rod shutdown system. This system is based on the strongly absorbing effect of small boronated graphite spheres (called KLAK), which trickle in case of emergency by gravity from the top reflector into the reactor core. The inner reflector of the Siemens-Argonaut reactor was substituted by an assembly of spherical Arbeitsgemeinschaft Versuchsreaktor fuel elements, and the shutdown effect was examined by installing well-defined KLAK nests inside this assembly. The purpose was to develop and prove a calculational procedure for determining criticality values for assemblies of large fuel spheres and small absorbing spheres.

1987-09-01

471

Natural convection cooling of liquid metal systems  

International Nuclear Information System (INIS)

The recognition that natural convection offers the prospect of an important inherent safety feature for liquid metal cooled reactor systems has provided the impetus for a world-wide research effort over the past decade. Whilst this research has been based on experiment, both plant experiments and out-of-pile experiments, the enormous advances in the development of computing power in recent years have enabled complementary programmes of mathematical modelling through numerical simulation of the transport equations in three spatial dimensions. These not only offer considerable promise for the designer in projecting the behaviour from experiments and prototype plant to full scale plant, they have also proved to be of considerable value in helping us to interpret and understand the results of the experiments themselves. This paper attempts to review the progress made with the emphasis on decay heat removal by natural convection in the pool-type system. (author).

472

Mold heating and cooling microprocessor conversion. Final report  

Energy Technology Data Exchange (ETDEWEB)

Conversion of the microprocessors and software for the Mold Heating and Cooling (MHAC) pump package control systems was initiated to allow required system enhancements and provide data communications capabilities with the Plastics Information and Control System (PICS). The existing microprocessor-based control systems for the pump packages use an Intel 8088-based microprocessor board with a maximum of 64 Kbytes of program memory. The requirements for the system conversion were developed, and hardware has been selected to allow maximum reuse of existing hardware and software while providing the required additional capabilities and capacity. The new hardware will incorporate an Intel 80286-based microprocessor board with an 80287 math coprocessor, the system includes additional memory, I/O, and RS232 communication ports.

1995-07-01

473

Modeling, numerical simulation and experimental verification of the unsteady cooling of a solid body in quiescent ambient air  

Energy Technology Data Exchange (ETDEWEB)

The scope of the present article is two-fold. Firstly, to conduct an experiment to provide the temperature-time history of the cooling of a hot ball bearing in quiescent ambient air. Secondly, to predict the temporal variation of the bearing under the hypothesis of natural convection, radiation or natural convection coexists with radiation for a non-vanishing total hemispherical emissivity of the surface of the bearing. Numerical solutions of the three governing nonlinear lumped heat equations were carried out with a Runge-Kutta-Fehlberg (RKF45) algorithm accounting for automatic step size control. The experimental data was obtained with chrome steel ball bearings of diameter 0.953 cm (7/16 in) heated in an electric oven to a pre-set temperature. The heated bearing was exposed later to ambient air at atmospheric temperature and pressure. (orig.)

2004-07-01

474

Method of feeding a coolant into a reactor  

International Nuclear Information System (INIS)

Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).

475

Method for determining hydrogen mobility as a function of temperature in superconducting niobium cavities  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.

2008-03-11

476

Magnetic refrigeration: the promise and the problems  

Energy Technology Data Exchange (ETDEWEB)

Magnetic refrigeration uses the temperature- and field-dependence of the entropy of some magnetic materials to accomplish cooling. Because of the intrinsically high efficiency of the magnetization and demagnetization process and because of the potential for excellent heat transfer between solids and fluids, magnetic refrigerators promise to have higher efficiency than existing gas-cycle refrigerators. Many ground-based and space-based applications could benefit significantly from the cost savings implied by higher efficiency. Other attributes of these devices are high reliability and low volume and mass per unit cooling power. The development of these refrigerators is underway at several places around the world, including the Los Alamos National Laboratory. The progress to date has been encouraging but some problems have been clearly identified. The arguments for high efficiency and the problems that will need to be solved to achieve this goal ...

1984-01-01

477

Liquid crystal films on curved surfaces: An entropic sampling study  

CERN Document Server

The confining effect of a spherical substrate inducing anchoring (normal to the surface) of rod-like liquid crystal molecules contained in a thin film spread over it has been investigated with regard to possible changes in the nature of the isotropic-to-nematic phase transition as the sample is cooled. The focus of these Monte Carlo simulations is to study the competing effects of the homeotropic anchoring due to the surface inducing orientational ordering in the radial direction and the inherent uniaxial order promoted by the intermolecular interactions. By adopting entropic sampling procedure, we could investigate this transition with a high temperature precision, and we studied the effect of the surface anchoring strength on the phase diagram for a specifically chosen geometry. We find that there is a threshold anchoring strength of the surface below which uniaxial nematic phase results, and above which the isotropic fluid cools to a ...

2010-01-01

478

Light amplification by S/sub 2/ molecules in the visible spectrum under supersonic cooling of a sulfur-containing gas mixture  

Energy Technology Data Exchange (ETDEWEB)

The light gain due to S/sub 2/ molecules in a supersonically cooled gas mixture is calculated. The S/sub 2/ molecules formed due to the recombination of the sulfur atoms, and the combustion gas mixture was preheated in a precombustion chamber. Optimal gas flow and nozzle parameters are found which correspond to the highest possible light gain using Cs/sub 2/-Ar and S/sub 2/-Ar gas mixtures. The steady state gas flow in the nozzle was calculated, taking into account the chemical reactions in the one-dimensional approximation. It is shown that the maximum gain values vary in the 0.0001-0.002 range for gas pressures in the precombustion chamber in the range 10-100 atm. The optimal initial relative concentration of Cs/sub 2/ molecules and S/sub 2/ molecules are given. 32 references.

1985-08-01

479

Joule-Thomson cryogenic cooler with extremely high thermal stability  

Science.gov (United States)

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

1991-06-01

480

Investigation of cool and hot executive function in ODD/CD independently of ADHD  

British Library Electronic Table of Contents (United Kingdom)

Background:- Children with oppositional defiant disorder/conduct disorder (ODD/CD) have shown deficits in -cool- abstract-cognitive, and -hot- reward-related executive function (EF) tasks. However, it is currently unclear to what extent ODD/CD is associated with neuropsychological deficits, independently of attention deficit hyperactivity disorder (ADHD). Methods:- Fifty-nine adolescents with a history of early-onset oppositional problems, 28 with pure ODD/CD symptoms and 31 with ADHD with or without ODD/CD, and 34 healthy controls were administered a task battery measuring motor response inhibition, sustained attention, cognitive flexibility and reward-related decision-making. Findings were analysed using dimensional and group analyses. Results:- In group analyses both groups with and wit...

2011-01-01

481

Integral air-conditioning system for electric cars. Integrales Klimasystem fuer Elektroautomobile  

Energy Technology Data Exchange (ETDEWEB)

Increasing environmental awareness and new legislation in Europe and, in particular, America have accelerated the development of marketable electric cars which satisfy customer demands in terms of performance, range capability, safety and comfort. Tomorrow's electric cars will therefore require powerful heating and cooling systems for the passenger compartment which meet the conditions specific to this particular mode of transport and which do not overly affect the range capability of such vehicles. At Behr GmbH suitable system concepts were developed at a very early stage which were based on a high proportion of recirculated air, the use of the A/C unit as a heat pump, and heat recovery. This paper will examine two typical A/C systems which combine good heating and cooling characteristics with the low electric power requirement of only 1,5-2 kW. (orig.).

1992-11-01

482

Final Report for Award DE-FG02-99ER54554 Kinetics of Electron Fluxes in Low-Pressure Nonthermal Plasmas  

Energy Technology Data Exchange (ETDEWEB)

This grant has focused on the study of several aspects of electron kinetics in low pressure plasmas. Entirely new effects arise from the fact that the electron kinetics is governed by non-local effects, in which the electron distribution function is not equilibrium with the local electric field but is governed by spatial transport effects. In this grant, we were able to demonstrate several previously un-studied effects which are a direct result of the nonlocal transport. These are: (1) The existence of a ''convective cell' in electron phase space. The phenomenon was observed and studied in CW plasma conditions. (2) The occurrence of non-collisional cooling of electrons through an effect known as ''diffusive cooling''.

2004-12-13

483

Dimensioning of the cooling system of the capacitors operating in a high frequency antenna, through a finite element method; Dimensionnement du systeme de refroidissement des condensateurs d'une antenne a haute frequence, par la methode des elements finis  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the study of the heat transfer and of thermal behaviour of the HF (high frequency) components (in fact capacitors) of the ITER-proto-2005-FCI antenna. Preliminary results carried out with the Castem software show that it is possible to cool the hottest part of the antenna efficiently. A water flow (1 bar, 25 Celsius degrees) or an helium flow (10 bars, 50 Celsius degrees) permit to limit the maximal value of the temperature to 270 Celsius degrees. A second software Ansys has allowed the author to simulate capacitors with more complicated shapes. (A.C.)

2003-07-01

484

Corrosion and scale processes and their inhibition in simulated cooling water systems by monosaccharides derivatives  

British Library Electronic Table of Contents (United Kingdom)

A study of the ordinary mild steel/cooling water interface, with and without inhibitor, was carried out using electrochemical impedance spectroscopy (EIS). EIS spectra in uninhibited medium reveal that a layer of corrosion and scale products is formed naturally and evolves with the immersion time. Monosaccharides derivatives were used as corrosion inhibitors. Most of them exhibit good behaviour against corrosion of ordinary steel in simulated water systems. Their inhibiting efficiency increases with concentration rise and depends on molecular structure especially -OH groups' position on two adjacent carbons and their number. In addition, the effect of MoO4^2^- on the corrosion inhibition in the presence of the best inhibitor was also studied by EIS. The addition of MoO4^2^- enhanced the in...

2009-01-01

485

Causes of denting. Volume 1. Summary report. Final report  

Science.gov (United States)

This summary report outlines the work that was performed to gain a more complete understanding of denting corrosion of steam generators in PWRs. Background laboratory and plant data on denting were compiled, reviewed and correlated to determine how various exposure conditions affect denting. Two high-temperature chemistry analytical models were reviewed and evaluated by experimental simulation of impurity concentration in the heat transfer and isothermal capsule tests. Simulation of impurity concentration for three cooling waters (lake, river, and cooling tower) was evaluated. The effects of species concentration (Cu/sup + +/, Cl/sup -/, O/sub 2/, and H/sup +/), contaminant thresholds (established by isothermal and heat transfer tests), and heat flux as indicated by superheat on denting were examined. A discussion of several pertinent observations and conclusions drawn from these tasks (as they pertain to plant operation) is presented.

1984-05-01

486

Averting problems caused by solutions  

International Nuclear Information System (INIS)

A brief overview is given of a report on Emergency Core Cooling Systems (ECCS) Recirculation Reliability Knowledge Base compiled by the International Working Group on ECCS Reliability for the OECD/NEA/CSNI. Four safety issues are identified which arise in the context of loss of coolant accidents (LOCAs) and are connected with materials and/or processes that interfere with the ECCS safety function in ways other than just strainer head loss generation. They are: the generation of missiles during a LOCA from encapsulated insulation materials used to reduce insulation debris production; clogging of BWR pressure suppression containment vent pipes by insulation jackets or metallic insulation foil pieces; strainer or sump debris ingestion and the effects of ingested debris on ECCS equipment and core cooling; miscellaneous items such as material aging and self-cleaning strainer concepts. The emphasis is mainly on BWRs but many of the considerations ...

487

AquaMagna Water Conditioner and Descaler  

Wastenet

...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...

488

Apparatus for in situ determination of burnup cooling time and fissile content of an irradiated nuclear fuel assembly in a fuel storage pond  

Energy Technology Data Exchange (ETDEWEB)

A detector head for in situ inspection of irradiated nuclear fuel assemblies submerged in a water-filled nuclear fuel storage pond. The detector head includes two parallel arms which extend from a housing and which are spaced apart so as to be positionable on opposite sides of a submerged fuel assembly. Each arm includes an ionization chamber and two fission chambers. One fission chamber in each arm is enclosed in a cadmium shield and the other fission chamber is unshielded. The ratio of the outputs of the shielded and unshielded fission chambers is used to determine the boron content of the pond water. Correcting for the boron content, the neutron flux and gamma ray intensity are then used to verify the declared exposure, cooling time and fissile material content of the irradiated fuel assembly.

1985-04-09

489

A study on the cooling effects of greening in a high-density city: An experience from Hong Kong  

British Library Electronic Table of Contents (United Kingdom)

Greening is a useful mitigation strategy for planners mainly from a visual perspective. For high-density urban living environment such as Hong Kong, urban greening helps cooling the air and providing shade; it also helps lowering building energy consumption by providing a better outdoor boundary condition. Many researchers have also suggested that greening may be employed as a strategy for combating the ill effects of urban Heat Island (UHI). Working towards a set of better greening guidelines for urban planners, the current paper first provides a comprehensive review of planning with urban greening. It then describes parametric studies that have been conducted to investigate the preferred location, amount, and types of vegetation for urban planning. The parametric studies employed the num...

2012-01-01

490

A He-gas Cooled, Stationary Granular Target  

CERN Document Server

In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.

2003-01-01

491

Steel microstructure engineering for large diameter tubes; Engenharia de microestrutura de acos para tubos de grande diametro  

Energy Technology Data Exchange (ETDEWEB)

High and ultra-high strength steels for pipelines are produced by properly handling the steel microstructure. The metallurgical principles involved in the microstructure control are presented, with emphasis on TMCP processing, that comprises conventional controlled rolling followed by accelerated cooling. (author)

2008-05-15

492

New safety device announced for nuclear power plants  

International Nuclear Information System (INIS)

An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.

493

Method of controlling the coolant level in the cooling system of a nuclear power plant  

International Nuclear Information System (INIS)

Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).

494

Lifting the lid off the Windscale AGR  

Energy Technology Data Exchange (ETDEWEB)

With the lifting of the top dome of the Windscale (AGR) Advanced Gas-cooled Reactor earlier this year, the decommissioning team has begun to dismantle the heaviest of the reactor components. In defining the tasks involved, the most important criterion was to minimise the radiation exposure expected to be received by the team members. The manager of the WAGR decommissioning project describes the preparation undertaken and the final lifting of the top dome in this article. (author).

1991-10-01

495

Lamp system for uniform semiconductor wafer heating  

Energy Technology Data Exchange (ETDEWEB)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

2001-01-01

496

Innovative clean gas introduction into new cooling tower packing; Innovative Reingaseinleitung in Kuehlturmneubauten  

Energy Technology Data Exchange (ETDEWEB)

In 1991/1992, VEAG decided to convert its 500 MW plants at Jaenschwalde and Boxberg to the latest state of technology. This even included the discharge of the cleaned flue gas through the existing cooling towers. The site of the flue gas desulphurization plant and also the existing cooling tower shells required routeing of the clean gas lines similar to the routes in the existing plants of RWE. The positive experience accrued with the pipework material `glass-fibre reinforced vinyl ester resin` has also led to the selection of this material here. The universally positive experience gained from existing clean gas lines via cooling towers by very different power station operators induced VEAG and its partners also to equip new construction operations in the new Federal states with this technology. (orig.) [Deutsch] In den Jahren 1991/1992 entschloss sich die VEAG, ihre 500-MW-Anlagen Jaenschwalde und Boxberg auf den neuesten ...

1997-06-01

497

Effect of the PVC system?s topology on the dielectric losses in the region of strong electric fields  

British Library Electronic Table of Contents (United Kingdom)

The electrophysical characteristics of the electric cable?s transition into a state of a heterogenic polymer system due to a wire?s explosion were examined. Using cyclic heating-cooling of the composite, the changes in its topology were observed. The latter makes it possible to regulate the dielectric characteristics of the system.

2011-01-01

498

EVOLUTION OF WHITE DWARF STARS WITH HIGH-METALLICITY PROGENITORS: THE ROLE OF "2"2Ne DIFFUSION  

International Nuclear Information System (INIS)

Motivated by the strong discrepancy between the main-sequence turnoff age and the white dwarf cooling age in the metal-rich open cluster NGC 6791, we compute a grid of white dwarf evolutionary sequences that incorporates for the first time the energy released by the processes of "2"2Ne sedimentation and of carbon/oxygen phase separation upon crystallization. The grid covers the mass range from 0.52 to 1.0 M _s_u_n, and is appropriate for the study of white dwarfs in metal-rich clusters. The evolutionary calculations are based on a detailed and self-consistent treatment of the energy released from these two processes, as well as on the employment of realistic carbon/oxygen profiles, of relevance for an accurate evaluation of the energy released by carbon/oxygen phase separation. We find that "2"2Ne sedimentation strongly delays the cooling rate of white dwarfs stemming from progenitors with high metallicities at moderate luminosities, while ...

2010-08-10

499

Design and fabrication of a traveling-wave muffin-tin accelerating structure at 90 GHz  

Energy Technology Data Exchange (ETDEWEB)

A prototype of a muffin-tin accelerating structure operating at 32 times the SLAC frequency (2.856 GHz) was built for research in high gradient acceleration. A traveling-wave design with single input and output feeds was chosen for the prototype which was fabricated by wire electrodischarge machining. Features of the mechanical design for the prototype are described. Design improvements are presented including considerations of cooling and vacuum.

1997-05-01